Initial call of this OB Events discarded
Optimized Diagnostics 30 FBD CyclicInterrupt false cs-CZ de-DE en-US FBD cs-CZ de-DE Calling "ReadServerDiagnostics" to read diagnostic information from Server object elements of the own OPC UA Server of the PLC. en-US Calling "ReadServerDiagnostics" to read diagnostic information from Server object elements of the own OPC UA Server of the PLC. cs-CZ de-DE Read Server Diagnostics en-US Read Server Diagnostics true true true true true true true true true SCL cs-CZ de-DE en-US cs-CZ de-DE Pass return values to global DB for display en-US Pass return values to global DB for display FBD cs-CZ de-DE Calling "ReadSessionDisgnostics" to read out Session-specific information of the own OPC UA Server of the PLC. The NodeId of the specific SessionDiagnostics is determined by searching for an active client session name containing the sepcified "sessionNameSubstring". The input parameter "NodeIdExtension" allows to address subelements of a "SessionDiagnostics" and is left empty here to address the top node. A rising edge at the "read" input triggers a single read execution. en-US Calling "ReadSessionDisgnostics" to read out Session-specific information of the own OPC UA Server of the PLC. The NodeId of the specific SessionDiagnostics is determined by searching for an active client session name containing the sepcified "sessionNameSubstring". The input parameter "NodeIdExtension" allows to address subelements of a "SessionDiagnostics" and is left empty here to address the top node. A rising edge at the "read" input triggers a single read execution. cs-CZ de-DE Read Session Diagnostics en-US Read Session Diagnostics true true true true true true true true true true true SCL cs-CZ de-DE en-US cs-CZ de-DE Pass return values to global DB for display en-US Pass return values to global DB for display FBD cs-CZ de-DE Calling "ReadSessionDisgnostics" to read out session-specific node "ClientLastContactTime" of the own OPC UA Server of the PLC. The NodeId of a specific "SessionDiagnostics" is determined by searching for an active client session name containing the sepcified "sessionNameSubstring". The input parameter "NodeIdExtension" allows to address subelements of a "SessionDiagnostics" variable because the NodeId is simply extended with the name of the data point, e.g. "Session_XY.ClientLastContactTime". The input "enable" activates a repeated read access (polling). "CheckForTimeOut" compares the "ClientLastContactTime" and sets "isTimedOut" if the treshhold "timeOut" is exceeded. en-US Calling "ReadSessionDisgnostics" to read out session-specific node "ClientLastContactTime" of the own OPC UA Server of the PLC. The NodeId of a specific "SessionDiagnostics" is determined by searching for an active client session name containing the sepcified "sessionNameSubstring". The input parameter "NodeIdExtension" allows to address subelements of a "SessionDiagnostics" variable because the NodeId is simply extended with the name of the data point, e.g. "Session_XY.ClientLastContactTime". The input "enable" activates a repeated read access (polling). "CheckForTimeOut" compares the "ClientLastContactTime" and sets "isTimedOut" if the treshhold "timeOut" is exceeded. cs-CZ de-DE en-US Read Session Diagnostics - ClientLastContactTime true true TRUE Alle 30 sekunden Server Diagnose aktualisieren true true true FALSE Rücksetzen wenn Baustein fertig true true 0 Enable true 0 Init true FALSE true true 3 true TRUE 1 Active true TRUE true true true 2 2 Reenable after timeout true FALSE true true 3 3 Wait true TRUE true true 1 true true 2 T#10s true true 3 T#3s true true T#30s true SCL cs-CZ de-DE en-US cs-CZ de-DE en-US cs-CZ de-DE en-US