diff --git a/bin/activate_venv.bat b/bin/activate_venv.bat new file mode 100644 index 0000000..2119d3f --- /dev/null +++ b/bin/activate_venv.bat @@ -0,0 +1,20 @@ +@echo off +REM ================================================================ +REM HundM_Fortna - Python Virtual Environment aktivieren +REM ================================================================ + +call "%~dp0setenv.bat" + +if not exist "%PROJECT%\.venv" ( + echo FEHLER: Virtual environment nicht gefunden. + echo Bitte zuerst bin\install_py.bat ausfuehren. + exit /b 1 +) + +call "%PROJECT%\.venv\Scripts\activate.bat" +echo Virtuelle Umgebung aktiviert. +echo Python-Version: +python --version +echo. +echo Installierte Pakete: +pip list diff --git a/bin/create_dxf.bat b/bin/create_dxf.bat new file mode 100644 index 0000000..f48caa7 --- /dev/null +++ b/bin/create_dxf.bat @@ -0,0 +1,22 @@ +@echo off +REM ================================================================ +REM HundM_Fortna - DXF-Uebersicht der TROs erzeugen +REM +REM Liest die Skeleton-Dateien (%PV_RESULTS%\skeleton_UH0x.json) und +REM erzeugt %PV_RESULTS%\ST500592_TROs.dxf (TRO-Kaesten als Bloecke, +REM Sensoren als Kreise mit Verbindungslinien) fuer AutoCAD/BricsCAD. +REM ================================================================ + +call "%~dp0setenv.bat" + +REM .venv bevorzugen, sonst System-Python +set "PYTHON=python" +if exist "%PROJECT%\.venv\Scripts\python.exe" ( + set "PYTHON=%PROJECT%\.venv\Scripts\python.exe" +) + +"%PYTHON%" "%PV_LIB%\create_dxf.py" %* +if errorlevel 1 ( + echo FEHLER: create_dxf.py wurde mit Fehler beendet. + exit /b 1 +) diff --git a/bin/create_skel.bat b/bin/create_skel.bat new file mode 100644 index 0000000..637d7a3 --- /dev/null +++ b/bin/create_skel.bat @@ -0,0 +1,22 @@ +@echo off +REM ================================================================ +REM HundM_Fortna - Skeleton-Generator aufrufen +REM +REM Liest die Eingabelisten (%PV_DATA%) und erzeugt je Steuerung +REM ein Skeleton der JSON-Zwischendatei sowie ein SCL-Grundgeruest +REM nach %PV_RESULTS%. +REM ================================================================ + +call "%~dp0setenv.bat" + +REM .venv bevorzugen, sonst System-Python +set "PYTHON=python" +if exist "%PROJECT%\.venv\Scripts\python.exe" ( + set "PYTHON=%PROJECT%\.venv\Scripts\python.exe" +) + +"%PYTHON%" "%PV_LIB%\create_skel.py" %* +if errorlevel 1 ( + echo FEHLER: create_skel.py wurde mit Fehler beendet. + exit /b 1 +) diff --git a/bin/generate_tro_graph.bat b/bin/generate_tro_graph.bat new file mode 100644 index 0000000..306d17c --- /dev/null +++ b/bin/generate_tro_graph.bat @@ -0,0 +1,41 @@ +@echo off +REM Erzeugt den TRO-Topologie-Graphen (DOT) aus den FB_Main.scl-Dateien +REM und rendert ihn anschliessend mit Graphviz als SVG. +REM +REM Voraussetzung: Graphviz (dot.exe) muss installiert sein, z.B. per +REM winget install --id Graphviz.Graphviz -e + +setlocal +set "SCRIPT_DIR=%~dp0" +set "REPO_DIR=%SCRIPT_DIR%.." +set "DOT_FILE=%REPO_DIR%\doc\TRO_Graph_UH01-UH05.dot" +set "SVG_FILE=%REPO_DIR%\doc\TRO_Graph_UH01-UH05.svg" + +echo Erzeuge %DOT_FILE% ... +python "%SCRIPT_DIR%generate_tro_graph.py" "%DOT_FILE%" +if errorlevel 1 ( + echo Fehler bei der Erzeugung der DOT-Datei. + exit /b 1 +) + +set "DOT_EXE=dot" +where %DOT_EXE% >nul 2>nul +if errorlevel 1 ( + if exist "C:\Program Files\Graphviz\bin\dot.exe" ( + set "DOT_EXE=C:\Program Files\Graphviz\bin\dot.exe" + ) else ( + echo dot.exe wurde nicht gefunden. Bitte Graphviz installieren: + echo winget install --id Graphviz.Graphviz -e + exit /b 1 + ) +) + +echo Rendere %SVG_FILE% ... +"%DOT_EXE%" -Tsvg "%DOT_FILE%" -o "%SVG_FILE%" +if errorlevel 1 ( + echo Fehler beim Rendern der SVG-Datei. + exit /b 1 +) + +echo Fertig: %SVG_FILE% +endlocal diff --git a/bin/generate_tro_graph.py b/bin/generate_tro_graph.py new file mode 100644 index 0000000..548ebc4 --- /dev/null +++ b/bin/generate_tro_graph.py @@ -0,0 +1,325 @@ +# -*- coding: utf-8 -*- +"""Extrahiert den TRO-Topologie-Graphen aller 5 UH-Steuerungen aus FB_Main.scl +und erzeugt eine Graphviz-DOT-Datei. + +Prinzip: Jeder TRO-Baustein bekommt JamArea-Slots als Parameter +(arInOutJamEntr*, arInOutJamExit*, arInOutJamBypass, arInOutJamFinger). +Zwei TROs sind verbunden, wenn der Exit-Slot des einen dieselbe JamArea +referenziert wie der Entry-Slot des anderen. + +Aufruf: + python bin/generate_tro_graph.py [ausgabe.dot] + +Ohne Argument wird nach doc/TRO_Graph_UH01-UH05.dot geschrieben. +Zum Rendern als SVG anschliessend: + dot -Tsvg doc/TRO_Graph_UH01-UH05.dot -o doc/TRO_Graph_UH01-UH05.svg +""" +import re +import sys +from collections import defaultdict +from pathlib import Path + +REPO = Path(__file__).resolve().parent.parent +UHS = ["UH01", "UH02", "UH03", "UH04", "UH05"] + +decl_re = re.compile(r'^\s*(\w+)\s*(?:\{[^}]*\})?\s*:\s*"([\w.]+)"\s*;') +jamparam_re = re.compile( + r'arInOut(Jam\w+|StorageLines|CarrierStopper|CarrierExit)' + r'\s*:=\s*"([^"]+)"\.(\w+)') +call_start_re = re.compile(r'#(\w+)\s*\(') +region_re = re.compile(r'^\s*REGION\b\s*(.*)$') +endregion_re = re.compile(r'^\s*END_REGION') + + +def parse_uh(uh): + path = REPO / f"=A01+{uh}-KF00" / "Programmbausteine" / "100_Main" / "FB_Main.scl" + text = path.read_text(encoding="utf-8-sig") + text = re.sub(r'\(\*.*?\*\)', '', text, flags=re.S) # Blockkommentare + lines = [re.sub(r'//.*$', '', ln) for ln in text.splitlines()] + + # 1) Instanz-Deklarationen -> FB-Typ + types = {} + for ln in lines: + m = decl_re.match(ln) + if m: + types[m.group(1)] = m.group(2) + + # 2) Aufrufe finden inkl. REGION-Kontext + nodes = {} # inst -> dict(type, region, jams=[(role, jamref)]) + region_stack = [] + i = 0 + while i < len(lines): + ln = lines[i] + if endregion_re.match(ln): + if region_stack: + region_stack.pop() + i += 1 + continue + m = region_re.match(ln) + if m and "END_REGION" not in ln.split("REGION")[0]: + region_stack.append(m.group(1).strip()) + i += 1 + continue + m = call_start_re.search(ln) + if m and types.get(m.group(1)): + inst = m.group(1) + # Parameterblock bis zur schliessenden Klammer einsammeln + buf = ln[m.end() - 1:] + depth = 0 + j = i + done = False + while j < len(lines) and not done: + seg = lines[j] if j > i else buf + for ch in seg: + if ch == "(": + depth += 1 + elif ch == ")": + depth -= 1 + if depth == 0: + done = True + break + j += 1 + block = "\n".join([buf] + lines[i + 1:j]) + jams = [] + for jm in jamparam_re.finditer(block): + role, db, member = jm.group(1), jm.group(2), jm.group(3) + jams.append((role, f"{db}.{member}")) + if jams: + # aussagekraeftigste REGION waehlen (generische wie "CALL", + # "TRO 101 CALL", "Enable und RequestRun" ueberspringen) + region = "" + for r in reversed(region_stack): + if not re.match(r'^(.*\bCALL\b.*|Enable und RequestRun)$', + r, re.I): + region = r + break + node = nodes.setdefault(inst, { + "type": types[inst], + "region": region, + "jams": []}) + for j2 in jams: + if j2 not in node["jams"]: + node["jams"].append(j2) + i = j + continue + i += 1 + return nodes + + +def role_dir(role): + if role.startswith("JamEntr") or role in ("StorageLines", + "CarrierStopper"): + return "in" + if (role.startswith(("JamExit", "JamBypass", "JamFinger")) + or role == "CarrierExit"): + return "out" + return "?" + + +def short_jam(jamref): + # DB_JamArea0101.stJam0101_1 -> JA0101_1 + m = re.match(r"DB_JamArea(\w+)\.stJam\w+_(\w+)", jamref) + if m: + return f"JA{m.group(1)}_{m.group(2)}" + return jamref.replace("DB_", "").replace(".arLine", "") + + +def main(): + all_nodes = {} + report = [] + for uh in UHS: + nodes = parse_uh(uh) + all_nodes[uh] = nodes + report.append(f"{uh}: {len(nodes)} TRO-Knoten") + + # Kanten je UH ueber gemeinsame JamAreas + edges = defaultdict(list) # uh -> [(from, to, jam, tag)] + externals = defaultdict(list) # uh -> [(node, dir, jam, role)] + for uh, nodes in all_nodes.items(): + jam_users = defaultdict(lambda: {"in": [], "out": []}) + for inst, nd in nodes.items(): + for role, jam in nd["jams"]: + d = role_dir(role) + if d in ("in", "out"): + jam_users[jam][d].append((inst, role)) + for jam, users in sorted(jam_users.items()): + for (src, srole) in users["out"]: + tag = {"JamExit3": "Dir2", "JamExit4": "Dir3", + "JamBypass": "Bypass", "JamFinger": "Finger" + }.get(srole, "") + if users["in"]: + for (dst, drole) in users["in"]: + if dst != src: + edges[uh].append((src, dst, jam, tag)) + else: + externals[uh].append((src, "out", jam, srole)) + for (dst, drole) in users["in"]: + if not users["out"]: + externals[uh].append((dst, "in", jam, drole)) + + for uh in UHS: + report.append(f"{uh}: {len(edges[uh])} Kanten, " + f"{len(externals[uh])} offene Enden") + print("\n".join(report)) + + # Knoten ohne jede Kante? + for uh, nodes in all_nodes.items(): + connected = set() + for (s, d, _, _) in edges[uh]: + connected.add(s) + connected.add(d) + for (n, _, _, _) in externals[uh]: + connected.add(n) + iso = set(nodes) - connected + if iso: + print(f"{uh} isoliert: {sorted(iso)}") + + write_dot(all_nodes, edges, externals) + + +COLORS = { + "FB_ILS_MTRO_1Sep": ("#d4e8ff", "box"), + "FB_ILS_MTRO_1Sep_SSCC": ("#ffd4d4", "box"), + "FB_ILS_MTRO_1Sep1Swi": ("#ffe4a0", "diamond"), + "FB_ILS_MTRO_1Sep2Swi": ("#ffc060", "diamond"), + "FB_ILS_MTRO_2Sep1Swi": ("#ffe4a0", "diamond"), + "FB_ILS_MTRO_Vario": ("#e8d4f0", "parallelogram"), + "FB_ILS_MTRO_Vario_workStation": ("#c0f0f0", "parallelogram"), + "FB_EmptyCarrBuffer": ("#d4f0d4", "box3d"), +} + + +def node_style(fbtype): + for k in sorted(COLORS, key=len, reverse=True): + if fbtype.startswith(k): + return COLORS[k] + return ("#f0f0f0", "box") + + +def esc(s): + return s.replace("\\", "\\\\").replace('"', '\\"') + + +HEADER = '''\ +// ============================================================================ +// TRO-Topologie-Graph der Gesamtanlage HundM_Fortna (UH01 - UH05) +// ============================================================================ +// +// Format: Graphviz DOT (https://graphviz.org) +// Rendern z.B. mit: dot -Tsvg TRO_Graph_UH01-UH05.dot -o graph.svg +// oder online: https://dreampuf.github.io/GraphvizOnline +// +// Quelle: Automatisch extrahiert aus den FB_Main.scl der 5 Steuerungen +// (=A01+UH01-KF00 ... =A01+UH05-KF00, Ordner 100_Main). +// Erzeugt von bin/generate_tro_graph.py. +// +// Methode: Jeder TRO-Baustein (FB_ILS_MTRO_*, FB_EmptyCarrBuffer, +// FB_LoadingBoom_INBOUND) referenziert JamAreas als Parameter: +// arInOutJamEntr* / arInOutStorageLines / arInOutCarrierStopper = Eingang +// arInOutJamExit* / arInOutJamBypass / arInOutJamFinger / +// arInOutCarrierExit = Ausgang +// Zwei TROs sind verbunden, wenn der Ausgangs-Slot des einen +// dieselbe JamArea referenziert wie der Eingangs-Slot des anderen. +// Auskommentierter Code wurde ignoriert. +// +// Knoten: Ein Knoten je TRO-Instanz, Label: Name, [FB-Typ], REGION-Kommentar +// aus FB_Main. Farbe/Form nach FB-Typ: +// hellblau/Box = 1Sep (Standard-Separator) +// rot/Box = 1Sep_SSCC (SSCC-Scanner + WCS-Telegramm) +// gelb/Raute = 1Sep1Swi, 1Sep2Swi, 2Sep1Swi (Weichen) +// violett/Parallelogr.= Vario (Kettenfoerderer) +// tuerkis/Parallelogr.= Vario_workStation (manueller Arbeitsplatz) +// gruen/3D-Box = EmptyCarrBuffer (Leertablar-Puffer) +// grau = Sonstige (z.B. LoadingBoom, PinStore) +// +// Kanten: Label = JamArea-Slot (JAxxxx_y = "DB_JamAreaxxxx".stJamxxxx_y). +// Zusatz "Dir2"/"Dir3" = Weichen-Ausgang (arInOutJamExit3/4), +// Richtungsentscheidung kommt aus FC_Direction. +// Gestrichelt "Bypass" = Bypass-Spur (PinStore), +// gestrichelt "Finger" = Finger-Uebergabe eines Vario-Foerderers. +// +// EXTERN: Graue Kanten zu EXTERN-Knoten = JamAreas, die nur auf einer +// Seite belegt sind (Anlagengrenze, Uebergabe an WES/WCS, AMR +// oder andere SPS). CPU-CPU-Uebergaben zwischen den Steuerungen +// sind an den Labels "IO_Device_UHxx_TO_UHyy..." erkennbar +// (PROFINET-Direktkopplung, kein gemeinsamer JamArea-DB). +// +// Hinweis: Kanten existieren nur innerhalb einer Steuerung, da JamArea-DBs +// nicht SPS-uebergreifend geteilt werden. Der physische Fluss +// zwischen den UHs laeuft ueber die EXTERN-Uebergaben. +// +''' + + +def write_dot(all_nodes, edges, externals): + body = [] + B = body.append + B(HEADER.rstrip()) + total_n = sum(len(v) for v in all_nodes.values()) + total_e = sum(len(set(v)) for v in edges.values()) + B(f"// Umfang: {total_n} TRO-Knoten, {total_e} Verbindungen " + f"(Stand der Extraktion siehe Git-Historie)") + for uh in UHS: + B(f"// {uh}: {len(all_nodes[uh])} TROs, " + f"{len(set(edges[uh]))} Verbindungen") + B("") + B("digraph TRO_Topologie {") + B(' rankdir = "LR";') + B(' fontname = "Arial";') + B(' node [fontname="Arial", fontsize=10];') + B(' edge [fontname="Arial", fontsize=8];') + B(' label = "TRO-Topologie HundM_Fortna (UH01-UH05)";') + B(' labelloc = "t";') + B("") + for uh in UHS: + nodes = all_nodes[uh] + B(f' subgraph "cluster_{uh}" {{') + B(f' label = "{uh} (=A01+{uh}-KF00)";') + B(' style = "rounded";') + B(' color = "#888888";') + for inst in sorted(nodes): + nd = nodes[inst] + color, shape = node_style(nd["type"]) + t = nd["type"].replace("FB_ILS_MTRO_", "").replace("FB_", "") + reg = esc(nd["region"]) + B(f' "{uh}.{inst}" [label="{inst}\\n[{t}]\\n{reg}", ' + f'shape={shape}, style=filled, fillcolor="{color}"];') + # Externe Enden als ein Sammel-Knoten je Richtung + ext = externals[uh] + if any(d == "in" for (_, d, _, _) in ext): + B(f' "{uh}.EXTERN_IN" [label="EXTERN\\n(Zulauf)", ' + f'shape=ellipse, style="filled,dashed", fillcolor="#f8f8f8"];') + if any(d == "out" for (_, d, _, _) in ext): + B(f' "{uh}.EXTERN_OUT" [label="EXTERN\\n(Ablauf)", ' + f'shape=ellipse, style="filled,dashed", fillcolor="#f8f8f8"];') + seen = set() + for (s, d, jam, tag) in edges[uh]: + key = (s, d, jam, tag) + if key in seen: + continue + seen.add(key) + lbl = short_jam(jam) + (f" {tag}" if tag else "") + style = ', style=dashed' if tag in ("Bypass", "Finger") else "" + B(f' "{uh}.{s}" -> "{uh}.{d}" [label="{lbl}"{style}];') + seen = set() + for (n, d, jam, role) in ext: + key = (n, d, jam) + if key in seen: + continue + seen.add(key) + if d == "in": + B(f' "{uh}.EXTERN_IN" -> "{uh}.{n}" ' + f'[label="{short_jam(jam)}", color="#999999"];') + else: + B(f' "{uh}.{n}" -> "{uh}.EXTERN_OUT" ' + f'[label="{short_jam(jam)}", color="#999999"];') + B(" }") + B("") + B("}") + dest = Path(sys.argv[1]) if len(sys.argv) > 1 else REPO / "doc" / "TRO_Graph_UH01-UH05.dot" + dest.write_text("\n".join(body) + "\n", encoding="utf-8", newline="\n") + print("DOT geschrieben:", dest) + + +if __name__ == "__main__": + main() diff --git a/bin/get_cmd.bat b/bin/get_cmd.bat new file mode 100644 index 0000000..0699d98 --- /dev/null +++ b/bin/get_cmd.bat @@ -0,0 +1,7 @@ +@echo off +REM ================================================================ +REM HundM_Fortna - Shell mit gesetzten Umgebungsvariablen oeffnen +REM ================================================================ + +call "%~dp0setenv.bat" +start cmd /k "echo HundM_Fortna Umgebung aktiv. && echo PROJECT=%PROJECT%" diff --git a/bin/install_py.bat b/bin/install_py.bat new file mode 100644 index 0000000..54d7d5d --- /dev/null +++ b/bin/install_py.bat @@ -0,0 +1,21 @@ +@echo off +REM ================================================================ +REM HundM_Fortna - Python Virtual Environment einrichten +REM ================================================================ + +call "%~dp0setenv.bat" + +if not exist "%PROJECT%\.venv" ( + echo Initialisiere Python virtual environment... + py -m venv "%PROJECT%\.venv" --upgrade-deps + echo Erfolgreich. + + call "%PROJECT%\.venv\Scripts\activate.bat" + echo Installiere erforderliche Python Packages... + pip install -r "%PROJECT%\requirements.txt" -q + echo Erfolgreich. + deactivate +) else ( + echo .venv existiert bereits - Abbruch. + echo Zum Neuaufsetzen .venv loeschen und install_py.bat erneut ausfuehren. +) diff --git a/bin/setenv.bat b/bin/setenv.bat new file mode 100644 index 0000000..bc9f434 --- /dev/null +++ b/bin/setenv.bat @@ -0,0 +1,62 @@ +@echo off +REM ================================================================ +REM HundM_Fortna - Umgebungsvariablen Setup +REM ================================================================ + +echo Setting up environment variables for HundM_Fortna ... + +REM Basis-Projektpfad (Elternordner von bin\) +set "PROJECT=%~dp0.." +if "%PROJECT:~-6%"=="bin\.." set "PROJECT=%PROJECT:~0,-6%" +if "%PROJECT:~-1%"=="\" set "PROJECT=%PROJECT:~0,-1%" + +REM Pfade fuer die Komponenten +set "PV_BIN=%PROJECT%\bin" +set "PV_LIB=%PROJECT%\lib" +set "PV_CFG=%PROJECT%\cfg" +set "PV_DATA=%PROJECT%\data" +set "PV_DOC=%PROJECT%\doc" +set "PV_LOG=%PROJECT%\log" +set "PV_RESULTS=%PROJECT%\results" +set "PV_EXAMPLES=%PROJECT%\examples" +set "PV_TESTS=%PROJECT%\tests" + +REM PYTHONPATH um PV_LIB erweitern (nur wenn noch nicht enthalten) +if not defined PYTHONPATH ( + set "PYTHONPATH=%PV_LIB%" +) else ( + echo.%PYTHONPATH% | find /i "%PV_LIB%" >nul || set "PYTHONPATH=%PYTHONPATH%;%PV_LIB%" +) + +REM Ueberladen von Umgebungsvariablen durch _setenv.bat +REM (z.B. PV_DATA auf einen Netzlaufwerk-Pfad umbiegen) +if exist "%~dp0_setenv.bat" ( + echo Lade lokale Umgebungseinstellungen aus _setenv.bat... + call "%~dp0_setenv.bat" +) + +REM Ordner erstellen falls sie nicht existieren +if not exist "%PV_BIN%" mkdir "%PV_BIN%" +if not exist "%PV_LIB%" mkdir "%PV_LIB%" +if not exist "%PV_CFG%" mkdir "%PV_CFG%" +if not exist "%PV_DATA%" mkdir "%PV_DATA%" +if not exist "%PV_LOG%" mkdir "%PV_LOG%" +if not exist "%PV_RESULTS%" mkdir "%PV_RESULTS%" +if not exist "%PV_EXAMPLES%" mkdir "%PV_EXAMPLES%" +if not exist "%PV_TESTS%" mkdir "%PV_TESTS%" + +REM Umgebungsvariablen anzeigen +echo. +echo ================================================================ +echo PROJECT = %PROJECT% +echo PV_BIN = %PV_BIN% +echo PV_LIB = %PV_LIB% +echo PV_CFG = %PV_CFG% +echo PV_DATA = %PV_DATA% +echo PV_LOG = %PV_LOG% +echo PV_RESULTS = %PV_RESULTS% +echo PV_EXAMPLES = %PV_EXAMPLES% +echo PV_TESTS = %PV_TESTS% +echo PYTHONPATH = %PYTHONPATH% +echo ================================================================ +echo. diff --git a/cfg/skel.cfg b/cfg/skel.cfg new file mode 100644 index 0000000..d2195ff --- /dev/null +++ b/cfg/skel.cfg @@ -0,0 +1,146 @@ +{ + "files": { + "tia_xlsx": "ST500592_10_5-14_ILS-{n}_TIA.xlsx", + "positions_json": "ST500592_10_5-9_ILS_positions.json", + "connect_json": "connect.json", + "connect_ini": "connect.ini" + }, + "verw_roles": { + "In sep": "sensorInSep", + "Sep": "stopperOutput", + "Jam detector": "sensorJam", + "Jam detector (LP)": "sensorJam", + "jam detector (LP)": "sensorJam", + "ES branch": "switchOutput", + "ES brunch": "switchOutput", + "conveyor full": "sensorConvFull", + "MT in Position": "sensorCarrInPos", + "MT in position": "sensorCarrInPos", + "Finger in position": "sensorFinger", + "Finger in Position": "sensorFinger", + "PIN query": "sensorPinQuery", + "Rad dreht ": "sensorWheel", + "Rad dreht": "sensorWheel" + }, + "comment_roles": [ + [ + "^in Separator", + "sensorInSep" + ], + [ + "^Separator", + "stopperOutput" + ], + [ + "Stausensor|Staumelder", + "sensorJam" + ], + [ + "AE Abzweig", + "switchOutput" + ], + [ + "F.?rderer voll", + "sensorConvFull" + ], + [ + "MT in Position", + "sensorCarrInPos" + ], + [ + "Mitnehmerfinger|Finger in", + "sensorFinger" + ], + [ + "Pin Abfrage|Pr.?fung MT Pos", + "sensorPinQuery" + ], + [ + "Rad dreht", + "sensorWheel" + ], + [ + "^Motor ", + "motorOutput" + ], + [ + "MSS ausgel", + "motorProtection" + ] + ], + "fbtype_rules": [ + { + "roles": [ + "sensorPinQuery" + ], + "fbType": "FB_ILS_MTRO_PinStore_Auto" + }, + { + "roles": [ + "sensorFinger" + ], + "fbType": "FB_ILS_MTRO_Vario" + }, + { + "roles": [ + "sensorCarrInPos" + ], + "fbType": "FB_ILS_MTRO_Vario" + }, + { + "roles": [ + "switchOutput", + "sensorInSep" + ], + "fbType": "FB_ILS_MTRO_1Sep1Swi" + }, + { + "roles": [ + "sensorInSep" + ], + "fbType": "FB_ILS_MTRO_1Sep" + }, + { + "roles": [ + "motorOutput" + ], + "fbType": "FB_Conveyor" + }, + { + "roles": [ + "motorProtection" + ], + "fbType": "FB_Conveyor" + } + ], + "unit_re": "\\b(KR|CV)[-\\s]{0,2}(P?[MK]\\d{4}(?:_[A-Z])?)\\b", + "area_res": [ + [ + "Block ?(\\d\\.\\d(?:\\.\\d)?)", + "pinStoreBlock", + "Block {m}" + ], + [ + "\\bLS ?(\\d)\\b", + "loadingStation", + "LS{m}" + ], + [ + "\\bWS ?(\\d\\.\\d)\\b", + "workStation", + "WS{m}" + ], + [ + "\\bUZ(\\d{4})\\b", + "safetyZone", + "UZ{m}" + ] + ], + "fbtype_template": { + "FB_ILS_MTRO_1Sep": "call_1sep", + "FB_ILS_MTRO_1Sep1Swi": "call_1sep1swi", + "FB_ILS_MTRO_Vario": "call_vario", + "FB_ILS_MTRO_PinStore_Auto": "call_1sep", + "FB_Conveyor": "call_conveyor" + } +} diff --git a/cfg/skel_scl.cfg b/cfg/skel_scl.cfg new file mode 100644 index 0000000..2e45dbc --- /dev/null +++ b/cfg/skel_scl.cfg @@ -0,0 +1,142 @@ +; ================================================================ +; skel_scl.cfg — SCL-Templates fuer create_skel.py (INI-Style) +; +; Jede [sektion] ist ein Template; der Inhalt wird VERBATIM +; uebernommen (Einrueckung und Leerzeilen gehoeren zum Template, +; auch Leerzeilen am Blockende!). Zeilen, die mit ';' beginnen, +; sind Kommentare und werden ueberall ignoriert. +; Platzhalter im str.format()-Stil: {inst}, {tro_no}, {stopper} ... +; geschweifte Klammern im SCL selbst als {{ }} doppeln. +; ================================================================ +; -------------------------------------------------------------- +[var_decl] + {inst} : "{fbtype}"; // {comment} +; -------------------------------------------------------------- +[call_1sep] + REGION {inst} ({shorttype}) — {comment} + #{inst}.stInSeparator1.Settings.nSeparatorNo := "cSep{tro_no}.1"; + #{inst}.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #{inst}.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #{inst}.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #{inst}.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #{inst}.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cIn{sen_in_sep}"]; + #{inst}.stInSenJam2 := "DB_Inputs".Sensors["cIn{sen_jam}"]; + + #{inst}.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #{inst}(nInMainTroNo := "cMainTro{tro_no}", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.stData, + arInOutJamExit2 := "DB_JamArea{tro_no}".stJam{tro_no}_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea{tro_no}".stJam{tro_no}_2.stData, + xOutStopper1 => "{stopper}", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro{tro_no}"], + stInOutHMI := "DB_Interface_HMI".stTRO.{inst}); + END_REGION + +; -------------------------------------------------------------- +[call_1sep1swi] + REGION {inst} ({shorttype}) — {comment} + #{inst}.stInSeparator1.Settings.nSeparatorNo := "cSep{tro_no}.1"; + #{inst}.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #{inst}.stInSeparator1.Settings.tTrailingTime := T#100ms; // TODO Timing + #{inst}.stInSeparator1.Settings.tHandlingTime := T#50ms; // TODO Timing + #{inst}.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #{inst}.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cIn{sen_in_sep}"]; + #{inst}.stInSenJam2 := "DB_Inputs".Sensors["cIn{sen_jam}"]; + #{inst}.stInSwitch1.Settings.nSwitchNo := "cSwi{tro_no}.1"; + + #{inst}(nInMainTroNo := "cMainTro{tro_no}", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun1 := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.stData, + arInOutJamExit2 := "DB_JamArea{tro_no}".stJam{tro_no}_2.arCarrier, // TODO Topologie (Dir1) + stInOutJamExit2 := "DB_JamArea{tro_no}".stJam{tro_no}_2.stData, + arInOutJamExit3 := "DB_JamArea{tro_no}".stJam{tro_no}_3.arCarrier, // TODO Topologie (Dir2) + stInOutJamExit3 := "DB_JamArea{tro_no}".stJam{tro_no}_3.stData, + xOutStopper1 => "{stopper}", + xOutSw1ExTo3 => "{switch_out}", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro{tro_no}"], + stInOutHMI := "DB_Interface_HMI".stTRO.{inst}); + END_REGION + +; -------------------------------------------------------------- +[call_vario] + REGION {inst} ({shorttype}) — {comment} + #{inst}.stInSeparator1.Settings.nSeparatorNo := "cSep{tro_no}.1"; + #{inst}.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #{inst}.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cIn{sen_in_sep}"]; + #{inst}.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cIn{sen_carr_in_pos}"]; + #{inst}.stInVario.stSenFinger := "DB_Inputs".Sensors["cIn{sen_finger}"]; + #{inst}.stInVario.stSenJam := "DB_Inputs".Sensors["cIn{sen_jam}"]; + + #{inst}(nInMainTroNo := "cMainTro{tro_no}", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.stData, + arInOutJamFinger := "DB_JamArea{tro_no}".stJam{tro_no}_2.arCarrier, // TODO Topologie + xOutStopper => "{stopper}", + xOutVarioMotor => "{motor}", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro{tro_no}"], + stInOutHMI := "DB_Interface_HMI".stTRO.{inst}); + END_REGION + +; -------------------------------------------------------------- +[call_conveyor] + REGION {inst} — {comment} + #{inst}.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #{inst}.Settings.xGridActive := FALSE; // TODO Grid + #{inst}.Settings.sMotorProtectName := '{motor_protection}'; + + #{inst}(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "{motor_protection}", + xInPowerContactor := "{motor}", + stInOutHMI := "DB_Interface_HMI".stConveyors.{inst}); + END_REGION + +; -------------------------------------------------------------- +[call_sensor] + // {comment} + #fbSensorInput(stInSensorHW := "{bmk}", + nInSensorNo := "cIn{bmk}", + stInOutSensor := "DB_Inputs".Sensors["cIn{bmk}"]); +; -------------------------------------------------------------- +[fb_main_frame] +FUNCTION_BLOCK "FB_Main_skel_{uh}" +{{ S7_Optimized_Access := 'TRUE' }} +VERSION : 0.1 +// ============================================================ +// AUTOMATISCH GENERIERTES GRUNDGERUEST — create_skel.py +// Quelle: E/A-Listen {uh} (data/) +// TODO-Marken kennzeichnen manuell zu ergaenzende Stellen +// (Timings, Topologie/JamAreas, Safety, Release, Priority). +// ============================================================ + VAR +{var_block} END_VAR + +BEGIN +{call_block}END_FUNCTION_BLOCK +; -------------------------------------------------------------- +[fb_sensors_frame] +FUNCTION_BLOCK "FB_CallSensors_skel_{uh}" +{{ S7_Optimized_Access := 'TRUE' }} +VERSION : 0.1 +// AUTOMATISCH GENERIERT — create_skel.py ({count} Sensoren) + VAR + fbSensorInput : "FB_SensorInput"; + END_VAR + +BEGIN +{call_block}END_FUNCTION_BLOCK diff --git a/data/ST500592_10_5-14_ILS-1_TIA.xlsx b/data/ST500592_10_5-14_ILS-1_TIA.xlsx new file mode 100644 index 0000000..70104af Binary files /dev/null and b/data/ST500592_10_5-14_ILS-1_TIA.xlsx differ diff --git a/data/ST500592_10_5-14_ILS-2_TIA.xlsx b/data/ST500592_10_5-14_ILS-2_TIA.xlsx new file mode 100644 index 0000000..5459529 Binary files /dev/null and b/data/ST500592_10_5-14_ILS-2_TIA.xlsx differ diff --git a/data/ST500592_10_5-14_ILS-3_TIA.xlsx b/data/ST500592_10_5-14_ILS-3_TIA.xlsx new file mode 100644 index 0000000..8a51aeb Binary files /dev/null and b/data/ST500592_10_5-14_ILS-3_TIA.xlsx differ diff --git a/data/ST500592_10_5-14_ILS-4_TIA.xlsx b/data/ST500592_10_5-14_ILS-4_TIA.xlsx new file mode 100644 index 0000000..49492cb Binary files /dev/null and b/data/ST500592_10_5-14_ILS-4_TIA.xlsx differ diff --git a/data/ST500592_10_5-14_ILS-5_TIA.xlsx b/data/ST500592_10_5-14_ILS-5_TIA.xlsx new file mode 100644 index 0000000..f3566fc Binary files /dev/null and b/data/ST500592_10_5-14_ILS-5_TIA.xlsx differ diff --git a/data/ST500592_10_5-9_ILS_positions.json b/data/ST500592_10_5-9_ILS_positions.json new file mode 100644 index 0000000..cc6e9e1 --- /dev/null +++ b/data/ST500592_10_5-9_ILS_positions.json @@ -0,0 +1,101329 @@ +{ + "sensors": { + "BG3260@4": { + "A": "0", + "B": "BG3260", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 363417.8, + 451848.4 + ], + "IO": "BG3260", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (ILS-CV M0401)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI2", + "TEXT-D": "", + "TEXT-E": "=A01+UC0401", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3260@5": { + "A": "0", + "B": "BG3260", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220148.3, + 151237.7 + ], + "IO": "BG3260", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "5" + }, + "BG3260@1": { + "A": "0", + "B": "BG3260", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 330751.2, + 164939.4 + ], + "IO": "BG3260", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.01 (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "1.1.01", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG4620@3": { + "A": "0", + "B": "BG4620", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 251883.0, + 449160.2 + ], + "IO": "BG4620", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M4102)", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0090@3": { + "A": "0", + "B": "MA0090", + "C": "20090710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 253506.8, + 449008.7 + ], + "IO": "MA0090", + "ID": "9999", + "VERW": "ILS-CV M4102", + "BEZEICHNUNG": "Motor MA0090 (CV-M4102)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ5", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4622@3": { + "A": "0", + "B": "BG4622", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252960.1, + 449283.1 + ], + "IO": "BG4622", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4102)", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4621@3": { + "A": "0", + "B": "BG4621", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252428.0, + 448890.2 + ], + "IO": "BG4621", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M4102)", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4624@3": { + "A": "0", + "B": "BG4624", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 283386.0, + 448905.9 + ], + "IO": "BG4624", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M4102)", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4623@3": { + "A": "0", + "B": "BG4623", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 282646.2, + 448909.4 + ], + "IO": "BG4623", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4102)", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4625@3": { + "A": "0", + "B": "BG4625", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 281901.0, + 448905.9 + ], + "IO": "BG4625", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4102) ", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4632@3": { + "A": "0", + "B": "BG4632", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 254569.6, + 448295.3 + ], + "IO": "BG4632", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4202)", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4630@3": { + "A": "0", + "B": "BG4630", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 254566.9, + 448831.8 + ], + "IO": "BG4630", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M4202)", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4631@3": { + "A": "0", + "B": "BG4631", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 254566.9, + 448561.8 + ], + "IO": "BG4631", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M4202)", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4633@3": { + "A": "0", + "B": "BG4633", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 283939.1, + 446445.0 + ], + "IO": "BG4633", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M4202)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0091@3": { + "A": "0", + "B": "MA0091", + "C": "20091710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 253157.5, + 447432.0 + ], + "IO": "MA0091", + "ID": "9999", + "VERW": "ILS-CV M4202", + "BEZEICHNUNG": "Motor MA0091 (CV-M4202)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ5", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4635@3": { + "A": "0", + "B": "BG4635", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 282381.6, + 446714.1 + ], + "IO": "BG4635", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4202)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4643@3": { + "A": "0", + "B": "BG4643", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 285422.4, + 448905.9 + ], + "IO": "BG4643", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M4301) ", + "KENNZEICHNUNG": "=A01+UC0312-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0093@3": { + "A": "0", + "B": "MA0093", + "C": "20093710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 285574.0, + 446713.9 + ], + "IO": "MA0093", + "ID": "9999", + "VERW": "ILS-CV M4401", + "BEZEICHNUNG": "Motor MA0093 (CV-M4401)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ5", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4654@3": { + "A": "0", + "B": "BG4654", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 284839.4, + 446718.1 + ], + "IO": "BG4654", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4401)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4653@3": { + "A": "0", + "B": "BG4653", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 286322.6, + 446987.0 + ], + "IO": "BG4653", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M4401)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4640@3": { + "A": "0", + "B": "BG4640", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 253789.4, + 445954.5 + ], + "IO": "BG4640", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M4301)", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0092@3": { + "A": "0", + "B": "MA0092", + "C": "20092710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 285986.7, + 448499.3 + ], + "IO": "MA0092", + "ID": "9999", + "VERW": "ILS-CV M4301", + "BEZEICHNUNG": "Motor MA0092 (CV-M4301)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ5", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4642@3": { + "A": "0", + "B": "BG4642", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 254539.8, + 446228.7 + ], + "IO": "BG4642", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4301)", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4641@3": { + "A": "0", + "B": "BG4641", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 255274.4, + 446224.5 + ], + "IO": "BG4641", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4301)", + "KENNZEICHNUNG": "=A01+U0312-KF1FDI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4652@3": { + "A": "0", + "B": "BG4652", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252321.6, + 446227.9 + ], + "IO": "BG4652", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4401)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4650@3": { + "A": "0", + "B": "BG4650", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 251887.7, + 445684.5 + ], + "IO": "BG4650", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M4401)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4651@3": { + "A": "0", + "B": "BG4651", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252998.3, + 445954.5 + ], + "IO": "BG4651", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4401)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4644@3": { + "A": "0", + "B": "BG4644", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 284687.9, + 448910.1 + ], + "IO": "BG4644", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor (ILS-CV M4301)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0146@1": { + "A": "0", + "B": "MA0146", + "C": "20146710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 317463.6, + 449302.2 + ], + "IO": "MA0146", + "ID": "9999", + "VERW": "ILS-CV M4103", + "BEZEICHNUNG": "Motor MA0146 (CV-M4103)", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ05", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0146@2": { + "A": "0", + "B": "MA0146", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214008.4, + 310807.6 + ], + "IO": "MA0146", + "ID": "9999", + "VERW": "ILS-CV M1109", + "BEZEICHNUNG": "Motor MA0146 (CV-M1109)", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ3", + "TEXT-D": "Motor MA0146", + "TEXT-E": "Motor MA0146", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3006@1": { + "A": "0", + "B": "BG3006", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 318214.0, + 449306.3 + ], + "IO": "BG3006", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4103)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3006@3": { + "A": "0", + "B": "BG3006", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187126.0, + 456370.0 + ], + "IO": "BG3006", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2105)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3006@2": { + "A": "0", + "B": "BG3006", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187126.0, + 306346.4 + ], + "IO": "BG3006", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1105)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3005@1": { + "A": "0", + "B": "BG3005", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 316721.1, + 449302.2 + ], + "IO": "BG3005", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M4103)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3005@3": { + "A": "0", + "B": "BG3005", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187126.0, + 456968.4 + ], + "IO": "BG3005", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K2105 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3005@2": { + "A": "0", + "B": "BG3005", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187126.0, + 306968.4 + ], + "IO": "BG3005", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (CV-M1105 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3124@1": { + "A": "0", + "B": "BG3124", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 317703.5, + 446786.6 + ], + "IO": "BG3124", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M4203)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3124@3": { + "A": "0", + "B": "BG3124", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206614.4, + 457439.4 + ], + "IO": "BG3124", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3124@2": { + "A": "0", + "B": "BG3124", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206614.4, + 307169.4 + ], + "IO": "BG3124", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3130@1": { + "A": "0", + "B": "BG3130", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 320086.4, + 449305.0 + ], + "IO": "BG3130", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M4302)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3130@3": { + "A": "0", + "B": "BG3130", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214297.6, + 459122.4 + ], + "IO": "BG3130", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2102 Einfahrt Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3130@2": { + "A": "0", + "B": "BG3130", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214297.6, + 309122.4 + ], + "IO": "BG3130", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1102 Einfahrt Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0150@1": { + "A": "0", + "B": "MA0150", + "C": "20150710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 321585.5, + 449302.4 + ], + "IO": "MA0150", + "ID": "9999", + "VERW": "ILS-CV M4302", + "BEZEICHNUNG": "Motor MA0150 (CV-M4302)", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ06", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3131@1": { + "A": "0", + "B": "BG3131", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 322328.0, + 449302.4 + ], + "IO": "BG3131", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4302)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3131@3": { + "A": "0", + "B": "BG3131", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218467.0, + 459122.4 + ], + "IO": "BG3131", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K2102 Einfahrt Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3131@2": { + "A": "0", + "B": "BG3131", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218467.0, + 309122.4 + ], + "IO": "BG3131", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1102 Einfahrt Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3137@1": { + "A": "0", + "B": "BG3137", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 321386.8, + 446793.0 + ], + "IO": "BG3137", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4402)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3137@3": { + "A": "0", + "B": "BG3137", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207625.0, + 459467.0 + ], + "IO": "BG3137", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3137@2": { + "A": "0", + "B": "BG3137", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207135.3, + 309810.7 + ], + "IO": "BG3137", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3135@1": { + "A": "0", + "B": "BG3135", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 320641.6, + 446789.7 + ], + "IO": "BG3135", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M4402)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3135@3": { + "A": "0", + "B": "BG3135", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223253.0, + 460126.4 + ], + "IO": "BG3135", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV 1 M1109)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3135@2": { + "A": "0", + "B": "BG3135", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213222.0, + 310541.6 + ], + "IO": "BG3135", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 1 (M1109)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3136@1": { + "A": "0", + "B": "BG3136", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 322126.6, + 446789.5 + ], + "IO": "BG3136", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4402)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3136@3": { + "A": "0", + "B": "BG3136", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222191.5, + 459489.6 + ], + "IO": "BG3136", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2102)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3136@2": { + "A": "0", + "B": "BG3136", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214754.0, + 310822.2 + ], + "IO": "BG3136", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1109)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3060@1": { + "A": "0", + "B": "BG3060", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 360615.0, + 453809.0 + ], + "IO": "BG3060", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M4503)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3060@3": { + "A": "0", + "B": "BG3060", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204368.7, + 457871.7 + ], + "IO": "BG3060", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3060@2": { + "A": "0", + "B": "BG3060", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204368.7, + 307871.7 + ], + "IO": "BG3060", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1106)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0141@1": { + "A": "0", + "B": "MA0141", + "C": "20141710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 363918.3, + 453815.0 + ], + "IO": "MA0141", + "ID": "9999", + "VERW": "ILS-CV M4503", + "BEZEICHNUNG": "Motor MA0141 (CV-M4503)", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ05", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0141@3": { + "A": "0", + "B": "MA0141", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205963.8, + 459541.5 + ], + "IO": "MA0141", + "ID": "9999", + "VERW": "KR M2102 0,55", + "BEZEICHNUNG": "Motor MA0141 (KR-M2102)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "Motor MA0141", + "TEXT-E": "Motor MA0141", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0141@2": { + "A": "0", + "B": "MA0141", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205878.2, + 310078.0 + ], + "IO": "MA0141", + "ID": "9999", + "VERW": "ILS-KR M1102", + "BEZEICHNUNG": "Motor MA0141 (KR-M1102)", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3062@1": { + "A": "0", + "B": "BG3062", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 365411.3, + 453819.1 + ], + "IO": "BG3062", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor (ILS-CV M4503)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3062@3": { + "A": "0", + "B": "BG3062", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203729.6, + 459134.2 + ], + "IO": "BG3062", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K2101 Einfahrt Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3062@2": { + "A": "0", + "B": "BG3062", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203729.6, + 309134.2 + ], + "IO": "BG3062", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1101 Einfahrt Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3061@1": { + "A": "0", + "B": "BG3061", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 364660.8, + 453815.0 + ], + "IO": "BG3061", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M4503)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3061@3": { + "A": "0", + "B": "BG3061", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204081.7, + 458835.0 + ], + "IO": "BG3061", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2101 ) Block 2.1.2", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3061@2": { + "A": "0", + "B": "BG3061", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204081.7, + 308835.0 + ], + "IO": "BG3061", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1101 ) Block 1.1.2", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3065@1": { + "A": "0", + "B": "BG3065", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358922.5, + 453812.5 + ], + "IO": "BG3065", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4502)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3065@3": { + "A": "0", + "B": "BG3065", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204362.7, + 456968.4 + ], + "IO": "BG3065", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K2101 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3065@2": { + "A": "0", + "B": "BG3065", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204362.7, + 306968.4 + ], + "IO": "BG3065", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K1101 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3063@1": { + "A": "0", + "B": "BG3063", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359662.3, + 453809.0 + ], + "IO": "BG3063", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M4502)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3063@3": { + "A": "0", + "B": "BG3063", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204280.3, + 459470.5 + ], + "IO": "BG3063", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor Str.2 (KR-M2101)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3063@2": { + "A": "0", + "B": "BG3063", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204281.0, + 309470.4 + ], + "IO": "BG3063", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor Str.2 (KR-M1101)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3064@1": { + "A": "0", + "B": "BG3064", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358178.1, + 453809.6 + ], + "IO": "BG3064", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4502))", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3064@3": { + "A": "0", + "B": "BG3064", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204364.4, + 457279.5 + ], + "IO": "BG3064", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3064@2": { + "A": "0", + "B": "BG3064", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204364.4, + 307279.5 + ], + "IO": "BG3064", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1106)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0144@1": { + "A": "0", + "B": "MA0144", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339956.2, + 457568.5 + ], + "IO": "MA0144", + "ID": "9999", + "VERW": "ILS-CV M4501", + "BEZEICHNUNG": "Motor MA0144 (CV-M4501)", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ05", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0144@3": { + "A": "0", + "B": "MA0144", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206612.7, + 456830.9 + ], + "IO": "MA0144", + "ID": "9999", + "VERW": "ICV M2107 0,75", + "BEZEICHNUNG": "Motor MA0144 (CV-M2107)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0144@2": { + "A": "0", + "B": "MA0144", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206609.5, + 306548.5 + ], + "IO": "MA0144", + "ID": "9999", + "VERW": "ILS-CV M1107", + "BEZEICHNUNG": "Motor MA0144 (CV-M1107)", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3022@1": { + "A": "0", + "B": "BG3022", + "C": "20073710081010151939", + "ARTINR": "829434306", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339962.8, + 457975.1 + ], + "IO": "BG3022", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 1 (ILS-CV M4501)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3023@1": { + "A": "0", + "B": "BG3023", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339956.2, + 457156.6 + ], + "IO": "BG3023", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor (ILS-CV M4501)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0145@1": { + "A": "0", + "B": "MA0145", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337719.9, + 463722.0 + ], + "IO": "MA0145", + "ID": "9999", + "VERW": "ILS-CV M4104", + "BEZEICHNUNG": "Motor MA0145 (CV-M4104)", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ05", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0145@3": { + "A": "0", + "B": "MA0145", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227612.4, + 456662.2 + ], + "IO": "MA0145", + "ID": "9999", + "VERW": "CV M2108 0,75", + "BEZEICHNUNG": "Motor MA0145 (CV-M2108)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0145@2": { + "A": "0", + "B": "MA0145", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227609.6, + 306631.5 + ], + "IO": "MA0145", + "ID": "9999", + "VERW": "ILS-CV M1108", + "BEZEICHNUNG": "Motor MA0145 (CV-M1108)", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3001@1": { + "A": "0", + "B": "BG3001", + "C": "20073710081010151939", + "ARTINR": "829434306", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337726.1, + 463263.8 + ], + "IO": "BG3001", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 1 (ILS-CV M4104)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3001@3": { + "A": "0", + "B": "BG3001", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187137.4, + 458835.0 + ], + "IO": "BG3001", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2101 ) Block 2.1.1", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3001@2": { + "A": "0", + "B": "BG3001", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187137.4, + 308835.0 + ], + "IO": "BG3001", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1101 ) Block 1.1.1", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3000@1": { + "A": "0", + "B": "BG3000", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337728.9, + 464143.0 + ], + "IO": "BG3000", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4104)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3000@3": { + "A": "0", + "B": "BG3000", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187132.0, + 457871.7 + ], + "IO": "BG3000", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3000@2": { + "A": "0", + "B": "BG3000", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187132.0, + 307871.7 + ], + "IO": "BG3000", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1105)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0140@1": { + "A": "0", + "B": "MA0140", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 336252.7, + 451772.7 + ], + "IO": "MA0140", + "ID": "9999", + "VERW": "ILS-KR-M4204", + "BEZEICHNUNG": "Motor MA0140 (KR-M4204)", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ05", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0140@3": { + "A": "0", + "B": "MA0140", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 169288.8, + 459558.0 + ], + "IO": "MA0140", + "ID": "9999", + "VERW": "KR M2101 0,75", + "BEZEICHNUNG": "Motor MA0140 (KR-M2101)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "Motor MA0140", + "TEXT-E": "Motor MA0140", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0140@2": { + "A": "0", + "B": "MA0140", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 169285.6, + 309555.3 + ], + "IO": "MA0140", + "ID": "9999", + "VERW": "ILS-KR M1101", + "BEZEICHNUNG": "Motor MA0140 (KR-M1101)", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ3", + "TEXT-D": "Motor MA0140", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3002@1": { + "A": "0", + "B": "BG3002", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337828.8, + 458991.6 + ], + "IO": "BG3002", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4103)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3002@3": { + "A": "0", + "B": "BG3002", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186658.6, + 459134.2 + ], + "IO": "BG3002", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K2101 Einfahrt Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3002@2": { + "A": "0", + "B": "BG3002", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186658.6, + 309134.2 + ], + "IO": "BG3002", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1101 Einfahrt Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3003@1": { + "A": "0", + "B": "BG3003", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337826.1, + 458045.6 + ], + "IO": "BG3003", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M4103)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3003@3": { + "A": "0", + "B": "BG3003", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187941.8, + 458835.0 + ], + "IO": "BG3003", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2101)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3003@2": { + "A": "0", + "B": "BG3003", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187941.8, + 308835.0 + ], + "IO": "BG3003", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M1101 Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3004@1": { + "A": "0", + "B": "BG3004", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337826.1, + 458652.7 + ], + "IO": "BG3004", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4103)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3004@3": { + "A": "0", + "B": "BG3004", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187127.8, + 457279.5 + ], + "IO": "BG3004", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3004@2": { + "A": "0", + "B": "BG3004", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187127.8, + 307279.5 + ], + "IO": "BG3004", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1105)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3021@1": { + "A": "0", + "B": "BG3021", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339852.7, + 452547.1 + ], + "IO": "BG3021", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4501)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3020@1": { + "A": "0", + "B": "BG3020", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339850.0, + 451981.6 + ], + "IO": "BG3020", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M4501)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3017@1": { + "A": "0", + "B": "BG3017", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339850.0, + 451672.1 + ], + "IO": "BG3017", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M4501)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3024@1": { + "A": "0", + "B": "BG3024", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340763.2, + 451843.0 + ], + "IO": "BG3024", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M4203)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3016@1": { + "A": "0", + "B": "BG3016", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339850.0, + 451372.0 + ], + "IO": "BG3016", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS-KR-M4204)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3013@1": { + "A": "0", + "B": "BG3013", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339798.4, + 449335.3 + ], + "IO": "BG3013", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-KR-M4204)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3125@1": { + "A": "0", + "B": "BG3125", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 338356.4, + 449090.6 + ], + "IO": "BG3125", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M4302)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3125@3": { + "A": "0", + "B": "BG3125", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206612.7, + 457128.2 + ], + "IO": "BG3125", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K2107 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3125@2": { + "A": "0", + "B": "BG3125", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206612.7, + 306858.2 + ], + "IO": "BG3125", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K1102 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3075@1": { + "A": "0", + "B": "BG3075", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 338213.4, + 446668.3 + ], + "IO": "BG3075", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4403)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3074@1": { + "A": "0", + "B": "BG3074", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 338953.2, + 446664.9 + ], + "IO": "BG3074", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4403)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0151@1": { + "A": "0", + "B": "MA0151", + "C": "20151710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 325573.6, + 446789.5 + ], + "IO": "MA0151", + "ID": "9999", + "VERW": "ILS-CV M4402", + "BEZEICHNUNG": "Motor MA0151 (CV-M4402)", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ06", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3133@1": { + "A": "0", + "B": "BG3133", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 324835.9, + 446793.7 + ], + "IO": "BG3133", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4402)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3133@3": { + "A": "0", + "B": "BG3133", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225265.9, + 459122.4 + ], + "IO": "BG3133", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.6 (KR-K2102 Einfahrt Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3133@2": { + "A": "0", + "B": "BG3133", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225265.9, + 309122.4 + ], + "IO": "BG3133", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.6 (KR-K1102 Einfahrt Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3134@1": { + "A": "0", + "B": "BG3134", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 327054.8, + 446789.5 + ], + "IO": "BG3134", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M4402)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3134@3": { + "A": "0", + "B": "BG3134", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224498.3, + 459859.1 + ], + "IO": "BG3134", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (KR-M2102 Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3134@2": { + "A": "0", + "B": "BG3134", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212479.5, + 310541.6 + ], + "IO": "BG3134", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3126@1": { + "A": "0", + "B": "BG3126", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 326272.8, + 448899.6 + ], + "IO": "BG3126", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M4302)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3126@3": { + "A": "0", + "B": "BG3126", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206612.7, + 456532.7 + ], + "IO": "BG3126", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2107)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3126@2": { + "A": "0", + "B": "BG3126", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206612.7, + 306253.0 + ], + "IO": "BG3126", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 1106)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0147@1": { + "A": "0", + "B": "MA0147", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 316837.8, + 446806.3 + ], + "IO": "MA0147", + "ID": "9999", + "VERW": "ILS-CV M4203", + "BEZEICHNUNG": "Motor MA0147 (CV-M4203)", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ05", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3121@1": { + "A": "0", + "B": "BG3121", + "C": "20073710081010151939", + "ARTINR": "829434306", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337068.7, + 448870.6 + ], + "IO": "BG3121", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4203)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3121@3": { + "A": "0", + "B": "BG3121", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207130.0, + 458839.1 + ], + "IO": "BG3121", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2102 ) Block 2.1.3", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3121@2": { + "A": "0", + "B": "BG3121", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207166.3, + 308839.1 + ], + "IO": "BG3121", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1102 ) Block 1.1.3", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3120@1": { + "A": "0", + "B": "BG3120", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337068.7, + 449398.6 + ], + "IO": "BG3120", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M4203)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3120@3": { + "A": "0", + "B": "BG3120", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207564.0, + 457473.8 + ], + "IO": "BG3120", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3120@2": { + "A": "0", + "B": "BG3120", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207427.8, + 307734.6 + ], + "IO": "BG3120", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3291@1": { + "A": "0", + "B": "BG3291", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340302.8, + 463010.4 + ], + "IO": "BG3291", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M0100)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "=A01+UC0101-KF1DI3", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3291@3": { + "A": "0", + "B": "BG3291", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 442667.5 + ], + "IO": "BG3291", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 18 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.18", + "SPS": "3" + }, + "BG3291@2": { + "A": "0", + "B": "BG3291", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 292667.5 + ], + "IO": "BG3291", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 18 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.18", + "SPS": "2" + }, + "BG3290@1": { + "A": "0", + "B": "BG3290", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340300.1, + 463582.9 + ], + "IO": "BG3290", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M0100)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "=A01+UC0101-KF1DI3", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3290@3": { + "A": "0", + "B": "BG3290", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 442667.5 + ], + "IO": "BG3290", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.17", + "SPS": "3" + }, + "BG3290@2": { + "A": "0", + "B": "BG3290", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 292667.5 + ], + "IO": "BG3290", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.17", + "SPS": "2" + }, + "BG3292@1": { + "A": "0", + "B": "BG3292", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340300.1, + 463293.9 + ], + "IO": "BG3292", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M0100)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "=A01+UC0101-KF1DI3", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3292@3": { + "A": "0", + "B": "BG3292", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 442667.5 + ], + "IO": "BG3292", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "In Separator 19 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.19", + "SPS": "3" + }, + "BG3292@2": { + "A": "0", + "B": "BG3292", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 292667.5 + ], + "IO": "BG3292", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "In Separator 19 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.19", + "SPS": "2" + }, + "MA0143@1": { + "A": "0", + "B": "MA0143", + "C": "20143710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 357639.7, + 451720.4 + ], + "IO": "MA0143", + "ID": "9999", + "VERW": "CV-M0143_0,55", + "BEZEICHNUNG": "Motor MA0143 (CV-M4403)", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ05", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0143@3": { + "A": "0", + "B": "MA0143", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204362.7, + 456671.8 + ], + "IO": "MA0143", + "ID": "9999", + "VERW": "CV M2106 0,75", + "BEZEICHNUNG": "Motor MA0143 (CV-M2106)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0143@2": { + "A": "0", + "B": "MA0143", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204359.6, + 306631.2 + ], + "IO": "MA0143", + "ID": "9999", + "VERW": "ILS-CV M1106", + "BEZEICHNUNG": "Motor MA0143 (CV-M1106)", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3071@1": { + "A": "0", + "B": "BG3071", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356897.2, + 451720.4 + ], + "IO": "BG3071", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 1 (ILS-CV M4403)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3071@3": { + "A": "0", + "B": "BG3071", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193555.9, + 459122.4 + ], + "IO": "BG3071", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K2101 Einfahrt Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3071@2": { + "A": "0", + "B": "BG3071", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193555.9, + 309122.4 + ], + "IO": "BG3071", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1101 Einfahrt Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3070@1": { + "A": "0", + "B": "BG3070", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356383.1, + 451994.6 + ], + "IO": "BG3070", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor (ILS-CV M4403)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3070@3": { + "A": "0", + "B": "BG3070", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196641.7, + 459124.6 + ], + "IO": "BG3070", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2101 Einfahrt Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3070@2": { + "A": "0", + "B": "BG3070", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196641.7, + 309124.6 + ], + "IO": "BG3070", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1101 Einfahrt Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3072@1": { + "A": "0", + "B": "BG3072", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358560.7, + 452260.4 + ], + "IO": "BG3072", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 2 (ILS-CV M4403)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3072@3": { + "A": "0", + "B": "BG3072", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189533.1, + 459122.4 + ], + "IO": "BG3072", + "ID": "", + "VERW": "Sync P5", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K2101 Einfahrt Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3072@2": { + "A": "0", + "B": "BG3072", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189533.1, + 309122.4 + ], + "IO": "BG3072", + "ID": "", + "VERW": "Sync P5", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K1101 Einfahrt Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3014@1": { + "A": "0", + "B": "BG3014", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340480.9, + 449875.3 + ], + "IO": "BG3014", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS-KR-M4204)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3012@1": { + "A": "0", + "B": "BG3012", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339281.0, + 449880.4 + ], + "IO": "BG3012", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (ILS-KR-M4204)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3012@3": { + "A": "0", + "B": "BG3012", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172113.1, + 459122.4 + ], + "IO": "BG3012", + "ID": "", + "VERW": "Sync P5", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K2101 Einfahrt Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3012@2": { + "A": "0", + "B": "BG3012", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172113.1, + 309122.4 + ], + "IO": "BG3012", + "ID": "", + "VERW": "Sync P5", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K1101 Einfahrt Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3073@1": { + "A": "0", + "B": "BG3073", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337468.2, + 446394.9 + ], + "IO": "BG3073", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M4403)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3073@3": { + "A": "0", + "B": "BG3073", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188790.6, + 459122.4 + ], + "IO": "BG3073", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor MT vor Pinband (KR-M2101 Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3073@2": { + "A": "0", + "B": "BG3073", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188790.6, + 309122.4 + ], + "IO": "BG3073", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor MT vor Pinband (KR-M1101 Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0142@1": { + "A": "0", + "B": "MA0142", + "C": "20142710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355696.0, + 453607.5 + ], + "IO": "MA0142", + "ID": "9999", + "VERW": "CV-M0142_0,55", + "BEZEICHNUNG": "Motor MA0142 (CV-M4502)", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ05", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0142@3": { + "A": "0", + "B": "MA0142", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187126.0, + 456662.9 + ], + "IO": "MA0142", + "ID": "9999", + "VERW": "CV M2105 0,75", + "BEZEICHNUNG": "Motor MA0142 (ILS-CV M2105)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0142@2": { + "A": "0", + "B": "MA0142", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187122.9, + 306636.6 + ], + "IO": "MA0142", + "ID": "9999", + "VERW": "ILS-CV M1105", + "BEZEICHNUNG": "Motor MA0142 (CV-M1105)", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ3", + "TEXT-D": "Motor MA0142", + "TEXT-E": "Motor MA0142", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3066@1": { + "A": "0", + "B": "BG3066", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 357181.0, + 453611.9 + ], + "IO": "BG3066", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4502)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3066@3": { + "A": "0", + "B": "BG3066", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204356.5, + 456371.0 + ], + "IO": "BG3066", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2106)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": " ", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3066@2": { + "A": "0", + "B": "BG3066", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204356.5, + 306333.1 + ], + "IO": "BG3066", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1106)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3067@1": { + "A": "0", + "B": "BG3067", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356438.5, + 453607.5 + ], + "IO": "BG3067", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 1 (ILS-CV M4502)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3067@3": { + "A": "0", + "B": "BG3067", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200294.7, + 459122.4 + ], + "IO": "BG3067", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K2101 Einfahrt Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3067@2": { + "A": "0", + "B": "BG3067", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200294.7, + 309122.4 + ], + "IO": "BG3067", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1101 Einfahrt Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3015@1": { + "A": "0", + "B": "BG3015", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 338892.5, + 450624.7 + ], + "IO": "BG3015", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (ILS-KR-M4204)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3260@4": { + "A": "0", + "B": "MB3260", + "C": "20073710081010151939", + "ARTINR": "722001311", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 40m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 363417.8, + 452117.1 + ], + "IO": "MB3260", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (ILS-CV M0401)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3260@1": { + "A": "0", + "B": "MB3260", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331465.9, + 166214.3 + ], + "IO": "MB3260", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB4620@3": { + "A": "0", + "B": "MB4620", + "C": "20073710081010151939", + "ARTINR": "722001306", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 20m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 251883.0, + 449435.4 + ], + "IO": "MB4620", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M4102)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4624@3": { + "A": "0", + "B": "MB4624", + "C": "20073710081010151939", + "ARTINR": "722001307", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 25m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 283386.0, + 449181.1 + ], + "IO": "MB4624", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M4102)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4630@3": { + "A": "0", + "B": "MB4630", + "C": "20073710081010151939", + "ARTINR": "722001306", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 20m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 254566.9, + 449101.8 + ], + "IO": "MB4630", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M2308 Block 2.3.4) ", + "KENNZEICHNUNG": "=A01+UC0312-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4633@3": { + "A": "0", + "B": "MB4633", + "C": "20073710081010151939", + "ARTINR": "722001307", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 25m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 283939.1, + 446720.2 + ], + "IO": "MB4633", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M4202)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4640@3": { + "A": "0", + "B": "MB4640", + "C": "20073710081010151939", + "ARTINR": "722001306", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 20m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 253789.4, + 446229.7 + ], + "IO": "MB4640", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M4301)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4650@3": { + "A": "0", + "B": "MB4650", + "C": "20073710081010151939", + "ARTINR": "722001306", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 20m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 251887.7, + 445954.5 + ], + "IO": "MB4650", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M4401)", + "KENNZEICHNUNG": "=A01+U0312-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3135@1": { + "A": "0", + "B": "MB3135", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 320641.6, + 446519.7 + ], + "IO": "MB3135", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M4402)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3135@3": { + "A": "0", + "B": "MB3135", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223650.2, + 459856.4 + ], + "IO": "MB3135", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1109)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3060@1": { + "A": "0", + "B": "MB3060", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 360615.0, + 454084.2 + ], + "IO": "MB3060", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M4503)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3060@3": { + "A": "0", + "B": "MB3060", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204368.7, + 458141.7 + ], + "IO": "MB3060", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3060@2": { + "A": "0", + "B": "MB3060", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204368.7, + 308141.7 + ], + "IO": "MB3060", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1106)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3063@1": { + "A": "0", + "B": "MB3063", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359662.3, + 454079.0 + ], + "IO": "MB3063", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M4502)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3003@1": { + "A": "0", + "B": "MB3003", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337826.1, + 458315.6 + ], + "IO": "MB3003", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M4103)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3020@1": { + "A": "0", + "B": "MB3020", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339850.0, + 452251.6 + ], + "IO": "MB3020", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M4501)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3024@1": { + "A": "0", + "B": "MB3024", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340763.2, + 452113.0 + ], + "IO": "MB3024", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M4203)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3013@1": { + "A": "0", + "B": "MB3013", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339798.4, + 449605.3 + ], + "IO": "MB3013", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-KR-M4204)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3125@1": { + "A": "0", + "B": "MB3125", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 338356.4, + 449360.6 + ], + "IO": "MB3125", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M4302)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3073@1": { + "A": "0", + "B": "MB3073", + "C": "20073710081010151939", + "ARTINR": "722001307", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 25m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337468.2, + 446664.9 + ], + "IO": "MB3073", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M4403) ", + "KENNZEICHNUNG": "=A01+UC1102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3120@1": { + "A": "0", + "B": "MB3120", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337068.7, + 449673.9 + ], + "IO": "MB3120", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M4203)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3120@3": { + "A": "0", + "B": "MB3120", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207564.0, + 457743.8 + ], + "IO": "MB3120", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3120@2": { + "A": "0", + "B": "MB3120", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207427.8, + 308004.6 + ], + "IO": "MB3120", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3130@1": { + "A": "0", + "B": "MB3130", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 320086.4, + 449580.2 + ], + "IO": "MB3130", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M4302)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3290@1": { + "A": "0", + "B": "MB3290", + "C": "20073710081010151939", + "ARTINR": "722001312", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 50m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340300.1, + 463852.9 + ], + "IO": "MB3290", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M0100)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "=A01+UC0101-KF1DQ3", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3290@3": { + "A": "0", + "B": "MB3290", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 442937.5 + ], + "IO": "MB3290", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3290@2": { + "A": "0", + "B": "MB3290", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 292937.5 + ], + "IO": "MB3290", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3015@1": { + "A": "0", + "B": "MB3015", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339635.0, + 450624.7 + ], + "IO": "MB3015", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-KR-M4204)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3010@1": { + "A": "0", + "B": "BG3010", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337168.3, + 451775.4 + ], + "IO": "BG3010", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-KR-M4204)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3010@3": { + "A": "0", + "B": "BG3010", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178799.9, + 459122.4 + ], + "IO": "BG3010", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2101 Einfahrt Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3010@2": { + "A": "0", + "B": "BG3010", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178799.9, + 309122.4 + ], + "IO": "BG3010", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1101 Einfahrt Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3010@1": { + "A": "0", + "B": "MB3010", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337168.3, + 452045.4 + ], + "IO": "MB3010", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-KR-M4204)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3076@1": { + "A": "0", + "B": "BG3076", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359303.2, + 451990.4 + ], + "IO": "BG3076", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M4502)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3076@1": { + "A": "0", + "B": "MB3076", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359303.2, + 452260.4 + ], + "IO": "MB3076", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M4502)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG4634@3": { + "A": "0", + "B": "BG4634", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 283199.3, + 446718.4 + ], + "IO": "BG4634", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4202)", + "KENNZEICHNUNG": "=A01+UC0312-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3123@1": { + "A": "0", + "B": "BG3123", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 318453.9, + 446790.8 + ], + "IO": "BG3123", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor (ILS-CV M4203)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3123@3": { + "A": "0", + "B": "BG3123", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206622.0, + 458127.3 + ], + "IO": "BG3123", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (KR-M2102)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3123@2": { + "A": "0", + "B": "BG3123", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206622.0, + 308127.3 + ], + "IO": "BG3123", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor Str.2 (KR-M1102)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3132@1": { + "A": "0", + "B": "BG3132", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 320845.7, + 449305.9 + ], + "IO": "BG3132", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4302)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3132@3": { + "A": "0", + "B": "BG3132", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221678.7, + 459122.4 + ], + "IO": "BG3132", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K2102 Einfahrt Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3132@2": { + "A": "0", + "B": "BG3132", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221678.7, + 309122.4 + ], + "IO": "BG3132", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K1102 Einfahrt Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3127@1": { + "A": "0", + "B": "BG3127", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 325538.3, + 448903.7 + ], + "IO": "BG3127", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4302)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3127@3": { + "A": "0", + "B": "BG3127", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211110.0, + 459122.4 + ], + "IO": "BG3127", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K2102 Einfahrt Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3127@2": { + "A": "0", + "B": "BG3127", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211110.0, + 309122.4 + ], + "IO": "BG3127", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1102 Einfahrt Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3122@1": { + "A": "0", + "B": "BG3122", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337071.4, + 449132.1 + ], + "IO": "BG3122", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4302)", + "KENNZEICHNUNG": "=A01+UC1103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3122@3": { + "A": "0", + "B": "BG3122", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207628.8, + 459134.2 + ], + "IO": "BG3122", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K2102 Einfahrt Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3122@2": { + "A": "0", + "B": "BG3122", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207628.8, + 309134.2 + ], + "IO": "BG3122", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1102 Einfahrt Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4462@2": { + "A": "0", + "B": "BG4462", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241060.5, + 443305.7 + ], + "IO": "BG4462", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1401)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4461@2": { + "A": "0", + "B": "BG4461", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241057.8, + 443572.3 + ], + "IO": "BG4461", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1401) ", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4575@3": { + "A": "0", + "B": "BG4575", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 245419.1, + 446942.4 + ], + "IO": "BG4575", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M4201)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4562@3": { + "A": "0", + "B": "BG4562", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 245255.0, + 448215.6 + ], + "IO": "BG4562", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M4101)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4562@2": { + "A": "0", + "B": "BG4562", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250977.2, + 294983.2 + ], + "IO": "BG4562", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV 1801)", + "KENNZEICHNUNG": "=A01+UC0211-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4560@3": { + "A": "0", + "B": "BG4560", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243083.2, + 448714.8 + ], + "IO": "BG4560", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (KR-M2110)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4560@2": { + "A": "0", + "B": "BG4560", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 249222.5, + 295258.3 + ], + "IO": "BG4560", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 1801)", + "KENNZEICHNUNG": "=A01+UC0211-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4577@3": { + "A": "0", + "B": "BG4577", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243083.2, + 446432.8 + ], + "IO": "BG4577", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 3 (KR-M2110)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0074@3": { + "A": "0", + "B": "MA0074", + "C": "20074710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 247292.3, + 448417.5 + ], + "IO": "MA0074", + "ID": "9999", + "VERW": "ILS-CV M4101", + "BEZEICHNUNG": "Motor MA0074 (CV-M4101)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ9", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0074@2": { + "A": "0", + "B": "MA0074", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 245363.1, + 287811.9 + ], + "IO": "MA0074", + "ID": "9999", + "VERW": "ILS-CV M4701", + "BEZEICHNUNG": "Motor MA0074 (CV-M4701)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ8", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0074@1": { + "A": "0", + "B": "MA0074", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376718.9, + 181184.1 + ], + "IO": "MA0074", + "ID": "9999", + "VERW": "M0074 0,12", + "BEZEICHNUNG": "Motor 1 MA0074 Einfahren LS 2", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor 1 MA0074 Einfahren LS 2", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0074@4": { + "A": "0", + "B": "MA0074", + "C": "10074710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358837.6, + 750556.2 + ], + "IO": "MA0074", + "ID": "9999", + "VERW": "ILS-CV-M4010", + "BEZEICHNUNG": "Motor MA0074 (ILS-CV-M4010)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG4565@3": { + "A": "0", + "B": "BG4565", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 248034.8, + 448429.4 + ], + "IO": "BG4565", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4101)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4565@2": { + "A": "0", + "B": "BG4565", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 245368.9, + 286565.2 + ], + "IO": "BG4565", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1801) ", + "KENNZEICHNUNG": "=A01+UC0211-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4574@3": { + "A": "0", + "B": "BG4574", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 247197.7, + 447228.9 + ], + "IO": "BG4574", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4201)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0075@3": { + "A": "0", + "B": "MA0075", + "C": "20075710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 246339.0, + 448097.4 + ], + "IO": "MA0075", + "ID": "9999", + "VERW": "ILS-CV M7000", + "BEZEICHNUNG": "Motor MA0075 (CV-M4201)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ9", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0075@2": { + "A": "0", + "B": "MA0075", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243237.7, + 307724.8 + ], + "IO": "MA0075", + "ID": "9999", + "VERW": "ILS-KR M1110", + "BEZEICHNUNG": "Motor MA0075 (KR-M1110)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ8", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4566@3": { + "A": "0", + "B": "BG4566", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250493.0, + 448413.4 + ], + "IO": "BG4566", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M4101)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4567@3": { + "A": "0", + "B": "BG4567", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 249730.2, + 448419.5 + ], + "IO": "BG4567", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4101)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4567@2": { + "A": "0", + "B": "BG4567", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 246108.7, + 286561.8 + ], + "IO": "BG4567", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4701)", + "KENNZEICHNUNG": "=A01+UC0211-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4570@3": { + "A": "0", + "B": "BG4570", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 248985.0, + 448416.1 + ], + "IO": "BG4570", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4101) ", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4573@3": { + "A": "0", + "B": "BG4573", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 249758.2, + 446151.7 + ], + "IO": "BG4573", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4201)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4572@3": { + "A": "0", + "B": "BG4572", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250526.1, + 446139.7 + ], + "IO": "BG4572", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M4201)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4571@3": { + "A": "0", + "B": "BG4571", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 248615.9, + 446409.7 + ], + "IO": "BG4571", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4201)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4564@3": { + "A": "0", + "B": "BG4564", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 246548.2, + 448416.1 + ], + "IO": "BG4564", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 1 (ILS-CV M4101)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4564@2": { + "A": "0", + "B": "BG4564", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244623.7, + 287342.0 + ], + "IO": "BG4564", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M1801)", + "KENNZEICHNUNG": "=A01+UC0211-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3243@3": { + "A": "0", + "B": "BG3243", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187191.9, + 443224.4 + ], + "IO": "BG3243", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2105) ", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3243@2": { + "A": "0", + "B": "BG3243", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187302.9, + 293168.9 + ], + "IO": "BG3243", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1105)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3243@5": { + "A": "0", + "B": "BG3243", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218683.8, + 152003.3 + ], + "IO": "BG3243", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV-M5003) ", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 5m", + "SPS": "5" + }, + "BG3243@1": { + "A": "0", + "B": "BG3243", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340392.2, + 165626.1 + ], + "IO": "BG3243", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-K0111)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3243@4": { + "A": "0", + "B": "BG3243", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 378153.2, + 751438.6 + ], + "IO": "BG3243", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (AMR ILS-CV M4000) ", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3187@3": { + "A": "0", + "B": "BG3187", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231576.6, + 459136.8 + ], + "IO": "BG3187", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K2102 Einfahrt Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3187@2": { + "A": "0", + "B": "BG3187", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231576.6, + 309136.8 + ], + "IO": "BG3187", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1102 Einfahrt Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0062@3": { + "A": "0", + "B": "MA0062", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174435.6, + 438825.4 + ], + "IO": "MA0062", + "ID": "9999", + "VERW": "KR-M0062 0,55", + "BEZEICHNUNG": "Motor MA0062 (KR-M2201)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ4", + "TEXT-D": "Motor MA0062", + "TEXT-E": "Motor MA0062", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0062@2": { + "A": "0", + "B": "MA0062", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 169285.6, + 288555.3 + ], + "IO": "MA0062", + "ID": "9999", + "VERW": "ILS-KR M1201", + "BEZEICHNUNG": "Motor MA0062 (KR-M1201)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ7", + "TEXT-D": "Motor MA0062", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0062@5": { + "A": "0", + "B": "MA0062", + "C": "10063710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1 - HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215006.2, + 150922.0 + ], + "IO": "MA0062", + "ID": "9999", + "VERW": "ILS-KR M5002", + "BEZEICHNUNG": "Motor MA0062 (ILS-KR M5002)", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "Motor MA0062", + "TEXT-E": "Motor MA0062", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MA0062@4": { + "A": "0", + "B": "MA0062", + "C": "10091710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355567.2, + 729300.5 + ], + "IO": "MA0062", + "ID": "9999", + "VERW": "ILS-CV-M4005", + "BEZEICHNUNG": "Motor MA0062 (ILS-CV-M4005)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MA0062@1": { + "A": "0", + "B": "MA0062", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331179.0, + 165151.7 + ], + "IO": "MA0062", + "ID": "9999", + "VERW": "CV-M0103 0,55", + "BEZEICHNUNG": "Motor MA0062 (ILS-CV-PM0103)", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor MA0062", + "TEXT-E": "Motor MA0062", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0061@3": { + "A": "0", + "B": "MA0061", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206657.9, + 440585.1 + ], + "IO": "MA0061", + "ID": "9999", + "VERW": "ILS-KR M2104", + "BEZEICHNUNG": "Motor MA0061 (KR-M2104)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ4", + "TEXT-D": "Motor MA0061", + "TEXT-E": "Motor MA0061", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0061@2": { + "A": "0", + "B": "MA0061", + "C": "20063710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206045.4, + 290577.9 + ], + "IO": "MA0061", + "ID": "9999", + "VERW": "KR-M0061_0,55", + "BEZEICHNUNG": "Motor MA0061 (KR-M1104)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ7", + "TEXT-D": "Motor MA0061", + "TEXT-E": "Motor MA0061", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0061@5": { + "A": "0", + "B": "MA0061", + "C": "10063710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1 - HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224137.3, + 148284.3 + ], + "IO": "MA0061", + "ID": "9999", + "VERW": "ILS-CV M5001", + "BEZEICHNUNG": "Motor MA0061 (ILS-CV M5001)", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "Motor MA0061", + "TEXT-E": "Motor MA0061", + "TEXT-ES": "", + "TEXT-F": "4G1,5mm² 20m", + "SPS": "5" + }, + "MA0061@4": { + "A": "0", + "B": "MA0061", + "C": "10063710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1 - HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 352028.0, + 728890.6 + ], + "IO": "MA0061", + "ID": "9999", + "VERW": "ILS-CV-M4004", + "BEZEICHNUNG": "Motor MA0061 (ILS-CV-M4004)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MA0061@1": { + "A": "0", + "B": "MA0061", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 328202.2, + 152496.1 + ], + "IO": "MA0061", + "ID": "9999", + "VERW": "KR-M0102 0,55", + "BEZEICHNUNG": "Motor MA0061 (ILS-KR-M0102) Auslagerkreisel", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor MA0061", + "TEXT-E": "Motor MA0061", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3244@3": { + "A": "0", + "B": "BG3244", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187189.2, + 442645.6 + ], + "IO": "BG3244", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2105) ", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3244@2": { + "A": "0", + "B": "BG3244", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187300.2, + 292602.5 + ], + "IO": "BG3244", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1105)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3244@5": { + "A": "0", + "B": "BG3244", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218690.3, + 154332.0 + ], + "IO": "BG3244", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M5003)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "5" + }, + "BG3244@4": { + "A": "0", + "B": "BG3244", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 378163.4, + 750557.6 + ], + "IO": "BG3244", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4001)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3240@3": { + "A": "0", + "B": "BG3240", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186664.6, + 441059.5 + ], + "IO": "BG3240", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3240@2": { + "A": "0", + "B": "BG3240", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186664.6, + 291059.5 + ], + "IO": "BG3240", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3240@5": { + "A": "0", + "B": "BG3240", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216938.3, + 150042.3 + ], + "IO": "BG3240", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "5" + }, + "BG3240@4": { + "A": "0", + "B": "BG3240", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 378165.9, + 752021.3 + ], + "IO": "BG3240", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4000)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3240@1": { + "A": "0", + "B": "BG3240", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 341970.0, + 163236.5 + ], + "IO": "BG3240", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M0100)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3191@3": { + "A": "0", + "B": "BG3191", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238060.0, + 459126.0 + ], + "IO": "BG3191", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K2102 Einfahrt Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3191@2": { + "A": "0", + "B": "BG3191", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238060.0, + 309126.0 + ], + "IO": "BG3191", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1102 Einfahrt Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3190@3": { + "A": "0", + "B": "BG3190", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234839.3, + 459122.4 + ], + "IO": "BG3190", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2102 Einfahrt Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3190@2": { + "A": "0", + "B": "BG3190", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234839.3, + 309122.4 + ], + "IO": "BG3190", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1102 Einfahrt Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3007@3": { + "A": "0", + "B": "BG3007", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 341225.8, + 451084.9 + ], + "IO": "BG3007", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (ILS-KR-M4204)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3007@2": { + "A": "0", + "B": "BG3007", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183191.4, + 309127.8 + ], + "IO": "BG3007", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1101 Einfahrt Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3011@3": { + "A": "0", + "B": "BG3011", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175587.3, + 459122.4 + ], + "IO": "BG3011", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K2101 Einfahrt Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3011@2": { + "A": "0", + "B": "BG3011", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175587.3, + 309122.4 + ], + "IO": "BG3011", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1101 Einfahrt Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3011@1": { + "A": "0", + "B": "BG3011", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339850.9, + 452836.9 + ], + "IO": "BG3011", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4501))", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3283@3": { + "A": "0", + "B": "BG3283", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 442667.6 + ], + "IO": "BG3283", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.12", + "SPS": "3" + }, + "BG3283@2": { + "A": "0", + "B": "BG3283", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 292667.6 + ], + "IO": "BG3283", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.12", + "SPS": "2" + }, + "BG3283@1": { + "A": "0", + "B": "BG3283", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337121.7, + 163008.9 + ], + "IO": "BG3283", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M0107)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 15m", + "SPS": "1" + }, + "BG3282@3": { + "A": "0", + "B": "BG3282", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 442667.6 + ], + "IO": "BG3282", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.11", + "SPS": "3" + }, + "BG3282@2": { + "A": "0", + "B": "BG3282", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 292667.6 + ], + "IO": "BG3282", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.11", + "SPS": "2" + }, + "BG3282@1": { + "A": "0", + "B": "BG3282", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337121.9, + 164267.5 + ], + "IO": "BG3282", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M0107)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "1" + }, + "BG3281@3": { + "A": "0", + "B": "BG3281", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 442667.6 + ], + "IO": "BG3281", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.10", + "SPS": "3" + }, + "BG3281@2": { + "A": "0", + "B": "BG3281", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 292667.6 + ], + "IO": "BG3281", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.10", + "SPS": "2" + }, + "BG3281@1": { + "A": "0", + "B": "BG3281", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334141.4, + 159713.2 + ], + "IO": "BG3281", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor(ILS-BX1104)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 20m", + "SPS": "1" + }, + "BG3280@3": { + "A": "0", + "B": "BG3280", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 442667.6 + ], + "IO": "BG3280", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.09", + "SPS": "3" + }, + "BG3280@2": { + "A": "0", + "B": "BG3280", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 292667.6 + ], + "IO": "BG3280", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.09", + "SPS": "2" + }, + "BG3280@1": { + "A": "0", + "B": "BG3280", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334141.1, + 159162.0 + ], + "IO": "BG3280", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-BX1104)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 20m", + "SPS": "1" + }, + "BG3277@3": { + "A": "0", + "B": "BG3277", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 442667.6 + ], + "IO": "BG3277", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.08", + "SPS": "3" + }, + "BG3277@2": { + "A": "0", + "B": "BG3277", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 292667.6 + ], + "IO": "BG3277", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.08", + "SPS": "2" + }, + "BG3286@3": { + "A": "0", + "B": "BG3286", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 442667.5 + ], + "IO": "BG3286", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.15", + "SPS": "3" + }, + "BG3286@2": { + "A": "0", + "B": "BG3286", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 292667.5 + ], + "IO": "BG3286", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.15", + "SPS": "2" + }, + "BG3286@1": { + "A": "0", + "B": "BG3286", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340238.5, + 164101.6 + ], + "IO": "BG3286", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M0110)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "1" + }, + "BG3285@3": { + "A": "0", + "B": "BG3285", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 442667.5 + ], + "IO": "BG3285", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.14", + "SPS": "3" + }, + "BG3285@2": { + "A": "0", + "B": "BG3285", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 292667.5 + ], + "IO": "BG3285", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.14", + "SPS": "2" + }, + "BG3285@1": { + "A": "0", + "B": "BG3285", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340241.2, + 164375.0 + ], + "IO": "BG3285", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M0110)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "1" + }, + "BG3284@3": { + "A": "0", + "B": "BG3284", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 442667.6 + ], + "IO": "BG3284", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.13", + "SPS": "3" + }, + "BG3284@2": { + "A": "0", + "B": "BG3284", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 292667.6 + ], + "IO": "BG3284", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.13", + "SPS": "2" + }, + "BG3284@1": { + "A": "0", + "B": "BG3284", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337124.4, + 163578.9 + ], + "IO": "BG3284", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M0107)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "1" + }, + "BG3287@3": { + "A": "0", + "B": "BG3287", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 442667.5 + ], + "IO": "BG3287", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.16", + "SPS": "3" + }, + "BG3287@2": { + "A": "0", + "B": "BG3287", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 292667.5 + ], + "IO": "BG3287", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.16", + "SPS": "2" + }, + "BG3276@3": { + "A": "0", + "B": "BG3276", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 442667.6 + ], + "IO": "BG3276", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.07", + "SPS": "3" + }, + "BG3276@2": { + "A": "0", + "B": "BG3276", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 292667.6 + ], + "IO": "BG3276", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.07", + "SPS": "2" + }, + "BG3276@1": { + "A": "0", + "B": "BG3276", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334141.4, + 161135.0 + ], + "IO": "BG3276", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M0106)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3275@3": { + "A": "0", + "B": "BG3275", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 442667.6 + ], + "IO": "BG3275", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.06", + "SPS": "3" + }, + "BG3275@2": { + "A": "0", + "B": "BG3275", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 292667.6 + ], + "IO": "BG3275", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.06", + "SPS": "2" + }, + "BG3275@1": { + "A": "0", + "B": "BG3275", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334141.4, + 161687.4 + ], + "IO": "BG3275", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M0106)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "Förderer voll", + "TEXT-E": "conveyor full", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3274@3": { + "A": "0", + "B": "BG3274", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 442667.6 + ], + "IO": "BG3274", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.05", + "SPS": "3" + }, + "BG3274@2": { + "A": "0", + "B": "BG3274", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 292667.6 + ], + "IO": "BG3274", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.05", + "SPS": "2" + }, + "BG3274@1": { + "A": "0", + "B": "BG3274", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334108.6, + 163726.8 + ], + "IO": "BG3274", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M0106)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "1" + }, + "BG3273@3": { + "A": "0", + "B": "BG3273", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 442667.6 + ], + "IO": "BG3273", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.04", + "SPS": "3" + }, + "BG3273@2": { + "A": "0", + "B": "BG3273", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 292667.6 + ], + "IO": "BG3273", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.04", + "SPS": "2" + }, + "BG3273@1": { + "A": "0", + "B": "BG3273", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334111.3, + 164000.2 + ], + "IO": "BG3273", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M0106)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "1" + }, + "BG3272@3": { + "A": "0", + "B": "BG3272", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 442667.6 + ], + "IO": "BG3272", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.03", + "SPS": "3" + }, + "BG3272@2": { + "A": "0", + "B": "BG3272", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 292667.6 + ], + "IO": "BG3272", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.03", + "SPS": "2" + }, + "BG3272@1": { + "A": "0", + "B": "BG3272", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331115.4, + 164260.6 + ], + "IO": "BG3272", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M0103)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "1" + }, + "BG3271@3": { + "A": "0", + "B": "BG3271", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 442667.6 + ], + "IO": "BG3271", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.02", + "SPS": "3" + }, + "BG3271@2": { + "A": "0", + "B": "BG3271", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 292667.6 + ], + "IO": "BG3271", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.02", + "SPS": "2" + }, + "BG3271@1": { + "A": "0", + "B": "BG3271", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331115.1, + 163051.1 + ], + "IO": "BG3271", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M0103)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 15m", + "SPS": "1" + }, + "BG3270@3": { + "A": "0", + "B": "BG3270", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 442667.6 + ], + "IO": "BG3270", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.01", + "SPS": "3" + }, + "BG3270@2": { + "A": "0", + "B": "BG3270", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 292667.6 + ], + "IO": "BG3270", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.01", + "SPS": "2" + }, + "BG3270@1": { + "A": "0", + "B": "BG3270", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331107.8, + 163621.6 + ], + "IO": "BG3270", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV-M0103)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "1" + }, + "MA0064@3": { + "A": "0", + "B": "MA0064", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187126.0, + 435656.4 + ], + "IO": "MA0064", + "ID": "9999", + "VERW": "CV M2205 0,75", + "BEZEICHNUNG": "Motor MA0064 (CV-M2205)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0064@2": { + "A": "0", + "B": "MA0064", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187122.9, + 285675.5 + ], + "IO": "MA0064", + "ID": "9999", + "VERW": "ILS-CV-M1205", + "BEZEICHNUNG": "Motor MA0064 (CV-M1205)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ7", + "TEXT-D": "Motor MA0064", + "TEXT-E": "Motor MA0064", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0064@5": { + "A": "0", + "B": "MA0064", + "C": "10064710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1 - HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220137.2, + 153407.1 + ], + "IO": "MA0064", + "ID": "9999", + "VERW": "ILS-CV M5004", + "BEZEICHNUNG": "Motor MA0064 (ILS-CV M5004)", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "Motor MA0064", + "TEXT-E": "Motor MA0064", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MA0064@4": { + "A": "0", + "B": "MA0064", + "C": "10073710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355588.8, + 741289.2 + ], + "IO": "MA0064", + "ID": "9999", + "VERW": "ILS-CV-M4007", + "BEZEICHNUNG": "Motor MA0064 (ILS-CV-M4007)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MA0064@1": { + "A": "0", + "B": "MA0064", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334141.4, + 161393.1 + ], + "IO": "MA0064", + "ID": "9999", + "VERW": "CV-M0106 0,55", + "BEZEICHNUNG": "Motor MA0064 (ILS-CV M0106)", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor MA0064", + "TEXT-E": "Motor MA0064", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0063@3": { + "A": "0", + "B": "MA0063", + "C": "20063710081010063939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205904.7, + 438560.0 + ], + "IO": "MA0063", + "ID": "9999", + "VERW": "KR-M2202 0,55", + "BEZEICHNUNG": "Motor MA0063 (KR-M2202)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0063@2": { + "A": "0", + "B": "MA0063", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206685.9, + 288747.3 + ], + "IO": "MA0063", + "ID": "9999", + "VERW": "ILS-KR M1202", + "BEZEICHNUNG": "Motor MA0063 (KR-M1202)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ7", + "TEXT-D": "Motor MA0063", + "TEXT-E": "Motor MA0063", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0063@5": { + "A": "0", + "B": "MA0063", + "C": "10063710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1 - HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219468.0, + 157276.7 + ], + "IO": "MA0063", + "ID": "9999", + "VERW": "ILS-CV M5003", + "BEZEICHNUNG": "Motor MA0063 (ILS-CV M5003)", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "Motor MA0063", + "TEXT-E": "Motor MA0063", + "TEXT-ES": "", + "TEXT-F": "4G1,5mm² 10m", + "SPS": "5" + }, + "MA0063@4": { + "A": "0", + "B": "MA0063", + "C": "10073710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 352012.6, + 740915.0 + ], + "IO": "MA0063", + "ID": "9999", + "VERW": "ILS-CV-M4006", + "BEZEICHNUNG": "Motor MA0063 (ILS-CV-M4006)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MA0063@1": { + "A": "0", + "B": "MA0063", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 333670.8, + 165079.8 + ], + "IO": "MA0063", + "ID": "9999", + "VERW": "CV-M0105 0,55", + "BEZEICHNUNG": "Motor MA0063 (ILS-CV-M0105)", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ3", + "TEXT-D": "Motor MA0063", + "TEXT-E": "Motor MA0063", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0200@3": { + "A": "0", + "B": "MA0200", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174505.2, + 420870.2 + ], + "IO": "MA0200", + "ID": "9999", + "VERW": "ILS-KR M2203", + "BEZEICHNUNG": "Motor MA0200 (KR-M2203)", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0200@2": { + "A": "0", + "B": "MA0200", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 169290.5, + 270874.0 + ], + "IO": "MA0200", + "ID": "9999", + "VERW": "ILS-KR-M1203", + "BEZEICHNUNG": "Motor MA0200 (KR-M1203)", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ3", + "TEXT-D": "Motor MA0200", + "TEXT-E": "Motor MA0200", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0201@3": { + "A": "0", + "B": "MA0201", + "C": "20201710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205935.1, + 420786.9 + ], + "IO": "MA0201", + "ID": "9999", + "VERW": "ILS-KR M2204", + "BEZEICHNUNG": "Motor MA0201 (KR-M2204)", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0201@2": { + "A": "0", + "B": "MA0201", + "C": "20201710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206675.7, + 270783.0 + ], + "IO": "MA0201", + "ID": "9999", + "VERW": "ILS-KR-M1204", + "BEZEICHNUNG": "Motor MA0201 (KR-M1204)", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0065@3": { + "A": "0", + "B": "MA0065", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204350.9, + 435637.8 + ], + "IO": "MA0065", + "ID": "9999", + "VERW": "CV-M2206 0,75", + "BEZEICHNUNG": "Motor MA0065 (CV-M2206)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0065@2": { + "A": "0", + "B": "MA0065", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204353.3, + 285634.7 + ], + "IO": "MA0065", + "ID": "9999", + "VERW": "ILS-CV M1206", + "BEZEICHNUNG": "Motor MA0065 (CV-M1206)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ7", + "TEXT-D": "Motor MA0065", + "TEXT-E": "Motor MA0065", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0065@5": { + "A": "0", + "B": "MA0065", + "C": "10065710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1 - HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223630.3, + 153310.6 + ], + "IO": "MA0065", + "ID": "9999", + "VERW": "ILS-CV M5005", + "BEZEICHNUNG": "Motor MA0065 (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "Motor MA0065", + "TEXT-E": "Motor MA0065", + "TEXT-ES": "", + "TEXT-F": "4G1,5 mm² 20m", + "SPS": "5" + }, + "MA0065@4": { + "A": "0", + "B": "MA0065", + "C": "10073710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 352012.6, + 750425.0 + ], + "IO": "MA0065", + "ID": "9999", + "VERW": "ILS-CV-M4008", + "BEZEICHNUNG": "Motor MA0065 (ILS-CV M4008)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MA0065@1": { + "A": "0", + "B": "MA0065", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337179.5, + 165110.1 + ], + "IO": "MA0065", + "ID": "9999", + "VERW": "CV-M0107 0,55", + "BEZEICHNUNG": "Motor MA0065 (ILS-CV-M0107)", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor MA0065", + "TEXT-E": "Motor MA0065", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0066@3": { + "A": "0", + "B": "MA0066", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206612.9, + 435546.2 + ], + "IO": "MA0066", + "ID": "9999", + "VERW": "CV-M2207 0,75", + "BEZEICHNUNG": "Motor MA0066 (CV-M2207)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0066@2": { + "A": "0", + "B": "MA0066", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206605.4, + 285540.5 + ], + "IO": "MA0066", + "ID": "9999", + "VERW": "ILS-CV M1207", + "BEZEICHNUNG": "Motor MA0066 (CV-M1207)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ7", + "TEXT-D": "Motor MA0066", + "TEXT-E": "Motor MA0066", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0066@5": { + "A": "0", + "B": "MA0066", + "C": "10066710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1 - HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227674.8, + 152989.1 + ], + "IO": "MA0066", + "ID": "9999", + "VERW": "ILS-CV M5006", + "BEZEICHNUNG": "Motor MA0066 (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "Motor MA0066", + "TEXT-E": "Motor MA0066", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MA0066@4": { + "A": "0", + "B": "MA0066", + "C": "10073710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355593.6, + 750859.9 + ], + "IO": "MA0066", + "ID": "9999", + "VERW": "ILS-CV-M4009", + "BEZEICHNUNG": "Motor MA0066 (ILS-CV-M4009)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MA0066@1": { + "A": "0", + "B": "MA0066", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 339670.8, + 165079.9 + ], + "IO": "MA0066", + "ID": "9999", + "VERW": "CV-M0109 0,55", + "BEZEICHNUNG": "Motor MA0066 (ILS-CV-M0109)", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor MA0066", + "TEXT-E": "Motor MA0066", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0067@3": { + "A": "0", + "B": "MA0067", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227613.0, + 435640.5 + ], + "IO": "MA0067", + "ID": "9999", + "VERW": "ILS-CV M2208", + "BEZEICHNUNG": "Motor MA0067 (CV-M2208)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0067@2": { + "A": "0", + "B": "MA0067", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227609.7, + 285653.1 + ], + "IO": "MA0067", + "ID": "9999", + "VERW": "ILS-CV M1208", + "BEZEICHNUNG": "Motor MA0067 (CV-M1208)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ7", + "TEXT-D": "Motor MA0067", + "TEXT-E": "Motor MA0067", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0067@5": { + "A": "0", + "B": "MA0067", + "C": "10067710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1 - HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232059.0, + 153040.5 + ], + "IO": "MA0067", + "ID": "9999", + "VERW": "ILS-CV M5007", + "BEZEICHNUNG": "Motor MA0067 (ILS-CV M5007)", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "Motor MA0067", + "TEXT-E": "Motor MA0067", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MA0067@1": { + "A": "0", + "B": "MA0067", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340352.5, + 161118.3 + ], + "IO": "MA0067", + "ID": "9999", + "VERW": "CV-M0110 0,55", + "BEZEICHNUNG": "Motor MA0067 (ILS-CV-M0110)", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor MA0067", + "TEXT-E": "Motor MA0067", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0202@3": { + "A": "0", + "B": "MA0202", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 169348.7, + 418624.9 + ], + "IO": "MA0202", + "ID": "9999", + "VERW": "ILS-KR M2301", + "BEZEICHNUNG": "Motor MA0202 (KR-M2301)", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0202@2": { + "A": "0", + "B": "MA0202", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 169285.6, + 268639.1 + ], + "IO": "MA0202", + "ID": "9999", + "VERW": "KR-M0202_0,55", + "BEZEICHNUNG": "Motor MA0202 (KR-M1301)", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0203@3": { + "A": "0", + "B": "MA0203", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205993.6, + 418605.5 + ], + "IO": "MA0203", + "ID": "9999", + "VERW": "ILS-KR M2302", + "BEZEICHNUNG": "Motor MA0203 (KR-M2302)", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0203@2": { + "A": "0", + "B": "MA0203", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206733.0, + 268600.1 + ], + "IO": "MA0203", + "ID": "9999", + "VERW": "KR-M0203_0,55", + "BEZEICHNUNG": "Motor MA0203 (KR-M1302)", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3110@3": { + "A": "0", + "B": "BG3110", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 457822.3 + ], + "IO": "BG3110", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.17", + "SPS": "3" + }, + "BG3110@2": { + "A": "0", + "B": "BG3110", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 307822.3 + ], + "IO": "BG3110", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.17", + "SPS": "2" + }, + "BG3107@3": { + "A": "0", + "B": "BG3107", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.1, + 457822.0 + ], + "IO": "BG3107", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.16", + "SPS": "3" + }, + "BG3107@2": { + "A": "0", + "B": "BG3107", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.1, + 307822.0 + ], + "IO": "BG3107", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.16", + "SPS": "2" + }, + "BG3106@3": { + "A": "0", + "B": "BG3106", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 457822.3 + ], + "IO": "BG3106", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.15", + "SPS": "3" + }, + "BG3106@2": { + "A": "0", + "B": "BG3106", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 307822.3 + ], + "IO": "BG3106", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.15", + "SPS": "2" + }, + "BG3105@3": { + "A": "0", + "B": "BG3105", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 457822.3 + ], + "IO": "BG3105", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.14", + "SPS": "3" + }, + "BG3105@2": { + "A": "0", + "B": "BG3105", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 307822.3 + ], + "IO": "BG3105", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.14", + "SPS": "2" + }, + "BG3150@3": { + "A": "0", + "B": "BG3150", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208400.0, + 457808.0 + ], + "IO": "BG3150", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.01", + "SPS": "3" + }, + "BG3150@2": { + "A": "0", + "B": "BG3150", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208400.0, + 307808.0 + ], + "IO": "BG3150", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.01", + "SPS": "2" + }, + "BG3151@3": { + "A": "0", + "B": "BG3151", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209200.0, + 457807.9 + ], + "IO": "BG3151", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.02", + "SPS": "3" + }, + "BG3151@2": { + "A": "0", + "B": "BG3151", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209200.0, + 307807.9 + ], + "IO": "BG3151", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.02", + "SPS": "2" + }, + "BG3152@3": { + "A": "0", + "B": "BG3152", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210000.0, + 457807.9 + ], + "IO": "BG3152", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.03", + "SPS": "3" + }, + "BG3152@2": { + "A": "0", + "B": "BG3152", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210000.0, + 307807.9 + ], + "IO": "BG3152", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.03", + "SPS": "2" + }, + "BG3153@3": { + "A": "0", + "B": "BG3153", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211146.1, + 457807.8 + ], + "IO": "BG3153", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.04", + "SPS": "3" + }, + "BG3153@2": { + "A": "0", + "B": "BG3153", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211146.1, + 307807.8 + ], + "IO": "BG3153", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.04", + "SPS": "2" + }, + "BG3154@3": { + "A": "0", + "B": "BG3154", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211946.1, + 457807.8 + ], + "IO": "BG3154", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.05", + "SPS": "3" + }, + "BG3154@2": { + "A": "0", + "B": "BG3154", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211946.1, + 307807.8 + ], + "IO": "BG3154", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.05", + "SPS": "2" + }, + "BG3155@3": { + "A": "0", + "B": "BG3155", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212746.1, + 457807.9 + ], + "IO": "BG3155", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.06", + "SPS": "3" + }, + "BG3155@2": { + "A": "0", + "B": "BG3155", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212746.1, + 307807.9 + ], + "IO": "BG3155", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.06", + "SPS": "2" + }, + "BG3156@3": { + "A": "0", + "B": "BG3156", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213545.3, + 457807.8 + ], + "IO": "BG3156", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.07", + "SPS": "3" + }, + "BG3156@2": { + "A": "0", + "B": "BG3156", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213545.3, + 307807.8 + ], + "IO": "BG3156", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.07", + "SPS": "2" + }, + "BG3157@3": { + "A": "0", + "B": "BG3157", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214346.1, + 457807.8 + ], + "IO": "BG3157", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.08", + "SPS": "3" + }, + "BG3157@2": { + "A": "0", + "B": "BG3157", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214346.1, + 307807.8 + ], + "IO": "BG3157", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.08", + "SPS": "2" + }, + "BG3160@3": { + "A": "0", + "B": "BG3160", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215146.1, + 457808.6 + ], + "IO": "BG3160", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.09", + "SPS": "3" + }, + "BG3160@2": { + "A": "0", + "B": "BG3160", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215146.1, + 307808.6 + ], + "IO": "BG3160", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.09", + "SPS": "2" + }, + "BG3095@3": { + "A": "0", + "B": "BG3095", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 457822.4 + ], + "IO": "BG3095", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.06", + "SPS": "3" + }, + "BG3095@2": { + "A": "0", + "B": "BG3095", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 307822.4 + ], + "IO": "BG3095", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.06", + "SPS": "2" + }, + "BG3094@3": { + "A": "0", + "B": "BG3094", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 457822.4 + ], + "IO": "BG3094", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.05", + "SPS": "3" + }, + "BG3094@2": { + "A": "0", + "B": "BG3094", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 307822.4 + ], + "IO": "BG3094", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.05", + "SPS": "2" + }, + "BG3093@3": { + "A": "0", + "B": "BG3093", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.1, + 457822.1 + ], + "IO": "BG3093", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.04", + "SPS": "3" + }, + "BG3093@2": { + "A": "0", + "B": "BG3093", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.1, + 307822.1 + ], + "IO": "BG3093", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.04", + "SPS": "2" + }, + "BG3092@3": { + "A": "0", + "B": "BG3092", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 457822.4 + ], + "IO": "BG3092", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.03", + "SPS": "3" + }, + "BG3092@2": { + "A": "0", + "B": "BG3092", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 307822.4 + ], + "IO": "BG3092", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.03", + "SPS": "2" + }, + "BG3091@3": { + "A": "0", + "B": "BG3091", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 457822.4 + ], + "IO": "BG3091", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.02", + "SPS": "3" + }, + "BG3091@2": { + "A": "0", + "B": "BG3091", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 307822.4 + ], + "IO": "BG3091", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.02", + "SPS": "2" + }, + "BG3090@3": { + "A": "0", + "B": "BG3090", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 457695.7 + ], + "IO": "BG3090", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.01", + "SPS": "3" + }, + "BG3090@2": { + "A": "0", + "B": "BG3090", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 307695.7 + ], + "IO": "BG3090", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.01", + "SPS": "2" + }, + "BG3096@3": { + "A": "0", + "B": "BG3096", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 457822.4 + ], + "IO": "BG3096", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.07", + "SPS": "3" + }, + "BG3096@2": { + "A": "0", + "B": "BG3096", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 307822.4 + ], + "IO": "BG3096", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.07", + "SPS": "2" + }, + "BG3097@3": { + "A": "0", + "B": "BG3097", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.2, + 457822.4 + ], + "IO": "BG3097", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.08", + "SPS": "3" + }, + "BG3097@2": { + "A": "0", + "B": "BG3097", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.2, + 307822.4 + ], + "IO": "BG3097", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.08", + "SPS": "2" + }, + "BG3104@3": { + "A": "0", + "B": "BG3104", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193100.2, + 457822.0 + ], + "IO": "BG3104", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.13", + "SPS": "3" + }, + "BG3104@2": { + "A": "0", + "B": "BG3104", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193100.2, + 307822.0 + ], + "IO": "BG3104", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.13", + "SPS": "2" + }, + "BG3103@3": { + "A": "0", + "B": "BG3103", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193900.1, + 457822.3 + ], + "IO": "BG3103", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.12", + "SPS": "3" + }, + "BG3103@2": { + "A": "0", + "B": "BG3103", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193900.1, + 307822.3 + ], + "IO": "BG3103", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.12", + "SPS": "2" + }, + "BG3102@3": { + "A": "0", + "B": "BG3102", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194700.1, + 457822.3 + ], + "IO": "BG3102", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.11", + "SPS": "3" + }, + "BG3102@2": { + "A": "0", + "B": "BG3102", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194700.1, + 307822.3 + ], + "IO": "BG3102", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.11", + "SPS": "2" + }, + "BG3101@3": { + "A": "0", + "B": "BG3101", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195500.2, + 457822.0 + ], + "IO": "BG3101", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.10", + "SPS": "3" + }, + "BG3101@2": { + "A": "0", + "B": "BG3101", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195500.2, + 307822.0 + ], + "IO": "BG3101", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.10", + "SPS": "2" + }, + "BG3100@3": { + "A": "0", + "B": "BG3100", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196300.1, + 457822.3 + ], + "IO": "BG3100", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.09", + "SPS": "3" + }, + "BG3100@2": { + "A": "0", + "B": "BG3100", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196300.1, + 307822.3 + ], + "IO": "BG3100", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.09", + "SPS": "2" + }, + "BG3052@3": { + "A": "0", + "B": "BG3052", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.1, + 457822.0 + ], + "IO": "BG3052", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.19 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.19", + "SPS": "3" + }, + "BG3052@2": { + "A": "0", + "B": "BG3052", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.1, + 307822.0 + ], + "IO": "BG3052", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.19 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.19", + "SPS": "2" + }, + "BG3051@3": { + "A": "0", + "B": "BG3051", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 457822.3 + ], + "IO": "BG3051", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.18 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.18", + "SPS": "3" + }, + "BG3051@2": { + "A": "0", + "B": "BG3051", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 307822.3 + ], + "IO": "BG3051", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.18 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.18", + "SPS": "2" + }, + "BG3050@3": { + "A": "0", + "B": "BG3050", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 457822.3 + ], + "IO": "BG3050", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.17", + "SPS": "3" + }, + "BG3050@2": { + "A": "0", + "B": "BG3050", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 307822.3 + ], + "IO": "BG3050", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.17", + "SPS": "2" + }, + "BG3047@3": { + "A": "0", + "B": "BG3047", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.1, + 457822.0 + ], + "IO": "BG3047", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.16", + "SPS": "3" + }, + "BG3047@2": { + "A": "0", + "B": "BG3047", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.1, + 307822.0 + ], + "IO": "BG3047", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.16", + "SPS": "2" + }, + "BG3046@3": { + "A": "0", + "B": "BG3046", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 457822.3 + ], + "IO": "BG3046", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.15", + "SPS": "3" + }, + "BG3046@2": { + "A": "0", + "B": "BG3046", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 307822.3 + ], + "IO": "BG3046", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.15", + "SPS": "2" + }, + "BG3045@3": { + "A": "0", + "B": "BG3045", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 457822.3 + ], + "IO": "BG3045", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.14", + "SPS": "3" + }, + "BG3045@2": { + "A": "0", + "B": "BG3045", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 307822.3 + ], + "IO": "BG3045", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.14", + "SPS": "2" + }, + "BG3044@3": { + "A": "0", + "B": "BG3044", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175150.0, + 457822.0 + ], + "IO": "BG3044", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.13", + "SPS": "3" + }, + "BG3044@2": { + "A": "0", + "B": "BG3044", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175150.0, + 307822.0 + ], + "IO": "BG3044", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.13", + "SPS": "2" + }, + "BG3043@3": { + "A": "0", + "B": "BG3043", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 457822.3 + ], + "IO": "BG3043", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.12", + "SPS": "3" + }, + "BG3043@2": { + "A": "0", + "B": "BG3043", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 307822.3 + ], + "IO": "BG3043", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.12", + "SPS": "2" + }, + "BG3042@3": { + "A": "0", + "B": "BG3042", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 457822.3 + ], + "IO": "BG3042", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.11", + "SPS": "3" + }, + "BG3042@2": { + "A": "0", + "B": "BG3042", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 307822.3 + ], + "IO": "BG3042", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.11", + "SPS": "2" + }, + "BG3041@3": { + "A": "0", + "B": "BG3041", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177550.0, + 457822.0 + ], + "IO": "BG3041", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.10", + "SPS": "3" + }, + "BG3041@2": { + "A": "0", + "B": "BG3041", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177550.0, + 307822.0 + ], + "IO": "BG3041", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.10", + "SPS": "2" + }, + "BG3040@3": { + "A": "0", + "B": "BG3040", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 457822.3 + ], + "IO": "BG3040", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.09", + "SPS": "3" + }, + "BG3040@2": { + "A": "0", + "B": "BG3040", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 307822.3 + ], + "IO": "BG3040", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.09", + "SPS": "2" + }, + "BG3037@3": { + "A": "0", + "B": "BG3037", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 457822.3 + ], + "IO": "BG3037", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.08", + "SPS": "3" + }, + "BG3037@2": { + "A": "0", + "B": "BG3037", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 307822.3 + ], + "IO": "BG3037", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.08", + "SPS": "2" + }, + "BG3036@3": { + "A": "0", + "B": "BG3036", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 457822.0 + ], + "IO": "BG3036", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.07", + "SPS": "3" + }, + "BG3036@2": { + "A": "0", + "B": "BG3036", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 307822.0 + ], + "IO": "BG3036", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.07", + "SPS": "2" + }, + "BG3035@3": { + "A": "0", + "B": "BG3035", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.9, + 457822.3 + ], + "IO": "BG3035", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.06", + "SPS": "3" + }, + "BG3035@2": { + "A": "0", + "B": "BG3035", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.9, + 307822.3 + ], + "IO": "BG3035", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.06", + "SPS": "2" + }, + "BG3034@3": { + "A": "0", + "B": "BG3034", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.9, + 457822.3 + ], + "IO": "BG3034", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.05", + "SPS": "3" + }, + "BG3034@2": { + "A": "0", + "B": "BG3034", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.9, + 307822.3 + ], + "IO": "BG3034", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.05", + "SPS": "2" + }, + "BG3033@3": { + "A": "0", + "B": "BG3033", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 457822.0 + ], + "IO": "BG3033", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.04", + "SPS": "3" + }, + "BG3033@2": { + "A": "0", + "B": "BG3033", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 307822.0 + ], + "IO": "BG3033", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.04", + "SPS": "2" + }, + "BG3032@3": { + "A": "0", + "B": "BG3032", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184349.9, + 457822.3 + ], + "IO": "BG3032", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.03", + "SPS": "3" + }, + "BG3032@2": { + "A": "0", + "B": "BG3032", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184349.9, + 307822.3 + ], + "IO": "BG3032", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.03", + "SPS": "2" + }, + "BG3031@3": { + "A": "0", + "B": "BG3031", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 457822.3 + ], + "IO": "BG3031", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.02", + "SPS": "3" + }, + "BG3031@2": { + "A": "0", + "B": "BG3031", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 307822.3 + ], + "IO": "BG3031", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.02", + "SPS": "2" + }, + "BG3030@3": { + "A": "0", + "B": "BG3030", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.3, + 457695.7 + ], + "IO": "BG3030", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.1.01", + "SPS": "3" + }, + "BG3030@2": { + "A": "0", + "B": "BG3030", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.3, + 307695.7 + ], + "IO": "BG3030", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.1.01", + "SPS": "2" + }, + "BG3161@3": { + "A": "0", + "B": "BG3161", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217150.0, + 457807.7 + ], + "IO": "BG3161", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.10", + "SPS": "3" + }, + "BG3161@2": { + "A": "0", + "B": "BG3161", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217150.0, + 307807.7 + ], + "IO": "BG3161", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.10", + "SPS": "2" + }, + "BG3162@3": { + "A": "0", + "B": "BG3162", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217950.0, + 457807.7 + ], + "IO": "BG3162", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.11", + "SPS": "3" + }, + "BG3162@2": { + "A": "0", + "B": "BG3162", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217950.0, + 307807.7 + ], + "IO": "BG3162", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.11", + "SPS": "2" + }, + "BG3163@3": { + "A": "0", + "B": "BG3163", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218750.0, + 457807.6 + ], + "IO": "BG3163", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.12", + "SPS": "3" + }, + "BG3163@2": { + "A": "0", + "B": "BG3163", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218750.0, + 307807.6 + ], + "IO": "BG3163", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.12", + "SPS": "2" + }, + "BG3164@3": { + "A": "0", + "B": "BG3164", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219549.1, + 457807.6 + ], + "IO": "BG3164", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.13", + "SPS": "3" + }, + "BG3164@2": { + "A": "0", + "B": "BG3164", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219549.1, + 307807.6 + ], + "IO": "BG3164", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.13", + "SPS": "2" + }, + "BG3165@3": { + "A": "0", + "B": "BG3165", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220350.0, + 457807.6 + ], + "IO": "BG3165", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.14", + "SPS": "3" + }, + "BG3165@2": { + "A": "0", + "B": "BG3165", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220350.0, + 307807.6 + ], + "IO": "BG3165", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.14", + "SPS": "2" + }, + "BG3166@3": { + "A": "0", + "B": "BG3166", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221150.0, + 457807.7 + ], + "IO": "BG3166", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.15", + "SPS": "3" + }, + "BG3166@2": { + "A": "0", + "B": "BG3166", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221150.0, + 307807.7 + ], + "IO": "BG3166", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.15", + "SPS": "2" + }, + "BG3167@3": { + "A": "0", + "B": "BG3167", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221950.0, + 457807.6 + ], + "IO": "BG3167", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.16", + "SPS": "3" + }, + "BG3167@2": { + "A": "0", + "B": "BG3167", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221950.0, + 307807.6 + ], + "IO": "BG3167", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.16", + "SPS": "2" + }, + "BG3170@3": { + "A": "0", + "B": "BG3170", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223150.0, + 457807.6 + ], + "IO": "BG3170", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.17", + "SPS": "3" + }, + "BG3170@2": { + "A": "0", + "B": "BG3170", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223150.0, + 307807.6 + ], + "IO": "BG3170", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.17", + "SPS": "2" + }, + "BG3171@3": { + "A": "0", + "B": "BG3171", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223950.0, + 457807.7 + ], + "IO": "BG3171", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.18 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.18", + "SPS": "3" + }, + "BG3171@2": { + "A": "0", + "B": "BG3171", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223950.0, + 307807.7 + ], + "IO": "BG3171", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.18 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.18", + "SPS": "2" + }, + "BG3172@3": { + "A": "0", + "B": "BG3172", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224748.4, + 457807.6 + ], + "IO": "BG3172", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.19 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.19", + "SPS": "3" + }, + "BG3172@2": { + "A": "0", + "B": "BG3172", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224748.4, + 307807.6 + ], + "IO": "BG3172", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.19 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.19", + "SPS": "2" + }, + "BG3174@3": { + "A": "0", + "B": "BG3174", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226350.0, + 457807.7 + ], + "IO": "BG3174", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.21 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.21", + "SPS": "3" + }, + "BG3174@2": { + "A": "0", + "B": "BG3174", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226350.0, + 307807.7 + ], + "IO": "BG3174", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.21 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.21", + "SPS": "2" + }, + "BG3180@3": { + "A": "0", + "B": "BG3180", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227619.3, + 457857.7 + ], + "IO": "BG3180", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3180@2": { + "A": "0", + "B": "BG3180", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227619.3, + 307857.7 + ], + "IO": "BG3180", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3184@3": { + "A": "0", + "B": "BG3184", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227614.4, + 457275.6 + ], + "IO": "BG3184", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3184@2": { + "A": "0", + "B": "BG3184", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227614.4, + 307275.6 + ], + "IO": "BG3184", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3185@3": { + "A": "0", + "B": "BG3185", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227612.7, + 456964.4 + ], + "IO": "BG3185", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K2102 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3185@2": { + "A": "0", + "B": "BG3185", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227612.7, + 306964.4 + ], + "IO": "BG3185", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K1102 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3181@3": { + "A": "0", + "B": "BG3181", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227916.3, + 458837.5 + ], + "IO": "BG3181", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2102 ) Block 2.1.4", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3181@2": { + "A": "0", + "B": "BG3181", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227916.3, + 308837.5 + ], + "IO": "BG3181", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1102 ) Block 1.1.4", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3182@3": { + "A": "0", + "B": "BG3182", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228219.5, + 459133.9 + ], + "IO": "BG3182", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K2102 Einfahrt Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3182@2": { + "A": "0", + "B": "BG3182", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228219.5, + 309133.9 + ], + "IO": "BG3182", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1102 Einfahrt Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3210@3": { + "A": "0", + "B": "BG3210", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 457808.0 + ], + "IO": "BG3210", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.01", + "SPS": "3" + }, + "BG3210@2": { + "A": "0", + "B": "BG3210", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 307808.0 + ], + "IO": "BG3210", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.01", + "SPS": "2" + }, + "BG3211@3": { + "A": "0", + "B": "BG3211", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 457807.9 + ], + "IO": "BG3211", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.02", + "SPS": "3" + }, + "BG3211@2": { + "A": "0", + "B": "BG3211", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 307807.9 + ], + "IO": "BG3211", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.02", + "SPS": "2" + }, + "BG3212@3": { + "A": "0", + "B": "BG3212", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 457807.9 + ], + "IO": "BG3212", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.03", + "SPS": "3" + }, + "BG3212@2": { + "A": "0", + "B": "BG3212", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 307807.9 + ], + "IO": "BG3212", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.03", + "SPS": "2" + }, + "BG3213@3": { + "A": "0", + "B": "BG3213", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 457807.8 + ], + "IO": "BG3213", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.04", + "SPS": "3" + }, + "BG3213@2": { + "A": "0", + "B": "BG3213", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 307807.8 + ], + "IO": "BG3213", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.04", + "SPS": "2" + }, + "BG3214@3": { + "A": "0", + "B": "BG3214", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 457807.8 + ], + "IO": "BG3214", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.05", + "SPS": "3" + }, + "BG3214@2": { + "A": "0", + "B": "BG3214", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 307807.8 + ], + "IO": "BG3214", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.05", + "SPS": "2" + }, + "BG3215@3": { + "A": "0", + "B": "BG3215", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 457807.9 + ], + "IO": "BG3215", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.06", + "SPS": "3" + }, + "BG3215@2": { + "A": "0", + "B": "BG3215", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 307807.9 + ], + "IO": "BG3215", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.06", + "SPS": "2" + }, + "BG3216@3": { + "A": "0", + "B": "BG3216", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233949.1, + 457807.8 + ], + "IO": "BG3216", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.07", + "SPS": "3" + }, + "BG3216@2": { + "A": "0", + "B": "BG3216", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233949.1, + 307807.8 + ], + "IO": "BG3216", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.07", + "SPS": "2" + }, + "BG3217@3": { + "A": "0", + "B": "BG3217", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 457808.6 + ], + "IO": "BG3217", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.08", + "SPS": "3" + }, + "BG3217@2": { + "A": "0", + "B": "BG3217", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 307808.6 + ], + "IO": "BG3217", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.08", + "SPS": "2" + }, + "BG3221@3": { + "A": "0", + "B": "BG3221", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 457807.7 + ], + "IO": "BG3221", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.10", + "SPS": "3" + }, + "BG3221@2": { + "A": "0", + "B": "BG3221", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 307807.7 + ], + "IO": "BG3221", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.10", + "SPS": "2" + }, + "BG3222@3": { + "A": "0", + "B": "BG3222", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 457807.7 + ], + "IO": "BG3222", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.11", + "SPS": "3" + }, + "BG3222@2": { + "A": "0", + "B": "BG3222", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 307807.7 + ], + "IO": "BG3222", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.11", + "SPS": "2" + }, + "BG3223@3": { + "A": "0", + "B": "BG3223", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 457807.6 + ], + "IO": "BG3223", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.12", + "SPS": "3" + }, + "BG3223@2": { + "A": "0", + "B": "BG3223", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 307807.6 + ], + "IO": "BG3223", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.12", + "SPS": "2" + }, + "BG3224@3": { + "A": "0", + "B": "BG3224", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239149.1, + 457807.6 + ], + "IO": "BG3224", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.13", + "SPS": "3" + }, + "BG3224@2": { + "A": "0", + "B": "BG3224", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239149.1, + 307807.6 + ], + "IO": "BG3224", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.13", + "SPS": "2" + }, + "BG3220@3": { + "A": "0", + "B": "BG3220", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 457808.6 + ], + "IO": "BG3220", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.09", + "SPS": "3" + }, + "BG3220@2": { + "A": "0", + "B": "BG3220", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 307808.6 + ], + "IO": "BG3220", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.09", + "SPS": "2" + }, + "BG3194@3": { + "A": "0", + "B": "BG3194", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241352.5, + 459590.7 + ], + "IO": "BG3194", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2102 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3242@3": { + "A": "0", + "B": "BG3242", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186431.0, + 442042.8 + ], + "IO": "BG3242", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2103 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3242@2": { + "A": "0", + "B": "BG3242", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186431.0, + 292042.8 + ], + "IO": "BG3242", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1103 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3242@5": { + "A": "0", + "B": "BG3242", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217034.5, + 151893.5 + ], + "IO": "BG3242", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "5" + }, + "BG3242@4": { + "A": "0", + "B": "BG3242", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 378153.0, + 750860.4 + ], + "IO": "BG3242", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M4001)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3242@1": { + "A": "0", + "B": "BG3242", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 341906.1, + 164861.9 + ], + "IO": "BG3242", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M0100)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG3303@3": { + "A": "0", + "B": "BG3303", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204431.1, + 443231.9 + ], + "IO": "BG3303", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2106) ", + "KENNZEICHNUNG": "=A01+UC0302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3303@2": { + "A": "0", + "B": "BG3303", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204502.9, + 293172.8 + ], + "IO": "BG3303", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (Block 1.1.2) ", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3303@5": { + "A": "0", + "B": "BG3303", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224879.8, + 148296.3 + ], + "IO": "BG3303", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS CV-M5001)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "5" + }, + "BG3303@4": { + "A": "0", + "B": "BG3303", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356396.7, + 725377.9 + ], + "IO": "BG3303", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (AMR KR-M4003)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3304@3": { + "A": "0", + "B": "BG3304", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204428.4, + 442653.9 + ], + "IO": "BG3304", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2106) ", + "KENNZEICHNUNG": "=A01+UC0302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3304@2": { + "A": "0", + "B": "BG3304", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204500.2, + 292607.9 + ], + "IO": "BG3304", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1106 Block 1.1.2) ", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3304@5": { + "A": "0", + "B": "BG3304", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222532.5, + 148777.6 + ], + "IO": "BG3304", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS CV-M5001)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 15m", + "SPS": "5" + }, + "BG3304@4": { + "A": "0", + "B": "BG3304", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356209.0, + 727409.8 + ], + "IO": "BG3304", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator vor MPS 3 (AMR KR-M4003)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3304@1": { + "A": "0", + "B": "BG3304", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331977.1, + 152700.3 + ], + "IO": "BG3304", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3301@3": { + "A": "0", + "B": "BG3301", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204428.4, + 442357.8 + ], + "IO": "BG3301", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2106) ", + "KENNZEICHNUNG": "=A01+UC0302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3301@2": { + "A": "0", + "B": "BG3301", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204500.2, + 292318.1 + ], + "IO": "BG3301", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1106 Block 1.1.2) ", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3301@5": { + "A": "0", + "B": "BG3301", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224376.1, + 149841.1 + ], + "IO": "BG3301", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS CV-M5000)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 15m", + "SPS": "5" + }, + "BG3301@4": { + "A": "0", + "B": "BG3301", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358561.3, + 736492.4 + ], + "IO": "BG3301", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 6 (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3300@3": { + "A": "0", + "B": "BG3300", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203430.1, + 441083.0 + ], + "IO": "BG3300", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (KR-M2103 Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3300@2": { + "A": "0", + "B": "BG3300", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203430.1, + 291083.0 + ], + "IO": "BG3300", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3300@5": { + "A": "0", + "B": "BG3300", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225961.4, + 149696.4 + ], + "IO": "BG3300", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS CV-M5000)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "5" + }, + "BG3300@4": { + "A": "0", + "B": "BG3300", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358556.7, + 725734.7 + ], + "IO": "BG3300", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (AMR KR-M4003)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3302@3": { + "A": "0", + "B": "BG3302", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203631.0, + 442042.7 + ], + "IO": "BG3302", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2103 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3302@2": { + "A": "0", + "B": "BG3302", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203631.0, + 292042.7 + ], + "IO": "BG3302", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1103 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3302@5": { + "A": "0", + "B": "BG3302", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222261.4, + 150904.0 + ], + "IO": "BG3302", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "5" + }, + "BG3336@3": { + "A": "0", + "B": "BG3336", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 442667.6 + ], + "IO": "BG3336", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.07", + "SPS": "3" + }, + "BG3336@2": { + "A": "0", + "B": "BG3336", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 292667.6 + ], + "IO": "BG3336", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.07", + "SPS": "2" + }, + "BG3335@3": { + "A": "0", + "B": "BG3335", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 442667.6 + ], + "IO": "BG3335", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.06", + "SPS": "3" + }, + "BG3335@2": { + "A": "0", + "B": "BG3335", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 292667.6 + ], + "IO": "BG3335", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.06", + "SPS": "2" + }, + "BG3335@5": { + "A": "0", + "B": "BG3335", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241245.6, + 302941.3 + ], + "IO": "BG3335", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M5001) ", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3335@1": { + "A": "0", + "B": "BG3335", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340147.1, + 152181.2 + ], + "IO": "BG3335", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG3334@3": { + "A": "0", + "B": "BG3334", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 442667.6 + ], + "IO": "BG3334", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.05", + "SPS": "3" + }, + "BG3334@2": { + "A": "0", + "B": "BG3334", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 292667.6 + ], + "IO": "BG3334", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.05", + "SPS": "2" + }, + "BG3334@5": { + "A": "0", + "B": "BG3334", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241248.3, + 302674.7 + ], + "IO": "BG3334", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M5001)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3334@1": { + "A": "0", + "B": "BG3334", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340330.7, + 153418.1 + ], + "IO": "BG3334", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 4 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3333@3": { + "A": "0", + "B": "BG3333", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.0, + 442667.6 + ], + "IO": "BG3333", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.04", + "SPS": "3" + }, + "BG3333@2": { + "A": "0", + "B": "BG3333", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.0, + 292667.6 + ], + "IO": "BG3333", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.04", + "SPS": "2" + }, + "BG3333@5": { + "A": "0", + "B": "BG3333", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241245.6, + 302055.1 + ], + "IO": "BG3333", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M5001) ", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3332@3": { + "A": "0", + "B": "BG3332", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 442667.6 + ], + "IO": "BG3332", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.03", + "SPS": "3" + }, + "BG3332@2": { + "A": "0", + "B": "BG3332", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 292667.6 + ], + "IO": "BG3332", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.03", + "SPS": "2" + }, + "BG3332@5": { + "A": "0", + "B": "BG3332", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243203.2, + 303583.2 + ], + "IO": "BG3332", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M5000) ", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3332@1": { + "A": "0", + "B": "BG3332", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 338655.7, + 152427.8 + ], + "IO": "BG3332", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG3331@3": { + "A": "0", + "B": "BG3331", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 442667.6 + ], + "IO": "BG3331", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.02", + "SPS": "3" + }, + "BG3331@2": { + "A": "0", + "B": "BG3331", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 292667.6 + ], + "IO": "BG3331", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.02", + "SPS": "2" + }, + "BG3331@5": { + "A": "0", + "B": "BG3331", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243205.9, + 303316.4 + ], + "IO": "BG3331", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M5000)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3331@1": { + "A": "0", + "B": "BG3331", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 338558.8, + 153731.6 + ], + "IO": "BG3331", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor1", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 5m", + "SPS": "1" + }, + "BG3330@3": { + "A": "0", + "B": "BG3330", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 442667.6 + ], + "IO": "BG3330", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.01", + "SPS": "3" + }, + "BG3330@2": { + "A": "0", + "B": "BG3330", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 292667.6 + ], + "IO": "BG3330", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.01", + "SPS": "2" + }, + "BG3330@5": { + "A": "0", + "B": "BG3330", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243203.2, + 302710.2 + ], + "IO": "BG3330", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M0510) ", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3330@1": { + "A": "0", + "B": "BG3330", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337870.1, + 152700.3 + ], + "IO": "BG3330", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 3 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 5m", + "SPS": "1" + }, + "BG3343@3": { + "A": "0", + "B": "BG3343", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193900.0, + 442667.6 + ], + "IO": "BG3343", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.12", + "SPS": "3" + }, + "BG3343@2": { + "A": "0", + "B": "BG3343", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193900.0, + 292667.6 + ], + "IO": "BG3343", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.12", + "SPS": "2" + }, + "BG3343@1": { + "A": "0", + "B": "BG3343", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370715.4, + 178268.7 + ], + "IO": "BG3343", + "ID": "", + "VERW": "LS aus", + "BEZEICHNUNG": "LS Endlage ausgefahren ", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI3", + "TEXT-D": "LS Endlage ausgefahren ", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "BG3342@3": { + "A": "0", + "B": "BG3342", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194700.0, + 442667.6 + ], + "IO": "BG3342", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.11", + "SPS": "3" + }, + "BG3342@2": { + "A": "0", + "B": "BG3342", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194700.0, + 292667.6 + ], + "IO": "BG3342", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.11", + "SPS": "2" + }, + "BG3342@1": { + "A": "0", + "B": "BG3342", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "Sesnor induktiv bündiger Einbau M18/8mm", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 343950.4, + 151913.5 + ], + "IO": "BG3342", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 15m", + "SPS": "1" + }, + "BG3341@3": { + "A": "0", + "B": "BG3341", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195500.0, + 442667.6 + ], + "IO": "BG3341", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.10", + "SPS": "3" + }, + "BG3341@2": { + "A": "0", + "B": "BG3341", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195500.0, + 292667.6 + ], + "IO": "BG3341", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.10", + "SPS": "2" + }, + "BG3341@1": { + "A": "0", + "B": "BG3341", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 343066.4, + 151902.1 + ], + "IO": "BG3341", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 5 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "1" + }, + "BG3340@3": { + "A": "0", + "B": "BG3340", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196300.0, + 442667.6 + ], + "IO": "BG3340", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.09", + "SPS": "3" + }, + "BG3340@2": { + "A": "0", + "B": "BG3340", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196300.0, + 292667.6 + ], + "IO": "BG3340", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.09", + "SPS": "2" + }, + "BG3340@1": { + "A": "0", + "B": "BG3340", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 342925.4, + 153802.7 + ], + "IO": "BG3340", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS-CV M4104)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "1" + }, + "BG3337@3": { + "A": "0", + "B": "BG3337", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.0, + 442667.6 + ], + "IO": "BG3337", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.08", + "SPS": "3" + }, + "BG3337@2": { + "A": "0", + "B": "BG3337", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.0, + 292667.6 + ], + "IO": "BG3337", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.08", + "SPS": "2" + }, + "BG3337@1": { + "A": "0", + "B": "BG3337", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 342176.9, + 153712.2 + ], + "IO": "BG3337", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 15m", + "SPS": "1" + }, + "BG3344@3": { + "A": "0", + "B": "BG3344", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193100.0, + 442667.6 + ], + "IO": "BG3344", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.13", + "SPS": "3" + }, + "BG3344@2": { + "A": "0", + "B": "BG3344", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193100.0, + 292667.6 + ], + "IO": "BG3344", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.13", + "SPS": "2" + }, + "BG3344@1": { + "A": "0", + "B": "BG3344", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370715.4, + 178538.7 + ], + "IO": "BG3344", + "ID": "", + "VERW": "LS ein", + "BEZEICHNUNG": "LS Endlage eingefahren ", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI3", + "TEXT-D": "LS Endlage eingefahren ", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "BG3346@3": { + "A": "0", + "B": "BG3346", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 442667.6 + ], + "IO": "BG3346", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.15", + "SPS": "3" + }, + "BG3346@2": { + "A": "0", + "B": "BG3346", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 292667.6 + ], + "IO": "BG3346", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.15", + "SPS": "2" + }, + "BG3346@1": { + "A": "0", + "B": "BG3346", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376715.4, + 178537.9 + ], + "IO": "BG3346", + "ID": "", + "VERW": "LS ein", + "BEZEICHNUNG": "LS Endlage eingefahren ", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI3", + "TEXT-D": "LS Endlage eingefahren ", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "BG3345@3": { + "A": "0", + "B": "BG3345", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 442667.6 + ], + "IO": "BG3345", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.14", + "SPS": "3" + }, + "BG3345@2": { + "A": "0", + "B": "BG3345", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 292667.6 + ], + "IO": "BG3345", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.14", + "SPS": "2" + }, + "BG3345@1": { + "A": "0", + "B": "BG3345", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376715.4, + 178267.9 + ], + "IO": "BG3345", + "ID": "", + "VERW": "LS aus", + "BEZEICHNUNG": "LS Endlage ausgefahren ", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI3", + "TEXT-D": "LS Endlage ausgefahren ", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "BG3347@3": { + "A": "0", + "B": "BG3347", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.0, + 442667.6 + ], + "IO": "BG3347", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.16", + "SPS": "3" + }, + "BG3347@2": { + "A": "0", + "B": "BG3347", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.0, + 292667.6 + ], + "IO": "BG3347", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.16", + "SPS": "2" + }, + "BG3350@3": { + "A": "0", + "B": "BG3350", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 442667.6 + ], + "IO": "BG3350", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.2.17", + "SPS": "3" + }, + "BG3350@2": { + "A": "0", + "B": "BG3350", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 292667.6 + ], + "IO": "BG3350", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.2.17", + "SPS": "2" + }, + "BG3363@3": { + "A": "0", + "B": "BG3363", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206542.9, + 443176.2 + ], + "IO": "BG3363", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2107) ", + "KENNZEICHNUNG": "=A01+UC0303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3363@2": { + "A": "0", + "B": "BG3363", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206542.9, + 293172.8 + ], + "IO": "BG3363", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1107)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3363@5": { + "A": "0", + "B": "BG3363", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225303.1, + 155330.7 + ], + "IO": "BG3363", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3363@4": { + "A": "0", + "B": "BG3363", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356336.6, + 739165.7 + ], + "IO": "BG3363", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3364@3": { + "A": "0", + "B": "BG3364", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206540.2, + 442613.2 + ], + "IO": "BG3364", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2107)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3364@2": { + "A": "0", + "B": "BG3364", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206540.2, + 292607.9 + ], + "IO": "BG3364", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1107) ", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3364@5": { + "A": "0", + "B": "BG3364", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225298.5, + 155647.9 + ], + "IO": "BG3364", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3361@3": { + "A": "0", + "B": "BG3361", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206540.2, + 442318.1 + ], + "IO": "BG3361", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2107)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3361@2": { + "A": "0", + "B": "BG3361", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206540.2, + 292318.1 + ], + "IO": "BG3361", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1107) ", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3361@5": { + "A": "0", + "B": "BG3361", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226560.7, + 151995.4 + ], + "IO": "BG3361", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3362@3": { + "A": "0", + "B": "BG3362", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207312.3, + 442058.0 + ], + "IO": "BG3362", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2104 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3362@2": { + "A": "0", + "B": "BG3362", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207431.0, + 292042.7 + ], + "IO": "BG3362", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1104 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3362@5": { + "A": "0", + "B": "BG3362", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225298.5, + 154773.6 + ], + "IO": "BG3362", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3362@4": { + "A": "0", + "B": "BG3362", + "C": "10074500081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359583.0, + 737534.8 + ], + "IO": "BG3362", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 5 (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3360@3": { + "A": "0", + "B": "BG3360", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207829.4, + 441184.8 + ], + "IO": "BG3360", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3360@2": { + "A": "0", + "B": "BG3360", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207893.0, + 291191.5 + ], + "IO": "BG3360", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3360@5": { + "A": "0", + "B": "BG3360", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225042.0, + 152190.6 + ], + "IO": "BG3360", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator(ILS-KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3360@4": { + "A": "0", + "B": "BG3360", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358297.5, + 738267.2 + ], + "IO": "BG3360", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3390@3": { + "A": "0", + "B": "BG3390", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208400.0, + 442667.6 + ], + "IO": "BG3390", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.01", + "SPS": "3" + }, + "BG3390@2": { + "A": "0", + "B": "BG3390", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208400.0, + 292667.6 + ], + "IO": "BG3390", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.01", + "SPS": "2" + }, + "BG3390@4": { + "A": "0", + "B": "BG3390", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358779.7, + 743254.3 + ], + "IO": "BG3390", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (AMR ILS-CV M4002)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3391@3": { + "A": "0", + "B": "BG3391", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209200.0, + 442667.6 + ], + "IO": "BG3391", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.02", + "SPS": "3" + }, + "BG3391@2": { + "A": "0", + "B": "BG3391", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209200.0, + 292667.6 + ], + "IO": "BG3391", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.02", + "SPS": "2" + }, + "BG3391@4": { + "A": "0", + "B": "BG3391", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359609.5, + 743769.1 + ], + "IO": "BG3391", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (AMR ILS-CV M4010)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3392@3": { + "A": "0", + "B": "BG3392", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210000.0, + 442667.6 + ], + "IO": "BG3392", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.03", + "SPS": "3" + }, + "BG3392@2": { + "A": "0", + "B": "BG3392", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210000.0, + 292667.6 + ], + "IO": "BG3392", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.03", + "SPS": "2" + }, + "BG3392@4": { + "A": "0", + "B": "BG3392", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359583.1, + 744859.2 + ], + "IO": "BG3392", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4010)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3393@3": { + "A": "0", + "B": "BG3393", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211150.0, + 442667.6 + ], + "IO": "BG3393", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.04", + "SPS": "3" + }, + "BG3393@2": { + "A": "0", + "B": "BG3393", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211150.0, + 292667.6 + ], + "IO": "BG3393", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.04", + "SPS": "2" + }, + "BG3393@4": { + "A": "0", + "B": "BG3393", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359596.3, + 744443.4 + ], + "IO": "BG3393", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4010)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3394@3": { + "A": "0", + "B": "BG3394", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211950.0, + 442667.6 + ], + "IO": "BG3394", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.05", + "SPS": "3" + }, + "BG3394@2": { + "A": "0", + "B": "BG3394", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211950.0, + 292667.6 + ], + "IO": "BG3394", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.05", + "SPS": "2" + }, + "BG3395@3": { + "A": "0", + "B": "BG3395", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212750.0, + 442667.6 + ], + "IO": "BG3395", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.06", + "SPS": "3" + }, + "BG3395@2": { + "A": "0", + "B": "BG3395", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212750.0, + 292667.6 + ], + "IO": "BG3395", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.06", + "SPS": "2" + }, + "BG3396@3": { + "A": "0", + "B": "BG3396", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213550.0, + 442667.6 + ], + "IO": "BG3396", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.07", + "SPS": "3" + }, + "BG3396@2": { + "A": "0", + "B": "BG3396", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213550.0, + 292667.6 + ], + "IO": "BG3396", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.07", + "SPS": "2" + }, + "BG3397@3": { + "A": "0", + "B": "BG3397", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214350.0, + 442667.6 + ], + "IO": "BG3397", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.08", + "SPS": "3" + }, + "BG3397@2": { + "A": "0", + "B": "BG3397", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214350.0, + 292667.6 + ], + "IO": "BG3397", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.08", + "SPS": "2" + }, + "BG3400@3": { + "A": "0", + "B": "BG3400", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215150.0, + 442667.6 + ], + "IO": "BG3400", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.09", + "SPS": "3" + }, + "BG3400@2": { + "A": "0", + "B": "BG3400", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215150.0, + 292667.6 + ], + "IO": "BG3400", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.09", + "SPS": "2" + }, + "BG3401@3": { + "A": "0", + "B": "BG3401", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217150.0, + 442667.6 + ], + "IO": "BG3401", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.10", + "SPS": "3" + }, + "BG3401@2": { + "A": "0", + "B": "BG3401", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217150.0, + 292667.6 + ], + "IO": "BG3401", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.10", + "SPS": "2" + }, + "BG3402@3": { + "A": "0", + "B": "BG3402", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217950.0, + 442667.6 + ], + "IO": "BG3402", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.11", + "SPS": "3" + }, + "BG3402@2": { + "A": "0", + "B": "BG3402", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217950.0, + 292667.6 + ], + "IO": "BG3402", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.11", + "SPS": "2" + }, + "BG3403@3": { + "A": "0", + "B": "BG3403", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218750.0, + 442667.6 + ], + "IO": "BG3403", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.12", + "SPS": "3" + }, + "BG3403@2": { + "A": "0", + "B": "BG3403", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218750.0, + 292667.6 + ], + "IO": "BG3403", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.12", + "SPS": "2" + }, + "BG3404@3": { + "A": "0", + "B": "BG3404", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219550.0, + 442667.6 + ], + "IO": "BG3404", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.13", + "SPS": "3" + }, + "BG3404@2": { + "A": "0", + "B": "BG3404", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219550.0, + 292667.6 + ], + "IO": "BG3404", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.13", + "SPS": "2" + }, + "BG3405@3": { + "A": "0", + "B": "BG3405", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220350.0, + 442667.6 + ], + "IO": "BG3405", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.14", + "SPS": "3" + }, + "BG3405@2": { + "A": "0", + "B": "BG3405", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220350.0, + 292667.6 + ], + "IO": "BG3405", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.14", + "SPS": "2" + }, + "BG3406@3": { + "A": "0", + "B": "BG3406", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221150.0, + 442667.6 + ], + "IO": "BG3406", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.15", + "SPS": "3" + }, + "BG3406@2": { + "A": "0", + "B": "BG3406", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221150.0, + 292667.6 + ], + "IO": "BG3406", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.15", + "SPS": "2" + }, + "BG3407@3": { + "A": "0", + "B": "BG3407", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221950.0, + 442667.6 + ], + "IO": "BG3407", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.16", + "SPS": "3" + }, + "BG3407@2": { + "A": "0", + "B": "BG3407", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221950.0, + 292667.6 + ], + "IO": "BG3407", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.16", + "SPS": "2" + }, + "BG3410@3": { + "A": "0", + "B": "BG3410", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223150.0, + 442667.6 + ], + "IO": "BG3410", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.17", + "SPS": "3" + }, + "BG3410@2": { + "A": "0", + "B": "BG3410", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223150.0, + 292667.6 + ], + "IO": "BG3410", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.17", + "SPS": "2" + }, + "BG3411@3": { + "A": "0", + "B": "BG3411", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223950.0, + 442667.6 + ], + "IO": "BG3411", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 18 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.18", + "SPS": "3" + }, + "BG3411@2": { + "A": "0", + "B": "BG3411", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223950.0, + 292667.6 + ], + "IO": "BG3411", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 18 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.18", + "SPS": "2" + }, + "BG3412@3": { + "A": "0", + "B": "BG3412", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224750.0, + 442667.6 + ], + "IO": "BG3412", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 19 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.19", + "SPS": "3" + }, + "BG3412@2": { + "A": "0", + "B": "BG3412", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224750.0, + 292667.6 + ], + "IO": "BG3412", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 19 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.19", + "SPS": "2" + }, + "BG3413@3": { + "A": "0", + "B": "BG3413", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225550.0, + 442667.6 + ], + "IO": "BG3413", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 20 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.20", + "SPS": "3" + }, + "BG3413@2": { + "A": "0", + "B": "BG3413", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225550.0, + 292667.6 + ], + "IO": "BG3413", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 20 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.20", + "SPS": "2" + }, + "BG3414@3": { + "A": "0", + "B": "BG3414", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226350.0, + 442667.6 + ], + "IO": "BG3414", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 21 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.21", + "SPS": "3" + }, + "BG3414@2": { + "A": "0", + "B": "BG3414", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226350.0, + 292667.6 + ], + "IO": "BG3414", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 21 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.21", + "SPS": "2" + }, + "BG3173@3": { + "A": "0", + "B": "BG3173", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225550.0, + 457807.7 + ], + "IO": "BG3173", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.20 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.20", + "SPS": "3" + }, + "BG3173@2": { + "A": "0", + "B": "BG3173", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225550.0, + 307807.7 + ], + "IO": "BG3173", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.20 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.20", + "SPS": "2" + }, + "BG3183@3": { + "A": "0", + "B": "BG3183", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227156.9, + 458839.5 + ], + "IO": "BG3183", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2102 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3183@2": { + "A": "0", + "B": "BG3183", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227156.9, + 308839.5 + ], + "IO": "BG3183", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor Str.2 (M1102)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3423@3": { + "A": "0", + "B": "BG3423", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227504.6, + 443172.0 + ], + "IO": "BG3423", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2108) ", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3423@2": { + "A": "0", + "B": "BG3423", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227504.6, + 293165.1 + ], + "IO": "BG3423", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1108)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3423@5": { + "A": "0", + "B": "BG3423", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234167.0, + 155331.3 + ], + "IO": "BG3423", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3423@4": { + "A": "0", + "B": "BG3423", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359485.4, + 750831.0 + ], + "IO": "BG3423", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 6 (AMR ILS-CV M4010) ", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3424@3": { + "A": "0", + "B": "BG3424", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 442604.1 + ], + "IO": "BG3424", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2108) ", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3424@2": { + "A": "0", + "B": "BG3424", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 292615.3 + ], + "IO": "BG3424", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1108)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3424@5": { + "A": "0", + "B": "BG3424", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234162.4, + 155648.4 + ], + "IO": "BG3424", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3424@4": { + "A": "0", + "B": "BG3424", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359648.7, + 750288.6 + ], + "IO": "BG3424", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (AMR ILS-CV M4010)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3421@3": { + "A": "0", + "B": "BG3421", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 442318.2 + ], + "IO": "BG3421", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2108) ", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3421@2": { + "A": "0", + "B": "BG3421", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 292318.2 + ], + "IO": "BG3421", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1108)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3421@5": { + "A": "0", + "B": "BG3421", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235410.7, + 151995.4 + ], + "IO": "BG3421", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3421@4": { + "A": "0", + "B": "BG3421", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358847.2, + 752169.1 + ], + "IO": "BG3421", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4002)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3422@3": { + "A": "0", + "B": "BG3422", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228273.8, + 442042.8 + ], + "IO": "BG3422", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2104 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3422@2": { + "A": "0", + "B": "BG3422", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228273.8, + 292042.8 + ], + "IO": "BG3422", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1104 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3422@5": { + "A": "0", + "B": "BG3422", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234162.4, + 154774.1 + ], + "IO": "BG3422", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3420@3": { + "A": "0", + "B": "BG3420", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228310.7, + 441208.2 + ], + "IO": "BG3420", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3420@2": { + "A": "0", + "B": "BG3420", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228310.7, + 291208.2 + ], + "IO": "BG3420", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3420@5": { + "A": "0", + "B": "BG3420", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233694.0, + 152131.9 + ], + "IO": "BG3420", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator(ILS-KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3420@4": { + "A": "0", + "B": "BG3420", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359629.3, + 752179.8 + ], + "IO": "BG3420", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (AMR ILS-CV M4002)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3425@3": { + "A": "0", + "B": "BG3425", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237420.4, + 441131.7 + ], + "IO": "BG3425", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (ILS-CV M2104 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3425@2": { + "A": "0", + "B": "BG3425", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227170.7, + 290142.1 + ], + "IO": "BG3425", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (ILS-CV M1104)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3425@5": { + "A": "0", + "B": "BG3425", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234178.8, + 156315.9 + ], + "IO": "BG3425", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3425@4": { + "A": "0", + "B": "BG3425", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358595.9, + 750842.9 + ], + "IO": "BG3425", + "ID": "", + "VERW": "Conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4010)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3426@3": { + "A": "0", + "B": "BG3426", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238544.6, + 441131.7 + ], + "IO": "BG3426", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (M2104)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3426@2": { + "A": "0", + "B": "BG3426", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239527.4, + 292032.2 + ], + "IO": "BG3426", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 3 (KR-M1104)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3426@5": { + "A": "0", + "B": "BG3426", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234167.0, + 156585.4 + ], + "IO": "BG3426", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3426@4": { + "A": "0", + "B": "BG3426", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358419.5, + 751919.1 + ], + "IO": "BG3426", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4002)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3450@3": { + "A": "0", + "B": "BG3450", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 442667.6 + ], + "IO": "BG3450", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.01", + "SPS": "3" + }, + "BG3450@2": { + "A": "0", + "B": "BG3450", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 292667.6 + ], + "IO": "BG3450", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.01", + "SPS": "2" + }, + "BG3450@4": { + "A": "0", + "B": "BG3450", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356382.4, + 752059.6 + ], + "IO": "BG3450", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor Ausfahrt MPS 01 (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3451@3": { + "A": "0", + "B": "BG3451", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 442667.6 + ], + "IO": "BG3451", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.02", + "SPS": "3" + }, + "BG3451@2": { + "A": "0", + "B": "BG3451", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 292667.6 + ], + "IO": "BG3451", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.02", + "SPS": "2" + }, + "BG3451@4": { + "A": "0", + "B": "BG3451", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355970.4, + 751432.4 + ], + "IO": "BG3451", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator Ausfahrt MPS 1 (AMR ILS-CV M4009)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3452@3": { + "A": "0", + "B": "BG3452", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 442667.6 + ], + "IO": "BG3452", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.03", + "SPS": "3" + }, + "BG3452@2": { + "A": "0", + "B": "BG3452", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 292667.6 + ], + "IO": "BG3452", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.03", + "SPS": "2" + }, + "BG3453@3": { + "A": "0", + "B": "BG3453", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 442667.6 + ], + "IO": "BG3453", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.04", + "SPS": "3" + }, + "BG3453@2": { + "A": "0", + "B": "BG3453", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 292667.6 + ], + "IO": "BG3453", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.04", + "SPS": "2" + }, + "BG3454@3": { + "A": "0", + "B": "BG3454", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 442667.6 + ], + "IO": "BG3454", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.05", + "SPS": "3" + }, + "BG3454@2": { + "A": "0", + "B": "BG3454", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 292667.6 + ], + "IO": "BG3454", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.05", + "SPS": "2" + }, + "BG3454@4": { + "A": "0", + "B": "BG3454", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 349648.4, + 749789.4 + ], + "IO": "BG3454", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Position MPS 1 (AMR ILS-CV M4009)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3455@3": { + "A": "0", + "B": "BG3455", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 442667.6 + ], + "IO": "BG3455", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.06", + "SPS": "3" + }, + "BG3455@2": { + "A": "0", + "B": "BG3455", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 292667.6 + ], + "IO": "BG3455", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.06", + "SPS": "2" + }, + "BG3455@4": { + "A": "0", + "B": "BG3455", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 349115.1, + 751150.8 + ], + "IO": "BG3455", + "ID": "", + "VERW": "MT unloaded", + "BEZEICHNUNG": "MT ist entladen MPS 1 (AMR ILS-CV M4009)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3456@3": { + "A": "0", + "B": "BG3456", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 442667.6 + ], + "IO": "BG3456", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.07", + "SPS": "3" + }, + "BG3456@2": { + "A": "0", + "B": "BG3456", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 292667.6 + ], + "IO": "BG3456", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.07", + "SPS": "2" + }, + "BG3457@3": { + "A": "0", + "B": "BG3457", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 442667.6 + ], + "IO": "BG3457", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.08", + "SPS": "3" + }, + "BG3457@2": { + "A": "0", + "B": "BG3457", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 292667.6 + ], + "IO": "BG3457", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.08", + "SPS": "2" + }, + "BG3460@3": { + "A": "0", + "B": "BG3460", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 442667.6 + ], + "IO": "BG3460", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.09", + "SPS": "3" + }, + "BG3460@2": { + "A": "0", + "B": "BG3460", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 292667.6 + ], + "IO": "BG3460", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.09", + "SPS": "2" + }, + "BG3461@3": { + "A": "0", + "B": "BG3461", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 442667.6 + ], + "IO": "BG3461", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.10", + "SPS": "3" + }, + "BG3461@2": { + "A": "0", + "B": "BG3461", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 292667.6 + ], + "IO": "BG3461", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.10", + "SPS": "2" + }, + "BG3462@3": { + "A": "0", + "B": "BG3462", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 442667.6 + ], + "IO": "BG3462", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.11", + "SPS": "3" + }, + "BG3462@2": { + "A": "0", + "B": "BG3462", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 292667.6 + ], + "IO": "BG3462", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.11", + "SPS": "2" + }, + "BG3463@3": { + "A": "0", + "B": "BG3463", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 442667.6 + ], + "IO": "BG3463", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.12", + "SPS": "3" + }, + "BG3463@2": { + "A": "0", + "B": "BG3463", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 292667.6 + ], + "IO": "BG3463", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.12", + "SPS": "2" + }, + "BG3464@3": { + "A": "0", + "B": "BG3464", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239150.0, + 442667.6 + ], + "IO": "BG3464", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.4.13", + "SPS": "3" + }, + "BG3464@2": { + "A": "0", + "B": "BG3464", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239150.0, + 292667.6 + ], + "IO": "BG3464", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.4.13", + "SPS": "2" + }, + "BG3241@3": { + "A": "0", + "B": "BG3241", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187189.0, + 442337.7 + ], + "IO": "BG3241", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2105) ", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3241@2": { + "A": "0", + "B": "BG3241", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187300.2, + 292318.2 + ], + "IO": "BG3241", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1105)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3241@5": { + "A": "0", + "B": "BG3241", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216292.0, + 151900.4 + ], + "IO": "BG3241", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 5m", + "SPS": "5" + }, + "BG3241@4": { + "A": "0", + "B": "BG3241", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 378156.7, + 750287.5 + ], + "IO": "BG3241", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Position MPS 3 (AMR ILS-CV M04001)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3241@1": { + "A": "0", + "B": "BG3241", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 341970.0, + 164121.6 + ], + "IO": "BG3241", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M0100)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3480@3": { + "A": "0", + "B": "BG3480", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187132.0, + 436871.7 + ], + "IO": "BG3480", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3480@2": { + "A": "0", + "B": "BG3480", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187132.0, + 286871.7 + ], + "IO": "BG3480", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1205)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3484@3": { + "A": "0", + "B": "BG3484", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187127.8, + 436279.5 + ], + "IO": "BG3484", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3484@2": { + "A": "0", + "B": "BG3484", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187127.8, + 286279.5 + ], + "IO": "BG3484", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1205)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3483@3": { + "A": "0", + "B": "BG3483", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187781.9, + 437835.0 + ], + "IO": "BG3483", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2201) Block 2.2.1", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3483@2": { + "A": "0", + "B": "BG3483", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187781.9, + 287835.0 + ], + "IO": "BG3483", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M1201)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3485@3": { + "A": "0", + "B": "BG3485", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187126.0, + 435968.4 + ], + "IO": "BG3485", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K2205 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3485@2": { + "A": "0", + "B": "BG3485", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187126.0, + 285968.4 + ], + "IO": "BG3485", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (ILS-CV M1205)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3487@3": { + "A": "0", + "B": "BG3487", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "2", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183192.3, + 438127.8 + ], + "IO": "BG3487", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K2201 Einfahrt Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3487@2": { + "A": "0", + "B": "BG3487", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183192.3, + 288127.8 + ], + "IO": "BG3487", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1201 Einfahrt Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3490@3": { + "A": "0", + "B": "BG3490", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178779.0, + 438122.4 + ], + "IO": "BG3490", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2201 Einfahrt Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3490@2": { + "A": "0", + "B": "BG3490", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178779.0, + 288122.4 + ], + "IO": "BG3490", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1201 Einfahrt Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3491@3": { + "A": "0", + "B": "BG3491", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175605.8, + 438122.4 + ], + "IO": "BG3491", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K2201 Einfahrt Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3491@2": { + "A": "0", + "B": "BG3491", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175605.8, + 288122.4 + ], + "IO": "BG3491", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1201 Einfahrt Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3481@3": { + "A": "0", + "B": "BG3481", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186977.5, + 437835.0 + ], + "IO": "BG3481", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2201 ) Block 2.2.1", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3481@2": { + "A": "0", + "B": "BG3481", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186977.5, + 287835.0 + ], + "IO": "BG3481", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1201 ) Block 1.2.1", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3482@3": { + "A": "0", + "B": "BG3482", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186578.7, + 438134.2 + ], + "IO": "BG3482", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K2201 Einfahrt Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3482@2": { + "A": "0", + "B": "BG3482", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186578.7, + 288134.2 + ], + "IO": "BG3482", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1201 Einfahrt Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3524@3": { + "A": "0", + "B": "BG3524", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175150.0, + 436822.0 + ], + "IO": "BG3524", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.13", + "SPS": "3" + }, + "BG3524@2": { + "A": "0", + "B": "BG3524", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175150.0, + 286822.0 + ], + "IO": "BG3524", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.13", + "SPS": "2" + }, + "BG3523@3": { + "A": "0", + "B": "BG3523", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 436822.3 + ], + "IO": "BG3523", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.12", + "SPS": "3" + }, + "BG3523@2": { + "A": "0", + "B": "BG3523", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 286822.3 + ], + "IO": "BG3523", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.12", + "SPS": "2" + }, + "BG3516@3": { + "A": "0", + "B": "BG3516", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 436822.0 + ], + "IO": "BG3516", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.07", + "SPS": "3" + }, + "BG3516@2": { + "A": "0", + "B": "BG3516", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 286822.0 + ], + "IO": "BG3516", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.07", + "SPS": "2" + }, + "BG3515@3": { + "A": "0", + "B": "BG3515", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.9, + 436822.3 + ], + "IO": "BG3515", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.06", + "SPS": "3" + }, + "BG3515@2": { + "A": "0", + "B": "BG3515", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.9, + 286822.3 + ], + "IO": "BG3515", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.06", + "SPS": "2" + }, + "BG3514@3": { + "A": "0", + "B": "BG3514", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.9, + 436822.3 + ], + "IO": "BG3514", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.05", + "SPS": "3" + }, + "BG3514@2": { + "A": "0", + "B": "BG3514", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.9, + 286822.3 + ], + "IO": "BG3514", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.05", + "SPS": "2" + }, + "BG3513@3": { + "A": "0", + "B": "BG3513", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 436822.0 + ], + "IO": "BG3513", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.04", + "SPS": "3" + }, + "BG3513@2": { + "A": "0", + "B": "BG3513", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 286822.0 + ], + "IO": "BG3513", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.04", + "SPS": "2" + }, + "BG3512@3": { + "A": "0", + "B": "BG3512", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184349.9, + 436822.3 + ], + "IO": "BG3512", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.03", + "SPS": "3" + }, + "BG3512@2": { + "A": "0", + "B": "BG3512", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184349.9, + 286822.3 + ], + "IO": "BG3512", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.03", + "SPS": "2" + }, + "BG3511@3": { + "A": "0", + "B": "BG3511", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 436822.3 + ], + "IO": "BG3511", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.02", + "SPS": "3" + }, + "BG3511@2": { + "A": "0", + "B": "BG3511", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 286822.3 + ], + "IO": "BG3511", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.02", + "SPS": "2" + }, + "BG3510@3": { + "A": "0", + "B": "BG3510", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 436695.7 + ], + "IO": "BG3510", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.01", + "SPS": "3" + }, + "BG3510@2": { + "A": "0", + "B": "BG3510", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 286695.7 + ], + "IO": "BG3510", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.01", + "SPS": "2" + }, + "BG3522@3": { + "A": "0", + "B": "BG3522", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 436822.2 + ], + "IO": "BG3522", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.11", + "SPS": "3" + }, + "BG3522@2": { + "A": "0", + "B": "BG3522", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 286822.2 + ], + "IO": "BG3522", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.11", + "SPS": "2" + }, + "BG3521@3": { + "A": "0", + "B": "BG3521", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177550.0, + 436821.9 + ], + "IO": "BG3521", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.10", + "SPS": "3" + }, + "BG3521@2": { + "A": "0", + "B": "BG3521", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177550.0, + 286821.9 + ], + "IO": "BG3521", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.10", + "SPS": "2" + }, + "BG3520@3": { + "A": "0", + "B": "BG3520", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 436822.2 + ], + "IO": "BG3520", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.09", + "SPS": "3" + }, + "BG3520@2": { + "A": "0", + "B": "BG3520", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 286822.2 + ], + "IO": "BG3520", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.09", + "SPS": "2" + }, + "BG3517@3": { + "A": "0", + "B": "BG3517", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 436822.2 + ], + "IO": "BG3517", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.08", + "SPS": "3" + }, + "BG3517@2": { + "A": "0", + "B": "BG3517", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 286822.2 + ], + "IO": "BG3517", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.08", + "SPS": "2" + }, + "BG3540@3": { + "A": "0", + "B": "BG3540", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204368.7, + 436871.7 + ], + "IO": "BG3540", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3540@2": { + "A": "0", + "B": "BG3540", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204368.7, + 286871.7 + ], + "IO": "BG3540", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1206)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3544@3": { + "A": "0", + "B": "BG3544", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204364.4, + 436279.5 + ], + "IO": "BG3544", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3544@2": { + "A": "0", + "B": "BG3544", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204364.4, + 286279.5 + ], + "IO": "BG3544", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1206)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3545@3": { + "A": "0", + "B": "BG3545", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204362.7, + 435968.4 + ], + "IO": "BG3545", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K2206 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3545@2": { + "A": "0", + "B": "BG3545", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204362.7, + 285968.4 + ], + "IO": "BG3545", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (ILS-CV M1206)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3543@3": { + "A": "0", + "B": "BG3543", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204250.1, + 438134.2 + ], + "IO": "BG3543", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor Str.2 (KR-M2201)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3543@2": { + "A": "0", + "B": "BG3543", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204203.3, + 288467.7 + ], + "IO": "BG3543", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor Str.2 (KR-M1201)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3550@3": { + "A": "0", + "B": "BG3550", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196643.8, + 438121.0 + ], + "IO": "BG3550", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2201 Einfahrt Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3550@2": { + "A": "0", + "B": "BG3550", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196643.8, + 288121.0 + ], + "IO": "BG3550", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1201 Einfahrt Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3541@3": { + "A": "0", + "B": "BG3541", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204081.7, + 437835.0 + ], + "IO": "BG3541", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2201 ) Block 2.2.2", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3541@2": { + "A": "0", + "B": "BG3541", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204081.7, + 287835.0 + ], + "IO": "BG3541", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1201 ) Block 1.2.2", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3542@3": { + "A": "0", + "B": "BG3542", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203322.0, + 438134.2 + ], + "IO": "BG3542", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K2201 Einfahrt Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3542@2": { + "A": "0", + "B": "BG3542", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203729.6, + 288134.2 + ], + "IO": "BG3542", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1201 Einfahrt Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3551@3": { + "A": "0", + "B": "BG3551", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193540.2, + 438122.4 + ], + "IO": "BG3551", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K2201 Einfahrt Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3551@2": { + "A": "0", + "B": "BG3551", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193540.2, + 288122.4 + ], + "IO": "BG3551", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1201 Einfahrt Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3590@3": { + "A": "0", + "B": "BG3590", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 436822.3 + ], + "IO": "BG3590", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.17", + "SPS": "3" + }, + "BG3590@2": { + "A": "0", + "B": "BG3590", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 286822.3 + ], + "IO": "BG3590", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.17", + "SPS": "2" + }, + "BG3587@3": { + "A": "0", + "B": "BG3587", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.1, + 436822.0 + ], + "IO": "BG3587", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.16", + "SPS": "3" + }, + "BG3587@2": { + "A": "0", + "B": "BG3587", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.1, + 286822.0 + ], + "IO": "BG3587", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.16", + "SPS": "2" + }, + "BG3586@3": { + "A": "0", + "B": "BG3586", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 436822.3 + ], + "IO": "BG3586", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.15", + "SPS": "3" + }, + "BG3586@2": { + "A": "0", + "B": "BG3586", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 286822.3 + ], + "IO": "BG3586", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.15", + "SPS": "2" + }, + "BG3585@3": { + "A": "0", + "B": "BG3585", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 436822.3 + ], + "IO": "BG3585", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.14", + "SPS": "3" + }, + "BG3585@2": { + "A": "0", + "B": "BG3585", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 286822.3 + ], + "IO": "BG3585", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.14", + "SPS": "2" + }, + "BG3552@3": { + "A": "0", + "B": "BG3552", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189411.3, + 438122.4 + ], + "IO": "BG3552", + "ID": "", + "VERW": "Sync P5", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K2201 Einfahrt Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3552@2": { + "A": "0", + "B": "BG3552", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189411.3, + 288122.4 + ], + "IO": "BG3552", + "ID": "", + "VERW": "Sync P5", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K1201 Einfahrt Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3575@3": { + "A": "0", + "B": "BG3575", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 436822.4 + ], + "IO": "BG3575", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.06", + "SPS": "3" + }, + "BG3575@2": { + "A": "0", + "B": "BG3575", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 286822.4 + ], + "IO": "BG3575", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.06", + "SPS": "2" + }, + "BG3574@3": { + "A": "0", + "B": "BG3574", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 436822.4 + ], + "IO": "BG3574", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.05", + "SPS": "3" + }, + "BG3574@2": { + "A": "0", + "B": "BG3574", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 286822.4 + ], + "IO": "BG3574", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.05", + "SPS": "2" + }, + "BG3573@3": { + "A": "0", + "B": "BG3573", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.1, + 436822.1 + ], + "IO": "BG3573", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.04", + "SPS": "3" + }, + "BG3573@2": { + "A": "0", + "B": "BG3573", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.1, + 286822.1 + ], + "IO": "BG3573", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.04", + "SPS": "2" + }, + "BG3572@3": { + "A": "0", + "B": "BG3572", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 436822.4 + ], + "IO": "BG3572", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.03", + "SPS": "3" + }, + "BG3572@2": { + "A": "0", + "B": "BG3572", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 286822.4 + ], + "IO": "BG3572", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.03", + "SPS": "2" + }, + "BG3571@3": { + "A": "0", + "B": "BG3571", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 436822.4 + ], + "IO": "BG3571", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.02", + "SPS": "3" + }, + "BG3571@2": { + "A": "0", + "B": "BG3571", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 286822.4 + ], + "IO": "BG3571", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.02", + "SPS": "2" + }, + "BG3570@3": { + "A": "0", + "B": "BG3570", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 436695.7 + ], + "IO": "BG3570", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.01", + "SPS": "3" + }, + "BG3570@2": { + "A": "0", + "B": "BG3570", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 286695.7 + ], + "IO": "BG3570", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.01", + "SPS": "2" + }, + "BG3576@3": { + "A": "0", + "B": "BG3576", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 436822.4 + ], + "IO": "BG3576", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.07", + "SPS": "3" + }, + "BG3576@2": { + "A": "0", + "B": "BG3576", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 286822.4 + ], + "IO": "BG3576", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.07", + "SPS": "2" + }, + "BG3577@3": { + "A": "0", + "B": "BG3577", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.2, + 436822.4 + ], + "IO": "BG3577", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.08", + "SPS": "3" + }, + "BG3577@2": { + "A": "0", + "B": "BG3577", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.2, + 286822.4 + ], + "IO": "BG3577", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.08", + "SPS": "2" + }, + "BG3584@3": { + "A": "0", + "B": "BG3584", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193100.2, + 436822.0 + ], + "IO": "BG3584", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.13", + "SPS": "3" + }, + "BG3584@2": { + "A": "0", + "B": "BG3584", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193100.2, + 286822.0 + ], + "IO": "BG3584", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.13", + "SPS": "2" + }, + "BG3583@3": { + "A": "0", + "B": "BG3583", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193900.1, + 436822.3 + ], + "IO": "BG3583", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.12", + "SPS": "3" + }, + "BG3583@2": { + "A": "0", + "B": "BG3583", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193900.1, + 286822.3 + ], + "IO": "BG3583", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.12", + "SPS": "2" + }, + "BG3582@3": { + "A": "0", + "B": "BG3582", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194700.1, + 436822.3 + ], + "IO": "BG3582", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.11", + "SPS": "3" + }, + "BG3582@2": { + "A": "0", + "B": "BG3582", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194700.1, + 286822.3 + ], + "IO": "BG3582", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.11", + "SPS": "2" + }, + "BG3581@3": { + "A": "0", + "B": "BG3581", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195500.2, + 436822.0 + ], + "IO": "BG3581", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.10", + "SPS": "3" + }, + "BG3581@2": { + "A": "0", + "B": "BG3581", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195500.2, + 286822.0 + ], + "IO": "BG3581", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.10", + "SPS": "2" + }, + "BG3580@3": { + "A": "0", + "B": "BG3580", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196300.1, + 436822.3 + ], + "IO": "BG3580", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.09", + "SPS": "3" + }, + "BG3580@2": { + "A": "0", + "B": "BG3580", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196300.1, + 286822.3 + ], + "IO": "BG3580", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.09", + "SPS": "2" + }, + "BG3547@3": { + "A": "0", + "B": "BG3547", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200286.8, + 438122.4 + ], + "IO": "BG3547", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K2201 Einfahrt Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3547@2": { + "A": "0", + "B": "BG3547", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200286.8, + 288122.4 + ], + "IO": "BG3547", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1201 Einfahrt Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3186@3": { + "A": "0", + "B": "BG3186", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227611.1, + 456340.9 + ], + "IO": "BG3186", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2102)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": " ", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3186@2": { + "A": "0", + "B": "BG3186", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227611.3, + 306312.8 + ], + "IO": "BG3186", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 1102)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3486@3": { + "A": "0", + "B": "BG3486", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187126.0, + 435348.5 + ], + "IO": "BG3486", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M2205)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": " ", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3486@2": { + "A": "0", + "B": "BG3486", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187126.0, + 285390.4 + ], + "IO": "BG3486", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1205)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3546@3": { + "A": "0", + "B": "BG3546", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204350.9, + 435329.8 + ], + "IO": "BG3546", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M2206)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": " ", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3546@2": { + "A": "0", + "B": "BG3546", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204356.5, + 285329.5 + ], + "IO": "BG3546", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1206)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3617@3": { + "A": "0", + "B": "BG3617", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208458.9, + 438449.1 + ], + "IO": "BG3617", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3617@2": { + "A": "0", + "B": "BG3617", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207474.9, + 288750.0 + ], + "IO": "BG3617", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3613@3": { + "A": "0", + "B": "BG3613", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225266.2, + 438116.2 + ], + "IO": "BG3613", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.6 (KR-K2202 Einfahrt Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3613@2": { + "A": "0", + "B": "BG3613", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225266.2, + 288116.2 + ], + "IO": "BG3613", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.6 (KR-K1202 Einfahrt Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3612@3": { + "A": "0", + "B": "BG3612", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221679.0, + 438116.2 + ], + "IO": "BG3612", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K2202 Einfahrt Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3612@2": { + "A": "0", + "B": "BG3612", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221679.0, + 288116.2 + ], + "IO": "BG3612", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K1202 Einfahrt Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3611@3": { + "A": "0", + "B": "BG3611", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218467.2, + 438124.4 + ], + "IO": "BG3611", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K2202 Einfahrt Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3611@2": { + "A": "0", + "B": "BG3611", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218467.2, + 288478.4 + ], + "IO": "BG3611", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1202 Einfahrt Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3610@3": { + "A": "0", + "B": "BG3610", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214297.9, + 438116.2 + ], + "IO": "BG3610", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2202 Einfahrt Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3610@2": { + "A": "0", + "B": "BG3610", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214297.9, + 288116.2 + ], + "IO": "BG3610", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1202 Einfahrt Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3607@3": { + "A": "0", + "B": "BG3607", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211110.3, + 438116.2 + ], + "IO": "BG3607", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K2202 Einfahrt Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3607@2": { + "A": "0", + "B": "BG3607", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211110.3, + 288116.2 + ], + "IO": "BG3607", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1202 Einfahrt Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3600@3": { + "A": "0", + "B": "BG3600", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207428.1, + 436728.5 + ], + "IO": "BG3600", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3600@2": { + "A": "0", + "B": "BG3600", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207428.1, + 286728.5 + ], + "IO": "BG3600", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3604@3": { + "A": "0", + "B": "BG3604", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206614.7, + 436163.2 + ], + "IO": "BG3604", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3604@2": { + "A": "0", + "B": "BG3604", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206614.7, + 286163.2 + ], + "IO": "BG3604", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1207)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3605@3": { + "A": "0", + "B": "BG3605", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206612.9, + 435852.1 + ], + "IO": "BG3605", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K2207 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3605@2": { + "A": "0", + "B": "BG3605", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206612.9, + 285852.1 + ], + "IO": "BG3605", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K1207 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3603@3": { + "A": "0", + "B": "BG3603", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206622.3, + 437121.2 + ], + "IO": "BG3603", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor Str.2 (KR-M2202)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3603@2": { + "A": "0", + "B": "BG3603", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206622.3, + 287121.2 + ], + "IO": "BG3603", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor Str.2 (KR-M1202)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3601@3": { + "A": "0", + "B": "BG3601", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207166.5, + 437833.0 + ], + "IO": "BG3601", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2202 ) Block 2.2.3", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3601@2": { + "A": "0", + "B": "BG3601", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207166.5, + 287833.0 + ], + "IO": "BG3601", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1202 ) Block 1.2.3", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3602@3": { + "A": "0", + "B": "BG3602", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207629.1, + 438128.1 + ], + "IO": "BG3602", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K2202 Einfahrt Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3602@2": { + "A": "0", + "B": "BG3602", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207629.1, + 288128.1 + ], + "IO": "BG3602", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1202 Einfahrt Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3630@3": { + "A": "0", + "B": "BG3630", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208400.3, + 436801.8 + ], + "IO": "BG3630", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.01", + "SPS": "3" + }, + "BG3630@2": { + "A": "0", + "B": "BG3630", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208400.3, + 286801.8 + ], + "IO": "BG3630", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.01", + "SPS": "2" + }, + "BG3631@3": { + "A": "0", + "B": "BG3631", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209200.3, + 436801.7 + ], + "IO": "BG3631", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.02", + "SPS": "3" + }, + "BG3631@2": { + "A": "0", + "B": "BG3631", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209200.3, + 286801.7 + ], + "IO": "BG3631", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.02", + "SPS": "2" + }, + "BG3632@3": { + "A": "0", + "B": "BG3632", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210000.3, + 436801.7 + ], + "IO": "BG3632", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.03", + "SPS": "3" + }, + "BG3632@2": { + "A": "0", + "B": "BG3632", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210000.3, + 286801.7 + ], + "IO": "BG3632", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.03", + "SPS": "2" + }, + "BG3633@3": { + "A": "0", + "B": "BG3633", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211146.4, + 436801.7 + ], + "IO": "BG3633", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.04", + "SPS": "3" + }, + "BG3633@2": { + "A": "0", + "B": "BG3633", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211146.4, + 286801.7 + ], + "IO": "BG3633", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.04", + "SPS": "2" + }, + "BG3634@3": { + "A": "0", + "B": "BG3634", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211946.4, + 436801.7 + ], + "IO": "BG3634", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.05", + "SPS": "3" + }, + "BG3634@2": { + "A": "0", + "B": "BG3634", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211946.4, + 286801.7 + ], + "IO": "BG3634", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.05", + "SPS": "2" + }, + "BG3635@3": { + "A": "0", + "B": "BG3635", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212746.4, + 436801.7 + ], + "IO": "BG3635", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.06", + "SPS": "3" + }, + "BG3635@2": { + "A": "0", + "B": "BG3635", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212746.4, + 286801.7 + ], + "IO": "BG3635", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.06", + "SPS": "2" + }, + "BG3636@2": { + "A": "0", + "B": "BG3636", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213545.6, + 286801.7 + ], + "IO": "BG3636", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.07", + "SPS": "2" + }, + "BG3637@3": { + "A": "0", + "B": "BG3637", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214346.4, + 436801.7 + ], + "IO": "BG3637", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.08", + "SPS": "3" + }, + "BG3637@2": { + "A": "0", + "B": "BG3637", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214346.4, + 286801.7 + ], + "IO": "BG3637", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.08", + "SPS": "2" + }, + "BG3640@3": { + "A": "0", + "B": "BG3640", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215146.4, + 436802.5 + ], + "IO": "BG3640", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.09", + "SPS": "3" + }, + "BG3640@2": { + "A": "0", + "B": "BG3640", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215146.4, + 286802.5 + ], + "IO": "BG3640", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.09", + "SPS": "2" + }, + "BG3641@3": { + "A": "0", + "B": "BG3641", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217150.3, + 436801.5 + ], + "IO": "BG3641", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.10", + "SPS": "3" + }, + "BG3641@2": { + "A": "0", + "B": "BG3641", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217150.3, + 286801.5 + ], + "IO": "BG3641", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.10", + "SPS": "2" + }, + "BG3642@3": { + "A": "0", + "B": "BG3642", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217950.3, + 436801.5 + ], + "IO": "BG3642", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.11", + "SPS": "3" + }, + "BG3642@2": { + "A": "0", + "B": "BG3642", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217950.3, + 286801.5 + ], + "IO": "BG3642", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.11", + "SPS": "2" + }, + "BG3643@3": { + "A": "0", + "B": "BG3643", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218750.3, + 436801.4 + ], + "IO": "BG3643", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.12", + "SPS": "3" + }, + "BG3643@2": { + "A": "0", + "B": "BG3643", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218750.3, + 286801.4 + ], + "IO": "BG3643", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.12", + "SPS": "2" + }, + "BG3644@3": { + "A": "0", + "B": "BG3644", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219549.4, + 436801.5 + ], + "IO": "BG3644", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.13", + "SPS": "3" + }, + "BG3644@2": { + "A": "0", + "B": "BG3644", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219549.4, + 286801.5 + ], + "IO": "BG3644", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.13", + "SPS": "2" + }, + "BG3645@3": { + "A": "0", + "B": "BG3645", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220350.3, + 436801.4 + ], + "IO": "BG3645", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.14", + "SPS": "3" + }, + "BG3645@2": { + "A": "0", + "B": "BG3645", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220350.3, + 286801.4 + ], + "IO": "BG3645", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.14", + "SPS": "2" + }, + "BG3646@3": { + "A": "0", + "B": "BG3646", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221150.3, + 436801.5 + ], + "IO": "BG3646", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.15", + "SPS": "3" + }, + "BG3646@2": { + "A": "0", + "B": "BG3646", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221150.3, + 286801.5 + ], + "IO": "BG3646", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.15", + "SPS": "2" + }, + "BG3647@3": { + "A": "0", + "B": "BG3647", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221950.3, + 436801.4 + ], + "IO": "BG3647", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.16", + "SPS": "3" + }, + "BG3647@2": { + "A": "0", + "B": "BG3647", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221950.3, + 286801.4 + ], + "IO": "BG3647", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.16", + "SPS": "2" + }, + "BG3650@3": { + "A": "0", + "B": "BG3650", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223150.3, + 436801.4 + ], + "IO": "BG3650", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.17", + "SPS": "3" + }, + "BG3650@2": { + "A": "0", + "B": "BG3650", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223150.3, + 286801.4 + ], + "IO": "BG3650", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.17", + "SPS": "2" + }, + "BG3651@3": { + "A": "0", + "B": "BG3651", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223950.3, + 436801.5 + ], + "IO": "BG3651", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.18 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.18", + "SPS": "3" + }, + "BG3651@2": { + "A": "0", + "B": "BG3651", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223950.3, + 286801.5 + ], + "IO": "BG3651", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.18 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.18", + "SPS": "2" + }, + "BG3652@3": { + "A": "0", + "B": "BG3652", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224748.7, + 436801.4 + ], + "IO": "BG3652", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.19 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.19", + "SPS": "3" + }, + "BG3652@2": { + "A": "0", + "B": "BG3652", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224748.7, + 286801.4 + ], + "IO": "BG3652", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.19 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.19", + "SPS": "2" + }, + "BG3654@3": { + "A": "0", + "B": "BG3654", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226350.3, + 436801.5 + ], + "IO": "BG3654", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.21 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.1.3.21", + "SPS": "3" + }, + "BG3654@2": { + "A": "0", + "B": "BG3654", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226350.3, + 286801.5 + ], + "IO": "BG3654", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.21 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.1.3.21", + "SPS": "2" + }, + "BG3653@3": { + "A": "0", + "B": "BG3653", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225550.3, + 436801.5 + ], + "IO": "BG3653", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.20 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.20", + "SPS": "3" + }, + "BG3653@2": { + "A": "0", + "B": "BG3653", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225550.3, + 286801.5 + ], + "IO": "BG3653", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.20 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.20", + "SPS": "2" + }, + "BG3606@3": { + "A": "0", + "B": "BG3606", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206613.2, + 435231.8 + ], + "IO": "BG3606", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2207)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3606@2": { + "A": "0", + "B": "BG3606", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206608.8, + 285228.8 + ], + "IO": "BG3606", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1207)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3667@3": { + "A": "0", + "B": "BG3667", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231576.8, + 438129.8 + ], + "IO": "BG3667", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-M2202 Einfahrt Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3667@2": { + "A": "0", + "B": "BG3667", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231576.8, + 288129.8 + ], + "IO": "BG3667", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1202 Einfahrt Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3671@3": { + "A": "0", + "B": "BG3671", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238060.2, + 438118.9 + ], + "IO": "BG3671", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-M2202 Einfahrt Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3671@2": { + "A": "0", + "B": "BG3671", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238060.2, + 288118.9 + ], + "IO": "BG3671", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1202 Einfahrt Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3670@3": { + "A": "0", + "B": "BG3670", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234243.8, + 437126.8 + ], + "IO": "BG3670", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2202 Einfahrt Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3670@2": { + "A": "0", + "B": "BG3670", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235283.9, + 287131.5 + ], + "IO": "BG3670", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1202 Einfahrt Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3660@3": { + "A": "0", + "B": "BG3660", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227619.6, + 436850.7 + ], + "IO": "BG3660", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3660@2": { + "A": "0", + "B": "BG3660", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227619.6, + 286850.7 + ], + "IO": "BG3660", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1208)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3664@3": { + "A": "0", + "B": "BG3664", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227614.7, + 436268.5 + ], + "IO": "BG3664", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3664@2": { + "A": "0", + "B": "BG3664", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227614.7, + 286268.5 + ], + "IO": "BG3664", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1208)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3665@3": { + "A": "0", + "B": "BG3665", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227613.0, + 435957.3 + ], + "IO": "BG3665", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K2208 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3665@2": { + "A": "0", + "B": "BG3665", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227613.0, + 285957.3 + ], + "IO": "BG3665", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-M1208)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3661@3": { + "A": "0", + "B": "BG3661", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227916.6, + 437830.4 + ], + "IO": "BG3661", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2202 ) Block 2.2.4", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3661@2": { + "A": "0", + "B": "BG3661", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227916.6, + 287830.4 + ], + "IO": "BG3661", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1202 ) Block 1.2.4", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3662@3": { + "A": "0", + "B": "BG3662", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228749.8, + 438126.8 + ], + "IO": "BG3662", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-M2202 Einfahrt Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3662@2": { + "A": "0", + "B": "BG3662", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228219.8, + 288126.8 + ], + "IO": "BG3662", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1202 Einfahrt Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3690@3": { + "A": "0", + "B": "BG3690", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.3, + 436800.9 + ], + "IO": "BG3690", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.01", + "SPS": "3" + }, + "BG3690@2": { + "A": "0", + "B": "BG3690", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.3, + 286800.9 + ], + "IO": "BG3690", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.01", + "SPS": "2" + }, + "BG3691@3": { + "A": "0", + "B": "BG3691", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.3, + 436800.8 + ], + "IO": "BG3691", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.02", + "SPS": "3" + }, + "BG3691@2": { + "A": "0", + "B": "BG3691", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.3, + 286800.8 + ], + "IO": "BG3691", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.02", + "SPS": "2" + }, + "BG3692@3": { + "A": "0", + "B": "BG3692", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.3, + 436800.8 + ], + "IO": "BG3692", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.03", + "SPS": "3" + }, + "BG3692@2": { + "A": "0", + "B": "BG3692", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.3, + 286800.8 + ], + "IO": "BG3692", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.03", + "SPS": "2" + }, + "BG3693@3": { + "A": "0", + "B": "BG3693", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.3, + 436800.7 + ], + "IO": "BG3693", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.04", + "SPS": "3" + }, + "BG3693@2": { + "A": "0", + "B": "BG3693", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.3, + 286800.7 + ], + "IO": "BG3693", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.04", + "SPS": "2" + }, + "BG3694@3": { + "A": "0", + "B": "BG3694", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.3, + 436800.7 + ], + "IO": "BG3694", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.05", + "SPS": "3" + }, + "BG3694@2": { + "A": "0", + "B": "BG3694", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.3, + 286800.7 + ], + "IO": "BG3694", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.05", + "SPS": "2" + }, + "BG3695@3": { + "A": "0", + "B": "BG3695", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.3, + 436800.8 + ], + "IO": "BG3695", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.06", + "SPS": "3" + }, + "BG3695@2": { + "A": "0", + "B": "BG3695", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.3, + 286800.8 + ], + "IO": "BG3695", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.06", + "SPS": "2" + }, + "BG3696@3": { + "A": "0", + "B": "BG3696", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233949.4, + 436800.7 + ], + "IO": "BG3696", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.07", + "SPS": "3" + }, + "BG3696@2": { + "A": "0", + "B": "BG3696", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233949.4, + 286800.7 + ], + "IO": "BG3696", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.07", + "SPS": "2" + }, + "BG3697@3": { + "A": "0", + "B": "BG3697", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.3, + 436801.5 + ], + "IO": "BG3697", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.08", + "SPS": "3" + }, + "BG3697@2": { + "A": "0", + "B": "BG3697", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.3, + 286801.5 + ], + "IO": "BG3697", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.08", + "SPS": "2" + }, + "BG3701@3": { + "A": "0", + "B": "BG3701", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.3, + 436800.6 + ], + "IO": "BG3701", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.10", + "SPS": "3" + }, + "BG3701@2": { + "A": "0", + "B": "BG3701", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.3, + 286800.6 + ], + "IO": "BG3701", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.10", + "SPS": "2" + }, + "BG3702@3": { + "A": "0", + "B": "BG3702", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.3, + 436800.6 + ], + "IO": "BG3702", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.11", + "SPS": "3" + }, + "BG3702@2": { + "A": "0", + "B": "BG3702", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.3, + 286800.6 + ], + "IO": "BG3702", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.11", + "SPS": "2" + }, + "BG3703@3": { + "A": "0", + "B": "BG3703", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.3, + 436800.5 + ], + "IO": "BG3703", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.12", + "SPS": "3" + }, + "BG3703@2": { + "A": "0", + "B": "BG3703", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.3, + 286800.5 + ], + "IO": "BG3703", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.12", + "SPS": "2" + }, + "BG3704@3": { + "A": "0", + "B": "BG3704", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239149.4, + 436800.5 + ], + "IO": "BG3704", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.13", + "SPS": "3" + }, + "BG3704@2": { + "A": "0", + "B": "BG3704", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239149.4, + 286800.5 + ], + "IO": "BG3704", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.13", + "SPS": "2" + }, + "BG3700@3": { + "A": "0", + "B": "BG3700", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.3, + 436801.5 + ], + "IO": "BG3700", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.09", + "SPS": "3" + }, + "BG3700@2": { + "A": "0", + "B": "BG3700", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.3, + 286801.5 + ], + "IO": "BG3700", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.09", + "SPS": "2" + }, + "BG3674@3": { + "A": "0", + "B": "BG3674", + "C": "20073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241388.5, + 438691.8 + ], + "IO": "BG3674", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2202)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3663@3": { + "A": "0", + "B": "BG3663", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227157.2, + 437832.4 + ], + "IO": "BG3663", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor Str.2 (KR-M2202)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3663@2": { + "A": "0", + "B": "BG3663", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227157.2, + 287832.4 + ], + "IO": "BG3663", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor Str.2 (M1202)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3666@3": { + "A": "0", + "B": "BG3666", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227612.7, + 435343.3 + ], + "IO": "BG3666", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2208)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3666@2": { + "A": "0", + "B": "BG3666", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227612.5, + 285348.3 + ], + "IO": "BG3666", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1208)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3723@3": { + "A": "0", + "B": "BG3723", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187302.9, + 423809.2 + ], + "IO": "BG3723", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (Block 2.2.1) ", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3723@2": { + "A": "0", + "B": "BG3723", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187302.9, + 273688.7 + ], + "IO": "BG3723", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1205) ", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3724@3": { + "A": "0", + "B": "BG3724", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187300.2, + 423179.4 + ], + "IO": "BG3724", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M2205 Block 2.2.1) ", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3724@2": { + "A": "0", + "B": "BG3724", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187300.2, + 273116.7 + ], + "IO": "BG3724", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1205) ", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3720@3": { + "A": "0", + "B": "BG3720", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186664.6, + 421559.5 + ], + "IO": "BG3720", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3720@2": { + "A": "0", + "B": "BG3720", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186664.6, + 271559.5 + ], + "IO": "BG3720", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3763@3": { + "A": "0", + "B": "BG3763", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 423167.6 + ], + "IO": "BG3763", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.12", + "SPS": "3" + }, + "BG3763@2": { + "A": "0", + "B": "BG3763", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 273167.6 + ], + "IO": "BG3763", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.12", + "SPS": "2" + }, + "BG3762@3": { + "A": "0", + "B": "BG3762", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 423167.6 + ], + "IO": "BG3762", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.11", + "SPS": "3" + }, + "BG3762@2": { + "A": "0", + "B": "BG3762", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 273167.6 + ], + "IO": "BG3762", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.11", + "SPS": "2" + }, + "BG3761@3": { + "A": "0", + "B": "BG3761", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 423167.6 + ], + "IO": "BG3761", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.10", + "SPS": "3" + }, + "BG3761@2": { + "A": "0", + "B": "BG3761", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 273167.6 + ], + "IO": "BG3761", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.10", + "SPS": "2" + }, + "BG3760@3": { + "A": "0", + "B": "BG3760", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 423167.6 + ], + "IO": "BG3760", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.09", + "SPS": "3" + }, + "BG3760@2": { + "A": "0", + "B": "BG3760", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 273167.6 + ], + "IO": "BG3760", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.09", + "SPS": "2" + }, + "BG3757@3": { + "A": "0", + "B": "BG3757", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 423167.6 + ], + "IO": "BG3757", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.08", + "SPS": "3" + }, + "BG3757@2": { + "A": "0", + "B": "BG3757", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 273167.6 + ], + "IO": "BG3757", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.08", + "SPS": "2" + }, + "BG3764@3": { + "A": "0", + "B": "BG3764", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 423167.6 + ], + "IO": "BG3764", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.13", + "SPS": "3" + }, + "BG3764@2": { + "A": "0", + "B": "BG3764", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 273167.6 + ], + "IO": "BG3764", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.13", + "SPS": "2" + }, + "BG3756@3": { + "A": "0", + "B": "BG3756", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 423167.6 + ], + "IO": "BG3756", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.07", + "SPS": "3" + }, + "BG3756@2": { + "A": "0", + "B": "BG3756", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 273167.6 + ], + "IO": "BG3756", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.07", + "SPS": "2" + }, + "BG3755@3": { + "A": "0", + "B": "BG3755", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 423167.6 + ], + "IO": "BG3755", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.06", + "SPS": "3" + }, + "BG3755@2": { + "A": "0", + "B": "BG3755", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 273167.6 + ], + "IO": "BG3755", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.06", + "SPS": "2" + }, + "BG3754@3": { + "A": "0", + "B": "BG3754", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 423167.6 + ], + "IO": "BG3754", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.05", + "SPS": "3" + }, + "BG3754@2": { + "A": "0", + "B": "BG3754", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 273167.6 + ], + "IO": "BG3754", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.05", + "SPS": "2" + }, + "BG3753@3": { + "A": "0", + "B": "BG3753", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 423167.6 + ], + "IO": "BG3753", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.04", + "SPS": "3" + }, + "BG3753@2": { + "A": "0", + "B": "BG3753", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 273167.6 + ], + "IO": "BG3753", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.04", + "SPS": "2" + }, + "BG3752@3": { + "A": "0", + "B": "BG3752", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 423167.6 + ], + "IO": "BG3752", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.03", + "SPS": "3" + }, + "BG3752@2": { + "A": "0", + "B": "BG3752", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 273167.6 + ], + "IO": "BG3752", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.03", + "SPS": "2" + }, + "BG3751@3": { + "A": "0", + "B": "BG3751", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 423167.6 + ], + "IO": "BG3751", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.02", + "SPS": "3" + }, + "BG3751@2": { + "A": "0", + "B": "BG3751", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 273167.6 + ], + "IO": "BG3751", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.02", + "SPS": "2" + }, + "BG3750@3": { + "A": "0", + "B": "BG3750", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 423167.6 + ], + "IO": "BG3750", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.1.01", + "SPS": "3" + }, + "BG3750@2": { + "A": "0", + "B": "BG3750", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 273167.6 + ], + "IO": "BG3750", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.01", + "SPS": "2" + }, + "BG3722@3": { + "A": "0", + "B": "BG3722", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186431.0, + 422542.8 + ], + "IO": "BG3722", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2203 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3722@2": { + "A": "0", + "B": "BG3722", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186431.0, + 272542.8 + ], + "IO": "BG3722", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1203 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3721@3": { + "A": "0", + "B": "BG3721", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187300.2, + 422818.2 + ], + "IO": "BG3721", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2205 Block 2.2.1) ", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3721@2": { + "A": "0", + "B": "BG3721", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187300.2, + 272818.2 + ], + "IO": "BG3721", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1205) ", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3783@3": { + "A": "0", + "B": "BG3783", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204393.5, + 423682.7 + ], + "IO": "BG3783", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2206) ", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3783@2": { + "A": "0", + "B": "BG3783", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204504.8, + 273714.9 + ], + "IO": "BG3783", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1206)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3784@3": { + "A": "0", + "B": "BG3784", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204390.8, + 423120.2 + ], + "IO": "BG3784", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2206) ", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3784@2": { + "A": "0", + "B": "BG3784", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204502.1, + 273114.4 + ], + "IO": "BG3784", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1206) ", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3781@3": { + "A": "0", + "B": "BG3781", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204390.8, + 422818.3 + ], + "IO": "BG3781", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2206) ", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3781@2": { + "A": "0", + "B": "BG3781", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204502.1, + 272818.3 + ], + "IO": "BG3781", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1206) ", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3780@3": { + "A": "0", + "B": "BG3780", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203432.0, + 421583.2 + ], + "IO": "BG3780", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3780@2": { + "A": "0", + "B": "BG3780", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203432.0, + 271583.2 + ], + "IO": "BG3780", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3782@3": { + "A": "0", + "B": "BG3782", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203632.9, + 422542.9 + ], + "IO": "BG3782", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2203)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3782@2": { + "A": "0", + "B": "BG3782", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203632.9, + 272542.9 + ], + "IO": "BG3782", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1203 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3816@3": { + "A": "0", + "B": "BG3816", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197951.9, + 423167.8 + ], + "IO": "BG3816", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.07", + "SPS": "3" + }, + "BG3816@2": { + "A": "0", + "B": "BG3816", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197951.9, + 273167.8 + ], + "IO": "BG3816", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.07", + "SPS": "2" + }, + "BG3815@3": { + "A": "0", + "B": "BG3815", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199151.9, + 423167.8 + ], + "IO": "BG3815", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.06", + "SPS": "3" + }, + "BG3815@2": { + "A": "0", + "B": "BG3815", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199151.9, + 273167.8 + ], + "IO": "BG3815", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.06", + "SPS": "2" + }, + "BG3814@3": { + "A": "0", + "B": "BG3814", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199951.9, + 423167.8 + ], + "IO": "BG3814", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.05", + "SPS": "3" + }, + "BG3814@2": { + "A": "0", + "B": "BG3814", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199951.9, + 273167.8 + ], + "IO": "BG3814", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.05", + "SPS": "2" + }, + "BG3813@3": { + "A": "0", + "B": "BG3813", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200751.9, + 423167.8 + ], + "IO": "BG3813", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.04", + "SPS": "3" + }, + "BG3813@2": { + "A": "0", + "B": "BG3813", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200751.9, + 273167.8 + ], + "IO": "BG3813", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.04", + "SPS": "2" + }, + "BG3812@3": { + "A": "0", + "B": "BG3812", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201551.9, + 423167.8 + ], + "IO": "BG3812", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.03", + "SPS": "3" + }, + "BG3812@2": { + "A": "0", + "B": "BG3812", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201551.9, + 273167.8 + ], + "IO": "BG3812", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.03", + "SPS": "2" + }, + "BG3811@3": { + "A": "0", + "B": "BG3811", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202351.9, + 423167.8 + ], + "IO": "BG3811", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.02", + "SPS": "3" + }, + "BG3811@2": { + "A": "0", + "B": "BG3811", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202351.9, + 273167.8 + ], + "IO": "BG3811", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.02", + "SPS": "2" + }, + "BG3810@3": { + "A": "0", + "B": "BG3810", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203151.9, + 423167.8 + ], + "IO": "BG3810", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.01", + "SPS": "3" + }, + "BG3810@2": { + "A": "0", + "B": "BG3810", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203151.9, + 273167.8 + ], + "IO": "BG3810", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.01", + "SPS": "2" + }, + "BG3823@3": { + "A": "0", + "B": "BG3823", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193901.9, + 423167.8 + ], + "IO": "BG3823", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.12", + "SPS": "3" + }, + "BG3823@2": { + "A": "0", + "B": "BG3823", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193901.9, + 273167.8 + ], + "IO": "BG3823", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.12", + "SPS": "2" + }, + "BG3822@3": { + "A": "0", + "B": "BG3822", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194701.9, + 423167.8 + ], + "IO": "BG3822", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.11", + "SPS": "3" + }, + "BG3822@2": { + "A": "0", + "B": "BG3822", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194701.9, + 273167.8 + ], + "IO": "BG3822", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.11", + "SPS": "2" + }, + "BG3821@3": { + "A": "0", + "B": "BG3821", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195501.9, + 423167.8 + ], + "IO": "BG3821", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.10", + "SPS": "3" + }, + "BG3821@2": { + "A": "0", + "B": "BG3821", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195501.9, + 273167.8 + ], + "IO": "BG3821", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.10", + "SPS": "2" + }, + "BG3820@3": { + "A": "0", + "B": "BG3820", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196301.9, + 423167.8 + ], + "IO": "BG3820", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.09", + "SPS": "3" + }, + "BG3820@2": { + "A": "0", + "B": "BG3820", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196301.9, + 273167.8 + ], + "IO": "BG3820", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.09", + "SPS": "2" + }, + "BG3817@3": { + "A": "0", + "B": "BG3817", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197101.9, + 423167.8 + ], + "IO": "BG3817", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.08", + "SPS": "3" + }, + "BG3817@2": { + "A": "0", + "B": "BG3817", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197101.9, + 273167.8 + ], + "IO": "BG3817", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.08", + "SPS": "2" + }, + "BG3824@3": { + "A": "0", + "B": "BG3824", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193101.9, + 423167.8 + ], + "IO": "BG3824", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.13", + "SPS": "3" + }, + "BG3824@2": { + "A": "0", + "B": "BG3824", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193101.9, + 273167.8 + ], + "IO": "BG3824", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.13", + "SPS": "2" + }, + "BG3826@3": { + "A": "0", + "B": "BG3826", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190501.9, + 423167.8 + ], + "IO": "BG3826", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.15", + "SPS": "3" + }, + "BG3826@2": { + "A": "0", + "B": "BG3826", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190501.9, + 273167.8 + ], + "IO": "BG3826", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.15", + "SPS": "2" + }, + "BG3825@3": { + "A": "0", + "B": "BG3825", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191301.9, + 423167.8 + ], + "IO": "BG3825", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.14", + "SPS": "3" + }, + "BG3825@2": { + "A": "0", + "B": "BG3825", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191301.9, + 273167.8 + ], + "IO": "BG3825", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.14", + "SPS": "2" + }, + "BG3827@3": { + "A": "0", + "B": "BG3827", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189701.9, + 423167.8 + ], + "IO": "BG3827", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.16", + "SPS": "3" + }, + "BG3827@2": { + "A": "0", + "B": "BG3827", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189701.9, + 273167.8 + ], + "IO": "BG3827", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.16", + "SPS": "2" + }, + "BG3830@3": { + "A": "0", + "B": "BG3830", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188901.9, + 423167.8 + ], + "IO": "BG3830", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.2.17", + "SPS": "3" + }, + "BG3830@2": { + "A": "0", + "B": "BG3830", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188901.9, + 273167.8 + ], + "IO": "BG3830", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.2.17", + "SPS": "2" + }, + "BG3843@3": { + "A": "0", + "B": "BG3843", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206544.5, + 423683.0 + ], + "IO": "BG3843", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2207) ", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3843@2": { + "A": "0", + "B": "BG3843", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206544.5, + 273738.1 + ], + "IO": "BG3843", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1207)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3844@3": { + "A": "0", + "B": "BG3844", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206541.8, + 423102.3 + ], + "IO": "BG3844", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2207) ", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3844@2": { + "A": "0", + "B": "BG3844", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206541.8, + 273108.3 + ], + "IO": "BG3844", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1207) ", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3841@3": { + "A": "0", + "B": "BG3841", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206541.8, + 422816.8 + ], + "IO": "BG3841", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2207) ", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3841@2": { + "A": "0", + "B": "BG3841", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206541.8, + 272816.8 + ], + "IO": "BG3841", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1207 Block 1.2.3) ", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3842@3": { + "A": "0", + "B": "BG3842", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207432.5, + 422541.4 + ], + "IO": "BG3842", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2204)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3842@2": { + "A": "0", + "B": "BG3842", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207432.5, + 272541.4 + ], + "IO": "BG3842", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1204 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3840@3": { + "A": "0", + "B": "BG3840", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207906.0, + 421690.2 + ], + "IO": "BG3840", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3840@2": { + "A": "0", + "B": "BG3840", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207894.6, + 271690.2 + ], + "IO": "BG3840", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3870@3": { + "A": "0", + "B": "BG3870", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208401.5, + 423166.2 + ], + "IO": "BG3870", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.01", + "SPS": "3" + }, + "BG3870@2": { + "A": "0", + "B": "BG3870", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208401.5, + 273166.2 + ], + "IO": "BG3870", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.01", + "SPS": "2" + }, + "BG3871@3": { + "A": "0", + "B": "BG3871", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209201.5, + 423166.2 + ], + "IO": "BG3871", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.02", + "SPS": "3" + }, + "BG3871@2": { + "A": "0", + "B": "BG3871", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209201.5, + 273166.2 + ], + "IO": "BG3871", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.02", + "SPS": "2" + }, + "BG3872@3": { + "A": "0", + "B": "BG3872", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210001.5, + 423166.2 + ], + "IO": "BG3872", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.03", + "SPS": "3" + }, + "BG3872@2": { + "A": "0", + "B": "BG3872", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210001.5, + 273166.2 + ], + "IO": "BG3872", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.03", + "SPS": "2" + }, + "BG3873@3": { + "A": "0", + "B": "BG3873", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211151.5, + 423166.2 + ], + "IO": "BG3873", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.04", + "SPS": "3" + }, + "BG3873@2": { + "A": "0", + "B": "BG3873", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211151.5, + 273166.2 + ], + "IO": "BG3873", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.04", + "SPS": "2" + }, + "BG3874@3": { + "A": "0", + "B": "BG3874", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211951.5, + 423166.2 + ], + "IO": "BG3874", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.05", + "SPS": "3" + }, + "BG3874@2": { + "A": "0", + "B": "BG3874", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211951.5, + 273166.2 + ], + "IO": "BG3874", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.05", + "SPS": "2" + }, + "BG3875@3": { + "A": "0", + "B": "BG3875", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212751.5, + 423166.2 + ], + "IO": "BG3875", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.06", + "SPS": "3" + }, + "BG3875@2": { + "A": "0", + "B": "BG3875", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212751.5, + 273166.2 + ], + "IO": "BG3875", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.06", + "SPS": "2" + }, + "BG3876@3": { + "A": "0", + "B": "BG3876", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213551.5, + 423166.2 + ], + "IO": "BG3876", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.07", + "SPS": "3" + }, + "BG3876@2": { + "A": "0", + "B": "BG3876", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213551.5, + 273166.2 + ], + "IO": "BG3876", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.07", + "SPS": "2" + }, + "BG3877@3": { + "A": "0", + "B": "BG3877", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214351.5, + 423166.2 + ], + "IO": "BG3877", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.08", + "SPS": "3" + }, + "BG3877@2": { + "A": "0", + "B": "BG3877", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214351.5, + 273166.2 + ], + "IO": "BG3877", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.08", + "SPS": "2" + }, + "BG3880@3": { + "A": "0", + "B": "BG3880", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215151.5, + 423166.2 + ], + "IO": "BG3880", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.09", + "SPS": "3" + }, + "BG3880@2": { + "A": "0", + "B": "BG3880", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215151.5, + 273166.2 + ], + "IO": "BG3880", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.09", + "SPS": "2" + }, + "BG3881@3": { + "A": "0", + "B": "BG3881", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217151.5, + 423166.2 + ], + "IO": "BG3881", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.10", + "SPS": "3" + }, + "BG3881@2": { + "A": "0", + "B": "BG3881", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217151.5, + 273166.2 + ], + "IO": "BG3881", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.10", + "SPS": "2" + }, + "BG3882@3": { + "A": "0", + "B": "BG3882", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217951.5, + 423166.2 + ], + "IO": "BG3882", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.11", + "SPS": "3" + }, + "BG3882@2": { + "A": "0", + "B": "BG3882", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217951.5, + 273166.2 + ], + "IO": "BG3882", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.11", + "SPS": "2" + }, + "BG3883@3": { + "A": "0", + "B": "BG3883", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218751.5, + 423166.2 + ], + "IO": "BG3883", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.12", + "SPS": "3" + }, + "BG3883@2": { + "A": "0", + "B": "BG3883", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218751.5, + 273166.2 + ], + "IO": "BG3883", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.12", + "SPS": "2" + }, + "BG3884@3": { + "A": "0", + "B": "BG3884", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219551.5, + 423166.2 + ], + "IO": "BG3884", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.13", + "SPS": "3" + }, + "BG3884@2": { + "A": "0", + "B": "BG3884", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219551.5, + 273166.2 + ], + "IO": "BG3884", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.13", + "SPS": "2" + }, + "BG3885@3": { + "A": "0", + "B": "BG3885", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220351.5, + 423166.2 + ], + "IO": "BG3885", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.14", + "SPS": "3" + }, + "BG3885@2": { + "A": "0", + "B": "BG3885", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220351.5, + 273166.2 + ], + "IO": "BG3885", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.14", + "SPS": "2" + }, + "BG3886@3": { + "A": "0", + "B": "BG3886", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221151.5, + 423166.2 + ], + "IO": "BG3886", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.15", + "SPS": "3" + }, + "BG3886@2": { + "A": "0", + "B": "BG3886", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221151.5, + 273166.2 + ], + "IO": "BG3886", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.15", + "SPS": "2" + }, + "BG3887@3": { + "A": "0", + "B": "BG3887", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221951.5, + 423166.2 + ], + "IO": "BG3887", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.16", + "SPS": "3" + }, + "BG3887@2": { + "A": "0", + "B": "BG3887", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221951.5, + 273166.2 + ], + "IO": "BG3887", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.16", + "SPS": "2" + }, + "BG3890@3": { + "A": "0", + "B": "BG3890", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223151.5, + 423166.2 + ], + "IO": "BG3890", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.17", + "SPS": "3" + }, + "BG3890@2": { + "A": "0", + "B": "BG3890", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223151.5, + 273166.2 + ], + "IO": "BG3890", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.17", + "SPS": "2" + }, + "BG3891@3": { + "A": "0", + "B": "BG3891", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223951.5, + 423166.2 + ], + "IO": "BG3891", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 18 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.18", + "SPS": "3" + }, + "BG3891@2": { + "A": "0", + "B": "BG3891", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223951.5, + 273166.2 + ], + "IO": "BG3891", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 18 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.18", + "SPS": "2" + }, + "BG3892@3": { + "A": "0", + "B": "BG3892", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224751.5, + 423166.2 + ], + "IO": "BG3892", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 19 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.19", + "SPS": "3" + }, + "BG3892@2": { + "A": "0", + "B": "BG3892", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224751.5, + 273166.2 + ], + "IO": "BG3892", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 19 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.19", + "SPS": "2" + }, + "BG3893@3": { + "A": "0", + "B": "BG3893", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225551.5, + 423166.2 + ], + "IO": "BG3893", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 20 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.20", + "SPS": "3" + }, + "BG3893@2": { + "A": "0", + "B": "BG3893", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225551.5, + 273166.2 + ], + "IO": "BG3893", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 20 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.20", + "SPS": "2" + }, + "BG3894@3": { + "A": "0", + "B": "BG3894", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226351.5, + 423166.2 + ], + "IO": "BG3894", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 21 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.3.21", + "SPS": "3" + }, + "BG3894@2": { + "A": "0", + "B": "BG3894", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226351.5, + 273166.2 + ], + "IO": "BG3894", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 21 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.3.21", + "SPS": "2" + }, + "BG3903@3": { + "A": "0", + "B": "BG3903", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227504.6, + 423678.8 + ], + "IO": "BG3903", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2208)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3903@2": { + "A": "0", + "B": "BG3903", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227504.6, + 273682.7 + ], + "IO": "BG3903", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1208) ", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3904@3": { + "A": "0", + "B": "BG3904", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 423123.6 + ], + "IO": "BG3904", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2208)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3904@2": { + "A": "0", + "B": "BG3904", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 273111.8 + ], + "IO": "BG3904", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1208) ", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3901@3": { + "A": "0", + "B": "BG3901", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 422818.2 + ], + "IO": "BG3901", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2208)) ", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3901@2": { + "A": "0", + "B": "BG3901", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 272818.2 + ], + "IO": "BG3901", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1208) ", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3902@3": { + "A": "0", + "B": "BG3902", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228273.8, + 422542.8 + ], + "IO": "BG3902", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2204)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3902@2": { + "A": "0", + "B": "BG3902", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228273.8, + 272542.8 + ], + "IO": "BG3902", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1204 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3900@3": { + "A": "0", + "B": "BG3900", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228310.7, + 421708.2 + ], + "IO": "BG3900", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-KR M2204)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3900@2": { + "A": "0", + "B": "BG3900", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228307.3, + 271624.4 + ], + "IO": "BG3900", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3915@3": { + "A": "0", + "B": "BG3915", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238553.8, + 420096.9 + ], + "IO": "BG3915", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M2209)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3905@3": { + "A": "0", + "B": "BG3905", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238013.9, + 421634.0 + ], + "IO": "BG3905", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3905@2": { + "A": "0", + "B": "BG3905", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227178.5, + 270519.9 + ], + "IO": "BG3905", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3906@3": { + "A": "0", + "B": "BG3906", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239229.7, + 421634.0 + ], + "IO": "BG3906", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2204)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3906@2": { + "A": "0", + "B": "BG3906", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227947.7, + 270789.9 + ], + "IO": "BG3906", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (M1204)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3930@3": { + "A": "0", + "B": "BG3930", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 423167.6 + ], + "IO": "BG3930", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.01", + "SPS": "3" + }, + "BG3930@2": { + "A": "0", + "B": "BG3930", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 273167.6 + ], + "IO": "BG3930", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.01", + "SPS": "2" + }, + "BG3931@3": { + "A": "0", + "B": "BG3931", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 423167.6 + ], + "IO": "BG3931", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.02", + "SPS": "3" + }, + "BG3931@2": { + "A": "0", + "B": "BG3931", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 273167.6 + ], + "IO": "BG3931", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.02", + "SPS": "2" + }, + "BG3932@3": { + "A": "0", + "B": "BG3932", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 423167.6 + ], + "IO": "BG3932", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.03", + "SPS": "3" + }, + "BG3932@2": { + "A": "0", + "B": "BG3932", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 273167.6 + ], + "IO": "BG3932", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.03", + "SPS": "2" + }, + "BG3933@3": { + "A": "0", + "B": "BG3933", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 423167.6 + ], + "IO": "BG3933", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.04", + "SPS": "3" + }, + "BG3933@2": { + "A": "0", + "B": "BG3933", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 273167.6 + ], + "IO": "BG3933", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.04", + "SPS": "2" + }, + "BG3934@3": { + "A": "0", + "B": "BG3934", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 423167.6 + ], + "IO": "BG3934", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.05", + "SPS": "3" + }, + "BG3934@2": { + "A": "0", + "B": "BG3934", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 273167.6 + ], + "IO": "BG3934", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.05", + "SPS": "2" + }, + "BG3935@3": { + "A": "0", + "B": "BG3935", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 423167.6 + ], + "IO": "BG3935", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.06", + "SPS": "3" + }, + "BG3935@2": { + "A": "0", + "B": "BG3935", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 273167.6 + ], + "IO": "BG3935", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.06", + "SPS": "2" + }, + "BG3936@3": { + "A": "0", + "B": "BG3936", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 423167.6 + ], + "IO": "BG3936", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.07", + "SPS": "3" + }, + "BG3936@2": { + "A": "0", + "B": "BG3936", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 273167.6 + ], + "IO": "BG3936", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.07", + "SPS": "2" + }, + "BG3937@3": { + "A": "0", + "B": "BG3937", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 423167.6 + ], + "IO": "BG3937", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.08", + "SPS": "3" + }, + "BG3937@2": { + "A": "0", + "B": "BG3937", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 273167.6 + ], + "IO": "BG3937", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.08", + "SPS": "2" + }, + "BG3940@3": { + "A": "0", + "B": "BG3940", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 423167.6 + ], + "IO": "BG3940", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.09", + "SPS": "3" + }, + "BG3940@2": { + "A": "0", + "B": "BG3940", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 273167.6 + ], + "IO": "BG3940", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.09", + "SPS": "2" + }, + "BG3941@3": { + "A": "0", + "B": "BG3941", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 423167.6 + ], + "IO": "BG3941", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.10", + "SPS": "3" + }, + "BG3941@2": { + "A": "0", + "B": "BG3941", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 273167.6 + ], + "IO": "BG3941", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.10", + "SPS": "2" + }, + "BG3942@3": { + "A": "0", + "B": "BG3942", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 423167.6 + ], + "IO": "BG3942", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.11", + "SPS": "3" + }, + "BG3942@2": { + "A": "0", + "B": "BG3942", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 273167.6 + ], + "IO": "BG3942", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.11", + "SPS": "2" + }, + "BG3943@3": { + "A": "0", + "B": "BG3943", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 423167.6 + ], + "IO": "BG3943", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.12", + "SPS": "3" + }, + "BG3943@2": { + "A": "0", + "B": "BG3943", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 273167.6 + ], + "IO": "BG3943", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.12", + "SPS": "2" + }, + "BG3944@3": { + "A": "0", + "B": "BG3944", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239150.0, + 423167.6 + ], + "IO": "BG3944", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.2.4.13", + "SPS": "3" + }, + "BG3944@2": { + "A": "0", + "B": "BG3944", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239150.0, + 273167.6 + ], + "IO": "BG3944", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.4.13", + "SPS": "2" + }, + "BG4012@3": { + "A": "0", + "B": "BG4012", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 416041.9 + ], + "IO": "BG4012", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "In Separator 19 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.19", + "SPS": "3" + }, + "BG4012@2": { + "A": "0", + "B": "BG4012", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 266041.9 + ], + "IO": "BG4012", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "In Separator 19 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.19", + "SPS": "2" + }, + "BG4003@3": { + "A": "0", + "B": "BG4003", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 416041.9 + ], + "IO": "BG4003", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.12", + "SPS": "3" + }, + "BG4003@2": { + "A": "0", + "B": "BG4003", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 266041.9 + ], + "IO": "BG4003", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.12", + "SPS": "2" + }, + "BG4002@3": { + "A": "0", + "B": "BG4002", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 416041.9 + ], + "IO": "BG4002", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.11", + "SPS": "3" + }, + "BG4002@2": { + "A": "0", + "B": "BG4002", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 266041.9 + ], + "IO": "BG4002", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.11", + "SPS": "2" + }, + "BG4001@3": { + "A": "0", + "B": "BG4001", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 416041.9 + ], + "IO": "BG4001", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.10", + "SPS": "3" + }, + "BG4001@2": { + "A": "0", + "B": "BG4001", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 266041.9 + ], + "IO": "BG4001", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.10", + "SPS": "2" + }, + "BG4000@3": { + "A": "0", + "B": "BG4000", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 416041.9 + ], + "IO": "BG4000", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.09", + "SPS": "3" + }, + "BG4000@2": { + "A": "0", + "B": "BG4000", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 266041.9 + ], + "IO": "BG4000", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.09", + "SPS": "2" + }, + "BG3997@3": { + "A": "0", + "B": "BG3997", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 416041.9 + ], + "IO": "BG3997", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.08", + "SPS": "3" + }, + "BG3997@2": { + "A": "0", + "B": "BG3997", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 266041.9 + ], + "IO": "BG3997", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.08", + "SPS": "2" + }, + "BG4006@3": { + "A": "0", + "B": "BG4006", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 416041.9 + ], + "IO": "BG4006", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.15", + "SPS": "3" + }, + "BG4006@2": { + "A": "0", + "B": "BG4006", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 266041.9 + ], + "IO": "BG4006", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.15", + "SPS": "2" + }, + "BG4005@3": { + "A": "0", + "B": "BG4005", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 416041.9 + ], + "IO": "BG4005", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.14", + "SPS": "3" + }, + "BG4005@2": { + "A": "0", + "B": "BG4005", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 266041.9 + ], + "IO": "BG4005", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.14", + "SPS": "2" + }, + "BG4004@3": { + "A": "0", + "B": "BG4004", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 416041.9 + ], + "IO": "BG4004", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.13", + "SPS": "3" + }, + "BG4004@2": { + "A": "0", + "B": "BG4004", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 266041.9 + ], + "IO": "BG4004", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.13", + "SPS": "2" + }, + "BG4007@3": { + "A": "0", + "B": "BG4007", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 416041.9 + ], + "IO": "BG4007", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.16", + "SPS": "3" + }, + "BG4007@2": { + "A": "0", + "B": "BG4007", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 266041.9 + ], + "IO": "BG4007", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.16", + "SPS": "2" + }, + "BG4011@3": { + "A": "0", + "B": "BG4011", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 416041.9 + ], + "IO": "BG4011", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 18 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.18", + "SPS": "3" + }, + "BG4011@2": { + "A": "0", + "B": "BG4011", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 266041.9 + ], + "IO": "BG4011", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 18 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.18", + "SPS": "2" + }, + "BG4010@3": { + "A": "0", + "B": "BG4010", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 416041.9 + ], + "IO": "BG4010", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.17", + "SPS": "3" + }, + "BG4010@2": { + "A": "0", + "B": "BG4010", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 266041.9 + ], + "IO": "BG4010", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.17", + "SPS": "2" + }, + "BG3996@3": { + "A": "0", + "B": "BG3996", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 416041.9 + ], + "IO": "BG3996", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.07", + "SPS": "3" + }, + "BG3996@2": { + "A": "0", + "B": "BG3996", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 266041.9 + ], + "IO": "BG3996", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.07", + "SPS": "2" + }, + "BG3995@3": { + "A": "0", + "B": "BG3995", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 416041.9 + ], + "IO": "BG3995", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.06", + "SPS": "3" + }, + "BG3995@2": { + "A": "0", + "B": "BG3995", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 266041.9 + ], + "IO": "BG3995", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.06", + "SPS": "2" + }, + "BG3994@3": { + "A": "0", + "B": "BG3994", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 416041.9 + ], + "IO": "BG3994", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.05", + "SPS": "3" + }, + "BG3994@2": { + "A": "0", + "B": "BG3994", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 266041.9 + ], + "IO": "BG3994", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.05", + "SPS": "2" + }, + "BG3993@3": { + "A": "0", + "B": "BG3993", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 416041.9 + ], + "IO": "BG3993", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.04", + "SPS": "3" + }, + "BG3993@2": { + "A": "0", + "B": "BG3993", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 266041.9 + ], + "IO": "BG3993", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.04", + "SPS": "2" + }, + "BG3992@3": { + "A": "0", + "B": "BG3992", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 416041.9 + ], + "IO": "BG3992", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.03", + "SPS": "3" + }, + "BG3992@2": { + "A": "0", + "B": "BG3992", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 266041.9 + ], + "IO": "BG3992", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.03", + "SPS": "2" + }, + "BG3991@3": { + "A": "0", + "B": "BG3991", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 416041.9 + ], + "IO": "BG3991", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.02", + "SPS": "3" + }, + "BG3991@2": { + "A": "0", + "B": "BG3991", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 266041.9 + ], + "IO": "BG3991", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.02", + "SPS": "2" + }, + "BG3990@3": { + "A": "0", + "B": "BG3990", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 416041.9 + ], + "IO": "BG3990", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.01", + "SPS": "3" + }, + "BG3990@2": { + "A": "0", + "B": "BG3990", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 266041.9 + ], + "IO": "BG3990", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.01", + "SPS": "2" + }, + "BG3960@3": { + "A": "0", + "B": "BG3960", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186488.6, + 416652.0 + ], + "IO": "BG3960", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3960@2": { + "A": "0", + "B": "BG3960", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186488.6, + 266652.0 + ], + "IO": "BG3960", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1305)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3962@3": { + "A": "0", + "B": "BG3962", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186431.0, + 417635.3 + ], + "IO": "BG3962", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2301)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3962@2": { + "A": "0", + "B": "BG3962", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186431.0, + 267635.3 + ], + "IO": "BG3962", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1301 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3963@3": { + "A": "0", + "B": "BG3963", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187184.5, + 415493.4 + ], + "IO": "BG3963", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2305) ", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3963@2": { + "A": "0", + "B": "BG3963", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187184.5, + 265484.7 + ], + "IO": "BG3963", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1305)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3964@3": { + "A": "0", + "B": "BG3964", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187179.7, + 415788.0 + ], + "IO": "BG3964", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2305) ", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3964@2": { + "A": "0", + "B": "BG3964", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187179.7, + 265780.8 + ], + "IO": "BG3964", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1305) ", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3961@3": { + "A": "0", + "B": "BG3961", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187179.7, + 416348.9 + ], + "IO": "BG3961", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2305) ", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3961@2": { + "A": "0", + "B": "BG3961", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187179.7, + 266348.9 + ], + "IO": "BG3961", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1305) ", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4056@3": { + "A": "0", + "B": "BG4056", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 416041.9 + ], + "IO": "BG4056", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.07", + "SPS": "3" + }, + "BG4056@2": { + "A": "0", + "B": "BG4056", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 266041.9 + ], + "IO": "BG4056", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.07", + "SPS": "2" + }, + "BG4055@3": { + "A": "0", + "B": "BG4055", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 416041.9 + ], + "IO": "BG4055", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.06", + "SPS": "3" + }, + "BG4055@2": { + "A": "0", + "B": "BG4055", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 266041.9 + ], + "IO": "BG4055", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.06", + "SPS": "2" + }, + "BG4054@3": { + "A": "0", + "B": "BG4054", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 416041.9 + ], + "IO": "BG4054", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.05", + "SPS": "3" + }, + "BG4054@2": { + "A": "0", + "B": "BG4054", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 266041.9 + ], + "IO": "BG4054", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.05", + "SPS": "2" + }, + "BG4053@3": { + "A": "0", + "B": "BG4053", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.0, + 416041.9 + ], + "IO": "BG4053", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.04", + "SPS": "3" + }, + "BG4053@2": { + "A": "0", + "B": "BG4053", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.0, + 266041.9 + ], + "IO": "BG4053", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.04", + "SPS": "2" + }, + "BG4052@3": { + "A": "0", + "B": "BG4052", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 416041.9 + ], + "IO": "BG4052", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.03", + "SPS": "3" + }, + "BG4052@2": { + "A": "0", + "B": "BG4052", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 266041.9 + ], + "IO": "BG4052", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.03", + "SPS": "2" + }, + "BG4051@3": { + "A": "0", + "B": "BG4051", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 416041.9 + ], + "IO": "BG4051", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.02", + "SPS": "3" + }, + "BG4051@2": { + "A": "0", + "B": "BG4051", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 266041.9 + ], + "IO": "BG4051", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.02", + "SPS": "2" + }, + "BG4050@3": { + "A": "0", + "B": "BG4050", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 416041.9 + ], + "IO": "BG4050", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.01", + "SPS": "3" + }, + "BG4050@2": { + "A": "0", + "B": "BG4050", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 266041.9 + ], + "IO": "BG4050", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.01", + "SPS": "2" + }, + "BG4020@3": { + "A": "0", + "B": "BG4020", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203688.6, + 416652.0 + ], + "IO": "BG4020", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4020@2": { + "A": "0", + "B": "BG4020", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203688.6, + 266652.0 + ], + "IO": "BG4020", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-KR M1301)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4022@3": { + "A": "0", + "B": "BG4022", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203282.3, + 417635.3 + ], + "IO": "BG4022", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2301 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4022@2": { + "A": "0", + "B": "BG4022", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203282.3, + 267635.3 + ], + "IO": "BG4022", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1301 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4023@3": { + "A": "0", + "B": "BG4023", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204382.4, + 415481.7 + ], + "IO": "BG4023", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2206) ", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4023@2": { + "A": "0", + "B": "BG4023", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204384.5, + 265493.9 + ], + "IO": "BG4023", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1306) ", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4024@3": { + "A": "0", + "B": "BG4024", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204379.8, + 415789.7 + ], + "IO": "BG4024", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2206) ", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4024@2": { + "A": "0", + "B": "BG4024", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204379.8, + 265787.3 + ], + "IO": "BG4024", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1306)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4021@3": { + "A": "0", + "B": "BG4021", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204379.8, + 416348.9 + ], + "IO": "BG4021", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2306) ", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4021@2": { + "A": "0", + "B": "BG4021", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204379.8, + 266348.9 + ], + "IO": "BG4021", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1306) ", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4063@3": { + "A": "0", + "B": "BG4063", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193949.9, + 416041.9 + ], + "IO": "BG4063", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.12", + "SPS": "3" + }, + "BG4063@2": { + "A": "0", + "B": "BG4063", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193949.9, + 266041.9 + ], + "IO": "BG4063", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.12", + "SPS": "2" + }, + "BG4062@3": { + "A": "0", + "B": "BG4062", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194749.9, + 416041.9 + ], + "IO": "BG4062", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.11", + "SPS": "3" + }, + "BG4062@2": { + "A": "0", + "B": "BG4062", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194749.9, + 266041.9 + ], + "IO": "BG4062", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.11", + "SPS": "2" + }, + "BG4061@3": { + "A": "0", + "B": "BG4061", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195549.9, + 416041.9 + ], + "IO": "BG4061", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.10", + "SPS": "3" + }, + "BG4061@2": { + "A": "0", + "B": "BG4061", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195549.9, + 266041.9 + ], + "IO": "BG4061", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.10", + "SPS": "2" + }, + "BG4060@3": { + "A": "0", + "B": "BG4060", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196349.9, + 416041.9 + ], + "IO": "BG4060", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.09", + "SPS": "3" + }, + "BG4060@2": { + "A": "0", + "B": "BG4060", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196349.9, + 266041.9 + ], + "IO": "BG4060", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.09", + "SPS": "2" + }, + "BG4057@3": { + "A": "0", + "B": "BG4057", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197149.9, + 416041.9 + ], + "IO": "BG4057", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.08", + "SPS": "3" + }, + "BG4057@2": { + "A": "0", + "B": "BG4057", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197149.9, + 266041.9 + ], + "IO": "BG4057", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.08", + "SPS": "2" + }, + "BG4064@3": { + "A": "0", + "B": "BG4064", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193149.9, + 416041.9 + ], + "IO": "BG4064", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.13", + "SPS": "3" + }, + "BG4064@2": { + "A": "0", + "B": "BG4064", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193149.9, + 266041.9 + ], + "IO": "BG4064", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.13", + "SPS": "2" + }, + "BG4066@3": { + "A": "0", + "B": "BG4066", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 416041.9 + ], + "IO": "BG4066", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.15", + "SPS": "3" + }, + "BG4066@2": { + "A": "0", + "B": "BG4066", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 266041.9 + ], + "IO": "BG4066", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.15", + "SPS": "2" + }, + "BG4065@3": { + "A": "0", + "B": "BG4065", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 416041.9 + ], + "IO": "BG4065", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.14", + "SPS": "3" + }, + "BG4065@2": { + "A": "0", + "B": "BG4065", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 266041.9 + ], + "IO": "BG4065", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.14", + "SPS": "2" + }, + "BG4067@3": { + "A": "0", + "B": "BG4067", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.0, + 416041.9 + ], + "IO": "BG4067", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.16", + "SPS": "3" + }, + "BG4067@2": { + "A": "0", + "B": "BG4067", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.0, + 266041.9 + ], + "IO": "BG4067", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.16", + "SPS": "2" + }, + "BG4070@3": { + "A": "0", + "B": "BG4070", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 416041.9 + ], + "IO": "BG4070", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.17", + "SPS": "3" + }, + "BG4070@2": { + "A": "0", + "B": "BG4070", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 266041.9 + ], + "IO": "BG4070", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.17", + "SPS": "2" + }, + "BG4083@3": { + "A": "0", + "B": "BG4083", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206553.0, + 415488.1 + ], + "IO": "BG4083", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (Block 2.3.3) ", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4083@2": { + "A": "0", + "B": "BG4083", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206442.7, + 265495.6 + ], + "IO": "BG4083", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1307)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4084@3": { + "A": "0", + "B": "BG4084", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206548.3, + 415788.7 + ], + "IO": "BG4084", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M2308 Block 2.3.3) ", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4084@2": { + "A": "0", + "B": "BG4084", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206437.9, + 265788.4 + ], + "IO": "BG4084", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1307) ", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4081@3": { + "A": "0", + "B": "BG4081", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206548.3, + 416348.9 + ], + "IO": "BG4081", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2308 Block 2.3.3) ", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4081@2": { + "A": "0", + "B": "BG4081", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206437.9, + 266348.9 + ], + "IO": "BG4081", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1307) ", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4080@3": { + "A": "0", + "B": "BG4080", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207201.6, + 416652.0 + ], + "IO": "BG4080", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4080@2": { + "A": "0", + "B": "BG4080", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207201.6, + 266652.0 + ], + "IO": "BG4080", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1302)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4082@3": { + "A": "0", + "B": "BG4082", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207420.0, + 417635.3 + ], + "IO": "BG4082", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2302 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4082@2": { + "A": "0", + "B": "BG4082", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207420.0, + 267635.3 + ], + "IO": "BG4082", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1302 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4110@3": { + "A": "0", + "B": "BG4110", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208401.5, + 416053.7 + ], + "IO": "BG4110", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.01", + "SPS": "3" + }, + "BG4110@2": { + "A": "0", + "B": "BG4110", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208401.5, + 266053.7 + ], + "IO": "BG4110", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.01", + "SPS": "2" + }, + "BG4111@3": { + "A": "0", + "B": "BG4111", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209201.5, + 416053.7 + ], + "IO": "BG4111", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.02", + "SPS": "3" + }, + "BG4111@2": { + "A": "0", + "B": "BG4111", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209201.5, + 266053.7 + ], + "IO": "BG4111", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.02", + "SPS": "2" + }, + "BG4112@3": { + "A": "0", + "B": "BG4112", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210001.5, + 416053.7 + ], + "IO": "BG4112", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.03", + "SPS": "3" + }, + "BG4112@2": { + "A": "0", + "B": "BG4112", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210001.5, + 266053.7 + ], + "IO": "BG4112", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.03", + "SPS": "2" + }, + "BG4113@3": { + "A": "0", + "B": "BG4113", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211151.5, + 416053.7 + ], + "IO": "BG4113", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.04", + "SPS": "3" + }, + "BG4113@2": { + "A": "0", + "B": "BG4113", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211151.5, + 266053.7 + ], + "IO": "BG4113", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.04", + "SPS": "2" + }, + "BG4114@3": { + "A": "0", + "B": "BG4114", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211951.5, + 416053.7 + ], + "IO": "BG4114", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.05", + "SPS": "3" + }, + "BG4114@2": { + "A": "0", + "B": "BG4114", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211951.5, + 266053.7 + ], + "IO": "BG4114", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.05", + "SPS": "2" + }, + "BG4115@3": { + "A": "0", + "B": "BG4115", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212751.5, + 416053.7 + ], + "IO": "BG4115", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.06", + "SPS": "3" + }, + "BG4115@2": { + "A": "0", + "B": "BG4115", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212751.5, + 266053.7 + ], + "IO": "BG4115", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.06", + "SPS": "2" + }, + "BG4116@3": { + "A": "0", + "B": "BG4116", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213551.5, + 416053.7 + ], + "IO": "BG4116", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.07", + "SPS": "3" + }, + "BG4116@2": { + "A": "0", + "B": "BG4116", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213551.5, + 266053.7 + ], + "IO": "BG4116", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.07", + "SPS": "2" + }, + "BG4117@3": { + "A": "0", + "B": "BG4117", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214351.5, + 416053.7 + ], + "IO": "BG4117", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.08", + "SPS": "3" + }, + "BG4117@2": { + "A": "0", + "B": "BG4117", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214351.5, + 266053.7 + ], + "IO": "BG4117", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.08", + "SPS": "2" + }, + "BG4120@3": { + "A": "0", + "B": "BG4120", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215151.5, + 416053.7 + ], + "IO": "BG4120", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.09", + "SPS": "3" + }, + "BG4120@2": { + "A": "0", + "B": "BG4120", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215151.5, + 266053.7 + ], + "IO": "BG4120", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.09", + "SPS": "2" + }, + "BG4121@3": { + "A": "0", + "B": "BG4121", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217151.5, + 416053.7 + ], + "IO": "BG4121", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.10", + "SPS": "3" + }, + "BG4121@2": { + "A": "0", + "B": "BG4121", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217151.5, + 266053.7 + ], + "IO": "BG4121", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.10", + "SPS": "2" + }, + "BG4122@3": { + "A": "0", + "B": "BG4122", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217951.5, + 416053.7 + ], + "IO": "BG4122", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.11", + "SPS": "3" + }, + "BG4122@2": { + "A": "0", + "B": "BG4122", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217951.5, + 266053.7 + ], + "IO": "BG4122", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.11", + "SPS": "2" + }, + "BG4123@3": { + "A": "0", + "B": "BG4123", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218751.5, + 416053.7 + ], + "IO": "BG4123", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.12", + "SPS": "3" + }, + "BG4123@2": { + "A": "0", + "B": "BG4123", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218751.5, + 266053.7 + ], + "IO": "BG4123", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.12", + "SPS": "2" + }, + "BG4124@3": { + "A": "0", + "B": "BG4124", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219551.5, + 416053.7 + ], + "IO": "BG4124", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.13", + "SPS": "3" + }, + "BG4124@2": { + "A": "0", + "B": "BG4124", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219551.5, + 266053.7 + ], + "IO": "BG4124", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.13", + "SPS": "2" + }, + "BG4125@3": { + "A": "0", + "B": "BG4125", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220351.5, + 416053.7 + ], + "IO": "BG4125", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.14", + "SPS": "3" + }, + "BG4125@2": { + "A": "0", + "B": "BG4125", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220351.5, + 266053.7 + ], + "IO": "BG4125", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.14", + "SPS": "2" + }, + "BG4126@3": { + "A": "0", + "B": "BG4126", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221151.5, + 416053.7 + ], + "IO": "BG4126", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.15", + "SPS": "3" + }, + "BG4126@2": { + "A": "0", + "B": "BG4126", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221151.5, + 266053.7 + ], + "IO": "BG4126", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.15", + "SPS": "2" + }, + "BG4127@3": { + "A": "0", + "B": "BG4127", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221951.5, + 416053.7 + ], + "IO": "BG4127", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.16", + "SPS": "3" + }, + "BG4127@2": { + "A": "0", + "B": "BG4127", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221951.5, + 266053.7 + ], + "IO": "BG4127", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.16", + "SPS": "2" + }, + "BG4130@3": { + "A": "0", + "B": "BG4130", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223151.5, + 416053.7 + ], + "IO": "BG4130", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.17", + "SPS": "3" + }, + "BG4130@2": { + "A": "0", + "B": "BG4130", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223151.5, + 266053.7 + ], + "IO": "BG4130", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.17", + "SPS": "2" + }, + "BG4131@3": { + "A": "0", + "B": "BG4131", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223951.5, + 416053.7 + ], + "IO": "BG4131", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 18 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.18", + "SPS": "3" + }, + "BG4131@2": { + "A": "0", + "B": "BG4131", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223951.5, + 266053.7 + ], + "IO": "BG4131", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 18 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.18", + "SPS": "2" + }, + "BG4132@3": { + "A": "0", + "B": "BG4132", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224751.5, + 416053.7 + ], + "IO": "BG4132", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 19 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.19", + "SPS": "3" + }, + "BG4132@2": { + "A": "0", + "B": "BG4132", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224751.5, + 266053.7 + ], + "IO": "BG4132", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 19 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.19", + "SPS": "2" + }, + "BG4133@3": { + "A": "0", + "B": "BG4133", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225551.5, + 416053.7 + ], + "IO": "BG4133", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 20 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.20", + "SPS": "3" + }, + "BG4133@2": { + "A": "0", + "B": "BG4133", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225551.5, + 266053.7 + ], + "IO": "BG4133", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 20 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.20", + "SPS": "2" + }, + "BG4134@3": { + "A": "0", + "B": "BG4134", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226351.5, + 416053.7 + ], + "IO": "BG4134", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 21 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.21", + "SPS": "3" + }, + "BG4134@2": { + "A": "0", + "B": "BG4134", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226351.5, + 266053.7 + ], + "IO": "BG4134", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 21 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.21", + "SPS": "2" + }, + "BG4090@3": { + "A": "0", + "B": "BG4090", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225234.4, + 418570.0 + ], + "IO": "BG4090", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV 2309)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4090@2": { + "A": "0", + "B": "BG4090", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205993.6, + 268602.8 + ], + "IO": "BG4090", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS-KR-M1302)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4085@3": { + "A": "0", + "B": "BG4085", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225376.4, + 417529.0 + ], + "IO": "BG4085", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4085@2": { + "A": "0", + "B": "BG4085", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214411.0, + 268497.6 + ], + "IO": "BG4085", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (ILS-KR-M1302)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4086@3": { + "A": "0", + "B": "BG4086", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206736.1, + 418332.8 + ], + "IO": "BG4086", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (M2302)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4086@2": { + "A": "0", + "B": "BG4086", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215211.2, + 268497.6 + ], + "IO": "BG4086", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (M1302)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4143@3": { + "A": "0", + "B": "BG4143", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227442.7, + 415493.8 + ], + "IO": "BG4143", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2308)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4143@2": { + "A": "0", + "B": "BG4143", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227442.7, + 265490.2 + ], + "IO": "BG4143", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1308) ", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4144@3": { + "A": "0", + "B": "BG4144", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227438.0, + 415787.7 + ], + "IO": "BG4144", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2308)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4144@2": { + "A": "0", + "B": "BG4144", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227438.0, + 265786.5 + ], + "IO": "BG4144", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1308) ", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4141@3": { + "A": "0", + "B": "BG4141", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227438.0, + 416348.9 + ], + "IO": "BG4141", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2308)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4141@2": { + "A": "0", + "B": "BG4141", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227438.0, + 266348.9 + ], + "IO": "BG4141", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M1308) ", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4140@3": { + "A": "0", + "B": "BG4140", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228201.6, + 416652.0 + ], + "IO": "BG4140", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4140@2": { + "A": "0", + "B": "BG4140", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228201.6, + 266652.0 + ], + "IO": "BG4140", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4142@3": { + "A": "0", + "B": "BG4142", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228420.0, + 417635.3 + ], + "IO": "BG4142", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2302 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4142@2": { + "A": "0", + "B": "BG4142", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228420.0, + 267635.3 + ], + "IO": "BG4142", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1302 nach BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4170@3": { + "A": "0", + "B": "BG4170", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229151.5, + 416053.7 + ], + "IO": "BG4170", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.01", + "SPS": "3" + }, + "BG4170@2": { + "A": "0", + "B": "BG4170", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229151.5, + 266053.7 + ], + "IO": "BG4170", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.01", + "SPS": "2" + }, + "BG4171@3": { + "A": "0", + "B": "BG4171", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229951.5, + 416053.7 + ], + "IO": "BG4171", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.02", + "SPS": "3" + }, + "BG4171@2": { + "A": "0", + "B": "BG4171", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229951.5, + 266053.7 + ], + "IO": "BG4171", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.02", + "SPS": "2" + }, + "BG4172@3": { + "A": "0", + "B": "BG4172", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230751.5, + 416053.7 + ], + "IO": "BG4172", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.03", + "SPS": "3" + }, + "BG4172@2": { + "A": "0", + "B": "BG4172", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230751.5, + 266053.7 + ], + "IO": "BG4172", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.03", + "SPS": "2" + }, + "BG4173@3": { + "A": "0", + "B": "BG4173", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 416053.7 + ], + "IO": "BG4173", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.04", + "SPS": "3" + }, + "BG4173@2": { + "A": "0", + "B": "BG4173", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 266053.7 + ], + "IO": "BG4173", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.04", + "SPS": "2" + }, + "BG4174@3": { + "A": "0", + "B": "BG4174", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 416053.7 + ], + "IO": "BG4174", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.05", + "SPS": "3" + }, + "BG4174@2": { + "A": "0", + "B": "BG4174", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 266053.7 + ], + "IO": "BG4174", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.05", + "SPS": "2" + }, + "BG4175@3": { + "A": "0", + "B": "BG4175", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 416053.7 + ], + "IO": "BG4175", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.06", + "SPS": "3" + }, + "BG4175@2": { + "A": "0", + "B": "BG4175", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 266053.7 + ], + "IO": "BG4175", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 6 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.06", + "SPS": "2" + }, + "BG4176@3": { + "A": "0", + "B": "BG4176", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 416053.7 + ], + "IO": "BG4176", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.07", + "SPS": "3" + }, + "BG4176@2": { + "A": "0", + "B": "BG4176", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 266053.7 + ], + "IO": "BG4176", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 7 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.07", + "SPS": "2" + }, + "BG4177@3": { + "A": "0", + "B": "BG4177", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 416053.7 + ], + "IO": "BG4177", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.08", + "SPS": "3" + }, + "BG4177@2": { + "A": "0", + "B": "BG4177", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 266053.7 + ], + "IO": "BG4177", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 8 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.08", + "SPS": "2" + }, + "BG4180@3": { + "A": "0", + "B": "BG4180", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 416053.7 + ], + "IO": "BG4180", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.09", + "SPS": "3" + }, + "BG4180@2": { + "A": "0", + "B": "BG4180", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 266053.7 + ], + "IO": "BG4180", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 9 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.09", + "SPS": "2" + }, + "BG4181@3": { + "A": "0", + "B": "BG4181", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236751.5, + 416053.7 + ], + "IO": "BG4181", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.10", + "SPS": "3" + }, + "BG4181@2": { + "A": "0", + "B": "BG4181", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236751.5, + 266053.7 + ], + "IO": "BG4181", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 10 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.10", + "SPS": "2" + }, + "BG4182@3": { + "A": "0", + "B": "BG4182", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237551.5, + 416053.7 + ], + "IO": "BG4182", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.11", + "SPS": "3" + }, + "BG4182@2": { + "A": "0", + "B": "BG4182", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237551.5, + 266053.7 + ], + "IO": "BG4182", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 11 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.11", + "SPS": "2" + }, + "BG4183@3": { + "A": "0", + "B": "BG4183", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238351.5, + 416053.7 + ], + "IO": "BG4183", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.12", + "SPS": "3" + }, + "BG4183@2": { + "A": "0", + "B": "BG4183", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238351.5, + 266053.7 + ], + "IO": "BG4183", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 12 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.12", + "SPS": "2" + }, + "BG4184@3": { + "A": "0", + "B": "BG4184", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239151.5, + 416053.7 + ], + "IO": "BG4184", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.13", + "SPS": "3" + }, + "BG4184@2": { + "A": "0", + "B": "BG4184", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239151.5, + 266053.7 + ], + "IO": "BG4184", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 13 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.13", + "SPS": "2" + }, + "MA0262@3": { + "A": "0", + "B": "MA0262", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187037.5, + 401290.4 + ], + "IO": "MA0262", + "ID": "9999", + "VERW": "ILS-CV 2305", + "BEZEICHNUNG": "Motor MA0262 (CV-M2305)", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0262@2": { + "A": "0", + "B": "MA0262", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187034.4, + 251287.7 + ], + "IO": "MA0262", + "ID": "9999", + "VERW": "ILS-CV-M1305", + "BEZEICHNUNG": "Motor MA0262 (CV-M1305)", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0260@3": { + "A": "0", + "B": "MA0260", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 169288.7, + 398393.0 + ], + "IO": "MA0260", + "ID": "9999", + "VERW": "ILS-KR M2303", + "BEZEICHNUNG": "Motor MA0260 (KR-M2303)", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0260@2": { + "A": "0", + "B": "MA0260", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 169341.8, + 248390.3 + ], + "IO": "MA0260", + "ID": "9999", + "VERW": "ILS-KR-M1303", + "BEZEICHNUNG": "Motor MA0260 (KR-M1303)", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4200@3": { + "A": "0", + "B": "BG4200", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187526.0, + 398861.1 + ], + "IO": "BG4200", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4200@2": { + "A": "0", + "B": "BG4200", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187526.0, + 248861.1 + ], + "IO": "BG4200", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4204@3": { + "A": "0", + "B": "BG4204", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187034.5, + 400417.1 + ], + "IO": "BG4204", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV 2305)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4204@2": { + "A": "0", + "B": "BG4204", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187034.5, + 250417.1 + ], + "IO": "BG4204", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV 1305)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4205@3": { + "A": "0", + "B": "BG4205", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187034.8, + 400991.5 + ], + "IO": "BG4205", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV 2305)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4205@2": { + "A": "0", + "B": "BG4205", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187034.8, + 250991.5 + ], + "IO": "BG4205", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K1305)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4207@3": { + "A": "0", + "B": "BG4207", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183191.4, + 398859.2 + ], + "IO": "BG4207", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K2303 Einfahrt Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4207@2": { + "A": "0", + "B": "BG4207", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183191.4, + 248859.2 + ], + "IO": "BG4207", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1303 Einfahrt Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4210@3": { + "A": "0", + "B": "BG4210", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178799.9, + 398853.8 + ], + "IO": "BG4210", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2303 Einfahrt Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4210@2": { + "A": "0", + "B": "BG4210", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178799.9, + 248853.8 + ], + "IO": "BG4210", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1303 Einfahrt Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4211@3": { + "A": "0", + "B": "BG4211", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175587.3, + 398853.8 + ], + "IO": "BG4211", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K2303 Einfahrt Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4211@2": { + "A": "0", + "B": "BG4211", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175587.3, + 248853.8 + ], + "IO": "BG4211", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1303 Einfahrt Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4212@3": { + "A": "0", + "B": "BG4212", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172113.1, + 398853.8 + ], + "IO": "BG4212", + "ID": "", + "VERW": "Sync P5", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K2303 Einfahrt Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4212@2": { + "A": "0", + "B": "BG4212", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172113.1, + 248853.8 + ], + "IO": "BG4212", + "ID": "", + "VERW": "Sync P5", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K1303 Einfahrt Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4201@3": { + "A": "0", + "B": "BG4201", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186867.8, + 400094.2 + ], + "IO": "BG4201", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2303 ) Block 2.3.1", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4201@2": { + "A": "0", + "B": "BG4201", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186612.9, + 250119.4 + ], + "IO": "BG4201", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1303 ) Block 1.3.1", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4202@3": { + "A": "0", + "B": "BG4202", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186307.2, + 399824.2 + ], + "IO": "BG4202", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K2303 Einfahrt Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4202@2": { + "A": "0", + "B": "BG4202", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186359.6, + 249824.2 + ], + "IO": "BG4202", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1303 Einfahrt Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4252@3": { + "A": "0", + "B": "BG4252", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 400198.5 + ], + "IO": "BG4252", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.19 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.19", + "SPS": "3" + }, + "BG4252@2": { + "A": "0", + "B": "BG4252", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 250198.5 + ], + "IO": "BG4252", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.19 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.19", + "SPS": "2" + }, + "BG4251@3": { + "A": "0", + "B": "BG4251", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170799.9, + 400198.7 + ], + "IO": "BG4251", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.18 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.18", + "SPS": "3" + }, + "BG4251@2": { + "A": "0", + "B": "BG4251", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170799.9, + 250198.7 + ], + "IO": "BG4251", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.18 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.18", + "SPS": "2" + }, + "BG4250@3": { + "A": "0", + "B": "BG4250", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171599.9, + 400198.7 + ], + "IO": "BG4250", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.17", + "SPS": "3" + }, + "BG4250@2": { + "A": "0", + "B": "BG4250", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171599.9, + 250198.7 + ], + "IO": "BG4250", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.17", + "SPS": "2" + }, + "BG4247@3": { + "A": "0", + "B": "BG4247", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 400198.5 + ], + "IO": "BG4247", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.16", + "SPS": "3" + }, + "BG4247@2": { + "A": "0", + "B": "BG4247", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 250198.5 + ], + "IO": "BG4247", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.16", + "SPS": "2" + }, + "BG4246@3": { + "A": "0", + "B": "BG4246", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173199.9, + 400198.7 + ], + "IO": "BG4246", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.15", + "SPS": "3" + }, + "BG4246@2": { + "A": "0", + "B": "BG4246", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173199.9, + 250198.7 + ], + "IO": "BG4246", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.15", + "SPS": "2" + }, + "BG4245@3": { + "A": "0", + "B": "BG4245", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173999.9, + 400198.7 + ], + "IO": "BG4245", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.14", + "SPS": "3" + }, + "BG4245@2": { + "A": "0", + "B": "BG4245", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173999.9, + 250198.7 + ], + "IO": "BG4245", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.14", + "SPS": "2" + }, + "BG4244@3": { + "A": "0", + "B": "BG4244", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 400198.5 + ], + "IO": "BG4244", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.13", + "SPS": "3" + }, + "BG4244@2": { + "A": "0", + "B": "BG4244", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 250198.5 + ], + "IO": "BG4244", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.13", + "SPS": "2" + }, + "BG4243@3": { + "A": "0", + "B": "BG4243", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.8, + 400198.7 + ], + "IO": "BG4243", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.12", + "SPS": "3" + }, + "BG4243@2": { + "A": "0", + "B": "BG4243", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.8, + 250198.7 + ], + "IO": "BG4243", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.12", + "SPS": "2" + }, + "BG4242@3": { + "A": "0", + "B": "BG4242", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.8, + 400198.7 + ], + "IO": "BG4242", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.11", + "SPS": "3" + }, + "BG4242@2": { + "A": "0", + "B": "BG4242", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.8, + 250198.7 + ], + "IO": "BG4242", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.11", + "SPS": "2" + }, + "BG4241@3": { + "A": "0", + "B": "BG4241", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 400198.5 + ], + "IO": "BG4241", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.10", + "SPS": "3" + }, + "BG4241@2": { + "A": "0", + "B": "BG4241", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 250198.5 + ], + "IO": "BG4241", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.10", + "SPS": "2" + }, + "BG4240@3": { + "A": "0", + "B": "BG4240", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.8, + 400198.7 + ], + "IO": "BG4240", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.09", + "SPS": "3" + }, + "BG4240@2": { + "A": "0", + "B": "BG4240", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.8, + 250198.7 + ], + "IO": "BG4240", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.09", + "SPS": "2" + }, + "BG4237@3": { + "A": "0", + "B": "BG4237", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.8, + 400198.7 + ], + "IO": "BG4237", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.08", + "SPS": "3" + }, + "BG4237@2": { + "A": "0", + "B": "BG4237", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.8, + 250198.7 + ], + "IO": "BG4237", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.08", + "SPS": "2" + }, + "BG4236@3": { + "A": "0", + "B": "BG4236", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 400198.8 + ], + "IO": "BG4236", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.07", + "SPS": "3" + }, + "BG4236@2": { + "A": "0", + "B": "BG4236", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 250198.8 + ], + "IO": "BG4236", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.07", + "SPS": "2" + }, + "BG4235@3": { + "A": "0", + "B": "BG4235", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.9, + 400199.1 + ], + "IO": "BG4235", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.06", + "SPS": "3" + }, + "BG4235@2": { + "A": "0", + "B": "BG4235", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.9, + 250199.1 + ], + "IO": "BG4235", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.06", + "SPS": "2" + }, + "BG4234@3": { + "A": "0", + "B": "BG4234", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.9, + 400199.1 + ], + "IO": "BG4234", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.05", + "SPS": "3" + }, + "BG4234@2": { + "A": "0", + "B": "BG4234", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.9, + 250199.1 + ], + "IO": "BG4234", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.05", + "SPS": "2" + }, + "BG4233@3": { + "A": "0", + "B": "BG4233", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 400198.8 + ], + "IO": "BG4233", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.04", + "SPS": "3" + }, + "BG4233@2": { + "A": "0", + "B": "BG4233", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 250198.8 + ], + "IO": "BG4233", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.04", + "SPS": "2" + }, + "BG4232@3": { + "A": "0", + "B": "BG4232", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184349.9, + 400199.1 + ], + "IO": "BG4232", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.03", + "SPS": "3" + }, + "BG4232@2": { + "A": "0", + "B": "BG4232", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184349.9, + 250199.1 + ], + "IO": "BG4232", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.03", + "SPS": "2" + }, + "BG4231@3": { + "A": "0", + "B": "BG4231", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 400199.1 + ], + "IO": "BG4231", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.02", + "SPS": "3" + }, + "BG4231@2": { + "A": "0", + "B": "BG4231", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 250199.1 + ], + "IO": "BG4231", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.02", + "SPS": "2" + }, + "BG4230@3": { + "A": "0", + "B": "BG4230", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185951.1, + 400199.1 + ], + "IO": "BG4230", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.1.01", + "SPS": "3" + }, + "BG4230@2": { + "A": "0", + "B": "BG4230", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185959.8, + 250440.3 + ], + "IO": "BG4230", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.1.01", + "SPS": "2" + }, + "BG4206@3": { + "A": "0", + "B": "BG4206", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187037.5, + 401606.0 + ], + "IO": "BG4206", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2305)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4206@2": { + "A": "0", + "B": "BG4206", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187037.5, + 251605.6 + ], + "IO": "BG4206", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 1305)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0263@3": { + "A": "0", + "B": "MA0263", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204234.8, + 401302.9 + ], + "IO": "MA0263", + "ID": "9999", + "VERW": "ILS-CV 2306", + "BEZEICHNUNG": "Motor MA0263 (CV-M2306)", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0263@2": { + "A": "0", + "B": "MA0263", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204231.7, + 251300.2 + ], + "IO": "MA0263", + "ID": "9999", + "VERW": "ILS-CV-M1306", + "BEZEICHNUNG": "Motor MA0263 (CV-M1306)", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4260@3": { + "A": "0", + "B": "BG4260", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204280.0, + 398835.2 + ], + "IO": "BG4260", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4260@2": { + "A": "0", + "B": "BG4260", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204280.0, + 248835.2 + ], + "IO": "BG4260", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4264@3": { + "A": "0", + "B": "BG4264", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204234.5, + 400417.1 + ], + "IO": "BG4264", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV 2306)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4264@2": { + "A": "0", + "B": "BG4264", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204234.5, + 250417.1 + ], + "IO": "BG4264", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1306)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4265@3": { + "A": "0", + "B": "BG4265", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204234.8, + 400991.5 + ], + "IO": "BG4265", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV 2306)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4265@2": { + "A": "0", + "B": "BG4265", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204234.8, + 250991.5 + ], + "IO": "BG4265", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (ILS-CV M1306)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4261@3": { + "A": "0", + "B": "BG4261", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203763.4, + 400128.2 + ], + "IO": "BG4261", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2303 ) Block 2.3.2", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4261@2": { + "A": "0", + "B": "BG4261", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203763.4, + 250128.2 + ], + "IO": "BG4261", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1303 ) Block 1.3.2", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4262@3": { + "A": "0", + "B": "BG4262", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203592.6, + 399808.7 + ], + "IO": "BG4262", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K2303 Einfahrt Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4262@2": { + "A": "0", + "B": "BG4262", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203592.6, + 249808.7 + ], + "IO": "BG4262", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1303 Einfahrt Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4266@3": { + "A": "0", + "B": "BG4266", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204234.8, + 401597.2 + ], + "IO": "BG4266", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2306)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4266@2": { + "A": "0", + "B": "BG4266", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204234.8, + 251593.2 + ], + "IO": "BG4266", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1306)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4296@3": { + "A": "0", + "B": "BG4296", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 400198.8 + ], + "IO": "BG4296", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.07", + "SPS": "3" + }, + "BG4296@2": { + "A": "0", + "B": "BG4296", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 250198.8 + ], + "IO": "BG4296", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.07", + "SPS": "2" + }, + "BG4295@3": { + "A": "0", + "B": "BG4295", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199149.9, + 400199.1 + ], + "IO": "BG4295", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.06", + "SPS": "3" + }, + "BG4295@2": { + "A": "0", + "B": "BG4295", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199149.9, + 250199.1 + ], + "IO": "BG4295", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.06", + "SPS": "2" + }, + "BG4294@3": { + "A": "0", + "B": "BG4294", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199949.9, + 400199.1 + ], + "IO": "BG4294", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.05", + "SPS": "3" + }, + "BG4294@2": { + "A": "0", + "B": "BG4294", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199949.9, + 250199.1 + ], + "IO": "BG4294", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.05", + "SPS": "2" + }, + "BG4293@3": { + "A": "0", + "B": "BG4293", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.0, + 400198.8 + ], + "IO": "BG4293", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.04", + "SPS": "3" + }, + "BG4293@2": { + "A": "0", + "B": "BG4293", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.0, + 250198.8 + ], + "IO": "BG4293", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.04", + "SPS": "2" + }, + "BG4292@3": { + "A": "0", + "B": "BG4292", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201549.9, + 400199.1 + ], + "IO": "BG4292", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.03", + "SPS": "3" + }, + "BG4292@2": { + "A": "0", + "B": "BG4292", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201549.9, + 250199.1 + ], + "IO": "BG4292", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.03", + "SPS": "2" + }, + "BG4291@3": { + "A": "0", + "B": "BG4291", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 400199.1 + ], + "IO": "BG4291", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.02", + "SPS": "3" + }, + "BG4291@2": { + "A": "0", + "B": "BG4291", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 250199.1 + ], + "IO": "BG4291", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.02", + "SPS": "2" + }, + "BG4290@3": { + "A": "0", + "B": "BG4290", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203159.8, + 400437.1 + ], + "IO": "BG4290", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.01", + "SPS": "3" + }, + "BG4290@2": { + "A": "0", + "B": "BG4290", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203159.8, + 250437.1 + ], + "IO": "BG4290", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.01", + "SPS": "2" + }, + "BG4304@3": { + "A": "0", + "B": "BG4304", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193149.9, + 400198.5 + ], + "IO": "BG4304", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.13", + "SPS": "3" + }, + "BG4304@2": { + "A": "0", + "B": "BG4304", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193149.9, + 250198.5 + ], + "IO": "BG4304", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.13", + "SPS": "2" + }, + "BG4303@3": { + "A": "0", + "B": "BG4303", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193949.8, + 400198.7 + ], + "IO": "BG4303", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.12", + "SPS": "3" + }, + "BG4303@2": { + "A": "0", + "B": "BG4303", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193949.8, + 250198.7 + ], + "IO": "BG4303", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.12", + "SPS": "2" + }, + "BG4302@3": { + "A": "0", + "B": "BG4302", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194749.8, + 400198.7 + ], + "IO": "BG4302", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.11", + "SPS": "3" + }, + "BG4302@2": { + "A": "0", + "B": "BG4302", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194749.8, + 250198.7 + ], + "IO": "BG4302", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.11", + "SPS": "2" + }, + "BG4301@3": { + "A": "0", + "B": "BG4301", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195549.9, + 400198.5 + ], + "IO": "BG4301", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.10", + "SPS": "3" + }, + "BG4301@2": { + "A": "0", + "B": "BG4301", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195549.9, + 250198.5 + ], + "IO": "BG4301", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.10", + "SPS": "2" + }, + "BG4300@3": { + "A": "0", + "B": "BG4300", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196349.8, + 400198.7 + ], + "IO": "BG4300", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.09", + "SPS": "3" + }, + "BG4300@2": { + "A": "0", + "B": "BG4300", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196349.8, + 250198.7 + ], + "IO": "BG4300", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.09", + "SPS": "2" + }, + "BG4297@3": { + "A": "0", + "B": "BG4297", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197149.8, + 400198.7 + ], + "IO": "BG4297", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.08", + "SPS": "3" + }, + "BG4297@2": { + "A": "0", + "B": "BG4297", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197149.8, + 250198.7 + ], + "IO": "BG4297", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.08", + "SPS": "2" + }, + "BG4310@3": { + "A": "0", + "B": "BG4310", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188899.9, + 400198.7 + ], + "IO": "BG4310", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.17", + "SPS": "3" + }, + "BG4310@2": { + "A": "0", + "B": "BG4310", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188899.9, + 250198.7 + ], + "IO": "BG4310", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.17", + "SPS": "2" + }, + "BG4307@3": { + "A": "0", + "B": "BG4307", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.0, + 400198.5 + ], + "IO": "BG4307", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.16", + "SPS": "3" + }, + "BG4307@2": { + "A": "0", + "B": "BG4307", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.0, + 250198.5 + ], + "IO": "BG4307", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.16", + "SPS": "2" + }, + "BG4306@3": { + "A": "0", + "B": "BG4306", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190499.9, + 400198.7 + ], + "IO": "BG4306", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.15", + "SPS": "3" + }, + "BG4306@2": { + "A": "0", + "B": "BG4306", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190499.9, + 250198.7 + ], + "IO": "BG4306", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.15", + "SPS": "2" + }, + "BG4305@3": { + "A": "0", + "B": "BG4305", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191299.9, + 400198.7 + ], + "IO": "BG4305", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.2.14", + "SPS": "3" + }, + "BG4305@2": { + "A": "0", + "B": "BG4305", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191299.9, + 250198.7 + ], + "IO": "BG4305", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.2.14", + "SPS": "2" + }, + "BG4267@3": { + "A": "0", + "B": "BG4267", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200391.4, + 398859.2 + ], + "IO": "BG4267", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K2303 Einfahrt Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4267@2": { + "A": "0", + "B": "BG4267", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200391.4, + 248859.2 + ], + "IO": "BG4267", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1303 Einfahrt Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4270@3": { + "A": "0", + "B": "BG4270", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196799.9, + 398853.8 + ], + "IO": "BG4270", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2303 Einfahrt Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4270@2": { + "A": "0", + "B": "BG4270", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196799.9, + 248853.8 + ], + "IO": "BG4270", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1303 Einfahrt Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4271@3": { + "A": "0", + "B": "BG4271", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193587.3, + 398853.8 + ], + "IO": "BG4271", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K2303 Einfahrt Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4271@2": { + "A": "0", + "B": "BG4271", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193587.3, + 248853.8 + ], + "IO": "BG4271", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1303 Einfahrt Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4272@3": { + "A": "0", + "B": "BG4272", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189413.6, + 398853.8 + ], + "IO": "BG4272", + "ID": "", + "VERW": "Sync P5", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K2303 Einfahrt Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4272@2": { + "A": "0", + "B": "BG4272", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189413.6, + 248853.8 + ], + "IO": "BG4272", + "ID": "", + "VERW": "Sync P5", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K1303 Einfahrt Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0261@3": { + "A": "0", + "B": "MA0261", + "C": "20261710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205767.6, + 398389.3 + ], + "IO": "MA0261", + "ID": "9999", + "VERW": "ILS- KR M2304)", + "BEZEICHNUNG": "Motor MA0261 (KR-M2304)", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0261@2": { + "A": "0", + "B": "MA0261", + "C": "20261710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205697.7, + 247871.8 + ], + "IO": "MA0261", + "ID": "9999", + "VERW": "ILS-KR M1304", + "BEZEICHNUNG": "Motor MA0261 (KR-M1304)", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0264@3": { + "A": "0", + "B": "MA0264", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206399.7, + 401314.0 + ], + "IO": "MA0264", + "ID": "9999", + "VERW": "CV 0,552307", + "BEZEICHNUNG": "Motor MA0264 (ILS-CV 2307)", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0264@2": { + "A": "0", + "B": "MA0264", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206396.6, + 251311.3 + ], + "IO": "MA0264", + "ID": "9999", + "VERW": "ILS-CV M1307", + "BEZEICHNUNG": "Motor MA0264 (ILS-CV M1307)", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4324@3": { + "A": "0", + "B": "BG4324", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206399.4, + 400428.3 + ], + "IO": "BG4324", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV 2307)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4324@2": { + "A": "0", + "B": "BG4324", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206399.4, + 250428.3 + ], + "IO": "BG4324", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1307)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4325@3": { + "A": "0", + "B": "BG4325", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206399.7, + 401002.7 + ], + "IO": "BG4325", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (KR-K2307 vor BT-Beladung)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4325@2": { + "A": "0", + "B": "BG4325", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206399.7, + 251002.7 + ], + "IO": "BG4325", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (ILS-CV M1307)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4326@3": { + "A": "0", + "B": "BG4326", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206399.7, + 401629.7 + ], + "IO": "BG4326", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2307)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4326@2": { + "A": "0", + "B": "BG4326", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206399.7, + 251604.3 + ], + "IO": "BG4326", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 1307)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4323@3": { + "A": "0", + "B": "BG4323", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206399.7, + 399948.7 + ], + "IO": "BG4323", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2304)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4323@2": { + "A": "0", + "B": "BG4323", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206399.7, + 249948.7 + ], + "IO": "BG4323", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M1304)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4322@3": { + "A": "0", + "B": "BG4322", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207454.4, + 399808.7 + ], + "IO": "BG4322", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K2304 Einfahrt Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4322@2": { + "A": "0", + "B": "BG4322", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207454.4, + 249808.7 + ], + "IO": "BG4322", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1304 Einfahrt Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4321@3": { + "A": "0", + "B": "BG4321", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207172.5, + 400128.3 + ], + "IO": "BG4321", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2304) Block 2.3.3", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4321@2": { + "A": "0", + "B": "BG4321", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207172.5, + 250128.3 + ], + "IO": "BG4321", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1304) Block 1.3.3", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4320@3": { + "A": "0", + "B": "BG4320", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207436.2, + 398763.1 + ], + "IO": "BG4320", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4320@2": { + "A": "0", + "B": "BG4320", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207440.6, + 248833.6 + ], + "IO": "BG4320", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4337@3": { + "A": "0", + "B": "BG4337", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206958.8, + 398144.5 + ], + "IO": "BG4337", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4337@2": { + "A": "0", + "B": "BG4337", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207511.0, + 248141.3 + ], + "IO": "BG4337", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4350@3": { + "A": "0", + "B": "BG4350", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208400.0, + 400204.6 + ], + "IO": "BG4350", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.01", + "SPS": "3" + }, + "BG4350@2": { + "A": "0", + "B": "BG4350", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208400.0, + 250204.6 + ], + "IO": "BG4350", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.01", + "SPS": "2" + }, + "BG4351@3": { + "A": "0", + "B": "BG4351", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209200.0, + 400204.6 + ], + "IO": "BG4351", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.02", + "SPS": "3" + }, + "BG4351@2": { + "A": "0", + "B": "BG4351", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209200.0, + 250204.6 + ], + "IO": "BG4351", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.02", + "SPS": "2" + }, + "BG4352@3": { + "A": "0", + "B": "BG4352", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210000.0, + 400204.6 + ], + "IO": "BG4352", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.03", + "SPS": "3" + }, + "BG4352@2": { + "A": "0", + "B": "BG4352", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210000.0, + 250204.6 + ], + "IO": "BG4352", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.03", + "SPS": "2" + }, + "BG4353@3": { + "A": "0", + "B": "BG4353", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211146.1, + 400204.5 + ], + "IO": "BG4353", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.04", + "SPS": "3" + }, + "BG4353@2": { + "A": "0", + "B": "BG4353", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211146.1, + 250204.5 + ], + "IO": "BG4353", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.04", + "SPS": "2" + }, + "BG4354@3": { + "A": "0", + "B": "BG4354", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211946.1, + 400204.5 + ], + "IO": "BG4354", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.05", + "SPS": "3" + }, + "BG4354@2": { + "A": "0", + "B": "BG4354", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211946.1, + 250204.5 + ], + "IO": "BG4354", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.05", + "SPS": "2" + }, + "BG4355@3": { + "A": "0", + "B": "BG4355", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212746.1, + 400204.6 + ], + "IO": "BG4355", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.06", + "SPS": "3" + }, + "BG4355@2": { + "A": "0", + "B": "BG4355", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212746.1, + 250204.6 + ], + "IO": "BG4355", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.06", + "SPS": "2" + }, + "BG4356@3": { + "A": "0", + "B": "BG4356", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213545.3, + 400204.5 + ], + "IO": "BG4356", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.07", + "SPS": "3" + }, + "BG4356@2": { + "A": "0", + "B": "BG4356", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213545.3, + 250204.5 + ], + "IO": "BG4356", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.07", + "SPS": "2" + }, + "BG4357@3": { + "A": "0", + "B": "BG4357", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214346.1, + 400204.5 + ], + "IO": "BG4357", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.08", + "SPS": "3" + }, + "BG4357@2": { + "A": "0", + "B": "BG4357", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214346.1, + 250204.5 + ], + "IO": "BG4357", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.08", + "SPS": "2" + }, + "BG4360@3": { + "A": "0", + "B": "BG4360", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215146.1, + 400205.3 + ], + "IO": "BG4360", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.09", + "SPS": "3" + }, + "BG4360@2": { + "A": "0", + "B": "BG4360", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215146.1, + 250205.3 + ], + "IO": "BG4360", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.09", + "SPS": "2" + }, + "BG4361@3": { + "A": "0", + "B": "BG4361", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217150.0, + 400204.3 + ], + "IO": "BG4361", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.10", + "SPS": "3" + }, + "BG4361@2": { + "A": "0", + "B": "BG4361", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217150.0, + 250204.3 + ], + "IO": "BG4361", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.10", + "SPS": "2" + }, + "BG4362@3": { + "A": "0", + "B": "BG4362", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217950.0, + 400204.3 + ], + "IO": "BG4362", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.11", + "SPS": "3" + }, + "BG4362@2": { + "A": "0", + "B": "BG4362", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217950.0, + 250204.3 + ], + "IO": "BG4362", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.11", + "SPS": "2" + }, + "BG4363@3": { + "A": "0", + "B": "BG4363", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218750.0, + 400204.3 + ], + "IO": "BG4363", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.12", + "SPS": "3" + }, + "BG4363@2": { + "A": "0", + "B": "BG4363", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218750.0, + 250204.3 + ], + "IO": "BG4363", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.12", + "SPS": "2" + }, + "BG4364@3": { + "A": "0", + "B": "BG4364", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219549.1, + 400204.3 + ], + "IO": "BG4364", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.13", + "SPS": "3" + }, + "BG4364@2": { + "A": "0", + "B": "BG4364", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219549.1, + 250204.3 + ], + "IO": "BG4364", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.13", + "SPS": "2" + }, + "BG4365@3": { + "A": "0", + "B": "BG4365", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220350.0, + 400204.3 + ], + "IO": "BG4365", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.14", + "SPS": "3" + }, + "BG4365@2": { + "A": "0", + "B": "BG4365", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220350.0, + 250204.3 + ], + "IO": "BG4365", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.14", + "SPS": "2" + }, + "BG4366@3": { + "A": "0", + "B": "BG4366", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221150.0, + 400204.3 + ], + "IO": "BG4366", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.15", + "SPS": "3" + }, + "BG4366@2": { + "A": "0", + "B": "BG4366", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221150.0, + 250204.3 + ], + "IO": "BG4366", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.15", + "SPS": "2" + }, + "BG4367@3": { + "A": "0", + "B": "BG4367", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221950.0, + 400204.3 + ], + "IO": "BG4367", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.16", + "SPS": "3" + }, + "BG4367@2": { + "A": "0", + "B": "BG4367", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221950.0, + 250204.3 + ], + "IO": "BG4367", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.16", + "SPS": "2" + }, + "BG4370@3": { + "A": "0", + "B": "BG4370", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223150.0, + 400204.3 + ], + "IO": "BG4370", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.17", + "SPS": "3" + }, + "BG4370@2": { + "A": "0", + "B": "BG4370", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223150.0, + 250204.3 + ], + "IO": "BG4370", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.17", + "SPS": "2" + }, + "BG4371@3": { + "A": "0", + "B": "BG4371", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223950.0, + 400204.3 + ], + "IO": "BG4371", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.18 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.18", + "SPS": "3" + }, + "BG4371@2": { + "A": "0", + "B": "BG4371", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223950.0, + 250204.3 + ], + "IO": "BG4371", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.18 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.18", + "SPS": "2" + }, + "BG4372@3": { + "A": "0", + "B": "BG4372", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224748.4, + 400204.3 + ], + "IO": "BG4372", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.19 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.19", + "SPS": "3" + }, + "BG4372@2": { + "A": "0", + "B": "BG4372", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224748.4, + 250204.3 + ], + "IO": "BG4372", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.19 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.19", + "SPS": "2" + }, + "BG4374@3": { + "A": "0", + "B": "BG4374", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226292.5, + 400204.3 + ], + "IO": "BG4374", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.21 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.21", + "SPS": "3" + }, + "BG4374@2": { + "A": "0", + "B": "BG4374", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226292.5, + 250204.3 + ], + "IO": "BG4374", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.21 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.21", + "SPS": "2" + }, + "BG4373@3": { + "A": "0", + "B": "BG4373", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225550.0, + 400204.3 + ], + "IO": "BG4373", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.20 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.3.20", + "SPS": "3" + }, + "BG4373@2": { + "A": "0", + "B": "BG4373", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225550.0, + 250204.3 + ], + "IO": "BG4373", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.20 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.3.20", + "SPS": "2" + }, + "BG4332@3": { + "A": "0", + "B": "BG4332", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221675.6, + 398849.9 + ], + "IO": "BG4332", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K2304 Einfahrt Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4332@2": { + "A": "0", + "B": "BG4332", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221675.6, + 248849.9 + ], + "IO": "BG4332", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K1304 Einfahrt Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4331@3": { + "A": "0", + "B": "BG4331", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218467.0, + 398849.9 + ], + "IO": "BG4331", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K2304 Einfahrt Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4331@2": { + "A": "0", + "B": "BG4331", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218467.0, + 248849.9 + ], + "IO": "BG4331", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1304 Einfahrt Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4330@3": { + "A": "0", + "B": "BG4330", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214467.8, + 398847.2 + ], + "IO": "BG4330", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2304 Einfahrt Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4330@2": { + "A": "0", + "B": "BG4330", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214467.8, + 248847.2 + ], + "IO": "BG4330", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1304 Einfahrt Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4327@3": { + "A": "0", + "B": "BG4327", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211112.4, + 398849.9 + ], + "IO": "BG4327", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K2304 Einfahrt Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4327@2": { + "A": "0", + "B": "BG4327", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211112.4, + 248849.9 + ], + "IO": "BG4327", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1304 Einfahrt Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4335@3": { + "A": "0", + "B": "BG4335", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224320.9, + 398247.3 + ], + "IO": "BG4335", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 1 (M2309)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4335@2": { + "A": "0", + "B": "BG4335", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216340.5, + 247182.6 + ], + "IO": "BG4335", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (M1309)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4334@3": { + "A": "0", + "B": "BG4334", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226182.6, + 397653.7 + ], + "IO": "BG4334", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4334@2": { + "A": "0", + "B": "BG4334", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214566.0, + 247170.1 + ], + "IO": "BG4334", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV-M1309)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4333@3": { + "A": "0", + "B": "BG4333", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225264.8, + 398869.6 + ], + "IO": "BG4333", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.6 (KR-K2304 Einfahrt Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4333@2": { + "A": "0", + "B": "BG4333", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225264.8, + 248869.6 + ], + "IO": "BG4333", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.6 (KR-K1304 Einfahrt Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0265@3": { + "A": "0", + "B": "MA0265", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227556.2, + 401314.0 + ], + "IO": "MA0265", + "ID": "9999", + "VERW": "CV 0,55M2308", + "BEZEICHNUNG": "Motor MA0265 (CV-M2308)", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0265@2": { + "A": "0", + "B": "MA0265", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227401.6, + 251308.7 + ], + "IO": "MA0265", + "ID": "9999", + "VERW": "ILS-CV M1308", + "BEZEICHNUNG": "Motor MA0265 (ILS-CV M1308)", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4384@3": { + "A": "0", + "B": "BG4384", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227555.6, + 400428.3 + ], + "IO": "BG4384", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M2308)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4384@2": { + "A": "0", + "B": "BG4384", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227404.1, + 250425.6 + ], + "IO": "BG4384", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1308)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4385@3": { + "A": "0", + "B": "BG4385", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227555.9, + 401002.7 + ], + "IO": "BG4385", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M2308)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4385@2": { + "A": "0", + "B": "BG4385", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227404.4, + 251000.0 + ], + "IO": "BG4385", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (ILS-CV M1308)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4386@3": { + "A": "0", + "B": "BG4386", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227558.6, + 401614.7 + ], + "IO": "BG4386", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2308)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4386@2": { + "A": "0", + "B": "BG4386", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227404.6, + 251604.1 + ], + "IO": "BG4386", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1308)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4383@3": { + "A": "0", + "B": "BG4383", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227343.2, + 400128.5 + ], + "IO": "BG4383", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2304)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4383@2": { + "A": "0", + "B": "BG4383", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227404.4, + 250128.5 + ], + "IO": "BG4383", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M1304)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4382@3": { + "A": "0", + "B": "BG4382", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228296.5, + 399808.7 + ], + "IO": "BG4382", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K2304 Einfahrt Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4382@2": { + "A": "0", + "B": "BG4382", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228296.5, + 249808.7 + ], + "IO": "BG4382", + "ID": "", + "VERW": "Sync P1", + "BEZEICHNUNG": "Prüfung MT Pos.1 (KR-K1304 Einfahrt Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4381@3": { + "A": "0", + "B": "BG4381", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228109.8, + 400128.3 + ], + "IO": "BG4381", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M2304) Block 2.3.4", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4381@2": { + "A": "0", + "B": "BG4381", + "C": "20073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228171.0, + 250128.3 + ], + "IO": "BG4381", + "ID": "", + "VERW": "PIN query", + "BEZEICHNUNG": "Pin Abfrage (KR-M1304) Block 1.3.4", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4380@3": { + "A": "0", + "B": "BG4380", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227459.1, + 398874.9 + ], + "IO": "BG4380", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4380@2": { + "A": "0", + "B": "BG4380", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227459.1, + 248874.9 + ], + "IO": "BG4380", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4410@3": { + "A": "0", + "B": "BG4410", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 400204.6 + ], + "IO": "BG4410", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.01", + "SPS": "3" + }, + "BG4410@2": { + "A": "0", + "B": "BG4410", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 250204.6 + ], + "IO": "BG4410", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.1 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.01", + "SPS": "2" + }, + "BG4411@3": { + "A": "0", + "B": "BG4411", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 400204.6 + ], + "IO": "BG4411", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.02", + "SPS": "3" + }, + "BG4411@2": { + "A": "0", + "B": "BG4411", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 250204.6 + ], + "IO": "BG4411", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.2 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.02", + "SPS": "2" + }, + "BG4412@3": { + "A": "0", + "B": "BG4412", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 400204.6 + ], + "IO": "BG4412", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.03", + "SPS": "3" + }, + "BG4412@2": { + "A": "0", + "B": "BG4412", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 250204.6 + ], + "IO": "BG4412", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.3 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.03", + "SPS": "2" + }, + "BG4413@3": { + "A": "0", + "B": "BG4413", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 400201.3 + ], + "IO": "BG4413", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.04", + "SPS": "3" + }, + "BG4413@2": { + "A": "0", + "B": "BG4413", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 250201.3 + ], + "IO": "BG4413", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.4 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.04", + "SPS": "2" + }, + "BG4414@3": { + "A": "0", + "B": "BG4414", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 400201.3 + ], + "IO": "BG4414", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.05", + "SPS": "3" + }, + "BG4414@2": { + "A": "0", + "B": "BG4414", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 250201.3 + ], + "IO": "BG4414", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.5 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.05", + "SPS": "2" + }, + "BG4415@3": { + "A": "0", + "B": "BG4415", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 400201.4 + ], + "IO": "BG4415", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.06", + "SPS": "3" + }, + "BG4415@2": { + "A": "0", + "B": "BG4415", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 250201.4 + ], + "IO": "BG4415", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.6 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.06", + "SPS": "2" + }, + "BG4416@3": { + "A": "0", + "B": "BG4416", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233949.1, + 400201.3 + ], + "IO": "BG4416", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.07", + "SPS": "3" + }, + "BG4416@2": { + "A": "0", + "B": "BG4416", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233949.1, + 250201.3 + ], + "IO": "BG4416", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.7 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.07", + "SPS": "2" + }, + "BG4417@3": { + "A": "0", + "B": "BG4417", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 400201.3 + ], + "IO": "BG4417", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.08", + "SPS": "3" + }, + "BG4417@2": { + "A": "0", + "B": "BG4417", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 250201.3 + ], + "IO": "BG4417", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.8 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.08", + "SPS": "2" + }, + "BG4420@3": { + "A": "0", + "B": "BG4420", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 400202.1 + ], + "IO": "BG4420", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.09", + "SPS": "3" + }, + "BG4420@2": { + "A": "0", + "B": "BG4420", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 250202.1 + ], + "IO": "BG4420", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.9 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.09", + "SPS": "2" + }, + "BG4390@3": { + "A": "0", + "B": "BG4390", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235175.7, + 398845.0 + ], + "IO": "BG4390", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K2304 Einfahrt Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4390@2": { + "A": "0", + "B": "BG4390", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235309.9, + 248847.2 + ], + "IO": "BG4390", + "ID": "", + "VERW": "Sync P3", + "BEZEICHNUNG": "Prüfung MT Pos.3 (KR-K1304 Einfahrt Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4387@3": { + "A": "0", + "B": "BG4387", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231954.5, + 398849.9 + ], + "IO": "BG4387", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K2304 Einfahrt Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4387@2": { + "A": "0", + "B": "BG4387", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231954.5, + 248849.9 + ], + "IO": "BG4387", + "ID": "", + "VERW": "Sync P2", + "BEZEICHNUNG": "Prüfung MT Pos.2 (KR-K1304 Einfahrt Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4421@3": { + "A": "0", + "B": "BG4421", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 400204.3 + ], + "IO": "BG4421", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.10", + "SPS": "3" + }, + "BG4421@2": { + "A": "0", + "B": "BG4421", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 250204.3 + ], + "IO": "BG4421", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.10 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.10", + "SPS": "2" + }, + "BG4422@3": { + "A": "0", + "B": "BG4422", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 400204.3 + ], + "IO": "BG4422", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.11", + "SPS": "3" + }, + "BG4422@2": { + "A": "0", + "B": "BG4422", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 250204.3 + ], + "IO": "BG4422", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.11 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.11", + "SPS": "2" + }, + "BG4423@3": { + "A": "0", + "B": "BG4423", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 400204.3 + ], + "IO": "BG4423", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.12", + "SPS": "3" + }, + "BG4423@2": { + "A": "0", + "B": "BG4423", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 250204.3 + ], + "IO": "BG4423", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.12 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.12", + "SPS": "2" + }, + "BG4424@3": { + "A": "0", + "B": "BG4424", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239149.1, + 400204.3 + ], + "IO": "BG4424", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.13", + "SPS": "3" + }, + "BG4424@2": { + "A": "0", + "B": "BG4424", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239149.1, + 250204.3 + ], + "IO": "BG4424", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.13 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.3.4.13", + "SPS": "2" + }, + "BG4391@3": { + "A": "0", + "B": "BG4391", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238336.8, + 398849.9 + ], + "IO": "BG4391", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K2304 Einfahrt Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4391@2": { + "A": "0", + "B": "BG4391", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238336.8, + 248849.9 + ], + "IO": "BG4391", + "ID": "", + "VERW": "Sync P4", + "BEZEICHNUNG": "Prüfung MT Pos.4 (KR-K1304 Einfahrt Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3192@3": { + "A": "0", + "B": "BG3192", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241338.5, + 457904.2 + ], + "IO": "BG3192", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (KR-M2102 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3192@2": { + "A": "0", + "B": "BG3192", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238641.0, + 309590.8 + ], + "IO": "BG3192", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (KR-M1102)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4444@3": { + "A": "0", + "B": "BG4444", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242270.9, + 457166.7 + ], + "IO": "BG4444", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (KR-K2110)", + "KENNZEICHNUNG": "=A01+UC0309-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4444@2": { + "A": "0", + "B": "BG4444", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241877.4, + 301022.7 + ], + "IO": "BG4444", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M0520)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3193@3": { + "A": "0", + "B": "BG3193", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239381.8, + 458837.5 + ], + "IO": "BG3193", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2102 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3144@2": { + "A": "0", + "B": "BG3144", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221695.4, + 460906.6 + ], + "IO": "BG3144", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1109)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3143@2": { + "A": "0", + "B": "BG3143", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222435.2, + 460903.2 + ], + "IO": "BG3143", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M1109) ", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3145@2": { + "A": "0", + "B": "BG3145", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220950.2, + 460903.2 + ], + "IO": "BG3145", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1109) ", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3623@2": { + "A": "0", + "B": "BG3623", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222672.8, + 439406.3 + ], + "IO": "BG3623", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1209)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3622@2": { + "A": "0", + "B": "BG3622", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223412.7, + 439132.9 + ], + "IO": "BG3622", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M1209)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3624@2": { + "A": "0", + "B": "BG3624", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221927.7, + 439402.9 + ], + "IO": "BG3624", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1209)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3615@3": { + "A": "0", + "B": "BG3615", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "2", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226572.6, + 439215.3 + ], + "IO": "BG3615", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M1209)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3615@2": { + "A": "0", + "B": "BG3615", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215007.9, + 289194.1 + ], + "IO": "BG3615", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (M1209)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3614@3": { + "A": "0", + "B": "BG3614", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227453.2, + 439228.0 + ], + "IO": "BG3614", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3614@2": { + "A": "0", + "B": "BG3614", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214544.0, + 288491.5 + ], + "IO": "BG3614", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3616@3": { + "A": "0", + "B": "BG3616", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225996.0, + 438549.8 + ], + "IO": "BG3616", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2202)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3616@2": { + "A": "0", + "B": "BG3616", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217070.7, + 289486.8 + ], + "IO": "BG3616", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1209)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3431@3": { + "A": "0", + "B": "BG3431", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240232.5, + 440258.2 + ], + "IO": "BG3431", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (ILS-CV M2104 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3431@2": { + "A": "0", + "B": "BG3431", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228521.8, + 290102.3 + ], + "IO": "BG3431", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 1 (M2109)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3431@5": { + "A": "0", + "B": "BG3431", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236619.8, + 151954.5 + ], + "IO": "BG3431", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-KR M0500)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3431@4": { + "A": "0", + "B": "BG3431", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355162.2, + 751437.5 + ], + "IO": "BG3431", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (AMR ILS-CV M4009)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3432@3": { + "A": "0", + "B": "BG3432", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237421.5, + 440384.1 + ], + "IO": "BG3432", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M2109 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3432@5": { + "A": "0", + "B": "BG3432", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236300.3, + 150578.0 + ], + "IO": "BG3432", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator(ILS-KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MA0070@3": { + "A": "0", + "B": "MA0070", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237452.4, + 439519.3 + ], + "IO": "MA0070", + "ID": "9999", + "VERW": "CV 0,55M2109", + "BEZEICHNUNG": "Motor MA0070 (CV-M2109)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ9", + "TEXT-D": "Motor MA0070", + "TEXT-E": "Motor MA0070", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0070@2": { + "A": "0", + "B": "MA0070", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216325.0, + 289484.1 + ], + "IO": "MA0070", + "ID": "9999", + "VERW": "ILS-CV M1209", + "BEZEICHNUNG": "Motor MA0070 (CV-M1209)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ8", + "TEXT-D": "Motor MA0070", + "TEXT-E": "Motor MA0070", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0070@1": { + "A": "0", + "B": "MA0070", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370718.9, + 181184.1 + ], + "IO": "MA0070", + "ID": "9999", + "VERW": "M0070 0,18", + "BEZEICHNUNG": "Motor 1 MA0070 Einfahren LS 1", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor 1 MA0070 Einfahren LS 1", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0070@5": { + "A": "0", + "B": "MA0070", + "C": "10070710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1 - HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236615.2, + 153034.5 + ], + "IO": "MA0070", + "ID": "9999", + "VERW": "ILS-CV M5008", + "BEZEICHNUNG": "Motor MA0070 (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "Motor MA0070", + "TEXT-E": "Motor MA0070", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MA0070@4": { + "A": "0", + "B": "MA0070", + "C": "10073710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 378156.0, + 751751.3 + ], + "IO": "MA0070", + "ID": "9999", + "VERW": "ILS-CV-M4000", + "BEZEICHNUNG": "Motor MA0070 (ILS-CV-M4000)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3434@3": { + "A": "0", + "B": "BG3434", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238268.1, + 439519.3 + ], + "IO": "BG3434", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 1 (M2109)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3434@5": { + "A": "0", + "B": "BG3434", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239000.3, + 150368.2 + ], + "IO": "BG3434", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS-KR M5002)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3434@4": { + "A": "0", + "B": "BG3434", + "C": "10073710081010151939", + "ARTINR": "829434314", + "BESCHR": "PIN DETECTION LEFT MECHANIC CPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355956.0, + 752585.6 + ], + "IO": "BG3434", + "ID": "", + "VERW": "GOH check", + "BEZEICHNUNG": "Behangskontrolle an Separator(AMR KR-M4003)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3433@3": { + "A": "0", + "B": "BG3433", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236565.8, + 440396.1 + ], + "IO": "BG3433", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2109)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3433@2": { + "A": "0", + "B": "BG3433", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238482.8, + 291491.5 + ], + "IO": "BG3433", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M1104)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3433@5": { + "A": "0", + "B": "BG3433", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238172.1, + 152032.3 + ], + "IO": "BG3433", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator(ILS-KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3433@4": { + "A": "0", + "B": "BG3433", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358239.6, + 752867.2 + ], + "IO": "BG3433", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3435@3": { + "A": "0", + "B": "BG3435", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239350.7, + 440258.2 + ], + "IO": "BG3435", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (KR-M2109)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3435@4": { + "A": "0", + "B": "BG3435", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355960.7, + 752861.8 + ], + "IO": "BG3435", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (AMR KR-M4003)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3435@5": { + "A": "0", + "B": "BG3435", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239738.2, + 150372.6 + ], + "IO": "BG3435", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (ILS-CV KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3672@3": { + "A": "0", + "B": "BG3672", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241308.0, + 436806.6 + ], + "IO": "BG3672", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3672@2": { + "A": "0", + "B": "BG3672", + "C": "20073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238641.3, + 288583.7 + ], + "IO": "BG3672", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (KR-M1202)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4091@3": { + "A": "0", + "B": "BG4091", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226101.9, + 419498.6 + ], + "IO": "BG4091", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV 2309)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4091@2": { + "A": "0", + "B": "BG4091", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216481.1, + 267740.4 + ], + "IO": "BG4091", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS-KR-M1302)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0204@3": { + "A": "0", + "B": "MA0204", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224954.4, + 419498.6 + ], + "IO": "MA0204", + "ID": "9999", + "VERW": "ILS-CV-M2309", + "BEZEICHNUNG": "Motor MA0204 (CV-M2309)", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0205@3": { + "A": "0", + "B": "MA0205", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237782.7, + 419842.9 + ], + "IO": "MA0205", + "ID": "9999", + "VERW": "ILS-CV M2209", + "BEZEICHNUNG": "Motor MA0205 (CV-M2209)", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3913@3": { + "A": "0", + "B": "BG3913", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237343.6, + 420830.6 + ], + "IO": "BG3913", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2209)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3912@3": { + "A": "0", + "B": "BG3912", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238124.1, + 420818.5 + ], + "IO": "BG3912", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 5 (ILS-CV M2209)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3912@2": { + "A": "0", + "B": "BG3912", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239527.4, + 272532.2 + ], + "IO": "BG3912", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M1204)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3910@3": { + "A": "0", + "B": "BG3910", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240407.6, + 420737.9 + ], + "IO": "BG3910", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3910@2": { + "A": "0", + "B": "BG3910", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229108.5, + 270970.0 + ], + "IO": "BG3910", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 2 (M2209)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4145@3": { + "A": "0", + "B": "BG4145", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240382.0, + 417552.1 + ], + "IO": "BG4145", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4185@3": { + "A": "0", + "B": "BG4185", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241151.5, + 416053.7 + ], + "IO": "BG4185", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.14", + "SPS": "3" + }, + "BG4186@3": { + "A": "0", + "B": "BG4186", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241951.5, + 416053.7 + ], + "IO": "BG4186", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.15", + "SPS": "3" + }, + "BG4152@3": { + "A": "0", + "B": "BG4152", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241436.8, + 418878.7 + ], + "IO": "BG4152", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2302 Block 2.3.4) ", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4343@2": { + "A": "0", + "B": "BG4343", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223499.9, + 397074.5 + ], + "IO": "BG4343", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1309) ", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4342@2": { + "A": "0", + "B": "BG4342", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224215.4, + 397074.7 + ], + "IO": "BG4342", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M1309) ", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4344@2": { + "A": "0", + "B": "BG4344", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222730.4, + 397074.7 + ], + "IO": "BG4344", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1309) ", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4425@3": { + "A": "0", + "B": "BG4425", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241149.1, + 400204.3 + ], + "IO": "BG4425", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.14", + "SPS": "3" + }, + "BG4426@3": { + "A": "0", + "B": "BG4426", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241949.1, + 400204.3 + ], + "IO": "BG4426", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "2.3.4.15", + "SPS": "3" + }, + "BG4392@3": { + "A": "0", + "B": "BG4392", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241444.5, + 398378.8 + ], + "IO": "BG4392", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 3 (M2302)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4092@3": { + "A": "0", + "B": "BG4092", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227926.5, + 418493.7 + ], + "IO": "BG4092", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS-CV 2309)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4093@3": { + "A": "0", + "B": "BG4093", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224329.3, + 418582.0 + ], + "IO": "BG4093", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2309)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4094@3": { + "A": "0", + "B": "BG4094", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226186.5, + 417799.0 + ], + "IO": "BG4094", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 3 (M2302)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0071@3": { + "A": "0", + "B": "MA0071", + "C": "20071710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243311.1, + 459570.8 + ], + "IO": "MA0071", + "ID": "9999", + "VERW": "ILS-KR M2110", + "BEZEICHNUNG": "Motor MA0071 (KR-M2110)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ9", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0071@2": { + "A": "0", + "B": "MA0071", + "C": "20071710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241227.9, + 296774.6 + ], + "IO": "MA0071", + "ID": "9999", + "VERW": "ILS-CV M1401", + "BEZEICHNUNG": "Motor MA0071 (CV-M1401)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ8", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0071@4": { + "A": "0", + "B": "MA0071", + "C": "10073710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 362109.7, + 752445.4 + ], + "IO": "MA0071", + "ID": "9999", + "VERW": "ILS-CV-M4001", + "BEZEICHNUNG": "Motor MA0071 (ILS-CV-M4001)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MA0073@3": { + "A": "0", + "B": "MA0073", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 246031.6, + 458949.5 + ], + "IO": "MA0073", + "ID": "9999", + "VERW": "CV 0,55 M2111", + "BEZEICHNUNG": "Motor MA0073 (CV-M2111)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ9", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0073@2": { + "A": "0", + "B": "MA0073", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242987.8, + 277941.7 + ], + "IO": "MA0073", + "ID": "9999", + "VERW": "ILS-CV M1601", + "BEZEICHNUNG": "Motor MA0073 (CV-M1601)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ8", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0073@4": { + "A": "0", + "B": "MA0073", + "C": "10073710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358151.1, + 742499.7 + ], + "IO": "MA0073", + "ID": "9999", + "VERW": "CV-M4002_0,75", + "BEZEICHNUNG": "Motor MA0073 (ILS-CV-M4002)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG4440@3": { + "A": "0", + "B": "BG4440", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244310.6, + 457678.9 + ], + "IO": "BG4440", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV 2111)", + "KENNZEICHNUNG": "=A01+UC0309-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4440@2": { + "A": "0", + "B": "BG4440", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242124.4, + 299526.8 + ], + "IO": "BG4440", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (KR-M1100)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4441@3": { + "A": "0", + "B": "BG4441", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 245289.1, + 458961.4 + ], + "IO": "BG4441", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV 2111) ", + "KENNZEICHNUNG": "=A01+UC0309-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4442@3": { + "A": "0", + "B": "BG4442", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 246774.1, + 458961.2 + ], + "IO": "BG4442", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 2111)", + "KENNZEICHNUNG": "=A01+UC0309-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4442@2": { + "A": "0", + "B": "BG4442", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242116.8, + 300434.5 + ], + "IO": "BG4442", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS-KR M1100) ", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4443@2": { + "A": "0", + "B": "BG4443", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242124.4, + 299238.0 + ], + "IO": "BG4443", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 7 (ILS-KR M1100) ", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4460@2": { + "A": "0", + "B": "BG4460", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241057.8, + 442762.3 + ], + "IO": "BG4460", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1401) ", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4541@2": { + "A": "0", + "B": "BG4541", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240356.2, + 424341.8 + ], + "IO": "BG4541", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1501)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4540@2": { + "A": "0", + "B": "BG4540", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240343.6, + 423437.5 + ], + "IO": "BG4540", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1401) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4542@2": { + "A": "0", + "B": "BG4542", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240353.5, + 424608.4 + ], + "IO": "BG4542", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1501) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4544@2": { + "A": "0", + "B": "BG4544", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242674.9, + 420778.8 + ], + "IO": "BG4544", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M1601)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4543@2": { + "A": "0", + "B": "BG4543", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242660.5, + 419880.2 + ], + "IO": "BG4543", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M1401) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4545@2": { + "A": "0", + "B": "BG4545", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242672.2, + 421045.3 + ], + "IO": "BG4545", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1601) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4500@3": { + "A": "0", + "B": "BG4500", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243528.6, + 436159.0 + ], + "IO": "BG4500", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (KR-M2110)", + "KENNZEICHNUNG": "=A01+UC0310-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4500@2": { + "A": "0", + "B": "BG4500", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244407.9, + 289658.4 + ], + "IO": "BG4500", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M1100)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0072@3": { + "A": "0", + "B": "MA0072", + "C": "20072710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244342.1, + 429657.7 + ], + "IO": "MA0072", + "ID": "9999", + "VERW": "KF -M0072_0,55", + "BEZEICHNUNG": "Motor MA0072 (KR-M2112)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ9", + "TEXT-D": "Motor MA0072", + "TEXT-E": "Motor MA0072", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0072@2": { + "A": "0", + "B": "MA0072", + "C": "20072710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240319.5, + 277741.6 + ], + "IO": "MA0072", + "ID": "9999", + "VERW": "ILS-CV M1501", + "BEZEICHNUNG": "Motor MA0072 (CV-M1501)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ8", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0072@1": { + "A": "0", + "B": "MA0072", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370718.9, + 180300.0 + ], + "IO": "MA0072", + "ID": "9999", + "VERW": "M0072 0,18", + "BEZEICHNUNG": "Motor 2 MA0072 Einfahren LS 1", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor 2 MA0072 Einfahren LS 1", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0072@4": { + "A": "0", + "B": "MA0072", + "C": "10072710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 380629.7, + 750198.5 + ], + "IO": "MA0072", + "ID": "9999", + "VERW": "ILS-CV-M4011", + "BEZEICHNUNG": "Motor MA0072 (ILS-CV-M4011)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG4503@3": { + "A": "0", + "B": "BG4503", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244342.1, + 431035.2 + ], + "IO": "BG4503", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (KR-M2110)", + "KENNZEICHNUNG": "=A01+UC0310-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4504@3": { + "A": "0", + "B": "BG4504", + "C": "20073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242299.4, + 430894.2 + ], + "IO": "BG4504", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M2110)", + "KENNZEICHNUNG": "=A01+UC0310-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4395@3": { + "A": "0", + "B": "BG4395", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242293.8, + 400551.2 + ], + "IO": "BG4395", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (KR-K2210 Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4507@3": { + "A": "0", + "B": "BG4507", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242289.3, + 429507.7 + ], + "IO": "BG4507", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor 3 (KR-K2210)", + "KENNZEICHNUNG": "=A01+UC0310-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4507@2": { + "A": "0", + "B": "BG4507", + "C": "20074500081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243229.6, + 280396.8 + ], + "IO": "BG4507", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (KR-M1100)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4396@3": { + "A": "0", + "B": "BG4396", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243631.4, + 398384.4 + ], + "IO": "BG4396", + "ID": "", + "VERW": "Rad dreht", + "BEZEICHNUNG": "Rad dreht (KR-K2210)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4150@3": { + "A": "0", + "B": "BG4150", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242955.6, + 417703.0 + ], + "IO": "BG4150", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M2302)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4150@2": { + "A": "0", + "B": "BG4150", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238488.1, + 267692.9 + ], + "IO": "BG4150", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M1302)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3916@3": { + "A": "0", + "B": "BG3916", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239627.0, + 422000.6 + ], + "IO": "BG3916", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M2204)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3436@3": { + "A": "0", + "B": "BG3436", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241406.9, + 440528.2 + ], + "IO": "BG3436", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M2104)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3436@5": { + "A": "0", + "B": "BG3436", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239596.5, + 151994.1 + ], + "IO": "BG3436", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M2111)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG4505@3": { + "A": "0", + "B": "BG4505", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242290.2, + 430492.5 + ], + "IO": "BG4505", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M2110)", + "KENNZEICHNUNG": "=A01+UC0310-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4505@2": { + "A": "0", + "B": "BG4505", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244473.8, + 280031.6 + ], + "IO": "BG4505", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (KR-M1100)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3786@3": { + "A": "0", + "B": "BG3786", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204256.3, + 420785.7 + ], + "IO": "BG3786", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M2203)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3786@2": { + "A": "0", + "B": "BG3786", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204256.3, + 270785.7 + ], + "IO": "BG3786", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M1203)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3785@3": { + "A": "0", + "B": "BG3785", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203727.2, + 421103.1 + ], + "IO": "BG3785", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 3 (KR-M2203)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3785@2": { + "A": "0", + "B": "BG3785", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203727.2, + 271103.1 + ], + "IO": "BG3785", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 3 (KR-M1203)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3306@3": { + "A": "0", + "B": "BG3306", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204250.9, + 440589.9 + ], + "IO": "BG3306", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M2103)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3306@2": { + "A": "0", + "B": "BG3306", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204250.9, + 290592.6 + ], + "IO": "BG3306", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M1103)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3306@5": { + "A": "0", + "B": "BG3306", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226319.0, + 150167.2 + ], + "IO": "BG3306", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "5" + }, + "BG3306@1": { + "A": "0", + "B": "BG3306", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 333164.0, + 152427.8 + ], + "IO": "BG3306", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG3305@3": { + "A": "0", + "B": "BG3305", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203508.4, + 440601.8 + ], + "IO": "BG3305", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (KR-M2103)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3305@2": { + "A": "0", + "B": "BG3305", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203478.5, + 290598.8 + ], + "IO": "BG3305", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 3 (KR-M1103)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3305@5": { + "A": "0", + "B": "BG3305", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220591.3, + 150883.9 + ], + "IO": "BG3305", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS CV-M5001)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "5" + }, + "BG3305@1": { + "A": "0", + "B": "BG3305", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 332559.0, + 153731.6 + ], + "IO": "BG3305", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV-M0103)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG4026@3": { + "A": "0", + "B": "BG4026", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204270.7, + 418602.8 + ], + "IO": "BG4026", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M2301)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4026@2": { + "A": "0", + "B": "BG4026", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204270.7, + 268602.8 + ], + "IO": "BG4026", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M1301)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4025@3": { + "A": "0", + "B": "BG4025", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203916.1, + 418344.7 + ], + "IO": "BG4025", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (KR-M2301)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4025@2": { + "A": "0", + "B": "BG4025", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203741.7, + 268344.7 + ], + "IO": "BG4025", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 3 (KR-M1301)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0060@3": { + "A": "0", + "B": "MA0060", + "C": "20063710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 169288.8, + 440351.6 + ], + "IO": "MA0060", + "ID": "9999", + "VERW": "KR-M2103 0,55", + "BEZEICHNUNG": "Motor MA0060 (KR-M2103)", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ4", + "TEXT-D": "Motor MA0060", + "TEXT-E": "Motor MA0060", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MA0060@2": { + "A": "0", + "B": "MA0060", + "C": "20063710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 169288.8, + 290410.6 + ], + "IO": "MA0060", + "ID": "9999", + "VERW": "ILS-KR-M1103", + "BEZEICHNUNG": "Motor MA0060 (KR-M1103)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ7", + "TEXT-D": "Motor MA0060", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0060@5": { + "A": "0", + "B": "MA0060", + "C": "10063710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1 - HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225218.9, + 149684.5 + ], + "IO": "MA0060", + "ID": "9999", + "VERW": "ILS-CV M5000", + "BEZEICHNUNG": "Motor MA0060 (ILS-CV M5000)", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "Motor MA0060", + "TEXT-E": "Motor MA0060", + "TEXT-ES": "", + "TEXT-F": "4G1,5mm² 20m", + "SPS": "5" + }, + "MA0060@4": { + "A": "0", + "B": "MA0060", + "C": "10063710081010151939", + "ARTINR": "790901001", + "BESCHR": "E-Teile für SEW Motor ASE1 - HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358556.7, + 724536.4 + ], + "IO": "MA0060", + "ID": "9999", + "VERW": "ILS-KR M4003", + "BEZEICHNUNG": "Motor MA0060 (ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MA0060@1": { + "A": "0", + "B": "MA0060", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 328267.3, + 165717.6 + ], + "IO": "MA0060", + "ID": "9999", + "VERW": "KR-M0101 0,55", + "BEZEICHNUNG": "Motor MA0060 (ILS-KR-M0101)", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor MA0060", + "TEXT-E": "Motor MA0060", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3965@3": { + "A": "0", + "B": "BG3965", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170987.2, + 418341.1 + ], + "IO": "BG3965", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (KR-M2301)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3965@2": { + "A": "0", + "B": "BG3965", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170988.5, + 268304.3 + ], + "IO": "BG3965", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (KR-M1301)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3725@3": { + "A": "0", + "B": "BG3725", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176343.8, + 420870.2 + ], + "IO": "BG3725", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (KR-M2203)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3725@2": { + "A": "0", + "B": "BG3725", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170660.3, + 270880.1 + ], + "IO": "BG3725", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (KR-M1203)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3245@3": { + "A": "0", + "B": "BG3245", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170876.7, + 440356.5 + ], + "IO": "BG3245", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (KR-M2103)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3245@2": { + "A": "0", + "B": "BG3245", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170687.9, + 290371.6 + ], + "IO": "BG3245", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (KR-M1103)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3245@5": { + "A": "0", + "B": "BG3245", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218685.4, + 153532.6 + ], + "IO": "BG3245", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M5003)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "5" + }, + "BG3245@4": { + "A": "0", + "B": "BG3245", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 362625.4, + 752187.3 + ], + "IO": "BG3245", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4001) ", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3245@1": { + "A": "0", + "B": "BG3245", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334191.9, + 166227.5 + ], + "IO": "BG3245", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (KR-K0111)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "MB4460@2": { + "A": "0", + "B": "MB4460", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241057.8, + 443032.3 + ], + "IO": "MB4460", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1401) ", + "KENNZEICHNUNG": "=A01+UC0209-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4575@3": { + "A": "0", + "B": "MB4575", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 245419.1, + 447217.7 + ], + "IO": "MB4575", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M4201)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4562@3": { + "A": "0", + "B": "MB4562", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 245255.0, + 448490.8 + ], + "IO": "MB4562", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M4101)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4562@2": { + "A": "0", + "B": "MB4562", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250977.2, + 295253.2 + ], + "IO": "MB4562", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV 1801)", + "KENNZEICHNUNG": "=A01+UC0211-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4560@3": { + "A": "0", + "B": "MB4560", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243083.2, + 448990.0 + ], + "IO": "MB4560", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (KR-M2110)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4566@3": { + "A": "0", + "B": "MB4566", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250493.0, + 448688.6 + ], + "IO": "MB4566", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M4101)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4572@3": { + "A": "0", + "B": "MB4572", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250526.1, + 446414.9 + ], + "IO": "MB4572", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M4201)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3045@3": { + "A": "0", + "B": "MB3045", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174007.5, + 458818.9 + ], + "IO": "MB3045", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3045@2": { + "A": "0", + "B": "MB3045", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174007.5, + 308818.9 + ], + "IO": "MB3045", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3046@3": { + "A": "0", + "B": "MB3046", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173207.5, + 458818.9 + ], + "IO": "MB3046", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3046@2": { + "A": "0", + "B": "MB3046", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173207.5, + 308818.9 + ], + "IO": "MB3046", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3047@3": { + "A": "0", + "B": "MB3047", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172429.9, + 458818.9 + ], + "IO": "MB3047", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3047@2": { + "A": "0", + "B": "MB3047", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172429.9, + 308818.9 + ], + "IO": "MB3047", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3050@3": { + "A": "0", + "B": "MB3050", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171655.7, + 458818.9 + ], + "IO": "MB3050", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3050@2": { + "A": "0", + "B": "MB3050", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171655.7, + 308818.9 + ], + "IO": "MB3050", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3051@3": { + "A": "0", + "B": "MB3051", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170882.8, + 458818.9 + ], + "IO": "MB3051", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.18 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3051@2": { + "A": "0", + "B": "MB3051", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170882.8, + 308818.9 + ], + "IO": "MB3051", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.18 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3052@3": { + "A": "0", + "B": "MB3052", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170129.0, + 458818.9 + ], + "IO": "MB3052", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.19 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3052@2": { + "A": "0", + "B": "MB3052", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170129.0, + 308818.9 + ], + "IO": "MB3052", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.19 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3030@3": { + "A": "0", + "B": "MB3030", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185949.6, + 458835.0 + ], + "IO": "MB3030", + "ID": "MB3030", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3030@2": { + "A": "0", + "B": "MB3030", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185949.6, + 308835.0 + ], + "IO": "MB3030", + "ID": "MB3030", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3031@3": { + "A": "0", + "B": "MB3031", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185149.5, + 458835.0 + ], + "IO": "MB3031", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3031@2": { + "A": "0", + "B": "MB3031", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185149.5, + 308835.0 + ], + "IO": "MB3031", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3032@3": { + "A": "0", + "B": "MB3032", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184348.7, + 458835.0 + ], + "IO": "MB3032", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3032@2": { + "A": "0", + "B": "MB3032", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184348.7, + 308835.0 + ], + "IO": "MB3032", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3033@3": { + "A": "0", + "B": "MB3033", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183549.5, + 458827.4 + ], + "IO": "MB3033", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3033@2": { + "A": "0", + "B": "MB3033", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183549.5, + 308827.4 + ], + "IO": "MB3033", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3034@3": { + "A": "0", + "B": "MB3034", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.5, + 458827.4 + ], + "IO": "MB3034", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3034@2": { + "A": "0", + "B": "MB3034", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.5, + 308827.4 + ], + "IO": "MB3034", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3035@3": { + "A": "0", + "B": "MB3035", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.5, + 458827.4 + ], + "IO": "MB3035", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3035@2": { + "A": "0", + "B": "MB3035", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.5, + 308827.4 + ], + "IO": "MB3035", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3036@3": { + "A": "0", + "B": "MB3036", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181149.5, + 458827.4 + ], + "IO": "MB3036", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3036@2": { + "A": "0", + "B": "MB3036", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181149.5, + 308827.4 + ], + "IO": "MB3036", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3000@3": { + "A": "0", + "B": "MB3000", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187132.0, + 458141.7 + ], + "IO": "MB3000", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3000@2": { + "A": "0", + "B": "MB3000", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187132.0, + 308141.7 + ], + "IO": "MB3000", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1105)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3004@3": { + "A": "0", + "B": "MB3004", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187127.8, + 457549.5 + ], + "IO": "MB3004", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3004@2": { + "A": "0", + "B": "MB3004", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187127.8, + 307549.5 + ], + "IO": "MB3004", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1105)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3044@3": { + "A": "0", + "B": "MB3044", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175153.1, + 458804.8 + ], + "IO": "MB3044", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3044@2": { + "A": "0", + "B": "MB3044", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175153.1, + 308804.8 + ], + "IO": "MB3044", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3043@3": { + "A": "0", + "B": "MB3043", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175953.1, + 458804.8 + ], + "IO": "MB3043", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3043@2": { + "A": "0", + "B": "MB3043", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175953.1, + 308804.8 + ], + "IO": "MB3043", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3042@3": { + "A": "0", + "B": "MB3042", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176751.8, + 458802.8 + ], + "IO": "MB3042", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3042@2": { + "A": "0", + "B": "MB3042", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176751.8, + 308802.8 + ], + "IO": "MB3042", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3041@3": { + "A": "0", + "B": "MB3041", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177538.8, + 458804.8 + ], + "IO": "MB3041", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3041@2": { + "A": "0", + "B": "MB3041", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177538.8, + 308804.8 + ], + "IO": "MB3041", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3040@3": { + "A": "0", + "B": "MB3040", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178351.8, + 458802.8 + ], + "IO": "MB3040", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3040@2": { + "A": "0", + "B": "MB3040", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178351.8, + 308802.8 + ], + "IO": "MB3040", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3037@3": { + "A": "0", + "B": "MB3037", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179151.8, + 458802.8 + ], + "IO": "MB3037", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC3101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3037@2": { + "A": "0", + "B": "MB3037", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179151.8, + 308802.8 + ], + "IO": "MB3037", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC2101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3150@3": { + "A": "0", + "B": "MB3150", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208060.1, + 458839.1 + ], + "IO": "MB3150", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3150@2": { + "A": "0", + "B": "MB3150", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208060.1, + 308839.1 + ], + "IO": "MB3150", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3151@3": { + "A": "0", + "B": "MB3151", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208838.3, + 458836.2 + ], + "IO": "MB3151", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3151@2": { + "A": "0", + "B": "MB3151", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208838.3, + 308836.2 + ], + "IO": "MB3151", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3152@3": { + "A": "0", + "B": "MB3152", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209638.3, + 458836.2 + ], + "IO": "MB3152", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3152@2": { + "A": "0", + "B": "MB3152", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209638.3, + 308836.2 + ], + "IO": "MB3152", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3153@3": { + "A": "0", + "B": "MB3153", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210612.9, + 458836.2 + ], + "IO": "MB3153", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3153@2": { + "A": "0", + "B": "MB3153", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210612.9, + 308836.2 + ], + "IO": "MB3153", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3154@3": { + "A": "0", + "B": "MB3154", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211472.9, + 458836.2 + ], + "IO": "MB3154", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3154@2": { + "A": "0", + "B": "MB3154", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211472.9, + 308836.2 + ], + "IO": "MB3154", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3155@3": { + "A": "0", + "B": "MB3155", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212272.9, + 458836.3 + ], + "IO": "MB3155", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3155@2": { + "A": "0", + "B": "MB3155", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212272.9, + 308836.3 + ], + "IO": "MB3155", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3156@3": { + "A": "0", + "B": "MB3156", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213072.0, + 458836.2 + ], + "IO": "MB3156", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3156@2": { + "A": "0", + "B": "MB3156", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213072.0, + 308836.2 + ], + "IO": "MB3156", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3157@3": { + "A": "0", + "B": "MB3157", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213842.9, + 458836.2 + ], + "IO": "MB3157", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3157@2": { + "A": "0", + "B": "MB3157", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213842.9, + 308836.2 + ], + "IO": "MB3157", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3160@3": { + "A": "0", + "B": "MB3160", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214672.9, + 458836.2 + ], + "IO": "MB3160", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3160@2": { + "A": "0", + "B": "MB3160", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214672.9, + 308836.2 + ], + "IO": "MB3160", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3161@3": { + "A": "0", + "B": "MB3161", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216418.1, + 458836.2 + ], + "IO": "MB3161", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3161@2": { + "A": "0", + "B": "MB3161", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216418.1, + 308836.2 + ], + "IO": "MB3161", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3162@3": { + "A": "0", + "B": "MB3162", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217218.1, + 458836.2 + ], + "IO": "MB3162", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3162@2": { + "A": "0", + "B": "MB3162", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217218.1, + 308836.2 + ], + "IO": "MB3162", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3163@3": { + "A": "0", + "B": "MB3163", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218018.1, + 458836.1 + ], + "IO": "MB3163", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3163@2": { + "A": "0", + "B": "MB3163", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218018.1, + 308836.1 + ], + "IO": "MB3163", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3164@3": { + "A": "0", + "B": "MB3164", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218817.3, + 458836.1 + ], + "IO": "MB3164", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3164@2": { + "A": "0", + "B": "MB3164", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218817.3, + 308836.1 + ], + "IO": "MB3164", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3165@3": { + "A": "0", + "B": "MB3165", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219618.1, + 458836.1 + ], + "IO": "MB3165", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3165@2": { + "A": "0", + "B": "MB3165", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219618.1, + 308836.1 + ], + "IO": "MB3165", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3166@3": { + "A": "0", + "B": "MB3166", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220418.1, + 458836.2 + ], + "IO": "MB3166", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3166@2": { + "A": "0", + "B": "MB3166", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220418.1, + 308836.2 + ], + "IO": "MB3166", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3167@3": { + "A": "0", + "B": "MB3167", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221218.1, + 458836.1 + ], + "IO": "MB3167", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3167@2": { + "A": "0", + "B": "MB3167", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221218.1, + 308836.1 + ], + "IO": "MB3167", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3170@3": { + "A": "0", + "B": "MB3170", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222418.1, + 458836.2 + ], + "IO": "MB3170", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3170@2": { + "A": "0", + "B": "MB3170", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222418.1, + 308836.2 + ], + "IO": "MB3170", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3171@3": { + "A": "0", + "B": "MB3171", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223218.1, + 458836.2 + ], + "IO": "MB3171", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.18 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3171@2": { + "A": "0", + "B": "MB3171", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223218.1, + 308836.2 + ], + "IO": "MB3171", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.18 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3172@3": { + "A": "0", + "B": "MB3172", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224018.1, + 458836.2 + ], + "IO": "MB3172", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.19 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3172@2": { + "A": "0", + "B": "MB3172", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224018.1, + 308836.2 + ], + "IO": "MB3172", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.19 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3173@3": { + "A": "0", + "B": "MB3173", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224818.1, + 458836.2 + ], + "IO": "MB3173", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.20 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3173@2": { + "A": "0", + "B": "MB3173", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224818.1, + 308836.2 + ], + "IO": "MB3173", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.20 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3174@3": { + "A": "0", + "B": "MB3174", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225618.1, + 458836.2 + ], + "IO": "MB3174", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.21 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3174@2": { + "A": "0", + "B": "MB3174", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225618.1, + 308836.2 + ], + "IO": "MB3174", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.21 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3137@3": { + "A": "0", + "B": "MB3137", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207625.0, + 459737.0 + ], + "IO": "MB3137", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3137@2": { + "A": "0", + "B": "MB3137", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207135.3, + 310080.7 + ], + "IO": "MB3137", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3244@3": { + "A": "0", + "B": "MB3244", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187189.2, + 442915.6 + ], + "IO": "MB3244", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2105) ", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3244@2": { + "A": "0", + "B": "MB3244", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187300.2, + 292872.5 + ], + "IO": "MB3244", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1105)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3240@3": { + "A": "0", + "B": "MB3240", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186664.6, + 441334.7 + ], + "IO": "MB3240", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3240@2": { + "A": "0", + "B": "MB3240", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186664.6, + 291334.7 + ], + "IO": "MB3240", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3240@5": { + "A": "0", + "B": "MB3240", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216938.3, + 150317.5 + ], + "IO": "MB3240", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "5" + }, + "MB3292@3": { + "A": "0", + "B": "MB3292", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 442937.5 + ], + "IO": "MB3292", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 19 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3292@2": { + "A": "0", + "B": "MB3292", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 292937.5 + ], + "IO": "MB3292", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 19 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3283@3": { + "A": "0", + "B": "MB3283", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 442937.6 + ], + "IO": "MB3283", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3283@2": { + "A": "0", + "B": "MB3283", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 292937.6 + ], + "IO": "MB3283", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3283@1": { + "A": "0", + "B": "MB3283", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337121.7, + 163278.9 + ], + "IO": "MB3283", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M0107)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 15m", + "SPS": "1" + }, + "MB3282@3": { + "A": "0", + "B": "MB3282", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 442937.6 + ], + "IO": "MB3282", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3282@2": { + "A": "0", + "B": "MB3282", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 292937.6 + ], + "IO": "MB3282", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3281@3": { + "A": "0", + "B": "MB3281", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 442937.6 + ], + "IO": "MB3281", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3281@2": { + "A": "0", + "B": "MB3281", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 292937.6 + ], + "IO": "MB3281", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3280@3": { + "A": "0", + "B": "MB3280", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 442937.6 + ], + "IO": "MB3280", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3280@2": { + "A": "0", + "B": "MB3280", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 292937.6 + ], + "IO": "MB3280", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3280@1": { + "A": "0", + "B": "MB3280", + "C": "20073710081010151939", + "ARTINR": "722001306", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 20m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334141.1, + 159432.0 + ], + "IO": "MB3280", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-BX1104)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 20m", + "SPS": "1" + }, + "MB3277@3": { + "A": "0", + "B": "MB3277", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 442937.6 + ], + "IO": "MB3277", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3277@2": { + "A": "0", + "B": "MB3277", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 292937.6 + ], + "IO": "MB3277", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3286@3": { + "A": "0", + "B": "MB3286", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 442937.5 + ], + "IO": "MB3286", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3286@2": { + "A": "0", + "B": "MB3286", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 292937.5 + ], + "IO": "MB3286", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3285@3": { + "A": "0", + "B": "MB3285", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 442937.5 + ], + "IO": "MB3285", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3285@2": { + "A": "0", + "B": "MB3285", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 292937.5 + ], + "IO": "MB3285", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3284@3": { + "A": "0", + "B": "MB3284", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 442937.6 + ], + "IO": "MB3284", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3284@2": { + "A": "0", + "B": "MB3284", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 292937.6 + ], + "IO": "MB3284", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3287@3": { + "A": "0", + "B": "MB3287", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 442937.5 + ], + "IO": "MB3287", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3287@2": { + "A": "0", + "B": "MB3287", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 292937.5 + ], + "IO": "MB3287", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3291@3": { + "A": "0", + "B": "MB3291", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 442937.5 + ], + "IO": "MB3291", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 18 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3291@2": { + "A": "0", + "B": "MB3291", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 292937.5 + ], + "IO": "MB3291", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 18 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3276@3": { + "A": "0", + "B": "MB3276", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 442937.6 + ], + "IO": "MB3276", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3276@2": { + "A": "0", + "B": "MB3276", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 292937.6 + ], + "IO": "MB3276", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3275@3": { + "A": "0", + "B": "MB3275", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 442937.6 + ], + "IO": "MB3275", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3275@2": { + "A": "0", + "B": "MB3275", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 292937.6 + ], + "IO": "MB3275", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3274@3": { + "A": "0", + "B": "MB3274", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 442937.6 + ], + "IO": "MB3274", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3274@2": { + "A": "0", + "B": "MB3274", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 292937.6 + ], + "IO": "MB3274", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3273@3": { + "A": "0", + "B": "MB3273", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 442937.6 + ], + "IO": "MB3273", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3273@2": { + "A": "0", + "B": "MB3273", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 292937.6 + ], + "IO": "MB3273", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3272@3": { + "A": "0", + "B": "MB3272", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 442937.6 + ], + "IO": "MB3272", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3272@2": { + "A": "0", + "B": "MB3272", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 292937.6 + ], + "IO": "MB3272", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3271@3": { + "A": "0", + "B": "MB3271", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 442937.6 + ], + "IO": "MB3271", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3271@2": { + "A": "0", + "B": "MB3271", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 292937.6 + ], + "IO": "MB3271", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3271@1": { + "A": "0", + "B": "MB3271", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331115.1, + 163321.1 + ], + "IO": "MB3271", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M0103)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 15m", + "SPS": "1" + }, + "MB3270@3": { + "A": "0", + "B": "MB3270", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 442937.6 + ], + "IO": "MB3270", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.1.1)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3270@2": { + "A": "0", + "B": "MB3270", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 292937.6 + ], + "IO": "MB3270", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.1.1)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3064@3": { + "A": "0", + "B": "MB3064", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204364.4, + 457549.5 + ], + "IO": "MB3064", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3064@2": { + "A": "0", + "B": "MB3064", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204364.4, + 307549.5 + ], + "IO": "MB3064", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1106)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3090@3": { + "A": "0", + "B": "MB3090", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.8, + 458810.4 + ], + "IO": "MB3090", + "ID": "MB3090", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3090@2": { + "A": "0", + "B": "MB3090", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.8, + 308810.4 + ], + "IO": "MB3090", + "ID": "MB3090", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3091@3": { + "A": "0", + "B": "MB3091", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.7, + 458810.4 + ], + "IO": "MB3091", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3091@2": { + "A": "0", + "B": "MB3091", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.7, + 308810.4 + ], + "IO": "MB3091", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3092@3": { + "A": "0", + "B": "MB3092", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 458810.4 + ], + "IO": "MB3092", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3092@2": { + "A": "0", + "B": "MB3092", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 308810.4 + ], + "IO": "MB3092", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3093@3": { + "A": "0", + "B": "MB3093", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.7, + 458802.8 + ], + "IO": "MB3093", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3093@2": { + "A": "0", + "B": "MB3093", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.7, + 308802.8 + ], + "IO": "MB3093", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3094@3": { + "A": "0", + "B": "MB3094", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.7, + 458802.8 + ], + "IO": "MB3094", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3094@2": { + "A": "0", + "B": "MB3094", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.7, + 308802.8 + ], + "IO": "MB3094", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3095@3": { + "A": "0", + "B": "MB3095", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.7, + 458802.8 + ], + "IO": "MB3095", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3095@2": { + "A": "0", + "B": "MB3095", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.7, + 308802.8 + ], + "IO": "MB3095", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3096@3": { + "A": "0", + "B": "MB3096", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.7, + 458802.8 + ], + "IO": "MB3096", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3096@2": { + "A": "0", + "B": "MB3096", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.7, + 308802.8 + ], + "IO": "MB3096", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3097@3": { + "A": "0", + "B": "MB3097", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.9, + 458802.8 + ], + "IO": "MB3097", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3097@2": { + "A": "0", + "B": "MB3097", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.9, + 308802.8 + ], + "IO": "MB3097", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3104@3": { + "A": "0", + "B": "MB3104", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193103.3, + 458804.8 + ], + "IO": "MB3104", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3104@2": { + "A": "0", + "B": "MB3104", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193103.3, + 308804.8 + ], + "IO": "MB3104", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3103@3": { + "A": "0", + "B": "MB3103", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193903.3, + 458804.8 + ], + "IO": "MB3103", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3103@2": { + "A": "0", + "B": "MB3103", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193903.3, + 308804.8 + ], + "IO": "MB3103", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3102@3": { + "A": "0", + "B": "MB3102", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194702.0, + 458802.8 + ], + "IO": "MB3102", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3102@2": { + "A": "0", + "B": "MB3102", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194702.0, + 308802.8 + ], + "IO": "MB3102", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3101@3": { + "A": "0", + "B": "MB3101", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195489.0, + 458804.8 + ], + "IO": "MB3101", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3101@2": { + "A": "0", + "B": "MB3101", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195489.0, + 308804.8 + ], + "IO": "MB3101", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3100@3": { + "A": "0", + "B": "MB3100", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196302.0, + 458802.8 + ], + "IO": "MB3100", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3100@2": { + "A": "0", + "B": "MB3100", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196302.0, + 308802.8 + ], + "IO": "MB3100", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3105@3": { + "A": "0", + "B": "MB3105", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191307.5, + 458818.9 + ], + "IO": "MB3105", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3105@2": { + "A": "0", + "B": "MB3105", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191307.5, + 308818.9 + ], + "IO": "MB3105", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3106@3": { + "A": "0", + "B": "MB3106", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190507.5, + 458818.9 + ], + "IO": "MB3106", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3106@2": { + "A": "0", + "B": "MB3106", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190507.5, + 308818.9 + ], + "IO": "MB3106", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3107@3": { + "A": "0", + "B": "MB3107", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189729.9, + 458818.9 + ], + "IO": "MB3107", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3107@2": { + "A": "0", + "B": "MB3107", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189729.9, + 308818.9 + ], + "IO": "MB3107", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3110@3": { + "A": "0", + "B": "MB3110", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188955.7, + 458818.9 + ], + "IO": "MB3110", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3110@2": { + "A": "0", + "B": "MB3110", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188955.7, + 308818.9 + ], + "IO": "MB3110", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3124@3": { + "A": "0", + "B": "MB3124", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206614.4, + 457709.4 + ], + "IO": "MB3124", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3124@2": { + "A": "0", + "B": "MB3124", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206614.4, + 307439.4 + ], + "IO": "MB3124", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3180@3": { + "A": "0", + "B": "MB3180", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227619.3, + 458127.7 + ], + "IO": "MB3180", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3180@2": { + "A": "0", + "B": "MB3180", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227619.3, + 308127.7 + ], + "IO": "MB3180", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3184@3": { + "A": "0", + "B": "MB3184", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227614.4, + 457545.6 + ], + "IO": "MB3184", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3184@2": { + "A": "0", + "B": "MB3184", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227614.4, + 307545.6 + ], + "IO": "MB3184", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3210@3": { + "A": "0", + "B": "MB3210", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228810.1, + 458839.1 + ], + "IO": "MB3210", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3210@2": { + "A": "0", + "B": "MB3210", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228810.1, + 308839.1 + ], + "IO": "MB3210", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3211@3": { + "A": "0", + "B": "MB3211", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229588.3, + 458836.2 + ], + "IO": "MB3211", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3211@2": { + "A": "0", + "B": "MB3211", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229588.3, + 308836.2 + ], + "IO": "MB3211", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3212@3": { + "A": "0", + "B": "MB3212", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230388.3, + 458836.2 + ], + "IO": "MB3212", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3212@2": { + "A": "0", + "B": "MB3212", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230388.3, + 308836.2 + ], + "IO": "MB3212", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3213@3": { + "A": "0", + "B": "MB3213", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231151.3, + 458836.2 + ], + "IO": "MB3213", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3213@2": { + "A": "0", + "B": "MB3213", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231151.3, + 308836.2 + ], + "IO": "MB3213", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3214@3": { + "A": "0", + "B": "MB3214", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231994.8, + 458836.2 + ], + "IO": "MB3214", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3214@2": { + "A": "0", + "B": "MB3214", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231994.8, + 308836.2 + ], + "IO": "MB3214", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3215@3": { + "A": "0", + "B": "MB3215", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232794.8, + 458836.3 + ], + "IO": "MB3215", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3215@2": { + "A": "0", + "B": "MB3215", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232794.8, + 308836.3 + ], + "IO": "MB3215", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3216@3": { + "A": "0", + "B": "MB3216", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233593.9, + 458836.2 + ], + "IO": "MB3216", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3216@2": { + "A": "0", + "B": "MB3216", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233593.9, + 308836.2 + ], + "IO": "MB3216", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3217@3": { + "A": "0", + "B": "MB3217", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234481.5, + 458836.2 + ], + "IO": "MB3217", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3217@2": { + "A": "0", + "B": "MB3217", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234481.5, + 308836.2 + ], + "IO": "MB3217", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3220@3": { + "A": "0", + "B": "MB3220", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235311.5, + 458836.2 + ], + "IO": "MB3220", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3220@2": { + "A": "0", + "B": "MB3220", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235311.5, + 308836.2 + ], + "IO": "MB3220", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3221@3": { + "A": "0", + "B": "MB3221", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236139.7, + 458836.2 + ], + "IO": "MB3221", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3221@2": { + "A": "0", + "B": "MB3221", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236139.7, + 308836.2 + ], + "IO": "MB3221", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3222@3": { + "A": "0", + "B": "MB3222", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236939.7, + 458836.2 + ], + "IO": "MB3222", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3222@2": { + "A": "0", + "B": "MB3222", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236939.7, + 308836.2 + ], + "IO": "MB3222", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3223@3": { + "A": "0", + "B": "MB3223", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237739.7, + 458836.1 + ], + "IO": "MB3223", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3223@2": { + "A": "0", + "B": "MB3223", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237739.7, + 308836.1 + ], + "IO": "MB3223", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3224@3": { + "A": "0", + "B": "MB3224", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238538.9, + 458836.1 + ], + "IO": "MB3224", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3224@2": { + "A": "0", + "B": "MB3224", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238538.9, + 308836.1 + ], + "IO": "MB3224", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC2104-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3304@3": { + "A": "0", + "B": "MB3304", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204428.4, + 442923.9 + ], + "IO": "MB3304", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2106) ", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3304@2": { + "A": "0", + "B": "MB3304", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204500.2, + 292877.9 + ], + "IO": "MB3304", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1106 Block 1.1.2) ", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3304@5": { + "A": "0", + "B": "MB3304", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222532.5, + 149052.8 + ], + "IO": "MB3304", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS CV-M5001)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 15m", + "SPS": "5" + }, + "MB3304@4": { + "A": "0", + "B": "MB3304", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356209.0, + 727679.8 + ], + "IO": "MB3304", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (AMR KR-M4003)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3304@1": { + "A": "0", + "B": "MB3304", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331080.8, + 152688.4 + ], + "IO": "MB3304", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3300@3": { + "A": "0", + "B": "MB3300", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203430.1, + 441358.2 + ], + "IO": "MB3300", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (KR-M2103 Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3300@2": { + "A": "0", + "B": "MB3300", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203430.1, + 291358.2 + ], + "IO": "MB3300", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3300@4": { + "A": "0", + "B": "MB3300", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358556.7, + 726010.0 + ], + "IO": "MB3300", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (AMR KR-M4003)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3300@1": { + "A": "0", + "B": "MB3300", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329991.3, + 151779.4 + ], + "IO": "MB3300", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 15m", + "SPS": "1" + }, + "MB3301@3": { + "A": "0", + "B": "MB3301", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204389.0, + 442032.9 + ], + "IO": "MB3301", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M2106 Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3301@2": { + "A": "0", + "B": "MB3301", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204389.0, + 292032.9 + ], + "IO": "MB3301", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1106 Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3301@5": { + "A": "0", + "B": "MB3301", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224376.1, + 150116.3 + ], + "IO": "MB3301", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS CV-M5000)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 15m", + "SPS": "5" + }, + "MB3336@3": { + "A": "0", + "B": "MB3336", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 442937.6 + ], + "IO": "MB3336", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3336@2": { + "A": "0", + "B": "MB3336", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 292937.6 + ], + "IO": "MB3336", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3335@3": { + "A": "0", + "B": "MB3335", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 442937.6 + ], + "IO": "MB3335", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3335@2": { + "A": "0", + "B": "MB3335", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 292937.6 + ], + "IO": "MB3335", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3335@1": { + "A": "0", + "B": "MB3335", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340147.1, + 152451.2 + ], + "IO": "MB3335", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3334@3": { + "A": "0", + "B": "MB3334", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 442937.6 + ], + "IO": "MB3334", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3334@2": { + "A": "0", + "B": "MB3334", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 292937.6 + ], + "IO": "MB3334", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3333@3": { + "A": "0", + "B": "MB3333", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.0, + 442937.6 + ], + "IO": "MB3333", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3333@2": { + "A": "0", + "B": "MB3333", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.0, + 292937.6 + ], + "IO": "MB3333", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3333@5": { + "A": "0", + "B": "MB3333", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241245.6, + 302325.1 + ], + "IO": "MB3333", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M5001) ", + "KENNZEICHNUNG": "=A01+UC0502-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3332@3": { + "A": "0", + "B": "MB3332", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 442937.6 + ], + "IO": "MB3332", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3332@2": { + "A": "0", + "B": "MB3332", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 292937.6 + ], + "IO": "MB3332", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3332@1": { + "A": "0", + "B": "MB3332", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 338655.7, + 152697.8 + ], + "IO": "MB3332", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3331@3": { + "A": "0", + "B": "MB3331", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 442937.6 + ], + "IO": "MB3331", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3331@2": { + "A": "0", + "B": "MB3331", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 292937.6 + ], + "IO": "MB3331", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3330@3": { + "A": "0", + "B": "MB3330", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 442937.6 + ], + "IO": "MB3330", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3330@2": { + "A": "0", + "B": "MB3330", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 292937.6 + ], + "IO": "MB3330", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3330@5": { + "A": "0", + "B": "MB3330", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243203.2, + 302980.2 + ], + "IO": "MB3330", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M5000) ", + "KENNZEICHNUNG": "=A01+UC0502-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3330@1": { + "A": "0", + "B": "MB3330", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337069.1, + 152688.4 + ], + "IO": "MB3330", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 5m", + "SPS": "1" + }, + "MB3343@3": { + "A": "0", + "B": "MB3343", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193900.0, + 442937.6 + ], + "IO": "MB3343", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3343@2": { + "A": "0", + "B": "MB3343", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193900.0, + 292937.6 + ], + "IO": "MB3343", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3342@3": { + "A": "0", + "B": "MB3342", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194700.0, + 442937.6 + ], + "IO": "MB3342", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3342@2": { + "A": "0", + "B": "MB3342", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194700.0, + 292937.6 + ], + "IO": "MB3342", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3341@3": { + "A": "0", + "B": "MB3341", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195500.0, + 442937.6 + ], + "IO": "MB3341", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3341@2": { + "A": "0", + "B": "MB3341", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195500.0, + 292937.6 + ], + "IO": "MB3341", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3340@3": { + "A": "0", + "B": "MB3340", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196300.0, + 442937.6 + ], + "IO": "MB3340", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3340@2": { + "A": "0", + "B": "MB3340", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196300.0, + 292937.6 + ], + "IO": "MB3340", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3340@1": { + "A": "0", + "B": "MB3340", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 343100.0, + 153520.7 + ], + "IO": "MB3340", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig (ILS-KR M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 15m", + "SPS": "1" + }, + "MB3337@3": { + "A": "0", + "B": "MB3337", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.0, + 442937.6 + ], + "IO": "MB3337", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3337@2": { + "A": "0", + "B": "MB3337", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.0, + 292937.6 + ], + "IO": "MB3337", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3337@1": { + "A": "0", + "B": "MB3337", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 342176.9, + 153982.2 + ], + "IO": "MB3337", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 15m", + "SPS": "1" + }, + "MB3344@3": { + "A": "0", + "B": "MB3344", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193100.0, + 442937.6 + ], + "IO": "MB3344", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3344@2": { + "A": "0", + "B": "MB3344", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193100.0, + 292937.6 + ], + "IO": "MB3344", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3346@3": { + "A": "0", + "B": "MB3346", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 442937.6 + ], + "IO": "MB3346", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3346@2": { + "A": "0", + "B": "MB3346", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 292937.6 + ], + "IO": "MB3346", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3345@3": { + "A": "0", + "B": "MB3345", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 442937.6 + ], + "IO": "MB3345", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3345@2": { + "A": "0", + "B": "MB3345", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 292937.6 + ], + "IO": "MB3345", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3347@3": { + "A": "0", + "B": "MB3347", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.0, + 442937.6 + ], + "IO": "MB3347", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3347@2": { + "A": "0", + "B": "MB3347", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.0, + 292937.6 + ], + "IO": "MB3347", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3350@3": { + "A": "0", + "B": "MB3350", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 442937.6 + ], + "IO": "MB3350", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 2.1.2)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3350@2": { + "A": "0", + "B": "MB3350", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 292937.6 + ], + "IO": "MB3350", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 1.1.2)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3364@3": { + "A": "0", + "B": "MB3364", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206540.2, + 442883.2 + ], + "IO": "MB3364", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2107)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3364@2": { + "A": "0", + "B": "MB3364", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206540.2, + 292877.9 + ], + "IO": "MB3364", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1107) ", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3364@5": { + "A": "0", + "B": "MB3364", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225298.5, + 155923.1 + ], + "IO": "MB3364", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3361@3": { + "A": "0", + "B": "MB3361", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206540.2, + 442048.1 + ], + "IO": "MB3361", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M2107 Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3361@2": { + "A": "0", + "B": "MB3361", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206659.0, + 292032.9 + ], + "IO": "MB3361", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1107)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3361@5": { + "A": "0", + "B": "MB3361", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226556.1, + 151729.8 + ], + "IO": "MB3361", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3360@3": { + "A": "0", + "B": "MB3360", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207829.4, + 441467.5 + ], + "IO": "MB3360", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3360@2": { + "A": "0", + "B": "MB3360", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207893.0, + 291466.8 + ], + "IO": "MB3360", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3360@5": { + "A": "0", + "B": "MB3360", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225042.0, + 152465.8 + ], + "IO": "MB3360", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3360@4": { + "A": "0", + "B": "MB3360", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358297.5, + 738537.2 + ], + "IO": "MB3360", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3390@3": { + "A": "0", + "B": "MB3390", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208400.0, + 442937.6 + ], + "IO": "MB3390", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3390@2": { + "A": "0", + "B": "MB3390", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208400.0, + 292937.6 + ], + "IO": "MB3390", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3391@3": { + "A": "0", + "B": "MB3391", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209200.0, + 442937.6 + ], + "IO": "MB3391", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3391@2": { + "A": "0", + "B": "MB3391", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209200.0, + 292937.6 + ], + "IO": "MB3391", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3391@4": { + "A": "0", + "B": "MB3391", + "C": "10073710081010151939", + "ARTINR": "722001306", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 20m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359609.5, + 744039.1 + ], + "IO": "MB3391", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (AMR ILS-CV M4010)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3392@3": { + "A": "0", + "B": "MB3392", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210000.0, + 442937.6 + ], + "IO": "MB3392", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3392@2": { + "A": "0", + "B": "MB3392", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210000.0, + 292937.6 + ], + "IO": "MB3392", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3393@3": { + "A": "0", + "B": "MB3393", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211150.0, + 442937.6 + ], + "IO": "MB3393", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3393@2": { + "A": "0", + "B": "MB3393", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211150.0, + 292937.6 + ], + "IO": "MB3393", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3394@3": { + "A": "0", + "B": "MB3394", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211950.0, + 442937.6 + ], + "IO": "MB3394", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3394@2": { + "A": "0", + "B": "MB3394", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211950.0, + 292937.6 + ], + "IO": "MB3394", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3395@3": { + "A": "0", + "B": "MB3395", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212750.0, + 442937.6 + ], + "IO": "MB3395", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3395@2": { + "A": "0", + "B": "MB3395", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212750.0, + 292937.6 + ], + "IO": "MB3395", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3396@3": { + "A": "0", + "B": "MB3396", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213550.0, + 442937.6 + ], + "IO": "MB3396", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3396@2": { + "A": "0", + "B": "MB3396", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213550.0, + 292937.6 + ], + "IO": "MB3396", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3397@3": { + "A": "0", + "B": "MB3397", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214350.0, + 442937.6 + ], + "IO": "MB3397", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3397@2": { + "A": "0", + "B": "MB3397", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214350.0, + 292937.6 + ], + "IO": "MB3397", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3400@3": { + "A": "0", + "B": "MB3400", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215150.0, + 442937.6 + ], + "IO": "MB3400", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3400@2": { + "A": "0", + "B": "MB3400", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215150.0, + 292937.6 + ], + "IO": "MB3400", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3401@3": { + "A": "0", + "B": "MB3401", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217150.0, + 442937.6 + ], + "IO": "MB3401", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3401@2": { + "A": "0", + "B": "MB3401", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217150.0, + 292937.6 + ], + "IO": "MB3401", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3402@3": { + "A": "0", + "B": "MB3402", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217950.0, + 442937.6 + ], + "IO": "MB3402", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3402@2": { + "A": "0", + "B": "MB3402", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217950.0, + 292937.6 + ], + "IO": "MB3402", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3403@3": { + "A": "0", + "B": "MB3403", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218750.0, + 442937.6 + ], + "IO": "MB3403", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3403@2": { + "A": "0", + "B": "MB3403", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218750.0, + 292937.6 + ], + "IO": "MB3403", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3404@3": { + "A": "0", + "B": "MB3404", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219550.0, + 442937.6 + ], + "IO": "MB3404", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3404@2": { + "A": "0", + "B": "MB3404", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219550.0, + 292937.6 + ], + "IO": "MB3404", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3405@3": { + "A": "0", + "B": "MB3405", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220350.0, + 442937.6 + ], + "IO": "MB3405", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3405@2": { + "A": "0", + "B": "MB3405", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220350.0, + 292937.6 + ], + "IO": "MB3405", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3406@3": { + "A": "0", + "B": "MB3406", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221150.0, + 442937.6 + ], + "IO": "MB3406", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3406@2": { + "A": "0", + "B": "MB3406", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221150.0, + 292937.6 + ], + "IO": "MB3406", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3407@3": { + "A": "0", + "B": "MB3407", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221950.0, + 442937.6 + ], + "IO": "MB3407", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3407@2": { + "A": "0", + "B": "MB3407", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221950.0, + 292937.6 + ], + "IO": "MB3407", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3410@3": { + "A": "0", + "B": "MB3410", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223150.0, + 442937.6 + ], + "IO": "MB3410", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3410@2": { + "A": "0", + "B": "MB3410", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223150.0, + 292937.6 + ], + "IO": "MB3410", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3411@3": { + "A": "0", + "B": "MB3411", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223950.0, + 442937.6 + ], + "IO": "MB3411", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 18 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3411@2": { + "A": "0", + "B": "MB3411", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223950.0, + 292937.6 + ], + "IO": "MB3411", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 18 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3412@3": { + "A": "0", + "B": "MB3412", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224750.0, + 442937.6 + ], + "IO": "MB3412", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 19 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3412@2": { + "A": "0", + "B": "MB3412", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224750.0, + 292937.6 + ], + "IO": "MB3412", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 19 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3413@3": { + "A": "0", + "B": "MB3413", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225550.0, + 442937.6 + ], + "IO": "MB3413", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 20 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3413@2": { + "A": "0", + "B": "MB3413", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225550.0, + 292937.6 + ], + "IO": "MB3413", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 20 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3414@3": { + "A": "0", + "B": "MB3414", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226350.0, + 442937.6 + ], + "IO": "MB3414", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 21 (Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3414@2": { + "A": "0", + "B": "MB3414", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226350.0, + 292937.6 + ], + "IO": "MB3414", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 21 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3424@3": { + "A": "0", + "B": "MB3424", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 442874.1 + ], + "IO": "MB3424", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2108) ", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3424@2": { + "A": "0", + "B": "MB3424", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 292885.3 + ], + "IO": "MB3424", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1108)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3424@5": { + "A": "0", + "B": "MB3424", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234162.4, + 155923.6 + ], + "IO": "MB3424", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3424@4": { + "A": "0", + "B": "MB3424", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359648.7, + 750557.3 + ], + "IO": "MB3424", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (AMR ILS-CV M4010)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3421@3": { + "A": "0", + "B": "MB3421", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.8, + 442033.0 + ], + "IO": "MB3421", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M2108) ", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3421@2": { + "A": "0", + "B": "MB3421", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.8, + 292033.0 + ], + "IO": "MB3421", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M1108 Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3421@5": { + "A": "0", + "B": "MB3421", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235406.1, + 151729.8 + ], + "IO": "MB3421", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3420@3": { + "A": "0", + "B": "MB3420", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228310.7, + 441483.4 + ], + "IO": "MB3420", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3420@2": { + "A": "0", + "B": "MB3420", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228310.7, + 291483.4 + ], + "IO": "MB3420", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3420@5": { + "A": "0", + "B": "MB3420", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233694.0, + 152407.1 + ], + "IO": "MB3420", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3420@4": { + "A": "0", + "B": "MB3420", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359629.3, + 752448.5 + ], + "IO": "MB3420", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (AMR ILS-CV M4002)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3134@3": { + "A": "0", + "B": "MB3134", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224498.3, + 460129.1 + ], + "IO": "MB3134", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (KR-M2102 Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3134@2": { + "A": "0", + "B": "MB3134", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212479.5, + 310811.6 + ], + "IO": "MB3134", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3425@3": { + "A": "0", + "B": "MB3425", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237420.4, + 441401.7 + ], + "IO": "MB3425", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (ILS-CV M2104 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3425@2": { + "A": "0", + "B": "MB3425", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227170.7, + 290412.1 + ], + "IO": "MB3425", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (ILS-CV M1104)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3450@3": { + "A": "0", + "B": "MB3450", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 442937.6 + ], + "IO": "MB3450", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3450@2": { + "A": "0", + "B": "MB3450", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 292937.6 + ], + "IO": "MB3450", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3451@3": { + "A": "0", + "B": "MB3451", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 442937.6 + ], + "IO": "MB3451", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3451@2": { + "A": "0", + "B": "MB3451", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 292937.6 + ], + "IO": "MB3451", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3451@4": { + "A": "0", + "B": "MB3451", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355970.4, + 751702.4 + ], + "IO": "MB3451", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator Ausfahrt MPS 1 (AMR ILS-CV M4009)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3452@3": { + "A": "0", + "B": "MB3452", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 442937.6 + ], + "IO": "MB3452", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3452@2": { + "A": "0", + "B": "MB3452", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 292937.6 + ], + "IO": "MB3452", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3453@3": { + "A": "0", + "B": "MB3453", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 442937.6 + ], + "IO": "MB3453", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3453@2": { + "A": "0", + "B": "MB3453", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 292937.6 + ], + "IO": "MB3453", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3454@3": { + "A": "0", + "B": "MB3454", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 442937.6 + ], + "IO": "MB3454", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3454@2": { + "A": "0", + "B": "MB3454", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 292937.6 + ], + "IO": "MB3454", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3455@3": { + "A": "0", + "B": "MB3455", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 442937.6 + ], + "IO": "MB3455", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3455@2": { + "A": "0", + "B": "MB3455", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 292937.6 + ], + "IO": "MB3455", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3456@3": { + "A": "0", + "B": "MB3456", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 442937.6 + ], + "IO": "MB3456", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3456@2": { + "A": "0", + "B": "MB3456", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 292937.6 + ], + "IO": "MB3456", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3457@3": { + "A": "0", + "B": "MB3457", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 442937.6 + ], + "IO": "MB3457", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3457@2": { + "A": "0", + "B": "MB3457", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 292937.6 + ], + "IO": "MB3457", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3460@3": { + "A": "0", + "B": "MB3460", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 442937.6 + ], + "IO": "MB3460", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3460@2": { + "A": "0", + "B": "MB3460", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 292937.6 + ], + "IO": "MB3460", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3461@3": { + "A": "0", + "B": "MB3461", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 442937.6 + ], + "IO": "MB3461", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3461@2": { + "A": "0", + "B": "MB3461", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 292937.6 + ], + "IO": "MB3461", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3462@3": { + "A": "0", + "B": "MB3462", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 442937.6 + ], + "IO": "MB3462", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3462@2": { + "A": "0", + "B": "MB3462", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 292937.6 + ], + "IO": "MB3462", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3463@3": { + "A": "0", + "B": "MB3463", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 442937.6 + ], + "IO": "MB3463", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3463@2": { + "A": "0", + "B": "MB3463", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 292937.6 + ], + "IO": "MB3463", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3464@3": { + "A": "0", + "B": "MB3464", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239150.0, + 442937.6 + ], + "IO": "MB3464", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3464@2": { + "A": "0", + "B": "MB3464", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239150.0, + 292937.6 + ], + "IO": "MB3464", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3241@3": { + "A": "0", + "B": "MB3241", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187189.0, + 442032.9 + ], + "IO": "MB3241", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M2105)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3241@2": { + "A": "0", + "B": "MB3241", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187189.0, + 292032.9 + ], + "IO": "MB3241", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M1105)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3510@3": { + "A": "0", + "B": "MB3510", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185949.6, + 437835.0 + ], + "IO": "MB3510", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3510@2": { + "A": "0", + "B": "MB3510", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185949.6, + 287835.0 + ], + "IO": "MB3510", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3511@3": { + "A": "0", + "B": "MB3511", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185149.5, + 437835.0 + ], + "IO": "MB3511", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3511@2": { + "A": "0", + "B": "MB3511", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185149.5, + 287835.0 + ], + "IO": "MB3511", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3512@3": { + "A": "0", + "B": "MB3512", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184348.7, + 437835.0 + ], + "IO": "MB3512", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3512@2": { + "A": "0", + "B": "MB3512", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184348.7, + 287835.0 + ], + "IO": "MB3512", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3513@3": { + "A": "0", + "B": "MB3513", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183549.5, + 437827.4 + ], + "IO": "MB3513", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3513@2": { + "A": "0", + "B": "MB3513", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183549.5, + 287827.4 + ], + "IO": "MB3513", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3514@3": { + "A": "0", + "B": "MB3514", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.5, + 437827.4 + ], + "IO": "MB3514", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3514@2": { + "A": "0", + "B": "MB3514", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.5, + 287827.4 + ], + "IO": "MB3514", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3515@3": { + "A": "0", + "B": "MB3515", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.5, + 437827.4 + ], + "IO": "MB3515", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3515@2": { + "A": "0", + "B": "MB3515", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.5, + 287827.4 + ], + "IO": "MB3515", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3516@3": { + "A": "0", + "B": "MB3516", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181149.5, + 437827.4 + ], + "IO": "MB3516", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3516@2": { + "A": "0", + "B": "MB3516", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181149.5, + 287827.4 + ], + "IO": "MB3516", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3480@3": { + "A": "0", + "B": "MB3480", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187132.0, + 437141.7 + ], + "IO": "MB3480", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3480@2": { + "A": "0", + "B": "MB3480", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187132.0, + 287141.7 + ], + "IO": "MB3480", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1205)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3484@3": { + "A": "0", + "B": "MB3484", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187127.8, + 436549.5 + ], + "IO": "MB3484", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3484@2": { + "A": "0", + "B": "MB3484", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187127.8, + 286549.5 + ], + "IO": "MB3484", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1205)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3524@3": { + "A": "0", + "B": "MB3524", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175153.1, + 437804.8 + ], + "IO": "MB3524", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3524@2": { + "A": "0", + "B": "MB3524", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175153.1, + 287804.8 + ], + "IO": "MB3524", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3523@3": { + "A": "0", + "B": "MB3523", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175953.1, + 437804.8 + ], + "IO": "MB3523", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3523@2": { + "A": "0", + "B": "MB3523", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175953.1, + 287804.8 + ], + "IO": "MB3523", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3522@3": { + "A": "0", + "B": "MB3522", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176751.8, + 437802.8 + ], + "IO": "MB3522", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3522@2": { + "A": "0", + "B": "MB3522", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176751.8, + 287802.8 + ], + "IO": "MB3522", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3521@3": { + "A": "0", + "B": "MB3521", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177538.8, + 437804.8 + ], + "IO": "MB3521", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3521@2": { + "A": "0", + "B": "MB3521", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177538.8, + 287804.8 + ], + "IO": "MB3521", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3520@3": { + "A": "0", + "B": "MB3520", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178351.8, + 437802.8 + ], + "IO": "MB3520", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3520@2": { + "A": "0", + "B": "MB3520", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178351.8, + 287802.8 + ], + "IO": "MB3520", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3517@3": { + "A": "0", + "B": "MB3517", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179151.8, + 437802.8 + ], + "IO": "MB3517", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC0305-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3517@2": { + "A": "0", + "B": "MB3517", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179151.8, + 287802.8 + ], + "IO": "MB3517", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3540@3": { + "A": "0", + "B": "MB3540", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204368.7, + 437141.7 + ], + "IO": "MB3540", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3540@2": { + "A": "0", + "B": "MB3540", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204368.7, + 287141.7 + ], + "IO": "MB3540", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1206)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3544@3": { + "A": "0", + "B": "MB3544", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204364.4, + 436549.5 + ], + "IO": "MB3544", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3544@2": { + "A": "0", + "B": "MB3544", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204364.4, + 286549.5 + ], + "IO": "MB3544", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1206)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3570@3": { + "A": "0", + "B": "MB3570", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.8, + 437810.4 + ], + "IO": "MB3570", + "ID": "MB3570", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3570@2": { + "A": "0", + "B": "MB3570", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.8, + 287810.4 + ], + "IO": "MB3570", + "ID": "MB3570", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3571@3": { + "A": "0", + "B": "MB3571", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.7, + 437810.4 + ], + "IO": "MB3571", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3571@2": { + "A": "0", + "B": "MB3571", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.7, + 287810.4 + ], + "IO": "MB3571", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3572@3": { + "A": "0", + "B": "MB3572", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 437810.4 + ], + "IO": "MB3572", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3572@2": { + "A": "0", + "B": "MB3572", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 287810.4 + ], + "IO": "MB3572", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3573@3": { + "A": "0", + "B": "MB3573", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.7, + 437802.8 + ], + "IO": "MB3573", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3573@2": { + "A": "0", + "B": "MB3573", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.7, + 287802.8 + ], + "IO": "MB3573", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3574@3": { + "A": "0", + "B": "MB3574", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.7, + 437802.8 + ], + "IO": "MB3574", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3574@2": { + "A": "0", + "B": "MB3574", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.7, + 287802.8 + ], + "IO": "MB3574", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3575@3": { + "A": "0", + "B": "MB3575", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.7, + 437802.8 + ], + "IO": "MB3575", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3575@2": { + "A": "0", + "B": "MB3575", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.7, + 287802.8 + ], + "IO": "MB3575", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3576@3": { + "A": "0", + "B": "MB3576", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.7, + 437802.8 + ], + "IO": "MB3576", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3576@2": { + "A": "0", + "B": "MB3576", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.7, + 287802.8 + ], + "IO": "MB3576", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3577@3": { + "A": "0", + "B": "MB3577", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.9, + 437802.8 + ], + "IO": "MB3577", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3577@2": { + "A": "0", + "B": "MB3577", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197100.9, + 287802.8 + ], + "IO": "MB3577", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3584@3": { + "A": "0", + "B": "MB3584", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193103.3, + 437804.8 + ], + "IO": "MB3584", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3584@2": { + "A": "0", + "B": "MB3584", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193103.3, + 287804.8 + ], + "IO": "MB3584", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3583@3": { + "A": "0", + "B": "MB3583", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193903.3, + 437804.8 + ], + "IO": "MB3583", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3583@2": { + "A": "0", + "B": "MB3583", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193903.3, + 287804.8 + ], + "IO": "MB3583", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3582@3": { + "A": "0", + "B": "MB3582", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194702.0, + 437802.8 + ], + "IO": "MB3582", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3582@2": { + "A": "0", + "B": "MB3582", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194702.0, + 287802.8 + ], + "IO": "MB3582", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3581@3": { + "A": "0", + "B": "MB3581", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195489.0, + 437804.8 + ], + "IO": "MB3581", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3581@2": { + "A": "0", + "B": "MB3581", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195489.0, + 287804.8 + ], + "IO": "MB3581", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3580@3": { + "A": "0", + "B": "MB3580", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196302.0, + 437802.8 + ], + "IO": "MB3580", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3580@2": { + "A": "0", + "B": "MB3580", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196302.0, + 287802.8 + ], + "IO": "MB3580", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3585@3": { + "A": "0", + "B": "MB3585", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191307.5, + 437818.9 + ], + "IO": "MB3585", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3585@2": { + "A": "0", + "B": "MB3585", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191307.5, + 287818.9 + ], + "IO": "MB3585", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3586@3": { + "A": "0", + "B": "MB3586", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190507.5, + 437818.9 + ], + "IO": "MB3586", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3586@2": { + "A": "0", + "B": "MB3586", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190507.5, + 287818.9 + ], + "IO": "MB3586", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3587@3": { + "A": "0", + "B": "MB3587", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189729.9, + 437818.9 + ], + "IO": "MB3587", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3587@2": { + "A": "0", + "B": "MB3587", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189729.9, + 287818.9 + ], + "IO": "MB3587", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3590@3": { + "A": "0", + "B": "MB3590", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188955.7, + 437818.9 + ], + "IO": "MB3590", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3590@2": { + "A": "0", + "B": "MB3590", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188955.7, + 287818.9 + ], + "IO": "MB3590", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3630@3": { + "A": "0", + "B": "MB3630", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208060.3, + 437833.0 + ], + "IO": "MB3630", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3630@2": { + "A": "0", + "B": "MB3630", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208060.3, + 287833.0 + ], + "IO": "MB3630", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3631@3": { + "A": "0", + "B": "MB3631", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208838.5, + 437830.1 + ], + "IO": "MB3631", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3631@2": { + "A": "0", + "B": "MB3631", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208838.5, + 287830.1 + ], + "IO": "MB3631", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3632@3": { + "A": "0", + "B": "MB3632", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209638.5, + 437830.1 + ], + "IO": "MB3632", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3632@2": { + "A": "0", + "B": "MB3632", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209638.5, + 287830.1 + ], + "IO": "MB3632", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3633@3": { + "A": "0", + "B": "MB3633", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210613.2, + 437830.1 + ], + "IO": "MB3633", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3633@2": { + "A": "0", + "B": "MB3633", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210613.2, + 287830.1 + ], + "IO": "MB3633", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3634@3": { + "A": "0", + "B": "MB3634", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211473.2, + 437830.1 + ], + "IO": "MB3634", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3634@2": { + "A": "0", + "B": "MB3634", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211473.2, + 287830.1 + ], + "IO": "MB3634", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3635@3": { + "A": "0", + "B": "MB3635", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212273.2, + 437830.2 + ], + "IO": "MB3635", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3635@2": { + "A": "0", + "B": "MB3635", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212273.2, + 287830.2 + ], + "IO": "MB3635", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3636@3": { + "A": "0", + "B": "MB3636", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213072.3, + 437830.1 + ], + "IO": "MB3636", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3636@2": { + "A": "0", + "B": "MB3636", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213072.3, + 287830.1 + ], + "IO": "MB3636", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3637@3": { + "A": "0", + "B": "MB3637", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213843.2, + 437830.1 + ], + "IO": "MB3637", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3637@2": { + "A": "0", + "B": "MB3637", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213843.2, + 287830.1 + ], + "IO": "MB3637", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3640@3": { + "A": "0", + "B": "MB3640", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214673.2, + 437830.1 + ], + "IO": "MB3640", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3640@2": { + "A": "0", + "B": "MB3640", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214673.2, + 287830.1 + ], + "IO": "MB3640", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3641@3": { + "A": "0", + "B": "MB3641", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216418.4, + 437830.1 + ], + "IO": "MB3641", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3641@2": { + "A": "0", + "B": "MB3641", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216418.4, + 287830.1 + ], + "IO": "MB3641", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3642@3": { + "A": "0", + "B": "MB3642", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217218.4, + 437830.1 + ], + "IO": "MB3642", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3642@2": { + "A": "0", + "B": "MB3642", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217218.4, + 287830.1 + ], + "IO": "MB3642", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3643@3": { + "A": "0", + "B": "MB3643", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218018.4, + 437830.0 + ], + "IO": "MB3643", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3643@2": { + "A": "0", + "B": "MB3643", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218018.4, + 287830.0 + ], + "IO": "MB3643", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3644@3": { + "A": "0", + "B": "MB3644", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218817.6, + 437830.0 + ], + "IO": "MB3644", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3644@2": { + "A": "0", + "B": "MB3644", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218817.6, + 287830.0 + ], + "IO": "MB3644", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3645@3": { + "A": "0", + "B": "MB3645", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219618.4, + 437830.0 + ], + "IO": "MB3645", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3645@2": { + "A": "0", + "B": "MB3645", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219618.4, + 287830.0 + ], + "IO": "MB3645", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3646@3": { + "A": "0", + "B": "MB3646", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220418.4, + 437830.1 + ], + "IO": "MB3646", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3646@2": { + "A": "0", + "B": "MB3646", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220418.4, + 287830.1 + ], + "IO": "MB3646", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3647@3": { + "A": "0", + "B": "MB3647", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221218.4, + 437830.0 + ], + "IO": "MB3647", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3647@2": { + "A": "0", + "B": "MB3647", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221218.4, + 287830.0 + ], + "IO": "MB3647", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3650@3": { + "A": "0", + "B": "MB3650", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222418.4, + 437830.1 + ], + "IO": "MB3650", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3650@2": { + "A": "0", + "B": "MB3650", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222418.4, + 287830.1 + ], + "IO": "MB3650", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3651@3": { + "A": "0", + "B": "MB3651", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223218.4, + 437830.1 + ], + "IO": "MB3651", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.18 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3651@2": { + "A": "0", + "B": "MB3651", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223218.4, + 287830.1 + ], + "IO": "MB3651", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.18 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3652@3": { + "A": "0", + "B": "MB3652", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224018.4, + 437830.1 + ], + "IO": "MB3652", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.19 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3652@2": { + "A": "0", + "B": "MB3652", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224018.4, + 287830.1 + ], + "IO": "MB3652", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.19 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3653@3": { + "A": "0", + "B": "MB3653", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224818.4, + 437830.1 + ], + "IO": "MB3653", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.20 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3653@2": { + "A": "0", + "B": "MB3653", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224818.4, + 287830.1 + ], + "IO": "MB3653", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.20 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3654@3": { + "A": "0", + "B": "MB3654", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225618.4, + 437830.1 + ], + "IO": "MB3654", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.21 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3654@2": { + "A": "0", + "B": "MB3654", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225618.4, + 287830.1 + ], + "IO": "MB3654", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.21 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3617@3": { + "A": "0", + "B": "MB3617", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208458.9, + 438719.1 + ], + "IO": "MB3617", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3617@2": { + "A": "0", + "B": "MB3617", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207474.9, + 289020.0 + ], + "IO": "MB3617", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3600@3": { + "A": "0", + "B": "MB3600", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207428.1, + 436998.5 + ], + "IO": "MB3600", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3600@2": { + "A": "0", + "B": "MB3600", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207428.1, + 286998.5 + ], + "IO": "MB3600", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3604@3": { + "A": "0", + "B": "MB3604", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206614.7, + 436433.2 + ], + "IO": "MB3604", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3604@2": { + "A": "0", + "B": "MB3604", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206614.7, + 286433.2 + ], + "IO": "MB3604", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1207)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3660@3": { + "A": "0", + "B": "MB3660", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227619.6, + 437120.7 + ], + "IO": "MB3660", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3660@2": { + "A": "0", + "B": "MB3660", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227619.6, + 287120.7 + ], + "IO": "MB3660", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1208)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3664@3": { + "A": "0", + "B": "MB3664", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227614.7, + 436538.5 + ], + "IO": "MB3664", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3664@2": { + "A": "0", + "B": "MB3664", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227614.7, + 286538.5 + ], + "IO": "MB3664", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1208)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3690@3": { + "A": "0", + "B": "MB3690", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228810.3, + 437832.0 + ], + "IO": "MB3690", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3690@2": { + "A": "0", + "B": "MB3690", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228810.3, + 287832.0 + ], + "IO": "MB3690", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3691@3": { + "A": "0", + "B": "MB3691", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229588.5, + 437829.2 + ], + "IO": "MB3691", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3691@2": { + "A": "0", + "B": "MB3691", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229588.5, + 287829.1 + ], + "IO": "MB3691", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3692@3": { + "A": "0", + "B": "MB3692", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230388.5, + 437829.2 + ], + "IO": "MB3692", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3692@2": { + "A": "0", + "B": "MB3692", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230388.5, + 287829.1 + ], + "IO": "MB3692", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3693@3": { + "A": "0", + "B": "MB3693", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231151.6, + 437829.2 + ], + "IO": "MB3693", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3693@2": { + "A": "0", + "B": "MB3693", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231151.6, + 287829.1 + ], + "IO": "MB3693", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3694@3": { + "A": "0", + "B": "MB3694", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231995.1, + 437829.2 + ], + "IO": "MB3694", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3694@2": { + "A": "0", + "B": "MB3694", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231995.1, + 287829.1 + ], + "IO": "MB3694", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3695@3": { + "A": "0", + "B": "MB3695", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232795.1, + 437829.2 + ], + "IO": "MB3695", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3695@2": { + "A": "0", + "B": "MB3695", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232795.1, + 287829.2 + ], + "IO": "MB3695", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3696@3": { + "A": "0", + "B": "MB3696", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233594.2, + 437829.2 + ], + "IO": "MB3696", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3696@2": { + "A": "0", + "B": "MB3696", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233594.2, + 287829.2 + ], + "IO": "MB3696", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3697@3": { + "A": "0", + "B": "MB3697", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234481.8, + 437829.2 + ], + "IO": "MB3697", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3697@2": { + "A": "0", + "B": "MB3697", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234481.8, + 287829.1 + ], + "IO": "MB3697", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3700@3": { + "A": "0", + "B": "MB3700", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235311.8, + 437829.2 + ], + "IO": "MB3700", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3700@2": { + "A": "0", + "B": "MB3700", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235311.8, + 287829.1 + ], + "IO": "MB3700", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3701@3": { + "A": "0", + "B": "MB3701", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236140.0, + 437829.2 + ], + "IO": "MB3701", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3701@2": { + "A": "0", + "B": "MB3701", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236140.0, + 287829.1 + ], + "IO": "MB3701", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3702@3": { + "A": "0", + "B": "MB3702", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236940.0, + 437829.2 + ], + "IO": "MB3702", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3702@2": { + "A": "0", + "B": "MB3702", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236940.0, + 287829.1 + ], + "IO": "MB3702", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3703@3": { + "A": "0", + "B": "MB3703", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237740.0, + 437829.1 + ], + "IO": "MB3703", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3703@2": { + "A": "0", + "B": "MB3703", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237740.0, + 287829.1 + ], + "IO": "MB3703", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3704@3": { + "A": "0", + "B": "MB3704", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238539.2, + 437829.1 + ], + "IO": "MB3704", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3704@2": { + "A": "0", + "B": "MB3704", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238539.2, + 287829.1 + ], + "IO": "MB3704", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC0208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3724@3": { + "A": "0", + "B": "MB3724", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187300.2, + 423449.4 + ], + "IO": "MB3724", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M2205 Block 2.2.1) ", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3724@2": { + "A": "0", + "B": "MB3724", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187300.2, + 273386.7 + ], + "IO": "MB3724", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1205) ", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3720@3": { + "A": "0", + "B": "MB3720", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186664.6, + 421834.7 + ], + "IO": "MB3720", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3720@2": { + "A": "0", + "B": "MB3720", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186664.6, + 271834.7 + ], + "IO": "MB3720", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3763@3": { + "A": "0", + "B": "MB3763", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 423437.6 + ], + "IO": "MB3763", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3763@2": { + "A": "0", + "B": "MB3763", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 273437.6 + ], + "IO": "MB3763", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3762@3": { + "A": "0", + "B": "MB3762", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 423437.6 + ], + "IO": "MB3762", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3762@2": { + "A": "0", + "B": "MB3762", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 273437.6 + ], + "IO": "MB3762", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3761@3": { + "A": "0", + "B": "MB3761", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 423437.6 + ], + "IO": "MB3761", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3761@2": { + "A": "0", + "B": "MB3761", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 273437.6 + ], + "IO": "MB3761", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3760@3": { + "A": "0", + "B": "MB3760", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 423437.6 + ], + "IO": "MB3760", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3760@2": { + "A": "0", + "B": "MB3760", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 273437.6 + ], + "IO": "MB3760", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3757@3": { + "A": "0", + "B": "MB3757", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 423437.6 + ], + "IO": "MB3757", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3757@2": { + "A": "0", + "B": "MB3757", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 273437.6 + ], + "IO": "MB3757", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3764@3": { + "A": "0", + "B": "MB3764", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 423437.6 + ], + "IO": "MB3764", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3764@2": { + "A": "0", + "B": "MB3764", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 273437.6 + ], + "IO": "MB3764", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3756@3": { + "A": "0", + "B": "MB3756", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 423437.6 + ], + "IO": "MB3756", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3756@2": { + "A": "0", + "B": "MB3756", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 273437.6 + ], + "IO": "MB3756", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3755@3": { + "A": "0", + "B": "MB3755", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 423437.6 + ], + "IO": "MB3755", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3755@2": { + "A": "0", + "B": "MB3755", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 273437.6 + ], + "IO": "MB3755", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3754@3": { + "A": "0", + "B": "MB3754", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 423437.6 + ], + "IO": "MB3754", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3754@2": { + "A": "0", + "B": "MB3754", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 273437.6 + ], + "IO": "MB3754", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3753@3": { + "A": "0", + "B": "MB3753", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 423437.6 + ], + "IO": "MB3753", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3753@2": { + "A": "0", + "B": "MB3753", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 273437.6 + ], + "IO": "MB3753", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3752@3": { + "A": "0", + "B": "MB3752", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 423437.6 + ], + "IO": "MB3752", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3752@2": { + "A": "0", + "B": "MB3752", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 273437.6 + ], + "IO": "MB3752", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3751@3": { + "A": "0", + "B": "MB3751", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 423437.6 + ], + "IO": "MB3751", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3751@2": { + "A": "0", + "B": "MB3751", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 273437.6 + ], + "IO": "MB3751", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3750@3": { + "A": "0", + "B": "MB3750", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 423437.6 + ], + "IO": "MB3750", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3750@2": { + "A": "0", + "B": "MB3750", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 273437.6 + ], + "IO": "MB3750", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3721@3": { + "A": "0", + "B": "MB3721", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187189.0, + 422533.0 + ], + "IO": "MB3721", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M2205 Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3721@2": { + "A": "0", + "B": "MB3721", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187189.0, + 272533.0 + ], + "IO": "MB3721", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1205)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3784@3": { + "A": "0", + "B": "MB3784", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204390.8, + 423390.2 + ], + "IO": "MB3784", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2206) ", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3784@2": { + "A": "0", + "B": "MB3784", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204502.1, + 273384.4 + ], + "IO": "MB3784", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1206) ", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3780@3": { + "A": "0", + "B": "MB3780", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203432.0, + 421858.4 + ], + "IO": "MB3780", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3780@2": { + "A": "0", + "B": "MB3780", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203432.0, + 271858.4 + ], + "IO": "MB3780", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3781@3": { + "A": "0", + "B": "MB3781", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204390.9, + 422533.1 + ], + "IO": "MB3781", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M2206 Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3781@2": { + "A": "0", + "B": "MB3781", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204390.9, + 272533.1 + ], + "IO": "MB3781", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1206)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3816@3": { + "A": "0", + "B": "MB3816", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197951.9, + 423437.8 + ], + "IO": "MB3816", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3816@2": { + "A": "0", + "B": "MB3816", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197951.9, + 273437.8 + ], + "IO": "MB3816", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3815@3": { + "A": "0", + "B": "MB3815", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199151.9, + 423437.8 + ], + "IO": "MB3815", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3815@2": { + "A": "0", + "B": "MB3815", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199151.9, + 273437.8 + ], + "IO": "MB3815", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3814@3": { + "A": "0", + "B": "MB3814", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199951.9, + 423437.8 + ], + "IO": "MB3814", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3814@2": { + "A": "0", + "B": "MB3814", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199951.9, + 273437.8 + ], + "IO": "MB3814", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3813@3": { + "A": "0", + "B": "MB3813", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200751.9, + 423437.8 + ], + "IO": "MB3813", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3813@2": { + "A": "0", + "B": "MB3813", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200751.9, + 273437.8 + ], + "IO": "MB3813", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3812@3": { + "A": "0", + "B": "MB3812", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201551.9, + 423437.8 + ], + "IO": "MB3812", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3812@2": { + "A": "0", + "B": "MB3812", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201551.9, + 273437.8 + ], + "IO": "MB3812", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3811@3": { + "A": "0", + "B": "MB3811", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202351.9, + 423437.8 + ], + "IO": "MB3811", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3811@2": { + "A": "0", + "B": "MB3811", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202351.9, + 273437.8 + ], + "IO": "MB3811", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3810@3": { + "A": "0", + "B": "MB3810", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203151.9, + 423437.8 + ], + "IO": "MB3810", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3810@2": { + "A": "0", + "B": "MB3810", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203151.9, + 273437.8 + ], + "IO": "MB3810", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3823@3": { + "A": "0", + "B": "MB3823", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193901.9, + 423437.8 + ], + "IO": "MB3823", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3823@2": { + "A": "0", + "B": "MB3823", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193901.9, + 273437.8 + ], + "IO": "MB3823", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3822@3": { + "A": "0", + "B": "MB3822", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194701.9, + 423437.8 + ], + "IO": "MB3822", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3822@2": { + "A": "0", + "B": "MB3822", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194701.9, + 273437.8 + ], + "IO": "MB3822", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3821@3": { + "A": "0", + "B": "MB3821", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195501.9, + 423437.8 + ], + "IO": "MB3821", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3821@2": { + "A": "0", + "B": "MB3821", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195501.9, + 273437.8 + ], + "IO": "MB3821", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3820@3": { + "A": "0", + "B": "MB3820", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196301.9, + 423437.8 + ], + "IO": "MB3820", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3820@2": { + "A": "0", + "B": "MB3820", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196301.9, + 273437.8 + ], + "IO": "MB3820", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3817@3": { + "A": "0", + "B": "MB3817", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197101.9, + 423437.8 + ], + "IO": "MB3817", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3817@2": { + "A": "0", + "B": "MB3817", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197101.9, + 273437.8 + ], + "IO": "MB3817", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3824@3": { + "A": "0", + "B": "MB3824", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193101.9, + 423437.8 + ], + "IO": "MB3824", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3824@2": { + "A": "0", + "B": "MB3824", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193101.9, + 273437.8 + ], + "IO": "MB3824", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3826@3": { + "A": "0", + "B": "MB3826", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190501.9, + 423437.8 + ], + "IO": "MB3826", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3826@2": { + "A": "0", + "B": "MB3826", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190501.9, + 273437.8 + ], + "IO": "MB3826", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3825@3": { + "A": "0", + "B": "MB3825", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191301.9, + 423437.8 + ], + "IO": "MB3825", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3825@2": { + "A": "0", + "B": "MB3825", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191301.9, + 273437.8 + ], + "IO": "MB3825", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3827@3": { + "A": "0", + "B": "MB3827", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189701.9, + 423437.8 + ], + "IO": "MB3827", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3827@2": { + "A": "0", + "B": "MB3827", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189701.9, + 273437.8 + ], + "IO": "MB3827", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3830@3": { + "A": "0", + "B": "MB3830", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188901.9, + 423437.8 + ], + "IO": "MB3830", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 2.2.2)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3830@2": { + "A": "0", + "B": "MB3830", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188901.9, + 273437.8 + ], + "IO": "MB3830", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 1.2.2)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3844@3": { + "A": "0", + "B": "MB3844", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206541.8, + 423372.3 + ], + "IO": "MB3844", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2207) ", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3844@2": { + "A": "0", + "B": "MB3844", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206541.8, + 273378.3 + ], + "IO": "MB3844", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1207) ", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3841@3": { + "A": "0", + "B": "MB3841", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206660.5, + 422531.6 + ], + "IO": "MB3841", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M2207 Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3841@2": { + "A": "0", + "B": "MB3841", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206660.5, + 272531.6 + ], + "IO": "MB3841", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1207 Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3840@3": { + "A": "0", + "B": "MB3840", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207906.0, + 421965.4 + ], + "IO": "MB3840", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3840@2": { + "A": "0", + "B": "MB3840", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207894.6, + 271965.4 + ], + "IO": "MB3840", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3870@3": { + "A": "0", + "B": "MB3870", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208401.5, + 423436.2 + ], + "IO": "MB3870", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3870@2": { + "A": "0", + "B": "MB3870", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208401.5, + 273436.2 + ], + "IO": "MB3870", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3871@3": { + "A": "0", + "B": "MB3871", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209201.5, + 423436.2 + ], + "IO": "MB3871", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3871@2": { + "A": "0", + "B": "MB3871", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209201.5, + 273436.2 + ], + "IO": "MB3871", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3872@3": { + "A": "0", + "B": "MB3872", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210001.5, + 423436.2 + ], + "IO": "MB3872", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3872@2": { + "A": "0", + "B": "MB3872", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210001.5, + 273436.2 + ], + "IO": "MB3872", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3873@3": { + "A": "0", + "B": "MB3873", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211151.5, + 423436.2 + ], + "IO": "MB3873", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3873@2": { + "A": "0", + "B": "MB3873", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211151.5, + 273436.2 + ], + "IO": "MB3873", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3874@3": { + "A": "0", + "B": "MB3874", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211951.5, + 423436.2 + ], + "IO": "MB3874", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3874@2": { + "A": "0", + "B": "MB3874", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211951.5, + 273436.2 + ], + "IO": "MB3874", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3875@3": { + "A": "0", + "B": "MB3875", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212751.5, + 423436.2 + ], + "IO": "MB3875", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3875@2": { + "A": "0", + "B": "MB3875", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212751.5, + 273436.2 + ], + "IO": "MB3875", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3876@3": { + "A": "0", + "B": "MB3876", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213551.5, + 423436.2 + ], + "IO": "MB3876", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3876@2": { + "A": "0", + "B": "MB3876", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213551.5, + 273436.2 + ], + "IO": "MB3876", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3877@3": { + "A": "0", + "B": "MB3877", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214351.5, + 423436.2 + ], + "IO": "MB3877", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3877@2": { + "A": "0", + "B": "MB3877", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214351.5, + 273436.2 + ], + "IO": "MB3877", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3880@3": { + "A": "0", + "B": "MB3880", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215151.5, + 423436.2 + ], + "IO": "MB3880", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3880@2": { + "A": "0", + "B": "MB3880", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215151.5, + 273436.2 + ], + "IO": "MB3880", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3881@3": { + "A": "0", + "B": "MB3881", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217151.5, + 423436.2 + ], + "IO": "MB3881", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3881@2": { + "A": "0", + "B": "MB3881", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217151.5, + 273436.2 + ], + "IO": "MB3881", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3882@3": { + "A": "0", + "B": "MB3882", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217951.5, + 423436.2 + ], + "IO": "MB3882", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3882@2": { + "A": "0", + "B": "MB3882", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217951.5, + 273436.2 + ], + "IO": "MB3882", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3883@3": { + "A": "0", + "B": "MB3883", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218751.5, + 423436.2 + ], + "IO": "MB3883", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3883@2": { + "A": "0", + "B": "MB3883", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218751.5, + 273436.2 + ], + "IO": "MB3883", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3884@3": { + "A": "0", + "B": "MB3884", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219551.5, + 423436.2 + ], + "IO": "MB3884", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3884@2": { + "A": "0", + "B": "MB3884", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219551.5, + 273436.2 + ], + "IO": "MB3884", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3885@3": { + "A": "0", + "B": "MB3885", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220351.5, + 423436.2 + ], + "IO": "MB3885", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3885@2": { + "A": "0", + "B": "MB3885", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220351.5, + 273436.2 + ], + "IO": "MB3885", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3886@3": { + "A": "0", + "B": "MB3886", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221151.5, + 423436.2 + ], + "IO": "MB3886", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3886@2": { + "A": "0", + "B": "MB3886", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221151.5, + 273436.2 + ], + "IO": "MB3886", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3887@3": { + "A": "0", + "B": "MB3887", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221951.5, + 423436.2 + ], + "IO": "MB3887", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3887@2": { + "A": "0", + "B": "MB3887", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221951.5, + 273436.2 + ], + "IO": "MB3887", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3890@3": { + "A": "0", + "B": "MB3890", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223151.5, + 423436.2 + ], + "IO": "MB3890", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3890@2": { + "A": "0", + "B": "MB3890", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223151.5, + 273436.2 + ], + "IO": "MB3890", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3891@3": { + "A": "0", + "B": "MB3891", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223951.5, + 423436.2 + ], + "IO": "MB3891", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 18 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3891@2": { + "A": "0", + "B": "MB3891", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223951.5, + 273436.2 + ], + "IO": "MB3891", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 18 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3892@3": { + "A": "0", + "B": "MB3892", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224751.5, + 423436.2 + ], + "IO": "MB3892", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 19 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3892@2": { + "A": "0", + "B": "MB3892", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224751.5, + 273436.2 + ], + "IO": "MB3892", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 19 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3893@3": { + "A": "0", + "B": "MB3893", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225551.5, + 423436.2 + ], + "IO": "MB3893", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 20 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3893@2": { + "A": "0", + "B": "MB3893", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225551.5, + 273436.2 + ], + "IO": "MB3893", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 20 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3894@3": { + "A": "0", + "B": "MB3894", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226351.5, + 423436.2 + ], + "IO": "MB3894", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 21 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3894@2": { + "A": "0", + "B": "MB3894", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226351.5, + 273436.2 + ], + "IO": "MB3894", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 21 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3904@3": { + "A": "0", + "B": "MB3904", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 423393.6 + ], + "IO": "MB3904", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2208)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3904@2": { + "A": "0", + "B": "MB3904", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 273381.8 + ], + "IO": "MB3904", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1208) ", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3901@3": { + "A": "0", + "B": "MB3901", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.8, + 422533.0 + ], + "IO": "MB3901", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M2208)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3901@2": { + "A": "0", + "B": "MB3901", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.8, + 272533.0 + ], + "IO": "MB3901", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M1208)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3900@3": { + "A": "0", + "B": "MB3900", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228310.7, + 421983.4 + ], + "IO": "MB3900", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-KR M2204)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3900@2": { + "A": "0", + "B": "MB3900", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228307.3, + 271899.6 + ], + "IO": "MB3900", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3905@3": { + "A": "0", + "B": "MB3905", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238013.9, + 421904.0 + ], + "IO": "MB3905", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3905@2": { + "A": "0", + "B": "MB3905", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227178.5, + 270789.9 + ], + "IO": "MB3905", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3930@3": { + "A": "0", + "B": "MB3930", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 423437.6 + ], + "IO": "MB3930", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3930@2": { + "A": "0", + "B": "MB3930", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229150.0, + 273437.6 + ], + "IO": "MB3930", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3931@3": { + "A": "0", + "B": "MB3931", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 423437.6 + ], + "IO": "MB3931", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3931@2": { + "A": "0", + "B": "MB3931", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229950.0, + 273437.6 + ], + "IO": "MB3931", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3932@3": { + "A": "0", + "B": "MB3932", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 423437.6 + ], + "IO": "MB3932", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3932@2": { + "A": "0", + "B": "MB3932", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230750.0, + 273437.6 + ], + "IO": "MB3932", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3933@3": { + "A": "0", + "B": "MB3933", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 423437.6 + ], + "IO": "MB3933", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3933@2": { + "A": "0", + "B": "MB3933", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 273437.6 + ], + "IO": "MB3933", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3934@3": { + "A": "0", + "B": "MB3934", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 423437.6 + ], + "IO": "MB3934", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3934@2": { + "A": "0", + "B": "MB3934", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 273437.6 + ], + "IO": "MB3934", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3935@3": { + "A": "0", + "B": "MB3935", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 423437.6 + ], + "IO": "MB3935", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3935@2": { + "A": "0", + "B": "MB3935", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 273437.6 + ], + "IO": "MB3935", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3936@3": { + "A": "0", + "B": "MB3936", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 423437.6 + ], + "IO": "MB3936", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3936@2": { + "A": "0", + "B": "MB3936", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 273437.6 + ], + "IO": "MB3936", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3937@3": { + "A": "0", + "B": "MB3937", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 423437.6 + ], + "IO": "MB3937", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3937@2": { + "A": "0", + "B": "MB3937", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 273437.6 + ], + "IO": "MB3937", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3940@3": { + "A": "0", + "B": "MB3940", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 423437.6 + ], + "IO": "MB3940", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3940@2": { + "A": "0", + "B": "MB3940", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 273437.6 + ], + "IO": "MB3940", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3941@3": { + "A": "0", + "B": "MB3941", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 423437.6 + ], + "IO": "MB3941", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3941@2": { + "A": "0", + "B": "MB3941", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236750.0, + 273437.6 + ], + "IO": "MB3941", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3942@3": { + "A": "0", + "B": "MB3942", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 423437.6 + ], + "IO": "MB3942", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3942@2": { + "A": "0", + "B": "MB3942", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237550.0, + 273437.6 + ], + "IO": "MB3942", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3943@3": { + "A": "0", + "B": "MB3943", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 423437.6 + ], + "IO": "MB3943", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3943@2": { + "A": "0", + "B": "MB3943", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238350.0, + 273437.6 + ], + "IO": "MB3943", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3944@3": { + "A": "0", + "B": "MB3944", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239150.0, + 423437.6 + ], + "IO": "MB3944", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3944@2": { + "A": "0", + "B": "MB3944", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239150.0, + 273437.6 + ], + "IO": "MB3944", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4012@3": { + "A": "0", + "B": "MB4012", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 416311.9 + ], + "IO": "MB4012", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 19 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4012@2": { + "A": "0", + "B": "MB4012", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 266311.9 + ], + "IO": "MB4012", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 19 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4003@3": { + "A": "0", + "B": "MB4003", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 416311.9 + ], + "IO": "MB4003", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4003@2": { + "A": "0", + "B": "MB4003", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175949.9, + 266311.9 + ], + "IO": "MB4003", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4002@3": { + "A": "0", + "B": "MB4002", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 416311.9 + ], + "IO": "MB4002", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4002@2": { + "A": "0", + "B": "MB4002", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176749.9, + 266311.9 + ], + "IO": "MB4002", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4001@3": { + "A": "0", + "B": "MB4001", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 416311.9 + ], + "IO": "MB4001", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4001@2": { + "A": "0", + "B": "MB4001", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177549.9, + 266311.9 + ], + "IO": "MB4001", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4000@3": { + "A": "0", + "B": "MB4000", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 416311.9 + ], + "IO": "MB4000", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4000@2": { + "A": "0", + "B": "MB4000", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178349.9, + 266311.9 + ], + "IO": "MB4000", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3997@3": { + "A": "0", + "B": "MB3997", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 416311.9 + ], + "IO": "MB3997", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3997@2": { + "A": "0", + "B": "MB3997", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179149.9, + 266311.9 + ], + "IO": "MB3997", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4006@3": { + "A": "0", + "B": "MB4006", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 416311.9 + ], + "IO": "MB4006", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4006@2": { + "A": "0", + "B": "MB4006", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 266311.9 + ], + "IO": "MB4006", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4005@3": { + "A": "0", + "B": "MB4005", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 416311.9 + ], + "IO": "MB4005", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4005@2": { + "A": "0", + "B": "MB4005", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 266311.9 + ], + "IO": "MB4005", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4004@3": { + "A": "0", + "B": "MB4004", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 416311.9 + ], + "IO": "MB4004", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4004@2": { + "A": "0", + "B": "MB4004", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175149.9, + 266311.9 + ], + "IO": "MB4004", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4007@3": { + "A": "0", + "B": "MB4007", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 416311.9 + ], + "IO": "MB4007", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4007@2": { + "A": "0", + "B": "MB4007", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 266311.9 + ], + "IO": "MB4007", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4011@3": { + "A": "0", + "B": "MB4011", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 416311.9 + ], + "IO": "MB4011", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 18 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4011@2": { + "A": "0", + "B": "MB4011", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 266311.9 + ], + "IO": "MB4011", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 18 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4010@3": { + "A": "0", + "B": "MB4010", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 416311.9 + ], + "IO": "MB4010", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4010@2": { + "A": "0", + "B": "MB4010", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 266311.9 + ], + "IO": "MB4010", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3996@3": { + "A": "0", + "B": "MB3996", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 416311.9 + ], + "IO": "MB3996", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3996@2": { + "A": "0", + "B": "MB3996", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181150.0, + 266311.9 + ], + "IO": "MB3996", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3995@3": { + "A": "0", + "B": "MB3995", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 416311.9 + ], + "IO": "MB3995", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3995@2": { + "A": "0", + "B": "MB3995", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181950.0, + 266311.9 + ], + "IO": "MB3995", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3994@3": { + "A": "0", + "B": "MB3994", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 416311.9 + ], + "IO": "MB3994", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3994@2": { + "A": "0", + "B": "MB3994", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182750.0, + 266311.9 + ], + "IO": "MB3994", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3993@3": { + "A": "0", + "B": "MB3993", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 416311.9 + ], + "IO": "MB3993", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3993@2": { + "A": "0", + "B": "MB3993", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183550.0, + 266311.9 + ], + "IO": "MB3993", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3992@3": { + "A": "0", + "B": "MB3992", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 416311.9 + ], + "IO": "MB3992", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3992@2": { + "A": "0", + "B": "MB3992", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184350.0, + 266311.9 + ], + "IO": "MB3992", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3991@3": { + "A": "0", + "B": "MB3991", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 416311.9 + ], + "IO": "MB3991", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3991@2": { + "A": "0", + "B": "MB3991", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185150.0, + 266311.9 + ], + "IO": "MB3991", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3990@3": { + "A": "0", + "B": "MB3990", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 416311.9 + ], + "IO": "MB3990", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3990@2": { + "A": "0", + "B": "MB3990", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185950.0, + 266311.9 + ], + "IO": "MB3990", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3960@3": { + "A": "0", + "B": "MB3960", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186488.6, + 416927.2 + ], + "IO": "MB3960", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3960@2": { + "A": "0", + "B": "MB3960", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 186488.6, + 266927.2 + ], + "IO": "MB3960", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1305)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3961@3": { + "A": "0", + "B": "MB3961", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187189.0, + 417625.4 + ], + "IO": "MB3961", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M2305 Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3961@2": { + "A": "0", + "B": "MB3961", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187189.0, + 267625.4 + ], + "IO": "MB3961", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1305)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3964@3": { + "A": "0", + "B": "MB3964", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187179.7, + 416058.0 + ], + "IO": "MB3964", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2305) ", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3964@2": { + "A": "0", + "B": "MB3964", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187179.7, + 266050.8 + ], + "IO": "MB3964", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1305) ", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4056@3": { + "A": "0", + "B": "MB4056", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 416311.9 + ], + "IO": "MB4056", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4056@2": { + "A": "0", + "B": "MB4056", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197950.0, + 266311.9 + ], + "IO": "MB4056", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4055@3": { + "A": "0", + "B": "MB4055", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 416311.9 + ], + "IO": "MB4055", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4055@2": { + "A": "0", + "B": "MB4055", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199150.0, + 266311.9 + ], + "IO": "MB4055", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4054@3": { + "A": "0", + "B": "MB4054", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 416311.9 + ], + "IO": "MB4054", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4054@2": { + "A": "0", + "B": "MB4054", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199950.0, + 266311.9 + ], + "IO": "MB4054", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4053@3": { + "A": "0", + "B": "MB4053", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.0, + 416311.9 + ], + "IO": "MB4053", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4053@2": { + "A": "0", + "B": "MB4053", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200750.0, + 266311.9 + ], + "IO": "MB4053", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4052@3": { + "A": "0", + "B": "MB4052", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 416311.9 + ], + "IO": "MB4052", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4052@2": { + "A": "0", + "B": "MB4052", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201550.0, + 266311.9 + ], + "IO": "MB4052", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4051@3": { + "A": "0", + "B": "MB4051", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 416311.9 + ], + "IO": "MB4051", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4051@2": { + "A": "0", + "B": "MB4051", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202350.0, + 266311.9 + ], + "IO": "MB4051", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4050@3": { + "A": "0", + "B": "MB4050", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 416311.9 + ], + "IO": "MB4050", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4050@2": { + "A": "0", + "B": "MB4050", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203150.0, + 266311.9 + ], + "IO": "MB4050", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4020@3": { + "A": "0", + "B": "MB4020", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203688.6, + 416927.2 + ], + "IO": "MB4020", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4020@2": { + "A": "0", + "B": "MB4020", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203688.6, + 266927.2 + ], + "IO": "MB4020", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-KR M1301)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4021@3": { + "A": "0", + "B": "MB4021", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204040.3, + 417625.4 + ], + "IO": "MB4021", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M2306 Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4021@2": { + "A": "0", + "B": "MB4021", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204040.3, + 267625.4 + ], + "IO": "MB4021", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1306 Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4024@3": { + "A": "0", + "B": "MB4024", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204379.8, + 416059.7 + ], + "IO": "MB4024", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2206) ", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4024@2": { + "A": "0", + "B": "MB4024", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204379.8, + 266057.3 + ], + "IO": "MB4024", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1306 Block 1.3.2) ", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4063@3": { + "A": "0", + "B": "MB4063", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193949.9, + 416311.9 + ], + "IO": "MB4063", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4063@2": { + "A": "0", + "B": "MB4063", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193949.9, + 266311.9 + ], + "IO": "MB4063", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4062@3": { + "A": "0", + "B": "MB4062", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194749.9, + 416311.9 + ], + "IO": "MB4062", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4062@2": { + "A": "0", + "B": "MB4062", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194749.9, + 266311.9 + ], + "IO": "MB4062", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4061@3": { + "A": "0", + "B": "MB4061", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195549.9, + 416311.9 + ], + "IO": "MB4061", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4061@2": { + "A": "0", + "B": "MB4061", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195549.9, + 266311.9 + ], + "IO": "MB4061", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4060@3": { + "A": "0", + "B": "MB4060", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196349.9, + 416311.9 + ], + "IO": "MB4060", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4060@2": { + "A": "0", + "B": "MB4060", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196349.9, + 266311.9 + ], + "IO": "MB4060", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4057@3": { + "A": "0", + "B": "MB4057", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197149.9, + 416311.9 + ], + "IO": "MB4057", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4057@2": { + "A": "0", + "B": "MB4057", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197149.9, + 266311.9 + ], + "IO": "MB4057", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4064@3": { + "A": "0", + "B": "MB4064", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193149.9, + 416311.9 + ], + "IO": "MB4064", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4064@2": { + "A": "0", + "B": "MB4064", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193149.9, + 266311.9 + ], + "IO": "MB4064", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4066@3": { + "A": "0", + "B": "MB4066", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 416311.9 + ], + "IO": "MB4066", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4066@2": { + "A": "0", + "B": "MB4066", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190500.0, + 266311.9 + ], + "IO": "MB4066", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4065@3": { + "A": "0", + "B": "MB4065", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 416311.9 + ], + "IO": "MB4065", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4065@2": { + "A": "0", + "B": "MB4065", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191300.0, + 266311.9 + ], + "IO": "MB4065", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4067@3": { + "A": "0", + "B": "MB4067", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.0, + 416311.9 + ], + "IO": "MB4067", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4067@2": { + "A": "0", + "B": "MB4067", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189700.0, + 266311.9 + ], + "IO": "MB4067", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4070@3": { + "A": "0", + "B": "MB4070", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 416311.9 + ], + "IO": "MB4070", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4070@2": { + "A": "0", + "B": "MB4070", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188900.0, + 266311.9 + ], + "IO": "MB4070", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4084@3": { + "A": "0", + "B": "MB4084", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206548.3, + 416058.7 + ], + "IO": "MB4084", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M2308 Block 2.3.3) ", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4084@2": { + "A": "0", + "B": "MB4084", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206437.9, + 266058.4 + ], + "IO": "MB4084", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1307) ", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4080@3": { + "A": "0", + "B": "MB4080", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207201.6, + 416927.2 + ], + "IO": "MB4080", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4080@2": { + "A": "0", + "B": "MB4080", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207201.6, + 266927.2 + ], + "IO": "MB4080", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1302)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4081@3": { + "A": "0", + "B": "MB4081", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206641.6, + 417625.4 + ], + "IO": "MB4081", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M2308 Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4081@2": { + "A": "0", + "B": "MB4081", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206641.6, + 267625.4 + ], + "IO": "MB4081", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1307 Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4110@3": { + "A": "0", + "B": "MB4110", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208401.5, + 416323.7 + ], + "IO": "MB4110", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4110@2": { + "A": "0", + "B": "MB4110", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208401.5, + 266323.7 + ], + "IO": "MB4110", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4111@3": { + "A": "0", + "B": "MB4111", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209201.5, + 416323.7 + ], + "IO": "MB4111", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4111@2": { + "A": "0", + "B": "MB4111", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209201.5, + 266323.7 + ], + "IO": "MB4111", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4112@3": { + "A": "0", + "B": "MB4112", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210001.5, + 416323.7 + ], + "IO": "MB4112", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4112@2": { + "A": "0", + "B": "MB4112", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210001.5, + 266323.7 + ], + "IO": "MB4112", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4113@3": { + "A": "0", + "B": "MB4113", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211151.5, + 416323.7 + ], + "IO": "MB4113", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4113@2": { + "A": "0", + "B": "MB4113", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211151.5, + 266323.7 + ], + "IO": "MB4113", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4114@3": { + "A": "0", + "B": "MB4114", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211951.5, + 416323.7 + ], + "IO": "MB4114", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4114@2": { + "A": "0", + "B": "MB4114", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211951.5, + 266323.7 + ], + "IO": "MB4114", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4115@3": { + "A": "0", + "B": "MB4115", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212751.5, + 416323.7 + ], + "IO": "MB4115", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4115@2": { + "A": "0", + "B": "MB4115", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212751.5, + 266323.7 + ], + "IO": "MB4115", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4116@3": { + "A": "0", + "B": "MB4116", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213551.5, + 416323.7 + ], + "IO": "MB4116", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4116@2": { + "A": "0", + "B": "MB4116", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213551.5, + 266323.7 + ], + "IO": "MB4116", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4117@3": { + "A": "0", + "B": "MB4117", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214351.5, + 416323.7 + ], + "IO": "MB4117", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4117@2": { + "A": "0", + "B": "MB4117", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214351.5, + 266323.7 + ], + "IO": "MB4117", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4120@3": { + "A": "0", + "B": "MB4120", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215151.5, + 416323.7 + ], + "IO": "MB4120", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4120@2": { + "A": "0", + "B": "MB4120", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215151.5, + 266323.7 + ], + "IO": "MB4120", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4121@3": { + "A": "0", + "B": "MB4121", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217151.5, + 416323.7 + ], + "IO": "MB4121", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4121@2": { + "A": "0", + "B": "MB4121", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217151.5, + 266323.7 + ], + "IO": "MB4121", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4122@3": { + "A": "0", + "B": "MB4122", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217951.5, + 416323.7 + ], + "IO": "MB4122", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4122@2": { + "A": "0", + "B": "MB4122", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217951.5, + 266323.7 + ], + "IO": "MB4122", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4123@3": { + "A": "0", + "B": "MB4123", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218751.5, + 416323.7 + ], + "IO": "MB4123", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4123@2": { + "A": "0", + "B": "MB4123", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218751.5, + 266323.7 + ], + "IO": "MB4123", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4124@3": { + "A": "0", + "B": "MB4124", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219551.5, + 416323.7 + ], + "IO": "MB4124", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4124@2": { + "A": "0", + "B": "MB4124", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219551.5, + 266323.7 + ], + "IO": "MB4124", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4125@3": { + "A": "0", + "B": "MB4125", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220351.5, + 416323.7 + ], + "IO": "MB4125", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4125@2": { + "A": "0", + "B": "MB4125", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220351.5, + 266323.7 + ], + "IO": "MB4125", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4126@3": { + "A": "0", + "B": "MB4126", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221151.5, + 416323.7 + ], + "IO": "MB4126", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4126@2": { + "A": "0", + "B": "MB4126", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221151.5, + 266323.7 + ], + "IO": "MB4126", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4127@3": { + "A": "0", + "B": "MB4127", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221951.5, + 416323.7 + ], + "IO": "MB4127", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4127@2": { + "A": "0", + "B": "MB4127", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221951.5, + 266323.7 + ], + "IO": "MB4127", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4130@3": { + "A": "0", + "B": "MB4130", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223151.5, + 416323.7 + ], + "IO": "MB4130", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4130@2": { + "A": "0", + "B": "MB4130", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223151.5, + 266323.7 + ], + "IO": "MB4130", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4131@3": { + "A": "0", + "B": "MB4131", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223951.5, + 416323.7 + ], + "IO": "MB4131", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 18 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4131@2": { + "A": "0", + "B": "MB4131", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223951.5, + 266323.7 + ], + "IO": "MB4131", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 18 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4132@3": { + "A": "0", + "B": "MB4132", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224751.5, + 416323.7 + ], + "IO": "MB4132", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 19 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4132@2": { + "A": "0", + "B": "MB4132", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224751.5, + 266323.7 + ], + "IO": "MB4132", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 19 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4133@3": { + "A": "0", + "B": "MB4133", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225551.5, + 416323.7 + ], + "IO": "MB4133", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 20 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4133@2": { + "A": "0", + "B": "MB4133", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225551.5, + 266323.7 + ], + "IO": "MB4133", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 20 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4134@3": { + "A": "0", + "B": "MB4134", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226351.5, + 416323.7 + ], + "IO": "MB4134", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 21 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4134@2": { + "A": "0", + "B": "MB4134", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226351.5, + 266323.7 + ], + "IO": "MB4134", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 21 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4085@3": { + "A": "0", + "B": "MB4085", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225376.4, + 417799.0 + ], + "IO": "MB4085", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4085@2": { + "A": "0", + "B": "MB4085", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214411.0, + 268767.6 + ], + "IO": "MB4085", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (ILS-KR-M1302)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4144@3": { + "A": "0", + "B": "MB4144", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227438.0, + 416057.7 + ], + "IO": "MB4144", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2308)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4144@2": { + "A": "0", + "B": "MB4144", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227438.0, + 266056.5 + ], + "IO": "MB4144", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1308) ", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4140@3": { + "A": "0", + "B": "MB4140", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228201.6, + 416927.2 + ], + "IO": "MB4140", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4140@2": { + "A": "0", + "B": "MB4140", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228201.6, + 266927.2 + ], + "IO": "MB4140", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4141@3": { + "A": "0", + "B": "MB4141", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227641.7, + 417625.4 + ], + "IO": "MB4141", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M2308 Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4141@2": { + "A": "0", + "B": "MB4141", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227641.7, + 267625.4 + ], + "IO": "MB4141", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1308 Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4170@3": { + "A": "0", + "B": "MB4170", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229151.5, + 416323.7 + ], + "IO": "MB4170", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4170@2": { + "A": "0", + "B": "MB4170", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229151.5, + 266323.7 + ], + "IO": "MB4170", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4171@3": { + "A": "0", + "B": "MB4171", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229951.5, + 416323.7 + ], + "IO": "MB4171", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4171@2": { + "A": "0", + "B": "MB4171", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229951.5, + 266323.7 + ], + "IO": "MB4171", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4172@3": { + "A": "0", + "B": "MB4172", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230751.5, + 416323.7 + ], + "IO": "MB4172", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4172@2": { + "A": "0", + "B": "MB4172", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230751.5, + 266323.7 + ], + "IO": "MB4172", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4173@3": { + "A": "0", + "B": "MB4173", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 416323.7 + ], + "IO": "MB4173", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4173@2": { + "A": "0", + "B": "MB4173", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231550.0, + 266323.7 + ], + "IO": "MB4173", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4174@3": { + "A": "0", + "B": "MB4174", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 416323.7 + ], + "IO": "MB4174", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4174@2": { + "A": "0", + "B": "MB4174", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232350.0, + 266323.7 + ], + "IO": "MB4174", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4175@3": { + "A": "0", + "B": "MB4175", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 416323.7 + ], + "IO": "MB4175", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4175@2": { + "A": "0", + "B": "MB4175", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233150.0, + 266323.7 + ], + "IO": "MB4175", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 6 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4176@3": { + "A": "0", + "B": "MB4176", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 416323.7 + ], + "IO": "MB4176", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4176@2": { + "A": "0", + "B": "MB4176", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233950.0, + 266323.7 + ], + "IO": "MB4176", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 7 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4177@3": { + "A": "0", + "B": "MB4177", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 416323.7 + ], + "IO": "MB4177", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4177@2": { + "A": "0", + "B": "MB4177", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235150.0, + 266323.7 + ], + "IO": "MB4177", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 8 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4180@3": { + "A": "0", + "B": "MB4180", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 416323.7 + ], + "IO": "MB4180", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4180@2": { + "A": "0", + "B": "MB4180", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235950.0, + 266323.7 + ], + "IO": "MB4180", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 9 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4181@3": { + "A": "0", + "B": "MB4181", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236751.5, + 416323.7 + ], + "IO": "MB4181", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4181@2": { + "A": "0", + "B": "MB4181", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236751.5, + 266323.7 + ], + "IO": "MB4181", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 10 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4182@3": { + "A": "0", + "B": "MB4182", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237551.5, + 416323.7 + ], + "IO": "MB4182", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4182@2": { + "A": "0", + "B": "MB4182", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237551.5, + 266323.7 + ], + "IO": "MB4182", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 11 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4183@3": { + "A": "0", + "B": "MB4183", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238351.5, + 416323.7 + ], + "IO": "MB4183", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4183@2": { + "A": "0", + "B": "MB4183", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238351.5, + 266323.7 + ], + "IO": "MB4183", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 12 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4184@3": { + "A": "0", + "B": "MB4184", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239151.5, + 416323.7 + ], + "IO": "MB4184", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4184@2": { + "A": "0", + "B": "MB4184", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239151.5, + 266323.7 + ], + "IO": "MB4184", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 13 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4245@3": { + "A": "0", + "B": "MB4245", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174007.5, + 399156.1 + ], + "IO": "MB4245", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4245@2": { + "A": "0", + "B": "MB4245", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174007.5, + 249156.1 + ], + "IO": "MB4245", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4246@3": { + "A": "0", + "B": "MB4246", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173207.5, + 399156.1 + ], + "IO": "MB4246", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4246@2": { + "A": "0", + "B": "MB4246", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173207.5, + 249156.1 + ], + "IO": "MB4246", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4247@3": { + "A": "0", + "B": "MB4247", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172429.9, + 399156.1 + ], + "IO": "MB4247", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4247@2": { + "A": "0", + "B": "MB4247", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172429.9, + 249156.1 + ], + "IO": "MB4247", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4250@3": { + "A": "0", + "B": "MB4250", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171655.7, + 399156.1 + ], + "IO": "MB4250", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4250@2": { + "A": "0", + "B": "MB4250", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171655.7, + 249156.1 + ], + "IO": "MB4250", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4251@3": { + "A": "0", + "B": "MB4251", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170882.8, + 399156.1 + ], + "IO": "MB4251", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.18 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4251@2": { + "A": "0", + "B": "MB4251", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170882.8, + 249156.1 + ], + "IO": "MB4251", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.18 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4252@3": { + "A": "0", + "B": "MB4252", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170129.0, + 399156.1 + ], + "IO": "MB4252", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.19 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4252@2": { + "A": "0", + "B": "MB4252", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170129.0, + 249156.1 + ], + "IO": "MB4252", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.19 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4230@3": { + "A": "0", + "B": "MB4230", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185949.6, + 399161.6 + ], + "IO": "MB4230", + "ID": "MB4230", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4230@2": { + "A": "0", + "B": "MB4230", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185949.6, + 249161.6 + ], + "IO": "MB4230", + "ID": "MB4230", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4231@3": { + "A": "0", + "B": "MB4231", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185149.5, + 399161.6 + ], + "IO": "MB4231", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4231@2": { + "A": "0", + "B": "MB4231", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 185149.5, + 249161.6 + ], + "IO": "MB4231", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4232@3": { + "A": "0", + "B": "MB4232", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184348.7, + 399161.6 + ], + "IO": "MB4232", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4232@2": { + "A": "0", + "B": "MB4232", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 184348.7, + 249161.6 + ], + "IO": "MB4232", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4233@3": { + "A": "0", + "B": "MB4233", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183549.5, + 399154.0 + ], + "IO": "MB4233", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4233@2": { + "A": "0", + "B": "MB4233", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 183549.5, + 249154.0 + ], + "IO": "MB4233", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4234@3": { + "A": "0", + "B": "MB4234", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.5, + 399154.0 + ], + "IO": "MB4234", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4234@2": { + "A": "0", + "B": "MB4234", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 182749.5, + 249154.0 + ], + "IO": "MB4234", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4235@3": { + "A": "0", + "B": "MB4235", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.5, + 399154.0 + ], + "IO": "MB4235", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4235@2": { + "A": "0", + "B": "MB4235", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181949.5, + 249154.0 + ], + "IO": "MB4235", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4236@3": { + "A": "0", + "B": "MB4236", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181149.5, + 399154.0 + ], + "IO": "MB4236", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4236@2": { + "A": "0", + "B": "MB4236", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 181149.5, + 249154.0 + ], + "IO": "MB4236", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4200@3": { + "A": "0", + "B": "MB4200", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187526.0, + 399131.1 + ], + "IO": "MB4200", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4200@2": { + "A": "0", + "B": "MB4200", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187526.0, + 249131.1 + ], + "IO": "MB4200", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4204@3": { + "A": "0", + "B": "MB4204", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187034.5, + 400687.1 + ], + "IO": "MB4204", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV 2305)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4204@2": { + "A": "0", + "B": "MB4204", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187034.5, + 250687.1 + ], + "IO": "MB4204", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV 1305)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4244@3": { + "A": "0", + "B": "MB4244", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175153.1, + 399156.0 + ], + "IO": "MB4244", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4244@2": { + "A": "0", + "B": "MB4244", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175153.1, + 249156.0 + ], + "IO": "MB4244", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4243@3": { + "A": "0", + "B": "MB4243", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175953.1, + 399156.0 + ], + "IO": "MB4243", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4243@2": { + "A": "0", + "B": "MB4243", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 175953.1, + 249156.0 + ], + "IO": "MB4243", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4242@3": { + "A": "0", + "B": "MB4242", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176751.8, + 399154.0 + ], + "IO": "MB4242", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4242@2": { + "A": "0", + "B": "MB4242", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176751.8, + 249154.0 + ], + "IO": "MB4242", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4241@3": { + "A": "0", + "B": "MB4241", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177538.8, + 399156.0 + ], + "IO": "MB4241", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4241@2": { + "A": "0", + "B": "MB4241", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 177538.8, + 249156.0 + ], + "IO": "MB4241", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4240@3": { + "A": "0", + "B": "MB4240", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178351.8, + 399154.0 + ], + "IO": "MB4240", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4240@2": { + "A": "0", + "B": "MB4240", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178351.8, + 249154.0 + ], + "IO": "MB4240", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4237@3": { + "A": "0", + "B": "MB4237", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179151.8, + 399154.0 + ], + "IO": "MB4237", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.3.1)", + "KENNZEICHNUNG": "=A01+UC3301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4237@2": { + "A": "0", + "B": "MB4237", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179151.8, + 249154.0 + ], + "IO": "MB4237", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.3.1)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4260@3": { + "A": "0", + "B": "MB4260", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204280.0, + 399105.2 + ], + "IO": "MB4260", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4260@2": { + "A": "0", + "B": "MB4260", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204280.0, + 249105.2 + ], + "IO": "MB4260", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4264@3": { + "A": "0", + "B": "MB4264", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204234.5, + 400687.1 + ], + "IO": "MB4264", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV 2306)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4264@2": { + "A": "0", + "B": "MB4264", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204234.5, + 250687.1 + ], + "IO": "MB4264", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1306)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4305@3": { + "A": "0", + "B": "MB4305", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191308.1, + 399156.1 + ], + "IO": "MB4305", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4305@2": { + "A": "0", + "B": "MB4305", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 191308.1, + 249156.1 + ], + "IO": "MB4305", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4306@3": { + "A": "0", + "B": "MB4306", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190508.1, + 399156.1 + ], + "IO": "MB4306", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4306@2": { + "A": "0", + "B": "MB4306", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 190508.1, + 249156.1 + ], + "IO": "MB4306", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4307@3": { + "A": "0", + "B": "MB4307", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189730.5, + 399156.1 + ], + "IO": "MB4307", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4307@2": { + "A": "0", + "B": "MB4307", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 189730.5, + 249156.1 + ], + "IO": "MB4307", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4310@3": { + "A": "0", + "B": "MB4310", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188956.2, + 399156.1 + ], + "IO": "MB4310", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4310@2": { + "A": "0", + "B": "MB4310", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188956.2, + 249156.1 + ], + "IO": "MB4310", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4290@3": { + "A": "0", + "B": "MB4290", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203149.6, + 399178.8 + ], + "IO": "MB4290", + "ID": "MB4290", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4290@2": { + "A": "0", + "B": "MB4290", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 203149.6, + 249178.8 + ], + "IO": "MB4290", + "ID": "MB4290", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4291@3": { + "A": "0", + "B": "MB4291", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202349.5, + 399161.6 + ], + "IO": "MB4291", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4291@2": { + "A": "0", + "B": "MB4291", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202349.5, + 249161.6 + ], + "IO": "MB4291", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4292@3": { + "A": "0", + "B": "MB4292", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201548.7, + 399161.6 + ], + "IO": "MB4292", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4292@2": { + "A": "0", + "B": "MB4292", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 201548.7, + 249161.6 + ], + "IO": "MB4292", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4293@3": { + "A": "0", + "B": "MB4293", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200749.5, + 399154.0 + ], + "IO": "MB4293", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4293@2": { + "A": "0", + "B": "MB4293", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 200749.5, + 249154.0 + ], + "IO": "MB4293", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4294@3": { + "A": "0", + "B": "MB4294", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199949.5, + 399154.0 + ], + "IO": "MB4294", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4294@2": { + "A": "0", + "B": "MB4294", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199949.5, + 249154.0 + ], + "IO": "MB4294", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4295@3": { + "A": "0", + "B": "MB4295", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199149.5, + 399154.0 + ], + "IO": "MB4295", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4295@2": { + "A": "0", + "B": "MB4295", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 199149.5, + 249154.0 + ], + "IO": "MB4295", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4296@3": { + "A": "0", + "B": "MB4296", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197959.4, + 399154.0 + ], + "IO": "MB4296", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4296@2": { + "A": "0", + "B": "MB4296", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197959.4, + 249154.0 + ], + "IO": "MB4296", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4304@3": { + "A": "0", + "B": "MB4304", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193153.1, + 399156.0 + ], + "IO": "MB4304", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4304@2": { + "A": "0", + "B": "MB4304", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193153.1, + 249156.0 + ], + "IO": "MB4304", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4303@3": { + "A": "0", + "B": "MB4303", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193953.1, + 399156.0 + ], + "IO": "MB4303", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4303@2": { + "A": "0", + "B": "MB4303", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 193953.1, + 249156.0 + ], + "IO": "MB4303", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4302@3": { + "A": "0", + "B": "MB4302", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194751.8, + 399154.0 + ], + "IO": "MB4302", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4302@2": { + "A": "0", + "B": "MB4302", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 194751.8, + 249154.0 + ], + "IO": "MB4302", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4301@3": { + "A": "0", + "B": "MB4301", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195538.8, + 399156.0 + ], + "IO": "MB4301", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4301@2": { + "A": "0", + "B": "MB4301", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 195538.8, + 249156.0 + ], + "IO": "MB4301", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4300@3": { + "A": "0", + "B": "MB4300", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196351.8, + 399154.0 + ], + "IO": "MB4300", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4300@2": { + "A": "0", + "B": "MB4300", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 196351.8, + 249154.0 + ], + "IO": "MB4300", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4297@3": { + "A": "0", + "B": "MB4297", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197151.8, + 399154.0 + ], + "IO": "MB4297", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.3.2)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4297@2": { + "A": "0", + "B": "MB4297", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197151.8, + 249154.0 + ], + "IO": "MB4297", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.3.2)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4324@3": { + "A": "0", + "B": "MB4324", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206399.4, + 400698.3 + ], + "IO": "MB4324", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator1 (ILS-CV 2307)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4324@2": { + "A": "0", + "B": "MB4324", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206399.4, + 250698.3 + ], + "IO": "MB4324", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1307)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4320@3": { + "A": "0", + "B": "MB4320", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207436.2, + 399033.1 + ], + "IO": "MB4320", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4320@2": { + "A": "0", + "B": "MB4320", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207440.6, + 249103.6 + ], + "IO": "MB4320", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4337@3": { + "A": "0", + "B": "MB4337", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206958.8, + 398419.7 + ], + "IO": "MB4337", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4337@2": { + "A": "0", + "B": "MB4337", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 207511.0, + 248416.5 + ], + "IO": "MB4337", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4350@3": { + "A": "0", + "B": "MB4350", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208186.7, + 399164.6 + ], + "IO": "MB4350", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4350@2": { + "A": "0", + "B": "MB4350", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208186.7, + 249164.6 + ], + "IO": "MB4350", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4351@3": { + "A": "0", + "B": "MB4351", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208964.9, + 399161.8 + ], + "IO": "MB4351", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4351@2": { + "A": "0", + "B": "MB4351", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 208964.9, + 249161.8 + ], + "IO": "MB4351", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4352@3": { + "A": "0", + "B": "MB4352", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209764.9, + 399161.8 + ], + "IO": "MB4352", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4352@2": { + "A": "0", + "B": "MB4352", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 209764.9, + 249161.8 + ], + "IO": "MB4352", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4353@3": { + "A": "0", + "B": "MB4353", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210612.9, + 399161.8 + ], + "IO": "MB4353", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4353@2": { + "A": "0", + "B": "MB4353", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210612.9, + 249161.8 + ], + "IO": "MB4353", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4354@3": { + "A": "0", + "B": "MB4354", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211472.9, + 399161.8 + ], + "IO": "MB4354", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4354@2": { + "A": "0", + "B": "MB4354", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211472.9, + 249161.8 + ], + "IO": "MB4354", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4355@3": { + "A": "0", + "B": "MB4355", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212272.9, + 399161.9 + ], + "IO": "MB4355", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4355@2": { + "A": "0", + "B": "MB4355", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 212272.9, + 249161.9 + ], + "IO": "MB4355", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4356@3": { + "A": "0", + "B": "MB4356", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213072.0, + 399161.8 + ], + "IO": "MB4356", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4356@2": { + "A": "0", + "B": "MB4356", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213072.0, + 249161.8 + ], + "IO": "MB4356", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4357@3": { + "A": "0", + "B": "MB4357", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213842.9, + 399161.8 + ], + "IO": "MB4357", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4357@2": { + "A": "0", + "B": "MB4357", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213842.9, + 249161.8 + ], + "IO": "MB4357", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4360@3": { + "A": "0", + "B": "MB4360", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214672.9, + 399161.8 + ], + "IO": "MB4360", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4360@2": { + "A": "0", + "B": "MB4360", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214672.9, + 249161.8 + ], + "IO": "MB4360", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4361@3": { + "A": "0", + "B": "MB4361", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216418.1, + 399161.8 + ], + "IO": "MB4361", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4361@2": { + "A": "0", + "B": "MB4361", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216418.1, + 249161.8 + ], + "IO": "MB4361", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4362@3": { + "A": "0", + "B": "MB4362", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217218.1, + 399161.8 + ], + "IO": "MB4362", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4362@2": { + "A": "0", + "B": "MB4362", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217218.1, + 249161.8 + ], + "IO": "MB4362", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4363@3": { + "A": "0", + "B": "MB4363", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218018.1, + 399161.7 + ], + "IO": "MB4363", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4363@2": { + "A": "0", + "B": "MB4363", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218018.1, + 249161.7 + ], + "IO": "MB4363", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4364@3": { + "A": "0", + "B": "MB4364", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218817.3, + 399161.7 + ], + "IO": "MB4364", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4364@2": { + "A": "0", + "B": "MB4364", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218817.3, + 249161.7 + ], + "IO": "MB4364", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4365@3": { + "A": "0", + "B": "MB4365", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219618.1, + 399161.7 + ], + "IO": "MB4365", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4365@2": { + "A": "0", + "B": "MB4365", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219618.1, + 249161.7 + ], + "IO": "MB4365", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4366@3": { + "A": "0", + "B": "MB4366", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220418.1, + 399161.8 + ], + "IO": "MB4366", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4366@2": { + "A": "0", + "B": "MB4366", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220418.1, + 249161.8 + ], + "IO": "MB4366", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4367@3": { + "A": "0", + "B": "MB4367", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221218.1, + 399161.7 + ], + "IO": "MB4367", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4367@2": { + "A": "0", + "B": "MB4367", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221218.1, + 249161.7 + ], + "IO": "MB4367", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4370@3": { + "A": "0", + "B": "MB4370", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222418.1, + 399161.8 + ], + "IO": "MB4370", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4370@2": { + "A": "0", + "B": "MB4370", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222418.1, + 249161.8 + ], + "IO": "MB4370", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4371@3": { + "A": "0", + "B": "MB4371", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223218.1, + 399161.8 + ], + "IO": "MB4371", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.18 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4371@2": { + "A": "0", + "B": "MB4371", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223218.1, + 249161.8 + ], + "IO": "MB4371", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.18 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4372@3": { + "A": "0", + "B": "MB4372", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224018.1, + 399161.8 + ], + "IO": "MB4372", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.19 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4372@2": { + "A": "0", + "B": "MB4372", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224018.1, + 249161.8 + ], + "IO": "MB4372", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.19 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4373@3": { + "A": "0", + "B": "MB4373", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224818.1, + 399161.8 + ], + "IO": "MB4373", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.20 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4373@2": { + "A": "0", + "B": "MB4373", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224818.1, + 249161.8 + ], + "IO": "MB4373", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.20 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4374@3": { + "A": "0", + "B": "MB4374", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225618.1, + 399161.8 + ], + "IO": "MB4374", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.21 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4374@2": { + "A": "0", + "B": "MB4374", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225618.1, + 249161.8 + ], + "IO": "MB4374", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.21 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4334@3": { + "A": "0", + "B": "MB4334", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226182.6, + 397923.7 + ], + "IO": "MB4334", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4334@2": { + "A": "0", + "B": "MB4334", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214566.0, + 247440.1 + ], + "IO": "MB4334", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.3.3)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4384@3": { + "A": "0", + "B": "MB4384", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227555.6, + 400698.3 + ], + "IO": "MB4384", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M2308)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4384@2": { + "A": "0", + "B": "MB4384", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227404.1, + 250695.6 + ], + "IO": "MB4384", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1308)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4380@3": { + "A": "0", + "B": "MB4380", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227459.1, + 399144.9 + ], + "IO": "MB4380", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4380@2": { + "A": "0", + "B": "MB4380", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227459.1, + 249144.9 + ], + "IO": "MB4380", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4410@3": { + "A": "0", + "B": "MB4410", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229028.8, + 399164.6 + ], + "IO": "MB4410", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4410@2": { + "A": "0", + "B": "MB4410", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229028.8, + 249164.6 + ], + "IO": "MB4410", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4411@3": { + "A": "0", + "B": "MB4411", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229807.0, + 399161.8 + ], + "IO": "MB4411", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4411@2": { + "A": "0", + "B": "MB4411", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229807.0, + 249161.8 + ], + "IO": "MB4411", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.2 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4412@3": { + "A": "0", + "B": "MB4412", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230607.0, + 399161.8 + ], + "IO": "MB4412", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4412@2": { + "A": "0", + "B": "MB4412", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230607.0, + 249161.8 + ], + "IO": "MB4412", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.3 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4413@3": { + "A": "0", + "B": "MB4413", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231395.0, + 399161.8 + ], + "IO": "MB4413", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4413@2": { + "A": "0", + "B": "MB4413", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 231455.0, + 249161.8 + ], + "IO": "MB4413", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.4 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4414@3": { + "A": "0", + "B": "MB4414", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232207.2, + 399161.8 + ], + "IO": "MB4414", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4414@2": { + "A": "0", + "B": "MB4414", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232315.0, + 249161.8 + ], + "IO": "MB4414", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.5 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4415@3": { + "A": "0", + "B": "MB4415", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232994.5, + 399161.9 + ], + "IO": "MB4415", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4415@2": { + "A": "0", + "B": "MB4415", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233115.0, + 249161.9 + ], + "IO": "MB4415", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.6 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4416@3": { + "A": "0", + "B": "MB4416", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233757.4, + 399161.8 + ], + "IO": "MB4416", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4416@2": { + "A": "0", + "B": "MB4416", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 233914.1, + 249161.8 + ], + "IO": "MB4416", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.7 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4417@3": { + "A": "0", + "B": "MB4417", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234534.0, + 399161.8 + ], + "IO": "MB4417", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4417@2": { + "A": "0", + "B": "MB4417", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234685.0, + 249161.8 + ], + "IO": "MB4417", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.8 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4420@3": { + "A": "0", + "B": "MB4420", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235376.9, + 399161.8 + ], + "IO": "MB4420", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4420@2": { + "A": "0", + "B": "MB4420", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235515.0, + 249161.8 + ], + "IO": "MB4420", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.9 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4421@3": { + "A": "0", + "B": "MB4421", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236149.8, + 399161.8 + ], + "IO": "MB4421", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4421@2": { + "A": "0", + "B": "MB4421", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236287.9, + 249161.8 + ], + "IO": "MB4421", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.10 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4422@3": { + "A": "0", + "B": "MB4422", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236949.8, + 399161.8 + ], + "IO": "MB4422", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4422@2": { + "A": "0", + "B": "MB4422", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237087.9, + 249161.8 + ], + "IO": "MB4422", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.11 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4423@3": { + "A": "0", + "B": "MB4423", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237749.8, + 399161.7 + ], + "IO": "MB4423", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4423@2": { + "A": "0", + "B": "MB4423", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237887.9, + 249161.7 + ], + "IO": "MB4423", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.12 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4424@3": { + "A": "0", + "B": "MB4424", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238687.1, + 399161.7 + ], + "IO": "MB4424", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4424@2": { + "A": "0", + "B": "MB4424", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238687.1, + 249161.7 + ], + "IO": "MB4424", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.13 (Block 1.3.4)", + "KENNZEICHNUNG": "=A01+UC2304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3192@3": { + "A": "0", + "B": "MB3192", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241338.5, + 458174.2 + ], + "IO": "MB3192", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (KR-M2102 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3104-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4444@3": { + "A": "0", + "B": "MB4444", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242270.9, + 457436.7 + ], + "IO": "MB4444", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (KR-K2110)", + "KENNZEICHNUNG": "=A01+UC0309-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4444@2": { + "A": "0", + "B": "MB4444", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241877.4, + 300752.7 + ], + "IO": "MB4444", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M0801)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3143@2": { + "A": "0", + "B": "MB3143", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222435.2, + 461173.2 + ], + "IO": "MB3143", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M1109) ", + "KENNZEICHNUNG": "=A01+UC2103-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3622@2": { + "A": "0", + "B": "MB3622", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223412.7, + 439402.9 + ], + "IO": "MB3622", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M1209)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3614@3": { + "A": "0", + "B": "MB3614", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227454.7, + 439502.0 + ], + "IO": "MB3614", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3614@2": { + "A": "0", + "B": "MB3614", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214544.0, + 288761.5 + ], + "IO": "MB3614", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 1.2.3)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3615@3": { + "A": "0", + "B": "MB3615", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226329.7, + 438116.2 + ], + "IO": "MB3615", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M2209 Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC0307-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3431@3": { + "A": "0", + "B": "MB3431", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240232.5, + 440533.4 + ], + "IO": "MB3431", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (ILS-CV M2104 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3432@3": { + "A": "0", + "B": "MB3432", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237421.5, + 440659.3 + ], + "IO": "MB3432", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M2109 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3432@5": { + "A": "0", + "B": "MB3432", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236300.3, + 150853.2 + ], + "IO": "MB3432", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3432@4": { + "A": "0", + "B": "MB3432", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356092.5, + 749704.3 + ], + "IO": "MB3432", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3672@3": { + "A": "0", + "B": "MB3672", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241308.0, + 437076.6 + ], + "IO": "MB3672", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4091@3": { + "A": "0", + "B": "MB4091", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226101.9, + 419768.6 + ], + "IO": "MB4091", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV 2309)", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3912@3": { + "A": "0", + "B": "MB3912", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238124.1, + 421093.7 + ], + "IO": "MB3912", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (ILS-CV M2209 Block 2.1.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3910@3": { + "A": "0", + "B": "MB3910", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240407.6, + 421007.9 + ], + "IO": "MB3910", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (Block 2.2.4)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4145@3": { + "A": "0", + "B": "MB4145", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240382.0, + 417822.1 + ], + "IO": "MB4145", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4185@3": { + "A": "0", + "B": "MB4185", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241151.5, + 416323.7 + ], + "IO": "MB4185", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4186@3": { + "A": "0", + "B": "MB4186", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241951.5, + 416323.7 + ], + "IO": "MB4186", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4146@3": { + "A": "0", + "B": "MB4146", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241436.8, + 418448.2 + ], + "IO": "MB4146", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M2302 Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3208-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4342@2": { + "A": "0", + "B": "MB4342", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224215.4, + 397344.7 + ], + "IO": "MB4342", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M1309) ", + "KENNZEICHNUNG": "=A01+UC2303-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4335@3": { + "A": "0", + "B": "MB4335", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225391.7, + 397923.7 + ], + "IO": "MB4335", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1309 Block 2.2.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4425@3": { + "A": "0", + "B": "MB4425", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240687.1, + 399161.7 + ], + "IO": "MB4425", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4426@3": { + "A": "0", + "B": "MB4426", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241487.1, + 399161.7 + ], + "IO": "MB4426", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4440@3": { + "A": "0", + "B": "MB4440", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244310.6, + 457948.9 + ], + "IO": "MB4440", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (ILS-CF 2111)", + "KENNZEICHNUNG": "=A01+UC0309-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4440@2": { + "A": "0", + "B": "MB4440", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242124.4, + 299796.8 + ], + "IO": "MB4440", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (KR-M1100)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4540@2": { + "A": "0", + "B": "MB4540", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240343.6, + 423707.5 + ], + "IO": "MB4540", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1501) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4543@2": { + "A": "0", + "B": "MB4543", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242660.5, + 420150.2 + ], + "IO": "MB4543", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1601) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4500@3": { + "A": "0", + "B": "MB4500", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243528.6, + 436434.2 + ], + "IO": "MB4500", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (KR-M2110)", + "KENNZEICHNUNG": "=A01+UC0310-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4500@2": { + "A": "0", + "B": "MB4500", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244407.9, + 289928.4 + ], + "IO": "MB4500", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M1100)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4503@3": { + "A": "0", + "B": "MB4503", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244342.1, + 431310.4 + ], + "IO": "MB4503", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (KR-M2110)", + "KENNZEICHNUNG": "=A01+UC0310-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4503@2": { + "A": "0", + "B": "MB4503", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242272.2, + 288536.3 + ], + "IO": "MB4503", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M4701)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4395@3": { + "A": "0", + "B": "MB4395", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242293.8, + 400821.2 + ], + "IO": "MB4395", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (KR-K2210 Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4505@3": { + "A": "0", + "B": "MB4505", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242289.3, + 430164.0 + ], + "IO": "MB4505", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (KR-2110-2210)", + "KENNZEICHNUNG": "=A01+UC0310-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4505@2": { + "A": "0", + "B": "MB4505", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244473.8, + 280301.6 + ], + "IO": "MB4505", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (KR-M1100)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4392@3": { + "A": "0", + "B": "MB4392", + "C": "20073710081010151939", + "ARTINR": "722001306", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 20m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242809.6, + 398378.8 + ], + "IO": "MB4392", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV K2210 Block 2.3.4)", + "KENNZEICHNUNG": "=A01+UC3304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3786@3": { + "A": "0", + "B": "MB3786", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204998.8, + 420785.7 + ], + "IO": "MB3786", + "ID": "", + "VERW": "Switch left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links (Auslagerkreisel Block 2, KR-2203-2204)", + "KENNZEICHNUNG": "=A01+UC3202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3786@2": { + "A": "0", + "B": "MB3786", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204998.8, + 270785.7 + ], + "IO": "MB3786", + "ID": "", + "VERW": "Switch left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links (Auslagerkreisel Block 2, KR-1103-1104)", + "KENNZEICHNUNG": "=A01+UC2202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3306@3": { + "A": "0", + "B": "MB3306", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204993.4, + 440589.9 + ], + "IO": "MB3306", + "ID": "", + "VERW": "Switch left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links (Auslagerkreisel Block 1, KR-2103-2104)", + "KENNZEICHNUNG": "=A01+UC0302-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3306@2": { + "A": "0", + "B": "MB3306", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204993.4, + 290589.9 + ], + "IO": "MB3306", + "ID": "", + "VERW": "Switch left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links (Auslagerkreisel Block 1, KR-1103-1104)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3306@5": { + "A": "0", + "B": "MB3306", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226319.0, + 150442.5 + ], + "IO": "MB3306", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 5m", + "SPS": "5" + }, + "MB3306@4": { + "A": "0", + "B": "MB3306", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356210.4, + 728297.3 + ], + "IO": "MB3306", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (AMR ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3306@1": { + "A": "0", + "B": "MB3306", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 333164.0, + 152697.8 + ], + "IO": "MB3306", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-KR-M0102)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB4026@3": { + "A": "0", + "B": "MB4026", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205013.2, + 418602.8 + ], + "IO": "MB4026", + "ID": "", + "VERW": "Switch left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links (Auslagerkreisel Block 3, KR-2301-2302)", + "KENNZEICHNUNG": "=A01+UC3206-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4026@2": { + "A": "0", + "B": "MB4026", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205013.2, + 268602.8 + ], + "IO": "MB4026", + "ID": "", + "VERW": "switch left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links (Auslagerkreisel Block 3, KR-1301-1302)", + "KENNZEICHNUNG": "=A01+UC2206-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3673@3": { + "A": "0", + "B": "MB3673", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242138.2, + 437070.5 + ], + "IO": "MB3673", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1401)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3965@3": { + "A": "0", + "B": "MB3965", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170987.2, + 418616.3 + ], + "IO": "MB3965", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (KR-M2301)", + "KENNZEICHNUNG": "=A01+UC3205-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3965@2": { + "A": "0", + "B": "MB3965", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170988.5, + 268579.5 + ], + "IO": "MB3965", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (KR-M1301)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3725@3": { + "A": "0", + "B": "MB3725", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 176343.8, + 421145.4 + ], + "IO": "MB3725", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (KR-M2203)", + "KENNZEICHNUNG": "=A01+UC3201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3725@2": { + "A": "0", + "B": "MB3725", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170660.3, + 271155.4 + ], + "IO": "MB3725", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (KR-M1203)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3245@3": { + "A": "0", + "B": "MB3245", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170876.7, + 440631.7 + ], + "IO": "MB3245", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (KR-M2103)", + "KENNZEICHNUNG": "=A01+UC0301-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3245@2": { + "A": "0", + "B": "MB3245", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170687.9, + 290646.8 + ], + "IO": "MB3245", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (KR-M1103)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3245@5": { + "A": "0", + "B": "MB3245", + "C": "10073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218685.4, + 153801.4 + ], + "IO": "MB3245", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M5003)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 5m", + "SPS": "5" + }, + "BG3673@3": { + "A": "0", + "B": "BG3673", + "C": "20073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243244.3, + 438702.1 + ], + "IO": "BG3673", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2202)", + "KENNZEICHNUNG": "=A01+UC0308-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3141@2": { + "A": "0", + "B": "BG3141", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 210664.8, + 309586.4 + ], + "IO": "BG3141", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (KR-M1102)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3492@2": { + "A": "0", + "B": "BG3492", + "C": "20073710081010151939", + "ARTINR": "829422026", + "BESCHR": "Induktiver Sesnor LP kpl.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172109.4, + 288122.4 + ], + "IO": "BG3492", + "ID": "", + "VERW": "Sync P5", + "BEZEICHNUNG": "Prüfung MT Pos.5 (KR-K1201 Einfahrt Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3532@2": { + "A": "0", + "B": "BG3532", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.1, + 286822.0 + ], + "IO": "BG3532", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.19 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.19", + "SPS": "2" + }, + "BG3531@2": { + "A": "0", + "B": "BG3531", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 286822.3 + ], + "IO": "BG3531", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.18 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.18", + "SPS": "2" + }, + "BG3530@2": { + "A": "0", + "B": "BG3530", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 286822.3 + ], + "IO": "BG3530", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.17 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.17", + "SPS": "2" + }, + "BG3527@2": { + "A": "0", + "B": "BG3527", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.1, + 286822.0 + ], + "IO": "BG3527", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.16 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.16", + "SPS": "2" + }, + "BG3526@2": { + "A": "0", + "B": "BG3526", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 286822.3 + ], + "IO": "BG3526", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.15 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.15", + "SPS": "2" + }, + "BG3525@2": { + "A": "0", + "B": "BG3525", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 286822.3 + ], + "IO": "BG3525", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.14 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.14", + "SPS": "2" + }, + "BG3621@2": { + "A": "0", + "B": "BG3621", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 211984.0, + 288490.9 + ], + "IO": "BG3621", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (KR-M1202)", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3772@2": { + "A": "0", + "B": "BG3772", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 273167.6 + ], + "IO": "BG3772", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "In Separator 19 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.19", + "SPS": "2" + }, + "BG3766@2": { + "A": "0", + "B": "BG3766", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 273167.6 + ], + "IO": "BG3766", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 15 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.15", + "SPS": "2" + }, + "BG3765@2": { + "A": "0", + "B": "BG3765", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 273167.6 + ], + "IO": "BG3765", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 14 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.14", + "SPS": "2" + }, + "BG3767@2": { + "A": "0", + "B": "BG3767", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 273167.6 + ], + "IO": "BG3767", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 16 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.16", + "SPS": "2" + }, + "BG3771@2": { + "A": "0", + "B": "BG3771", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 273167.6 + ], + "IO": "BG3771", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 18 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.18", + "SPS": "2" + }, + "BG3770@2": { + "A": "0", + "B": "BG3770", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 273167.6 + ], + "IO": "BG3770", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 17 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "1.2.1.17", + "SPS": "2" + }, + "MB4455@2": { + "A": "0", + "B": "MB4455", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243464.9, + 301822.0 + ], + "IO": "MB4455", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M0701)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4455@2": { + "A": "0", + "B": "BG4455", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243464.9, + 302133.5 + ], + "IO": "BG4455", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M0510)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4451@2": { + "A": "0", + "B": "BG4451", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243550.4, + 297404.2 + ], + "IO": "BG4451", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (KR-M1100)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4451@3": { + "A": "0", + "B": "BG4451", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239867.2, + 153134.1 + ], + "IO": "BG4451", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2111)", + "KENNZEICHNUNG": "=A01+UC0309-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4445@2": { + "A": "0", + "B": "BG4445", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241231.0, + 297635.9 + ], + "IO": "BG4445", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 1 (ILS-CV M1401)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4447@2": { + "A": "0", + "B": "BG4447", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241231.0, + 297103.0 + ], + "IO": "BG4447", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M1401)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4446@2": { + "A": "0", + "B": "BG4446", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241231.0, + 296483.4 + ], + "IO": "BG4446", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1401)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4525@2": { + "A": "0", + "B": "BG4525", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242997.3, + 278385.7 + ], + "IO": "BG4525", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (CV-M1601)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4524@2": { + "A": "0", + "B": "BG4524", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242990.9, + 277686.3 + ], + "IO": "BG4524", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (CV-M1601)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4521@2": { + "A": "0", + "B": "BG4521", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240313.2, + 278336.0 + ], + "IO": "BG4521", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (M1501)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4520@2": { + "A": "0", + "B": "BG4520", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 240322.6, + 277460.8 + ], + "IO": "BG4520", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (CV-M1501)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4526@2": { + "A": "0", + "B": "BG4526", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242997.3, + 278674.6 + ], + "IO": "BG4526", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (CV-M1601)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4512@2": { + "A": "0", + "B": "BG4512", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244470.6, + 281131.5 + ], + "IO": "BG4512", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (KR-M1100)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4203@2": { + "A": "0", + "B": "BG4203", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187373.2, + 249998.6 + ], + "IO": "BG4203", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M1303)", + "KENNZEICHNUNG": "=A01+UC2301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4203@3": { + "A": "0", + "B": "BG4203", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187183.8, + 399827.1 + ], + "IO": "BG4203", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2303 ) Block 2.3.1", + "KENNZEICHNUNG": "=A01+UC3301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4263@2": { + "A": "0", + "B": "BG4263", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204530.3, + 249939.0 + ], + "IO": "BG4263", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M1303)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4263@3": { + "A": "0", + "B": "BG4263", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204499.3, + 399939.0 + ], + "IO": "BG4263", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2303)", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4340@2": { + "A": "0", + "B": "BG4340", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213419.1, + 248422.2 + ], + "IO": "BG4340", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1304)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4336@2": { + "A": "0", + "B": "BG4336", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217822.8, + 247179.6 + ], + "IO": "BG4336", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M1309)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4336@3": { + "A": "0", + "B": "BG4336", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224762.2, + 398517.3 + ], + "IO": "BG4336", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 1 (M2309)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4454@2": { + "A": "0", + "B": "BG4454", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243464.9, + 301342.1 + ], + "IO": "BG4454", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 8 (ILS-KR M1100)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4453@2": { + "A": "0", + "B": "BG4453", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243551.7, + 298794.7 + ], + "IO": "BG4453", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 6 (ILS-KR M1100)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4514@2": { + "A": "0", + "B": "BG4514", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242075.2, + 282938.1 + ], + "IO": "BG4514", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 4 (CV-M1100)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4530@2": { + "A": "0", + "B": "BG4530", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244403.6, + 288741.1 + ], + "IO": "BG4530", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M4701) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4504@2": { + "A": "0", + "B": "MB4504", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242272.2, + 287709.1 + ], + "IO": "MB4504", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M1801)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4532@2": { + "A": "0", + "B": "BG4532", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244623.7, + 287826.5 + ], + "IO": "BG4532", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (CV-M4701)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4561@2": { + "A": "0", + "B": "BG4561", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250235.0, + 295258.3 + ], + "IO": "BG4561", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor(ILS-CV M1801)", + "KENNZEICHNUNG": "=A01+UC0211-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3440@3": { + "A": "0", + "B": "BG3440", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229500.6, + 290448.6 + ], + "IO": "BG3440", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2109)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3440@1": { + "A": "0", + "B": "BG3440", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237453.9, + 150858.0 + ], + "IO": "BG3440", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Längenabfrage Grenze kurz (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI2", + "TEXT-D": "", + "TEXT-E": "Teil vorhanden", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3442@3": { + "A": "0", + "B": "BG3442", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230256.8, + 290458.4 + ], + "IO": "BG3442", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2109)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3442@4": { + "A": "0", + "B": "BG3442", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 353896.7, + 750397.5 + ], + "IO": "BG3442", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4008)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3442@1": { + "A": "0", + "B": "BG3442", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237453.9, + 150318.0 + ], + "IO": "BG3442", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Längenabfrage Grenze zu lang (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI2", + "TEXT-D": "", + "TEXT-E": "Teil zu lang", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3441@3": { + "A": "0", + "B": "BG3441", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230985.6, + 290448.6 + ], + "IO": "BG3441", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2109)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3441@4": { + "A": "0", + "B": "BG3441", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356319.8, + 750384.8 + ], + "IO": "BG3441", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 3 (AMR ILS-CV M4008)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3441@1": { + "A": "0", + "B": "BG3441", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237453.9, + 150588.0 + ], + "IO": "BG3441", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Längenabfrage Grenze lang (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI2", + "TEXT-D": "", + "TEXT-E": "Teil lang", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG4097@3": { + "A": "0", + "B": "BG4097", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217452.0, + 269434.4 + ], + "IO": "BG4097", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M2309) ", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4095@3": { + "A": "0", + "B": "BG4095", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216706.8, + 269430.9 + ], + "IO": "BG4095", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M2309) ", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4096@3": { + "A": "0", + "B": "BG4096", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218191.8, + 269431.0 + ], + "IO": "BG4096", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2309) ", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4537@2": { + "A": "0", + "B": "BG4537", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 249412.4, + 296857.3 + ], + "IO": "BG4537", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV 4701) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4535@2": { + "A": "0", + "B": "BG4535", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250894.7, + 296853.9 + ], + "IO": "BG4535", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV 4701) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4536@2": { + "A": "0", + "B": "BG4536", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250152.2, + 296853.9 + ], + "IO": "BG4536", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV 4701) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4563@2": { + "A": "0", + "B": "BG4563", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244623.7, + 286291.8 + ], + "IO": "BG4563", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV 1801)", + "KENNZEICHNUNG": "=A01+UC0211-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4563@3": { + "A": "0", + "B": "BG4563", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 246452.5, + 447225.5 + ], + "IO": "BG4563", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 1 (ILS-CV M4201)", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4151@2": { + "A": "0", + "B": "BG4151", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239455.4, + 266988.5 + ], + "IO": "BG4151", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (KR-M1302)", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3911@2": { + "A": "0", + "B": "BG3911", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238361.0, + 271792.6 + ], + "IO": "BG3911", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M1204)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3922@3": { + "A": "0", + "B": "BG3922", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229775.2, + 269828.2 + ], + "IO": "BG3922", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (CV M2209) ", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3920@3": { + "A": "0", + "B": "BG3920", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229030.0, + 269824.7 + ], + "IO": "BG3920", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2209)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3921@3": { + "A": "0", + "B": "BG3921", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230515.0, + 269824.7 + ], + "IO": "BG3921", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2209)", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3430@2": { + "A": "0", + "B": "BG3430", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229108.7, + 291073.7 + ], + "IO": "BG3430", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 1 (M1104)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3430@5": { + "A": "0", + "B": "BG3430", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236615.2, + 152271.7 + ], + "IO": "BG3430", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3430@4": { + "A": "0", + "B": "BG3430", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356126.6, + 748763.2 + ], + "IO": "BG3430", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator vor MPS 1 (AMR KR-M4003)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG4522@2": { + "A": "0", + "B": "BG4522", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241503.5, + 281505.5 + ], + "IO": "BG4522", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (CV-M1501)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4510@2": { + "A": "0", + "B": "BG4510", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244470.6, + 279014.9 + ], + "IO": "BG4510", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR-M1110)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0076@2": { + "A": "0", + "B": "MA0076", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 249788.0, + 294973.7 + ], + "IO": "MA0076", + "ID": "9999", + "VERW": "KF -M0076_0,55", + "BEZEICHNUNG": "Motor MA0076 (CV-M1801)", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ8", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MA0076@1": { + "A": "0", + "B": "MA0076", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376718.9, + 180300.0 + ], + "IO": "MA0076", + "ID": "9999", + "VERW": "M0076 0,12", + "BEZEICHNUNG": "Motor 2 MA0076 Einfahren LS 2", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor 2, MA0076 Einfahren LS 2", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0266@2": { + "A": "0", + "B": "MA0266", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217083.0, + 247179.3 + ], + "IO": "MA0266", + "ID": "9999", + "VERW": "ILS-CV M1309", + "BEZEICHNUNG": "Motor MA0266 (CV-M1309)", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ3", + "TEXT-D": "Motor MA0266", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3426@2": { + "A": "0", + "B": "MB3426", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228009.0, + 290412.1 + ], + "IO": "MB3426", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M2109 Block 1.1.4)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3525@2": { + "A": "0", + "B": "MB3525", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174007.5, + 287818.9 + ], + "IO": "MB3525", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.14 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3526@2": { + "A": "0", + "B": "MB3526", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173207.5, + 287818.9 + ], + "IO": "MB3526", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.15 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3527@2": { + "A": "0", + "B": "MB3527", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172429.9, + 287818.9 + ], + "IO": "MB3527", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.16 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3530@2": { + "A": "0", + "B": "MB3530", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171655.7, + 287818.9 + ], + "IO": "MB3530", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.17 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3531@2": { + "A": "0", + "B": "MB3531", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170882.8, + 287818.9 + ], + "IO": "MB3531", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.18 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3532@2": { + "A": "0", + "B": "MB3532", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170129.0, + 287818.9 + ], + "IO": "MB3532", + "ID": "", + "VERW": "ES branch", + "BEZEICHNUNG": "AE Abzweig Str.19 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC0205-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3772@2": { + "A": "0", + "B": "MB3772", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170000.0, + 273437.6 + ], + "IO": "MB3772", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 19 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3766@2": { + "A": "0", + "B": "MB3766", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 173200.0, + 273437.6 + ], + "IO": "MB3766", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 15 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3765@2": { + "A": "0", + "B": "MB3765", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 174000.0, + 273437.6 + ], + "IO": "MB3765", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 14 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3767@2": { + "A": "0", + "B": "MB3767", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 172400.0, + 273437.6 + ], + "IO": "MB3767", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 16 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3771@2": { + "A": "0", + "B": "MB3771", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 170800.0, + 273437.6 + ], + "IO": "MB3771", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 18 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3770@2": { + "A": "0", + "B": "MB3770", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 171600.0, + 273437.6 + ], + "IO": "MB3770", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 17 (Block 1.2.1)", + "KENNZEICHNUNG": "=A01+UC2201-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3906@2": { + "A": "0", + "B": "MB3906", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 228901.0, + 271240.0 + ], + "IO": "MB3906", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV 1 M2209 Block 1.2.4)", + "KENNZEICHNUNG": "=A01+UC2204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4086@2": { + "A": "0", + "B": "MB4086", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215738.6, + 267740.4 + ], + "IO": "MB4086", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV-M2309)", + "KENNZEICHNUNG": "=A01+UC2207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4451@2": { + "A": "0", + "B": "MB4451", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 243550.4, + 297674.2 + ], + "IO": "MB4451", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (KR-M1100)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4445@2": { + "A": "0", + "B": "MB4445", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241231.0, + 297905.9 + ], + "IO": "MB4445", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV 1401)", + "KENNZEICHNUNG": "=A01+UC0209-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4526@2": { + "A": "0", + "B": "MB4526", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242997.3, + 278944.6 + ], + "IO": "MB4526", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1601)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4512@2": { + "A": "0", + "B": "MB4512", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244470.6, + 281401.5 + ], + "IO": "MB4512", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1501)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4530@2": { + "A": "0", + "B": "MB4530", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244403.6, + 289011.1 + ], + "IO": "MB4530", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M4701) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3440@3": { + "A": "0", + "B": "MB3440", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229500.6, + 290718.6 + ], + "IO": "MB3440", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2109)", + "KENNZEICHNUNG": "=A01+UC0304-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3440@4": { + "A": "0", + "B": "MB3440", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 354359.6, + 749434.4 + ], + "IO": "MB3440", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (AMR ILS-CV M4008)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB4095@3": { + "A": "0", + "B": "MB4095", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216706.8, + 269700.9 + ], + "IO": "MB4095", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M2309) ", + "KENNZEICHNUNG": "=A01+UC3207-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4535@2": { + "A": "0", + "B": "MB4535", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250894.7, + 297137.7 + ], + "IO": "MB4535", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV 4701) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4563@2": { + "A": "0", + "B": "MB4563", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244623.7, + 286561.8 + ], + "IO": "MB4563", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M1801) ", + "KENNZEICHNUNG": "=A01+UC0211-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3920@3": { + "A": "0", + "B": "MB3920", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229030.0, + 270094.7 + ], + "IO": "MB3920", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2209 Block 1.2.4) ", + "KENNZEICHNUNG": "=A01+UC3204-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4522@2": { + "A": "0", + "B": "MB4522", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 241503.5, + 281775.5 + ], + "IO": "MB4522", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV M1501)", + "KENNZEICHNUNG": "=A01+UC0210-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4261@2": { + "A": "0", + "B": "MB4261", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204806.7, + 248509.9 + ], + "IO": "MB4261", + "ID": "MB4261", + "VERW": "switch Left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links (Einlagerkreisel Block 2, KR-1201-1202)", + "KENNZEICHNUNG": "=A01+UC2302-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB4261@3": { + "A": "0", + "B": "MB4261", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204839.4, + 398386.1 + ], + "IO": "MB4261", + "ID": "", + "VERW": "Switch left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links Einlagerkreisel Block 3, KR-2303-2304)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4531@2": { + "A": "0", + "B": "BG4531", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 245185.3, + 288747.6 + ], + "IO": "BG4531", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (CV M4701) ", + "KENNZEICHNUNG": "=A01+UC0211-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG0340@1": { + "A": "0", + "B": "BG0340", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376774.1, + 187154.7 + ], + "IO": "BG0340", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator LS2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG0341@1": { + "A": "0", + "B": "BG0341", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376774.4, + 187772.2 + ], + "IO": "BG0341", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor ", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "MA0320@1": { + "A": "0", + "B": "MA0320", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 373091.7, + 182932.0 + ], + "IO": "MA0320", + "ID": "9999", + "VERW": "KR-M0320 0,55", + "BEZEICHNUNG": "Motor MA0320 Kreisel LS1", + "KENNZEICHNUNG": "=A01+UC0110KF1DQ3", + "TEXT-D": "Motor MA0320 Kreisel LS1", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MA0380@1": { + "A": "0", + "B": "MA0380", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 379125.8, + 182932.0 + ], + "IO": "MA0380", + "ID": "9999", + "VERW": "KR-M0380 0,55", + "BEZEICHNUNG": "Motor MA0380", + "KENNZEICHNUNG": "=A01+UC0111-KF1DQ3", + "TEXT-D": "Motor MA0380", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG0286@1": { + "A": "0", + "B": "BG0286", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370704.6, + 183190.3 + ], + "IO": "BG0286", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Staubereich voll Einfahrt Kreisel", + "KENNZEICHNUNG": "=A01+UC0110KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 5m", + "SPS": "1" + }, + "BG0343@1": { + "A": "0", + "B": "BG0343", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 379125.6, + 187301.8 + ], + "IO": "BG0343", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator ", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "MB0340@1": { + "A": "0", + "B": "MB0340", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376774.1, + 187424.7 + ], + "IO": "MB0340", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator LS2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB0343@1": { + "A": "0", + "B": "MB0343", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 379125.6, + 187571.8 + ], + "IO": "MB0343", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator ", + "KENNZEICHNUNG": "=A01+UC0111-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MA0321@1": { + "A": "0", + "B": "MA0321", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370318.0, + 185761.9 + ], + "IO": "MA0321", + "ID": "9999", + "VERW": "M0321_LS1", + "BEZEICHNUNG": "Motor MA0321 400V Stützfuß LS1", + "KENNZEICHNUNG": "=A01+UC0110KF1DQ3", + "TEXT-D": "Motor MA0321 400V Stützfuß LS1", + "TEXT-E": "Motor MA0321 400V Support foot LS1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG0280@1": { + "A": "0", + "B": "BG0280", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370801.0, + 187134.4 + ], + "IO": "BG0280", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator LS 1", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "MA0280@1": { + "A": "0", + "B": "MA0280", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370812.7, + 187399.6 + ], + "IO": "MA0280", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator LS 1", + "KENNZEICHNUNG": "=A01+UC0110-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MA0282@1": { + "A": "0", + "B": "MA0282", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370806.4, + 188401.0 + ], + "IO": "MA0282", + "ID": "", + "VERW": "Stopper zu", + "BEZEICHNUNG": "Stopper zu, MT fixieren", + "KENNZEICHNUNG": "=A01+UC0110-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG0284@1": { + "A": "0", + "B": "BG0284", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 373091.7, + 186925.6 + ], + "IO": "BG0284", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR- LS 1)", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG0283@1": { + "A": "0", + "B": "BG0283", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 373091.5, + 187302.4 + ], + "IO": "BG0283", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator Beladeposition 2, LS 1", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "MA0283@1": { + "A": "0", + "B": "MA0283", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 373091.5, + 187572.4 + ], + "IO": "MA0283", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator Beladeposition 2, LS 1", + "KENNZEICHNUNG": "=A01+UC0110-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG0285@1": { + "A": "0", + "B": "BG0285", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 373091.7, + 186590.2 + ], + "IO": "BG0285", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Staubereich nach Beladung voll", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG4740@1": { + "A": "0", + "B": "BG4740", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 373091.7, + 185239.1 + ], + "IO": "BG4740", + "ID": "", + "VERW": "Incl.Sensor", + "BEZEICHNUNG": "Neigungssensor Ladeschleife 1", + "KENNZEICHNUNG": "=A01+UC0110-KF1DIQ1", + "TEXT-D": "Neigungssensor Ladeschleife 1", + "TEXT-E": "Inclination sensor Loading Boom 1", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG0053@1": { + "A": "0", + "B": "BG0053", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376715.4, + 179157.8 + ], + "IO": "BG0053", + "ID": "", + "VERW": "LS 2 extended", + "BEZEICHNUNG": "Positionsschalter Ladeschleife 2 ausgefahren", + "KENNZEICHNUNG": "=A01+UH01-KF1DI3", + "TEXT-D": "Positionsschalter Ladeschleife 2 ausgefahren", + "TEXT-E": "Position switch loading boom 2 extended", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "BG0052@1": { + "A": "0", + "B": "BG0052", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376715.4, + 178887.8 + ], + "IO": "BG0052", + "ID": "", + "VERW": "LS 2 retracted", + "BEZEICHNUNG": "Positionsschalter Ladeschleife 2 eingefahren", + "KENNZEICHNUNG": "=A01+UH01-KF1DI3", + "TEXT-D": "Positionsschalter Ladeschleife 2 eingefahren", + "TEXT-E": "Switch for loading boom 2 position retracted", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "MA0284@1": { + "A": "0", + "B": "MA0284", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370806.4, + 188131.0 + ], + "IO": "MA0284", + "ID": "", + "VERW": "Sep LS 1", + "BEZEICHNUNG": "Separator Ladeposition 1, LS 1", + "KENNZEICHNUNG": "=A01+UC0110-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB0342@1": { + "A": "0", + "B": "MB0342", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376773.0, + 188450.9 + ], + "IO": "MB0342", + "ID": "", + "VERW": "Stopper zu", + "BEZEICHNUNG": "Stopper zu, MT fixieren", + "KENNZEICHNUNG": "=A01+UC0111-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB0344@1": { + "A": "0", + "B": "MB0344", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376773.0, + 188180.9 + ], + "IO": "MB0344", + "ID": "", + "VERW": "Sep LS 2", + "BEZEICHNUNG": "Separator Ladeposition 1, LS 2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG0344@1": { + "A": "0", + "B": "BG0344", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 379125.8, + 186925.0 + ], + "IO": "BG0344", + "ID": "", + "VERW": "Rad dreht ", + "BEZEICHNUNG": "Rad dreht (KR- LS 2)", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG0345@1": { + "A": "0", + "B": "BG0345", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 379125.8, + 186589.7 + ], + "IO": "BG0345", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Staubereich nach Beladung voll", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG4741@1": { + "A": "0", + "B": "BG4741", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 379125.8, + 185308.1 + ], + "IO": "BG4741", + "ID": "", + "VERW": "Incl.Sensor", + "BEZEICHNUNG": "Neigungssensor Ladeschleife 2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DIQ1", + "TEXT-D": "Neigungssensor Ladeschleife 2", + "TEXT-E": "Inclination sensor Loading Boom 2", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG4821@1": { + "A": "0", + "B": "BG4821", + "C": "20073710081010151939", + "ARTINR": "720002011", + "BESCHR": "SENSOR INDUK. M18 8MM BÜNDIG/PNP-NO/STM12,", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 379125.8, + 185038.1 + ], + "IO": "BG4821", + "ID": "", + "VERW": "Dist. Sensor", + "BEZEICHNUNG": "Bodenabstandssensor ( LS 2)", + "KENNZEICHNUNG": "=A01+UC0111-KF1DIQ1", + "TEXT-D": "Bodenabstandssensor ( LS 2)", + "TEXT-E": "Floor distance sensor ( LS 2)", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG0346@1": { + "A": "0", + "B": "BG0346", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376704.6, + 183190.3 + ], + "IO": "BG0346", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 2 (KR-M1102)", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 5m", + "SPS": "1" + }, + "BG0282@1": { + "A": "0", + "B": "BG0282", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370806.4, + 188671.0 + ], + "IO": "BG0282", + "ID": "", + "VERW": "In sep LS1", + "BEZEICHNUNG": "in Separator Beladeposition 1, LS 1", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG0342@1": { + "A": "0", + "B": "BG0342", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376776.2, + 188724.9 + ], + "IO": "BG0342", + "ID": "", + "VERW": "In sep LS2", + "BEZEICHNUNG": "in Separator Beladeposition 1, LS 2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG0287@1": { + "A": "0", + "B": "BG0287", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370715.7, + 179601.7 + ], + "IO": "BG0287", + "ID": "", + "VERW": "2m extension", + "BEZEICHNUNG": "Sensor 2m ausgefahren LS 1 ", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 5m", + "SPS": "1" + }, + "BG0347@1": { + "A": "0", + "B": "BG0347", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376715.7, + 179601.7 + ], + "IO": "BG0347", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "LS 2 Sensor 2m ausgefahren", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 5m", + "SPS": "1" + }, + "MB0325@1": { + "A": "0", + "B": "MB0325", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 373091.5, + 188798.1 + ], + "IO": "MB0325", + "ID": "", + "VERW": "Safety relay LS1", + "BEZEICHNUNG": "Reset Bumper Safety relay (LS 1)", + "KENNZEICHNUNG": "=A01+UC0110-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB0385@1": { + "A": "0", + "B": "MB0385", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 379299.9, + 188844.8 + ], + "IO": "MB0385", + "ID": "", + "VERW": "Safety relay LS2", + "BEZEICHNUNG": "Reset Bumper Safety relay (LS2)", + "KENNZEICHNUNG": "=A01+UC0111-KF1DQ3", + "TEXT-D": "Reset Bumper Safety relay (LS2)", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG3427@2": { + "A": "0", + "B": "BG3427", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 293431.6 + ], + "IO": "BG3427", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1108)", + "KENNZEICHNUNG": "=A01+UC0204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3427@5": { + "A": "0", + "B": "BG3427", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236615.2, + 153351.8 + ], + "IO": "BG3427", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3427@3": { + "A": "0", + "B": "BG3427", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 443440.8 + ], + "IO": "BG3427", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2108) ", + "KENNZEICHNUNG": "=A01+UC0304-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3077@1": { + "A": "0", + "B": "BG3077", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359699.3, + 451720.4 + ], + "IO": "BG3077", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 2 (ILS-CV M4403)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3262@4": { + "A": "0", + "B": "BG3262", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 364161.1, + 452111.8 + ], + "IO": "BG3262", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M0401)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3262@1": { + "A": "0", + "B": "BG3262", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329951.2, + 164939.4 + ], + "IO": "BG3262", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.03 (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "1.1.03 ", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3261@4": { + "A": "0", + "B": "BG3261", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 364916.8, + 452104.3 + ], + "IO": "BG3261", + "ID": "", + "VERW": "MT in Position ", + "BEZEICHNUNG": "MT in Position (AMR ILS-CV M0401) ", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3261@1": { + "A": "0", + "B": "BG3261", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 330351.2, + 164939.4 + ], + "IO": "BG3261", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.02 (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "1.1.02 ", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3261@5": { + "A": "0", + "B": "BG3261", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218680.6, + 151246.3 + ], + "IO": "BG3261", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 5m", + "SPS": "5" + }, + "BG4450@3": { + "A": "0", + "B": "BG4450", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239864.5, + 152557.1 + ], + "IO": "BG4450", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M2111)", + "KENNZEICHNUNG": "=A01+UC0309-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4452@3": { + "A": "0", + "B": "BG4452", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239864.5, + 153429.9 + ], + "IO": "BG4452", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2111) ", + "KENNZEICHNUNG": "=A01+UC0309-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB4450@3": { + "A": "0", + "B": "MB4450", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239864.5, + 152832.4 + ], + "IO": "MB4450", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M2111)", + "KENNZEICHNUNG": "=A01+UC0309-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3242@5": { + "A": "0", + "B": "MB3242", + "C": "10073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217034.5, + 152168.7 + ], + "IO": "MB3242", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 5m", + "SPS": "5" + }, + "MB3242@4": { + "A": "0", + "B": "MB3242", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 378153.0, + 751129.1 + ], + "IO": "MB3242", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M4001)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3242@1": { + "A": "0", + "B": "MB3242", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 341906.1, + 165131.9 + ], + "IO": "MB3242", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 1 (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3246@1": { + "A": "0", + "B": "MB3246", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337327.1, + 167301.0 + ], + "IO": "MB3246", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator, Einfahrt MT-Buffer LS2 (KR-M0101)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG3307@5": { + "A": "0", + "B": "BG3307", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 224520.7, + 150901.3 + ], + "IO": "BG3307", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS CV-M5002)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "5" + }, + "BG3307@3": { + "A": "0", + "B": "BG3307", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204428.4, + 443498.4 + ], + "IO": "BG3307", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2106) ", + "KENNZEICHNUNG": "=A01+UC0302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3307@2": { + "A": "0", + "B": "BG3307", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204500.2, + 293439.4 + ], + "IO": "BG3307", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1106)", + "KENNZEICHNUNG": "=A01+UC0202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3307@5": { + "A": "0", + "B": "MB3307", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225263.2, + 150906.5 + ], + "IO": "MB3307", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "5" + }, + "BG3312@5": { + "A": "0", + "B": "BG3312", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221061.3, + 152212.8 + ], + "IO": "BG3312", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator(ILS-KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "5" + }, + "BG3312@4": { + "A": "0", + "B": "BG3312", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 353870.5, + 728861.9 + ], + "IO": "BG3312", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4004)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3312@1": { + "A": "0", + "B": "BG3312", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 330374.6, + 153905.5 + ], + "IO": "BG3312", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 03 (Block 1.1.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "1.1.03 ", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "MB3312@5": { + "A": "0", + "B": "MB3312", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221061.3, + 152488.0 + ], + "IO": "MB3312", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "5" + }, + "MB3312@1": { + "A": "0", + "B": "MB3312", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 330374.6, + 154648.0 + ], + "IO": "MB3312", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 03 (Block 1.1.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG3246@5": { + "A": "0", + "B": "BG3246", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 218697.2, + 154643.9 + ], + "IO": "BG3246", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M5003)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "5" + }, + "BG3246@4": { + "A": "0", + "B": "BG3246", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 361367.2, + 752187.3 + ], + "IO": "BG3246", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor vor Vario Förderer (ILS-CV M4001)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3246@1": { + "A": "0", + "B": "BG3246", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337327.1, + 167031.0 + ], + "IO": "BG3246", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator, Einfahrt MT-Buffer LS2 (KR-M0101)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG3253@5": { + "A": "0", + "B": "BG3253", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219452.6, + 155555.6 + ], + "IO": "BG3253", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (ILS-CV M5004)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "5" + }, + "BG3253@4": { + "A": "0", + "B": "BG3253", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 361074.8, + 750814.3 + ], + "IO": "BG3253", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4011)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3253@1": { + "A": "0", + "B": "BG3253", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335136.9, + 164829.4 + ], + "IO": "BG3253", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.04 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "1.2.04", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "MB3253@5": { + "A": "0", + "B": "MB3253", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219452.6, + 155830.8 + ], + "IO": "MB3253", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (ILS-CV M5004)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "5" + }, + "MB3253@1": { + "A": "0", + "B": "MB3253", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335483.4, + 166214.3 + ], + "IO": "MB3253", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG3254@5": { + "A": "0", + "B": "BG3254", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219477.1, + 154858.7 + ], + "IO": "BG3254", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M5004)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "5" + }, + "BG3254@1": { + "A": "0", + "B": "BG3254", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334736.9, + 164829.4 + ], + "IO": "BG3254", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.05 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "1.2.05", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3251@5": { + "A": "0", + "B": "BG3251", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219452.6, + 156401.3 + ], + "IO": "BG3251", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M5004)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "5" + }, + "BG3251@1": { + "A": "0", + "B": "BG3251", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 336351.2, + 164519.5 + ], + "IO": "BG3251", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.02 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "1.2.02", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3251@4": { + "A": "0", + "B": "BG3251", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 380629.7, + 750474.8 + ], + "IO": "BG3251", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (AMR ILS-CV M4503) ", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3251@5": { + "A": "0", + "B": "MB3251", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219452.6, + 156676.5 + ], + "IO": "MB3251", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 (ILS-CV M5004)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "5" + }, + "MB3251@1": { + "A": "0", + "B": "MB3251", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337079.8, + 166214.3 + ], + "IO": "MB3251", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG3250@5": { + "A": "0", + "B": "BG3250", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219452.6, + 156994.2 + ], + "IO": "BG3250", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M5003)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "5" + }, + "BG3250@4": { + "A": "0", + "B": "BG3250", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 360632.7, + 750259.0 + ], + "IO": "BG3250", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M4011)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3250@1": { + "A": "0", + "B": "BG3250", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 336751.3, + 164837.6 + ], + "IO": "BG3250", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.01 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "1.2.01", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG3247@5": { + "A": "0", + "B": "BG3247", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219452.6, + 157546.1 + ], + "IO": "BG3247", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M5003)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "5" + }, + "BG3247@3": { + "A": "0", + "B": "BG3247", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187189.2, + 443491.0 + ], + "IO": "BG3247", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2105) ", + "KENNZEICHNUNG": "=A01+UC0301-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3247@2": { + "A": "0", + "B": "BG3247", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187300.2, + 293435.5 + ], + "IO": "BG3247", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1105)", + "KENNZEICHNUNG": "=A01+UC0201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3310@5": { + "A": "0", + "B": "BG3310", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223742.2, + 150901.3 + ], + "IO": "BG3310", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS KR-M5000)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "5" + }, + "BG3310@4": { + "A": "0", + "B": "BG3310", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 354359.4, + 728024.2 + ], + "IO": "BG3310", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (AMR ILS-CV M4004)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3310@1": { + "A": "0", + "B": "BG3310", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331174.2, + 153905.5 + ], + "IO": "BG3310", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 01 (Block 1.1.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "1.1.01 ", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG3257@5": { + "A": "0", + "B": "BG3257", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220121.6, + 152757.5 + ], + "IO": "BG3257", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 4 (ILS-CV M5004)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "5" + }, + "BG3257@1": { + "A": "0", + "B": "BG3257", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331297.8, + 166996.9 + ], + "IO": "BG3257", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator, Einfahrt MT-Buffer LS1 (KR-M0101)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "MB3257@5": { + "A": "0", + "B": "MB3257", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220121.6, + 153026.2 + ], + "IO": "MB3257", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 4 (ILS-CV M5004)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8 Bu-0° 10m", + "SPS": "5" + }, + "MB3257@1": { + "A": "0", + "B": "MB3257", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331297.8, + 167266.9 + ], + "IO": "MB3257", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator, Einfahrt MT-Buffer LS1 (KR-M0101)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG3256@5": { + "A": "0", + "B": "BG3256", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 220121.9, + 153706.0 + ], + "IO": "BG3256", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M5004)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "5" + }, + "BG3256@4": { + "A": "0", + "B": "BG3256", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 380629.7, + 749879.2 + ], + "IO": "BG3256", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M4011)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3321@5": { + "A": "0", + "B": "BG3321", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223630.3, + 153596.9 + ], + "IO": "BG3321", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI2", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": " M12-90° 15m", + "SPS": "5" + }, + "BG3321@4": { + "A": "0", + "B": "BG3321", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356132.3, + 730012.0 + ], + "IO": "BG3321", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator Ausfahrt MPS 3 (AMR ILS-CV M4005)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3321@1": { + "A": "0", + "B": "BG3321", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 336774.2, + 153897.8 + ], + "IO": "BG3321", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 02 (Block 1.2.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "1.2.02", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "BG3367@5": { + "A": "0", + "B": "BG3367", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227659.5, + 153310.7 + ], + "IO": "BG3367", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "5" + }, + "BG3367@4": { + "A": "0", + "B": "BG3367", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358307.0, + 739968.5 + ], + "IO": "BG3367", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 4 (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3367@3": { + "A": "0", + "B": "BG3367", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206540.2, + 443442.8 + ], + "IO": "BG3367", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2107) ", + "KENNZEICHNUNG": "=A01+UC0303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3367@2": { + "A": "0", + "B": "BG3367", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206540.2, + 293439.4 + ], + "IO": "BG3367", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1107)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3381@5": { + "A": "0", + "B": "BG3381", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232043.6, + 153356.9 + ], + "IO": "BG3381", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M5007)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3381@4": { + "A": "0", + "B": "BG3381", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356210.6, + 742000.8 + ], + "IO": "BG3381", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator Ausfahrt MPS 2 (AMR ILS-CV M4007)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3252@5": { + "A": "0", + "B": "BG3252", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219457.2, + 156108.3 + ], + "IO": "BG3252", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M5004)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "5" + }, + "BG3252@4": { + "A": "0", + "B": "BG3252", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 360595.8, + 752169.1 + ], + "IO": "BG3252", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator vor BST (ILS-CV M4001) ", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3252@1": { + "A": "0", + "B": "BG3252", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335537.1, + 164537.2 + ], + "IO": "BG3252", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.03 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI1", + "TEXT-D": "", + "TEXT-E": "1.2.03", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3255@5": { + "A": "0", + "B": "BG3255", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 219465.2, + 154588.1 + ], + "IO": "BG3255", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M5004)", + "KENNZEICHNUNG": "=A01+UC0501-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "5" + }, + "BG3255@4": { + "A": "0", + "B": "BG3255", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 361545.5, + 751087.8 + ], + "IO": "BG3255", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4011)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3313@5": { + "A": "0", + "B": "BG3313", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222265.9, + 151995.4 + ], + "IO": "BG3313", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "5" + }, + "BG3313@4": { + "A": "0", + "B": "BG3313", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 351217.4, + 728296.4 + ], + "IO": "BG3313", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (AMR ILS-CV M4004) MPS 3", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3313@1": { + "A": "0", + "B": "BG3313", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329974.5, + 153905.5 + ], + "IO": "BG3313", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 04 (Block 1.1.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "1.1.04 ", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "MB3313@5": { + "A": "0", + "B": "MB3313", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222261.4, + 151729.8 + ], + "IO": "MB3313", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "5" + }, + "MB3313@1": { + "A": "0", + "B": "MB3313", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329974.5, + 154648.0 + ], + "IO": "MB3313", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 04 (Block 1.1.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG3316@5": { + "A": "0", + "B": "BG3316", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221057.7, + 155285.6 + ], + "IO": "BG3316", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": " M12 Bu-0° 15m", + "SPS": "5" + }, + "BG3316@4": { + "A": "0", + "B": "BG3316", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 353380.7, + 728299.8 + ], + "IO": "BG3316", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Position MPS 3 (AMR ILS-CV M4004)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3316@5": { + "A": "0", + "B": "MB3316", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221057.7, + 155560.8 + ], + "IO": "MB3316", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8 Bu-0° 15m", + "SPS": "5" + }, + "BG3315@5": { + "A": "0", + "B": "BG3315", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221062.2, + 154968.4 + ], + "IO": "BG3315", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": " M12 Bu-90° 15m", + "SPS": "5" + }, + "BG3315@4": { + "A": "0", + "B": "BG3315", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 350450.1, + 728297.6 + ], + "IO": "BG3315", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4005) MPS 3", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3315@1": { + "A": "0", + "B": "BG3315", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 333680.0, + 153895.6 + ], + "IO": "BG3315", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "BG3320@5": { + "A": "0", + "B": "BG3320", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221062.2, + 156512.8 + ], + "IO": "BG3320", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": " M12 Bu-90° 15m", + "SPS": "5" + }, + "BG3320@4": { + "A": "0", + "B": "BG3320", + "C": "10073710081010151939", + "ARTINR": "819434306", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355126.8, + 730017.2 + ], + "IO": "BG3320", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (AMR ILS-CV M4005)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3320@1": { + "A": "0", + "B": "BG3320", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337174.2, + 153897.8 + ], + "IO": "BG3320", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 01 (Block 1.2.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "1.2.01", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "BG3317@5": { + "A": "0", + "B": "BG3317", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221074.1, + 156205.8 + ], + "IO": "BG3317", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": " M12 Bu-90° 15m", + "SPS": "5" + }, + "BG3317@4": { + "A": "0", + "B": "BG3317", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 354258.5, + 730017.2 + ], + "IO": "BG3317", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (AMR ILS-CV M4005)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3314@5": { + "A": "0", + "B": "BG3314", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221057.7, + 154411.3 + ], + "IO": "BG3314", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": " M12 Bu-0° 15m", + "SPS": "5" + }, + "BG3314@4": { + "A": "0", + "B": "BG3314", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 349070.3, + 728587.0 + ], + "IO": "BG3314", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Entladeposition MPS 3 (AMR ILS-CV M4005)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3314@1": { + "A": "0", + "B": "BG3314", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329574.6, + 153905.5 + ], + "IO": "BG3314", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 05 (Block 1.1.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "1.1.05", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "MB3314@5": { + "A": "0", + "B": "MB3314", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 221057.7, + 154686.5 + ], + "IO": "MB3314", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8 Bu-0° 15m", + "SPS": "5" + }, + "MB3314@1": { + "A": "0", + "B": "MB3314", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329574.6, + 154648.0 + ], + "IO": "MB3314", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 05 (Block 1.1.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG3324@5": { + "A": "0", + "B": "BG3324", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 222261.4, + 151209.9 + ], + "IO": "BG3324", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "5" + }, + "BG3324@1": { + "A": "0", + "B": "BG3324", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334778.9, + 153896.8 + ], + "IO": "BG3324", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 05 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "1.2.05 ", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "BG3324@4": { + "A": "0", + "B": "BG3324", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 349648.4, + 728259.4 + ], + "IO": "BG3324", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Position MPS 3 (AMR ILS-CV M4005)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3322@5": { + "A": "0", + "B": "BG3322", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223630.3, + 152587.2 + ], + "IO": "BG3322", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 15m", + "SPS": "5" + }, + "BG3322@4": { + "A": "0", + "B": "BG3322", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356441.4, + 730594.7 + ], + "IO": "BG3322", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor Ausfahrt MPS 03 (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3322@1": { + "A": "0", + "B": "BG3322", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335578.9, + 153896.8 + ], + "IO": "BG3322", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 03 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "1.2.03", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "MB3322@5": { + "A": "0", + "B": "MB3322", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223630.3, + 152862.4 + ], + "IO": "MB3322", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M5005)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 15m", + "SPS": "5" + }, + "MB3322@1": { + "A": "0", + "B": "MB3322", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335578.9, + 154639.3 + ], + "IO": "MB3322", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 03 (Block 1.2.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 5m", + "SPS": "1" + }, + "BG3323@5": { + "A": "0", + "B": "BG3323", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 223919.9, + 151725.0 + ], + "IO": "BG3323", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-KR M5002)", + "KENNZEICHNUNG": "=A01+UC0502-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": " M12-0° 15m", + "SPS": "5" + }, + "BG3323@1": { + "A": "0", + "B": "BG3323", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335178.9, + 153896.8 + ], + "IO": "BG3323", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 04 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "1.2.04", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1" + }, + "BG3366@5": { + "A": "0", + "B": "BG3366", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225303.1, + 156585.4 + ], + "IO": "BG3366", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3365@5": { + "A": "0", + "B": "BG3365", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225314.9, + 156315.9 + ], + "IO": "BG3365", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3365@3": { + "A": "0", + "B": "BG3365", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205915.4, + 440597.0 + ], + "IO": "BG3365", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS-KR-M2104)", + "KENNZEICHNUNG": "=A01+UC0303-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3365@2": { + "A": "0", + "B": "BG3365", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206828.4, + 290580.6 + ], + "IO": "BG3365", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS-KR-M1104)", + "KENNZEICHNUNG": "=A01+UC0203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3362@5": { + "A": "0", + "B": "MB3362", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 225298.5, + 155048.8 + ], + "IO": "MB3362", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3362@4": { + "A": "0", + "B": "MB3362", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358395.6, + 737414.9 + ], + "IO": "MB3362", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3370@5": { + "A": "0", + "B": "BG3370", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227659.5, + 152272.0 + ], + "IO": "BG3370", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "5" + }, + "BG3370@4": { + "A": "0", + "B": "BG3370", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 354359.3, + 740059.4 + ], + "IO": "BG3370", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (AMR ILS-CV M4006)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3370@5": { + "A": "0", + "B": "MB3370", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227659.5, + 152547.2 + ], + "IO": "MB3370", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M5006)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "5" + }, + "MB3370@4": { + "A": "0", + "B": "MB3370", + "C": "10073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 354359.4, + 740317.3 + ], + "IO": "MB3370", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (AMR ILS-CV M4006)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3371@5": { + "A": "0", + "B": "BG3371", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227664.1, + 151954.8 + ], + "IO": "BG3371", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-KR M5002)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "5" + }, + "BG3371@4": { + "A": "0", + "B": "BG3371", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356313.6, + 740885.8 + ], + "IO": "BG3371", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 3 (AMR ILS-CV M4006)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3372@5": { + "A": "0", + "B": "BG3372", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229602.9, + 152190.6 + ], + "IO": "BG3372", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator(ILS-KR-M0500)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3372@4": { + "A": "0", + "B": "BG3372", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 353864.3, + 740884.8 + ], + "IO": "BG3372", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4006)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3372@5": { + "A": "0", + "B": "MB3372", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229602.9, + 152465.9 + ], + "IO": "MB3372", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-KR-M0500)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3373@5": { + "A": "0", + "B": "BG3373", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230839.8, + 151995.4 + ], + "IO": "BG3373", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M5007", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3373@4": { + "A": "0", + "B": "BG3373", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 351207.8, + 740303.0 + ], + "IO": "BG3373", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (AMR ILS-CV M4006)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3373@5": { + "A": "0", + "B": "MB3373", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230835.3, + 151729.8 + ], + "IO": "MB3373", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M5007", + "KENNZEICHNUNG": "=A01+UC0503-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3376@5": { + "A": "0", + "B": "BG3376", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229607.8, + 155661.1 + ], + "IO": "BG3376", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 3 (ILS-CV M5007", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3376@4": { + "A": "0", + "B": "BG3376", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 353389.1, + 740318.9 + ], + "IO": "BG3376", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Position MPS 2 (AMR ILS-CV M4006)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3376@5": { + "A": "0", + "B": "MB3376", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229607.8, + 155936.3 + ], + "IO": "MB3376", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 3 (ILS-CV M5007", + "KENNZEICHNUNG": "=A01+UC0503-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3375@5": { + "A": "0", + "B": "BG3375", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229612.4, + 155343.9 + ], + "IO": "BG3375", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-CV M5007)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3375@4": { + "A": "0", + "B": "BG3375", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 350434.2, + 740309.8 + ], + "IO": "BG3375", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4007) MPS 2", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3380@5": { + "A": "0", + "B": "BG3380", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229612.4, + 156585.4 + ], + "IO": "BG3380", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M5007)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3380@4": { + "A": "0", + "B": "BG3380", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355383.5, + 742006.0 + ], + "IO": "BG3380", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (AMR ILS-CV M4007)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3377@5": { + "A": "0", + "B": "BG3377", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229624.2, + 156300.1 + ], + "IO": "BG3377", + "ID": "", + "VERW": "Finger in Position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M5007)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3377@4": { + "A": "0", + "B": "BG3377", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 354602.4, + 742009.9 + ], + "IO": "BG3377", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (AMR ILS-CV M4007)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3374@5": { + "A": "0", + "B": "BG3374", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229607.8, + 154786.8 + ], + "IO": "BG3374", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M5007)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3374@4": { + "A": "0", + "B": "BG3374", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 349074.0, + 740611.0 + ], + "IO": "BG3374", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT IN Entladeposition MPS- (AMR ILS-CV M4007)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3374@5": { + "A": "0", + "B": "MB3374", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 229607.8, + 155062.0 + ], + "IO": "MB3374", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M5007", + "KENNZEICHNUNG": "=A01+UC0503-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3382@5": { + "A": "0", + "B": "BG3382", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232043.6, + 152272.0 + ], + "IO": "BG3382", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M5007)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3382@4": { + "A": "0", + "B": "BG3382", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356441.4, + 742619.7 + ], + "IO": "BG3382", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor Ausfahrt MPS 02 (AMR ILS-KR M04003)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3382@5": { + "A": "0", + "B": "MB3382", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232043.6, + 152547.2 + ], + "IO": "MB3382", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M5007)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3383@5": { + "A": "0", + "B": "BG3383", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232048.2, + 151954.8 + ], + "IO": "BG3383", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Staumelder, Einfahrt (ILS-KR M5002)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3383@4": { + "A": "0", + "B": "BG3383", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 357632.4, + 741620.4 + ], + "IO": "BG3383", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3430@5": { + "A": "0", + "B": "MB3430", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 236615.2, + 152546.9 + ], + "IO": "MB3430", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3430@4": { + "A": "0", + "B": "MB3430", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356126.6, + 749033.2 + ], + "IO": "MB3430", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator vor MPS 1 (AMR KR-M4003)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3422@5": { + "A": "0", + "B": "MB3422", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 234162.4, + 155049.3 + ], + "IO": "MB3422", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M5008)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "MB3433@5": { + "A": "0", + "B": "MB3433", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 238172.1, + 152307.5 + ], + "IO": "MB3433", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3080@1": { + "A": "0", + "B": "BG3080", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 380643.1, + 751272.8 + ], + "IO": "BG3080", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 2 (ILS-CV M4503)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI02", + "TEXT-D": "=A01+UC1102", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3081@1": { + "A": "0", + "B": "BG3081", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 380646.1, + 751861.1 + ], + "IO": "BG3081", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position in Separator 2 (ILS-CV M4503) ", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI02", + "TEXT-D": "=A01+UC1102", + "TEXT-E": "=A01+UC1102", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3311@4": { + "A": "0", + "B": "BG3311", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356303.6, + 728860.8 + ], + "IO": "BG3311", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (AMR ILS-CV M4004)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3311@1": { + "A": "0", + "B": "BG3311", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 330772.7, + 153905.5 + ], + "IO": "BG3311", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator 02 (Block 1.1.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI1", + "TEXT-D": "", + "TEXT-E": "1.1.02", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG3386@4": { + "A": "0", + "B": "BG3386", + "C": "10073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/11MM/150KABEL-ST-M11", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358787.8, + 741472.9 + ], + "IO": "BG3386", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (AMR ILS-CV M4002)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3387@4": { + "A": "0", + "B": "BG3387", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358794.0, + 742511.8 + ], + "IO": "BG3387", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor 3 (AMR ILS-CV M4002)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3321@4": { + "A": "0", + "B": "MB3321", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356132.3, + 730282.0 + ], + "IO": "MB3321", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 2 Ausfahrt MPS 3 (AMR ILS-CV M4005)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3321@1": { + "A": "0", + "B": "MB3321", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 336774.2, + 154640.3 + ], + "IO": "MB3321", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 02 (Block 1.2.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 5m", + "SPS": "1" + }, + "MB3363@4": { + "A": "0", + "B": "MB3363", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356336.6, + 739435.7 + ], + "IO": "MB3363", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 5 (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3080@1": { + "A": "0", + "B": "MB3080", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 380643.1, + 751542.8 + ], + "IO": "MB3080", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M4503)", + "KENNZEICHNUNG": "=A01+UC1102-KF1DQ02", + "TEXT-D": "=A01+UC1102", + "TEXT-E": "=A01+UC1102", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "MB3252@4": { + "A": "0", + "B": "MB3252", + "C": "10073710081010151939", + "ARTINR": "722001306", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 20m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 360595.8, + 752439.1 + ], + "IO": "MB3252", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator vor BST (ILS-CV M4001) ", + "KENNZEICHNUNG": "=A01+UC0401-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3252@1": { + "A": "0", + "B": "MB3252", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335884.1, + 166214.3 + ], + "IO": "MB3252", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3310@4": { + "A": "0", + "B": "MB3310", + "C": "10073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 354359.4, + 728292.9 + ], + "IO": "MB3310", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (AMR ILS-CV M4004)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3310@1": { + "A": "0", + "B": "MB3310", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331174.2, + 154648.0 + ], + "IO": "MB3310", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 01 (Block 1.1.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3386@4": { + "A": "0", + "B": "MB3386", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 358787.8, + 740730.4 + ], + "IO": "MB3386", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (AMR ILS-CV M4002)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3366@4": { + "A": "0", + "B": "MB3366", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356357.7, + 740051.9 + ], + "IO": "MB3366", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3381@4": { + "A": "0", + "B": "MB3381", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 356210.6, + 742270.8 + ], + "IO": "MB3381", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator Ausfahrt MPS 2 (AMR ILS-CV M4007)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3435@4": { + "A": "0", + "B": "MB3435", + "C": "10073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 355961.3, + 753131.8 + ], + "IO": "MB3435", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator(AMR KR-M4003)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3383@4": { + "A": "0", + "B": "MB3383", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 357632.4, + 741890.4 + ], + "IO": "MB3383", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (AMR ILS-KR M4003)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3444@4": { + "A": "0", + "B": "BG3444", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 349083.1, + 750135.1 + ], + "IO": "BG3444", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT IN Entladeposition MPS- (AMR ILS-CV M4009)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3447@4": { + "A": "0", + "B": "BG3447", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 354293.4, + 751447.4 + ], + "IO": "BG3447", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (AMR ILS-CV M4009)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3250@4": { + "A": "0", + "B": "MB3250", + "C": "10073710081010151939", + "ARTINR": "722001306", + "BESCHR": "Verb.-Leitung M11 St-0°/ M8 Bu-0° PUR UL/CSA 20m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 360632.7, + 750529.0 + ], + "IO": "MB3250", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M4011)", + "KENNZEICHNUNG": "=A01+UC0401-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3250@1": { + "A": "0", + "B": "MB3250", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337479.8, + 166214.3 + ], + "IO": "MB3250", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG3082@1": { + "A": "0", + "B": "BG3082", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 380646.1, + 752131.1 + ], + "IO": "BG3082", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4503) ", + "KENNZEICHNUNG": "=A01+UC1102-KF1DI02", + "TEXT-D": "=A01+UC1102", + "TEXT-E": "=A01+UC1102", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3446@4": { + "A": "0", + "B": "BG3446", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 353385.8, + 749826.2 + ], + "IO": "BG3446", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Position MPS 1 (AMR ILS-CV M4008)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3907@3": { + "A": "0", + "B": "BG3907", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 423945.4 + ], + "IO": "BG3907", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2208) ", + "KENNZEICHNUNG": "=A01+UC3204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3907@2": { + "A": "0", + "B": "BG3907", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227501.9, + 273949.2 + ], + "IO": "BG3907", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1208) ", + "KENNZEICHNUNG": "=A01+UC2204-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3847@3": { + "A": "0", + "B": "BG3847", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206541.8, + 423953.6 + ], + "IO": "BG3847", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2207) ", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3847@2": { + "A": "0", + "B": "BG3847", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206541.8, + 274008.8 + ], + "IO": "BG3847", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1207) ", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3787@3": { + "A": "0", + "B": "BG3787", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204390.8, + 423953.4 + ], + "IO": "BG3787", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2206) ", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3787@2": { + "A": "0", + "B": "BG3787", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204502.1, + 273985.6 + ], + "IO": "BG3787", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1206) ", + "KENNZEICHNUNG": "=A01+UC3202-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3727@2": { + "A": "0", + "B": "BG3727", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187300.2, + 273960.1 + ], + "IO": "BG3727", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1205) ", + "KENNZEICHNUNG": "=A01+UC2201-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4027@3": { + "A": "0", + "B": "BG4027", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204379.5, + 415211.0 + ], + "IO": "BG4027", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2206) ", + "KENNZEICHNUNG": "=A01+UC3206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4027@2": { + "A": "0", + "B": "BG4027", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204381.8, + 265224.5 + ], + "IO": "BG4027", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1306) ", + "KENNZEICHNUNG": "=A01+UC2206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3967@3": { + "A": "0", + "B": "BG3967", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187181.5, + 415224.0 + ], + "IO": "BG3967", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2305) ", + "KENNZEICHNUNG": "=A01+UC3205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3967@2": { + "A": "0", + "B": "BG3967", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 187181.8, + 265215.4 + ], + "IO": "BG3967", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1305)", + "KENNZEICHNUNG": "=A01+UC2205-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4087@3": { + "A": "0", + "B": "BG4087", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206550.4, + 415218.8 + ], + "IO": "BG4087", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2305) ", + "KENNZEICHNUNG": "=A01+UC3207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4087@2": { + "A": "0", + "B": "BG4087", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206438.6, + 265199.0 + ], + "IO": "BG4087", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1307) ", + "KENNZEICHNUNG": "=A01+UC2207-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4147@3": { + "A": "0", + "B": "BG4147", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227440.0, + 415224.5 + ], + "IO": "BG4147", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M2308) ", + "KENNZEICHNUNG": "=A01+UC3208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4147@2": { + "A": "0", + "B": "BG4147", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 227440.0, + 265220.8 + ], + "IO": "BG4147", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M1308) ", + "KENNZEICHNUNG": "=A01+UC2208-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4502@2": { + "A": "0", + "B": "BG4502", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 242272.2, + 288880.9 + ], + "IO": "BG4502", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 10 (KR-M1100) ", + "KENNZEICHNUNG": "=A01+UC0210-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4533@2": { + "A": "0", + "B": "BG4533", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 245925.1, + 288744.2 + ], + "IO": "BG4533", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4701)", + "KENNZEICHNUNG": "=A01+UC0211-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3263@1": { + "A": "0", + "B": "BG3263", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329551.2, + 164939.4 + ], + "IO": "BG3263", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.04 (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "1.1.04 ", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3264@1": { + "A": "0", + "B": "BG3264", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329151.2, + 164939.4 + ], + "IO": "BG3264", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor Str.05 (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI2", + "TEXT-D": "", + "TEXT-E": "1.1.05 ", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "MA0057@1": { + "A": "0", + "B": "MA0057", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 341970.0, + 163529.3 + ], + "IO": "MA0057", + "ID": "9999", + "VERW": "CV-M0100_0,75", + "BEZEICHNUNG": "Motor MA0057 ILS-CV M0100 EMPTY MT", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor MA0057", + "TEXT-E": "Motor MA0057", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BG3295@1": { + "A": "0", + "B": "BG3295", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340343.6, + 159168.0 + ], + "IO": "BG3295", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": " M12-0° 20m", + "SPS": "1" + }, + "BG3025@1": { + "A": "0", + "B": "BG3025", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 345082.0, + 154417.2 + ], + "IO": "BG3025", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (ILS-CV M4104)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1 ", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 50m", + "SPS": "1" + }, + "BG3027@1": { + "A": "0", + "B": "BG3027", + "C": "20073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage Vario-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 345084.9, + 155398.4 + ], + "IO": "BG3027", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (ILS-CV M4104)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1 ", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 50m", + "SPS": "1" + }, + "BG3026@1": { + "A": "0", + "B": "BG3026", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 345082.5, + 155743.7 + ], + "IO": "BG3026", + "ID": "", + "VERW": "MT in Position", + "BEZEICHNUNG": "MT in Position (ILS-CV M4104)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DI1 ", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 50m", + "SPS": "1" + }, + "BG3294@1": { + "A": "0", + "B": "BG3294", + "C": "20073710081010151939", + "ARTINR": "829434306", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340352.5, + 160860.2 + ], + "IO": "BG3294", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV M0110)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": " M12-90° 15m", + "SPS": "1" + }, + "BG3293@1": { + "A": "0", + "B": "BG3293", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340352.5, + 161670.2 + ], + "IO": "BG3293", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (ILS-CV M0110)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "Förderer voll", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": " M12-90° 15m", + "SPS": "1" + }, + "BG3325@1": { + "A": "0", + "B": "BG3325", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340063.7, + 153903.2 + ], + "IO": "BG3325", + "ID": "", + "VERW": "In sep", + "BEZEICHNUNG": "in Separator (Block 1.2.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1" + }, + "BG3325@4": { + "A": "0", + "B": "BG3325", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 349115.1, + 729620.8 + ], + "IO": "BG3325", + "ID": "", + "VERW": "MT unloaded", + "BEZEICHNUNG": "MT ist entladen MPS 3 (AMR ILS-CV M4005)", + "KENNZEICHNUNG": "=A01+UC0402-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "MB3254@1": { + "A": "0", + "B": "MB3254", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335084.1, + 166214.3 + ], + "IO": "MB3254", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.2)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3261@1": { + "A": "0", + "B": "MB3261", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331074.7, + 166214.3 + ], + "IO": "MB3261", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3262@1": { + "A": "0", + "B": "MB3262", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 330679.6, + 166214.3 + ], + "IO": "MB3262", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3264@1": { + "A": "0", + "B": "MB3264", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329842.2, + 166214.3 + ], + "IO": "MB3264", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3311@1": { + "A": "0", + "B": "MB3311", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 330772.7, + 154648.0 + ], + "IO": "MB3311", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 02 (Block 1.1.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3323@1": { + "A": "0", + "B": "MB3323", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335178.9, + 154639.3 + ], + "IO": "MB3323", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 04 (Block 1.2.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 5m", + "SPS": "1" + }, + "MB3324@1": { + "A": "0", + "B": "MB3324", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334778.9, + 154639.3 + ], + "IO": "MB3324", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 05 (Block 1.2.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 5m", + "SPS": "1" + }, + "MB3320@1": { + "A": "0", + "B": "MB3320", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 337174.2, + 154640.3 + ], + "IO": "MB3320", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator 01 (Block 1.2.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 5m", + "SPS": "1" + }, + "MB3315@1": { + "A": "0", + "B": "MB3315", + "C": "20073710081010151939", + "ARTINR": "722001303", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 5m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 333680.0, + 154638.1 + ], + "IO": "MB3315", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 5m", + "SPS": "1" + }, + "MB3295@1": { + "A": "0", + "B": "MB3295", + "C": "20073710081010151939", + "ARTINR": "722001306", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 20m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340343.6, + 159438.0 + ], + "IO": "MB3295", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 20m", + "SPS": "1" + }, + "MB3025@1": { + "A": "0", + "B": "MB3025", + "C": "20073710081010151939", + "ARTINR": "722001312", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 50m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 345082.0, + 154687.2 + ], + "IO": "MB3025", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (ILS-CV M4104)", + "KENNZEICHNUNG": "=A01+UC1101-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 50m", + "SPS": "1" + }, + "MB3263@1": { + "A": "0", + "B": "MB3263", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 330279.8, + 166214.3 + ], + "IO": "MB3263", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig Str.1 (Block 1.1)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "MB3325@1": { + "A": "0", + "B": "MB3325", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340063.7, + 154645.7 + ], + "IO": "MB3325", + "ID": "", + "VERW": "Sep", + "BEZEICHNUNG": "Separator (Block 1.2.)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M8-0° 10m", + "SPS": "1" + }, + "BG3296@1": { + "A": "0", + "B": "BG3296", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 340352.5, + 159713.2 + ], + "IO": "BG3296", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Stausensor (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0101-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": " M12-90° 20m", + "SPS": "1" + }, + "BG3357@1": { + "A": "0", + "B": "BG3357", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 341041.2, + 151276.3 + ], + "IO": "BG3357", + "ID": "", + "VERW": "End measurement", + "BEZEICHNUNG": "Verlassensensor Längenmessung (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 20m", + "SPS": "1" + }, + "BG3355@1": { + "A": "0", + "B": "BG3355", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 341041.2, + 151816.3 + ], + "IO": "BG3355", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Längenabfrage Grenze lang (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "Teil lang", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3354@1": { + "A": "0", + "B": "BG3354", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 341041.2, + 152086.3 + ], + "IO": "BG3354", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Längenabfrage Grenze kurz (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "Teil vorhanden", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3356@1": { + "A": "0", + "B": "BG3356", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 341041.2, + 151546.3 + ], + "IO": "BG3356", + "ID": "", + "VERW": "Jam detector", + "BEZEICHNUNG": "Längenabfrage Grenze zu lang (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0102-KF1DI3", + "TEXT-D": "", + "TEXT-E": "Teil zu lang", + "TEXT-ES": "", + "TEXT-F": "M12-90° 10m", + "SPS": "1" + }, + "BG3443@4": { + "A": "0", + "B": "BG3443", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 351222.8, + 749801.3 + ], + "IO": "BG3443", + "ID": "", + "VERW": "conveyor full", + "BEZEICHNUNG": "Sensor Förderer voll (AMR ILS-CV M4008)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3443@1": { + "A": "0", + "B": "BG3443", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 237453.9, + 150048.0 + ], + "IO": "BG3443", + "ID": "", + "VERW": "End measurement", + "BEZEICHNUNG": "Verlassensensor Längenmessung (ILS-CV)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 20m", + "SPS": "1" + }, + "BG3445@4": { + "A": "0", + "B": "BG3445", + "C": "10073710081010151939", + "ARTINR": "200000375", + "BESCHR": "Halter mit Sensor für Abfrage VARIO-TEF Finger", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 350449.8, + 749774.4 + ], + "IO": "BG3445", + "ID": "", + "VERW": "Finger in position", + "BEZEICHNUNG": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4009)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3384@4": { + "A": "0", + "B": "BG3384", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 349648.4, + 740289.4 + ], + "IO": "BG3384", + "ID": "", + "VERW": "MT in position", + "BEZEICHNUNG": "MT in Position MPS 2 (AMR ILS-CV M4007)", + "KENNZEICHNUNG": "=A01+UC0403-KF1DI2 ", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3384@5": { + "A": "0", + "B": "BG3384", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226560.5, + 151239.3 + ], + "IO": "BG3384", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "5" + }, + "BG3385@4": { + "A": "0", + "B": "BG3385", + "C": "10073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 349115.1, + 741650.8 + ], + "IO": "BG3385", + "ID": "", + "VERW": "MT unloaded", + "BEZEICHNUNG": "MT ist entladen MPS 2 (AMR ILS-CV M4007)", + "KENNZEICHNUNG": "=A01+UC0404-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BG3385@5": { + "A": "0", + "B": "BG3385", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 230839.7, + 151239.3 + ], + "IO": "BG3385", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0503-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "5" + }, + "BG3845@3": { + "A": "0", + "B": "BG3845", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206544.9, + 421068.8 + ], + "IO": "BG3845", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (KR-M2204)", + "KENNZEICHNUNG": "=A01+UC3203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3845@2": { + "A": "0", + "B": "BG3845", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205932.8, + 270789.9 + ], + "IO": "BG3845", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS-CV-M1204)", + "KENNZEICHNUNG": "=A01+UC2203-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4341@2": { + "A": "0", + "B": "BG4341", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 206443.3, + 247874.5 + ], + "IO": "BG4341", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor 2 (KR-M1304)", + "KENNZEICHNUNG": "=A01+UC2303-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3061@3": { + "A": "0", + "B": "MB3061", + "C": "20073710081010151939", + "ARTINR": "722001304", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 10m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205054.1, + 459465.9 + ], + "IO": "MB3061", + "ID": "MB3090", + "VERW": "Switch left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links (Einlagerkreisel Block 1, KR-2101-2202)", + "KENNZEICHNUNG": "=A01+UC3102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3061@2": { + "A": "0", + "B": "MB3061", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 205045.1, + 309470.4 + ], + "IO": "MB3061", + "ID": "", + "VERW": "Switch left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links (Einlagerkreisel Block 1, KR-1101-1102)", + "KENNZEICHNUNG": "=A01+UC2102-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "MB3541@3": { + "A": "0", + "B": "MB3541", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204993.4, + 438559.9 + ], + "IO": "MB3541", + "ID": "", + "VERW": "Switch left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links (Einlagerkreisel Block 2, KR-2201-2202)", + "KENNZEICHNUNG": "=A01+UC0306-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "MB3541@2": { + "A": "0", + "B": "MB3541", + "C": "20073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204963.4, + 288460.1 + ], + "IO": "MB3541", + "ID": "", + "VERW": "Switch left", + "BEZEICHNUNG": "Rad-Rad-Weiche Links (Einlagerkreisel Block 1, KR-1201-1202)", + "KENNZEICHNUNG": "=A01+UC0206-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3437@5": { + "A": "0", + "B": "BG3437", + "C": "10073670081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 235410.3, + 151239.3 + ], + "IO": "BG3437", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor (ILS KR-M5002)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-90° 15m", + "SPS": "5" + }, + "MB3436@5": { + "A": "0", + "B": "MB3436", + "C": "10073710081010151939", + "ARTINR": "722001305", + "BESCHR": "Verb.-Leitung M12 St-0°/ M8 Bu-0° PUR UL/CSA 15m", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 239592.0, + 151728.5 + ], + "IO": "MB3436", + "ID": "", + "VERW": "ES brunch", + "BEZEICHNUNG": "AE Abzweig (ILS-CV M2111)", + "KENNZEICHNUNG": "=A01+UC0504-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BG3140@3": { + "A": "0", + "B": "BG3140", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226360.6, + 458836.2 + ], + "IO": "BG3140", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor MT vor Pinband (KR-M2102 Block 2.1.3)", + "KENNZEICHNUNG": "=A01+UC3103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3553@3": { + "A": "0", + "B": "BG3553", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188668.8, + 438122.5 + ], + "IO": "BG3553", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor MT vor Pinband (KR-M2201) Block 2.2.2", + "KENNZEICHNUNG": "=A01+UC0306-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3553@2": { + "A": "0", + "B": "BG3553", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188668.8, + 288122.5 + ], + "IO": "BG3553", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor MT vor Pinband (KR-K1201) Block 1.2.2", + "KENNZEICHNUNG": "=A01+UC0206-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3625@3": { + "A": "0", + "B": "BG3625", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226369.5, + 437829.1 + ], + "IO": "BG3625", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor MT vor Pinband (KR-M2202) Block 2.2.3", + "KENNZEICHNUNG": "=A01+UC0307-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG3625@2": { + "A": "0", + "B": "BG3625", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226369.5, + 287829.1 + ], + "IO": "BG3625", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor MT vor Pinband (KR-K1203) Block 1.2.3", + "KENNZEICHNUNG": "=A01+UC0207-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG4375@3": { + "A": "0", + "B": "BG4375", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226369.5, + 399160.8 + ], + "IO": "BG4375", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor MT vor Pinband (KR-K2304) Block 2.3.3)", + "KENNZEICHNUNG": "=A01+UC3303-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4273@3": { + "A": "0", + "B": "BG4273", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188610.7, + 398854.0 + ], + "IO": "BG4273", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor MT vor Pinband (KR-K2303) Block 2.3.2", + "KENNZEICHNUNG": "=A01+UC3302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BG4273@2": { + "A": "0", + "B": "BG4273", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 188610.7, + 248854.0 + ], + "IO": "BG4273", + "ID": "", + "VERW": "Jam detector (LP)", + "BEZEICHNUNG": "Stausensor MT vor Pinband (KR-K1303) Block 1.3.2", + "KENNZEICHNUNG": "=A01+UC2302-KF1DI1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BG3142@2": { + "A": "0", + "B": "BG3142", + "C": "20073710081010151939", + "ARTINR": "200000248", + "BESCHR": "STAUABFRAGE[LT] KPL.", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 226360.6, + 308836.2 + ], + "IO": "BG3142", + "ID": "", + "VERW": "jam detector (LP)", + "BEZEICHNUNG": "Stausensor MT vor Pinband (KR-M1102 Block 1.1.3)", + "KENNZEICHNUNG": "=A01+UC2103-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BP0004@1": { + "A": "0", + "B": "BP0004", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 328638.1, + 149936.1 + ], + "IO": "BP0004", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BP0004@5": { + "A": "0", + "B": "BP0004", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216203.7, + 156730.0 + ], + "IO": "BP0004", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UH05-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5" + }, + "BP0004@4": { + "A": "0", + "B": "BP0004", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 359592.2, + 722561.0 + ], + "IO": "BP0004", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UH04-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4" + }, + "BP0004@2": { + "A": "0", + "B": "BP0004", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250893.4, + 289544.3 + ], + "IO": "BP0004", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BP0004@3": { + "A": "0", + "B": "BP0004", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202961.4, + 439216.6 + ], + "IO": "BP0004", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BP0107@3": { + "A": "0", + "B": "BP0107", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204336.6, + 460237.6 + ], + "IO": "BP0107", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UC031-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BP0107@2": { + "A": "0", + "B": "BP0107", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 247624.1, + 307156.1 + ], + "IO": "BP0107", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UC021-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BP0107@1": { + "A": "0", + "B": "BP0107", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334538.1, + 450099.7 + ], + "IO": "BP0107", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UC011-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1" + }, + "BP0167@3": { + "A": "0", + "B": "BP0167", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215427.0, + 420034.4 + ], + "IO": "BP0167", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BP0167@2": { + "A": "0", + "B": "BP0167", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250872.2, + 269451.5 + ], + "IO": "BP0167", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UC022-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + }, + "BP0227@3": { + "A": "0", + "B": "BP0227", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204321.3, + 397561.2 + ], + "IO": "BP0227", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UC033-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3" + }, + "BP0227@2": { + "A": "0", + "B": "BP0227", + "C": "20073710081010151939", + "ARTINR": "929012655", + "BESCHR": "DRUCKSCHALTER PM1-M3-G014", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 245871.9, + 248229.8 + ], + "IO": "BP0227", + "ID": "9999", + "VERW": "pressure switch", + "BEZEICHNUNG": "Druckschalter Druckluft OK", + "KENNZEICHNUNG": "=A01+UC023-KF1DI1", + "TEXT-D": "Druckluft OK", + "TEXT-E": "Compressed air OK", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2" + } + }, + "schaltschrank_elemente": { + "SF0086@3": { + "IO": "SF0086", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0312", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 275042.4, + 449559.4 + ] + }, + "SF0087@3": { + "IO": "SF0087", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0312", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 275042.4, + 449289.4 + ] + }, + "SF0130@1": { + "IO": "SF0130", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ1105", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 299080.7, + 450481.9 + ] + }, + "SF0131@1": { + "IO": "SF0131", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ1105", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 299080.7, + 450211.9 + ] + }, + "SF0126@1": { + "IO": "SF0126", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ1104", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 313036.3, + 450452.7 + ] + }, + "SF0124@1": { + "IO": "SF0124", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ1103", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328664.8, + 450445.2 + ] + }, + "SF0125@1": { + "IO": "SF0125", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ1103", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328664.8, + 450175.2 + ] + }, + "SF0122@1": { + "IO": "SF0122", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ1102", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 353085.6, + 455195.0 + ] + }, + "SF0123@1": { + "IO": "SF0123", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ1102", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 353085.6, + 454925.0 + ] + }, + "SF0712@1": { + "IO": "SF0712", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ1102", + "KENNZEICHNUNG": "=A01+UC011-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 353085.6, + 454624.8 + ] + }, + "SF0716@1": { + "IO": "SF0716", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ1102", + "KENNZEICHNUNG": "=A01+UC011-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 353085.6, + 454354.8 + ] + }, + "FC0090@3": { + "IO": "FC0090", + "ID": "", + "VERW": "MS FC0090", + "BEZEICHNUNG": "MSS ausgelöst FC0090 (CV-M4102)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI5", + "TEXT-D": "MSS ausgelöst FC0090", + "TEXT-E": "MPCB triggered FC0090", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 255200.1, + 427671.4 + ] + }, + "FC0091@3": { + "IO": "FC0091", + "ID": "", + "VERW": "MS FC0091", + "BEZEICHNUNG": "MSS ausgelöst FC0091 (CV-M4202)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI5", + "TEXT-D": "MSS ausgelöst FC0091", + "TEXT-E": "MPCB triggered FC0091", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 255200.1, + 427401.4 + ] + }, + "FC0093@3": { + "IO": "FC0093", + "ID": "", + "VERW": "MS FC0093", + "BEZEICHNUNG": "MSS ausgelöst FC0093 (CV-M4401)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI5", + "TEXT-D": "MSS ausgelöst FC0093", + "TEXT-E": "MPCB triggered FC0093", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 255200.4, + 426860.3 + ] + }, + "FC0092@3": { + "IO": "FC0092", + "ID": "", + "VERW": "MS FC0092", + "BEZEICHNUNG": "MSS ausgelöst FC0092 (CV-M4301)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI5", + "TEXT-D": "MSS ausgelöst FC0092", + "TEXT-E": "MPCB triggered FC0092", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 255208.1, + 427138.7 + ] + }, + "FC0146@1": { + "IO": "FC0146", + "ID": "", + "VERW": "MS FC0146", + "BEZEICHNUNG": "MSS ausgelöst FC0146 (CV-M4103)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0146", + "TEXT-E": "MPCB triggered FC0146", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329374.5, + 451880.1 + ] + }, + "FC0150@1": { + "IO": "FC0150", + "ID": "", + "VERW": "MS FC0150", + "BEZEICHNUNG": "MSS ausgelöst FC0150 (CV-M4302)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0150", + "TEXT-E": "MPCB triggered FC0150", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 331328.7, + 453508.3 + ] + }, + "FC0141@1": { + "IO": "FC0141", + "ID": "", + "VERW": "MS FC0141", + "BEZEICHNUNG": "MSS ausgelöst FC0141 (CV-M4503)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0141", + "TEXT-E": "MPCB triggered FC0141", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329374.5, + 453230.1 + ] + }, + "FC0144@1": { + "IO": "FC0144", + "ID": "", + "VERW": "MS FC0144", + "BEZEICHNUNG": "MSS ausgelöst FC0144 (CV-M4501)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0144", + "TEXT-E": "MPCB triggered FC0144", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329370.7, + 452418.5 + ] + }, + "FC0153@1": { + "IO": "FC0153", + "ID": "", + "VERW": "MS FC0153", + "BEZEICHNUNG": "MSS ausgelöst FC0153 (Reserve)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0153 (Reserve)", + "TEXT-E": "MPCB triggered FC0153 (Reserve)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 331346.9, + 452690.1 + ] + }, + "FC0140@1": { + "IO": "FC0140", + "ID": "", + "VERW": "MSS FC0140", + "BEZEICHNUNG": "MSS ausgelöst FC0140 (KR-M4204)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0140", + "TEXT-E": "MPCB triggered FC0140", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329374.5, + 453500.1 + ] + }, + "FC0151@1": { + "IO": "FC0151", + "ID": "", + "VERW": "MS FC0151", + "BEZEICHNUNG": "MSS ausgelöst FC0151 (CV-M4402)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0151", + "TEXT-E": "MPCB triggered FC0151", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 331346.9, + 453230.1 + ] + }, + "FC0147@1": { + "IO": "FC0147", + "ID": "", + "VERW": "MS FC0147", + "BEZEICHNUNG": "MSS ausgelöst FC0147 (CV-M4203)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0147", + "TEXT-E": "MPCB triggered FC0147", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329374.5, + 451610.1 + ] + }, + "SF0120@1": { + "IO": "SF0120", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ1101", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 334976.7, + 453451.1 + ] + }, + "SF0121@1": { + "IO": "SF0121", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ1101", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 334976.7, + 453181.1 + ] + }, + "FC0143@1": { + "IO": "FC0143", + "ID": "", + "VERW": "MS FC0143", + "BEZEICHNUNG": "MSS ausgelöst FC0143 (CV-M4403)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0143", + "TEXT-E": "MPCB triggered FC0143", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329374.5, + 452690.1 + ] + }, + "FC0142@1": { + "IO": "FC0142", + "ID": "", + "VERW": "MS FC0142", + "BEZEICHNUNG": "MSS ausgelöst FC0142 (CV-M4502)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0142", + "TEXT-E": "MPCB triggered FC0142", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329374.5, + 452960.1 + ] + }, + "SF0127@1": { + "IO": "SF0127", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ1104", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 313036.3, + 450182.7 + ] + }, + "DI0100@1": { + "IO": "DI0100", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Meldekontakt 400V Motor+Bremse", + "KENNZEICHNUNG": "=A01+UC011-KF1DI1", + "TEXT-D": "Meldekontakt 400V Motor+Bremse", + "TEXT-E": "Signal contact 400V motor+brake", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329462.4, + 457182.0 + ] + }, + "DI0101@1": { + "IO": "DI0101", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC101)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC101)", + "TEXT-E": "Pre-fuse 24V OK (FC101)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329462.4, + 456912.0 + ] + }, + "DI0102@1": { + "IO": "DI0102", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC102)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC102)", + "TEXT-E": "Pre-fuse 24V OK (FC102)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329462.4, + 456642.0 + ] + }, + "SF0117@1": { + "IO": "SF0117", + "ID": "9999", + "VERW": "IPB-CL-NO", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UC011-KF1DI1", + "TEXT-D": "LDT Reset", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329344.4, + 459232.9 + ] + }, + "SF0710@1": { + "IO": "SF0710", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UC011", + "KENNZEICHNUNG": "=A01+UC011-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329344.4, + 458152.9 + ] + }, + "SF0714@1": { + "IO": "SF0714", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UC011", + "KENNZEICHNUNG": "=A01+UC011-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329344.4, + 457882.9 + ] + }, + "UC0312": { + "A": "0", + "B": "UC0312", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 266800.4, + 448858.9 + ] + }, + "PF0087@3": { + "IO": "PF0087", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0312", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 275784.9, + 449289.4 + ] + }, + "PF0086@3": { + "IO": "PF0086", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0312", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 275784.9, + 449829.4 + ] + }, + "PF0131@1": { + "IO": "PF0131", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ1105", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 299823.2, + 450211.9 + ] + }, + "PF0130@1": { + "IO": "PF0130", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ1105", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 299823.2, + 450751.9 + ] + }, + "PF0127@1": { + "IO": "PF0127", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ1104", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 313778.8, + 450182.7 + ] + }, + "PF0126@1": { + "IO": "PF0126", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ1104", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 313778.8, + 450722.7 + ] + }, + "PF0125@1": { + "IO": "PF0125", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ1103", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329407.3, + 450175.2 + ] + }, + "PF0124@1": { + "IO": "PF0124", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ1103", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329407.3, + 450715.2 + ] + }, + "PF0123@1": { + "IO": "PF0123", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ1102", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 353828.1, + 454925.0 + ] + }, + "PF0122@1": { + "IO": "PF0122", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ1102", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 353828.1, + 455465.0 + ] + }, + "PF0121@1": { + "IO": "PF0121", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ1101", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 335719.2, + 453181.1 + ] + }, + "PF0120@1": { + "IO": "PF0120", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ1101", + "KENNZEICHNUNG": "=A01+UC011-KF1DI2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 335719.2, + 453721.1 + ] + }, + "PF0100@1": { + "IO": "PF0100", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IL compressed air foult", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330086.9, + 458962.9 + ] + }, + "PF0101@1": { + "IO": "PF0101", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "IL Trouble motor protection swtich", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330086.9, + 458692.9 + ] + }, + "PF0102@1": { + "IO": "PF0102", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "IL fuse failure", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330086.9, + 458422.9 + ] + }, + "PF0117@1": { + "IO": "PF0117", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UC011-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330086.9, + 459232.9 + ] + }, + "UC1102": { + "A": "0", + "B": "UC1102", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 354612.0, + 453967.9 + ] + }, + "UC1103": { + "A": "0", + "B": "UC1103", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 327750.4, + 449172.2 + ] + }, + "UC1101": { + "A": "0", + "B": "UC1101", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 332304.8, + 167295.4 + ] + }, + "FC0090": { + "A": "0", + "B": "FC0090", + "C": "20090710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 255200.4, + 427817.9 + ] + }, + "FC0091": { + "A": "0", + "B": "FC0091", + "C": "20091710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 255200.4, + 427547.9 + ] + }, + "FC0093": { + "A": "0", + "B": "FC0093", + "C": "20093710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 255200.4, + 427007.9 + ] + }, + "FC0092": { + "A": "0", + "B": "FC0092", + "C": "20092710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 255200.4, + 427277.9 + ] + }, + "FC0146": { + "A": "0", + "B": "FC0146", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 254787.5, + 306292.3 + ] + }, + "FC0150": { + "A": "0", + "B": "FC0150", + "C": "20150710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331347.2, + 453646.6 + ] + }, + "FC0141": { + "A": "0", + "B": "FC0141", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252874.4, + 306562.3 + ] + }, + "FC0144": { + "A": "0", + "B": "FC0144", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 254787.5, + 306832.3 + ] + }, + "FC0153": { + "A": "0", + "B": "FC0153", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331347.2, + 452836.6 + ] + }, + "FC0140": { + "A": "0", + "B": "FC0140", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252874.4, + 306832.3 + ] + }, + "FC0151": { + "A": "0", + "B": "FC0151", + "C": "20151710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331347.2, + 453376.6 + ] + }, + "FC0147": { + "A": "0", + "B": "FC0147", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329374.8, + 451756.6 + ] + }, + "FC0143": { + "A": "0", + "B": "FC0143", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252874.4, + 306022.3 + ] + }, + "FC0142": { + "A": "0", + "B": "FC0142", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252874.4, + 306292.3 + ] + }, + "DI0110@1": { + "IO": "DI0110", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"No fire alarm\"", + "KENNZEICHNUNG": "=A01+UC011-KF1DI1", + "TEXT-D": "IF BST \"No fire alarm\"", + "TEXT-E": "IF BST \"No fire alarm\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 360742.3, + 457084.7 + ] + }, + "DI0111@1": { + "IO": "DI0111", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"Non fault\"", + "KENNZEICHNUNG": "=A01+UC011-KF1DI1", + "TEXT-D": "IF BST \"Non fault\"", + "TEXT-E": "IF BST \"Non fault\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 360742.3, + 456814.7 + ] + }, + "DI0112@1": { + "IO": "DI0112", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"FPC opened\"", + "KENNZEICHNUNG": "=A01+UC011-KF1DI1", + "TEXT-D": "IF BST \"FPC opened\"", + "TEXT-E": "IF BST \"FPC opened\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 360742.3, + 456544.7 + ] + }, + "SF0080@3": { + "IO": "SF0080", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Betriebshalt UZ0309", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Betriebshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 245225.9, + 445839.8 + ] + }, + "SF0081@3": { + "IO": "SF0081", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0309", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 245225.9, + 445569.8 + ] + }, + "SF0084@3": { + "IO": "SF0084", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0311", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253860.3, + 450759.7 + ] + }, + "SF0085@3": { + "IO": "SF0085", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0311", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253860.3, + 450489.7 + ] + }, + "SF0471@3": { + "IO": "SF0471", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0309", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 245225.9, + 445269.6 + ] + }, + "SF0475@3": { + "IO": "SF0475", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0309", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 245225.9, + 444999.6 + ] + }, + "FC0074@3": { + "IO": "FC0074", + "ID": "", + "VERW": "MS FC0074", + "BEZEICHNUNG": "MSS ausgelöst FC0074 (CV-M4101)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI9", + "TEXT-D": "MSS ausgelöst FC0074", + "TEXT-E": "MPCB triggered FC0074", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 255201.7, + 428251.6 + ] + }, + "FC0075@3": { + "IO": "FC0075", + "ID": "", + "VERW": "MS FC0075", + "BEZEICHNUNG": "MSS ausgelöst FC0075 (CV-M4201)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI9", + "TEXT-D": "MSS ausgelöst FC0075", + "TEXT-E": "MPCB triggered FC0075", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 255200.1, + 427980.1 + ] + }, + "FC0140@3": { + "IO": "FC0140", + "ID": "", + "VERW": "MSS FC0140", + "BEZEICHNUNG": "MSS ausgelöst FC0140 (KR-M2101)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI03", + "TEXT-D": "MSS ausgelöst FC0140", + "TEXT-E": "MPCB triggered FC0140", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252810.4, + 456484.7 + ] + }, + "FC0141@3": { + "IO": "FC0141", + "ID": "", + "VERW": "MS FC0141", + "BEZEICHNUNG": "MSS ausgelöst FC0141 (KR-M2102)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI03", + "TEXT-D": "MSS ausgelöst FC0141", + "TEXT-E": "MPCB triggered FC0141", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252810.4, + 456214.7 + ] + }, + "FC0062@3": { + "IO": "FC0062", + "ID": "", + "VERW": "MS FC0062", + "BEZEICHNUNG": "MSS ausgelöst FC0062 (KR-M2201)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0062", + "TEXT-E": "MPCB triggered FC0062", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252775.2, + 428790.1 + ] + }, + "FC0061@3": { + "IO": "FC0061", + "ID": "", + "VERW": "MS FC0061", + "BEZEICHNUNG": "MSS ausgelöst FC0061 (KR-M2104)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0061", + "TEXT-E": "MPCB triggered FC0061", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252775.2, + 429060.1 + ] + }, + "SF0120@3": { + "IO": "SF0120", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3101", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181453.1, + 460377.0 + ] + }, + "SF0711@3": { + "IO": "SF0711", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3101", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181453.1, + 459816.6 + ] + }, + "SF0715@3": { + "IO": "SF0715", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3101", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181453.1, + 459546.6 + ] + }, + "SF0121@3": { + "IO": "SF0121", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3101", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181453.1, + 460107.0 + ] + }, + "SF0122@3": { + "IO": "SF0122", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3102", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200226.3, + 460430.9 + ] + }, + "SF0123@3": { + "IO": "SF0123", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3102", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200226.3, + 460160.9 + ] + }, + "SF0780@3": { + "IO": "SF0780", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3104", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI2", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 234665.5, + 459821.2 + ] + }, + "SF0784@3": { + "IO": "SF0784", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3104", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI2", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 234665.5, + 459551.2 + ] + }, + "SF0402@3": { + "IO": "SF0402", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0302", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI6", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 195117.7, + 440222.5 + ] + }, + "SF0406@3": { + "IO": "SF0406", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0302", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI6", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 195117.7, + 439952.5 + ] + }, + "SF0470@3": { + "IO": "SF0470", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0304", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI7", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 230317.3, + 440127.1 + ] + }, + "SF0474@3": { + "IO": "SF0474", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0304", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI7", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 230317.3, + 439857.1 + ] + }, + "FC0142@3": { + "IO": "FC0142", + "ID": "", + "VERW": "MS FC0142", + "BEZEICHNUNG": "MSS ausgelöst FC0142 (CV-M2105)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI03", + "TEXT-D": "MSS ausgelöst FC0142", + "TEXT-E": "MPCB triggered FC0142", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252811.4, + 455942.5 + ] + }, + "FC0143@3": { + "IO": "FC0143", + "ID": "", + "VERW": "MS FC0143", + "BEZEICHNUNG": "MSS ausgelöst FC0143 (CV-M2106)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI03", + "TEXT-D": "MSS ausgelöst FC0143", + "TEXT-E": "MPCB triggered FC0143", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 254920.8, + 456484.7 + ] + }, + "FC0144@3": { + "IO": "FC0144", + "ID": "", + "VERW": "MS FC0144", + "BEZEICHNUNG": "MSS ausgelöst FC0144 (CV-M2107)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI03", + "TEXT-D": "MSS ausgelöst FC0144", + "TEXT-E": "MPCB triggered FC0144", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 254920.8, + 456204.7 + ] + }, + "FC0145@3": { + "IO": "FC0145", + "ID": "", + "VERW": "MS FC0145", + "BEZEICHNUNG": "MSS ausgelöst FC0145 (CV-M2108)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI03", + "TEXT-D": "MSS ausgelöst FC0145", + "TEXT-E": "MPCB triggered FC0145", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 254920.8, + 455944.7 + ] + }, + "FC0063@3": { + "IO": "FC0063", + "ID": "", + "VERW": "MS FC0063", + "BEZEICHNUNG": "MSS ausgelöst FC0063 (KR-M2202)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0063", + "TEXT-E": "MPCB triggered FC0063", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252775.2, + 428520.1 + ] + }, + "FC0200@3": { + "IO": "FC0200", + "ID": "", + "VERW": "MS FC0200", + "BEZEICHNUNG": "MSS ausgelöst FC0200 (KR-M2203)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0200", + "TEXT-E": "MPCB triggered FC0200", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252692.4, + 415790.7 + ] + }, + "FC0201@3": { + "IO": "FC0201", + "ID": "", + "VERW": "MS FC0201", + "BEZEICHNUNG": "MSS ausgelöst FC0201 (KR-M0201)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0201", + "TEXT-E": "MPCB triggered FC0201", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252691.8, + 415520.7 + ] + }, + "FC0064@3": { + "IO": "FC0064", + "ID": "", + "VERW": "MS FC0064", + "BEZEICHNUNG": "MSS ausgelöst FC0064 (CV-M2205)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0064", + "TEXT-E": "MPCB triggered FC0064", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252775.2, + 428250.1 + ] + }, + "FC0065@3": { + "IO": "FC0065", + "ID": "", + "VERW": "MS FC0065", + "BEZEICHNUNG": "MSS ausgelöst FC0065 (CV-M2206)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0065", + "TEXT-E": "MPCB triggered FC0065", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252775.2, + 427980.1 + ] + }, + "FC0066@3": { + "IO": "FC0066", + "ID": "", + "VERW": "MS FC0066", + "BEZEICHNUNG": "MSS ausgelöst FC0066 (CV-M2207)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0066", + "TEXT-E": "MPCB triggered FC0066", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252775.2, + 427710.1 + ] + }, + "FC0067@3": { + "IO": "FC0067", + "ID": "", + "VERW": "MS FC0067", + "BEZEICHNUNG": "MSS ausgelöst FC0067 (CV-M2208)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0067", + "TEXT-E": "MPCB triggered FC0067", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252775.2, + 427440.1 + ] + }, + "FC0202@3": { + "IO": "FC0202", + "ID": "", + "VERW": "MS FC0202", + "BEZEICHNUNG": "MSS ausgelöst FC0202 (KR-M2301)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0202", + "TEXT-E": "MPCB triggered FC0202", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252691.8, + 415250.7 + ] + }, + "FC0203@3": { + "IO": "FC0203", + "ID": "", + "VERW": "MS FC0203", + "BEZEICHNUNG": "MSS ausgelöst FC0203 (KR-M2302)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0203", + "TEXT-E": "MPCB triggered FC0203", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252691.8, + 414980.7 + ] + }, + "SF0712@3": { + "IO": "SF0712", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3102", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200226.3, + 459870.9 + ] + }, + "SF0716@3": { + "IO": "SF0716", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3102", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200226.3, + 459600.9 + ] + }, + "SF0401@3": { + "IO": "SF0401", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0301", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI6", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 180258.1, + 440131.1 + ] + }, + "SF0405@3": { + "IO": "SF0405", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0301", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI6", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 180258.1, + 439861.1 + ] + }, + "SF0403@3": { + "IO": "SF0403", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0303", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI6", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212646.2, + 440226.3 + ] + }, + "SF0407@3": { + "IO": "SF0407", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0303", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI6", + "TEXT-D": "E-stop Kanal 2", + "TEXT-E": "E-Stop canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212646.2, + 439956.3 + ] + }, + "SF1021@3": { + "IO": "SF1021", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3201", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181394.5, + 420505.5 + ] + }, + "SF1025@3": { + "IO": "SF1025", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3201", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181394.5, + 420235.5 + ] + }, + "SF1022@3": { + "IO": "SF1022", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3202", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 199578.6, + 420531.5 + ] + }, + "SF1026@3": { + "IO": "SF1026", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3202", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 199578.6, + 420261.5 + ] + }, + "SF1023@3": { + "IO": "SF1023", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3203", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 211891.9, + 420756.7 + ] + }, + "SF1027@3": { + "IO": "SF1027", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3203", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 211891.9, + 420486.7 + ] + }, + "SF1090@3": { + "IO": "SF1090", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3204", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 230042.3, + 420273.2 + ] + }, + "SF1094@3": { + "IO": "SF1094", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3204", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 230042.3, + 420003.2 + ] + }, + "SF1331@3": { + "IO": "SF1331", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3301", + "KENNZEICHNUNG": "=A01+UC033-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181407.1, + 397087.2 + ] + }, + "SF1335@3": { + "IO": "SF1335", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3301", + "KENNZEICHNUNG": "=A01+UC033-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181407.1, + 396817.2 + ] + }, + "SF1332@3": { + "IO": "SF1332", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3302", + "KENNZEICHNUNG": "=A01+UC033-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200233.2, + 397165.2 + ] + }, + "SF1336@3": { + "IO": "SF1336", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3302", + "KENNZEICHNUNG": "=A01+UC033-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200233.2, + 396895.2 + ] + }, + "SF1400@3": { + "IO": "SF1400", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3304", + "KENNZEICHNUNG": "=A01+UC033-KF1DI2", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235073.6, + 397065.2 + ] + }, + "SF1404@3": { + "IO": "SF1404", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3304", + "KENNZEICHNUNG": "=A01+UC033-KF1DI2", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235073.6, + 396795.2 + ] + }, + "SF0046@3": { + "IO": "SF0046", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0304", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 230317.3, + 440687.1 + ] + }, + "SF0047@3": { + "IO": "SF0047", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0304", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 230317.3, + 440417.1 + ] + }, + "SF0056@3": { + "IO": "SF0056", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0308", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 234637.1, + 438966.0 + ] + }, + "SF0057@3": { + "IO": "SF0057", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0308", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 234637.1, + 438696.0 + ] + }, + "SF0054@3": { + "IO": "SF0054", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0307", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 217447.0, + 439434.8 + ] + }, + "SF0055@3": { + "IO": "SF0055", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0307", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 217447.0, + 439164.8 + ] + }, + "SF0045@3": { + "IO": "SF0045", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0303", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212642.4, + 440534.7 + ] + }, + "SF0044@3": { + "IO": "SF0044", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0303", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212642.4, + 440804.7 + ] + }, + "SF0052@3": { + "IO": "SF0052", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0306", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 199696.5, + 439456.9 + ] + }, + "SF0053@3": { + "IO": "SF0053", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0306", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 199696.5, + 439198.9 + ] + }, + "SF0042@3": { + "IO": "SF0042", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0302", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 195114.2, + 440848.3 + ] + }, + "SF0043@3": { + "IO": "SF0043", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0302", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 195117.7, + 440581.2 + ] + }, + "SF0050@3": { + "IO": "SF0050", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0305", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 183867.3, + 439514.4 + ] + }, + "SF0051@3": { + "IO": "SF0051", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0305", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 183867.3, + 439244.4 + ] + }, + "SF0040@3": { + "IO": "SF0040", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0301", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 180254.6, + 440688.2 + ] + }, + "SF0041@3": { + "IO": "SF0041", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0301", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 180258.1, + 440421.1 + ] + }, + "SF0180@3": { + "IO": "SF0180", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3201", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181391.0, + 421062.6 + ] + }, + "SF0181@3": { + "IO": "SF0181", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3201", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181394.5, + 420795.5 + ] + }, + "SF0190@3": { + "IO": "SF0190", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3205", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181394.5, + 418943.9 + ] + }, + "SF0191@3": { + "IO": "SF0191", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3205", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181394.5, + 418673.9 + ] + }, + "SF0182@3": { + "IO": "SF0182", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3202", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 199578.6, + 421091.5 + ] + }, + "SF0183@3": { + "IO": "SF0183", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3202", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 199578.6, + 420828.9 + ] + }, + "SF0192@3": { + "IO": "SF0192", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3206", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 199578.6, + 418986.7 + ] + }, + "SF0193@3": { + "IO": "SF0193", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3206", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 199578.6, + 418716.7 + ] + }, + "SF0184@3": { + "IO": "SF0184", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3203", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 211891.9, + 421316.7 + ] + }, + "SF0185@3": { + "IO": "SF0185", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3203", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 211891.9, + 421046.7 + ] + }, + "SF0194@3": { + "IO": "SF0194", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3207", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 211891.9, + 418989.1 + ] + }, + "SF0195@3": { + "IO": "SF0195", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3207", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 211891.9, + 418708.0 + ] + }, + "SF0186@3": { + "IO": "SF0186", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3204", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 230042.3, + 420941.5 + ] + }, + "SF0187@3": { + "IO": "SF0187", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3204", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 230042.3, + 420671.5 + ] + }, + "SF0196@3": { + "IO": "SF0196", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3208", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 234637.1, + 418607.9 + ] + }, + "SF0197@3": { + "IO": "SF0197", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3208", + "KENNZEICHNUNG": "=A01+UC032-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 234637.1, + 418337.9 + ] + }, + "SF0240@3": { + "IO": "SF0240", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3301", + "KENNZEICHNUNG": "=A01+UC033-KF1DI2", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181403.6, + 397644.3 + ] + }, + "SF0241@3": { + "IO": "SF0241", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3301", + "KENNZEICHNUNG": "=A01+UC033-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181407.1, + 397377.2 + ] + }, + "SF0242@3": { + "IO": "SF0242", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3302", + "KENNZEICHNUNG": "=A01+UC033-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200233.2, + 397725.2 + ] + }, + "SF0243@3": { + "IO": "SF0243", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3302", + "KENNZEICHNUNG": "=A01+UC033-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200233.2, + 397455.2 + ] + }, + "SF0246@3": { + "IO": "SF0246", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3304", + "KENNZEICHNUNG": "=A01+UC033-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235073.6, + 397625.2 + ] + }, + "SF0247@3": { + "IO": "SF0247", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3304", + "KENNZEICHNUNG": "=A01+UC033-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235073.6, + 397355.2 + ] + }, + "FC0260@3": { + "IO": "FC0260", + "ID": "", + "VERW": "MS FC0260", + "BEZEICHNUNG": "MSS ausgelöst FC0260 (KR-M2303)", + "KENNZEICHNUNG": "=A01+UC033-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0260", + "TEXT-E": "MPCB triggered FC0260", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252692.4, + 398454.8 + ] + }, + "FC0263@3": { + "IO": "FC0263", + "ID": "", + "VERW": "MS FC0263", + "BEZEICHNUNG": "MSS ausgelöst FC0263 (CV-M2306)", + "KENNZEICHNUNG": "=A01+UC033-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0263", + "TEXT-E": "MPCB triggered FC0263", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252692.4, + 397644.8 + ] + }, + "FC0261@3": { + "IO": "FC0261", + "ID": "", + "VERW": "MS FC0261", + "BEZEICHNUNG": "MSS ausgelöst FC0261 (KR-M2304)", + "KENNZEICHNUNG": "=A01+UC033-KF1DI3", + "TEXT-D": "", + "TEXT-E": "MPCB triggered FC0261", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252692.4, + 398184.8 + ] + }, + "FC0264@3": { + "IO": "FC0264", + "ID": "", + "VERW": "MS FC0264", + "BEZEICHNUNG": "MSS ausgelöst FC0264 (CV-M2307)", + "KENNZEICHNUNG": "=A01+UC033-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0264", + "TEXT-E": "MPCB triggered FC0264", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252692.4, + 397374.8 + ] + }, + "SF0244@3": { + "IO": "SF0244", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3303", + "KENNZEICHNUNG": "=A01+UC033-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212835.4, + 397421.5 + ] + }, + "SF0245@3": { + "IO": "SF0245", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3303", + "KENNZEICHNUNG": "=A01+UC033-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212835.4, + 397151.5 + ] + }, + "SF1333@3": { + "IO": "SF1333", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3303", + "KENNZEICHNUNG": "=A01+UC033-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212835.4, + 396827.7 + ] + }, + "SF1337@3": { + "IO": "SF1337", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3303", + "KENNZEICHNUNG": "=A01+UC033-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212835.4, + 396557.7 + ] + }, + "FC0265@3": { + "IO": "FC0265", + "ID": "", + "VERW": "MS FC0265", + "BEZEICHNUNG": "MSS ausgelöst FC0265 (CV-M2308)", + "KENNZEICHNUNG": "=A01+UC033-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0265", + "TEXT-E": "MPCB triggered FC0265", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252692.4, + 397104.8 + ] + }, + "SF0126@3": { + "IO": "SF0126", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3104", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 234665.5, + 460391.4 + ] + }, + "SF0127@3": { + "IO": "SF0127", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3104", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 234665.5, + 460121.4 + ] + }, + "SF0124@3": { + "IO": "SF0124", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ3103", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 211815.3, + 460471.2 + ] + }, + "SF0125@3": { + "IO": "SF0125", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ3103", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 211815.3, + 460201.2 + ] + }, + "SF0713@3": { + "IO": "SF0713", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ3103", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 211815.3, + 459911.2 + ] + }, + "SF0717@3": { + "IO": "SF0717", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ3103", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 211815.3, + 459641.2 + ] + }, + "FC0070@3": { + "IO": "FC0070", + "ID": "", + "VERW": "MS FC0070", + "BEZEICHNUNG": "MSS ausgelöst FC0070 (CV-M2109)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI9", + "TEXT-D": "MSS ausgelöst FC0070", + "TEXT-E": "MPCB triggered FC0070", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 255200.1, + 429330.1 + ] + }, + "SF0000@3": { + "IO": "SF0000", + "ID": "9999", + "VERW": "PB-BK-NC", + "BEZEICHNUNG": "DT Anlage Aus ", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "DT Anlage Aus", + "TEXT-E": "PB System Off", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 442428.2 + ] + }, + "SF0001@3": { + "IO": "SF0001", + "ID": "9999", + "VERW": "IPB-GN-NO", + "BEZEICHNUNG": "LDT Anlage Ein", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "LDT Anlage Ein", + "TEXT-E": "IPB system On", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 442158.2 + ] + }, + "SF0002@3": { + "IO": "SF0002", + "ID": "9999", + "VERW": "IPB-CL-NO", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "LDT Start nach Störung", + "TEXT-E": "IPB Start after Trouble", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 441888.2 + ] + }, + "SF0003@3": { + "IO": "SF0003", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "LM Lampentest", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "LM Lampentest", + "TEXT-E": "IL Lamp test", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 441618.2 + ] + }, + "DI0005@3": { + "IO": "DI0005", + "ID": "9999", + "VERW": "RELAY-NO", + "BEZEICHNUNG": "Phasenausfall 400V", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "Phasenausfall 400V", + "TEXT-E": "Phase failure relay 400V", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 438873.1 + ] + }, + "DI0006@3": { + "IO": "DI0006", + "ID": "9999", + "VERW": "400V-OK ", + "BEZEICHNUNG": "Vorsicherung 400V UC031", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "Vorsicherung 400V UC031", + "TEXT-E": "Pre-fuse 400V UC031", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 438603.1 + ] + }, + "DI0007@3": { + "IO": "DI0007", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC032", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "Vorsicherung 400V UC032", + "TEXT-E": "Pre-fuse 400V UC032", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 438333.1 + ] + }, + "DI0010@3": { + "IO": "DI0010", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC033", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "Vorsicherung 400V UC033", + "TEXT-E": "Pre-fuse 400V UC033", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 438063.1 + ] + }, + "DI0011@3": { + "IO": "DI0011", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC Reserve", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "Vorsicherung 400V Reserve", + "TEXT-E": "Pre-fuse 400V Reserve", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 437793.1 + ] + }, + "DI0012@3": { + "IO": "DI0012", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC Reserve", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "Vorsicherung 400V Reserve", + "TEXT-E": "Pre-fuse 400V Reserve", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 437523.1 + ] + }, + "DI0021@3": { + "IO": "DI0021", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC021)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC021)", + "TEXT-E": "Pre-fuse 24V OK (FC021)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 436863.1 + ] + }, + "DI0022@3": { + "IO": "DI0022", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC022)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC022)", + "TEXT-E": "Pre-fuse 24V OK (FC022)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 436593.1 + ] + }, + "DI0023@3": { + "IO": "DI0023", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC023)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC023)", + "TEXT-E": "Pre-fuse 24V OK (FC023)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 436323.1 + ] + }, + "DI0024@3": { + "IO": "DI0024", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC024)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC024)", + "TEXT-E": "Pre-fuse 24V OK (FC024)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 436053.1 + ] + }, + "DI0026@3": { + "IO": "DI0026", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC026)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC026)", + "TEXT-E": "Pre-fuse 24V OK (FC026)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 435513.1 + ] + }, + "DI0100@3": { + "IO": "DI0100", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Meldekontakt 400V Motor+Bremse", + "KENNZEICHNUNG": "=A01+UC031-KF1DI1", + "TEXT-D": "Meldekontakt 400V Motor+Bremse", + "TEXT-E": "Signal contact 400V motor+brake", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252828.8, + 460611.8 + ] + }, + "DI0101@3": { + "IO": "DI0101", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC101)", + "KENNZEICHNUNG": "=A01+UC031-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC101)", + "TEXT-E": "Pre-fuse 24V OK (FC101)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252828.8, + 460341.8 + ] + }, + "DI0102@3": { + "IO": "DI0102", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC102)", + "KENNZEICHNUNG": "=A01+UC031-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC102)", + "TEXT-E": "Pre-fuse 24V OK (FC102)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252828.8, + 460071.8 + ] + }, + "DI0103@3": { + "IO": "DI0103", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC103)", + "KENNZEICHNUNG": "=A01+UC031-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC103)", + "TEXT-E": "Pre-fuse 24V OK (FC103)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252828.8, + 459801.8 + ] + }, + "DI0160@3": { + "IO": "DI0160", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Meldekontakt 400V Motor+Bremse", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "Meldekontakt 400V Motor+Bremse", + "TEXT-E": "Signal contact 400V motor+brake", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 420574.2 + ] + }, + "DI0161@3": { + "IO": "DI0161", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC161)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC161)", + "TEXT-E": "Pre fuse 24V OK (FC161)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 420304.2 + ] + }, + "DI0162@3": { + "IO": "DI0162", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC162)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC162)", + "TEXT-E": "Pre fuse 24V OK (FC162)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 420034.2 + ] + }, + "DI0163@3": { + "IO": "DI0163", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC163)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC163)", + "TEXT-E": "Pre fuse 24V OK (FC163)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 419764.2 + ] + }, + "DI0164@3": { + "IO": "DI0164", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC164)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC164)", + "TEXT-E": "Pre fuse 24V OK (FC164)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 419494.2 + ] + }, + "SF0710@3": { + "IO": "SF0710", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UC031", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252828.8, + 461692.3 + ] + }, + "SF0714@3": { + "IO": "SF0714", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UC031", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252828.8, + 461422.3 + ] + }, + "SF0400@3": { + "IO": "SF0400", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UH03", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 439998.2 + ] + }, + "SF0404@3": { + "IO": "SF0404", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UH03", + "KENNZEICHNUNG": "=A01+UH03-KF1DI3", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 439728.2 + ] + }, + "SF0117@3": { + "IO": "SF0117", + "ID": "9999", + "VERW": "IPB-CL-NO", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UC031-KF1DI1", + "TEXT-D": "LDT Reset", + "TEXT-E": "IPB Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252828.8, + 462772.3 + ] + }, + "SF1020@3": { + "IO": "SF1020", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UC032", + "KENNZEICHNUNG": "=A01+UC032-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 421902.3 + ] + }, + "SF1024@3": { + "IO": "SF1024", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UC032", + "KENNZEICHNUNG": "=A01+UC032-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 421632.3 + ] + }, + "SF0177@3": { + "IO": "SF0177", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "LDT Reset", + "TEXT-E": "IPB Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 423004.2 + ] + }, + "DI0220@3": { + "IO": "DI0220", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Meldekontakt 400V Motor+Bremse", + "KENNZEICHNUNG": "=A01+UC033-KF1DI1", + "TEXT-D": "Meldekontakt 400V Motor+Bremse", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 402382.5 + ] + }, + "DI0221@3": { + "IO": "DI0221", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC221)", + "KENNZEICHNUNG": "=A01+UC033-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC221)", + "TEXT-E": "Pre fuse 24V OK (FC221)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 402112.5 + ] + }, + "DI0222@3": { + "IO": "DI0222", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC222)", + "KENNZEICHNUNG": "=A01+UC033-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC222)", + "TEXT-E": "Pre fuse 24V OK (FC222)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 401842.5 + ] + }, + "DI0223@3": { + "IO": "DI0223", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC223)", + "KENNZEICHNUNG": "=A01+UC033-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC223)", + "TEXT-E": "Pre fuse 24V OK (FC223)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 401572.5 + ] + }, + "DI0226@3": { + "IO": "DI0226", + "ID": "9999", + "VERW": "NC", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv (QA1540/QA1541)", + "KENNZEICHNUNG": "=A01+UC033-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv (QA1540/QA1541)", + "TEXT-E": "Feedback 400V Main relay activ (QA1540/QA1541)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 400976.3 + ] + }, + "SF1330@3": { + "IO": "SF1330", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UC033", + "KENNZEICHNUNG": "=A01+UC033-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 403570.7 + ] + }, + "SF1334@3": { + "IO": "SF1334", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UC033", + "KENNZEICHNUNG": "=A01+UC033-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 403300.7 + ] + }, + "SF0237@3": { + "IO": "SF0237", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UC033-KF1DI1", + "TEXT-D": "LDT Reset", + "TEXT-E": "IPB Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 404672.6 + ] + }, + "DI0016@3": { + "IO": "DI0016", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Sicherungsautomatenfall", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "Sicherungsautomatenfall", + "TEXT-E": "Circuit breaker case", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 437194.5 + ] + }, + "DI0025@3": { + "IO": "DI0025", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC025)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC025)", + "TEXT-E": "Pre-fuse 24V OK (FC025)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 435783.1 + ] + }, + "DI0234@3": { + "IO": "DI0234", + "ID": "9999", + "VERW": "NC", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA1542/QA1543)", + "KENNZEICHNUNG": "=A01+UC033-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA1542/QA1543)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA1542/QA1543)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 400101.0 + ] + }, + "DI0165@3": { + "IO": "DI0165", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC165)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC165)", + "TEXT-E": "Pre fuse 24V OK (FC165)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 419224.2 + ] + }, + "FC0204@3": { + "IO": "FC0204", + "ID": "", + "VERW": "MS FC0204", + "BEZEICHNUNG": "MSS ausgelöst FC0204 (CV-M2309)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0204", + "TEXT-E": "MPCB triggered FC0204", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252691.8, + 414710.7 + ] + }, + "FC0205@3": { + "IO": "FC0205", + "ID": "", + "VERW": "MS FC0205", + "BEZEICHNUNG": "MSS ausgelöst FC0205 (CV-M2209)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0205", + "TEXT-E": "MPCB triggered FC0205", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252691.8, + 414440.7 + ] + }, + "SF0082@3": { + "IO": "SF0082", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0310", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 245462.7, + 432894.4 + ] + }, + "SF0083@3": { + "IO": "SF0083", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0310", + "KENNZEICHNUNG": "=A01+UC031-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 245462.7, + 432624.4 + ] + }, + "SF0472@3": { + "IO": "SF0472", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0310", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 245466.9, + 432324.2 + ] + }, + "SF0476@3": { + "IO": "SF0476", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0310", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 245466.9, + 432054.2 + ] + }, + "FC0071@3": { + "IO": "FC0071", + "ID": "", + "VERW": "MS FC0071", + "BEZEICHNUNG": "MSS ausgelöst FC0071 (KR-M2110)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI9", + "TEXT-D": "MSS ausgelöst FC0071", + "TEXT-E": "MPCB triggered FC0071", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 255200.1, + 429060.1 + ] + }, + "FC0073@3": { + "IO": "FC0073", + "ID": "", + "VERW": "MS FC0073", + "BEZEICHNUNG": "MSS ausgelöst FC0073 (CV-M2111)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI9", + "TEXT-D": "MSS ausgelöst FC0073", + "TEXT-E": "MPCB triggered FC0073", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 255200.1, + 428520.1 + ] + }, + "FC0072@3": { + "IO": "FC0072", + "ID": "", + "VERW": "MS FC0072", + "BEZEICHNUNG": "MSS ausgelöst FC0072 (KR-M2112)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI9", + "TEXT-D": "MSS ausgelöst FC0072", + "TEXT-E": "MPCB triggered FC0072", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 255200.1, + 428790.1 + ] + }, + "FC0060@3": { + "IO": "FC0060", + "ID": "", + "VERW": "MS FC0060", + "BEZEICHNUNG": "MSS ausgelöst FC0060 (KR-M2103)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0060", + "TEXT-E": "MPCB triggered FC0060", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252775.2, + 429330.1 + ] + }, + "DI0035@3": { + "IO": "DI0035", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"No fire alarm\"", + "KENNZEICHNUNG": "=A01+UH03-KF1DI2", + "TEXT-D": "IF BST \"No fire alarm\"", + "TEXT-E": "IF BST \"No fire alarm\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 435185.0 + ] + }, + "DI0036@3": { + "IO": "DI0036", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"Non fault\"", + "KENNZEICHNUNG": "=A01+UH03-KF1DI2", + "TEXT-D": "IF BST \"Non fault\"", + "TEXT-E": "IF BST \"Non fault\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 434915.0 + ] + }, + "DI0037@3": { + "IO": "DI0037", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"FPC opened\"", + "KENNZEICHNUNG": "=A01+UH03-KF1DI2", + "TEXT-D": "IF BST \"FPC opened\"", + "TEXT-E": "IF BST \"FPC opened\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.6, + 434645.0 + ] + }, + "UC0309": { + "A": "0", + "B": "UC0309", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244411.6, + 452249.4 + ] + }, + "UC0311": { + "A": "0", + "B": "UC0311", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250495.3, + 444031.8 + ] + }, + "UC3202": { + "A": "0", + "B": "UC3202", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197464.9, + 420972.9 + ] + }, + "UC3203": { + "A": "0", + "B": "UC3203", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215388.6, + 420968.4 + ] + }, + "UC3204": { + "A": "0", + "B": "UC3204", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232669.7, + 420985.0 + ] + }, + "UC3206": { + "A": "0", + "B": "UC3206", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197462.1, + 418849.5 + ] + }, + "UC3208": { + "A": "0", + "B": "UC3208", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232669.7, + 418849.5 + ] + }, + "UC3207": { + "A": "0", + "B": "UC3207", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 217178.0, + 418849.5 + ] + }, + "UC3201": { + "A": "0", + "B": "UC3201", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178162.5, + 420974.4 + ] + }, + "UC3205": { + "A": "0", + "B": "UC3205", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178164.5, + 418852.5 + ] + }, + "UC0310": { + "A": "0", + "B": "UC0310", + "C": "86623213910015374844", + "ARTINR": "829534306", + "BESCHR": "Camera DM280 m. Halter (ILS) - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244411.6, + 434680.3 + ] + }, + "PF0081@3": { + "IO": "PF0081", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0309", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 245968.4, + 445569.8 + ] + }, + "PF0080@3": { + "IO": "PF0080", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0309", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 245968.4, + 446109.8 + ] + }, + "PF0085@3": { + "IO": "PF0085", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0311", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 254602.8, + 450489.7 + ] + }, + "PF0084@3": { + "IO": "PF0084", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0311", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "Ready for use", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 254602.8, + 451029.7 + ] + }, + "FC0074": { + "A": "0", + "B": "FC0074", + "C": "10074710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 363728.2, + 724583.0 + ] + }, + "FC0062": { + "A": "0", + "B": "FC0062", + "C": "10091710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 361252.8, + 725123.0 + ] + }, + "FC0061": { + "A": "0", + "B": "FC0061", + "C": "10063710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 361252.8, + 725393.0 + ] + }, + "PF0121@3": { + "IO": "PF0121", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3101", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 182195.6, + 460106.6 + ] + }, + "PF0120@3": { + "IO": "PF0120", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3101", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 182195.6, + 460646.6 + ] + }, + "PF0123@3": { + "IO": "PF0123", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3102", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200968.8, + 460160.9 + ] + }, + "PF0122@3": { + "IO": "PF0122", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3102", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200968.8, + 460700.9 + ] + }, + "FC0145": { + "A": "0", + "B": "FC0145", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329374.8, + 452296.6 + ] + }, + "FC0063": { + "A": "0", + "B": "FC0063", + "C": "10073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 361252.8, + 724853.0 + ] + }, + "FC0200": { + "A": "0", + "B": "FC0200", + "C": "20203710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252669.8, + 262893.9 + ] + }, + "FC0201": { + "A": "0", + "B": "FC0201", + "C": "20203710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252669.8, + 262083.9 + ] + }, + "FC0064": { + "A": "0", + "B": "FC0064", + "C": "10073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 361252.8, + 724583.0 + ] + }, + "FC0065": { + "A": "0", + "B": "FC0065", + "C": "10073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 361252.8, + 724313.0 + ] + }, + "FC0066": { + "A": "0", + "B": "FC0066", + "C": "10073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 361252.8, + 724043.0 + ] + }, + "FC0067": { + "A": "0", + "B": "FC0067", + "C": "10067710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 213544.8, + 135869.9 + ] + }, + "FC0202": { + "A": "0", + "B": "FC0202", + "C": "20203710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252669.8, + 262353.9 + ] + }, + "PF0047@3": { + "IO": "PF0047", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0304", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 231059.8, + 440418.3 + ] + }, + "PF0046@3": { + "IO": "PF0046", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0304", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 231055.0, + 440967.0 + ] + }, + "PF0057@3": { + "IO": "PF0057", + "ID": "9999", + "VERW": "IPB-GU-LED", + "BEZEICHNUNG": "Reset UZ0308", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235379.6, + 438709.6 + ] + }, + "PF0056@3": { + "IO": "PF0056", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0308", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235379.6, + 439248.4 + ] + }, + "PF0055@3": { + "IO": "PF0055", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0307", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 218189.5, + 439164.8 + ] + }, + "PF0054@3": { + "IO": "PF0054", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0307", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 218189.5, + 439704.8 + ] + }, + "PF0045@3": { + "IO": "PF0045", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0303", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 213384.9, + 440534.7 + ] + }, + "PF0044@3": { + "IO": "PF0044", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0303", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 213384.9, + 441074.7 + ] + }, + "PF0053@3": { + "IO": "PF0053", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0330", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200439.0, + 439186.9 + ] + }, + "PF0052@3": { + "IO": "PF0052", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0330", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200439.0, + 439726.9 + ] + }, + "PF0043@3": { + "IO": "PF0043", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0302", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 195860.2, + 440581.2 + ] + }, + "PF0042@3": { + "IO": "PF0042", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0302", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 195860.2, + 441121.2 + ] + }, + "PF0051@3": { + "IO": "PF0051", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0305", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 184609.8, + 439244.4 + ] + }, + "PF0050@3": { + "IO": "PF0050", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0305", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 184609.8, + 439784.4 + ] + }, + "PF0041@3": { + "IO": "PF0041", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0301", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181000.6, + 440421.1 + ] + }, + "PF0040@3": { + "IO": "PF0040", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0301", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 181000.6, + 440961.1 + ] + }, + "PF0181@3": { + "IO": "PF0181", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3201", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 182137.0, + 420795.5 + ] + }, + "PF0180@3": { + "IO": "PF0180", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3201", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 182137.0, + 421335.5 + ] + }, + "PF0191@3": { + "IO": "PF0191", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3205", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 182137.0, + 418673.9 + ] + }, + "PF0190@3": { + "IO": "PF0190", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3205", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 182137.0, + 419213.9 + ] + }, + "PF0183@3": { + "IO": "PF0183", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3202", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200321.1, + 420821.5 + ] + }, + "PF0182@3": { + "IO": "PF0182", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3202", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200321.1, + 421361.5 + ] + }, + "PF0193@3": { + "IO": "PF0193", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3206", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200321.1, + 418716.7 + ] + }, + "PF0192@3": { + "IO": "PF0192", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3206", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200321.1, + 419256.7 + ] + }, + "PF0184@3": { + "IO": "PF0184", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3203", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212634.4, + 421586.7 + ] + }, + "PF0185@3": { + "IO": "PF0185", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3203", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212634.4, + 421046.7 + ] + }, + "PF0195@3": { + "IO": "PF0195", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3207", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212634.4, + 418708.0 + ] + }, + "PF0194@3": { + "IO": "PF0194", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3207", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212634.4, + 419248.0 + ] + }, + "PF0187@3": { + "IO": "PF0187", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3204", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 230784.8, + 420672.7 + ] + }, + "PF0186@3": { + "IO": "PF0186", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3204", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 230784.8, + 421211.5 + ] + }, + "PF0197@3": { + "IO": "PF0197", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3208", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235379.6, + 418339.1 + ] + }, + "PF0196@3": { + "IO": "PF0196", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3208", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235379.6, + 418877.9 + ] + }, + "PF0240@3": { + "IO": "PF0240", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3301", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 182149.6, + 397917.2 + ] + }, + "PF0241@3": { + "IO": "PF0241", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3301", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 182149.6, + 397377.2 + ] + }, + "PF0242@3": { + "IO": "PF0242", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3302", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200975.7, + 397995.2 + ] + }, + "PF0243@3": { + "IO": "PF0243", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3302", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 200975.7, + 397455.2 + ] + }, + "PF0246@3": { + "IO": "PF0246", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3304", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235816.1, + 397896.4 + ] + }, + "PF0247@3": { + "IO": "PF0247", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3304", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235816.1, + 397355.2 + ] + }, + "FC0260": { + "A": "0", + "B": "FC0260", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252961.9, + 248595.0 + ] + }, + "FC0263": { + "A": "0", + "B": "FC0263", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252961.9, + 247781.6 + ] + }, + "FC0261": { + "A": "0", + "B": "FC0261", + "C": "20261710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252961.9, + 248325.0 + ] + }, + "FC0264": { + "A": "0", + "B": "FC0264", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252961.9, + 247511.6 + ] + }, + "PF0244@3": { + "IO": "PF0244", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3303", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 213577.9, + 397691.5 + ] + }, + "PF0245@3": { + "IO": "PF0245", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3303", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 213577.9, + 397151.5 + ] + }, + "FC0265": { + "A": "0", + "B": "FC0265", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252961.9, + 247241.6 + ] + }, + "PF0127@3": { + "IO": "PF0127", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3104", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235408.0, + 460121.4 + ] + }, + "PF0126@3": { + "IO": "PF0126", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3104", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 235408.0, + 460661.4 + ] + }, + "PF0125@3": { + "IO": "PF0125", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ3103", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212557.8, + 460201.2 + ] + }, + "PF0124@3": { + "IO": "PF0124", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ3103", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 212557.8, + 460741.2 + ] + }, + "FC0070": { + "A": "0", + "B": "FC0070", + "C": "10073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 363728.2, + 725663.0 + ] + }, + "PF0001@3": { + "IO": "PF0001", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LDT Anlage Ein", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253536.1, + 442158.2 + ] + }, + "PF0002@3": { + "IO": "PF0002", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253536.1, + 441888.2 + ] + }, + "PF0003@3": { + "IO": "PF0003", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IL compressed air missing", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253536.1, + 441078.2 + ] + }, + "PF0004@3": { + "IO": "PF0004", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "IL motor protection tripped", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253536.1, + 440808.2 + ] + }, + "PF0005@3": { + "IO": "PF0005", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "IL fuse has tripped", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253536.1, + 440538.2 + ] + }, + "PF0006@3": { + "IO": "PF0006", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Brandfall", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ1", + "TEXT-D": "LM Brandfall", + "TEXT-E": "IL Störung Brandschutztüren", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253536.1, + 440268.2 + ] + }, + "PF0100@3": { + "IO": "PF0100", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IL compressed air foult", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253571.3, + 462502.3 + ] + }, + "PF0101@3": { + "IO": "PF0101", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "IL Trouble motor protection swtich", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253571.3, + 462232.3 + ] + }, + "PF0102@3": { + "IO": "PF0102", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "IL fuse failure", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253571.3, + 461962.3 + ] + }, + "PF0160@3": { + "IO": "PF0160", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IL compressed air foult", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253453.3, + 422734.2 + ] + }, + "PF0161@3": { + "IO": "PF0161", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "IL Trouble motor protection swtich", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253453.3, + 422464.2 + ] + }, + "PF0162@3": { + "IO": "PF0162", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "IL Fuse failure", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253453.3, + 422194.2 + ] + }, + "PF0117@3": { + "IO": "PF0117", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253571.3, + 462772.3 + ] + }, + "PF0177@3": { + "IO": "PF0177", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "LDT Reset", + "KENNZEICHNUNG": "=A01+UC032-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253453.3, + 423004.2 + ] + }, + "PF0220@3": { + "IO": "PF0220", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IL compressed air foult", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253453.3, + 404402.6 + ] + }, + "PF0221@3": { + "IO": "PF0221", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "IL Trouble motor protection swtich", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253453.3, + 404132.6 + ] + }, + "PF0222@3": { + "IO": "PF0222", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "IL Fuse failure", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253453.3, + 403862.6 + ] + }, + "PF0237@3": { + "IO": "PF0237", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "LDT Reset", + "KENNZEICHNUNG": "=A01+UC033-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253453.3, + 404672.6 + ] + }, + "PF0083@3": { + "IO": "PF0083", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0310", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 246205.2, + 432624.4 + ] + }, + "PF0082@3": { + "IO": "PF0082", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0310", + "KENNZEICHNUNG": "=A01+UC031-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 246205.2, + 433164.4 + ] + }, + "FC0071": { + "A": "0", + "B": "FC0071", + "C": "10073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 363728.2, + 725393.0 + ] + }, + "FC0073": { + "A": "0", + "B": "FC0073", + "C": "10073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 363728.2, + 724853.0 + ] + }, + "FC0072": { + "A": "0", + "B": "FC0072", + "C": "10072710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 363728.2, + 725123.0 + ] + }, + "FC0060": { + "A": "0", + "B": "FC0060", + "C": "10063710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 361252.8, + 725663.0 + ] + }, + "FC0075": { + "A": "0", + "B": "FC0075", + "C": "10074710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV1011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 363728.2, + 724313.0 + ] + }, + "DI4610@3": { + "IO": "DI4610", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"No fire alarm\"", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI3", + "TEXT-D": "IF BST \"No fire alarm\"", + "TEXT-E": "IF BST \"No fire alarm\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 248625.8, + 452383.1 + ] + }, + "DI4611@3": { + "IO": "DI4611", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"Non fault\"", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI3", + "TEXT-D": "IF BST \"Non fault\"", + "TEXT-E": "IF BST \"Non fault\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 248625.8, + 452113.1 + ] + }, + "DI4612@3": { + "IO": "DI4612", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"FPC opened\"", + "KENNZEICHNUNG": "=A01+UC0311-KF1DI3", + "TEXT-D": "IF BST \"FPC opened\"", + "TEXT-E": "IF BST \"FPC opened\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 248625.8, + 451843.1 + ] + }, + "PF0031@3": { + "IO": "PF0031", + "ID": "9999", + "VERW": "LED yellow", + "BEZEICHNUNG": "Signalsäule Gelb \" Störung\"", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ2", + "TEXT-D": "Signalsäule Gelb \" Störung\"", + "TEXT-E": "Signal tower yellow\" Trouble \" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 249240.9, + 435688.7 + ] + }, + "PF0030@3": { + "IO": "PF0030", + "ID": "9999", + "VERW": "LED red", + "BEZEICHNUNG": "Signalsäule Rot \" Störung\"", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ2", + "TEXT-D": "Signalsäule Rot \" Not-Halt\"", + "TEXT-E": "Signal tower red\" E-Stop\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 249240.9, + 435418.7 + ] + }, + "PF0032@3": { + "IO": "PF0032", + "ID": "9999", + "VERW": "LED green", + "BEZEICHNUNG": "Signalsäule grün \" Betriebsbereit\"", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ2", + "TEXT-D": "Signalsäule grün \" Betriebsbereit\"", + "TEXT-E": "Signal tower green\" System ready\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 249240.9, + 435958.7 + ] + }, + "PF0033@3": { + "IO": "PF0033", + "ID": "9999", + "VERW": "Hupe", + "BEZEICHNUNG": "Signalsäule Hupe \" Anfahrwarnung\"", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ2", + "TEXT-D": "Signalsäule Hupe \" Anfahrwarnung\"", + "TEXT-E": "Signal tower horn\" Restart warning\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 249240.9, + 436228.7 + ] + }, + "FC0140@2": { + "IO": "FC0140", + "ID": "", + "VERW": "MSS FC0140", + "BEZEICHNUNG": "MSS ausgelöst FC0140 (KR-M1101)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0140", + "TEXT-E": "MPCB triggered FC0140", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252874.1, + 306685.8 + ] + }, + "FC0141@2": { + "IO": "FC0141", + "ID": "", + "VERW": "MS FC0141", + "BEZEICHNUNG": "MSS ausgelöst FC0141 (KR-M1102)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0141", + "TEXT-E": "MPCB triggered FC0141", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252874.1, + 306415.8 + ] + }, + "FC0060@2": { + "IO": "FC0060", + "ID": "", + "VERW": "MS FC0060", + "BEZEICHNUNG": "MSS ausgelöst FC0060 (KR-M1103)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI7", + "TEXT-D": "MSS ausgelöst FC0060", + "TEXT-E": "MPCB triggered FC0060", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252775.2, + 275540.0 + ] + }, + "FC0061@2": { + "IO": "FC0061", + "ID": "", + "VERW": "MS FC0061", + "BEZEICHNUNG": "MSS ausgelöst FC0061 (KR-M1104)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI7", + "TEXT-D": "MSS ausgelöst FC0061", + "TEXT-E": "MPCB triggered FC0061", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252775.2, + 275270.0 + ] + }, + "FC0071@2": { + "IO": "FC0071", + "ID": "", + "VERW": "MS FC0071", + "BEZEICHNUNG": "MSS ausgelöst FC0071 (CV-M1401)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "MSS ausgelöst FC0071", + "TEXT-E": "MPCB triggered FC0071", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 255437.7, + 275270.0 + ] + }, + "FC0146@2": { + "IO": "FC0146", + "ID": "", + "VERW": "MS FC0146", + "BEZEICHNUNG": "MSS ausgelöst FC0146 (CV-M1109)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0146", + "TEXT-E": "MPCB triggered FC0146", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 254787.2, + 306145.8 + ] + }, + "FC0075@2": { + "IO": "FC0075", + "ID": "", + "VERW": "MS FC0075", + "BEZEICHNUNG": "MSS ausgelöst FC0075 (KR-M1110)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "MSS ausgelöst FC0075", + "TEXT-E": "MPCB triggered FC0075", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 255437.7, + 274190.0 + ] + }, + "FC0076@2": { + "IO": "FC0076", + "ID": "", + "VERW": "MS FC0076", + "BEZEICHNUNG": "MSS ausgelöst FC0076 (CV-M1801)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "MSS ausgelöst FC0076", + "TEXT-E": "MPCB triggered FC0076", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 255437.7, + 273920.0 + ] + }, + "FC0074@2": { + "IO": "FC0074", + "ID": "", + "VERW": "MS FC0074", + "BEZEICHNUNG": "MSS ausgelöst FC0074 (CV-M4701)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "MSS ausgelöst FC0074", + "TEXT-E": "MPCB triggered FC0074", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 255437.7, + 274460.0 + ] + }, + "FC0072@2": { + "IO": "FC0072", + "ID": "", + "VERW": "MS FC0072", + "BEZEICHNUNG": "MSS ausgelöst FC0072 (CV-M1501)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "MSS ausgelöst FC0072", + "TEXT-E": "MPCB triggered FC0072", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 255437.7, + 275000.0 + ] + }, + "FC0073@2": { + "IO": "FC0073", + "ID": "", + "VERW": "MS FC0073", + "BEZEICHNUNG": "MSS ausgelöst FC0073 (CV-M1601)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "MSS ausgelöst FC0073", + "TEXT-E": "MPCB triggered FC0073", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 255447.1, + 274730.4 + ] + }, + "SF0120@2": { + "IO": "SF0120", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2101", + "KENNZEICHNUNG": "=A01+UC021-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181277.4, + 310462.1 + ] + }, + "SF0711@2": { + "IO": "SF0711", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2101", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181277.4, + 309901.8 + ] + }, + "SF0715@2": { + "IO": "SF0715", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2101", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181277.4, + 309631.8 + ] + }, + "SF0121@2": { + "IO": "SF0121", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2101", + "KENNZEICHNUNG": "=A01+UC021-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181277.4, + 310192.1 + ] + }, + "DI0100@2": { + "IO": "DI0100", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Meldekontakt 400V Motor+Bremse", + "KENNZEICHNUNG": "=A01+UC021-KF1DI1", + "TEXT-D": "Meldekontakt 400V Motor+Bremse", + "TEXT-E": "Signal contact 400V motor+brake", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252828.8, + 310736.3 + ] + }, + "DI0101@2": { + "IO": "DI0101", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC101)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC101)", + "TEXT-E": "Pre-fuse 24V OK (FC101)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252828.8, + 310466.3 + ] + }, + "DI0102@2": { + "IO": "DI0102", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC102)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC102)", + "TEXT-E": "Pre-fuse 24V OK (FC102)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252828.8, + 310196.3 + ] + }, + "DI0103@2": { + "IO": "DI0103", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC103)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC103)", + "TEXT-E": "Pre-fuse 24V OK (FC103)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252828.8, + 309926.3 + ] + }, + "DI0106@2": { + "IO": "DI0106", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv (QA0920/QA0921)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv (QA0920/QA0921)", + "TEXT-E": "Feedback 400V Main relay activ (QA0920/QA0921)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252828.8, + 309240.9 + ] + }, + "DI0160@2": { + "IO": "DI0160", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Meldekontakt 400V Motor+Bremse", + "KENNZEICHNUNG": "=A01+UC022-KF1DI1", + "TEXT-D": "Meldekontakt 400V Motor+Bremse", + "TEXT-E": "Signal contact 400V motor+brake", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 267389.7 + ] + }, + "DI0161@2": { + "IO": "DI0161", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC161)", + "KENNZEICHNUNG": "=A01+UC022-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC161)", + "TEXT-E": "Pre fuse 24V OK (FC161)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 267119.7 + ] + }, + "DI0162@2": { + "IO": "DI0162", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC162)", + "KENNZEICHNUNG": "=A01+UC022-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC162)", + "TEXT-E": "Pre fuse 24V OK (FC162)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 266849.7 + ] + }, + "DI0163@2": { + "IO": "DI0163", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC163)", + "KENNZEICHNUNG": "=A01+UC022-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC163)", + "TEXT-E": "Pre fuse 24V OK (FC163)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 266579.7 + ] + }, + "DI0166@2": { + "IO": "DI0166", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv (QA1230/QA1231)", + "KENNZEICHNUNG": "=A01+UC022-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv (QA1230/QA1231)", + "TEXT-E": "Feedback 400V Main relay activ (QA1232/QA1233)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 265364.7 + ] + }, + "DI0164@2": { + "IO": "DI0164", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC164)", + "KENNZEICHNUNG": "=A01+UC022-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC164)", + "TEXT-E": "Pre fuse 24V OK (FC164)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 266309.7 + ] + }, + "SF0122@2": { + "IO": "SF0122", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2102", + "KENNZEICHNUNG": "=A01+UC021-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 199419.1, + 310608.9 + ] + }, + "SF0123@2": { + "IO": "SF0123", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2102", + "KENNZEICHNUNG": "=A01+UC021-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 199419.1, + 310338.9 + ] + }, + "SF0780@2": { + "IO": "SF0780", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2104", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI2", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234665.5, + 310002.5 + ] + }, + "SF0784@2": { + "IO": "SF0784", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2104", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI2", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234665.5, + 309732.5 + ] + }, + "SF0402@2": { + "IO": "SF0402", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0202", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI6", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 195117.7, + 290222.5 + ] + }, + "SF0406@2": { + "IO": "SF0406", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0202", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI6", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 195117.7, + 289952.5 + ] + }, + "SF0470@2": { + "IO": "SF0470", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0204", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI7", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 238287.3, + 289430.9 + ] + }, + "SF0474@2": { + "IO": "SF0474", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0204", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI7", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 238287.3, + 289160.9 + ] + }, + "FC0142@2": { + "IO": "FC0142", + "ID": "", + "VERW": "MS FC0142", + "BEZEICHNUNG": "MSS ausgelöst FC0142 (CV-M1105)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0142", + "TEXT-E": "MPCB triggered FC0142", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252874.1, + 306145.8 + ] + }, + "FC0143@2": { + "IO": "FC0143", + "ID": "", + "VERW": "MS FC0143", + "BEZEICHNUNG": "MSS ausgelöst FC0143 (CV-M1106)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0143", + "TEXT-E": "MPCB triggered FC0143", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252874.1, + 305875.8 + ] + }, + "FC0144@2": { + "IO": "FC0144", + "ID": "", + "VERW": "MS FC0144", + "BEZEICHNUNG": "MSS ausgelöst FC0144 (CV-M1107)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0144", + "TEXT-E": "MPCB triggered FC0144", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 254787.2, + 306685.8 + ] + }, + "FC0145@2": { + "IO": "FC0145", + "ID": "", + "VERW": "MS FC0145", + "BEZEICHNUNG": "MSS ausgelöst FC0145 (CV-M1108)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0145", + "TEXT-E": "MPCB triggered FC0145", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 254787.2, + 306415.8 + ] + }, + "FC0200@2": { + "IO": "FC0200", + "ID": "", + "VERW": "MS FC0200", + "BEZEICHNUNG": "MSS ausgelöst FC0200 (KR-M1203)", + "KENNZEICHNUNG": "=A01+UC022-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0200", + "TEXT-E": "MPCB triggered FC0200", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252669.5, + 262747.3 + ] + }, + "FC0201@2": { + "IO": "FC0201", + "ID": "", + "VERW": "MS FC0201", + "BEZEICHNUNG": "MSS ausgelöst FC0201 (KR-M1204)", + "KENNZEICHNUNG": "=A01+UC022-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0201", + "TEXT-E": "MPCB triggered FC0201", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252669.5, + 262477.3 + ] + }, + "FC0064@2": { + "IO": "FC0064", + "ID": "", + "VERW": "MS FC0064", + "BEZEICHNUNG": "MSS ausgelöst FC0064 (CV-M1205)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI7", + "TEXT-D": "MSS ausgelöst FC0064", + "TEXT-E": "MPCB triggered FC0064", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252775.2, + 274460.0 + ] + }, + "FC0065@2": { + "IO": "FC0065", + "ID": "", + "VERW": "MS FC0065", + "BEZEICHNUNG": "MSS ausgelöst FC0065 (CV-M1206)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI7", + "TEXT-D": "MSS ausgelöst FC0065", + "TEXT-E": "MPCB triggered FC0065", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252775.2, + 274190.0 + ] + }, + "FC0066@2": { + "IO": "FC0066", + "ID": "", + "VERW": "MS FC0066", + "BEZEICHNUNG": "MSS ausgelöst FC0066 (CV-M1207)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI7", + "TEXT-D": "MSS ausgelöst FC0066", + "TEXT-E": "MPCB triggered FC0066", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252775.2, + 273920.0 + ] + }, + "FC0067@2": { + "IO": "FC0067", + "ID": "", + "VERW": "MS FC0067", + "BEZEICHNUNG": "MSS ausgelöst FC0067 (CV-M1208)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI7", + "TEXT-D": "MSS ausgelöst FC0067", + "TEXT-E": "MPCB triggered FC0067", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252775.2, + 273650.0 + ] + }, + "FC0202@2": { + "IO": "FC0202", + "ID": "", + "VERW": "MS FC0202", + "BEZEICHNUNG": "MSS ausgelöst FC0202 (KR-M1301)", + "KENNZEICHNUNG": "=A01+UC022-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0202", + "TEXT-E": "MPCB triggered FC0202", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252669.5, + 262207.3 + ] + }, + "FC0203@2": { + "IO": "FC0203", + "ID": "", + "VERW": "MS FC0203", + "BEZEICHNUNG": "MSS ausgelöst FC0203 (KR-M1302)", + "KENNZEICHNUNG": "=A01+UC022-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0203", + "TEXT-E": "MPCB triggered FC0203", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252669.5, + 261937.3 + ] + }, + "FC0070@2": { + "IO": "FC0070", + "ID": "", + "VERW": "MS FC0070", + "BEZEICHNUNG": "MSS ausgelöst FC0070 (CV-M1209)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "MSS ausgelöst FC0070", + "TEXT-E": "MPCB triggered FC0070", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 255437.7, + 275540.0 + ] + }, + "SF0080@2": { + "IO": "SF0080", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Betriebshalt UZ0209", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "Betriebshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 245550.4, + 301081.7 + ] + }, + "SF0081@2": { + "IO": "SF0081", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0209", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 245550.4, + 300811.7 + ] + }, + "SF0082@2": { + "IO": "SF0082", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0210", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 245500.3, + 283195.6 + ] + }, + "SF0083@2": { + "IO": "SF0083", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0210", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "Reset ", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 245500.3, + 282925.6 + ] + }, + "SF0084@2": { + "IO": "SF0084", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0211", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 250188.6, + 299336.1 + ] + }, + "SF0085@2": { + "IO": "SF0085", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0211", + "KENNZEICHNUNG": "=A01+UH02-KF1DI8", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 250188.6, + 299066.1 + ] + }, + "SF0712@2": { + "IO": "SF0712", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2102", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 199419.1, + 310048.9 + ] + }, + "SF0716@2": { + "IO": "SF0716", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2102", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 199419.1, + 309778.9 + ] + }, + "SF0713@2": { + "IO": "SF0713", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2103", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 217827.4, + 310994.7 + ] + }, + "SF0717@2": { + "IO": "SF0717", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2103", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 217827.4, + 310724.7 + ] + }, + "SF0710@2": { + "IO": "SF0710", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UC021", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252710.8, + 311746.8 + ] + }, + "SF0714@2": { + "IO": "SF0714", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UC021", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252710.8, + 311476.8 + ] + }, + "SF0471@2": { + "IO": "SF0471", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0209", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 245550.4, + 300511.5 + ] + }, + "SF0475@2": { + "IO": "SF0475", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0209", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 245550.4, + 300241.5 + ] + }, + "SF0472@2": { + "IO": "SF0472", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0210", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 245504.5, + 282625.4 + ] + }, + "SF0476@2": { + "IO": "SF0476", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0210", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 245504.5, + 282355.4 + ] + }, + "SF0473@2": { + "IO": "SF0473", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0211", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 250188.6, + 298765.9 + ] + }, + "SF0477@2": { + "IO": "SF0477", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0211", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 250188.6, + 298495.9 + ] + }, + "SF0401@2": { + "IO": "SF0401", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0201", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI6", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 180258.1, + 290131.1 + ] + }, + "SF0405@2": { + "IO": "SF0405", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0201", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI6", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 180258.1, + 289861.1 + ] + }, + "SF0117@2": { + "IO": "SF0117", + "ID": "9999", + "VERW": "IPB-CL-NO", + "BEZEICHNUNG": "LDT Reset", + "KENNZEICHNUNG": "=A01+UC021-KF1DI1", + "TEXT-D": "LDT Reset", + "TEXT-E": "IPB Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252710.8, + 312826.8 + ] + }, + "DI0114@2": { + "IO": "DI0114", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA0922/QA0923)", + "KENNZEICHNUNG": "=A01+UC021-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA0922/QA0923)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0922/QA0923)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252828.8, + 308360.9 + ] + }, + "SF1020@2": { + "IO": "SF1020", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UC022", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 268489.8 + ] + }, + "SF1024@2": { + "IO": "SF1024", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UC022", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI1", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 268219.8 + ] + }, + "SF0177@2": { + "IO": "SF0177", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "LDT Reset", + "KENNZEICHNUNG": "=A01+UC022-KF1DI1", + "TEXT-D": "LDT Reset", + "TEXT-E": "IPB Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 269861.7 + ] + }, + "DI0220@2": { + "IO": "DI0220", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Meldekontakt 400V Motor+Bremse", + "KENNZEICHNUNG": "=A01+UC023-KF1DI1", + "TEXT-D": "Meldekontakt 400V Motor+Bremse", + "TEXT-E": "Signal contact 400V motor+brake", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252980.0, + 252506.9 + ] + }, + "DI0221@2": { + "IO": "DI0221", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC221)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC221)", + "TEXT-E": "Pre fuse 24V OK (FC221)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252980.0, + 252236.9 + ] + }, + "DI0222@2": { + "IO": "DI0222", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC222)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC222)", + "TEXT-E": "Pre fuse 24V OK (FC222)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252980.0, + 251966.9 + ] + }, + "DI0223@2": { + "IO": "DI0223", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC223)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC223)", + "TEXT-E": "Pre fuse 24V OK (FC223)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252980.0, + 251696.9 + ] + }, + "DI0234@2": { + "IO": "DI0234", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA1542/QA1531)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA1542/QA1543)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA1542/QA1543)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252995.9, + 250166.7 + ] + }, + "SF1330@2": { + "IO": "SF1330", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UC023", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI01", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252980.0, + 253315.5 + ] + }, + "SF1334@2": { + "IO": "SF1334", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UC023", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI01", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252980.0, + 253045.5 + ] + }, + "SF0237@2": { + "IO": "SF0237", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "LDT Reset", + "KENNZEICHNUNG": "=A01+UC023-KF1DI1", + "TEXT-D": "LDT Reset", + "TEXT-E": "IPB Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252980.0, + 254417.4 + ] + }, + "SF0403@2": { + "IO": "SF0403", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0203", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI6", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 212646.2, + 290226.3 + ] + }, + "SF0407@2": { + "IO": "SF0407", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0203", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI6", + "TEXT-D": "E-stop Kanal 2", + "TEXT-E": "E-Stop canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 212646.2, + 289956.3 + ] + }, + "SF1021@2": { + "IO": "SF1021", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2201", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 180258.1, + 270551.7 + ] + }, + "SF1025@2": { + "IO": "SF1025", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2201", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 180258.1, + 270281.7 + ] + }, + "SF1022@2": { + "IO": "SF1022", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2202", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 199578.6, + 270531.5 + ] + }, + "SF1026@2": { + "IO": "SF1026", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2202", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 199578.6, + 270261.5 + ] + }, + "SF1023@2": { + "IO": "SF1023", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2203", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI1", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211891.9, + 270756.7 + ] + }, + "SF1027@2": { + "IO": "SF1027", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2203", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI1", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211891.9, + 270486.7 + ] + }, + "SF1090@2": { + "IO": "SF1090", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2204", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI2", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234628.2, + 270159.3 + ] + }, + "SF1094@2": { + "IO": "SF1094", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2204", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI2", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234628.2, + 269889.3 + ] + }, + "SF1331@2": { + "IO": "SF1331", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2301", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI01", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181407.1, + 247087.2 + ] + }, + "SF1335@2": { + "IO": "SF1335", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2301", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI01", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181407.1, + 246817.2 + ] + }, + "SF1332@2": { + "IO": "SF1332", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2302", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI01", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200236.7, + 247165.2 + ] + }, + "SF1336@2": { + "IO": "SF1336", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2302", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI01", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200236.7, + 246895.2 + ] + }, + "SF1400@2": { + "IO": "SF1400", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2304", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI02", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235073.6, + 247065.2 + ] + }, + "SF1404@2": { + "IO": "SF1404", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2304", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI02", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235073.6, + 246795.2 + ] + }, + "SF0046@2": { + "IO": "SF0046", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0204", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 238287.3, + 289990.9 + ] + }, + "SF0047@2": { + "IO": "SF0047", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0204", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 238287.3, + 289720.9 + ] + }, + "SF0056@2": { + "IO": "SF0056", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0208", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234637.1, + 288966.0 + ] + }, + "SF0057@2": { + "IO": "SF0057", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0208", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234637.1, + 288696.0 + ] + }, + "SF0054@2": { + "IO": "SF0054", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0207", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 221690.1, + 289434.8 + ] + }, + "SF0055@2": { + "IO": "SF0055", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0207", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 221690.1, + 289164.8 + ] + }, + "SF0045@2": { + "IO": "SF0045", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0203", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 212642.4, + 290534.7 + ] + }, + "SF0044@2": { + "IO": "SF0044", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0203", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 212642.4, + 290804.7 + ] + }, + "SF0052@2": { + "IO": "SF0052", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0206", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200159.8, + 289456.9 + ] + }, + "SF0053@2": { + "IO": "SF0053", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0206", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200159.8, + 289198.9 + ] + }, + "SF0042@2": { + "IO": "SF0042", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0202", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 195114.2, + 290848.3 + ] + }, + "SF0043@2": { + "IO": "SF0043", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0202", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 195117.7, + 290581.2 + ] + }, + "SF0050@2": { + "IO": "SF0050", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0205", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 183867.3, + 289514.4 + ] + }, + "SF0051@2": { + "IO": "SF0051", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0205", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 183867.3, + 289244.4 + ] + }, + "SF0040@2": { + "IO": "SF0040", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0201", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 180254.6, + 290688.2 + ] + }, + "SF0041@2": { + "IO": "SF0041", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0201", + "KENNZEICHNUNG": "=A01+UH02-KF1DI3", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 180258.1, + 290421.1 + ] + }, + "SF0180@2": { + "IO": "SF0180", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2201", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 180254.6, + 271108.8 + ] + }, + "SF0181@2": { + "IO": "SF0181", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2201", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 180258.1, + 270841.7 + ] + }, + "SF0190@2": { + "IO": "SF0190", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2205", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 180258.1, + 268990.2 + ] + }, + "SF0191@2": { + "IO": "SF0191", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2205", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 180258.1, + 268720.2 + ] + }, + "SF0182@2": { + "IO": "SF0182", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2202", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 199578.6, + 271091.5 + ] + }, + "SF0183@2": { + "IO": "SF0183", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2202", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 199578.6, + 270828.9 + ] + }, + "SF0192@2": { + "IO": "SF0192", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2206", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 199578.6, + 268986.7 + ] + }, + "SF0193@2": { + "IO": "SF0193", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2206", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 199578.6, + 268716.7 + ] + }, + "SF0184@2": { + "IO": "SF0184", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2203", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211891.9, + 271316.7 + ] + }, + "SF0185@2": { + "IO": "SF0185", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2203", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211891.9, + 271046.7 + ] + }, + "SF0194@2": { + "IO": "SF0194", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2207", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211891.9, + 268989.1 + ] + }, + "SF0195@2": { + "IO": "SF0195", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2207", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211891.9, + 268708.0 + ] + }, + "SF0186@2": { + "IO": "SF0186", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2204", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234628.2, + 270827.6 + ] + }, + "SF0187@2": { + "IO": "SF0187", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2204", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234628.2, + 270557.6 + ] + }, + "SF0196@2": { + "IO": "SF0196", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2208", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234637.1, + 268607.9 + ] + }, + "SF0197@2": { + "IO": "SF0197", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2208", + "KENNZEICHNUNG": "=A01+UC022-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234637.1, + 268337.9 + ] + }, + "SF0240@2": { + "IO": "SF0240", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2301", + "KENNZEICHNUNG": "=A01+UC023-KF1DI2", + "TEXT-D": "Bereichshalt ", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181403.6, + 247644.3 + ] + }, + "SF0241@2": { + "IO": "SF0241", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2301", + "KENNZEICHNUNG": "=A01+UC023-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181407.1, + 247377.2 + ] + }, + "SF0242@2": { + "IO": "SF0242", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2302", + "KENNZEICHNUNG": "=A01+UC023-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200236.7, + 247725.2 + ] + }, + "SF0243@2": { + "IO": "SF0243", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2302", + "KENNZEICHNUNG": "=A01+UC023-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200236.7, + 247455.2 + ] + }, + "SF0247@2": { + "IO": "SF0247", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2304", + "KENNZEICHNUNG": "=A01+UC023-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235073.6, + 247355.2 + ] + }, + "FC0260@2": { + "IO": "FC0260", + "ID": "", + "VERW": "MS FC0260", + "BEZEICHNUNG": "MSS ausgelöst FC0260 (KR-M1303)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0260", + "TEXT-E": "MPCB triggered FC0260", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252961.6, + 248448.5 + ] + }, + "FC0262@2": { + "IO": "FC0262", + "ID": "", + "VERW": "MS FC0262", + "BEZEICHNUNG": "MSS ausgelöst FC0262 (CV-M1305)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0262", + "TEXT-E": "MPCB triggered FC0262", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252961.6, + 247901.5 + ] + }, + "FC0263@2": { + "IO": "FC0263", + "ID": "", + "VERW": "MS FC0263", + "BEZEICHNUNG": "MSS ausgelöst FC0263 (CV-M1306)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0263", + "TEXT-E": "MPCB triggered FC0263", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252961.6, + 247635.1 + ] + }, + "FC0261@2": { + "IO": "FC0261", + "ID": "", + "VERW": "MS FC0261", + "BEZEICHNUNG": "MSS ausgelöst FC0261 (KR-M1304)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0261", + "TEXT-E": "MPCB triggered FC0261", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252961.6, + 248178.5 + ] + }, + "FC0264@2": { + "IO": "FC0264", + "ID": "", + "VERW": "MS FC0264", + "BEZEICHNUNG": "MSS ausgelöst FC0264 (CV-M1307)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0264", + "TEXT-E": "MPCB triggered FC0264", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252961.6, + 247365.1 + ] + }, + "FC0266@2": { + "IO": "FC0266", + "ID": "", + "VERW": "MS FC0266", + "BEZEICHNUNG": "MSS ausgelöst FC0266 (CV-M1309)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0266", + "TEXT-E": "MPCB triggered FC0265", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252961.6, + 246825.1 + ] + }, + "SF0244@2": { + "IO": "SF0244", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2303", + "KENNZEICHNUNG": "=A01+UC023-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211226.6, + 247421.5 + ] + }, + "SF0245@2": { + "IO": "SF0245", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2303", + "KENNZEICHNUNG": "=A01+UC023-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211226.6, + 247151.5 + ] + }, + "SF1333@2": { + "IO": "SF1333", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ2303", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI01", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211226.6, + 246827.7 + ] + }, + "SF1337@2": { + "IO": "SF1337", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ2303", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI01", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211226.6, + 246557.7 + ] + }, + "FC0265@2": { + "IO": "FC0265", + "ID": "", + "VERW": "MS FC0265", + "BEZEICHNUNG": "MSS ausgelöst FC0265 (CV-M1308)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0265", + "TEXT-E": "MPCB triggered FC0265", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252961.6, + 247095.1 + ] + }, + "SF0124@2": { + "IO": "SF0124", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2103", + "KENNZEICHNUNG": "=A01+UC021-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 217828.3, + 311554.7 + ] + }, + "SF0125@2": { + "IO": "SF0125", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2103", + "KENNZEICHNUNG": "=A01+UC021-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 217828.3, + 311284.7 + ] + }, + "SF0126@2": { + "IO": "SF0126", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2104", + "KENNZEICHNUNG": "=A01+UC021-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234665.5, + 310572.7 + ] + }, + "SF0127@2": { + "IO": "SF0127", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ2104", + "KENNZEICHNUNG": "=A01+UC021-KF1DI2", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 234665.5, + 310302.7 + ] + }, + "DI0226@2": { + "IO": "DI0226", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv (QA1540/QA1541)", + "KENNZEICHNUNG": "=A01+UC023-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv (QA1540/QA1541)", + "TEXT-E": "Feedback 400V Main relay activ (QA1540/QA1541)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252980.7, + 251019.3 + ] + }, + "DI0165@2": { + "IO": "DI0165", + "ID": "9999", + "VERW": "24V OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC165)", + "KENNZEICHNUNG": "=A01+UC022-KF1DI1", + "TEXT-D": "Vorsicherung 24V OK (FC165)", + "TEXT-E": "Pre fuse 24V OK (FC165)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 266039.7 + ] + }, + "DI0174@2": { + "IO": "DI0174", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA1232/QA1233)", + "KENNZEICHNUNG": "=A01+UC022-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA1232/QA1233)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA1232/QA1233)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 264495.2 + ] + }, + "SF0781@2": { + "IO": "SF0781", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0X)", + "TEXT-E": "E-stop interace CH1 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252828.8, + 307781.1 + ] + }, + "SF0785@2": { + "IO": "SF0785", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC021-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0X)", + "TEXT-E": "E-stop interace CH2 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252828.8, + 307511.1 + ] + }, + "SF1091@2": { + "IO": "SF1091", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0X)", + "TEXT-E": "E-stop interace CH1 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 263894.7 + ] + }, + "SF1095@2": { + "IO": "SF1095", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC022-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0X)", + "TEXT-E": "E-stop interace CH2 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252687.9, + 263624.7 + ] + }, + "SF1401@2": { + "IO": "SF1401", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI02", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0X)", + "TEXT-E": "E-stop interace CH1 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252980.0, + 249581.9 + ] + }, + "SF1405@2": { + "IO": "SF1405", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC023-KF1FDI02", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0X)", + "TEXT-E": "E-stop interace CH2 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252980.0, + 249311.9 + ] + }, + "FC0062@2": { + "IO": "FC0062", + "ID": "", + "VERW": "MS FC0062", + "BEZEICHNUNG": "MSS ausgelöst FC0062 (KR-M1201)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI7", + "TEXT-D": "MSS ausgelöst FC0062", + "TEXT-E": "MPCB triggered FC0062", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252775.2, + 275000.0 + ] + }, + "FC0063@2": { + "IO": "FC0063", + "ID": "", + "VERW": "MS FC0063", + "BEZEICHNUNG": "MSS ausgelöst FC0063 (KR-M1202)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI7", + "TEXT-D": "MSS ausgelöst FC0063", + "TEXT-E": "MPCB triggered FC0063", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252775.2, + 274730.0 + ] + }, + "UC0204": { + "A": "0", + "B": "UC0204", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232673.1, + 290488.3 + ] + }, + "UC0208": { + "A": "0", + "B": "UC0208", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232666.3, + 289056.1 + ] + }, + "UC0209": { + "A": "0", + "B": "UC0209", + "C": "86623213910015374844", + "ARTINR": "829534306", + "BESCHR": "Camera DM280 m. Halter (ILS) - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244411.6, + 302469.9 + ] + }, + "UC2201": { + "A": "0", + "B": "UC2201", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178162.5, + 270974.4 + ] + }, + "UC2205": { + "A": "0", + "B": "UC2205", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 178164.5, + 268852.5 + ] + }, + "UC0210": { + "A": "0", + "B": "UC0210", + "C": "86623213910015374844", + "ARTINR": "829534306", + "BESCHR": "Camera DM280 m. Halter (ILS) - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 244411.6, + 284680.3 + ] + }, + "UC0211": { + "A": "0", + "B": "UC0211", + "C": "86623213910015374844", + "ARTINR": "829534306", + "BESCHR": "Camera DM280 m. Halter (ILS) - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 250495.3, + 293830.6 + ] + }, + "FC0076": { + "A": "0", + "B": "FC0076", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 255438.1, + 274066.5 + ] + }, + "PF0121@2": { + "IO": "PF0121", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2101", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 182019.9, + 310191.8 + ] + }, + "PF0120@2": { + "IO": "PF0120", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": " Betriebsbereit UZ2101", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 182019.9, + 310731.8 + ] + }, + "PF0100@2": { + "IO": "PF0100", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IL compressed air foult", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253453.3, + 312556.8 + ] + }, + "PF0101@2": { + "IO": "PF0101", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "IL Trouble motor protection swtich", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253453.3, + 312286.8 + ] + }, + "PF0102@2": { + "IO": "PF0102", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "IL fuse failure", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253453.3, + 312016.8 + ] + }, + "PF0160@2": { + "IO": "PF0160", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IL compressed air foult", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253430.4, + 269591.7 + ] + }, + "PF0161@2": { + "IO": "PF0161", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "IL Trouble motor protection swtich", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253430.4, + 269321.7 + ] + }, + "PF0162@2": { + "IO": "PF0162", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "IL Fuse failure", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253430.4, + 269051.7 + ] + }, + "PF0123@2": { + "IO": "PF0123", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2102", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200161.6, + 310338.9 + ] + }, + "PF0122@2": { + "IO": "PF0122", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2102", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200161.6, + 310878.9 + ] + }, + "PF0081@2": { + "IO": "PF0081", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0209", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ9", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 246292.9, + 300811.7 + ] + }, + "PF0080@2": { + "IO": "PF0080", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0209", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ9", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 246292.9, + 301351.7 + ] + }, + "PF0083@2": { + "IO": "PF0083", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0210", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ9", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 246242.8, + 282925.6 + ] + }, + "PF0082@2": { + "IO": "PF0082", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0210", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ9", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 246242.8, + 283465.6 + ] + }, + "PF0085@2": { + "IO": "PF0085", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0211", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ9", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 250931.1, + 299066.1 + ] + }, + "PF0084@2": { + "IO": "PF0084", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0211", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ9", + "TEXT-D": "Ready for use", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 250931.1, + 299606.1 + ] + }, + "PF0117@2": { + "IO": "PF0117", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "LDT Reset", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253453.3, + 312826.8 + ] + }, + "PF0177@2": { + "IO": "PF0177", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "LDT Reset", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ1", + "TEXT-D": "LDT Reset", + "TEXT-E": "IPB Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253430.4, + 268781.7 + ] + }, + "PF0220@2": { + "IO": "PF0220", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IL compressed air foult", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253722.5, + 254147.4 + ] + }, + "PF0221@2": { + "IO": "PF0221", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "IL Trouble motor protection swtich", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253738.4, + 253876.2 + ] + }, + "PF0222@2": { + "IO": "PF0222", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "IL Fuse failure", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253722.5, + 253607.4 + ] + }, + "PF0237@2": { + "IO": "PF0237", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "LDT Reset", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ1", + "TEXT-D": "Reset", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253722.5, + 254417.4 + ] + }, + "QA1540@2": { + "IO": "QA1540", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0260/QA0266)", + "KENNZEICHNUNG": "=A01+UC023-KF1FDQ01", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0260/QA0266)", + "TEXT-E": "Main contactor activate CH 1 (QA0260/QA0266)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253688.9, + 251290.5 + ] + }, + "QA1541@2": { + "IO": "QA1541", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0260/QA0266)", + "KENNZEICHNUNG": "=A01+UC023-KF1FDQ01", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0260/QA0266)", + "TEXT-E": "Main contactor activate CH 2 (QA0260/QA0266)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253723.2, + 250749.3 + ] + }, + "QA0920@2": { + "IO": "QA0920", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0140/QA0146)", + "KENNZEICHNUNG": "=A01+UC021-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0140/QA0146)", + "TEXT-E": "Main contactor activate CH 1 (QA0140/QA0146)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253562.3, + 309510.9 + ] + }, + "PF0047@2": { + "IO": "PF0047", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0204", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 239029.8, + 289722.1 + ] + }, + "PF0046@2": { + "IO": "PF0046", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0204", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 239025.0, + 290270.9 + ] + }, + "PF0057@2": { + "IO": "PF0057", + "ID": "9999", + "VERW": "IPB-GU-LED", + "BEZEICHNUNG": "Reset UZ0208", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235379.6, + 288709.6 + ] + }, + "PF0056@2": { + "IO": "PF0056", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0208", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235379.6, + 289248.4 + ] + }, + "PF0055@2": { + "IO": "PF0055", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0207", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 222432.6, + 289164.8 + ] + }, + "PF0054@2": { + "IO": "PF0054", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0207", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 222432.6, + 289704.8 + ] + }, + "PF0045@2": { + "IO": "PF0045", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0203", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 213384.9, + 290534.7 + ] + }, + "PF0044@2": { + "IO": "PF0044", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0203", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 213384.9, + 291074.7 + ] + }, + "PF0053@2": { + "IO": "PF0053", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0206", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200902.3, + 289186.9 + ] + }, + "PF0052@2": { + "IO": "PF0052", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0206", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200902.3, + 289726.9 + ] + }, + "PF0043@2": { + "IO": "PF0043", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0202", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 195860.2, + 290581.2 + ] + }, + "PF0042@2": { + "IO": "PF0042", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0202", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 195860.2, + 291121.2 + ] + }, + "PF0051@2": { + "IO": "PF0051", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0205", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 184609.8, + 289244.4 + ] + }, + "PF0050@2": { + "IO": "PF0050", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0205", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 184609.8, + 289784.4 + ] + }, + "PF0041@2": { + "IO": "PF0041", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0201", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181000.6, + 290421.1 + ] + }, + "PF0040@2": { + "IO": "PF0040", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0201", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181000.6, + 290961.1 + ] + }, + "PF0181@2": { + "IO": "PF0181", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2201", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181000.6, + 270841.7 + ] + }, + "PF0180@2": { + "IO": "PF0180", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2201", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181000.6, + 271381.7 + ] + }, + "PF0191@2": { + "IO": "PF0191", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2205", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181000.6, + 268720.2 + ] + }, + "PF0190@2": { + "IO": "PF0190", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2205", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 181000.6, + 269260.2 + ] + }, + "PF0183@2": { + "IO": "PF0183", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2202", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200321.1, + 270821.5 + ] + }, + "PF0182@2": { + "IO": "PF0182", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2202", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200321.1, + 271361.5 + ] + }, + "PF0193@2": { + "IO": "PF0193", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2206", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200321.1, + 268716.7 + ] + }, + "PF0192@2": { + "IO": "PF0192", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2206", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200321.1, + 269256.7 + ] + }, + "PF0184@2": { + "IO": "PF0184", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2203", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 212634.4, + 271586.7 + ] + }, + "PF0185@2": { + "IO": "PF0185", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2203", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 212634.4, + 271046.7 + ] + }, + "PF0195@2": { + "IO": "PF0195", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2207", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 212634.4, + 268708.0 + ] + }, + "PF0194@2": { + "IO": "PF0194", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2207", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 212634.4, + 269248.0 + ] + }, + "PF0187@2": { + "IO": "PF0187", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2204", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235370.7, + 270558.7 + ] + }, + "PF0186@2": { + "IO": "PF0186", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2204", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235370.7, + 271097.6 + ] + }, + "PF0197@2": { + "IO": "PF0197", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2208", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235379.6, + 268339.1 + ] + }, + "PF0196@2": { + "IO": "PF0196", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2208", + "KENNZEICHNUNG": "=A01+UC022-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235379.6, + 268877.9 + ] + }, + "PF0240@2": { + "IO": "PF0240", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2301", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ2", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 182149.6, + 247917.2 + ] + }, + "PF0241@2": { + "IO": "PF0241", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2301", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 182149.6, + 247377.2 + ] + }, + "PF0242@2": { + "IO": "PF0242", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2302", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200979.2, + 247995.2 + ] + }, + "PF0243@2": { + "IO": "PF0243", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2302", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 200979.2, + 247455.2 + ] + }, + "PF0246@2": { + "IO": "PF0246", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2304", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235816.1, + 247896.4 + ] + }, + "PF0247@2": { + "IO": "PF0247", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2304", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235816.1, + 247355.2 + ] + }, + "FC0262": { + "A": "0", + "B": "FC0262", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252692.7, + 398061.3 + ] + }, + "FC0266": { + "A": "0", + "B": "FC0266", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 252961.9, + 246971.6 + ] + }, + "PF0244@2": { + "IO": "PF0244", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2303", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211969.1, + 247691.5 + ] + }, + "PF0245@2": { + "IO": "PF0245", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2303", + "KENNZEICHNUNG": "=A01+UC023-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 211969.1, + 247151.5 + ] + }, + "PF0125@2": { + "IO": "PF0125", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2103", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 218570.8, + 311284.7 + ] + }, + "PF0124@2": { + "IO": "PF0124", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2103", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 218570.8, + 311824.7 + ] + }, + "PF0127@2": { + "IO": "PF0127", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ2104", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235408.0, + 310302.7 + ] + }, + "PF0126@2": { + "IO": "PF0126", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ2104", + "KENNZEICHNUNG": "=A01+UC021-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235408.0, + 310842.7 + ] + }, + "QA0921@2": { + "IO": "QA0921", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0140/QA0146)", + "KENNZEICHNUNG": "=A01+UC021-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0140/QA0146)", + "TEXT-E": "Main contactor activate CH 2 (QA0140/QA0146)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253571.3, + 308970.9 + ] + }, + "QA0922@2": { + "IO": "QA0922", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC021-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (zu UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253571.3, + 308630.9 + ] + }, + "QA0923@2": { + "IO": "QA0923", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC021-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (zu UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253571.3, + 308090.9 + ] + }, + "QA1542@2": { + "IO": "QA1542", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC023-KF1FDQ01", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (zu UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253704.1, + 250424.0 + ] + }, + "QA1543@2": { + "IO": "QA1543", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC023-KF1FDQ01", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (zu UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253704.1, + 249884.0 + ] + }, + "QA1230@2": { + "IO": "QA1230", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0200/QA203)", + "KENNZEICHNUNG": "=A01+UC022-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0200/QA203)", + "TEXT-E": "Main contactor activate CH 1 (QA0200/QA203)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253430.4, + 265634.7 + ] + }, + "QA1231@2": { + "IO": "QA1231", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0200/QA203)", + "KENNZEICHNUNG": "=A01+UC022-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0200/QA203)", + "TEXT-E": "Main contactor activate CH 2 (QA0200/QA203)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253430.4, + 265094.7 + ] + }, + "QA1232@2": { + "IO": "QA1232", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC022-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253412.0, + 264765.2 + ] + }, + "QA1233@2": { + "IO": "QA1233", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC022-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253412.0, + 264225.2 + ] + }, + "SF0000@2": { + "IO": "SF0000", + "ID": "9999", + "VERW": "PB-BK-NC", + "BEZEICHNUNG": "DT Anlage Aus ", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "DT Anlage Aus", + "TEXT-E": "System Off", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 288443.2 + ] + }, + "SF0001@2": { + "IO": "SF0001", + "ID": "9999", + "VERW": "IPB-GN-NO", + "BEZEICHNUNG": "LDT Anlage Ein", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "LDT Anlage Ein", + "TEXT-E": "System On", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 288173.2 + ] + }, + "SF0002@2": { + "IO": "SF0002", + "ID": "9999", + "VERW": "IPB-CL-NO", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "LDT Start nach Störung", + "TEXT-E": "LDT start after fault", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 287903.2 + ] + }, + "SF0003@2": { + "IO": "SF0003", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Lampentest", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Lampentest", + "TEXT-E": "Lamp test", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 287633.2 + ] + }, + "DI0005@2": { + "IO": "DI0005", + "ID": "9999", + "VERW": "RELAY-NO", + "BEZEICHNUNG": "Phasenausfall 400V", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Phasenausfall 400V", + "TEXT-E": "Phase failure relay 400V", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 284888.1 + ] + }, + "DI0006@2": { + "IO": "DI0006", + "ID": "9999", + "VERW": "400V-OK ", + "BEZEICHNUNG": "Vorsicherung 400V UC021", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Vorsicherung 400V UC021", + "TEXT-E": "Pre-fuse 400V UC021", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 284618.1 + ] + }, + "DI0007@2": { + "IO": "DI0007", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC022", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Vorsicherung 400V UC022", + "TEXT-E": "Pre-fuse 400V UC022", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 284348.1 + ] + }, + "DI0010@2": { + "IO": "DI0010", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC023", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Vorsicherung 400V UC023", + "TEXT-E": "Pre-fuse 400V UC023", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 284078.1 + ] + }, + "DI0011@2": { + "IO": "DI0011", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC Reserve", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Vorsicherung 400V Reserve", + "TEXT-E": "Pre-fuse 400V Reserve", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 283808.1 + ] + }, + "DI0012@2": { + "IO": "DI0012", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC Reserve", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Vorsicherung 400V Reserve", + "TEXT-E": "Pre-fuse 400V Reserve", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 283538.1 + ] + }, + "DI0013@2": { + "IO": "DI0013", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv", + "TEXT-E": "Feedback 400V Main relay activ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 279796.0 + ] + }, + "DI0014@2": { + "IO": "DI0014", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0660/QA0661)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 278680.3 + ] + }, + "DI0021@2": { + "IO": "DI0021", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC021)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC021)", + "TEXT-E": "Pre-fuse 24V OK (FC021)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 282940.8 + ] + }, + "DI0022@2": { + "IO": "DI0022", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC022)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC022)", + "TEXT-E": "Pre-fuse 24V OK (FC022)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 282670.8 + ] + }, + "DI0023@2": { + "IO": "DI0023", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC023)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC023)", + "TEXT-E": "Pre-fuse 24V OK (FC023)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 282400.8 + ] + }, + "DI0024@2": { + "IO": "DI0024", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC024)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC024)", + "TEXT-E": "Pre-fuse 24V OK (FC024)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 282130.8 + ] + }, + "DI0026@2": { + "IO": "DI0026", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC026)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC026)", + "TEXT-E": "Pre-fuse 24V OK (FC026)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 281590.8 + ] + }, + "SF0400@2": { + "IO": "SF0400", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UH02", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 286013.2 + ] + }, + "SF0404@2": { + "IO": "SF0404", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UH02", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 285743.2 + ] + }, + "DI0015@2": { + "IO": "DI0015", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0662/QA0663)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 277185.3 + ] + }, + "DI0016@2": { + "IO": "DI0016", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Sicherungsautomatenfall", + "KENNZEICHNUNG": "=A01+UH02-KF1DI1", + "TEXT-D": "Sicherungsautomatenfall", + "TEXT-E": "Circuit breaker case", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 283268.1 + ] + }, + "DI0025@2": { + "IO": "DI0025", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC025)", + "KENNZEICHNUNG": "=A01+UH02-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC025)", + "TEXT-E": "Pre-fuse 24V OK (FC025)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 281860.8 + ] + }, + "SF0541@2": { + "IO": "SF0541", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0x)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI8", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0x)", + "TEXT-E": "E-stop interace CH1 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 278060.1 + ] + }, + "SF0542@2": { + "IO": "SF0542", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0x)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI8", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0x)", + "TEXT-E": "E-stop interace CH2 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 277790.1 + ] + }, + "SF0545@2": { + "IO": "SF0545", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0x)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI8", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0x)", + "TEXT-E": "E-stop interace CH1 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 276566.5 + ] + }, + "SF0546@2": { + "IO": "SF0546", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0x)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDI8", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0x)", + "TEXT-E": "E-stop interace CH2 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 276296.5 + ] + }, + "DI0035@2": { + "IO": "DI0035", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"No fire alarm\"", + "KENNZEICHNUNG": "=A01+UH02-KF1DI2", + "TEXT-D": "IF BST \"No fire alarm\"", + "TEXT-E": "IF BST \"No fire alarm\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 281230.9 + ] + }, + "DI0036@2": { + "IO": "DI0036", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"Non fault\"", + "KENNZEICHNUNG": "=A01+UH02-KF1DI2", + "TEXT-D": "IF BST \"Non fault\"", + "TEXT-E": "IF BST \"Non fault\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 280960.9 + ] + }, + "DI0037@2": { + "IO": "DI0037", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"FPC opened\"", + "KENNZEICHNUNG": "=A01+UH02-KF1DI2", + "TEXT-D": "IF BST \"FPC opened\"", + "TEXT-E": "IF BST \"FPC opened\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252793.6, + 280690.9 + ] + }, + "PF0000@2": { + "IO": "PF0000", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Störung ", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ1", + "TEXT-D": "LM Störung", + "TEXT-E": "LM Trouble", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253536.1, + 287363.2 + ] + }, + "PF0001@2": { + "IO": "PF0001", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LDT Anlage Ein", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253536.1, + 288173.2 + ] + }, + "PF0002@2": { + "IO": "PF0002", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253536.1, + 287903.2 + ] + }, + "PF0003@2": { + "IO": "PF0003", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IL compressed air missing", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253536.1, + 287093.2 + ] + }, + "PF0004@2": { + "IO": "PF0004", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "LM motor protection has tripped", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253536.1, + 286823.2 + ] + }, + "PF0005@2": { + "IO": "PF0005", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "LM fuse has tripped", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253536.1, + 286553.2 + ] + }, + "PF0006@2": { + "IO": "PF0006", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Brandfall", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ1", + "TEXT-D": "LM Brandfall", + "TEXT-E": "LM Brand", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253536.1, + 286283.2 + ] + }, + "QA0610@2": { + "IO": "QA0610", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0060 - QA0067)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0060 - QA0067)", + "TEXT-E": "Main contactor activate CH 1 (QA0060 - QA0067)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253517.7, + 280336.0 + ] + }, + "QA0611@2": { + "IO": "QA0611", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0070 - QA0076)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0070 - QA0076)", + "TEXT-E": "Main contactor activate CH 1 (QA0070 - QA0076)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253517.7, + 280066.0 + ] + }, + "QA0612@2": { + "IO": "QA0612", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0060 - QA0067)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0060 - QA0067)", + "TEXT-E": "Main contactor activate CH 2 (QA0060 - QA0067)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253517.7, + 279526.0 + ] + }, + "QA0613@2": { + "IO": "QA0613", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0070 - QA0076)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0070 - QA0076)", + "TEXT-E": "Main contactor activate CH 2 (QA0070 - QA0076)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253517.7, + 279256.0 + ] + }, + "QA0660@2": { + "IO": "QA0660", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253517.7, + 278950.3 + ] + }, + "QA0661@2": { + "IO": "QA0661", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253517.7, + 278410.3 + ] + }, + "QA0662@2": { + "IO": "QA0662", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253517.7, + 277455.3 + ] + }, + "QA0663@2": { + "IO": "QA0663", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH02-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 253517.7, + 276915.3 + ] + }, + "PF0031@2": { + "IO": "PF0031", + "ID": "9999", + "VERW": "LED yellow", + "BEZEICHNUNG": "Signalsäule Gelb \" Störung\"", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ2", + "TEXT-D": "Signalsäule Gelb \" Störung\"", + "TEXT-E": "Signal tower yellow\" Trouble \" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 256074.3, + 290995.9 + ] + }, + "PF0030@2": { + "IO": "PF0030", + "ID": "9999", + "VERW": "LED red", + "BEZEICHNUNG": "Signalsäule Rot \" Störung\"", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ2", + "TEXT-D": "Signalsäule Rot \" Not-Halt\"", + "TEXT-E": "Signal tower red\" E-Stop\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 256074.3, + 290725.9 + ] + }, + "PF0032@2": { + "IO": "PF0032", + "ID": "9999", + "VERW": "LED green", + "BEZEICHNUNG": "Signalsäule Grün \" Betriebsbereit\"", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ2", + "TEXT-D": "Signalsäule Grün \" Betriebsbereit\"", + "TEXT-E": "Signal tower green\" System ready\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 256074.3, + 291265.9 + ] + }, + "PF0033@2": { + "IO": "PF0033", + "ID": "9999", + "VERW": "Hupe", + "BEZEICHNUNG": "Signalsäule 1 Hupe \" Anfahrwarnung\"", + "KENNZEICHNUNG": "=A01+UH02-KF1DQ2", + "TEXT-D": "Signalsäule Hupe \" Anfahrwarnung\"", + "TEXT-E": "Signal tower horn\" Restart warning\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 256074.3, + 291535.9 + ] + }, + "SF0246@2": { + "IO": "SF0246", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ2304", + "KENNZEICHNUNG": "=A01+UC023-KF1DI2", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 235072.7, + 247630.6 + ] + }, + "FC0061@1": { + "IO": "FC0061", + "ID": "", + "VERW": "MS FC0061", + "BEZEICHNUNG": "MSS ausgelöst FC0061", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0061", + "TEXT-E": "MPCB triggered FC0061", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327898.7, + 131901.4 + ] + }, + "FC0057@1": { + "IO": "FC0057", + "ID": "", + "VERW": "MS FC0057", + "BEZEICHNUNG": "MSS ausgelöst FC0057", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0057", + "TEXT-E": "MPCB triggered FC0057", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327898.7, + 132441.4 + ] + }, + "SF0000@1": { + "IO": "SF0000", + "ID": "9999", + "VERW": "PB-BK-NC", + "BEZEICHNUNG": "DT Anlage Aus ", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "DT Anlage Aus", + "TEXT-E": "PB System OFF", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 145855.2 + ] + }, + "SF0001@1": { + "IO": "SF0001", + "ID": "9999", + "VERW": "IPB-GN-NO", + "BEZEICHNUNG": "LDT Anlage Ein", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "LDT Anlage Ein", + "TEXT-E": "IPB System ON", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 145585.2 + ] + }, + "SF0002@1": { + "IO": "SF0002", + "ID": "9999", + "VERW": "IPB-CL-NO", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "LDT Start nach Störung", + "TEXT-E": "IPB Start after Trouble", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 145315.2 + ] + }, + "SF0003@1": { + "IO": "SF0003", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Lampentest", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Lampentest", + "TEXT-E": "Lamp test", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 145045.2 + ] + }, + "DI0005@1": { + "IO": "DI0005", + "ID": "9999", + "VERW": "RELAY-NO", + "BEZEICHNUNG": "Phasenausfall 400V", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Phasenausfall 400V", + "TEXT-E": "Phase failure relay 400V", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 141779.9 + ] + }, + "DI0006@1": { + "IO": "DI0006", + "ID": "9999", + "VERW": "400V-OK ", + "BEZEICHNUNG": "Vorsicherung 400V UC0110", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Vorsicherung 400V UC0110", + "TEXT-E": "Pre-fuse 400V UC0110", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 141509.9 + ] + }, + "DI0007@1": { + "IO": "DI0007", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC0111", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Vorsicherung 400V UC0111", + "TEXT-E": "Pre-fuse 400V UC0111", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 141239.9 + ] + }, + "DI0010@1": { + "IO": "DI0010", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC011", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Vorsicherung 400V UC011", + "TEXT-E": "Pre-fuse 400V UC011", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 140969.9 + ] + }, + "DI0011@1": { + "IO": "DI0011", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv +UZ0110", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv +UZ0110", + "TEXT-E": "Feedback main contactor active +UZ0110", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 134559.7 + ] + }, + "DI0012@1": { + "IO": "DI0012", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv +UZ0111", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv +UZ0111", + "TEXT-E": "Feedback main contactor active +UZ0111", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 133619.8 + ] + }, + "DI0021@1": { + "IO": "DI0021", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC021)", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC021)", + "TEXT-E": "Pre-fuse 24V OK (FC021)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 140055.7 + ] + }, + "DI0022@1": { + "IO": "DI0022", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC022)", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC022)", + "TEXT-E": "Pre-fuse 24V OK (FC022)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 139785.7 + ] + }, + "DI0023@1": { + "IO": "DI0023", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC023)", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC023)", + "TEXT-E": "Pre-fuse 24V OK (FC023)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 139515.7 + ] + }, + "DI0024@1": { + "IO": "DI0024", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC024)", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC024)", + "TEXT-E": "Pre-fuse 24V OK (FC024)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 139245.7 + ] + }, + "SF0400@1": { + "IO": "SF0400", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UH01", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI5", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 142885.2 + ] + }, + "SF0404@1": { + "IO": "SF0404", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UH01", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI5", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 142615.2 + ] + }, + "DI0016@1": { + "IO": "DI0016", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Vorsicherung 400V", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Vorsicherung 400V", + "TEXT-E": "Back-up fuse 400V", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 140649.8 + ] + }, + "FC0060@1": { + "IO": "FC0060", + "ID": "", + "VERW": "MS FC0060", + "BEZEICHNUNG": "MSS ausgelöst FC0060", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0060", + "TEXT-E": "MPCB triggered FC0060", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327898.7, + 132171.4 + ] + }, + "FC0067@1": { + "IO": "FC0067", + "ID": "", + "VERW": "MS FC0067", + "BEZEICHNUNG": "MSS ausgelöst FC0067", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0067", + "TEXT-E": "MPCB triggered FC0067", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330187.6, + 131557.5 + ] + }, + "DI0035@1": { + "IO": "DI0035", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"No fire alarm\"", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "IF BST \"Kein Feueralarm\"", + "TEXT-E": "IF BST \"No fire alarm\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 138916.2 + ] + }, + "DI0036@1": { + "IO": "DI0036", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"Non fault\"", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "IF BST \"Keine Störung\"", + "TEXT-E": "IF BST \"Non fault\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 138646.2 + ] + }, + "DI0037@1": { + "IO": "DI0037", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"FPC opened\"", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "IF BST \"FPC geöffnet\"", + "TEXT-E": "IF BST \"FPC opened\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 138376.2 + ] + }, + "SF0471@1": { + "IO": "SF0471", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (aus UH0x)", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI6", + "TEXT-D": "Not Halt Schnittstelle CH1 (aus UH0x)", + "TEXT-E": "E-stop interace CH1 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 135629.7 + ] + }, + "SF0475@1": { + "IO": "SF0475", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (aus UH0x)", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI6", + "TEXT-D": "Not Halt Schnittstelle CH2 (aus UH0x)", + "TEXT-E": "E-stop interace CH2 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 135359.7 + ] + }, + "FC0064@1": { + "IO": "FC0064", + "ID": "", + "VERW": "MS FC0064", + "BEZEICHNUNG": "MSS ausgelöst FC0064", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0064", + "TEXT-E": "MPCB triggered FC0064", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330179.0, + 132367.5 + ] + }, + "FC0062@1": { + "IO": "FC0062", + "ID": "", + "VERW": "MS FC0062", + "BEZEICHNUNG": "MSS ausgelöst FC0062 (ILS-CV-M0103)", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "", + "TEXT-E": "MPCB triggered FC0062", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327898.7, + 131631.4 + ] + }, + "FC0065@1": { + "IO": "FC0065", + "ID": "", + "VERW": "MS FC0065", + "BEZEICHNUNG": "MSS ausgelöst FC0065", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "", + "TEXT-E": "MPCB triggered FC0065", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330179.6, + 132097.5 + ] + }, + "FC0057": { + "A": "0", + "B": "FC0057", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 327899.1, + 132587.9 + ] + }, + "PF0000@1": { + "IO": "PF0000", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Störung ", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ1", + "TEXT-D": "LM Störung ", + "TEXT-E": "IL Trouble", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328659.6, + 144235.2 + ] + }, + "PF0001@1": { + "IO": "PF0001", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LDT Anlage Ein", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328659.6, + 145585.2 + ] + }, + "PF0002@1": { + "IO": "PF0002", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328659.6, + 145315.2 + ] + }, + "PF0003@1": { + "IO": "PF0003", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IB Pneumatic Pressure Loss", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328659.6, + 143965.2 + ] + }, + "PF0004@1": { + "IO": "PF0004", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "LM motor protection has tripped", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328659.6, + 143695.2 + ] + }, + "PF0005@1": { + "IO": "PF0005", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "LM fuse has tripped", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328659.6, + 143425.2 + ] + }, + "PF0006@1": { + "IO": "PF0006", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Brandfall", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ1", + "TEXT-D": "LM Brandfall", + "TEXT-E": "LM-Brand", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328659.6, + 143155.2 + ] + }, + "QA0012@1": { + "IO": "QA0012", + "ID": "9999", + "VERW": "IF-E-STOP C1", + "BEZEICHNUNG": "Schütz Beleuchtung Ladeschleife 1", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ1", + "TEXT-D": "Schütz Beleuchtung Ladeschleife 1", + "TEXT-E": "Contactor lighting Loading boom 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328659.6, + 138071.8 + ] + }, + "QA0013@1": { + "IO": "QA0013", + "ID": "9999", + "VERW": "IF-E-STOP C2", + "BEZEICHNUNG": "Schütz Beleuchtung Ladeschleife 2", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ1", + "TEXT-D": "Schütz Beleuchtung Ladeschleife 2", + "TEXT-E": "Contactor lighting Loading boom 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328659.6, + 137801.8 + ] + }, + "QA0660@1": { + "IO": "QA0660", + "ID": "9999", + "VERW": "IF-E-STOP C1", + "BEZEICHNUNG": "Hauptschütze +UC0110", + "KENNZEICHNUNG": "=A01+UH01-KF1FDQ7", + "TEXT-D": "Hauptschütze +UC0110", + "TEXT-E": "Main contactor +UC0110", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328641.2, + 134829.7 + ] + }, + "QA0661@1": { + "IO": "QA0661", + "ID": "9999", + "VERW": "IF-E-STOP C2", + "BEZEICHNUNG": "Hauptschütze +UC0110", + "KENNZEICHNUNG": "=A01+UH01-KF1FDQ7", + "TEXT-D": "Hauptschütze +UC0110", + "TEXT-E": "Main contactor +UC0110", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328641.2, + 134289.7 + ] + }, + "QA0662@1": { + "IO": "QA0662", + "ID": "9999", + "VERW": "IF-E-STOP C1", + "BEZEICHNUNG": "Hauptschütze +UC0111", + "KENNZEICHNUNG": "=A01+UH01-KF1FDQ7", + "TEXT-D": "Hauptschütze +UC0111", + "TEXT-E": "Main contactor +UC0111", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328641.2, + 133889.8 + ] + }, + "QA0663@1": { + "IO": "QA0663", + "ID": "9999", + "VERW": "IF-E-STOP C2", + "BEZEICHNUNG": "Hauptschütze +UC0111", + "KENNZEICHNUNG": "=A01+UH01-KF1FDQ7", + "TEXT-D": "Hauptschütze +UC0111", + "TEXT-E": "Main contactor +UC0111", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328641.2, + 133349.8 + ] + }, + "PF0021@1": { + "IO": "PF0021", + "ID": "9999", + "VERW": "LED yellow", + "BEZEICHNUNG": "Signalsäule gelb \" Störung\"", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ2", + "TEXT-D": "Signalsäule gelb \" Störung\"", + "TEXT-E": "Signal tower yellow\" Trouble \" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 334497.8, + 146035.2 + ] + }, + "PF0020@1": { + "IO": "PF0020", + "ID": "9999", + "VERW": "LED red", + "BEZEICHNUNG": "Signalsäule rot \" Betrieb\"", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ2", + "TEXT-D": "Signalsäule rot \" Betrieb\"", + "TEXT-E": "Signal tower rot \" E-Stop\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 334497.8, + 145765.2 + ] + }, + "PF0022@1": { + "IO": "PF0022", + "ID": "9999", + "VERW": "LED green", + "BEZEICHNUNG": "Signalsäule grün \" Betriebsbereit\"", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ2", + "TEXT-D": "Signalsäule grün \" Betriebsbereit\"", + "TEXT-E": "Signal tower green\" System ready\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 334497.8, + 146305.2 + ] + }, + "PF0023@1": { + "IO": "PF0023", + "ID": "9999", + "VERW": "Hupe", + "BEZEICHNUNG": "Signalsäule Hupe \" Anfahrwarnung\"", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ2", + "TEXT-D": "Signalsäule Hupe \" Anfahrwarnung\"", + "TEXT-E": "Signal tower horn\" Restart warning\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 334497.8, + 146575.2 + ] + }, + "SF0025@1": { + "IO": "SF0025", + "ID": "9999", + "VERW": "Key switch LB1", + "BEZEICHNUNG": "Schlüsselschalter LS 1 ", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "Schlüsselschalter LS 1 ", + "TEXT-E": "Key switch LB 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 144775.2 + ] + }, + "SF0026@1": { + "IO": "SF0026", + "ID": "9999", + "VERW": "Key switch LB2", + "BEZEICHNUNG": "Schlüsselschalter LS 2", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "Schlüsselschalter LS 2", + "TEXT-E": "Key switch LB 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 144505.2 + ] + }, + "DI0017@1": { + "IO": "DI0017", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Sicherung Lampe 1EA0012 & 1EA0013", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Sicherung Lampe 1EA0012 & 1EA0013", + "TEXT-E": "Fuse lamp 1EA0012 & 1EA0013", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 140379.8 + ] + }, + "FC0063@1": { + "IO": "FC0063", + "ID": "", + "VERW": "MS FC0063", + "BEZEICHNUNG": "MSS ausgelöst FC0063 (ILS-CV-M0105)", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0063 LS 1", + "TEXT-E": "MPCB triggered FC0063", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327898.7, + 131361.4 + ] + }, + "FC0066@1": { + "IO": "FC0066", + "ID": "", + "VERW": "MS FC0066", + "BEZEICHNUNG": "MSS ausgelöst FC0066", + "KENNZEICHNUNG": "=A01+UH01-KF1DI5", + "TEXT-D": "MSS ausgelöst FC0066", + "TEXT-E": "MPCB triggered FC0066", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330198.7, + 131833.0 + ] + }, + "FC0320@1": { + "IO": "FC0320", + "ID": "", + "VERW": "MS FC0320", + "BEZEICHNUNG": "MSS ausgelöst FC0320 Kreisel", + "KENNZEICHNUNG": "=A01+UC0110KF1DI3", + "TEXT-D": "MSS ausgelöst FC0320 Kreisel", + "TEXT-E": "MPCB triggered FC0320 circle", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 373091.7, + 183202.0 + ] + }, + "FC0320": { + "A": "0", + "B": "FC0320", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 373092.0, + 183348.5 + ] + }, + "FC0380@1": { + "IO": "FC0380", + "ID": "", + "VERW": "MS FC0380", + "BEZEICHNUNG": "MSS ausgelöst FC0380 Kreisel", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0380 Kreisel", + "TEXT-E": "Motor circuit-breaker signalling contact FC0380", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 379125.8, + 183202.0 + ] + }, + "FC0380": { + "A": "0", + "B": "FC0380", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 379126.2, + 183348.5 + ] + }, + "FC0381@1": { + "IO": "FC0381", + "ID": "", + "VERW": "MS FC0381", + "BEZEICHNUNG": "MSS ausgelöst FC0381 Stützfuß LS2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 376298.4, + 185541.6 + ] + }, + "FC0381": { + "A": "0", + "B": "FC0381", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 376298.7, + 185688.1 + ] + }, + "DQ0382@1": { + "IO": "DQ0382", + "ID": "9999", + "VERW": "M0382 UP", + "BEZEICHNUNG": "Motor MA0381 Stutzfuß aufwärts LS2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 377040.9, + 185823.5 + ] + }, + "DQ0382": { + "A": "0", + "B": "DQ0382", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 377041.2, + 185958.1 + ] + }, + "SF0330@1": { + "IO": "SF0330", + "ID": "9999", + "VERW": "IPB-CL-NO", + "BEZEICHNUNG": "Ladeschleife einfahren UZ0110-2", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI3", + "TEXT-D": "Ladeschleife einfahren UZ0110-2", + "TEXT-E": "Loading Boom entry UZ0110-2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 369792.1, + 190979.9 + ] + }, + "SF1640@1": { + "IO": "SF1640", + "ID": "9999", + "VERW": "MPB-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0110-1", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI8", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 372721.9, + 190656.1 + ] + }, + "SF0332@1": { + "IO": "SF0332", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Freigabe MT ausfahren UZ0110-2", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI3", + "TEXT-D": "Freigabe MT UZ0110-2", + "TEXT-E": "Release MT UZ0110-2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 369792.1, + 190439.9 + ] + }, + "FC0070@1": { + "IO": "FC0070", + "ID": "", + "VERW": "MS FC0070", + "BEZEICHNUNG": "MSS ausgelöst FC0070", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0070", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 370718.9, + 181454.1 + ] + }, + "QA0071@1": { + "IO": "QA0071", + "ID": "9999", + "VERW": "M0071 0,18", + "BEZEICHNUNG": "Motor 1 MA0071 Ausfahren LS 1", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor 1 MA0071 Ausfahren LS 1", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 370718.9, + 180916.8 + ] + }, + "FC0072@1": { + "IO": "FC0072", + "ID": "", + "VERW": "MS FC0072", + "BEZEICHNUNG": "MSS ausgelöst FC0072", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0072", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 370718.9, + 180570.0 + ] + }, + "QA0073@1": { + "IO": "QA0073", + "ID": "9999", + "VERW": "M0073 0,18", + "BEZEICHNUNG": "Motor 2 MA0073 Ausfahren LS 1", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor 2 MA0073 Ausfahren LS 1", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 370718.9, + 180032.7 + ] + }, + "FC0074@1": { + "IO": "FC0074", + "ID": "", + "VERW": "MS FC0074", + "BEZEICHNUNG": "MSS ausgelöst FC0074", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0074", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 376718.9, + 181454.1 + ] + }, + "QA0075@1": { + "IO": "QA0075", + "ID": "9999", + "VERW": "M0075 0,12", + "BEZEICHNUNG": "Motor 1 MA0075 Ausfahren LS 2", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor 1 MA0075 Ausfahren LS 2", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 376718.9, + 180916.8 + ] + }, + "FC0076@1": { + "IO": "FC0076", + "ID": "", + "VERW": "MS FC0076", + "BEZEICHNUNG": "MSS ausgelöst FC0076", + "KENNZEICHNUNG": "=A01+UH01-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0076", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 376718.9, + 180570.0 + ] + }, + "QA0077@1": { + "IO": "QA0077", + "ID": "9999", + "VERW": "M0077 0,12", + "BEZEICHNUNG": "Motor 2 MA0077 Ausfahren LS 2", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ4", + "TEXT-D": "Motor 2 MA0077 Ausfahren LS 2", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 376718.9, + 180032.7 + ] + }, + "SF0331@1": { + "IO": "SF0331", + "ID": "9999", + "VERW": "PB-BL-NO", + "BEZEICHNUNG": "Ladeschleife ausfahren UZ0110-2", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI3", + "TEXT-D": "Ladeschleife ausfahren UZ0110-2", + "TEXT-E": "Loading Boom exit UZ0110-2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 369792.1, + 190709.9 + ] + }, + "SF0306@1": { + "IO": "SF0306", + "ID": "9999", + "VERW": "SSW-BL-NO", + "BEZEICHNUNG": "Beladeposition 2", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI2", + "TEXT-D": "Beladeposition 2", + "TEXT-E": "Loading position 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 372721.9, + 190926.1 + ] + }, + "SF0305@1": { + "IO": "SF0305", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Freigabe MT UZ0110-1", + "KENNZEICHNUNG": "=A01+UC0110KF1DI2", + "TEXT-D": "Freigabe MT", + "TEXT-E": "Release MT", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 372721.9, + 191196.1 + ] + }, + "SF1644@1": { + "IO": "SF1644", + "ID": "9999", + "VERW": "MPB-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0110-1", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI8", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 372721.9, + 190386.1 + ] + }, + "FC0321@1": { + "IO": "FC0321", + "ID": "", + "VERW": "MS FC0321", + "BEZEICHNUNG": "MSS ausgelöst FC0321 Stützfuß LS1", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0321 Stützfuß LS1", + "TEXT-E": "MPCB triggered FC0321 Support foot LS1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 370318.0, + 185480.0 + ] + }, + "FC0321": { + "A": "0", + "B": "FC0321", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 370318.3, + 185626.5 + ] + }, + "DQ0322@1": { + "IO": "DQ0322", + "ID": "9999", + "VERW": "M0321_UP", + "BEZEICHNUNG": "Motor MA0321 Stutzfuß aufwärts LS1", + "KENNZEICHNUNG": "=A01+UC0110KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 371060.5, + 185761.9 + ] + }, + "DQ0142": { + "A": "0", + "B": "DQ0142", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 371060.8, + 185356.5 + ] + }, + "SF0322@1": { + "IO": "SF0322", + "ID": "", + "VERW": "position down", + "BEZEICHNUNG": "Stützfuß hat Endlage unten erreicht", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1", + "pos": [ + 373092.7, + 186148.0 + ] + }, + "SF0323@1": { + "IO": "SF0323", + "ID": "", + "VERW": "Top position", + "BEZEICHNUNG": "Stützfuß hat Endlage oben erreicht", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1", + "pos": [ + 373092.7, + 185878.0 + ] + }, + "SF0333@1": { + "IO": "SF0333", + "ID": "9999", + "VERW": "KN-1-0-2", + "BEZEICHNUNG": "Stützfuß ab LS1", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI3", + "TEXT-D": "Stützfuß ab LS1", + "TEXT-E": "Support foot down LS1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 370170.0, + 186556.6 + ] + }, + "SF0334@1": { + "IO": "SF0334", + "ID": "9999", + "VERW": "KN-1-0-2", + "BEZEICHNUNG": "Stützfuß auf LS1", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI3", + "TEXT-D": "Stützfuß auf LS1", + "TEXT-E": "Support foot up LS1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 370170.0, + 186286.6 + ] + }, + "PF0330@1": { + "IO": "PF0330", + "ID": "9999", + "VERW": "IPB-CL-LED", + "BEZEICHNUNG": "Ladeschleife einfahren UZ0110-2", + "KENNZEICHNUNG": "=A01+UC0110-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 370534.6, + 190979.9 + ] + }, + "SF0051@1": { + "IO": "SF0051", + "ID": "", + "VERW": "LS 1 extended", + "BEZEICHNUNG": "Positionsschalter Ladeschleife 1 ausgefahren", + "KENNZEICHNUNG": "=A01+UH01-KF1DI3", + "TEXT-D": "Positionsschalter Ladeschleife 1 ausgefahren", + "TEXT-E": "Position switch loading boom 1 extended", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1", + "pos": [ + 370715.4, + 179158.7 + ] + }, + "SF0050@1": { + "IO": "SF0050", + "ID": "", + "VERW": "LS 1 retracted", + "BEZEICHNUNG": "Positionsschalter Ladeschleife 1 eingefahren", + "KENNZEICHNUNG": "=A01+UH01-KF1DI3", + "TEXT-D": "Positionsschalter Ladeschleife 1 eingefahren", + "TEXT-E": "Switch for loading boom 1 position retracted", + "TEXT-ES": "", + "TEXT-F": "M12-0° 5m", + "SPS": "1", + "pos": [ + 370715.4, + 178888.7 + ] + }, + "SF0390@1": { + "IO": "SF0390", + "ID": "9999", + "VERW": "IPB-CL-NO", + "BEZEICHNUNG": "Ladeschleife einfahren UZ0111-2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI3", + "TEXT-D": "Ladeschleife einfahren UZ0111-2", + "TEXT-E": "Loading Boom entry UZ0111-2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 375754.2, + 190980.5 + ] + }, + "SF1950@1": { + "IO": "SF1950", + "ID": "9999", + "VERW": "MPB-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0111-1", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI9", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 378698.6, + 190656.7 + ] + }, + "SF0392@1": { + "IO": "SF0392", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Freigabe MT UZ0111-2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI3", + "TEXT-D": "Freigabe MT UZ0111-2 ", + "TEXT-E": "Loaded MT UZ0111-2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 375754.2, + 190440.5 + ] + }, + "SF0391@1": { + "IO": "SF0391", + "ID": "9999", + "VERW": "PB-BL-NO", + "BEZEICHNUNG": "Ladeschleife ausfahren UZ0111-2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI3", + "TEXT-D": "Ladeschleife ausfahren UZ0111-2", + "TEXT-E": "Loading Boom exit UZ0111-2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 375754.2, + 190710.5 + ] + }, + "SF0366@1": { + "IO": "SF0366", + "ID": "9999", + "VERW": "SSW-BL-NO", + "BEZEICHNUNG": "Beladeposition 2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI2", + "TEXT-D": "Beladeposition 2", + "TEXT-E": "Loading Position 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 378698.6, + 190926.7 + ] + }, + "SF0365@1": { + "IO": "SF0365", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Freigabe MT UZ0111-1", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI2", + "TEXT-D": "Freigabe MT", + "TEXT-E": "Release MT", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 378698.6, + 191196.7 + ] + }, + "SF1954@1": { + "IO": "SF1954", + "ID": "9999", + "VERW": "MPB-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0111-1", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI9", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 378698.6, + 190386.7 + ] + }, + "PF0390@1": { + "IO": "PF0390", + "ID": "9999", + "VERW": "IPB-CL-LED", + "BEZEICHNUNG": "Ladeschleife einfahren UZ0111-2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 376496.7, + 190980.5 + ] + }, + "SF0393@1": { + "IO": "SF0393", + "ID": "9999", + "VERW": "KN-1-0-2", + "BEZEICHNUNG": "Stützfuß ab LS2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI3", + "TEXT-D": "Stützfuß ab LS2", + "TEXT-E": "Support foot down LS2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 376203.0, + 186556.6 + ] + }, + "SF0394@1": { + "IO": "SF0394", + "ID": "9999", + "VERW": "KN-1-0-2", + "BEZEICHNUNG": "Stützfuß auf LS2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI3", + "TEXT-D": "Stützfuß auf LS2", + "TEXT-E": "Support foot up LS2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 376203.0, + 186286.6 + ] + }, + "SF0382@1": { + "IO": "SF0382", + "ID": "", + "VERW": "position down", + "BEZEICHNUNG": "Stützfuß hat Endlage unten erreicht", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1", + "pos": [ + 379126.8, + 186147.4 + ] + }, + "SF0383@1": { + "IO": "SF0383", + "ID": "", + "VERW": "Top position", + "BEZEICHNUNG": "Stützfuß hat Endlage oben erreicht", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "M12-0° 10m", + "SPS": "1", + "pos": [ + 379126.8, + 185877.4 + ] + }, + "SF1641@1": { + "IO": "SF1641", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Schaltleiste LS1 hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI8", + "TEXT-D": "Schaltleiste LS1 hat ausgelöst", + "TEXT-E": "Safety edge LS1 has triggered", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 373110.1, + 188189.6 + ] + }, + "SF1645@1": { + "IO": "SF1645", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Schaltleiste LS1 hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI8", + "TEXT-D": "Schaltleiste LS1 hat ausgelöst", + "TEXT-E": "Safety edge LS1 has triggered", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 373110.1, + 187919.6 + ] + }, + "SF1951@1": { + "IO": "SF1951", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Schaltleiste LS2 hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI9", + "TEXT-D": "Schaltleiste LS2 hat ausgelöst", + "TEXT-E": "Safety edge LS2 has triggered", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 379318.6, + 188189.6 + ] + }, + "SF1955@1": { + "IO": "SF1955", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Schaltleiste LS2 hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI9", + "TEXT-D": "Schaltleiste LS2 hat ausgelöst", + "TEXT-E": "Safety edge LS2 has triggered", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 379318.6, + 187919.6 + ] + }, + "DI0327@1": { + "IO": "DI0327", + "ID": "", + "VERW": "OK LS 1", + "BEZEICHNUNG": " SEW MOVIMOT OK LS1", + "KENNZEICHNUNG": "=A01+UC0110-KF1DI3", + "TEXT-D": " SEW MOVIMOT OK LS1", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 371060.2, + 184946.7 + ] + }, + "DI0327": { + "A": "0", + "B": "DI0327", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 371060.8, + 185086.5 + ] + }, + "DI0387@1": { + "IO": "DI0387", + "ID": "", + "VERW": "OK LS 2", + "BEZEICHNUNG": " SEW MOVIMOT OK LS2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DI3", + "TEXT-D": " SEW MOVIMOT OK LS2", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 377040.6, + 185008.4 + ] + }, + "DI0387": { + "A": "0", + "B": "DI0387", + "C": "20073710081010151939", + "ARTINR": "720002003", + "BESCHR": "SENSOR INDUKTIV M18/12MM/150KABEL-ST-M12", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 377041.2, + 185148.1 + ] + }, + "PF0287@1": { + "IO": "PF0287", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Midi-Aufbauleuchten Gelb", + "KENNZEICHNUNG": "=A01+UC0110-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 373110.1, + 188509.3 + ] + }, + "DQ0323@1": { + "IO": "DQ0323", + "ID": "9999", + "VERW": "M0321_DOWN", + "BEZEICHNUNG": "Motor MA0321 Stutzfuß abwärts LS1", + "KENNZEICHNUNG": "=A01+UC0110KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 371060.5, + 185491.9 + ] + }, + "DQ0324@1": { + "IO": "DQ0324", + "ID": "9999", + "VERW": "Creep speed LS1", + "BEZEICHNUNG": "Motor MA0321 Kriechgang LS1", + "KENNZEICHNUNG": "=A01+UC0110KF1DQ3", + "TEXT-D": "Motor MA0321 Kriechgang LS1", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 371060.5, + 185221.9 + ] + }, + "DQ0383@1": { + "IO": "DQ0383", + "ID": "9999", + "VERW": "M0383 DOWN", + "BEZEICHNUNG": "Motor MA0381 Stutzfuß abwärts LS2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 377040.9, + 185553.5 + ] + }, + "DQ0383": { + "A": "0", + "B": "DQ0383", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 377041.2, + 185688.1 + ] + }, + "DQ0384@1": { + "IO": "DQ0384", + "ID": "9999", + "VERW": "M0384 DOWN", + "BEZEICHNUNG": "Motor MA0381 Kriechgang LS2", + "KENNZEICHNUNG": "=A01+UC0111-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 377040.9, + 185283.5 + ] + }, + "DQ0384": { + "A": "0", + "B": "DQ0384", + "C": "20073710081010151939", + "ARTINR": "790902001", + "BESCHR": "E-Teile für SEW Motor ASE1/HAN10ES - BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 377041.2, + 185418.1 + ] + }, + "PF0347@1": { + "IO": "PF0347", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Midi-Aufbauleuchten Gelb", + "KENNZEICHNUNG": "=A01+UC0111-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 379318.6, + 188498.5 + ] + }, + "FC0262@3": { + "IO": "FC0262", + "ID": "", + "VERW": "MS FC0262", + "BEZEICHNUNG": "MSS ausgelöst FC0262 (CV-M2305)", + "KENNZEICHNUNG": "=A01+UC033-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0262", + "TEXT-E": "MPCB triggered FC0262", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252692.4, + 397907.9 + ] + }, + "FC0062@5": { + "IO": "FC0062", + "ID": "", + "VERW": "MS FC0062", + "BEZEICHNUNG": "MSS ausgelöst FC0062", + "KENNZEICHNUNG": "=A01+UH05-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0062", + "TEXT-E": "MPCB triggered FC0062", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210934.6, + 135723.4 + ] + }, + "SF0000@5": { + "IO": "SF0000", + "ID": "9999", + "VERW": "PB-BK-NC", + "BEZEICHNUNG": "DT Anlage Aus ", + "KENNZEICHNUNG": "=A01+UH05-KF1DI1", + "TEXT-D": "DT Anlage Aus", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 147711.2 + ] + }, + "SF0001@5": { + "IO": "SF0001", + "ID": "9999", + "VERW": "IPB-GN-NO", + "BEZEICHNUNG": "LDT Anlage Ein", + "KENNZEICHNUNG": "=A01+UH05-KF1DI1", + "TEXT-D": "LDT Anlage Ein", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 147441.2 + ] + }, + "SF0002@5": { + "IO": "SF0002", + "ID": "9999", + "VERW": "IPB-CL-NO", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UH05-KF1DI1", + "TEXT-D": "LDT Start nach Störung", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 147171.2 + ] + }, + "SF0003@5": { + "IO": "SF0003", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Lampentest", + "KENNZEICHNUNG": "=A01+UH05-KF1DI1", + "TEXT-D": "Lampentest", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 146901.2 + ] + }, + "DI0005@5": { + "IO": "DI0005", + "ID": "9999", + "VERW": "RELAY-NO", + "BEZEICHNUNG": "Phasenausfall 400V", + "KENNZEICHNUNG": "=A01+UH05-KF1DI1", + "TEXT-D": "Phasenausfall 400V", + "TEXT-E": "Phase failure relay 400V", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 143966.1 + ] + }, + "DI0006@5": { + "IO": "DI0006", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC Reserve", + "KENNZEICHNUNG": "=A01+UH05-KF1DI1", + "TEXT-D": "Vorsicherung 400V Reserve", + "TEXT-E": "Pre-fuse 400V Reserve", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 143696.1 + ] + }, + "DI0016@5": { + "IO": "DI0016", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Sicherungsautomatenfall", + "KENNZEICHNUNG": "=A01+UH05-KF1DI1", + "TEXT-D": "Sicherungsautomatenfall", + "TEXT-E": "Circuit breaker case", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 143393.9 + ] + }, + "DI0035@5": { + "IO": "DI0035", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"No fire alarm\"", + "KENNZEICHNUNG": "=A01+UH05-KF1DI2", + "TEXT-D": "IF BST \"No fire alarm\"", + "TEXT-E": "IF BST \"No fire alarm\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 142213.7 + ] + }, + "DI0036@5": { + "IO": "DI0036", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"Non fault\"", + "KENNZEICHNUNG": "=A01+UH05-KF1DI2", + "TEXT-D": "IF BST \"Non fault\"", + "TEXT-E": "IF BST \"Non fault\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 141943.7 + ] + }, + "DI0037@5": { + "IO": "DI0037", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST \"FPC opened\"", + "KENNZEICHNUNG": "=A01+UH05-KF1DI2", + "TEXT-D": "IF BST \"FPC opened\"", + "TEXT-E": "IF BST \"FPC opened\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 141673.7 + ] + }, + "DI0021@5": { + "IO": "DI0021", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC021)", + "KENNZEICHNUNG": "=A01+UH05-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC021)", + "TEXT-E": "Pre-fuse 24V OK (FC021)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 143102.6 + ] + }, + "SF0400@5": { + "IO": "SF0400", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UH05", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 145281.2 + ] + }, + "SF0404@5": { + "IO": "SF0404", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UH05", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 145011.2 + ] + }, + "PF0000@5": { + "IO": "PF0000", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Störung ", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ1", + "TEXT-D": "LM Störung", + "TEXT-E": "IL Trouble", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211691.3, + 146631.2 + ] + }, + "PF0001@5": { + "IO": "PF0001", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LDT Anlage Ein", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211691.3, + 147441.2 + ] + }, + "PF0002@5": { + "IO": "PF0002", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211691.3, + 147171.2 + ] + }, + "PF0003@5": { + "IO": "PF0003", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IL compressed air missing", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211691.3, + 146361.2 + ] + }, + "PF0004@5": { + "IO": "PF0004", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "IL motor protection has tripped", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211691.3, + 146091.2 + ] + }, + "PF0005@5": { + "IO": "PF0005", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "IL fuse has tripped", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211691.3, + 145821.2 + ] + }, + "PF0006@5": { + "IO": "PF0006", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Brandfall", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ1", + "TEXT-D": "LM Brandfall", + "TEXT-E": "IL Brand", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211691.3, + 145551.2 + ] + }, + "PF0031@5": { + "IO": "PF0031", + "ID": "9999", + "VERW": "LED yellow", + "BEZEICHNUNG": "Signalsäule Gelb \" Störung\"", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ2", + "TEXT-D": "Signalsäule Gelb \" Störung\"", + "TEXT-E": "Signal tower yellow\" Trouble \" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 214295.8, + 158365.8 + ] + }, + "PF0030@5": { + "IO": "PF0030", + "ID": "9999", + "VERW": "LED red", + "BEZEICHNUNG": "Signalsäule Rot \" Störung\"", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ2", + "TEXT-D": "Signalsäule Rot \" Not-Halt\"", + "TEXT-E": "Signal tower red\" E-Stop\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 214295.8, + 158095.8 + ] + }, + "PF0032@5": { + "IO": "PF0032", + "ID": "9999", + "VERW": "LED green", + "BEZEICHNUNG": "Signalsäule Grün \" Betriebsbereit\"", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ2", + "TEXT-D": "Signalsäule Grün \" Betriebsbereit\"", + "TEXT-E": "Signal tower green\" System ready\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 214295.8, + 158635.8 + ] + }, + "PF0033@5": { + "IO": "PF0033", + "ID": "9999", + "VERW": "Hupe", + "BEZEICHNUNG": "Signalsäule Hupe \" Anfahrwarnung\"", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ2", + "TEXT-D": "Signalsäule Hupe \" Anfahrwarnung\"", + "TEXT-E": "Signal tower horn\" Restart warning\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 214295.8, + 158905.8 + ] + }, + "FC0064@5": { + "IO": "FC0064", + "ID": "", + "VERW": "MS FC0064", + "BEZEICHNUNG": "MSS ausgelöst FC0064", + "KENNZEICHNUNG": "=A01+UH05-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0064", + "TEXT-E": "MPCB triggered FC0064", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210934.6, + 135197.3 + ] + }, + "SF0041@5": { + "IO": "SF0041", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0501", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 221223.2, + 146655.3 + ] + }, + "SF0401@5": { + "IO": "SF0401", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0501", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 221223.2, + 146355.1 + ] + }, + "SF0405@5": { + "IO": "SF0405", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0501", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 221223.2, + 146085.1 + ] + }, + "PF0041@5": { + "IO": "PF0041", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0501", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 221965.7, + 146655.3 + ] + }, + "PF0040@5": { + "IO": "PF0040", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0501", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 221965.7, + 147195.3 + ] + }, + "SF0055@5": { + "IO": "SF0055", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0507", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 243225.3, + 150080.4 + ] + }, + "SF0473@5": { + "IO": "SF0473", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0507", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 243225.3, + 149780.2 + ] + }, + "SF0477@5": { + "IO": "SF0477", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0507", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 243206.9, + 149524.0 + ] + }, + "PF0055@5": { + "IO": "PF0055", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0507", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 243967.8, + 150080.4 + ] + }, + "PF0054@5": { + "IO": "PF0054", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0507", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 243967.8, + 150620.4 + ] + }, + "FC0063@5": { + "IO": "FC0063", + "ID": "", + "VERW": "MS FC0063", + "BEZEICHNUNG": "MSS ausgelöst FC0063", + "KENNZEICHNUNG": "=A01+UH05-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0063", + "TEXT-E": "MPCB triggered FC0063", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210934.6, + 135467.3 + ] + }, + "FC0061@5": { + "IO": "FC0061", + "ID": "", + "VERW": "MS FC0061", + "BEZEICHNUNG": "MSS ausgelöst FC0061", + "KENNZEICHNUNG": "=A01+UH05-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0061", + "TEXT-E": "MPCB triggered FC0061", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210934.6, + 135993.4 + ] + }, + "FC0060@5": { + "IO": "FC0060", + "ID": "", + "VERW": "MS FC0060", + "BEZEICHNUNG": "MSS ausgelöst FC0060", + "KENNZEICHNUNG": "=A01+UH05-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0060", + "TEXT-E": "MPCB triggered FC0060", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210934.6, + 136263.4 + ] + }, + "FC0065@5": { + "IO": "FC0065", + "ID": "", + "VERW": "MS FC0065", + "BEZEICHNUNG": "MSS ausgelöst FC0065", + "KENNZEICHNUNG": "=A01+UH05-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0065", + "TEXT-E": "MPCB triggered FC0065", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 213544.5, + 136277.3 + ] + }, + "FC0066@5": { + "IO": "FC0066", + "ID": "", + "VERW": "MS FC0066", + "BEZEICHNUNG": "MSS ausgelöst FC0066", + "KENNZEICHNUNG": "=A01+UH05-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0066", + "TEXT-E": "MPCB triggered FC0066", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 213544.5, + 136007.3 + ] + }, + "FC0067@5": { + "IO": "FC0067", + "ID": "", + "VERW": "MS FC0067", + "BEZEICHNUNG": "MSS ausgelöst FC0067", + "KENNZEICHNUNG": "=A01+UH05-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0067", + "TEXT-E": "MPCB triggered FC0067", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 213544.5, + 135737.3 + ] + }, + "FC0070@5": { + "IO": "FC0070", + "ID": "", + "VERW": "MS FC0070", + "BEZEICHNUNG": "MSS ausgelöst FC0070", + "KENNZEICHNUNG": "=A01+UH05-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0070", + "TEXT-E": "MPCB triggered FC0070", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 213544.5, + 135467.3 + ] + }, + "SF0000@4": { + "IO": "SF0000", + "ID": "9999", + "VERW": "PB-BK-NC", + "BEZEICHNUNG": "DT Anlage Aus ", + "KENNZEICHNUNG": "=A01+UH04-KF1DI1", + "TEXT-D": "LDT system On", + "TEXT-E": "PB system On", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 736519.6 + ] + }, + "SF0001@4": { + "IO": "SF0001", + "ID": "9999", + "VERW": "IPB-GN-NO", + "BEZEICHNUNG": "LDT Anlage Ein", + "KENNZEICHNUNG": "=A01+UH04-KF1DI1", + "TEXT-D": "LDT Anlage Ein", + "TEXT-E": "IPB system On", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 736249.6 + ] + }, + "SF0002@4": { + "IO": "SF0002", + "ID": "9999", + "VERW": "IPB-CL-NO", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UH04-KF1DI1", + "TEXT-D": "LDT Start nach Störung", + "TEXT-E": "IPB Start after Trouble", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 735979.6 + ] + }, + "SF0003@4": { + "IO": "SF0003", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "Lampentest", + "KENNZEICHNUNG": "=A01+UH04-KF1DI1", + "TEXT-D": "Lampentest", + "TEXT-E": "Lamp test", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 735709.6 + ] + }, + "DI0005@4": { + "IO": "DI0005", + "ID": "9999", + "VERW": "RELAY-NO", + "BEZEICHNUNG": "Phasenausfall 400V", + "KENNZEICHNUNG": "=A01+UH04-KF1DI1", + "TEXT-D": "Phasenausfall 400V", + "TEXT-E": "Phase failure relay 400V", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 733013.8 + ] + }, + "DI0006@4": { + "IO": "DI0006", + "ID": "9999", + "VERW": "400V-OK", + "BEZEICHNUNG": "Vorsicherung 400V UC Reserve", + "KENNZEICHNUNG": "=A01+UH04-KF1DI1", + "TEXT-D": "Vorsicherung 400V Reserve", + "TEXT-E": "Pre-fuse 400V Reserve", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 732743.8 + ] + }, + "DI0016@4": { + "IO": "DI0016", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Sicherungsautomatenfall", + "KENNZEICHNUNG": "=A01+UH04-KF1DI1", + "TEXT-D": "Sicherungsautomatenfall", + "TEXT-E": "Circuit breaker case", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 732433.7 + ] + }, + "FC0062@4": { + "IO": "FC0062", + "ID": "", + "VERW": "MS FC0062", + "BEZEICHNUNG": "MSS ausgelöst FC0062", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0062", + "TEXT-E": "MPC triggered FC0062", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361252.4, + 724976.5 + ] + }, + "FC0070@4": { + "IO": "FC0070", + "ID": "", + "VERW": "MS FC0070", + "BEZEICHNUNG": "MSS ausgelöst FC0070", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS hat ausgelöst FC0070", + "TEXT-E": "MPC triggered FC0070", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 363741.6, + 725506.6 + ] + }, + "FC0072@4": { + "IO": "FC0072", + "ID": "", + "VERW": "MS FC0072", + "BEZEICHNUNG": "MSS ausgelöst FC0072", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0072", + "TEXT-E": "MPC triggered FC0072", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 363727.9, + 724976.5 + ] + }, + "FC0060@4": { + "IO": "FC0060", + "ID": "", + "VERW": "MS FC0060", + "BEZEICHNUNG": "MSS ausgelöst FC0060", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "", + "TEXT-E": "MPC triggered FC0060", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361252.4, + 725516.5 + ] + }, + "FC0063@4": { + "IO": "FC0063", + "ID": "", + "VERW": "MS FC0063", + "BEZEICHNUNG": "MSS ausgelöst FC0063", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0063", + "TEXT-E": "MPC triggered FC0063", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361252.4, + 724706.5 + ] + }, + "FC0065@4": { + "IO": "FC0065", + "ID": "", + "VERW": "MS FC0065", + "BEZEICHNUNG": "MSS ausgelöst FC0065", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0065", + "TEXT-E": "MPC triggered FC0065", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361252.4, + 724166.5 + ] + }, + "FC0064@4": { + "IO": "FC0064", + "ID": "", + "VERW": "MS FC0064", + "BEZEICHNUNG": "MSS ausgelöst FC0064", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0064", + "TEXT-E": "MPC triggered FC0064", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361252.4, + 724436.5 + ] + }, + "FC0066@4": { + "IO": "FC0066", + "ID": "", + "VERW": "MS FC0066", + "BEZEICHNUNG": "MSS ausgelöst FC0066", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0066", + "TEXT-E": "MPC triggered FC0066", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361261.4, + 723906.3 + ] + }, + "FC0073@4": { + "IO": "FC0073", + "ID": "", + "VERW": "MS FC0073", + "BEZEICHNUNG": "MSS ausgelöst FC0073", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0073", + "TEXT-E": "MPC triggered FC0073", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 363727.9, + 724706.5 + ] + }, + "FC0074@4": { + "IO": "FC0074", + "ID": "", + "VERW": "MS FC0074", + "BEZEICHNUNG": "MSS ausgelöst FC0074", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0074", + "TEXT-E": "MPC triggered FC0074", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 363727.9, + 724436.5 + ] + }, + "SF0471@4": { + "IO": "SF0471", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0x)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDI7", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0x)", + "TEXT-E": "E-stop interace CH1 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361274.3, + 728083.1 + ] + }, + "SF0472@4": { + "IO": "SF0472", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0x)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDI7", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0x)", + "TEXT-E": "E-stop interace CH2 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361274.3, + 727813.1 + ] + }, + "SF0475@4": { + "IO": "SF0475", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0x)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDI7", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0x)", + "TEXT-E": "E-stop interace CH1 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361274.3, + 726559.6 + ] + }, + "SF0476@4": { + "IO": "SF0476", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (Reserve)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDI7", + "TEXT-D": "Not Halt Schnittstelle CH2 (Reserve)", + "TEXT-E": "E-stop interace CH2 (Reserve) ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361274.3, + 726289.6 + ] + }, + "DI0021@4": { + "IO": "DI0021", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC021)", + "KENNZEICHNUNG": "=A01+UH04-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC021)", + "TEXT-E": "Pre-fuse 24V OK (FC021)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 732142.4 + ] + }, + "SF0400@4": { + "IO": "SF0400", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UH04", + "KENNZEICHNUNG": "=A01+UH04-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 734089.6 + ] + }, + "SF0404@4": { + "IO": "SF0404", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 2 UH04", + "KENNZEICHNUNG": "=A01+UH04-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 733819.6 + ] + }, + "FC0061@4": { + "IO": "FC0061", + "ID": "", + "VERW": "MS FC0061", + "BEZEICHNUNG": "MSS ausgelöst FC0061", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0061", + "TEXT-E": "MPC triggered FC0061", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361252.4, + 725260.3 + ] + }, + "PF0000@4": { + "IO": "PF0000", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Störung ", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ1", + "TEXT-D": "LM Störung ", + "TEXT-E": "IL Trouble", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362013.3, + 735439.6 + ] + }, + "PF0001@4": { + "IO": "PF0001", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LDT Anlage Ein", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362013.3, + 736249.6 + ] + }, + "PF0002@4": { + "IO": "PF0002", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LDT Start nach Störung", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ1", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362013.3, + 735979.6 + ] + }, + "PF0003@4": { + "IO": "PF0003", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Druckluft fehlt", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ1", + "TEXT-D": "LM Druckluft fehlt", + "TEXT-E": "IL compressed air missing", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362013.3, + 735169.6 + ] + }, + "PF0004@4": { + "IO": "PF0004", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Motorschutz hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ1", + "TEXT-D": "LM Motorschutz hat ausgelöst", + "TEXT-E": "LM motor protection has tripped", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362013.3, + 734899.6 + ] + }, + "PF0005@4": { + "IO": "PF0005", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Sicherung hat ausgelöst", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ1", + "TEXT-D": "LM Sicherung hat ausgelöst", + "TEXT-E": "LM fuse has tripped", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362013.3, + 734629.6 + ] + }, + "PF0006@4": { + "IO": "PF0006", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Brandfall", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ1", + "TEXT-D": "LM Brandfall", + "TEXT-E": "LM Brand", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362013.3, + 734359.6 + ] + }, + "PF0031@4": { + "IO": "PF0031", + "ID": "9999", + "VERW": "LED yellow", + "BEZEICHNUNG": "Signalsäule Gelb \" Störung\"", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ2", + "TEXT-D": "Signalsäule Gelb \" Störung\"", + "TEXT-E": "Signal tower yellow\" Trouble \" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362354.1, + 738840.7 + ] + }, + "PF0030@4": { + "IO": "PF0030", + "ID": "9999", + "VERW": "LED red", + "BEZEICHNUNG": "Signalsäule Rot \" Störung\"", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ2", + "TEXT-D": "Signalsäule Rot \" Not-Halt\"", + "TEXT-E": "Signal tower red\" E-Stop\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362354.1, + 738570.7 + ] + }, + "PF0032@4": { + "IO": "PF0032", + "ID": "9999", + "VERW": "LED green", + "BEZEICHNUNG": "Signalsäule Grün \" Betriebsbereit\"", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ2", + "TEXT-D": "Signalsäule Grün \" Betriebsbereit\"", + "TEXT-E": "Signal tower green\" System ready\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362354.1, + 739110.7 + ] + }, + "PF0033@4": { + "IO": "PF0033", + "ID": "9999", + "VERW": "Hupe", + "BEZEICHNUNG": "Signalsäule Hupe \" Anfahrwarnung\"", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ2", + "TEXT-D": "Signalsäule Hupe \" Anfahrwarnung\"", + "TEXT-E": "Signal tower horn\" Restart warning\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362354.1, + 739380.7 + ] + }, + "UC0404": { + "A": "0", + "B": "UC0404", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 351508.0, + 750926.0 + ] + }, + "UC0403": { + "A": "0", + "B": "UC0403", + "C": "86613113910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 100SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 351439.7, + 741406.5 + ] + }, + "FC0071@4": { + "IO": "FC0071", + "ID": "", + "VERW": "MS FC0071", + "BEZEICHNUNG": "MSS ausgelöst FC0071", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0071", + "TEXT-E": "MPC triggered FC0071", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 363727.9, + 725246.5 + ] + }, + "SF0055@4": { + "IO": "SF0055", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0402", + "KENNZEICHNUNG": "=A01+UH04-KF1DI3", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 344423.5, + 742832.4 + ] + }, + "SF0057@4": { + "IO": "SF0057", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0401", + "KENNZEICHNUNG": "=A01+UH04-KF1DI3", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 344424.9, + 751286.6 + ] + }, + "SF0053@4": { + "IO": "SF0053", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0403", + "KENNZEICHNUNG": "=A01+UH04-KF1DI3", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 344394.8, + 730569.8 + ] + }, + "SF0025@4": { + "IO": "SF0025", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "MT freigeben UZ0403, Workstation MPS 3", + "KENNZEICHNUNG": "=A01+UH04-KF1DI2", + "TEXT-D": "Freigabe", + "TEXT-E": "Release", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 344394.8, + 730311.0 + ] + }, + "SF0027@4": { + "IO": "SF0027", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "MT freigeben UZ0401, Workstation MPS 1", + "KENNZEICHNUNG": "=A01+UH04-KF1DI2", + "TEXT-D": "Freigabe ", + "TEXT-E": "Release", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 344424.9, + 751027.7 + ] + }, + "SF0026@4": { + "IO": "SF0026", + "ID": "9999", + "VERW": "PB-WH-NO", + "BEZEICHNUNG": "MT freigeben UZ0402, Workstation MPS 2", + "KENNZEICHNUNG": "=A01+UH04-KF1DI2", + "TEXT-D": "Freigabe", + "TEXT-E": "Release", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 344423.5, + 742573.6 + ] + }, + "SF0051@4": { + "IO": "SF0051", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0409", + "KENNZEICHNUNG": "=A01+UH04-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 371958.7, + 753262.5 + ] + }, + "SF0473@4": { + "IO": "SF0473", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0409", + "KENNZEICHNUNG": "=A01+UH04-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 371958.7, + 752962.2 + ] + }, + "SF0477@4": { + "IO": "SF0477", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0409", + "KENNZEICHNUNG": "=A01+UH04-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 371958.7, + 752692.2 + ] + }, + "PF0055@4": { + "IO": "PF0055", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0402", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ06", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 345166.0, + 742832.4 + ] + }, + "PF0054@4": { + "IO": "PF0054", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0402", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ06", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 345166.0, + 743372.4 + ] + }, + "PF0057@4": { + "IO": "PF0057", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0401", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ06", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 345167.4, + 751283.9 + ] + }, + "PF0056@4": { + "IO": "PF0056", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0401", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ06", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 345167.4, + 751822.7 + ] + }, + "PF0053@4": { + "IO": "PF0053", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0403", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ06", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 345137.3, + 730569.8 + ] + }, + "PF0052@4": { + "IO": "PF0052", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0403", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ06", + "TEXT-D": "Betriebsbereit ", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 345137.3, + 731109.8 + ] + }, + "PF0051@4": { + "IO": "PF0051", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0409", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 372701.2, + 753262.5 + ] + }, + "PF0050@4": { + "IO": "PF0050", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0409", + "KENNZEICHNUNG": "=A01+UH04-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 372701.2, + 753802.5 + ] + }, + "DI0035@4": { + "IO": "DI0035", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST 4 \"No fire alarm\"", + "KENNZEICHNUNG": "=A01+UH04-KF1DI2", + "TEXT-D": "IF BST 4 \"No fire alarm\"", + "TEXT-E": "IF FD 4 \"No fire alarm\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361277.5, + 731243.1 + ] + }, + "DI0036@4": { + "IO": "DI0036", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST 4 \"Non fault\"", + "KENNZEICHNUNG": "=A01+UH04-KF1DI2", + "TEXT-D": "IF BST 4 \"Non fault\"", + "TEXT-E": "IF FD 4 \"Non fault\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361277.5, + 730973.1 + ] + }, + "DI0037@4": { + "IO": "DI0037", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "IF BST 4 \"FPC opened\"", + "KENNZEICHNUNG": "=A01+UH04-KF1DI2", + "TEXT-D": "IF BST 4 \"FPC opened\"", + "TEXT-E": "IF FD 4 \"FPC opened\"", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361277.5, + 730703.1 + ] + }, + "DI0022@4": { + "IO": "DI0022", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC022)", + "KENNZEICHNUNG": "=A01+UH04-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC022)", + "TEXT-E": "Pre-fuse 24V OK (FC022)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 731872.4 + ] + }, + "DI0023@4": { + "IO": "DI0023", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC023)", + "KENNZEICHNUNG": "=A01+UH04-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC023)", + "TEXT-E": "Pre-fuse 24V OK (FC023)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361270.8, + 731602.4 + ] + }, + "SF0470@1": { + "IO": "SF0470", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 LS 2 UZ0104", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 336301.7, + 149139.4 + ] + }, + "SF0031@1": { + "IO": "SF0031", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0101", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 335107.8, + 169990.9 + ] + }, + "SF0401@1": { + "IO": "SF0401", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0101", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI5", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 335107.8, + 169667.1 + ] + }, + "SF0405@1": { + "IO": "SF0405", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0101", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI5", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 335107.8, + 169397.1 + ] + }, + "SF0041@1": { + "IO": "SF0041", + "ID": "9999", + "VERW": "KN-0-1", + "BEZEICHNUNG": "Strahler ein/aus LS1", + "KENNZEICHNUNG": "=A01+UH01-KF1DI3", + "TEXT-D": "Strahler ein/aus LS1", + "TEXT-E": "light on/off LB1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 333191.0, + 150479.2 + ] + }, + "SF0403@1": { + "IO": "SF0403", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 LS 1 UZ0103", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI5", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 333199.4, + 149118.3 + ] + }, + "SF0043@1": { + "IO": "SF0043", + "ID": "9999", + "VERW": "LDT-BU-NO", + "BEZEICHNUNG": "Reset LS1", + "KENNZEICHNUNG": "=A01+UH01-KF1DI3", + "TEXT-D": "Reset LS1", + "TEXT-E": "Reset LB1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 333191.0, + 149500.4 + ] + }, + "SF0032@1": { + "IO": "SF0032", + "ID": "9999", + "VERW": "IPB-CL-NO", + "BEZEICHNUNG": "Freigabe UZ0102", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "Freigabe", + "TEXT-E": "Release", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 324061.5, + 151394.7 + ] + }, + "SF0033@1": { + "IO": "SF0033", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0102", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "Reset ", + "TEXT-E": "Reset ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 324061.5, + 151124.7 + ] + }, + "SF0402@1": { + "IO": "SF0402", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0102", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI5", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 324061.5, + 150800.9 + ] + }, + "SF0406@1": { + "IO": "SF0406", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0102", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI5", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 324061.5, + 150530.9 + ] + }, + "SF0044@1": { + "IO": "SF0044", + "ID": "9999", + "VERW": "IPB-GN-NO", + "BEZEICHNUNG": "Ladebaum aktivieren LS1", + "KENNZEICHNUNG": "=A01+UH01-KF1DI3", + "TEXT-D": "Ladebaum aktivieren LS1", + "TEXT-E": "Loading boom activaded LB1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 333191.0, + 149840.4 + ] + }, + "UC0102": { + "A": "0", + "B": "UC0102", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335470.6, + 152241.2 + ] + }, + "UC0101": { + "A": "0", + "B": "UC0101", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335577.5, + 165776.0 + ] + }, + "UC0111": { + "A": "0", + "B": "UC0111", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 338304.8, + 167295.4 + ] + }, + "PF0030@1": { + "IO": "PF0030", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0101", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 335851.2, + 170521.2 + ] + }, + "PF0031@1": { + "IO": "PF0031", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0101", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 335851.2, + 169990.9 + ] + }, + "PF0040@1": { + "IO": "PF0040", + "ID": "9999", + "VERW": "LM-GN-LED", + "BEZEICHNUNG": "Betriebsbereit LS1", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ3", + "TEXT-D": "Betriebsbereit LS1", + "TEXT-E": "Ready for use LB1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 333933.5, + 150749.2 + ] + }, + "PF0034@1": { + "IO": "PF0034", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0102", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ2", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 324804.0, + 151664.7 + ] + }, + "PF0033@1": { + "IO": "PF0033", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset UZ0102", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 324804.0, + 151124.7 + ] + }, + "PF0043@1": { + "IO": "PF0043", + "ID": "9999", + "VERW": "IPB-BU-LED", + "BEZEICHNUNG": "Reset LS1", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 333933.5, + 149500.4 + ] + }, + "SF0407@1": { + "IO": "SF0407", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 LS 1 UZ0103", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI5", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-Stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 333199.4, + 148848.3 + ] + }, + "SF0474@1": { + "IO": "SF0474", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 LS 2 UZ0104", + "KENNZEICHNUNG": "=A01+UH01-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-Stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 336301.7, + 148869.4 + ] + }, + "SF0046@1": { + "IO": "SF0046", + "ID": "9999", + "VERW": "KN-0-1", + "BEZEICHNUNG": "Strahler ein/aus LS2", + "KENNZEICHNUNG": "=A01+UH01-KF1DI3", + "TEXT-D": "Strahler ein/aus LS2", + "TEXT-E": "light on/off LB2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 336293.3, + 150479.2 + ] + }, + "SF0054@1": { + "IO": "SF0054", + "ID": "9999", + "VERW": "LDT-BU-NO", + "BEZEICHNUNG": "Reset LS2", + "KENNZEICHNUNG": "=A01+UH01-KF1DI3", + "TEXT-D": "Reset LS2", + "TEXT-E": "Reset LS2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 336293.3, + 149500.4 + ] + }, + "SF0055@1": { + "IO": "SF0055", + "ID": "9999", + "VERW": "IPB-GN-NO", + "BEZEICHNUNG": "Ladebaum aktivieren LS2", + "KENNZEICHNUNG": "=A01+UH01-KF1DI3", + "TEXT-D": "Ladebaum aktivieren LS2", + "TEXT-E": "Loading boom activaded LB2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 336293.3, + 149840.4 + ] + }, + "PF0045@1": { + "IO": "PF0045", + "ID": "9999", + "VERW": "LM-GN-LED", + "BEZEICHNUNG": "Betriebsbereit LS2", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ3", + "TEXT-D": "Betriebsbereit LS2", + "TEXT-E": "Ready for use LB2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 337035.8, + 150749.2 + ] + }, + "PF0054@1": { + "IO": "PF0054", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset LS2", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 337035.8, + 149500.4 + ] + }, + "PF0032@1": { + "IO": "PF0032", + "ID": "9999", + "VERW": "IPB-CL-LED", + "BEZEICHNUNG": "Reset UZ0102", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ2", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 324804.0, + 151394.7 + ] + }, + "PF0044@1": { + "IO": "PF0044", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "LED Ladebaum aktiv", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 333933.5, + 149840.4 + ] + }, + "PF0055@1": { + "IO": "PF0055", + "ID": "9999", + "VERW": "IPB-GN-LED", + "BEZEICHNUNG": "LED Ladebaum 2 aktiv", + "KENNZEICHNUNG": "=A01+UH01-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 337035.8, + 149840.4 + ] + }, + "SF1470@3": { + "IO": "SF1470", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0305", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI4", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 183867.3, + 438954.4 + ] + }, + "SF1474@3": { + "IO": "SF1474", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0305", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI4", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 183867.3, + 438684.4 + ] + }, + "SF1471@3": { + "IO": "SF1471", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0306", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI4", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 199696.5, + 438896.9 + ] + }, + "SF1475@3": { + "IO": "SF1475", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0306", + "KENNZEICHNUNG": "=A01+UC032-KF1FDI3", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 199696.5, + 438626.9 + ] + }, + "SF1472@3": { + "IO": "SF1472", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0307", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI4", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 217447.0, + 438874.8 + ] + }, + "SF1476@3": { + "IO": "SF1476", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0307", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI4", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 217447.0, + 438604.8 + ] + }, + "SF1473@3": { + "IO": "SF1473", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0308", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI4", + "TEXT-D": "NA Kanal 1", + "TEXT-E": "E-stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 234637.1, + 438406.0 + ] + }, + "SF1477@3": { + "IO": "SF1477", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0308", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI4", + "TEXT-D": "NA Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 234637.1, + 438136.0 + ] + }, + "DI0022@5": { + "IO": "DI0022", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC022)", + "KENNZEICHNUNG": "=A01+UH05-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC022)", + "TEXT-E": "Pre-fuse 24V OK (FC022)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 142832.6 + ] + }, + "DI0023@5": { + "IO": "DI0023", + "ID": "9999", + "VERW": "24V-OK", + "BEZEICHNUNG": "Vorsicherung 24V OK (FC023)", + "KENNZEICHNUNG": "=A01+UH05-KF1DI2", + "TEXT-D": "Vorsicherung 24V OK (FC023)", + "TEXT-E": "Pre-fuse 24V OK (FC023)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 142562.6 + ] + }, + "UH02": { + "A": "0", + "B": "UH02", + "C": "86623213910015374844", + "ARTINR": "790821106", + "BESCHR": "SCHALTSCHRANK 800X2000X400, 1-TÜRIG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 251117.3, + 289859.0 + ] + }, + "UH03": { + "A": "0", + "B": "UH03", + "C": "86623213910015374844", + "ARTINR": "790821106", + "BESCHR": "SCHALTSCHRANK 800X2000X400, 1-TÜRIG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 202828.6, + 439809.7 + ] + }, + "UH05": { + "A": "0", + "B": "UH05", + "C": "86623213910015374844", + "ARTINR": "790820400", + "BESCHR": "SCHALTSCHRANK 800X2000X400, 1-TÜRIG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 216411.8, + 155297.9 + ] + }, + "UC023": { + "A": "0", + "B": "UC023", + "C": "86623213910015374844", + "ARTINR": "790820400", + "BESCHR": "SCHALTSCHRANK 800X2000X400, 1-TÜRIG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 246097.6, + 247241.0 + ] + }, + "UC022": { + "A": "0", + "B": "UC022", + "C": "86623213910015374844", + "ARTINR": "790820400", + "BESCHR": "SCHALTSCHRANK 800X2000X400, 1-TÜRIG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 251089.8, + 269686.6 + ] + }, + "UC033": { + "A": "0", + "B": "UC033", + "C": "86623213910015374844", + "ARTINR": "790820400", + "BESCHR": "SCHALTSCHRANK 800X2000X400, 1-TÜRIG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204161.6, + 397358.6 + ] + }, + "UC031": { + "A": "0", + "B": "UC031", + "C": "86623213910015374844", + "ARTINR": "790820400", + "BESCHR": "SCHALTSCHRANK 800X2000X400, 1-TÜRIG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 204170.7, + 460806.7 + ] + }, + "UC032": { + "A": "0", + "B": "UC032", + "C": "86623213910015374844", + "ARTINR": "790820400", + "BESCHR": "SCHALTSCHRANK 800X2000X400, 1-TÜRIG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 214820.0, + 419681.4 + ] + }, + "UC061": { + "A": "0", + "B": "UC061", + "C": "86623213910015374844", + "ARTINR": "790820400", + "BESCHR": "SCHALTSCHRANK 800X2000X400, 1-TÜRIG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 335696.9, + 444980.9 + ] + }, + "UC011": { + "A": "0", + "B": "UC011", + "C": "86623213910015374844", + "ARTINR": "790820400", + "BESCHR": "SCHALTSCHRANK 800X2000X400, 1-TÜRIG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 334754.1, + 449067.7 + ] + }, + "UH01": { + "A": "0", + "B": "UH01", + "C": "86623213910015374844", + "ARTINR": "790821106", + "BESCHR": "SCHALTSCHRANK 800X2000X400, 1-TÜRIG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 329543.9, + 150184.6 + ] + }, + "PF0000@3": { + "IO": "PF0000", + "ID": "9999", + "VERW": "IL-YE-LED", + "BEZEICHNUNG": "LM Störung ", + "KENNZEICHNUNG": "=A01+UH03-KF1DQ1", + "TEXT-D": "LM Störung", + "TEXT-E": "IL Trouble", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253536.1, + 441348.2 + ] + }, + "PF3311@4": { + "IO": "PF3311", + "ID": "9999", + "VERW": "LED yellow", + "BEZEICHNUNG": " \"call for help\" MPS 3 Signalsäule gelb", + "KENNZEICHNUNG": "=A01+UC0402-KF1DQ1", + "TEXT-D": "call for help", + "TEXT-E": "call for help", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 350484.1, + 729207.7 + ] + }, + "PF3371@4": { + "IO": "PF3371", + "ID": "9999", + "VERW": "LED yellow", + "BEZEICHNUNG": "calll for help", + "KENNZEICHNUNG": "=A01+UC0403-KF1DQ1", + "TEXT-D": "call for help", + "TEXT-E": "call for help", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 350484.1, + 741237.7 + ] + }, + "PF3431@4": { + "IO": "PF3431", + "ID": "9999", + "VERW": "LED yellow", + "BEZEICHNUNG": "calll for help", + "KENNZEICHNUNG": "=A01+UC0404-KF1DQ1", + "TEXT-D": "call for help", + "TEXT-E": "call for help", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 350484.1, + 750737.7 + ] + }, + "DI0034@2": { + "IO": "DI0034", + "ID": "9999", + "VERW": "IF FACP fire alarm ", + "BEZEICHNUNG": "IF BMZ \"fire alarm\" ", + "KENNZEICHNUNG": "=A01+UH02-KF1DI2", + "TEXT-D": "IF BMZ \"fire alarm\" ", + "TEXT-E": "IF from FACP \"fire alarm\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "2", + "pos": [ + 252901.1, + 272710.4 + ] + }, + "DI0034@3": { + "IO": "DI0034", + "ID": "9999", + "VERW": "IF FACP fire alarm ", + "BEZEICHNUNG": "IF BMZ \"fire alarm\" ", + "KENNZEICHNUNG": "=A01+UH03-KF1DI2", + "TEXT-D": "IF BMZ \"fire alarm\" ", + "TEXT-E": "IF from FACP \"fire alarm\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252901.1, + 425990.4 + ] + }, + "DI0034@7": { + "IO": "DI0034", + "ID": "9999", + "VERW": "IF FACP fire alarm ", + "BEZEICHNUNG": "IF BMZ \"fire alarm\" ", + "KENNZEICHNUNG": "=A01+UH04-KF1DI2", + "TEXT-D": "IF BMZ \"fire alarm\" ", + "TEXT-E": "IF from FACP \"fire alarm\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "7", + "pos": [ + 361378.3, + 722948.6 + ] + }, + "DI0034@5": { + "IO": "DI0034", + "ID": "9999", + "VERW": "IF FACP fire alarm ", + "BEZEICHNUNG": "IF BMZ \"fire alarm\" ", + "KENNZEICHNUNG": "=A01+UH05-KF1DI2", + "TEXT-D": "IF BMZ \"fire alarm\" ", + "TEXT-E": "IF from FACP \"fire alarm\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211056.3, + 134221.7 + ] + }, + "DI0034@1": { + "IO": "DI0034", + "ID": "9999", + "VERW": "IF FACP fire alarm ", + "BEZEICHNUNG": "IF BMZ \"fire alarm\" ", + "KENNZEICHNUNG": "=A01+UH01-KF1DI2", + "TEXT-D": "IF BMZ \"fire alarm\" ", + "TEXT-E": "IF from FACP \"fire alarm\" ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328024.6, + 130120.5 + ] + }, + "UC2101": { + "A": "0", + "B": "UC2101", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179360.1, + 310441.7 + ] + }, + "UC2102": { + "A": "0", + "B": "UC2102", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 197414.5, + 310396.1 + ] + }, + "UC2103": { + "A": "0", + "B": "UC2103", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215268.4, + 310007.0 + ] + }, + "UC2104": { + "A": "0", + "B": "UC2104", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BX", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232687.6, + 310411.3 + ] + }, + "UC3102": { + "A": "0", + "B": "UC3102", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 198115.0, + 460528.7 + ] + }, + "UC3103": { + "A": "0", + "B": "UC3103", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215396.1, + 460497.3 + ] + }, + "UC3104": { + "A": "0", + "B": "UC3104", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232678.6, + 460538.6 + ] + }, + "UC3302": { + "A": "0", + "B": "UC3302", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 198103.0, + 397612.9 + ] + }, + "UC3303": { + "A": "0", + "B": "UC3303", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 215381.8, + 397635.9 + ] + }, + "UC3304": { + "A": "0", + "B": "UC3304", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 232668.2, + 397631.2 + ] + }, + "UC3301": { + "A": "0", + "B": "UC3301", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179335.2, + 397598.0 + ] + }, + "UC3101": { + "A": "0", + "B": "UC3101", + "C": "86623213910015374844", + "ARTINR": "790801501", + "BESCHR": "Busverteiler kpl. ET 200SP DI+DQ, Exact -BG", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 179334.2, + 460534.2 + ] + }, + "SF0042@5": { + "IO": "SF0042", + "ID": "9999", + "VERW": "PB-WT-NO", + "BEZEICHNUNG": "Freigabe UZ0502", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Freigabe", + "TEXT-E": "Release", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 217133.1, + 159214.3 + ] + }, + "SF0043@5": { + "IO": "SF0043", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0502", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 217133.1, + 158944.3 + ] + }, + "SF0402@5": { + "IO": "SF0402", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0502", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 217133.1, + 158644.1 + ] + }, + "SF0406@5": { + "IO": "SF0406", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0502", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 217133.1, + 158374.1 + ] + }, + "PF0043@5": { + "IO": "PF0043", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0502", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 217875.6, + 158944.3 + ] + }, + "PF0042@5": { + "IO": "PF0042", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0502", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 217875.6, + 159484.3 + ] + }, + "SF0044@5": { + "IO": "SF0044", + "ID": "9999", + "VERW": "PB-WT-NO", + "BEZEICHNUNG": "Freigabe UZ0503", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Freigabe", + "TEXT-E": "Release", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 222084.6, + 159218.4 + ] + }, + "SF0045@5": { + "IO": "SF0045", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0503", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 222084.6, + 158948.4 + ] + }, + "SF0403@5": { + "IO": "SF0403", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0503", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 222084.6, + 158648.2 + ] + }, + "SF0407@5": { + "IO": "SF0407", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0503", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI6", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 222084.6, + 158378.2 + ] + }, + "PF0045@5": { + "IO": "PF0045", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0503", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 222827.1, + 158948.4 + ] + }, + "PF0044@5": { + "IO": "PF0044", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0503", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 222827.1, + 159488.4 + ] + }, + "SF0046@5": { + "IO": "SF0046", + "ID": "9999", + "VERW": "IPB-YE-NO", + "BEZEICHNUNG": "Bereichshalt UZ0504", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Bereichshalt", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 226082.6, + 159218.6 + ] + }, + "SF0047@5": { + "IO": "SF0047", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0504", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 226082.6, + 158948.6 + ] + }, + "SF0470@5": { + "IO": "SF0470", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0504", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 226082.6, + 158648.4 + ] + }, + "SF0474@5": { + "IO": "SF0474", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0504", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 226082.6, + 158378.4 + ] + }, + "PF0047@5": { + "IO": "PF0047", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0504", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 226825.1, + 158948.6 + ] + }, + "PF0046@5": { + "IO": "PF0046", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0504", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 226825.1, + 159488.6 + ] + }, + "SF0050@5": { + "IO": "SF0050", + "ID": "9999", + "VERW": "PB-WT-NO", + "BEZEICHNUNG": "Freigabe UZ0505", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Freigabe", + "TEXT-E": "Area stop", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 229964.3, + 159213.0 + ] + }, + "SF0051@5": { + "IO": "SF0051", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0505", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 229964.3, + 158943.0 + ] + }, + "SF0471@5": { + "IO": "SF0471", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0505", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 229964.3, + 158642.8 + ] + }, + "SF0475@5": { + "IO": "SF0475", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0505", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 229964.3, + 158372.8 + ] + }, + "PF0051@5": { + "IO": "PF0051", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0505", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 230706.8, + 158943.0 + ] + }, + "PF0050@5": { + "IO": "PF0050", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0505", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 230706.8, + 159483.0 + ] + }, + "SF0052@5": { + "IO": "SF0052", + "ID": "9999", + "VERW": "PB-WT-NO", + "BEZEICHNUNG": "Freigeben UZ0506", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Freigeben", + "TEXT-E": "Release", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 235226.2, + 159219.1 + ] + }, + "SF0053@5": { + "IO": "SF0053", + "ID": "9999", + "VERW": "IPB-BU-NO", + "BEZEICHNUNG": "Reset UZ0506", + "KENNZEICHNUNG": "=A01+UH05-KF1DI3", + "TEXT-D": "Reset", + "TEXT-E": "Reset", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 235226.2, + 158949.1 + ] + }, + "SF0472@5": { + "IO": "SF0472", + "ID": "9999", + "VERW": "PDT-NC-1", + "BEZEICHNUNG": "Not Halt Kanal 1 UZ0506", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 1", + "TEXT-E": "E-Stop Canal 1", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 235226.2, + 158648.9 + ] + }, + "SF0476@5": { + "IO": "SF0476", + "ID": "9999", + "VERW": "PDT-NC-2", + "BEZEICHNUNG": "Not Halt Kanal 2 UZ0506", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not-Halt Kanal 2", + "TEXT-E": "E-stop Canal 2", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 235226.2, + 158378.9 + ] + }, + "PF0053@5": { + "IO": "PF0053", + "ID": "9999", + "VERW": "IPB-YE-LED", + "BEZEICHNUNG": "Reset UZ0506", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 235968.7, + 158949.1 + ] + }, + "PF0052@5": { + "IO": "PF0052", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Betriebsbereit UZ0506", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ3", + "TEXT-D": "Betriebsbereit", + "TEXT-E": "Ready for use", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 235968.7, + 159489.1 + ] + }, + "PF0073@5": { + "IO": "PF0073", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Release UZ0502", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 217875.6, + 159214.3 + ] + }, + "PF0074@5": { + "IO": "PF0074", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Release UZ0503", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 222827.1, + 159214.3 + ] + }, + "PF0075@5": { + "IO": "PF0075", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Release UZ0504", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 226825.1, + 159214.3 + ] + }, + "PF0076@5": { + "IO": "PF0076", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Release UZ0505", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 230706.8, + 159213.0 + ] + }, + "PF0077@5": { + "IO": "PF0077", + "ID": "9999", + "VERW": "IPB-BN-LED", + "BEZEICHNUNG": "Release UZ0506", + "KENNZEICHNUNG": "=A01+UH05-KF1DQ4", + "TEXT-D": "", + "TEXT-E": "", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 235968.7, + 159219.1 + ] + }, + "DI0106@3": { + "IO": "DI0106", + "ID": "9999", + "VERW": "NC", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv (QA0920/QA0921)", + "KENNZEICHNUNG": "=A01+UC031-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv (QA0920/QA0921)", + "TEXT-E": "Feedback 400V Main relay activ (QA0920/QA0921)", + "TEXT-ES": "", + "TEXT-F": "Feedback Hauptschütze aktiv", + "SPS": "3", + "pos": [ + 252828.8, + 459129.3 + ] + }, + "DI0114@3": { + "IO": "DI0114", + "ID": "9999", + "VERW": "NC", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA0922/QA0923)", + "KENNZEICHNUNG": "=A01+UC031-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA0922/QA0923)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0922/QA0923)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252828.8, + 458249.3 + ] + }, + "SF0781@3": { + "IO": "SF0781", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0X)", + "TEXT-E": "E-stop interace CH1 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252828.8, + 457669.5 + ] + }, + "SF0785@3": { + "IO": "SF0785", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC031-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0X)", + "TEXT-E": "E-stop interace CH2 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252828.8, + 457399.5 + ] + }, + "QA0920@3": { + "IO": "QA0920", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0140/QA0145)", + "KENNZEICHNUNG": "=A01+UC031-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0140/QA0145)", + "TEXT-E": "Main contactor activate CH 1 (QA0140/QA0145)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253562.3, + 459399.3 + ] + }, + "QA0921@3": { + "IO": "QA0921", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0140/QA0145)", + "KENNZEICHNUNG": "=A01+UC031-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0140/QA0145)", + "TEXT-E": "Main contactor activate CH 2 (QA0140/QA0145)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253571.3, + 458859.3 + ] + }, + "QA0922@3": { + "IO": "QA0922", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC031-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (zu UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253571.3, + 458519.3 + ] + }, + "QA0923@3": { + "IO": "QA0923", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC031-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (zu UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253571.3, + 457979.3 + ] + }, + "QA1540@3": { + "IO": "QA1540", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0260/QA0265)", + "KENNZEICHNUNG": "=A01+UC033-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0260/QA0265)", + "TEXT-E": "Main contactor activate CH 1 (QA0260/QA0265)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253434.9, + 401260.1 + ] + }, + "QA1541@3": { + "IO": "QA1541", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0260/QA0265)", + "KENNZEICHNUNG": "=A01+UC033-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0260/QA0265)", + "TEXT-E": "Main contactor activate CH 2 (QA0260/QA0265)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253469.2, + 400719.0 + ] + }, + "QA1542@3": { + "IO": "QA1542", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC033-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (zu UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253434.9, + 400371.0 + ] + }, + "QA1543@3": { + "IO": "QA1543", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC033-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (zu UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253434.9, + 399831.0 + ] + }, + "SF1401@3": { + "IO": "SF1401", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC033-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0X)", + "TEXT-E": "E-stop interace CH1 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 399528.9 + ] + }, + "SF1405@3": { + "IO": "SF1405", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC033-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0X)", + "TEXT-E": "E-stop interace CH2 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 399258.9 + ] + }, + "FC0145@1": { + "IO": "FC0145", + "ID": "", + "VERW": "MS FC0145", + "BEZEICHNUNG": "MSS ausgelöst FC0145 (CV-M4104)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0145", + "TEXT-E": "MPCB triggered FC0145", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329374.5, + 452150.1 + ] + }, + "FC0152@1": { + "IO": "FC0152", + "ID": "", + "VERW": "MS FC0152", + "BEZEICHNUNG": "MSS ausgelöst FC0152 (Reserve)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0152 (Reserve)", + "TEXT-E": "MPCB triggered FC0152 (Reserve)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 331346.9, + 452960.1 + ] + }, + "FC0152": { + "A": "0", + "B": "FC0152", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331347.2, + 453106.6 + ] + }, + "FC0154@1": { + "IO": "FC0154", + "ID": "", + "VERW": "MS FC0154", + "BEZEICHNUNG": "MSS ausgelöst FC0154 (Reserve)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI3", + "TEXT-D": "MSS ausgelöst FC0154 (Reserve)", + "TEXT-E": "MPCB triggered FC0154 (Reserve)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 331346.9, + 452420.1 + ] + }, + "FC0154": { + "A": "0", + "B": "FC0154", + "C": "20073710081010151939", + "ARTINR": "703001017", + "BESCHR": "Hilfschalter für 3RV2011 ", + "MENGE": "1", + "POSITION": "0", + "GRUPPE": "9", + "ETIKETTE": "0", + "AUFLOESE": "N", + "pos": [ + 331347.2, + 452566.6 + ] + }, + "QA0920@1": { + "IO": "QA0920", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0140/QA0146)", + "KENNZEICHNUNG": "=A01+UC011-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0140/QA0146)", + "TEXT-E": "Main contactor activate CH 1 (QA0140/QA0146)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330195.9, + 456265.4 + ] + }, + "QA0921@1": { + "IO": "QA0921", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0140/QA0146)", + "KENNZEICHNUNG": "=A01+UC011-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0140/QA0146)", + "TEXT-E": "Main contactor activate CH 2 (QA0140/QA0146)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330204.9, + 455725.4 + ] + }, + "DI0106@1": { + "IO": "DI0106", + "ID": "9999", + "VERW": "NC", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv (QA0920/QA0921)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv (QA0920/QA0921)", + "TEXT-E": "Feedback 400V Main relay activ (QA0920/QA0921)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329462.4, + 455995.4 + ] + }, + "DI0114@1": { + "IO": "DI0114", + "ID": "9999", + "VERW": "NC", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA0922/QA0923)", + "KENNZEICHNUNG": "=A01+UC011-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA0922/QA0923)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0922/QA0923)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329462.4, + 455115.5 + ] + }, + "QA0922@1": { + "IO": "QA0922", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH06)", + "KENNZEICHNUNG": "=A01+UC011-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH06)", + "TEXT-E": "E-stop interace CH1 (zu UH06)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330204.9, + 455385.5 + ] + }, + "QA0923@1": { + "IO": "QA0923", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH06)", + "KENNZEICHNUNG": "=A01+UC011-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH06)", + "TEXT-E": "E-stop interace CH2 (zu UH06)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 330204.9, + 454845.5 + ] + }, + "SF0781@1": { + "IO": "SF0781", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH06)", + "KENNZEICHNUNG": "=A01+UC011-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH06)", + "TEXT-E": "E-stop interace CH1 (from UH06)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329462.4, + 454535.6 + ] + }, + "SF0785@1": { + "IO": "SF0785", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC011-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0X)", + "TEXT-E": "E-stop interace CH2 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 329462.4, + 454265.6 + ] + }, + "DI0166@3": { + "IO": "DI0166", + "ID": "9999", + "VERW": "NC", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv (QA1230/QA1231)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv (QA1230/QA1231)", + "TEXT-E": "Feedback 400V Main relay activ (QA1232/QA1233)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 418538.2 + ] + }, + "DI0174@3": { + "IO": "DI0174", + "ID": "9999", + "VERW": "NC", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA1232/QA1233)", + "KENNZEICHNUNG": "=A01+UC032-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA1232/QA1233)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA1232/QA1233)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 417668.8 + ] + }, + "SF1091@3": { + "IO": "SF1091", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC032-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0X)", + "TEXT-E": "E-stop interace CH1 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 417068.2 + ] + }, + "SF1095@3": { + "IO": "SF1095", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0X)", + "KENNZEICHNUNG": "=A01+UC032-KF1FDI2", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0X)", + "TEXT-E": "E-stop interace CH2 (from UH0X)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252710.8, + 416798.2 + ] + }, + "QA1230@3": { + "IO": "QA1230", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0200/QA0205)", + "KENNZEICHNUNG": "=A01+UC032-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 1 ((QA0200/QA0205)", + "TEXT-E": "Main contactor activate CH 1 (QA0200/QA0205)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253453.3, + 418808.2 + ] + }, + "QA1231@3": { + "IO": "QA1231", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0200/QA0205)", + "KENNZEICHNUNG": "=A01+UC032-KF1FDQ1", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0200/QA0205)", + "TEXT-E": "Main contactor activate CH 2 (QA0200/QA203)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253453.3, + 418268.2 + ] + }, + "QA1232@3": { + "IO": "QA1232", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC032-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253434.9, + 417938.8 + ] + }, + "QA1233@3": { + "IO": "QA1233", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UC032-KF1FDQ1", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253434.9, + 417398.8 + ] + }, + "DI0013@3": { + "IO": "DI0013", + "ID": "9999", + "VERW": "QA1540 /1541", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv", + "TEXT-E": "Feedback 400V Main relay activ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.1, + 433696.6 + ] + }, + "DI0014@3": { + "IO": "DI0014", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0660/QA0661)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.1, + 432580.9 + ] + }, + "DI0015@3": { + "IO": "DI0015", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF", + "KENNZEICHNUNG": "=A01+UH03-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0662/QA0663)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.1, + 431085.9 + ] + }, + "SF0541@3": { + "IO": "SF0541", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0x)", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI8", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0x)", + "TEXT-E": "E-stop interace CH1 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.1, + 431960.7 + ] + }, + "SF0542@3": { + "IO": "SF0542", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0x)", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI8", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0x)", + "TEXT-E": "E-stop interace CH2 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.1, + 431690.7 + ] + }, + "SF0545@3": { + "IO": "SF0545", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (from UH0x)", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI8", + "TEXT-D": "Not Halt Schnittstelle CH1 (from UH0x)", + "TEXT-E": "E-stop interace CH1 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.1, + 430467.1 + ] + }, + "SF0546@3": { + "IO": "SF0546", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (from UH0x)", + "KENNZEICHNUNG": "=A01+UH03-KF1FDI8", + "TEXT-D": "Not Halt Schnittstelle CH2 (from UH0x)", + "TEXT-E": "E-stop interace CH2 (from UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 252793.1, + 430197.1 + ] + }, + "QA0610@3": { + "IO": "QA0610", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0060 - QA0067)", + "KENNZEICHNUNG": "=A01+UH03-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0060 - QA0067)", + "TEXT-E": "Main contactor activate CH 1 (QA0060 - QA0067)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253517.2, + 434236.6 + ] + }, + "QA0611@3": { + "IO": "QA0611", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze 1 Aktivieren Kanal 2", + "KENNZEICHNUNG": "=A01+UH03-KF1FDQ6", + "TEXT-D": "Hauptschütze 1 Aktivieren Kanal 2", + "TEXT-E": "Main contactor activate CH 1 (QA0070 - QA0067)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253517.2, + 433966.6 + ] + }, + "QA0612@3": { + "IO": "QA0612", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0070 - QA0076)", + "KENNZEICHNUNG": "=A01+UH03-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0070 - QA0076)", + "TEXT-E": "Main contactor activate CH 2 (QA0070 - QA0076)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253517.2, + 433426.6 + ] + }, + "QA0613@3": { + "IO": "QA0613", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0070 - QA0076)", + "KENNZEICHNUNG": "=A01+UH03-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0070 - QA0076)", + "TEXT-E": "Main contactor activate CH 2 (QA0070 - QA0076)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253517.2, + 433156.6 + ] + }, + "QA0660@3": { + "IO": "QA0660", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH03-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253517.2, + 432850.9 + ] + }, + "QA0661@3": { + "IO": "QA0661", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH03-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253517.2, + 432310.9 + ] + }, + "QA0662@3": { + "IO": "QA0662", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH03-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253517.2, + 431355.9 + ] + }, + "QA0663@3": { + "IO": "QA0663", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH03-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "3", + "pos": [ + 253517.2, + 430815.9 + ] + }, + "DI0013@1": { + "IO": "DI0013", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv", + "TEXT-E": "Feedback 400V Main relay activ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 137170.9 + ] + }, + "DI0014@1": { + "IO": "DI0014", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "KENNZEICHNUNG": "=A01+UH01-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0660/QA0661)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 327917.1, + 136225.9 + ] + }, + "QA0610@1": { + "IO": "QA0610", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0060 - QA0067)", + "KENNZEICHNUNG": "=A01+UH01-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0060 - QA0067)", + "TEXT-E": "Main contactor activate CH 1 (QA0057 - QA0067)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328641.2, + 137440.9 + ] + }, + "QA0611@1": { + "IO": "QA0611", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0070 - QA0076)", + "KENNZEICHNUNG": "=A01+UH01-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0070 - QA0076)", + "TEXT-E": "Main contactor activate CH 1 (QA0070 - QA0076)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328641.2, + 136900.9 + ] + }, + "QA0612@1": { + "IO": "QA0612", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0057 - QA0067)", + "KENNZEICHNUNG": "=A01+UH01-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0057 - QA0067)", + "TEXT-E": "Main contactor activate CH 2 (QA0057 - QA0067)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328641.2, + 136495.9 + ] + }, + "QA0613@1": { + "IO": "QA0613", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0070 - QA0076)", + "KENNZEICHNUNG": "=A01+UH01-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0070 - QA0076)", + "TEXT-E": "Main contactor activate CH 2 (QA0070 - QA0076)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "1", + "pos": [ + 328641.2, + 135955.9 + ] + }, + "DI0013@4": { + "IO": "DI0013", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv", + "KENNZEICHNUNG": "=A01+UH04-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv", + "TEXT-E": "Feedback 400V Main relay activ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361277.5, + 729813.4 + ] + }, + "DI0014@4": { + "IO": "DI0014", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "KENNZEICHNUNG": "=A01+UH04-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0660/QA0661)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361277.5, + 728660.7 + ] + }, + "DI0015@4": { + "IO": "DI0015", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF", + "KENNZEICHNUNG": "=A01+UH04-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0662/QA0663)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361274.3, + 727099.6 + ] + }, + "QA0610@4": { + "IO": "QA0610", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0060 - QA0066)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0060 - QA0066)", + "TEXT-E": "Main contactor activate CH 1 (QA0060 - QA0066)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362001.6, + 730353.4 + ] + }, + "QA0611@4": { + "IO": "QA0611", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0070 - QA0075)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0070 - QA0075)", + "TEXT-E": "Main contactor activate CH 1 (QA0070 - QA0075)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362001.6, + 730083.4 + ] + }, + "QA0612@4": { + "IO": "QA0612", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0060 - QA0066)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0060 - QA0066)", + "TEXT-E": "Main contactor activate CH 2 (QA0060 - QA0066)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362001.6, + 729543.4 + ] + }, + "QA0613@4": { + "IO": "QA0613", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0070 - QA0075)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0070 - QA0075)", + "TEXT-E": "Main contactor activate CH 2 (QA0070 - QA0075)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362001.6, + 729273.4 + ] + }, + "QA0660@4": { + "IO": "QA0660", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362001.6, + 728930.7 + ] + }, + "QA0661@4": { + "IO": "QA0661", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 362001.6, + 728390.7 + ] + }, + "QA0662@4": { + "IO": "QA0662", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH0x)", + "TEXT-E": "E-stop interace CH1 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361998.4, + 727369.6 + ] + }, + "QA0663@4": { + "IO": "QA0663", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH0x)", + "KENNZEICHNUNG": "=A01+UH04-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH0x)", + "TEXT-E": "E-stop interace CH2 (to UH0x)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 361998.4, + 726829.6 + ] + }, + "FC0075@4": { + "IO": "FC0075", + "ID": "", + "VERW": "MS FC0075", + "BEZEICHNUNG": "MSS ausgelöst FC0075 (Reserve)", + "KENNZEICHNUNG": "=A01+UH04-KF1DI4", + "TEXT-D": "MSS ausgelöst FC0075 (Reserve)", + "TEXT-E": "MPC triggered FC0075 (Reserve)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "4", + "pos": [ + 363727.9, + 724166.5 + ] + }, + "SF0541@5": { + "IO": "SF0541", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (aus UH07)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not Halt Schnittstelle CH1 (aus UH07)", + "TEXT-E": "E-stop interace CH1 (from UH07)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210945.7, + 139049.3 + ] + }, + "SF0542@5": { + "IO": "SF0542", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (aus UH07)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not Halt Schnittstelle CH2 (aus UH07)", + "TEXT-E": "E-stop interace CH2 (from UH07)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210945.7, + 138779.3 + ] + }, + "SF0545@5": { + "IO": "SF0545", + "ID": "9999", + "VERW": "IF-IN-NC-1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (aus UH07)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not Halt Schnittstelle CH1 (aus UH07)", + "TEXT-E": "E-stop interace CH1 (from UH07)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 137536.8 + ] + }, + "SF0546@5": { + "IO": "SF0546", + "ID": "9999", + "VERW": "IF-IN-NC-2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (Reserve)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDI7", + "TEXT-D": "Not Halt Schnittstelle CH2 (Reserve)", + "TEXT-E": "E-stop interace CH2 (Reserve) ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 137266.8 + ] + }, + "DI0013@5": { + "IO": "DI0013", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Hauptschütze aktiv", + "KENNZEICHNUNG": "=A01+UH05-KF1DI1", + "TEXT-D": "Feedback Hauptschütze aktiv", + "TEXT-E": "Feedback 400V Main relay activ", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 140779.5 + ] + }, + "DI0014@5": { + "IO": "DI0014", + "ID": "9999", + "VERW": "NC-contact", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "KENNZEICHNUNG": "=A01+UH05-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0660/QA0661)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 139626.9 + ] + }, + "DI0015@5": { + "IO": "DI0015", + "ID": "9999", + "VERW": "", + "BEZEICHNUNG": "Feedback Koppelrelais E-Stop-IF", + "KENNZEICHNUNG": "=A01+UH05-KF1DI1", + "TEXT-D": "Feedback Koppelrelais E-Stop-IF", + "TEXT-E": "Feedback coupling relay E-Stop-IF (QA0662/QA0663)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 210948.8, + 138076.8 + ] + }, + "QA0610@5": { + "IO": "QA0610", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0060 - QA0067)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0060 - QA0067)", + "TEXT-E": "Main contactor activate CH 1 (QA0060 - QA0067)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211672.9, + 141319.5 + ] + }, + "QA0611@5": { + "IO": "QA0611", + "ID": "9999", + "VERW": "M-RELAY 1- CH1", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 1 (QA0070)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 1 (QA0070)", + "TEXT-E": "Main contactor activate CH 1 (QA0070)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211672.9, + 141049.5 + ] + }, + "QA0612@5": { + "IO": "QA0612", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0060 - QA0067)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0060 - QA0067)", + "TEXT-E": "Main contactor activate CH 2 (QA0060 - QA0067)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211672.9, + 140509.5 + ] + }, + "QA0613@5": { + "IO": "QA0613", + "ID": "9999", + "VERW": "M-RELAY 1- CH2", + "BEZEICHNUNG": "Hauptschütze aktivieren CH 2 (QA0070)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDQ6", + "TEXT-D": "Hauptschütze aktivieren CH 2 (QA0070)", + "TEXT-E": "Main contactor activate CH 2 (QA0070)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211672.9, + 140239.5 + ] + }, + "QA0660@5": { + "IO": "QA0660", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH07)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH07)", + "TEXT-E": "E-stop interace CH1 (to UH07)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211672.9, + 139896.9 + ] + }, + "QA0661@5": { + "IO": "QA0661", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH07)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH07)", + "TEXT-E": "E-stop interace CH2 (to UH07)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211672.9, + 139356.9 + ] + }, + "QA0662@5": { + "IO": "QA0662", + "ID": "9999", + "VERW": "IF-OUT CH1", + "BEZEICHNUNG": "Not Halt Schnittstelle CH1 (zu UH07)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH1 (zu UH07)", + "TEXT-E": "E-stop interace CH1 (to UH07)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211672.9, + 138346.8 + ] + }, + "QA0663@5": { + "IO": "QA0663", + "ID": "9999", + "VERW": "IF-OUT CH2", + "BEZEICHNUNG": "Not Halt Schnittstelle CH2 (zu UH07)", + "KENNZEICHNUNG": "=A01+UH05-KF1FDQ7", + "TEXT-D": "Not Halt Schnittstelle CH2 (zu UH07)", + "TEXT-E": "E-stop interace CH2 (to UH07)", + "TEXT-ES": "", + "TEXT-F": "", + "SPS": "5", + "pos": [ + 211672.9, + 137806.8 + ] + } + }, + "mappings": { + "UC0401": [ + "BG3260@4", + "MB3260@4", + "BG3243@4", + "BG3244@4", + "BG3240@4", + "BG3242@4", + "BG3241@4", + "BG3245@4", + "BG3262@4", + "BG3261@4", + "MB3242@4", + "BG3246@4", + "BG3253@4", + "BG3251@4", + "BG3250@4", + "BG3256@4", + "BG3252@4", + "BG3255@4", + "MB3252@4", + "MB3250@4" + ], + "UC0501": [ + "BG3260@5", + "BG3243@5", + "BG3244@5", + "BG3240@5", + "BG3242@5", + "BG3241@5", + "BG3245@5", + "MB3240@5", + "MB3245@5", + "BG3261@5", + "MB3242@5", + "BG3246@5", + "BG3253@5", + "MB3253@5", + "BG3254@5", + "BG3251@5", + "MB3251@5", + "BG3250@5", + "BG3247@5", + "BG3257@5", + "MB3257@5", + "BG3256@5", + "BG3252@5", + "BG3255@5" + ], + "UC0101": [ + "BG3260@1", + "BG3291@1", + "BG3290@1", + "BG3292@1", + "MB3260@1", + "MB3290@1", + "BG3243@1", + "BG3240@1", + "BG3283@1", + "BG3282@1", + "BG3281@1", + "BG3280@1", + "BG3286@1", + "BG3285@1", + "BG3284@1", + "BG3276@1", + "BG3275@1", + "BG3274@1", + "BG3273@1", + "BG3272@1", + "BG3271@1", + "BG3270@1", + "BG3242@1", + "BG3241@1", + "BG3245@1", + "MB3283@1", + "MB3280@1", + "MB3271@1", + "BG3262@1", + "BG3261@1", + "MB3242@1", + "MB3246@1", + "BG3246@1", + "BG3253@1", + "MB3253@1", + "BG3254@1", + "BG3251@1", + "MB3251@1", + "BG3250@1", + "BG3257@1", + "MB3257@1", + "BG3252@1", + "MB3252@1", + "MB3250@1", + "BG3263@1", + "BG3264@1", + "BG3295@1", + "BG3294@1", + "BG3293@1", + "MB3254@1", + "MB3261@1", + "MB3262@1", + "MB3264@1", + "MB3295@1", + "MB3263@1", + "BG3296@1" + ], + "U0312": [ + "BG4620@3", + "BG4622@3", + "BG4621@3", + "BG4624@3", + "BG4623@3", + "BG4625@3", + "BG4632@3", + "BG4630@3", + "BG4631@3", + "BG4640@3", + "BG4642@3", + "BG4641@3", + "MB4650@3" + ], + "UH03": [ + "MA0090@3", + "MA0091@3", + "MA0093@3", + "MA0092@3", + "MA0141@3", + "MA0144@3", + "MA0145@3", + "MA0140@3", + "MA0143@3", + "MA0142@3", + "MA0074@3", + "MA0075@3", + "MA0062@3", + "MA0061@3", + "MA0064@3", + "MA0063@3", + "MA0065@3", + "MA0066@3", + "MA0067@3", + "MA0070@3", + "MA0071@3", + "MA0073@3", + "MA0072@3", + "MA0060@3", + "BP0004@3" + ], + "UC0312": [ + "BG4633@3", + "BG4635@3", + "BG4643@3", + "BG4654@3", + "BG4653@3", + "BG4652@3", + "BG4650@3", + "BG4651@3", + "BG4644@3", + "MB4620@3", + "MB4624@3", + "MB4630@3", + "MB4633@3", + "MB4640@3", + "BG4634@3" + ], + "UC011": [ + "MA0146@1", + "MA0150@1", + "MA0141@1", + "MA0144@1", + "MA0145@1", + "MA0140@1", + "MA0151@1", + "MA0147@1", + "MA0143@1", + "MA0142@1", + "BP0107@1" + ], + "UC021": [ + "MA0146@2", + "MA0141@2", + "MA0144@2", + "MA0145@2", + "MA0140@2", + "MA0143@2", + "MA0142@2", + "BP0107@2" + ], + "UC1101": [ + "BG3006@1", + "BG3005@1", + "BG3022@1", + "BG3023@1", + "BG3001@1", + "BG3000@1", + "BG3002@1", + "BG3003@1", + "BG3004@1", + "BG3021@1", + "BG3020@1", + "BG3017@1", + "BG3024@1", + "BG3016@1", + "BG3013@1", + "BG3014@1", + "BG3012@1", + "BG3015@1", + "MB3003@1", + "MB3020@1", + "MB3024@1", + "MB3013@1", + "MB3015@1", + "BG3010@1", + "MB3010@1", + "BG3007@3", + "BG3011@1", + "BG3025@1", + "BG3027@1", + "BG3026@1", + "MB3025@1" + ], + "UC3101": [ + "BG3006@3", + "BG3005@3", + "BG3001@3", + "BG3000@3", + "BG3002@3", + "BG3003@3", + "BG3004@3", + "BG3012@3", + "BG3010@3", + "BG3011@3", + "BG3052@3", + "BG3051@3", + "BG3050@3", + "BG3047@3", + "BG3046@3", + "BG3045@3", + "BG3044@3", + "BG3043@3", + "BG3042@3", + "BG3041@3", + "BG3040@3", + "BG3037@3", + "BG3036@3", + "BG3035@3", + "BG3034@3", + "BG3033@3", + "BG3032@3", + "BG3031@3", + "BG3030@3", + "MB3045@3", + "MB3046@3", + "MB3047@3", + "MB3050@3", + "MB3051@3", + "MB3052@3", + "MB3030@3", + "MB3031@3", + "MB3032@3", + "MB3033@3", + "MB3034@3", + "MB3035@3", + "MB3036@3", + "MB3000@3", + "MB3004@3", + "MB3044@3", + "MB3043@3", + "MB3042@3", + "MB3041@3", + "MB3040@3", + "MB3037@3" + ], + "UC2101": [ + "BG3006@2", + "BG3005@2", + "BG3001@2", + "BG3000@2", + "BG3002@2", + "BG3003@2", + "BG3004@2", + "BG3012@2", + "BG3010@2", + "BG3007@2", + "BG3011@2", + "BG3052@2", + "BG3051@2", + "BG3050@2", + "BG3047@2", + "BG3046@2", + "BG3045@2", + "BG3044@2", + "BG3043@2", + "BG3042@2", + "BG3041@2", + "BG3040@2", + "BG3037@2", + "BG3036@2", + "BG3035@2", + "BG3034@2", + "BG3033@2", + "BG3032@2", + "BG3031@2", + "BG3030@2", + "MB3045@2", + "MB3046@2", + "MB3047@2", + "MB3050@2", + "MB3051@2", + "MB3052@2", + "MB3030@2", + "MB3031@2", + "MB3032@2", + "MB3033@2", + "MB3034@2", + "MB3035@2", + "MB3036@2", + "MB3000@2", + "MB3004@2", + "MB3044@2", + "MB3043@2", + "MB3042@2", + "MB3041@2", + "MB3040@2", + "MB3037@2" + ], + "UC1103": [ + "BG3124@1", + "BG3130@1", + "BG3131@1", + "BG3137@1", + "BG3135@1", + "BG3136@1", + "BG3125@1", + "BG3133@1", + "BG3134@1", + "BG3126@1", + "BG3121@1", + "BG3120@1", + "MB3135@1", + "MB3125@1", + "MB3120@1", + "MB3130@1", + "BG3123@1", + "BG3132@1", + "BG3127@1", + "BG3122@1" + ], + "UC3103": [ + "BG3124@3", + "BG3130@3", + "BG3131@3", + "BG3137@3", + "BG3135@3", + "BG3136@3", + "BG3125@3", + "BG3133@3", + "BG3134@3", + "BG3126@3", + "BG3121@3", + "BG3120@3", + "MB3135@3", + "MB3120@3", + "BG3123@3", + "BG3132@3", + "BG3127@3", + "BG3122@3", + "BG3150@3", + "BG3151@3", + "BG3152@3", + "BG3153@3", + "BG3154@3", + "BG3155@3", + "BG3156@3", + "BG3157@3", + "BG3160@3", + "BG3161@3", + "BG3162@3", + "BG3163@3", + "BG3164@3", + "BG3165@3", + "BG3166@3", + "BG3167@3", + "BG3170@3", + "BG3171@3", + "BG3172@3", + "BG3174@3", + "BG3173@3", + "MB3150@3", + "MB3151@3", + "MB3152@3", + "MB3153@3", + "MB3154@3", + "MB3155@3", + "MB3156@3", + "MB3157@3", + "MB3160@3", + "MB3161@3", + "MB3162@3", + "MB3163@3", + "MB3164@3", + "MB3165@3", + "MB3166@3", + "MB3167@3", + "MB3170@3", + "MB3171@3", + "MB3172@3", + "MB3173@3", + "MB3174@3", + "MB3137@3", + "MB3124@3", + "MB3134@3", + "BG3140@3" + ], + "UC2103": [ + "BG3124@2", + "BG3130@2", + "BG3131@2", + "BG3137@2", + "BG3135@2", + "BG3136@2", + "BG3125@2", + "BG3133@2", + "BG3134@2", + "BG3126@2", + "BG3121@2", + "BG3120@2", + "MB3120@2", + "BG3123@2", + "BG3132@2", + "BG3127@2", + "BG3122@2", + "BG3150@2", + "BG3151@2", + "BG3152@2", + "BG3153@2", + "BG3154@2", + "BG3155@2", + "BG3156@2", + "BG3157@2", + "BG3160@2", + "BG3161@2", + "BG3162@2", + "BG3163@2", + "BG3164@2", + "BG3165@2", + "BG3166@2", + "BG3167@2", + "BG3170@2", + "BG3171@2", + "BG3172@2", + "BG3174@2", + "BG3173@2", + "BG3144@2", + "BG3143@2", + "BG3145@2", + "MB3150@2", + "MB3151@2", + "MB3152@2", + "MB3153@2", + "MB3154@2", + "MB3155@2", + "MB3156@2", + "MB3157@2", + "MB3160@2", + "MB3161@2", + "MB3162@2", + "MB3163@2", + "MB3164@2", + "MB3165@2", + "MB3166@2", + "MB3167@2", + "MB3170@2", + "MB3171@2", + "MB3172@2", + "MB3173@2", + "MB3174@2", + "MB3137@2", + "MB3124@2", + "MB3134@2", + "MB3143@2", + "BG3141@2", + "BG3142@2" + ], + "UC1102": [ + "BG3060@1", + "BG3062@1", + "BG3061@1", + "BG3065@1", + "BG3063@1", + "BG3064@1", + "BG3075@1", + "BG3074@1", + "BG3071@1", + "BG3070@1", + "BG3072@1", + "BG3073@1", + "BG3066@1", + "BG3067@1", + "MB3060@1", + "MB3063@1", + "MB3073@1", + "BG3076@1", + "MB3076@1", + "BG3077@1", + "BG3080@1", + "BG3081@1", + "MB3080@1", + "BG3082@1" + ], + "UC3102": [ + "BG3060@3", + "BG3062@3", + "BG3061@3", + "BG3065@3", + "BG3063@3", + "BG3064@3", + "BG3071@3", + "BG3070@3", + "BG3072@3", + "BG3073@3", + "BG3066@3", + "BG3067@3", + "MB3060@3", + "BG3110@3", + "BG3107@3", + "BG3106@3", + "BG3105@3", + "BG3095@3", + "BG3094@3", + "BG3093@3", + "BG3092@3", + "BG3091@3", + "BG3090@3", + "BG3096@3", + "BG3097@3", + "BG3104@3", + "BG3103@3", + "BG3102@3", + "BG3101@3", + "BG3100@3", + "MB3064@3", + "MB3090@3", + "MB3091@3", + "MB3092@3", + "MB3093@3", + "MB3094@3", + "MB3095@3", + "MB3096@3", + "MB3097@3", + "MB3104@3", + "MB3103@3", + "MB3102@3", + "MB3101@3", + "MB3100@3", + "MB3105@3", + "MB3106@3", + "MB3107@3", + "MB3110@3", + "MB3061@3" + ], + "UC2102": [ + "BG3060@2", + "BG3062@2", + "BG3061@2", + "BG3065@2", + "BG3063@2", + "BG3064@2", + "BG3071@2", + "BG3070@2", + "BG3072@2", + "BG3073@2", + "BG3066@2", + "BG3067@2", + "MB3060@2", + "BG3110@2", + "BG3107@2", + "BG3106@2", + "BG3105@2", + "BG3095@2", + "BG3094@2", + "BG3093@2", + "BG3092@2", + "BG3091@2", + "BG3090@2", + "BG3096@2", + "BG3097@2", + "BG3104@2", + "BG3103@2", + "BG3102@2", + "BG3101@2", + "BG3100@2", + "MB3064@2", + "MB3090@2", + "MB3091@2", + "MB3092@2", + "MB3093@2", + "MB3094@2", + "MB3095@2", + "MB3096@2", + "MB3097@2", + "MB3104@2", + "MB3103@2", + "MB3102@2", + "MB3101@2", + "MB3100@2", + "MB3105@2", + "MB3106@2", + "MB3107@2", + "MB3110@2", + "MB3061@2" + ], + "UC0301": [ + "BG3291@3", + "BG3290@3", + "BG3292@3", + "MB3290@3", + "BG3243@3", + "BG3244@3", + "BG3240@3", + "BG3283@3", + "BG3282@3", + "BG3281@3", + "BG3280@3", + "BG3277@3", + "BG3286@3", + "BG3285@3", + "BG3284@3", + "BG3287@3", + "BG3276@3", + "BG3275@3", + "BG3274@3", + "BG3273@3", + "BG3272@3", + "BG3271@3", + "BG3270@3", + "BG3242@3", + "BG3241@3", + "BG3245@3", + "MB3244@3", + "MB3240@3", + "MB3292@3", + "MB3283@3", + "MB3282@3", + "MB3281@3", + "MB3280@3", + "MB3277@3", + "MB3286@3", + "MB3285@3", + "MB3284@3", + "MB3287@3", + "MB3291@3", + "MB3276@3", + "MB3275@3", + "MB3274@3", + "MB3273@3", + "MB3272@3", + "MB3271@3", + "MB3270@3", + "MB3241@3", + "MB3245@3", + "BG3247@3" + ], + "UC0201": [ + "BG3291@2", + "BG3290@2", + "BG3292@2", + "MB3290@2", + "BG3243@2", + "BG3244@2", + "BG3240@2", + "BG3283@2", + "BG3282@2", + "BG3281@2", + "BG3280@2", + "BG3277@2", + "BG3286@2", + "BG3285@2", + "BG3284@2", + "BG3287@2", + "BG3276@2", + "BG3275@2", + "BG3274@2", + "BG3273@2", + "BG3272@2", + "BG3271@2", + "BG3270@2", + "BG3242@2", + "BG3241@2", + "BG3245@2", + "MB3244@2", + "MB3240@2", + "MB3292@2", + "MB3283@2", + "MB3282@2", + "MB3281@2", + "MB3280@2", + "MB3277@2", + "MB3286@2", + "MB3285@2", + "MB3284@2", + "MB3287@2", + "MB3291@2", + "MB3276@2", + "MB3275@2", + "MB3274@2", + "MB3273@2", + "MB3272@2", + "MB3271@2", + "MB3270@2", + "MB3241@2", + "MB3245@2", + "BG3247@2" + ], + "UC0209": [ + "BG4462@2", + "BG4461@2", + "BG4444@2", + "BG4440@2", + "BG4442@2", + "BG4443@2", + "BG4460@2", + "MB4460@2", + "MB4444@2", + "MB4440@2", + "MB4455@2", + "BG4455@2", + "BG4451@2", + "BG4445@2", + "BG4447@2", + "BG4446@2", + "BG4454@2", + "BG4453@2", + "MB4451@2", + "MB4445@2" + ], + "UC0311": [ + "BG4575@3", + "BG4562@3", + "BG4560@3", + "BG4577@3", + "BG4565@3", + "BG4574@3", + "BG4566@3", + "BG4567@3", + "BG4570@3", + "BG4573@3", + "BG4572@3", + "BG4571@3", + "BG4564@3", + "MB4575@3", + "MB4562@3", + "MB4560@3", + "MB4566@3", + "MB4572@3", + "BG4563@3" + ], + "UC0211": [ + "BG4562@2", + "BG4560@2", + "BG4565@2", + "BG4567@2", + "BG4564@2", + "MB4562@2", + "BG4561@2", + "BG4563@2", + "MB4563@2", + "BG4531@2", + "BG4533@2" + ], + "UH02": [ + "MA0074@2", + "MA0075@2", + "MA0062@2", + "MA0061@2", + "MA0064@2", + "MA0063@2", + "MA0065@2", + "MA0066@2", + "MA0067@2", + "MA0070@2", + "MA0071@2", + "MA0073@2", + "MA0072@2", + "MA0060@2", + "MA0076@2", + "BP0004@2" + ], + "UH01": [ + "MA0074@1", + "MA0062@1", + "MA0061@1", + "MA0064@1", + "MA0063@1", + "MA0065@1", + "MA0066@1", + "MA0067@1", + "MA0070@1", + "MA0072@1", + "MA0060@1", + "MA0076@1", + "BG0053@1", + "BG0052@1", + "MA0057@1", + "BP0004@1" + ], + "UH04": [ + "MA0074@4", + "MA0062@4", + "MA0061@4", + "MA0064@4", + "MA0063@4", + "MA0065@4", + "MA0066@4", + "MA0070@4", + "MA0071@4", + "MA0073@4", + "MA0072@4", + "MA0060@4", + "BP0004@4" + ], + "UC3104": [ + "BG3187@3", + "BG3191@3", + "BG3190@3", + "BG3180@3", + "BG3184@3", + "BG3185@3", + "BG3181@3", + "BG3182@3", + "BG3210@3", + "BG3211@3", + "BG3212@3", + "BG3213@3", + "BG3214@3", + "BG3215@3", + "BG3216@3", + "BG3217@3", + "BG3221@3", + "BG3222@3", + "BG3223@3", + "BG3224@3", + "BG3220@3", + "BG3194@3", + "BG3183@3", + "BG3186@3", + "BG3192@3", + "BG3193@3", + "MB3180@3", + "MB3184@3", + "MB3210@3", + "MB3211@3", + "MB3212@3", + "MB3213@3", + "MB3214@3", + "MB3215@3", + "MB3216@3", + "MB3217@3", + "MB3220@3", + "MB3221@3", + "MB3222@3", + "MB3223@3", + "MB3224@3", + "MB3192@3" + ], + "UC2104": [ + "BG3187@2", + "BG3191@2", + "BG3190@2", + "BG3180@2", + "BG3184@2", + "BG3185@2", + "BG3181@2", + "BG3182@2", + "BG3210@2", + "BG3211@2", + "BG3212@2", + "BG3213@2", + "BG3214@2", + "BG3215@2", + "BG3216@2", + "BG3217@2", + "BG3221@2", + "BG3222@2", + "BG3223@2", + "BG3224@2", + "BG3220@2", + "BG3183@2", + "BG3186@2", + "BG3192@2", + "MB3180@2", + "MB3184@2", + "MB3210@2", + "MB3211@2", + "MB3212@2", + "MB3213@2", + "MB3214@2", + "MB3215@2", + "MB3216@2", + "MB3217@2", + "MB3220@2", + "MB3221@2", + "MB3222@2", + "MB3223@2", + "MB3224@2" + ], + "UH05": [ + "MA0062@5", + "MA0061@5", + "MA0064@5", + "MA0063@5", + "MA0065@5", + "MA0066@5", + "MA0067@5", + "MA0070@5", + "MA0060@5", + "BP0004@5" + ], + "UC032": [ + "MA0200@3", + "MA0201@3", + "MA0202@3", + "MA0203@3", + "MA0204@3", + "MA0205@3", + "BP0167@3" + ], + "UC022": [ + "MA0200@2", + "MA0201@2", + "MA0202@2", + "MA0203@2", + "BP0167@2" + ], + "UC0302": [ + "BG3303@3", + "BG3304@3", + "BG3301@3", + "BG3300@3", + "BG3302@3", + "BG3306@3", + "BG3305@3", + "MB3304@3", + "MB3300@3", + "MB3301@3", + "MB3336@3", + "MB3335@3", + "MB3334@3", + "MB3333@3", + "MB3332@3", + "MB3331@3", + "MB3330@3", + "MB3343@3", + "MB3342@3", + "MB3341@3", + "MB3340@3", + "MB3337@3", + "MB3344@3", + "MB3346@3", + "MB3345@3", + "MB3347@3", + "MB3350@3", + "MB3306@3", + "BG3307@3" + ], + "UC0202": [ + "BG3303@2", + "BG3304@2", + "BG3301@2", + "BG3300@2", + "BG3302@2", + "BG3336@3", + "BG3336@2", + "BG3335@3", + "BG3335@2", + "BG3334@3", + "BG3334@2", + "BG3333@3", + "BG3333@2", + "BG3332@3", + "BG3332@2", + "BG3331@3", + "BG3331@2", + "BG3330@3", + "BG3330@2", + "BG3343@3", + "BG3343@2", + "BG3342@3", + "BG3342@2", + "BG3341@3", + "BG3341@2", + "BG3340@3", + "BG3340@2", + "BG3337@3", + "BG3337@2", + "BG3344@3", + "BG3344@2", + "BG3346@3", + "BG3346@2", + "BG3345@3", + "BG3345@2", + "BG3347@3", + "BG3347@2", + "BG3350@3", + "BG3350@2", + "BG3306@2", + "BG3305@2", + "MB3304@2", + "MB3300@2", + "MB3301@2", + "MB3336@2", + "MB3335@2", + "MB3334@2", + "MB3333@2", + "MB3332@2", + "MB3331@2", + "MB3330@2", + "MB3343@2", + "MB3342@2", + "MB3341@2", + "MB3340@2", + "MB3337@2", + "MB3344@2", + "MB3346@2", + "MB3345@2", + "MB3347@2", + "MB3350@2", + "MB3306@2", + "BG3307@2" + ], + "UC0502": [ + "BG3303@5", + "BG3304@5", + "BG3301@5", + "BG3300@5", + "BG3302@5", + "BG3335@5", + "BG3334@5", + "BG3333@5", + "BG3332@5", + "BG3331@5", + "BG3330@5", + "BG3306@5", + "BG3305@5", + "MB3304@5", + "MB3301@5", + "MB3333@5", + "MB3330@5", + "MB3306@5", + "BG3307@5", + "MB3307@5", + "BG3312@5", + "MB3312@5", + "BG3310@5", + "BG3321@5", + "BG3313@5", + "MB3313@5", + "BG3316@5", + "MB3316@5", + "BG3315@5", + "BG3320@5", + "BG3317@5", + "BG3314@5", + "MB3314@5", + "BG3324@5", + "BG3322@5", + "MB3322@5", + "BG3323@5" + ], + "UC0402": [ + "BG3303@4", + "BG3304@4", + "BG3301@4", + "BG3300@4", + "MB3304@4", + "MB3300@4", + "MB3306@4", + "BG3312@4", + "BG3310@4", + "BG3321@4", + "BG3313@4", + "BG3316@4", + "BG3315@4", + "BG3320@4", + "BG3317@4", + "BG3314@4", + "BG3324@4", + "BG3322@4", + "BG3311@4", + "MB3321@4", + "MB3310@4", + "BG3325@4" + ], + "UC0102": [ + "BG3304@1", + "BG3335@1", + "BG3334@1", + "BG3332@1", + "BG3331@1", + "BG3330@1", + "BG3343@1", + "BG3342@1", + "BG3341@1", + "BG3340@1", + "BG3337@1", + "BG3344@1", + "BG3346@1", + "BG3345@1", + "BG3306@1", + "BG3305@1", + "MB3304@1", + "MB3300@1", + "MB3335@1", + "MB3332@1", + "MB3330@1", + "MB3340@1", + "MB3337@1", + "MB3306@1", + "BG3312@1", + "MB3312@1", + "BG3310@1", + "BG3321@1", + "BG3313@1", + "MB3313@1", + "BG3315@1", + "BG3320@1", + "BG3314@1", + "MB3314@1", + "BG3324@1", + "BG3322@1", + "MB3322@1", + "BG3323@1", + "BG3311@1", + "MB3321@1", + "MB3310@1", + "BG3325@1", + "MB3311@1", + "MB3323@1", + "MB3324@1", + "MB3320@1", + "MB3315@1", + "MB3325@1", + "BG3357@1", + "BG3355@1", + "BG3354@1", + "BG3356@1" + ], + "UC0303": [ + "BG3363@3", + "BG3364@3", + "BG3361@3", + "BG3362@3", + "BG3360@3", + "MB3364@3", + "MB3361@3", + "MB3360@3", + "MB3390@3", + "MB3391@3", + "MB3392@3", + "MB3393@3", + "MB3394@3", + "MB3395@3", + "MB3396@3", + "MB3397@3", + "MB3400@3", + "MB3401@3", + "MB3402@3", + "MB3403@3", + "MB3404@3", + "MB3405@3", + "MB3406@3", + "MB3407@3", + "MB3410@3", + "MB3411@3", + "MB3412@3", + "MB3413@3", + "MB3414@3", + "BG3367@3", + "BG3365@3" + ], + "UC0203": [ + "BG3363@2", + "BG3364@2", + "BG3361@2", + "BG3362@2", + "BG3360@2", + "BG3390@3", + "BG3390@2", + "BG3391@3", + "BG3391@2", + "BG3392@3", + "BG3392@2", + "BG3393@3", + "BG3393@2", + "BG3394@3", + "BG3394@2", + "BG3395@3", + "BG3395@2", + "BG3396@3", + "BG3396@2", + "BG3397@3", + "BG3397@2", + "BG3400@3", + "BG3400@2", + "BG3401@3", + "BG3401@2", + "BG3402@3", + "BG3402@2", + "BG3403@3", + "BG3403@2", + "BG3404@3", + "BG3404@2", + "BG3405@3", + "BG3405@2", + "BG3406@3", + "BG3406@2", + "BG3407@3", + "BG3407@2", + "BG3410@3", + "BG3410@2", + "BG3411@3", + "BG3411@2", + "BG3412@3", + "BG3412@2", + "BG3413@3", + "BG3413@2", + "BG3414@3", + "BG3414@2", + "MB3364@2", + "MB3361@2", + "MB3360@2", + "MB3390@2", + "MB3391@2", + "MB3392@2", + "MB3393@2", + "MB3394@2", + "MB3395@2", + "MB3396@2", + "MB3397@2", + "MB3400@2", + "MB3401@2", + "MB3402@2", + "MB3403@2", + "MB3404@2", + "MB3405@2", + "MB3406@2", + "MB3407@2", + "MB3410@2", + "MB3411@2", + "MB3412@2", + "MB3413@2", + "MB3414@2", + "BG3367@2", + "BG3365@2" + ], + "UC0503": [ + "BG3363@5", + "BG3364@5", + "BG3361@5", + "BG3362@5", + "BG3360@5", + "MB3364@5", + "MB3361@5", + "MB3360@5", + "BG3367@5", + "BG3381@5", + "BG3366@5", + "BG3365@5", + "MB3362@5", + "BG3370@5", + "MB3370@5", + "BG3371@5", + "BG3372@5", + "MB3372@5", + "BG3373@5", + "MB3373@5", + "BG3376@5", + "MB3376@5", + "BG3375@5", + "BG3380@5", + "BG3377@5", + "BG3374@5", + "MB3374@5", + "BG3382@5", + "MB3382@5", + "BG3383@5", + "BG3384@5", + "BG3385@5" + ], + "UC0403": [ + "BG3363@4", + "BG3362@4", + "BG3360@4", + "BG3390@4", + "BG3391@4", + "BG3392@4", + "BG3393@4", + "MB3360@4", + "MB3391@4", + "BG3367@4", + "BG3381@4", + "MB3362@4", + "BG3370@4", + "MB3370@4", + "BG3371@4", + "BG3372@4", + "BG3373@4", + "BG3376@4", + "BG3375@4", + "BG3380@4", + "BG3377@4", + "BG3374@4", + "BG3382@4", + "BG3383@4", + "BG3386@4", + "BG3387@4", + "MB3363@4", + "MB3386@4", + "MB3366@4", + "MB3381@4", + "MB3383@4", + "BG3384@4" + ], + "UC0304": [ + "BG3423@3", + "BG3424@3", + "BG3421@3", + "BG3422@3", + "BG3420@3", + "BG3425@3", + "BG3426@3", + "BG3450@3", + "BG3451@3", + "BG3452@3", + "BG3453@3", + "BG3454@3", + "BG3455@3", + "BG3456@3", + "BG3457@3", + "BG3460@3", + "BG3461@3", + "BG3462@3", + "BG3463@3", + "BG3464@3", + "BG3431@3", + "BG3432@3", + "BG3434@3", + "BG3433@3", + "BG3435@3", + "BG3436@3", + "MB3424@3", + "MB3421@3", + "MB3420@3", + "MB3425@3", + "MB3450@3", + "MB3451@3", + "MB3452@3", + "MB3453@3", + "MB3454@3", + "MB3455@3", + "MB3456@3", + "MB3457@3", + "MB3460@3", + "MB3461@3", + "MB3462@3", + "MB3463@3", + "MB3464@3", + "MB3905@3", + "MB3431@3", + "MB3432@3", + "BG3440@3", + "BG3442@3", + "BG3441@3", + "MB3440@3", + "BG3427@3" + ], + "UC0204": [ + "BG3423@2", + "BG3424@2", + "BG3421@2", + "BG3422@2", + "BG3420@2", + "BG3425@2", + "BG3426@2", + "BG3450@2", + "BG3451@2", + "BG3452@2", + "BG3453@2", + "BG3454@2", + "BG3455@2", + "BG3456@2", + "BG3457@2", + "BG3460@2", + "BG3461@2", + "BG3462@2", + "BG3463@2", + "BG3464@2", + "BG3431@2", + "BG3433@2", + "MB3424@2", + "MB3421@2", + "MB3420@2", + "MB3425@2", + "MB3450@2", + "MB3451@2", + "MB3452@2", + "MB3453@2", + "MB3454@2", + "MB3455@2", + "MB3456@2", + "MB3457@2", + "MB3460@2", + "MB3461@2", + "MB3462@2", + "MB3463@2", + "MB3464@2", + "BG3430@2", + "MB3426@2", + "BG3427@2" + ], + "UC0504": [ + "BG3423@5", + "BG3424@5", + "BG3421@5", + "BG3422@5", + "BG3420@5", + "BG3425@5", + "BG3426@5", + "BG3431@5", + "BG3432@5", + "BG3434@5", + "BG3433@5", + "BG3435@5", + "BG3436@5", + "MB3424@5", + "MB3421@5", + "MB3420@5", + "MB3432@5", + "BG3440@1", + "BG3442@1", + "BG3441@1", + "BG3430@5", + "BG3427@5", + "MB3430@5", + "MB3422@5", + "MB3433@5", + "BG3443@1", + "BG3437@5", + "MB3436@5" + ], + "UC0404": [ + "BG3423@4", + "BG3424@4", + "BG3421@4", + "BG3420@4", + "BG3425@4", + "BG3426@4", + "BG3450@4", + "BG3451@4", + "BG3454@4", + "BG3455@4", + "BG3431@4", + "BG3434@4", + "BG3433@4", + "BG3435@4", + "MB3424@4", + "MB3420@4", + "MB3451@4", + "MB3432@4", + "BG3442@4", + "BG3441@4", + "BG3430@4", + "MB3440@4", + "MB3430@4", + "MB3435@4", + "BG3444@4", + "BG3447@4", + "BG3446@4", + "BG3443@4", + "BG3445@4", + "BG3385@4" + ], + "UC0305": [ + "BG3480@3", + "BG3484@3", + "BG3483@3", + "BG3485@3", + "BG3487@3", + "BG3490@3", + "BG3491@3", + "BG3481@3", + "BG3482@3", + "BG3524@3", + "BG3523@3", + "BG3516@3", + "BG3515@3", + "BG3514@3", + "BG3513@3", + "BG3512@3", + "BG3511@3", + "BG3510@3", + "BG3522@3", + "BG3521@3", + "BG3520@3", + "BG3517@3", + "MB3510@3", + "MB3511@3", + "MB3512@3", + "MB3513@3", + "MB3514@3", + "MB3515@3", + "MB3516@3", + "MB3480@3", + "MB3484@3", + "MB3524@3", + "MB3523@3", + "MB3522@3", + "MB3521@3", + "MB3520@3", + "MB3517@3" + ], + "UC0205": [ + "BG3480@2", + "BG3484@2", + "BG3483@2", + "BG3485@2", + "BG3487@2", + "BG3490@2", + "BG3491@2", + "BG3481@2", + "BG3482@2", + "BG3524@2", + "BG3523@2", + "BG3516@2", + "BG3515@2", + "BG3514@2", + "BG3513@2", + "BG3512@2", + "BG3511@2", + "BG3510@2", + "BG3522@2", + "BG3521@2", + "BG3520@2", + "BG3517@2", + "BG3486@3", + "BG3486@2", + "MB3510@2", + "MB3511@2", + "MB3512@2", + "MB3513@2", + "MB3514@2", + "MB3515@2", + "MB3516@2", + "MB3480@2", + "MB3484@2", + "MB3524@2", + "MB3523@2", + "MB3522@2", + "MB3521@2", + "MB3520@2", + "MB3517@2", + "BG3492@2", + "BG3532@2", + "BG3531@2", + "BG3530@2", + "BG3527@2", + "BG3526@2", + "BG3525@2", + "MB3525@2", + "MB3526@2", + "MB3527@2", + "MB3530@2", + "MB3531@2", + "MB3532@2" + ], + "UC0306": [ + "BG3540@3", + "BG3544@3", + "BG3545@3", + "BG3543@3", + "BG3550@3", + "BG3541@3", + "BG3542@3", + "BG3551@3", + "BG3590@3", + "BG3587@3", + "BG3586@3", + "BG3585@3", + "BG3552@3", + "BG3575@3", + "BG3574@3", + "BG3573@3", + "BG3572@3", + "BG3571@3", + "BG3570@3", + "BG3576@3", + "BG3577@3", + "BG3584@3", + "BG3583@3", + "BG3582@3", + "BG3581@3", + "BG3580@3", + "BG3547@3", + "MB3540@3", + "MB3544@3", + "MB3570@3", + "MB3571@3", + "MB3572@3", + "MB3573@3", + "MB3574@3", + "MB3575@3", + "MB3576@3", + "MB3577@3", + "MB3584@3", + "MB3583@3", + "MB3582@3", + "MB3581@3", + "MB3580@3", + "MB3585@3", + "MB3586@3", + "MB3587@3", + "MB3590@3", + "MB3541@3", + "BG3553@3" + ], + "UC0206": [ + "BG3540@2", + "BG3544@2", + "BG3545@2", + "BG3543@2", + "BG3550@2", + "BG3541@2", + "BG3542@2", + "BG3551@2", + "BG3590@2", + "BG3587@2", + "BG3586@2", + "BG3585@2", + "BG3552@2", + "BG3575@2", + "BG3574@2", + "BG3573@2", + "BG3572@2", + "BG3571@2", + "BG3570@2", + "BG3576@2", + "BG3577@2", + "BG3584@2", + "BG3583@2", + "BG3582@2", + "BG3581@2", + "BG3580@2", + "BG3547@2", + "BG3546@3", + "BG3546@2", + "MB3540@2", + "MB3544@2", + "MB3570@2", + "MB3571@2", + "MB3572@2", + "MB3573@2", + "MB3574@2", + "MB3575@2", + "MB3576@2", + "MB3577@2", + "MB3584@2", + "MB3583@2", + "MB3582@2", + "MB3581@2", + "MB3580@2", + "MB3585@2", + "MB3586@2", + "MB3587@2", + "MB3590@2", + "MB3541@2", + "BG3553@2" + ], + "UC0307": [ + "BG3617@3", + "BG3613@3", + "BG3612@3", + "BG3611@3", + "BG3610@3", + "BG3607@3", + "BG3600@3", + "BG3604@3", + "BG3605@3", + "BG3603@3", + "BG3601@3", + "BG3602@3", + "BG3630@3", + "BG3631@3", + "BG3632@3", + "BG3633@3", + "BG3634@3", + "BG3635@3", + "BG3637@3", + "BG3640@3", + "BG3641@3", + "BG3642@3", + "BG3643@3", + "BG3644@3", + "BG3645@3", + "BG3646@3", + "BG3647@3", + "BG3650@3", + "BG3651@3", + "BG3652@3", + "BG3654@3", + "BG3653@3", + "BG3615@3", + "BG3614@3", + "BG3616@3", + "MB3630@3", + "MB3631@3", + "MB3632@3", + "MB3633@3", + "MB3634@3", + "MB3635@3", + "MB3636@3", + "MB3637@3", + "MB3640@3", + "MB3641@3", + "MB3642@3", + "MB3643@3", + "MB3644@3", + "MB3645@3", + "MB3646@3", + "MB3647@3", + "MB3650@3", + "MB3651@3", + "MB3652@3", + "MB3653@3", + "MB3654@3", + "MB3617@3", + "MB3600@3", + "MB3604@3", + "MB3614@3", + "MB3615@3", + "BG3625@3" + ], + "UC0207": [ + "BG3617@2", + "BG3613@2", + "BG3612@2", + "BG3611@2", + "BG3610@2", + "BG3607@2", + "BG3600@2", + "BG3604@2", + "BG3605@2", + "BG3603@2", + "BG3601@2", + "BG3602@2", + "BG3630@2", + "BG3631@2", + "BG3632@2", + "BG3633@2", + "BG3634@2", + "BG3635@2", + "BG3636@2", + "BG3637@2", + "BG3640@2", + "BG3641@2", + "BG3642@2", + "BG3643@2", + "BG3644@2", + "BG3645@2", + "BG3646@2", + "BG3647@2", + "BG3650@2", + "BG3651@2", + "BG3652@2", + "BG3654@2", + "BG3653@2", + "BG3606@3", + "BG3606@2", + "BG3623@2", + "BG3622@2", + "BG3624@2", + "BG3615@2", + "BG3614@2", + "BG3616@2", + "MB3630@2", + "MB3631@2", + "MB3632@2", + "MB3633@2", + "MB3634@2", + "MB3635@2", + "MB3636@2", + "MB3637@2", + "MB3640@2", + "MB3641@2", + "MB3642@2", + "MB3643@2", + "MB3644@2", + "MB3645@2", + "MB3646@2", + "MB3647@2", + "MB3650@2", + "MB3651@2", + "MB3652@2", + "MB3653@2", + "MB3654@2", + "MB3617@2", + "MB3600@2", + "MB3604@2", + "MB3622@2", + "MB3614@2", + "BG3621@2", + "BG3625@2" + ], + "UC0308": [ + "BG3667@3", + "BG3671@3", + "BG3670@3", + "BG3660@3", + "BG3664@3", + "BG3665@3", + "BG3661@3", + "BG3662@3", + "BG3690@3", + "BG3691@3", + "BG3692@3", + "BG3693@3", + "BG3694@3", + "BG3695@3", + "BG3696@3", + "BG3697@3", + "BG3701@3", + "BG3702@3", + "BG3703@3", + "BG3704@3", + "BG3700@3", + "BG3674@3", + "BG3663@3", + "BG3672@3", + "MB3660@3", + "MB3664@3", + "MB3690@3", + "MB3691@3", + "MB3692@3", + "MB3693@3", + "MB3694@3", + "MB3695@3", + "MB3696@3", + "MB3697@3", + "MB3700@3", + "MB3701@3", + "MB3702@3", + "MB3703@3", + "MB3704@3", + "MB3672@3", + "MB3673@3", + "BG3673@3" + ], + "UC0208": [ + "BG3667@2", + "BG3671@2", + "BG3670@2", + "BG3660@2", + "BG3664@2", + "BG3665@2", + "BG3661@2", + "BG3662@2", + "BG3690@2", + "BG3691@2", + "BG3692@2", + "BG3693@2", + "BG3694@2", + "BG3695@2", + "BG3696@2", + "BG3697@2", + "BG3701@2", + "BG3702@2", + "BG3703@2", + "BG3704@2", + "BG3700@2", + "BG3663@2", + "BG3666@3", + "BG3666@2", + "BG3672@2", + "MB3660@2", + "MB3664@2", + "MB3690@2", + "MB3691@2", + "MB3692@2", + "MB3693@2", + "MB3694@2", + "MB3695@2", + "MB3696@2", + "MB3697@2", + "MB3700@2", + "MB3701@2", + "MB3702@2", + "MB3703@2", + "MB3704@2" + ], + "UC3201": [ + "BG3723@3", + "BG3724@3", + "BG3720@3", + "BG3763@3", + "BG3762@3", + "BG3761@3", + "BG3760@3", + "BG3757@3", + "BG3764@3", + "BG3756@3", + "BG3755@3", + "BG3754@3", + "BG3753@3", + "BG3752@3", + "BG3751@3", + "BG3750@3", + "BG3722@3", + "BG3721@3", + "BG3725@3", + "MB3724@3", + "MB3720@3", + "MB3763@3", + "MB3762@3", + "MB3761@3", + "MB3760@3", + "MB3757@3", + "MB3764@3", + "MB3756@3", + "MB3755@3", + "MB3754@3", + "MB3753@3", + "MB3752@3", + "MB3751@3", + "MB3750@3", + "MB3721@3", + "MB3725@3" + ], + "UC2201": [ + "BG3723@2", + "BG3724@2", + "BG3720@2", + "BG3763@2", + "BG3762@2", + "BG3761@2", + "BG3760@2", + "BG3757@2", + "BG3764@2", + "BG3756@2", + "BG3755@2", + "BG3754@2", + "BG3753@2", + "BG3752@2", + "BG3751@2", + "BG3750@2", + "BG3722@2", + "BG3721@2", + "BG3725@2", + "MB3724@2", + "MB3720@2", + "MB3763@2", + "MB3762@2", + "MB3761@2", + "MB3760@2", + "MB3757@2", + "MB3764@2", + "MB3756@2", + "MB3755@2", + "MB3754@2", + "MB3753@2", + "MB3752@2", + "MB3751@2", + "MB3750@2", + "MB3721@2", + "MB3725@2", + "BG3772@2", + "BG3766@2", + "BG3765@2", + "BG3767@2", + "BG3771@2", + "BG3770@2", + "MB3772@2", + "MB3766@2", + "MB3765@2", + "MB3767@2", + "MB3771@2", + "MB3770@2", + "BG3727@2" + ], + "UC3202": [ + "BG3783@3", + "BG3784@3", + "BG3781@3", + "BG3780@3", + "BG3782@3", + "BG3816@3", + "BG3815@3", + "BG3814@3", + "BG3813@3", + "BG3812@3", + "BG3811@3", + "BG3810@3", + "BG3823@3", + "BG3822@3", + "BG3821@3", + "BG3820@3", + "BG3817@3", + "BG3824@3", + "BG3826@3", + "BG3825@3", + "BG3827@3", + "BG3830@3", + "BG3786@3", + "BG3785@3", + "MB3784@3", + "MB3780@3", + "MB3781@3", + "MB3816@3", + "MB3815@3", + "MB3814@3", + "MB3813@3", + "MB3812@3", + "MB3811@3", + "MB3810@3", + "MB3823@3", + "MB3822@3", + "MB3821@3", + "MB3820@3", + "MB3817@3", + "MB3824@3", + "MB3826@3", + "MB3825@3", + "MB3827@3", + "MB3830@3", + "MB3786@3", + "BG3787@3", + "BG3787@2" + ], + "UC2202": [ + "BG3783@2", + "BG3784@2", + "BG3781@2", + "BG3780@2", + "BG3782@2", + "BG3816@2", + "BG3815@2", + "BG3814@2", + "BG3813@2", + "BG3812@2", + "BG3811@2", + "BG3810@2", + "BG3823@2", + "BG3822@2", + "BG3821@2", + "BG3820@2", + "BG3817@2", + "BG3824@2", + "BG3826@2", + "BG3825@2", + "BG3827@2", + "BG3830@2", + "BG3786@2", + "BG3785@2", + "MB3784@2", + "MB3780@2", + "MB3781@2", + "MB3816@2", + "MB3815@2", + "MB3814@2", + "MB3813@2", + "MB3812@2", + "MB3811@2", + "MB3810@2", + "MB3823@2", + "MB3822@2", + "MB3821@2", + "MB3820@2", + "MB3817@2", + "MB3824@2", + "MB3826@2", + "MB3825@2", + "MB3827@2", + "MB3830@2", + "MB3786@2" + ], + "UC3203": [ + "BG3843@3", + "BG3844@3", + "BG3841@3", + "BG3842@3", + "BG3840@3", + "BG3870@3", + "BG3871@3", + "BG3872@3", + "BG3873@3", + "BG3874@3", + "BG3875@3", + "BG3876@3", + "BG3877@3", + "BG3880@3", + "BG3881@3", + "BG3882@3", + "BG3883@3", + "BG3884@3", + "BG3885@3", + "BG3886@3", + "BG3887@3", + "BG3890@3", + "BG3891@3", + "BG3892@3", + "BG3893@3", + "BG3894@3", + "MB3844@3", + "MB3841@3", + "MB3840@3", + "MB3870@3", + "MB3871@3", + "MB3872@3", + "MB3873@3", + "MB3874@3", + "MB3875@3", + "MB3876@3", + "MB3877@3", + "MB3880@3", + "MB3881@3", + "MB3882@3", + "MB3883@3", + "MB3884@3", + "MB3885@3", + "MB3886@3", + "MB3887@3", + "MB3890@3", + "MB3891@3", + "MB3892@3", + "MB3893@3", + "MB3894@3", + "BG3847@3", + "BG3845@3" + ], + "UC2203": [ + "BG3843@2", + "BG3844@2", + "BG3841@2", + "BG3842@2", + "BG3840@2", + "BG3870@2", + "BG3871@2", + "BG3872@2", + "BG3873@2", + "BG3874@2", + "BG3875@2", + "BG3876@2", + "BG3877@2", + "BG3880@2", + "BG3881@2", + "BG3882@2", + "BG3883@2", + "BG3884@2", + "BG3885@2", + "BG3886@2", + "BG3887@2", + "BG3890@2", + "BG3891@2", + "BG3892@2", + "BG3893@2", + "BG3894@2", + "MB3844@2", + "MB3841@2", + "MB3840@2", + "MB3870@2", + "MB3871@2", + "MB3872@2", + "MB3873@2", + "MB3874@2", + "MB3875@2", + "MB3876@2", + "MB3877@2", + "MB3880@2", + "MB3881@2", + "MB3882@2", + "MB3883@2", + "MB3884@2", + "MB3885@2", + "MB3886@2", + "MB3887@2", + "MB3890@2", + "MB3891@2", + "MB3892@2", + "MB3893@2", + "MB3894@2", + "BG3847@2", + "BG3845@2" + ], + "UC3204": [ + "BG3903@3", + "BG3904@3", + "BG3901@3", + "BG3902@3", + "BG3900@3", + "BG3915@3", + "BG3905@3", + "BG3906@3", + "BG3930@3", + "BG3931@3", + "BG3932@3", + "BG3933@3", + "BG3934@3", + "BG3935@3", + "BG3936@3", + "BG3937@3", + "BG3940@3", + "BG3941@3", + "BG3942@3", + "BG3943@3", + "BG3944@3", + "BG3913@3", + "BG3912@3", + "BG3910@3", + "BG3916@3", + "MB3904@3", + "MB3901@3", + "MB3900@3", + "MB3930@3", + "MB3931@3", + "MB3932@3", + "MB3933@3", + "MB3934@3", + "MB3935@3", + "MB3936@3", + "MB3937@3", + "MB3940@3", + "MB3941@3", + "MB3942@3", + "MB3943@3", + "MB3944@3", + "MB3912@3", + "MB3910@3", + "BG3922@3", + "BG3920@3", + "BG3921@3", + "MB3920@3", + "BG3907@3" + ], + "UC2204": [ + "BG3903@2", + "BG3904@2", + "BG3901@2", + "BG3902@2", + "BG3900@2", + "BG3905@2", + "BG3906@2", + "BG3930@2", + "BG3931@2", + "BG3932@2", + "BG3933@2", + "BG3934@2", + "BG3935@2", + "BG3936@2", + "BG3937@2", + "BG3940@2", + "BG3941@2", + "BG3942@2", + "BG3943@2", + "BG3944@2", + "BG3912@2", + "BG3910@2", + "MB3904@2", + "MB3901@2", + "MB3900@2", + "MB3905@2", + "MB3930@2", + "MB3931@2", + "MB3932@2", + "MB3933@2", + "MB3934@2", + "MB3935@2", + "MB3936@2", + "MB3937@2", + "MB3940@2", + "MB3941@2", + "MB3942@2", + "MB3943@2", + "MB3944@2", + "BG3911@2", + "MB3906@2", + "BG3907@2" + ], + "UC3205": [ + "BG4012@3", + "BG4003@3", + "BG4002@3", + "BG4001@3", + "BG4000@3", + "BG3997@3", + "BG4006@3", + "BG4005@3", + "BG4004@3", + "BG4007@3", + "BG4011@3", + "BG4010@3", + "BG3996@3", + "BG3995@3", + "BG3994@3", + "BG3993@3", + "BG3992@3", + "BG3991@3", + "BG3990@3", + "BG3960@3", + "BG3962@3", + "BG3963@3", + "BG3964@3", + "BG3961@3", + "BG3965@3", + "MB4012@3", + "MB4003@3", + "MB4002@3", + "MB4001@3", + "MB4000@3", + "MB3997@3", + "MB4006@3", + "MB4005@3", + "MB4004@3", + "MB4007@3", + "MB4011@3", + "MB4010@3", + "MB3996@3", + "MB3995@3", + "MB3994@3", + "MB3993@3", + "MB3992@3", + "MB3991@3", + "MB3990@3", + "MB3960@3", + "MB3961@3", + "MB3964@3", + "MB3965@3", + "BG3967@3" + ], + "UC2205": [ + "BG4012@2", + "BG4003@2", + "BG4002@2", + "BG4001@2", + "BG4000@2", + "BG3997@2", + "BG4006@2", + "BG4005@2", + "BG4004@2", + "BG4007@2", + "BG4011@2", + "BG4010@2", + "BG3996@2", + "BG3995@2", + "BG3994@2", + "BG3993@2", + "BG3992@2", + "BG3991@2", + "BG3990@2", + "BG3960@2", + "BG3962@2", + "BG3963@2", + "BG3964@2", + "BG3961@2", + "BG3965@2", + "MB4012@2", + "MB4003@2", + "MB4002@2", + "MB4001@2", + "MB4000@2", + "MB3997@2", + "MB4006@2", + "MB4005@2", + "MB4004@2", + "MB4007@2", + "MB4011@2", + "MB4010@2", + "MB3996@2", + "MB3995@2", + "MB3994@2", + "MB3993@2", + "MB3992@2", + "MB3991@2", + "MB3990@2", + "MB3960@2", + "MB3961@2", + "MB3964@2", + "MB3965@2", + "BG3967@2" + ], + "UC3206": [ + "BG4056@3", + "BG4055@3", + "BG4054@3", + "BG4053@3", + "BG4052@3", + "BG4051@3", + "BG4050@3", + "BG4020@3", + "BG4022@3", + "BG4023@3", + "BG4024@3", + "BG4021@3", + "BG4063@3", + "BG4062@3", + "BG4061@3", + "BG4060@3", + "BG4057@3", + "BG4064@3", + "BG4066@3", + "BG4065@3", + "BG4067@3", + "BG4070@3", + "BG4026@3", + "BG4025@3", + "MB4056@3", + "MB4055@3", + "MB4054@3", + "MB4053@3", + "MB4052@3", + "MB4051@3", + "MB4050@3", + "MB4020@3", + "MB4021@3", + "MB4024@3", + "MB4063@3", + "MB4062@3", + "MB4061@3", + "MB4060@3", + "MB4057@3", + "MB4064@3", + "MB4066@3", + "MB4065@3", + "MB4067@3", + "MB4070@3", + "MB4026@3", + "BG4027@3" + ], + "UC2206": [ + "BG4056@2", + "BG4055@2", + "BG4054@2", + "BG4053@2", + "BG4052@2", + "BG4051@2", + "BG4050@2", + "BG4020@2", + "BG4022@2", + "BG4023@2", + "BG4024@2", + "BG4021@2", + "BG4063@2", + "BG4062@2", + "BG4061@2", + "BG4060@2", + "BG4057@2", + "BG4064@2", + "BG4066@2", + "BG4065@2", + "BG4067@2", + "BG4070@2", + "BG4026@2", + "BG4025@2", + "MB4056@2", + "MB4055@2", + "MB4054@2", + "MB4053@2", + "MB4052@2", + "MB4051@2", + "MB4050@2", + "MB4020@2", + "MB4021@2", + "MB4024@2", + "MB4063@2", + "MB4062@2", + "MB4061@2", + "MB4060@2", + "MB4057@2", + "MB4064@2", + "MB4066@2", + "MB4065@2", + "MB4067@2", + "MB4070@2", + "MB4026@2", + "BG4027@2" + ], + "UC3207": [ + "BG4083@3", + "BG4084@3", + "BG4081@3", + "BG4080@3", + "BG4082@3", + "BG4110@3", + "BG4111@3", + "BG4112@3", + "BG4113@3", + "BG4114@3", + "BG4115@3", + "BG4116@3", + "BG4117@3", + "BG4120@3", + "BG4121@3", + "BG4122@3", + "BG4123@3", + "BG4124@3", + "BG4125@3", + "BG4126@3", + "BG4127@3", + "BG4130@3", + "BG4131@3", + "BG4132@3", + "BG4133@3", + "BG4134@3", + "BG4090@3", + "BG4085@3", + "BG4086@3", + "BG4091@3", + "BG4092@3", + "BG4093@3", + "BG4094@3", + "MB4084@3", + "MB4080@3", + "MB4081@3", + "MB4110@3", + "MB4111@3", + "MB4112@3", + "MB4113@3", + "MB4114@3", + "MB4115@3", + "MB4116@3", + "MB4117@3", + "MB4120@3", + "MB4121@3", + "MB4122@3", + "MB4123@3", + "MB4124@3", + "MB4125@3", + "MB4126@3", + "MB4127@3", + "MB4130@3", + "MB4131@3", + "MB4132@3", + "MB4133@3", + "MB4134@3", + "MB4085@3", + "MB4091@3", + "BG4097@3", + "BG4095@3", + "BG4096@3", + "MB4095@3", + "BG4087@3" + ], + "UC2207": [ + "BG4083@2", + "BG4084@2", + "BG4081@2", + "BG4080@2", + "BG4082@2", + "BG4110@2", + "BG4111@2", + "BG4112@2", + "BG4113@2", + "BG4114@2", + "BG4115@2", + "BG4116@2", + "BG4117@2", + "BG4120@2", + "BG4121@2", + "BG4122@2", + "BG4123@2", + "BG4124@2", + "BG4125@2", + "BG4126@2", + "BG4127@2", + "BG4130@2", + "BG4131@2", + "BG4132@2", + "BG4133@2", + "BG4134@2", + "BG4090@2", + "BG4085@2", + "BG4086@2", + "BG4091@2", + "MB4084@2", + "MB4080@2", + "MB4081@2", + "MB4110@2", + "MB4111@2", + "MB4112@2", + "MB4113@2", + "MB4114@2", + "MB4115@2", + "MB4116@2", + "MB4117@2", + "MB4120@2", + "MB4121@2", + "MB4122@2", + "MB4123@2", + "MB4124@2", + "MB4125@2", + "MB4126@2", + "MB4127@2", + "MB4130@2", + "MB4131@2", + "MB4132@2", + "MB4133@2", + "MB4134@2", + "MB4085@2", + "MB4086@2", + "BG4087@2" + ], + "UC3208": [ + "BG4143@3", + "BG4144@3", + "BG4141@3", + "BG4140@3", + "BG4142@3", + "BG4170@3", + "BG4171@3", + "BG4172@3", + "BG4173@3", + "BG4174@3", + "BG4175@3", + "BG4176@3", + "BG4177@3", + "BG4180@3", + "BG4181@3", + "BG4182@3", + "BG4183@3", + "BG4184@3", + "BG4145@3", + "BG4185@3", + "BG4186@3", + "BG4152@3", + "BG4150@3", + "MB4144@3", + "MB4140@3", + "MB4141@3", + "MB4170@3", + "MB4171@3", + "MB4172@3", + "MB4173@3", + "MB4174@3", + "MB4175@3", + "MB4176@3", + "MB4177@3", + "MB4180@3", + "MB4181@3", + "MB4182@3", + "MB4183@3", + "MB4184@3", + "MB4145@3", + "MB4185@3", + "MB4186@3", + "MB4146@3", + "BG4147@3" + ], + "UC2208": [ + "BG4143@2", + "BG4144@2", + "BG4141@2", + "BG4140@2", + "BG4142@2", + "BG4170@2", + "BG4171@2", + "BG4172@2", + "BG4173@2", + "BG4174@2", + "BG4175@2", + "BG4176@2", + "BG4177@2", + "BG4180@2", + "BG4181@2", + "BG4182@2", + "BG4183@2", + "BG4184@2", + "BG4150@2", + "MB4144@2", + "MB4140@2", + "MB4141@2", + "MB4170@2", + "MB4171@2", + "MB4172@2", + "MB4173@2", + "MB4174@2", + "MB4175@2", + "MB4176@2", + "MB4177@2", + "MB4180@2", + "MB4181@2", + "MB4182@2", + "MB4183@2", + "MB4184@2", + "BG4151@2", + "BG4147@2" + ], + "UC033": [ + "MA0262@3", + "MA0260@3", + "MA0263@3", + "MA0261@3", + "MA0264@3", + "MA0265@3", + "BP0227@3" + ], + "UC023": [ + "MA0262@2", + "MA0260@2", + "MA0263@2", + "MA0261@2", + "MA0264@2", + "MA0265@2", + "MA0266@2", + "BP0227@2" + ], + "UC3301": [ + "BG4200@3", + "BG4204@3", + "BG4205@3", + "BG4207@3", + "BG4210@3", + "BG4211@3", + "BG4212@3", + "BG4201@3", + "BG4202@3", + "BG4252@3", + "BG4251@3", + "BG4250@3", + "BG4247@3", + "BG4246@3", + "BG4245@3", + "BG4244@3", + "BG4243@3", + "BG4242@3", + "BG4241@3", + "BG4240@3", + "BG4237@3", + "BG4236@3", + "BG4235@3", + "BG4234@3", + "BG4233@3", + "BG4232@3", + "BG4231@3", + "BG4230@3", + "BG4206@3", + "MB4245@3", + "MB4246@3", + "MB4247@3", + "MB4250@3", + "MB4251@3", + "MB4252@3", + "MB4230@3", + "MB4231@3", + "MB4232@3", + "MB4233@3", + "MB4234@3", + "MB4235@3", + "MB4236@3", + "MB4200@3", + "MB4204@3", + "MB4244@3", + "MB4243@3", + "MB4242@3", + "MB4241@3", + "MB4240@3", + "MB4237@3", + "BG4203@3" + ], + "UC2301": [ + "BG4200@2", + "BG4204@2", + "BG4205@2", + "BG4207@2", + "BG4210@2", + "BG4211@2", + "BG4212@2", + "BG4201@2", + "BG4202@2", + "BG4252@2", + "BG4251@2", + "BG4250@2", + "BG4247@2", + "BG4246@2", + "BG4245@2", + "BG4244@2", + "BG4243@2", + "BG4242@2", + "BG4241@2", + "BG4240@2", + "BG4237@2", + "BG4236@2", + "BG4235@2", + "BG4234@2", + "BG4233@2", + "BG4232@2", + "BG4231@2", + "BG4230@2", + "BG4206@2", + "MB4245@2", + "MB4246@2", + "MB4247@2", + "MB4250@2", + "MB4251@2", + "MB4252@2", + "MB4230@2", + "MB4231@2", + "MB4232@2", + "MB4233@2", + "MB4234@2", + "MB4235@2", + "MB4236@2", + "MB4200@2", + "MB4204@2", + "MB4244@2", + "MB4243@2", + "MB4242@2", + "MB4241@2", + "MB4240@2", + "MB4237@2", + "BG4203@2" + ], + "UC3302": [ + "BG4260@3", + "BG4264@3", + "BG4265@3", + "BG4261@3", + "BG4262@3", + "BG4266@3", + "BG4296@3", + "BG4295@3", + "BG4294@3", + "BG4293@3", + "BG4292@3", + "BG4291@3", + "BG4290@3", + "BG4304@3", + "BG4303@3", + "BG4302@3", + "BG4301@3", + "BG4300@3", + "BG4297@3", + "BG4310@3", + "BG4307@3", + "BG4306@3", + "BG4305@3", + "BG4267@3", + "BG4270@3", + "BG4271@3", + "BG4272@3", + "MB4260@3", + "MB4264@3", + "MB4305@3", + "MB4306@3", + "MB4307@3", + "MB4310@3", + "MB4290@3", + "MB4291@3", + "MB4292@3", + "MB4293@3", + "MB4294@3", + "MB4295@3", + "MB4296@3", + "MB4304@3", + "MB4303@3", + "MB4302@3", + "MB4301@3", + "MB4300@3", + "MB4297@3", + "BG4263@3", + "BG4273@3" + ], + "UC2302": [ + "BG4260@2", + "BG4264@2", + "BG4265@2", + "BG4261@2", + "BG4262@2", + "BG4266@2", + "BG4296@2", + "BG4295@2", + "BG4294@2", + "BG4293@2", + "BG4292@2", + "BG4291@2", + "BG4290@2", + "BG4304@2", + "BG4303@2", + "BG4302@2", + "BG4301@2", + "BG4300@2", + "BG4297@2", + "BG4310@2", + "BG4307@2", + "BG4306@2", + "BG4305@2", + "BG4267@2", + "BG4270@2", + "BG4271@2", + "BG4272@2", + "MB4260@2", + "MB4264@2", + "MB4305@2", + "MB4306@2", + "MB4307@2", + "MB4310@2", + "MB4290@2", + "MB4291@2", + "MB4292@2", + "MB4293@2", + "MB4294@2", + "MB4295@2", + "MB4296@2", + "MB4304@2", + "MB4303@2", + "MB4302@2", + "MB4301@2", + "MB4300@2", + "MB4297@2", + "BG4263@2", + "MB4261@2", + "BG4273@2" + ], + "UC3303": [ + "BG4324@3", + "BG4325@3", + "BG4326@3", + "BG4323@3", + "BG4322@3", + "BG4321@3", + "BG4320@3", + "BG4337@3", + "BG4350@3", + "BG4351@3", + "BG4352@3", + "BG4353@3", + "BG4354@3", + "BG4355@3", + "BG4356@3", + "BG4357@3", + "BG4360@3", + "BG4361@3", + "BG4362@3", + "BG4363@3", + "BG4364@3", + "BG4365@3", + "BG4366@3", + "BG4367@3", + "BG4370@3", + "BG4371@3", + "BG4372@3", + "BG4374@3", + "BG4373@3", + "BG4332@3", + "BG4331@3", + "BG4330@3", + "BG4327@3", + "BG4335@3", + "BG4334@3", + "BG4333@3", + "MB4324@3", + "MB4320@3", + "MB4337@3", + "MB4350@3", + "MB4351@3", + "MB4352@3", + "MB4353@3", + "MB4354@3", + "MB4355@3", + "MB4356@3", + "MB4357@3", + "MB4360@3", + "MB4361@3", + "MB4362@3", + "MB4363@3", + "MB4364@3", + "MB4365@3", + "MB4366@3", + "MB4367@3", + "MB4370@3", + "MB4371@3", + "MB4372@3", + "MB4373@3", + "MB4374@3", + "MB4334@3", + "MB4335@3", + "BG4336@3", + "MB4261@3", + "BG4375@3" + ], + "UC2303": [ + "BG4324@2", + "BG4325@2", + "BG4326@2", + "BG4323@2", + "BG4322@2", + "BG4321@2", + "BG4320@2", + "BG4337@2", + "BG4350@2", + "BG4351@2", + "BG4352@2", + "BG4353@2", + "BG4354@2", + "BG4355@2", + "BG4356@2", + "BG4357@2", + "BG4360@2", + "BG4361@2", + "BG4362@2", + "BG4363@2", + "BG4364@2", + "BG4365@2", + "BG4366@2", + "BG4367@2", + "BG4370@2", + "BG4371@2", + "BG4372@2", + "BG4374@2", + "BG4373@2", + "BG4332@2", + "BG4331@2", + "BG4330@2", + "BG4327@2", + "BG4335@2", + "BG4334@2", + "BG4333@2", + "BG4343@2", + "BG4342@2", + "BG4344@2", + "MB4324@2", + "MB4320@2", + "MB4337@2", + "MB4350@2", + "MB4351@2", + "MB4352@2", + "MB4353@2", + "MB4354@2", + "MB4355@2", + "MB4356@2", + "MB4357@2", + "MB4360@2", + "MB4361@2", + "MB4362@2", + "MB4363@2", + "MB4364@2", + "MB4365@2", + "MB4366@2", + "MB4367@2", + "MB4370@2", + "MB4371@2", + "MB4372@2", + "MB4373@2", + "MB4374@2", + "MB4334@2", + "MB4342@2", + "BG4340@2", + "BG4336@2", + "BG4341@2" + ], + "UC3304": [ + "BG4384@3", + "BG4385@3", + "BG4386@3", + "BG4383@3", + "BG4382@3", + "BG4381@3", + "BG4380@3", + "BG4410@3", + "BG4411@3", + "BG4412@3", + "BG4413@3", + "BG4414@3", + "BG4415@3", + "BG4416@3", + "BG4417@3", + "BG4420@3", + "BG4390@3", + "BG4387@3", + "BG4421@3", + "BG4422@3", + "BG4423@3", + "BG4424@3", + "BG4391@3", + "BG4425@3", + "BG4426@3", + "BG4392@3", + "BG4395@3", + "BG4396@3", + "MB4384@3", + "MB4380@3", + "MB4410@3", + "MB4411@3", + "MB4412@3", + "MB4413@3", + "MB4414@3", + "MB4415@3", + "MB4416@3", + "MB4417@3", + "MB4420@3", + "MB4421@3", + "MB4422@3", + "MB4423@3", + "MB4424@3", + "MB4425@3", + "MB4426@3", + "MB4395@3", + "MB4392@3" + ], + "UC2304": [ + "BG4384@2", + "BG4385@2", + "BG4386@2", + "BG4383@2", + "BG4382@2", + "BG4381@2", + "BG4380@2", + "BG4410@2", + "BG4411@2", + "BG4412@2", + "BG4413@2", + "BG4414@2", + "BG4415@2", + "BG4416@2", + "BG4417@2", + "BG4420@2", + "BG4390@2", + "BG4387@2", + "BG4421@2", + "BG4422@2", + "BG4423@2", + "BG4424@2", + "BG4391@2", + "MB4384@2", + "MB4380@2", + "MB4410@2", + "MB4411@2", + "MB4412@2", + "MB4413@2", + "MB4414@2", + "MB4415@2", + "MB4416@2", + "MB4417@2", + "MB4420@2", + "MB4421@2", + "MB4422@2", + "MB4423@2", + "MB4424@2" + ], + "UC0309": [ + "BG4444@3", + "BG4440@3", + "BG4441@3", + "BG4442@3", + "MB4444@3", + "MB4440@3", + "BG4451@3", + "BG4450@3", + "BG4452@3", + "MB4450@3" + ], + "UC0210": [ + "BG4541@2", + "BG4540@2", + "BG4542@2", + "BG4544@2", + "BG4543@2", + "BG4545@2", + "BG4500@2", + "BG4507@2", + "BG4505@2", + "MB4540@2", + "MB4543@2", + "MB4500@2", + "MB4503@2", + "MB4505@2", + "BG4525@2", + "BG4524@2", + "BG4521@2", + "BG4520@2", + "BG4526@2", + "BG4512@2", + "BG4514@2", + "BG4530@2", + "MB4504@2", + "BG4532@2", + "BG4537@2", + "BG4535@2", + "BG4536@2", + "BG4522@2", + "BG4510@2", + "MB4526@2", + "MB4512@2", + "MB4530@2", + "MB4535@2", + "MB4522@2", + "BG4502@2" + ], + "UC0310": [ + "BG4500@3", + "BG4503@3", + "BG4504@3", + "BG4507@3", + "BG4505@3", + "MB4500@3", + "MB4503@3", + "MB4505@3" + ], + "UC0111": [ + "BG0340@1", + "BG0341@1", + "MA0320@1", + "MA0380@1", + "BG0286@1", + "BG0343@1", + "MB0340@1", + "MB0343@1", + "MA0321@1", + "MB0342@1", + "MB0344@1", + "BG0344@1", + "BG0345@1", + "BG4741@1", + "BG4821@1", + "BG0346@1", + "BG0342@1", + "BG0347@1", + "MB0385@1" + ], + "UC0110": [ + "BG0280@1", + "MA0280@1", + "MA0282@1", + "BG0284@1", + "BG0283@1", + "MA0283@1", + "BG0285@1", + "BG4740@1", + "MA0284@1", + "BG0282@1", + "BG0287@1", + "MB0325@1" + ], + "UC031": [ + "BP0107@3" + ] + }, + "distributors": { + "UC0312": [ + 267198.4, + 448693.1 + ], + "UC031": [ + 244820.1, + 434510.6 + ], + "UC1102": [ + 355009.7, + 453798.1 + ], + "UC1103": [ + 328148.4, + 449006.4 + ], + "UC1101": [ + 337890.0, + 455705.7 + ], + "UC0309": [ + 244807.5, + 452088.0 + ], + "UC0311": [ + 250903.7, + 443862.1 + ], + "UC0303": [ + 215779.7, + 440918.3 + ], + "UC0307": [ + 215763.0, + 438881.1 + ], + "UC0304": [ + 233071.1, + 440313.2 + ], + "UC0308": [ + 233064.3, + 438890.3 + ], + "UC0302": [ + 197851.1, + 440294.1 + ], + "UC0306": [ + 197856.0, + 438889.2 + ], + "UC0301": [ + 178562.5, + 440293.4 + ], + "UC0305": [ + 178564.7, + 438876.1 + ], + "UC3203": [ + 215786.6, + 420807.0 + ], + "UC3207": [ + 217576.0, + 418679.3 + ], + "UC3202": [ + 197862.9, + 420806.7 + ], + "UC3206": [ + 197860.1, + 418681.0 + ], + "UC3201": [ + 178560.5, + 420802.5 + ], + "UC3205": [ + 178562.5, + 418683.9 + ], + "UC0310": [ + 244820.1, + 434510.6 + ], + "UC3208": [ + 233067.7, + 418688.0 + ], + "UC3204": [ + 233067.7, + 420819.3 + ], + "UC0204": [ + 233071.1, + 290308.7 + ], + "UC0209": [ + 244807.5, + 302308.5 + ], + "UC021": [ + 250903.7, + 293660.9 + ], + "UC0210": [ + 244820.1, + 284510.6 + ], + "UC0211": [ + 250903.7, + 293660.9 + ], + "UC0208": [ + 233062.1, + 288889.6 + ], + "UC0203": [ + 215783.5, + 290923.9 + ], + "UC0207": [ + 215772.7, + 288888.7 + ], + "UC0202": [ + 197832.3, + 290286.1 + ], + "UC0206": [ + 197837.2, + 288882.9 + ], + "UC0201": [ + 178559.2, + 290288.9 + ], + "UC0205": [ + 178561.4, + 288884.9 + ], + "UC2201": [ + 178556.2, + 270807.2 + ], + "UC2205": [ + 178558.2, + 268685.3 + ], + "UC2202": [ + 197868.2, + 270810.0 + ], + "UC2206": [ + 197865.4, + 268686.6 + ], + "UC2203": [ + 215797.3, + 270800.1 + ], + "UC2207": [ + 217586.6, + 268681.3 + ], + "UC2204": [ + 233067.7, + 270814.4 + ], + "UC2208": [ + 233067.7, + 268678.9 + ], + "UC011": [ + 338702.8, + 167125.6 + ], + "UC0110": [ + 332702.8, + 167125.6 + ], + "UC0111": [ + 338702.8, + 167125.6 + ], + "UC0502": [ + 223991.4, + 152057.8 + ], + "UC0501": [ + 220290.2, + 152004.7 + ], + "UC0503": [ + 228958.7, + 152034.8 + ], + "UC0504": [ + 237626.0, + 152689.9 + ], + "UC0402": [ + 351826.2, + 729244.3 + ], + "UC0403": [ + 351834.1, + 741234.5 + ], + "UC0401": [ + 372304.4, + 747621.0 + ], + "UC0404": [ + 351872.4, + 750759.4 + ], + "UC0102": [ + 335868.6, + 152071.4 + ], + "UC0101": [ + 335975.5, + 165606.2 + ], + "UC2102": [ + 197812.4, + 310219.6 + ], + "UC2103": [ + 215673.5, + 309832.5 + ], + "UC2104": [ + 233103.9, + 310246.0 + ], + "UC2301": [ + 179722.2, + 247421.3 + ], + "UC2302": [ + 198501.9, + 247433.8 + ], + "UC2303": [ + 215783.1, + 247382.3 + ], + "UC2304": [ + 233067.4, + 247404.7 + ], + "UC2101": [ + 179743.1, + 310271.6 + ], + "UC3102": [ + 198515.2, + 460357.9 + ], + "UC3103": [ + 215801.2, + 460322.8 + ], + "UC3104": [ + 233094.9, + 460373.3 + ], + "UC3301": [ + 179732.1, + 397433.3 + ], + "UC3302": [ + 198501.0, + 397437.4 + ], + "UC3303": [ + 215420.8, + 397634.4 + ], + "UC3304": [ + 232707.2, + 397629.7 + ], + "UC3101": [ + 179717.2, + 460364.1 + ] + }, + "tunnels": {}, + "racks": { + "Rack_1": [ + [ + 359970.0, + 752575.8, + 0.0 + ], + [ + 360884.9, + 752575.8, + 0.0 + ], + [ + 360884.9, + 752575.8, + 0.0 + ], + [ + 360884.9, + 752575.8, + 0.0 + ], + [ + 360884.9, + 752575.8, + 0.0 + ], + [ + 360884.9, + 752575.8, + 0.0 + ], + [ + 360884.9, + 752575.8, + 0.0 + ] + ], + "Rack_2": [ + [ + 251292.9, + 133440.0, + 10196.3 + ], + [ + 252292.9, + 133440.0, + 10196.3 + ] + ], + "Rack_3": [ + [ + 215970.0, + 151230.0, + 0 + ], + [ + 242148.5, + 151230.0, + 0 + ] + ], + "Rack_4": [ + [ + 216514.5, + 156495.3, + 0 + ], + [ + 216514.5, + 155290.8, + 0 + ] + ], + "Rack_5": [ + [ + 216714.5, + 156495.3, + 0 + ], + [ + 216714.5, + 155290.8, + 0 + ] + ], + "Rack_6": [ + [ + 216417.0, + 155191.8, + 0 + ], + [ + 219876.5, + 155191.8, + 0 + ] + ], + "Rack_7": [ + [ + 219980.1, + 157550.0, + 0 + ], + [ + 219980.1, + 151330.6, + 0 + ] + ], + "Rack_8": [ + [ + 222586.8, + 156780.0, + 0 + ], + [ + 222586.8, + 151330.6, + 0 + ] + ], + "Rack_9": [ + [ + 226827.5, + 156780.0, + 0 + ], + [ + 226827.5, + 151330.6, + 0 + ] + ], + "Rack_10": [ + [ + 231106.6, + 156780.0, + 0 + ], + [ + 231106.6, + 151330.6, + 0 + ] + ], + "Rack_11": [ + [ + 235677.5, + 156780.0, + 0 + ], + [ + 235677.5, + 151330.6, + 0 + ] + ], + "Rack_12": [ + [ + 239257.3, + 159152.0, + 0 + ], + [ + 239257.3, + 151330.6, + 0 + ] + ], + "Rack_13": [ + [ + 218456.6, + 155090.0, + 0 + ], + [ + 218456.6, + 151330.6, + 0 + ] + ], + "Rack_14": [ + [ + 216800.0, + 151120.0, + 0 + ], + [ + 216800.0, + 150330.4, + 0 + ] + ], + "Rack_15": [ + [ + 228177.4, + 151120.0, + 0 + ], + [ + 228178.6, + 150103.0, + 0 + ] + ], + "Rack_16": [ + [ + 237087.8, + 151120.0, + 0 + ], + [ + 237087.8, + 150248.3, + 0 + ] + ], + "Rack_17": [ + [ + 229030.9, + 153020.1, + 0 + ], + [ + 229030.9, + 151340.5, + 0 + ] + ], + "Rack_18": [ + [ + 242163.6, + 150777.4, + -0.0 + ], + [ + 242163.6, + 151332.3, + -0.0 + ] + ], + "Rack_19": [ + [ + 225890.2, + 151130.0, + 2167.0 + ], + [ + 225890.2, + 149060.2, + 2167.0 + ] + ], + "Rack_20": [ + [ + 223019.8, + 151127.0, + 2167.0 + ], + [ + 223019.8, + 149107.2, + 2167.0 + ] + ], + "Rack_21": [ + [ + 357310.8, + 750364.5, + 58204.5 + ], + [ + 357300.8, + 750364.5, + 58204.5 + ], + [ + 357250.8, + 750364.5, + 58204.5 + ], + [ + 357240.8, + 750364.5, + 58204.5 + ] + ], + "Rack_22": [ + [ + 357407.3, + 753098.0, + 0 + ], + [ + 357407.3, + 753098.0, + 0 + ], + [ + 357407.3, + 722385.2, + 0 + ] + ], + "Rack_23": [ + [ + 357300.8, + 728845.8, + 58204.5 + ], + [ + 349994.6, + 728845.8, + 58204.5 + ] + ], + "Rack_24": [ + [ + 357305.3, + 740842.2, + 58201.3 + ], + [ + 349899.1, + 740842.2, + 58201.3 + ] + ], + "Rack_25": [ + [ + 357300.8, + 750364.5, + 58204.5 + ], + [ + 349994.6, + 750364.5, + 58204.5 + ] + ], + "Rack_26": [ + [ + 357407.3, + 722484.0, + 0 + ], + [ + 360035.1, + 722484.0, + 0 + ], + [ + 360035.1, + 720394.0, + 0 + ] + ], + "Rack_27": [ + [ + 360518.0, + 751396.1, + 0 + ], + [ + 360518.0, + 752578.0, + 0 + ], + [ + 360262.9, + 752578.0, + 0 + ] + ], + "Rack_28": [ + [ + 365887.7, + 748199.9, + -19506.1 + ], + [ + 364425.7, + 748199.9, + -19506.1 + ], + [ + 362649.0, + 751294.3, + -19506.1 + ], + [ + 360419.3, + 751294.3, + -19506.1 + ] + ], + "Rack_29": [ + [ + 361076.6, + 751397.4, + -0.0 + ], + [ + 361076.6, + 751997.4, + -0.0 + ] + ], + "Rack_30": [ + [ + 359860.0, + 720400.0, + 0 + ], + [ + 359860.0, + 722381.6, + 0 + ] + ], + "Rack_31": [ + [ + 357502.7, + 744135.1, + 0.0 + ], + [ + 359671.4, + 744135.1, + 0.0 + ] + ], + "Rack_32": [ + [ + 351427.8, + 728950.0, + 0 + ], + [ + 351427.8, + 729465.0, + 0 + ] + ], + "Rack_33": [ + [ + 357502.7, + 752579.1, + 0.0 + ], + [ + 359841.6, + 752579.1, + 0.0 + ], + [ + 359841.6, + 751282.3, + 0.0 + ] + ], + "Rack_34": [ + [ + 365887.7, + 748199.9, + -19506.1 + ], + [ + 379287.7, + 748199.9, + -19506.1 + ] + ], + "Rack_35": [ + [ + 351427.8, + 740942.7, + 0 + ], + [ + 351427.8, + 741457.7, + 0 + ] + ], + "Rack_36": [ + [ + 351427.8, + 750465.0, + 0 + ], + [ + 351427.8, + 750980.0, + 0 + ] + ], + "Rack_37": [ + [ + 357315.3, + 740842.2, + 58201.3 + ], + [ + 357305.3, + 740842.2, + 58201.3 + ], + [ + 357255.3, + 740842.2, + 58201.3 + ], + [ + 357245.3, + 740842.2, + 58201.3 + ] + ], + "Rack_38": [ + [ + 357310.8, + 728845.8, + 58204.5 + ], + [ + 357300.8, + 728845.8, + 58204.5 + ], + [ + 357250.8, + 728845.8, + 58204.5 + ], + [ + 357240.8, + 728845.8, + 58204.5 + ] + ], + "Rack_39": [ + [ + 361076.6, + 751387.4, + -0.0 + ], + [ + 361076.6, + 751397.4, + -0.0 + ], + [ + 361076.6, + 751447.4, + -0.0 + ], + [ + 361076.6, + 751457.4, + -0.0 + ] + ], + "Rack_40": [ + [ + 351427.8, + 750455.0, + 0 + ], + [ + 351427.8, + 750465.0, + 0 + ], + [ + 351427.8, + 750515.0, + 0 + ], + [ + 351427.8, + 750525.0, + 0 + ] + ], + "Rack_41": [ + [ + 351427.8, + 740932.7, + 0 + ], + [ + 351427.8, + 740942.7, + 0 + ], + [ + 351427.8, + 740992.7, + 0 + ], + [ + 351427.8, + 741002.7, + 0 + ] + ], + "Rack_42": [ + [ + 351427.8, + 728940.0, + 0 + ], + [ + 351427.8, + 728950.0, + 0 + ], + [ + 351427.8, + 729000.0, + 0 + ], + [ + 351427.8, + 729010.0, + 0 + ] + ], + "Rack_43": [ + [ + 372285.0, + 748100.0, + 0 + ], + [ + 372285.0, + 747883.8, + 0 + ] + ], + "Rack_44": [ + [ + 379390.0, + 753429.9, + -19506.1 + ], + [ + 379390.0, + 748099.9, + -19506.1 + ] + ], + "Rack_45": [ + [ + 239162.2, + 159051.8, + 0 + ], + [ + 244564.9, + 159051.8, + 0 + ] + ], + "Rack_46": [ + [ + 242526.5, + 152253.3, + 4714.0 + ], + [ + 242526.5, + 159053.3, + 4714.0 + ] + ], + "Rack_47": [ + [ + 224678.9, + 151130.0, + 2167.0 + ], + [ + 224678.9, + 148570.2, + 2167.0 + ] + ] + }, + "not_found": { + "missing_distributors": [ + "U0312", + "UH03", + "UH02", + "UH01", + "UH04", + "UH05", + "UC032", + "UC022", + "UC033", + "UC023" + ], + "missing_sensors": [], + "missing_attributes": { + "MA0320@1": "Ungültiger Pfad in Kennzeichnung: =A01+UC0110KF1DQ3: +, - oder = fehlen an entsprechender Stelle", + "BG0286@1": "Ungültiger Pfad in Kennzeichnung: =A01+UC0110KF1DI1: +, - oder = fehlen an entsprechender Stelle", + "MA0321@1": "Ungültiger Pfad in Kennzeichnung: =A01+UC0110KF1DQ3: +, - oder = fehlen an entsprechender Stelle", + "BX3100": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3101": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3102": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0301": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0302": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0303": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0304": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0307": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0305": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0306": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0308": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3134": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3135": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3136": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3106": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3109": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3108": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3113": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3112": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3114": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3111": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3110": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3122": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3123": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3124": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3125": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3126": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3127": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3128": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3129": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3137": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3138": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3139": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3140": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3105": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2109": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3141": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3104": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3103": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3121": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3115": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3120": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3133": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3132": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3131": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3107": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2104": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2106": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2105": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2113": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2112": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2114": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0219": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2101": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2111": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2102": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0201": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0202": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0203": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0207": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0205": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX0206": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2202": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2203": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2204": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2206": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2208": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2207": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2107": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2122": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2123": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2121": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2124": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2125": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2126": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2127": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2128": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2129": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2135": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2136": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2137": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2138": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2131": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2132": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2133": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2130": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2134": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2103": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "MA0381": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BX1105": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG0322": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG0323": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX1103": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG4820": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG0051": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG0050": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG0382": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG0383": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "MB3243": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BX5101": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5113": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5100": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5106": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5104": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5102": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5103": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5105": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5107": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5108": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5109": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5110": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5111": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX5112": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX4101": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX4102": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX4103": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX4104": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX4105": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX4107": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX4106": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX4100": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX1100": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX1101": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX1104": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX1106": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX1102": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX3300": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG3265": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BX1107": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG3297": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BX1108": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG4457": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG4456": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "MB4456": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG4345": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2115": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2302": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2303": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2304": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BX2301": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "MA0142": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG3275": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG3156": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG3300": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG3342": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG3347": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG3426": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG3636": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG3906": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG3432": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG3435": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG4440": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG4441": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG4443": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG4500": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG4503": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG4504": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "MB4440": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG4454": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG3440": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG3911": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG4510": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG0284": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "MB3246": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG3787": "Nur ein Block und/oder fehlende Attribute: dict_keys(['A', 'B', 'C', 'ARTINR', 'BESCHR', 'MENGE', 'POSITION', 'GRUPPE', 'ETIKETTE', 'AUFLOESE', 'pos'])", + "BG3727": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG3437": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])", + "BG4375": "Nur ein Block und/oder fehlende Attribute: dict_keys(['IO', 'ID', 'VERW', 'BEZEICHNUNG', 'KENNZEICHNUNG', 'TEXT-D', 'TEXT-E', 'TEXT-ES', 'TEXT-F', 'SPS', 'pos'])" + } + }, + "double_ids": {} +} \ No newline at end of file diff --git a/data/connect.ini b/data/connect.ini new file mode 100644 index 0000000..5b628db --- /dev/null +++ b/data/connect.ini @@ -0,0 +1,646 @@ +; ============================================================ +; connect.ini — Routing / Zusammenhalt der TROs (hmf-connect-v1) +; Quelle: doc/TRO_Graph_UH01-UH05.dot (inhaltsgleich zu connect.json) +; +; [UHxx.nodes] TRO = | +; [UHxx.connections] cNNN = -> | | +; kind: normal | dir2 | dir3 | bypass | finger +; (dir2/dir3 = Weichenausgang, Richtung aus FC_Direction) +; [UHxx.externals] eNNN = EXTERN -> | (Zulauf) +; eNNN = -> EXTERN | (Ablauf) +; JamArea JAxxxx_y entspricht "DB_JamAreaxxxx".stJamxxxx_y +; ============================================================ + +[UH01.nodes] +TRO100 = 1Sep | TRO 100 (1Sep) +TRO101 = EmptyCarrBuffer | TRO101 (Empty Buffer rechts) +TRO101_IN = 1Sep | TRO 101_IN(1Sep) +TRO102 = EmptyCarrBuffer | TRO102 (Empty Buffer links) +TRO102_IN = 1Sep | TRO 102_IN(1Sep) +TRO103 = 1Sep | TRO 103 (1Sep) +TRO104 = 1Sep | TRO 104 (1Sep)+Scanner +TRO105 = 1Sep_SSCC | TRO 105 (1Sep)+Scanner +TRO106 = 1Sep | TRO 106 (1Sep) +TRO107 = 1Sep1Swi | TRO 107(1Sep1Swi) +TRO108 = 1Sep | TRO 108 (1Sep) +TRO109 = 1Sep | TRO 109 (1Sep)+Scanner +TRO110 = 1Sep_SSCC | TRO 110 (1Sep)+Scanner +TRO111 = 1Sep | TRO 111 (1Sep) +TRO112 = 1Sep1Swi | TRO 112 (1Sep1Swi) +TRO113 = 1Sep | TRO 113 (1Sep)+Scanner +TRO114 = 1Sep1Swi | TRO 114 (1Sep1Switch)+Scanner +TRO115 = Vario | TRO 115 (Vario) +TRO116 = 1Sep | TRO 116 (1Sep) +TRO117 = 1Sep | TRO 117 (1Sep) + Scanner +TRO120 = Vario | TRO 120 (Vario) +TRO121 = Vario | TRO 121(Vario) +TRO122 = 1Sep | TRO 122 (1Sep) +TRO123 = Vario | TRO 123 (Vario) +TRO124 = 1Sep1Swi | TRO 124 (1Sep1Switch) +TRO125 = 1Sep | TRO 125 (1Sep) +TRO126 = Vario | TRO 126 (Vario) +TRO127 = Vario | TRO 127 (Vario) +TRO128 = Vario | TRO 128 (Vario) +TRO129 = 1Sep | TRO 129 (1Sep) +TRO130 = 1Sep | TRO 130 (1Sep) +TRO131 = Vario | TRO 131 (Vario) +TRO133 = Vario | TRO 133 (Vario) +TRO134 = Vario | TRO 134 (Vario) +fbLoadingBoom1 = LoadingBoom_INBOUND | LoadingBoom 1 +fbLoadingBoom2 = LoadingBoom_INBOUND | LoadingBoom 2 + +[UH01.connections] +c001 = TRO128 -> TRO100 | JA0100_1 | finger +c002 = TRO100 -> TRO101_IN | JA0101_1 | normal +c003 = TRO101_IN -> TRO102_IN | JA0101_2 | normal +c004 = TRO102 -> TRO107 | JA0102_1 | normal +c005 = TRO117 -> TRO107 | JA0102_1 | normal +c006 = TRO101 -> TRO112 | JA0102_2 | normal +c007 = TRO106 -> TRO112 | JA0102_2 | normal +c008 = TRO107 -> TRO112 | JA0102_2 | dir2 +c009 = TRO111 -> TRO113 | JA0102_3 | normal +c010 = TRO112 -> TRO113 | JA0102_3 | dir2 +c011 = TRO113 -> TRO114 | JA0102_4 | normal +c012 = TRO114 -> TRO116 | JA0102_5 | dir2 +c013 = TRO116 -> TRO117 | JA0102_6 | normal +c014 = TRO107 -> TRO103 | JA0103_1 | normal +c015 = TRO103 -> TRO104 | JA0104_1 | normal +c016 = TRO104 -> fbLoadingBoom1 | JA0104_2 | normal +c017 = fbLoadingBoom1 -> TRO105 | JA0104_3 | normal +c018 = TRO105 -> TRO106 | JA0106_2 | normal +c019 = TRO112 -> TRO108 | JA0107_1 | normal +c020 = TRO108 -> TRO109 | JA0108_1 | normal +c021 = TRO109 -> fbLoadingBoom2 | JA0108_2 | normal +c022 = fbLoadingBoom2 -> TRO110 | JA0108_3 | normal +c023 = TRO110 -> TRO111 | JA0110_2 | normal +c024 = TRO115 -> TRO120 | JA4103_1 | finger +c025 = TRO125 -> TRO126 | JA4203_1 | normal +c026 = TRO129 -> TRO130 | JA4204_1 | normal +c027 = TRO124 -> TRO125 | JA4204_2 | normal +c028 = TRO133 -> TRO129 | JA4302_2 | finger +c029 = TRO134 -> TRO131 | JA4403_1 | finger +c030 = TRO124 -> TRO127 | JA4501_1 | dir2 +c031 = TRO130 -> TRO127 | JA4501_1 | normal +c032 = TRO127 -> TRO128 | JA4501_2 | finger +c033 = TRO122 -> TRO123 | JA4502_1 | normal +c034 = TRO123 -> TRO124 | JA4502_2 | finger +c035 = TRO121 -> TRO122 | JA4503_2 | finger +c036 = TRO101_IN -> TRO101 | JamBuffer101 | normal +c037 = TRO102_IN -> TRO102 | JamBuffer102 | normal + +[UH01.externals] +e001 = EXTERN -> TRO115 | JA4104_1 +e002 = EXTERN -> TRO133 | JA4302_1 +e003 = EXTERN -> TRO134 | JA4402_1 +e004 = EXTERN -> TRO121 | JA4503_1 + +[UH02.nodes] +TRO200 = Vario | TRO 200 (Vario) +TRO201 = 1Sep | TRO 201 (1Sep) +TRO202 = 1Sep1Swi | TRO 202 (1Sep1Switch)+Scanner(BX2103) +TRO203 = 1Sep1Swi | TRO 203 (1Sep1Switch) + Scanner (BX2111) +TRO204 = 1Sep1Swi | TRO 204(1Sep1Switch) + Scanner(BX2112) +TRO205 = 1Sep1Swi | TRO 205 (1Sep1Switch) + Scanner(BX2114) +TRO206 = 1Sep1Swi | TRO 206 (1Sep1Switch)+Scanner(BX2113) +TRO207 = 1Sep | TRO 207(1Sep) +TRO208 = PinStore_Auto | Aufruf: TRO208 +TRO209 = Vario | TRO 209 (Vario) +TRO210 = 1Sep | TRO 210 (1Sep) +TRO211 = PinStore_Auto | Aufruf: TRO211 +TRO212 = Vario | TRO 212 (Vario) +TRO213 = 1Sep | TRO 213 (1Sep) +TRO214 = PinStore_Auto | Aufruf: TRO214 +TRO215 = Vario | TRO 215 (Vario) +TRO216 = 1Sep | TRO 216 (1Sep) +TRO217 = PinStore_Auto | Aufruf: TRO217 +TRO218 = Vario | TRO 218 (Vario) +TRO219 = 1Sep | TRO 219(1Sep) +TRO220 = Vario | TRO 220 (Vario) +TRO221 = 1Sep | TRO 221 (1Sep) +TRO222 = 1Sep1Swi | TRO 222 (1Sep1Switch)+Scanner(BX2121) +TRO223 = 1Sep1Swi | TRO 223 (1Sep1Switch)+Scanner(BX2126) +TRO224 = 1Sep1Swi | TRO 224 (1Sep1Switch)+Scanner(BX2127) +TRO225 = 1Sep1Swi | TRO 225(1Sep1Switch)+Scanner(BX2129) +TRO226 = 1Sep1Swi | TRO 226 (1Sep1Switch)+Scanner(BX2128) +TRO227 = 1Sep | TRO 227 (1Sep) +TRO228 = PinStore_Auto | Aufruf: TRO228 +TRO229 = Vario | TRO 229 (Vario) +TRO230 = 1Sep | TRO 230 (1Sep) +TRO231 = PinStore_Auto | Aufruf: TRO231 +TRO232 = Vario | TRO 232 (Vario) +TRO233 = 1Sep | TRO 233 (1Sep) +TRO234 = PinStore_Auto | Aufruf: TRO234 +TRO235 = Vario | TRO 235 (Vario) +TRO236 = 1Sep | TRO 236 (1Sep) +TRO237 = PinStore_Auto | Aufruf: TRO237 +TRO238 = Vario | TRO 238 (Vario) +TRO239 = 1Sep | TRO 239 (1Sep) +TRO240 = Vario | TRO 240 (Vario) +TRO241 = 1Sep | TRO 241(1Sep) +TRO242 = 1Sep1Swi | TRO 242 (1Sep1Switch)+Scanner(BX2130) +TRO243 = 1Sep1Swi | TRO 243 (1Sep1Switch)+Scanner(BX3137) +TRO244 = 1Sep1Swi | TRO 244 (1Sep1Switch)+Scanner(BX2136) +TRO245 = 1Sep1Swi | TRO 245 (1Sep1Switch)+Scanner(BX2138) +TRO246 = 1Sep1Swi | TRO 246 (1Sep1Switch)+Scanner(BX2137) +TRO247 = 1Sep | TRO 247(1Sep) +TRO248 = PinStore_Auto | Aufruf: TRO248 +TRO249 = Vario | TRO 249 (Vario) +TRO250 = 1Sep | TRO 250 (1Sep) +TRO251 = PinStore_Auto | Aufruf: TRO251 +TRO252 = Vario | TRO 252 (Vario) +TRO253 = 1Sep | TRO 253 (1Sep) +TRO254 = PinStore_Auto | Aufruf: TRO254 +TRO255 = Vario | TRO 255 (Vario) +TRO256 = 1Sep | TRO 256 (1Sep) +TRO257 = PinStore_Auto | Aufruf: TRO257 +TRO258 = Vario | TRO 258 (Vario) +TRO259 = 1Sep | TRO 259 (1Sep) +TRO260 = Vario | TRO 260 (Vario) + Scanner (BX2115) +TRO261 = 1Sep | TRO 261 (1Sep) +TRO262 = Vario | TRO 262 (Vario) + Scanner (BX2109) +TRO263 = 1Sep | TRO 263 (1Sep) +TRO264 = Vario | TRO 264 (Vario) + Scanner (BX2108) +TRO265 = 1Sep | TRO 265 (1Sep) +TRO266 = 1Sep | TRO 266(1Sep) +TRO267 = 1Sep2Swi | TRO 267 (1Sep2Switch)+Scanner(BX2100) +TRO268 = 1Sep2Swi | TRO 268 (1Sep2Switch)+Scanner(BX2101) +TRO269 = 1Sep | TRO 269 (1Sep)+Scanner (BX2102) +TRO270 = Vario | TRO 270 (Vario) +TRO272 = Vario | TRO 272 (Vario) +TRO274 = 1Sep | TRO 274 (1Sep) +TRO275 = 1Sep | TRO 275 (1Sep) + +[UH02.connections] +c001 = TRO202 -> TRO211 | JA1101_1 | dir2 +c002 = TRO213 -> TRO211 | JA1101_1 | normal +c003 = TRO211 -> TRO208 | JA1101_2 | bypass +c004 = TRO210 -> TRO208 | JA1101_2 | normal +c005 = TRO201 -> TRO202 | JA1102_1 | normal +c006 = TRO202 -> TRO214 | JA1102_2 | normal +c007 = TRO216 -> TRO214 | JA1102_2 | normal +c008 = TRO214 -> TRO217 | JA1102_3 | bypass +c009 = TRO219 -> TRO217 | JA1102_3 | normal +c010 = TRO208 -> TRO203 | JA1103_1 | normal +c011 = TRO211 -> TRO204 | JA1103_2 | normal +c012 = TRO203 -> TRO204 | JA1103_2 | dir2 +c013 = TRO217 -> TRO205 | JA1104_1 | normal +c014 = TRO214 -> TRO206 | JA1104_2 | normal +c015 = TRO205 -> TRO206 | JA1104_2 | normal +c016 = TRO204 -> TRO207 | JA1104_3 | dir2 +c017 = TRO206 -> TRO207 | JA1104_3 | normal +c018 = TRO203 -> TRO209 | JA1105_1 | normal +c019 = TRO209 -> TRO210 | JA1105_2 | finger +c020 = TRO204 -> TRO212 | JA1106_1 | normal +c021 = TRO212 -> TRO213 | JA1106_2 | finger +c022 = TRO206 -> TRO215 | JA1107_1 | dir2 +c023 = TRO215 -> TRO216 | JA1107_2 | finger +c024 = TRO205 -> TRO218 | JA1108_1 | dir2 +c025 = TRO218 -> TRO219 | JA1108_2 | finger +c026 = TRO200 -> TRO201 | JA1109_2 | finger +c027 = TRO268 -> TRO269 | JA1110_1 | dir3 +c028 = TRO261 -> TRO274 | JA1110_2 | normal +c029 = TRO269 -> TRO274 | JA1110_2 | normal +c030 = TRO263 -> TRO266 | JA1110_3 | normal +c031 = TRO274 -> TRO266 | JA1110_3 | normal +c032 = TRO265 -> TRO267 | JA1110_4 | normal +c033 = TRO266 -> TRO267 | JA1110_4 | normal +c034 = TRO267 -> TRO275 | JA1110_5 | dir3 +c035 = TRO275 -> TRO268 | JA1110_6 | normal +c036 = TRO222 -> TRO231 | JA1201_1 | dir2 +c037 = TRO233 -> TRO231 | JA1201_1 | normal +c038 = TRO231 -> TRO228 | JA1201_2 | bypass +c039 = TRO230 -> TRO228 | JA1201_2 | normal +c040 = TRO221 -> TRO222 | JA1202_1 | normal +c041 = TRO222 -> TRO234 | JA1202_2 | normal +c042 = TRO236 -> TRO234 | JA1202_2 | normal +c043 = TRO234 -> TRO237 | JA1202_3 | bypass +c044 = TRO239 -> TRO237 | JA1202_3 | normal +c045 = TRO228 -> TRO223 | JA1203_1 | normal +c046 = TRO231 -> TRO224 | JA1203_2 | normal +c047 = TRO223 -> TRO224 | JA1203_2 | dir2 +c048 = TRO237 -> TRO225 | JA1204_1 | normal +c049 = TRO234 -> TRO226 | JA1204_2 | normal +c050 = TRO225 -> TRO226 | JA1204_2 | normal +c051 = TRO224 -> TRO227 | JA1204_3 | dir2 +c052 = TRO226 -> TRO227 | JA1204_3 | normal +c053 = TRO223 -> TRO229 | JA1205_1 | normal +c054 = TRO229 -> TRO230 | JA1205_2 | finger +c055 = TRO224 -> TRO232 | JA1206_1 | normal +c056 = TRO232 -> TRO233 | JA1206_2 | finger +c057 = TRO226 -> TRO235 | JA1207_1 | dir2 +c058 = TRO235 -> TRO236 | JA1207_2 | finger +c059 = TRO225 -> TRO238 | JA1208_1 | dir2 +c060 = TRO238 -> TRO239 | JA1208_2 | finger +c061 = TRO220 -> TRO221 | JA1209_2 | finger +c062 = TRO248 -> TRO243 | JA1301_1 | normal +c063 = TRO251 -> TRO244 | JA1301_2 | normal +c064 = TRO243 -> TRO244 | JA1301_2 | normal +c065 = TRO257 -> TRO245 | JA1302_1 | normal +c066 = TRO254 -> TRO246 | JA1302_2 | normal +c067 = TRO245 -> TRO246 | JA1302_2 | dir2 +c068 = TRO242 -> TRO251 | JA1303_1 | normal +c069 = TRO253 -> TRO251 | JA1303_1 | normal +c070 = TRO251 -> TRO248 | JA1303_2 | bypass +c071 = TRO250 -> TRO248 | JA1303_2 | normal +c072 = TRO241 -> TRO242 | JA1304_1 | normal +c073 = TRO242 -> TRO254 | JA1304_2 | dir2 +c074 = TRO256 -> TRO254 | JA1304_2 | normal +c075 = TRO254 -> TRO257 | JA1304_3 | bypass +c076 = TRO259 -> TRO257 | JA1304_3 | normal +c077 = TRO243 -> TRO249 | JA1305_1 | dir2 +c078 = TRO249 -> TRO250 | JA1305_2 | finger +c079 = TRO244 -> TRO252 | JA1306_1 | dir2 +c080 = TRO252 -> TRO253 | JA1306_2 | finger +c081 = TRO246 -> TRO255 | JA1307_1 | normal +c082 = TRO255 -> TRO256 | JA1307_2 | finger +c083 = TRO245 -> TRO258 | JA1308_1 | normal +c084 = TRO258 -> TRO259 | JA1308_2 | finger +c085 = TRO240 -> TRO241 | JA1309_2 | finger +c086 = TRO264 -> TRO265 | JA1401_2 | finger +c087 = TRO262 -> TRO263 | JA1501_2 | finger +c088 = TRO260 -> TRO261 | JA1601_2 | finger + +[UH02.externals] +e001 = EXTERN -> TRO200 | JA1109_1 +e002 = EXTERN -> TRO220 | JA1209_1 +e003 = TRO244 -> EXTERN | JA1302_3 +e004 = TRO246 -> EXTERN | JA1302_3 +e005 = EXTERN -> TRO240 | JA1309_1 +e006 = EXTERN -> TRO264 | JA1401_1 +e007 = EXTERN -> TRO262 | JA1501_1 +e008 = EXTERN -> TRO260 | JA1601_1 +e009 = EXTERN -> TRO272 | JA1801_1 +e010 = EXTERN -> TRO270 | JA4701_1 +e011 = EXTERN -> TRO208 | Storage1.1.1 +e012 = EXTERN -> TRO211 | Storage1.1.2 +e013 = EXTERN -> TRO214 | Storage1.1.3 +e014 = EXTERN -> TRO217 | Storage1.1.4 +e015 = EXTERN -> TRO228 | Storage1.2.1 +e016 = EXTERN -> TRO231 | Storage1.2.2 +e017 = EXTERN -> TRO234 | Storage1.2.3 +e018 = EXTERN -> TRO237 | Storage1.2.4 +e019 = EXTERN -> TRO248 | Storage1.3.1 +e020 = EXTERN -> TRO251 | Storage1.3.2 +e021 = EXTERN -> TRO254 | Storage1.3.3 +e022 = EXTERN -> TRO257 | Storage1.3.4 +e023 = TRO207 -> EXTERN | IO_Device_UH02_TO_UH01.stCARRIER_INFO +e024 = TRO227 -> EXTERN | IO_Device_UH02_TO_UH01.stCARRIER_INFO_1 +e025 = TRO247 -> EXTERN | IO_Device_UH02_TO_UH01.stCARRIER_INFO_2 + +[UH03.nodes] +TRO300 = Vario | TRO 300 (Vario) +TRO301 = 1Sep | TRO 301(1Sep) +TRO302 = Vario | TRO 302 (Vario) +TRO303 = Vario | TRO 303 (Vario) +TRO304 = 1Sep | TRO 304(1Sep) +TRO305 = Vario | TRO 305 (Vario) +TRO306 = Vario | TRO 306 (Vario) +TRO307 = Vario | TRO 307 (Vario) +TRO308 = Vario | TRO 308 (Vario) +TRO309 = 1Sep | TRO 309 (1Sep) +TRO310 = 1Sep | TRO 310 (1Sep)+Scanner (BX3102) +TRO311 = 1Sep | TRO 311 (1Sep)+Scanner(BX3101) +TRO312 = 1Sep | TRO 312 (1Sep)+Scanner(BX3100) +TRO313 = 1Sep1Swi | TRO 313 (1Sep1Switch)+Scanner(BX3103) +TRO314 = 1Sep1Swi | TRO 314 (1Sep1Switch)+Scanner(BX3104) +TRO315 = 1Sep | TRO 315 (1Sep) +TRO316 = 1Sep | TRO 316 (1Sep) +TRO317 = 1Sep1Swi | TRO 317 (1Sep1Switch)+Scanner(BX3105) +TRO318 = 1Sep1Swi | TRO 318 (1Sep1Switch) + Scanner(BX3106) +TRO319 = 1Sep1Swi | TRO 319 (1Sep1Switch) + Scanner (BX3111) +TRO320 = 1Sep1Swi | TRO 320 (1Sep1Switch) + Scanner(BX3112) +TRO321 = 1Sep1Swi | TRO 321 (1Sep1Switch) + Scanner(BX3114) +TRO322 = 1Sep1Swi | TRO 322 (1Sep1Switch)+Scanner(BX3113) +TRO323 = 1Sep | TRO 323 (1Sep) +TRO324 = Vario | TRO 324 (Vario) +TRO325 = 1Sep | TRO 325 (1Sep) +TRO326 = 1Sep | TRO 326 (1Sep) +TRO327 = PinStore_Auto | Aufruf: TRO327 +TRO328 = Vario | TRO 328 (Vario) +TRO329 = 1Sep | TRO 329 (1Sep) +TRO330 = PinStore_Auto | Aufruf: TRO330 +TRO331 = Vario | TRO 331 (Vario) +TRO332 = 1Sep | TRO 332 (1Sep) +TRO333 = PinStore_Auto | Aufruf: TRO333 +TRO334 = Vario | TRO 334 (Vario) +TRO335 = 1Sep | TRO 335 (1Sep) +TRO336 = PinStore_Auto | Aufruf: TRO336 +TRO337 = Vario | TRO 337 (Vario) +TRO338 = 1Sep | TRO 338 (1Sep) +TRO339 = 1Sep1Swi | TRO 339 (1Sep1Switch)+Scanner(BX3120) +TRO340 = 1Sep1Swi | TRO 340 (1Sep1Switch)+Scanner(BX3121) +TRO341 = 1Sep1Swi | TRO 341 (1Sep1Switch)+Scanner(BX3126) +TRO342 = 1Sep1Swi | TRO 342 (1Sep1Switch)+Scanner(BX3127) +TRO343 = 1Sep1Swi | TRO 343 (1Sep1Switch)+Scanner(BX3129) +TRO344 = 1Sep1Swi | TRO 344 (1Sep1Switch)+Scanner(BX3128) +TRO345 = 1Sep | TRO 345 (1Sep) +TRO346 = Vario | TRO 346 (Vario) +TRO347 = 1Sep | TRO 347 (1Sep) +TRO348 = 1Sep | TRO 348 (1Sep) +TRO349 = PinStore_Auto | Aufruf: TRO349 +TRO350 = Vario | TRO 350 (Vario) +TRO351 = 1Sep | TRO 351 (1Sep) +TRO352 = PinStore_Auto | Aufruf: TRO352 +TRO353 = Vario | TRO 353 (Vario) +TRO354 = 1Sep | TRO 354 (1Sep) +TRO355 = PinStore_Auto | Aufruf: TRO355 +TRO356 = Vario | TRO 356 (Vario) +TRO357 = 1Sep | TRO 357 (1Sep) +TRO358 = PinStore_Auto | Aufruf: TRO358 +TRO359 = Vario | TRO 359 (Vario) +TRO360 = 1Sep | TRO 360 (1Sep) +TRO361 = 1Sep1Swi | TRO 361 (1Sep1Switch)+Scanner(BX3131) +TRO362 = 1Sep1Swi | TRO 362 (1Sep1Switch)+Scanner(BX3132) +TRO363 = 1Sep1Swi | TRO 363 (1Sep1Switch)+Scanner(BX3137) +TRO364 = 1Sep1Swi | TRO 364 (1Sep1Switch)+Scanner(BX3138) +TRO365 = 1Sep1Swi | TRO 365 (1Sep1Switch)+Scanner(BX3140) +TRO366 = 1Sep1Swi | TRO 366 (1Sep1Switch)+Scanner(BX3139) +TRO367 = 1Sep | TRO 367 (1Sep) +TRO368 = Vario | TRO 368 (Vario, from Lvl1) +TRO369 = 1Sep | TRO 369 (1Sep) +TRO370 = 1Sep | TRO 370 (1Sep) +TRO371 = PinStore_Auto | Aufruf: TRO371 +TRO372 = Vario | TRO 372 (Vario) +TRO373 = 1Sep | TRO 373 (1Sep) +TRO374 = PinStore_Auto | Aufruf: TRO374 +TRO375 = Vario | TRO 375 (Vario) +TRO376 = 1Sep | TRO 376 (1Sep) +TRO377 = PinStore_Auto | Aufruf: TRO377 +TRO378 = Vario | TRO 378 (Vario) +TRO379 = 1Sep | TRO 379 (1Sep) +TRO380 = PinStore_Auto | Aufruf: TRO380 +TRO381 = Vario | TRO 381 (Vario) +TRO382 = 1Sep | TRO 382 (1Sep) +TRO386 = 1Sep | TRO 386 (1Sep) - kam später dazu + +[UH03.connections] +c001 = TRO318 -> TRO330 | JA2101_1 | dir2 +c002 = TRO332 -> TRO330 | JA2101_1 | normal +c003 = TRO330 -> TRO327 | JA2101_2 | bypass +c004 = TRO329 -> TRO327 | JA2101_2 | normal +c005 = TRO315 -> TRO317 | JA2102_1 | normal +c006 = TRO317 -> TRO318 | JA2102_2 | normal +c007 = TRO318 -> TRO333 | JA2102_3 | normal +c008 = TRO335 -> TRO333 | JA2102_3 | normal +c009 = TRO333 -> TRO336 | JA2102_4 | bypass +c010 = TRO338 -> TRO336 | JA2102_4 | normal +c011 = TRO327 -> TRO319 | JA2103_1 | normal +c012 = TRO330 -> TRO320 | JA2103_2 | normal +c013 = TRO319 -> TRO320 | JA2103_2 | dir2 +c014 = TRO336 -> TRO321 | JA2104_1 | normal +c015 = TRO333 -> TRO322 | JA2104_2 | normal +c016 = TRO321 -> TRO322 | JA2104_2 | normal +c017 = TRO320 -> TRO323 | JA2104_3 | dir2 +c018 = TRO322 -> TRO323 | JA2104_3 | normal +c019 = TRO323 -> TRO326 | JA2104_4 | normal +c020 = TRO325 -> TRO326 | JA2104_4 | normal +c021 = TRO319 -> TRO328 | JA2105_1 | normal +c022 = TRO328 -> TRO329 | JA2105_2 | finger +c023 = TRO320 -> TRO331 | JA2106_1 | normal +c024 = TRO331 -> TRO332 | JA2106_2 | finger +c025 = TRO322 -> TRO334 | JA2107_1 | dir2 +c026 = TRO334 -> TRO335 | JA2107_2 | finger +c027 = TRO321 -> TRO337 | JA2108_1 | dir2 +c028 = TRO337 -> TRO338 | JA2108_2 | finger +c029 = TRO324 -> TRO325 | JA2109_2 | finger +c030 = TRO386 -> TRO310 | JA2110_1 | normal +c031 = TRO310 -> TRO313 | JA2110_2 | normal +c032 = TRO311 -> TRO313 | JA2110_2 | normal +c033 = TRO312 -> TRO313 | JA2110_2 | normal +c034 = TRO313 -> TRO314 | JA2110_3 | dir2 +c035 = TRO314 -> TRO315 | JA2110_4 | dir2 +c036 = TRO309 -> TRO386 | JA2110_5 | normal +c037 = TRO308 -> TRO309 | JA2111_2 | finger +c038 = TRO313 -> TRO316 | JA2112_1 | normal +c039 = TRO340 -> TRO352 | JA2201_1 | dir2 +c040 = TRO354 -> TRO352 | JA2201_1 | normal +c041 = TRO352 -> TRO349 | JA2201_2 | bypass +c042 = TRO351 -> TRO349 | JA2201_2 | normal +c043 = TRO314 -> TRO339 | JA2202_1 | normal +c044 = TRO339 -> TRO340 | JA2202_2 | normal +c045 = TRO340 -> TRO355 | JA2202_3 | normal +c046 = TRO357 -> TRO355 | JA2202_3 | normal +c047 = TRO355 -> TRO358 | JA2202_4 | bypass +c048 = TRO360 -> TRO358 | JA2202_4 | normal +c049 = TRO349 -> TRO341 | JA2203_1 | normal +c050 = TRO352 -> TRO342 | JA2203_2 | normal +c051 = TRO341 -> TRO342 | JA2203_2 | dir2 +c052 = TRO358 -> TRO343 | JA2204_1 | normal +c053 = TRO355 -> TRO344 | JA2204_2 | normal +c054 = TRO343 -> TRO344 | JA2204_2 | normal +c055 = TRO342 -> TRO345 | JA2204_3 | dir2 +c056 = TRO344 -> TRO345 | JA2204_3 | normal +c057 = TRO345 -> TRO348 | JA2204_4 | normal +c058 = TRO347 -> TRO348 | JA2204_4 | normal +c059 = TRO341 -> TRO350 | JA2205_1 | normal +c060 = TRO350 -> TRO351 | JA2205_2 | finger +c061 = TRO342 -> TRO353 | JA2206_1 | normal +c062 = TRO353 -> TRO354 | JA2206_2 | finger +c063 = TRO344 -> TRO356 | JA2207_1 | dir2 +c064 = TRO356 -> TRO357 | JA2207_2 | finger +c065 = TRO343 -> TRO359 | JA2208_1 | dir2 +c066 = TRO359 -> TRO360 | JA2208_2 | finger +c067 = TRO346 -> TRO347 | JA2209_2 | finger +c068 = TRO371 -> TRO363 | JA2301_1 | normal +c069 = TRO374 -> TRO364 | JA2301_2 | normal +c070 = TRO363 -> TRO364 | JA2301_2 | normal +c071 = TRO380 -> TRO365 | JA2302_1 | normal +c072 = TRO377 -> TRO366 | JA2302_2 | normal +c073 = TRO365 -> TRO366 | JA2302_2 | dir2 +c074 = TRO364 -> TRO367 | JA2302_3 | normal +c075 = TRO366 -> TRO367 | JA2302_3 | dir2 +c076 = TRO367 -> TRO370 | JA2302_4 | normal +c077 = TRO369 -> TRO370 | JA2302_4 | normal +c078 = TRO362 -> TRO374 | JA2303_1 | normal +c079 = TRO376 -> TRO374 | JA2303_1 | normal +c080 = TRO374 -> TRO371 | JA2303_2 | bypass +c081 = TRO373 -> TRO371 | JA2303_2 | normal +c082 = TRO316 -> TRO361 | JA2304_1 | normal +c083 = TRO361 -> TRO362 | JA2304_2 | dir2 +c084 = TRO362 -> TRO377 | JA2304_3 | dir2 +c085 = TRO379 -> TRO377 | JA2304_3 | normal +c086 = TRO377 -> TRO380 | JA2304_4 | bypass +c087 = TRO382 -> TRO380 | JA2304_4 | normal +c088 = TRO363 -> TRO372 | JA2305_1 | dir2 +c089 = TRO372 -> TRO373 | JA2305_2 | finger +c090 = TRO364 -> TRO375 | JA2306_1 | dir2 +c091 = TRO375 -> TRO376 | JA2306_2 | finger +c092 = TRO366 -> TRO378 | JA2307_1 | normal +c093 = TRO378 -> TRO379 | JA2307_2 | finger +c094 = TRO365 -> TRO381 | JA2308_1 | normal +c095 = TRO381 -> TRO382 | JA2308_2 | finger +c096 = TRO368 -> TRO369 | JA2309_2 | finger +c097 = TRO300 -> TRO302 | JA4101_1 | finger +c098 = TRO301 -> TRO302 | JA4101_1 | normal +c099 = TRO302 -> TRO311 | JA4101_2 | finger +c100 = TRO303 -> TRO305 | JA4201_1 | finger +c101 = TRO304 -> TRO305 | JA4201_1 | normal +c102 = TRO305 -> TRO312 | JA4201_2 | finger + +[UH03.externals] +e001 = TRO336 -> EXTERN | JA2102_5 +e002 = EXTERN -> TRO324 | JA2109_1 +e003 = EXTERN -> TRO308 | JA2111_1 +e004 = TRO358 -> EXTERN | JA2202_5 +e005 = EXTERN -> TRO346 | JA2209_1 +e006 = EXTERN -> TRO368 | JA2309_1 +e007 = EXTERN -> TRO300 | JA4102_1 +e008 = EXTERN -> TRO301 | JA4102_2 +e009 = EXTERN -> TRO303 | JA4202_1 +e010 = EXTERN -> TRO304 | JA4202_2 +e011 = EXTERN -> TRO306 | JA4301_1 +e012 = EXTERN -> TRO307 | JA4401_1 +e013 = EXTERN -> TRO327 | Storage2.1.1 +e014 = EXTERN -> TRO330 | Storage2.1.2 +e015 = EXTERN -> TRO333 | Storage2.1.3 +e016 = EXTERN -> TRO336 | Storage2.1.4 +e017 = EXTERN -> TRO349 | Storage2.2.1 +e018 = EXTERN -> TRO352 | Storage2.2.2 +e019 = EXTERN -> TRO355 | Storage2.2.3 +e020 = EXTERN -> TRO358 | Storage2.2.4 +e021 = EXTERN -> TRO371 | Storage2.3.1 +e022 = EXTERN -> TRO374 | Storage2.3.2 +e023 = EXTERN -> TRO377 | Storage2.3.3 +e024 = EXTERN -> TRO380 | Storage2.3.4 +e025 = TRO326 -> EXTERN | IO_Device_UH03_TO_UH01.stCARRIER_INFO +e026 = TRO348 -> EXTERN | IO_Device_UH03_TO_UH01.stCARRIER_INFO_1 +e027 = TRO370 -> EXTERN | IO_Device_UH03_TO_UH01.stCARRIER_INFO_2 +e028 = TRO317 -> EXTERN | IO_Device_UH03_TO_UH01.stCarrierL2toL1 +e029 = TRO339 -> EXTERN | IO_Device_UH03_TO_UH01.stCarrierL2toL1_2 +e030 = TRO361 -> EXTERN | IO_Device_UH03_TO_UH01.stCarrierL2toL1_3 + +[UH04.nodes] +TRO400 = Vario | TRO 400 (Vario) +TRO401 = Vario | TRO 401 (Vario) +TRO402 = 1Sep | TRO 402 (1Sep) (Vor Brandschutztor) +TRO403 = Vario | TRO 403 (Vario) +TRO404 = 1Sep | TRO 404 (1Sep) +TRO405 = 1Sep1Swi | TRO 405 (1Sep1Switch) + Scanner (BX4100) + Behangskontrolle +TRO406 = 1Sep | TRO 406 (1Sep) + Scanner (BX4101) +TRO407 = 1Sep1Swi | TRO 407 (1Sep1Switch) + Scanner (BX4102) +TRO408 = Vario | TRO 408 (Vario) +TRO409 = 1Sep | TRO 409 (1Sep) +TRO410 = 1Sep1Swi | TRO 410 (1Sep1Switch) + Scanner (BX4104) +TRO411 = Vario | TRO 411 (Vario) +TRO412 = 1Sep | TRO 412 (1Sep) +TRO413 = 1Sep1Swi | TRO 413(1Sep1Switch)+Scanner(BX4106) +TRO414 = Vario | TRO 414 (Vario) +TRO415 = 1Sep | TRO 415 (1Sep) +TRO416 = 1Sep | TRO 416 (1Sep) + Beladeprüfung +TRO417 = 1Sep | TRO 417 (1Sep) +TRO418 = Vario | TRO 418 (Vario) +TRO420 = Vario | TRO 420 (Vario) +TRO421 = Vario_workStation | TRO 421 (Vario) +TRO422 = Vario_workStation | TRO 422 (Vario) +TRO423 = Vario_workStation | TRO 423 (Vario) +TRO424 = 1Sep | TRO 424 (1Sep) vor Behangskontrolle + +[UH04.connections] +c001 = TRO400 -> TRO401 | JA4001_1 | finger +c002 = TRO401 -> TRO402 | JA4001_2 | finger +c003 = TRO402 -> TRO403 | JA4002_1 | normal +c004 = TRO403 -> TRO404 | JA4002_2 | finger +c005 = TRO424 -> TRO405 | JA4003_1 | normal +c006 = TRO405 -> TRO406 | JA4003_2 | dir2 +c007 = TRO406 -> TRO407 | JA4003_3 | normal +c008 = TRO407 -> TRO410 | JA4003_4 | dir2 +c009 = TRO409 -> TRO410 | JA4003_4 | normal +c010 = TRO410 -> TRO413 | JA4003_5 | dir2 +c011 = TRO412 -> TRO413 | JA4003_5 | normal +c012 = TRO413 -> TRO416 | JA4003_6 | dir2 +c013 = TRO415 -> TRO416 | JA4003_6 | normal +c014 = TRO416 -> TRO417 | JA4003_7 | normal +c015 = TRO404 -> TRO424 | JA4003_8 | normal +c016 = TRO417 -> TRO424 | JA4003_8 | normal +c017 = TRO407 -> TRO408 | JA4004_1 | normal +c018 = TRO408 -> TRO421 | JA4004_2 | finger +c019 = TRO410 -> TRO411 | JA4006_1 | normal +c020 = TRO411 -> TRO422 | JA4006_2 | finger +c021 = TRO422 -> TRO412 | JA4007_1 | finger +c022 = TRO413 -> TRO414 | JA4008_1 | normal +c023 = TRO414 -> TRO423 | JA4008_2 | finger +c024 = TRO423 -> TRO415 | JA4009_1 | finger +c025 = TRO418 -> TRO420 | JA4011_1 | finger + +[UH04.externals] +e001 = EXTERN -> TRO400 | JA4000_1 +e002 = TRO421 -> EXTERN | JA4005_1 +e003 = EXTERN -> TRO418 | JA4010_1 + +[UH05.nodes] +TRO500 = Vario | TRO 500 (Vario) - Stand: Vorbereitet für Umbau! +TRO501 = 1Sep | TRO 501 (1Sep) + Scanner (BX5101) +TRO502 = Vario | TRO 502 (Vario) - Stand: Vorbereitet für Umbau! +TRO503 = 1Sep | TRO 503 (1Sep)+ Scanner (BX5100) +TRO504 = 1Sep | TRO 504 (1Sep) +TRO505 = 1Sep1Swi | TRO 505 (1Sep1Switch) + Scanner (BX5102) +TRO506 = Vario | TRO 506 (Vario) +TRO507 = 1Sep | TRO 507 (1Sep) +TRO508 = Vario | TRO 508 (Vario)+Scanner(BX5103) +TRO509 = 1Sep | TRO 509 (1Sep) +TRO510 = 1Sep1Swi | TRO 510 (1Sep1Switch) + Scanner (BX5104) +TRO511 = 1Sep | TRO 511 (1Sep) +TRO512 = Vario | TRO 512 (Vario)+Scanner(BX5105) +TRO513 = 1Sep | TRO 513 (1Sep) +TRO514 = 1Sep1Swi | TRO 514 (1Sep1Switch) + Scanner (BX5106) +TRO515 = 1Sep | TRO 515 (1Sep) +TRO516 = Vario | TRO 516(Vario)+Scanner(BX5107) +TRO517 = 1Sep | TRO 517 (1Sep) +TRO518 = 1Sep1Swi | TRO 518 (1Sep1Switch) + Scanner (BX5108) +TRO519 = 1Sep | TRO 519 (1Sep) +TRO520 = Vario | TRO 520 (Vario)+Scanner(BX5109) +TRO521 = 1Sep | TRO 521(1Sep) +TRO522 = 1Sep1Swi | TRO 522 (1Sep1Switch) + Scanner (BX5110) +TRO523 = 1Sep | TRO 523 (1Sep) +TRO524 = Vario | TRO 524 (Vario)+Scanner(BX5231) +TRO525 = 1Sep | TRO 525(1Sep) +TRO526 = 1Sep | TRO 526 (1Sep) + Scanner (BX5112) +TRO527 = 1Sep1Swi | TRO 527 (1Sep1Switch) +TRO528 = 1Sep | TRO 528 (1Sep) +TRO529 = 1Sep | TRO 529 (1Sep) + Scanner (BX5113) +TRO530 = Vario | TRO 530 (Vario) +TRO531 = Vario | TRO 531 (Vario) + +[UH05.connections] +c001 = TRO502 -> TRO531 | JA5000_2 | finger +c002 = TRO531 -> TRO503 | JA5000_3 | finger +c003 = TRO500 -> TRO530 | JA5001_2 | finger +c004 = TRO530 -> TRO501 | JA5001_3 | finger +c005 = TRO501 -> TRO504 | JA5002_1 | normal +c006 = TRO503 -> TRO504 | JA5002_1 | normal +c007 = TRO529 -> TRO504 | JA5002_1 | normal +c008 = TRO528 -> TRO529 | JA5002_10 | normal +c009 = TRO504 -> TRO505 | JA5002_2 | normal +c010 = TRO505 -> TRO510 | JA5002_3 | dir2 +c011 = TRO509 -> TRO510 | JA5002_3 | normal +c012 = TRO510 -> TRO514 | JA5002_4 | dir2 +c013 = TRO513 -> TRO514 | JA5002_4 | normal +c014 = TRO514 -> TRO518 | JA5002_5 | dir2 +c015 = TRO517 -> TRO518 | JA5002_5 | normal +c016 = TRO518 -> TRO522 | JA5002_6 | dir2 +c017 = TRO521 -> TRO522 | JA5002_6 | normal +c018 = TRO522 -> TRO526 | JA5002_7 | dir2 +c019 = TRO525 -> TRO526 | JA5002_7 | normal +c020 = TRO526 -> TRO527 | JA5002_8 | normal +c021 = TRO527 -> TRO528 | JA5002_9 | dir2 +c022 = TRO505 -> TRO506 | JA5003_1 | normal +c023 = TRO506 -> TRO507 | JA5003_2 | finger +c024 = TRO507 -> TRO508 | JA5004_1 | normal +c025 = TRO510 -> TRO511 | JA5005_1 | normal +c026 = TRO511 -> TRO512 | JA5005_2 | normal +c027 = TRO514 -> TRO515 | JA5006_1 | normal +c028 = TRO515 -> TRO516 | JA5006_2 | normal +c029 = TRO518 -> TRO519 | JA5007_1 | normal +c030 = TRO519 -> TRO520 | JA5007_2 | normal +c031 = TRO522 -> TRO523 | JA5008_1 | normal +c032 = TRO523 -> TRO524 | JA5008_2 | normal + +[UH05.externals] +e001 = EXTERN -> TRO502 | JA5000_1 +e002 = EXTERN -> TRO500 | JA5001_1 +e003 = TRO508 -> EXTERN | JA5004_2 +e004 = TRO512 -> EXTERN | JA5005_3 +e005 = TRO516 -> EXTERN | JA5006_3 +e006 = TRO520 -> EXTERN | JA5007_3 +e007 = TRO524 -> EXTERN | JA5008_3 + diff --git a/data/connect.json b/data/connect.json new file mode 100644 index 0000000..1ab98bf --- /dev/null +++ b/data/connect.json @@ -0,0 +1,3451 @@ +{ + "meta": { + "format": "hmf-connect-v1", + "source": "doc/TRO_Graph_UH01-UH05.dot", + "description": "Routing / Zusammenhalt der TROs je Steuerung. connections: gerichtete Kante von TRO zu TRO ueber eine JamArea. kind: normal|dir2|dir3 (Weichenausgang, Richtung aus FC_Direction)|bypass|finger. externals: offene Enden (Anlagengrenze, WES/WCS, CPU-CPU-Uebergabe)." + }, + "plcs": { + "UH01": { + "nodes": { + "TRO100": { + "fbType": "1Sep", + "comment": "TRO 100 (1Sep)" + }, + "TRO101": { + "fbType": "EmptyCarrBuffer", + "comment": "TRO101 (Empty Buffer rechts)" + }, + "TRO101_IN": { + "fbType": "1Sep", + "comment": "TRO 101_IN(1Sep)" + }, + "TRO102": { + "fbType": "EmptyCarrBuffer", + "comment": "TRO102 (Empty Buffer links)" + }, + "TRO102_IN": { + "fbType": "1Sep", + "comment": "TRO 102_IN(1Sep)" + }, + "TRO103": { + "fbType": "1Sep", + "comment": "TRO 103 (1Sep)" + }, + "TRO104": { + "fbType": "1Sep", + "comment": "TRO 104 (1Sep)+Scanner" + }, + "TRO105": { + "fbType": "1Sep_SSCC", + "comment": "TRO 105 (1Sep)+Scanner" + }, + "TRO106": { + "fbType": "1Sep", + "comment": "TRO 106 (1Sep)" + }, + "TRO107": { + "fbType": "1Sep1Swi", + "comment": "TRO 107(1Sep1Swi)" + }, + "TRO108": { + "fbType": "1Sep", + "comment": "TRO 108 (1Sep)" + }, + "TRO109": { + "fbType": "1Sep", + "comment": "TRO 109 (1Sep)+Scanner" + }, + "TRO110": { + "fbType": "1Sep_SSCC", + "comment": "TRO 110 (1Sep)+Scanner" + }, + "TRO111": { + "fbType": "1Sep", + "comment": "TRO 111 (1Sep)" + }, + "TRO112": { + "fbType": "1Sep1Swi", + "comment": "TRO 112 (1Sep1Swi)" + }, + "TRO113": { + "fbType": "1Sep", + "comment": "TRO 113 (1Sep)+Scanner" + }, + "TRO114": { + "fbType": "1Sep1Swi", + "comment": "TRO 114 (1Sep1Switch)+Scanner" + }, + "TRO115": { + "fbType": "Vario", + "comment": "TRO 115 (Vario)" + }, + "TRO116": { + "fbType": "1Sep", + "comment": "TRO 116 (1Sep)" + }, + "TRO117": { + "fbType": "1Sep", + "comment": "TRO 117 (1Sep) + Scanner" + }, + "TRO120": { + "fbType": "Vario", + "comment": "TRO 120 (Vario)" + }, + "TRO121": { + "fbType": "Vario", + "comment": "TRO 121(Vario)" + }, + "TRO122": { + "fbType": "1Sep", + "comment": "TRO 122 (1Sep)" + }, + "TRO123": { + "fbType": "Vario", + "comment": "TRO 123 (Vario)" + }, + "TRO124": { + "fbType": "1Sep1Swi", + "comment": "TRO 124 (1Sep1Switch)" + }, + "TRO125": { + "fbType": "1Sep", + "comment": "TRO 125 (1Sep)" + }, + "TRO126": { + "fbType": "Vario", + "comment": "TRO 126 (Vario)" + }, + "TRO127": { + "fbType": "Vario", + "comment": "TRO 127 (Vario)" + }, + "TRO128": { + "fbType": "Vario", + "comment": "TRO 128 (Vario)" + }, + "TRO129": { + "fbType": "1Sep", + "comment": "TRO 129 (1Sep)" + }, + "TRO130": { + "fbType": "1Sep", + "comment": "TRO 130 (1Sep)" + }, + "TRO131": { + "fbType": "Vario", + "comment": "TRO 131 (Vario)" + }, + "TRO133": { + "fbType": "Vario", + "comment": "TRO 133 (Vario)" + }, + "TRO134": { + "fbType": "Vario", + "comment": "TRO 134 (Vario)" + }, + "fbLoadingBoom1": { + "fbType": "LoadingBoom_INBOUND", + "comment": "LoadingBoom 1" + }, + "fbLoadingBoom2": { + "fbType": "LoadingBoom_INBOUND", + "comment": "LoadingBoom 2" + } + }, + "connections": [ + { + "from": "TRO128", + "to": "TRO100", + "jamArea": "JA0100_1", + "kind": "finger", + "dbRef": "\"DB_JamArea0100\".stJam0100_1" + }, + { + "from": "TRO100", + "to": "TRO101_IN", + "jamArea": "JA0101_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0101\".stJam0101_1" + }, + { + "from": "TRO101_IN", + "to": "TRO102_IN", + "jamArea": "JA0101_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0101\".stJam0101_2" + }, + { + "from": "TRO102", + "to": "TRO107", + "jamArea": "JA0102_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_1" + }, + { + "from": "TRO117", + "to": "TRO107", + "jamArea": "JA0102_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_1" + }, + { + "from": "TRO101", + "to": "TRO112", + "jamArea": "JA0102_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_2" + }, + { + "from": "TRO106", + "to": "TRO112", + "jamArea": "JA0102_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_2" + }, + { + "from": "TRO107", + "to": "TRO112", + "jamArea": "JA0102_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea0102\".stJam0102_2" + }, + { + "from": "TRO111", + "to": "TRO113", + "jamArea": "JA0102_3", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_3" + }, + { + "from": "TRO112", + "to": "TRO113", + "jamArea": "JA0102_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea0102\".stJam0102_3" + }, + { + "from": "TRO113", + "to": "TRO114", + "jamArea": "JA0102_4", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_4" + }, + { + "from": "TRO114", + "to": "TRO116", + "jamArea": "JA0102_5", + "kind": "dir2", + "dbRef": "\"DB_JamArea0102\".stJam0102_5" + }, + { + "from": "TRO116", + "to": "TRO117", + "jamArea": "JA0102_6", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_6" + }, + { + "from": "TRO107", + "to": "TRO103", + "jamArea": "JA0103_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0103\".stJam0103_1" + }, + { + "from": "TRO103", + "to": "TRO104", + "jamArea": "JA0104_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0104\".stJam0104_1" + }, + { + "from": "TRO104", + "to": "fbLoadingBoom1", + "jamArea": "JA0104_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0104\".stJam0104_2" + }, + { + "from": "fbLoadingBoom1", + "to": "TRO105", + "jamArea": "JA0104_3", + "kind": "normal", + "dbRef": "\"DB_JamArea0104\".stJam0104_3" + }, + { + "from": "TRO105", + "to": "TRO106", + "jamArea": "JA0106_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0106\".stJam0106_2" + }, + { + "from": "TRO112", + "to": "TRO108", + "jamArea": "JA0107_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0107\".stJam0107_1" + }, + { + "from": "TRO108", + "to": "TRO109", + "jamArea": "JA0108_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0108\".stJam0108_1" + }, + { + "from": "TRO109", + "to": "fbLoadingBoom2", + "jamArea": "JA0108_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0108\".stJam0108_2" + }, + { + "from": "fbLoadingBoom2", + "to": "TRO110", + "jamArea": "JA0108_3", + "kind": "normal", + "dbRef": "\"DB_JamArea0108\".stJam0108_3" + }, + { + "from": "TRO110", + "to": "TRO111", + "jamArea": "JA0110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0110\".stJam0110_2" + }, + { + "from": "TRO115", + "to": "TRO120", + "jamArea": "JA4103_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4103\".stJam4103_1" + }, + { + "from": "TRO125", + "to": "TRO126", + "jamArea": "JA4203_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4203\".stJam4203_1" + }, + { + "from": "TRO129", + "to": "TRO130", + "jamArea": "JA4204_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4204\".stJam4204_1" + }, + { + "from": "TRO124", + "to": "TRO125", + "jamArea": "JA4204_2", + "kind": "normal", + "dbRef": "\"DB_JamArea4204\".stJam4204_2" + }, + { + "from": "TRO133", + "to": "TRO129", + "jamArea": "JA4302_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4302\".stJam4302_2" + }, + { + "from": "TRO134", + "to": "TRO131", + "jamArea": "JA4403_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4403\".stJam4403_1" + }, + { + "from": "TRO124", + "to": "TRO127", + "jamArea": "JA4501_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea4501\".stJam4501_1" + }, + { + "from": "TRO130", + "to": "TRO127", + "jamArea": "JA4501_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4501\".stJam4501_1" + }, + { + "from": "TRO127", + "to": "TRO128", + "jamArea": "JA4501_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4501\".stJam4501_2" + }, + { + "from": "TRO122", + "to": "TRO123", + "jamArea": "JA4502_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4502\".stJam4502_1" + }, + { + "from": "TRO123", + "to": "TRO124", + "jamArea": "JA4502_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4502\".stJam4502_2" + }, + { + "from": "TRO121", + "to": "TRO122", + "jamArea": "JA4503_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4503\".stJam4503_2" + }, + { + "from": "TRO101_IN", + "to": "TRO101", + "jamArea": "JamBuffer101", + "kind": "normal", + "dbRef": "JamBuffer101" + }, + { + "from": "TRO102_IN", + "to": "TRO102", + "jamArea": "JamBuffer102", + "kind": "normal", + "dbRef": "JamBuffer102" + } + ], + "externals": [ + { + "node": "TRO115", + "direction": "in", + "jamArea": "JA4104_1", + "dbRef": "\"DB_JamArea4104\".stJam4104_1" + }, + { + "node": "TRO133", + "direction": "in", + "jamArea": "JA4302_1", + "dbRef": "\"DB_JamArea4302\".stJam4302_1" + }, + { + "node": "TRO134", + "direction": "in", + "jamArea": "JA4402_1", + "dbRef": "\"DB_JamArea4402\".stJam4402_1" + }, + { + "node": "TRO121", + "direction": "in", + "jamArea": "JA4503_1", + "dbRef": "\"DB_JamArea4503\".stJam4503_1" + } + ] + }, + "UH02": { + "nodes": { + "TRO200": { + "fbType": "Vario", + "comment": "TRO 200 (Vario)" + }, + "TRO201": { + "fbType": "1Sep", + "comment": "TRO 201 (1Sep)" + }, + "TRO202": { + "fbType": "1Sep1Swi", + "comment": "TRO 202 (1Sep1Switch)+Scanner(BX2103)" + }, + "TRO203": { + "fbType": "1Sep1Swi", + "comment": "TRO 203 (1Sep1Switch) + Scanner (BX2111)" + }, + "TRO204": { + "fbType": "1Sep1Swi", + "comment": "TRO 204(1Sep1Switch) + Scanner(BX2112)" + }, + "TRO205": { + "fbType": "1Sep1Swi", + "comment": "TRO 205 (1Sep1Switch) + Scanner(BX2114)" + }, + "TRO206": { + "fbType": "1Sep1Swi", + "comment": "TRO 206 (1Sep1Switch)+Scanner(BX2113)" + }, + "TRO207": { + "fbType": "1Sep", + "comment": "TRO 207(1Sep)" + }, + "TRO208": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO208" + }, + "TRO209": { + "fbType": "Vario", + "comment": "TRO 209 (Vario)" + }, + "TRO210": { + "fbType": "1Sep", + "comment": "TRO 210 (1Sep)" + }, + "TRO211": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO211" + }, + "TRO212": { + "fbType": "Vario", + "comment": "TRO 212 (Vario)" + }, + "TRO213": { + "fbType": "1Sep", + "comment": "TRO 213 (1Sep)" + }, + "TRO214": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO214" + }, + "TRO215": { + "fbType": "Vario", + "comment": "TRO 215 (Vario)" + }, + "TRO216": { + "fbType": "1Sep", + "comment": "TRO 216 (1Sep)" + }, + "TRO217": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO217" + }, + "TRO218": { + "fbType": "Vario", + "comment": "TRO 218 (Vario)" + }, + "TRO219": { + "fbType": "1Sep", + "comment": "TRO 219(1Sep)" + }, + "TRO220": { + "fbType": "Vario", + "comment": "TRO 220 (Vario)" + }, + "TRO221": { + "fbType": "1Sep", + "comment": "TRO 221 (1Sep)" + }, + "TRO222": { + "fbType": "1Sep1Swi", + "comment": "TRO 222 (1Sep1Switch)+Scanner(BX2121)" + }, + "TRO223": { + "fbType": "1Sep1Swi", + "comment": "TRO 223 (1Sep1Switch)+Scanner(BX2126)" + }, + "TRO224": { + "fbType": "1Sep1Swi", + "comment": "TRO 224 (1Sep1Switch)+Scanner(BX2127)" + }, + "TRO225": { + "fbType": "1Sep1Swi", + "comment": "TRO 225(1Sep1Switch)+Scanner(BX2129)" + }, + "TRO226": { + "fbType": "1Sep1Swi", + "comment": "TRO 226 (1Sep1Switch)+Scanner(BX2128)" + }, + "TRO227": { + "fbType": "1Sep", + "comment": "TRO 227 (1Sep)" + }, + "TRO228": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO228" + }, + "TRO229": { + "fbType": "Vario", + "comment": "TRO 229 (Vario)" + }, + "TRO230": { + "fbType": "1Sep", + "comment": "TRO 230 (1Sep)" + }, + "TRO231": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO231" + }, + "TRO232": { + "fbType": "Vario", + "comment": "TRO 232 (Vario)" + }, + "TRO233": { + "fbType": "1Sep", + "comment": "TRO 233 (1Sep)" + }, + "TRO234": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO234" + }, + "TRO235": { + "fbType": "Vario", + "comment": "TRO 235 (Vario)" + }, + "TRO236": { + "fbType": "1Sep", + "comment": "TRO 236 (1Sep)" + }, + "TRO237": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO237" + }, + "TRO238": { + "fbType": "Vario", + "comment": "TRO 238 (Vario)" + }, + "TRO239": { + "fbType": "1Sep", + "comment": "TRO 239 (1Sep)" + }, + "TRO240": { + "fbType": "Vario", + "comment": "TRO 240 (Vario)" + }, + "TRO241": { + "fbType": "1Sep", + "comment": "TRO 241(1Sep)" + }, + "TRO242": { + "fbType": "1Sep1Swi", + "comment": "TRO 242 (1Sep1Switch)+Scanner(BX2130)" + }, + "TRO243": { + "fbType": "1Sep1Swi", + "comment": "TRO 243 (1Sep1Switch)+Scanner(BX3137)" + }, + "TRO244": { + "fbType": "1Sep1Swi", + "comment": "TRO 244 (1Sep1Switch)+Scanner(BX2136)" + }, + "TRO245": { + "fbType": "1Sep1Swi", + "comment": "TRO 245 (1Sep1Switch)+Scanner(BX2138)" + }, + "TRO246": { + "fbType": "1Sep1Swi", + "comment": "TRO 246 (1Sep1Switch)+Scanner(BX2137)" + }, + "TRO247": { + "fbType": "1Sep", + "comment": "TRO 247(1Sep)" + }, + "TRO248": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO248" + }, + "TRO249": { + "fbType": "Vario", + "comment": "TRO 249 (Vario)" + }, + "TRO250": { + "fbType": "1Sep", + "comment": "TRO 250 (1Sep)" + }, + "TRO251": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO251" + }, + "TRO252": { + "fbType": "Vario", + "comment": "TRO 252 (Vario)" + }, + "TRO253": { + "fbType": "1Sep", + "comment": "TRO 253 (1Sep)" + }, + "TRO254": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO254" + }, + "TRO255": { + "fbType": "Vario", + "comment": "TRO 255 (Vario)" + }, + "TRO256": { + "fbType": "1Sep", + "comment": "TRO 256 (1Sep)" + }, + "TRO257": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO257" + }, + "TRO258": { + "fbType": "Vario", + "comment": "TRO 258 (Vario)" + }, + "TRO259": { + "fbType": "1Sep", + "comment": "TRO 259 (1Sep)" + }, + "TRO260": { + "fbType": "Vario", + "comment": "TRO 260 (Vario) + Scanner (BX2115)" + }, + "TRO261": { + "fbType": "1Sep", + "comment": "TRO 261 (1Sep)" + }, + "TRO262": { + "fbType": "Vario", + "comment": "TRO 262 (Vario) + Scanner (BX2109)" + }, + "TRO263": { + "fbType": "1Sep", + "comment": "TRO 263 (1Sep)" + }, + "TRO264": { + "fbType": "Vario", + "comment": "TRO 264 (Vario) + Scanner (BX2108)" + }, + "TRO265": { + "fbType": "1Sep", + "comment": "TRO 265 (1Sep)" + }, + "TRO266": { + "fbType": "1Sep", + "comment": "TRO 266(1Sep)" + }, + "TRO267": { + "fbType": "1Sep2Swi", + "comment": "TRO 267 (1Sep2Switch)+Scanner(BX2100)" + }, + "TRO268": { + "fbType": "1Sep2Swi", + "comment": "TRO 268 (1Sep2Switch)+Scanner(BX2101)" + }, + "TRO269": { + "fbType": "1Sep", + "comment": "TRO 269 (1Sep)+Scanner (BX2102)" + }, + "TRO270": { + "fbType": "Vario", + "comment": "TRO 270 (Vario)" + }, + "TRO272": { + "fbType": "Vario", + "comment": "TRO 272 (Vario)" + }, + "TRO274": { + "fbType": "1Sep", + "comment": "TRO 274 (1Sep)" + }, + "TRO275": { + "fbType": "1Sep", + "comment": "TRO 275 (1Sep)" + } + }, + "connections": [ + { + "from": "TRO202", + "to": "TRO211", + "jamArea": "JA1101_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1101\".stJam1101_1" + }, + { + "from": "TRO213", + "to": "TRO211", + "jamArea": "JA1101_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1101\".stJam1101_1" + }, + { + "from": "TRO211", + "to": "TRO208", + "jamArea": "JA1101_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea1101\".stJam1101_2" + }, + { + "from": "TRO210", + "to": "TRO208", + "jamArea": "JA1101_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1101\".stJam1101_2" + }, + { + "from": "TRO201", + "to": "TRO202", + "jamArea": "JA1102_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1102\".stJam1102_1" + }, + { + "from": "TRO202", + "to": "TRO214", + "jamArea": "JA1102_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1102\".stJam1102_2" + }, + { + "from": "TRO216", + "to": "TRO214", + "jamArea": "JA1102_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1102\".stJam1102_2" + }, + { + "from": "TRO214", + "to": "TRO217", + "jamArea": "JA1102_3", + "kind": "bypass", + "dbRef": "\"DB_JamArea1102\".stJam1102_3" + }, + { + "from": "TRO219", + "to": "TRO217", + "jamArea": "JA1102_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1102\".stJam1102_3" + }, + { + "from": "TRO208", + "to": "TRO203", + "jamArea": "JA1103_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1103\".stJam1103_1" + }, + { + "from": "TRO211", + "to": "TRO204", + "jamArea": "JA1103_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1103\".stJam1103_2" + }, + { + "from": "TRO203", + "to": "TRO204", + "jamArea": "JA1103_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea1103\".stJam1103_2" + }, + { + "from": "TRO217", + "to": "TRO205", + "jamArea": "JA1104_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1104\".stJam1104_1" + }, + { + "from": "TRO214", + "to": "TRO206", + "jamArea": "JA1104_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1104\".stJam1104_2" + }, + { + "from": "TRO205", + "to": "TRO206", + "jamArea": "JA1104_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1104\".stJam1104_2" + }, + { + "from": "TRO204", + "to": "TRO207", + "jamArea": "JA1104_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea1104\".stJam1104_3" + }, + { + "from": "TRO206", + "to": "TRO207", + "jamArea": "JA1104_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1104\".stJam1104_3" + }, + { + "from": "TRO203", + "to": "TRO209", + "jamArea": "JA1105_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1105\".stJam1105_1" + }, + { + "from": "TRO209", + "to": "TRO210", + "jamArea": "JA1105_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1105\".stJam1105_2" + }, + { + "from": "TRO204", + "to": "TRO212", + "jamArea": "JA1106_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1106\".stJam1106_1" + }, + { + "from": "TRO212", + "to": "TRO213", + "jamArea": "JA1106_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1106\".stJam1106_2" + }, + { + "from": "TRO206", + "to": "TRO215", + "jamArea": "JA1107_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1107\".stJam1107_1" + }, + { + "from": "TRO215", + "to": "TRO216", + "jamArea": "JA1107_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1107\".stJam1107_2" + }, + { + "from": "TRO205", + "to": "TRO218", + "jamArea": "JA1108_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1108\".stJam1108_1" + }, + { + "from": "TRO218", + "to": "TRO219", + "jamArea": "JA1108_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1108\".stJam1108_2" + }, + { + "from": "TRO200", + "to": "TRO201", + "jamArea": "JA1109_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1109\".stJam1109_2" + }, + { + "from": "TRO268", + "to": "TRO269", + "jamArea": "JA1110_1", + "kind": "dir3", + "dbRef": "\"DB_JamArea1110\".stJam1110_1" + }, + { + "from": "TRO261", + "to": "TRO274", + "jamArea": "JA1110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_2" + }, + { + "from": "TRO269", + "to": "TRO274", + "jamArea": "JA1110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_2" + }, + { + "from": "TRO263", + "to": "TRO266", + "jamArea": "JA1110_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_3" + }, + { + "from": "TRO274", + "to": "TRO266", + "jamArea": "JA1110_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_3" + }, + { + "from": "TRO265", + "to": "TRO267", + "jamArea": "JA1110_4", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_4" + }, + { + "from": "TRO266", + "to": "TRO267", + "jamArea": "JA1110_4", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_4" + }, + { + "from": "TRO267", + "to": "TRO275", + "jamArea": "JA1110_5", + "kind": "dir3", + "dbRef": "\"DB_JamArea1110\".stJam1110_5" + }, + { + "from": "TRO275", + "to": "TRO268", + "jamArea": "JA1110_6", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_6" + }, + { + "from": "TRO222", + "to": "TRO231", + "jamArea": "JA1201_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1201\".stJam1201_1" + }, + { + "from": "TRO233", + "to": "TRO231", + "jamArea": "JA1201_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1201\".stJam1201_1" + }, + { + "from": "TRO231", + "to": "TRO228", + "jamArea": "JA1201_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea1201\".stJam1201_2" + }, + { + "from": "TRO230", + "to": "TRO228", + "jamArea": "JA1201_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1201\".stJam1201_2" + }, + { + "from": "TRO221", + "to": "TRO222", + "jamArea": "JA1202_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1202\".stJam1202_1" + }, + { + "from": "TRO222", + "to": "TRO234", + "jamArea": "JA1202_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1202\".stJam1202_2" + }, + { + "from": "TRO236", + "to": "TRO234", + "jamArea": "JA1202_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1202\".stJam1202_2" + }, + { + "from": "TRO234", + "to": "TRO237", + "jamArea": "JA1202_3", + "kind": "bypass", + "dbRef": "\"DB_JamArea1202\".stJam1202_3" + }, + { + "from": "TRO239", + "to": "TRO237", + "jamArea": "JA1202_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1202\".stJam1202_3" + }, + { + "from": "TRO228", + "to": "TRO223", + "jamArea": "JA1203_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1203\".stJam1203_1" + }, + { + "from": "TRO231", + "to": "TRO224", + "jamArea": "JA1203_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1203\".stJam1203_2" + }, + { + "from": "TRO223", + "to": "TRO224", + "jamArea": "JA1203_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea1203\".stJam1203_2" + }, + { + "from": "TRO237", + "to": "TRO225", + "jamArea": "JA1204_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1204\".stJam1204_1" + }, + { + "from": "TRO234", + "to": "TRO226", + "jamArea": "JA1204_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1204\".stJam1204_2" + }, + { + "from": "TRO225", + "to": "TRO226", + "jamArea": "JA1204_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1204\".stJam1204_2" + }, + { + "from": "TRO224", + "to": "TRO227", + "jamArea": "JA1204_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea1204\".stJam1204_3" + }, + { + "from": "TRO226", + "to": "TRO227", + "jamArea": "JA1204_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1204\".stJam1204_3" + }, + { + "from": "TRO223", + "to": "TRO229", + "jamArea": "JA1205_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1205\".stJam1205_1" + }, + { + "from": "TRO229", + "to": "TRO230", + "jamArea": "JA1205_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1205\".stJam1205_2" + }, + { + "from": "TRO224", + "to": "TRO232", + "jamArea": "JA1206_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1206\".stJam1206_1" + }, + { + "from": "TRO232", + "to": "TRO233", + "jamArea": "JA1206_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1206\".stJam1206_2" + }, + { + "from": "TRO226", + "to": "TRO235", + "jamArea": "JA1207_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1207\".stJam1207_1" + }, + { + "from": "TRO235", + "to": "TRO236", + "jamArea": "JA1207_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1207\".stJam1207_2" + }, + { + "from": "TRO225", + "to": "TRO238", + "jamArea": "JA1208_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1208\".stJam1208_1" + }, + { + "from": "TRO238", + "to": "TRO239", + "jamArea": "JA1208_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1208\".stJam1208_2" + }, + { + "from": "TRO220", + "to": "TRO221", + "jamArea": "JA1209_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1209\".stJam1209_2" + }, + { + "from": "TRO248", + "to": "TRO243", + "jamArea": "JA1301_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1301\".stJam1301_1" + }, + { + "from": "TRO251", + "to": "TRO244", + "jamArea": "JA1301_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1301\".stJam1301_2" + }, + { + "from": "TRO243", + "to": "TRO244", + "jamArea": "JA1301_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1301\".stJam1301_2" + }, + { + "from": "TRO257", + "to": "TRO245", + "jamArea": "JA1302_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1302\".stJam1302_1" + }, + { + "from": "TRO254", + "to": "TRO246", + "jamArea": "JA1302_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1302\".stJam1302_2" + }, + { + "from": "TRO245", + "to": "TRO246", + "jamArea": "JA1302_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea1302\".stJam1302_2" + }, + { + "from": "TRO242", + "to": "TRO251", + "jamArea": "JA1303_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1303\".stJam1303_1" + }, + { + "from": "TRO253", + "to": "TRO251", + "jamArea": "JA1303_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1303\".stJam1303_1" + }, + { + "from": "TRO251", + "to": "TRO248", + "jamArea": "JA1303_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea1303\".stJam1303_2" + }, + { + "from": "TRO250", + "to": "TRO248", + "jamArea": "JA1303_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1303\".stJam1303_2" + }, + { + "from": "TRO241", + "to": "TRO242", + "jamArea": "JA1304_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1304\".stJam1304_1" + }, + { + "from": "TRO242", + "to": "TRO254", + "jamArea": "JA1304_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea1304\".stJam1304_2" + }, + { + "from": "TRO256", + "to": "TRO254", + "jamArea": "JA1304_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1304\".stJam1304_2" + }, + { + "from": "TRO254", + "to": "TRO257", + "jamArea": "JA1304_3", + "kind": "bypass", + "dbRef": "\"DB_JamArea1304\".stJam1304_3" + }, + { + "from": "TRO259", + "to": "TRO257", + "jamArea": "JA1304_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1304\".stJam1304_3" + }, + { + "from": "TRO243", + "to": "TRO249", + "jamArea": "JA1305_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1305\".stJam1305_1" + }, + { + "from": "TRO249", + "to": "TRO250", + "jamArea": "JA1305_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1305\".stJam1305_2" + }, + { + "from": "TRO244", + "to": "TRO252", + "jamArea": "JA1306_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1306\".stJam1306_1" + }, + { + "from": "TRO252", + "to": "TRO253", + "jamArea": "JA1306_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1306\".stJam1306_2" + }, + { + "from": "TRO246", + "to": "TRO255", + "jamArea": "JA1307_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1307\".stJam1307_1" + }, + { + "from": "TRO255", + "to": "TRO256", + "jamArea": "JA1307_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1307\".stJam1307_2" + }, + { + "from": "TRO245", + "to": "TRO258", + "jamArea": "JA1308_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1308\".stJam1308_1" + }, + { + "from": "TRO258", + "to": "TRO259", + "jamArea": "JA1308_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1308\".stJam1308_2" + }, + { + "from": "TRO240", + "to": "TRO241", + "jamArea": "JA1309_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1309\".stJam1309_2" + }, + { + "from": "TRO264", + "to": "TRO265", + "jamArea": "JA1401_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1401\".stJam1401_2" + }, + { + "from": "TRO262", + "to": "TRO263", + "jamArea": "JA1501_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1501\".stJam1501_2" + }, + { + "from": "TRO260", + "to": "TRO261", + "jamArea": "JA1601_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1601\".stJam1601_2" + } + ], + "externals": [ + { + "node": "TRO200", + "direction": "in", + "jamArea": "JA1109_1", + "dbRef": "\"DB_JamArea1109\".stJam1109_1" + }, + { + "node": "TRO220", + "direction": "in", + "jamArea": "JA1209_1", + "dbRef": "\"DB_JamArea1209\".stJam1209_1" + }, + { + "node": "TRO244", + "direction": "out", + "jamArea": "JA1302_3", + "dbRef": "\"DB_JamArea1302\".stJam1302_3" + }, + { + "node": "TRO246", + "direction": "out", + "jamArea": "JA1302_3", + "dbRef": "\"DB_JamArea1302\".stJam1302_3" + }, + { + "node": "TRO240", + "direction": "in", + "jamArea": "JA1309_1", + "dbRef": "\"DB_JamArea1309\".stJam1309_1" + }, + { + "node": "TRO264", + "direction": "in", + "jamArea": "JA1401_1", + "dbRef": "\"DB_JamArea1401\".stJam1401_1" + }, + { + "node": "TRO262", + "direction": "in", + "jamArea": "JA1501_1", + "dbRef": "\"DB_JamArea1501\".stJam1501_1" + }, + { + "node": "TRO260", + "direction": "in", + "jamArea": "JA1601_1", + "dbRef": "\"DB_JamArea1601\".stJam1601_1" + }, + { + "node": "TRO272", + "direction": "in", + "jamArea": "JA1801_1", + "dbRef": "\"DB_JamArea1801\".stJam1801_1" + }, + { + "node": "TRO270", + "direction": "in", + "jamArea": "JA4701_1", + "dbRef": "\"DB_JamArea4701\".stJam4701_1" + }, + { + "node": "TRO208", + "direction": "in", + "jamArea": "Storage1.1.1", + "dbRef": "Storage1.1.1" + }, + { + "node": "TRO211", + "direction": "in", + "jamArea": "Storage1.1.2", + "dbRef": "Storage1.1.2" + }, + { + "node": "TRO214", + "direction": "in", + "jamArea": "Storage1.1.3", + "dbRef": "Storage1.1.3" + }, + { + "node": "TRO217", + "direction": "in", + "jamArea": "Storage1.1.4", + "dbRef": "Storage1.1.4" + }, + { + "node": "TRO228", + "direction": "in", + "jamArea": "Storage1.2.1", + "dbRef": "Storage1.2.1" + }, + { + "node": "TRO231", + "direction": "in", + "jamArea": "Storage1.2.2", + "dbRef": "Storage1.2.2" + }, + { + "node": "TRO234", + "direction": "in", + "jamArea": "Storage1.2.3", + "dbRef": "Storage1.2.3" + }, + { + "node": "TRO237", + "direction": "in", + "jamArea": "Storage1.2.4", + "dbRef": "Storage1.2.4" + }, + { + "node": "TRO248", + "direction": "in", + "jamArea": "Storage1.3.1", + "dbRef": "Storage1.3.1" + }, + { + "node": "TRO251", + "direction": "in", + "jamArea": "Storage1.3.2", + "dbRef": "Storage1.3.2" + }, + { + "node": "TRO254", + "direction": "in", + "jamArea": "Storage1.3.3", + "dbRef": "Storage1.3.3" + }, + { + "node": "TRO257", + "direction": "in", + "jamArea": "Storage1.3.4", + "dbRef": "Storage1.3.4" + }, + { + "node": "TRO207", + "direction": "out", + "jamArea": "IO_Device_UH02_TO_UH01.stCARRIER_INFO", + "dbRef": "IO_Device_UH02_TO_UH01.stCARRIER_INFO" + }, + { + "node": "TRO227", + "direction": "out", + "jamArea": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_1", + "dbRef": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_1" + }, + { + "node": "TRO247", + "direction": "out", + "jamArea": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_2", + "dbRef": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_2" + } + ] + }, + "UH03": { + "nodes": { + "TRO300": { + "fbType": "Vario", + "comment": "TRO 300 (Vario)" + }, + "TRO301": { + "fbType": "1Sep", + "comment": "TRO 301(1Sep)" + }, + "TRO302": { + "fbType": "Vario", + "comment": "TRO 302 (Vario)" + }, + "TRO303": { + "fbType": "Vario", + "comment": "TRO 303 (Vario)" + }, + "TRO304": { + "fbType": "1Sep", + "comment": "TRO 304(1Sep)" + }, + "TRO305": { + "fbType": "Vario", + "comment": "TRO 305 (Vario)" + }, + "TRO306": { + "fbType": "Vario", + "comment": "TRO 306 (Vario)" + }, + "TRO307": { + "fbType": "Vario", + "comment": "TRO 307 (Vario)" + }, + "TRO308": { + "fbType": "Vario", + "comment": "TRO 308 (Vario)" + }, + "TRO309": { + "fbType": "1Sep", + "comment": "TRO 309 (1Sep)" + }, + "TRO310": { + "fbType": "1Sep", + "comment": "TRO 310 (1Sep)+Scanner (BX3102)" + }, + "TRO311": { + "fbType": "1Sep", + "comment": "TRO 311 (1Sep)+Scanner(BX3101)" + }, + "TRO312": { + "fbType": "1Sep", + "comment": "TRO 312 (1Sep)+Scanner(BX3100)" + }, + "TRO313": { + "fbType": "1Sep1Swi", + "comment": "TRO 313 (1Sep1Switch)+Scanner(BX3103)" + }, + "TRO314": { + "fbType": "1Sep1Swi", + "comment": "TRO 314 (1Sep1Switch)+Scanner(BX3104)" + }, + "TRO315": { + "fbType": "1Sep", + "comment": "TRO 315 (1Sep)" + }, + "TRO316": { + "fbType": "1Sep", + "comment": "TRO 316 (1Sep)" + }, + "TRO317": { + "fbType": "1Sep1Swi", + "comment": "TRO 317 (1Sep1Switch)+Scanner(BX3105)" + }, + "TRO318": { + "fbType": "1Sep1Swi", + "comment": "TRO 318 (1Sep1Switch) + Scanner(BX3106)" + }, + "TRO319": { + "fbType": "1Sep1Swi", + "comment": "TRO 319 (1Sep1Switch) + Scanner (BX3111)" + }, + "TRO320": { + "fbType": "1Sep1Swi", + "comment": "TRO 320 (1Sep1Switch) + Scanner(BX3112)" + }, + "TRO321": { + "fbType": "1Sep1Swi", + "comment": "TRO 321 (1Sep1Switch) + Scanner(BX3114)" + }, + "TRO322": { + "fbType": "1Sep1Swi", + "comment": "TRO 322 (1Sep1Switch)+Scanner(BX3113)" + }, + "TRO323": { + "fbType": "1Sep", + "comment": "TRO 323 (1Sep)" + }, + "TRO324": { + "fbType": "Vario", + "comment": "TRO 324 (Vario)" + }, + "TRO325": { + "fbType": "1Sep", + "comment": "TRO 325 (1Sep)" + }, + "TRO326": { + "fbType": "1Sep", + "comment": "TRO 326 (1Sep)" + }, + "TRO327": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO327" + }, + "TRO328": { + "fbType": "Vario", + "comment": "TRO 328 (Vario)" + }, + "TRO329": { + "fbType": "1Sep", + "comment": "TRO 329 (1Sep)" + }, + "TRO330": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO330" + }, + "TRO331": { + "fbType": "Vario", + "comment": "TRO 331 (Vario)" + }, + "TRO332": { + "fbType": "1Sep", + "comment": "TRO 332 (1Sep)" + }, + "TRO333": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO333" + }, + "TRO334": { + "fbType": "Vario", + "comment": "TRO 334 (Vario)" + }, + "TRO335": { + "fbType": "1Sep", + "comment": "TRO 335 (1Sep)" + }, + "TRO336": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO336" + }, + "TRO337": { + "fbType": "Vario", + "comment": "TRO 337 (Vario)" + }, + "TRO338": { + "fbType": "1Sep", + "comment": "TRO 338 (1Sep)" + }, + "TRO339": { + "fbType": "1Sep1Swi", + "comment": "TRO 339 (1Sep1Switch)+Scanner(BX3120)" + }, + "TRO340": { + "fbType": "1Sep1Swi", + "comment": "TRO 340 (1Sep1Switch)+Scanner(BX3121)" + }, + "TRO341": { + "fbType": "1Sep1Swi", + "comment": "TRO 341 (1Sep1Switch)+Scanner(BX3126)" + }, + "TRO342": { + "fbType": "1Sep1Swi", + "comment": "TRO 342 (1Sep1Switch)+Scanner(BX3127)" + }, + "TRO343": { + "fbType": "1Sep1Swi", + "comment": "TRO 343 (1Sep1Switch)+Scanner(BX3129)" + }, + "TRO344": { + "fbType": "1Sep1Swi", + "comment": "TRO 344 (1Sep1Switch)+Scanner(BX3128)" + }, + "TRO345": { + "fbType": "1Sep", + "comment": "TRO 345 (1Sep)" + }, + "TRO346": { + "fbType": "Vario", + "comment": "TRO 346 (Vario)" + }, + "TRO347": { + "fbType": "1Sep", + "comment": "TRO 347 (1Sep)" + }, + "TRO348": { + "fbType": "1Sep", + "comment": "TRO 348 (1Sep)" + }, + "TRO349": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO349" + }, + "TRO350": { + "fbType": "Vario", + "comment": "TRO 350 (Vario)" + }, + "TRO351": { + "fbType": "1Sep", + "comment": "TRO 351 (1Sep)" + }, + "TRO352": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO352" + }, + "TRO353": { + "fbType": "Vario", + "comment": "TRO 353 (Vario)" + }, + "TRO354": { + "fbType": "1Sep", + "comment": "TRO 354 (1Sep)" + }, + "TRO355": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO355" + }, + "TRO356": { + "fbType": "Vario", + "comment": "TRO 356 (Vario)" + }, + "TRO357": { + "fbType": "1Sep", + "comment": "TRO 357 (1Sep)" + }, + "TRO358": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO358" + }, + "TRO359": { + "fbType": "Vario", + "comment": "TRO 359 (Vario)" + }, + "TRO360": { + "fbType": "1Sep", + "comment": "TRO 360 (1Sep)" + }, + "TRO361": { + "fbType": "1Sep1Swi", + "comment": "TRO 361 (1Sep1Switch)+Scanner(BX3131)" + }, + "TRO362": { + "fbType": "1Sep1Swi", + "comment": "TRO 362 (1Sep1Switch)+Scanner(BX3132)" + }, + "TRO363": { + "fbType": "1Sep1Swi", + "comment": "TRO 363 (1Sep1Switch)+Scanner(BX3137)" + }, + "TRO364": { + "fbType": "1Sep1Swi", + "comment": "TRO 364 (1Sep1Switch)+Scanner(BX3138)" + }, + "TRO365": { + "fbType": "1Sep1Swi", + "comment": "TRO 365 (1Sep1Switch)+Scanner(BX3140)" + }, + "TRO366": { + "fbType": "1Sep1Swi", + "comment": "TRO 366 (1Sep1Switch)+Scanner(BX3139)" + }, + "TRO367": { + "fbType": "1Sep", + "comment": "TRO 367 (1Sep)" + }, + "TRO368": { + "fbType": "Vario", + "comment": "TRO 368 (Vario, from Lvl1)" + }, + "TRO369": { + "fbType": "1Sep", + "comment": "TRO 369 (1Sep)" + }, + "TRO370": { + "fbType": "1Sep", + "comment": "TRO 370 (1Sep)" + }, + "TRO371": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO371" + }, + "TRO372": { + "fbType": "Vario", + "comment": "TRO 372 (Vario)" + }, + "TRO373": { + "fbType": "1Sep", + "comment": "TRO 373 (1Sep)" + }, + "TRO374": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO374" + }, + "TRO375": { + "fbType": "Vario", + "comment": "TRO 375 (Vario)" + }, + "TRO376": { + "fbType": "1Sep", + "comment": "TRO 376 (1Sep)" + }, + "TRO377": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO377" + }, + "TRO378": { + "fbType": "Vario", + "comment": "TRO 378 (Vario)" + }, + "TRO379": { + "fbType": "1Sep", + "comment": "TRO 379 (1Sep)" + }, + "TRO380": { + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO380" + }, + "TRO381": { + "fbType": "Vario", + "comment": "TRO 381 (Vario)" + }, + "TRO382": { + "fbType": "1Sep", + "comment": "TRO 382 (1Sep)" + }, + "TRO386": { + "fbType": "1Sep", + "comment": "TRO 386 (1Sep) - kam später dazu" + } + }, + "connections": [ + { + "from": "TRO318", + "to": "TRO330", + "jamArea": "JA2101_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2101\".stJam2101_1" + }, + { + "from": "TRO332", + "to": "TRO330", + "jamArea": "JA2101_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2101\".stJam2101_1" + }, + { + "from": "TRO330", + "to": "TRO327", + "jamArea": "JA2101_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea2101\".stJam2101_2" + }, + { + "from": "TRO329", + "to": "TRO327", + "jamArea": "JA2101_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2101\".stJam2101_2" + }, + { + "from": "TRO315", + "to": "TRO317", + "jamArea": "JA2102_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2102\".stJam2102_1" + }, + { + "from": "TRO317", + "to": "TRO318", + "jamArea": "JA2102_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2102\".stJam2102_2" + }, + { + "from": "TRO318", + "to": "TRO333", + "jamArea": "JA2102_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2102\".stJam2102_3" + }, + { + "from": "TRO335", + "to": "TRO333", + "jamArea": "JA2102_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2102\".stJam2102_3" + }, + { + "from": "TRO333", + "to": "TRO336", + "jamArea": "JA2102_4", + "kind": "bypass", + "dbRef": "\"DB_JamArea2102\".stJam2102_4" + }, + { + "from": "TRO338", + "to": "TRO336", + "jamArea": "JA2102_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2102\".stJam2102_4" + }, + { + "from": "TRO327", + "to": "TRO319", + "jamArea": "JA2103_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2103\".stJam2103_1" + }, + { + "from": "TRO330", + "to": "TRO320", + "jamArea": "JA2103_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2103\".stJam2103_2" + }, + { + "from": "TRO319", + "to": "TRO320", + "jamArea": "JA2103_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea2103\".stJam2103_2" + }, + { + "from": "TRO336", + "to": "TRO321", + "jamArea": "JA2104_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_1" + }, + { + "from": "TRO333", + "to": "TRO322", + "jamArea": "JA2104_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_2" + }, + { + "from": "TRO321", + "to": "TRO322", + "jamArea": "JA2104_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_2" + }, + { + "from": "TRO320", + "to": "TRO323", + "jamArea": "JA2104_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea2104\".stJam2104_3" + }, + { + "from": "TRO322", + "to": "TRO323", + "jamArea": "JA2104_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_3" + }, + { + "from": "TRO323", + "to": "TRO326", + "jamArea": "JA2104_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_4" + }, + { + "from": "TRO325", + "to": "TRO326", + "jamArea": "JA2104_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_4" + }, + { + "from": "TRO319", + "to": "TRO328", + "jamArea": "JA2105_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2105\".stJam2105_1" + }, + { + "from": "TRO328", + "to": "TRO329", + "jamArea": "JA2105_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2105\".stJam2105_2" + }, + { + "from": "TRO320", + "to": "TRO331", + "jamArea": "JA2106_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2106\".stJam2106_1" + }, + { + "from": "TRO331", + "to": "TRO332", + "jamArea": "JA2106_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2106\".stJam2106_2" + }, + { + "from": "TRO322", + "to": "TRO334", + "jamArea": "JA2107_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2107\".stJam2107_1" + }, + { + "from": "TRO334", + "to": "TRO335", + "jamArea": "JA2107_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2107\".stJam2107_2" + }, + { + "from": "TRO321", + "to": "TRO337", + "jamArea": "JA2108_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2108\".stJam2108_1" + }, + { + "from": "TRO337", + "to": "TRO338", + "jamArea": "JA2108_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2108\".stJam2108_2" + }, + { + "from": "TRO324", + "to": "TRO325", + "jamArea": "JA2109_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2109\".stJam2109_2" + }, + { + "from": "TRO386", + "to": "TRO310", + "jamArea": "JA2110_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2110\".stJam2110_1" + }, + { + "from": "TRO310", + "to": "TRO313", + "jamArea": "JA2110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2110\".stJam2110_2" + }, + { + "from": "TRO311", + "to": "TRO313", + "jamArea": "JA2110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2110\".stJam2110_2" + }, + { + "from": "TRO312", + "to": "TRO313", + "jamArea": "JA2110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2110\".stJam2110_2" + }, + { + "from": "TRO313", + "to": "TRO314", + "jamArea": "JA2110_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea2110\".stJam2110_3" + }, + { + "from": "TRO314", + "to": "TRO315", + "jamArea": "JA2110_4", + "kind": "dir2", + "dbRef": "\"DB_JamArea2110\".stJam2110_4" + }, + { + "from": "TRO309", + "to": "TRO386", + "jamArea": "JA2110_5", + "kind": "normal", + "dbRef": "\"DB_JamArea2110\".stJam2110_5" + }, + { + "from": "TRO308", + "to": "TRO309", + "jamArea": "JA2111_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2111\".stJam2111_2" + }, + { + "from": "TRO313", + "to": "TRO316", + "jamArea": "JA2112_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2112\".stJam2112_1" + }, + { + "from": "TRO340", + "to": "TRO352", + "jamArea": "JA2201_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2201\".stJam2201_1" + }, + { + "from": "TRO354", + "to": "TRO352", + "jamArea": "JA2201_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2201\".stJam2201_1" + }, + { + "from": "TRO352", + "to": "TRO349", + "jamArea": "JA2201_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea2201\".stJam2201_2" + }, + { + "from": "TRO351", + "to": "TRO349", + "jamArea": "JA2201_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2201\".stJam2201_2" + }, + { + "from": "TRO314", + "to": "TRO339", + "jamArea": "JA2202_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2202\".stJam2202_1" + }, + { + "from": "TRO339", + "to": "TRO340", + "jamArea": "JA2202_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2202\".stJam2202_2" + }, + { + "from": "TRO340", + "to": "TRO355", + "jamArea": "JA2202_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2202\".stJam2202_3" + }, + { + "from": "TRO357", + "to": "TRO355", + "jamArea": "JA2202_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2202\".stJam2202_3" + }, + { + "from": "TRO355", + "to": "TRO358", + "jamArea": "JA2202_4", + "kind": "bypass", + "dbRef": "\"DB_JamArea2202\".stJam2202_4" + }, + { + "from": "TRO360", + "to": "TRO358", + "jamArea": "JA2202_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2202\".stJam2202_4" + }, + { + "from": "TRO349", + "to": "TRO341", + "jamArea": "JA2203_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2203\".stJam2203_1" + }, + { + "from": "TRO352", + "to": "TRO342", + "jamArea": "JA2203_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2203\".stJam2203_2" + }, + { + "from": "TRO341", + "to": "TRO342", + "jamArea": "JA2203_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea2203\".stJam2203_2" + }, + { + "from": "TRO358", + "to": "TRO343", + "jamArea": "JA2204_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_1" + }, + { + "from": "TRO355", + "to": "TRO344", + "jamArea": "JA2204_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_2" + }, + { + "from": "TRO343", + "to": "TRO344", + "jamArea": "JA2204_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_2" + }, + { + "from": "TRO342", + "to": "TRO345", + "jamArea": "JA2204_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea2204\".stJam2204_3" + }, + { + "from": "TRO344", + "to": "TRO345", + "jamArea": "JA2204_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_3" + }, + { + "from": "TRO345", + "to": "TRO348", + "jamArea": "JA2204_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_4" + }, + { + "from": "TRO347", + "to": "TRO348", + "jamArea": "JA2204_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_4" + }, + { + "from": "TRO341", + "to": "TRO350", + "jamArea": "JA2205_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2205\".stJam2205_1" + }, + { + "from": "TRO350", + "to": "TRO351", + "jamArea": "JA2205_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2205\".stJam2205_2" + }, + { + "from": "TRO342", + "to": "TRO353", + "jamArea": "JA2206_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2206\".stJam2206_1" + }, + { + "from": "TRO353", + "to": "TRO354", + "jamArea": "JA2206_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2206\".stJam2206_2" + }, + { + "from": "TRO344", + "to": "TRO356", + "jamArea": "JA2207_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2207\".stJam2207_1" + }, + { + "from": "TRO356", + "to": "TRO357", + "jamArea": "JA2207_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2207\".stJam2207_2" + }, + { + "from": "TRO343", + "to": "TRO359", + "jamArea": "JA2208_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2208\".stJam2208_1" + }, + { + "from": "TRO359", + "to": "TRO360", + "jamArea": "JA2208_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2208\".stJam2208_2" + }, + { + "from": "TRO346", + "to": "TRO347", + "jamArea": "JA2209_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2209\".stJam2209_2" + }, + { + "from": "TRO371", + "to": "TRO363", + "jamArea": "JA2301_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2301\".stJam2301_1" + }, + { + "from": "TRO374", + "to": "TRO364", + "jamArea": "JA2301_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2301\".stJam2301_2" + }, + { + "from": "TRO363", + "to": "TRO364", + "jamArea": "JA2301_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2301\".stJam2301_2" + }, + { + "from": "TRO380", + "to": "TRO365", + "jamArea": "JA2302_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2302\".stJam2302_1" + }, + { + "from": "TRO377", + "to": "TRO366", + "jamArea": "JA2302_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2302\".stJam2302_2" + }, + { + "from": "TRO365", + "to": "TRO366", + "jamArea": "JA2302_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea2302\".stJam2302_2" + }, + { + "from": "TRO364", + "to": "TRO367", + "jamArea": "JA2302_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2302\".stJam2302_3" + }, + { + "from": "TRO366", + "to": "TRO367", + "jamArea": "JA2302_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea2302\".stJam2302_3" + }, + { + "from": "TRO367", + "to": "TRO370", + "jamArea": "JA2302_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2302\".stJam2302_4" + }, + { + "from": "TRO369", + "to": "TRO370", + "jamArea": "JA2302_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2302\".stJam2302_4" + }, + { + "from": "TRO362", + "to": "TRO374", + "jamArea": "JA2303_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2303\".stJam2303_1" + }, + { + "from": "TRO376", + "to": "TRO374", + "jamArea": "JA2303_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2303\".stJam2303_1" + }, + { + "from": "TRO374", + "to": "TRO371", + "jamArea": "JA2303_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea2303\".stJam2303_2" + }, + { + "from": "TRO373", + "to": "TRO371", + "jamArea": "JA2303_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2303\".stJam2303_2" + }, + { + "from": "TRO316", + "to": "TRO361", + "jamArea": "JA2304_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2304\".stJam2304_1" + }, + { + "from": "TRO361", + "to": "TRO362", + "jamArea": "JA2304_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea2304\".stJam2304_2" + }, + { + "from": "TRO362", + "to": "TRO377", + "jamArea": "JA2304_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea2304\".stJam2304_3" + }, + { + "from": "TRO379", + "to": "TRO377", + "jamArea": "JA2304_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2304\".stJam2304_3" + }, + { + "from": "TRO377", + "to": "TRO380", + "jamArea": "JA2304_4", + "kind": "bypass", + "dbRef": "\"DB_JamArea2304\".stJam2304_4" + }, + { + "from": "TRO382", + "to": "TRO380", + "jamArea": "JA2304_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2304\".stJam2304_4" + }, + { + "from": "TRO363", + "to": "TRO372", + "jamArea": "JA2305_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2305\".stJam2305_1" + }, + { + "from": "TRO372", + "to": "TRO373", + "jamArea": "JA2305_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2305\".stJam2305_2" + }, + { + "from": "TRO364", + "to": "TRO375", + "jamArea": "JA2306_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2306\".stJam2306_1" + }, + { + "from": "TRO375", + "to": "TRO376", + "jamArea": "JA2306_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2306\".stJam2306_2" + }, + { + "from": "TRO366", + "to": "TRO378", + "jamArea": "JA2307_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2307\".stJam2307_1" + }, + { + "from": "TRO378", + "to": "TRO379", + "jamArea": "JA2307_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2307\".stJam2307_2" + }, + { + "from": "TRO365", + "to": "TRO381", + "jamArea": "JA2308_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2308\".stJam2308_1" + }, + { + "from": "TRO381", + "to": "TRO382", + "jamArea": "JA2308_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2308\".stJam2308_2" + }, + { + "from": "TRO368", + "to": "TRO369", + "jamArea": "JA2309_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2309\".stJam2309_2" + }, + { + "from": "TRO300", + "to": "TRO302", + "jamArea": "JA4101_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4101\".stJam4101_1" + }, + { + "from": "TRO301", + "to": "TRO302", + "jamArea": "JA4101_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4101\".stJam4101_1" + }, + { + "from": "TRO302", + "to": "TRO311", + "jamArea": "JA4101_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4101\".stJam4101_2" + }, + { + "from": "TRO303", + "to": "TRO305", + "jamArea": "JA4201_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4201\".stJam4201_1" + }, + { + "from": "TRO304", + "to": "TRO305", + "jamArea": "JA4201_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4201\".stJam4201_1" + }, + { + "from": "TRO305", + "to": "TRO312", + "jamArea": "JA4201_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4201\".stJam4201_2" + } + ], + "externals": [ + { + "node": "TRO336", + "direction": "out", + "jamArea": "JA2102_5", + "dbRef": "\"DB_JamArea2102\".stJam2102_5" + }, + { + "node": "TRO324", + "direction": "in", + "jamArea": "JA2109_1", + "dbRef": "\"DB_JamArea2109\".stJam2109_1" + }, + { + "node": "TRO308", + "direction": "in", + "jamArea": "JA2111_1", + "dbRef": "\"DB_JamArea2111\".stJam2111_1" + }, + { + "node": "TRO358", + "direction": "out", + "jamArea": "JA2202_5", + "dbRef": "\"DB_JamArea2202\".stJam2202_5" + }, + { + "node": "TRO346", + "direction": "in", + "jamArea": "JA2209_1", + "dbRef": "\"DB_JamArea2209\".stJam2209_1" + }, + { + "node": "TRO368", + "direction": "in", + "jamArea": "JA2309_1", + "dbRef": "\"DB_JamArea2309\".stJam2309_1" + }, + { + "node": "TRO300", + "direction": "in", + "jamArea": "JA4102_1", + "dbRef": "\"DB_JamArea4102\".stJam4102_1" + }, + { + "node": "TRO301", + "direction": "in", + "jamArea": "JA4102_2", + "dbRef": "\"DB_JamArea4102\".stJam4102_2" + }, + { + "node": "TRO303", + "direction": "in", + "jamArea": "JA4202_1", + "dbRef": "\"DB_JamArea4202\".stJam4202_1" + }, + { + "node": "TRO304", + "direction": "in", + "jamArea": "JA4202_2", + "dbRef": "\"DB_JamArea4202\".stJam4202_2" + }, + { + "node": "TRO306", + "direction": "in", + "jamArea": "JA4301_1", + "dbRef": "\"DB_JamArea4301\".stJam4301_1" + }, + { + "node": "TRO307", + "direction": "in", + "jamArea": "JA4401_1", + "dbRef": "\"DB_JamArea4401\".stJam4401_1" + }, + { + "node": "TRO327", + "direction": "in", + "jamArea": "Storage2.1.1", + "dbRef": "Storage2.1.1" + }, + { + "node": "TRO330", + "direction": "in", + "jamArea": "Storage2.1.2", + "dbRef": "Storage2.1.2" + }, + { + "node": "TRO333", + "direction": "in", + "jamArea": "Storage2.1.3", + "dbRef": "Storage2.1.3" + }, + { + "node": "TRO336", + "direction": "in", + "jamArea": "Storage2.1.4", + "dbRef": "Storage2.1.4" + }, + { + "node": "TRO349", + "direction": "in", + "jamArea": "Storage2.2.1", + "dbRef": "Storage2.2.1" + }, + { + "node": "TRO352", + "direction": "in", + "jamArea": "Storage2.2.2", + "dbRef": "Storage2.2.2" + }, + { + "node": "TRO355", + "direction": "in", + "jamArea": "Storage2.2.3", + "dbRef": "Storage2.2.3" + }, + { + "node": "TRO358", + "direction": "in", + "jamArea": "Storage2.2.4", + "dbRef": "Storage2.2.4" + }, + { + "node": "TRO371", + "direction": "in", + "jamArea": "Storage2.3.1", + "dbRef": "Storage2.3.1" + }, + { + "node": "TRO374", + "direction": "in", + "jamArea": "Storage2.3.2", + "dbRef": "Storage2.3.2" + }, + { + "node": "TRO377", + "direction": "in", + "jamArea": "Storage2.3.3", + "dbRef": "Storage2.3.3" + }, + { + "node": "TRO380", + "direction": "in", + "jamArea": "Storage2.3.4", + "dbRef": "Storage2.3.4" + }, + { + "node": "TRO326", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCARRIER_INFO", + "dbRef": "IO_Device_UH03_TO_UH01.stCARRIER_INFO" + }, + { + "node": "TRO348", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_1", + "dbRef": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_1" + }, + { + "node": "TRO370", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_2", + "dbRef": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_2" + }, + { + "node": "TRO317", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCarrierL2toL1", + "dbRef": "IO_Device_UH03_TO_UH01.stCarrierL2toL1" + }, + { + "node": "TRO339", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_2", + "dbRef": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_2" + }, + { + "node": "TRO361", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_3", + "dbRef": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_3" + } + ] + }, + "UH04": { + "nodes": { + "TRO400": { + "fbType": "Vario", + "comment": "TRO 400 (Vario)" + }, + "TRO401": { + "fbType": "Vario", + "comment": "TRO 401 (Vario)" + }, + "TRO402": { + "fbType": "1Sep", + "comment": "TRO 402 (1Sep) (Vor Brandschutztor)" + }, + "TRO403": { + "fbType": "Vario", + "comment": "TRO 403 (Vario)" + }, + "TRO404": { + "fbType": "1Sep", + "comment": "TRO 404 (1Sep)" + }, + "TRO405": { + "fbType": "1Sep1Swi", + "comment": "TRO 405 (1Sep1Switch) + Scanner (BX4100) + Behangskontrolle" + }, + "TRO406": { + "fbType": "1Sep", + "comment": "TRO 406 (1Sep) + Scanner (BX4101)" + }, + "TRO407": { + "fbType": "1Sep1Swi", + "comment": "TRO 407 (1Sep1Switch) + Scanner (BX4102)" + }, + "TRO408": { + "fbType": "Vario", + "comment": "TRO 408 (Vario)" + }, + "TRO409": { + "fbType": "1Sep", + "comment": "TRO 409 (1Sep)" + }, + "TRO410": { + "fbType": "1Sep1Swi", + "comment": "TRO 410 (1Sep1Switch) + Scanner (BX4104)" + }, + "TRO411": { + "fbType": "Vario", + "comment": "TRO 411 (Vario)" + }, + "TRO412": { + "fbType": "1Sep", + "comment": "TRO 412 (1Sep)" + }, + "TRO413": { + "fbType": "1Sep1Swi", + "comment": "TRO 413(1Sep1Switch)+Scanner(BX4106)" + }, + "TRO414": { + "fbType": "Vario", + "comment": "TRO 414 (Vario)" + }, + "TRO415": { + "fbType": "1Sep", + "comment": "TRO 415 (1Sep)" + }, + "TRO416": { + "fbType": "1Sep", + "comment": "TRO 416 (1Sep) + Beladeprüfung" + }, + "TRO417": { + "fbType": "1Sep", + "comment": "TRO 417 (1Sep)" + }, + "TRO418": { + "fbType": "Vario", + "comment": "TRO 418 (Vario)" + }, + "TRO420": { + "fbType": "Vario", + "comment": "TRO 420 (Vario)" + }, + "TRO421": { + "fbType": "Vario_workStation", + "comment": "TRO 421 (Vario)" + }, + "TRO422": { + "fbType": "Vario_workStation", + "comment": "TRO 422 (Vario)" + }, + "TRO423": { + "fbType": "Vario_workStation", + "comment": "TRO 423 (Vario)" + }, + "TRO424": { + "fbType": "1Sep", + "comment": "TRO 424 (1Sep) vor Behangskontrolle" + } + }, + "connections": [ + { + "from": "TRO400", + "to": "TRO401", + "jamArea": "JA4001_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4001\".stJam4001_1" + }, + { + "from": "TRO401", + "to": "TRO402", + "jamArea": "JA4001_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4001\".stJam4001_2" + }, + { + "from": "TRO402", + "to": "TRO403", + "jamArea": "JA4002_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4002\".stJam4002_1" + }, + { + "from": "TRO403", + "to": "TRO404", + "jamArea": "JA4002_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4002\".stJam4002_2" + }, + { + "from": "TRO424", + "to": "TRO405", + "jamArea": "JA4003_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_1" + }, + { + "from": "TRO405", + "to": "TRO406", + "jamArea": "JA4003_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea4003\".stJam4003_2" + }, + { + "from": "TRO406", + "to": "TRO407", + "jamArea": "JA4003_3", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_3" + }, + { + "from": "TRO407", + "to": "TRO410", + "jamArea": "JA4003_4", + "kind": "dir2", + "dbRef": "\"DB_JamArea4003\".stJam4003_4" + }, + { + "from": "TRO409", + "to": "TRO410", + "jamArea": "JA4003_4", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_4" + }, + { + "from": "TRO410", + "to": "TRO413", + "jamArea": "JA4003_5", + "kind": "dir2", + "dbRef": "\"DB_JamArea4003\".stJam4003_5" + }, + { + "from": "TRO412", + "to": "TRO413", + "jamArea": "JA4003_5", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_5" + }, + { + "from": "TRO413", + "to": "TRO416", + "jamArea": "JA4003_6", + "kind": "dir2", + "dbRef": "\"DB_JamArea4003\".stJam4003_6" + }, + { + "from": "TRO415", + "to": "TRO416", + "jamArea": "JA4003_6", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_6" + }, + { + "from": "TRO416", + "to": "TRO417", + "jamArea": "JA4003_7", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_7" + }, + { + "from": "TRO404", + "to": "TRO424", + "jamArea": "JA4003_8", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_8" + }, + { + "from": "TRO417", + "to": "TRO424", + "jamArea": "JA4003_8", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_8" + }, + { + "from": "TRO407", + "to": "TRO408", + "jamArea": "JA4004_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4004\".stJam4004_1" + }, + { + "from": "TRO408", + "to": "TRO421", + "jamArea": "JA4004_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4004\".stJam4004_2" + }, + { + "from": "TRO410", + "to": "TRO411", + "jamArea": "JA4006_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4006\".stJam4006_1" + }, + { + "from": "TRO411", + "to": "TRO422", + "jamArea": "JA4006_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4006\".stJam4006_2" + }, + { + "from": "TRO422", + "to": "TRO412", + "jamArea": "JA4007_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4007\".stJam4007_1" + }, + { + "from": "TRO413", + "to": "TRO414", + "jamArea": "JA4008_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4008\".stJam4008_1" + }, + { + "from": "TRO414", + "to": "TRO423", + "jamArea": "JA4008_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4008\".stJam4008_2" + }, + { + "from": "TRO423", + "to": "TRO415", + "jamArea": "JA4009_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4009\".stJam4009_1" + }, + { + "from": "TRO418", + "to": "TRO420", + "jamArea": "JA4011_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4011\".stJam4011_1" + } + ], + "externals": [ + { + "node": "TRO400", + "direction": "in", + "jamArea": "JA4000_1", + "dbRef": "\"DB_JamArea4000\".stJam4000_1" + }, + { + "node": "TRO421", + "direction": "out", + "jamArea": "JA4005_1", + "dbRef": "\"DB_JamArea4005\".stJam4005_1" + }, + { + "node": "TRO418", + "direction": "in", + "jamArea": "JA4010_1", + "dbRef": "\"DB_JamArea4010\".stJam4010_1" + } + ] + }, + "UH05": { + "nodes": { + "TRO500": { + "fbType": "Vario", + "comment": "TRO 500 (Vario) - Stand: Vorbereitet für Umbau!" + }, + "TRO501": { + "fbType": "1Sep", + "comment": "TRO 501 (1Sep) + Scanner (BX5101)" + }, + "TRO502": { + "fbType": "Vario", + "comment": "TRO 502 (Vario) - Stand: Vorbereitet für Umbau!" + }, + "TRO503": { + "fbType": "1Sep", + "comment": "TRO 503 (1Sep)+ Scanner (BX5100)" + }, + "TRO504": { + "fbType": "1Sep", + "comment": "TRO 504 (1Sep)" + }, + "TRO505": { + "fbType": "1Sep1Swi", + "comment": "TRO 505 (1Sep1Switch) + Scanner (BX5102)" + }, + "TRO506": { + "fbType": "Vario", + "comment": "TRO 506 (Vario)" + }, + "TRO507": { + "fbType": "1Sep", + "comment": "TRO 507 (1Sep)" + }, + "TRO508": { + "fbType": "Vario", + "comment": "TRO 508 (Vario)+Scanner(BX5103)" + }, + "TRO509": { + "fbType": "1Sep", + "comment": "TRO 509 (1Sep)" + }, + "TRO510": { + "fbType": "1Sep1Swi", + "comment": "TRO 510 (1Sep1Switch) + Scanner (BX5104)" + }, + "TRO511": { + "fbType": "1Sep", + "comment": "TRO 511 (1Sep)" + }, + "TRO512": { + "fbType": "Vario", + "comment": "TRO 512 (Vario)+Scanner(BX5105)" + }, + "TRO513": { + "fbType": "1Sep", + "comment": "TRO 513 (1Sep)" + }, + "TRO514": { + "fbType": "1Sep1Swi", + "comment": "TRO 514 (1Sep1Switch) + Scanner (BX5106)" + }, + "TRO515": { + "fbType": "1Sep", + "comment": "TRO 515 (1Sep)" + }, + "TRO516": { + "fbType": "Vario", + "comment": "TRO 516(Vario)+Scanner(BX5107)" + }, + "TRO517": { + "fbType": "1Sep", + "comment": "TRO 517 (1Sep)" + }, + "TRO518": { + "fbType": "1Sep1Swi", + "comment": "TRO 518 (1Sep1Switch) + Scanner (BX5108)" + }, + "TRO519": { + "fbType": "1Sep", + "comment": "TRO 519 (1Sep)" + }, + "TRO520": { + "fbType": "Vario", + "comment": "TRO 520 (Vario)+Scanner(BX5109)" + }, + "TRO521": { + "fbType": "1Sep", + "comment": "TRO 521(1Sep)" + }, + "TRO522": { + "fbType": "1Sep1Swi", + "comment": "TRO 522 (1Sep1Switch) + Scanner (BX5110)" + }, + "TRO523": { + "fbType": "1Sep", + "comment": "TRO 523 (1Sep)" + }, + "TRO524": { + "fbType": "Vario", + "comment": "TRO 524 (Vario)+Scanner(BX5231)" + }, + "TRO525": { + "fbType": "1Sep", + "comment": "TRO 525(1Sep)" + }, + "TRO526": { + "fbType": "1Sep", + "comment": "TRO 526 (1Sep) + Scanner (BX5112)" + }, + "TRO527": { + "fbType": "1Sep1Swi", + "comment": "TRO 527 (1Sep1Switch)" + }, + "TRO528": { + "fbType": "1Sep", + "comment": "TRO 528 (1Sep)" + }, + "TRO529": { + "fbType": "1Sep", + "comment": "TRO 529 (1Sep) + Scanner (BX5113)" + }, + "TRO530": { + "fbType": "Vario", + "comment": "TRO 530 (Vario)" + }, + "TRO531": { + "fbType": "Vario", + "comment": "TRO 531 (Vario)" + } + }, + "connections": [ + { + "from": "TRO502", + "to": "TRO531", + "jamArea": "JA5000_2", + "kind": "finger", + "dbRef": "\"DB_JamArea5000\".stJam5000_2" + }, + { + "from": "TRO531", + "to": "TRO503", + "jamArea": "JA5000_3", + "kind": "finger", + "dbRef": "\"DB_JamArea5000\".stJam5000_3" + }, + { + "from": "TRO500", + "to": "TRO530", + "jamArea": "JA5001_2", + "kind": "finger", + "dbRef": "\"DB_JamArea5001\".stJam5001_2" + }, + { + "from": "TRO530", + "to": "TRO501", + "jamArea": "JA5001_3", + "kind": "finger", + "dbRef": "\"DB_JamArea5001\".stJam5001_3" + }, + { + "from": "TRO501", + "to": "TRO504", + "jamArea": "JA5002_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_1" + }, + { + "from": "TRO503", + "to": "TRO504", + "jamArea": "JA5002_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_1" + }, + { + "from": "TRO529", + "to": "TRO504", + "jamArea": "JA5002_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_1" + }, + { + "from": "TRO528", + "to": "TRO529", + "jamArea": "JA5002_10", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_10" + }, + { + "from": "TRO504", + "to": "TRO505", + "jamArea": "JA5002_2", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_2" + }, + { + "from": "TRO505", + "to": "TRO510", + "jamArea": "JA5002_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_3" + }, + { + "from": "TRO509", + "to": "TRO510", + "jamArea": "JA5002_3", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_3" + }, + { + "from": "TRO510", + "to": "TRO514", + "jamArea": "JA5002_4", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_4" + }, + { + "from": "TRO513", + "to": "TRO514", + "jamArea": "JA5002_4", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_4" + }, + { + "from": "TRO514", + "to": "TRO518", + "jamArea": "JA5002_5", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_5" + }, + { + "from": "TRO517", + "to": "TRO518", + "jamArea": "JA5002_5", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_5" + }, + { + "from": "TRO518", + "to": "TRO522", + "jamArea": "JA5002_6", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_6" + }, + { + "from": "TRO521", + "to": "TRO522", + "jamArea": "JA5002_6", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_6" + }, + { + "from": "TRO522", + "to": "TRO526", + "jamArea": "JA5002_7", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_7" + }, + { + "from": "TRO525", + "to": "TRO526", + "jamArea": "JA5002_7", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_7" + }, + { + "from": "TRO526", + "to": "TRO527", + "jamArea": "JA5002_8", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_8" + }, + { + "from": "TRO527", + "to": "TRO528", + "jamArea": "JA5002_9", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_9" + }, + { + "from": "TRO505", + "to": "TRO506", + "jamArea": "JA5003_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5003\".stJam5003_1" + }, + { + "from": "TRO506", + "to": "TRO507", + "jamArea": "JA5003_2", + "kind": "finger", + "dbRef": "\"DB_JamArea5003\".stJam5003_2" + }, + { + "from": "TRO507", + "to": "TRO508", + "jamArea": "JA5004_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5004\".stJam5004_1" + }, + { + "from": "TRO510", + "to": "TRO511", + "jamArea": "JA5005_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5005\".stJam5005_1" + }, + { + "from": "TRO511", + "to": "TRO512", + "jamArea": "JA5005_2", + "kind": "normal", + "dbRef": "\"DB_JamArea5005\".stJam5005_2" + }, + { + "from": "TRO514", + "to": "TRO515", + "jamArea": "JA5006_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5006\".stJam5006_1" + }, + { + "from": "TRO515", + "to": "TRO516", + "jamArea": "JA5006_2", + "kind": "normal", + "dbRef": "\"DB_JamArea5006\".stJam5006_2" + }, + { + "from": "TRO518", + "to": "TRO519", + "jamArea": "JA5007_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5007\".stJam5007_1" + }, + { + "from": "TRO519", + "to": "TRO520", + "jamArea": "JA5007_2", + "kind": "normal", + "dbRef": "\"DB_JamArea5007\".stJam5007_2" + }, + { + "from": "TRO522", + "to": "TRO523", + "jamArea": "JA5008_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5008\".stJam5008_1" + }, + { + "from": "TRO523", + "to": "TRO524", + "jamArea": "JA5008_2", + "kind": "normal", + "dbRef": "\"DB_JamArea5008\".stJam5008_2" + } + ], + "externals": [ + { + "node": "TRO502", + "direction": "in", + "jamArea": "JA5000_1", + "dbRef": "\"DB_JamArea5000\".stJam5000_1" + }, + { + "node": "TRO500", + "direction": "in", + "jamArea": "JA5001_1", + "dbRef": "\"DB_JamArea5001\".stJam5001_1" + }, + { + "node": "TRO508", + "direction": "out", + "jamArea": "JA5004_2", + "dbRef": "\"DB_JamArea5004\".stJam5004_2" + }, + { + "node": "TRO512", + "direction": "out", + "jamArea": "JA5005_3", + "dbRef": "\"DB_JamArea5005\".stJam5005_3" + }, + { + "node": "TRO516", + "direction": "out", + "jamArea": "JA5006_3", + "dbRef": "\"DB_JamArea5006\".stJam5006_3" + }, + { + "node": "TRO520", + "direction": "out", + "jamArea": "JA5007_3", + "dbRef": "\"DB_JamArea5007\".stJam5007_3" + }, + { + "node": "TRO524", + "direction": "out", + "jamArea": "JA5008_3", + "dbRef": "\"DB_JamArea5008\".stJam5008_3" + } + ] + } + } +} diff --git a/doc/EA-Listen-Analyse.md b/doc/EA-Listen-Analyse.md new file mode 100644 index 0000000..aa50e2b --- /dev/null +++ b/doc/EA-Listen-Analyse.md @@ -0,0 +1,141 @@ +# Analyse der Ein-/Ausgabelisten (data/Eingaben) + +## Kontext + +In `data/Eingaben/` liegen je Steuerung (ILS-1 bis ILS-5, entspricht UH01-UH05) drei Excel-Dateien mit denselben E/A-Punkten in drei Sichten: + +| Datei | Inhalt | +| --- | --- | +| `..._EA.xlsx` | Rohliste: Adresse (`E000.0`), Kommentar, Zeilenreferenz (Schaltplan) | +| `..._TIA.xlsx` | Import-Liste fuers TIA Portal: Blatt "PLC Tags" (BMK-Name, `Data Type`, `%E`/`%A`-Logikadresse, Kommentar, HMI-Flags) + Blatt "Constants" (`cIn`-Indexkonstanten) | +| `..._WSCAD.xlsx` | Import-Liste fuers WSCAD (E-CAD): Anschluss, Kommentar, **Bezug** (Ortskennzeichen, z.B. `=A01+UC2101-KF1DI1`) | + +Alle Signale sind **Bool** (reine Digital-E/A-Listen). Analogwerte (Tilt-/Distanzsensoren), PROFINET-Geraete (Cognex-Scanner BX, RFID) und Antriebsparameter sind **nicht** enthalten — diese werden anderweitig projektiert. + +Umfang: ILS-1 (UH01) 443 Tags, ILS-2 (UH02) 1578 Tags, ILS-3 (UH03) 1608 Tags, ILS-4 (UH04) 203 Tags, ILS-5 (UH05) 243 Tags. + +## Namenspraefixe (BMK-Schema) + +| Praefix | Bedeutung | Beispiel | +| --- | --- | --- | +| `BG` | Sensor / Geber (Eingang) | `BG0280`: in Separator LS1 | +| `SF` | Schalter / Taster / Sicherheitssignal (Eingang) | `SF0025`: Schluesselschalter LS1 | +| `DI` | Diagnose-/Feedback-Eingang (Sicherung, Schuetz) | `DI0011`: Feedback Hauptschuetze aktiv | +| `BP` | Druckschalter | `BP0004`: Druckschalter Druckluft OK | +| `MB` | Ausgang Separator-/Stopper-Ventil | `MB0280`: Separator LS1 | +| `MA` | Ausgang Motor (Contactor) | `MA0060`: Motor (ILS-KR-M0101) | +| `QA` | Ausgang Motor / Hauptschuetz | `QA0071`: Motor 1 Ausfahren LS1 | +| `DQ` | Digitalausgang Sonderfunktion (Fuss, RFID-Handshake) | `DQ0322`: Stuetzfuss aufwaerts LS1 | +| `FC` | Motorschutz-Feedback | `FC0060`: MSS ausgeloest (ILS-KR-M0101) | +| `PF` | Leuchtmelder / Signalsaeule | `PF0022`: Signalsaeule gruen "Betriebsbereit" | + +## Was daraus automatisch fuers JSON gewinnbar ist + +### Vollstaendig generierbar + +| JSON-Abschnitt / Zielbaustein | Quelle | +| --- | --- | +| `sensors[]` -> `FB_CallSensors`, Dimensionierung `DB_Inputs` | TIA "PLC Tags" (alle BG-Tags: id, hwInput, Kommentar) + "Constants" (`cInBG...` ist exakt der Sensor-Array-Index) | +| Konstanten-Tabelle (TIA-Konstantenliste) | Constants-Blatt 1:1 | +| PLC-Variablentabellen (Ordner `PLC-Variablen/Mewa`) | "PLC Tags" — das ist der eigentliche Importzweck der Datei | +| `outputs`-Felder der TROs/Conveyors/LoadingBooms | MB (Stopper/Separatorventile), MA/QA/DQ (Motoren), FC (Motorschutz), PF (Leuchtmelder) | + +### Teilweise generierbar — ueber Kommentar-Parsing + +Die Kommentare folgen einem erstaunlich systematischen Muster: + +```text + [] () +``` + +Beispiele: `in Separator 1 (ILS-CV M5003) WS1.1`, `AE Abzweig Str.3 (Block 1.1.1)`, `Pin Abfrage (KR-M1101) Block 1.1.1`. + +Daraus laesst sich je Foerdertechnik-Einheit (M-Nummer) ein **TRO-/Conveyor-Geruest** ableiten: + +- `sensorInSep` aus "in Separator n", Stopper-Output aus "Separator n", `sensorJam*` aus "Stausensor"/"Staumelder Einfahrt" +- Der **FB-Typ** ist heuristisch bestimmbar: + - "AE Abzweig" -> Weiche (`1SepNSwi`) + - "Mitnehmerfinger in Position" / "Foerderer voll" / "MT in Position" -> `Vario` + - "Pin Abfrage" / "Pruefung MT Pos.x" -> `PinStore` + - mehrere "Str.1"..."Str.8" unter einem Block -> mehrzeiliger Puffer/Block + - Anzahl der "in Separator n" (1 vs. 2) -> 1Sep vs. 2Sep +- `conveyors[]`-Grundgeruest: FC/MA-Paare je `KR-M...`/`CV-M...` -> `motorProtectName` + `powerContactor` + +Die M-Nummern tauchen unveraendert auch im SCL-Code auf (Beleg: `REGION Carousel KR-M5002` in UH05/FB_Main.scl, `TRO208 : "FB_ILS_MTRO_PinStore_Auto"; // Block 1.1.1` in UH02/FB_Main.scl) — die Zuordnung Liste <-> Code ist also nicht nur Vermutung, sondern nachweisbar identisch. + +### Nicht gewinnbar + +- Timing-Parameter (`trailingTime`, `handlingTime`, `senFree`/`senWait` etc.) +- Priority-Manager-Verdrahtung, Release-Ausdruecke +- `customCode`-Bloecke +- Scanner-Zuordnung (Cognex BX-Geraete sind PROFINET-Teilnehmer, nicht in den Digital-E/A-Listen) +- Vor allem die **Topologie**: `connections[]`, `jamAreas[]`, `routing`/`destinations[]`. Die Reihenfolge der M-Nummern liefert nur einen schwachen Hinweis auf Nachbarschaft, keine belastbare Verkettung. + +## Hoehere Ebenen in den Listen + +Die Listen enthalten eine durchgaengige **Anlagenhierarchie**, die im aktuellen JSON-Konzept noch nicht abgebildet ist: + +1. **Signal** — BG/MB/MA/FC/PF/SF/QA/DQ (unterste Ebene) +2. **Foerdertechnik-Einheit = M-Nummer** — `KR-M5002` (Kreisel), `CV-M5003` (Foerderer), `KR-K1101` (Kreisel-Einfahrt). Entspricht 1:1 einem Conveyor bzw. einer TRO-Instanz. +3. **Bereichs-/Funktionsgruppen = Gruppen von TROs**: + - **Block x.y.z** — PinStore-Bloecke, z.B. UH02: Block 1.1.1 – 1.3.4 (3 Gassen x 4 Ebenen = 12 Bloecke), deckungsgleich mit den Datenbausteinen `DB_Storage1.1.1` ... `DB_Storage1.3.4`; darunter je Block bis zu 8 Gassen ("Str.1"..."Str.8") + - **LS 1 / LS 2** — Ladeschleifen in UH01 (Boom-, Fuss-, Rad-Signale) + - **WS x.y** — Work Stations in UH04/UH05 (manuelle Arbeitsplaetze) + - **UZ0x0y** — Umzaeunungs-/Sicherheitszonen (Reset-/Freigabe-Taster je Zone) -> entspricht den `controlUnits` im JSON-Konzept +4. **Elektro-Topologie** (nur in den WSCAD-Listen, ueber das Feld "Bezug") — UC-Feldstationen mit Klemmenkarten (`KF1DI1`, `KF1FDQ2` = fehlersichere Karte, 8 oder 16 Kanaele). Die UC-Nummerierung spiegelt die logischen Bereiche: UH02 nutzt z.B. `UC21xx`/`UC22xx`/`UC23xx` fuer die drei PinStore-Bloecke 2.1/2.2/2.3; F-Karten markieren zugleich die Safety-relevanten Signale. +5. **Steuerung UH0x** — je Dateitripel eine SPS-Konfiguration, entspricht dem `plc`-Abschnitt im JSON. + +## Verwendung von Positionen + +Zusaetzlich zu den Excel-Listen liegen in `data/Eingaben/` vier JSON-Dateien mit Positions- und Verkabelungsdaten, offenbar Exporte eines WSCAD/CAD-Auswertungstools: + +| Datei | Inhalt | +| --- | --- | +| `ST500592_10_5-9_ILS_positions.json` | Positionen (x/y in mm) aller Sensoren/Aktoren, Schaltschrankelemente und Verteiler des ILS-Systems (UH01–UH05) | +| `ST500592_10_5-9_ILS_todraw.json` | Kabelverbindungen (Verteiler ↔ Signal) mit Routing-Polylinie und -laenge, Kabeltrassen (`rack_geometry`), Fehlerprotokolle | +| `ST500592_Omniflo_positionsdraw.json` / `ST500592_10_5-10_Omniflo_todraw.json` | Gleiches Schema, aber fuer ein weiteres System ("Omniflo", `SPS` 6/7 = UH06/UH07) — **keine** SCL-Konfiguration dazu im Repository, also vermutlich eine benachbarte/zukuenftige Anlage ausserhalb des aktuellen Scopes | + +### Struktur + +- **`sensors`** / **`schaltschrank_elemente`**: Dict, Schluessel `@` (z.B. `BG3260@4`), da BMK-Namen ueber die SPSen hinweg wiederverwendet werden. Werte enthalten u.a. `pos` (x,y in mm), `BEZEICHNUNG` (Kommentartext, identisch zur TIA/EA-Liste), `KENNZEICHNUNG` (WSCAD-Ortskennzeichen), `SPS` und **`VERW`**. +- **`VERW`** ist ein kontrolliertes Vokabular fuer die Funktionsrolle des Signals, z.B. `Sep`, `In sep`, `Jam detector`, `ES branch` (Weichen-Abzweig!), `conveyor full`, `MT in Position`, `Finger in position`, `PIN query`, `Sync P1`–`P4`. Das ist eine **zuverlaessigere Quelle fuer die Rollenklassifikation** als das Parsen der freien Kommentartexte (siehe oben) — z.B. laesst sich eine Weiche (`ES branch`) oder ein Vario-Sync-Punkt (`Sync Px`) direkt am `VERW`-Wert erkennen statt ueber Text-Heuristik. +- **`mappings`**: Verteiler (`UC0401`, ...) -> Liste der daran angeschlossenen BMK — das ist die **belastbare** (aus der Verkabelung stammende) Zuordnung Signal -> Schaltschrank, nicht nur eine Namenskonvention wie in der WSCAD-Excelliste. +- **`distributors`**: Verteiler -> eigene Position (x,y). +- **`kabel`** (nur `_todraw.json`): je Verbindung `id` (`"-@"`), Routing-Polylinie (`coords`) und `length` (mm) — die tatsaechliche Kabelstrecke inkl. Verlegung ueber Kabeltrassen/Pritschen. +- **`rack_geometry`** / **`tunnels`**: Geometrie der Kabeltrassen bzw. Bodentunnel, auf denen die Kabel gefuehrt werden. +- **`not_found`** / `errors_*` / `warnings`: Validierungsprotokoll des Exporttools (fehlende Verteilerzuordnung, ungueltige Kennzeichnung, doppelte IDs, Attributsluecken) — kein Topologie-Input, aber wertvoll als **Datenqualitaets-Check** fuer einen Generator. + +### Lassen sich Topologie-Hinweise ableiten? + +Ein Abgleich der bekannten UH01-Kette (siehe [TRO_Graph_UH01-UH05.dot](TRO_Graph_UH01-UH05.dot)) gegen die Sensor-Positionen zeigt ein klares Muster: + +| TRO | Sensor | Position (x, y in mm) | Abstand zum vorherigen | +| --- | --- | --- | --- | +| TRO100 | BG3242@1 | (341906, 164862) | – | +| TRO103 | BG3271@1 | (331115, 163051) | ~10,9 m | +| TRO107 | BG3306@1 | (333164, 152428) | ~10,7 m (nach TRO105) | +| TRO104 | BG0280@1 | (370801, 187134) | ~46,4 m (Sprung!) | +| TRO105 | BG3280@1 | (334141, 159162) | ~46,1 m (Sprung zurueck!) | +| TRO109 | BG0340@1 | (376774, 187155) | liegt nahe bei TRO104 | + +Die TROs des Hauptkreislaufs (100, 103, 105, 107, ...) liegen raeumlich dicht beieinander (Abstaende im Bereich 5–15 m), waehrend TRO104/TRO109 (Vorstopper vor den Ladeschleifen LS1/LS2) einen grossen sprunghaften Abstand aufweisen — sie liegen physisch bei den Ladeschleifen, einem raeumlich getrennten Anlagenteil, zu dem die Carrier ausgeschleust und zurueckgefuehrt werden. Das deckt sich exakt mit der bereits aus dem SCL-Code extrahierten Topologie (TRO104 -> LoadingBoom1 -> TRO105). + +**Ergebnis:** Positionen liefern **keine eigenstaendige, vollstaendige Topologie** (dafuer fehlt die Information, in welcher Reihenfolge/Richtung Carrier durch nahe beieinanderliegende Elemente laufen — u.a. bei parallelen Foerderstrecken oder Bloecken mit identischen Abstaenden nicht eindeutig). Sie eignen sich aber sehr gut als: + +1. **Validierungswerkzeug** fuer die aus dem SCL-Code extrahierte `connections`-Topologie: kurze Abstaende zwischen verbundenen TROs bestaetigen Plausibilitaet, groessere Spruenge markieren bewusste Anlagenteile (Ladeschleifen, Storage-Gassen, AMR-Uebergabe) und lassen sich in der Analyse gezielt kommentieren. +2. **Raeumliche Clusterbildung**: TROs/Sensoren, die im selben Cluster von Koordinaten liegen, lassen sich automatisch zu den bereits identifizierten Bereichsgruppen (Block, LS, WS, UZ) buendeln oder solche Gruppen erst entdecken, falls die textuelle Kommentar-Zuordnung fehlt oder uneinheitlich ist. +3. **Massstabsgetreue Lageplan-Darstellung**: der bestehende TRO-Graph ([TRO_Graph_UH01-UH05.svg](TRO_Graph_UH01-UH05.svg)) nutzt eine automatische Graphviz-Anordnung ohne Bezug zur echten Anlage. Mit den `pos`-Koordinaten liesse sich zusaetzlich ein **massstabsgetreuer Lageplan** rendern (SVG/DXF mit echten x/y-Koordinaten je TRO/Sensor), der die abstrakte Topologie mit der realen Hallenlayout ueberlagert. +4. **Cabinet-/Verteilerzuordnung**: `mappings` + `distributors` liefern die **tatsaechliche** (aus der Verkabelung stammende) Zuordnung Sensor -> Schaltschrank/Verteiler samt dessen Position — praeziser als die Namenskonvention der WSCAD-Bezugsfelder, und direkt nutzbar fuer den `controlUnits`-Abschnitt im JSON. +5. **Kabel-/Trassendokumentation**: `kabel`, `rack_geometry` und `tunnels` erlauben es, Kabellaengen und -wege je Verbindung automatisch zu dokumentieren (z.B. fuer Stuecklisten/BOM oder Trassenauslastung) — fachlich getrennt von der SPS-Programmlogik, aber ein sinnvoller Zusatznutzen derselben Datenbasis. + +## Konsequenz fuer das JSON-Layout-Konzept + +Um Ebene 2–4 aus den Excel-Listen automatisch befuellen zu koennen, sollte das JSON-Schema (siehe [Json_Layout-Konzept.md](Json_Layout-Konzept.md)) um folgende Punkte erweitert werden: + +1. Ein Feld `unit` bzw. `mNumber` an jedem TRO/Conveyor als expliziter Schluessel zur E/A-Liste (z.B. `"unit": "M5003"`). +2. Eine neue Gruppierungsebene `areas`/`groups` (Block, LS, WS, UZ, UC-Station), die TROs/Conveyors buendelt und mit dem "Bezug"-Feld der WSCAD-Liste sowie der UZ-Nummerierung der TIA-Liste verknuepft. +3. Ein optionales Feld `pos: {x, y}` je Sensor/TRO/Conveyor (aus den `..._positions.json`), fuer massstabsgetreue Layout-Darstellung und als Validierungsdatum fuer die Topologie. +4. Ein Feld `controlUnit`/`cabinet` mit dem Verteiler-BMK (aus `mappings`), zusaetzlich zur bzw. anstelle der bisherigen Ableitung aus der WSCAD-Namenskonvention. +5. Nutzung des `VERW`-Vokabulars aus den Positions-JSONs als primaere Quelle fuer die Rollenklassifikation der BG/MB-Signale (statt bzw. ergaenzend zur Kommentar-Textheuristik) — reduziert Fehlklassifikationen bei uneindeutigen Kommentaren. + +Damit waeren die Ebenen Signal, Foerdertechnik-Einheit, Bereichsgruppe, Steuerung und — als Zusatznutzen — die raeumliche Lage vollstaendig aus den Eingabelisten ableitbar. Manuell zu pflegen blieben dann nur noch die eigentliche Verkettungsrichtung der Topologie (`connections`/`destinations`), Timings und projektspezifische Sonderlogik (`customCode`). diff --git a/doc/Json_Layout-Konzept.md b/doc/Json_Layout-Konzept.md index ff65109..53beb0f 100644 --- a/doc/Json_Layout-Konzept.md +++ b/doc/Json_Layout-Konzept.md @@ -941,6 +941,253 @@ Ermoeglicht automatische Generierung von `FC_Direction` ohne manuelles Pflegen v --- +### 13. Topologie-Graph UH01 — TRO-Ein- und Ausgänge + +Jede Verbindung wird über eine JamArea realisiert. Abkürzung `JAxxxx_y` steht für `"DB_JamAreaxxxx".stJamxxxx_y`. +Switch-TROs (Typ `1Sep1Swi`) besitzen zwei Ausgänge (Dir1 / Dir2); ihre Richtungsentscheidung kommt aus `FC_Direction`. + +#### Inbound-Hauptschleife (Mermaid-Diagramm) + +```mermaid +flowchart LR + classDef sep fill:#d4e8ff,stroke:#3388cc + classDef swi fill:#ffe4a0,stroke:#cc8800 + classDef buf fill:#d4f0d4,stroke:#338833 + classDef vario fill:#e8d4f0,stroke:#883388 + classDef sscc fill:#ffd4d4,stroke:#cc3333 + classDef ext fill:#f0f0f0,stroke:#888,stroke-dasharray:5 + + EXT_IN([Externer Eingang]):::ext + EXT_OUT([InboundOut to WCS]):::ext + + EXT_IN -->|JA0100_1| TRO100:::sep + TRO100 -->|JA0101_1| TRO101_IN:::sep + TRO101_IN -->|JamBuf101| TRO101[TRO101 EmptyBuf]:::buf + TRO101_IN -->|JA0101_2| TRO102_IN:::sep + TRO102_IN -->|JamBuf102| TRO102[TRO102 EmptyBuf]:::buf + TRO101 -->|JA0102_2| TRO112:::swi + TRO102 -->|JA0102_1| TRO107:::swi + + TRO107 -->|Dir1 JA0103_1| TRO103:::sep + TRO107 -->|Dir2 JA0102_2| TRO112 + TRO103 -->|JA0104_1| TRO104:::sep + TRO104 -->|JA0104_2| LB1([LoadingBoom 1]):::ext + LB1 -->|JA0104_3| TRO105:::sscc + TRO105 -->|JA0106_2| TRO106:::sep + TRO106 -->|JA0102_2| TRO112 + + TRO112 -->|Dir1 JA0107_1| TRO108:::sep + TRO112 -->|Dir2 JA0102_3| TRO113:::sep + TRO108 -->|JA0108_1| TRO109:::sep + TRO109 -->|JA0108_2| LB2([LoadingBoom 2]):::ext + LB2 -->|JA0108_3| TRO110:::sscc + TRO110 -->|JA0110_2| TRO111:::sep + TRO111 -->|JA0102_3| TRO113 + + TRO113 -->|JA0102_4| TRO114:::swi + TRO114 -->|Dir1 JA4104_1| TRO115:::vario + TRO115 --> EXT_OUT + TRO114 -->|Dir2 JA0102_5| TRO116:::sep + TRO116 -->|JA0102_6| TRO117:::sep + TRO117 -.->|JA0102_1 Clearing-Rückf.| TRO107 +``` + +#### Highway / Storage-Verbindungen (Mermaid-Diagramm) + +```mermaid +flowchart LR + classDef sep fill:#d4e8ff,stroke:#3388cc + classDef swi fill:#ffe4a0,stroke:#cc8800 + classDef vario fill:#e8d4f0,stroke:#883388 + classDef ext fill:#f0f0f0,stroke:#888,stroke-dasharray:5 + + HWY_IN([Highway Loaded In]):::ext -->|JA4103_1| TRO120:::vario + ST_IN1([Storage Empty In]):::ext -->|JA4503_1| TRO121:::vario + ST_IN1 -->|JA4503_2| TRO122:::sep + TRO122 -->|JA4502_1| TRO123:::vario + BORNER1([Borner Eingang 1]):::ext -->|JA4502_2| TRO124:::swi + TRO124 -->|Dir1 JA4204_2| TRO125:::sep + TRO125 -->|JA4203_1| TRO126:::vario + TRO126 --> STORAGE([Storage]):::ext + TRO124 -->|Dir2 JA4501_1| TRO127:::vario + EMPTY_IN([Leere Carrier von Highway]):::ext -->|JA4501_2| TRO128:::vario + BORNER2([Borner Eingang 2]):::ext -->|JA4302_2| TRO129:::sep + TRO129 -->|JA4204_1| TRO130:::sep + TRO130 -->|JA4501_1| TRO127 + AMR_IN([Loaded to AMR]):::ext -->|JA4403_1| TRO131:::vario + TRO131 --> AMR([AMR-System]):::ext + HWY_IN2([Highway Eingang 2]):::ext -->|JA4302_1| TRO133:::vario + AMR_HWY([AMR Highway]):::ext -->|JA4402_1| TRO134:::vario +``` + +#### TRO-Tabelle: Zone A — Eingang / Leere-Carrier-Puffer + +| TRO | Typ | Beschreibung | Eingang JamArea | Eingang von | Ausgang JamArea | Ausgang zu | +|---|---|---|---|---|---|---| +| TRO100 | 1Sep | Anlageneingang | JA0100.stJam0100_1 | Externer Eingang | JA0101.stJam0101_1 | TRO101_IN | +| TRO101_IN | 1Sep | Separator Empty Buffer rechts | JA0101.stJam0101_1 | TRO100 | DB_JamBuffer101 / JA0101.stJam0101_2 | TRO101 / TRO102_IN | +| TRO101 | EmptyCarrBuffer | Leere-Carrier-Puffer rechts | DB_JamBuffer101 | TRO101_IN | JA0102.stJam0102_2 | TRO112 | +| TRO102_IN | 1Sep | Separator Empty Buffer links | JA0101.stJam0101_2 | TRO101_IN | DB_JamBuffer102 | TRO102 | +| TRO102 | EmptyCarrBuffer | Leere-Carrier-Puffer links | DB_JamBuffer102 | TRO102_IN | JA0102.stJam0102_1 | TRO107 | + +#### TRO-Tabelle: Zone B — Loading Station 1 + +| TRO | Typ | Beschreibung | Eingang JamArea | Eingang von | Ausgang JamArea | Ausgang zu | +|---|---|---|---|---|---|---| +| TRO103 | 1Sep | Zufahrt Loading Station 1 | JA0103.stJam0103_1 | TRO107 (Dir1) | JA0104.stJam0104_1 | TRO104 | +| TRO104 | 1Sep | Vorstopper LS1 + Barcode-Scanner | JA0104.stJam0104_1 | TRO103 | JA0104.stJam0104_2 | LoadingBoom1 (Stopper) | +| TRO105 | 1Sep_SSCC | SSCC-Scanner nach LS1 | JA0104.stJam0104_3 | LoadingBoom1 (nach Beladung) | JA0106.stJam0106_2 | TRO106 | +| TRO106 | 1Sep | Abfuhr Loading Station 1 | JA0106.stJam0106_2 | TRO105 | JA0102.stJam0102_2 | TRO112 | + +#### TRO-Tabelle: Zone C — Loading Station 2 + +| TRO | Typ | Beschreibung | Eingang JamArea | Eingang von | Ausgang JamArea | Ausgang zu | +|---|---|---|---|---|---|---| +| TRO108 | 1Sep | Zufahrt Loading Station 2 | JA0107.stJam0107_1 | TRO112 (Dir1) | JA0108.stJam0108_1 | TRO109 | +| TRO109 | 1Sep | Vorstopper LS2 + Barcode-Scanner | JA0108.stJam0108_1 | TRO108 | JA0108.stJam0108_2 | LoadingBoom2 (Stopper) | +| TRO110 | 1Sep_SSCC | SSCC-Scanner nach LS2 | JA0108.stJam0108_3 | LoadingBoom2 (nach Beladung) | JA0110.stJam0110_2 | TRO111 | +| TRO111 | 1Sep | Abfuhr Loading Station 2 | JA0110.stJam0110_2 | TRO110 | JA0102.stJam0102_3 | TRO113 | + +#### TRO-Tabelle: Zone D — Switches / Hauptrouting + +| TRO | Typ | Beschreibung | Eingang JamArea | Eingang von | Ausgang Dir1 | Ausgang Dir2 | +|---|---|---|---|---|---|---| +| TRO107 | 1Sep1Swi | Switch: LS1 / LS2+Clearing | JA0102.stJam0102_1 | TRO102, TRO117 (Rückf.) | JA0103.stJam0103_1 → TRO103 | JA0102.stJam0102_2 → TRO112 | +| TRO112 | 1Sep1Swi | Switch: LS2 / Clearing+Ausgang | JA0102.stJam0102_2 | TRO101, TRO106, TRO107(D2) | JA0107.stJam0107_1 → TRO108 | JA0102.stJam0102_3 → TRO113 | +| TRO113 | 1Sep | Zufahrt Clearing + Barcode-Scanner | JA0102.stJam0102_3 | TRO111, TRO112 (Dir2) | JA0102.stJam0102_4 → TRO114 | — | +| TRO114 | 1Sep1Swi | Switch: InboundOut / Clearing + Scanner | JA0102.stJam0102_4 | TRO113 | JA4104.stJam4104_1 → TRO115 | JA0102.stJam0102_5 → TRO116 | + +#### TRO-Tabelle: Zone E — Clearing-Station + +| TRO | Typ | Beschreibung | Eingang JamArea | Eingang von | Ausgang JamArea | Ausgang zu | +|---|---|---|---|---|---|---| +| TRO116 | 1Sep | Zufahrt Clearing-Station | JA0102.stJam0102_5 | TRO114 (Dir2) | JA0102.stJam0102_6 | TRO117 | +| TRO117 | 1Sep | Clearing-Station (HMI + customCode) | JA0102.stJam0102_6 | TRO116 | JA0102.stJam0102_1 | TRO107 (Clearing-Rückführung) | + +#### TRO-Tabelle: Zone F — InboundOut + +| TRO | Typ | Beschreibung | Eingang JamArea | Eingang von | Ausgang | Ausgang zu | +|---|---|---|---|---|---|---| +| TRO115 | Vario | Übergabe InboundOut | JA4104.stJam4104_1 | TRO114 (Dir1) | WCS-Telegramm | Externes System (WCS/UH04) | + +#### TRO-Tabelle: Zone G — Highway / Storage (Cross-UH-Verbindungen) + +| TRO | Typ | Beschreibung | Eingang JamArea | Eingang von | Ausgang JamArea | Ausgang zu | +|---|---|---|---|---|---|---| +| TRO120 | Vario | Loaded Carrier von Highway eingehend | JA4103.stJam4103_1 | Highway-Extern | — | Borner-Einspeisung | +| TRO121 | Vario | Eingang Speicher-Kreislauf 1 | JA4503.stJam4503_1 | Extern | — | — | +| TRO122 | 1Sep | Speicher-Transition | JA4503.stJam4503_2 | Extern | JA4502.stJam4502_1 | TRO123 | +| TRO123 | Vario | Speicher-Übergabe | JA4502.stJam4502_1 | TRO122 | — | — | +| TRO124 | 1Sep1Swi | Switch: Carousel / Highway-Storage | JA4502.stJam4502_2 | Extern | Dir1: JA4204.stJam4204_2 → TRO125 | Dir2: JA4501.stJam4501_1 → TRO127 | +| TRO125 | 1Sep | Highway-Exit Richtung Carousel | JA4204.stJam4204_2 | TRO124 (Dir1) | JA4203.stJam4203_1 | TRO126 | +| TRO126 | Vario | Leere Carrier → Storage | JA4203.stJam4203_1 | TRO125 | — | Storage | +| TRO127 | Vario | Highway-Ausgang | JA4501.stJam4501_1 | TRO124(D2), TRO130 | — | — | +| TRO128 | Vario | Leere Carrier → Inbound (von Highway) | JA4501.stJam4501_2 | Extern | — | — | +| TRO129 | 1Sep | Borner-Eingang Seite 2 | JA4302.stJam4302_2 | Extern | JA4204.stJam4204_1 | TRO130 | +| TRO130 | 1Sep | Transition zu Highway | JA4204.stJam4204_1 | TRO129 | JA4501.stJam4501_1 | TRO127 | +| TRO131 | Vario | Loaded Carrier → AMR | JA4403.stJam4403_1 | Extern | — | AMR-System | +| TRO132 | 1Sep | (auskommentiert — nicht aktiv) | — | — | — | — | +| TRO133 | Vario | Highway-Eingang 2 | JA4302.stJam4302_1 | Extern | — | — | +| TRO134 | Vario | AMR Highway | JA4402.stJam4402_1 | Extern | — | — | + +--- + +### 14. Erweiterungen aus der E/A-Listen- und Positionsdaten-Analyse + +Die Analyse der Eingabelisten in `data/Eingaben/` (siehe [EA-Listen-Analyse.md](EA-Listen-Analyse.md)) hat gezeigt, dass grosse Teile des JSON automatisch aus den Projektierungsdaten befuellbar sind. Dafuer werden folgende Schema-Erweiterungen eingefuehrt: + +#### 14.1 Feld `unit` je TRO/Conveyor (Schluessel zur E/A-Liste) + +Jede TRO-/Conveyor-Instanz erhaelt die Foerdertechnik-Einheit (M-Nummer) als expliziten Schluessel. Die M-Nummern stehen in den Kommentaren der E/A-Listen und identisch in den REGION-Namen des SCL-Codes: + +```json +{ + "id": "TRO115", + "unit": "M4104", + "unitKind": "CV", + "type": "Vario", + "pos": { "x": 341906, "y": 164862 }, + "cabinet": "UC1101" +} +``` + +| Feld | Quelle | Bedeutung | +|---|---|---| +| `unit` | Kommentar E/A-Liste (`(ILS-CV M4104)`) | M-Nummer der mechanischen Einheit | +| `unitKind` | dito | `KR` = Kreisel/Carousel, `CV` = Conveyor, `K` = Kreisel-Einfahrt | +| `pos` | `..._positions.json` -> `sensors[@].pos` | x/y-Lage in mm (Referenzsensor der Einheit) | +| `cabinet` | `..._positions.json` -> `mappings` | Verteiler/Schaltschrank aus der realen Verkabelung | + +#### 14.2 Gruppierungsebene `areas` + +Neue Top-Level-Ebene, die TROs/Conveyors zu den in den Listen gefundenen Bereichsgruppen buendelt: + +```json +"areas": [ + { + "id": "Block 1.1.1", + "kind": "pinStoreBlock", + "members": ["TRO208", "TRO209", "TRO210"], + "ucStations": ["UC2101"], + "safetyZone": "UZ0201", + "storageDb": "DB_Storage1.1.1", + "lines": 8 + }, + { + "id": "LS1", + "kind": "loadingStation", + "members": ["TRO103", "TRO104", "TRO105", "TRO106", "LoadingBoom1"], + "safetyZone": "UZ0110" + }, + { + "id": "WS1.1", + "kind": "workStation", + "members": ["TRO421"] + } +] +``` + +Gefundene `kind`-Werte: `pinStoreBlock` (Block x.y.z, UH02/UH03), `loadingStation` (LS 1/2, UH01), `workStation` (WS x.y, UH04/UH05), `safetyZone` (UZ0x0y), `ucStation` (Feldstation/Verteiler). + +#### 14.3 Rollenklassifikation ueber das `VERW`-Vokabular + +Die Positions-JSONs (`..._positions.json`) enthalten je Signal das Feld `VERW` — ein kontrolliertes Vokabular, das zuverlaessiger ist als das Parsen der freien Kommentartexte: + +| `VERW`-Wert | Rolle im JSON | Hinweis auf FB-Typ | +|---|---|---| +| `In sep` | `separator.sensorInSep` | — | +| `Sep` | `outputs.stopper*` (MB-Ausgang) | — | +| `Jam detector` / `Jam detector (LP)` | `sensorJam*` | — | +| `ES branch` | `outputs.sw*ExTo*` (Weichenausgang) | `1SepNSwi` | +| `conveyor full` | `vario.sensors.jam` / Puffer voll | `Vario` | +| `MT in Position` | `vario.sensors.carrInPos` | `Vario` | +| `Finger in position` | `vario.sensors.finger` | `Vario` | +| `PIN query` | PinStore-Abfrage | `PinStore_Auto` | +| `Sync P1`..`P4` | Synchronisationspunkte | PinStore/Vario-Sonderform | +| `Rad dreht` | LoadingBoom Rad-Sensor | LoadingBoom | + +Heuristik fuer den FB-Typ je Einheit: `ES branch` vorhanden -> Weiche; `Finger`/`MT in Position`/`conveyor full` -> `Vario`; `PIN query` -> `PinStore_Auto`; Anzahl `In sep` (1/2) -> `1Sep`/`2Sep`; nur FC/MA-Paar ohne Separator -> `FB_Conveyor`. + +#### 14.4 Quellen-Uebersicht + +| Datenquelle | Liefert | +|---|---| +| `..._TIA.xlsx` "PLC Tags" | BMK-Name, Datentyp, `%E/%A`-Adresse, Kommentar -> `sensors[]`, `outputs` | +| `..._TIA.xlsx` "Constants" | `cIn...`-Indexkonstanten -> Konstanten-Tabelle, `sensors[].constant` | +| `..._WSCAD.xlsx` "Bezug" | Ortskennzeichen `=A01+UCxxxx-KF1DIx` -> Karten-/Stationszuordnung | +| `..._positions.json` | `pos` (x/y), `VERW` (Rolle), `mappings` (Signal->Verteiler), `distributors` (Verteiler-Position) | +| `..._todraw.json` | Kabelwege und -laengen (Doku/BOM, nicht SPS-relevant) | + +Nicht aus den Listen ableitbar bleiben: Timings, Priority-Manager, Release-Ausdruecke, Scanner-Zuordnung (BX = PROFINET), `customCode` und die Verkettungsrichtung der Topologie (`connections`/`destinations`). Die Positionen dienen dabei als Plausibilitaets-Check der Topologie (kurze Abstaende = wahrscheinliche Nachbarn) und fuer massstabsgetreue Lageplaene. + +#### 14.5 Skeleton-Generator + +Das Skript [lib/create_skel.py](../lib/create_skel.py) (Aufruf ueber `bin\create_skel.bat`) liest die Eingabelisten und erzeugt je Steuerung ein Skeleton der JSON-Zwischendatei (`results/skeleton_UH0x.json`) sowie ein SCL-Grundgeruest. Die globalen Definitionen werden beim Programmstart aus `PV_CFG` geladen: [cfg/skel.cfg](../cfg/skel.cfg) (JSON: Dateinamen, `VERW`-Vokabular, FB-Typ-Regeln) und [cfg/skel_scl.cfg](../cfg/skel_scl.cfg) (INI-Style: die SCL-Aufruf-Templates, zeilenweise lesbar — jede `[sektion]` ist ein Template, der Inhalt wird verbatim inkl. Einrueckung und Leerzeilen uebernommen). Fehlende Konfigurationsdateien fallen auf die im Skript eingebauten Defaults zurueck (Cold-Start-faehig). + +Mit `--con-ini` bzw. `--con-json` liest der Generator zusaetzlich die TRO-Topologie aus [data/connect.ini](../data/connect.ini) bzw. [data/connect.json](../data/connect.json) (Format `hmf-connect-v1`, extrahiert aus [TRO_Graph_UH01-UH05.dot](TRO_Graph_UH01-UH05.dot)) und ergaenzt jedes Skeleton um einen `topology`-Abschnitt: je TRO die aufgeloeste JamArea-Verdrahtung (`entries`/`exits` inkl. `dbRef` auf `"DB_JamAreaxxxx".stJamxxxx_y`), dazu die rohen `connections`/`externals`-Listen. Beide Eingabewege liefern identische Ergebnisse. + +--- + ## Welche SCL-Bausteine werden daraus generiert? | Ziel-Baustein | Generiert aus JSON-Abschnitt | diff --git a/doc/TRO_Graph_UH01-UH05.dot b/doc/TRO_Graph_UH01-UH05.dot new file mode 100644 index 0000000..dea7585 --- /dev/null +++ b/doc/TRO_Graph_UH01-UH05.dot @@ -0,0 +1,705 @@ +// ============================================================================ +// TRO-Topologie-Graph der Gesamtanlage HundM_Fortna (UH01 - UH05) +// ============================================================================ +// +// Format: Graphviz DOT (https://graphviz.org) +// Rendern z.B. mit: dot -Tsvg TRO_Graph_UH01-UH05.dot -o graph.svg +// oder online: https://dreampuf.github.io/GraphvizOnline +// +// Quelle: Automatisch extrahiert aus den FB_Main.scl der 5 Steuerungen +// (=A01+UH01-KF00 ... =A01+UH05-KF00, Ordner 100_Main). +// Erzeugt von bin/generate_tro_graph.py. +// +// Methode: Jeder TRO-Baustein (FB_ILS_MTRO_*, FB_EmptyCarrBuffer, +// FB_LoadingBoom_INBOUND) referenziert JamAreas als Parameter: +// arInOutJamEntr* / arInOutStorageLines / arInOutCarrierStopper = Eingang +// arInOutJamExit* / arInOutJamBypass / arInOutJamFinger / +// arInOutCarrierExit = Ausgang +// Zwei TROs sind verbunden, wenn der Ausgangs-Slot des einen +// dieselbe JamArea referenziert wie der Eingangs-Slot des anderen. +// Auskommentierter Code wurde ignoriert. +// +// Knoten: Ein Knoten je TRO-Instanz, Label: Name, [FB-Typ], REGION-Kommentar +// aus FB_Main. Farbe/Form nach FB-Typ: +// hellblau/Box = 1Sep (Standard-Separator) +// rot/Box = 1Sep_SSCC (SSCC-Scanner + WCS-Telegramm) +// gelb/Raute = 1Sep1Swi, 1Sep2Swi, 2Sep1Swi (Weichen) +// violett/Parallelogr.= Vario (Kettenfoerderer) +// tuerkis/Parallelogr.= Vario_workStation (manueller Arbeitsplatz) +// gruen/3D-Box = EmptyCarrBuffer (Leertablar-Puffer) +// grau = Sonstige (z.B. LoadingBoom, PinStore) +// +// Kanten: Label = JamArea-Slot (JAxxxx_y = "DB_JamAreaxxxx".stJamxxxx_y). +// Zusatz "Dir2"/"Dir3" = Weichen-Ausgang (arInOutJamExit3/4), +// Richtungsentscheidung kommt aus FC_Direction. +// Gestrichelt "Bypass" = Bypass-Spur (PinStore), +// gestrichelt "Finger" = Finger-Uebergabe eines Vario-Foerderers. +// +// EXTERN: Graue Kanten zu EXTERN-Knoten = JamAreas, die nur auf einer +// Seite belegt sind (Anlagengrenze, Uebergabe an WES/WCS, AMR +// oder andere SPS). CPU-CPU-Uebergaben zwischen den Steuerungen +// sind an den Labels "IO_Device_UHxx_TO_UHyy..." erkennbar +// (PROFINET-Direktkopplung, kein gemeinsamer JamArea-DB). +// +// Hinweis: Kanten existieren nur innerhalb einer Steuerung, da JamArea-DBs +// nicht SPS-uebergreifend geteilt werden. Der physische Fluss +// zwischen den UHs laeuft ueber die EXTERN-Uebergaben. +// +// Umfang: 250 TRO-Knoten, 284 Verbindungen (Stand der Extraktion siehe Git-Historie) +// UH01: 36 TROs, 37 Verbindungen +// UH02: 74 TROs, 88 Verbindungen +// UH03: 84 TROs, 102 Verbindungen +// UH04: 24 TROs, 25 Verbindungen +// UH05: 32 TROs, 32 Verbindungen + +digraph TRO_Topologie { + rankdir = "LR"; + fontname = "Arial"; + node [fontname="Arial", fontsize=10]; + edge [fontname="Arial", fontsize=8]; + label = "TRO-Topologie HundM_Fortna (UH01-UH05)"; + labelloc = "t"; + + subgraph "cluster_UH01" { + label = "UH01 (=A01+UH01-KF00)"; + style = "rounded"; + color = "#888888"; + "UH01.TRO100" [label="TRO100\n[1Sep]\nTRO 100 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO101" [label="TRO101\n[EmptyCarrBuffer]\nTRO101 (Empty Buffer rechts)", shape=box3d, style=filled, fillcolor="#d4f0d4"]; + "UH01.TRO101_IN" [label="TRO101_IN\n[1Sep]\nTRO 101_IN(1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO102" [label="TRO102\n[EmptyCarrBuffer]\nTRO102 (Empty Buffer links)", shape=box3d, style=filled, fillcolor="#d4f0d4"]; + "UH01.TRO102_IN" [label="TRO102_IN\n[1Sep]\nTRO 102_IN(1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO103" [label="TRO103\n[1Sep]\nTRO 103 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO104" [label="TRO104\n[1Sep]\nTRO 104 (1Sep)+Scanner", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO105" [label="TRO105\n[1Sep_SSCC]\nTRO 105 (1Sep)+Scanner", shape=box, style=filled, fillcolor="#ffd4d4"]; + "UH01.TRO106" [label="TRO106\n[1Sep]\nTRO 106 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO107" [label="TRO107\n[1Sep1Swi]\nTRO 107(1Sep1Swi)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH01.TRO108" [label="TRO108\n[1Sep]\nTRO 108 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO109" [label="TRO109\n[1Sep]\nTRO 109 (1Sep)+Scanner", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO110" [label="TRO110\n[1Sep_SSCC]\nTRO 110 (1Sep)+Scanner", shape=box, style=filled, fillcolor="#ffd4d4"]; + "UH01.TRO111" [label="TRO111\n[1Sep]\nTRO 111 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO112" [label="TRO112\n[1Sep1Swi]\nTRO 112 (1Sep1Swi)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH01.TRO113" [label="TRO113\n[1Sep]\nTRO 113 (1Sep)+Scanner", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO114" [label="TRO114\n[1Sep1Swi]\nTRO 114 (1Sep1Switch)+Scanner", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH01.TRO115" [label="TRO115\n[Vario]\nTRO 115 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH01.TRO116" [label="TRO116\n[1Sep]\nTRO 116 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO117" [label="TRO117\n[1Sep]\nTRO 117 (1Sep) + Scanner", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO120" [label="TRO120\n[Vario]\nTRO 120 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH01.TRO121" [label="TRO121\n[Vario]\nTRO 121(Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH01.TRO122" [label="TRO122\n[1Sep]\nTRO 122 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO123" [label="TRO123\n[Vario]\nTRO 123 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH01.TRO124" [label="TRO124\n[1Sep1Swi]\nTRO 124 (1Sep1Switch)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH01.TRO125" [label="TRO125\n[1Sep]\nTRO 125 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO126" [label="TRO126\n[Vario]\nTRO 126 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH01.TRO127" [label="TRO127\n[Vario]\nTRO 127 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH01.TRO128" [label="TRO128\n[Vario]\nTRO 128 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH01.TRO129" [label="TRO129\n[1Sep]\nTRO 129 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO130" [label="TRO130\n[1Sep]\nTRO 130 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH01.TRO131" [label="TRO131\n[Vario]\nTRO 131 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH01.TRO133" [label="TRO133\n[Vario]\nTRO 133 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH01.TRO134" [label="TRO134\n[Vario]\nTRO 134 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH01.fbLoadingBoom1" [label="fbLoadingBoom1\n[LoadingBoom_INBOUND]\nLoadingBoom 1", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH01.fbLoadingBoom2" [label="fbLoadingBoom2\n[LoadingBoom_INBOUND]\nLoadingBoom 2", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH01.EXTERN_IN" [label="EXTERN\n(Zulauf)", shape=ellipse, style="filled,dashed", fillcolor="#f8f8f8"]; + "UH01.TRO128" -> "UH01.TRO100" [label="JA0100_1 Finger", style=dashed]; + "UH01.TRO100" -> "UH01.TRO101_IN" [label="JA0101_1"]; + "UH01.TRO101_IN" -> "UH01.TRO102_IN" [label="JA0101_2"]; + "UH01.TRO102" -> "UH01.TRO107" [label="JA0102_1"]; + "UH01.TRO117" -> "UH01.TRO107" [label="JA0102_1"]; + "UH01.TRO101" -> "UH01.TRO112" [label="JA0102_2"]; + "UH01.TRO106" -> "UH01.TRO112" [label="JA0102_2"]; + "UH01.TRO107" -> "UH01.TRO112" [label="JA0102_2 Dir2"]; + "UH01.TRO111" -> "UH01.TRO113" [label="JA0102_3"]; + "UH01.TRO112" -> "UH01.TRO113" [label="JA0102_3 Dir2"]; + "UH01.TRO113" -> "UH01.TRO114" [label="JA0102_4"]; + "UH01.TRO114" -> "UH01.TRO116" [label="JA0102_5 Dir2"]; + "UH01.TRO116" -> "UH01.TRO117" [label="JA0102_6"]; + "UH01.TRO107" -> "UH01.TRO103" [label="JA0103_1"]; + "UH01.TRO103" -> "UH01.TRO104" [label="JA0104_1"]; + "UH01.TRO104" -> "UH01.fbLoadingBoom1" [label="JA0104_2"]; + "UH01.fbLoadingBoom1" -> "UH01.TRO105" [label="JA0104_3"]; + "UH01.TRO105" -> "UH01.TRO106" [label="JA0106_2"]; + "UH01.TRO112" -> "UH01.TRO108" [label="JA0107_1"]; + "UH01.TRO108" -> "UH01.TRO109" [label="JA0108_1"]; + "UH01.TRO109" -> "UH01.fbLoadingBoom2" [label="JA0108_2"]; + "UH01.fbLoadingBoom2" -> "UH01.TRO110" [label="JA0108_3"]; + "UH01.TRO110" -> "UH01.TRO111" [label="JA0110_2"]; + "UH01.TRO115" -> "UH01.TRO120" [label="JA4103_1 Finger", style=dashed]; + "UH01.TRO125" -> "UH01.TRO126" [label="JA4203_1"]; + "UH01.TRO129" -> "UH01.TRO130" [label="JA4204_1"]; + "UH01.TRO124" -> "UH01.TRO125" [label="JA4204_2"]; + "UH01.TRO133" -> "UH01.TRO129" [label="JA4302_2 Finger", style=dashed]; + "UH01.TRO134" -> "UH01.TRO131" [label="JA4403_1 Finger", style=dashed]; + "UH01.TRO124" -> "UH01.TRO127" [label="JA4501_1 Dir2"]; + "UH01.TRO130" -> "UH01.TRO127" [label="JA4501_1"]; + "UH01.TRO127" -> "UH01.TRO128" [label="JA4501_2 Finger", style=dashed]; + "UH01.TRO122" -> "UH01.TRO123" [label="JA4502_1"]; + "UH01.TRO123" -> "UH01.TRO124" [label="JA4502_2 Finger", style=dashed]; + "UH01.TRO121" -> "UH01.TRO122" [label="JA4503_2 Finger", style=dashed]; + "UH01.TRO101_IN" -> "UH01.TRO101" [label="JamBuffer101"]; + "UH01.TRO102_IN" -> "UH01.TRO102" [label="JamBuffer102"]; + "UH01.EXTERN_IN" -> "UH01.TRO115" [label="JA4104_1", color="#999999"]; + "UH01.EXTERN_IN" -> "UH01.TRO133" [label="JA4302_1", color="#999999"]; + "UH01.EXTERN_IN" -> "UH01.TRO134" [label="JA4402_1", color="#999999"]; + "UH01.EXTERN_IN" -> "UH01.TRO121" [label="JA4503_1", color="#999999"]; + } + + subgraph "cluster_UH02" { + label = "UH02 (=A01+UH02-KF00)"; + style = "rounded"; + color = "#888888"; + "UH02.TRO200" [label="TRO200\n[Vario]\nTRO 200 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO201" [label="TRO201\n[1Sep]\nTRO 201 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO202" [label="TRO202\n[1Sep1Swi]\nTRO 202 (1Sep1Switch)+Scanner(BX2103)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO203" [label="TRO203\n[1Sep1Swi]\nTRO 203 (1Sep1Switch) + Scanner (BX2111)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO204" [label="TRO204\n[1Sep1Swi]\nTRO 204(1Sep1Switch) + Scanner(BX2112)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO205" [label="TRO205\n[1Sep1Swi]\nTRO 205 (1Sep1Switch) + Scanner(BX2114)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO206" [label="TRO206\n[1Sep1Swi]\nTRO 206 (1Sep1Switch)+Scanner(BX2113)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO207" [label="TRO207\n[1Sep]\nTRO 207(1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO208" [label="TRO208\n[PinStore_Auto]\nAufruf: TRO208", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO209" [label="TRO209\n[Vario]\nTRO 209 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO210" [label="TRO210\n[1Sep]\nTRO 210 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO211" [label="TRO211\n[PinStore_Auto]\nAufruf: TRO211", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO212" [label="TRO212\n[Vario]\nTRO 212 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO213" [label="TRO213\n[1Sep]\nTRO 213 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO214" [label="TRO214\n[PinStore_Auto]\nAufruf: TRO214", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO215" [label="TRO215\n[Vario]\nTRO 215 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO216" [label="TRO216\n[1Sep]\nTRO 216 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO217" [label="TRO217\n[PinStore_Auto]\nAufruf: TRO217", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO218" [label="TRO218\n[Vario]\nTRO 218 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO219" [label="TRO219\n[1Sep]\nTRO 219(1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO220" [label="TRO220\n[Vario]\nTRO 220 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO221" [label="TRO221\n[1Sep]\nTRO 221 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO222" [label="TRO222\n[1Sep1Swi]\nTRO 222 (1Sep1Switch)+Scanner(BX2121)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO223" [label="TRO223\n[1Sep1Swi]\nTRO 223 (1Sep1Switch)+Scanner(BX2126)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO224" [label="TRO224\n[1Sep1Swi]\nTRO 224 (1Sep1Switch)+Scanner(BX2127)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO225" [label="TRO225\n[1Sep1Swi]\nTRO 225(1Sep1Switch)+Scanner(BX2129)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO226" [label="TRO226\n[1Sep1Swi]\nTRO 226 (1Sep1Switch)+Scanner(BX2128)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO227" [label="TRO227\n[1Sep]\nTRO 227 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO228" [label="TRO228\n[PinStore_Auto]\nAufruf: TRO228", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO229" [label="TRO229\n[Vario]\nTRO 229 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO230" [label="TRO230\n[1Sep]\nTRO 230 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO231" [label="TRO231\n[PinStore_Auto]\nAufruf: TRO231", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO232" [label="TRO232\n[Vario]\nTRO 232 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO233" [label="TRO233\n[1Sep]\nTRO 233 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO234" [label="TRO234\n[PinStore_Auto]\nAufruf: TRO234", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO235" [label="TRO235\n[Vario]\nTRO 235 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO236" [label="TRO236\n[1Sep]\nTRO 236 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO237" [label="TRO237\n[PinStore_Auto]\nAufruf: TRO237", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO238" [label="TRO238\n[Vario]\nTRO 238 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO239" [label="TRO239\n[1Sep]\nTRO 239 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO240" [label="TRO240\n[Vario]\nTRO 240 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO241" [label="TRO241\n[1Sep]\nTRO 241(1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO242" [label="TRO242\n[1Sep1Swi]\nTRO 242 (1Sep1Switch)+Scanner(BX2130)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO243" [label="TRO243\n[1Sep1Swi]\nTRO 243 (1Sep1Switch)+Scanner(BX3137)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO244" [label="TRO244\n[1Sep1Swi]\nTRO 244 (1Sep1Switch)+Scanner(BX2136)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO245" [label="TRO245\n[1Sep1Swi]\nTRO 245 (1Sep1Switch)+Scanner(BX2138)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO246" [label="TRO246\n[1Sep1Swi]\nTRO 246 (1Sep1Switch)+Scanner(BX2137)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH02.TRO247" [label="TRO247\n[1Sep]\nTRO 247(1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO248" [label="TRO248\n[PinStore_Auto]\nAufruf: TRO248", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO249" [label="TRO249\n[Vario]\nTRO 249 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO250" [label="TRO250\n[1Sep]\nTRO 250 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO251" [label="TRO251\n[PinStore_Auto]\nAufruf: TRO251", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO252" [label="TRO252\n[Vario]\nTRO 252 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO253" [label="TRO253\n[1Sep]\nTRO 253 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO254" [label="TRO254\n[PinStore_Auto]\nAufruf: TRO254", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO255" [label="TRO255\n[Vario]\nTRO 255 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO256" [label="TRO256\n[1Sep]\nTRO 256 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO257" [label="TRO257\n[PinStore_Auto]\nAufruf: TRO257", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH02.TRO258" [label="TRO258\n[Vario]\nTRO 258 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO259" [label="TRO259\n[1Sep]\nTRO 259 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO260" [label="TRO260\n[Vario]\nTRO 260 (Vario) + Scanner (BX2115)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO261" [label="TRO261\n[1Sep]\nTRO 261 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO262" [label="TRO262\n[Vario]\nTRO 262 (Vario) + Scanner (BX2109)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO263" [label="TRO263\n[1Sep]\nTRO 263 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO264" [label="TRO264\n[Vario]\nTRO 264 (Vario) + Scanner (BX2108)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO265" [label="TRO265\n[1Sep]\nTRO 265 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO266" [label="TRO266\n[1Sep]\nTRO 266(1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO267" [label="TRO267\n[1Sep2Swi]\nTRO 267 (1Sep2Switch)+Scanner(BX2100)", shape=diamond, style=filled, fillcolor="#ffc060"]; + "UH02.TRO268" [label="TRO268\n[1Sep2Swi]\nTRO 268 (1Sep2Switch)+Scanner(BX2101)", shape=diamond, style=filled, fillcolor="#ffc060"]; + "UH02.TRO269" [label="TRO269\n[1Sep]\nTRO 269 (1Sep)+Scanner (BX2102)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO270" [label="TRO270\n[Vario]\nTRO 270 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO272" [label="TRO272\n[Vario]\nTRO 272 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH02.TRO274" [label="TRO274\n[1Sep]\nTRO 274 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.TRO275" [label="TRO275\n[1Sep]\nTRO 275 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH02.EXTERN_IN" [label="EXTERN\n(Zulauf)", shape=ellipse, style="filled,dashed", fillcolor="#f8f8f8"]; + "UH02.EXTERN_OUT" [label="EXTERN\n(Ablauf)", shape=ellipse, style="filled,dashed", fillcolor="#f8f8f8"]; + "UH02.TRO202" -> "UH02.TRO211" [label="JA1101_1 Dir2"]; + "UH02.TRO213" -> "UH02.TRO211" [label="JA1101_1"]; + "UH02.TRO211" -> "UH02.TRO208" [label="JA1101_2 Bypass", style=dashed]; + "UH02.TRO210" -> "UH02.TRO208" [label="JA1101_2"]; + "UH02.TRO201" -> "UH02.TRO202" [label="JA1102_1"]; + "UH02.TRO202" -> "UH02.TRO214" [label="JA1102_2"]; + "UH02.TRO216" -> "UH02.TRO214" [label="JA1102_2"]; + "UH02.TRO214" -> "UH02.TRO217" [label="JA1102_3 Bypass", style=dashed]; + "UH02.TRO219" -> "UH02.TRO217" [label="JA1102_3"]; + "UH02.TRO208" -> "UH02.TRO203" [label="JA1103_1"]; + "UH02.TRO211" -> "UH02.TRO204" [label="JA1103_2"]; + "UH02.TRO203" -> "UH02.TRO204" [label="JA1103_2 Dir2"]; + "UH02.TRO217" -> "UH02.TRO205" [label="JA1104_1"]; + "UH02.TRO214" -> "UH02.TRO206" [label="JA1104_2"]; + "UH02.TRO205" -> "UH02.TRO206" [label="JA1104_2"]; + "UH02.TRO204" -> "UH02.TRO207" [label="JA1104_3 Dir2"]; + "UH02.TRO206" -> "UH02.TRO207" [label="JA1104_3"]; + "UH02.TRO203" -> "UH02.TRO209" [label="JA1105_1"]; + "UH02.TRO209" -> "UH02.TRO210" [label="JA1105_2 Finger", style=dashed]; + "UH02.TRO204" -> "UH02.TRO212" [label="JA1106_1"]; + "UH02.TRO212" -> "UH02.TRO213" [label="JA1106_2 Finger", style=dashed]; + "UH02.TRO206" -> "UH02.TRO215" [label="JA1107_1 Dir2"]; + "UH02.TRO215" -> "UH02.TRO216" [label="JA1107_2 Finger", style=dashed]; + "UH02.TRO205" -> "UH02.TRO218" [label="JA1108_1 Dir2"]; + "UH02.TRO218" -> "UH02.TRO219" [label="JA1108_2 Finger", style=dashed]; + "UH02.TRO200" -> "UH02.TRO201" [label="JA1109_2 Finger", style=dashed]; + "UH02.TRO268" -> "UH02.TRO269" [label="JA1110_1 Dir3"]; + "UH02.TRO261" -> "UH02.TRO274" [label="JA1110_2"]; + "UH02.TRO269" -> "UH02.TRO274" [label="JA1110_2"]; + "UH02.TRO263" -> "UH02.TRO266" [label="JA1110_3"]; + "UH02.TRO274" -> "UH02.TRO266" [label="JA1110_3"]; + "UH02.TRO265" -> "UH02.TRO267" [label="JA1110_4"]; + "UH02.TRO266" -> "UH02.TRO267" [label="JA1110_4"]; + "UH02.TRO267" -> "UH02.TRO275" [label="JA1110_5 Dir3"]; + "UH02.TRO275" -> "UH02.TRO268" [label="JA1110_6"]; + "UH02.TRO222" -> "UH02.TRO231" [label="JA1201_1 Dir2"]; + "UH02.TRO233" -> "UH02.TRO231" [label="JA1201_1"]; + "UH02.TRO231" -> "UH02.TRO228" [label="JA1201_2 Bypass", style=dashed]; + "UH02.TRO230" -> "UH02.TRO228" [label="JA1201_2"]; + "UH02.TRO221" -> "UH02.TRO222" [label="JA1202_1"]; + "UH02.TRO222" -> "UH02.TRO234" [label="JA1202_2"]; + "UH02.TRO236" -> "UH02.TRO234" [label="JA1202_2"]; + "UH02.TRO234" -> "UH02.TRO237" [label="JA1202_3 Bypass", style=dashed]; + "UH02.TRO239" -> "UH02.TRO237" [label="JA1202_3"]; + "UH02.TRO228" -> "UH02.TRO223" [label="JA1203_1"]; + "UH02.TRO231" -> "UH02.TRO224" [label="JA1203_2"]; + "UH02.TRO223" -> "UH02.TRO224" [label="JA1203_2 Dir2"]; + "UH02.TRO237" -> "UH02.TRO225" [label="JA1204_1"]; + "UH02.TRO234" -> "UH02.TRO226" [label="JA1204_2"]; + "UH02.TRO225" -> "UH02.TRO226" [label="JA1204_2"]; + "UH02.TRO224" -> "UH02.TRO227" [label="JA1204_3 Dir2"]; + "UH02.TRO226" -> "UH02.TRO227" [label="JA1204_3"]; + "UH02.TRO223" -> "UH02.TRO229" [label="JA1205_1"]; + "UH02.TRO229" -> "UH02.TRO230" [label="JA1205_2 Finger", style=dashed]; + "UH02.TRO224" -> "UH02.TRO232" [label="JA1206_1"]; + "UH02.TRO232" -> "UH02.TRO233" [label="JA1206_2 Finger", style=dashed]; + "UH02.TRO226" -> "UH02.TRO235" [label="JA1207_1 Dir2"]; + "UH02.TRO235" -> "UH02.TRO236" [label="JA1207_2 Finger", style=dashed]; + "UH02.TRO225" -> "UH02.TRO238" [label="JA1208_1 Dir2"]; + "UH02.TRO238" -> "UH02.TRO239" [label="JA1208_2 Finger", style=dashed]; + "UH02.TRO220" -> "UH02.TRO221" [label="JA1209_2 Finger", style=dashed]; + "UH02.TRO248" -> "UH02.TRO243" [label="JA1301_1"]; + "UH02.TRO251" -> "UH02.TRO244" [label="JA1301_2"]; + "UH02.TRO243" -> "UH02.TRO244" [label="JA1301_2"]; + "UH02.TRO257" -> "UH02.TRO245" [label="JA1302_1"]; + "UH02.TRO254" -> "UH02.TRO246" [label="JA1302_2"]; + "UH02.TRO245" -> "UH02.TRO246" [label="JA1302_2 Dir2"]; + "UH02.TRO242" -> "UH02.TRO251" [label="JA1303_1"]; + "UH02.TRO253" -> "UH02.TRO251" [label="JA1303_1"]; + "UH02.TRO251" -> "UH02.TRO248" [label="JA1303_2 Bypass", style=dashed]; + "UH02.TRO250" -> "UH02.TRO248" [label="JA1303_2"]; + "UH02.TRO241" -> "UH02.TRO242" [label="JA1304_1"]; + "UH02.TRO242" -> "UH02.TRO254" [label="JA1304_2 Dir2"]; + "UH02.TRO256" -> "UH02.TRO254" [label="JA1304_2"]; + "UH02.TRO254" -> "UH02.TRO257" [label="JA1304_3 Bypass", style=dashed]; + "UH02.TRO259" -> "UH02.TRO257" [label="JA1304_3"]; + "UH02.TRO243" -> "UH02.TRO249" [label="JA1305_1 Dir2"]; + "UH02.TRO249" -> "UH02.TRO250" [label="JA1305_2 Finger", style=dashed]; + "UH02.TRO244" -> "UH02.TRO252" [label="JA1306_1 Dir2"]; + "UH02.TRO252" -> "UH02.TRO253" [label="JA1306_2 Finger", style=dashed]; + "UH02.TRO246" -> "UH02.TRO255" [label="JA1307_1"]; + "UH02.TRO255" -> "UH02.TRO256" [label="JA1307_2 Finger", style=dashed]; + "UH02.TRO245" -> "UH02.TRO258" [label="JA1308_1"]; + "UH02.TRO258" -> "UH02.TRO259" [label="JA1308_2 Finger", style=dashed]; + "UH02.TRO240" -> "UH02.TRO241" [label="JA1309_2 Finger", style=dashed]; + "UH02.TRO264" -> "UH02.TRO265" [label="JA1401_2 Finger", style=dashed]; + "UH02.TRO262" -> "UH02.TRO263" [label="JA1501_2 Finger", style=dashed]; + "UH02.TRO260" -> "UH02.TRO261" [label="JA1601_2 Finger", style=dashed]; + "UH02.EXTERN_IN" -> "UH02.TRO200" [label="JA1109_1", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO220" [label="JA1209_1", color="#999999"]; + "UH02.TRO244" -> "UH02.EXTERN_OUT" [label="JA1302_3", color="#999999"]; + "UH02.TRO246" -> "UH02.EXTERN_OUT" [label="JA1302_3", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO240" [label="JA1309_1", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO264" [label="JA1401_1", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO262" [label="JA1501_1", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO260" [label="JA1601_1", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO272" [label="JA1801_1", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO270" [label="JA4701_1", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO208" [label="Storage1.1.1", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO211" [label="Storage1.1.2", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO214" [label="Storage1.1.3", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO217" [label="Storage1.1.4", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO228" [label="Storage1.2.1", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO231" [label="Storage1.2.2", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO234" [label="Storage1.2.3", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO237" [label="Storage1.2.4", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO248" [label="Storage1.3.1", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO251" [label="Storage1.3.2", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO254" [label="Storage1.3.3", color="#999999"]; + "UH02.EXTERN_IN" -> "UH02.TRO257" [label="Storage1.3.4", color="#999999"]; + "UH02.TRO207" -> "UH02.EXTERN_OUT" [label="IO_Device_UH02_TO_UH01.stCARRIER_INFO", color="#999999"]; + "UH02.TRO227" -> "UH02.EXTERN_OUT" [label="IO_Device_UH02_TO_UH01.stCARRIER_INFO_1", color="#999999"]; + "UH02.TRO247" -> "UH02.EXTERN_OUT" [label="IO_Device_UH02_TO_UH01.stCARRIER_INFO_2", color="#999999"]; + } + + subgraph "cluster_UH03" { + label = "UH03 (=A01+UH03-KF00)"; + style = "rounded"; + color = "#888888"; + "UH03.TRO300" [label="TRO300\n[Vario]\nTRO 300 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO301" [label="TRO301\n[1Sep]\nTRO 301(1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO302" [label="TRO302\n[Vario]\nTRO 302 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO303" [label="TRO303\n[Vario]\nTRO 303 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO304" [label="TRO304\n[1Sep]\nTRO 304(1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO305" [label="TRO305\n[Vario]\nTRO 305 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO306" [label="TRO306\n[Vario]\nTRO 306 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO307" [label="TRO307\n[Vario]\nTRO 307 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO308" [label="TRO308\n[Vario]\nTRO 308 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO309" [label="TRO309\n[1Sep]\nTRO 309 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO310" [label="TRO310\n[1Sep]\nTRO 310 (1Sep)+Scanner (BX3102)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO311" [label="TRO311\n[1Sep]\nTRO 311 (1Sep)+Scanner(BX3101)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO312" [label="TRO312\n[1Sep]\nTRO 312 (1Sep)+Scanner(BX3100)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO313" [label="TRO313\n[1Sep1Swi]\nTRO 313 (1Sep1Switch)+Scanner(BX3103)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO314" [label="TRO314\n[1Sep1Swi]\nTRO 314 (1Sep1Switch)+Scanner(BX3104)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO315" [label="TRO315\n[1Sep]\nTRO 315 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO316" [label="TRO316\n[1Sep]\nTRO 316 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO317" [label="TRO317\n[1Sep1Swi]\nTRO 317 (1Sep1Switch)+Scanner(BX3105)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO318" [label="TRO318\n[1Sep1Swi]\nTRO 318 (1Sep1Switch) + Scanner(BX3106)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO319" [label="TRO319\n[1Sep1Swi]\nTRO 319 (1Sep1Switch) + Scanner (BX3111)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO320" [label="TRO320\n[1Sep1Swi]\nTRO 320 (1Sep1Switch) + Scanner(BX3112)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO321" [label="TRO321\n[1Sep1Swi]\nTRO 321 (1Sep1Switch) + Scanner(BX3114)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO322" [label="TRO322\n[1Sep1Swi]\nTRO 322 (1Sep1Switch)+Scanner(BX3113)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO323" [label="TRO323\n[1Sep]\nTRO 323 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO324" [label="TRO324\n[Vario]\nTRO 324 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO325" [label="TRO325\n[1Sep]\nTRO 325 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO326" [label="TRO326\n[1Sep]\nTRO 326 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO327" [label="TRO327\n[PinStore_Auto]\nAufruf: TRO327", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO328" [label="TRO328\n[Vario]\nTRO 328 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO329" [label="TRO329\n[1Sep]\nTRO 329 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO330" [label="TRO330\n[PinStore_Auto]\nAufruf: TRO330", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO331" [label="TRO331\n[Vario]\nTRO 331 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO332" [label="TRO332\n[1Sep]\nTRO 332 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO333" [label="TRO333\n[PinStore_Auto]\nAufruf: TRO333", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO334" [label="TRO334\n[Vario]\nTRO 334 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO335" [label="TRO335\n[1Sep]\nTRO 335 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO336" [label="TRO336\n[PinStore_Auto]\nAufruf: TRO336", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO337" [label="TRO337\n[Vario]\nTRO 337 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO338" [label="TRO338\n[1Sep]\nTRO 338 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO339" [label="TRO339\n[1Sep1Swi]\nTRO 339 (1Sep1Switch)+Scanner(BX3120)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO340" [label="TRO340\n[1Sep1Swi]\nTRO 340 (1Sep1Switch)+Scanner(BX3121)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO341" [label="TRO341\n[1Sep1Swi]\nTRO 341 (1Sep1Switch)+Scanner(BX3126)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO342" [label="TRO342\n[1Sep1Swi]\nTRO 342 (1Sep1Switch)+Scanner(BX3127)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO343" [label="TRO343\n[1Sep1Swi]\nTRO 343 (1Sep1Switch)+Scanner(BX3129)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO344" [label="TRO344\n[1Sep1Swi]\nTRO 344 (1Sep1Switch)+Scanner(BX3128)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO345" [label="TRO345\n[1Sep]\nTRO 345 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO346" [label="TRO346\n[Vario]\nTRO 346 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO347" [label="TRO347\n[1Sep]\nTRO 347 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO348" [label="TRO348\n[1Sep]\nTRO 348 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO349" [label="TRO349\n[PinStore_Auto]\nAufruf: TRO349", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO350" [label="TRO350\n[Vario]\nTRO 350 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO351" [label="TRO351\n[1Sep]\nTRO 351 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO352" [label="TRO352\n[PinStore_Auto]\nAufruf: TRO352", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO353" [label="TRO353\n[Vario]\nTRO 353 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO354" [label="TRO354\n[1Sep]\nTRO 354 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO355" [label="TRO355\n[PinStore_Auto]\nAufruf: TRO355", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO356" [label="TRO356\n[Vario]\nTRO 356 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO357" [label="TRO357\n[1Sep]\nTRO 357 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO358" [label="TRO358\n[PinStore_Auto]\nAufruf: TRO358", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO359" [label="TRO359\n[Vario]\nTRO 359 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO360" [label="TRO360\n[1Sep]\nTRO 360 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO361" [label="TRO361\n[1Sep1Swi]\nTRO 361 (1Sep1Switch)+Scanner(BX3131)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO362" [label="TRO362\n[1Sep1Swi]\nTRO 362 (1Sep1Switch)+Scanner(BX3132)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO363" [label="TRO363\n[1Sep1Swi]\nTRO 363 (1Sep1Switch)+Scanner(BX3137)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO364" [label="TRO364\n[1Sep1Swi]\nTRO 364 (1Sep1Switch)+Scanner(BX3138)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO365" [label="TRO365\n[1Sep1Swi]\nTRO 365 (1Sep1Switch)+Scanner(BX3140)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO366" [label="TRO366\n[1Sep1Swi]\nTRO 366 (1Sep1Switch)+Scanner(BX3139)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH03.TRO367" [label="TRO367\n[1Sep]\nTRO 367 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO368" [label="TRO368\n[Vario]\nTRO 368 (Vario, from Lvl1)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO369" [label="TRO369\n[1Sep]\nTRO 369 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO370" [label="TRO370\n[1Sep]\nTRO 370 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO371" [label="TRO371\n[PinStore_Auto]\nAufruf: TRO371", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO372" [label="TRO372\n[Vario]\nTRO 372 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO373" [label="TRO373\n[1Sep]\nTRO 373 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO374" [label="TRO374\n[PinStore_Auto]\nAufruf: TRO374", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO375" [label="TRO375\n[Vario]\nTRO 375 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO376" [label="TRO376\n[1Sep]\nTRO 376 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO377" [label="TRO377\n[PinStore_Auto]\nAufruf: TRO377", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO378" [label="TRO378\n[Vario]\nTRO 378 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO379" [label="TRO379\n[1Sep]\nTRO 379 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO380" [label="TRO380\n[PinStore_Auto]\nAufruf: TRO380", shape=box, style=filled, fillcolor="#f0f0f0"]; + "UH03.TRO381" [label="TRO381\n[Vario]\nTRO 381 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH03.TRO382" [label="TRO382\n[1Sep]\nTRO 382 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.TRO386" [label="TRO386\n[1Sep]\nTRO 386 (1Sep) - kam später dazu", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH03.EXTERN_IN" [label="EXTERN\n(Zulauf)", shape=ellipse, style="filled,dashed", fillcolor="#f8f8f8"]; + "UH03.EXTERN_OUT" [label="EXTERN\n(Ablauf)", shape=ellipse, style="filled,dashed", fillcolor="#f8f8f8"]; + "UH03.TRO318" -> "UH03.TRO330" [label="JA2101_1 Dir2"]; + "UH03.TRO332" -> "UH03.TRO330" [label="JA2101_1"]; + "UH03.TRO330" -> "UH03.TRO327" [label="JA2101_2 Bypass", style=dashed]; + "UH03.TRO329" -> "UH03.TRO327" [label="JA2101_2"]; + "UH03.TRO315" -> "UH03.TRO317" [label="JA2102_1"]; + "UH03.TRO317" -> "UH03.TRO318" [label="JA2102_2"]; + "UH03.TRO318" -> "UH03.TRO333" [label="JA2102_3"]; + "UH03.TRO335" -> "UH03.TRO333" [label="JA2102_3"]; + "UH03.TRO333" -> "UH03.TRO336" [label="JA2102_4 Bypass", style=dashed]; + "UH03.TRO338" -> "UH03.TRO336" [label="JA2102_4"]; + "UH03.TRO327" -> "UH03.TRO319" [label="JA2103_1"]; + "UH03.TRO330" -> "UH03.TRO320" [label="JA2103_2"]; + "UH03.TRO319" -> "UH03.TRO320" [label="JA2103_2 Dir2"]; + "UH03.TRO336" -> "UH03.TRO321" [label="JA2104_1"]; + "UH03.TRO333" -> "UH03.TRO322" [label="JA2104_2"]; + "UH03.TRO321" -> "UH03.TRO322" [label="JA2104_2"]; + "UH03.TRO320" -> "UH03.TRO323" [label="JA2104_3 Dir2"]; + "UH03.TRO322" -> "UH03.TRO323" [label="JA2104_3"]; + "UH03.TRO323" -> "UH03.TRO326" [label="JA2104_4"]; + "UH03.TRO325" -> "UH03.TRO326" [label="JA2104_4"]; + "UH03.TRO319" -> "UH03.TRO328" [label="JA2105_1"]; + "UH03.TRO328" -> "UH03.TRO329" [label="JA2105_2 Finger", style=dashed]; + "UH03.TRO320" -> "UH03.TRO331" [label="JA2106_1"]; + "UH03.TRO331" -> "UH03.TRO332" [label="JA2106_2 Finger", style=dashed]; + "UH03.TRO322" -> "UH03.TRO334" [label="JA2107_1 Dir2"]; + "UH03.TRO334" -> "UH03.TRO335" [label="JA2107_2 Finger", style=dashed]; + "UH03.TRO321" -> "UH03.TRO337" [label="JA2108_1 Dir2"]; + "UH03.TRO337" -> "UH03.TRO338" [label="JA2108_2 Finger", style=dashed]; + "UH03.TRO324" -> "UH03.TRO325" [label="JA2109_2 Finger", style=dashed]; + "UH03.TRO386" -> "UH03.TRO310" [label="JA2110_1"]; + "UH03.TRO310" -> "UH03.TRO313" [label="JA2110_2"]; + "UH03.TRO311" -> "UH03.TRO313" [label="JA2110_2"]; + "UH03.TRO312" -> "UH03.TRO313" [label="JA2110_2"]; + "UH03.TRO313" -> "UH03.TRO314" [label="JA2110_3 Dir2"]; + "UH03.TRO314" -> "UH03.TRO315" [label="JA2110_4 Dir2"]; + "UH03.TRO309" -> "UH03.TRO386" [label="JA2110_5"]; + "UH03.TRO308" -> "UH03.TRO309" [label="JA2111_2 Finger", style=dashed]; + "UH03.TRO313" -> "UH03.TRO316" [label="JA2112_1"]; + "UH03.TRO340" -> "UH03.TRO352" [label="JA2201_1 Dir2"]; + "UH03.TRO354" -> "UH03.TRO352" [label="JA2201_1"]; + "UH03.TRO352" -> "UH03.TRO349" [label="JA2201_2 Bypass", style=dashed]; + "UH03.TRO351" -> "UH03.TRO349" [label="JA2201_2"]; + "UH03.TRO314" -> "UH03.TRO339" [label="JA2202_1"]; + "UH03.TRO339" -> "UH03.TRO340" [label="JA2202_2"]; + "UH03.TRO340" -> "UH03.TRO355" [label="JA2202_3"]; + "UH03.TRO357" -> "UH03.TRO355" [label="JA2202_3"]; + "UH03.TRO355" -> "UH03.TRO358" [label="JA2202_4 Bypass", style=dashed]; + "UH03.TRO360" -> "UH03.TRO358" [label="JA2202_4"]; + "UH03.TRO349" -> "UH03.TRO341" [label="JA2203_1"]; + "UH03.TRO352" -> "UH03.TRO342" [label="JA2203_2"]; + "UH03.TRO341" -> "UH03.TRO342" [label="JA2203_2 Dir2"]; + "UH03.TRO358" -> "UH03.TRO343" [label="JA2204_1"]; + "UH03.TRO355" -> "UH03.TRO344" [label="JA2204_2"]; + "UH03.TRO343" -> "UH03.TRO344" [label="JA2204_2"]; + "UH03.TRO342" -> "UH03.TRO345" [label="JA2204_3 Dir2"]; + "UH03.TRO344" -> "UH03.TRO345" [label="JA2204_3"]; + "UH03.TRO345" -> "UH03.TRO348" [label="JA2204_4"]; + "UH03.TRO347" -> "UH03.TRO348" [label="JA2204_4"]; + "UH03.TRO341" -> "UH03.TRO350" [label="JA2205_1"]; + "UH03.TRO350" -> "UH03.TRO351" [label="JA2205_2 Finger", style=dashed]; + "UH03.TRO342" -> "UH03.TRO353" [label="JA2206_1"]; + "UH03.TRO353" -> "UH03.TRO354" [label="JA2206_2 Finger", style=dashed]; + "UH03.TRO344" -> "UH03.TRO356" [label="JA2207_1 Dir2"]; + "UH03.TRO356" -> "UH03.TRO357" [label="JA2207_2 Finger", style=dashed]; + "UH03.TRO343" -> "UH03.TRO359" [label="JA2208_1 Dir2"]; + "UH03.TRO359" -> "UH03.TRO360" [label="JA2208_2 Finger", style=dashed]; + "UH03.TRO346" -> "UH03.TRO347" [label="JA2209_2 Finger", style=dashed]; + "UH03.TRO371" -> "UH03.TRO363" [label="JA2301_1"]; + "UH03.TRO374" -> "UH03.TRO364" [label="JA2301_2"]; + "UH03.TRO363" -> "UH03.TRO364" [label="JA2301_2"]; + "UH03.TRO380" -> "UH03.TRO365" [label="JA2302_1"]; + "UH03.TRO377" -> "UH03.TRO366" [label="JA2302_2"]; + "UH03.TRO365" -> "UH03.TRO366" [label="JA2302_2 Dir2"]; + "UH03.TRO364" -> "UH03.TRO367" [label="JA2302_3"]; + "UH03.TRO366" -> "UH03.TRO367" [label="JA2302_3 Dir2"]; + "UH03.TRO367" -> "UH03.TRO370" [label="JA2302_4"]; + "UH03.TRO369" -> "UH03.TRO370" [label="JA2302_4"]; + "UH03.TRO362" -> "UH03.TRO374" [label="JA2303_1"]; + "UH03.TRO376" -> "UH03.TRO374" [label="JA2303_1"]; + "UH03.TRO374" -> "UH03.TRO371" [label="JA2303_2 Bypass", style=dashed]; + "UH03.TRO373" -> "UH03.TRO371" [label="JA2303_2"]; + "UH03.TRO316" -> "UH03.TRO361" [label="JA2304_1"]; + "UH03.TRO361" -> "UH03.TRO362" [label="JA2304_2 Dir2"]; + "UH03.TRO362" -> "UH03.TRO377" [label="JA2304_3 Dir2"]; + "UH03.TRO379" -> "UH03.TRO377" [label="JA2304_3"]; + "UH03.TRO377" -> "UH03.TRO380" [label="JA2304_4 Bypass", style=dashed]; + "UH03.TRO382" -> "UH03.TRO380" [label="JA2304_4"]; + "UH03.TRO363" -> "UH03.TRO372" [label="JA2305_1 Dir2"]; + "UH03.TRO372" -> "UH03.TRO373" [label="JA2305_2 Finger", style=dashed]; + "UH03.TRO364" -> "UH03.TRO375" [label="JA2306_1 Dir2"]; + "UH03.TRO375" -> "UH03.TRO376" [label="JA2306_2 Finger", style=dashed]; + "UH03.TRO366" -> "UH03.TRO378" [label="JA2307_1"]; + "UH03.TRO378" -> "UH03.TRO379" [label="JA2307_2 Finger", style=dashed]; + "UH03.TRO365" -> "UH03.TRO381" [label="JA2308_1"]; + "UH03.TRO381" -> "UH03.TRO382" [label="JA2308_2 Finger", style=dashed]; + "UH03.TRO368" -> "UH03.TRO369" [label="JA2309_2 Finger", style=dashed]; + "UH03.TRO300" -> "UH03.TRO302" [label="JA4101_1 Finger", style=dashed]; + "UH03.TRO301" -> "UH03.TRO302" [label="JA4101_1"]; + "UH03.TRO302" -> "UH03.TRO311" [label="JA4101_2 Finger", style=dashed]; + "UH03.TRO303" -> "UH03.TRO305" [label="JA4201_1 Finger", style=dashed]; + "UH03.TRO304" -> "UH03.TRO305" [label="JA4201_1"]; + "UH03.TRO305" -> "UH03.TRO312" [label="JA4201_2 Finger", style=dashed]; + "UH03.TRO336" -> "UH03.EXTERN_OUT" [label="JA2102_5", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO324" [label="JA2109_1", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO308" [label="JA2111_1", color="#999999"]; + "UH03.TRO358" -> "UH03.EXTERN_OUT" [label="JA2202_5", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO346" [label="JA2209_1", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO368" [label="JA2309_1", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO300" [label="JA4102_1", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO301" [label="JA4102_2", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO303" [label="JA4202_1", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO304" [label="JA4202_2", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO306" [label="JA4301_1", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO307" [label="JA4401_1", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO327" [label="Storage2.1.1", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO330" [label="Storage2.1.2", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO333" [label="Storage2.1.3", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO336" [label="Storage2.1.4", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO349" [label="Storage2.2.1", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO352" [label="Storage2.2.2", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO355" [label="Storage2.2.3", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO358" [label="Storage2.2.4", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO371" [label="Storage2.3.1", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO374" [label="Storage2.3.2", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO377" [label="Storage2.3.3", color="#999999"]; + "UH03.EXTERN_IN" -> "UH03.TRO380" [label="Storage2.3.4", color="#999999"]; + "UH03.TRO326" -> "UH03.EXTERN_OUT" [label="IO_Device_UH03_TO_UH01.stCARRIER_INFO", color="#999999"]; + "UH03.TRO348" -> "UH03.EXTERN_OUT" [label="IO_Device_UH03_TO_UH01.stCARRIER_INFO_1", color="#999999"]; + "UH03.TRO370" -> "UH03.EXTERN_OUT" [label="IO_Device_UH03_TO_UH01.stCARRIER_INFO_2", color="#999999"]; + "UH03.TRO317" -> "UH03.EXTERN_OUT" [label="IO_Device_UH03_TO_UH01.stCarrierL2toL1", color="#999999"]; + "UH03.TRO339" -> "UH03.EXTERN_OUT" [label="IO_Device_UH03_TO_UH01.stCarrierL2toL1_2", color="#999999"]; + "UH03.TRO361" -> "UH03.EXTERN_OUT" [label="IO_Device_UH03_TO_UH01.stCarrierL2toL1_3", color="#999999"]; + } + + subgraph "cluster_UH04" { + label = "UH04 (=A01+UH04-KF00)"; + style = "rounded"; + color = "#888888"; + "UH04.TRO400" [label="TRO400\n[Vario]\nTRO 400 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH04.TRO401" [label="TRO401\n[Vario]\nTRO 401 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH04.TRO402" [label="TRO402\n[1Sep]\nTRO 402 (1Sep) (Vor Brandschutztor)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH04.TRO403" [label="TRO403\n[Vario]\nTRO 403 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH04.TRO404" [label="TRO404\n[1Sep]\nTRO 404 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH04.TRO405" [label="TRO405\n[1Sep1Swi]\nTRO 405 (1Sep1Switch) + Scanner (BX4100) + Behangskontrolle", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH04.TRO406" [label="TRO406\n[1Sep]\nTRO 406 (1Sep) + Scanner (BX4101)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH04.TRO407" [label="TRO407\n[1Sep1Swi]\nTRO 407 (1Sep1Switch) + Scanner (BX4102)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH04.TRO408" [label="TRO408\n[Vario]\nTRO 408 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH04.TRO409" [label="TRO409\n[1Sep]\nTRO 409 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH04.TRO410" [label="TRO410\n[1Sep1Swi]\nTRO 410 (1Sep1Switch) + Scanner (BX4104)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH04.TRO411" [label="TRO411\n[Vario]\nTRO 411 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH04.TRO412" [label="TRO412\n[1Sep]\nTRO 412 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH04.TRO413" [label="TRO413\n[1Sep1Swi]\nTRO 413(1Sep1Switch)+Scanner(BX4106)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH04.TRO414" [label="TRO414\n[Vario]\nTRO 414 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH04.TRO415" [label="TRO415\n[1Sep]\nTRO 415 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH04.TRO416" [label="TRO416\n[1Sep]\nTRO 416 (1Sep) + Beladeprüfung", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH04.TRO417" [label="TRO417\n[1Sep]\nTRO 417 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH04.TRO418" [label="TRO418\n[Vario]\nTRO 418 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH04.TRO420" [label="TRO420\n[Vario]\nTRO 420 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH04.TRO421" [label="TRO421\n[Vario_workStation]\nTRO 421 (Vario)", shape=parallelogram, style=filled, fillcolor="#c0f0f0"]; + "UH04.TRO422" [label="TRO422\n[Vario_workStation]\nTRO 422 (Vario)", shape=parallelogram, style=filled, fillcolor="#c0f0f0"]; + "UH04.TRO423" [label="TRO423\n[Vario_workStation]\nTRO 423 (Vario)", shape=parallelogram, style=filled, fillcolor="#c0f0f0"]; + "UH04.TRO424" [label="TRO424\n[1Sep]\nTRO 424 (1Sep) vor Behangskontrolle", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH04.EXTERN_IN" [label="EXTERN\n(Zulauf)", shape=ellipse, style="filled,dashed", fillcolor="#f8f8f8"]; + "UH04.EXTERN_OUT" [label="EXTERN\n(Ablauf)", shape=ellipse, style="filled,dashed", fillcolor="#f8f8f8"]; + "UH04.TRO400" -> "UH04.TRO401" [label="JA4001_1 Finger", style=dashed]; + "UH04.TRO401" -> "UH04.TRO402" [label="JA4001_2 Finger", style=dashed]; + "UH04.TRO402" -> "UH04.TRO403" [label="JA4002_1"]; + "UH04.TRO403" -> "UH04.TRO404" [label="JA4002_2 Finger", style=dashed]; + "UH04.TRO424" -> "UH04.TRO405" [label="JA4003_1"]; + "UH04.TRO405" -> "UH04.TRO406" [label="JA4003_2 Dir2"]; + "UH04.TRO406" -> "UH04.TRO407" [label="JA4003_3"]; + "UH04.TRO407" -> "UH04.TRO410" [label="JA4003_4 Dir2"]; + "UH04.TRO409" -> "UH04.TRO410" [label="JA4003_4"]; + "UH04.TRO410" -> "UH04.TRO413" [label="JA4003_5 Dir2"]; + "UH04.TRO412" -> "UH04.TRO413" [label="JA4003_5"]; + "UH04.TRO413" -> "UH04.TRO416" [label="JA4003_6 Dir2"]; + "UH04.TRO415" -> "UH04.TRO416" [label="JA4003_6"]; + "UH04.TRO416" -> "UH04.TRO417" [label="JA4003_7"]; + "UH04.TRO404" -> "UH04.TRO424" [label="JA4003_8"]; + "UH04.TRO417" -> "UH04.TRO424" [label="JA4003_8"]; + "UH04.TRO407" -> "UH04.TRO408" [label="JA4004_1"]; + "UH04.TRO408" -> "UH04.TRO421" [label="JA4004_2 Finger", style=dashed]; + "UH04.TRO410" -> "UH04.TRO411" [label="JA4006_1"]; + "UH04.TRO411" -> "UH04.TRO422" [label="JA4006_2 Finger", style=dashed]; + "UH04.TRO422" -> "UH04.TRO412" [label="JA4007_1 Finger", style=dashed]; + "UH04.TRO413" -> "UH04.TRO414" [label="JA4008_1"]; + "UH04.TRO414" -> "UH04.TRO423" [label="JA4008_2 Finger", style=dashed]; + "UH04.TRO423" -> "UH04.TRO415" [label="JA4009_1 Finger", style=dashed]; + "UH04.TRO418" -> "UH04.TRO420" [label="JA4011_1 Finger", style=dashed]; + "UH04.EXTERN_IN" -> "UH04.TRO400" [label="JA4000_1", color="#999999"]; + "UH04.TRO421" -> "UH04.EXTERN_OUT" [label="JA4005_1", color="#999999"]; + "UH04.EXTERN_IN" -> "UH04.TRO418" [label="JA4010_1", color="#999999"]; + } + + subgraph "cluster_UH05" { + label = "UH05 (=A01+UH05-KF00)"; + style = "rounded"; + color = "#888888"; + "UH05.TRO500" [label="TRO500\n[Vario]\nTRO 500 (Vario) - Stand: Vorbereitet für Umbau!", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH05.TRO501" [label="TRO501\n[1Sep]\nTRO 501 (1Sep) + Scanner (BX5101)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO502" [label="TRO502\n[Vario]\nTRO 502 (Vario) - Stand: Vorbereitet für Umbau!", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH05.TRO503" [label="TRO503\n[1Sep]\nTRO 503 (1Sep)+ Scanner (BX5100)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO504" [label="TRO504\n[1Sep]\nTRO 504 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO505" [label="TRO505\n[1Sep1Swi]\nTRO 505 (1Sep1Switch) + Scanner (BX5102)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH05.TRO506" [label="TRO506\n[Vario]\nTRO 506 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH05.TRO507" [label="TRO507\n[1Sep]\nTRO 507 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO508" [label="TRO508\n[Vario]\nTRO 508 (Vario)+Scanner(BX5103)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH05.TRO509" [label="TRO509\n[1Sep]\nTRO 509 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO510" [label="TRO510\n[1Sep1Swi]\nTRO 510 (1Sep1Switch) + Scanner (BX5104)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH05.TRO511" [label="TRO511\n[1Sep]\nTRO 511 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO512" [label="TRO512\n[Vario]\nTRO 512 (Vario)+Scanner(BX5105)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH05.TRO513" [label="TRO513\n[1Sep]\nTRO 513 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO514" [label="TRO514\n[1Sep1Swi]\nTRO 514 (1Sep1Switch) + Scanner (BX5106)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH05.TRO515" [label="TRO515\n[1Sep]\nTRO 515 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO516" [label="TRO516\n[Vario]\nTRO 516(Vario)+Scanner(BX5107)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH05.TRO517" [label="TRO517\n[1Sep]\nTRO 517 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO518" [label="TRO518\n[1Sep1Swi]\nTRO 518 (1Sep1Switch) + Scanner (BX5108)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH05.TRO519" [label="TRO519\n[1Sep]\nTRO 519 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO520" [label="TRO520\n[Vario]\nTRO 520 (Vario)+Scanner(BX5109)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH05.TRO521" [label="TRO521\n[1Sep]\nTRO 521(1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO522" [label="TRO522\n[1Sep1Swi]\nTRO 522 (1Sep1Switch) + Scanner (BX5110)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH05.TRO523" [label="TRO523\n[1Sep]\nTRO 523 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO524" [label="TRO524\n[Vario]\nTRO 524 (Vario)+Scanner(BX5231)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH05.TRO525" [label="TRO525\n[1Sep]\nTRO 525(1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO526" [label="TRO526\n[1Sep]\nTRO 526 (1Sep) + Scanner (BX5112)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO527" [label="TRO527\n[1Sep1Swi]\nTRO 527 (1Sep1Switch)", shape=diamond, style=filled, fillcolor="#ffe4a0"]; + "UH05.TRO528" [label="TRO528\n[1Sep]\nTRO 528 (1Sep)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO529" [label="TRO529\n[1Sep]\nTRO 529 (1Sep) + Scanner (BX5113)", shape=box, style=filled, fillcolor="#d4e8ff"]; + "UH05.TRO530" [label="TRO530\n[Vario]\nTRO 530 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH05.TRO531" [label="TRO531\n[Vario]\nTRO 531 (Vario)", shape=parallelogram, style=filled, fillcolor="#e8d4f0"]; + "UH05.EXTERN_IN" [label="EXTERN\n(Zulauf)", shape=ellipse, style="filled,dashed", fillcolor="#f8f8f8"]; + "UH05.EXTERN_OUT" [label="EXTERN\n(Ablauf)", shape=ellipse, style="filled,dashed", fillcolor="#f8f8f8"]; + "UH05.TRO502" -> "UH05.TRO531" [label="JA5000_2 Finger", style=dashed]; + "UH05.TRO531" -> "UH05.TRO503" [label="JA5000_3 Finger", style=dashed]; + "UH05.TRO500" -> "UH05.TRO530" [label="JA5001_2 Finger", style=dashed]; + "UH05.TRO530" -> "UH05.TRO501" [label="JA5001_3 Finger", style=dashed]; + "UH05.TRO501" -> "UH05.TRO504" [label="JA5002_1"]; + "UH05.TRO503" -> "UH05.TRO504" [label="JA5002_1"]; + "UH05.TRO529" -> "UH05.TRO504" [label="JA5002_1"]; + "UH05.TRO528" -> "UH05.TRO529" [label="JA5002_10"]; + "UH05.TRO504" -> "UH05.TRO505" [label="JA5002_2"]; + "UH05.TRO505" -> "UH05.TRO510" [label="JA5002_3 Dir2"]; + "UH05.TRO509" -> "UH05.TRO510" [label="JA5002_3"]; + "UH05.TRO510" -> "UH05.TRO514" [label="JA5002_4 Dir2"]; + "UH05.TRO513" -> "UH05.TRO514" [label="JA5002_4"]; + "UH05.TRO514" -> "UH05.TRO518" [label="JA5002_5 Dir2"]; + "UH05.TRO517" -> "UH05.TRO518" [label="JA5002_5"]; + "UH05.TRO518" -> "UH05.TRO522" [label="JA5002_6 Dir2"]; + "UH05.TRO521" -> "UH05.TRO522" [label="JA5002_6"]; + "UH05.TRO522" -> "UH05.TRO526" [label="JA5002_7 Dir2"]; + "UH05.TRO525" -> "UH05.TRO526" [label="JA5002_7"]; + "UH05.TRO526" -> "UH05.TRO527" [label="JA5002_8"]; + "UH05.TRO527" -> "UH05.TRO528" [label="JA5002_9 Dir2"]; + "UH05.TRO505" -> "UH05.TRO506" [label="JA5003_1"]; + "UH05.TRO506" -> "UH05.TRO507" [label="JA5003_2 Finger", style=dashed]; + "UH05.TRO507" -> "UH05.TRO508" [label="JA5004_1"]; + "UH05.TRO510" -> "UH05.TRO511" [label="JA5005_1"]; + "UH05.TRO511" -> "UH05.TRO512" [label="JA5005_2"]; + "UH05.TRO514" -> "UH05.TRO515" [label="JA5006_1"]; + "UH05.TRO515" -> "UH05.TRO516" [label="JA5006_2"]; + "UH05.TRO518" -> "UH05.TRO519" [label="JA5007_1"]; + "UH05.TRO519" -> "UH05.TRO520" [label="JA5007_2"]; + "UH05.TRO522" -> "UH05.TRO523" [label="JA5008_1"]; + "UH05.TRO523" -> "UH05.TRO524" [label="JA5008_2"]; + "UH05.EXTERN_IN" -> "UH05.TRO502" [label="JA5000_1", color="#999999"]; + "UH05.EXTERN_IN" -> "UH05.TRO500" [label="JA5001_1", color="#999999"]; + "UH05.TRO508" -> "UH05.EXTERN_OUT" [label="JA5004_2", color="#999999"]; + "UH05.TRO512" -> "UH05.EXTERN_OUT" [label="JA5005_3", color="#999999"]; + "UH05.TRO516" -> "UH05.EXTERN_OUT" [label="JA5006_3", color="#999999"]; + "UH05.TRO520" -> "UH05.EXTERN_OUT" [label="JA5007_3", color="#999999"]; + "UH05.TRO524" -> "UH05.EXTERN_OUT" [label="JA5008_3", color="#999999"]; + } + +} diff --git a/doc/TRO_Graph_UH01-UH05.svg b/doc/TRO_Graph_UH01-UH05.svg new file mode 100644 index 0000000..68fbb0f --- /dev/null +++ b/doc/TRO_Graph_UH01-UH05.svg @@ -0,0 +1,4579 @@ + + + + + + +TRO_Topologie + +TRO-Topologie HundM_Fortna (UH01-UH05) + +cluster_UH01 + +UH01  (=A01+UH01-KF00) + + +cluster_UH02 + +UH02  (=A01+UH02-KF00) + + +cluster_UH03 + +UH03  (=A01+UH03-KF00) + + +cluster_UH04 + +UH04  (=A01+UH04-KF00) + + +cluster_UH05 + +UH05  (=A01+UH05-KF00) + + + +UH01.TRO100 + +TRO100 +[1Sep] +TRO 100 (1Sep) + + + +UH01.TRO101_IN + +TRO101_IN +[1Sep] +TRO 101_IN(1Sep) + + + +UH01.TRO100->UH01.TRO101_IN + + +JA0101_1 + + + +UH01.TRO101 + + + + +TRO101 +[EmptyCarrBuffer] +TRO101 (Empty Buffer rechts) + + + +UH01.TRO112 + +TRO112 +[1Sep1Swi] +TRO 112 (1Sep1Swi) + + + +UH01.TRO101->UH01.TRO112 + + +JA0102_2 + + + +UH01.TRO101_IN->UH01.TRO101 + + +JamBuffer101 + + + +UH01.TRO102_IN + +TRO102_IN +[1Sep] +TRO 102_IN(1Sep) + + + +UH01.TRO101_IN->UH01.TRO102_IN + + +JA0101_2 + + + +UH01.TRO102 + + + + +TRO102 +[EmptyCarrBuffer] +TRO102 (Empty Buffer links) + + + +UH01.TRO107 + +TRO107 +[1Sep1Swi] +TRO 107(1Sep1Swi) + + + +UH01.TRO102->UH01.TRO107 + + +JA0102_1 + + + +UH01.TRO102_IN->UH01.TRO102 + + +JamBuffer102 + + + +UH01.TRO103 + +TRO103 +[1Sep] +TRO 103 (1Sep) + + + +UH01.TRO104 + +TRO104 +[1Sep] +TRO 104 (1Sep)+Scanner + + + +UH01.TRO103->UH01.TRO104 + + +JA0104_1 + + + +UH01.fbLoadingBoom1 + +fbLoadingBoom1 +[LoadingBoom_INBOUND] +LoadingBoom 1 + + + +UH01.TRO104->UH01.fbLoadingBoom1 + + +JA0104_2 + + + +UH01.TRO105 + +TRO105 +[1Sep_SSCC] +TRO 105 (1Sep)+Scanner + + + +UH01.TRO106 + +TRO106 +[1Sep] +TRO 106 (1Sep) + + + +UH01.TRO105->UH01.TRO106 + + +JA0106_2 + + + +UH01.TRO106->UH01.TRO112 + + +JA0102_2 + + + +UH01.TRO107->UH01.TRO103 + + +JA0103_1 + + + +UH01.TRO107->UH01.TRO112 + + +JA0102_2 Dir2 + + + +UH01.TRO108 + +TRO108 +[1Sep] +TRO 108 (1Sep) + + + +UH01.TRO109 + +TRO109 +[1Sep] +TRO 109 (1Sep)+Scanner + + + +UH01.TRO108->UH01.TRO109 + + +JA0108_1 + + + +UH01.fbLoadingBoom2 + +fbLoadingBoom2 +[LoadingBoom_INBOUND] +LoadingBoom 2 + + + +UH01.TRO109->UH01.fbLoadingBoom2 + + +JA0108_2 + + + +UH01.TRO110 + +TRO110 +[1Sep_SSCC] +TRO 110 (1Sep)+Scanner + + + +UH01.TRO111 + +TRO111 +[1Sep] +TRO 111 (1Sep) + + + +UH01.TRO110->UH01.TRO111 + + +JA0110_2 + + + +UH01.TRO113 + +TRO113 +[1Sep] +TRO 113 (1Sep)+Scanner + + + +UH01.TRO111->UH01.TRO113 + + +JA0102_3 + + + +UH01.TRO112->UH01.TRO108 + + +JA0107_1 + + + +UH01.TRO112->UH01.TRO113 + + +JA0102_3 Dir2 + + + +UH01.TRO114 + +TRO114 +[1Sep1Swi] +TRO 114 (1Sep1Switch)+Scanner + + + +UH01.TRO113->UH01.TRO114 + + +JA0102_4 + + + +UH01.TRO116 + +TRO116 +[1Sep] +TRO 116 (1Sep) + + + +UH01.TRO114->UH01.TRO116 + + +JA0102_5 Dir2 + + + +UH01.TRO115 + +TRO115 +[Vario] +TRO 115 (Vario) + + + +UH01.TRO120 + +TRO120 +[Vario] +TRO 120 (Vario) + + + +UH01.TRO115->UH01.TRO120 + + +JA4103_1 Finger + + + +UH01.TRO117 + +TRO117 +[1Sep] +TRO 117 (1Sep) + Scanner + + + +UH01.TRO116->UH01.TRO117 + + +JA0102_6 + + + +UH01.TRO117->UH01.TRO107 + + +JA0102_1 + + + +UH01.TRO121 + +TRO121 +[Vario] +TRO 121(Vario) + + + +UH01.TRO122 + +TRO122 +[1Sep] +TRO 122 (1Sep) + + + +UH01.TRO121->UH01.TRO122 + + +JA4503_2 Finger + + + +UH01.TRO123 + +TRO123 +[Vario] +TRO 123 (Vario) + + + +UH01.TRO122->UH01.TRO123 + + +JA4502_1 + + + +UH01.TRO124 + +TRO124 +[1Sep1Swi] +TRO 124 (1Sep1Switch) + + + +UH01.TRO123->UH01.TRO124 + + +JA4502_2 Finger + + + +UH01.TRO125 + +TRO125 +[1Sep] +TRO 125 (1Sep) + + + +UH01.TRO124->UH01.TRO125 + + +JA4204_2 + + + +UH01.TRO127 + +TRO127 +[Vario] +TRO 127 (Vario) + + + +UH01.TRO124->UH01.TRO127 + + +JA4501_1 Dir2 + + + +UH01.TRO126 + +TRO126 +[Vario] +TRO 126 (Vario) + + + +UH01.TRO125->UH01.TRO126 + + +JA4203_1 + + + +UH01.TRO128 + +TRO128 +[Vario] +TRO 128 (Vario) + + + +UH01.TRO127->UH01.TRO128 + + +JA4501_2 Finger + + + +UH01.TRO128->UH01.TRO100 + + +JA0100_1 Finger + + + +UH01.TRO129 + +TRO129 +[1Sep] +TRO 129 (1Sep) + + + +UH01.TRO130 + +TRO130 +[1Sep] +TRO 130 (1Sep) + + + +UH01.TRO129->UH01.TRO130 + + +JA4204_1 + + + +UH01.TRO130->UH01.TRO127 + + +JA4501_1 + + + +UH01.TRO131 + +TRO131 +[Vario] +TRO 131 (Vario) + + + +UH01.TRO133 + +TRO133 +[Vario] +TRO 133 (Vario) + + + +UH01.TRO133->UH01.TRO129 + + +JA4302_2 Finger + + + +UH01.TRO134 + +TRO134 +[Vario] +TRO 134 (Vario) + + + +UH01.TRO134->UH01.TRO131 + + +JA4403_1 Finger + + + +UH01.fbLoadingBoom1->UH01.TRO105 + + +JA0104_3 + + + +UH01.fbLoadingBoom2->UH01.TRO110 + + +JA0108_3 + + + +UH01.EXTERN_IN + +EXTERN +(Zulauf) + + + +UH01.EXTERN_IN->UH01.TRO115 + + +JA4104_1 + + + +UH01.EXTERN_IN->UH01.TRO121 + + +JA4503_1 + + + +UH01.EXTERN_IN->UH01.TRO133 + + +JA4302_1 + + + +UH01.EXTERN_IN->UH01.TRO134 + + +JA4402_1 + + + +UH02.TRO200 + +TRO200 +[Vario] +TRO 200 (Vario) + + + +UH02.TRO201 + +TRO201 +[1Sep] +TRO 201 (1Sep) + + + +UH02.TRO200->UH02.TRO201 + + +JA1109_2 Finger + + + +UH02.TRO202 + +TRO202 +[1Sep1Swi] +TRO 202 (1Sep1Switch)+Scanner(BX2103) + + + +UH02.TRO201->UH02.TRO202 + + +JA1102_1 + + + +UH02.TRO211 + +TRO211 +[PinStore_Auto] +Aufruf: TRO211 + + + +UH02.TRO202->UH02.TRO211 + + +JA1101_1 Dir2 + + + +UH02.TRO214 + +TRO214 +[PinStore_Auto] +Aufruf: TRO214 + + + +UH02.TRO202->UH02.TRO214 + + +JA1102_2 + + + +UH02.TRO203 + +TRO203 +[1Sep1Swi] +TRO 203 (1Sep1Switch) + Scanner (BX2111) + + + +UH02.TRO204 + +TRO204 +[1Sep1Swi] +TRO 204(1Sep1Switch) + Scanner(BX2112) + + + +UH02.TRO203->UH02.TRO204 + + +JA1103_2 Dir2 + + + +UH02.TRO209 + +TRO209 +[Vario] +TRO 209 (Vario) + + + +UH02.TRO203->UH02.TRO209 + + +JA1105_1 + + + +UH02.TRO207 + +TRO207 +[1Sep] +TRO 207(1Sep) + + + +UH02.TRO204->UH02.TRO207 + + +JA1104_3 Dir2 + + + +UH02.TRO212 + +TRO212 +[Vario] +TRO 212 (Vario) + + + +UH02.TRO204->UH02.TRO212 + + +JA1106_1 + + + +UH02.TRO205 + +TRO205 +[1Sep1Swi] +TRO 205 (1Sep1Switch) + Scanner(BX2114) + + + +UH02.TRO206 + +TRO206 +[1Sep1Swi] +TRO 206 (1Sep1Switch)+Scanner(BX2113) + + + +UH02.TRO205->UH02.TRO206 + + +JA1104_2 + + + +UH02.TRO218 + +TRO218 +[Vario] +TRO 218 (Vario) + + + +UH02.TRO205->UH02.TRO218 + + +JA1108_1 Dir2 + + + +UH02.TRO206->UH02.TRO207 + + +JA1104_3 + + + +UH02.TRO215 + +TRO215 +[Vario] +TRO 215 (Vario) + + + +UH02.TRO206->UH02.TRO215 + + +JA1107_1 Dir2 + + + +UH02.EXTERN_OUT + +EXTERN +(Ablauf) + + + +UH02.TRO207->UH02.EXTERN_OUT + + +IO_Device_UH02_TO_UH01.stCARRIER_INFO + + + +UH02.TRO208 + +TRO208 +[PinStore_Auto] +Aufruf: TRO208 + + + +UH02.TRO208->UH02.TRO203 + + +JA1103_1 + + + +UH02.TRO210 + +TRO210 +[1Sep] +TRO 210 (1Sep) + + + +UH02.TRO209->UH02.TRO210 + + +JA1105_2 Finger + + + +UH02.TRO210->UH02.TRO208 + + +JA1101_2 + + + +UH02.TRO211->UH02.TRO204 + + +JA1103_2 + + + +UH02.TRO211->UH02.TRO208 + + +JA1101_2 Bypass + + + +UH02.TRO213 + +TRO213 +[1Sep] +TRO 213 (1Sep) + + + +UH02.TRO212->UH02.TRO213 + + +JA1106_2 Finger + + + +UH02.TRO213->UH02.TRO211 + + +JA1101_1 + + + +UH02.TRO214->UH02.TRO206 + + +JA1104_2 + + + +UH02.TRO217 + +TRO217 +[PinStore_Auto] +Aufruf: TRO217 + + + +UH02.TRO214->UH02.TRO217 + + +JA1102_3 Bypass + + + +UH02.TRO216 + +TRO216 +[1Sep] +TRO 216 (1Sep) + + + +UH02.TRO215->UH02.TRO216 + + +JA1107_2 Finger + + + +UH02.TRO216->UH02.TRO214 + + +JA1102_2 + + + +UH02.TRO217->UH02.TRO205 + + +JA1104_1 + + + +UH02.TRO219 + +TRO219 +[1Sep] +TRO 219(1Sep) + + + +UH02.TRO218->UH02.TRO219 + + +JA1108_2 Finger + + + +UH02.TRO219->UH02.TRO217 + + +JA1102_3 + + + +UH02.TRO220 + +TRO220 +[Vario] +TRO 220 (Vario) + + + +UH02.TRO221 + +TRO221 +[1Sep] +TRO 221 (1Sep) + + + +UH02.TRO220->UH02.TRO221 + + +JA1209_2 Finger + + + +UH02.TRO222 + +TRO222 +[1Sep1Swi] +TRO 222 (1Sep1Switch)+Scanner(BX2121) + + + +UH02.TRO221->UH02.TRO222 + + +JA1202_1 + + + +UH02.TRO231 + +TRO231 +[PinStore_Auto] +Aufruf: TRO231 + + + +UH02.TRO222->UH02.TRO231 + + +JA1201_1 Dir2 + + + +UH02.TRO234 + +TRO234 +[PinStore_Auto] +Aufruf: TRO234 + + + +UH02.TRO222->UH02.TRO234 + + +JA1202_2 + + + +UH02.TRO223 + +TRO223 +[1Sep1Swi] +TRO 223 (1Sep1Switch)+Scanner(BX2126) + + + +UH02.TRO224 + +TRO224 +[1Sep1Swi] +TRO 224 (1Sep1Switch)+Scanner(BX2127) + + + +UH02.TRO223->UH02.TRO224 + + +JA1203_2 Dir2 + + + +UH02.TRO229 + +TRO229 +[Vario] +TRO 229 (Vario) + + + +UH02.TRO223->UH02.TRO229 + + +JA1205_1 + + + +UH02.TRO227 + +TRO227 +[1Sep] +TRO 227 (1Sep) + + + +UH02.TRO224->UH02.TRO227 + + +JA1204_3 Dir2 + + + +UH02.TRO232 + +TRO232 +[Vario] +TRO 232 (Vario) + + + +UH02.TRO224->UH02.TRO232 + + +JA1206_1 + + + +UH02.TRO225 + +TRO225 +[1Sep1Swi] +TRO 225(1Sep1Switch)+Scanner(BX2129) + + + +UH02.TRO226 + +TRO226 +[1Sep1Swi] +TRO 226 (1Sep1Switch)+Scanner(BX2128) + + + +UH02.TRO225->UH02.TRO226 + + +JA1204_2 + + + +UH02.TRO238 + +TRO238 +[Vario] +TRO 238 (Vario) + + + +UH02.TRO225->UH02.TRO238 + + +JA1208_1 Dir2 + + + +UH02.TRO226->UH02.TRO227 + + +JA1204_3 + + + +UH02.TRO235 + +TRO235 +[Vario] +TRO 235 (Vario) + + + +UH02.TRO226->UH02.TRO235 + + +JA1207_1 Dir2 + + + +UH02.TRO227->UH02.EXTERN_OUT + + +IO_Device_UH02_TO_UH01.stCARRIER_INFO_1 + + + +UH02.TRO228 + +TRO228 +[PinStore_Auto] +Aufruf: TRO228 + + + +UH02.TRO228->UH02.TRO223 + + +JA1203_1 + + + +UH02.TRO230 + +TRO230 +[1Sep] +TRO 230 (1Sep) + + + +UH02.TRO229->UH02.TRO230 + + +JA1205_2 Finger + + + +UH02.TRO230->UH02.TRO228 + + +JA1201_2 + + + +UH02.TRO231->UH02.TRO224 + + +JA1203_2 + + + +UH02.TRO231->UH02.TRO228 + + +JA1201_2 Bypass + + + +UH02.TRO233 + +TRO233 +[1Sep] +TRO 233 (1Sep) + + + +UH02.TRO232->UH02.TRO233 + + +JA1206_2 Finger + + + +UH02.TRO233->UH02.TRO231 + + +JA1201_1 + + + +UH02.TRO234->UH02.TRO226 + + +JA1204_2 + + + +UH02.TRO237 + +TRO237 +[PinStore_Auto] +Aufruf: TRO237 + + + +UH02.TRO234->UH02.TRO237 + + +JA1202_3 Bypass + + + +UH02.TRO236 + +TRO236 +[1Sep] +TRO 236 (1Sep) + + + +UH02.TRO235->UH02.TRO236 + + +JA1207_2 Finger + + + +UH02.TRO236->UH02.TRO234 + + +JA1202_2 + + + +UH02.TRO237->UH02.TRO225 + + +JA1204_1 + + + +UH02.TRO239 + +TRO239 +[1Sep] +TRO 239 (1Sep) + + + +UH02.TRO238->UH02.TRO239 + + +JA1208_2 Finger + + + +UH02.TRO239->UH02.TRO237 + + +JA1202_3 + + + +UH02.TRO240 + +TRO240 +[Vario] +TRO 240 (Vario) + + + +UH02.TRO241 + +TRO241 +[1Sep] +TRO 241(1Sep) + + + +UH02.TRO240->UH02.TRO241 + + +JA1309_2 Finger + + + +UH02.TRO242 + +TRO242 +[1Sep1Swi] +TRO 242 (1Sep1Switch)+Scanner(BX2130) + + + +UH02.TRO241->UH02.TRO242 + + +JA1304_1 + + + +UH02.TRO251 + +TRO251 +[PinStore_Auto] +Aufruf: TRO251 + + + +UH02.TRO242->UH02.TRO251 + + +JA1303_1 + + + +UH02.TRO254 + +TRO254 +[PinStore_Auto] +Aufruf: TRO254 + + + +UH02.TRO242->UH02.TRO254 + + +JA1304_2 Dir2 + + + +UH02.TRO243 + +TRO243 +[1Sep1Swi] +TRO 243 (1Sep1Switch)+Scanner(BX3137) + + + +UH02.TRO244 + +TRO244 +[1Sep1Swi] +TRO 244 (1Sep1Switch)+Scanner(BX2136) + + + +UH02.TRO243->UH02.TRO244 + + +JA1301_2 + + + +UH02.TRO249 + +TRO249 +[Vario] +TRO 249 (Vario) + + + +UH02.TRO243->UH02.TRO249 + + +JA1305_1 Dir2 + + + +UH02.TRO252 + +TRO252 +[Vario] +TRO 252 (Vario) + + + +UH02.TRO244->UH02.TRO252 + + +JA1306_1 Dir2 + + + +UH02.TRO244->UH02.EXTERN_OUT + + +JA1302_3 + + + +UH02.TRO245 + +TRO245 +[1Sep1Swi] +TRO 245 (1Sep1Switch)+Scanner(BX2138) + + + +UH02.TRO246 + +TRO246 +[1Sep1Swi] +TRO 246 (1Sep1Switch)+Scanner(BX2137) + + + +UH02.TRO245->UH02.TRO246 + + +JA1302_2 Dir2 + + + +UH02.TRO258 + +TRO258 +[Vario] +TRO 258 (Vario) + + + +UH02.TRO245->UH02.TRO258 + + +JA1308_1 + + + +UH02.TRO255 + +TRO255 +[Vario] +TRO 255 (Vario) + + + +UH02.TRO246->UH02.TRO255 + + +JA1307_1 + + + +UH02.TRO246->UH02.EXTERN_OUT + + +JA1302_3 + + + +UH02.TRO247 + +TRO247 +[1Sep] +TRO 247(1Sep) + + + +UH02.TRO247->UH02.EXTERN_OUT + + +IO_Device_UH02_TO_UH01.stCARRIER_INFO_2 + + + +UH02.TRO248 + +TRO248 +[PinStore_Auto] +Aufruf: TRO248 + + + +UH02.TRO248->UH02.TRO243 + + +JA1301_1 + + + +UH02.TRO250 + +TRO250 +[1Sep] +TRO 250 (1Sep) + + + +UH02.TRO249->UH02.TRO250 + + +JA1305_2 Finger + + + +UH02.TRO250->UH02.TRO248 + + +JA1303_2 + + + +UH02.TRO251->UH02.TRO244 + + +JA1301_2 + + + +UH02.TRO251->UH02.TRO248 + + +JA1303_2 Bypass + + + +UH02.TRO253 + +TRO253 +[1Sep] +TRO 253 (1Sep) + + + +UH02.TRO252->UH02.TRO253 + + +JA1306_2 Finger + + + +UH02.TRO253->UH02.TRO251 + + +JA1303_1 + + + +UH02.TRO254->UH02.TRO246 + + +JA1302_2 + + + +UH02.TRO257 + +TRO257 +[PinStore_Auto] +Aufruf: TRO257 + + + +UH02.TRO254->UH02.TRO257 + + +JA1304_3 Bypass + + + +UH02.TRO256 + +TRO256 +[1Sep] +TRO 256 (1Sep) + + + +UH02.TRO255->UH02.TRO256 + + +JA1307_2 Finger + + + +UH02.TRO256->UH02.TRO254 + + +JA1304_2 + + + +UH02.TRO257->UH02.TRO245 + + +JA1302_1 + + + +UH02.TRO259 + +TRO259 +[1Sep] +TRO 259 (1Sep) + + + +UH02.TRO258->UH02.TRO259 + + +JA1308_2 Finger + + + +UH02.TRO259->UH02.TRO257 + + +JA1304_3 + + + +UH02.TRO260 + +TRO260 +[Vario] +TRO 260 (Vario) + Scanner (BX2115) + + + +UH02.TRO261 + +TRO261 +[1Sep] +TRO 261 (1Sep) + + + +UH02.TRO260->UH02.TRO261 + + +JA1601_2 Finger + + + +UH02.TRO274 + +TRO274 +[1Sep] +TRO 274 (1Sep) + + + +UH02.TRO261->UH02.TRO274 + + +JA1110_2 + + + +UH02.TRO262 + +TRO262 +[Vario] +TRO 262 (Vario) + Scanner (BX2109) + + + +UH02.TRO263 + +TRO263 +[1Sep] +TRO 263 (1Sep) + + + +UH02.TRO262->UH02.TRO263 + + +JA1501_2 Finger + + + +UH02.TRO266 + +TRO266 +[1Sep] +TRO 266(1Sep) + + + +UH02.TRO263->UH02.TRO266 + + +JA1110_3 + + + +UH02.TRO264 + +TRO264 +[Vario] +TRO 264 (Vario) + Scanner (BX2108) + + + +UH02.TRO265 + +TRO265 +[1Sep] +TRO 265 (1Sep) + + + +UH02.TRO264->UH02.TRO265 + + +JA1401_2 Finger + + + +UH02.TRO267 + +TRO267 +[1Sep2Swi] +TRO 267 (1Sep2Switch)+Scanner(BX2100) + + + +UH02.TRO265->UH02.TRO267 + + +JA1110_4 + + + +UH02.TRO266->UH02.TRO267 + + +JA1110_4 + + + +UH02.TRO275 + +TRO275 +[1Sep] +TRO 275 (1Sep) + + + +UH02.TRO267->UH02.TRO275 + + +JA1110_5 Dir3 + + + +UH02.TRO268 + +TRO268 +[1Sep2Swi] +TRO 268 (1Sep2Switch)+Scanner(BX2101) + + + +UH02.TRO269 + +TRO269 +[1Sep] +TRO 269 (1Sep)+Scanner (BX2102) + + + +UH02.TRO268->UH02.TRO269 + + +JA1110_1 Dir3 + + + +UH02.TRO269->UH02.TRO274 + + +JA1110_2 + + + +UH02.TRO270 + +TRO270 +[Vario] +TRO 270 (Vario) + + + +UH02.TRO272 + +TRO272 +[Vario] +TRO 272 (Vario) + + + +UH02.TRO274->UH02.TRO266 + + +JA1110_3 + + + +UH02.TRO275->UH02.TRO268 + + +JA1110_6 + + + +UH02.EXTERN_IN + +EXTERN +(Zulauf) + + + +UH02.EXTERN_IN->UH02.TRO200 + + +JA1109_1 + + + +UH02.EXTERN_IN->UH02.TRO208 + + +Storage1.1.1 + + + +UH02.EXTERN_IN->UH02.TRO211 + + +Storage1.1.2 + + + +UH02.EXTERN_IN->UH02.TRO214 + + +Storage1.1.3 + + + +UH02.EXTERN_IN->UH02.TRO217 + + +Storage1.1.4 + + + +UH02.EXTERN_IN->UH02.TRO220 + + +JA1209_1 + + + +UH02.EXTERN_IN->UH02.TRO228 + + +Storage1.2.1 + + + +UH02.EXTERN_IN->UH02.TRO231 + + +Storage1.2.2 + + + +UH02.EXTERN_IN->UH02.TRO234 + + +Storage1.2.3 + + + +UH02.EXTERN_IN->UH02.TRO237 + + +Storage1.2.4 + + + +UH02.EXTERN_IN->UH02.TRO240 + + +JA1309_1 + + + +UH02.EXTERN_IN->UH02.TRO248 + + +Storage1.3.1 + + + +UH02.EXTERN_IN->UH02.TRO251 + + +Storage1.3.2 + + + +UH02.EXTERN_IN->UH02.TRO254 + + +Storage1.3.3 + + + +UH02.EXTERN_IN->UH02.TRO257 + + +Storage1.3.4 + + + +UH02.EXTERN_IN->UH02.TRO260 + + +JA1601_1 + + + +UH02.EXTERN_IN->UH02.TRO262 + + +JA1501_1 + + + +UH02.EXTERN_IN->UH02.TRO264 + + +JA1401_1 + + + +UH02.EXTERN_IN->UH02.TRO270 + + +JA4701_1 + + + +UH02.EXTERN_IN->UH02.TRO272 + + +JA1801_1 + + + +UH03.TRO300 + +TRO300 +[Vario] +TRO 300 (Vario) + + + +UH03.TRO302 + +TRO302 +[Vario] +TRO 302 (Vario) + + + +UH03.TRO300->UH03.TRO302 + + +JA4101_1 Finger + + + +UH03.TRO301 + +TRO301 +[1Sep] +TRO 301(1Sep) + + + +UH03.TRO301->UH03.TRO302 + + +JA4101_1 + + + +UH03.TRO311 + +TRO311 +[1Sep] +TRO 311 (1Sep)+Scanner(BX3101) + + + +UH03.TRO302->UH03.TRO311 + + +JA4101_2 Finger + + + +UH03.TRO303 + +TRO303 +[Vario] +TRO 303 (Vario) + + + +UH03.TRO305 + +TRO305 +[Vario] +TRO 305 (Vario) + + + +UH03.TRO303->UH03.TRO305 + + +JA4201_1 Finger + + + +UH03.TRO304 + +TRO304 +[1Sep] +TRO 304(1Sep) + + + +UH03.TRO304->UH03.TRO305 + + +JA4201_1 + + + +UH03.TRO312 + +TRO312 +[1Sep] +TRO 312 (1Sep)+Scanner(BX3100) + + + +UH03.TRO305->UH03.TRO312 + + +JA4201_2 Finger + + + +UH03.TRO306 + +TRO306 +[Vario] +TRO 306 (Vario) + + + +UH03.TRO307 + +TRO307 +[Vario] +TRO 307 (Vario) + + + +UH03.TRO308 + +TRO308 +[Vario] +TRO 308 (Vario) + + + +UH03.TRO309 + +TRO309 +[1Sep] +TRO 309 (1Sep) + + + +UH03.TRO308->UH03.TRO309 + + +JA2111_2 Finger + + + +UH03.TRO386 + +TRO386 +[1Sep] +TRO 386 (1Sep) - kam später dazu + + + +UH03.TRO309->UH03.TRO386 + + +JA2110_5 + + + +UH03.TRO310 + +TRO310 +[1Sep] +TRO 310 (1Sep)+Scanner (BX3102) + + + +UH03.TRO313 + +TRO313 +[1Sep1Swi] +TRO 313 (1Sep1Switch)+Scanner(BX3103) + + + +UH03.TRO310->UH03.TRO313 + + +JA2110_2 + + + +UH03.TRO311->UH03.TRO313 + + +JA2110_2 + + + +UH03.TRO312->UH03.TRO313 + + +JA2110_2 + + + +UH03.TRO314 + +TRO314 +[1Sep1Swi] +TRO 314 (1Sep1Switch)+Scanner(BX3104) + + + +UH03.TRO313->UH03.TRO314 + + +JA2110_3 Dir2 + + + +UH03.TRO316 + +TRO316 +[1Sep] +TRO 316 (1Sep) + + + +UH03.TRO313->UH03.TRO316 + + +JA2112_1 + + + +UH03.TRO315 + +TRO315 +[1Sep] +TRO 315 (1Sep) + + + +UH03.TRO314->UH03.TRO315 + + +JA2110_4 Dir2 + + + +UH03.TRO339 + +TRO339 +[1Sep1Swi] +TRO 339 (1Sep1Switch)+Scanner(BX3120) + + + +UH03.TRO314->UH03.TRO339 + + +JA2202_1 + + + +UH03.TRO317 + +TRO317 +[1Sep1Swi] +TRO 317 (1Sep1Switch)+Scanner(BX3105) + + + +UH03.TRO315->UH03.TRO317 + + +JA2102_1 + + + +UH03.TRO361 + +TRO361 +[1Sep1Swi] +TRO 361 (1Sep1Switch)+Scanner(BX3131) + + + +UH03.TRO316->UH03.TRO361 + + +JA2304_1 + + + +UH03.TRO318 + +TRO318 +[1Sep1Swi] +TRO 318 (1Sep1Switch) + Scanner(BX3106) + + + +UH03.TRO317->UH03.TRO318 + + +JA2102_2 + + + +UH03.EXTERN_OUT + +EXTERN +(Ablauf) + + + +UH03.TRO317->UH03.EXTERN_OUT + + +IO_Device_UH03_TO_UH01.stCarrierL2toL1 + + + +UH03.TRO330 + +TRO330 +[PinStore_Auto] +Aufruf: TRO330 + + + +UH03.TRO318->UH03.TRO330 + + +JA2101_1 Dir2 + + + +UH03.TRO333 + +TRO333 +[PinStore_Auto] +Aufruf: TRO333 + + + +UH03.TRO318->UH03.TRO333 + + +JA2102_3 + + + +UH03.TRO319 + +TRO319 +[1Sep1Swi] +TRO 319 (1Sep1Switch) + Scanner (BX3111) + + + +UH03.TRO320 + +TRO320 +[1Sep1Swi] +TRO 320 (1Sep1Switch) + Scanner(BX3112) + + + +UH03.TRO319->UH03.TRO320 + + +JA2103_2 Dir2 + + + +UH03.TRO328 + +TRO328 +[Vario] +TRO 328 (Vario) + + + +UH03.TRO319->UH03.TRO328 + + +JA2105_1 + + + +UH03.TRO323 + +TRO323 +[1Sep] +TRO 323 (1Sep) + + + +UH03.TRO320->UH03.TRO323 + + +JA2104_3 Dir2 + + + +UH03.TRO331 + +TRO331 +[Vario] +TRO 331 (Vario) + + + +UH03.TRO320->UH03.TRO331 + + +JA2106_1 + + + +UH03.TRO321 + +TRO321 +[1Sep1Swi] +TRO 321 (1Sep1Switch) + Scanner(BX3114) + + + +UH03.TRO322 + +TRO322 +[1Sep1Swi] +TRO 322 (1Sep1Switch)+Scanner(BX3113) + + + +UH03.TRO321->UH03.TRO322 + + +JA2104_2 + + + +UH03.TRO337 + +TRO337 +[Vario] +TRO 337 (Vario) + + + +UH03.TRO321->UH03.TRO337 + + +JA2108_1 Dir2 + + + +UH03.TRO322->UH03.TRO323 + + +JA2104_3 + + + +UH03.TRO334 + +TRO334 +[Vario] +TRO 334 (Vario) + + + +UH03.TRO322->UH03.TRO334 + + +JA2107_1 Dir2 + + + +UH03.TRO326 + +TRO326 +[1Sep] +TRO 326 (1Sep) + + + +UH03.TRO323->UH03.TRO326 + + +JA2104_4 + + + +UH03.TRO324 + +TRO324 +[Vario] +TRO 324 (Vario) + + + +UH03.TRO325 + +TRO325 +[1Sep] +TRO 325 (1Sep) + + + +UH03.TRO324->UH03.TRO325 + + +JA2109_2 Finger + + + +UH03.TRO325->UH03.TRO326 + + +JA2104_4 + + + +UH03.TRO326->UH03.EXTERN_OUT + + +IO_Device_UH03_TO_UH01.stCARRIER_INFO + + + +UH03.TRO327 + +TRO327 +[PinStore_Auto] +Aufruf: TRO327 + + + +UH03.TRO327->UH03.TRO319 + + +JA2103_1 + + + +UH03.TRO329 + +TRO329 +[1Sep] +TRO 329 (1Sep) + + + +UH03.TRO328->UH03.TRO329 + + +JA2105_2 Finger + + + +UH03.TRO329->UH03.TRO327 + + +JA2101_2 + + + +UH03.TRO330->UH03.TRO320 + + +JA2103_2 + + + +UH03.TRO330->UH03.TRO327 + + +JA2101_2 Bypass + + + +UH03.TRO332 + +TRO332 +[1Sep] +TRO 332 (1Sep) + + + +UH03.TRO331->UH03.TRO332 + + +JA2106_2 Finger + + + +UH03.TRO332->UH03.TRO330 + + +JA2101_1 + + + +UH03.TRO333->UH03.TRO322 + + +JA2104_2 + + + +UH03.TRO336 + +TRO336 +[PinStore_Auto] +Aufruf: TRO336 + + + +UH03.TRO333->UH03.TRO336 + + +JA2102_4 Bypass + + + +UH03.TRO335 + +TRO335 +[1Sep] +TRO 335 (1Sep) + + + +UH03.TRO334->UH03.TRO335 + + +JA2107_2 Finger + + + +UH03.TRO335->UH03.TRO333 + + +JA2102_3 + + + +UH03.TRO336->UH03.TRO321 + + +JA2104_1 + + + +UH03.TRO336->UH03.EXTERN_OUT + + +JA2102_5 + + + +UH03.TRO338 + +TRO338 +[1Sep] +TRO 338 (1Sep) + + + +UH03.TRO337->UH03.TRO338 + + +JA2108_2 Finger + + + +UH03.TRO338->UH03.TRO336 + + +JA2102_4 + + + +UH03.TRO340 + +TRO340 +[1Sep1Swi] +TRO 340 (1Sep1Switch)+Scanner(BX3121) + + + +UH03.TRO339->UH03.TRO340 + + +JA2202_2 + + + +UH03.TRO339->UH03.EXTERN_OUT + + +IO_Device_UH03_TO_UH01.stCarrierL2toL1_2 + + + +UH03.TRO352 + +TRO352 +[PinStore_Auto] +Aufruf: TRO352 + + + +UH03.TRO340->UH03.TRO352 + + +JA2201_1 Dir2 + + + +UH03.TRO355 + +TRO355 +[PinStore_Auto] +Aufruf: TRO355 + + + +UH03.TRO340->UH03.TRO355 + + +JA2202_3 + + + +UH03.TRO341 + +TRO341 +[1Sep1Swi] +TRO 341 (1Sep1Switch)+Scanner(BX3126) + + + +UH03.TRO342 + +TRO342 +[1Sep1Swi] +TRO 342 (1Sep1Switch)+Scanner(BX3127) + + + +UH03.TRO341->UH03.TRO342 + + +JA2203_2 Dir2 + + + +UH03.TRO350 + +TRO350 +[Vario] +TRO 350 (Vario) + + + +UH03.TRO341->UH03.TRO350 + + +JA2205_1 + + + +UH03.TRO345 + +TRO345 +[1Sep] +TRO 345 (1Sep) + + + +UH03.TRO342->UH03.TRO345 + + +JA2204_3 Dir2 + + + +UH03.TRO353 + +TRO353 +[Vario] +TRO 353 (Vario) + + + +UH03.TRO342->UH03.TRO353 + + +JA2206_1 + + + +UH03.TRO343 + +TRO343 +[1Sep1Swi] +TRO 343 (1Sep1Switch)+Scanner(BX3129) + + + +UH03.TRO344 + +TRO344 +[1Sep1Swi] +TRO 344 (1Sep1Switch)+Scanner(BX3128) + + + +UH03.TRO343->UH03.TRO344 + + +JA2204_2 + + + +UH03.TRO359 + +TRO359 +[Vario] +TRO 359 (Vario) + + + +UH03.TRO343->UH03.TRO359 + + +JA2208_1 Dir2 + + + +UH03.TRO344->UH03.TRO345 + + +JA2204_3 + + + +UH03.TRO356 + +TRO356 +[Vario] +TRO 356 (Vario) + + + +UH03.TRO344->UH03.TRO356 + + +JA2207_1 Dir2 + + + +UH03.TRO348 + +TRO348 +[1Sep] +TRO 348 (1Sep) + + + +UH03.TRO345->UH03.TRO348 + + +JA2204_4 + + + +UH03.TRO346 + +TRO346 +[Vario] +TRO 346 (Vario) + + + +UH03.TRO347 + +TRO347 +[1Sep] +TRO 347 (1Sep) + + + +UH03.TRO346->UH03.TRO347 + + +JA2209_2 Finger + + + +UH03.TRO347->UH03.TRO348 + + +JA2204_4 + + + +UH03.TRO348->UH03.EXTERN_OUT + + +IO_Device_UH03_TO_UH01.stCARRIER_INFO_1 + + + +UH03.TRO349 + +TRO349 +[PinStore_Auto] +Aufruf: TRO349 + + + +UH03.TRO349->UH03.TRO341 + + +JA2203_1 + + + +UH03.TRO351 + +TRO351 +[1Sep] +TRO 351 (1Sep) + + + +UH03.TRO350->UH03.TRO351 + + +JA2205_2 Finger + + + +UH03.TRO351->UH03.TRO349 + + +JA2201_2 + + + +UH03.TRO352->UH03.TRO342 + + +JA2203_2 + + + +UH03.TRO352->UH03.TRO349 + + +JA2201_2 Bypass + + + +UH03.TRO354 + +TRO354 +[1Sep] +TRO 354 (1Sep) + + + +UH03.TRO353->UH03.TRO354 + + +JA2206_2 Finger + + + +UH03.TRO354->UH03.TRO352 + + +JA2201_1 + + + +UH03.TRO355->UH03.TRO344 + + +JA2204_2 + + + +UH03.TRO358 + +TRO358 +[PinStore_Auto] +Aufruf: TRO358 + + + +UH03.TRO355->UH03.TRO358 + + +JA2202_4 Bypass + + + +UH03.TRO357 + +TRO357 +[1Sep] +TRO 357 (1Sep) + + + +UH03.TRO356->UH03.TRO357 + + +JA2207_2 Finger + + + +UH03.TRO357->UH03.TRO355 + + +JA2202_3 + + + +UH03.TRO358->UH03.TRO343 + + +JA2204_1 + + + +UH03.TRO358->UH03.EXTERN_OUT + + +JA2202_5 + + + +UH03.TRO360 + +TRO360 +[1Sep] +TRO 360 (1Sep) + + + +UH03.TRO359->UH03.TRO360 + + +JA2208_2 Finger + + + +UH03.TRO360->UH03.TRO358 + + +JA2202_4 + + + +UH03.TRO362 + +TRO362 +[1Sep1Swi] +TRO 362 (1Sep1Switch)+Scanner(BX3132) + + + +UH03.TRO361->UH03.TRO362 + + +JA2304_2 Dir2 + + + +UH03.TRO361->UH03.EXTERN_OUT + + +IO_Device_UH03_TO_UH01.stCarrierL2toL1_3 + + + +UH03.TRO374 + +TRO374 +[PinStore_Auto] +Aufruf: TRO374 + + + +UH03.TRO362->UH03.TRO374 + + +JA2303_1 + + + +UH03.TRO377 + +TRO377 +[PinStore_Auto] +Aufruf: TRO377 + + + +UH03.TRO362->UH03.TRO377 + + +JA2304_3 Dir2 + + + +UH03.TRO363 + +TRO363 +[1Sep1Swi] +TRO 363 (1Sep1Switch)+Scanner(BX3137) + + + +UH03.TRO364 + +TRO364 +[1Sep1Swi] +TRO 364 (1Sep1Switch)+Scanner(BX3138) + + + +UH03.TRO363->UH03.TRO364 + + +JA2301_2 + + + +UH03.TRO372 + +TRO372 +[Vario] +TRO 372 (Vario) + + + +UH03.TRO363->UH03.TRO372 + + +JA2305_1 Dir2 + + + +UH03.TRO367 + +TRO367 +[1Sep] +TRO 367 (1Sep) + + + +UH03.TRO364->UH03.TRO367 + + +JA2302_3 + + + +UH03.TRO375 + +TRO375 +[Vario] +TRO 375 (Vario) + + + +UH03.TRO364->UH03.TRO375 + + +JA2306_1 Dir2 + + + +UH03.TRO365 + +TRO365 +[1Sep1Swi] +TRO 365 (1Sep1Switch)+Scanner(BX3140) + + + +UH03.TRO366 + +TRO366 +[1Sep1Swi] +TRO 366 (1Sep1Switch)+Scanner(BX3139) + + + +UH03.TRO365->UH03.TRO366 + + +JA2302_2 Dir2 + + + +UH03.TRO381 + +TRO381 +[Vario] +TRO 381 (Vario) + + + +UH03.TRO365->UH03.TRO381 + + +JA2308_1 + + + +UH03.TRO366->UH03.TRO367 + + +JA2302_3 Dir2 + + + +UH03.TRO378 + +TRO378 +[Vario] +TRO 378 (Vario) + + + +UH03.TRO366->UH03.TRO378 + + +JA2307_1 + + + +UH03.TRO370 + +TRO370 +[1Sep] +TRO 370 (1Sep) + + + +UH03.TRO367->UH03.TRO370 + + +JA2302_4 + + + +UH03.TRO368 + +TRO368 +[Vario] +TRO 368 (Vario, from Lvl1) + + + +UH03.TRO369 + +TRO369 +[1Sep] +TRO 369 (1Sep) + + + +UH03.TRO368->UH03.TRO369 + + +JA2309_2 Finger + + + +UH03.TRO369->UH03.TRO370 + + +JA2302_4 + + + +UH03.TRO370->UH03.EXTERN_OUT + + +IO_Device_UH03_TO_UH01.stCARRIER_INFO_2 + + + +UH03.TRO371 + +TRO371 +[PinStore_Auto] +Aufruf: TRO371 + + + +UH03.TRO371->UH03.TRO363 + + +JA2301_1 + + + +UH03.TRO373 + +TRO373 +[1Sep] +TRO 373 (1Sep) + + + +UH03.TRO372->UH03.TRO373 + + +JA2305_2 Finger + + + +UH03.TRO373->UH03.TRO371 + + +JA2303_2 + + + +UH03.TRO374->UH03.TRO364 + + +JA2301_2 + + + +UH03.TRO374->UH03.TRO371 + + +JA2303_2 Bypass + + + +UH03.TRO376 + +TRO376 +[1Sep] +TRO 376 (1Sep) + + + +UH03.TRO375->UH03.TRO376 + + +JA2306_2 Finger + + + +UH03.TRO376->UH03.TRO374 + + +JA2303_1 + + + +UH03.TRO377->UH03.TRO366 + + +JA2302_2 + + + +UH03.TRO380 + +TRO380 +[PinStore_Auto] +Aufruf: TRO380 + + + +UH03.TRO377->UH03.TRO380 + + +JA2304_4 Bypass + + + +UH03.TRO379 + +TRO379 +[1Sep] +TRO 379 (1Sep) + + + +UH03.TRO378->UH03.TRO379 + + +JA2307_2 Finger + + + +UH03.TRO379->UH03.TRO377 + + +JA2304_3 + + + +UH03.TRO380->UH03.TRO365 + + +JA2302_1 + + + +UH03.TRO382 + +TRO382 +[1Sep] +TRO 382 (1Sep) + + + +UH03.TRO381->UH03.TRO382 + + +JA2308_2 Finger + + + +UH03.TRO382->UH03.TRO380 + + +JA2304_4 + + + +UH03.TRO386->UH03.TRO310 + + +JA2110_1 + + + +UH03.EXTERN_IN + +EXTERN +(Zulauf) + + + +UH03.EXTERN_IN->UH03.TRO300 + + +JA4102_1 + + + +UH03.EXTERN_IN->UH03.TRO301 + + +JA4102_2 + + + +UH03.EXTERN_IN->UH03.TRO303 + + +JA4202_1 + + + +UH03.EXTERN_IN->UH03.TRO304 + + +JA4202_2 + + + +UH03.EXTERN_IN->UH03.TRO306 + + +JA4301_1 + + + +UH03.EXTERN_IN->UH03.TRO307 + + +JA4401_1 + + + +UH03.EXTERN_IN->UH03.TRO308 + + +JA2111_1 + + + +UH03.EXTERN_IN->UH03.TRO324 + + +JA2109_1 + + + +UH03.EXTERN_IN->UH03.TRO327 + + +Storage2.1.1 + + + +UH03.EXTERN_IN->UH03.TRO330 + + +Storage2.1.2 + + + +UH03.EXTERN_IN->UH03.TRO333 + + +Storage2.1.3 + + + +UH03.EXTERN_IN->UH03.TRO336 + + +Storage2.1.4 + + + +UH03.EXTERN_IN->UH03.TRO346 + + +JA2209_1 + + + +UH03.EXTERN_IN->UH03.TRO349 + + +Storage2.2.1 + + + +UH03.EXTERN_IN->UH03.TRO352 + + +Storage2.2.2 + + + +UH03.EXTERN_IN->UH03.TRO355 + + +Storage2.2.3 + + + +UH03.EXTERN_IN->UH03.TRO358 + + +Storage2.2.4 + + + +UH03.EXTERN_IN->UH03.TRO368 + + +JA2309_1 + + + +UH03.EXTERN_IN->UH03.TRO371 + + +Storage2.3.1 + + + +UH03.EXTERN_IN->UH03.TRO374 + + +Storage2.3.2 + + + +UH03.EXTERN_IN->UH03.TRO377 + + +Storage2.3.3 + + + +UH03.EXTERN_IN->UH03.TRO380 + + +Storage2.3.4 + + + +UH04.TRO400 + +TRO400 +[Vario] +TRO 400 (Vario) + + + +UH04.TRO401 + +TRO401 +[Vario] +TRO 401 (Vario) + + + +UH04.TRO400->UH04.TRO401 + + +JA4001_1 Finger + + + +UH04.TRO402 + +TRO402 +[1Sep] +TRO 402 (1Sep) (Vor Brandschutztor) + + + +UH04.TRO401->UH04.TRO402 + + +JA4001_2 Finger + + + +UH04.TRO403 + +TRO403 +[Vario] +TRO 403 (Vario) + + + +UH04.TRO402->UH04.TRO403 + + +JA4002_1 + + + +UH04.TRO404 + +TRO404 +[1Sep] +TRO 404 (1Sep) + + + +UH04.TRO403->UH04.TRO404 + + +JA4002_2 Finger + + + +UH04.TRO424 + +TRO424 +[1Sep] +TRO 424 (1Sep) vor Behangskontrolle + + + +UH04.TRO404->UH04.TRO424 + + +JA4003_8 + + + +UH04.TRO405 + +TRO405 +[1Sep1Swi] +TRO 405 (1Sep1Switch) + Scanner (BX4100) + Behangskontrolle + + + +UH04.TRO406 + +TRO406 +[1Sep] +TRO 406 (1Sep) + Scanner (BX4101) + + + +UH04.TRO405->UH04.TRO406 + + +JA4003_2 Dir2 + + + +UH04.TRO407 + +TRO407 +[1Sep1Swi] +TRO 407 (1Sep1Switch) + Scanner (BX4102) + + + +UH04.TRO406->UH04.TRO407 + + +JA4003_3 + + + +UH04.TRO408 + +TRO408 +[Vario] +TRO 408 (Vario) + + + +UH04.TRO407->UH04.TRO408 + + +JA4004_1 + + + +UH04.TRO410 + +TRO410 +[1Sep1Swi] +TRO 410 (1Sep1Switch) + Scanner (BX4104) + + + +UH04.TRO407->UH04.TRO410 + + +JA4003_4 Dir2 + + + +UH04.TRO421 + +TRO421 +[Vario_workStation] +TRO 421 (Vario) + + + +UH04.TRO408->UH04.TRO421 + + +JA4004_2 Finger + + + +UH04.TRO409 + +TRO409 +[1Sep] +TRO 409 (1Sep) + + + +UH04.TRO409->UH04.TRO410 + + +JA4003_4 + + + +UH04.TRO411 + +TRO411 +[Vario] +TRO 411 (Vario) + + + +UH04.TRO410->UH04.TRO411 + + +JA4006_1 + + + +UH04.TRO413 + +TRO413 +[1Sep1Swi] +TRO 413(1Sep1Switch)+Scanner(BX4106) + + + +UH04.TRO410->UH04.TRO413 + + +JA4003_5 Dir2 + + + +UH04.TRO422 + +TRO422 +[Vario_workStation] +TRO 422 (Vario) + + + +UH04.TRO411->UH04.TRO422 + + +JA4006_2 Finger + + + +UH04.TRO412 + +TRO412 +[1Sep] +TRO 412 (1Sep) + + + +UH04.TRO412->UH04.TRO413 + + +JA4003_5 + + + +UH04.TRO414 + +TRO414 +[Vario] +TRO 414 (Vario) + + + +UH04.TRO413->UH04.TRO414 + + +JA4008_1 + + + +UH04.TRO416 + +TRO416 +[1Sep] +TRO 416 (1Sep) + Beladeprüfung + + + +UH04.TRO413->UH04.TRO416 + + +JA4003_6 Dir2 + + + +UH04.TRO423 + +TRO423 +[Vario_workStation] +TRO 423 (Vario) + + + +UH04.TRO414->UH04.TRO423 + + +JA4008_2 Finger + + + +UH04.TRO415 + +TRO415 +[1Sep] +TRO 415 (1Sep) + + + +UH04.TRO415->UH04.TRO416 + + +JA4003_6 + + + +UH04.TRO417 + +TRO417 +[1Sep] +TRO 417 (1Sep) + + + +UH04.TRO416->UH04.TRO417 + + +JA4003_7 + + + +UH04.TRO417->UH04.TRO424 + + +JA4003_8 + + + +UH04.TRO418 + +TRO418 +[Vario] +TRO 418 (Vario) + + + +UH04.TRO420 + +TRO420 +[Vario] +TRO 420 (Vario) + + + +UH04.TRO418->UH04.TRO420 + + +JA4011_1 Finger + + + +UH04.EXTERN_OUT + +EXTERN +(Ablauf) + + + +UH04.TRO421->UH04.EXTERN_OUT + + +JA4005_1 + + + +UH04.TRO422->UH04.TRO412 + + +JA4007_1 Finger + + + +UH04.TRO423->UH04.TRO415 + + +JA4009_1 Finger + + + +UH04.TRO424->UH04.TRO405 + + +JA4003_1 + + + +UH04.EXTERN_IN + +EXTERN +(Zulauf) + + + +UH04.EXTERN_IN->UH04.TRO400 + + +JA4000_1 + + + +UH04.EXTERN_IN->UH04.TRO418 + + +JA4010_1 + + + +UH05.TRO500 + +TRO500 +[Vario] +TRO 500 (Vario) - Stand: Vorbereitet für Umbau! + + + +UH05.TRO530 + +TRO530 +[Vario] +TRO 530 (Vario) + + + +UH05.TRO500->UH05.TRO530 + + +JA5001_2 Finger + + + +UH05.TRO501 + +TRO501 +[1Sep] +TRO 501 (1Sep) + Scanner (BX5101) + + + +UH05.TRO504 + +TRO504 +[1Sep] +TRO 504 (1Sep) + + + +UH05.TRO501->UH05.TRO504 + + +JA5002_1 + + + +UH05.TRO502 + +TRO502 +[Vario] +TRO 502 (Vario) - Stand: Vorbereitet für Umbau! + + + +UH05.TRO531 + +TRO531 +[Vario] +TRO 531 (Vario) + + + +UH05.TRO502->UH05.TRO531 + + +JA5000_2 Finger + + + +UH05.TRO503 + +TRO503 +[1Sep] +TRO 503 (1Sep)+ Scanner (BX5100) + + + +UH05.TRO503->UH05.TRO504 + + +JA5002_1 + + + +UH05.TRO505 + +TRO505 +[1Sep1Swi] +TRO 505 (1Sep1Switch) + Scanner (BX5102) + + + +UH05.TRO504->UH05.TRO505 + + +JA5002_2 + + + +UH05.TRO506 + +TRO506 +[Vario] +TRO 506 (Vario) + + + +UH05.TRO505->UH05.TRO506 + + +JA5003_1 + + + +UH05.TRO510 + +TRO510 +[1Sep1Swi] +TRO 510 (1Sep1Switch) + Scanner (BX5104) + + + +UH05.TRO505->UH05.TRO510 + + +JA5002_3 Dir2 + + + +UH05.TRO507 + +TRO507 +[1Sep] +TRO 507 (1Sep) + + + +UH05.TRO506->UH05.TRO507 + + +JA5003_2 Finger + + + +UH05.TRO508 + +TRO508 +[Vario] +TRO 508 (Vario)+Scanner(BX5103) + + + +UH05.TRO507->UH05.TRO508 + + +JA5004_1 + + + +UH05.EXTERN_OUT + +EXTERN +(Ablauf) + + + +UH05.TRO508->UH05.EXTERN_OUT + + +JA5004_2 + + + +UH05.TRO509 + +TRO509 +[1Sep] +TRO 509 (1Sep) + + + +UH05.TRO509->UH05.TRO510 + + +JA5002_3 + + + +UH05.TRO511 + +TRO511 +[1Sep] +TRO 511 (1Sep) + + + +UH05.TRO510->UH05.TRO511 + + +JA5005_1 + + + +UH05.TRO514 + +TRO514 +[1Sep1Swi] +TRO 514 (1Sep1Switch) + Scanner (BX5106) + + + +UH05.TRO510->UH05.TRO514 + + +JA5002_4 Dir2 + + + +UH05.TRO512 + +TRO512 +[Vario] +TRO 512 (Vario)+Scanner(BX5105) + + + +UH05.TRO511->UH05.TRO512 + + +JA5005_2 + + + +UH05.TRO512->UH05.EXTERN_OUT + + +JA5005_3 + + + +UH05.TRO513 + +TRO513 +[1Sep] +TRO 513 (1Sep) + + + +UH05.TRO513->UH05.TRO514 + + +JA5002_4 + + + +UH05.TRO515 + +TRO515 +[1Sep] +TRO 515 (1Sep) + + + +UH05.TRO514->UH05.TRO515 + + +JA5006_1 + + + +UH05.TRO518 + +TRO518 +[1Sep1Swi] +TRO 518 (1Sep1Switch) + Scanner (BX5108) + + + +UH05.TRO514->UH05.TRO518 + + +JA5002_5 Dir2 + + + +UH05.TRO516 + +TRO516 +[Vario] +TRO 516(Vario)+Scanner(BX5107) + + + +UH05.TRO515->UH05.TRO516 + + +JA5006_2 + + + +UH05.TRO516->UH05.EXTERN_OUT + + +JA5006_3 + + + +UH05.TRO517 + +TRO517 +[1Sep] +TRO 517 (1Sep) + + + +UH05.TRO517->UH05.TRO518 + + +JA5002_5 + + + +UH05.TRO519 + +TRO519 +[1Sep] +TRO 519 (1Sep) + + + +UH05.TRO518->UH05.TRO519 + + +JA5007_1 + + + +UH05.TRO522 + +TRO522 +[1Sep1Swi] +TRO 522 (1Sep1Switch) + Scanner (BX5110) + + + +UH05.TRO518->UH05.TRO522 + + +JA5002_6 Dir2 + + + +UH05.TRO520 + +TRO520 +[Vario] +TRO 520 (Vario)+Scanner(BX5109) + + + +UH05.TRO519->UH05.TRO520 + + +JA5007_2 + + + +UH05.TRO520->UH05.EXTERN_OUT + + +JA5007_3 + + + +UH05.TRO521 + +TRO521 +[1Sep] +TRO 521(1Sep) + + + +UH05.TRO521->UH05.TRO522 + + +JA5002_6 + + + +UH05.TRO523 + +TRO523 +[1Sep] +TRO 523 (1Sep) + + + +UH05.TRO522->UH05.TRO523 + + +JA5008_1 + + + +UH05.TRO526 + +TRO526 +[1Sep] +TRO 526 (1Sep) + Scanner (BX5112) + + + +UH05.TRO522->UH05.TRO526 + + +JA5002_7 Dir2 + + + +UH05.TRO524 + +TRO524 +[Vario] +TRO 524 (Vario)+Scanner(BX5231) + + + +UH05.TRO523->UH05.TRO524 + + +JA5008_2 + + + +UH05.TRO524->UH05.EXTERN_OUT + + +JA5008_3 + + + +UH05.TRO525 + +TRO525 +[1Sep] +TRO 525(1Sep) + + + +UH05.TRO525->UH05.TRO526 + + +JA5002_7 + + + +UH05.TRO527 + +TRO527 +[1Sep1Swi] +TRO 527 (1Sep1Switch) + + + +UH05.TRO526->UH05.TRO527 + + +JA5002_8 + + + +UH05.TRO528 + +TRO528 +[1Sep] +TRO 528 (1Sep) + + + +UH05.TRO527->UH05.TRO528 + + +JA5002_9 Dir2 + + + +UH05.TRO529 + +TRO529 +[1Sep] +TRO 529 (1Sep) + Scanner (BX5113) + + + +UH05.TRO528->UH05.TRO529 + + +JA5002_10 + + + +UH05.TRO529->UH05.TRO504 + + +JA5002_1 + + + +UH05.TRO530->UH05.TRO501 + + +JA5001_3 Finger + + + +UH05.TRO531->UH05.TRO503 + + +JA5000_3 Finger + + + +UH05.EXTERN_IN + +EXTERN +(Zulauf) + + + +UH05.EXTERN_IN->UH05.TRO500 + + +JA5001_1 + + + +UH05.EXTERN_IN->UH05.TRO502 + + +JA5000_1 + + + diff --git a/lib/create_dxf.py b/lib/create_dxf.py new file mode 100644 index 0000000..77d3533 --- /dev/null +++ b/lib/create_dxf.py @@ -0,0 +1,259 @@ +# -*- coding: utf-8 -*- +"""create_dxf.py — erzeugt eine DXF-Uebersicht aller TROs mit ihren Sensoren. + +Quelle sind die vom Skeleton-Generator erzeugten results/skeleton_UH0x.json +(Sensor-Positionen aus der Positions-JSON, Einheiten mit IO-Zuordnung). + +Je TRO-Einheit wird ein Block "TRO_BOX" (Rechteck + eingerahmter Name) +am Schwerpunkt seiner Sensoren eingefuegt; die TRO-Namen entsprechen der +Nummerierung des SCL-Grundgeruests (create_skel.py). Jeder Sensor wird als +Block "SENSOR" (Kreis + Name) an seiner x/y-Position eingefuegt und per +Linie mit seinem TRO verbunden. + +Block-Attribute (fuer Identifikation im CAD, teils unsichtbar): + TRO_BOX: NAME, FBTYPE (sichtbar) — UNIT, PLC, AREAS, SENSORS, IO (unsichtbar) + SENSOR: NAME (sichtbar) — ROLE, TRO, PLC (unsichtbar) + +Pfade ueber Umgebungsvariablen aus bin\\setenv.bat: + PV_RESULTS Eingabe (skeleton_UH0x.json) und Ausgabe (DXF) + +Mit --colors werden die TRO-Kaesten zusaetzlich nach FB-Typ eingefaerbt +(SOLID-Fuellung auf Layer TRO_FUELL, gleiche Palette wie im Topologie- +Graphen doc/TRO_Graph_UH01-UH05.dot); ohne den Schalter bleiben die +Kaesten ungefuellt. + +Aufruf: bin\\create_dxf.bat [--uh 1..5] [--out DATEI.dxf] [--colors] +""" + +import argparse +import json +import os +import sys +from pathlib import Path + +try: + import ezdxf + from ezdxf.enums import TextEntityAlignment +except ImportError: + sys.exit("ezdxf fehlt — bitte bin\\install_py.bat ausfuehren.") + +# ============================================================================ +# GLOBALE DEFINITIONEN (Geometrie in mm, Layer, Farben) +# ============================================================================ + +OUT_NAME = "ST500592_TROs.dxf" + +BOX_W = 2500 # TRO-Kasten Breite +BOX_H = 1200 # TRO-Kasten Hoehe +BOX_TEXT_H = 380 # Texthoehe TRO-Name +BOX_SUB_H = 220 # Texthoehe FB-Typ +SEN_RADIUS = 120 # Sensor-Kreisradius +SEN_TEXT_H = 150 # Texthoehe Sensorname +ATTR_MAXLEN = 250 # DXF-Attributwerte kuerzen + +LAYERS = { + "TRO": 7, # Kaesten (Farbe je PLC am Insert) + "TRO_FUELL": 7, # Kasten-Fuellung (Truecolor je FB-Typ) + "SENSOR": 8, # Sensoren mit TRO-Zuordnung + "SENSOR_FREI": 9, # Sensoren ohne Einheit (nur Position) + "VERBINDUNG": 253, # Linien Sensor -> TRO +} + +#: ACI-Farbe je Steuerung +PLC_COLOR = {1: 1, 2: 2, 3: 3, 4: 4, 5: 6} # rot, gelb, gruen, cyan, magenta + +#: Fuellfarbe je FB-Typ (Truecolor) — gleiche Palette wie im +#: Topologie-Graphen doc/TRO_Graph_UH01-UH05.dot +TYPE_COLOR = { + "FB_ILS_MTRO_1Sep": 0xD4E8FF, # hellblau + "FB_ILS_MTRO_1Sep_SSCC": 0xFFD4D4, # rot + "FB_ILS_MTRO_1Sep1Swi": 0xFFE4A0, # gelb (Weiche) + "FB_ILS_MTRO_1Sep2Swi": 0xFFC060, # orange (Weiche) + "FB_ILS_MTRO_2Sep1Swi": 0xFFE4A0, # gelb (Weiche) + "FB_ILS_MTRO_Vario": 0xE8D4F0, # violett + "FB_ILS_MTRO_Vario_workStation": 0xC0F0F0, # tuerkis + "FB_ILS_MTRO_PinStore_Auto": 0xD4F0D4, # gruen (Lager) + "FB_EmptyCarrBuffer": 0xD4F0D4, # gruen (Puffer) + "FB_Conveyor": 0xF0F0F0, # grau +} +TYPE_COLOR_DEFAULT = 0xF0F0F0 # grau (Sonstige/UNBEKANNT) + + +def type_color(fbtype): + for key in sorted(TYPE_COLOR, key=len, reverse=True): + if fbtype.startswith(key): + return TYPE_COLOR[key] + return TYPE_COLOR_DEFAULT + +# ============================================================================ + + +def project_paths(): + root = Path(os.environ.get("PROJECT", Path(__file__).resolve().parent.parent)) + results = Path(os.environ.get("PV_RESULTS", root / "results")) + return results + + +def build_blocks(doc): + """Blockdefinitionen TRO_BOX und SENSOR anlegen.""" + tro = doc.blocks.new(name="TRO_BOX") + w2, h2 = BOX_W / 2, BOX_H / 2 + tro.add_lwpolyline([(-w2, -h2), (w2, -h2), (w2, h2), (-w2, h2)], + close=True) + att = tro.add_attdef("NAME", height=BOX_TEXT_H) + att.set_placement((0, BOX_H * 0.12), align=TextEntityAlignment.MIDDLE_CENTER) + att = tro.add_attdef("FBTYPE", height=BOX_SUB_H) + att.set_placement((0, -BOX_H * 0.28), align=TextEntityAlignment.MIDDLE_CENTER) + for tag in ("UNIT", "PLC", "AREAS", "SENSORS", "IO"): + att = tro.add_attdef(tag, height=BOX_SUB_H) + att.set_placement((0, 0), align=TextEntityAlignment.MIDDLE_CENTER) + att.dxf.invisible = 1 + + sen = doc.blocks.new(name="SENSOR") + sen.add_circle((0, 0), SEN_RADIUS) + att = sen.add_attdef("NAME", height=SEN_TEXT_H) + att.set_placement((SEN_RADIUS * 1.4, SEN_RADIUS * 1.2), + align=TextEntityAlignment.BOTTOM_LEFT) + for tag in ("ROLE", "TRO", "PLC"): + att = sen.add_attdef(tag, height=SEN_TEXT_H) + att.set_placement((0, 0), align=TextEntityAlignment.MIDDLE_CENTER) + att.dxf.invisible = 1 + + +def instance_names(skel, uh_digit): + """TRO-Instanznamen je Einheit — identische Nummerierung wie + render_scl() in create_skel.py (Conveyor verbraucht eine lfd. Nummer).""" + names = {} + seq = 0 + for u in skel["units"]: + if u["fbType"] == "UNBEKANNT": + names[u["unit"]] = u["unit"] # kein TRO-Name vergeben + continue + seq += 1 + if u["fbType"] == "FB_Conveyor": + names[u["unit"]] = f"fbConveyor{u['unit'][1:]}" + else: + names[u["unit"]] = f"TRO{uh_digit}{seq:02d}" + return names + + +def cut(s): + return s if len(s) <= ATTR_MAXLEN else s[:ATTR_MAXLEN - 3] + "..." + + +def draw_plc(msp, skel, n, colors=False): + """Alle Einheiten + Sensoren einer Steuerung zeichnen.""" + uh = f"UH0{n}" + color = PLC_COLOR[n] + names = instance_names(skel, str(n)) + + # Sensoren je Einheit sammeln (nur mit Position) + unit_sensors = {} + free_sensors = [] + for s in skel["sensors"]: + if not s.get("pos"): + continue + if s.get("unit"): + unit_sensors.setdefault(s["unit"], []).append(s) + else: + free_sensors.append(s) + + boxes = lines = 0 + for u in skel["units"]: + sens = unit_sensors.get(u["unit"], []) + if sens: # Schwerpunkt der Sensoren + cx = sum(s["pos"][0] for s in sens) / len(sens) + cy = sum(s["pos"][1] for s in sens) / len(sens) + elif u.get("pos"): + cx, cy = u["pos"][0], u["pos"][1] + else: + print(f" {uh} {u['unit']}: keine Position — uebersprungen") + continue + + io_txt = ";".join(f"{role}={','.join(v)}" + for role, v in sorted(u["io"].items())) + if colors: + # Fuellung in FB-Typ-Farbe (vor dem Insert -> liegt dahinter) + w2, h2 = BOX_W / 2, BOX_H / 2 + msp.add_solid( + [(cx - w2, cy - h2), (cx + w2, cy - h2), + (cx - w2, cy + h2), (cx + w2, cy + h2)], + dxfattribs={"layer": "TRO_FUELL", + "true_color": type_color(u["fbType"])}) + blk = msp.add_blockref("TRO_BOX", (cx, cy), + dxfattribs={"layer": "TRO", "color": color}) + blk.add_auto_attribs({ + "NAME": names[u["unit"]], + "FBTYPE": u["fbType"].replace("FB_ILS_MTRO_", "").replace("FB_", ""), + "UNIT": u["unit"], + "PLC": uh, + "AREAS": cut(",".join(a["id"] for a in u["areas"])), + "SENSORS": cut(",".join(s["id"] for s in sens)), + "IO": cut(io_txt), + }) + boxes += 1 + + for s in sens: + sx, sy = s["pos"][0], s["pos"][1] + sb = msp.add_blockref("SENSOR", (sx, sy), + dxfattribs={"layer": "SENSOR", + "color": color}) + sb.add_auto_attribs({ + "NAME": s["id"], + "ROLE": s.get("role") or "", + "TRO": names[u["unit"]], + "PLC": uh, + }) + msp.add_line((sx, sy), (cx, cy), + dxfattribs={"layer": "VERBINDUNG"}) + lines += 1 + + for s in free_sensors: + sb = msp.add_blockref("SENSOR", (s["pos"][0], s["pos"][1]), + dxfattribs={"layer": "SENSOR_FREI"}) + sb.add_auto_attribs({ + "NAME": s["id"], + "ROLE": s.get("role") or "", + "TRO": "", + "PLC": uh, + }) + + print(f" {uh}: {boxes} TRO-Kaesten, {lines} Sensor-Verbindungen, " + f"{len(free_sensors)} freie Sensoren") + + +def main(): + ap = argparse.ArgumentParser(description=__doc__) + ap.add_argument("--uh", type=int, choices=range(1, 6), + help="nur diese Steuerung (1..5), sonst alle") + ap.add_argument("--out", default=OUT_NAME, + help=f"Ausgabedatei (Default: {OUT_NAME})") + ap.add_argument("--colors", action="store_true", + help="TRO-Kaesten nach FB-Typ einfaerben " + "(Palette wie doc/TRO_Graph_UH01-UH05.dot)") + args = ap.parse_args() + + results = project_paths() + doc = ezdxf.new("R2010", setup=True) + doc.header["$INSUNITS"] = 4 # Millimeter + for name, aci in LAYERS.items(): + doc.layers.add(name, color=aci) + build_blocks(doc) + msp = doc.modelspace() + + print("Erzeuge DXF aus Skeleton-Dateien:") + for n in ([args.uh] if args.uh else range(1, 6)): + skel_file = results / f"skeleton_UH0{n}.json" + if not skel_file.exists(): + sys.exit(f"FEHLER: {skel_file} fehlt — zuerst bin\\create_skel.bat " + f"ausfuehren.") + skel = json.loads(skel_file.read_text(encoding="utf-8")) + draw_plc(msp, skel, n, colors=args.colors) + + out = results / args.out + doc.saveas(out) + print(f"DXF geschrieben: {out}") + + +if __name__ == "__main__": + main() diff --git a/lib/create_skel.py b/lib/create_skel.py new file mode 100644 index 0000000..9ee3972 --- /dev/null +++ b/lib/create_skel.py @@ -0,0 +1,808 @@ +# -*- coding: utf-8 -*- +"""create_skel.py — Skeleton-Generator fuer die JSON-Zwischendatei und ein +SCL-Grundgeruest, abgeleitet aus den Eingabelisten in data/. + +Datenquellen (Pfade ueber Umgebungsvariablen aus bin\\setenv.bat): + PV_DATA Ordner mit den Eingabelisten + ST500592_10_5-14_ILS-_TIA.xlsx (PLC Tags + Constants) + ST500592_10_5-9_ILS_positions.json (Positionen, VERW, mappings) + PV_RESULTS Zielordner fuer die erzeugten Dateien + PV_CFG Ordner mit den Konfigurationsdateien, geladen beim Start: + skel.cfg (JSON) Dateinamen, Vokabular, FB-Typ-Regeln + skel_scl.cfg (INI-Style) SCL-Templates, zeilenweise + lesbar; jede [sektion] = ein Template, + Inhalt verbatim (Einrueckung/Leerzeilen + gehoeren zum Template) + Fehlende Dateien fallen auf die eingebauten Defaults zurueck. + +Erzeugt je Steuerung UH01..UH05: + skeleton_UH0x.json JSON-Zwischendatei-Skeleton (Kap. 14 im + Json_Layout-Konzept.md) + FB_Main_skel_UH0x.scl SCL-Grundgeruest (VAR-Deklaration + Aufrufe) + FB_CallSensors_skel_UH0x.scl Sensor-Aufrufe + +Mit --con-ini bzw. --con-json wird zusaetzlich die TRO-Topologie +(Routing / Zusammenhalt, Format hmf-connect-v1) aus data\\connect.ini +bzw. data\\connect.json eingelesen und als "topology"-Abschnitt in die +Skeleton-JSONs uebernommen (Verbindungen, offene Enden und je TRO die +aufgeloeste JamArea-Verdrahtung). + +Aufruf: bin\\create_skel.bat [--uh 1..5] [--no-scl] [--con-ini | --con-json] +""" + +import argparse +import configparser +import json +import os +import re +import sys +from collections import defaultdict +from pathlib import Path + +try: + import openpyxl +except ImportError: + sys.exit("openpyxl fehlt — bitte bin\\install_py.bat ausfuehren.") + +# ============================================================================ +# GLOBALE DEFINITIONEN (eingebaute Defaults) +# Alle folgenden Bloecke sind bewusst als Modul-Konstanten definiert. Sie +# sind zugleich der Inhalt von cfg\\skel.cfg (JSON) — load_cfg() liest diese +# Datei aus PV_CFG beim Programmstart und ersetzt die Defaults hier 1:1 +# durch ihren Inhalt. Ohne skel.cfg (z.B. Erststart, Datei geloescht) bleiben +# die Defaults unten aktiv, das Skript funktioniert also auch dann. +# ============================================================================ + +#: Dateinamen der Eingabelisten ({n} = ILS-Nummer 1..5) +FILES = { + "tia_xlsx": "ST500592_10_5-14_ILS-{n}_TIA.xlsx", + "positions_json": "ST500592_10_5-9_ILS_positions.json", + # Routing / Zusammenhalt der TROs (hmf-connect-v1, extrahiert aus + # doc/TRO_Graph_UH01-UH05.dot) — fuer die kuenftige Topologie-Auswertung + "connect_json": "connect.json", + "connect_ini": "connect.ini", +} + +#: VERW-Vokabular (Positions-JSON) -> Signalrolle +#: (siehe doc/EA-Listen-Analyse.md, Abschnitt "Verwendung von Positionen") +VERW_ROLES = { + "In sep": "sensorInSep", + "Sep": "stopperOutput", + "Jam detector": "sensorJam", + "Jam detector (LP)": "sensorJam", + "jam detector (LP)": "sensorJam", + "ES branch": "switchOutput", + "ES brunch": "switchOutput", # Schreibvariante in den Daten + "conveyor full": "sensorConvFull", + "MT in Position": "sensorCarrInPos", + "MT in position": "sensorCarrInPos", + "Finger in position": "sensorFinger", + "Finger in Position": "sensorFinger", + "PIN query": "sensorPinQuery", + "Rad dreht ": "sensorWheel", + "Rad dreht": "sensorWheel", +} + +#: Fallback: Regex auf den Kommentartext -> Signalrolle +#: (falls kein VERW vorliegt, z.B. Signal nicht im Positions-JSON) +COMMENT_ROLES = [ + (r"^in Separator", "sensorInSep"), + (r"^Separator", "stopperOutput"), + (r"Stausensor|Staumelder", "sensorJam"), + (r"AE Abzweig", "switchOutput"), + (r"F.?rderer voll", "sensorConvFull"), + (r"MT in Position", "sensorCarrInPos"), + (r"Mitnehmerfinger|Finger in", "sensorFinger"), + (r"Pin Abfrage|Pr.?fung MT Pos", "sensorPinQuery"), + (r"Rad dreht", "sensorWheel"), + (r"^Motor ", "motorOutput"), + (r"MSS ausgel", "motorProtection"), +] + +#: Regeln zur FB-Typ-Bestimmung je Einheit. +#: Reihenfolge = Prioritaet; "roles" muessen alle vorhanden sein. +FBTYPE_RULES = [ + {"roles": ["sensorPinQuery"], "fbType": "FB_ILS_MTRO_PinStore_Auto"}, + {"roles": ["sensorFinger"], "fbType": "FB_ILS_MTRO_Vario"}, + {"roles": ["sensorCarrInPos"], "fbType": "FB_ILS_MTRO_Vario"}, + {"roles": ["switchOutput", "sensorInSep"], "fbType": "FB_ILS_MTRO_1Sep1Swi"}, + {"roles": ["sensorInSep"], "fbType": "FB_ILS_MTRO_1Sep"}, + {"roles": ["motorOutput"], "fbType": "FB_Conveyor"}, + {"roles": ["motorProtection"], "fbType": "FB_Conveyor"}, +] + +#: Erkennung der Foerdertechnik-Einheit (M-Nummer) im Kommentartext +UNIT_RE = r"\b(KR|CV)[-\s]{0,2}(P?[MK]\d{4}(?:_[A-Z])?)\b" + +#: Erkennung der Bereichsgruppen im Kommentartext +AREA_RES = [ + (r"Block ?(\d\.\d(?:\.\d)?)", "pinStoreBlock", "Block {m}"), + (r"\bLS ?(\d)\b", "loadingStation", "LS{m}"), + (r"\bWS ?(\d\.\d)\b", "workStation", "WS{m}"), + (r"\bUZ(\d{4})\b", "safetyZone", "UZ{m}"), +] + +# ---------------------------------------------------------------------------- +# SCL-Templates: die "ueblichen Codebloecke" fuer die Aufrufe in FB_Main / +# FB_CallSensors. Platzhalter im str.format()-Stil. +# Eingebaute Defaults — die gepflegte, zeilenweise lesbare Fassung liegt in +# cfg\skel_scl.cfg (INI-Style) und ueberschreibt diese beim Programmstart. +# ---------------------------------------------------------------------------- +SCL_TEMPLATES = { + # VAR-Deklaration einer Instanz + "var_decl": ' {inst} : "{fbtype}"; // {comment}\n', + + # Aufruf FB_ILS_MTRO_1Sep (Standard-Separator) + "call_1sep": """\ + REGION {inst} ({shorttype}) — {comment} + #{inst}.stInSeparator1.Settings.nSeparatorNo := "cSep{tro_no}.1"; + #{inst}.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #{inst}.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #{inst}.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #{inst}.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #{inst}.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cIn{sen_in_sep}"]; + #{inst}.stInSenJam2 := "DB_Inputs".Sensors["cIn{sen_jam}"]; + + #{inst}.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #{inst}(nInMainTroNo := "cMainTro{tro_no}", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.stData, + arInOutJamExit2 := "DB_JamArea{tro_no}".stJam{tro_no}_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea{tro_no}".stJam{tro_no}_2.stData, + xOutStopper1 => "{stopper}", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro{tro_no}"], + stInOutHMI := "DB_Interface_HMI".stTRO.{inst}); + END_REGION + +""", + + # Aufruf FB_ILS_MTRO_1Sep1Swi (Separator + Weiche) + "call_1sep1swi": """\ + REGION {inst} ({shorttype}) — {comment} + #{inst}.stInSeparator1.Settings.nSeparatorNo := "cSep{tro_no}.1"; + #{inst}.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #{inst}.stInSeparator1.Settings.tTrailingTime := T#100ms; // TODO Timing + #{inst}.stInSeparator1.Settings.tHandlingTime := T#50ms; // TODO Timing + #{inst}.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #{inst}.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cIn{sen_in_sep}"]; + #{inst}.stInSenJam2 := "DB_Inputs".Sensors["cIn{sen_jam}"]; + #{inst}.stInSwitch1.Settings.nSwitchNo := "cSwi{tro_no}.1"; + + #{inst}(nInMainTroNo := "cMainTro{tro_no}", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun1 := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.stData, + arInOutJamExit2 := "DB_JamArea{tro_no}".stJam{tro_no}_2.arCarrier, // TODO Topologie (Dir1) + stInOutJamExit2 := "DB_JamArea{tro_no}".stJam{tro_no}_2.stData, + arInOutJamExit3 := "DB_JamArea{tro_no}".stJam{tro_no}_3.arCarrier, // TODO Topologie (Dir2) + stInOutJamExit3 := "DB_JamArea{tro_no}".stJam{tro_no}_3.stData, + xOutStopper1 => "{stopper}", + xOutSw1ExTo3 => "{switch_out}", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro{tro_no}"], + stInOutHMI := "DB_Interface_HMI".stTRO.{inst}); + END_REGION + +""", + + # Aufruf FB_ILS_MTRO_Vario (Kettenfoerderer) + "call_vario": """\ + REGION {inst} ({shorttype}) — {comment} + #{inst}.stInSeparator1.Settings.nSeparatorNo := "cSep{tro_no}.1"; + #{inst}.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #{inst}.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cIn{sen_in_sep}"]; + #{inst}.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cIn{sen_carr_in_pos}"]; + #{inst}.stInVario.stSenFinger := "DB_Inputs".Sensors["cIn{sen_finger}"]; + #{inst}.stInVario.stSenJam := "DB_Inputs".Sensors["cIn{sen_jam}"]; + + #{inst}(nInMainTroNo := "cMainTro{tro_no}", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea{tro_no}".stJam{tro_no}_1.stData, + arInOutJamFinger := "DB_JamArea{tro_no}".stJam{tro_no}_2.arCarrier, // TODO Topologie + xOutStopper => "{stopper}", + xOutVarioMotor => "{motor}", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro{tro_no}"], + stInOutHMI := "DB_Interface_HMI".stTRO.{inst}); + END_REGION + +""", + + # Aufruf FB_Conveyor (Kreisel / Foerderer ohne TRO-Logik) + "call_conveyor": """\ + REGION {inst} — {comment} + #{inst}.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #{inst}.Settings.xGridActive := FALSE; // TODO Grid + #{inst}.Settings.sMotorProtectName := '{motor_protection}'; + + #{inst}(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "{motor_protection}", + xInPowerContactor := "{motor}", + stInOutHMI := "DB_Interface_HMI".stConveyors.{inst}); + END_REGION + +""", + + # Eintrag in FB_CallSensors je Sensor + "call_sensor": """\ + // {comment} + #fbSensorInput(stInSensorHW := "{bmk}", + nInSensorNo := "cIn{bmk}", + stInOutSensor := "DB_Inputs".Sensors["cIn{bmk}"]); +""", + + # Rahmen FB_Main + "fb_main_frame": """\ +FUNCTION_BLOCK "FB_Main_skel_{uh}" +{{ S7_Optimized_Access := 'TRUE' }} +VERSION : 0.1 +// ============================================================ +// AUTOMATISCH GENERIERTES GRUNDGERUEST — create_skel.py +// Quelle: E/A-Listen {uh} (data/) +// TODO-Marken kennzeichnen manuell zu ergaenzende Stellen +// (Timings, Topologie/JamAreas, Safety, Release, Priority). +// ============================================================ + VAR +{var_block} END_VAR + +BEGIN +{call_block}END_FUNCTION_BLOCK +""", + + # Rahmen FB_CallSensors + "fb_sensors_frame": """\ +FUNCTION_BLOCK "FB_CallSensors_skel_{uh}" +{{ S7_Optimized_Access := 'TRUE' }} +VERSION : 0.1 +// AUTOMATISCH GENERIERT — create_skel.py ({count} Sensoren) + VAR + fbSensorInput : "FB_SensorInput"; + END_VAR + +BEGIN +{call_block}END_FUNCTION_BLOCK +""", +} + +# Zuordnung FB-Typ -> Template-Schluessel +FBTYPE_TEMPLATE = { + "FB_ILS_MTRO_1Sep": "call_1sep", + "FB_ILS_MTRO_1Sep1Swi": "call_1sep1swi", + "FB_ILS_MTRO_Vario": "call_vario", + "FB_ILS_MTRO_PinStore_Auto": "call_1sep", # eigenes Template folgt spaeter + "FB_Conveyor": "call_conveyor", +} + +# ============================================================================ +# Ende der globalen Definitionen +# ============================================================================ + +#: Schluessel in skel.cfg -> Modul-Konstante, die beim Laden ersetzt wird +_CFG_KEYS = { + "files": "FILES", + "verw_roles": "VERW_ROLES", + "comment_roles": "COMMENT_ROLES", + "fbtype_rules": "FBTYPE_RULES", + "unit_re": "UNIT_RE", + "area_res": "AREA_RES", + "scl_templates": "SCL_TEMPLATES", + "fbtype_template": "FBTYPE_TEMPLATE", +} + + +def load_cfg(): + """Laedt cfg\\skel.cfg (JSON) aus PV_CFG und ersetzt die globalen + Definitionen (FILES, VERW_ROLES, ..., SCL_TEMPLATES) durch ihren Inhalt. + + Fehlt PV_CFG oder die Datei, bleiben die eingebauten Defaults oben aktiv + (Cold-Start-Faehigkeit ohne Konfigurationsdatei). + """ + cfg_dir = os.environ.get("PV_CFG", Path(__file__).resolve().parent.parent / "cfg") + cfg_file = Path(cfg_dir) / "skel.cfg" + if not cfg_file.exists(): + print(f"Hinweis: {cfg_file} nicht gefunden — verwende eingebaute Defaults.") + return + + print(f"Lade Konfiguration: {cfg_file}") + data = json.loads(cfg_file.read_text(encoding="utf-8")) + + globals_ = globals() + for cfg_key, const_name in _CFG_KEYS.items(): + if cfg_key not in data: + continue + value = data[cfg_key] + # Listen von Listen (comment_roles, fbtype_rules, area_res) als + # Tupel normalisieren, damit das Unpacking im Code unveraendert bleibt + if const_name in ("COMMENT_ROLES", "AREA_RES"): + value = [tuple(item) for item in value] + globals_[const_name] = value + + +def load_scl_cfg(): + """Laedt die SCL-Templates aus PV_CFG\\skel_scl.cfg (INI-Style). + + Format: jede [sektion] ist ein Template-Schluessel (var_decl, call_1sep, + ...); der Sektionsinhalt wird VERBATIM uebernommen — Einrueckung und + Leerzeilen (auch am Blockende) gehoeren zum Template. Zeilen, die mit + ';' beginnen, sind Kommentare. SCL selbst beginnt nie mit ';', daher + ist das kollisionsfrei. + + Fehlt die Datei, bleiben die Templates aus skel.cfg bzw. den eingebauten + Defaults aktiv. + """ + cfg_dir = os.environ.get("PV_CFG", Path(__file__).resolve().parent.parent / "cfg") + cfg_file = Path(cfg_dir) / "skel_scl.cfg" + if not cfg_file.exists(): + print(f"Hinweis: {cfg_file} nicht gefunden — " + f"verwende SCL-Templates aus skel.cfg/Defaults.") + return + + print(f"Lade SCL-Templates: {cfg_file}") + templates = {} + name, buf = None, [] + + def flush(): + if name is not None: + templates[name] = "\n".join(buf) + "\n" + + for line in cfg_file.read_text(encoding="utf-8").splitlines(): + if line.startswith(";"): + continue + m = re.fullmatch(r"\[(\w+)\]\s*", line) + if m: + flush() + name, buf = m.group(1), [] + elif name is not None: + buf.append(line) + flush() + SCL_TEMPLATES.update(templates) + print(f"SCL-Templates geladen: {', '.join(templates)}") + + +def project_paths(): + """Pfade aus den setenv.bat-Umgebungsvariablen (mit Fallbacks).""" + root = Path(os.environ.get("PROJECT", Path(__file__).resolve().parent.parent)) + data_dir = Path(os.environ.get("PV_DATA", root / "data")) + results = Path(os.environ.get("PV_RESULTS", root / "results")) + results.mkdir(parents=True, exist_ok=True) + return root, data_dir, results + + +# ---------------------------------------------------------------------------- +# Einlesen +# ---------------------------------------------------------------------------- + +def read_positions(data_dir): + """Positions-JSON: (BMK, SPS) -> {verw, pos, cabinet, bezeichnung}.""" + path = data_dir / FILES["positions_json"] + if not path.exists(): + print(f"WARNUNG: {path} nicht gefunden — Positionen/VERW entfallen.") + return {} + data = json.loads(path.read_text(encoding="utf-8")) + index = {} + for section in ("sensors", "schaltschrank_elemente"): + for key, val in data.get(section, {}).items(): + if "@" not in key: + continue + bmk, sps = key.rsplit("@", 1) + index[(bmk, sps)] = { + "verw": (val.get("VERW") or "").strip(), + "pos": val.get("pos"), + "bezeichnung": val.get("BEZEICHNUNG") or "", + "kennzeichnung": val.get("KENNZEICHNUNG") or "", + } + # mappings: Verteiler -> [BMK@SPS] umdrehen zu (BMK, SPS) -> Verteiler + for dist, members in data.get("mappings", {}).items(): + for key in members: + if "@" not in key: + continue + bmk, sps = key.rsplit("@", 1) + index.setdefault((bmk, sps), {})["cabinet"] = dist + return index + + +def read_tia(data_dir, n): + """TIA-Liste ILS-n: Liste von Tag-Dicts + Konstanten-Map.""" + path = data_dir / FILES["tia_xlsx"].format(n=n) + wb = openpyxl.load_workbook(path, read_only=True, data_only=True) + tags = [] + for row in wb["PLC Tags"].iter_rows(min_row=2, values_only=True): + name, _path, dtype, addr, comment = (tuple(row) + (None,) * 5)[:5] + if not name: + continue + tags.append({ + "name": str(name), + "dataType": str(dtype) if dtype else "Bool", + "address": str(addr) if addr else "", + "comment": str(comment) if comment else "", + }) + constants = {} + if "Constants" in wb.sheetnames: + for row in wb["Constants"].iter_rows(min_row=2, values_only=True): + cname, _path, _dt, value = (tuple(row) + (None,) * 4)[:4] + if cname: + constants[str(cname)] = value + return tags, constants + + +# ---------------------------------------------------------------------------- +# Connect-Daten (Topologie, Format hmf-connect-v1) +# ---------------------------------------------------------------------------- + +def expand_jam(short): + """JA0101_1 -> "DB_JamArea0101".stJam0101_1 ; sonst unveraendert.""" + m = re.fullmatch(r"JA(\w+)_(\w+)", short) + if m: + return f'"DB_JamArea{m.group(1)}".stJam{m.group(1)}_{m.group(2)}' + return short + + +def read_connect_json(data_dir): + """connect.json -> {UHxx: {nodes, connections, externals}}.""" + path = data_dir / FILES["connect_json"] + data = json.loads(path.read_text(encoding="utf-8")) + return data.get("plcs", {}) + + +def read_connect_ini(data_dir): + """connect.ini -> gleiche Struktur wie read_connect_json().""" + path = data_dir / FILES["connect_ini"] + cp = configparser.ConfigParser(interpolation=None) + cp.optionxform = str # Gross-/Kleinschreibung der TRO-Namen erhalten + cp.read(path, encoding="utf-8") + plcs = {} + for section in cp.sections(): + uh, _, part = section.partition(".") + plc = plcs.setdefault(uh, {"nodes": {}, "connections": [], + "externals": []}) + if part == "nodes": + for name, val in cp[section].items(): + fbtype, _, comment = (x.strip() for x in val.partition("|")) + plc["nodes"][name] = {"fbType": fbtype, "comment": comment} + elif part == "connections": + for _, val in cp[section].items(): + fields = [x.strip() for x in val.split("|")] + src, _, dst = (x.strip() for x in fields[0].partition("->")) + plc["connections"].append({ + "from": src, "to": dst, "jamArea": fields[1], + "kind": fields[2] if len(fields) > 2 else "normal", + "dbRef": expand_jam(fields[1])}) + elif part == "externals": + for _, val in cp[section].items(): + route, _, jam = (x.strip() for x in val.partition("|")) + src, _, dst = (x.strip() for x in route.partition("->")) + node, direction = (dst, "in") if src == "EXTERN" else (src, "out") + plc["externals"].append({ + "node": node, "direction": direction, "jamArea": jam, + "dbRef": expand_jam(jam)}) + return plcs + + +def derive_topology(topo): + """Bereitet die Connect-Daten einer Steuerung fuer das Skeleton auf: + je TRO die aufgeloeste JamArea-Verdrahtung (entries/exits).""" + tros = {name: {"id": name, "fbType": nd["fbType"], "comment": nd["comment"], + "entries": [], "exits": []} + for name, nd in topo["nodes"].items()} + for c in topo["connections"]: + db = c.get("dbRef") or expand_jam(c["jamArea"]) + if c["from"] in tros: + tros[c["from"]]["exits"].append( + {"jamArea": c["jamArea"], "dbRef": db, "to": c["to"], + "kind": c["kind"]}) + if c["to"] in tros: + tros[c["to"]]["entries"].append( + {"jamArea": c["jamArea"], "dbRef": db, "from": c["from"], + "kind": c["kind"]}) + for e in topo["externals"]: + if e["node"] not in tros: + continue + db = e.get("dbRef") or expand_jam(e["jamArea"]) + side = "entries" if e["direction"] == "in" else "exits" + peer = "from" if e["direction"] == "in" else "to" + tros[e["node"]][side].append( + {"jamArea": e["jamArea"], "dbRef": db, peer: "EXTERN", + "kind": "extern"}) + return { + "format": "hmf-connect-v1", + "tros": [tros[k] for k in sorted(tros)], + "connections": topo["connections"], + "externals": topo["externals"], + } + + +# ---------------------------------------------------------------------------- +# Klassifikation +# ---------------------------------------------------------------------------- + +def classify_role(tag, posinfo): + """Signalrolle: primaer VERW-Vokabular, sonst Kommentar-Heuristik.""" + verw = (posinfo or {}).get("verw", "") + if verw in VERW_ROLES: + return VERW_ROLES[verw] + for pattern, role in COMMENT_ROLES: + if re.search(pattern, tag["comment"], re.I): + return role + return "" + + +def extract_unit(comment): + """M-Nummer der Foerdertechnik-Einheit aus dem Kommentar.""" + m = re.search(UNIT_RE, comment) + if m: + return m.group(2), m.group(1) # ("M0101", "KR") + return None, None + + +def extract_areas(comment): + """Bereichsgruppen (Block/LS/WS/UZ) aus dem Kommentar.""" + found = [] + for pattern, kind, fmt in AREA_RES: + for m in re.finditer(pattern, comment, re.I): + found.append({"id": fmt.format(m=m.group(1)), "kind": kind}) + return found + + +def guess_fbtype(roles): + """FB-Typ einer Einheit aus der Menge ihrer Signalrollen.""" + for rule in FBTYPE_RULES: + if all(r in roles for r in rule["roles"]): + return rule["fbType"] + return "UNBEKANNT" + + +# ---------------------------------------------------------------------------- +# Skeleton-Aufbau +# ---------------------------------------------------------------------------- + +def build_skeleton(n, tags, constants, positions, connect=None): + """Baut das JSON-Skeleton fuer eine Steuerung (ILS-n = UH0n).""" + uh = f"UH0{n}" + sps = str(n) + + sensors = [] + units = defaultdict(lambda: {"signals": [], "roles": set(), "areas": [], + "kind": None, "pos": None, "cabinets": set()}) + areas = defaultdict(lambda: {"kind": None, "members": set(), + "cabinets": set()}) + unassigned = [] + + for tag in tags: + posinfo = positions.get((tag["name"], sps)) + role = classify_role(tag, posinfo) + unit_id, unit_kind = extract_unit(tag["comment"]) + area_hits = extract_areas(tag["comment"]) + cabinet = (posinfo or {}).get("cabinet") + + entry = { + "id": tag["name"], + "constant": f"cIn{tag['name']}" if tag["address"].startswith("%E") else None, + "hwAddress": tag["address"], + "comment": tag["comment"], + "role": role or None, + "unit": unit_id, + "cabinet": cabinet, + "pos": (posinfo or {}).get("pos"), + } + if tag["address"].startswith("%E"): + sensors.append(entry) + + if unit_id: + u = units[unit_id] + u["kind"] = unit_kind + u["signals"].append(entry) + if role: + u["roles"].add(role) + if u["pos"] is None and entry["pos"]: + u["pos"] = entry["pos"] + if cabinet: + u["cabinets"].add(cabinet) + for a in area_hits: + if a not in u["areas"]: + u["areas"].append(a) + elif not area_hits and not role: + unassigned.append(tag["name"]) + + for a in area_hits: + ar = areas[a["id"]] + ar["kind"] = a["kind"] + if unit_id: + ar["members"].add(unit_id) + if cabinet: + ar["cabinets"].add(cabinet) + + unit_list = [] + for unit_id in sorted(units): + u = units[unit_id] + fbtype = guess_fbtype(u["roles"]) + io = {} + for sig in u["signals"]: + if sig["role"]: + io.setdefault(sig["role"], []).append(sig["id"]) + unit_list.append({ + "unit": unit_id, + "unitKind": u["kind"], + "fbType": fbtype, + "areas": u["areas"], + "cabinet": sorted(u["cabinets"])[0] if u["cabinets"] else None, + "pos": u["pos"], + "io": io, + "signalCount": len(u["signals"]), + }) + + area_list = [{ + "id": aid, + "kind": a["kind"], + "members": sorted(a["members"]), + "cabinets": sorted(a["cabinets"]), + } for aid, a in sorted(areas.items())] + + skel = { + "$schema": "hmf-layout-v1.schema.json", + "generatedBy": "create_skel.py", + "plc": {"id": uh, "configName": f"=A01+{uh}-KF00"}, + "statistics": { + "tags": len(tags), + "sensors": len(sensors), + "constants": len(constants), + "units": len(unit_list), + "areas": len(area_list), + "unassignedSignals": len(unassigned), + }, + "sensors": sensors, + "units": unit_list, + "areas": area_list, + "unassignedSignals": sorted(unassigned), + "todo": [ + "connections[] (Topologie) manuell ergaenzen oder aus SCL extrahieren", + "Timings, Priority, Release, customCode manuell pflegen", + "TRO-IDs den Einheiten zuweisen (Schema TRO)", + ], + } + + if connect is not None: + topo = connect.get(uh) + if topo: + skel["topology"] = derive_topology(topo) + skel["statistics"]["troNodes"] = len(topo["nodes"]) + skel["statistics"]["connections"] = len(topo["connections"]) + skel["statistics"]["externals"] = len(topo["externals"]) + skel["todo"] = [ + "topology[] aus connect-Daten uebernommen — TRO-IDs den " + "Einheiten (units[]) noch zuordnen", + "Timings, Priority, Release, customCode manuell pflegen", + ] + else: + print(f"WARNUNG: keine Connect-Daten fuer {uh} gefunden.") + + return skel + + +# ---------------------------------------------------------------------------- +# SCL-Rendering +# ---------------------------------------------------------------------------- + +def first(io, role, default="BGxxxx"): + vals = io.get(role) + return vals[0] if vals else default + + +def render_scl(skeleton, uh): + """FB_Main- und FB_CallSensors-Grundgeruest aus den Templates.""" + var_block = [] + call_block = [] + tro_seq = 0 + for u in skeleton["units"]: + fbtype = u["fbType"] + if fbtype == "UNBEKANNT": + continue + tro_seq += 1 + inst = f"TRO{uh[-1]}{tro_seq:02d}" if fbtype != "FB_Conveyor" \ + else f"fbConveyor{u['unit'][1:]}" + comment = f"{u['unitKind']}-{u['unit']}" + \ + (f" / {u['areas'][0]['id']}" if u["areas"] else "") + var_block.append(SCL_TEMPLATES["var_decl"].format( + inst=inst, fbtype=fbtype, comment=comment)) + + tpl = SCL_TEMPLATES[FBTYPE_TEMPLATE[fbtype]] + io = u["io"] + call_block.append(tpl.format( + inst=inst, + shorttype=fbtype.replace("FB_ILS_MTRO_", "").replace("FB_", ""), + comment=comment, + tro_no=f"{uh[-1]}{tro_seq:02d}", + sen_in_sep=first(io, "sensorInSep"), + sen_jam=first(io, "sensorJam"), + sen_finger=first(io, "sensorFinger"), + sen_carr_in_pos=first(io, "sensorCarrInPos"), + stopper=first(io, "stopperOutput", "MBxxxx"), + switch_out=first(io, "switchOutput", "MBxxxx"), + motor=first(io, "motorOutput", "MAxxxx"), + motor_protection=first(io, "motorProtection", "FCxxxx"), + )) + + fb_main = SCL_TEMPLATES["fb_main_frame"].format( + uh=uh, var_block="".join(var_block), call_block="".join(call_block)) + + sensor_calls = [SCL_TEMPLATES["call_sensor"].format( + bmk=s["id"], comment=s["comment"]) for s in skeleton["sensors"]] + fb_sensors = SCL_TEMPLATES["fb_sensors_frame"].format( + uh=uh, count=len(sensor_calls), call_block="".join(sensor_calls)) + + return fb_main, fb_sensors + + +# ---------------------------------------------------------------------------- +# main +# ---------------------------------------------------------------------------- + +def main(): + ap = argparse.ArgumentParser(description=__doc__) + ap.add_argument("--uh", type=int, choices=range(1, 6), + help="nur diese Steuerung (1..5), sonst alle") + ap.add_argument("--no-scl", action="store_true", + help="nur JSON-Skeleton, kein SCL-Grundgeruest") + con = ap.add_mutually_exclusive_group() + con.add_argument("--con-ini", action="store_true", + help="Topologie aus data\\connect.ini uebernehmen") + con.add_argument("--con-json", action="store_true", + help="Topologie aus data\\connect.json uebernehmen") + args = ap.parse_args() + + load_cfg() + load_scl_cfg() + root, data_dir, results = project_paths() + print(f"Daten: {data_dir}") + print(f"Results: {results}") + + positions = read_positions(data_dir) + print(f"Positions-JSON: {len(positions)} Signale indiziert") + + connect = None + if args.con_ini or args.con_json: + src = FILES["connect_ini"] if args.con_ini else FILES["connect_json"] + if not (data_dir / src).exists(): + sys.exit(f"FEHLER: {data_dir / src} nicht gefunden.") + connect = (read_connect_ini if args.con_ini + else read_connect_json)(data_dir) + total = sum(len(p["connections"]) for p in connect.values()) + print(f"Connect-Daten: {src} — {len(connect)} PLCs, " + f"{total} Verbindungen") + + for n in ([args.uh] if args.uh else range(1, 6)): + uh = f"UH0{n}" + tags, constants = read_tia(data_dir, n) + skel = build_skeleton(n, tags, constants, positions, connect) + + out_json = results / f"skeleton_{uh}.json" + out_json.write_text(json.dumps(skel, indent=2, ensure_ascii=False), + encoding="utf-8", newline="\n") + s = skel["statistics"] + topo_info = (f", {s['connections']} Verbindungen" + if "connections" in s else "") + print(f"{uh}: {s['tags']} Tags, {s['units']} Einheiten, " + f"{s['areas']} Bereiche{topo_info} -> {out_json.name}") + + if not args.no_scl: + fb_main, fb_sensors = render_scl(skel, uh) + (results / f"FB_Main_skel_{uh}.scl").write_text( + fb_main, encoding="utf-8", newline="\n") + (results / f"FB_CallSensors_skel_{uh}.scl").write_text( + fb_sensors, encoding="utf-8", newline="\n") + print(f"{uh}: FB_Main_skel_{uh}.scl, FB_CallSensors_skel_{uh}.scl") + + +if __name__ == "__main__": + main() diff --git a/requirements.txt b/requirements.txt new file mode 100644 index 0000000..936b88d --- /dev/null +++ b/requirements.txt @@ -0,0 +1,3 @@ +# Python-Abhaengigkeiten HundM_Fortna +openpyxl>=3.1 +ezdxf>=1.3 diff --git a/results/FB_CallSensors_skel_UH01.scl b/results/FB_CallSensors_skel_UH01.scl new file mode 100644 index 0000000..ffb2754 --- /dev/null +++ b/results/FB_CallSensors_skel_UH01.scl @@ -0,0 +1,1158 @@ +FUNCTION_BLOCK "FB_CallSensors_skel_UH01" +{ S7_Optimized_Access := 'TRUE' } +VERSION : 0.1 +// AUTOMATISCH GENERIERT — create_skel.py (287 Sensoren) + VAR + fbSensorInput : "FB_SensorInput"; + END_VAR + +BEGIN + // DT Anlage Aus + #fbSensorInput(stInSensorHW := "SF0000", + nInSensorNo := "cInSF0000", + stInOutSensor := "DB_Inputs".Sensors["cInSF0000"]); + // LDT Anlage Ein + #fbSensorInput(stInSensorHW := "SF0001", + nInSensorNo := "cInSF0001", + stInOutSensor := "DB_Inputs".Sensors["cInSF0001"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0002", + nInSensorNo := "cInSF0002", + stInOutSensor := "DB_Inputs".Sensors["cInSF0002"]); + // DT Lampentest + #fbSensorInput(stInSensorHW := "SF0003", + nInSensorNo := "cInSF0003", + stInOutSensor := "DB_Inputs".Sensors["cInSF0003"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0004", + nInSensorNo := "cInBP0004", + stInOutSensor := "DB_Inputs".Sensors["cInBP0004"]); + // Phasenausfall 400V + #fbSensorInput(stInSensorHW := "DI0005", + nInSensorNo := "cInDI0005", + stInOutSensor := "DB_Inputs".Sensors["cInDI0005"]); + // Vorsicherung 400V UC0110 + #fbSensorInput(stInSensorHW := "DI0006", + nInSensorNo := "cInDI0006", + stInOutSensor := "DB_Inputs".Sensors["cInDI0006"]); + // Vorsicherung 400V UC0111 + #fbSensorInput(stInSensorHW := "DI0007", + nInSensorNo := "cInDI0007", + stInOutSensor := "DB_Inputs".Sensors["cInDI0007"]); + // Vorsicherung 400V UC011 + #fbSensorInput(stInSensorHW := "DI0010", + nInSensorNo := "cInDI0010", + stInOutSensor := "DB_Inputs".Sensors["cInDI0010"]); + // Feedback Hauptschütze aktiv +UC0110 + #fbSensorInput(stInSensorHW := "DI0011", + nInSensorNo := "cInDI0011", + stInOutSensor := "DB_Inputs".Sensors["cInDI0011"]); + // Feedback Hauptschütze aktiv +UC0111 + #fbSensorInput(stInSensorHW := "DI0012", + nInSensorNo := "cInDI0012", + stInOutSensor := "DB_Inputs".Sensors["cInDI0012"]); + // Feedback Hauptschütze aktiv + #fbSensorInput(stInSensorHW := "DI0013", + nInSensorNo := "cInDI0013", + stInOutSensor := "DB_Inputs".Sensors["cInDI0013"]); + // Feedback Koppelrelais E-Stop-IF (QA0660/QA0661) + #fbSensorInput(stInSensorHW := "DI0014", + nInSensorNo := "cInDI0014", + stInOutSensor := "DB_Inputs".Sensors["cInDI0014"]); + // Vorsicherung 400V + #fbSensorInput(stInSensorHW := "DI0016", + nInSensorNo := "cInDI0016", + stInOutSensor := "DB_Inputs".Sensors["cInDI0016"]); + // Sicherung Lampe 1EA0012 & 1EA0013 + #fbSensorInput(stInSensorHW := "DI0017", + nInSensorNo := "cInDI0017", + stInOutSensor := "DB_Inputs".Sensors["cInDI0017"]); + // Vorsicherung 24V OK (FC021) + #fbSensorInput(stInSensorHW := "DI0021", + nInSensorNo := "cInDI0021", + stInOutSensor := "DB_Inputs".Sensors["cInDI0021"]); + // Vorsicherung 24V OK (FC022) + #fbSensorInput(stInSensorHW := "DI0022", + nInSensorNo := "cInDI0022", + stInOutSensor := "DB_Inputs".Sensors["cInDI0022"]); + // Vorsicherung 24V OK (FC023) + #fbSensorInput(stInSensorHW := "DI0023", + nInSensorNo := "cInDI0023", + stInOutSensor := "DB_Inputs".Sensors["cInDI0023"]); + // Vorsicherung 24V OK (FC024) + #fbSensorInput(stInSensorHW := "DI0024", + nInSensorNo := "cInDI0024", + stInOutSensor := "DB_Inputs".Sensors["cInDI0024"]); + // Schlüsselschalter LS 1 + #fbSensorInput(stInSensorHW := "SF0025", + nInSensorNo := "cInSF0025", + stInOutSensor := "DB_Inputs".Sensors["cInSF0025"]); + // Schlüsselschalter LS 2 + #fbSensorInput(stInSensorHW := "SF0026", + nInSensorNo := "cInSF0026", + stInOutSensor := "DB_Inputs".Sensors["cInSF0026"]); + // Reset UZ0101 + #fbSensorInput(stInSensorHW := "SF0031", + nInSensorNo := "cInSF0031", + stInOutSensor := "DB_Inputs".Sensors["cInSF0031"]); + // Freigabe UZ0102 + #fbSensorInput(stInSensorHW := "SF0032", + nInSensorNo := "cInSF0032", + stInOutSensor := "DB_Inputs".Sensors["cInSF0032"]); + // Reset UZ0102 + #fbSensorInput(stInSensorHW := "SF0033", + nInSensorNo := "cInSF0033", + stInOutSensor := "DB_Inputs".Sensors["cInSF0033"]); + // IF BMZ "fire alarm" + #fbSensorInput(stInSensorHW := "DI0034", + nInSensorNo := "cInDI0034", + stInOutSensor := "DB_Inputs".Sensors["cInDI0034"]); + // IF BST "No fire alarm" + #fbSensorInput(stInSensorHW := "DI0035", + nInSensorNo := "cInDI0035", + stInOutSensor := "DB_Inputs".Sensors["cInDI0035"]); + // IF BST "Non fault" + #fbSensorInput(stInSensorHW := "DI0036", + nInSensorNo := "cInDI0036", + stInOutSensor := "DB_Inputs".Sensors["cInDI0036"]); + // IF BST "FPC opened" + #fbSensorInput(stInSensorHW := "DI0037", + nInSensorNo := "cInDI0037", + stInOutSensor := "DB_Inputs".Sensors["cInDI0037"]); + // Strahler ein/aus LS1 + #fbSensorInput(stInSensorHW := "SF0041", + nInSensorNo := "cInSF0041", + stInOutSensor := "DB_Inputs".Sensors["cInSF0041"]); + // Schnittstelle RFID (from Rielec "station ready") + #fbSensorInput(stInSensorHW := "DI0042", + nInSensorNo := "cInDI0042", + stInOutSensor := "DB_Inputs".Sensors["cInDI0042"]); + // Reset LS1 + #fbSensorInput(stInSensorHW := "SF0043", + nInSensorNo := "cInSF0043", + stInOutSensor := "DB_Inputs".Sensors["cInSF0043"]); + // Ladeschleife aktivieren LS1 + #fbSensorInput(stInSensorHW := "SF0044", + nInSensorNo := "cInSF0044", + stInOutSensor := "DB_Inputs".Sensors["cInSF0044"]); + // Strahler ein/aus LS2 + #fbSensorInput(stInSensorHW := "SF0046", + nInSensorNo := "cInSF0046", + stInOutSensor := "DB_Inputs".Sensors["cInSF0046"]); + // Schnittstelle RFID (from Rielec "bypass mode") + #fbSensorInput(stInSensorHW := "DI0047", + nInSensorNo := "cInDI0047", + stInOutSensor := "DB_Inputs".Sensors["cInDI0047"]); + // Positionsschalter Ladeschleife 1 eingefahren + #fbSensorInput(stInSensorHW := "SF0050", + nInSensorNo := "cInSF0050", + stInOutSensor := "DB_Inputs".Sensors["cInSF0050"]); + // Positionsschalter Ladeschleife 1 ausgefahren + #fbSensorInput(stInSensorHW := "SF0051", + nInSensorNo := "cInSF0051", + stInOutSensor := "DB_Inputs".Sensors["cInSF0051"]); + // Positionsschalter Ladeschleife 2 eingefahren + #fbSensorInput(stInSensorHW := "SF0052", + nInSensorNo := "cInSF0052", + stInOutSensor := "DB_Inputs".Sensors["cInSF0052"]); + // Positionsschalter Ladeschleife 2 ausgefahren + #fbSensorInput(stInSensorHW := "SF0053", + nInSensorNo := "cInSF0053", + stInOutSensor := "DB_Inputs".Sensors["cInSF0053"]); + // Reset LS2 + #fbSensorInput(stInSensorHW := "SF0054", + nInSensorNo := "cInSF0054", + stInOutSensor := "DB_Inputs".Sensors["cInSF0054"]); + // Ladeschleife aktivieren LS2 + #fbSensorInput(stInSensorHW := "SF0055", + nInSensorNo := "cInSF0055", + stInOutSensor := "DB_Inputs".Sensors["cInSF0055"]); + // MSS ausgelöst FC0057 (ILS-CVM0100) + #fbSensorInput(stInSensorHW := "FC0057", + nInSensorNo := "cInFC0057", + stInOutSensor := "DB_Inputs".Sensors["cInFC0057"]); + // MSS ausgelöst FC0060 (ILS-KR-M0101) + #fbSensorInput(stInSensorHW := "FC0060", + nInSensorNo := "cInFC0060", + stInOutSensor := "DB_Inputs".Sensors["cInFC0060"]); + // MSS ausgelöst FC0061 (ILS-KR-M0102) Auslagerkreisel + #fbSensorInput(stInSensorHW := "FC0061", + nInSensorNo := "cInFC0061", + stInOutSensor := "DB_Inputs".Sensors["cInFC0061"]); + // MSS ausgelöst FC0062 (ILS-CV-M0103) + #fbSensorInput(stInSensorHW := "FC0062", + nInSensorNo := "cInFC0062", + stInOutSensor := "DB_Inputs".Sensors["cInFC0062"]); + // MSS ausgelöst FC0063 (ILS-CV-M0105) + #fbSensorInput(stInSensorHW := "FC0063", + nInSensorNo := "cInFC0063", + stInOutSensor := "DB_Inputs".Sensors["cInFC0063"]); + // MSS ausgelöst FC0064 (ILS-CV M0106) + #fbSensorInput(stInSensorHW := "FC0064", + nInSensorNo := "cInFC0064", + stInOutSensor := "DB_Inputs".Sensors["cInFC0064"]); + // MSS ausgelöst FC0065 (ILS-CV M0107) + #fbSensorInput(stInSensorHW := "FC0065", + nInSensorNo := "cInFC0065", + stInOutSensor := "DB_Inputs".Sensors["cInFC0065"]); + // MSS ausgelöst FC0066 (ILS-CV M0109) + #fbSensorInput(stInSensorHW := "FC0066", + nInSensorNo := "cInFC0066", + stInOutSensor := "DB_Inputs".Sensors["cInFC0066"]); + // MSS ausgelöst FC0067 (ILS-CV M0110) + #fbSensorInput(stInSensorHW := "FC0067", + nInSensorNo := "cInFC0067", + stInOutSensor := "DB_Inputs".Sensors["cInFC0067"]); + // MSS ausgelöst FC0070 + #fbSensorInput(stInSensorHW := "FC0070", + nInSensorNo := "cInFC0070", + stInOutSensor := "DB_Inputs".Sensors["cInFC0070"]); + // MSS ausgelöst FC0072 + #fbSensorInput(stInSensorHW := "FC0072", + nInSensorNo := "cInFC0072", + stInOutSensor := "DB_Inputs".Sensors["cInFC0072"]); + // MSS ausgelöst FC0074 + #fbSensorInput(stInSensorHW := "FC0074", + nInSensorNo := "cInFC0074", + stInOutSensor := "DB_Inputs".Sensors["cInFC0074"]); + // MSS ausgelöst FC0076 + #fbSensorInput(stInSensorHW := "FC0076", + nInSensorNo := "cInFC0076", + stInOutSensor := "DB_Inputs".Sensors["cInFC0076"]); + // Meldekontakt 400V Motor+Bremse + #fbSensorInput(stInSensorHW := "DI0100", + nInSensorNo := "cInDI0100", + stInOutSensor := "DB_Inputs".Sensors["cInDI0100"]); + // Vorsicherung 24V OK (FC101) + #fbSensorInput(stInSensorHW := "DI0101", + nInSensorNo := "cInDI0101", + stInOutSensor := "DB_Inputs".Sensors["cInDI0101"]); + // Vorsicherung 24V OK (FC102) + #fbSensorInput(stInSensorHW := "DI0102", + nInSensorNo := "cInDI0102", + stInOutSensor := "DB_Inputs".Sensors["cInDI0102"]); + // Feedback Hauptschütze aktiv (QA0920/QA0921) + #fbSensorInput(stInSensorHW := "DI0106", + nInSensorNo := "cInDI0106", + stInOutSensor := "DB_Inputs".Sensors["cInDI0106"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0107", + nInSensorNo := "cInBP0107", + stInOutSensor := "DB_Inputs".Sensors["cInBP0107"]); + // IF BST "No fire alarm" + #fbSensorInput(stInSensorHW := "DI0110", + nInSensorNo := "cInDI0110", + stInOutSensor := "DB_Inputs".Sensors["cInDI0110"]); + // IF BST "Non fault" + #fbSensorInput(stInSensorHW := "DI0111", + nInSensorNo := "cInDI0111", + stInOutSensor := "DB_Inputs".Sensors["cInDI0111"]); + // IF BST "FPC opened" + #fbSensorInput(stInSensorHW := "DI0112", + nInSensorNo := "cInDI0112", + stInOutSensor := "DB_Inputs".Sensors["cInDI0112"]); + // Feedback Koppelrelais E-Stop-IF (QA0922/QA0923) + #fbSensorInput(stInSensorHW := "DI0114", + nInSensorNo := "cInDI0114", + stInOutSensor := "DB_Inputs".Sensors["cInDI0114"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0117", + nInSensorNo := "cInSF0117", + stInOutSensor := "DB_Inputs".Sensors["cInSF0117"]); + // Bereichshalt UZ1101 + #fbSensorInput(stInSensorHW := "SF0120", + nInSensorNo := "cInSF0120", + stInOutSensor := "DB_Inputs".Sensors["cInSF0120"]); + // Reset UZ1101 + #fbSensorInput(stInSensorHW := "SF0121", + nInSensorNo := "cInSF0121", + stInOutSensor := "DB_Inputs".Sensors["cInSF0121"]); + // Bereichshalt UZ1103 + #fbSensorInput(stInSensorHW := "SF0124", + nInSensorNo := "cInSF0124", + stInOutSensor := "DB_Inputs".Sensors["cInSF0124"]); + // Reset UZ1103 + #fbSensorInput(stInSensorHW := "SF0125", + nInSensorNo := "cInSF0125", + stInOutSensor := "DB_Inputs".Sensors["cInSF0125"]); + // Bereichshalt UZ1104 + #fbSensorInput(stInSensorHW := "SF0126", + nInSensorNo := "cInSF0126", + stInOutSensor := "DB_Inputs".Sensors["cInSF0126"]); + // Reset UZ1104 + #fbSensorInput(stInSensorHW := "SF0127", + nInSensorNo := "cInSF0127", + stInOutSensor := "DB_Inputs".Sensors["cInSF0127"]); + // Bereichshalt UZ1105 + #fbSensorInput(stInSensorHW := "SF0130", + nInSensorNo := "cInSF0130", + stInOutSensor := "DB_Inputs".Sensors["cInSF0130"]); + // Reset UZ1105 + #fbSensorInput(stInSensorHW := "SF0131", + nInSensorNo := "cInSF0131", + stInOutSensor := "DB_Inputs".Sensors["cInSF0131"]); + // MSS ausgelöst FC0140 (KR-M4204) + #fbSensorInput(stInSensorHW := "FC0140", + nInSensorNo := "cInFC0140", + stInOutSensor := "DB_Inputs".Sensors["cInFC0140"]); + // MSS ausgelöst FC0141 (CV-M4503) + #fbSensorInput(stInSensorHW := "FC0141", + nInSensorNo := "cInFC0141", + stInOutSensor := "DB_Inputs".Sensors["cInFC0141"]); + // MSS ausgelöst FC0142 (CV-M4502) + #fbSensorInput(stInSensorHW := "FC0142", + nInSensorNo := "cInFC0142", + stInOutSensor := "DB_Inputs".Sensors["cInFC0142"]); + // MSS ausgelöst FC0143 (CV-M4403) + #fbSensorInput(stInSensorHW := "FC0143", + nInSensorNo := "cInFC0143", + stInOutSensor := "DB_Inputs".Sensors["cInFC0143"]); + // MSS ausgelöst FC0144 (CV-M4501) + #fbSensorInput(stInSensorHW := "FC0144", + nInSensorNo := "cInFC0144", + stInOutSensor := "DB_Inputs".Sensors["cInFC0144"]); + // MSS ausgelöst FC0145 (CV-M4104) + #fbSensorInput(stInSensorHW := "FC0145", + nInSensorNo := "cInFC0145", + stInOutSensor := "DB_Inputs".Sensors["cInFC0145"]); + // MSS ausgelöst FC0146 (CV-M4103) + #fbSensorInput(stInSensorHW := "FC0146", + nInSensorNo := "cInFC0146", + stInOutSensor := "DB_Inputs".Sensors["cInFC0146"]); + // MSS ausgelöst FC0147 (CV-M4203_A) + #fbSensorInput(stInSensorHW := "FC0147", + nInSensorNo := "cInFC0147", + stInOutSensor := "DB_Inputs".Sensors["cInFC0147"]); + // MSS ausgelöst FC0150 (CV-M4302_B) + #fbSensorInput(stInSensorHW := "FC0150", + nInSensorNo := "cInFC0150", + stInOutSensor := "DB_Inputs".Sensors["cInFC0150"]); + // MSS ausgelöst FC0151 (CV-M4402_B) + #fbSensorInput(stInSensorHW := "FC0151", + nInSensorNo := "cInFC0151", + stInOutSensor := "DB_Inputs".Sensors["cInFC0151"]); + // MSS ausgelöst FC0152 (CV-M4103_B) + #fbSensorInput(stInSensorHW := "FC0152", + nInSensorNo := "cInFC0152", + stInOutSensor := "DB_Inputs".Sensors["cInFC0152"]); + // MSS ausgelöst FC0153 (CV-M4203_B) + #fbSensorInput(stInSensorHW := "FC0153", + nInSensorNo := "cInFC0153", + stInOutSensor := "DB_Inputs".Sensors["cInFC0153"]); + // MSS ausgelöst FC0154 (CV-M4302_A) + #fbSensorInput(stInSensorHW := "FC0154", + nInSensorNo := "cInFC0154", + stInOutSensor := "DB_Inputs".Sensors["cInFC0154"]); + // MSS ausgelöst FC0155 (CV-M4402_A) + #fbSensorInput(stInSensorHW := "FC0155", + nInSensorNo := "cInFC0155", + stInOutSensor := "DB_Inputs".Sensors["cInFC0155"]); + // in Separator LS 1 + #fbSensorInput(stInSensorHW := "BG0280", + nInSensorNo := "cInBG0280", + stInOutSensor := "DB_Inputs".Sensors["cInBG0280"]); + // in Separator Beladeposition 1, LS 1 + #fbSensorInput(stInSensorHW := "BG0282", + nInSensorNo := "cInBG0282", + stInOutSensor := "DB_Inputs".Sensors["cInBG0282"]); + // in Separator Beladeposition 2, LS 1 + #fbSensorInput(stInSensorHW := "BG0283", + nInSensorNo := "cInBG0283", + stInOutSensor := "DB_Inputs".Sensors["cInBG0283"]); + // Rad dreht (KR- LS 1) + #fbSensorInput(stInSensorHW := "BG0284", + nInSensorNo := "cInBG0284", + stInOutSensor := "DB_Inputs".Sensors["cInBG0284"]); + // Stausensor Staubereich nach Beladung voll + #fbSensorInput(stInSensorHW := "BG0285", + nInSensorNo := "cInBG0285", + stInOutSensor := "DB_Inputs".Sensors["cInBG0285"]); + // Stausensor Staubereich voll Einfahrt Kreisel + #fbSensorInput(stInSensorHW := "BG0286", + nInSensorNo := "cInBG0286", + stInOutSensor := "DB_Inputs".Sensors["cInBG0286"]); + // LS 1 Sensor 2m ausgefahren + #fbSensorInput(stInSensorHW := "BG0287", + nInSensorNo := "cInBG0287", + stInOutSensor := "DB_Inputs".Sensors["cInBG0287"]); + // Freigabe MT UZ0110-1 + #fbSensorInput(stInSensorHW := "SF0305", + nInSensorNo := "cInSF0305", + stInOutSensor := "DB_Inputs".Sensors["cInSF0305"]); + // Beladeposition 2 + #fbSensorInput(stInSensorHW := "SF0306", + nInSensorNo := "cInSF0306", + stInOutSensor := "DB_Inputs".Sensors["cInSF0306"]); + // MSS ausgelöst FC0320 Kreisel + #fbSensorInput(stInSensorHW := "FC0320", + nInSensorNo := "cInFC0320", + stInOutSensor := "DB_Inputs".Sensors["cInFC0320"]); + // MSS ausgelöst FC0321 Stützfuß LS1 + #fbSensorInput(stInSensorHW := "FC0321", + nInSensorNo := "cInFC0321", + stInOutSensor := "DB_Inputs".Sensors["cInFC0321"]); + // Stützfuß hat Endlage unten erreicht + #fbSensorInput(stInSensorHW := "SF0322", + nInSensorNo := "cInSF0322", + stInOutSensor := "DB_Inputs".Sensors["cInSF0322"]); + // Stützfuß hat Endlage oben erreicht + #fbSensorInput(stInSensorHW := "SF0323", + nInSensorNo := "cInSF0323", + stInOutSensor := "DB_Inputs".Sensors["cInSF0323"]); + // SEW MOVIMOT OK LS1 + #fbSensorInput(stInSensorHW := "DI0327", + nInSensorNo := "cInDI0327", + stInOutSensor := "DB_Inputs".Sensors["cInDI0327"]); + // Ladeschleife einfahren UZ0110-2 + #fbSensorInput(stInSensorHW := "SF0330", + nInSensorNo := "cInSF0330", + stInOutSensor := "DB_Inputs".Sensors["cInSF0330"]); + // Ladeschleife ausfahren UZ0110-2 + #fbSensorInput(stInSensorHW := "SF0331", + nInSensorNo := "cInSF0331", + stInOutSensor := "DB_Inputs".Sensors["cInSF0331"]); + // Freigabe MT ausfahren UZ0110-2 + #fbSensorInput(stInSensorHW := "SF0332", + nInSensorNo := "cInSF0332", + stInOutSensor := "DB_Inputs".Sensors["cInSF0332"]); + // Stützfuß ab LS1 + #fbSensorInput(stInSensorHW := "SF0333", + nInSensorNo := "cInSF0333", + stInOutSensor := "DB_Inputs".Sensors["cInSF0333"]); + // Stützfuß auf LS1 + #fbSensorInput(stInSensorHW := "SF0334", + nInSensorNo := "cInSF0334", + stInOutSensor := "DB_Inputs".Sensors["cInSF0334"]); + // in Separator LS2 + #fbSensorInput(stInSensorHW := "BG0340", + nInSensorNo := "cInBG0340", + stInOutSensor := "DB_Inputs".Sensors["cInBG0340"]); + // in Separator Beladeposition 1, LS 2 + #fbSensorInput(stInSensorHW := "BG0342", + nInSensorNo := "cInBG0342", + stInOutSensor := "DB_Inputs".Sensors["cInBG0342"]); + // in Separator + #fbSensorInput(stInSensorHW := "BG0343", + nInSensorNo := "cInBG0343", + stInOutSensor := "DB_Inputs".Sensors["cInBG0343"]); + // Rad dreht (KR- LS 2) + #fbSensorInput(stInSensorHW := "BG0344", + nInSensorNo := "cInBG0344", + stInOutSensor := "DB_Inputs".Sensors["cInBG0344"]); + // Stausensor Staubereich nach Beladung voll + #fbSensorInput(stInSensorHW := "BG0345", + nInSensorNo := "cInBG0345", + stInOutSensor := "DB_Inputs".Sensors["cInBG0345"]); + // Stausensor 2 (KR-M1102) + #fbSensorInput(stInSensorHW := "BG0346", + nInSensorNo := "cInBG0346", + stInOutSensor := "DB_Inputs".Sensors["cInBG0346"]); + // LS 2 Sensor 2m ausgefahren + #fbSensorInput(stInSensorHW := "BG0347", + nInSensorNo := "cInBG0347", + stInOutSensor := "DB_Inputs".Sensors["cInBG0347"]); + // Freigabe MT UZ0111-1 + #fbSensorInput(stInSensorHW := "SF0365", + nInSensorNo := "cInSF0365", + stInOutSensor := "DB_Inputs".Sensors["cInSF0365"]); + // Beladeposition 2 + #fbSensorInput(stInSensorHW := "SF0366", + nInSensorNo := "cInSF0366", + stInOutSensor := "DB_Inputs".Sensors["cInSF0366"]); + // MSS ausgelöst FC0380 Kreisel + #fbSensorInput(stInSensorHW := "FC0380", + nInSensorNo := "cInFC0380", + stInOutSensor := "DB_Inputs".Sensors["cInFC0380"]); + // MSS ausgelöst FC0381 Stützfuß LS2 + #fbSensorInput(stInSensorHW := "FC0381", + nInSensorNo := "cInFC0381", + stInOutSensor := "DB_Inputs".Sensors["cInFC0381"]); + // Stützfuß hat Endlage unten erreicht + #fbSensorInput(stInSensorHW := "SF0382", + nInSensorNo := "cInSF0382", + stInOutSensor := "DB_Inputs".Sensors["cInSF0382"]); + // Stützfuß hat Endlage oben erreicht + #fbSensorInput(stInSensorHW := "SF0383", + nInSensorNo := "cInSF0383", + stInOutSensor := "DB_Inputs".Sensors["cInSF0383"]); + // SEW MOVIMOT OK LS2 + #fbSensorInput(stInSensorHW := "DI0387", + nInSensorNo := "cInDI0387", + stInOutSensor := "DB_Inputs".Sensors["cInDI0387"]); + // Ladeschleife einfahren UZ0111-2 + #fbSensorInput(stInSensorHW := "SF0390", + nInSensorNo := "cInSF0390", + stInOutSensor := "DB_Inputs".Sensors["cInSF0390"]); + // Ladeschleife ausfahren UZ0111-2 + #fbSensorInput(stInSensorHW := "SF0391", + nInSensorNo := "cInSF0391", + stInOutSensor := "DB_Inputs".Sensors["cInSF0391"]); + // Freigabe MT UZ0111-2 + #fbSensorInput(stInSensorHW := "SF0392", + nInSensorNo := "cInSF0392", + stInOutSensor := "DB_Inputs".Sensors["cInSF0392"]); + // Stützfuß ab LS2 + #fbSensorInput(stInSensorHW := "SF0393", + nInSensorNo := "cInSF0393", + stInOutSensor := "DB_Inputs".Sensors["cInSF0393"]); + // Stützfuß auf LS2 + #fbSensorInput(stInSensorHW := "SF0394", + nInSensorNo := "cInSF0394", + stInOutSensor := "DB_Inputs".Sensors["cInSF0394"]); + // Not Halt Kanal 1 UH01 + #fbSensorInput(stInSensorHW := "SF0400", + nInSensorNo := "cInSF0400", + stInOutSensor := "DB_Inputs".Sensors["cInSF0400"]); + // Not Halt Kanal 1 UZ0101 + #fbSensorInput(stInSensorHW := "SF0401", + nInSensorNo := "cInSF0401", + stInOutSensor := "DB_Inputs".Sensors["cInSF0401"]); + // Not Halt Kanal 1 UZ0102 + #fbSensorInput(stInSensorHW := "SF0402", + nInSensorNo := "cInSF0402", + stInOutSensor := "DB_Inputs".Sensors["cInSF0402"]); + // Not Halt Kanal 1 LS 1 UZ0103 + #fbSensorInput(stInSensorHW := "SF0403", + nInSensorNo := "cInSF0403", + stInOutSensor := "DB_Inputs".Sensors["cInSF0403"]); + // Not Halt Kanal 2 UH01 + #fbSensorInput(stInSensorHW := "SF0404", + nInSensorNo := "cInSF0404", + stInOutSensor := "DB_Inputs".Sensors["cInSF0404"]); + // Not Halt Kanal 2 UZ0101 + #fbSensorInput(stInSensorHW := "SF0405", + nInSensorNo := "cInSF0405", + stInOutSensor := "DB_Inputs".Sensors["cInSF0405"]); + // Not Halt Kanal 2 UZ0102 + #fbSensorInput(stInSensorHW := "SF0406", + nInSensorNo := "cInSF0406", + stInOutSensor := "DB_Inputs".Sensors["cInSF0406"]); + // Not Halt Kanal 2 LS 1 UZ0103 + #fbSensorInput(stInSensorHW := "SF0407", + nInSensorNo := "cInSF0407", + stInOutSensor := "DB_Inputs".Sensors["cInSF0407"]); + // Not Halt Kanal 1 LS 2 UZ0104 + #fbSensorInput(stInSensorHW := "SF0470", + nInSensorNo := "cInSF0470", + stInOutSensor := "DB_Inputs".Sensors["cInSF0470"]); + // Not Halt Schnittstelle CH1 (Reserve) + #fbSensorInput(stInSensorHW := "SF0471", + nInSensorNo := "cInSF0471", + stInOutSensor := "DB_Inputs".Sensors["cInSF0471"]); + // Not Halt Kanal 2 LS 2 UZ0104 + #fbSensorInput(stInSensorHW := "SF0474", + nInSensorNo := "cInSF0474", + stInOutSensor := "DB_Inputs".Sensors["cInSF0474"]); + // Not Halt Schnittstelle CH2 (Reserve) + #fbSensorInput(stInSensorHW := "SF0475", + nInSensorNo := "cInSF0475", + stInOutSensor := "DB_Inputs".Sensors["cInSF0475"]); + // Not Halt Kanal 1 UC011 + #fbSensorInput(stInSensorHW := "SF0710", + nInSensorNo := "cInSF0710", + stInOutSensor := "DB_Inputs".Sensors["cInSF0710"]); + // Not Halt Kanal 2 UC011 + #fbSensorInput(stInSensorHW := "SF0714", + nInSensorNo := "cInSF0714", + stInOutSensor := "DB_Inputs".Sensors["cInSF0714"]); + // Not Halt Schnittstelle CH1 (from UH06) + #fbSensorInput(stInSensorHW := "SF0781", + nInSensorNo := "cInSF0781", + stInOutSensor := "DB_Inputs".Sensors["cInSF0781"]); + // Not Halt Schnittstelle CH2 (from UH0X) + #fbSensorInput(stInSensorHW := "SF0785", + nInSensorNo := "cInSF0785", + stInOutSensor := "DB_Inputs".Sensors["cInSF0785"]); + // Not Halt Kanal 1 UZ0110-1 + #fbSensorInput(stInSensorHW := "SF1640", + nInSensorNo := "cInSF1640", + stInOutSensor := "DB_Inputs".Sensors["cInSF1640"]); + // Not Halt Kanal 2 UZ0110-1 + #fbSensorInput(stInSensorHW := "SF1644", + nInSensorNo := "cInSF1644", + stInOutSensor := "DB_Inputs".Sensors["cInSF1644"]); + // Not Halt Kanal 1 UZ0111-1 + #fbSensorInput(stInSensorHW := "SF1950", + nInSensorNo := "cInSF1950", + stInOutSensor := "DB_Inputs".Sensors["cInSF1950"]); + // Not Halt Kanal 2 UZ0111-1 + #fbSensorInput(stInSensorHW := "SF1954", + nInSensorNo := "cInSF1954", + stInOutSensor := "DB_Inputs".Sensors["cInSF1954"]); + // Sensor Förderer voll (ILS-CV M4104) + #fbSensorInput(stInSensorHW := "BG3000", + nInSensorNo := "cInBG3000", + stInOutSensor := "DB_Inputs".Sensors["cInBG3000"]); + // Stausensor 1 (ILS-CV M4104) + #fbSensorInput(stInSensorHW := "BG3001", + nInSensorNo := "cInBG3001", + stInOutSensor := "DB_Inputs".Sensors["cInBG3001"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4103_A) + #fbSensorInput(stInSensorHW := "BG3002", + nInSensorNo := "cInBG3002", + stInOutSensor := "DB_Inputs".Sensors["cInBG3002"]); + // in Separator 1 (ILS-CV M4103_A) + #fbSensorInput(stInSensorHW := "BG3003", + nInSensorNo := "cInBG3003", + stInOutSensor := "DB_Inputs".Sensors["cInBG3003"]); + // MT in Position (ILS-CV M4103_A) + #fbSensorInput(stInSensorHW := "BG3004", + nInSensorNo := "cInBG3004", + stInOutSensor := "DB_Inputs".Sensors["cInBG3004"]); + // Stausensor (ILS-CV M4103_A) + #fbSensorInput(stInSensorHW := "BG3005", + nInSensorNo := "cInBG3005", + stInOutSensor := "DB_Inputs".Sensors["cInBG3005"]); + // Sensor Förderer voll (ILS-CV M4103_A) + #fbSensorInput(stInSensorHW := "BG3006", + nInSensorNo := "cInBG3006", + stInOutSensor := "DB_Inputs".Sensors["cInBG3006"]); + // Rad dreht (ILS-KR-M4204) + #fbSensorInput(stInSensorHW := "BG3007", + nInSensorNo := "cInBG3007", + stInOutSensor := "DB_Inputs".Sensors["cInBG3007"]); + // in Separator 1 (ILS-KR-M4204) + #fbSensorInput(stInSensorHW := "BG3010", + nInSensorNo := "cInBG3010", + stInOutSensor := "DB_Inputs".Sensors["cInBG3010"]); + // MT in Position (ILS-CV M4501)) + #fbSensorInput(stInSensorHW := "BG3011", + nInSensorNo := "cInBG3011", + stInOutSensor := "DB_Inputs".Sensors["cInBG3011"]); + // Stausensor 2 (ILS-KR-M4204) + #fbSensorInput(stInSensorHW := "BG3012", + nInSensorNo := "cInBG3012", + stInOutSensor := "DB_Inputs".Sensors["cInBG3012"]); + // in Separator 2 (ILS-KR-M4204) + #fbSensorInput(stInSensorHW := "BG3013", + nInSensorNo := "cInBG3013", + stInOutSensor := "DB_Inputs".Sensors["cInBG3013"]); + // Stausensor nach Ausfahrt KR-M4204 ( ILS-CV M4203) + #fbSensorInput(stInSensorHW := "BG3014", + nInSensorNo := "cInBG3014", + stInOutSensor := "DB_Inputs".Sensors["cInBG3014"]); + // Stausensor 1 (ILS-KR-M4204) + #fbSensorInput(stInSensorHW := "BG3015", + nInSensorNo := "cInBG3015", + stInOutSensor := "DB_Inputs".Sensors["cInBG3015"]); + // Stausensor (ILS-KR-M4204) + #fbSensorInput(stInSensorHW := "BG3016", + nInSensorNo := "cInBG3016", + stInOutSensor := "DB_Inputs".Sensors["cInBG3016"]); + // Staumelder, Einfahrt (ILS-CV M4501) + #fbSensorInput(stInSensorHW := "BG3017", + nInSensorNo := "cInBG3017", + stInOutSensor := "DB_Inputs".Sensors["cInBG3017"]); + // in Separator 1 (ILS-CV M4501) + #fbSensorInput(stInSensorHW := "BG3020", + nInSensorNo := "cInBG3020", + stInOutSensor := "DB_Inputs".Sensors["cInBG3020"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4501) + #fbSensorInput(stInSensorHW := "BG3021", + nInSensorNo := "cInBG3021", + stInOutSensor := "DB_Inputs".Sensors["cInBG3021"]); + // Stausensor 1 (ILS-CV M4501) + #fbSensorInput(stInSensorHW := "BG3022", + nInSensorNo := "cInBG3022", + stInOutSensor := "DB_Inputs".Sensors["cInBG3022"]); + // Sensor (ILS-CV M4501) + #fbSensorInput(stInSensorHW := "BG3023", + nInSensorNo := "cInBG3023", + stInOutSensor := "DB_Inputs".Sensors["cInBG3023"]); + // in Separator 1 (ILS-CV M4203) + #fbSensorInput(stInSensorHW := "BG3024", + nInSensorNo := "cInBG3024", + stInOutSensor := "DB_Inputs".Sensors["cInBG3024"]); + // in Separator (ILS-CV M4104) + #fbSensorInput(stInSensorHW := "BG3025", + nInSensorNo := "cInBG3025", + stInOutSensor := "DB_Inputs".Sensors["cInBG3025"]); + // MT in Position (ILS-CV M4104) + #fbSensorInput(stInSensorHW := "BG3026", + nInSensorNo := "cInBG3026", + stInOutSensor := "DB_Inputs".Sensors["cInBG3026"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4104) + #fbSensorInput(stInSensorHW := "BG3027", + nInSensorNo := "cInBG3027", + stInOutSensor := "DB_Inputs".Sensors["cInBG3027"]); + // in Separator 1 (ILS-CV M4503) + #fbSensorInput(stInSensorHW := "BG3060", + nInSensorNo := "cInBG3060", + stInOutSensor := "DB_Inputs".Sensors["cInBG3060"]); + // Stausensor (ILS-CV M4503) + #fbSensorInput(stInSensorHW := "BG3061", + nInSensorNo := "cInBG3061", + stInOutSensor := "DB_Inputs".Sensors["cInBG3061"]); + // Sensor (ILS-CV M4503) + #fbSensorInput(stInSensorHW := "BG3062", + nInSensorNo := "cInBG3062", + stInOutSensor := "DB_Inputs".Sensors["cInBG3062"]); + // in Separator 1 (ILS-CV M4502) + #fbSensorInput(stInSensorHW := "BG3063", + nInSensorNo := "cInBG3063", + stInOutSensor := "DB_Inputs".Sensors["cInBG3063"]); + // MT in Position (ILS-CV M4502)) + #fbSensorInput(stInSensorHW := "BG3064", + nInSensorNo := "cInBG3064", + stInOutSensor := "DB_Inputs".Sensors["cInBG3064"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4502) + #fbSensorInput(stInSensorHW := "BG3065", + nInSensorNo := "cInBG3065", + stInOutSensor := "DB_Inputs".Sensors["cInBG3065"]); + // Sensor Förderer voll (ILS-CV M4502) + #fbSensorInput(stInSensorHW := "BG3066", + nInSensorNo := "cInBG3066", + stInOutSensor := "DB_Inputs".Sensors["cInBG3066"]); + // Stausensor 1 (ILS-CV M4502) + #fbSensorInput(stInSensorHW := "BG3067", + nInSensorNo := "cInBG3067", + stInOutSensor := "DB_Inputs".Sensors["cInBG3067"]); + // Sensor (ILS-CV M4403) + #fbSensorInput(stInSensorHW := "BG3070", + nInSensorNo := "cInBG3070", + stInOutSensor := "DB_Inputs".Sensors["cInBG3070"]); + // Stausensor 1 (ILS-CV M4403) + #fbSensorInput(stInSensorHW := "BG3071", + nInSensorNo := "cInBG3071", + stInOutSensor := "DB_Inputs".Sensors["cInBG3071"]); + // in Separator 2 (ILS-CV M4403) + #fbSensorInput(stInSensorHW := "BG3073", + nInSensorNo := "cInBG3073", + stInOutSensor := "DB_Inputs".Sensors["cInBG3073"]); + // MT in Position (ILS-CV M4403) + #fbSensorInput(stInSensorHW := "BG3074", + nInSensorNo := "cInBG3074", + stInOutSensor := "DB_Inputs".Sensors["cInBG3074"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4403) + #fbSensorInput(stInSensorHW := "BG3075", + nInSensorNo := "cInBG3075", + stInOutSensor := "DB_Inputs".Sensors["cInBG3075"]); + // in Separator 2 (ILS-CV M4503) + #fbSensorInput(stInSensorHW := "BG3080", + nInSensorNo := "cInBG3080", + stInOutSensor := "DB_Inputs".Sensors["cInBG3080"]); + // Abfrage Mitnehmerfinger in Position in Separator 2 (ILS-CV M4503) + #fbSensorInput(stInSensorHW := "BG3081", + nInSensorNo := "cInBG3081", + stInOutSensor := "DB_Inputs".Sensors["cInBG3081"]); + // MT in Position (ILS-CV M4503) + #fbSensorInput(stInSensorHW := "BG3082", + nInSensorNo := "cInBG3082", + stInOutSensor := "DB_Inputs".Sensors["cInBG3082"]); + // in Separator (ILS-CV M4203_A) + #fbSensorInput(stInSensorHW := "BG3120", + nInSensorNo := "cInBG3120", + stInOutSensor := "DB_Inputs".Sensors["cInBG3120"]); + // MT in Position (ILS-CV M4203_A) + #fbSensorInput(stInSensorHW := "BG3121", + nInSensorNo := "cInBG3121", + stInOutSensor := "DB_Inputs".Sensors["cInBG3121"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4302_A) + #fbSensorInput(stInSensorHW := "BG3122", + nInSensorNo := "cInBG3122", + stInOutSensor := "DB_Inputs".Sensors["cInBG3122"]); + // Sensor (ILS-CV M4203_A) + #fbSensorInput(stInSensorHW := "BG3123", + nInSensorNo := "cInBG3123", + stInOutSensor := "DB_Inputs".Sensors["cInBG3123"]); + // Stausensor (ILS-CV M4203_A) + #fbSensorInput(stInSensorHW := "BG3124", + nInSensorNo := "cInBG3124", + stInOutSensor := "DB_Inputs".Sensors["cInBG3124"]); + // in Separator (ILS-CV M4302) + #fbSensorInput(stInSensorHW := "BG3125", + nInSensorNo := "cInBG3125", + stInOutSensor := "DB_Inputs".Sensors["cInBG3125"]); + // Stausensor (ILS-CV M4302_B) + #fbSensorInput(stInSensorHW := "BG3126", + nInSensorNo := "cInBG3126", + stInOutSensor := "DB_Inputs".Sensors["cInBG3126"]); + // Sensor Förderer voll (ILS-CV M4302_B) + #fbSensorInput(stInSensorHW := "BG3127", + nInSensorNo := "cInBG3127", + stInOutSensor := "DB_Inputs".Sensors["cInBG3127"]); + // in Separator 2 (ILS-CV M4302_B) + #fbSensorInput(stInSensorHW := "BG3130", + nInSensorNo := "cInBG3130", + stInOutSensor := "DB_Inputs".Sensors["cInBG3130"]); + // MT in Position (ILS-CV M4302_B) + #fbSensorInput(stInSensorHW := "BG3131", + nInSensorNo := "cInBG3131", + stInOutSensor := "DB_Inputs".Sensors["cInBG3131"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4302_B) + #fbSensorInput(stInSensorHW := "BG3132", + nInSensorNo := "cInBG3132", + stInOutSensor := "DB_Inputs".Sensors["cInBG3132"]); + // Sensor Förderer voll (ILS-CV M4402_B) + #fbSensorInput(stInSensorHW := "BG3133", + nInSensorNo := "cInBG3133", + stInOutSensor := "DB_Inputs".Sensors["cInBG3133"]); + // Stausensor (ILS-CV M4402_B) + #fbSensorInput(stInSensorHW := "BG3134", + nInSensorNo := "cInBG3134", + stInOutSensor := "DB_Inputs".Sensors["cInBG3134"]); + // in Separator 2 (ILS-CV M4402_B) + #fbSensorInput(stInSensorHW := "BG3135", + nInSensorNo := "cInBG3135", + stInOutSensor := "DB_Inputs".Sensors["cInBG3135"]); + // MT in Position (ILS-CV M4402_B) + #fbSensorInput(stInSensorHW := "BG3136", + nInSensorNo := "cInBG3136", + stInOutSensor := "DB_Inputs".Sensors["cInBG3136"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4402_B) + #fbSensorInput(stInSensorHW := "BG3137", + nInSensorNo := "cInBG3137", + stInOutSensor := "DB_Inputs".Sensors["cInBG3137"]); + // Staumelder, Einfahrt (ILS-CV M4103_A) + #fbSensorInput(stInSensorHW := "BG3140", + nInSensorNo := "cInBG3140", + stInOutSensor := "DB_Inputs".Sensors["cInBG3140"]); + // Sensor Förderer voll (ILS-CV M4103_B) + #fbSensorInput(stInSensorHW := "BG3142", + nInSensorNo := "cInBG3142", + stInOutSensor := "DB_Inputs".Sensors["cInBG3142"]); + // Stausensor (ILS-CV M4103_B) + #fbSensorInput(stInSensorHW := "BG3143", + nInSensorNo := "cInBG3143", + stInOutSensor := "DB_Inputs".Sensors["cInBG3143"]); + // Staumelder, Einfahrt (ILS-CV M4203_A) + #fbSensorInput(stInSensorHW := "BG3144", + nInSensorNo := "cInBG3144", + stInOutSensor := "DB_Inputs".Sensors["cInBG3144"]); + // Sensor Förderer voll (ILS-CV M4203_B) + #fbSensorInput(stInSensorHW := "BG3146", + nInSensorNo := "cInBG3146", + stInOutSensor := "DB_Inputs".Sensors["cInBG3146"]); + // Stausensor (ILS-CV M4203_B) + #fbSensorInput(stInSensorHW := "BG3147", + nInSensorNo := "cInBG3147", + stInOutSensor := "DB_Inputs".Sensors["cInBG3147"]); + // Staumelder, Einfahrt (ILS-CV M4302_A) + #fbSensorInput(stInSensorHW := "BG3150", + nInSensorNo := "cInBG3150", + stInOutSensor := "DB_Inputs".Sensors["cInBG3150"]); + // Sensor Förderer voll (ILS-CV M4302_A) + #fbSensorInput(stInSensorHW := "BG3152", + nInSensorNo := "cInBG3152", + stInOutSensor := "DB_Inputs".Sensors["cInBG3152"]); + // Stausensor (ILS-CV M4302_A) + #fbSensorInput(stInSensorHW := "BG3153", + nInSensorNo := "cInBG3153", + stInOutSensor := "DB_Inputs".Sensors["cInBG3153"]); + // Staumelder, Einfahrt (ILS-CV M4402_A) + #fbSensorInput(stInSensorHW := "BG3154", + nInSensorNo := "cInBG3154", + stInOutSensor := "DB_Inputs".Sensors["cInBG3154"]); + // Sensor Förderer voll (ILS-CV M4402_A) + #fbSensorInput(stInSensorHW := "BG3156", + nInSensorNo := "cInBG3156", + stInOutSensor := "DB_Inputs".Sensors["cInBG3156"]); + // Stausensor (ILS-CV M4402_A) + #fbSensorInput(stInSensorHW := "BG3157", + nInSensorNo := "cInBG3157", + stInOutSensor := "DB_Inputs".Sensors["cInBG3157"]); + // Sensor Förderer voll (ILS-CV M0100) + #fbSensorInput(stInSensorHW := "BG3240", + nInSensorNo := "cInBG3240", + stInOutSensor := "DB_Inputs".Sensors["cInBG3240"]); + // Stausensor (ILS-CV M0100) + #fbSensorInput(stInSensorHW := "BG3241", + nInSensorNo := "cInBG3241", + stInOutSensor := "DB_Inputs".Sensors["cInBG3241"]); + // in Separator 1 (ILS-CV M0100) + #fbSensorInput(stInSensorHW := "BG3242", + nInSensorNo := "cInBG3242", + stInOutSensor := "DB_Inputs".Sensors["cInBG3242"]); + // Stausensor 1 (KR-K0111) + #fbSensorInput(stInSensorHW := "BG3243", + nInSensorNo := "cInBG3243", + stInOutSensor := "DB_Inputs".Sensors["cInBG3243"]); + // Stausensor 2 (KR-K0111) + #fbSensorInput(stInSensorHW := "BG3245", + nInSensorNo := "cInBG3245", + stInOutSensor := "DB_Inputs".Sensors["cInBG3245"]); + // in Separator, Einfahrt MT-Buffer LS2 (KR-M0101) + #fbSensorInput(stInSensorHW := "BG3246", + nInSensorNo := "cInBG3246", + stInOutSensor := "DB_Inputs".Sensors["cInBG3246"]); + // Stausensor Str.01 (Block 1.2) + #fbSensorInput(stInSensorHW := "BG3250", + nInSensorNo := "cInBG3250", + stInOutSensor := "DB_Inputs".Sensors["cInBG3250"]); + // Stausensor Str.02 (Block 1.2) + #fbSensorInput(stInSensorHW := "BG3251", + nInSensorNo := "cInBG3251", + stInOutSensor := "DB_Inputs".Sensors["cInBG3251"]); + // Stausensor Str.03 (Block 1.2) + #fbSensorInput(stInSensorHW := "BG3252", + nInSensorNo := "cInBG3252", + stInOutSensor := "DB_Inputs".Sensors["cInBG3252"]); + // Stausensor Str.04 (Block 1.2) + #fbSensorInput(stInSensorHW := "BG3253", + nInSensorNo := "cInBG3253", + stInOutSensor := "DB_Inputs".Sensors["cInBG3253"]); + // Stausensor Str.05 (Block 1.2) + #fbSensorInput(stInSensorHW := "BG3254", + nInSensorNo := "cInBG3254", + stInOutSensor := "DB_Inputs".Sensors["cInBG3254"]); + // in Separator, Einfahrt MT-Buffer LS1 (KR-M0101) + #fbSensorInput(stInSensorHW := "BG3257", + nInSensorNo := "cInBG3257", + stInOutSensor := "DB_Inputs".Sensors["cInBG3257"]); + // Stausensor Str.01 (Block 1.1) + #fbSensorInput(stInSensorHW := "BG3260", + nInSensorNo := "cInBG3260", + stInOutSensor := "DB_Inputs".Sensors["cInBG3260"]); + // Stausensor Str.02 (Block 1.1) + #fbSensorInput(stInSensorHW := "BG3261", + nInSensorNo := "cInBG3261", + stInOutSensor := "DB_Inputs".Sensors["cInBG3261"]); + // Stausensor Str.03 (Block 1.1) + #fbSensorInput(stInSensorHW := "BG3262", + nInSensorNo := "cInBG3262", + stInOutSensor := "DB_Inputs".Sensors["cInBG3262"]); + // Stausensor Str.04 (Block 1.1) + #fbSensorInput(stInSensorHW := "BG3263", + nInSensorNo := "cInBG3263", + stInOutSensor := "DB_Inputs".Sensors["cInBG3263"]); + // Stausensor Str.05 (Block 1.1) + #fbSensorInput(stInSensorHW := "BG3264", + nInSensorNo := "cInBG3264", + stInOutSensor := "DB_Inputs".Sensors["cInBG3264"]); + // Sensor MT in Scanposition (ILS-CV M0106) + #fbSensorInput(stInSensorHW := "BG3265", + nInSensorNo := "cInBG3265", + stInOutSensor := "DB_Inputs".Sensors["cInBG3265"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV-M0103) + #fbSensorInput(stInSensorHW := "BG3270", + nInSensorNo := "cInBG3270", + stInOutSensor := "DB_Inputs".Sensors["cInBG3270"]); + // in Separator (ILS-CV M0103) + #fbSensorInput(stInSensorHW := "BG3271", + nInSensorNo := "cInBG3271", + stInOutSensor := "DB_Inputs".Sensors["cInBG3271"]); + // MT in Position (ILS-CV M0103) + #fbSensorInput(stInSensorHW := "BG3272", + nInSensorNo := "cInBG3272", + stInOutSensor := "DB_Inputs".Sensors["cInBG3272"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M0106) + #fbSensorInput(stInSensorHW := "BG3273", + nInSensorNo := "cInBG3273", + stInOutSensor := "DB_Inputs".Sensors["cInBG3273"]); + // Stausensor (ILS-CV M0106) + #fbSensorInput(stInSensorHW := "BG3276", + nInSensorNo := "cInBG3276", + stInOutSensor := "DB_Inputs".Sensors["cInBG3276"]); + // in Separator (ILS-BX1104) + #fbSensorInput(stInSensorHW := "BG3280", + nInSensorNo := "cInBG3280", + stInOutSensor := "DB_Inputs".Sensors["cInBG3280"]); + // Stausensor(ILS-BX1104) + #fbSensorInput(stInSensorHW := "BG3281", + nInSensorNo := "cInBG3281", + stInOutSensor := "DB_Inputs".Sensors["cInBG3281"]); + // MT in Position (ILS-CV M0107) + #fbSensorInput(stInSensorHW := "BG3282", + nInSensorNo := "cInBG3282", + stInOutSensor := "DB_Inputs".Sensors["cInBG3282"]); + // in Separator (ILS-CV M0107) + #fbSensorInput(stInSensorHW := "BG3283", + nInSensorNo := "cInBG3283", + stInOutSensor := "DB_Inputs".Sensors["cInBG3283"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M0107) + #fbSensorInput(stInSensorHW := "BG3284", + nInSensorNo := "cInBG3284", + stInOutSensor := "DB_Inputs".Sensors["cInBG3284"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M0110) + #fbSensorInput(stInSensorHW := "BG3285", + nInSensorNo := "cInBG3285", + stInOutSensor := "DB_Inputs".Sensors["cInBG3285"]); + // in Separator 2 (ILS-CV M0100) + #fbSensorInput(stInSensorHW := "BG3290", + nInSensorNo := "cInBG3290", + stInOutSensor := "DB_Inputs".Sensors["cInBG3290"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M0100) + #fbSensorInput(stInSensorHW := "BG3291", + nInSensorNo := "cInBG3291", + stInOutSensor := "DB_Inputs".Sensors["cInBG3291"]); + // MT in Position (ILS-CV M0100) + #fbSensorInput(stInSensorHW := "BG3292", + nInSensorNo := "cInBG3292", + stInOutSensor := "DB_Inputs".Sensors["cInBG3292"]); + // Stausensor (ILS-CV M0110) + #fbSensorInput(stInSensorHW := "BG3294", + nInSensorNo := "cInBG3294", + stInOutSensor := "DB_Inputs".Sensors["cInBG3294"]); + // in Separator (ILS-CV) + #fbSensorInput(stInSensorHW := "BG3295", + nInSensorNo := "cInBG3295", + stInOutSensor := "DB_Inputs".Sensors["cInBG3295"]); + // Stausensor (ILS-CV) + #fbSensorInput(stInSensorHW := "BG3296", + nInSensorNo := "cInBG3296", + stInOutSensor := "DB_Inputs".Sensors["cInBG3296"]); + // Sensor MT in Scanposition (ILS-CV M0110) + #fbSensorInput(stInSensorHW := "BG3297", + nInSensorNo := "cInBG3297", + stInOutSensor := "DB_Inputs".Sensors["cInBG3297"]); + // in Separator 1 (ILS-KR-M0102) + #fbSensorInput(stInSensorHW := "BG3300", + nInSensorNo := "cInBG3300", + stInOutSensor := "DB_Inputs".Sensors["cInBG3300"]); + // Teil auf MT (Sep 1MB3300) + #fbSensorInput(stInSensorHW := "BG3301", + nInSensorNo := "cInBG3301", + stInOutSensor := "DB_Inputs".Sensors["cInBG3301"]); + // Stausensor 2 (ILS-KR-M0102) + #fbSensorInput(stInSensorHW := "BG3304", + nInSensorNo := "cInBG3304", + stInOutSensor := "DB_Inputs".Sensors["cInBG3304"]); + // Stausensor (ILS-CV-M0103) + #fbSensorInput(stInSensorHW := "BG3305", + nInSensorNo := "cInBG3305", + stInOutSensor := "DB_Inputs".Sensors["cInBG3305"]); + // in Separator 2 (ILS-KR-M0102) + #fbSensorInput(stInSensorHW := "BG3306", + nInSensorNo := "cInBG3306", + stInOutSensor := "DB_Inputs".Sensors["cInBG3306"]); + // in Separator 01 (Block 1.1.) + #fbSensorInput(stInSensorHW := "BG3310", + nInSensorNo := "cInBG3310", + stInOutSensor := "DB_Inputs".Sensors["cInBG3310"]); + // in Separator 02 (Block 1.1.) + #fbSensorInput(stInSensorHW := "BG3311", + nInSensorNo := "cInBG3311", + stInOutSensor := "DB_Inputs".Sensors["cInBG3311"]); + // in Separator 03 (Block 1.1.) + #fbSensorInput(stInSensorHW := "BG3312", + nInSensorNo := "cInBG3312", + stInOutSensor := "DB_Inputs".Sensors["cInBG3312"]); + // in Separator 04 (Block 1.1.) + #fbSensorInput(stInSensorHW := "BG3313", + nInSensorNo := "cInBG3313", + stInOutSensor := "DB_Inputs".Sensors["cInBG3313"]); + // in Separator 05 (Block 1.1.) + #fbSensorInput(stInSensorHW := "BG3314", + nInSensorNo := "cInBG3314", + stInOutSensor := "DB_Inputs".Sensors["cInBG3314"]); + // in Separator (Block 1.1) + #fbSensorInput(stInSensorHW := "BG3315", + nInSensorNo := "cInBG3315", + stInOutSensor := "DB_Inputs".Sensors["cInBG3315"]); + // in Separator, (KR-M0102) + #fbSensorInput(stInSensorHW := "BG3316", + nInSensorNo := "cInBG3316", + stInOutSensor := "DB_Inputs".Sensors["cInBG3316"]); + // in Separator 01 (Block 1.2.) + #fbSensorInput(stInSensorHW := "BG3320", + nInSensorNo := "cInBG3320", + stInOutSensor := "DB_Inputs".Sensors["cInBG3320"]); + // in Separator 02 (Block 1.2.) + #fbSensorInput(stInSensorHW := "BG3321", + nInSensorNo := "cInBG3321", + stInOutSensor := "DB_Inputs".Sensors["cInBG3321"]); + // in Separator 03 (Block 1.2) + #fbSensorInput(stInSensorHW := "BG3322", + nInSensorNo := "cInBG3322", + stInOutSensor := "DB_Inputs".Sensors["cInBG3322"]); + // in Separator 04 (Block 1.2) + #fbSensorInput(stInSensorHW := "BG3323", + nInSensorNo := "cInBG3323", + stInOutSensor := "DB_Inputs".Sensors["cInBG3323"]); + // in Separator 05 (Block 1.2) + #fbSensorInput(stInSensorHW := "BG3324", + nInSensorNo := "cInBG3324", + stInOutSensor := "DB_Inputs".Sensors["cInBG3324"]); + // in Separator (Block 1.2.) + #fbSensorInput(stInSensorHW := "BG3325", + nInSensorNo := "cInBG3325", + stInOutSensor := "DB_Inputs".Sensors["cInBG3325"]); + // Stausensor 3 (ILS-KR-M0102) + #fbSensorInput(stInSensorHW := "BG3330", + nInSensorNo := "cInBG3330", + stInOutSensor := "DB_Inputs".Sensors["cInBG3330"]); + // Stausensor1 + #fbSensorInput(stInSensorHW := "BG3331", + nInSensorNo := "cInBG3331", + stInOutSensor := "DB_Inputs".Sensors["cInBG3331"]); + // in Separator 3 (ILS-KR-M0102) + #fbSensorInput(stInSensorHW := "BG3332", + nInSensorNo := "cInBG3332", + stInOutSensor := "DB_Inputs".Sensors["cInBG3332"]); + // Stausensor 4 (ILS-KR-M0102) + #fbSensorInput(stInSensorHW := "BG3334", + nInSensorNo := "cInBG3334", + stInOutSensor := "DB_Inputs".Sensors["cInBG3334"]); + // in Separator 4 (ILS-KR-M0102) + #fbSensorInput(stInSensorHW := "BG3335", + nInSensorNo := "cInBG3335", + stInOutSensor := "DB_Inputs".Sensors["cInBG3335"]); + // in Separator 5 (ILS-KR-M0102) + #fbSensorInput(stInSensorHW := "BG3337", + nInSensorNo := "cInBG3337", + stInOutSensor := "DB_Inputs".Sensors["cInBG3337"]); + // Stausensor (ILS-CV M4104) + #fbSensorInput(stInSensorHW := "BG3340", + nInSensorNo := "cInBG3340", + stInOutSensor := "DB_Inputs".Sensors["cInBG3340"]); + // Stausensor 5 (ILS-KR-M0102) + #fbSensorInput(stInSensorHW := "BG3341", + nInSensorNo := "cInBG3341", + stInOutSensor := "DB_Inputs".Sensors["cInBG3341"]); + // Rad dreht (ILS-KR-M0102) + #fbSensorInput(stInSensorHW := "BG3342", + nInSensorNo := "cInBG3342", + stInOutSensor := "DB_Inputs".Sensors["cInBG3342"]); + // LS Endlage ausgefahren + #fbSensorInput(stInSensorHW := "BG3343", + nInSensorNo := "cInBG3343", + stInOutSensor := "DB_Inputs".Sensors["cInBG3343"]); + // LS Endlage eingefahren + #fbSensorInput(stInSensorHW := "BG3344", + nInSensorNo := "cInBG3344", + stInOutSensor := "DB_Inputs".Sensors["cInBG3344"]); + // LS Endlage ausgefahren + #fbSensorInput(stInSensorHW := "BG3345", + nInSensorNo := "cInBG3345", + stInOutSensor := "DB_Inputs".Sensors["cInBG3345"]); + // LS Endlage eingefahren + #fbSensorInput(stInSensorHW := "BG3346", + nInSensorNo := "cInBG3346", + stInOutSensor := "DB_Inputs".Sensors["cInBG3346"]); + // Rad dreht (KR-M0101) + #fbSensorInput(stInSensorHW := "BG3347", + nInSensorNo := "cInBG3347", + stInOutSensor := "DB_Inputs".Sensors["cInBG3347"]); + // Längenabfrage Grenze kurz (ILS-CV) + #fbSensorInput(stInSensorHW := "BG3354", + nInSensorNo := "cInBG3354", + stInOutSensor := "DB_Inputs".Sensors["cInBG3354"]); + // Längenabfrage Grenze lang (ILS-CV) + #fbSensorInput(stInSensorHW := "BG3355", + nInSensorNo := "cInBG3355", + stInOutSensor := "DB_Inputs".Sensors["cInBG3355"]); + // Längenabfrage Grenze zu lang (ILS-CV) + #fbSensorInput(stInSensorHW := "BG3356", + nInSensorNo := "cInBG3356", + stInOutSensor := "DB_Inputs".Sensors["cInBG3356"]); + // Verlassensensor Längenmessung (ILS-CV) + #fbSensorInput(stInSensorHW := "BG3357", + nInSensorNo := "cInBG3357", + stInOutSensor := "DB_Inputs".Sensors["cInBG3357"]); + // Neigungssensor Ladeschleife 1 + #fbSensorInput(stInSensorHW := "BG4740", + nInSensorNo := "cInBG4740", + stInOutSensor := "DB_Inputs".Sensors["cInBG4740"]); + // Bodenabstandssensor ( LS 1) + #fbSensorInput(stInSensorHW := "BG4820", + nInSensorNo := "cInBG4820", + stInOutSensor := "DB_Inputs".Sensors["cInBG4820"]); + // Neigungssensor Ladeschleife 2 + #fbSensorInput(stInSensorHW := "BG5060", + nInSensorNo := "cInBG5060", + stInOutSensor := "DB_Inputs".Sensors["cInBG5060"]); + // Bodenabstandssensor ( LS 2) + #fbSensorInput(stInSensorHW := "BG5140", + nInSensorNo := "cInBG5140", + stInOutSensor := "DB_Inputs".Sensors["cInBG5140"]); +END_FUNCTION_BLOCK diff --git a/results/FB_CallSensors_skel_UH02.scl b/results/FB_CallSensors_skel_UH02.scl new file mode 100644 index 0000000..a04476b --- /dev/null +++ b/results/FB_CallSensors_skel_UH02.scl @@ -0,0 +1,3706 @@ +FUNCTION_BLOCK "FB_CallSensors_skel_UH02" +{ S7_Optimized_Access := 'TRUE' } +VERSION : 0.1 +// AUTOMATISCH GENERIERT — create_skel.py (924 Sensoren) + VAR + fbSensorInput : "FB_SensorInput"; + END_VAR + +BEGIN + // DT Anlage Aus + #fbSensorInput(stInSensorHW := "SF0000", + nInSensorNo := "cInSF0000", + stInOutSensor := "DB_Inputs".Sensors["cInSF0000"]); + // LDT Anlage Ein + #fbSensorInput(stInSensorHW := "SF0001", + nInSensorNo := "cInSF0001", + stInOutSensor := "DB_Inputs".Sensors["cInSF0001"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0002", + nInSensorNo := "cInSF0002", + stInOutSensor := "DB_Inputs".Sensors["cInSF0002"]); + // DT Lampentest + #fbSensorInput(stInSensorHW := "SF0003", + nInSensorNo := "cInSF0003", + stInOutSensor := "DB_Inputs".Sensors["cInSF0003"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0004", + nInSensorNo := "cInBP0004", + stInOutSensor := "DB_Inputs".Sensors["cInBP0004"]); + // Phasenausfall 400V + #fbSensorInput(stInSensorHW := "DI0005", + nInSensorNo := "cInDI0005", + stInOutSensor := "DB_Inputs".Sensors["cInDI0005"]); + // Vorsicherung 400V UC021 + #fbSensorInput(stInSensorHW := "DI0006", + nInSensorNo := "cInDI0006", + stInOutSensor := "DB_Inputs".Sensors["cInDI0006"]); + // Vorsicherung 400V UC022 + #fbSensorInput(stInSensorHW := "DI0007", + nInSensorNo := "cInDI0007", + stInOutSensor := "DB_Inputs".Sensors["cInDI0007"]); + // Vorsicherung 400V UC023 + #fbSensorInput(stInSensorHW := "DI0010", + nInSensorNo := "cInDI0010", + stInOutSensor := "DB_Inputs".Sensors["cInDI0010"]); + // Vorsicherung 400V UC Reserve + #fbSensorInput(stInSensorHW := "DI0011", + nInSensorNo := "cInDI0011", + stInOutSensor := "DB_Inputs".Sensors["cInDI0011"]); + // Vorsicherung 400V UC Reserve + #fbSensorInput(stInSensorHW := "DI0012", + nInSensorNo := "cInDI0012", + stInOutSensor := "DB_Inputs".Sensors["cInDI0012"]); + // Feedback Hauptschütze aktiv + #fbSensorInput(stInSensorHW := "DI0013", + nInSensorNo := "cInDI0013", + stInOutSensor := "DB_Inputs".Sensors["cInDI0013"]); + // Feedback Koppelrelais E-Stop-IF UH03 (QA0660/QA0661) + #fbSensorInput(stInSensorHW := "DI0014", + nInSensorNo := "cInDI0014", + stInOutSensor := "DB_Inputs".Sensors["cInDI0014"]); + // Feedback Koppelrelais E-Stop-IF + #fbSensorInput(stInSensorHW := "DI0015", + nInSensorNo := "cInDI0015", + stInOutSensor := "DB_Inputs".Sensors["cInDI0015"]); + // Sicherungsautomatenfall + #fbSensorInput(stInSensorHW := "DI0016", + nInSensorNo := "cInDI0016", + stInOutSensor := "DB_Inputs".Sensors["cInDI0016"]); + // Vorsicherung 24V OK (FC021) + #fbSensorInput(stInSensorHW := "DI0021", + nInSensorNo := "cInDI0021", + stInOutSensor := "DB_Inputs".Sensors["cInDI0021"]); + // Vorsicherung 24V OK (FC022) + #fbSensorInput(stInSensorHW := "DI0022", + nInSensorNo := "cInDI0022", + stInOutSensor := "DB_Inputs".Sensors["cInDI0022"]); + // Vorsicherung 24V OK (FC023) + #fbSensorInput(stInSensorHW := "DI0023", + nInSensorNo := "cInDI0023", + stInOutSensor := "DB_Inputs".Sensors["cInDI0023"]); + // Vorsicherung 24V OK (FC024) + #fbSensorInput(stInSensorHW := "DI0024", + nInSensorNo := "cInDI0024", + stInOutSensor := "DB_Inputs".Sensors["cInDI0024"]); + // Vorsicherung 24V OK (FC025) + #fbSensorInput(stInSensorHW := "DI0025", + nInSensorNo := "cInDI0025", + stInOutSensor := "DB_Inputs".Sensors["cInDI0025"]); + // Vorsicherung 24V OK (FC026) + #fbSensorInput(stInSensorHW := "DI0026", + nInSensorNo := "cInDI0026", + stInOutSensor := "DB_Inputs".Sensors["cInDI0026"]); + // IF BMZ "fire alarm" + #fbSensorInput(stInSensorHW := "DI0034", + nInSensorNo := "cInDI0034", + stInOutSensor := "DB_Inputs".Sensors["cInDI0034"]); + // IF BST "No fire alarm" + #fbSensorInput(stInSensorHW := "DI0035", + nInSensorNo := "cInDI0035", + stInOutSensor := "DB_Inputs".Sensors["cInDI0035"]); + // IF BST "Non fault" + #fbSensorInput(stInSensorHW := "DI0036", + nInSensorNo := "cInDI0036", + stInOutSensor := "DB_Inputs".Sensors["cInDI0036"]); + // IF BST "FPC opened" + #fbSensorInput(stInSensorHW := "DI0037", + nInSensorNo := "cInDI0037", + stInOutSensor := "DB_Inputs".Sensors["cInDI0037"]); + // Bereichshalt UZ0201 + #fbSensorInput(stInSensorHW := "SF0040", + nInSensorNo := "cInSF0040", + stInOutSensor := "DB_Inputs".Sensors["cInSF0040"]); + // Reset UZ0201 + #fbSensorInput(stInSensorHW := "SF0041", + nInSensorNo := "cInSF0041", + stInOutSensor := "DB_Inputs".Sensors["cInSF0041"]); + // Bereichshalt UZ0202 + #fbSensorInput(stInSensorHW := "SF0042", + nInSensorNo := "cInSF0042", + stInOutSensor := "DB_Inputs".Sensors["cInSF0042"]); + // Reset UZ0202 + #fbSensorInput(stInSensorHW := "SF0043", + nInSensorNo := "cInSF0043", + stInOutSensor := "DB_Inputs".Sensors["cInSF0043"]); + // Bereichshalt UZ0203 + #fbSensorInput(stInSensorHW := "SF0044", + nInSensorNo := "cInSF0044", + stInOutSensor := "DB_Inputs".Sensors["cInSF0044"]); + // Reset UZ0203 + #fbSensorInput(stInSensorHW := "SF0045", + nInSensorNo := "cInSF0045", + stInOutSensor := "DB_Inputs".Sensors["cInSF0045"]); + // Bereichshalt UZ0204 + #fbSensorInput(stInSensorHW := "SF0046", + nInSensorNo := "cInSF0046", + stInOutSensor := "DB_Inputs".Sensors["cInSF0046"]); + // Reset UZ0204 + #fbSensorInput(stInSensorHW := "SF0047", + nInSensorNo := "cInSF0047", + stInOutSensor := "DB_Inputs".Sensors["cInSF0047"]); + // Bereichshalt UZ0205 + #fbSensorInput(stInSensorHW := "SF0050", + nInSensorNo := "cInSF0050", + stInOutSensor := "DB_Inputs".Sensors["cInSF0050"]); + // Reset UZ0205 + #fbSensorInput(stInSensorHW := "SF0051", + nInSensorNo := "cInSF0051", + stInOutSensor := "DB_Inputs".Sensors["cInSF0051"]); + // Bereichshalt UZ0206 + #fbSensorInput(stInSensorHW := "SF0052", + nInSensorNo := "cInSF0052", + stInOutSensor := "DB_Inputs".Sensors["cInSF0052"]); + // Reset UZ0206 + #fbSensorInput(stInSensorHW := "SF0053", + nInSensorNo := "cInSF0053", + stInOutSensor := "DB_Inputs".Sensors["cInSF0053"]); + // Bereichshalt UZ0207 + #fbSensorInput(stInSensorHW := "SF0054", + nInSensorNo := "cInSF0054", + stInOutSensor := "DB_Inputs".Sensors["cInSF0054"]); + // Reset UZ0207 + #fbSensorInput(stInSensorHW := "SF0055", + nInSensorNo := "cInSF0055", + stInOutSensor := "DB_Inputs".Sensors["cInSF0055"]); + // Bereichshalt UZ0208 + #fbSensorInput(stInSensorHW := "SF0056", + nInSensorNo := "cInSF0056", + stInOutSensor := "DB_Inputs".Sensors["cInSF0056"]); + // Reset UZ0208 + #fbSensorInput(stInSensorHW := "SF0057", + nInSensorNo := "cInSF0057", + stInOutSensor := "DB_Inputs".Sensors["cInSF0057"]); + // MSS ausgelöst FC0060 (KR-M1103) + #fbSensorInput(stInSensorHW := "FC0060", + nInSensorNo := "cInFC0060", + stInOutSensor := "DB_Inputs".Sensors["cInFC0060"]); + // MSS ausgelöst FC0061 (KR-M1104) + #fbSensorInput(stInSensorHW := "FC0061", + nInSensorNo := "cInFC0061", + stInOutSensor := "DB_Inputs".Sensors["cInFC0061"]); + // MSS ausgelöst FC0062 (KR-M1201) + #fbSensorInput(stInSensorHW := "FC0062", + nInSensorNo := "cInFC0062", + stInOutSensor := "DB_Inputs".Sensors["cInFC0062"]); + // MSS ausgelöst FC0063 (KR-M1202) + #fbSensorInput(stInSensorHW := "FC0063", + nInSensorNo := "cInFC0063", + stInOutSensor := "DB_Inputs".Sensors["cInFC0063"]); + // MSS ausgelöst FC0064 (CV-M1205) + #fbSensorInput(stInSensorHW := "FC0064", + nInSensorNo := "cInFC0064", + stInOutSensor := "DB_Inputs".Sensors["cInFC0064"]); + // MSS ausgelöst FC0065 (CV-M1206) + #fbSensorInput(stInSensorHW := "FC0065", + nInSensorNo := "cInFC0065", + stInOutSensor := "DB_Inputs".Sensors["cInFC0065"]); + // MSS ausgelöst FC0066 (CV-M1207) + #fbSensorInput(stInSensorHW := "FC0066", + nInSensorNo := "cInFC0066", + stInOutSensor := "DB_Inputs".Sensors["cInFC0066"]); + // MSS ausgelöst FC0067 (CV-M1208) + #fbSensorInput(stInSensorHW := "FC0067", + nInSensorNo := "cInFC0067", + stInOutSensor := "DB_Inputs".Sensors["cInFC0067"]); + // MSS ausgelöst FC0070 (CV-M1209) + #fbSensorInput(stInSensorHW := "FC0070", + nInSensorNo := "cInFC0070", + stInOutSensor := "DB_Inputs".Sensors["cInFC0070"]); + // MSS ausgelöst FC0071 (CV-M1401) + #fbSensorInput(stInSensorHW := "FC0071", + nInSensorNo := "cInFC0071", + stInOutSensor := "DB_Inputs".Sensors["cInFC0071"]); + // MSS ausgelöst FC0072 (CV-M1501) + #fbSensorInput(stInSensorHW := "FC0072", + nInSensorNo := "cInFC0072", + stInOutSensor := "DB_Inputs".Sensors["cInFC0072"]); + // MSS ausgelöst FC0073 (CV-M1601) + #fbSensorInput(stInSensorHW := "FC0073", + nInSensorNo := "cInFC0073", + stInOutSensor := "DB_Inputs".Sensors["cInFC0073"]); + // MSS ausgelöst FC0074 (CV-M4701) + #fbSensorInput(stInSensorHW := "FC0074", + nInSensorNo := "cInFC0074", + stInOutSensor := "DB_Inputs".Sensors["cInFC0074"]); + // MSS ausgelöst FC0075 (KR-M1110) + #fbSensorInput(stInSensorHW := "FC0075", + nInSensorNo := "cInFC0075", + stInOutSensor := "DB_Inputs".Sensors["cInFC0075"]); + // MSS ausgelöst FC0076 (CV-M1801) + #fbSensorInput(stInSensorHW := "FC0076", + nInSensorNo := "cInFC0076", + stInOutSensor := "DB_Inputs".Sensors["cInFC0076"]); + // MSS ausgelöst FC0077 (CV-M1801) + #fbSensorInput(stInSensorHW := "FC0077", + nInSensorNo := "cInFC0077", + stInOutSensor := "DB_Inputs".Sensors["cInFC0077"]); + // Bereichshalt UZ0209 + #fbSensorInput(stInSensorHW := "SF0080", + nInSensorNo := "cInSF0080", + stInOutSensor := "DB_Inputs".Sensors["cInSF0080"]); + // Reset UZ0209 + #fbSensorInput(stInSensorHW := "SF0081", + nInSensorNo := "cInSF0081", + stInOutSensor := "DB_Inputs".Sensors["cInSF0081"]); + // Bereichshalt UZ0210 + #fbSensorInput(stInSensorHW := "SF0082", + nInSensorNo := "cInSF0082", + stInOutSensor := "DB_Inputs".Sensors["cInSF0082"]); + // Reset UZ0210 + #fbSensorInput(stInSensorHW := "SF0083", + nInSensorNo := "cInSF0083", + stInOutSensor := "DB_Inputs".Sensors["cInSF0083"]); + // Bereichshalt UZ0211 + #fbSensorInput(stInSensorHW := "SF0084", + nInSensorNo := "cInSF0084", + stInOutSensor := "DB_Inputs".Sensors["cInSF0084"]); + // Reset UZ0211 + #fbSensorInput(stInSensorHW := "SF0085", + nInSensorNo := "cInSF0085", + stInOutSensor := "DB_Inputs".Sensors["cInSF0085"]); + // Meldekontakt 400V Motor+Bremse + #fbSensorInput(stInSensorHW := "DI0100", + nInSensorNo := "cInDI0100", + stInOutSensor := "DB_Inputs".Sensors["cInDI0100"]); + // Vorsicherung 24V OK (FC101) + #fbSensorInput(stInSensorHW := "DI0101", + nInSensorNo := "cInDI0101", + stInOutSensor := "DB_Inputs".Sensors["cInDI0101"]); + // Vorsicherung 24V OK (FC102) + #fbSensorInput(stInSensorHW := "DI0102", + nInSensorNo := "cInDI0102", + stInOutSensor := "DB_Inputs".Sensors["cInDI0102"]); + // Vorsicherung 24V OK (FC103) + #fbSensorInput(stInSensorHW := "DI0103", + nInSensorNo := "cInDI0103", + stInOutSensor := "DB_Inputs".Sensors["cInDI0103"]); + // Feedback Hauptschütze aktiv (QA0920/QA0921) + #fbSensorInput(stInSensorHW := "DI0106", + nInSensorNo := "cInDI0106", + stInOutSensor := "DB_Inputs".Sensors["cInDI0106"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0107", + nInSensorNo := "cInBP0107", + stInOutSensor := "DB_Inputs".Sensors["cInBP0107"]); + // Feedback Koppelrelais E-Stop-IF (QA0922/QA0923) + #fbSensorInput(stInSensorHW := "DI0114", + nInSensorNo := "cInDI0114", + stInOutSensor := "DB_Inputs".Sensors["cInDI0114"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0117", + nInSensorNo := "cInSF0117", + stInOutSensor := "DB_Inputs".Sensors["cInSF0117"]); + // Bereichshalt UZ2101 + #fbSensorInput(stInSensorHW := "SF0120", + nInSensorNo := "cInSF0120", + stInOutSensor := "DB_Inputs".Sensors["cInSF0120"]); + // Reset UZ2101 + #fbSensorInput(stInSensorHW := "SF0121", + nInSensorNo := "cInSF0121", + stInOutSensor := "DB_Inputs".Sensors["cInSF0121"]); + // Bereichshalt UZ2102 + #fbSensorInput(stInSensorHW := "SF0122", + nInSensorNo := "cInSF0122", + stInOutSensor := "DB_Inputs".Sensors["cInSF0122"]); + // Reset UZ2102 + #fbSensorInput(stInSensorHW := "SF0123", + nInSensorNo := "cInSF0123", + stInOutSensor := "DB_Inputs".Sensors["cInSF0123"]); + // Bereichshalt UZ2103 + #fbSensorInput(stInSensorHW := "SF0124", + nInSensorNo := "cInSF0124", + stInOutSensor := "DB_Inputs".Sensors["cInSF0124"]); + // Reset UZ2103 + #fbSensorInput(stInSensorHW := "SF0125", + nInSensorNo := "cInSF0125", + stInOutSensor := "DB_Inputs".Sensors["cInSF0125"]); + // Bereichshalt UZ2104 + #fbSensorInput(stInSensorHW := "SF0126", + nInSensorNo := "cInSF0126", + stInOutSensor := "DB_Inputs".Sensors["cInSF0126"]); + // Reset UZ2104 + #fbSensorInput(stInSensorHW := "SF0127", + nInSensorNo := "cInSF0127", + stInOutSensor := "DB_Inputs".Sensors["cInSF0127"]); + // MSS ausgelöst FC0140 (KR-M1101) + #fbSensorInput(stInSensorHW := "FC0140", + nInSensorNo := "cInFC0140", + stInOutSensor := "DB_Inputs".Sensors["cInFC0140"]); + // MSS ausgelöst FC0141 (KR-M1102) + #fbSensorInput(stInSensorHW := "FC0141", + nInSensorNo := "cInFC0141", + stInOutSensor := "DB_Inputs".Sensors["cInFC0141"]); + // MSS ausgelöst FC0142 (CV-M1105) + #fbSensorInput(stInSensorHW := "FC0142", + nInSensorNo := "cInFC0142", + stInOutSensor := "DB_Inputs".Sensors["cInFC0142"]); + // MSS ausgelöst FC0143 (CV-M1106) + #fbSensorInput(stInSensorHW := "FC0143", + nInSensorNo := "cInFC0143", + stInOutSensor := "DB_Inputs".Sensors["cInFC0143"]); + // MSS ausgelöst FC0144 (CV-M1107) + #fbSensorInput(stInSensorHW := "FC0144", + nInSensorNo := "cInFC0144", + stInOutSensor := "DB_Inputs".Sensors["cInFC0144"]); + // MSS ausgelöst FC0145 (CV-M1108) + #fbSensorInput(stInSensorHW := "FC0145", + nInSensorNo := "cInFC0145", + stInOutSensor := "DB_Inputs".Sensors["cInFC0145"]); + // MSS ausgelöst FC0146 (CV-M1109) + #fbSensorInput(stInSensorHW := "FC0146", + nInSensorNo := "cInFC0146", + stInOutSensor := "DB_Inputs".Sensors["cInFC0146"]); + // Meldekontakt 400V Motor+Bremse + #fbSensorInput(stInSensorHW := "DI0160", + nInSensorNo := "cInDI0160", + stInOutSensor := "DB_Inputs".Sensors["cInDI0160"]); + // Vorsicherung 24V OK (FC161) + #fbSensorInput(stInSensorHW := "DI0161", + nInSensorNo := "cInDI0161", + stInOutSensor := "DB_Inputs".Sensors["cInDI0161"]); + // Vorsicherung 24V OK (FC162) + #fbSensorInput(stInSensorHW := "DI0162", + nInSensorNo := "cInDI0162", + stInOutSensor := "DB_Inputs".Sensors["cInDI0162"]); + // Vorsicherung 24V OK (FC163) + #fbSensorInput(stInSensorHW := "DI0163", + nInSensorNo := "cInDI0163", + stInOutSensor := "DB_Inputs".Sensors["cInDI0163"]); + // Vorsicherung 24V OK (FC164) + #fbSensorInput(stInSensorHW := "DI0164", + nInSensorNo := "cInDI0164", + stInOutSensor := "DB_Inputs".Sensors["cInDI0164"]); + // Vorsicherung 24V OK (FC165) + #fbSensorInput(stInSensorHW := "DI0165", + nInSensorNo := "cInDI0165", + stInOutSensor := "DB_Inputs".Sensors["cInDI0165"]); + // Feedback Hauptschütze aktiv (QA1230/QA1231) + #fbSensorInput(stInSensorHW := "DI0166", + nInSensorNo := "cInDI0166", + stInOutSensor := "DB_Inputs".Sensors["cInDI0166"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0167", + nInSensorNo := "cInBP0167", + stInOutSensor := "DB_Inputs".Sensors["cInBP0167"]); + // Feedback Koppelrelais E-Stop-IF (QA1232/QA1233) + #fbSensorInput(stInSensorHW := "DI0174", + nInSensorNo := "cInDI0174", + stInOutSensor := "DB_Inputs".Sensors["cInDI0174"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0177", + nInSensorNo := "cInSF0177", + stInOutSensor := "DB_Inputs".Sensors["cInSF0177"]); + // Bereichshalt UZ2201 + #fbSensorInput(stInSensorHW := "SF0180", + nInSensorNo := "cInSF0180", + stInOutSensor := "DB_Inputs".Sensors["cInSF0180"]); + // Reset UZ2201 + #fbSensorInput(stInSensorHW := "SF0181", + nInSensorNo := "cInSF0181", + stInOutSensor := "DB_Inputs".Sensors["cInSF0181"]); + // Bereichshalt UZ2202 + #fbSensorInput(stInSensorHW := "SF0182", + nInSensorNo := "cInSF0182", + stInOutSensor := "DB_Inputs".Sensors["cInSF0182"]); + // Reset UZ2202 + #fbSensorInput(stInSensorHW := "SF0183", + nInSensorNo := "cInSF0183", + stInOutSensor := "DB_Inputs".Sensors["cInSF0183"]); + // Bereichshalt UZ2203 + #fbSensorInput(stInSensorHW := "SF0184", + nInSensorNo := "cInSF0184", + stInOutSensor := "DB_Inputs".Sensors["cInSF0184"]); + // Reset UZ2203 + #fbSensorInput(stInSensorHW := "SF0185", + nInSensorNo := "cInSF0185", + stInOutSensor := "DB_Inputs".Sensors["cInSF0185"]); + // Bereichshalt UZ2204 + #fbSensorInput(stInSensorHW := "SF0186", + nInSensorNo := "cInSF0186", + stInOutSensor := "DB_Inputs".Sensors["cInSF0186"]); + // Reset UZ2204 + #fbSensorInput(stInSensorHW := "SF0187", + nInSensorNo := "cInSF0187", + stInOutSensor := "DB_Inputs".Sensors["cInSF0187"]); + // Bereichshalt UZ2205 + #fbSensorInput(stInSensorHW := "SF0190", + nInSensorNo := "cInSF0190", + stInOutSensor := "DB_Inputs".Sensors["cInSF0190"]); + // Reset UZ2205 + #fbSensorInput(stInSensorHW := "SF0191", + nInSensorNo := "cInSF0191", + stInOutSensor := "DB_Inputs".Sensors["cInSF0191"]); + // Bereichshalt UZ2206 + #fbSensorInput(stInSensorHW := "SF0192", + nInSensorNo := "cInSF0192", + stInOutSensor := "DB_Inputs".Sensors["cInSF0192"]); + // Reset UZ2206 + #fbSensorInput(stInSensorHW := "SF0193", + nInSensorNo := "cInSF0193", + stInOutSensor := "DB_Inputs".Sensors["cInSF0193"]); + // Bereichshalt UZ2207 + #fbSensorInput(stInSensorHW := "SF0194", + nInSensorNo := "cInSF0194", + stInOutSensor := "DB_Inputs".Sensors["cInSF0194"]); + // Reset UZ2207 + #fbSensorInput(stInSensorHW := "SF0195", + nInSensorNo := "cInSF0195", + stInOutSensor := "DB_Inputs".Sensors["cInSF0195"]); + // Bereichshalt UZ2208 + #fbSensorInput(stInSensorHW := "SF0196", + nInSensorNo := "cInSF0196", + stInOutSensor := "DB_Inputs".Sensors["cInSF0196"]); + // Reset UZ2208 + #fbSensorInput(stInSensorHW := "SF0197", + nInSensorNo := "cInSF0197", + stInOutSensor := "DB_Inputs".Sensors["cInSF0197"]); + // MSS ausgelöst FC0200 (KR-M1203) + #fbSensorInput(stInSensorHW := "FC0200", + nInSensorNo := "cInFC0200", + stInOutSensor := "DB_Inputs".Sensors["cInFC0200"]); + // MSS ausgelöst FC0201 (KR-M1204) + #fbSensorInput(stInSensorHW := "FC0201", + nInSensorNo := "cInFC0201", + stInOutSensor := "DB_Inputs".Sensors["cInFC0201"]); + // MSS ausgelöst FC0202 (KR-M1301) + #fbSensorInput(stInSensorHW := "FC0202", + nInSensorNo := "cInFC0202", + stInOutSensor := "DB_Inputs".Sensors["cInFC0202"]); + // MSS ausgelöst FC0203 (KR-M1302) + #fbSensorInput(stInSensorHW := "FC0203", + nInSensorNo := "cInFC0203", + stInOutSensor := "DB_Inputs".Sensors["cInFC0203"]); + // Meldekontakt 400V Motor+Bremse + #fbSensorInput(stInSensorHW := "DI0220", + nInSensorNo := "cInDI0220", + stInOutSensor := "DB_Inputs".Sensors["cInDI0220"]); + // Vorsicherung 24V OK (FC221) + #fbSensorInput(stInSensorHW := "DI0221", + nInSensorNo := "cInDI0221", + stInOutSensor := "DB_Inputs".Sensors["cInDI0221"]); + // Vorsicherung 24V OK (FC222) + #fbSensorInput(stInSensorHW := "DI0222", + nInSensorNo := "cInDI0222", + stInOutSensor := "DB_Inputs".Sensors["cInDI0222"]); + // Vorsicherung 24V OK (FC223) + #fbSensorInput(stInSensorHW := "DI0223", + nInSensorNo := "cInDI0223", + stInOutSensor := "DB_Inputs".Sensors["cInDI0223"]); + // Feedback Hauptschütze aktiv (QA1540/QA1541) + #fbSensorInput(stInSensorHW := "DI0226", + nInSensorNo := "cInDI0226", + stInOutSensor := "DB_Inputs".Sensors["cInDI0226"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0227", + nInSensorNo := "cInBP0227", + stInOutSensor := "DB_Inputs".Sensors["cInBP0227"]); + // Feedback Koppelrelais E-Stop-IF (QA1542/QA1531) + #fbSensorInput(stInSensorHW := "DI0234", + nInSensorNo := "cInDI0234", + stInOutSensor := "DB_Inputs".Sensors["cInDI0234"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0237", + nInSensorNo := "cInSF0237", + stInOutSensor := "DB_Inputs".Sensors["cInSF0237"]); + // Bereichshalt UZ2301 + #fbSensorInput(stInSensorHW := "SF0240", + nInSensorNo := "cInSF0240", + stInOutSensor := "DB_Inputs".Sensors["cInSF0240"]); + // Reset UZ2301 + #fbSensorInput(stInSensorHW := "SF0241", + nInSensorNo := "cInSF0241", + stInOutSensor := "DB_Inputs".Sensors["cInSF0241"]); + // Bereichshalt UZ2302 + #fbSensorInput(stInSensorHW := "SF0242", + nInSensorNo := "cInSF0242", + stInOutSensor := "DB_Inputs".Sensors["cInSF0242"]); + // Reset UZ2302 + #fbSensorInput(stInSensorHW := "SF0243", + nInSensorNo := "cInSF0243", + stInOutSensor := "DB_Inputs".Sensors["cInSF0243"]); + // Bereichshalt UZ2303 + #fbSensorInput(stInSensorHW := "SF0244", + nInSensorNo := "cInSF0244", + stInOutSensor := "DB_Inputs".Sensors["cInSF0244"]); + // Reset UZ2303 + #fbSensorInput(stInSensorHW := "SF0245", + nInSensorNo := "cInSF0245", + stInOutSensor := "DB_Inputs".Sensors["cInSF0245"]); + // Bereichshalt UZ2304 + #fbSensorInput(stInSensorHW := "SF0246", + nInSensorNo := "cInSF0246", + stInOutSensor := "DB_Inputs".Sensors["cInSF0246"]); + // Reset UZ2304 + #fbSensorInput(stInSensorHW := "SF0247", + nInSensorNo := "cInSF0247", + stInOutSensor := "DB_Inputs".Sensors["cInSF0247"]); + // MSS ausgelöst FC0260 (KR-M1303) + #fbSensorInput(stInSensorHW := "FC0260", + nInSensorNo := "cInFC0260", + stInOutSensor := "DB_Inputs".Sensors["cInFC0260"]); + // MSS ausgelöst FC0261 (KR-M1304) + #fbSensorInput(stInSensorHW := "FC0261", + nInSensorNo := "cInFC0261", + stInOutSensor := "DB_Inputs".Sensors["cInFC0261"]); + // MSS ausgelöst FC0262 (CV-M1305) + #fbSensorInput(stInSensorHW := "FC0262", + nInSensorNo := "cInFC0262", + stInOutSensor := "DB_Inputs".Sensors["cInFC0262"]); + // MSS ausgelöst FC0263 (CV-M1306) + #fbSensorInput(stInSensorHW := "FC0263", + nInSensorNo := "cInFC0263", + stInOutSensor := "DB_Inputs".Sensors["cInFC0263"]); + // MSS ausgelöst FC0264 (CV-M1307) + #fbSensorInput(stInSensorHW := "FC0264", + nInSensorNo := "cInFC0264", + stInOutSensor := "DB_Inputs".Sensors["cInFC0264"]); + // MSS ausgelöst FC0265 (CV-M1308) + #fbSensorInput(stInSensorHW := "FC0265", + nInSensorNo := "cInFC0265", + stInOutSensor := "DB_Inputs".Sensors["cInFC0265"]); + // MSS ausgelöst FC0266 (CV-M1309) + #fbSensorInput(stInSensorHW := "FC0266", + nInSensorNo := "cInFC0266", + stInOutSensor := "DB_Inputs".Sensors["cInFC0266"]); + // Not Halt Kanal 1 UH02 + #fbSensorInput(stInSensorHW := "SF0400", + nInSensorNo := "cInSF0400", + stInOutSensor := "DB_Inputs".Sensors["cInSF0400"]); + // Not Halt Kanal 1 UZ0201 + #fbSensorInput(stInSensorHW := "SF0401", + nInSensorNo := "cInSF0401", + stInOutSensor := "DB_Inputs".Sensors["cInSF0401"]); + // Not Halt Kanal 1 UZ0202 + #fbSensorInput(stInSensorHW := "SF0402", + nInSensorNo := "cInSF0402", + stInOutSensor := "DB_Inputs".Sensors["cInSF0402"]); + // Not Halt Kanal 1 UZ0203 + #fbSensorInput(stInSensorHW := "SF0403", + nInSensorNo := "cInSF0403", + stInOutSensor := "DB_Inputs".Sensors["cInSF0403"]); + // Not Halt Kanal 2 UH02 + #fbSensorInput(stInSensorHW := "SF0404", + nInSensorNo := "cInSF0404", + stInOutSensor := "DB_Inputs".Sensors["cInSF0404"]); + // Not Halt Kanal 2 UZ0201 + #fbSensorInput(stInSensorHW := "SF0405", + nInSensorNo := "cInSF0405", + stInOutSensor := "DB_Inputs".Sensors["cInSF0405"]); + // Not Halt Kanal 2 UZ0202 + #fbSensorInput(stInSensorHW := "SF0406", + nInSensorNo := "cInSF0406", + stInOutSensor := "DB_Inputs".Sensors["cInSF0406"]); + // Not Halt Kanal 2 UZ0203 + #fbSensorInput(stInSensorHW := "SF0407", + nInSensorNo := "cInSF0407", + stInOutSensor := "DB_Inputs".Sensors["cInSF0407"]); + // Not Halt Kanal 1 UZ0204 + #fbSensorInput(stInSensorHW := "SF0470", + nInSensorNo := "cInSF0470", + stInOutSensor := "DB_Inputs".Sensors["cInSF0470"]); + // Not Halt Kanal 1 UZ0209 + #fbSensorInput(stInSensorHW := "SF0471", + nInSensorNo := "cInSF0471", + stInOutSensor := "DB_Inputs".Sensors["cInSF0471"]); + // Not Halt Kanal 1 UZ0210 + #fbSensorInput(stInSensorHW := "SF0472", + nInSensorNo := "cInSF0472", + stInOutSensor := "DB_Inputs".Sensors["cInSF0472"]); + // Not Halt Kanal 1 UZ0211 + #fbSensorInput(stInSensorHW := "SF0473", + nInSensorNo := "cInSF0473", + stInOutSensor := "DB_Inputs".Sensors["cInSF0473"]); + // Not Halt Kanal 2 UZ0204 + #fbSensorInput(stInSensorHW := "SF0474", + nInSensorNo := "cInSF0474", + stInOutSensor := "DB_Inputs".Sensors["cInSF0474"]); + // Not Halt Kanal 2 UZ0209 + #fbSensorInput(stInSensorHW := "SF0475", + nInSensorNo := "cInSF0475", + stInOutSensor := "DB_Inputs".Sensors["cInSF0475"]); + // Not Halt Kanal 2 UZ0210 + #fbSensorInput(stInSensorHW := "SF0476", + nInSensorNo := "cInSF0476", + stInOutSensor := "DB_Inputs".Sensors["cInSF0476"]); + // Not Halt Kanal 2 UZ0211 + #fbSensorInput(stInSensorHW := "SF0477", + nInSensorNo := "cInSF0477", + stInOutSensor := "DB_Inputs".Sensors["cInSF0477"]); + // Not Halt Schnittstelle CH1 + #fbSensorInput(stInSensorHW := "SF0541", + nInSensorNo := "cInSF0541", + stInOutSensor := "DB_Inputs".Sensors["cInSF0541"]); + // Not Halt Schnittstelle von UH05 CH1 + #fbSensorInput(stInSensorHW := "SF0542", + nInSensorNo := "cInSF0542", + stInOutSensor := "DB_Inputs".Sensors["cInSF0542"]); + // Not Halt Schnittstelle von UH03 CH2 + #fbSensorInput(stInSensorHW := "SF0545", + nInSensorNo := "cInSF0545", + stInOutSensor := "DB_Inputs".Sensors["cInSF0545"]); + // Not Halt Schnittstelle von UH05 CH2 + #fbSensorInput(stInSensorHW := "SF0546", + nInSensorNo := "cInSF0546", + stInOutSensor := "DB_Inputs".Sensors["cInSF0546"]); + // Not Halt Kanal 1 UC021 + #fbSensorInput(stInSensorHW := "SF0710", + nInSensorNo := "cInSF0710", + stInOutSensor := "DB_Inputs".Sensors["cInSF0710"]); + // Not Halt Kanal 1 UZ2101 + #fbSensorInput(stInSensorHW := "SF0711", + nInSensorNo := "cInSF0711", + stInOutSensor := "DB_Inputs".Sensors["cInSF0711"]); + // Not Halt Kanal 1 UZ2102 + #fbSensorInput(stInSensorHW := "SF0712", + nInSensorNo := "cInSF0712", + stInOutSensor := "DB_Inputs".Sensors["cInSF0712"]); + // Not Halt Kanal 1 UZ2103 + #fbSensorInput(stInSensorHW := "SF0713", + nInSensorNo := "cInSF0713", + stInOutSensor := "DB_Inputs".Sensors["cInSF0713"]); + // Not Halt Kanal 2 UC021 + #fbSensorInput(stInSensorHW := "SF0714", + nInSensorNo := "cInSF0714", + stInOutSensor := "DB_Inputs".Sensors["cInSF0714"]); + // Not Halt Kanal 2 UZ2101 + #fbSensorInput(stInSensorHW := "SF0715", + nInSensorNo := "cInSF0715", + stInOutSensor := "DB_Inputs".Sensors["cInSF0715"]); + // Not Halt Kanal 2 UZ2102 + #fbSensorInput(stInSensorHW := "SF0716", + nInSensorNo := "cInSF0716", + stInOutSensor := "DB_Inputs".Sensors["cInSF0716"]); + // Not Halt Kanal 2 UZ2103 + #fbSensorInput(stInSensorHW := "SF0717", + nInSensorNo := "cInSF0717", + stInOutSensor := "DB_Inputs".Sensors["cInSF0717"]); + // Not Halt Kanal 1 UZ2104 + #fbSensorInput(stInSensorHW := "SF0780", + nInSensorNo := "cInSF0780", + stInOutSensor := "DB_Inputs".Sensors["cInSF0780"]); + // Not Halt Schnittstelle CH1 + #fbSensorInput(stInSensorHW := "SF0781", + nInSensorNo := "cInSF0781", + stInOutSensor := "DB_Inputs".Sensors["cInSF0781"]); + // Not Halt Kanal 2 UZ2104 + #fbSensorInput(stInSensorHW := "SF0784", + nInSensorNo := "cInSF0784", + stInOutSensor := "DB_Inputs".Sensors["cInSF0784"]); + // Not Halt Schnittstelle CH2 + #fbSensorInput(stInSensorHW := "SF0785", + nInSensorNo := "cInSF0785", + stInOutSensor := "DB_Inputs".Sensors["cInSF0785"]); + // Not Halt Kanal 1 UC022 + #fbSensorInput(stInSensorHW := "SF1020", + nInSensorNo := "cInSF1020", + stInOutSensor := "DB_Inputs".Sensors["cInSF1020"]); + // Not Halt Kanal 1 UZ2201 + #fbSensorInput(stInSensorHW := "SF1021", + nInSensorNo := "cInSF1021", + stInOutSensor := "DB_Inputs".Sensors["cInSF1021"]); + // Not Halt Kanal 1 UZ2202 + #fbSensorInput(stInSensorHW := "SF1022", + nInSensorNo := "cInSF1022", + stInOutSensor := "DB_Inputs".Sensors["cInSF1022"]); + // Not Halt Kanal 1 UZ2203 + #fbSensorInput(stInSensorHW := "SF1023", + nInSensorNo := "cInSF1023", + stInOutSensor := "DB_Inputs".Sensors["cInSF1023"]); + // Not Halt Kanal 2 UC022 + #fbSensorInput(stInSensorHW := "SF1024", + nInSensorNo := "cInSF1024", + stInOutSensor := "DB_Inputs".Sensors["cInSF1024"]); + // Not Halt Kanal 2 UZ2201 + #fbSensorInput(stInSensorHW := "SF1025", + nInSensorNo := "cInSF1025", + stInOutSensor := "DB_Inputs".Sensors["cInSF1025"]); + // Not Halt Kanal 2 UZ2202 + #fbSensorInput(stInSensorHW := "SF1026", + nInSensorNo := "cInSF1026", + stInOutSensor := "DB_Inputs".Sensors["cInSF1026"]); + // Not Halt Kanal 2 UZ2203 + #fbSensorInput(stInSensorHW := "SF1027", + nInSensorNo := "cInSF1027", + stInOutSensor := "DB_Inputs".Sensors["cInSF1027"]); + // Not Halt Kanal 1 UZ2204 + #fbSensorInput(stInSensorHW := "SF1090", + nInSensorNo := "cInSF1090", + stInOutSensor := "DB_Inputs".Sensors["cInSF1090"]); + // Not Halt Schnittstelle CH1 (UC073-UC022) + #fbSensorInput(stInSensorHW := "SF1091", + nInSensorNo := "cInSF1091", + stInOutSensor := "DB_Inputs".Sensors["cInSF1091"]); + // Not Halt Kanal 2 UZ2204 + #fbSensorInput(stInSensorHW := "SF1094", + nInSensorNo := "cInSF1094", + stInOutSensor := "DB_Inputs".Sensors["cInSF1094"]); + // Not Halt Schnittstelle CH2 (UC073-UC022) + #fbSensorInput(stInSensorHW := "SF1095", + nInSensorNo := "cInSF1095", + stInOutSensor := "DB_Inputs".Sensors["cInSF1095"]); + // Not Halt Kanal 1 UC023 + #fbSensorInput(stInSensorHW := "SF1330", + nInSensorNo := "cInSF1330", + stInOutSensor := "DB_Inputs".Sensors["cInSF1330"]); + // Not Halt Kanal 1 UZ2301 + #fbSensorInput(stInSensorHW := "SF1331", + nInSensorNo := "cInSF1331", + stInOutSensor := "DB_Inputs".Sensors["cInSF1331"]); + // Not Halt Kanal 1 UZ2302 + #fbSensorInput(stInSensorHW := "SF1332", + nInSensorNo := "cInSF1332", + stInOutSensor := "DB_Inputs".Sensors["cInSF1332"]); + // Not Halt Kanal 1 UZ2303 + #fbSensorInput(stInSensorHW := "SF1333", + nInSensorNo := "cInSF1333", + stInOutSensor := "DB_Inputs".Sensors["cInSF1333"]); + // Not Halt Kanal 2 UC023 + #fbSensorInput(stInSensorHW := "SF1334", + nInSensorNo := "cInSF1334", + stInOutSensor := "DB_Inputs".Sensors["cInSF1334"]); + // Not Halt Kanal 2 UZ2301 + #fbSensorInput(stInSensorHW := "SF1335", + nInSensorNo := "cInSF1335", + stInOutSensor := "DB_Inputs".Sensors["cInSF1335"]); + // Not Halt Kanal 2 UZ2302 + #fbSensorInput(stInSensorHW := "SF1336", + nInSensorNo := "cInSF1336", + stInOutSensor := "DB_Inputs".Sensors["cInSF1336"]); + // Not Halt Kanal 2 UZ2303 + #fbSensorInput(stInSensorHW := "SF1337", + nInSensorNo := "cInSF1337", + stInOutSensor := "DB_Inputs".Sensors["cInSF1337"]); + // Not Halt Kanal 1 UZ2304 + #fbSensorInput(stInSensorHW := "SF1400", + nInSensorNo := "cInSF1400", + stInOutSensor := "DB_Inputs".Sensors["cInSF1400"]); + // Not Halt Schnittstelle CH1 + #fbSensorInput(stInSensorHW := "SF1401", + nInSensorNo := "cInSF1401", + stInOutSensor := "DB_Inputs".Sensors["cInSF1401"]); + // Not Halt Kanal 2 UZ2304 + #fbSensorInput(stInSensorHW := "SF1404", + nInSensorNo := "cInSF1404", + stInOutSensor := "DB_Inputs".Sensors["cInSF1404"]); + // Not Halt Schnittstelle CH2 + #fbSensorInput(stInSensorHW := "SF1405", + nInSensorNo := "cInSF1405", + stInOutSensor := "DB_Inputs".Sensors["cInSF1405"]); + // in Separator 2 (ILS-CV M1105) + #fbSensorInput(stInSensorHW := "BG3000", + nInSensorNo := "cInBG3000", + stInOutSensor := "DB_Inputs".Sensors["cInBG3000"]); + // Pin Abfrage (KR-M1101 ) Block 1.1.1 + #fbSensorInput(stInSensorHW := "BG3001", + nInSensorNo := "cInBG3001", + stInOutSensor := "DB_Inputs".Sensors["cInBG3001"]); + // Prüfung MT Pos.1 (KR-K1101 Einfahrt Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3002", + nInSensorNo := "cInBG3002", + stInOutSensor := "DB_Inputs".Sensors["cInBG3002"]); + // Stausensor (KR-M1101 Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3003", + nInSensorNo := "cInBG3003", + stInOutSensor := "DB_Inputs".Sensors["cInBG3003"]); + // in Separator 1 (ILS-CV M1105) + #fbSensorInput(stInSensorHW := "BG3004", + nInSensorNo := "cInBG3004", + stInOutSensor := "DB_Inputs".Sensors["cInBG3004"]); + // Stausensor Str.1 (CV-M1105 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3005", + nInSensorNo := "cInBG3005", + stInOutSensor := "DB_Inputs".Sensors["cInBG3005"]); + // Sensor Förderer voll (ILS-CV M1105) + #fbSensorInput(stInSensorHW := "BG3006", + nInSensorNo := "cInBG3006", + stInOutSensor := "DB_Inputs".Sensors["cInBG3006"]); + // Prüfung MT Pos.2 (KR-K1101 Einfahrt Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3007", + nInSensorNo := "cInBG3007", + stInOutSensor := "DB_Inputs".Sensors["cInBG3007"]); + // Prüfung MT Pos.3 (KR-K1101 Einfahrt Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3010", + nInSensorNo := "cInBG3010", + stInOutSensor := "DB_Inputs".Sensors["cInBG3010"]); + // Prüfung MT Pos.4 (KR-K1101 Einfahrt Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3011", + nInSensorNo := "cInBG3011", + stInOutSensor := "DB_Inputs".Sensors["cInBG3011"]); + // Prüfung MT Pos.5 (KR-K1101 Einfahrt Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3012", + nInSensorNo := "cInBG3012", + stInOutSensor := "DB_Inputs".Sensors["cInBG3012"]); + // Stausensor Str.1 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3030", + nInSensorNo := "cInBG3030", + stInOutSensor := "DB_Inputs".Sensors["cInBG3030"]); + // Stausensor Str.2 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3031", + nInSensorNo := "cInBG3031", + stInOutSensor := "DB_Inputs".Sensors["cInBG3031"]); + // Stausensor Str.3 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3032", + nInSensorNo := "cInBG3032", + stInOutSensor := "DB_Inputs".Sensors["cInBG3032"]); + // Stausensor Str.4 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3033", + nInSensorNo := "cInBG3033", + stInOutSensor := "DB_Inputs".Sensors["cInBG3033"]); + // Stausensor Str.5 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3034", + nInSensorNo := "cInBG3034", + stInOutSensor := "DB_Inputs".Sensors["cInBG3034"]); + // Stausensor Str.6 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3035", + nInSensorNo := "cInBG3035", + stInOutSensor := "DB_Inputs".Sensors["cInBG3035"]); + // Stausensor Str.7 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3036", + nInSensorNo := "cInBG3036", + stInOutSensor := "DB_Inputs".Sensors["cInBG3036"]); + // Stausensor Str.8 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3037", + nInSensorNo := "cInBG3037", + stInOutSensor := "DB_Inputs".Sensors["cInBG3037"]); + // Stausensor Str.9 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3040", + nInSensorNo := "cInBG3040", + stInOutSensor := "DB_Inputs".Sensors["cInBG3040"]); + // Stausensor Str.10 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3041", + nInSensorNo := "cInBG3041", + stInOutSensor := "DB_Inputs".Sensors["cInBG3041"]); + // Stausensor Str.11 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3042", + nInSensorNo := "cInBG3042", + stInOutSensor := "DB_Inputs".Sensors["cInBG3042"]); + // Stausensor Str.12 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3043", + nInSensorNo := "cInBG3043", + stInOutSensor := "DB_Inputs".Sensors["cInBG3043"]); + // Stausensor Str.13 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3044", + nInSensorNo := "cInBG3044", + stInOutSensor := "DB_Inputs".Sensors["cInBG3044"]); + // Stausensor Str.14 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3045", + nInSensorNo := "cInBG3045", + stInOutSensor := "DB_Inputs".Sensors["cInBG3045"]); + // Stausensor Str.15 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3046", + nInSensorNo := "cInBG3046", + stInOutSensor := "DB_Inputs".Sensors["cInBG3046"]); + // Stausensor Str.16 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3047", + nInSensorNo := "cInBG3047", + stInOutSensor := "DB_Inputs".Sensors["cInBG3047"]); + // Stausensor Str.17 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3050", + nInSensorNo := "cInBG3050", + stInOutSensor := "DB_Inputs".Sensors["cInBG3050"]); + // Stausensor Str.18 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3051", + nInSensorNo := "cInBG3051", + stInOutSensor := "DB_Inputs".Sensors["cInBG3051"]); + // Stausensor Str.19 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3052", + nInSensorNo := "cInBG3052", + stInOutSensor := "DB_Inputs".Sensors["cInBG3052"]); + // in Separator 2 (ILS-CV M1106) + #fbSensorInput(stInSensorHW := "BG3060", + nInSensorNo := "cInBG3060", + stInOutSensor := "DB_Inputs".Sensors["cInBG3060"]); + // Pin Abfrage (KR-M1101 ) Block 1.1.2 + #fbSensorInput(stInSensorHW := "BG3061", + nInSensorNo := "cInBG3061", + stInOutSensor := "DB_Inputs".Sensors["cInBG3061"]); + // Prüfung MT Pos.1 (KR-K1101 Einfahrt Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3062", + nInSensorNo := "cInBG3062", + stInOutSensor := "DB_Inputs".Sensors["cInBG3062"]); + // Stausensor Str.2 (KR-M1101) + #fbSensorInput(stInSensorHW := "BG3063", + nInSensorNo := "cInBG3063", + stInOutSensor := "DB_Inputs".Sensors["cInBG3063"]); + // in Separator 1 (ILS-CV M1106) + #fbSensorInput(stInSensorHW := "BG3064", + nInSensorNo := "cInBG3064", + stInOutSensor := "DB_Inputs".Sensors["cInBG3064"]); + // Stausensor Str.1 (KR-K1101 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3065", + nInSensorNo := "cInBG3065", + stInOutSensor := "DB_Inputs".Sensors["cInBG3065"]); + // Sensor Förderer voll (ILS-CV M1106) + #fbSensorInput(stInSensorHW := "BG3066", + nInSensorNo := "cInBG3066", + stInOutSensor := "DB_Inputs".Sensors["cInBG3066"]); + // Prüfung MT Pos.2 (KR-K1101 Einfahrt Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3067", + nInSensorNo := "cInBG3067", + stInOutSensor := "DB_Inputs".Sensors["cInBG3067"]); + // Prüfung MT Pos.3 (KR-K1101 Einfahrt Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3070", + nInSensorNo := "cInBG3070", + stInOutSensor := "DB_Inputs".Sensors["cInBG3070"]); + // Prüfung MT Pos.4 (KR-K1101 Einfahrt Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3071", + nInSensorNo := "cInBG3071", + stInOutSensor := "DB_Inputs".Sensors["cInBG3071"]); + // Prüfung MT Pos.5 (KR-K1101 Einfahrt Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3072", + nInSensorNo := "cInBG3072", + stInOutSensor := "DB_Inputs".Sensors["cInBG3072"]); + // Stausensor MT vor Pinband (KR-M1101 Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3073", + nInSensorNo := "cInBG3073", + stInOutSensor := "DB_Inputs".Sensors["cInBG3073"]); + // Stausensor Str.1 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3090", + nInSensorNo := "cInBG3090", + stInOutSensor := "DB_Inputs".Sensors["cInBG3090"]); + // Stausensor Str.2 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3091", + nInSensorNo := "cInBG3091", + stInOutSensor := "DB_Inputs".Sensors["cInBG3091"]); + // Stausensor Str.3 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3092", + nInSensorNo := "cInBG3092", + stInOutSensor := "DB_Inputs".Sensors["cInBG3092"]); + // Stausensor Str.4 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3093", + nInSensorNo := "cInBG3093", + stInOutSensor := "DB_Inputs".Sensors["cInBG3093"]); + // Stausensor Str.5 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3094", + nInSensorNo := "cInBG3094", + stInOutSensor := "DB_Inputs".Sensors["cInBG3094"]); + // Stausensor Str.6 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3095", + nInSensorNo := "cInBG3095", + stInOutSensor := "DB_Inputs".Sensors["cInBG3095"]); + // Stausensor Str.7 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3096", + nInSensorNo := "cInBG3096", + stInOutSensor := "DB_Inputs".Sensors["cInBG3096"]); + // Stausensor Str.8 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3097", + nInSensorNo := "cInBG3097", + stInOutSensor := "DB_Inputs".Sensors["cInBG3097"]); + // Stausensor Str.9 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3100", + nInSensorNo := "cInBG3100", + stInOutSensor := "DB_Inputs".Sensors["cInBG3100"]); + // Stausensor Str.10 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3101", + nInSensorNo := "cInBG3101", + stInOutSensor := "DB_Inputs".Sensors["cInBG3101"]); + // Stausensor Str.11 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3102", + nInSensorNo := "cInBG3102", + stInOutSensor := "DB_Inputs".Sensors["cInBG3102"]); + // Stausensor Str.12 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3103", + nInSensorNo := "cInBG3103", + stInOutSensor := "DB_Inputs".Sensors["cInBG3103"]); + // Stausensor Str.13 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3104", + nInSensorNo := "cInBG3104", + stInOutSensor := "DB_Inputs".Sensors["cInBG3104"]); + // Stausensor Str.14 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3105", + nInSensorNo := "cInBG3105", + stInOutSensor := "DB_Inputs".Sensors["cInBG3105"]); + // Stausensor Str.15 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3106", + nInSensorNo := "cInBG3106", + stInOutSensor := "DB_Inputs".Sensors["cInBG3106"]); + // Stausensor Str.16 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3107", + nInSensorNo := "cInBG3107", + stInOutSensor := "DB_Inputs".Sensors["cInBG3107"]); + // Stausensor Str.17 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3110", + nInSensorNo := "cInBG3110", + stInOutSensor := "DB_Inputs".Sensors["cInBG3110"]); + // in Separator 2 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3120", + nInSensorNo := "cInBG3120", + stInOutSensor := "DB_Inputs".Sensors["cInBG3120"]); + // Pin Abfrage (KR-M1102 ) Block 1.1.3 + #fbSensorInput(stInSensorHW := "BG3121", + nInSensorNo := "cInBG3121", + stInOutSensor := "DB_Inputs".Sensors["cInBG3121"]); + // Prüfung MT Pos.1 (KR-K1102 Einfahrt Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3122", + nInSensorNo := "cInBG3122", + stInOutSensor := "DB_Inputs".Sensors["cInBG3122"]); + // Stausensor Str.2 (KR-M1102) + #fbSensorInput(stInSensorHW := "BG3123", + nInSensorNo := "cInBG3123", + stInOutSensor := "DB_Inputs".Sensors["cInBG3123"]); + // in Separator 1 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3124", + nInSensorNo := "cInBG3124", + stInOutSensor := "DB_Inputs".Sensors["cInBG3124"]); + // Stausensor Str.1 (KR-K1102 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3125", + nInSensorNo := "cInBG3125", + stInOutSensor := "DB_Inputs".Sensors["cInBG3125"]); + // Sensor Förderer voll (ILS-CV 1106) + #fbSensorInput(stInSensorHW := "BG3126", + nInSensorNo := "cInBG3126", + stInOutSensor := "DB_Inputs".Sensors["cInBG3126"]); + // Prüfung MT Pos.2 (KR-K1102 Einfahrt Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3127", + nInSensorNo := "cInBG3127", + stInOutSensor := "DB_Inputs".Sensors["cInBG3127"]); + // Prüfung MT Pos.3 (KR-K1102 Einfahrt Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3130", + nInSensorNo := "cInBG3130", + stInOutSensor := "DB_Inputs".Sensors["cInBG3130"]); + // Prüfung MT Pos.4 (KR-K1102 Einfahrt Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3131", + nInSensorNo := "cInBG3131", + stInOutSensor := "DB_Inputs".Sensors["cInBG3131"]); + // Prüfung MT Pos.5 (KR-K1102 Einfahrt Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3132", + nInSensorNo := "cInBG3132", + stInOutSensor := "DB_Inputs".Sensors["cInBG3132"]); + // Prüfung MT Pos.6 (KR-K1102 Einfahrt Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3133", + nInSensorNo := "cInBG3133", + stInOutSensor := "DB_Inputs".Sensors["cInBG3133"]); + // in Separator 3 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3134", + nInSensorNo := "cInBG3134", + stInOutSensor := "DB_Inputs".Sensors["cInBG3134"]); + // Stausensor 1 (M1109) + #fbSensorInput(stInSensorHW := "BG3135", + nInSensorNo := "cInBG3135", + stInOutSensor := "DB_Inputs".Sensors["cInBG3135"]); + // Sensor Förderer voll (ILS-CV M1109) + #fbSensorInput(stInSensorHW := "BG3136", + nInSensorNo := "cInBG3136", + stInOutSensor := "DB_Inputs".Sensors["cInBG3136"]); + // in Separator 4 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3137", + nInSensorNo := "cInBG3137", + stInOutSensor := "DB_Inputs".Sensors["cInBG3137"]); + // Stausensor 2 (KR-M1102) + #fbSensorInput(stInSensorHW := "BG3141", + nInSensorNo := "cInBG3141", + stInOutSensor := "DB_Inputs".Sensors["cInBG3141"]); + // Stausensor MT vor Pinband (KR-M1102 Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3142", + nInSensorNo := "cInBG3142", + stInOutSensor := "DB_Inputs".Sensors["cInBG3142"]); + // in Separator (ILS-CV M1109) + #fbSensorInput(stInSensorHW := "BG3143", + nInSensorNo := "cInBG3143", + stInOutSensor := "DB_Inputs".Sensors["cInBG3143"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1109) + #fbSensorInput(stInSensorHW := "BG3144", + nInSensorNo := "cInBG3144", + stInOutSensor := "DB_Inputs".Sensors["cInBG3144"]); + // MT in Position (ILS-CV M1109) + #fbSensorInput(stInSensorHW := "BG3145", + nInSensorNo := "cInBG3145", + stInOutSensor := "DB_Inputs".Sensors["cInBG3145"]); + // Stausensor Str.1 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3150", + nInSensorNo := "cInBG3150", + stInOutSensor := "DB_Inputs".Sensors["cInBG3150"]); + // Stausensor Str.2 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3151", + nInSensorNo := "cInBG3151", + stInOutSensor := "DB_Inputs".Sensors["cInBG3151"]); + // Stausensor Str.3 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3152", + nInSensorNo := "cInBG3152", + stInOutSensor := "DB_Inputs".Sensors["cInBG3152"]); + // Stausensor Str.4 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3153", + nInSensorNo := "cInBG3153", + stInOutSensor := "DB_Inputs".Sensors["cInBG3153"]); + // Stausensor Str.5 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3154", + nInSensorNo := "cInBG3154", + stInOutSensor := "DB_Inputs".Sensors["cInBG3154"]); + // Stausensor Str.6 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3155", + nInSensorNo := "cInBG3155", + stInOutSensor := "DB_Inputs".Sensors["cInBG3155"]); + // Stausensor Str.7 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3156", + nInSensorNo := "cInBG3156", + stInOutSensor := "DB_Inputs".Sensors["cInBG3156"]); + // Stausensor Str.8 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3157", + nInSensorNo := "cInBG3157", + stInOutSensor := "DB_Inputs".Sensors["cInBG3157"]); + // Stausensor Str.9 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3160", + nInSensorNo := "cInBG3160", + stInOutSensor := "DB_Inputs".Sensors["cInBG3160"]); + // Stausensor Str.10 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3161", + nInSensorNo := "cInBG3161", + stInOutSensor := "DB_Inputs".Sensors["cInBG3161"]); + // Stausensor Str.11 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3162", + nInSensorNo := "cInBG3162", + stInOutSensor := "DB_Inputs".Sensors["cInBG3162"]); + // Stausensor Str.12 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3163", + nInSensorNo := "cInBG3163", + stInOutSensor := "DB_Inputs".Sensors["cInBG3163"]); + // Stausensor Str.13 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3164", + nInSensorNo := "cInBG3164", + stInOutSensor := "DB_Inputs".Sensors["cInBG3164"]); + // Stausensor Str.14 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3165", + nInSensorNo := "cInBG3165", + stInOutSensor := "DB_Inputs".Sensors["cInBG3165"]); + // Stausensor Str.15 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3166", + nInSensorNo := "cInBG3166", + stInOutSensor := "DB_Inputs".Sensors["cInBG3166"]); + // Stausensor Str.16 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3167", + nInSensorNo := "cInBG3167", + stInOutSensor := "DB_Inputs".Sensors["cInBG3167"]); + // Stausensor Str.17 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3170", + nInSensorNo := "cInBG3170", + stInOutSensor := "DB_Inputs".Sensors["cInBG3170"]); + // Stausensor Str.18 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3171", + nInSensorNo := "cInBG3171", + stInOutSensor := "DB_Inputs".Sensors["cInBG3171"]); + // Stausensor Str.19 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3172", + nInSensorNo := "cInBG3172", + stInOutSensor := "DB_Inputs".Sensors["cInBG3172"]); + // Stausensor Str.20 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3173", + nInSensorNo := "cInBG3173", + stInOutSensor := "DB_Inputs".Sensors["cInBG3173"]); + // Stausensor Str.21 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3174", + nInSensorNo := "cInBG3174", + stInOutSensor := "DB_Inputs".Sensors["cInBG3174"]); + // in Separator 2 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3180", + nInSensorNo := "cInBG3180", + stInOutSensor := "DB_Inputs".Sensors["cInBG3180"]); + // Pin Abfrage (KR-M1102 ) Block 1.1.4 + #fbSensorInput(stInSensorHW := "BG3181", + nInSensorNo := "cInBG3181", + stInOutSensor := "DB_Inputs".Sensors["cInBG3181"]); + // Prüfung MT Pos.1 (KR-K1102 Einfahrt Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3182", + nInSensorNo := "cInBG3182", + stInOutSensor := "DB_Inputs".Sensors["cInBG3182"]); + // Stausensor Str.2 (M1102) + #fbSensorInput(stInSensorHW := "BG3183", + nInSensorNo := "cInBG3183", + stInOutSensor := "DB_Inputs".Sensors["cInBG3183"]); + // in Separator 1 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3184", + nInSensorNo := "cInBG3184", + stInOutSensor := "DB_Inputs".Sensors["cInBG3184"]); + // Stausensor Str.1 (KR-K1102 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3185", + nInSensorNo := "cInBG3185", + stInOutSensor := "DB_Inputs".Sensors["cInBG3185"]); + // Sensor Förderer voll (ILS-CV 1102) + #fbSensorInput(stInSensorHW := "BG3186", + nInSensorNo := "cInBG3186", + stInOutSensor := "DB_Inputs".Sensors["cInBG3186"]); + // Prüfung MT Pos.2 (KR-K1102 Einfahrt Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3187", + nInSensorNo := "cInBG3187", + stInOutSensor := "DB_Inputs".Sensors["cInBG3187"]); + // Prüfung MT Pos.3 (KR-K1102 Einfahrt Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3190", + nInSensorNo := "cInBG3190", + stInOutSensor := "DB_Inputs".Sensors["cInBG3190"]); + // Prüfung MT Pos.4 (KR-K1102 Einfahrt Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3191", + nInSensorNo := "cInBG3191", + stInOutSensor := "DB_Inputs".Sensors["cInBG3191"]); + // Stausensor Str.1 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3210", + nInSensorNo := "cInBG3210", + stInOutSensor := "DB_Inputs".Sensors["cInBG3210"]); + // Stausensor Str.2 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3211", + nInSensorNo := "cInBG3211", + stInOutSensor := "DB_Inputs".Sensors["cInBG3211"]); + // Stausensor Str.3 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3212", + nInSensorNo := "cInBG3212", + stInOutSensor := "DB_Inputs".Sensors["cInBG3212"]); + // Stausensor Str.4 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3213", + nInSensorNo := "cInBG3213", + stInOutSensor := "DB_Inputs".Sensors["cInBG3213"]); + // Stausensor Str.5 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3214", + nInSensorNo := "cInBG3214", + stInOutSensor := "DB_Inputs".Sensors["cInBG3214"]); + // Stausensor Str.6 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3215", + nInSensorNo := "cInBG3215", + stInOutSensor := "DB_Inputs".Sensors["cInBG3215"]); + // Stausensor Str.7 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3216", + nInSensorNo := "cInBG3216", + stInOutSensor := "DB_Inputs".Sensors["cInBG3216"]); + // Stausensor Str.8 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3217", + nInSensorNo := "cInBG3217", + stInOutSensor := "DB_Inputs".Sensors["cInBG3217"]); + // Stausensor Str.9 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3220", + nInSensorNo := "cInBG3220", + stInOutSensor := "DB_Inputs".Sensors["cInBG3220"]); + // Stausensor Str.10 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3221", + nInSensorNo := "cInBG3221", + stInOutSensor := "DB_Inputs".Sensors["cInBG3221"]); + // Stausensor Str.11 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3222", + nInSensorNo := "cInBG3222", + stInOutSensor := "DB_Inputs".Sensors["cInBG3222"]); + // Stausensor Str.12 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3223", + nInSensorNo := "cInBG3223", + stInOutSensor := "DB_Inputs".Sensors["cInBG3223"]); + // Stausensor Str.13 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3224", + nInSensorNo := "cInBG3224", + stInOutSensor := "DB_Inputs".Sensors["cInBG3224"]); + // in Separator 1 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3240", + nInSensorNo := "cInBG3240", + stInOutSensor := "DB_Inputs".Sensors["cInBG3240"]); + // Staumelder, Einfahrt (ILS-CV M1105) + #fbSensorInput(stInSensorHW := "BG3241", + nInSensorNo := "cInBG3241", + stInOutSensor := "DB_Inputs".Sensors["cInBG3241"]); + // Stausensor 1 (KR-M1103 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3242", + nInSensorNo := "cInBG3242", + stInOutSensor := "DB_Inputs".Sensors["cInBG3242"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1105) + #fbSensorInput(stInSensorHW := "BG3243", + nInSensorNo := "cInBG3243", + stInOutSensor := "DB_Inputs".Sensors["cInBG3243"]); + // in Separator 2 (ILS-CV M1105) + #fbSensorInput(stInSensorHW := "BG3244", + nInSensorNo := "cInBG3244", + stInOutSensor := "DB_Inputs".Sensors["cInBG3244"]); + // in Separator (KR-M1103) + #fbSensorInput(stInSensorHW := "BG3245", + nInSensorNo := "cInBG3245", + stInOutSensor := "DB_Inputs".Sensors["cInBG3245"]); + // MT in Position (ILS-CV M1105) + #fbSensorInput(stInSensorHW := "BG3247", + nInSensorNo := "cInBG3247", + stInOutSensor := "DB_Inputs".Sensors["cInBG3247"]); + // in Separator 1 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3270", + nInSensorNo := "cInBG3270", + stInOutSensor := "DB_Inputs".Sensors["cInBG3270"]); + // in Separator 2 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3271", + nInSensorNo := "cInBG3271", + stInOutSensor := "DB_Inputs".Sensors["cInBG3271"]); + // in Separator 3 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3272", + nInSensorNo := "cInBG3272", + stInOutSensor := "DB_Inputs".Sensors["cInBG3272"]); + // in Separator 4 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3273", + nInSensorNo := "cInBG3273", + stInOutSensor := "DB_Inputs".Sensors["cInBG3273"]); + // in Separator 5 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3274", + nInSensorNo := "cInBG3274", + stInOutSensor := "DB_Inputs".Sensors["cInBG3274"]); + // in Separator 6 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3275", + nInSensorNo := "cInBG3275", + stInOutSensor := "DB_Inputs".Sensors["cInBG3275"]); + // in Separator 7 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3276", + nInSensorNo := "cInBG3276", + stInOutSensor := "DB_Inputs".Sensors["cInBG3276"]); + // in Separator 8 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3277", + nInSensorNo := "cInBG3277", + stInOutSensor := "DB_Inputs".Sensors["cInBG3277"]); + // in Separator 9 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3280", + nInSensorNo := "cInBG3280", + stInOutSensor := "DB_Inputs".Sensors["cInBG3280"]); + // in Separator 10 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3281", + nInSensorNo := "cInBG3281", + stInOutSensor := "DB_Inputs".Sensors["cInBG3281"]); + // in Separator 11 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3282", + nInSensorNo := "cInBG3282", + stInOutSensor := "DB_Inputs".Sensors["cInBG3282"]); + // in Separator 12 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3283", + nInSensorNo := "cInBG3283", + stInOutSensor := "DB_Inputs".Sensors["cInBG3283"]); + // in Separator 13 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3284", + nInSensorNo := "cInBG3284", + stInOutSensor := "DB_Inputs".Sensors["cInBG3284"]); + // in Separator 14 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3285", + nInSensorNo := "cInBG3285", + stInOutSensor := "DB_Inputs".Sensors["cInBG3285"]); + // in Separator 15 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3286", + nInSensorNo := "cInBG3286", + stInOutSensor := "DB_Inputs".Sensors["cInBG3286"]); + // in Separator 16 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3287", + nInSensorNo := "cInBG3287", + stInOutSensor := "DB_Inputs".Sensors["cInBG3287"]); + // in Separator 17 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3290", + nInSensorNo := "cInBG3290", + stInOutSensor := "DB_Inputs".Sensors["cInBG3290"]); + // in Separator 18 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3291", + nInSensorNo := "cInBG3291", + stInOutSensor := "DB_Inputs".Sensors["cInBG3291"]); + // In Separator 19 (Block 1.1.1) + #fbSensorInput(stInSensorHW := "BG3292", + nInSensorNo := "cInBG3292", + stInOutSensor := "DB_Inputs".Sensors["cInBG3292"]); + // in Separator 1 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3300", + nInSensorNo := "cInBG3300", + stInOutSensor := "DB_Inputs".Sensors["cInBG3300"]); + // Staumelder, Einfahrt (ILS-CV M1106 Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3301", + nInSensorNo := "cInBG3301", + stInOutSensor := "DB_Inputs".Sensors["cInBG3301"]); + // Stausensor 1 (KR-M1103 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3302", + nInSensorNo := "cInBG3302", + stInOutSensor := "DB_Inputs".Sensors["cInBG3302"]); + // Abfrage Mitnehmerfinger in Position (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3303", + nInSensorNo := "cInBG3303", + stInOutSensor := "DB_Inputs".Sensors["cInBG3303"]); + // in Separator 2 (ILS-CV M1106 Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3304", + nInSensorNo := "cInBG3304", + stInOutSensor := "DB_Inputs".Sensors["cInBG3304"]); + // Stausensor 3 (KR-M1103) + #fbSensorInput(stInSensorHW := "BG3305", + nInSensorNo := "cInBG3305", + stInOutSensor := "DB_Inputs".Sensors["cInBG3305"]); + // Rad dreht (KR-M1103) + #fbSensorInput(stInSensorHW := "BG3306", + nInSensorNo := "cInBG3306", + stInOutSensor := "DB_Inputs".Sensors["cInBG3306"]); + // MT in Position (ILS-CV M1106) + #fbSensorInput(stInSensorHW := "BG3307", + nInSensorNo := "cInBG3307", + stInOutSensor := "DB_Inputs".Sensors["cInBG3307"]); + // in Separator 1 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3330", + nInSensorNo := "cInBG3330", + stInOutSensor := "DB_Inputs".Sensors["cInBG3330"]); + // in Separator 2 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3331", + nInSensorNo := "cInBG3331", + stInOutSensor := "DB_Inputs".Sensors["cInBG3331"]); + // in Separator 3 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3332", + nInSensorNo := "cInBG3332", + stInOutSensor := "DB_Inputs".Sensors["cInBG3332"]); + // in Separator 4 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3333", + nInSensorNo := "cInBG3333", + stInOutSensor := "DB_Inputs".Sensors["cInBG3333"]); + // in Separator 5 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3334", + nInSensorNo := "cInBG3334", + stInOutSensor := "DB_Inputs".Sensors["cInBG3334"]); + // in Separator 6 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3335", + nInSensorNo := "cInBG3335", + stInOutSensor := "DB_Inputs".Sensors["cInBG3335"]); + // in Separator 7 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3336", + nInSensorNo := "cInBG3336", + stInOutSensor := "DB_Inputs".Sensors["cInBG3336"]); + // in Separator 8 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3337", + nInSensorNo := "cInBG3337", + stInOutSensor := "DB_Inputs".Sensors["cInBG3337"]); + // in Separator 9 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3340", + nInSensorNo := "cInBG3340", + stInOutSensor := "DB_Inputs".Sensors["cInBG3340"]); + // in Separator 10 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3341", + nInSensorNo := "cInBG3341", + stInOutSensor := "DB_Inputs".Sensors["cInBG3341"]); + // in Separator 11 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3342", + nInSensorNo := "cInBG3342", + stInOutSensor := "DB_Inputs".Sensors["cInBG3342"]); + // in Separator 12 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3343", + nInSensorNo := "cInBG3343", + stInOutSensor := "DB_Inputs".Sensors["cInBG3343"]); + // in Separator 13 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3344", + nInSensorNo := "cInBG3344", + stInOutSensor := "DB_Inputs".Sensors["cInBG3344"]); + // in Separator 14 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3345", + nInSensorNo := "cInBG3345", + stInOutSensor := "DB_Inputs".Sensors["cInBG3345"]); + // in Separator 15 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3346", + nInSensorNo := "cInBG3346", + stInOutSensor := "DB_Inputs".Sensors["cInBG3346"]); + // in Separator 16 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3347", + nInSensorNo := "cInBG3347", + stInOutSensor := "DB_Inputs".Sensors["cInBG3347"]); + // in Separator 17 (Block 1.1.2) + #fbSensorInput(stInSensorHW := "BG3350", + nInSensorNo := "cInBG3350", + stInOutSensor := "DB_Inputs".Sensors["cInBG3350"]); + // in Separator 1 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3360", + nInSensorNo := "cInBG3360", + stInOutSensor := "DB_Inputs".Sensors["cInBG3360"]); + // Staumelder, Einfahrt (ILS-CV M1107) + #fbSensorInput(stInSensorHW := "BG3361", + nInSensorNo := "cInBG3361", + stInOutSensor := "DB_Inputs".Sensors["cInBG3361"]); + // Stausensor 1 (KR-M1104 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3362", + nInSensorNo := "cInBG3362", + stInOutSensor := "DB_Inputs".Sensors["cInBG3362"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1107) + #fbSensorInput(stInSensorHW := "BG3363", + nInSensorNo := "cInBG3363", + stInOutSensor := "DB_Inputs".Sensors["cInBG3363"]); + // in Separator 2 (ILS-CV M1107) + #fbSensorInput(stInSensorHW := "BG3364", + nInSensorNo := "cInBG3364", + stInOutSensor := "DB_Inputs".Sensors["cInBG3364"]); + // Stausensor (ILS-KR-M1104) + #fbSensorInput(stInSensorHW := "BG3365", + nInSensorNo := "cInBG3365", + stInOutSensor := "DB_Inputs".Sensors["cInBG3365"]); + // MT in Position (ILS-CV M1107) + #fbSensorInput(stInSensorHW := "BG3367", + nInSensorNo := "cInBG3367", + stInOutSensor := "DB_Inputs".Sensors["cInBG3367"]); + // in Separator 1 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3390", + nInSensorNo := "cInBG3390", + stInOutSensor := "DB_Inputs".Sensors["cInBG3390"]); + // in Separator 2 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3391", + nInSensorNo := "cInBG3391", + stInOutSensor := "DB_Inputs".Sensors["cInBG3391"]); + // in Separator 3 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3392", + nInSensorNo := "cInBG3392", + stInOutSensor := "DB_Inputs".Sensors["cInBG3392"]); + // in Separator 4 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3393", + nInSensorNo := "cInBG3393", + stInOutSensor := "DB_Inputs".Sensors["cInBG3393"]); + // in Separator 5 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3394", + nInSensorNo := "cInBG3394", + stInOutSensor := "DB_Inputs".Sensors["cInBG3394"]); + // in Separator 6 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3395", + nInSensorNo := "cInBG3395", + stInOutSensor := "DB_Inputs".Sensors["cInBG3395"]); + // in Separator 7 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3396", + nInSensorNo := "cInBG3396", + stInOutSensor := "DB_Inputs".Sensors["cInBG3396"]); + // in Separator 8 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3397", + nInSensorNo := "cInBG3397", + stInOutSensor := "DB_Inputs".Sensors["cInBG3397"]); + // in Separator 9 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3400", + nInSensorNo := "cInBG3400", + stInOutSensor := "DB_Inputs".Sensors["cInBG3400"]); + // in Separator 10 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3401", + nInSensorNo := "cInBG3401", + stInOutSensor := "DB_Inputs".Sensors["cInBG3401"]); + // in Separator 11 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3402", + nInSensorNo := "cInBG3402", + stInOutSensor := "DB_Inputs".Sensors["cInBG3402"]); + // in Separator 12 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3403", + nInSensorNo := "cInBG3403", + stInOutSensor := "DB_Inputs".Sensors["cInBG3403"]); + // in Separator 13 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3404", + nInSensorNo := "cInBG3404", + stInOutSensor := "DB_Inputs".Sensors["cInBG3404"]); + // in Separator 14 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3405", + nInSensorNo := "cInBG3405", + stInOutSensor := "DB_Inputs".Sensors["cInBG3405"]); + // in Separator 15 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3406", + nInSensorNo := "cInBG3406", + stInOutSensor := "DB_Inputs".Sensors["cInBG3406"]); + // in Separator 16 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3407", + nInSensorNo := "cInBG3407", + stInOutSensor := "DB_Inputs".Sensors["cInBG3407"]); + // in Separator 17 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3410", + nInSensorNo := "cInBG3410", + stInOutSensor := "DB_Inputs".Sensors["cInBG3410"]); + // in Separator 18 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3411", + nInSensorNo := "cInBG3411", + stInOutSensor := "DB_Inputs".Sensors["cInBG3411"]); + // in Separator 19 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3412", + nInSensorNo := "cInBG3412", + stInOutSensor := "DB_Inputs".Sensors["cInBG3412"]); + // in Separator 20 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3413", + nInSensorNo := "cInBG3413", + stInOutSensor := "DB_Inputs".Sensors["cInBG3413"]); + // in Separator 21 (Block 1.1.3) + #fbSensorInput(stInSensorHW := "BG3414", + nInSensorNo := "cInBG3414", + stInOutSensor := "DB_Inputs".Sensors["cInBG3414"]); + // in Separator 1 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3420", + nInSensorNo := "cInBG3420", + stInOutSensor := "DB_Inputs".Sensors["cInBG3420"]); + // Staumelder, Einfahrt (ILS-CV M1108) + #fbSensorInput(stInSensorHW := "BG3421", + nInSensorNo := "cInBG3421", + stInOutSensor := "DB_Inputs".Sensors["cInBG3421"]); + // Stausensor 1 (KR-M1104 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3422", + nInSensorNo := "cInBG3422", + stInOutSensor := "DB_Inputs".Sensors["cInBG3422"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1108) + #fbSensorInput(stInSensorHW := "BG3423", + nInSensorNo := "cInBG3423", + stInOutSensor := "DB_Inputs".Sensors["cInBG3423"]); + // in Separator 2 (ILS-CV M1108) + #fbSensorInput(stInSensorHW := "BG3424", + nInSensorNo := "cInBG3424", + stInOutSensor := "DB_Inputs".Sensors["cInBG3424"]); + // in Separator 3 (ILS-CV M1104) + #fbSensorInput(stInSensorHW := "BG3425", + nInSensorNo := "cInBG3425", + stInOutSensor := "DB_Inputs".Sensors["cInBG3425"]); + // Stausensor 3 (KR-M1104) + #fbSensorInput(stInSensorHW := "BG3426", + nInSensorNo := "cInBG3426", + stInOutSensor := "DB_Inputs".Sensors["cInBG3426"]); + // MT in Position (ILS-CV M1108) + #fbSensorInput(stInSensorHW := "BG3427", + nInSensorNo := "cInBG3427", + stInOutSensor := "DB_Inputs".Sensors["cInBG3427"]); + // Stausensor 1 (M2109) + #fbSensorInput(stInSensorHW := "BG3431", + nInSensorNo := "cInBG3431", + stInOutSensor := "DB_Inputs".Sensors["cInBG3431"]); + // Rad dreht (KR-M1104) + #fbSensorInput(stInSensorHW := "BG3433", + nInSensorNo := "cInBG3433", + stInOutSensor := "DB_Inputs".Sensors["cInBG3433"]); + // in Separator 1 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3450", + nInSensorNo := "cInBG3450", + stInOutSensor := "DB_Inputs".Sensors["cInBG3450"]); + // in Separator 2 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3451", + nInSensorNo := "cInBG3451", + stInOutSensor := "DB_Inputs".Sensors["cInBG3451"]); + // in Separator 3 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3452", + nInSensorNo := "cInBG3452", + stInOutSensor := "DB_Inputs".Sensors["cInBG3452"]); + // in Separator 4 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3453", + nInSensorNo := "cInBG3453", + stInOutSensor := "DB_Inputs".Sensors["cInBG3453"]); + // in Separator 5 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3454", + nInSensorNo := "cInBG3454", + stInOutSensor := "DB_Inputs".Sensors["cInBG3454"]); + // in Separator 6 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3455", + nInSensorNo := "cInBG3455", + stInOutSensor := "DB_Inputs".Sensors["cInBG3455"]); + // in Separator 7 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3456", + nInSensorNo := "cInBG3456", + stInOutSensor := "DB_Inputs".Sensors["cInBG3456"]); + // in Separator 8 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3457", + nInSensorNo := "cInBG3457", + stInOutSensor := "DB_Inputs".Sensors["cInBG3457"]); + // in Separator 9 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3460", + nInSensorNo := "cInBG3460", + stInOutSensor := "DB_Inputs".Sensors["cInBG3460"]); + // in Separator 10 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3461", + nInSensorNo := "cInBG3461", + stInOutSensor := "DB_Inputs".Sensors["cInBG3461"]); + // in Separator 11 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3462", + nInSensorNo := "cInBG3462", + stInOutSensor := "DB_Inputs".Sensors["cInBG3462"]); + // in Separator 12 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3463", + nInSensorNo := "cInBG3463", + stInOutSensor := "DB_Inputs".Sensors["cInBG3463"]); + // in Separator 13 (Block 1.1.4) + #fbSensorInput(stInSensorHW := "BG3464", + nInSensorNo := "cInBG3464", + stInOutSensor := "DB_Inputs".Sensors["cInBG3464"]); + // in Separator 2 (ILS-CV M1205) + #fbSensorInput(stInSensorHW := "BG3480", + nInSensorNo := "cInBG3480", + stInOutSensor := "DB_Inputs".Sensors["cInBG3480"]); + // Pin Abfrage (KR-M1201 ) Block 1.2.1 + #fbSensorInput(stInSensorHW := "BG3481", + nInSensorNo := "cInBG3481", + stInOutSensor := "DB_Inputs".Sensors["cInBG3481"]); + // Prüfung MT Pos.1 (KR-K1201 Einfahrt Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3482", + nInSensorNo := "cInBG3482", + stInOutSensor := "DB_Inputs".Sensors["cInBG3482"]); + // Stausensor (KR-M1201) + #fbSensorInput(stInSensorHW := "BG3483", + nInSensorNo := "cInBG3483", + stInOutSensor := "DB_Inputs".Sensors["cInBG3483"]); + // in Separator 1 (ILS-CV M1205) + #fbSensorInput(stInSensorHW := "BG3484", + nInSensorNo := "cInBG3484", + stInOutSensor := "DB_Inputs".Sensors["cInBG3484"]); + // Stausensor Str.1 (ILS-CV M1205) + #fbSensorInput(stInSensorHW := "BG3485", + nInSensorNo := "cInBG3485", + stInOutSensor := "DB_Inputs".Sensors["cInBG3485"]); + // Sensor Förderer voll (ILS-CV M1205) + #fbSensorInput(stInSensorHW := "BG3486", + nInSensorNo := "cInBG3486", + stInOutSensor := "DB_Inputs".Sensors["cInBG3486"]); + // Prüfung MT Pos.2 (KR-K1201 Einfahrt Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3487", + nInSensorNo := "cInBG3487", + stInOutSensor := "DB_Inputs".Sensors["cInBG3487"]); + // Prüfung MT Pos.3 (KR-K1201 Einfahrt Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3490", + nInSensorNo := "cInBG3490", + stInOutSensor := "DB_Inputs".Sensors["cInBG3490"]); + // Prüfung MT Pos.4 (KR-K1201 Einfahrt Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3491", + nInSensorNo := "cInBG3491", + stInOutSensor := "DB_Inputs".Sensors["cInBG3491"]); + // Prüfung MT Pos.5 (KR-K1201 Einfahrt Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3492", + nInSensorNo := "cInBG3492", + stInOutSensor := "DB_Inputs".Sensors["cInBG3492"]); + // Stausensor Str.1 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3510", + nInSensorNo := "cInBG3510", + stInOutSensor := "DB_Inputs".Sensors["cInBG3510"]); + // Stausensor Str.2 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3511", + nInSensorNo := "cInBG3511", + stInOutSensor := "DB_Inputs".Sensors["cInBG3511"]); + // Stausensor Str.3 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3512", + nInSensorNo := "cInBG3512", + stInOutSensor := "DB_Inputs".Sensors["cInBG3512"]); + // Stausensor Str.4 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3513", + nInSensorNo := "cInBG3513", + stInOutSensor := "DB_Inputs".Sensors["cInBG3513"]); + // Stausensor Str.5 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3514", + nInSensorNo := "cInBG3514", + stInOutSensor := "DB_Inputs".Sensors["cInBG3514"]); + // Stausensor Str.6 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3515", + nInSensorNo := "cInBG3515", + stInOutSensor := "DB_Inputs".Sensors["cInBG3515"]); + // Stausensor Str.7 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3516", + nInSensorNo := "cInBG3516", + stInOutSensor := "DB_Inputs".Sensors["cInBG3516"]); + // Stausensor Str.8 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3517", + nInSensorNo := "cInBG3517", + stInOutSensor := "DB_Inputs".Sensors["cInBG3517"]); + // Stausensor Str.9 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3520", + nInSensorNo := "cInBG3520", + stInOutSensor := "DB_Inputs".Sensors["cInBG3520"]); + // Stausensor Str.10 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3521", + nInSensorNo := "cInBG3521", + stInOutSensor := "DB_Inputs".Sensors["cInBG3521"]); + // Stausensor Str.11 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3522", + nInSensorNo := "cInBG3522", + stInOutSensor := "DB_Inputs".Sensors["cInBG3522"]); + // Stausensor Str.12 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3523", + nInSensorNo := "cInBG3523", + stInOutSensor := "DB_Inputs".Sensors["cInBG3523"]); + // Stausensor Str.13 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3524", + nInSensorNo := "cInBG3524", + stInOutSensor := "DB_Inputs".Sensors["cInBG3524"]); + // Stausensor Str.14 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3525", + nInSensorNo := "cInBG3525", + stInOutSensor := "DB_Inputs".Sensors["cInBG3525"]); + // Stausensor Str.15 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3526", + nInSensorNo := "cInBG3526", + stInOutSensor := "DB_Inputs".Sensors["cInBG3526"]); + // Stausensor Str.16 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3527", + nInSensorNo := "cInBG3527", + stInOutSensor := "DB_Inputs".Sensors["cInBG3527"]); + // Stausensor Str.17 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3530", + nInSensorNo := "cInBG3530", + stInOutSensor := "DB_Inputs".Sensors["cInBG3530"]); + // Stausensor Str.18 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3531", + nInSensorNo := "cInBG3531", + stInOutSensor := "DB_Inputs".Sensors["cInBG3531"]); + // Stausensor Str.19 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3532", + nInSensorNo := "cInBG3532", + stInOutSensor := "DB_Inputs".Sensors["cInBG3532"]); + // in Separator 2 (ILS-CV M1206) + #fbSensorInput(stInSensorHW := "BG3540", + nInSensorNo := "cInBG3540", + stInOutSensor := "DB_Inputs".Sensors["cInBG3540"]); + // Pin Abfrage (KR-M1201 ) Block 1.2.2 + #fbSensorInput(stInSensorHW := "BG3541", + nInSensorNo := "cInBG3541", + stInOutSensor := "DB_Inputs".Sensors["cInBG3541"]); + // Prüfung MT Pos.1 (KR-K1201 Einfahrt Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3542", + nInSensorNo := "cInBG3542", + stInOutSensor := "DB_Inputs".Sensors["cInBG3542"]); + // Stausensor Str.2 (KR-M1201) + #fbSensorInput(stInSensorHW := "BG3543", + nInSensorNo := "cInBG3543", + stInOutSensor := "DB_Inputs".Sensors["cInBG3543"]); + // in Separator 1 (ILS-CV M1206) + #fbSensorInput(stInSensorHW := "BG3544", + nInSensorNo := "cInBG3544", + stInOutSensor := "DB_Inputs".Sensors["cInBG3544"]); + // Stausensor Str.1 (ILS-CV M1206) + #fbSensorInput(stInSensorHW := "BG3545", + nInSensorNo := "cInBG3545", + stInOutSensor := "DB_Inputs".Sensors["cInBG3545"]); + // Sensor Förderer voll (ILS-CV M1206) + #fbSensorInput(stInSensorHW := "BG3546", + nInSensorNo := "cInBG3546", + stInOutSensor := "DB_Inputs".Sensors["cInBG3546"]); + // Prüfung MT Pos.2 (KR-K1201 Einfahrt Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3547", + nInSensorNo := "cInBG3547", + stInOutSensor := "DB_Inputs".Sensors["cInBG3547"]); + // Prüfung MT Pos.3 (KR-K1201 Einfahrt Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3550", + nInSensorNo := "cInBG3550", + stInOutSensor := "DB_Inputs".Sensors["cInBG3550"]); + // Prüfung MT Pos.4 (KR-K1201 Einfahrt Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3551", + nInSensorNo := "cInBG3551", + stInOutSensor := "DB_Inputs".Sensors["cInBG3551"]); + // Prüfung MT Pos.5 (KR-K1201 Einfahrt Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3552", + nInSensorNo := "cInBG3552", + stInOutSensor := "DB_Inputs".Sensors["cInBG3552"]); + // Stausensor MT vor Pinband (KR-K1201) Block 1.2.2 + #fbSensorInput(stInSensorHW := "BG3553", + nInSensorNo := "cInBG3553", + stInOutSensor := "DB_Inputs".Sensors["cInBG3553"]); + // Stausensor Str.1 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3570", + nInSensorNo := "cInBG3570", + stInOutSensor := "DB_Inputs".Sensors["cInBG3570"]); + // Stausensor Str.2 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3571", + nInSensorNo := "cInBG3571", + stInOutSensor := "DB_Inputs".Sensors["cInBG3571"]); + // Stausensor Str.3 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3572", + nInSensorNo := "cInBG3572", + stInOutSensor := "DB_Inputs".Sensors["cInBG3572"]); + // Stausensor Str.4 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3573", + nInSensorNo := "cInBG3573", + stInOutSensor := "DB_Inputs".Sensors["cInBG3573"]); + // Stausensor Str.5 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3574", + nInSensorNo := "cInBG3574", + stInOutSensor := "DB_Inputs".Sensors["cInBG3574"]); + // Stausensor Str.6 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3575", + nInSensorNo := "cInBG3575", + stInOutSensor := "DB_Inputs".Sensors["cInBG3575"]); + // Stausensor Str.7 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3576", + nInSensorNo := "cInBG3576", + stInOutSensor := "DB_Inputs".Sensors["cInBG3576"]); + // Stausensor Str.8 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3577", + nInSensorNo := "cInBG3577", + stInOutSensor := "DB_Inputs".Sensors["cInBG3577"]); + // Stausensor Str.9 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3580", + nInSensorNo := "cInBG3580", + stInOutSensor := "DB_Inputs".Sensors["cInBG3580"]); + // Stausensor Str.10 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3581", + nInSensorNo := "cInBG3581", + stInOutSensor := "DB_Inputs".Sensors["cInBG3581"]); + // Stausensor Str.11 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3582", + nInSensorNo := "cInBG3582", + stInOutSensor := "DB_Inputs".Sensors["cInBG3582"]); + // Stausensor Str.12 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3583", + nInSensorNo := "cInBG3583", + stInOutSensor := "DB_Inputs".Sensors["cInBG3583"]); + // Stausensor Str.13 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3584", + nInSensorNo := "cInBG3584", + stInOutSensor := "DB_Inputs".Sensors["cInBG3584"]); + // Stausensor Str.14 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3585", + nInSensorNo := "cInBG3585", + stInOutSensor := "DB_Inputs".Sensors["cInBG3585"]); + // Stausensor Str.15 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3586", + nInSensorNo := "cInBG3586", + stInOutSensor := "DB_Inputs".Sensors["cInBG3586"]); + // Stausensor Str.16 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3587", + nInSensorNo := "cInBG3587", + stInOutSensor := "DB_Inputs".Sensors["cInBG3587"]); + // Stausensor Str.17 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3590", + nInSensorNo := "cInBG3590", + stInOutSensor := "DB_Inputs".Sensors["cInBG3590"]); + // in Separator 2 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3600", + nInSensorNo := "cInBG3600", + stInOutSensor := "DB_Inputs".Sensors["cInBG3600"]); + // Pin Abfrage (KR-M1202 ) Block 1.2.3 + #fbSensorInput(stInSensorHW := "BG3601", + nInSensorNo := "cInBG3601", + stInOutSensor := "DB_Inputs".Sensors["cInBG3601"]); + // Prüfung MT Pos.1 (KR-K1202 Einfahrt Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3602", + nInSensorNo := "cInBG3602", + stInOutSensor := "DB_Inputs".Sensors["cInBG3602"]); + // Stausensor Str.2 (KR-M1202) + #fbSensorInput(stInSensorHW := "BG3603", + nInSensorNo := "cInBG3603", + stInOutSensor := "DB_Inputs".Sensors["cInBG3603"]); + // in Separator 1 (ILS-CV M1207) + #fbSensorInput(stInSensorHW := "BG3604", + nInSensorNo := "cInBG3604", + stInOutSensor := "DB_Inputs".Sensors["cInBG3604"]); + // Stausensor Str.1 (KR-K1207 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3605", + nInSensorNo := "cInBG3605", + stInOutSensor := "DB_Inputs".Sensors["cInBG3605"]); + // Sensor Förderer voll (ILS-CV M1207) + #fbSensorInput(stInSensorHW := "BG3606", + nInSensorNo := "cInBG3606", + stInOutSensor := "DB_Inputs".Sensors["cInBG3606"]); + // Prüfung MT Pos.2 (KR-K1202 Einfahrt Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3607", + nInSensorNo := "cInBG3607", + stInOutSensor := "DB_Inputs".Sensors["cInBG3607"]); + // Prüfung MT Pos.3 (KR-K1202 Einfahrt Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3610", + nInSensorNo := "cInBG3610", + stInOutSensor := "DB_Inputs".Sensors["cInBG3610"]); + // Prüfung MT Pos.4 (KR-K1202 Einfahrt Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3611", + nInSensorNo := "cInBG3611", + stInOutSensor := "DB_Inputs".Sensors["cInBG3611"]); + // Prüfung MT Pos.5 (KR-K1202 Einfahrt Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3612", + nInSensorNo := "cInBG3612", + stInOutSensor := "DB_Inputs".Sensors["cInBG3612"]); + // Prüfung MT Pos.6 (KR-K1202 Einfahrt Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3613", + nInSensorNo := "cInBG3613", + stInOutSensor := "DB_Inputs".Sensors["cInBG3613"]); + // in Separator 3 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3614", + nInSensorNo := "cInBG3614", + stInOutSensor := "DB_Inputs".Sensors["cInBG3614"]); + // Stausensor (M1209) + #fbSensorInput(stInSensorHW := "BG3615", + nInSensorNo := "cInBG3615", + stInOutSensor := "DB_Inputs".Sensors["cInBG3615"]); + // Sensor Förderer voll (ILS-CV M1209) + #fbSensorInput(stInSensorHW := "BG3616", + nInSensorNo := "cInBG3616", + stInOutSensor := "DB_Inputs".Sensors["cInBG3616"]); + // in Separator 4 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3617", + nInSensorNo := "cInBG3617", + stInOutSensor := "DB_Inputs".Sensors["cInBG3617"]); + // Stausensor 2 (KR-M1202) + #fbSensorInput(stInSensorHW := "BG3621", + nInSensorNo := "cInBG3621", + stInOutSensor := "DB_Inputs".Sensors["cInBG3621"]); + // in Separator (ILS-CV M1209) + #fbSensorInput(stInSensorHW := "BG3622", + nInSensorNo := "cInBG3622", + stInOutSensor := "DB_Inputs".Sensors["cInBG3622"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1209) + #fbSensorInput(stInSensorHW := "BG3623", + nInSensorNo := "cInBG3623", + stInOutSensor := "DB_Inputs".Sensors["cInBG3623"]); + // MT in Position (ILS-CV M1209) + #fbSensorInput(stInSensorHW := "BG3624", + nInSensorNo := "cInBG3624", + stInOutSensor := "DB_Inputs".Sensors["cInBG3624"]); + // Stausensor MT vor Pinband (KR-K1203) Block 1.2.3 + #fbSensorInput(stInSensorHW := "BG3625", + nInSensorNo := "cInBG3625", + stInOutSensor := "DB_Inputs".Sensors["cInBG3625"]); + // Stausensor Str.1 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3630", + nInSensorNo := "cInBG3630", + stInOutSensor := "DB_Inputs".Sensors["cInBG3630"]); + // Stausensor Str.2 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3631", + nInSensorNo := "cInBG3631", + stInOutSensor := "DB_Inputs".Sensors["cInBG3631"]); + // Stausensor Str.3 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3632", + nInSensorNo := "cInBG3632", + stInOutSensor := "DB_Inputs".Sensors["cInBG3632"]); + // Stausensor Str.4 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3633", + nInSensorNo := "cInBG3633", + stInOutSensor := "DB_Inputs".Sensors["cInBG3633"]); + // Stausensor Str.5 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3634", + nInSensorNo := "cInBG3634", + stInOutSensor := "DB_Inputs".Sensors["cInBG3634"]); + // Stausensor Str.6 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3635", + nInSensorNo := "cInBG3635", + stInOutSensor := "DB_Inputs".Sensors["cInBG3635"]); + // Stausensor Str.7 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3636", + nInSensorNo := "cInBG3636", + stInOutSensor := "DB_Inputs".Sensors["cInBG3636"]); + // Stausensor Str.8 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3637", + nInSensorNo := "cInBG3637", + stInOutSensor := "DB_Inputs".Sensors["cInBG3637"]); + // Stausensor Str.9 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3640", + nInSensorNo := "cInBG3640", + stInOutSensor := "DB_Inputs".Sensors["cInBG3640"]); + // Stausensor Str.10 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3641", + nInSensorNo := "cInBG3641", + stInOutSensor := "DB_Inputs".Sensors["cInBG3641"]); + // Stausensor Str.11 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3642", + nInSensorNo := "cInBG3642", + stInOutSensor := "DB_Inputs".Sensors["cInBG3642"]); + // Stausensor Str.12 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3643", + nInSensorNo := "cInBG3643", + stInOutSensor := "DB_Inputs".Sensors["cInBG3643"]); + // Stausensor Str.13 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3644", + nInSensorNo := "cInBG3644", + stInOutSensor := "DB_Inputs".Sensors["cInBG3644"]); + // Stausensor Str.14 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3645", + nInSensorNo := "cInBG3645", + stInOutSensor := "DB_Inputs".Sensors["cInBG3645"]); + // Stausensor Str.15 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3646", + nInSensorNo := "cInBG3646", + stInOutSensor := "DB_Inputs".Sensors["cInBG3646"]); + // Stausensor Str.16 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3647", + nInSensorNo := "cInBG3647", + stInOutSensor := "DB_Inputs".Sensors["cInBG3647"]); + // Stausensor Str.17 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3650", + nInSensorNo := "cInBG3650", + stInOutSensor := "DB_Inputs".Sensors["cInBG3650"]); + // Stausensor Str.18 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3651", + nInSensorNo := "cInBG3651", + stInOutSensor := "DB_Inputs".Sensors["cInBG3651"]); + // Stausensor Str.19 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3652", + nInSensorNo := "cInBG3652", + stInOutSensor := "DB_Inputs".Sensors["cInBG3652"]); + // Stausensor Str.20 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3653", + nInSensorNo := "cInBG3653", + stInOutSensor := "DB_Inputs".Sensors["cInBG3653"]); + // Stausensor Str.21 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3654", + nInSensorNo := "cInBG3654", + stInOutSensor := "DB_Inputs".Sensors["cInBG3654"]); + // in Separator 2 (ILS-CV M1208) + #fbSensorInput(stInSensorHW := "BG3660", + nInSensorNo := "cInBG3660", + stInOutSensor := "DB_Inputs".Sensors["cInBG3660"]); + // Pin Abfrage (KR-M1202 ) Block 1.2.4 + #fbSensorInput(stInSensorHW := "BG3661", + nInSensorNo := "cInBG3661", + stInOutSensor := "DB_Inputs".Sensors["cInBG3661"]); + // Prüfung MT Pos.1 (KR-K1202 Einfahrt Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3662", + nInSensorNo := "cInBG3662", + stInOutSensor := "DB_Inputs".Sensors["cInBG3662"]); + // Stausensor Str.2 (M1202) + #fbSensorInput(stInSensorHW := "BG3663", + nInSensorNo := "cInBG3663", + stInOutSensor := "DB_Inputs".Sensors["cInBG3663"]); + // in Separator 1 (ILS-CV M1208) + #fbSensorInput(stInSensorHW := "BG3664", + nInSensorNo := "cInBG3664", + stInOutSensor := "DB_Inputs".Sensors["cInBG3664"]); + // Stausensor Str.1 (KR-M1208) + #fbSensorInput(stInSensorHW := "BG3665", + nInSensorNo := "cInBG3665", + stInOutSensor := "DB_Inputs".Sensors["cInBG3665"]); + // Sensor Förderer voll (ILS-CV M1208) + #fbSensorInput(stInSensorHW := "BG3666", + nInSensorNo := "cInBG3666", + stInOutSensor := "DB_Inputs".Sensors["cInBG3666"]); + // Prüfung MT Pos.2 (KR-K1202 Einfahrt Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3667", + nInSensorNo := "cInBG3667", + stInOutSensor := "DB_Inputs".Sensors["cInBG3667"]); + // Prüfung MT Pos.3 (KR-K1202 Einfahrt Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3670", + nInSensorNo := "cInBG3670", + stInOutSensor := "DB_Inputs".Sensors["cInBG3670"]); + // Prüfung MT Pos.4 (KR-K1202 Einfahrt Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3671", + nInSensorNo := "cInBG3671", + stInOutSensor := "DB_Inputs".Sensors["cInBG3671"]); + // Stausensor Str.1 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3690", + nInSensorNo := "cInBG3690", + stInOutSensor := "DB_Inputs".Sensors["cInBG3690"]); + // Stausensor Str.2 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3691", + nInSensorNo := "cInBG3691", + stInOutSensor := "DB_Inputs".Sensors["cInBG3691"]); + // Stausensor Str.3 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3692", + nInSensorNo := "cInBG3692", + stInOutSensor := "DB_Inputs".Sensors["cInBG3692"]); + // Stausensor Str.4 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3693", + nInSensorNo := "cInBG3693", + stInOutSensor := "DB_Inputs".Sensors["cInBG3693"]); + // Stausensor Str.5 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3694", + nInSensorNo := "cInBG3694", + stInOutSensor := "DB_Inputs".Sensors["cInBG3694"]); + // Stausensor Str.6 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3695", + nInSensorNo := "cInBG3695", + stInOutSensor := "DB_Inputs".Sensors["cInBG3695"]); + // Stausensor Str.7 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3696", + nInSensorNo := "cInBG3696", + stInOutSensor := "DB_Inputs".Sensors["cInBG3696"]); + // Stausensor Str.8 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3697", + nInSensorNo := "cInBG3697", + stInOutSensor := "DB_Inputs".Sensors["cInBG3697"]); + // Stausensor Str.9 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3700", + nInSensorNo := "cInBG3700", + stInOutSensor := "DB_Inputs".Sensors["cInBG3700"]); + // Stausensor Str.10 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3701", + nInSensorNo := "cInBG3701", + stInOutSensor := "DB_Inputs".Sensors["cInBG3701"]); + // Stausensor Str.11 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3702", + nInSensorNo := "cInBG3702", + stInOutSensor := "DB_Inputs".Sensors["cInBG3702"]); + // Stausensor Str.12 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3703", + nInSensorNo := "cInBG3703", + stInOutSensor := "DB_Inputs".Sensors["cInBG3703"]); + // Stausensor Str.13 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3704", + nInSensorNo := "cInBG3704", + stInOutSensor := "DB_Inputs".Sensors["cInBG3704"]); + // in Separator 1 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3720", + nInSensorNo := "cInBG3720", + stInOutSensor := "DB_Inputs".Sensors["cInBG3720"]); + // Staumelder, Einfahrt (ILS-CV M1205) + #fbSensorInput(stInSensorHW := "BG3721", + nInSensorNo := "cInBG3721", + stInOutSensor := "DB_Inputs".Sensors["cInBG3721"]); + // Stausensor 1 (KR-M1203 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3722", + nInSensorNo := "cInBG3722", + stInOutSensor := "DB_Inputs".Sensors["cInBG3722"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1205) + #fbSensorInput(stInSensorHW := "BG3723", + nInSensorNo := "cInBG3723", + stInOutSensor := "DB_Inputs".Sensors["cInBG3723"]); + // in Separator 2 (ILS-CV M1205) + #fbSensorInput(stInSensorHW := "BG3724", + nInSensorNo := "cInBG3724", + stInOutSensor := "DB_Inputs".Sensors["cInBG3724"]); + // in Separator (KR-M1203) + #fbSensorInput(stInSensorHW := "BG3725", + nInSensorNo := "cInBG3725", + stInOutSensor := "DB_Inputs".Sensors["cInBG3725"]); + // MT in Position (ILS-CV M1205) + #fbSensorInput(stInSensorHW := "BG3727", + nInSensorNo := "cInBG3727", + stInOutSensor := "DB_Inputs".Sensors["cInBG3727"]); + // in Separator 1 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3750", + nInSensorNo := "cInBG3750", + stInOutSensor := "DB_Inputs".Sensors["cInBG3750"]); + // in Separator 2 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3751", + nInSensorNo := "cInBG3751", + stInOutSensor := "DB_Inputs".Sensors["cInBG3751"]); + // in Separator 3 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3752", + nInSensorNo := "cInBG3752", + stInOutSensor := "DB_Inputs".Sensors["cInBG3752"]); + // in Separator 4 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3753", + nInSensorNo := "cInBG3753", + stInOutSensor := "DB_Inputs".Sensors["cInBG3753"]); + // in Separator 5 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3754", + nInSensorNo := "cInBG3754", + stInOutSensor := "DB_Inputs".Sensors["cInBG3754"]); + // in Separator 6 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3755", + nInSensorNo := "cInBG3755", + stInOutSensor := "DB_Inputs".Sensors["cInBG3755"]); + // in Separator 7 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3756", + nInSensorNo := "cInBG3756", + stInOutSensor := "DB_Inputs".Sensors["cInBG3756"]); + // in Separator 8 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3757", + nInSensorNo := "cInBG3757", + stInOutSensor := "DB_Inputs".Sensors["cInBG3757"]); + // in Separator 9 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3760", + nInSensorNo := "cInBG3760", + stInOutSensor := "DB_Inputs".Sensors["cInBG3760"]); + // in Separator 10 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3761", + nInSensorNo := "cInBG3761", + stInOutSensor := "DB_Inputs".Sensors["cInBG3761"]); + // in Separator 11 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3762", + nInSensorNo := "cInBG3762", + stInOutSensor := "DB_Inputs".Sensors["cInBG3762"]); + // in Separator 12 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3763", + nInSensorNo := "cInBG3763", + stInOutSensor := "DB_Inputs".Sensors["cInBG3763"]); + // in Separator 13 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3764", + nInSensorNo := "cInBG3764", + stInOutSensor := "DB_Inputs".Sensors["cInBG3764"]); + // in Separator 14 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3765", + nInSensorNo := "cInBG3765", + stInOutSensor := "DB_Inputs".Sensors["cInBG3765"]); + // in Separator 15 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3766", + nInSensorNo := "cInBG3766", + stInOutSensor := "DB_Inputs".Sensors["cInBG3766"]); + // in Separator 16 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3767", + nInSensorNo := "cInBG3767", + stInOutSensor := "DB_Inputs".Sensors["cInBG3767"]); + // in Separator 17 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3770", + nInSensorNo := "cInBG3770", + stInOutSensor := "DB_Inputs".Sensors["cInBG3770"]); + // in Separator 18 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3771", + nInSensorNo := "cInBG3771", + stInOutSensor := "DB_Inputs".Sensors["cInBG3771"]); + // In Separator 19 (Block 1.2.1) + #fbSensorInput(stInSensorHW := "BG3772", + nInSensorNo := "cInBG3772", + stInOutSensor := "DB_Inputs".Sensors["cInBG3772"]); + // in Separator 1 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3780", + nInSensorNo := "cInBG3780", + stInOutSensor := "DB_Inputs".Sensors["cInBG3780"]); + // Staumelder, Einfahrt (ILS-CV M1206) + #fbSensorInput(stInSensorHW := "BG3781", + nInSensorNo := "cInBG3781", + stInOutSensor := "DB_Inputs".Sensors["cInBG3781"]); + // Stausensor 1 (KR-M1203 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3782", + nInSensorNo := "cInBG3782", + stInOutSensor := "DB_Inputs".Sensors["cInBG3782"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1206) + #fbSensorInput(stInSensorHW := "BG3783", + nInSensorNo := "cInBG3783", + stInOutSensor := "DB_Inputs".Sensors["cInBG3783"]); + // in Separator 2 (ILS-CV M1206) + #fbSensorInput(stInSensorHW := "BG3784", + nInSensorNo := "cInBG3784", + stInOutSensor := "DB_Inputs".Sensors["cInBG3784"]); + // Stausensor 3 (KR-M1203) + #fbSensorInput(stInSensorHW := "BG3785", + nInSensorNo := "cInBG3785", + stInOutSensor := "DB_Inputs".Sensors["cInBG3785"]); + // Rad dreht (KR-M1203) + #fbSensorInput(stInSensorHW := "BG3786", + nInSensorNo := "cInBG3786", + stInOutSensor := "DB_Inputs".Sensors["cInBG3786"]); + // MT in Position (ILS-CV M1206) + #fbSensorInput(stInSensorHW := "BG3787", + nInSensorNo := "cInBG3787", + stInOutSensor := "DB_Inputs".Sensors["cInBG3787"]); + // in Separator 1 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3810", + nInSensorNo := "cInBG3810", + stInOutSensor := "DB_Inputs".Sensors["cInBG3810"]); + // in Separator 2 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3811", + nInSensorNo := "cInBG3811", + stInOutSensor := "DB_Inputs".Sensors["cInBG3811"]); + // in Separator 3 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3812", + nInSensorNo := "cInBG3812", + stInOutSensor := "DB_Inputs".Sensors["cInBG3812"]); + // in Separator 4 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3813", + nInSensorNo := "cInBG3813", + stInOutSensor := "DB_Inputs".Sensors["cInBG3813"]); + // in Separator 5 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3814", + nInSensorNo := "cInBG3814", + stInOutSensor := "DB_Inputs".Sensors["cInBG3814"]); + // in Separator 6 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3815", + nInSensorNo := "cInBG3815", + stInOutSensor := "DB_Inputs".Sensors["cInBG3815"]); + // in Separator 7 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3816", + nInSensorNo := "cInBG3816", + stInOutSensor := "DB_Inputs".Sensors["cInBG3816"]); + // in Separator 8 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3817", + nInSensorNo := "cInBG3817", + stInOutSensor := "DB_Inputs".Sensors["cInBG3817"]); + // in Separator 9 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3820", + nInSensorNo := "cInBG3820", + stInOutSensor := "DB_Inputs".Sensors["cInBG3820"]); + // in Separator 10 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3821", + nInSensorNo := "cInBG3821", + stInOutSensor := "DB_Inputs".Sensors["cInBG3821"]); + // in Separator 11 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3822", + nInSensorNo := "cInBG3822", + stInOutSensor := "DB_Inputs".Sensors["cInBG3822"]); + // in Separator 12 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3823", + nInSensorNo := "cInBG3823", + stInOutSensor := "DB_Inputs".Sensors["cInBG3823"]); + // in Separator 13 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3824", + nInSensorNo := "cInBG3824", + stInOutSensor := "DB_Inputs".Sensors["cInBG3824"]); + // in Separator 14 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3825", + nInSensorNo := "cInBG3825", + stInOutSensor := "DB_Inputs".Sensors["cInBG3825"]); + // in Separator 15 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3826", + nInSensorNo := "cInBG3826", + stInOutSensor := "DB_Inputs".Sensors["cInBG3826"]); + // in Separator 16 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3827", + nInSensorNo := "cInBG3827", + stInOutSensor := "DB_Inputs".Sensors["cInBG3827"]); + // in Separator 17 (Block 1.2.2) + #fbSensorInput(stInSensorHW := "BG3830", + nInSensorNo := "cInBG3830", + stInOutSensor := "DB_Inputs".Sensors["cInBG3830"]); + // in Separator 1 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3840", + nInSensorNo := "cInBG3840", + stInOutSensor := "DB_Inputs".Sensors["cInBG3840"]); + // Staumelder, Einfahrt (ILS-CV M1207 Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3841", + nInSensorNo := "cInBG3841", + stInOutSensor := "DB_Inputs".Sensors["cInBG3841"]); + // Stausensor 1 (KR-M1204 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3842", + nInSensorNo := "cInBG3842", + stInOutSensor := "DB_Inputs".Sensors["cInBG3842"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1207) + #fbSensorInput(stInSensorHW := "BG3843", + nInSensorNo := "cInBG3843", + stInOutSensor := "DB_Inputs".Sensors["cInBG3843"]); + // in Separator 2 (ILS-CV M1207) + #fbSensorInput(stInSensorHW := "BG3844", + nInSensorNo := "cInBG3844", + stInOutSensor := "DB_Inputs".Sensors["cInBG3844"]); + // Stausensor (ILS-CV-M1204) + #fbSensorInput(stInSensorHW := "BG3845", + nInSensorNo := "cInBG3845", + stInOutSensor := "DB_Inputs".Sensors["cInBG3845"]); + // MT in Position (ILS-CV M1207) + #fbSensorInput(stInSensorHW := "BG3847", + nInSensorNo := "cInBG3847", + stInOutSensor := "DB_Inputs".Sensors["cInBG3847"]); + // in Separator 1 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3870", + nInSensorNo := "cInBG3870", + stInOutSensor := "DB_Inputs".Sensors["cInBG3870"]); + // in Separator 2 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3871", + nInSensorNo := "cInBG3871", + stInOutSensor := "DB_Inputs".Sensors["cInBG3871"]); + // in Separator 3 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3872", + nInSensorNo := "cInBG3872", + stInOutSensor := "DB_Inputs".Sensors["cInBG3872"]); + // in Separator 4 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3873", + nInSensorNo := "cInBG3873", + stInOutSensor := "DB_Inputs".Sensors["cInBG3873"]); + // in Separator 5 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3874", + nInSensorNo := "cInBG3874", + stInOutSensor := "DB_Inputs".Sensors["cInBG3874"]); + // in Separator 6 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3875", + nInSensorNo := "cInBG3875", + stInOutSensor := "DB_Inputs".Sensors["cInBG3875"]); + // in Separator 7 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3876", + nInSensorNo := "cInBG3876", + stInOutSensor := "DB_Inputs".Sensors["cInBG3876"]); + // in Separator 8 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3877", + nInSensorNo := "cInBG3877", + stInOutSensor := "DB_Inputs".Sensors["cInBG3877"]); + // in Separator 9 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3880", + nInSensorNo := "cInBG3880", + stInOutSensor := "DB_Inputs".Sensors["cInBG3880"]); + // in Separator 10 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3881", + nInSensorNo := "cInBG3881", + stInOutSensor := "DB_Inputs".Sensors["cInBG3881"]); + // in Separator 11 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3882", + nInSensorNo := "cInBG3882", + stInOutSensor := "DB_Inputs".Sensors["cInBG3882"]); + // in Separator 12 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3883", + nInSensorNo := "cInBG3883", + stInOutSensor := "DB_Inputs".Sensors["cInBG3883"]); + // in Separator 13 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3884", + nInSensorNo := "cInBG3884", + stInOutSensor := "DB_Inputs".Sensors["cInBG3884"]); + // in Separator 14 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3885", + nInSensorNo := "cInBG3885", + stInOutSensor := "DB_Inputs".Sensors["cInBG3885"]); + // in Separator 15 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3886", + nInSensorNo := "cInBG3886", + stInOutSensor := "DB_Inputs".Sensors["cInBG3886"]); + // in Separator 16 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3887", + nInSensorNo := "cInBG3887", + stInOutSensor := "DB_Inputs".Sensors["cInBG3887"]); + // in Separator 17 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3890", + nInSensorNo := "cInBG3890", + stInOutSensor := "DB_Inputs".Sensors["cInBG3890"]); + // in Separator 18 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3891", + nInSensorNo := "cInBG3891", + stInOutSensor := "DB_Inputs".Sensors["cInBG3891"]); + // in Separator 19 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3892", + nInSensorNo := "cInBG3892", + stInOutSensor := "DB_Inputs".Sensors["cInBG3892"]); + // in Separator 20 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3893", + nInSensorNo := "cInBG3893", + stInOutSensor := "DB_Inputs".Sensors["cInBG3893"]); + // in Separator 21 (Block 1.2.3) + #fbSensorInput(stInSensorHW := "BG3894", + nInSensorNo := "cInBG3894", + stInOutSensor := "DB_Inputs".Sensors["cInBG3894"]); + // in Separator 1 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3900", + nInSensorNo := "cInBG3900", + stInOutSensor := "DB_Inputs".Sensors["cInBG3900"]); + // Staumelder, Einfahrt (ILS-CV M1208) + #fbSensorInput(stInSensorHW := "BG3901", + nInSensorNo := "cInBG3901", + stInOutSensor := "DB_Inputs".Sensors["cInBG3901"]); + // Stausensor 1 (KR-M1204 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3902", + nInSensorNo := "cInBG3902", + stInOutSensor := "DB_Inputs".Sensors["cInBG3902"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1208) + #fbSensorInput(stInSensorHW := "BG3903", + nInSensorNo := "cInBG3903", + stInOutSensor := "DB_Inputs".Sensors["cInBG3903"]); + // in Separator 2 (ILS-CV M1208) + #fbSensorInput(stInSensorHW := "BG3904", + nInSensorNo := "cInBG3904", + stInOutSensor := "DB_Inputs".Sensors["cInBG3904"]); + // in Separator 3 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3905", + nInSensorNo := "cInBG3905", + stInOutSensor := "DB_Inputs".Sensors["cInBG3905"]); + // Stausensor 1 (M1204) + #fbSensorInput(stInSensorHW := "BG3906", + nInSensorNo := "cInBG3906", + stInOutSensor := "DB_Inputs".Sensors["cInBG3906"]); + // MT in Position (ILS-CV M1208) + #fbSensorInput(stInSensorHW := "BG3907", + nInSensorNo := "cInBG3907", + stInOutSensor := "DB_Inputs".Sensors["cInBG3907"]); + // Stausensor 2 (M2209) + #fbSensorInput(stInSensorHW := "BG3910", + nInSensorNo := "cInBG3910", + stInOutSensor := "DB_Inputs".Sensors["cInBG3910"]); + // Rad dreht (KR-M1204) + #fbSensorInput(stInSensorHW := "BG3911", + nInSensorNo := "cInBG3911", + stInOutSensor := "DB_Inputs".Sensors["cInBG3911"]); + // Stausensor (KR-M1204) + #fbSensorInput(stInSensorHW := "BG3912", + nInSensorNo := "cInBG3912", + stInOutSensor := "DB_Inputs".Sensors["cInBG3912"]); + // in Separator 1 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3930", + nInSensorNo := "cInBG3930", + stInOutSensor := "DB_Inputs".Sensors["cInBG3930"]); + // in Separator 2 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3931", + nInSensorNo := "cInBG3931", + stInOutSensor := "DB_Inputs".Sensors["cInBG3931"]); + // in Separator 3 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3932", + nInSensorNo := "cInBG3932", + stInOutSensor := "DB_Inputs".Sensors["cInBG3932"]); + // in Separator 4 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3933", + nInSensorNo := "cInBG3933", + stInOutSensor := "DB_Inputs".Sensors["cInBG3933"]); + // in Separator 5 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3934", + nInSensorNo := "cInBG3934", + stInOutSensor := "DB_Inputs".Sensors["cInBG3934"]); + // in Separator 6 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3935", + nInSensorNo := "cInBG3935", + stInOutSensor := "DB_Inputs".Sensors["cInBG3935"]); + // in Separator 7 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3936", + nInSensorNo := "cInBG3936", + stInOutSensor := "DB_Inputs".Sensors["cInBG3936"]); + // in Separator 8 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3937", + nInSensorNo := "cInBG3937", + stInOutSensor := "DB_Inputs".Sensors["cInBG3937"]); + // in Separator 9 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3940", + nInSensorNo := "cInBG3940", + stInOutSensor := "DB_Inputs".Sensors["cInBG3940"]); + // in Separator 10 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3941", + nInSensorNo := "cInBG3941", + stInOutSensor := "DB_Inputs".Sensors["cInBG3941"]); + // in Separator 11 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3942", + nInSensorNo := "cInBG3942", + stInOutSensor := "DB_Inputs".Sensors["cInBG3942"]); + // in Separator 12 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3943", + nInSensorNo := "cInBG3943", + stInOutSensor := "DB_Inputs".Sensors["cInBG3943"]); + // in Separator 13 (Block 1.2.4) + #fbSensorInput(stInSensorHW := "BG3944", + nInSensorNo := "cInBG3944", + stInOutSensor := "DB_Inputs".Sensors["cInBG3944"]); + // in Separator 1 (ILS-CV M1305) + #fbSensorInput(stInSensorHW := "BG3960", + nInSensorNo := "cInBG3960", + stInOutSensor := "DB_Inputs".Sensors["cInBG3960"]); + // Staumelder, Einfahrt (ILS-CV M1305) + #fbSensorInput(stInSensorHW := "BG3961", + nInSensorNo := "cInBG3961", + stInOutSensor := "DB_Inputs".Sensors["cInBG3961"]); + // Stausensor 1 (KR-M1301 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3962", + nInSensorNo := "cInBG3962", + stInOutSensor := "DB_Inputs".Sensors["cInBG3962"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1305) + #fbSensorInput(stInSensorHW := "BG3963", + nInSensorNo := "cInBG3963", + stInOutSensor := "DB_Inputs".Sensors["cInBG3963"]); + // in Separator 2 (ILS-CV M1305) + #fbSensorInput(stInSensorHW := "BG3964", + nInSensorNo := "cInBG3964", + stInOutSensor := "DB_Inputs".Sensors["cInBG3964"]); + // in Separator (KR-M1301) + #fbSensorInput(stInSensorHW := "BG3965", + nInSensorNo := "cInBG3965", + stInOutSensor := "DB_Inputs".Sensors["cInBG3965"]); + // MT in Position (ILS-CV M1305) + #fbSensorInput(stInSensorHW := "BG3967", + nInSensorNo := "cInBG3967", + stInOutSensor := "DB_Inputs".Sensors["cInBG3967"]); + // in Separator 1 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG3990", + nInSensorNo := "cInBG3990", + stInOutSensor := "DB_Inputs".Sensors["cInBG3990"]); + // in Separator 2 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG3991", + nInSensorNo := "cInBG3991", + stInOutSensor := "DB_Inputs".Sensors["cInBG3991"]); + // in Separator 3 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG3992", + nInSensorNo := "cInBG3992", + stInOutSensor := "DB_Inputs".Sensors["cInBG3992"]); + // in Separator 4 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG3993", + nInSensorNo := "cInBG3993", + stInOutSensor := "DB_Inputs".Sensors["cInBG3993"]); + // in Separator 5 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG3994", + nInSensorNo := "cInBG3994", + stInOutSensor := "DB_Inputs".Sensors["cInBG3994"]); + // in Separator 6 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG3995", + nInSensorNo := "cInBG3995", + stInOutSensor := "DB_Inputs".Sensors["cInBG3995"]); + // in Separator 7 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG3996", + nInSensorNo := "cInBG3996", + stInOutSensor := "DB_Inputs".Sensors["cInBG3996"]); + // in Separator 8 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG3997", + nInSensorNo := "cInBG3997", + stInOutSensor := "DB_Inputs".Sensors["cInBG3997"]); + // in Separator 9 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4000", + nInSensorNo := "cInBG4000", + stInOutSensor := "DB_Inputs".Sensors["cInBG4000"]); + // in Separator 10 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4001", + nInSensorNo := "cInBG4001", + stInOutSensor := "DB_Inputs".Sensors["cInBG4001"]); + // in Separator 11 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4002", + nInSensorNo := "cInBG4002", + stInOutSensor := "DB_Inputs".Sensors["cInBG4002"]); + // in Separator 12 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4003", + nInSensorNo := "cInBG4003", + stInOutSensor := "DB_Inputs".Sensors["cInBG4003"]); + // in Separator 13 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4004", + nInSensorNo := "cInBG4004", + stInOutSensor := "DB_Inputs".Sensors["cInBG4004"]); + // in Separator 14 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4005", + nInSensorNo := "cInBG4005", + stInOutSensor := "DB_Inputs".Sensors["cInBG4005"]); + // in Separator 15 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4006", + nInSensorNo := "cInBG4006", + stInOutSensor := "DB_Inputs".Sensors["cInBG4006"]); + // in Separator 16 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4007", + nInSensorNo := "cInBG4007", + stInOutSensor := "DB_Inputs".Sensors["cInBG4007"]); + // in Separator 17 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4010", + nInSensorNo := "cInBG4010", + stInOutSensor := "DB_Inputs".Sensors["cInBG4010"]); + // in Separator 18 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4011", + nInSensorNo := "cInBG4011", + stInOutSensor := "DB_Inputs".Sensors["cInBG4011"]); + // In Separator 19 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4012", + nInSensorNo := "cInBG4012", + stInOutSensor := "DB_Inputs".Sensors["cInBG4012"]); + // in Separator 1 (ILS-KR M1301) + #fbSensorInput(stInSensorHW := "BG4020", + nInSensorNo := "cInBG4020", + stInOutSensor := "DB_Inputs".Sensors["cInBG4020"]); + // Staumelder, Einfahrt (ILS-CV M1306) + #fbSensorInput(stInSensorHW := "BG4021", + nInSensorNo := "cInBG4021", + stInOutSensor := "DB_Inputs".Sensors["cInBG4021"]); + // Stausensor 1 (KR-M1301 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG4022", + nInSensorNo := "cInBG4022", + stInOutSensor := "DB_Inputs".Sensors["cInBG4022"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1306) + #fbSensorInput(stInSensorHW := "BG4023", + nInSensorNo := "cInBG4023", + stInOutSensor := "DB_Inputs".Sensors["cInBG4023"]); + // in Separator 2 (ILS-CV M1306) + #fbSensorInput(stInSensorHW := "BG4024", + nInSensorNo := "cInBG4024", + stInOutSensor := "DB_Inputs".Sensors["cInBG4024"]); + // Stausensor 3 (KR-M1301) + #fbSensorInput(stInSensorHW := "BG4025", + nInSensorNo := "cInBG4025", + stInOutSensor := "DB_Inputs".Sensors["cInBG4025"]); + // Rad dreht (KR-M1301) + #fbSensorInput(stInSensorHW := "BG4026", + nInSensorNo := "cInBG4026", + stInOutSensor := "DB_Inputs".Sensors["cInBG4026"]); + // MT in Position (ILS-CV M1306) + #fbSensorInput(stInSensorHW := "BG4027", + nInSensorNo := "cInBG4027", + stInOutSensor := "DB_Inputs".Sensors["cInBG4027"]); + // in Separator 1 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4050", + nInSensorNo := "cInBG4050", + stInOutSensor := "DB_Inputs".Sensors["cInBG4050"]); + // in Separator 2 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4051", + nInSensorNo := "cInBG4051", + stInOutSensor := "DB_Inputs".Sensors["cInBG4051"]); + // in Separator 3 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4052", + nInSensorNo := "cInBG4052", + stInOutSensor := "DB_Inputs".Sensors["cInBG4052"]); + // in Separator 4 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4053", + nInSensorNo := "cInBG4053", + stInOutSensor := "DB_Inputs".Sensors["cInBG4053"]); + // in Separator 5 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4054", + nInSensorNo := "cInBG4054", + stInOutSensor := "DB_Inputs".Sensors["cInBG4054"]); + // in Separator 6 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4055", + nInSensorNo := "cInBG4055", + stInOutSensor := "DB_Inputs".Sensors["cInBG4055"]); + // in Separator 7 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4056", + nInSensorNo := "cInBG4056", + stInOutSensor := "DB_Inputs".Sensors["cInBG4056"]); + // in Separator 8 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4057", + nInSensorNo := "cInBG4057", + stInOutSensor := "DB_Inputs".Sensors["cInBG4057"]); + // in Separator 9 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4060", + nInSensorNo := "cInBG4060", + stInOutSensor := "DB_Inputs".Sensors["cInBG4060"]); + // in Separator 10 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4061", + nInSensorNo := "cInBG4061", + stInOutSensor := "DB_Inputs".Sensors["cInBG4061"]); + // in Separator 11 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4062", + nInSensorNo := "cInBG4062", + stInOutSensor := "DB_Inputs".Sensors["cInBG4062"]); + // in Separator 12 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4063", + nInSensorNo := "cInBG4063", + stInOutSensor := "DB_Inputs".Sensors["cInBG4063"]); + // in Separator 13 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4064", + nInSensorNo := "cInBG4064", + stInOutSensor := "DB_Inputs".Sensors["cInBG4064"]); + // in Separator 14 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4065", + nInSensorNo := "cInBG4065", + stInOutSensor := "DB_Inputs".Sensors["cInBG4065"]); + // in Separator 15 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4066", + nInSensorNo := "cInBG4066", + stInOutSensor := "DB_Inputs".Sensors["cInBG4066"]); + // in Separator 16 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4067", + nInSensorNo := "cInBG4067", + stInOutSensor := "DB_Inputs".Sensors["cInBG4067"]); + // in Separator 17 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4070", + nInSensorNo := "cInBG4070", + stInOutSensor := "DB_Inputs".Sensors["cInBG4070"]); + // in Separator 1 (ILS-CV M1302) + #fbSensorInput(stInSensorHW := "BG4080", + nInSensorNo := "cInBG4080", + stInOutSensor := "DB_Inputs".Sensors["cInBG4080"]); + // Staumelder, Einfahrt (ILS-CV M1307) + #fbSensorInput(stInSensorHW := "BG4081", + nInSensorNo := "cInBG4081", + stInOutSensor := "DB_Inputs".Sensors["cInBG4081"]); + // Stausensor 1 (KR-M1302 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG4082", + nInSensorNo := "cInBG4082", + stInOutSensor := "DB_Inputs".Sensors["cInBG4082"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1307) + #fbSensorInput(stInSensorHW := "BG4083", + nInSensorNo := "cInBG4083", + stInOutSensor := "DB_Inputs".Sensors["cInBG4083"]); + // in Separator 2 (ILS-CV M1307) + #fbSensorInput(stInSensorHW := "BG4084", + nInSensorNo := "cInBG4084", + stInOutSensor := "DB_Inputs".Sensors["cInBG4084"]); + // in Separator 3 (ILS-KR-M1302) + #fbSensorInput(stInSensorHW := "BG4085", + nInSensorNo := "cInBG4085", + stInOutSensor := "DB_Inputs".Sensors["cInBG4085"]); + // MT in Position (ILS-CV M1307) + #fbSensorInput(stInSensorHW := "BG4087", + nInSensorNo := "cInBG4087", + stInOutSensor := "DB_Inputs".Sensors["cInBG4087"]); + // Stausensor (ILS-KR-M1302) + #fbSensorInput(stInSensorHW := "BG4090", + nInSensorNo := "cInBG4090", + stInOutSensor := "DB_Inputs".Sensors["cInBG4090"]); + // Stausensor (ILS-KR-M2309) + #fbSensorInput(stInSensorHW := "BG4091", + nInSensorNo := "cInBG4091", + stInOutSensor := "DB_Inputs".Sensors["cInBG4091"]); + // in Separator 1 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4110", + nInSensorNo := "cInBG4110", + stInOutSensor := "DB_Inputs".Sensors["cInBG4110"]); + // in Separator 2 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4111", + nInSensorNo := "cInBG4111", + stInOutSensor := "DB_Inputs".Sensors["cInBG4111"]); + // in Separator 3 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4112", + nInSensorNo := "cInBG4112", + stInOutSensor := "DB_Inputs".Sensors["cInBG4112"]); + // in Separator 4 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4113", + nInSensorNo := "cInBG4113", + stInOutSensor := "DB_Inputs".Sensors["cInBG4113"]); + // in Separator 5 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4114", + nInSensorNo := "cInBG4114", + stInOutSensor := "DB_Inputs".Sensors["cInBG4114"]); + // in Separator 6 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4115", + nInSensorNo := "cInBG4115", + stInOutSensor := "DB_Inputs".Sensors["cInBG4115"]); + // in Separator 7 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4116", + nInSensorNo := "cInBG4116", + stInOutSensor := "DB_Inputs".Sensors["cInBG4116"]); + // in Separator 8 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4117", + nInSensorNo := "cInBG4117", + stInOutSensor := "DB_Inputs".Sensors["cInBG4117"]); + // in Separator 9 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4120", + nInSensorNo := "cInBG4120", + stInOutSensor := "DB_Inputs".Sensors["cInBG4120"]); + // in Separator 10 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4121", + nInSensorNo := "cInBG4121", + stInOutSensor := "DB_Inputs".Sensors["cInBG4121"]); + // in Separator 11 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4122", + nInSensorNo := "cInBG4122", + stInOutSensor := "DB_Inputs".Sensors["cInBG4122"]); + // in Separator 12 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4123", + nInSensorNo := "cInBG4123", + stInOutSensor := "DB_Inputs".Sensors["cInBG4123"]); + // in Separator 13 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4124", + nInSensorNo := "cInBG4124", + stInOutSensor := "DB_Inputs".Sensors["cInBG4124"]); + // in Separator 14 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4125", + nInSensorNo := "cInBG4125", + stInOutSensor := "DB_Inputs".Sensors["cInBG4125"]); + // in Separator 15 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4126", + nInSensorNo := "cInBG4126", + stInOutSensor := "DB_Inputs".Sensors["cInBG4126"]); + // in Separator 16 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4127", + nInSensorNo := "cInBG4127", + stInOutSensor := "DB_Inputs".Sensors["cInBG4127"]); + // in Separator 17 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4130", + nInSensorNo := "cInBG4130", + stInOutSensor := "DB_Inputs".Sensors["cInBG4130"]); + // in Separator 18 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4131", + nInSensorNo := "cInBG4131", + stInOutSensor := "DB_Inputs".Sensors["cInBG4131"]); + // in Separator 19 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4132", + nInSensorNo := "cInBG4132", + stInOutSensor := "DB_Inputs".Sensors["cInBG4132"]); + // in Separator 20 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4133", + nInSensorNo := "cInBG4133", + stInOutSensor := "DB_Inputs".Sensors["cInBG4133"]); + // in Separator 21 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4134", + nInSensorNo := "cInBG4134", + stInOutSensor := "DB_Inputs".Sensors["cInBG4134"]); + // in Separator 1 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4140", + nInSensorNo := "cInBG4140", + stInOutSensor := "DB_Inputs".Sensors["cInBG4140"]); + // Staumelder, Einfahrt (ILS-CV M1308) + #fbSensorInput(stInSensorHW := "BG4141", + nInSensorNo := "cInBG4141", + stInOutSensor := "DB_Inputs".Sensors["cInBG4141"]); + // Stausensor 1 (KR-M1302 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG4142", + nInSensorNo := "cInBG4142", + stInOutSensor := "DB_Inputs".Sensors["cInBG4142"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1308) + #fbSensorInput(stInSensorHW := "BG4143", + nInSensorNo := "cInBG4143", + stInOutSensor := "DB_Inputs".Sensors["cInBG4143"]); + // in Separator 2 (ILS-CV M1308) + #fbSensorInput(stInSensorHW := "BG4144", + nInSensorNo := "cInBG4144", + stInOutSensor := "DB_Inputs".Sensors["cInBG4144"]); + // MT in Position (ILS-CV M1308) + #fbSensorInput(stInSensorHW := "BG4147", + nInSensorNo := "cInBG4147", + stInOutSensor := "DB_Inputs".Sensors["cInBG4147"]); + // Rad dreht (KR-M1302) + #fbSensorInput(stInSensorHW := "BG4150", + nInSensorNo := "cInBG4150", + stInOutSensor := "DB_Inputs".Sensors["cInBG4150"]); + // in Separator 1 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4170", + nInSensorNo := "cInBG4170", + stInOutSensor := "DB_Inputs".Sensors["cInBG4170"]); + // in Separator 2 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4171", + nInSensorNo := "cInBG4171", + stInOutSensor := "DB_Inputs".Sensors["cInBG4171"]); + // in Separator 3 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4172", + nInSensorNo := "cInBG4172", + stInOutSensor := "DB_Inputs".Sensors["cInBG4172"]); + // in Separator 4 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4173", + nInSensorNo := "cInBG4173", + stInOutSensor := "DB_Inputs".Sensors["cInBG4173"]); + // in Separator 5 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4174", + nInSensorNo := "cInBG4174", + stInOutSensor := "DB_Inputs".Sensors["cInBG4174"]); + // in Separator 6 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4175", + nInSensorNo := "cInBG4175", + stInOutSensor := "DB_Inputs".Sensors["cInBG4175"]); + // in Separator 7 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4176", + nInSensorNo := "cInBG4176", + stInOutSensor := "DB_Inputs".Sensors["cInBG4176"]); + // in Separator 8 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4177", + nInSensorNo := "cInBG4177", + stInOutSensor := "DB_Inputs".Sensors["cInBG4177"]); + // in Separator 9 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4180", + nInSensorNo := "cInBG4180", + stInOutSensor := "DB_Inputs".Sensors["cInBG4180"]); + // in Separator 10 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4181", + nInSensorNo := "cInBG4181", + stInOutSensor := "DB_Inputs".Sensors["cInBG4181"]); + // in Separator 11 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4182", + nInSensorNo := "cInBG4182", + stInOutSensor := "DB_Inputs".Sensors["cInBG4182"]); + // in Separator 12 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4183", + nInSensorNo := "cInBG4183", + stInOutSensor := "DB_Inputs".Sensors["cInBG4183"]); + // in Separator 13 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4184", + nInSensorNo := "cInBG4184", + stInOutSensor := "DB_Inputs".Sensors["cInBG4184"]); + // in Separator 2 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4200", + nInSensorNo := "cInBG4200", + stInOutSensor := "DB_Inputs".Sensors["cInBG4200"]); + // Pin Abfrage (KR-M1303 ) Block 1.3.1 + #fbSensorInput(stInSensorHW := "BG4201", + nInSensorNo := "cInBG4201", + stInOutSensor := "DB_Inputs".Sensors["cInBG4201"]); + // Prüfung MT Pos.1 (KR-K1303 Einfahrt Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4202", + nInSensorNo := "cInBG4202", + stInOutSensor := "DB_Inputs".Sensors["cInBG4202"]); + // Stausensor (KR-M1303) + #fbSensorInput(stInSensorHW := "BG4203", + nInSensorNo := "cInBG4203", + stInOutSensor := "DB_Inputs".Sensors["cInBG4203"]); + // in Separator 1 (ILS-CV 1305) + #fbSensorInput(stInSensorHW := "BG4204", + nInSensorNo := "cInBG4204", + stInOutSensor := "DB_Inputs".Sensors["cInBG4204"]); + // Stausensor Str.1 (KR-K1305) + #fbSensorInput(stInSensorHW := "BG4205", + nInSensorNo := "cInBG4205", + stInOutSensor := "DB_Inputs".Sensors["cInBG4205"]); + // Sensor Förderer voll (ILS-CV 1305) + #fbSensorInput(stInSensorHW := "BG4206", + nInSensorNo := "cInBG4206", + stInOutSensor := "DB_Inputs".Sensors["cInBG4206"]); + // Prüfung MT Pos.2 (KR-K1303 Einfahrt Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4207", + nInSensorNo := "cInBG4207", + stInOutSensor := "DB_Inputs".Sensors["cInBG4207"]); + // Prüfung MT Pos.3 (KR-K1303 Einfahrt Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4210", + nInSensorNo := "cInBG4210", + stInOutSensor := "DB_Inputs".Sensors["cInBG4210"]); + // Prüfung MT Pos.4 (KR-K1303 Einfahrt Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4211", + nInSensorNo := "cInBG4211", + stInOutSensor := "DB_Inputs".Sensors["cInBG4211"]); + // Prüfung MT Pos.5 (KR-K1303 Einfahrt Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4212", + nInSensorNo := "cInBG4212", + stInOutSensor := "DB_Inputs".Sensors["cInBG4212"]); + // Stausensor Str.1 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4230", + nInSensorNo := "cInBG4230", + stInOutSensor := "DB_Inputs".Sensors["cInBG4230"]); + // Stausensor Str.2 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4231", + nInSensorNo := "cInBG4231", + stInOutSensor := "DB_Inputs".Sensors["cInBG4231"]); + // Stausensor Str.3 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4232", + nInSensorNo := "cInBG4232", + stInOutSensor := "DB_Inputs".Sensors["cInBG4232"]); + // Stausensor Str.4 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4233", + nInSensorNo := "cInBG4233", + stInOutSensor := "DB_Inputs".Sensors["cInBG4233"]); + // Stausensor Str.5 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4234", + nInSensorNo := "cInBG4234", + stInOutSensor := "DB_Inputs".Sensors["cInBG4234"]); + // Stausensor Str.6 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4235", + nInSensorNo := "cInBG4235", + stInOutSensor := "DB_Inputs".Sensors["cInBG4235"]); + // Stausensor Str.7 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4236", + nInSensorNo := "cInBG4236", + stInOutSensor := "DB_Inputs".Sensors["cInBG4236"]); + // Stausensor Str.8 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4237", + nInSensorNo := "cInBG4237", + stInOutSensor := "DB_Inputs".Sensors["cInBG4237"]); + // Stausensor Str.9 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4240", + nInSensorNo := "cInBG4240", + stInOutSensor := "DB_Inputs".Sensors["cInBG4240"]); + // Stausensor Str.10 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4241", + nInSensorNo := "cInBG4241", + stInOutSensor := "DB_Inputs".Sensors["cInBG4241"]); + // Stausensor Str.11 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4242", + nInSensorNo := "cInBG4242", + stInOutSensor := "DB_Inputs".Sensors["cInBG4242"]); + // Stausensor Str.12 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4243", + nInSensorNo := "cInBG4243", + stInOutSensor := "DB_Inputs".Sensors["cInBG4243"]); + // Stausensor Str.13 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4244", + nInSensorNo := "cInBG4244", + stInOutSensor := "DB_Inputs".Sensors["cInBG4244"]); + // Stausensor Str.14 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4245", + nInSensorNo := "cInBG4245", + stInOutSensor := "DB_Inputs".Sensors["cInBG4245"]); + // Stausensor Str.15 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4246", + nInSensorNo := "cInBG4246", + stInOutSensor := "DB_Inputs".Sensors["cInBG4246"]); + // Stausensor Str.16 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4247", + nInSensorNo := "cInBG4247", + stInOutSensor := "DB_Inputs".Sensors["cInBG4247"]); + // Stausensor Str.17 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4250", + nInSensorNo := "cInBG4250", + stInOutSensor := "DB_Inputs".Sensors["cInBG4250"]); + // Stausensor Str.18 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4251", + nInSensorNo := "cInBG4251", + stInOutSensor := "DB_Inputs".Sensors["cInBG4251"]); + // Stausensor Str.19 (Block 1.3.1) + #fbSensorInput(stInSensorHW := "BG4252", + nInSensorNo := "cInBG4252", + stInOutSensor := "DB_Inputs".Sensors["cInBG4252"]); + // in Separator 2 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4260", + nInSensorNo := "cInBG4260", + stInOutSensor := "DB_Inputs".Sensors["cInBG4260"]); + // Pin Abfrage (KR-M1303 ) Block 1.3.2 + #fbSensorInput(stInSensorHW := "BG4261", + nInSensorNo := "cInBG4261", + stInOutSensor := "DB_Inputs".Sensors["cInBG4261"]); + // Prüfung MT Pos.1 (KR-K1303 Einfahrt Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4262", + nInSensorNo := "cInBG4262", + stInOutSensor := "DB_Inputs".Sensors["cInBG4262"]); + // Stausensor (KR-M1303) + #fbSensorInput(stInSensorHW := "BG4263", + nInSensorNo := "cInBG4263", + stInOutSensor := "DB_Inputs".Sensors["cInBG4263"]); + // in Separator 1 (ILS-CV M1306) + #fbSensorInput(stInSensorHW := "BG4264", + nInSensorNo := "cInBG4264", + stInOutSensor := "DB_Inputs".Sensors["cInBG4264"]); + // Stausensor Str.1 (ILS-CV M1306) + #fbSensorInput(stInSensorHW := "BG4265", + nInSensorNo := "cInBG4265", + stInOutSensor := "DB_Inputs".Sensors["cInBG4265"]); + // Sensor Förderer voll (ILS-CV M1306) + #fbSensorInput(stInSensorHW := "BG4266", + nInSensorNo := "cInBG4266", + stInOutSensor := "DB_Inputs".Sensors["cInBG4266"]); + // Prüfung MT Pos.2 (KR-K1303 Einfahrt Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4267", + nInSensorNo := "cInBG4267", + stInOutSensor := "DB_Inputs".Sensors["cInBG4267"]); + // Prüfung MT Pos.3 (KR-K1303 Einfahrt Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4270", + nInSensorNo := "cInBG4270", + stInOutSensor := "DB_Inputs".Sensors["cInBG4270"]); + // Prüfung MT Pos.4 (KR-K1303 Einfahrt Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4271", + nInSensorNo := "cInBG4271", + stInOutSensor := "DB_Inputs".Sensors["cInBG4271"]); + // Prüfung MT Pos.5 (KR-K1303 Einfahrt Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4272", + nInSensorNo := "cInBG4272", + stInOutSensor := "DB_Inputs".Sensors["cInBG4272"]); + // Stausensor MT vor Pinband (KR-K1303) Block 1.3.2 + #fbSensorInput(stInSensorHW := "BG4273", + nInSensorNo := "cInBG4273", + stInOutSensor := "DB_Inputs".Sensors["cInBG4273"]); + // Stausensor Str.1 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4290", + nInSensorNo := "cInBG4290", + stInOutSensor := "DB_Inputs".Sensors["cInBG4290"]); + // Stausensor Str.2 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4291", + nInSensorNo := "cInBG4291", + stInOutSensor := "DB_Inputs".Sensors["cInBG4291"]); + // Stausensor Str.3 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4292", + nInSensorNo := "cInBG4292", + stInOutSensor := "DB_Inputs".Sensors["cInBG4292"]); + // Stausensor Str.4 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4293", + nInSensorNo := "cInBG4293", + stInOutSensor := "DB_Inputs".Sensors["cInBG4293"]); + // Stausensor Str.5 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4294", + nInSensorNo := "cInBG4294", + stInOutSensor := "DB_Inputs".Sensors["cInBG4294"]); + // Stausensor Str.6 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4295", + nInSensorNo := "cInBG4295", + stInOutSensor := "DB_Inputs".Sensors["cInBG4295"]); + // Stausensor Str.7 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4296", + nInSensorNo := "cInBG4296", + stInOutSensor := "DB_Inputs".Sensors["cInBG4296"]); + // Stausensor Str.8 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4297", + nInSensorNo := "cInBG4297", + stInOutSensor := "DB_Inputs".Sensors["cInBG4297"]); + // Stausensor Str.9 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4300", + nInSensorNo := "cInBG4300", + stInOutSensor := "DB_Inputs".Sensors["cInBG4300"]); + // Stausensor Str.10 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4301", + nInSensorNo := "cInBG4301", + stInOutSensor := "DB_Inputs".Sensors["cInBG4301"]); + // Stausensor Str.11 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4302", + nInSensorNo := "cInBG4302", + stInOutSensor := "DB_Inputs".Sensors["cInBG4302"]); + // Stausensor Str.12 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4303", + nInSensorNo := "cInBG4303", + stInOutSensor := "DB_Inputs".Sensors["cInBG4303"]); + // Stausensor Str.13 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4304", + nInSensorNo := "cInBG4304", + stInOutSensor := "DB_Inputs".Sensors["cInBG4304"]); + // Stausensor Str.14 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4305", + nInSensorNo := "cInBG4305", + stInOutSensor := "DB_Inputs".Sensors["cInBG4305"]); + // Stausensor Str.15 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4306", + nInSensorNo := "cInBG4306", + stInOutSensor := "DB_Inputs".Sensors["cInBG4306"]); + // Stausensor Str.16 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4307", + nInSensorNo := "cInBG4307", + stInOutSensor := "DB_Inputs".Sensors["cInBG4307"]); + // Stausensor Str.17 (Block 1.3.2) + #fbSensorInput(stInSensorHW := "BG4310", + nInSensorNo := "cInBG4310", + stInOutSensor := "DB_Inputs".Sensors["cInBG4310"]); + // in Separator 2 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4320", + nInSensorNo := "cInBG4320", + stInOutSensor := "DB_Inputs".Sensors["cInBG4320"]); + // Pin Abfrage (KR-M1304) Block 1.3.3 + #fbSensorInput(stInSensorHW := "BG4321", + nInSensorNo := "cInBG4321", + stInOutSensor := "DB_Inputs".Sensors["cInBG4321"]); + // Prüfung MT Pos.1 (KR-K1304 Einfahrt Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4322", + nInSensorNo := "cInBG4322", + stInOutSensor := "DB_Inputs".Sensors["cInBG4322"]); + // Stausensor (KR-M1304) + #fbSensorInput(stInSensorHW := "BG4323", + nInSensorNo := "cInBG4323", + stInOutSensor := "DB_Inputs".Sensors["cInBG4323"]); + // in Separator 1 (ILS-CV M1307) + #fbSensorInput(stInSensorHW := "BG4324", + nInSensorNo := "cInBG4324", + stInOutSensor := "DB_Inputs".Sensors["cInBG4324"]); + // Stausensor Str.1 (ILS-CV M1307) + #fbSensorInput(stInSensorHW := "BG4325", + nInSensorNo := "cInBG4325", + stInOutSensor := "DB_Inputs".Sensors["cInBG4325"]); + // Sensor Förderer voll (ILS-CV 1307) + #fbSensorInput(stInSensorHW := "BG4326", + nInSensorNo := "cInBG4326", + stInOutSensor := "DB_Inputs".Sensors["cInBG4326"]); + // Prüfung MT Pos.2 (KR-K1304 Einfahrt Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4327", + nInSensorNo := "cInBG4327", + stInOutSensor := "DB_Inputs".Sensors["cInBG4327"]); + // Prüfung MT Pos.3 (KR-K1304 Einfahrt Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4330", + nInSensorNo := "cInBG4330", + stInOutSensor := "DB_Inputs".Sensors["cInBG4330"]); + // Prüfung MT Pos.4 (KR-K1304 Einfahrt Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4331", + nInSensorNo := "cInBG4331", + stInOutSensor := "DB_Inputs".Sensors["cInBG4331"]); + // Prüfung MT Pos.5 (KR-K1304 Einfahrt Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4332", + nInSensorNo := "cInBG4332", + stInOutSensor := "DB_Inputs".Sensors["cInBG4332"]); + // Prüfung MT Pos.6 (KR-K1304 Einfahrt Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4333", + nInSensorNo := "cInBG4333", + stInOutSensor := "DB_Inputs".Sensors["cInBG4333"]); + // in Separator (ILS-CV-M1309) + #fbSensorInput(stInSensorHW := "BG4334", + nInSensorNo := "cInBG4334", + stInOutSensor := "DB_Inputs".Sensors["cInBG4334"]); + // Stausensor (M1309) + #fbSensorInput(stInSensorHW := "BG4335", + nInSensorNo := "cInBG4335", + stInOutSensor := "DB_Inputs".Sensors["cInBG4335"]); + // Sensor Förderer voll (ILS-CV M1309) + #fbSensorInput(stInSensorHW := "BG4336", + nInSensorNo := "cInBG4336", + stInOutSensor := "DB_Inputs".Sensors["cInBG4336"]); + // in Separator 1 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4337", + nInSensorNo := "cInBG4337", + stInOutSensor := "DB_Inputs".Sensors["cInBG4337"]); + // Stausensor 1 (KR-M1304) + #fbSensorInput(stInSensorHW := "BG4340", + nInSensorNo := "cInBG4340", + stInOutSensor := "DB_Inputs".Sensors["cInBG4340"]); + // in Separator (ILS-CV M1309) + #fbSensorInput(stInSensorHW := "BG4342", + nInSensorNo := "cInBG4342", + stInOutSensor := "DB_Inputs".Sensors["cInBG4342"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1309) + #fbSensorInput(stInSensorHW := "BG4343", + nInSensorNo := "cInBG4343", + stInOutSensor := "DB_Inputs".Sensors["cInBG4343"]); + // MT in Position (ILS-CV M1309) + #fbSensorInput(stInSensorHW := "BG4344", + nInSensorNo := "cInBG4344", + stInOutSensor := "DB_Inputs".Sensors["cInBG4344"]); + // Stausensor Str.1 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4350", + nInSensorNo := "cInBG4350", + stInOutSensor := "DB_Inputs".Sensors["cInBG4350"]); + // Stausensor Str.2 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4351", + nInSensorNo := "cInBG4351", + stInOutSensor := "DB_Inputs".Sensors["cInBG4351"]); + // Stausensor Str.3 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4352", + nInSensorNo := "cInBG4352", + stInOutSensor := "DB_Inputs".Sensors["cInBG4352"]); + // Stausensor Str.4 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4353", + nInSensorNo := "cInBG4353", + stInOutSensor := "DB_Inputs".Sensors["cInBG4353"]); + // Stausensor Str.5 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4354", + nInSensorNo := "cInBG4354", + stInOutSensor := "DB_Inputs".Sensors["cInBG4354"]); + // Stausensor Str.6 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4355", + nInSensorNo := "cInBG4355", + stInOutSensor := "DB_Inputs".Sensors["cInBG4355"]); + // Stausensor Str.7 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4356", + nInSensorNo := "cInBG4356", + stInOutSensor := "DB_Inputs".Sensors["cInBG4356"]); + // Stausensor Str.8 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4357", + nInSensorNo := "cInBG4357", + stInOutSensor := "DB_Inputs".Sensors["cInBG4357"]); + // Stausensor Str.9 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4360", + nInSensorNo := "cInBG4360", + stInOutSensor := "DB_Inputs".Sensors["cInBG4360"]); + // Stausensor Str.10 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4361", + nInSensorNo := "cInBG4361", + stInOutSensor := "DB_Inputs".Sensors["cInBG4361"]); + // Stausensor Str.11 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4362", + nInSensorNo := "cInBG4362", + stInOutSensor := "DB_Inputs".Sensors["cInBG4362"]); + // Stausensor Str.12 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4363", + nInSensorNo := "cInBG4363", + stInOutSensor := "DB_Inputs".Sensors["cInBG4363"]); + // Stausensor Str.13 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4364", + nInSensorNo := "cInBG4364", + stInOutSensor := "DB_Inputs".Sensors["cInBG4364"]); + // Stausensor Str.14 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4365", + nInSensorNo := "cInBG4365", + stInOutSensor := "DB_Inputs".Sensors["cInBG4365"]); + // Stausensor Str.15 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4366", + nInSensorNo := "cInBG4366", + stInOutSensor := "DB_Inputs".Sensors["cInBG4366"]); + // Stausensor Str.16 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4367", + nInSensorNo := "cInBG4367", + stInOutSensor := "DB_Inputs".Sensors["cInBG4367"]); + // Stausensor Str.17 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4370", + nInSensorNo := "cInBG4370", + stInOutSensor := "DB_Inputs".Sensors["cInBG4370"]); + // Stausensor Str.18 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4371", + nInSensorNo := "cInBG4371", + stInOutSensor := "DB_Inputs".Sensors["cInBG4371"]); + // Stausensor Str.19 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4372", + nInSensorNo := "cInBG4372", + stInOutSensor := "DB_Inputs".Sensors["cInBG4372"]); + // Stausensor Str.20 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4373", + nInSensorNo := "cInBG4373", + stInOutSensor := "DB_Inputs".Sensors["cInBG4373"]); + // Stausensor Str.21 (Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4374", + nInSensorNo := "cInBG4374", + stInOutSensor := "DB_Inputs".Sensors["cInBG4374"]); + // Stausensor MT vor Pinband (KR-K1304) Block 1.3.3) + #fbSensorInput(stInSensorHW := "BG4375", + nInSensorNo := "cInBG4375", + stInOutSensor := "DB_Inputs".Sensors["cInBG4375"]); + // in Separator 2 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4380", + nInSensorNo := "cInBG4380", + stInOutSensor := "DB_Inputs".Sensors["cInBG4380"]); + // Pin Abfrage (KR-M1304) Block 1.3.4 + #fbSensorInput(stInSensorHW := "BG4381", + nInSensorNo := "cInBG4381", + stInOutSensor := "DB_Inputs".Sensors["cInBG4381"]); + // Prüfung MT Pos.1 (KR-K1304 Einfahrt Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4382", + nInSensorNo := "cInBG4382", + stInOutSensor := "DB_Inputs".Sensors["cInBG4382"]); + // Stausensor (KR-M1304) + #fbSensorInput(stInSensorHW := "BG4383", + nInSensorNo := "cInBG4383", + stInOutSensor := "DB_Inputs".Sensors["cInBG4383"]); + // in Separator 1 (ILS-CV M1308) + #fbSensorInput(stInSensorHW := "BG4384", + nInSensorNo := "cInBG4384", + stInOutSensor := "DB_Inputs".Sensors["cInBG4384"]); + // Stausensor Str.1 (ILS-CV M1308) + #fbSensorInput(stInSensorHW := "BG4385", + nInSensorNo := "cInBG4385", + stInOutSensor := "DB_Inputs".Sensors["cInBG4385"]); + // Sensor Förderer voll (ILS-CV M1308) + #fbSensorInput(stInSensorHW := "BG4386", + nInSensorNo := "cInBG4386", + stInOutSensor := "DB_Inputs".Sensors["cInBG4386"]); + // Prüfung MT Pos.2 (KR-K1304 Einfahrt Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4387", + nInSensorNo := "cInBG4387", + stInOutSensor := "DB_Inputs".Sensors["cInBG4387"]); + // Prüfung MT Pos.3 (KR-K1304 Einfahrt Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4390", + nInSensorNo := "cInBG4390", + stInOutSensor := "DB_Inputs".Sensors["cInBG4390"]); + // Prüfung MT Pos.4 (KR-K1304 Einfahrt Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4391", + nInSensorNo := "cInBG4391", + stInOutSensor := "DB_Inputs".Sensors["cInBG4391"]); + // Stausensor Str.1 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4410", + nInSensorNo := "cInBG4410", + stInOutSensor := "DB_Inputs".Sensors["cInBG4410"]); + // Stausensor Str.2 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4411", + nInSensorNo := "cInBG4411", + stInOutSensor := "DB_Inputs".Sensors["cInBG4411"]); + // Stausensor Str.3 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4412", + nInSensorNo := "cInBG4412", + stInOutSensor := "DB_Inputs".Sensors["cInBG4412"]); + // Stausensor Str.4 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4413", + nInSensorNo := "cInBG4413", + stInOutSensor := "DB_Inputs".Sensors["cInBG4413"]); + // Stausensor Str.5 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4414", + nInSensorNo := "cInBG4414", + stInOutSensor := "DB_Inputs".Sensors["cInBG4414"]); + // Stausensor Str.6 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4415", + nInSensorNo := "cInBG4415", + stInOutSensor := "DB_Inputs".Sensors["cInBG4415"]); + // Stausensor Str.7 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4416", + nInSensorNo := "cInBG4416", + stInOutSensor := "DB_Inputs".Sensors["cInBG4416"]); + // Stausensor Str.8 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4417", + nInSensorNo := "cInBG4417", + stInOutSensor := "DB_Inputs".Sensors["cInBG4417"]); + // Stausensor Str.9 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4420", + nInSensorNo := "cInBG4420", + stInOutSensor := "DB_Inputs".Sensors["cInBG4420"]); + // Stausensor Str.10 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4421", + nInSensorNo := "cInBG4421", + stInOutSensor := "DB_Inputs".Sensors["cInBG4421"]); + // Stausensor Str.11 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4422", + nInSensorNo := "cInBG4422", + stInOutSensor := "DB_Inputs".Sensors["cInBG4422"]); + // Stausensor Str.12 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4423", + nInSensorNo := "cInBG4423", + stInOutSensor := "DB_Inputs".Sensors["cInBG4423"]); + // Stausensor Str.13 (Block 1.3.4) + #fbSensorInput(stInSensorHW := "BG4424", + nInSensorNo := "cInBG4424", + stInOutSensor := "DB_Inputs".Sensors["cInBG4424"]); + // in Separator 2 (KR-M1100) + #fbSensorInput(stInSensorHW := "BG4440", + nInSensorNo := "cInBG4440", + stInOutSensor := "DB_Inputs".Sensors["cInBG4440"]); + // Stausensor (ILS-KR M1100) + #fbSensorInput(stInSensorHW := "BG4442", + nInSensorNo := "cInBG4442", + stInOutSensor := "DB_Inputs".Sensors["cInBG4442"]); + // Stausensor 7 (ILS-KR M1100) + #fbSensorInput(stInSensorHW := "BG4443", + nInSensorNo := "cInBG4443", + stInOutSensor := "DB_Inputs".Sensors["cInBG4443"]); + // Stausensor (ILS-CV M0520) + #fbSensorInput(stInSensorHW := "BG4444", + nInSensorNo := "cInBG4444", + stInOutSensor := "DB_Inputs".Sensors["cInBG4444"]); + // in Separator 1 (ILS-CV M1401) + #fbSensorInput(stInSensorHW := "BG4445", + nInSensorNo := "cInBG4445", + stInOutSensor := "DB_Inputs".Sensors["cInBG4445"]); + // Sensor Förderer voll (ILS-CV M1401) + #fbSensorInput(stInSensorHW := "BG4446", + nInSensorNo := "cInBG4446", + stInOutSensor := "DB_Inputs".Sensors["cInBG4446"]); + // Stausensor (ILS-CV M1401) + #fbSensorInput(stInSensorHW := "BG4447", + nInSensorNo := "cInBG4447", + stInOutSensor := "DB_Inputs".Sensors["cInBG4447"]); + // in Separator 3 (KR-M1100) + #fbSensorInput(stInSensorHW := "BG4451", + nInSensorNo := "cInBG4451", + stInOutSensor := "DB_Inputs".Sensors["cInBG4451"]); + // Stausensor 6 (ILS-KR M1100) + #fbSensorInput(stInSensorHW := "BG4453", + nInSensorNo := "cInBG4453", + stInOutSensor := "DB_Inputs".Sensors["cInBG4453"]); + // Stausensor 8 (ILS-KR M1100) + #fbSensorInput(stInSensorHW := "BG4454", + nInSensorNo := "cInBG4454", + stInOutSensor := "DB_Inputs".Sensors["cInBG4454"]); + // Stausensor (ILS-CV M0510) + #fbSensorInput(stInSensorHW := "BG4455", + nInSensorNo := "cInBG4455", + stInOutSensor := "DB_Inputs".Sensors["cInBG4455"]); + // in Separator 4 (KR-M1100) + #fbSensorInput(stInSensorHW := "BG4456", + nInSensorNo := "cInBG4456", + stInOutSensor := "DB_Inputs".Sensors["cInBG4456"]); + // Stausensor nach Separator MB4456 (ILS-KR M1100) + #fbSensorInput(stInSensorHW := "BG4457", + nInSensorNo := "cInBG4457", + stInOutSensor := "DB_Inputs".Sensors["cInBG4457"]); + // in Separator 2 (ILS-CV M1401) + #fbSensorInput(stInSensorHW := "BG4460", + nInSensorNo := "cInBG4460", + stInOutSensor := "DB_Inputs".Sensors["cInBG4460"]); + // MT in Position (ILS-CV M1401) + #fbSensorInput(stInSensorHW := "BG4461", + nInSensorNo := "cInBG4461", + stInOutSensor := "DB_Inputs".Sensors["cInBG4461"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1401) + #fbSensorInput(stInSensorHW := "BG4462", + nInSensorNo := "cInBG4462", + stInOutSensor := "DB_Inputs".Sensors["cInBG4462"]); + // in Separator (ILS-CV M1100) + #fbSensorInput(stInSensorHW := "BG4500", + nInSensorNo := "cInBG4500", + stInOutSensor := "DB_Inputs".Sensors["cInBG4500"]); + // Stausensor 10 (KR-M1100) + #fbSensorInput(stInSensorHW := "BG4502", + nInSensorNo := "cInBG4502", + stInOutSensor := "DB_Inputs".Sensors["cInBG4502"]); + // Stausensor 11 (KR-M1100) + #fbSensorInput(stInSensorHW := "BG4503", + nInSensorNo := "cInBG4503", + stInOutSensor := "DB_Inputs".Sensors["cInBG4503"]); + // Stausensor 12 (KR-M1100) + #fbSensorInput(stInSensorHW := "BG4504", + nInSensorNo := "cInBG4504", + stInOutSensor := "DB_Inputs".Sensors["cInBG4504"]); + // in Separator 3 (KR-M1100) + #fbSensorInput(stInSensorHW := "BG4505", + nInSensorNo := "cInBG4505", + stInOutSensor := "DB_Inputs".Sensors["cInBG4505"]); + // Stausensor 2 (KR-M1100) + #fbSensorInput(stInSensorHW := "BG4507", + nInSensorNo := "cInBG4507", + stInOutSensor := "DB_Inputs".Sensors["cInBG4507"]); + // Rad dreht (KR-M1110) + #fbSensorInput(stInSensorHW := "BG4510", + nInSensorNo := "cInBG4510", + stInOutSensor := "DB_Inputs".Sensors["cInBG4510"]); + // in Separator (KR-M1100) + #fbSensorInput(stInSensorHW := "BG4512", + nInSensorNo := "cInBG4512", + stInOutSensor := "DB_Inputs".Sensors["cInBG4512"]); + // Stausensor 4 (CV-M1100) + #fbSensorInput(stInSensorHW := "BG4514", + nInSensorNo := "cInBG4514", + stInOutSensor := "DB_Inputs".Sensors["cInBG4514"]); + // Sensor Förderer voll (CV-M1501) + #fbSensorInput(stInSensorHW := "BG4520", + nInSensorNo := "cInBG4520", + stInOutSensor := "DB_Inputs".Sensors["cInBG4520"]); + // Stausensor (M1501) + #fbSensorInput(stInSensorHW := "BG4521", + nInSensorNo := "cInBG4521", + stInOutSensor := "DB_Inputs".Sensors["cInBG4521"]); + // in Separator (CV-M1501) + #fbSensorInput(stInSensorHW := "BG4522", + nInSensorNo := "cInBG4522", + stInOutSensor := "DB_Inputs".Sensors["cInBG4522"]); + // Sensor Förderer voll (CV-M1601) + #fbSensorInput(stInSensorHW := "BG4524", + nInSensorNo := "cInBG4524", + stInOutSensor := "DB_Inputs".Sensors["cInBG4524"]); + // Stausensor (CV-M1601) + #fbSensorInput(stInSensorHW := "BG4525", + nInSensorNo := "cInBG4525", + stInOutSensor := "DB_Inputs".Sensors["cInBG4525"]); + // in Separator (CV-M1601) + #fbSensorInput(stInSensorHW := "BG4526", + nInSensorNo := "cInBG4526", + stInOutSensor := "DB_Inputs".Sensors["cInBG4526"]); + // in Separator (ILS-CV M4701) + #fbSensorInput(stInSensorHW := "BG4530", + nInSensorNo := "cInBG4530", + stInOutSensor := "DB_Inputs".Sensors["cInBG4530"]); + // Abfrage Mitnehmerfinger in Position (CV M4701) + #fbSensorInput(stInSensorHW := "BG4531", + nInSensorNo := "cInBG4531", + stInOutSensor := "DB_Inputs".Sensors["cInBG4531"]); + // Stausensor (CV-M4701) + #fbSensorInput(stInSensorHW := "BG4532", + nInSensorNo := "cInBG4532", + stInOutSensor := "DB_Inputs".Sensors["cInBG4532"]); + // MT in Position (ILS-CV M4701) + #fbSensorInput(stInSensorHW := "BG4533", + nInSensorNo := "cInBG4533", + stInOutSensor := "DB_Inputs".Sensors["cInBG4533"]); + // Stausensor (ILS-CV M1801) + #fbSensorInput(stInSensorHW := "BG4534", + nInSensorNo := "cInBG4534", + stInOutSensor := "DB_Inputs".Sensors["cInBG4534"]); + // in Separator (ILS-CV M1801) + #fbSensorInput(stInSensorHW := "BG4535", + nInSensorNo := "cInBG4535", + stInOutSensor := "DB_Inputs".Sensors["cInBG4535"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1801) + #fbSensorInput(stInSensorHW := "BG4536", + nInSensorNo := "cInBG4536", + stInOutSensor := "DB_Inputs".Sensors["cInBG4536"]); + // MT in Position (ILS-CV M1801) + #fbSensorInput(stInSensorHW := "BG4537", + nInSensorNo := "cInBG4537", + stInOutSensor := "DB_Inputs".Sensors["cInBG4537"]); + // in Separator 2 (ILS-CV M1401) + #fbSensorInput(stInSensorHW := "BG4540", + nInSensorNo := "cInBG4540", + stInOutSensor := "DB_Inputs".Sensors["cInBG4540"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1501) + #fbSensorInput(stInSensorHW := "BG4541", + nInSensorNo := "cInBG4541", + stInOutSensor := "DB_Inputs".Sensors["cInBG4541"]); + // MT in Position (ILS-CV M1501) + #fbSensorInput(stInSensorHW := "BG4542", + nInSensorNo := "cInBG4542", + stInOutSensor := "DB_Inputs".Sensors["cInBG4542"]); + // in Separator 2 (ILS-CV M1401) + #fbSensorInput(stInSensorHW := "BG4543", + nInSensorNo := "cInBG4543", + stInOutSensor := "DB_Inputs".Sensors["cInBG4543"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M1601) + #fbSensorInput(stInSensorHW := "BG4544", + nInSensorNo := "cInBG4544", + stInOutSensor := "DB_Inputs".Sensors["cInBG4544"]); + // MT in Position (ILS-CV M1601) + #fbSensorInput(stInSensorHW := "BG4545", + nInSensorNo := "cInBG4545", + stInOutSensor := "DB_Inputs".Sensors["cInBG4545"]); + // Sensor Förderer voll (ILS-CV M1801) + #fbSensorInput(stInSensorHW := "BG4550", + nInSensorNo := "cInBG4550", + stInOutSensor := "DB_Inputs".Sensors["cInBG4550"]); + // Stausensor(ILS-CV M1801) + #fbSensorInput(stInSensorHW := "BG4551", + nInSensorNo := "cInBG4551", + stInOutSensor := "DB_Inputs".Sensors["cInBG4551"]); + // in Separator (ILS-CV M1801) + #fbSensorInput(stInSensorHW := "BG4552", + nInSensorNo := "cInBG4552", + stInOutSensor := "DB_Inputs".Sensors["cInBG4552"]); + // Sensor Förderer voll (ILS-CV 4701) + #fbSensorInput(stInSensorHW := "BG4553", + nInSensorNo := "cInBG4553", + stInOutSensor := "DB_Inputs".Sensors["cInBG4553"]); + // Stausensor(ILS-CV M4701) + #fbSensorInput(stInSensorHW := "BG4554", + nInSensorNo := "cInBG4554", + stInOutSensor := "DB_Inputs".Sensors["cInBG4554"]); + // in Separator (ILS-CV M4701) + #fbSensorInput(stInSensorHW := "BG4555", + nInSensorNo := "cInBG4555", + stInOutSensor := "DB_Inputs".Sensors["cInBG4555"]); +END_FUNCTION_BLOCK diff --git a/results/FB_CallSensors_skel_UH03.scl b/results/FB_CallSensors_skel_UH03.scl new file mode 100644 index 0000000..f74c56c --- /dev/null +++ b/results/FB_CallSensors_skel_UH03.scl @@ -0,0 +1,3806 @@ +FUNCTION_BLOCK "FB_CallSensors_skel_UH03" +{ S7_Optimized_Access := 'TRUE' } +VERSION : 0.1 +// AUTOMATISCH GENERIERT — create_skel.py (949 Sensoren) + VAR + fbSensorInput : "FB_SensorInput"; + END_VAR + +BEGIN + // DT Anlage Aus + #fbSensorInput(stInSensorHW := "SF0000", + nInSensorNo := "cInSF0000", + stInOutSensor := "DB_Inputs".Sensors["cInSF0000"]); + // LDT Anlage Ein + #fbSensorInput(stInSensorHW := "SF0001", + nInSensorNo := "cInSF0001", + stInOutSensor := "DB_Inputs".Sensors["cInSF0001"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0002", + nInSensorNo := "cInSF0002", + stInOutSensor := "DB_Inputs".Sensors["cInSF0002"]); + // DT Lampentest + #fbSensorInput(stInSensorHW := "SF0003", + nInSensorNo := "cInSF0003", + stInOutSensor := "DB_Inputs".Sensors["cInSF0003"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0004", + nInSensorNo := "cInBP0004", + stInOutSensor := "DB_Inputs".Sensors["cInBP0004"]); + // Phasenausfall 400V + #fbSensorInput(stInSensorHW := "DI0005", + nInSensorNo := "cInDI0005", + stInOutSensor := "DB_Inputs".Sensors["cInDI0005"]); + // Vorsicherung 400V UC031 + #fbSensorInput(stInSensorHW := "DI0006", + nInSensorNo := "cInDI0006", + stInOutSensor := "DB_Inputs".Sensors["cInDI0006"]); + // Vorsicherung 400V UC032 + #fbSensorInput(stInSensorHW := "DI0007", + nInSensorNo := "cInDI0007", + stInOutSensor := "DB_Inputs".Sensors["cInDI0007"]); + // Vorsicherung 400V UC033 + #fbSensorInput(stInSensorHW := "DI0010", + nInSensorNo := "cInDI0010", + stInOutSensor := "DB_Inputs".Sensors["cInDI0010"]); + // Vorsicherung 400V UC Reserve + #fbSensorInput(stInSensorHW := "DI0011", + nInSensorNo := "cInDI0011", + stInOutSensor := "DB_Inputs".Sensors["cInDI0011"]); + // Vorsicherung 400V UC Reserve + #fbSensorInput(stInSensorHW := "DI0012", + nInSensorNo := "cInDI0012", + stInOutSensor := "DB_Inputs".Sensors["cInDI0012"]); + // Feedback Hauptschütze aktiv + #fbSensorInput(stInSensorHW := "DI0013", + nInSensorNo := "cInDI0013", + stInOutSensor := "DB_Inputs".Sensors["cInDI0013"]); + // Feedback Koppelrelais E-Stop-IF (QA0660/QA0661) + #fbSensorInput(stInSensorHW := "DI0014", + nInSensorNo := "cInDI0014", + stInOutSensor := "DB_Inputs".Sensors["cInDI0014"]); + // Feedback Koppelrelais E-Stop-IF + #fbSensorInput(stInSensorHW := "DI0015", + nInSensorNo := "cInDI0015", + stInOutSensor := "DB_Inputs".Sensors["cInDI0015"]); + // Sicherungsautomatenfall + #fbSensorInput(stInSensorHW := "DI0016", + nInSensorNo := "cInDI0016", + stInOutSensor := "DB_Inputs".Sensors["cInDI0016"]); + // Vorsicherung 24V OK (FC021) + #fbSensorInput(stInSensorHW := "DI0021", + nInSensorNo := "cInDI0021", + stInOutSensor := "DB_Inputs".Sensors["cInDI0021"]); + // Vorsicherung 24V OK (FC022) + #fbSensorInput(stInSensorHW := "DI0022", + nInSensorNo := "cInDI0022", + stInOutSensor := "DB_Inputs".Sensors["cInDI0022"]); + // Vorsicherung 24V OK (FC023) + #fbSensorInput(stInSensorHW := "DI0023", + nInSensorNo := "cInDI0023", + stInOutSensor := "DB_Inputs".Sensors["cInDI0023"]); + // Vorsicherung 24V OK (FC024) + #fbSensorInput(stInSensorHW := "DI0024", + nInSensorNo := "cInDI0024", + stInOutSensor := "DB_Inputs".Sensors["cInDI0024"]); + // Vorsicherung 24V OK (FC025) + #fbSensorInput(stInSensorHW := "DI0025", + nInSensorNo := "cInDI0025", + stInOutSensor := "DB_Inputs".Sensors["cInDI0025"]); + // Vorsicherung 24V OK (FC026) + #fbSensorInput(stInSensorHW := "DI0026", + nInSensorNo := "cInDI0026", + stInOutSensor := "DB_Inputs".Sensors["cInDI0026"]); + // IF BMZ "fire alarm" 2 + #fbSensorInput(stInSensorHW := "DI0033", + nInSensorNo := "cInDI0033", + stInOutSensor := "DB_Inputs".Sensors["cInDI0033"]); + // IF BMZ "fire alarm" 1 + #fbSensorInput(stInSensorHW := "DI0034", + nInSensorNo := "cInDI0034", + stInOutSensor := "DB_Inputs".Sensors["cInDI0034"]); + // IF BST "No fire alarm" + #fbSensorInput(stInSensorHW := "DI0035", + nInSensorNo := "cInDI0035", + stInOutSensor := "DB_Inputs".Sensors["cInDI0035"]); + // IF BST "Non fault" + #fbSensorInput(stInSensorHW := "DI0036", + nInSensorNo := "cInDI0036", + stInOutSensor := "DB_Inputs".Sensors["cInDI0036"]); + // IF BST "FPC opened" + #fbSensorInput(stInSensorHW := "DI0037", + nInSensorNo := "cInDI0037", + stInOutSensor := "DB_Inputs".Sensors["cInDI0037"]); + // Bereichshalt UZ0301 + #fbSensorInput(stInSensorHW := "SF0040", + nInSensorNo := "cInSF0040", + stInOutSensor := "DB_Inputs".Sensors["cInSF0040"]); + // Reset UZ0301 + #fbSensorInput(stInSensorHW := "SF0041", + nInSensorNo := "cInSF0041", + stInOutSensor := "DB_Inputs".Sensors["cInSF0041"]); + // Bereichshalt UZ0302 + #fbSensorInput(stInSensorHW := "SF0042", + nInSensorNo := "cInSF0042", + stInOutSensor := "DB_Inputs".Sensors["cInSF0042"]); + // Reset UZ0302 + #fbSensorInput(stInSensorHW := "SF0043", + nInSensorNo := "cInSF0043", + stInOutSensor := "DB_Inputs".Sensors["cInSF0043"]); + // Bereichshalt UZ0303 + #fbSensorInput(stInSensorHW := "SF0044", + nInSensorNo := "cInSF0044", + stInOutSensor := "DB_Inputs".Sensors["cInSF0044"]); + // Reset UZ0303 + #fbSensorInput(stInSensorHW := "SF0045", + nInSensorNo := "cInSF0045", + stInOutSensor := "DB_Inputs".Sensors["cInSF0045"]); + // Bereichshalt UZ0304 + #fbSensorInput(stInSensorHW := "SF0046", + nInSensorNo := "cInSF0046", + stInOutSensor := "DB_Inputs".Sensors["cInSF0046"]); + // Reset UZ0304 + #fbSensorInput(stInSensorHW := "SF0047", + nInSensorNo := "cInSF0047", + stInOutSensor := "DB_Inputs".Sensors["cInSF0047"]); + // Bereichshalt UZ0305 + #fbSensorInput(stInSensorHW := "SF0050", + nInSensorNo := "cInSF0050", + stInOutSensor := "DB_Inputs".Sensors["cInSF0050"]); + // Reset UZ0305 + #fbSensorInput(stInSensorHW := "SF0051", + nInSensorNo := "cInSF0051", + stInOutSensor := "DB_Inputs".Sensors["cInSF0051"]); + // Bereichshalt UZ0306 + #fbSensorInput(stInSensorHW := "SF0052", + nInSensorNo := "cInSF0052", + stInOutSensor := "DB_Inputs".Sensors["cInSF0052"]); + // Reset UZ0306 + #fbSensorInput(stInSensorHW := "SF0053", + nInSensorNo := "cInSF0053", + stInOutSensor := "DB_Inputs".Sensors["cInSF0053"]); + // Bereichshalt UZ0307 + #fbSensorInput(stInSensorHW := "SF0054", + nInSensorNo := "cInSF0054", + stInOutSensor := "DB_Inputs".Sensors["cInSF0054"]); + // Reset UZ0307 + #fbSensorInput(stInSensorHW := "SF0055", + nInSensorNo := "cInSF0055", + stInOutSensor := "DB_Inputs".Sensors["cInSF0055"]); + // Bereichshalt UZ0308 + #fbSensorInput(stInSensorHW := "SF0056", + nInSensorNo := "cInSF0056", + stInOutSensor := "DB_Inputs".Sensors["cInSF0056"]); + // Reset UZ0308 + #fbSensorInput(stInSensorHW := "SF0057", + nInSensorNo := "cInSF0057", + stInOutSensor := "DB_Inputs".Sensors["cInSF0057"]); + // MSS ausgelöst FC0060 (KR-M2103) + #fbSensorInput(stInSensorHW := "FC0060", + nInSensorNo := "cInFC0060", + stInOutSensor := "DB_Inputs".Sensors["cInFC0060"]); + // MSS ausgelöst FC0061 (KR-M2104) + #fbSensorInput(stInSensorHW := "FC0061", + nInSensorNo := "cInFC0061", + stInOutSensor := "DB_Inputs".Sensors["cInFC0061"]); + // MSS ausgelöst FC0062 (KR-M2201) + #fbSensorInput(stInSensorHW := "FC0062", + nInSensorNo := "cInFC0062", + stInOutSensor := "DB_Inputs".Sensors["cInFC0062"]); + // MSS ausgelöst FC0063 (KR-M2202) + #fbSensorInput(stInSensorHW := "FC0063", + nInSensorNo := "cInFC0063", + stInOutSensor := "DB_Inputs".Sensors["cInFC0063"]); + // MSS ausgelöst FC0064 (CV-M2205) + #fbSensorInput(stInSensorHW := "FC0064", + nInSensorNo := "cInFC0064", + stInOutSensor := "DB_Inputs".Sensors["cInFC0064"]); + // MSS ausgelöst FC0065 (CV-M2206) + #fbSensorInput(stInSensorHW := "FC0065", + nInSensorNo := "cInFC0065", + stInOutSensor := "DB_Inputs".Sensors["cInFC0065"]); + // MSS ausgelöst FC0066 (CV-M2207) + #fbSensorInput(stInSensorHW := "FC0066", + nInSensorNo := "cInFC0066", + stInOutSensor := "DB_Inputs".Sensors["cInFC0066"]); + // MSS ausgelöst FC0067 (CV-M2208) + #fbSensorInput(stInSensorHW := "FC0067", + nInSensorNo := "cInFC0067", + stInOutSensor := "DB_Inputs".Sensors["cInFC0067"]); + // MSS ausgelöst FC0070 (CV-M2109) + #fbSensorInput(stInSensorHW := "FC0070", + nInSensorNo := "cInFC0070", + stInOutSensor := "DB_Inputs".Sensors["cInFC0070"]); + // MSS ausgelöst FC0071 (KR-M2110) + #fbSensorInput(stInSensorHW := "FC0071", + nInSensorNo := "cInFC0071", + stInOutSensor := "DB_Inputs".Sensors["cInFC0071"]); + // MSS ausgelöst FC0072 (KR-M2112) + #fbSensorInput(stInSensorHW := "FC0072", + nInSensorNo := "cInFC0072", + stInOutSensor := "DB_Inputs".Sensors["cInFC0072"]); + // MSS ausgelöst FC0073 (CV-M2111) + #fbSensorInput(stInSensorHW := "FC0073", + nInSensorNo := "cInFC0073", + stInOutSensor := "DB_Inputs".Sensors["cInFC0073"]); + // MSS ausgelöst FC0074 (CV-M4101) + #fbSensorInput(stInSensorHW := "FC0074", + nInSensorNo := "cInFC0074", + stInOutSensor := "DB_Inputs".Sensors["cInFC0074"]); + // MSS ausgelöst FC0075 (CV-M4201) + #fbSensorInput(stInSensorHW := "FC0075", + nInSensorNo := "cInFC0075", + stInOutSensor := "DB_Inputs".Sensors["cInFC0075"]); + // Bereichshalt UZ0309 + #fbSensorInput(stInSensorHW := "SF0080", + nInSensorNo := "cInSF0080", + stInOutSensor := "DB_Inputs".Sensors["cInSF0080"]); + // Reset UZ0309 + #fbSensorInput(stInSensorHW := "SF0081", + nInSensorNo := "cInSF0081", + stInOutSensor := "DB_Inputs".Sensors["cInSF0081"]); + // Bereichshalt UZ0310 + #fbSensorInput(stInSensorHW := "SF0082", + nInSensorNo := "cInSF0082", + stInOutSensor := "DB_Inputs".Sensors["cInSF0082"]); + // Reset UZ0310 + #fbSensorInput(stInSensorHW := "SF0083", + nInSensorNo := "cInSF0083", + stInOutSensor := "DB_Inputs".Sensors["cInSF0083"]); + // Bereichshalt UZ0311 + #fbSensorInput(stInSensorHW := "SF0084", + nInSensorNo := "cInSF0084", + stInOutSensor := "DB_Inputs".Sensors["cInSF0084"]); + // Reset UZ0311 + #fbSensorInput(stInSensorHW := "SF0085", + nInSensorNo := "cInSF0085", + stInOutSensor := "DB_Inputs".Sensors["cInSF0085"]); + // Bereichshalt UZ0312 + #fbSensorInput(stInSensorHW := "SF0086", + nInSensorNo := "cInSF0086", + stInOutSensor := "DB_Inputs".Sensors["cInSF0086"]); + // Reset UZ0312 + #fbSensorInput(stInSensorHW := "SF0087", + nInSensorNo := "cInSF0087", + stInOutSensor := "DB_Inputs".Sensors["cInSF0087"]); + // MSS ausgelöst FC0090 (CV-M4102) + #fbSensorInput(stInSensorHW := "FC0090", + nInSensorNo := "cInFC0090", + stInOutSensor := "DB_Inputs".Sensors["cInFC0090"]); + // MSS ausgelöst FC0091 (CV-M4202) + #fbSensorInput(stInSensorHW := "FC0091", + nInSensorNo := "cInFC0091", + stInOutSensor := "DB_Inputs".Sensors["cInFC0091"]); + // MSS ausgelöst FC0092 (CV-M4301) + #fbSensorInput(stInSensorHW := "FC0092", + nInSensorNo := "cInFC0092", + stInOutSensor := "DB_Inputs".Sensors["cInFC0092"]); + // MSS ausgelöst FC0093 (CV-M4401) + #fbSensorInput(stInSensorHW := "FC0093", + nInSensorNo := "cInFC0093", + stInOutSensor := "DB_Inputs".Sensors["cInFC0093"]); + // Meldekontakt 400V Motor+Bremse + #fbSensorInput(stInSensorHW := "DI0100", + nInSensorNo := "cInDI0100", + stInOutSensor := "DB_Inputs".Sensors["cInDI0100"]); + // Vorsicherung 24V OK (FC101) + #fbSensorInput(stInSensorHW := "DI0101", + nInSensorNo := "cInDI0101", + stInOutSensor := "DB_Inputs".Sensors["cInDI0101"]); + // Vorsicherung 24V OK (FC102) + #fbSensorInput(stInSensorHW := "DI0102", + nInSensorNo := "cInDI0102", + stInOutSensor := "DB_Inputs".Sensors["cInDI0102"]); + // Vorsicherung 24V OK (FC103) + #fbSensorInput(stInSensorHW := "DI0103", + nInSensorNo := "cInDI0103", + stInOutSensor := "DB_Inputs".Sensors["cInDI0103"]); + // Feedback Hauptschütze aktiv (QA0920/QA0921) + #fbSensorInput(stInSensorHW := "DI0106", + nInSensorNo := "cInDI0106", + stInOutSensor := "DB_Inputs".Sensors["cInDI0106"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0107", + nInSensorNo := "cInBP0107", + stInOutSensor := "DB_Inputs".Sensors["cInBP0107"]); + // Feedback Koppelrelais E-Stop-IF (QA0922/QA0923) + #fbSensorInput(stInSensorHW := "DI0114", + nInSensorNo := "cInDI0114", + stInOutSensor := "DB_Inputs".Sensors["cInDI0114"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0117", + nInSensorNo := "cInSF0117", + stInOutSensor := "DB_Inputs".Sensors["cInSF0117"]); + // Bereichshalt UZ3101 + #fbSensorInput(stInSensorHW := "SF0120", + nInSensorNo := "cInSF0120", + stInOutSensor := "DB_Inputs".Sensors["cInSF0120"]); + // Reset UZ3101 + #fbSensorInput(stInSensorHW := "SF0121", + nInSensorNo := "cInSF0121", + stInOutSensor := "DB_Inputs".Sensors["cInSF0121"]); + // Bereichshalt UZ3102 + #fbSensorInput(stInSensorHW := "SF0122", + nInSensorNo := "cInSF0122", + stInOutSensor := "DB_Inputs".Sensors["cInSF0122"]); + // Reset UZ3102 + #fbSensorInput(stInSensorHW := "SF0123", + nInSensorNo := "cInSF0123", + stInOutSensor := "DB_Inputs".Sensors["cInSF0123"]); + // Bereichshalt UZ3103 + #fbSensorInput(stInSensorHW := "SF0124", + nInSensorNo := "cInSF0124", + stInOutSensor := "DB_Inputs".Sensors["cInSF0124"]); + // Reset UZ3103 + #fbSensorInput(stInSensorHW := "SF0125", + nInSensorNo := "cInSF0125", + stInOutSensor := "DB_Inputs".Sensors["cInSF0125"]); + // Bereichshalt UZ3104 + #fbSensorInput(stInSensorHW := "SF0126", + nInSensorNo := "cInSF0126", + stInOutSensor := "DB_Inputs".Sensors["cInSF0126"]); + // Reset UZ3104 + #fbSensorInput(stInSensorHW := "SF0127", + nInSensorNo := "cInSF0127", + stInOutSensor := "DB_Inputs".Sensors["cInSF0127"]); + // MSS ausgelöst FC0140 (KR-M2101) + #fbSensorInput(stInSensorHW := "FC0140", + nInSensorNo := "cInFC0140", + stInOutSensor := "DB_Inputs".Sensors["cInFC0140"]); + // MSS ausgelöst FC0141 (KR-M2102) + #fbSensorInput(stInSensorHW := "FC0141", + nInSensorNo := "cInFC0141", + stInOutSensor := "DB_Inputs".Sensors["cInFC0141"]); + // MSS ausgelöst FC0142 (CV-M2105) + #fbSensorInput(stInSensorHW := "FC0142", + nInSensorNo := "cInFC0142", + stInOutSensor := "DB_Inputs".Sensors["cInFC0142"]); + // MSS ausgelöst FC0143 (CV-M2106) + #fbSensorInput(stInSensorHW := "FC0143", + nInSensorNo := "cInFC0143", + stInOutSensor := "DB_Inputs".Sensors["cInFC0143"]); + // MSS ausgelöst FC0144 (CV-M2107) + #fbSensorInput(stInSensorHW := "FC0144", + nInSensorNo := "cInFC0144", + stInOutSensor := "DB_Inputs".Sensors["cInFC0144"]); + // MSS ausgelöst FC0145 (CV-M2108) + #fbSensorInput(stInSensorHW := "FC0145", + nInSensorNo := "cInFC0145", + stInOutSensor := "DB_Inputs".Sensors["cInFC0145"]); + // Meldekontakt 400V Motor+Bremse + #fbSensorInput(stInSensorHW := "DI0160", + nInSensorNo := "cInDI0160", + stInOutSensor := "DB_Inputs".Sensors["cInDI0160"]); + // Vorsicherung 24V OK (FC161) + #fbSensorInput(stInSensorHW := "DI0161", + nInSensorNo := "cInDI0161", + stInOutSensor := "DB_Inputs".Sensors["cInDI0161"]); + // Vorsicherung 24V OK (FC162) + #fbSensorInput(stInSensorHW := "DI0162", + nInSensorNo := "cInDI0162", + stInOutSensor := "DB_Inputs".Sensors["cInDI0162"]); + // Vorsicherung 24V OK (FC163) + #fbSensorInput(stInSensorHW := "DI0163", + nInSensorNo := "cInDI0163", + stInOutSensor := "DB_Inputs".Sensors["cInDI0163"]); + // Vorsicherung 24V OK (FC164) + #fbSensorInput(stInSensorHW := "DI0164", + nInSensorNo := "cInDI0164", + stInOutSensor := "DB_Inputs".Sensors["cInDI0164"]); + // Vorsicherung 24V OK (FC165) + #fbSensorInput(stInSensorHW := "DI0165", + nInSensorNo := "cInDI0165", + stInOutSensor := "DB_Inputs".Sensors["cInDI0165"]); + // Feedback Hauptschütze aktiv (QA1230/QA1231) + #fbSensorInput(stInSensorHW := "DI0166", + nInSensorNo := "cInDI0166", + stInOutSensor := "DB_Inputs".Sensors["cInDI0166"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0167", + nInSensorNo := "cInBP0167", + stInOutSensor := "DB_Inputs".Sensors["cInBP0167"]); + // Feedback Koppelrelais E-Stop-IF (QA1232/QA1233) + #fbSensorInput(stInSensorHW := "DI0174", + nInSensorNo := "cInDI0174", + stInOutSensor := "DB_Inputs".Sensors["cInDI0174"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0177", + nInSensorNo := "cInSF0177", + stInOutSensor := "DB_Inputs".Sensors["cInSF0177"]); + // Bereichshalt UZ3201 + #fbSensorInput(stInSensorHW := "SF0180", + nInSensorNo := "cInSF0180", + stInOutSensor := "DB_Inputs".Sensors["cInSF0180"]); + // Reset UZ3201 + #fbSensorInput(stInSensorHW := "SF0181", + nInSensorNo := "cInSF0181", + stInOutSensor := "DB_Inputs".Sensors["cInSF0181"]); + // Bereichshalt UZ3202 + #fbSensorInput(stInSensorHW := "SF0182", + nInSensorNo := "cInSF0182", + stInOutSensor := "DB_Inputs".Sensors["cInSF0182"]); + // Reset UZ3202 + #fbSensorInput(stInSensorHW := "SF0183", + nInSensorNo := "cInSF0183", + stInOutSensor := "DB_Inputs".Sensors["cInSF0183"]); + // Bereichshalt UZ3203 + #fbSensorInput(stInSensorHW := "SF0184", + nInSensorNo := "cInSF0184", + stInOutSensor := "DB_Inputs".Sensors["cInSF0184"]); + // Reset UZ3203 + #fbSensorInput(stInSensorHW := "SF0185", + nInSensorNo := "cInSF0185", + stInOutSensor := "DB_Inputs".Sensors["cInSF0185"]); + // Bereichshalt UZ3204 + #fbSensorInput(stInSensorHW := "SF0186", + nInSensorNo := "cInSF0186", + stInOutSensor := "DB_Inputs".Sensors["cInSF0186"]); + // Reset UZ3204 + #fbSensorInput(stInSensorHW := "SF0187", + nInSensorNo := "cInSF0187", + stInOutSensor := "DB_Inputs".Sensors["cInSF0187"]); + // Bereichshalt UZ3205 + #fbSensorInput(stInSensorHW := "SF0190", + nInSensorNo := "cInSF0190", + stInOutSensor := "DB_Inputs".Sensors["cInSF0190"]); + // Reset UZ3205 + #fbSensorInput(stInSensorHW := "SF0191", + nInSensorNo := "cInSF0191", + stInOutSensor := "DB_Inputs".Sensors["cInSF0191"]); + // Bereichshalt UZ3206 + #fbSensorInput(stInSensorHW := "SF0192", + nInSensorNo := "cInSF0192", + stInOutSensor := "DB_Inputs".Sensors["cInSF0192"]); + // Reset UZ3206 + #fbSensorInput(stInSensorHW := "SF0193", + nInSensorNo := "cInSF0193", + stInOutSensor := "DB_Inputs".Sensors["cInSF0193"]); + // Bereichshalt UZ3207 + #fbSensorInput(stInSensorHW := "SF0194", + nInSensorNo := "cInSF0194", + stInOutSensor := "DB_Inputs".Sensors["cInSF0194"]); + // Reset UZ3207 + #fbSensorInput(stInSensorHW := "SF0195", + nInSensorNo := "cInSF0195", + stInOutSensor := "DB_Inputs".Sensors["cInSF0195"]); + // Bereichshalt UZ3208 + #fbSensorInput(stInSensorHW := "SF0196", + nInSensorNo := "cInSF0196", + stInOutSensor := "DB_Inputs".Sensors["cInSF0196"]); + // Reset UZ3208 + #fbSensorInput(stInSensorHW := "SF0197", + nInSensorNo := "cInSF0197", + stInOutSensor := "DB_Inputs".Sensors["cInSF0197"]); + // MSS ausgelöst FC0200 (KR-M2203) + #fbSensorInput(stInSensorHW := "FC0200", + nInSensorNo := "cInFC0200", + stInOutSensor := "DB_Inputs".Sensors["cInFC0200"]); + // MSS ausgelöst FC0201 (KR-M0201) + #fbSensorInput(stInSensorHW := "FC0201", + nInSensorNo := "cInFC0201", + stInOutSensor := "DB_Inputs".Sensors["cInFC0201"]); + // MSS ausgelöst FC0202 (KR-M2301) + #fbSensorInput(stInSensorHW := "FC0202", + nInSensorNo := "cInFC0202", + stInOutSensor := "DB_Inputs".Sensors["cInFC0202"]); + // MSS ausgelöst FC0203 (KR-M2302) + #fbSensorInput(stInSensorHW := "FC0203", + nInSensorNo := "cInFC0203", + stInOutSensor := "DB_Inputs".Sensors["cInFC0203"]); + // MSS ausgelöst FC0204 (CV-M2309) + #fbSensorInput(stInSensorHW := "FC0204", + nInSensorNo := "cInFC0204", + stInOutSensor := "DB_Inputs".Sensors["cInFC0204"]); + // MSS ausgelöst FC0205 (CV-M2209) + #fbSensorInput(stInSensorHW := "FC0205", + nInSensorNo := "cInFC0205", + stInOutSensor := "DB_Inputs".Sensors["cInFC0205"]); + // Meldekontakt 400V Motor+Bremse + #fbSensorInput(stInSensorHW := "DI0220", + nInSensorNo := "cInDI0220", + stInOutSensor := "DB_Inputs".Sensors["cInDI0220"]); + // Vorsicherung 24V OK (FC221) + #fbSensorInput(stInSensorHW := "DI0221", + nInSensorNo := "cInDI0221", + stInOutSensor := "DB_Inputs".Sensors["cInDI0221"]); + // Vorsicherung 24V OK (FC222) + #fbSensorInput(stInSensorHW := "DI0222", + nInSensorNo := "cInDI0222", + stInOutSensor := "DB_Inputs".Sensors["cInDI0222"]); + // Vorsicherung 24V OK (FC223) + #fbSensorInput(stInSensorHW := "DI0223", + nInSensorNo := "cInDI0223", + stInOutSensor := "DB_Inputs".Sensors["cInDI0223"]); + // Feedback Hauptschütze aktiv (QA1540/QA1541) + #fbSensorInput(stInSensorHW := "DI0226", + nInSensorNo := "cInDI0226", + stInOutSensor := "DB_Inputs".Sensors["cInDI0226"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0227", + nInSensorNo := "cInBP0227", + stInOutSensor := "DB_Inputs".Sensors["cInBP0227"]); + // Feedback Koppelrelais E-Stop-IF (QA1542/QA1543) + #fbSensorInput(stInSensorHW := "DI0234", + nInSensorNo := "cInDI0234", + stInOutSensor := "DB_Inputs".Sensors["cInDI0234"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0237", + nInSensorNo := "cInSF0237", + stInOutSensor := "DB_Inputs".Sensors["cInSF0237"]); + // Bereichshalt UZ3301 + #fbSensorInput(stInSensorHW := "SF0240", + nInSensorNo := "cInSF0240", + stInOutSensor := "DB_Inputs".Sensors["cInSF0240"]); + // Reset UZ3301 + #fbSensorInput(stInSensorHW := "SF0241", + nInSensorNo := "cInSF0241", + stInOutSensor := "DB_Inputs".Sensors["cInSF0241"]); + // Bereichshalt UZ3302 + #fbSensorInput(stInSensorHW := "SF0242", + nInSensorNo := "cInSF0242", + stInOutSensor := "DB_Inputs".Sensors["cInSF0242"]); + // Reset UZ3302 + #fbSensorInput(stInSensorHW := "SF0243", + nInSensorNo := "cInSF0243", + stInOutSensor := "DB_Inputs".Sensors["cInSF0243"]); + // Bereichshalt UZ3303 + #fbSensorInput(stInSensorHW := "SF0244", + nInSensorNo := "cInSF0244", + stInOutSensor := "DB_Inputs".Sensors["cInSF0244"]); + // Reset UZ3303 + #fbSensorInput(stInSensorHW := "SF0245", + nInSensorNo := "cInSF0245", + stInOutSensor := "DB_Inputs".Sensors["cInSF0245"]); + // Bereichshalt UZ3304 + #fbSensorInput(stInSensorHW := "SF0246", + nInSensorNo := "cInSF0246", + stInOutSensor := "DB_Inputs".Sensors["cInSF0246"]); + // Reset UZ3304 + #fbSensorInput(stInSensorHW := "SF0247", + nInSensorNo := "cInSF0247", + stInOutSensor := "DB_Inputs".Sensors["cInSF0247"]); + // MSS ausgelöst FC0260 (KR-M2303) + #fbSensorInput(stInSensorHW := "FC0260", + nInSensorNo := "cInFC0260", + stInOutSensor := "DB_Inputs".Sensors["cInFC0260"]); + // MSS ausgelöst FC0261 (KR-M2304) + #fbSensorInput(stInSensorHW := "FC0261", + nInSensorNo := "cInFC0261", + stInOutSensor := "DB_Inputs".Sensors["cInFC0261"]); + // MSS ausgelöst FC0262 (CV-M2305) + #fbSensorInput(stInSensorHW := "FC0262", + nInSensorNo := "cInFC0262", + stInOutSensor := "DB_Inputs".Sensors["cInFC0262"]); + // MSS ausgelöst FC0263 (CV-M2306) + #fbSensorInput(stInSensorHW := "FC0263", + nInSensorNo := "cInFC0263", + stInOutSensor := "DB_Inputs".Sensors["cInFC0263"]); + // MSS ausgelöst FC0264 (CV-M2307) + #fbSensorInput(stInSensorHW := "FC0264", + nInSensorNo := "cInFC0264", + stInOutSensor := "DB_Inputs".Sensors["cInFC0264"]); + // MSS ausgelöst FC0265 (CV-M2308) + #fbSensorInput(stInSensorHW := "FC0265", + nInSensorNo := "cInFC0265", + stInOutSensor := "DB_Inputs".Sensors["cInFC0265"]); + // Not Halt Kanal 1 UH03 + #fbSensorInput(stInSensorHW := "SF0400", + nInSensorNo := "cInSF0400", + stInOutSensor := "DB_Inputs".Sensors["cInSF0400"]); + // Not Halt Kanal 1 UZ0301 + #fbSensorInput(stInSensorHW := "SF0401", + nInSensorNo := "cInSF0401", + stInOutSensor := "DB_Inputs".Sensors["cInSF0401"]); + // Not Halt Kanal 1 UZ0302 + #fbSensorInput(stInSensorHW := "SF0402", + nInSensorNo := "cInSF0402", + stInOutSensor := "DB_Inputs".Sensors["cInSF0402"]); + // Not Halt Kanal 1 UZ0303 + #fbSensorInput(stInSensorHW := "SF0403", + nInSensorNo := "cInSF0403", + stInOutSensor := "DB_Inputs".Sensors["cInSF0403"]); + // Not Halt Kanal 2 UH03 + #fbSensorInput(stInSensorHW := "SF0404", + nInSensorNo := "cInSF0404", + stInOutSensor := "DB_Inputs".Sensors["cInSF0404"]); + // Not Halt Kanal 2 UZ0301 + #fbSensorInput(stInSensorHW := "SF0405", + nInSensorNo := "cInSF0405", + stInOutSensor := "DB_Inputs".Sensors["cInSF0405"]); + // Not Halt Kanal 2 UZ0302 + #fbSensorInput(stInSensorHW := "SF0406", + nInSensorNo := "cInSF0406", + stInOutSensor := "DB_Inputs".Sensors["cInSF0406"]); + // Not Halt Kanal 2 UZ0303 + #fbSensorInput(stInSensorHW := "SF0407", + nInSensorNo := "cInSF0407", + stInOutSensor := "DB_Inputs".Sensors["cInSF0407"]); + // Not Halt Kanal 1 UZ0304 + #fbSensorInput(stInSensorHW := "SF0470", + nInSensorNo := "cInSF0470", + stInOutSensor := "DB_Inputs".Sensors["cInSF0470"]); + // Not Halt Kanal 1 UZ0309 + #fbSensorInput(stInSensorHW := "SF0471", + nInSensorNo := "cInSF0471", + stInOutSensor := "DB_Inputs".Sensors["cInSF0471"]); + // Not Halt Kanal 1 UZ0310 + #fbSensorInput(stInSensorHW := "SF0472", + nInSensorNo := "cInSF0472", + stInOutSensor := "DB_Inputs".Sensors["cInSF0472"]); + // Not Halt Kanal 2 UZ0304 + #fbSensorInput(stInSensorHW := "SF0474", + nInSensorNo := "cInSF0474", + stInOutSensor := "DB_Inputs".Sensors["cInSF0474"]); + // Not Halt Kanal 2 UZ0309 + #fbSensorInput(stInSensorHW := "SF0475", + nInSensorNo := "cInSF0475", + stInOutSensor := "DB_Inputs".Sensors["cInSF0475"]); + // Not Halt Kanal 2 UZ0310 + #fbSensorInput(stInSensorHW := "SF0476", + nInSensorNo := "cInSF0476", + stInOutSensor := "DB_Inputs".Sensors["cInSF0476"]); + // Not Halt Schnittstelle CH1 (UC072) + #fbSensorInput(stInSensorHW := "SF0541", + nInSensorNo := "cInSF0541", + stInOutSensor := "DB_Inputs".Sensors["cInSF0541"]); + // Not Halt Schnittstelle CH2 (von UH02) + #fbSensorInput(stInSensorHW := "SF0542", + nInSensorNo := "cInSF0542", + stInOutSensor := "DB_Inputs".Sensors["cInSF0542"]); + // Not Halt Schnittstelle CH1 (UC072) + #fbSensorInput(stInSensorHW := "SF0545", + nInSensorNo := "cInSF0545", + stInOutSensor := "DB_Inputs".Sensors["cInSF0545"]); + // Not Halt Schnittstelle CH2 (zu UH02) + #fbSensorInput(stInSensorHW := "SF0546", + nInSensorNo := "cInSF0546", + stInOutSensor := "DB_Inputs".Sensors["cInSF0546"]); + // Not Halt Kanal 1 UC031 + #fbSensorInput(stInSensorHW := "SF0710", + nInSensorNo := "cInSF0710", + stInOutSensor := "DB_Inputs".Sensors["cInSF0710"]); + // Not Halt Kanal 1 UZ3101 + #fbSensorInput(stInSensorHW := "SF0711", + nInSensorNo := "cInSF0711", + stInOutSensor := "DB_Inputs".Sensors["cInSF0711"]); + // Not Halt Kanal 1 UZ3102 + #fbSensorInput(stInSensorHW := "SF0712", + nInSensorNo := "cInSF0712", + stInOutSensor := "DB_Inputs".Sensors["cInSF0712"]); + // Not Halt Kanal 1 UZ3103 + #fbSensorInput(stInSensorHW := "SF0713", + nInSensorNo := "cInSF0713", + stInOutSensor := "DB_Inputs".Sensors["cInSF0713"]); + // Not Halt Kanal 2 UC031 + #fbSensorInput(stInSensorHW := "SF0714", + nInSensorNo := "cInSF0714", + stInOutSensor := "DB_Inputs".Sensors["cInSF0714"]); + // Not Halt Kanal 2 UZ3101 + #fbSensorInput(stInSensorHW := "SF0715", + nInSensorNo := "cInSF0715", + stInOutSensor := "DB_Inputs".Sensors["cInSF0715"]); + // Not Halt Kanal 2 UZ3102 + #fbSensorInput(stInSensorHW := "SF0716", + nInSensorNo := "cInSF0716", + stInOutSensor := "DB_Inputs".Sensors["cInSF0716"]); + // Not Halt Kanal 2 UZ3103 + #fbSensorInput(stInSensorHW := "SF0717", + nInSensorNo := "cInSF0717", + stInOutSensor := "DB_Inputs".Sensors["cInSF0717"]); + // Not Halt Kanal 1 UZ3104 + #fbSensorInput(stInSensorHW := "SF0780", + nInSensorNo := "cInSF0780", + stInOutSensor := "DB_Inputs".Sensors["cInSF0780"]); + // Not Halt Schnittstelle CH1 + #fbSensorInput(stInSensorHW := "SF0781", + nInSensorNo := "cInSF0781", + stInOutSensor := "DB_Inputs".Sensors["cInSF0781"]); + // Not Halt Kanal 2 UZ3104 + #fbSensorInput(stInSensorHW := "SF0784", + nInSensorNo := "cInSF0784", + stInOutSensor := "DB_Inputs".Sensors["cInSF0784"]); + // Not Halt Schnittstelle CH2 + #fbSensorInput(stInSensorHW := "SF0785", + nInSensorNo := "cInSF0785", + stInOutSensor := "DB_Inputs".Sensors["cInSF0785"]); + // Not Halt Kanal 1 UC032 + #fbSensorInput(stInSensorHW := "SF1020", + nInSensorNo := "cInSF1020", + stInOutSensor := "DB_Inputs".Sensors["cInSF1020"]); + // Not Halt Kanal 1 UZ3201 + #fbSensorInput(stInSensorHW := "SF1021", + nInSensorNo := "cInSF1021", + stInOutSensor := "DB_Inputs".Sensors["cInSF1021"]); + // Not Halt Kanal 1 UZ3202 + #fbSensorInput(stInSensorHW := "SF1022", + nInSensorNo := "cInSF1022", + stInOutSensor := "DB_Inputs".Sensors["cInSF1022"]); + // Not Halt Kanal 1 UZ3203 + #fbSensorInput(stInSensorHW := "SF1023", + nInSensorNo := "cInSF1023", + stInOutSensor := "DB_Inputs".Sensors["cInSF1023"]); + // Not Halt Kanal 2 UC032 + #fbSensorInput(stInSensorHW := "SF1024", + nInSensorNo := "cInSF1024", + stInOutSensor := "DB_Inputs".Sensors["cInSF1024"]); + // Not Halt Kanal 2 UZ3201 + #fbSensorInput(stInSensorHW := "SF1025", + nInSensorNo := "cInSF1025", + stInOutSensor := "DB_Inputs".Sensors["cInSF1025"]); + // Not Halt Kanal 2 UZ3202 + #fbSensorInput(stInSensorHW := "SF1026", + nInSensorNo := "cInSF1026", + stInOutSensor := "DB_Inputs".Sensors["cInSF1026"]); + // Not Halt Kanal 2 UZ3203 + #fbSensorInput(stInSensorHW := "SF1027", + nInSensorNo := "cInSF1027", + stInOutSensor := "DB_Inputs".Sensors["cInSF1027"]); + // Not Halt Kanal 1 UZ3204 + #fbSensorInput(stInSensorHW := "SF1090", + nInSensorNo := "cInSF1090", + stInOutSensor := "DB_Inputs".Sensors["cInSF1090"]); + // Not Halt Schnittstelle CH1 + #fbSensorInput(stInSensorHW := "SF1091", + nInSensorNo := "cInSF1091", + stInOutSensor := "DB_Inputs".Sensors["cInSF1091"]); + // Not Halt Kanal 2 UZ3204 + #fbSensorInput(stInSensorHW := "SF1094", + nInSensorNo := "cInSF1094", + stInOutSensor := "DB_Inputs".Sensors["cInSF1094"]); + // Not Halt Schnittstelle CH2 + #fbSensorInput(stInSensorHW := "SF1095", + nInSensorNo := "cInSF1095", + stInOutSensor := "DB_Inputs".Sensors["cInSF1095"]); + // Not Halt Kanal 1 UC033 + #fbSensorInput(stInSensorHW := "SF1330", + nInSensorNo := "cInSF1330", + stInOutSensor := "DB_Inputs".Sensors["cInSF1330"]); + // Not Halt Kanal 1 UZ3301 + #fbSensorInput(stInSensorHW := "SF1331", + nInSensorNo := "cInSF1331", + stInOutSensor := "DB_Inputs".Sensors["cInSF1331"]); + // Not Halt Kanal 1 UZ3302 + #fbSensorInput(stInSensorHW := "SF1332", + nInSensorNo := "cInSF1332", + stInOutSensor := "DB_Inputs".Sensors["cInSF1332"]); + // Not Halt Kanal 1 UZ3303 + #fbSensorInput(stInSensorHW := "SF1333", + nInSensorNo := "cInSF1333", + stInOutSensor := "DB_Inputs".Sensors["cInSF1333"]); + // Not Halt Kanal 2 UC033 + #fbSensorInput(stInSensorHW := "SF1334", + nInSensorNo := "cInSF1334", + stInOutSensor := "DB_Inputs".Sensors["cInSF1334"]); + // Not Halt Kanal 2 UZ3301 + #fbSensorInput(stInSensorHW := "SF1335", + nInSensorNo := "cInSF1335", + stInOutSensor := "DB_Inputs".Sensors["cInSF1335"]); + // Not Halt Kanal 2 UZ3302 + #fbSensorInput(stInSensorHW := "SF1336", + nInSensorNo := "cInSF1336", + stInOutSensor := "DB_Inputs".Sensors["cInSF1336"]); + // Not Halt Kanal 2 UZ3303 + #fbSensorInput(stInSensorHW := "SF1337", + nInSensorNo := "cInSF1337", + stInOutSensor := "DB_Inputs".Sensors["cInSF1337"]); + // Not Halt Kanal 1 UZ3304 + #fbSensorInput(stInSensorHW := "SF1400", + nInSensorNo := "cInSF1400", + stInOutSensor := "DB_Inputs".Sensors["cInSF1400"]); + // Not Halt Schnittstelle CH1 + #fbSensorInput(stInSensorHW := "SF1401", + nInSensorNo := "cInSF1401", + stInOutSensor := "DB_Inputs".Sensors["cInSF1401"]); + // Not Halt Kanal 2 UZ3304 + #fbSensorInput(stInSensorHW := "SF1404", + nInSensorNo := "cInSF1404", + stInOutSensor := "DB_Inputs".Sensors["cInSF1404"]); + // Not Halt Schnittstelle CH2 + #fbSensorInput(stInSensorHW := "SF1405", + nInSensorNo := "cInSF1405", + stInOutSensor := "DB_Inputs".Sensors["cInSF1405"]); + // Not Halt Kanal 1 UZ0305 + #fbSensorInput(stInSensorHW := "SF1470", + nInSensorNo := "cInSF1470", + stInOutSensor := "DB_Inputs".Sensors["cInSF1470"]); + // Not Halt Kanal 1 UZ0306 + #fbSensorInput(stInSensorHW := "SF1471", + nInSensorNo := "cInSF1471", + stInOutSensor := "DB_Inputs".Sensors["cInSF1471"]); + // Not Halt Kanal 1 UZ0307 + #fbSensorInput(stInSensorHW := "SF1472", + nInSensorNo := "cInSF1472", + stInOutSensor := "DB_Inputs".Sensors["cInSF1472"]); + // Not Halt Kanal 1 UZ0308 + #fbSensorInput(stInSensorHW := "SF1473", + nInSensorNo := "cInSF1473", + stInOutSensor := "DB_Inputs".Sensors["cInSF1473"]); + // Not Halt Kanal 2 UZ0305 + #fbSensorInput(stInSensorHW := "SF1474", + nInSensorNo := "cInSF1474", + stInOutSensor := "DB_Inputs".Sensors["cInSF1474"]); + // Not Halt Kanal 2 UZ0306 + #fbSensorInput(stInSensorHW := "SF1475", + nInSensorNo := "cInSF1475", + stInOutSensor := "DB_Inputs".Sensors["cInSF1475"]); + // Not Halt Kanal 2 UZ0307 + #fbSensorInput(stInSensorHW := "SF1476", + nInSensorNo := "cInSF1476", + stInOutSensor := "DB_Inputs".Sensors["cInSF1476"]); + // Not Halt Kanal 2 UZ0308 + #fbSensorInput(stInSensorHW := "SF1477", + nInSensorNo := "cInSF1477", + stInOutSensor := "DB_Inputs".Sensors["cInSF1477"]); + // in Separator 2 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3000", + nInSensorNo := "cInBG3000", + stInOutSensor := "DB_Inputs".Sensors["cInBG3000"]); + // Pin Abfrage (KR-M2101 ) Block 2.1.1 + #fbSensorInput(stInSensorHW := "BG3001", + nInSensorNo := "cInBG3001", + stInOutSensor := "DB_Inputs".Sensors["cInBG3001"]); + // Prüfung MT Pos.1 (KR-K2101 Einfahrt Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3002", + nInSensorNo := "cInBG3002", + stInOutSensor := "DB_Inputs".Sensors["cInBG3002"]); + // Stausensor (KR-M2101) + #fbSensorInput(stInSensorHW := "BG3003", + nInSensorNo := "cInBG3003", + stInOutSensor := "DB_Inputs".Sensors["cInBG3003"]); + // in Separator 1 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3004", + nInSensorNo := "cInBG3004", + stInOutSensor := "DB_Inputs".Sensors["cInBG3004"]); + // Stausensor Str.1 (KR-K2105 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3005", + nInSensorNo := "cInBG3005", + stInOutSensor := "DB_Inputs".Sensors["cInBG3005"]); + // Sensor Förderer voll (ILS-CV 2105) + #fbSensorInput(stInSensorHW := "BG3006", + nInSensorNo := "cInBG3006", + stInOutSensor := "DB_Inputs".Sensors["cInBG3006"]); + // Prüfung MT Pos.2 (KR-K2101 Einfahrt Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3007", + nInSensorNo := "cInBG3007", + stInOutSensor := "DB_Inputs".Sensors["cInBG3007"]); + // Prüfung MT Pos.3 (KR-K2101 Einfahrt Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3010", + nInSensorNo := "cInBG3010", + stInOutSensor := "DB_Inputs".Sensors["cInBG3010"]); + // Prüfung MT Pos.4 (KR-K2101 Einfahrt Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3011", + nInSensorNo := "cInBG3011", + stInOutSensor := "DB_Inputs".Sensors["cInBG3011"]); + // Prüfung MT Pos.5 (KR-K2101 Einfahrt Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3012", + nInSensorNo := "cInBG3012", + stInOutSensor := "DB_Inputs".Sensors["cInBG3012"]); + // Stausensor Str.1 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3030", + nInSensorNo := "cInBG3030", + stInOutSensor := "DB_Inputs".Sensors["cInBG3030"]); + // Stausensor Str.2 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3031", + nInSensorNo := "cInBG3031", + stInOutSensor := "DB_Inputs".Sensors["cInBG3031"]); + // Stausensor Str.3 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3032", + nInSensorNo := "cInBG3032", + stInOutSensor := "DB_Inputs".Sensors["cInBG3032"]); + // Stausensor Str.4 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3033", + nInSensorNo := "cInBG3033", + stInOutSensor := "DB_Inputs".Sensors["cInBG3033"]); + // Stausensor Str.5 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3034", + nInSensorNo := "cInBG3034", + stInOutSensor := "DB_Inputs".Sensors["cInBG3034"]); + // Stausensor Str.6 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3035", + nInSensorNo := "cInBG3035", + stInOutSensor := "DB_Inputs".Sensors["cInBG3035"]); + // Stausensor Str.7 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3036", + nInSensorNo := "cInBG3036", + stInOutSensor := "DB_Inputs".Sensors["cInBG3036"]); + // Stausensor Str.8 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3037", + nInSensorNo := "cInBG3037", + stInOutSensor := "DB_Inputs".Sensors["cInBG3037"]); + // Stausensor Str.9 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3040", + nInSensorNo := "cInBG3040", + stInOutSensor := "DB_Inputs".Sensors["cInBG3040"]); + // Stausensor Str.10 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3041", + nInSensorNo := "cInBG3041", + stInOutSensor := "DB_Inputs".Sensors["cInBG3041"]); + // Stausensor Str.11 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3042", + nInSensorNo := "cInBG3042", + stInOutSensor := "DB_Inputs".Sensors["cInBG3042"]); + // Stausensor Str.12 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3043", + nInSensorNo := "cInBG3043", + stInOutSensor := "DB_Inputs".Sensors["cInBG3043"]); + // Stausensor Str.13 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3044", + nInSensorNo := "cInBG3044", + stInOutSensor := "DB_Inputs".Sensors["cInBG3044"]); + // Stausensor Str.14 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3045", + nInSensorNo := "cInBG3045", + stInOutSensor := "DB_Inputs".Sensors["cInBG3045"]); + // Stausensor Str.15 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3046", + nInSensorNo := "cInBG3046", + stInOutSensor := "DB_Inputs".Sensors["cInBG3046"]); + // Stausensor Str.16 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3047", + nInSensorNo := "cInBG3047", + stInOutSensor := "DB_Inputs".Sensors["cInBG3047"]); + // Stausensor Str.17 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3050", + nInSensorNo := "cInBG3050", + stInOutSensor := "DB_Inputs".Sensors["cInBG3050"]); + // Stausensor Str.18 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3051", + nInSensorNo := "cInBG3051", + stInOutSensor := "DB_Inputs".Sensors["cInBG3051"]); + // Stausensor Str.19 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3052", + nInSensorNo := "cInBG3052", + stInOutSensor := "DB_Inputs".Sensors["cInBG3052"]); + // in Separator 2 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3060", + nInSensorNo := "cInBG3060", + stInOutSensor := "DB_Inputs".Sensors["cInBG3060"]); + // Pin Abfrage (KR-M2101 ) Block 2.1.2 + #fbSensorInput(stInSensorHW := "BG3061", + nInSensorNo := "cInBG3061", + stInOutSensor := "DB_Inputs".Sensors["cInBG3061"]); + // Prüfung MT Pos.1 (KR-K2101 Einfahrt Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3062", + nInSensorNo := "cInBG3062", + stInOutSensor := "DB_Inputs".Sensors["cInBG3062"]); + // Stausensor Str.2 (KR-M2101) + #fbSensorInput(stInSensorHW := "BG3063", + nInSensorNo := "cInBG3063", + stInOutSensor := "DB_Inputs".Sensors["cInBG3063"]); + // in Separator 1 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3064", + nInSensorNo := "cInBG3064", + stInOutSensor := "DB_Inputs".Sensors["cInBG3064"]); + // Stausensor Str.1 (KR-K2101 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3065", + nInSensorNo := "cInBG3065", + stInOutSensor := "DB_Inputs".Sensors["cInBG3065"]); + // Sensor Förderer voll (ILS-CV 2106) + #fbSensorInput(stInSensorHW := "BG3066", + nInSensorNo := "cInBG3066", + stInOutSensor := "DB_Inputs".Sensors["cInBG3066"]); + // Prüfung MT Pos.2 (KR-K2101 Einfahrt Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3067", + nInSensorNo := "cInBG3067", + stInOutSensor := "DB_Inputs".Sensors["cInBG3067"]); + // Prüfung MT Pos.3 (KR-K2101 Einfahrt Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3070", + nInSensorNo := "cInBG3070", + stInOutSensor := "DB_Inputs".Sensors["cInBG3070"]); + // Prüfung MT Pos.4 (KR-K2101 Einfahrt Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3071", + nInSensorNo := "cInBG3071", + stInOutSensor := "DB_Inputs".Sensors["cInBG3071"]); + // Prüfung MT Pos.5 (KR-K2101 Einfahrt Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3072", + nInSensorNo := "cInBG3072", + stInOutSensor := "DB_Inputs".Sensors["cInBG3072"]); + // Stausensor MT vor Pinband (KR-M2101 Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3073", + nInSensorNo := "cInBG3073", + stInOutSensor := "DB_Inputs".Sensors["cInBG3073"]); + // Stausensor Str.1 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3090", + nInSensorNo := "cInBG3090", + stInOutSensor := "DB_Inputs".Sensors["cInBG3090"]); + // Stausensor Str.2 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3091", + nInSensorNo := "cInBG3091", + stInOutSensor := "DB_Inputs".Sensors["cInBG3091"]); + // Stausensor Str.3 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3092", + nInSensorNo := "cInBG3092", + stInOutSensor := "DB_Inputs".Sensors["cInBG3092"]); + // Stausensor Str.4 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3093", + nInSensorNo := "cInBG3093", + stInOutSensor := "DB_Inputs".Sensors["cInBG3093"]); + // Stausensor Str.5 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3094", + nInSensorNo := "cInBG3094", + stInOutSensor := "DB_Inputs".Sensors["cInBG3094"]); + // Stausensor Str.6 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3095", + nInSensorNo := "cInBG3095", + stInOutSensor := "DB_Inputs".Sensors["cInBG3095"]); + // Stausensor Str.7 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3096", + nInSensorNo := "cInBG3096", + stInOutSensor := "DB_Inputs".Sensors["cInBG3096"]); + // Stausensor Str.8 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3097", + nInSensorNo := "cInBG3097", + stInOutSensor := "DB_Inputs".Sensors["cInBG3097"]); + // Stausensor Str.9 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3100", + nInSensorNo := "cInBG3100", + stInOutSensor := "DB_Inputs".Sensors["cInBG3100"]); + // Stausensor Str.10 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3101", + nInSensorNo := "cInBG3101", + stInOutSensor := "DB_Inputs".Sensors["cInBG3101"]); + // Stausensor Str.11 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3102", + nInSensorNo := "cInBG3102", + stInOutSensor := "DB_Inputs".Sensors["cInBG3102"]); + // Stausensor Str.12 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3103", + nInSensorNo := "cInBG3103", + stInOutSensor := "DB_Inputs".Sensors["cInBG3103"]); + // Stausensor Str.13 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3104", + nInSensorNo := "cInBG3104", + stInOutSensor := "DB_Inputs".Sensors["cInBG3104"]); + // Stausensor Str.14 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3105", + nInSensorNo := "cInBG3105", + stInOutSensor := "DB_Inputs".Sensors["cInBG3105"]); + // Stausensor Str.15 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3106", + nInSensorNo := "cInBG3106", + stInOutSensor := "DB_Inputs".Sensors["cInBG3106"]); + // Stausensor Str.16 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3107", + nInSensorNo := "cInBG3107", + stInOutSensor := "DB_Inputs".Sensors["cInBG3107"]); + // Stausensor Str.17 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3110", + nInSensorNo := "cInBG3110", + stInOutSensor := "DB_Inputs".Sensors["cInBG3110"]); + // in Separator 2 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3120", + nInSensorNo := "cInBG3120", + stInOutSensor := "DB_Inputs".Sensors["cInBG3120"]); + // Pin Abfrage (KR-M2102 ) Block 2.1.3 + #fbSensorInput(stInSensorHW := "BG3121", + nInSensorNo := "cInBG3121", + stInOutSensor := "DB_Inputs".Sensors["cInBG3121"]); + // Prüfung MT Pos.1 (KR-K2102 Einfahrt Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3122", + nInSensorNo := "cInBG3122", + stInOutSensor := "DB_Inputs".Sensors["cInBG3122"]); + // Stausensor Str.2 (KR-M2102) + #fbSensorInput(stInSensorHW := "BG3123", + nInSensorNo := "cInBG3123", + stInOutSensor := "DB_Inputs".Sensors["cInBG3123"]); + // in Separator 1 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3124", + nInSensorNo := "cInBG3124", + stInOutSensor := "DB_Inputs".Sensors["cInBG3124"]); + // Stausensor Str.1 (KR-K2107 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3125", + nInSensorNo := "cInBG3125", + stInOutSensor := "DB_Inputs".Sensors["cInBG3125"]); + // Sensor Förderer voll (ILS-CV 2107) + #fbSensorInput(stInSensorHW := "BG3126", + nInSensorNo := "cInBG3126", + stInOutSensor := "DB_Inputs".Sensors["cInBG3126"]); + // Prüfung MT Pos.2 (KR-K2102 Einfahrt Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3127", + nInSensorNo := "cInBG3127", + stInOutSensor := "DB_Inputs".Sensors["cInBG3127"]); + // Prüfung MT Pos.3 (KR-K2102 Einfahrt Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3130", + nInSensorNo := "cInBG3130", + stInOutSensor := "DB_Inputs".Sensors["cInBG3130"]); + // Prüfung MT Pos.4 (KR-K2102 Einfahrt Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3131", + nInSensorNo := "cInBG3131", + stInOutSensor := "DB_Inputs".Sensors["cInBG3131"]); + // Prüfung MT Pos.5 (KR-K2102 Einfahrt Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3132", + nInSensorNo := "cInBG3132", + stInOutSensor := "DB_Inputs".Sensors["cInBG3132"]); + // Prüfung MT Pos.6 (KR-K2102 Einfahrt Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3133", + nInSensorNo := "cInBG3133", + stInOutSensor := "DB_Inputs".Sensors["cInBG3133"]); + // in Separator 3 (KR-M2102 Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3134", + nInSensorNo := "cInBG3134", + stInOutSensor := "DB_Inputs".Sensors["cInBG3134"]); + // Stausensor (ILS-CV 1 M1109) + #fbSensorInput(stInSensorHW := "BG3135", + nInSensorNo := "cInBG3135", + stInOutSensor := "DB_Inputs".Sensors["cInBG3135"]); + // Stausensor 1 (KR-M2102) + #fbSensorInput(stInSensorHW := "BG3136", + nInSensorNo := "cInBG3136", + stInOutSensor := "DB_Inputs".Sensors["cInBG3136"]); + // in Separator 4 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3137", + nInSensorNo := "cInBG3137", + stInOutSensor := "DB_Inputs".Sensors["cInBG3137"]); + // Stausensor MT vor Pinband (KR-M2102 Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3140", + nInSensorNo := "cInBG3140", + stInOutSensor := "DB_Inputs".Sensors["cInBG3140"]); + // Stausensor Str.1 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3150", + nInSensorNo := "cInBG3150", + stInOutSensor := "DB_Inputs".Sensors["cInBG3150"]); + // Stausensor Str.2 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3151", + nInSensorNo := "cInBG3151", + stInOutSensor := "DB_Inputs".Sensors["cInBG3151"]); + // Stausensor Str.3 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3152", + nInSensorNo := "cInBG3152", + stInOutSensor := "DB_Inputs".Sensors["cInBG3152"]); + // Stausensor Str.4 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3153", + nInSensorNo := "cInBG3153", + stInOutSensor := "DB_Inputs".Sensors["cInBG3153"]); + // Stausensor Str.5 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3154", + nInSensorNo := "cInBG3154", + stInOutSensor := "DB_Inputs".Sensors["cInBG3154"]); + // Stausensor Str.6 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3155", + nInSensorNo := "cInBG3155", + stInOutSensor := "DB_Inputs".Sensors["cInBG3155"]); + // Stausensor Str.7 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3156", + nInSensorNo := "cInBG3156", + stInOutSensor := "DB_Inputs".Sensors["cInBG3156"]); + // Stausensor Str.8 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3157", + nInSensorNo := "cInBG3157", + stInOutSensor := "DB_Inputs".Sensors["cInBG3157"]); + // Stausensor Str.9 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3160", + nInSensorNo := "cInBG3160", + stInOutSensor := "DB_Inputs".Sensors["cInBG3160"]); + // Stausensor Str.10 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3161", + nInSensorNo := "cInBG3161", + stInOutSensor := "DB_Inputs".Sensors["cInBG3161"]); + // Stausensor Str.11 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3162", + nInSensorNo := "cInBG3162", + stInOutSensor := "DB_Inputs".Sensors["cInBG3162"]); + // Stausensor Str.12 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3163", + nInSensorNo := "cInBG3163", + stInOutSensor := "DB_Inputs".Sensors["cInBG3163"]); + // Stausensor Str.13 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3164", + nInSensorNo := "cInBG3164", + stInOutSensor := "DB_Inputs".Sensors["cInBG3164"]); + // Stausensor Str.14 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3165", + nInSensorNo := "cInBG3165", + stInOutSensor := "DB_Inputs".Sensors["cInBG3165"]); + // Stausensor Str.15 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3166", + nInSensorNo := "cInBG3166", + stInOutSensor := "DB_Inputs".Sensors["cInBG3166"]); + // Stausensor Str.16 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3167", + nInSensorNo := "cInBG3167", + stInOutSensor := "DB_Inputs".Sensors["cInBG3167"]); + // Stausensor Str.17 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3170", + nInSensorNo := "cInBG3170", + stInOutSensor := "DB_Inputs".Sensors["cInBG3170"]); + // Stausensor Str.18 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3171", + nInSensorNo := "cInBG3171", + stInOutSensor := "DB_Inputs".Sensors["cInBG3171"]); + // Stausensor Str.19 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3172", + nInSensorNo := "cInBG3172", + stInOutSensor := "DB_Inputs".Sensors["cInBG3172"]); + // Stausensor Str.20 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3173", + nInSensorNo := "cInBG3173", + stInOutSensor := "DB_Inputs".Sensors["cInBG3173"]); + // Stausensor Str.21 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3174", + nInSensorNo := "cInBG3174", + stInOutSensor := "DB_Inputs".Sensors["cInBG3174"]); + // in Separator 2 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3180", + nInSensorNo := "cInBG3180", + stInOutSensor := "DB_Inputs".Sensors["cInBG3180"]); + // Pin Abfrage (KR-M2102 ) Block 2.1.4 + #fbSensorInput(stInSensorHW := "BG3181", + nInSensorNo := "cInBG3181", + stInOutSensor := "DB_Inputs".Sensors["cInBG3181"]); + // Prüfung MT Pos.1 (KR-K2102 Einfahrt Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3182", + nInSensorNo := "cInBG3182", + stInOutSensor := "DB_Inputs".Sensors["cInBG3182"]); + // Stausensor (KR-M2102 Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3183", + nInSensorNo := "cInBG3183", + stInOutSensor := "DB_Inputs".Sensors["cInBG3183"]); + // in Separator 1 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3184", + nInSensorNo := "cInBG3184", + stInOutSensor := "DB_Inputs".Sensors["cInBG3184"]); + // Stausensor Str.1 (KR-K2102 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3185", + nInSensorNo := "cInBG3185", + stInOutSensor := "DB_Inputs".Sensors["cInBG3185"]); + // Sensor Förderer voll (ILS-CV 2102) + #fbSensorInput(stInSensorHW := "BG3186", + nInSensorNo := "cInBG3186", + stInOutSensor := "DB_Inputs".Sensors["cInBG3186"]); + // Prüfung MT Pos.2 (KR-K2102 Einfahrt Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3187", + nInSensorNo := "cInBG3187", + stInOutSensor := "DB_Inputs".Sensors["cInBG3187"]); + // Prüfung MT Pos.3 (KR-K2102 Einfahrt Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3190", + nInSensorNo := "cInBG3190", + stInOutSensor := "DB_Inputs".Sensors["cInBG3190"]); + // Prüfung MT Pos.4 (KR-K2102 Einfahrt Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3191", + nInSensorNo := "cInBG3191", + stInOutSensor := "DB_Inputs".Sensors["cInBG3191"]); + // in Separator 3 (KR-M2102 Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3192", + nInSensorNo := "cInBG3192", + stInOutSensor := "DB_Inputs".Sensors["cInBG3192"]); + // Stausensor (KR-M2102 Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3193", + nInSensorNo := "cInBG3193", + stInOutSensor := "DB_Inputs".Sensors["cInBG3193"]); + // Stausensor (KR-M2102 Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3194", + nInSensorNo := "cInBG3194", + stInOutSensor := "DB_Inputs".Sensors["cInBG3194"]); + // Stausensor Str.1 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3210", + nInSensorNo := "cInBG3210", + stInOutSensor := "DB_Inputs".Sensors["cInBG3210"]); + // Stausensor Str.2 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3211", + nInSensorNo := "cInBG3211", + stInOutSensor := "DB_Inputs".Sensors["cInBG3211"]); + // Stausensor Str.3 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3212", + nInSensorNo := "cInBG3212", + stInOutSensor := "DB_Inputs".Sensors["cInBG3212"]); + // Stausensor Str.4 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3213", + nInSensorNo := "cInBG3213", + stInOutSensor := "DB_Inputs".Sensors["cInBG3213"]); + // Stausensor Str.5 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3214", + nInSensorNo := "cInBG3214", + stInOutSensor := "DB_Inputs".Sensors["cInBG3214"]); + // Stausensor Str.6 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3215", + nInSensorNo := "cInBG3215", + stInOutSensor := "DB_Inputs".Sensors["cInBG3215"]); + // Stausensor Str.7 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3216", + nInSensorNo := "cInBG3216", + stInOutSensor := "DB_Inputs".Sensors["cInBG3216"]); + // Stausensor Str.8 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3217", + nInSensorNo := "cInBG3217", + stInOutSensor := "DB_Inputs".Sensors["cInBG3217"]); + // Stausensor Str.9 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3220", + nInSensorNo := "cInBG3220", + stInOutSensor := "DB_Inputs".Sensors["cInBG3220"]); + // Stausensor Str.10 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3221", + nInSensorNo := "cInBG3221", + stInOutSensor := "DB_Inputs".Sensors["cInBG3221"]); + // Stausensor Str.11 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3222", + nInSensorNo := "cInBG3222", + stInOutSensor := "DB_Inputs".Sensors["cInBG3222"]); + // Stausensor Str.12 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3223", + nInSensorNo := "cInBG3223", + stInOutSensor := "DB_Inputs".Sensors["cInBG3223"]); + // Stausensor Str.13 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3224", + nInSensorNo := "cInBG3224", + stInOutSensor := "DB_Inputs".Sensors["cInBG3224"]); + // in Separator 1 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3240", + nInSensorNo := "cInBG3240", + stInOutSensor := "DB_Inputs".Sensors["cInBG3240"]); + // Staumelder, Einfahrt (ILS-CV M2105) + #fbSensorInput(stInSensorHW := "BG3241", + nInSensorNo := "cInBG3241", + stInOutSensor := "DB_Inputs".Sensors["cInBG3241"]); + // Stausensor 1 (KR-M2103 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3242", + nInSensorNo := "cInBG3242", + stInOutSensor := "DB_Inputs".Sensors["cInBG3242"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2105) + #fbSensorInput(stInSensorHW := "BG3243", + nInSensorNo := "cInBG3243", + stInOutSensor := "DB_Inputs".Sensors["cInBG3243"]); + // in Separator (ILS-CV M2105) + #fbSensorInput(stInSensorHW := "BG3244", + nInSensorNo := "cInBG3244", + stInOutSensor := "DB_Inputs".Sensors["cInBG3244"]); + // in Separator (KR-M2103) + #fbSensorInput(stInSensorHW := "BG3245", + nInSensorNo := "cInBG3245", + stInOutSensor := "DB_Inputs".Sensors["cInBG3245"]); + // MT in Position (ILS-CV M2105) + #fbSensorInput(stInSensorHW := "BG3247", + nInSensorNo := "cInBG3247", + stInOutSensor := "DB_Inputs".Sensors["cInBG3247"]); + // in Separator 1 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3270", + nInSensorNo := "cInBG3270", + stInOutSensor := "DB_Inputs".Sensors["cInBG3270"]); + // in Separator 2 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3271", + nInSensorNo := "cInBG3271", + stInOutSensor := "DB_Inputs".Sensors["cInBG3271"]); + // in Separator 3 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3272", + nInSensorNo := "cInBG3272", + stInOutSensor := "DB_Inputs".Sensors["cInBG3272"]); + // in Separator 4 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3273", + nInSensorNo := "cInBG3273", + stInOutSensor := "DB_Inputs".Sensors["cInBG3273"]); + // in Separator 5 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3274", + nInSensorNo := "cInBG3274", + stInOutSensor := "DB_Inputs".Sensors["cInBG3274"]); + // in Separator 6 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3275", + nInSensorNo := "cInBG3275", + stInOutSensor := "DB_Inputs".Sensors["cInBG3275"]); + // in Separator 7 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3276", + nInSensorNo := "cInBG3276", + stInOutSensor := "DB_Inputs".Sensors["cInBG3276"]); + // in Separator 8 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3277", + nInSensorNo := "cInBG3277", + stInOutSensor := "DB_Inputs".Sensors["cInBG3277"]); + // in Separator 9 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3280", + nInSensorNo := "cInBG3280", + stInOutSensor := "DB_Inputs".Sensors["cInBG3280"]); + // in Separator 10 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3281", + nInSensorNo := "cInBG3281", + stInOutSensor := "DB_Inputs".Sensors["cInBG3281"]); + // in Separator 11 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3282", + nInSensorNo := "cInBG3282", + stInOutSensor := "DB_Inputs".Sensors["cInBG3282"]); + // in Separator 12 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3283", + nInSensorNo := "cInBG3283", + stInOutSensor := "DB_Inputs".Sensors["cInBG3283"]); + // in Separator 13 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3284", + nInSensorNo := "cInBG3284", + stInOutSensor := "DB_Inputs".Sensors["cInBG3284"]); + // in Separator 14 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3285", + nInSensorNo := "cInBG3285", + stInOutSensor := "DB_Inputs".Sensors["cInBG3285"]); + // in Separator 15 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3286", + nInSensorNo := "cInBG3286", + stInOutSensor := "DB_Inputs".Sensors["cInBG3286"]); + // in Separator 16 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3287", + nInSensorNo := "cInBG3287", + stInOutSensor := "DB_Inputs".Sensors["cInBG3287"]); + // in Separator 17 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3290", + nInSensorNo := "cInBG3290", + stInOutSensor := "DB_Inputs".Sensors["cInBG3290"]); + // in Separator 18 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3291", + nInSensorNo := "cInBG3291", + stInOutSensor := "DB_Inputs".Sensors["cInBG3291"]); + // In Separator 19 (Block 2.1.1) + #fbSensorInput(stInSensorHW := "BG3292", + nInSensorNo := "cInBG3292", + stInOutSensor := "DB_Inputs".Sensors["cInBG3292"]); + // in Separator 1 (KR-M2103 Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3300", + nInSensorNo := "cInBG3300", + stInOutSensor := "DB_Inputs".Sensors["cInBG3300"]); + // Staumelder, Einfahrt (ILS-CV M2106) + #fbSensorInput(stInSensorHW := "BG3301", + nInSensorNo := "cInBG3301", + stInOutSensor := "DB_Inputs".Sensors["cInBG3301"]); + // Stausensor 1 (KR-M2103 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3302", + nInSensorNo := "cInBG3302", + stInOutSensor := "DB_Inputs".Sensors["cInBG3302"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2106) + #fbSensorInput(stInSensorHW := "BG3303", + nInSensorNo := "cInBG3303", + stInOutSensor := "DB_Inputs".Sensors["cInBG3303"]); + // in Separator (ILS-CV M2106) + #fbSensorInput(stInSensorHW := "BG3304", + nInSensorNo := "cInBG3304", + stInOutSensor := "DB_Inputs".Sensors["cInBG3304"]); + // Stausensor 2 (KR-M2103) + #fbSensorInput(stInSensorHW := "BG3305", + nInSensorNo := "cInBG3305", + stInOutSensor := "DB_Inputs".Sensors["cInBG3305"]); + // Rad dreht (KR-M2103) + #fbSensorInput(stInSensorHW := "BG3306", + nInSensorNo := "cInBG3306", + stInOutSensor := "DB_Inputs".Sensors["cInBG3306"]); + // MT in Position (ILS-CV M2106) + #fbSensorInput(stInSensorHW := "BG3307", + nInSensorNo := "cInBG3307", + stInOutSensor := "DB_Inputs".Sensors["cInBG3307"]); + // in Separator 1 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3330", + nInSensorNo := "cInBG3330", + stInOutSensor := "DB_Inputs".Sensors["cInBG3330"]); + // in Separator 2 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3331", + nInSensorNo := "cInBG3331", + stInOutSensor := "DB_Inputs".Sensors["cInBG3331"]); + // in Separator 3 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3332", + nInSensorNo := "cInBG3332", + stInOutSensor := "DB_Inputs".Sensors["cInBG3332"]); + // in Separator 4 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3333", + nInSensorNo := "cInBG3333", + stInOutSensor := "DB_Inputs".Sensors["cInBG3333"]); + // in Separator 5 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3334", + nInSensorNo := "cInBG3334", + stInOutSensor := "DB_Inputs".Sensors["cInBG3334"]); + // in Separator 6 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3335", + nInSensorNo := "cInBG3335", + stInOutSensor := "DB_Inputs".Sensors["cInBG3335"]); + // in Separator 7 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3336", + nInSensorNo := "cInBG3336", + stInOutSensor := "DB_Inputs".Sensors["cInBG3336"]); + // in Separator 8 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3337", + nInSensorNo := "cInBG3337", + stInOutSensor := "DB_Inputs".Sensors["cInBG3337"]); + // in Separator 9 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3340", + nInSensorNo := "cInBG3340", + stInOutSensor := "DB_Inputs".Sensors["cInBG3340"]); + // in Separator 10 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3341", + nInSensorNo := "cInBG3341", + stInOutSensor := "DB_Inputs".Sensors["cInBG3341"]); + // in Separator 11 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3342", + nInSensorNo := "cInBG3342", + stInOutSensor := "DB_Inputs".Sensors["cInBG3342"]); + // in Separator 12 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3343", + nInSensorNo := "cInBG3343", + stInOutSensor := "DB_Inputs".Sensors["cInBG3343"]); + // in Separator 13 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3344", + nInSensorNo := "cInBG3344", + stInOutSensor := "DB_Inputs".Sensors["cInBG3344"]); + // in Separator 14 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3345", + nInSensorNo := "cInBG3345", + stInOutSensor := "DB_Inputs".Sensors["cInBG3345"]); + // in Separator 15 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3346", + nInSensorNo := "cInBG3346", + stInOutSensor := "DB_Inputs".Sensors["cInBG3346"]); + // in Separator 16 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3347", + nInSensorNo := "cInBG3347", + stInOutSensor := "DB_Inputs".Sensors["cInBG3347"]); + // in Separator 17 (Block 2.1.2) + #fbSensorInput(stInSensorHW := "BG3350", + nInSensorNo := "cInBG3350", + stInOutSensor := "DB_Inputs".Sensors["cInBG3350"]); + // in Separator 1 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3360", + nInSensorNo := "cInBG3360", + stInOutSensor := "DB_Inputs".Sensors["cInBG3360"]); + // Staumelder, Einfahrt (ILS-CV M2107) + #fbSensorInput(stInSensorHW := "BG3361", + nInSensorNo := "cInBG3361", + stInOutSensor := "DB_Inputs".Sensors["cInBG3361"]); + // Stausensor 1 (KR-M2104 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3362", + nInSensorNo := "cInBG3362", + stInOutSensor := "DB_Inputs".Sensors["cInBG3362"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2107) + #fbSensorInput(stInSensorHW := "BG3363", + nInSensorNo := "cInBG3363", + stInOutSensor := "DB_Inputs".Sensors["cInBG3363"]); + // in Separator (ILS-CV M2107) + #fbSensorInput(stInSensorHW := "BG3364", + nInSensorNo := "cInBG3364", + stInOutSensor := "DB_Inputs".Sensors["cInBG3364"]); + // Stausensor (ILS-KR-M2104) + #fbSensorInput(stInSensorHW := "BG3365", + nInSensorNo := "cInBG3365", + stInOutSensor := "DB_Inputs".Sensors["cInBG3365"]); + // MT in Position (ILS-CV M2107) + #fbSensorInput(stInSensorHW := "BG3367", + nInSensorNo := "cInBG3367", + stInOutSensor := "DB_Inputs".Sensors["cInBG3367"]); + // in Separator 1 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3390", + nInSensorNo := "cInBG3390", + stInOutSensor := "DB_Inputs".Sensors["cInBG3390"]); + // in Separator 2 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3391", + nInSensorNo := "cInBG3391", + stInOutSensor := "DB_Inputs".Sensors["cInBG3391"]); + // in Separator 3 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3392", + nInSensorNo := "cInBG3392", + stInOutSensor := "DB_Inputs".Sensors["cInBG3392"]); + // in Separator 4 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3393", + nInSensorNo := "cInBG3393", + stInOutSensor := "DB_Inputs".Sensors["cInBG3393"]); + // in Separator 5 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3394", + nInSensorNo := "cInBG3394", + stInOutSensor := "DB_Inputs".Sensors["cInBG3394"]); + // in Separator 6 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3395", + nInSensorNo := "cInBG3395", + stInOutSensor := "DB_Inputs".Sensors["cInBG3395"]); + // in Separator 7 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3396", + nInSensorNo := "cInBG3396", + stInOutSensor := "DB_Inputs".Sensors["cInBG3396"]); + // in Separator 8 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3397", + nInSensorNo := "cInBG3397", + stInOutSensor := "DB_Inputs".Sensors["cInBG3397"]); + // in Separator 9 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3400", + nInSensorNo := "cInBG3400", + stInOutSensor := "DB_Inputs".Sensors["cInBG3400"]); + // in Separator 10 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3401", + nInSensorNo := "cInBG3401", + stInOutSensor := "DB_Inputs".Sensors["cInBG3401"]); + // in Separator 11 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3402", + nInSensorNo := "cInBG3402", + stInOutSensor := "DB_Inputs".Sensors["cInBG3402"]); + // in Separator 12 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3403", + nInSensorNo := "cInBG3403", + stInOutSensor := "DB_Inputs".Sensors["cInBG3403"]); + // in Separator 13 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3404", + nInSensorNo := "cInBG3404", + stInOutSensor := "DB_Inputs".Sensors["cInBG3404"]); + // in Separator 14 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3405", + nInSensorNo := "cInBG3405", + stInOutSensor := "DB_Inputs".Sensors["cInBG3405"]); + // in Separator 15 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3406", + nInSensorNo := "cInBG3406", + stInOutSensor := "DB_Inputs".Sensors["cInBG3406"]); + // in Separator 16 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3407", + nInSensorNo := "cInBG3407", + stInOutSensor := "DB_Inputs".Sensors["cInBG3407"]); + // in Separator 17 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3410", + nInSensorNo := "cInBG3410", + stInOutSensor := "DB_Inputs".Sensors["cInBG3410"]); + // in Separator 18 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3411", + nInSensorNo := "cInBG3411", + stInOutSensor := "DB_Inputs".Sensors["cInBG3411"]); + // in Separator 19 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3412", + nInSensorNo := "cInBG3412", + stInOutSensor := "DB_Inputs".Sensors["cInBG3412"]); + // in Separator 20 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3413", + nInSensorNo := "cInBG3413", + stInOutSensor := "DB_Inputs".Sensors["cInBG3413"]); + // in Separator 21 (Block 2.1.3) + #fbSensorInput(stInSensorHW := "BG3414", + nInSensorNo := "cInBG3414", + stInOutSensor := "DB_Inputs".Sensors["cInBG3414"]); + // in Separator 1 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3420", + nInSensorNo := "cInBG3420", + stInOutSensor := "DB_Inputs".Sensors["cInBG3420"]); + // Staumelder, Einfahrt (ILS-CV M2108) + #fbSensorInput(stInSensorHW := "BG3421", + nInSensorNo := "cInBG3421", + stInOutSensor := "DB_Inputs".Sensors["cInBG3421"]); + // Stausensor 1 (KR-M2104 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3422", + nInSensorNo := "cInBG3422", + stInOutSensor := "DB_Inputs".Sensors["cInBG3422"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2108) + #fbSensorInput(stInSensorHW := "BG3423", + nInSensorNo := "cInBG3423", + stInOutSensor := "DB_Inputs".Sensors["cInBG3423"]); + // in Separator (ILS-CV M2108) + #fbSensorInput(stInSensorHW := "BG3424", + nInSensorNo := "cInBG3424", + stInOutSensor := "DB_Inputs".Sensors["cInBG3424"]); + // in Separator 3 (ILS-CV M2104 Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3425", + nInSensorNo := "cInBG3425", + stInOutSensor := "DB_Inputs".Sensors["cInBG3425"]); + // Stausensor 1 (M2104) + #fbSensorInput(stInSensorHW := "BG3426", + nInSensorNo := "cInBG3426", + stInOutSensor := "DB_Inputs".Sensors["cInBG3426"]); + // MT in Position (ILS-CV M2108) + #fbSensorInput(stInSensorHW := "BG3427", + nInSensorNo := "cInBG3427", + stInOutSensor := "DB_Inputs".Sensors["cInBG3427"]); + // in Separator 4 (ILS-CV M2104 Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3431", + nInSensorNo := "cInBG3431", + stInOutSensor := "DB_Inputs".Sensors["cInBG3431"]); + // in Separator 1 (ILS-CV M2109 Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3432", + nInSensorNo := "cInBG3432", + stInOutSensor := "DB_Inputs".Sensors["cInBG3432"]); + // Sensor Förderer voll (ILS-CV 2109) + #fbSensorInput(stInSensorHW := "BG3433", + nInSensorNo := "cInBG3433", + stInOutSensor := "DB_Inputs".Sensors["cInBG3433"]); + // Stausensor 1 (M2109) + #fbSensorInput(stInSensorHW := "BG3434", + nInSensorNo := "cInBG3434", + stInOutSensor := "DB_Inputs".Sensors["cInBG3434"]); + // Stausensor 2 (KR-M2109) + #fbSensorInput(stInSensorHW := "BG3435", + nInSensorNo := "cInBG3435", + stInOutSensor := "DB_Inputs".Sensors["cInBG3435"]); + // Rad dreht (KR-M2104) + #fbSensorInput(stInSensorHW := "BG3436", + nInSensorNo := "cInBG3436", + stInOutSensor := "DB_Inputs".Sensors["cInBG3436"]); + // Stausensor Einfahrt Varioförderer (M1401) + #fbSensorInput(stInSensorHW := "BG3437", + nInSensorNo := "cInBG3437", + stInOutSensor := "DB_Inputs".Sensors["cInBG3437"]); + // in Separator (ILS-CV M2109) + #fbSensorInput(stInSensorHW := "BG3440", + nInSensorNo := "cInBG3440", + stInOutSensor := "DB_Inputs".Sensors["cInBG3440"]); + // MT in Position (ILS-CV M2109) + #fbSensorInput(stInSensorHW := "BG3441", + nInSensorNo := "cInBG3441", + stInOutSensor := "DB_Inputs".Sensors["cInBG3441"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2109) + #fbSensorInput(stInSensorHW := "BG3442", + nInSensorNo := "cInBG3442", + stInOutSensor := "DB_Inputs".Sensors["cInBG3442"]); + // in Separator 1 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3450", + nInSensorNo := "cInBG3450", + stInOutSensor := "DB_Inputs".Sensors["cInBG3450"]); + // in Separator 2 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3451", + nInSensorNo := "cInBG3451", + stInOutSensor := "DB_Inputs".Sensors["cInBG3451"]); + // in Separator 3 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3452", + nInSensorNo := "cInBG3452", + stInOutSensor := "DB_Inputs".Sensors["cInBG3452"]); + // in Separator 4 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3453", + nInSensorNo := "cInBG3453", + stInOutSensor := "DB_Inputs".Sensors["cInBG3453"]); + // in Separator 5 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3454", + nInSensorNo := "cInBG3454", + stInOutSensor := "DB_Inputs".Sensors["cInBG3454"]); + // in Separator 6 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3455", + nInSensorNo := "cInBG3455", + stInOutSensor := "DB_Inputs".Sensors["cInBG3455"]); + // in Separator 7 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3456", + nInSensorNo := "cInBG3456", + stInOutSensor := "DB_Inputs".Sensors["cInBG3456"]); + // in Separator 8 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3457", + nInSensorNo := "cInBG3457", + stInOutSensor := "DB_Inputs".Sensors["cInBG3457"]); + // in Separator 9 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3460", + nInSensorNo := "cInBG3460", + stInOutSensor := "DB_Inputs".Sensors["cInBG3460"]); + // in Separator 10 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3461", + nInSensorNo := "cInBG3461", + stInOutSensor := "DB_Inputs".Sensors["cInBG3461"]); + // in Separator 11 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3462", + nInSensorNo := "cInBG3462", + stInOutSensor := "DB_Inputs".Sensors["cInBG3462"]); + // in Separator 12 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3463", + nInSensorNo := "cInBG3463", + stInOutSensor := "DB_Inputs".Sensors["cInBG3463"]); + // in Separator 13 (Block 2.1.4) + #fbSensorInput(stInSensorHW := "BG3464", + nInSensorNo := "cInBG3464", + stInOutSensor := "DB_Inputs".Sensors["cInBG3464"]); + // in Separator 2 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3480", + nInSensorNo := "cInBG3480", + stInOutSensor := "DB_Inputs".Sensors["cInBG3480"]); + // Pin Abfrage (KR-M2201 ) Block 2.2.1 + #fbSensorInput(stInSensorHW := "BG3481", + nInSensorNo := "cInBG3481", + stInOutSensor := "DB_Inputs".Sensors["cInBG3481"]); + // Prüfung MT Pos.1 (KR-K2201 Einfahrt Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3482", + nInSensorNo := "cInBG3482", + stInOutSensor := "DB_Inputs".Sensors["cInBG3482"]); + // Stausensor (KR-M2201) Block 2.2.1 + #fbSensorInput(stInSensorHW := "BG3483", + nInSensorNo := "cInBG3483", + stInOutSensor := "DB_Inputs".Sensors["cInBG3483"]); + // in Separator 1 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3484", + nInSensorNo := "cInBG3484", + stInOutSensor := "DB_Inputs".Sensors["cInBG3484"]); + // Stausensor Str.1 (KR-K2205 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3485", + nInSensorNo := "cInBG3485", + stInOutSensor := "DB_Inputs".Sensors["cInBG3485"]); + // Sensor Förderer voll (ILS-CV M2205) + #fbSensorInput(stInSensorHW := "BG3486", + nInSensorNo := "cInBG3486", + stInOutSensor := "DB_Inputs".Sensors["cInBG3486"]); + // Prüfung MT Pos.2 (KR-K2201 Einfahrt Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3487", + nInSensorNo := "cInBG3487", + stInOutSensor := "DB_Inputs".Sensors["cInBG3487"]); + // Prüfung MT Pos.3 (KR-K2201 Einfahrt Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3490", + nInSensorNo := "cInBG3490", + stInOutSensor := "DB_Inputs".Sensors["cInBG3490"]); + // Prüfung MT Pos.4 (KR-K2201 Einfahrt Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3491", + nInSensorNo := "cInBG3491", + stInOutSensor := "DB_Inputs".Sensors["cInBG3491"]); + // Stausensor Str.1 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3510", + nInSensorNo := "cInBG3510", + stInOutSensor := "DB_Inputs".Sensors["cInBG3510"]); + // Stausensor Str.2 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3511", + nInSensorNo := "cInBG3511", + stInOutSensor := "DB_Inputs".Sensors["cInBG3511"]); + // Stausensor Str.3 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3512", + nInSensorNo := "cInBG3512", + stInOutSensor := "DB_Inputs".Sensors["cInBG3512"]); + // Stausensor Str.4 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3513", + nInSensorNo := "cInBG3513", + stInOutSensor := "DB_Inputs".Sensors["cInBG3513"]); + // Stausensor Str.5 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3514", + nInSensorNo := "cInBG3514", + stInOutSensor := "DB_Inputs".Sensors["cInBG3514"]); + // Stausensor Str.6 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3515", + nInSensorNo := "cInBG3515", + stInOutSensor := "DB_Inputs".Sensors["cInBG3515"]); + // Stausensor Str.7 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3516", + nInSensorNo := "cInBG3516", + stInOutSensor := "DB_Inputs".Sensors["cInBG3516"]); + // Stausensor Str.8 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3517", + nInSensorNo := "cInBG3517", + stInOutSensor := "DB_Inputs".Sensors["cInBG3517"]); + // Stausensor Str.9 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3520", + nInSensorNo := "cInBG3520", + stInOutSensor := "DB_Inputs".Sensors["cInBG3520"]); + // Stausensor Str.10 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3521", + nInSensorNo := "cInBG3521", + stInOutSensor := "DB_Inputs".Sensors["cInBG3521"]); + // Stausensor Str.11 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3522", + nInSensorNo := "cInBG3522", + stInOutSensor := "DB_Inputs".Sensors["cInBG3522"]); + // Stausensor Str.12 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3523", + nInSensorNo := "cInBG3523", + stInOutSensor := "DB_Inputs".Sensors["cInBG3523"]); + // Stausensor Str.13 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3524", + nInSensorNo := "cInBG3524", + stInOutSensor := "DB_Inputs".Sensors["cInBG3524"]); + // in Separator 2 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3540", + nInSensorNo := "cInBG3540", + stInOutSensor := "DB_Inputs".Sensors["cInBG3540"]); + // Pin Abfrage (KR-M2201 ) Block 2.2.2 + #fbSensorInput(stInSensorHW := "BG3541", + nInSensorNo := "cInBG3541", + stInOutSensor := "DB_Inputs".Sensors["cInBG3541"]); + // Prüfung MT Pos.1 (KR-K2201 Einfahrt Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3542", + nInSensorNo := "cInBG3542", + stInOutSensor := "DB_Inputs".Sensors["cInBG3542"]); + // Stausensor Str.2 (KR-M2201) + #fbSensorInput(stInSensorHW := "BG3543", + nInSensorNo := "cInBG3543", + stInOutSensor := "DB_Inputs".Sensors["cInBG3543"]); + // in Separator 1 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3544", + nInSensorNo := "cInBG3544", + stInOutSensor := "DB_Inputs".Sensors["cInBG3544"]); + // Stausensor Str.1 (KR-K2206 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3545", + nInSensorNo := "cInBG3545", + stInOutSensor := "DB_Inputs".Sensors["cInBG3545"]); + // Sensor Förderer voll (ILS-CV M2206) + #fbSensorInput(stInSensorHW := "BG3546", + nInSensorNo := "cInBG3546", + stInOutSensor := "DB_Inputs".Sensors["cInBG3546"]); + // Prüfung MT Pos.2 (KR-K2201 Einfahrt Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3547", + nInSensorNo := "cInBG3547", + stInOutSensor := "DB_Inputs".Sensors["cInBG3547"]); + // Prüfung MT Pos.3 (KR-K2201 Einfahrt Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3550", + nInSensorNo := "cInBG3550", + stInOutSensor := "DB_Inputs".Sensors["cInBG3550"]); + // Prüfung MT Pos.4 (KR-K2201 Einfahrt Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3551", + nInSensorNo := "cInBG3551", + stInOutSensor := "DB_Inputs".Sensors["cInBG3551"]); + // Prüfung MT Pos.5 (KR-K2201 Einfahrt Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3552", + nInSensorNo := "cInBG3552", + stInOutSensor := "DB_Inputs".Sensors["cInBG3552"]); + // Stausensor MT vor Pinband (KR-M2201) Block 2.2.2 + #fbSensorInput(stInSensorHW := "BG3553", + nInSensorNo := "cInBG3553", + stInOutSensor := "DB_Inputs".Sensors["cInBG3553"]); + // Stausensor Str.1 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3570", + nInSensorNo := "cInBG3570", + stInOutSensor := "DB_Inputs".Sensors["cInBG3570"]); + // Stausensor Str.2 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3571", + nInSensorNo := "cInBG3571", + stInOutSensor := "DB_Inputs".Sensors["cInBG3571"]); + // Stausensor Str.3 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3572", + nInSensorNo := "cInBG3572", + stInOutSensor := "DB_Inputs".Sensors["cInBG3572"]); + // Stausensor Str.4 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3573", + nInSensorNo := "cInBG3573", + stInOutSensor := "DB_Inputs".Sensors["cInBG3573"]); + // Stausensor Str.5 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3574", + nInSensorNo := "cInBG3574", + stInOutSensor := "DB_Inputs".Sensors["cInBG3574"]); + // Stausensor Str.6 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3575", + nInSensorNo := "cInBG3575", + stInOutSensor := "DB_Inputs".Sensors["cInBG3575"]); + // Stausensor Str.7 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3576", + nInSensorNo := "cInBG3576", + stInOutSensor := "DB_Inputs".Sensors["cInBG3576"]); + // Stausensor Str.8 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3577", + nInSensorNo := "cInBG3577", + stInOutSensor := "DB_Inputs".Sensors["cInBG3577"]); + // Stausensor Str.9 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3580", + nInSensorNo := "cInBG3580", + stInOutSensor := "DB_Inputs".Sensors["cInBG3580"]); + // Stausensor Str.10 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3581", + nInSensorNo := "cInBG3581", + stInOutSensor := "DB_Inputs".Sensors["cInBG3581"]); + // Stausensor Str.11 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3582", + nInSensorNo := "cInBG3582", + stInOutSensor := "DB_Inputs".Sensors["cInBG3582"]); + // Stausensor Str.12 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3583", + nInSensorNo := "cInBG3583", + stInOutSensor := "DB_Inputs".Sensors["cInBG3583"]); + // Stausensor Str.13 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3584", + nInSensorNo := "cInBG3584", + stInOutSensor := "DB_Inputs".Sensors["cInBG3584"]); + // Stausensor Str.14 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3585", + nInSensorNo := "cInBG3585", + stInOutSensor := "DB_Inputs".Sensors["cInBG3585"]); + // Stausensor Str.15 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3586", + nInSensorNo := "cInBG3586", + stInOutSensor := "DB_Inputs".Sensors["cInBG3586"]); + // Stausensor Str.16 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3587", + nInSensorNo := "cInBG3587", + stInOutSensor := "DB_Inputs".Sensors["cInBG3587"]); + // Stausensor Str.17 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3590", + nInSensorNo := "cInBG3590", + stInOutSensor := "DB_Inputs".Sensors["cInBG3590"]); + // in Separator 2 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3600", + nInSensorNo := "cInBG3600", + stInOutSensor := "DB_Inputs".Sensors["cInBG3600"]); + // Pin Abfrage (KR-M2202 ) Block 2.2.3 + #fbSensorInput(stInSensorHW := "BG3601", + nInSensorNo := "cInBG3601", + stInOutSensor := "DB_Inputs".Sensors["cInBG3601"]); + // Prüfung MT Pos.1 (KR-K2202 Einfahrt Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3602", + nInSensorNo := "cInBG3602", + stInOutSensor := "DB_Inputs".Sensors["cInBG3602"]); + // Stausensor Str.2 (KR-M2202) + #fbSensorInput(stInSensorHW := "BG3603", + nInSensorNo := "cInBG3603", + stInOutSensor := "DB_Inputs".Sensors["cInBG3603"]); + // in Separator 1 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3604", + nInSensorNo := "cInBG3604", + stInOutSensor := "DB_Inputs".Sensors["cInBG3604"]); + // Stausensor Str.1 (KR-K2207 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3605", + nInSensorNo := "cInBG3605", + stInOutSensor := "DB_Inputs".Sensors["cInBG3605"]); + // Sensor Förderer voll (ILS-CV 2207) + #fbSensorInput(stInSensorHW := "BG3606", + nInSensorNo := "cInBG3606", + stInOutSensor := "DB_Inputs".Sensors["cInBG3606"]); + // Prüfung MT Pos.2 (KR-K2202 Einfahrt Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3607", + nInSensorNo := "cInBG3607", + stInOutSensor := "DB_Inputs".Sensors["cInBG3607"]); + // Prüfung MT Pos.3 (KR-K2202 Einfahrt Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3610", + nInSensorNo := "cInBG3610", + stInOutSensor := "DB_Inputs".Sensors["cInBG3610"]); + // Prüfung MT Pos.4 (KR-K2202 Einfahrt Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3611", + nInSensorNo := "cInBG3611", + stInOutSensor := "DB_Inputs".Sensors["cInBG3611"]); + // Prüfung MT Pos.5 (KR-K2202 Einfahrt Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3612", + nInSensorNo := "cInBG3612", + stInOutSensor := "DB_Inputs".Sensors["cInBG3612"]); + // Prüfung MT Pos.6 (KR-K2202 Einfahrt Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3613", + nInSensorNo := "cInBG3613", + stInOutSensor := "DB_Inputs".Sensors["cInBG3613"]); + // in Separator 3 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3614", + nInSensorNo := "cInBG3614", + stInOutSensor := "DB_Inputs".Sensors["cInBG3614"]); + // Stausensor (ILS-CV M1209) + #fbSensorInput(stInSensorHW := "BG3615", + nInSensorNo := "cInBG3615", + stInOutSensor := "DB_Inputs".Sensors["cInBG3615"]); + // Stausensor 1 (KR-M2202) + #fbSensorInput(stInSensorHW := "BG3616", + nInSensorNo := "cInBG3616", + stInOutSensor := "DB_Inputs".Sensors["cInBG3616"]); + // in Separator 4 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3617", + nInSensorNo := "cInBG3617", + stInOutSensor := "DB_Inputs".Sensors["cInBG3617"]); + // Stausensor MT vor Pinband (KR-M2202) Block 2.2.3 + #fbSensorInput(stInSensorHW := "BG3625", + nInSensorNo := "cInBG3625", + stInOutSensor := "DB_Inputs".Sensors["cInBG3625"]); + // Stausensor Str.1 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3630", + nInSensorNo := "cInBG3630", + stInOutSensor := "DB_Inputs".Sensors["cInBG3630"]); + // Stausensor Str.2 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3631", + nInSensorNo := "cInBG3631", + stInOutSensor := "DB_Inputs".Sensors["cInBG3631"]); + // Stausensor Str.3 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3632", + nInSensorNo := "cInBG3632", + stInOutSensor := "DB_Inputs".Sensors["cInBG3632"]); + // Stausensor Str.4 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3633", + nInSensorNo := "cInBG3633", + stInOutSensor := "DB_Inputs".Sensors["cInBG3633"]); + // Stausensor Str.5 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3634", + nInSensorNo := "cInBG3634", + stInOutSensor := "DB_Inputs".Sensors["cInBG3634"]); + // Stausensor Str.6 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3635", + nInSensorNo := "cInBG3635", + stInOutSensor := "DB_Inputs".Sensors["cInBG3635"]); + // Stausensor Str.7 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3636", + nInSensorNo := "cInBG3636", + stInOutSensor := "DB_Inputs".Sensors["cInBG3636"]); + // Stausensor Str.8 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3637", + nInSensorNo := "cInBG3637", + stInOutSensor := "DB_Inputs".Sensors["cInBG3637"]); + // Stausensor Str.9 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3640", + nInSensorNo := "cInBG3640", + stInOutSensor := "DB_Inputs".Sensors["cInBG3640"]); + // Stausensor Str.10 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3641", + nInSensorNo := "cInBG3641", + stInOutSensor := "DB_Inputs".Sensors["cInBG3641"]); + // Stausensor Str.11 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3642", + nInSensorNo := "cInBG3642", + stInOutSensor := "DB_Inputs".Sensors["cInBG3642"]); + // Stausensor Str.12 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3643", + nInSensorNo := "cInBG3643", + stInOutSensor := "DB_Inputs".Sensors["cInBG3643"]); + // Stausensor Str.13 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3644", + nInSensorNo := "cInBG3644", + stInOutSensor := "DB_Inputs".Sensors["cInBG3644"]); + // Stausensor Str.14 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3645", + nInSensorNo := "cInBG3645", + stInOutSensor := "DB_Inputs".Sensors["cInBG3645"]); + // Stausensor Str.15 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3646", + nInSensorNo := "cInBG3646", + stInOutSensor := "DB_Inputs".Sensors["cInBG3646"]); + // Stausensor Str.16 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3647", + nInSensorNo := "cInBG3647", + stInOutSensor := "DB_Inputs".Sensors["cInBG3647"]); + // Stausensor Str.17 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3650", + nInSensorNo := "cInBG3650", + stInOutSensor := "DB_Inputs".Sensors["cInBG3650"]); + // Stausensor Str.18 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3651", + nInSensorNo := "cInBG3651", + stInOutSensor := "DB_Inputs".Sensors["cInBG3651"]); + // Stausensor Str.19 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3652", + nInSensorNo := "cInBG3652", + stInOutSensor := "DB_Inputs".Sensors["cInBG3652"]); + // Stausensor Str.20 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3653", + nInSensorNo := "cInBG3653", + stInOutSensor := "DB_Inputs".Sensors["cInBG3653"]); + // Stausensor Str.21 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3654", + nInSensorNo := "cInBG3654", + stInOutSensor := "DB_Inputs".Sensors["cInBG3654"]); + // in Separator 2 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3660", + nInSensorNo := "cInBG3660", + stInOutSensor := "DB_Inputs".Sensors["cInBG3660"]); + // Pin Abfrage (KR-M2202 ) Block 2.2.4 + #fbSensorInput(stInSensorHW := "BG3661", + nInSensorNo := "cInBG3661", + stInOutSensor := "DB_Inputs".Sensors["cInBG3661"]); + // Prüfung MT Pos.1 (KR-M2202 Einfahrt Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3662", + nInSensorNo := "cInBG3662", + stInOutSensor := "DB_Inputs".Sensors["cInBG3662"]); + // Stausensor Str.2 (KR-M2202) + #fbSensorInput(stInSensorHW := "BG3663", + nInSensorNo := "cInBG3663", + stInOutSensor := "DB_Inputs".Sensors["cInBG3663"]); + // in Separator 1 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3664", + nInSensorNo := "cInBG3664", + stInOutSensor := "DB_Inputs".Sensors["cInBG3664"]); + // Stausensor Str.1 (KR-K2208 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3665", + nInSensorNo := "cInBG3665", + stInOutSensor := "DB_Inputs".Sensors["cInBG3665"]); + // Sensor Förderer voll (ILS-CV 2208) + #fbSensorInput(stInSensorHW := "BG3666", + nInSensorNo := "cInBG3666", + stInOutSensor := "DB_Inputs".Sensors["cInBG3666"]); + // Prüfung MT Pos.2 (KR-M2202 Einfahrt Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3667", + nInSensorNo := "cInBG3667", + stInOutSensor := "DB_Inputs".Sensors["cInBG3667"]); + // Prüfung MT Pos.3 (KR-K2202 Einfahrt Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3670", + nInSensorNo := "cInBG3670", + stInOutSensor := "DB_Inputs".Sensors["cInBG3670"]); + // Prüfung MT Pos.4 (KR-M2202 Einfahrt Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3671", + nInSensorNo := "cInBG3671", + stInOutSensor := "DB_Inputs".Sensors["cInBG3671"]); + // in Separator 3 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3672", + nInSensorNo := "cInBG3672", + stInOutSensor := "DB_Inputs".Sensors["cInBG3672"]); + // Stausensor (KR-M2202) + #fbSensorInput(stInSensorHW := "BG3673", + nInSensorNo := "cInBG3673", + stInOutSensor := "DB_Inputs".Sensors["cInBG3673"]); + // Stausensor (KR-M2202) + #fbSensorInput(stInSensorHW := "BG3674", + nInSensorNo := "cInBG3674", + stInOutSensor := "DB_Inputs".Sensors["cInBG3674"]); + // Stausensor Str.1 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3690", + nInSensorNo := "cInBG3690", + stInOutSensor := "DB_Inputs".Sensors["cInBG3690"]); + // Stausensor Str.2 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3691", + nInSensorNo := "cInBG3691", + stInOutSensor := "DB_Inputs".Sensors["cInBG3691"]); + // Stausensor Str.3 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3692", + nInSensorNo := "cInBG3692", + stInOutSensor := "DB_Inputs".Sensors["cInBG3692"]); + // Stausensor Str.4 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3693", + nInSensorNo := "cInBG3693", + stInOutSensor := "DB_Inputs".Sensors["cInBG3693"]); + // Stausensor Str.5 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3694", + nInSensorNo := "cInBG3694", + stInOutSensor := "DB_Inputs".Sensors["cInBG3694"]); + // Stausensor Str.6 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3695", + nInSensorNo := "cInBG3695", + stInOutSensor := "DB_Inputs".Sensors["cInBG3695"]); + // Stausensor Str.7 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3696", + nInSensorNo := "cInBG3696", + stInOutSensor := "DB_Inputs".Sensors["cInBG3696"]); + // Stausensor Str.8 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3697", + nInSensorNo := "cInBG3697", + stInOutSensor := "DB_Inputs".Sensors["cInBG3697"]); + // Stausensor Str.9 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3700", + nInSensorNo := "cInBG3700", + stInOutSensor := "DB_Inputs".Sensors["cInBG3700"]); + // Stausensor Str.10 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3701", + nInSensorNo := "cInBG3701", + stInOutSensor := "DB_Inputs".Sensors["cInBG3701"]); + // Stausensor Str.11 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3702", + nInSensorNo := "cInBG3702", + stInOutSensor := "DB_Inputs".Sensors["cInBG3702"]); + // Stausensor Str.12 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3703", + nInSensorNo := "cInBG3703", + stInOutSensor := "DB_Inputs".Sensors["cInBG3703"]); + // Stausensor Str.13 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3704", + nInSensorNo := "cInBG3704", + stInOutSensor := "DB_Inputs".Sensors["cInBG3704"]); + // in Separator 1 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3720", + nInSensorNo := "cInBG3720", + stInOutSensor := "DB_Inputs".Sensors["cInBG3720"]); + // Staumelder, Einfahrt (ILS-CV M2205 Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3721", + nInSensorNo := "cInBG3721", + stInOutSensor := "DB_Inputs".Sensors["cInBG3721"]); + // Stausensor 1 (KR-M2203 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG3722", + nInSensorNo := "cInBG3722", + stInOutSensor := "DB_Inputs".Sensors["cInBG3722"]); + // Abfrage Mitnehmerfinger in Position (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3723", + nInSensorNo := "cInBG3723", + stInOutSensor := "DB_Inputs".Sensors["cInBG3723"]); + // in Separator 2 (ILS-CV M2205 Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3724", + nInSensorNo := "cInBG3724", + stInOutSensor := "DB_Inputs".Sensors["cInBG3724"]); + // in Separator (KR-M2203) + #fbSensorInput(stInSensorHW := "BG3725", + nInSensorNo := "cInBG3725", + stInOutSensor := "DB_Inputs".Sensors["cInBG3725"]); + // MT in Position (ILS-CV M2205) + #fbSensorInput(stInSensorHW := "BG3727", + nInSensorNo := "cInBG3727", + stInOutSensor := "DB_Inputs".Sensors["cInBG3727"]); + // in Separator 1 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3750", + nInSensorNo := "cInBG3750", + stInOutSensor := "DB_Inputs".Sensors["cInBG3750"]); + // in Separator 2 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3751", + nInSensorNo := "cInBG3751", + stInOutSensor := "DB_Inputs".Sensors["cInBG3751"]); + // in Separator 3 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3752", + nInSensorNo := "cInBG3752", + stInOutSensor := "DB_Inputs".Sensors["cInBG3752"]); + // in Separator 4 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3753", + nInSensorNo := "cInBG3753", + stInOutSensor := "DB_Inputs".Sensors["cInBG3753"]); + // in Separator 5 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3754", + nInSensorNo := "cInBG3754", + stInOutSensor := "DB_Inputs".Sensors["cInBG3754"]); + // in Separator 6 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3755", + nInSensorNo := "cInBG3755", + stInOutSensor := "DB_Inputs".Sensors["cInBG3755"]); + // in Separator 7 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3756", + nInSensorNo := "cInBG3756", + stInOutSensor := "DB_Inputs".Sensors["cInBG3756"]); + // in Separator 8 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3757", + nInSensorNo := "cInBG3757", + stInOutSensor := "DB_Inputs".Sensors["cInBG3757"]); + // in Separator 9 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3760", + nInSensorNo := "cInBG3760", + stInOutSensor := "DB_Inputs".Sensors["cInBG3760"]); + // in Separator 10 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3761", + nInSensorNo := "cInBG3761", + stInOutSensor := "DB_Inputs".Sensors["cInBG3761"]); + // in Separator 11 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3762", + nInSensorNo := "cInBG3762", + stInOutSensor := "DB_Inputs".Sensors["cInBG3762"]); + // in Separator 12 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3763", + nInSensorNo := "cInBG3763", + stInOutSensor := "DB_Inputs".Sensors["cInBG3763"]); + // in Separator 13 (Block 2.2.1) + #fbSensorInput(stInSensorHW := "BG3764", + nInSensorNo := "cInBG3764", + stInOutSensor := "DB_Inputs".Sensors["cInBG3764"]); + // in Separator 1 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3780", + nInSensorNo := "cInBG3780", + stInOutSensor := "DB_Inputs".Sensors["cInBG3780"]); + // Staumelder, Einfahrt (ILS-CV M2206) + #fbSensorInput(stInSensorHW := "BG3781", + nInSensorNo := "cInBG3781", + stInOutSensor := "DB_Inputs".Sensors["cInBG3781"]); + // Stausensor (KR-M2203) + #fbSensorInput(stInSensorHW := "BG3782", + nInSensorNo := "cInBG3782", + stInOutSensor := "DB_Inputs".Sensors["cInBG3782"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2206) + #fbSensorInput(stInSensorHW := "BG3783", + nInSensorNo := "cInBG3783", + stInOutSensor := "DB_Inputs".Sensors["cInBG3783"]); + // in Separator (ILS-CV M2206) + #fbSensorInput(stInSensorHW := "BG3784", + nInSensorNo := "cInBG3784", + stInOutSensor := "DB_Inputs".Sensors["cInBG3784"]); + // Stausensor 3 (KR-M2203) + #fbSensorInput(stInSensorHW := "BG3785", + nInSensorNo := "cInBG3785", + stInOutSensor := "DB_Inputs".Sensors["cInBG3785"]); + // Rad dreht (KR-M2203) + #fbSensorInput(stInSensorHW := "BG3786", + nInSensorNo := "cInBG3786", + stInOutSensor := "DB_Inputs".Sensors["cInBG3786"]); + // MT in Position (ILS-CV M2206) + #fbSensorInput(stInSensorHW := "BG3787", + nInSensorNo := "cInBG3787", + stInOutSensor := "DB_Inputs".Sensors["cInBG3787"]); + // in Separator 1 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3810", + nInSensorNo := "cInBG3810", + stInOutSensor := "DB_Inputs".Sensors["cInBG3810"]); + // in Separator 2 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3811", + nInSensorNo := "cInBG3811", + stInOutSensor := "DB_Inputs".Sensors["cInBG3811"]); + // in Separator 3 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3812", + nInSensorNo := "cInBG3812", + stInOutSensor := "DB_Inputs".Sensors["cInBG3812"]); + // in Separator 4 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3813", + nInSensorNo := "cInBG3813", + stInOutSensor := "DB_Inputs".Sensors["cInBG3813"]); + // in Separator 5 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3814", + nInSensorNo := "cInBG3814", + stInOutSensor := "DB_Inputs".Sensors["cInBG3814"]); + // in Separator 6 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3815", + nInSensorNo := "cInBG3815", + stInOutSensor := "DB_Inputs".Sensors["cInBG3815"]); + // in Separator 7 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3816", + nInSensorNo := "cInBG3816", + stInOutSensor := "DB_Inputs".Sensors["cInBG3816"]); + // in Separator 8 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3817", + nInSensorNo := "cInBG3817", + stInOutSensor := "DB_Inputs".Sensors["cInBG3817"]); + // in Separator 9 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3820", + nInSensorNo := "cInBG3820", + stInOutSensor := "DB_Inputs".Sensors["cInBG3820"]); + // in Separator 10 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3821", + nInSensorNo := "cInBG3821", + stInOutSensor := "DB_Inputs".Sensors["cInBG3821"]); + // in Separator 11 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3822", + nInSensorNo := "cInBG3822", + stInOutSensor := "DB_Inputs".Sensors["cInBG3822"]); + // in Separator 12 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3823", + nInSensorNo := "cInBG3823", + stInOutSensor := "DB_Inputs".Sensors["cInBG3823"]); + // in Separator 13 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3824", + nInSensorNo := "cInBG3824", + stInOutSensor := "DB_Inputs".Sensors["cInBG3824"]); + // in Separator 14 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3825", + nInSensorNo := "cInBG3825", + stInOutSensor := "DB_Inputs".Sensors["cInBG3825"]); + // in Separator 15 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3826", + nInSensorNo := "cInBG3826", + stInOutSensor := "DB_Inputs".Sensors["cInBG3826"]); + // in Separator 16 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3827", + nInSensorNo := "cInBG3827", + stInOutSensor := "DB_Inputs".Sensors["cInBG3827"]); + // in Separator 17 (Block 2.2.2) + #fbSensorInput(stInSensorHW := "BG3830", + nInSensorNo := "cInBG3830", + stInOutSensor := "DB_Inputs".Sensors["cInBG3830"]); + // in Separator 1 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3840", + nInSensorNo := "cInBG3840", + stInOutSensor := "DB_Inputs".Sensors["cInBG3840"]); + // Staumelder, Einfahrt (ILS-CV M2207) + #fbSensorInput(stInSensorHW := "BG3841", + nInSensorNo := "cInBG3841", + stInOutSensor := "DB_Inputs".Sensors["cInBG3841"]); + // Stausensor (KR-M2204) + #fbSensorInput(stInSensorHW := "BG3842", + nInSensorNo := "cInBG3842", + stInOutSensor := "DB_Inputs".Sensors["cInBG3842"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2207) + #fbSensorInput(stInSensorHW := "BG3843", + nInSensorNo := "cInBG3843", + stInOutSensor := "DB_Inputs".Sensors["cInBG3843"]); + // in Separator (ILS-CV M2207) + #fbSensorInput(stInSensorHW := "BG3844", + nInSensorNo := "cInBG3844", + stInOutSensor := "DB_Inputs".Sensors["cInBG3844"]); + // Stausensor (KR-M2204) + #fbSensorInput(stInSensorHW := "BG3845", + nInSensorNo := "cInBG3845", + stInOutSensor := "DB_Inputs".Sensors["cInBG3845"]); + // MT in Position (ILS-CV M2207) + #fbSensorInput(stInSensorHW := "BG3847", + nInSensorNo := "cInBG3847", + stInOutSensor := "DB_Inputs".Sensors["cInBG3847"]); + // in Separator 1 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3870", + nInSensorNo := "cInBG3870", + stInOutSensor := "DB_Inputs".Sensors["cInBG3870"]); + // in Separator 2 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3871", + nInSensorNo := "cInBG3871", + stInOutSensor := "DB_Inputs".Sensors["cInBG3871"]); + // in Separator 3 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3872", + nInSensorNo := "cInBG3872", + stInOutSensor := "DB_Inputs".Sensors["cInBG3872"]); + // in Separator 4 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3873", + nInSensorNo := "cInBG3873", + stInOutSensor := "DB_Inputs".Sensors["cInBG3873"]); + // in Separator 5 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3874", + nInSensorNo := "cInBG3874", + stInOutSensor := "DB_Inputs".Sensors["cInBG3874"]); + // in Separator 6 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3875", + nInSensorNo := "cInBG3875", + stInOutSensor := "DB_Inputs".Sensors["cInBG3875"]); + // in Separator 7 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3876", + nInSensorNo := "cInBG3876", + stInOutSensor := "DB_Inputs".Sensors["cInBG3876"]); + // in Separator 8 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3877", + nInSensorNo := "cInBG3877", + stInOutSensor := "DB_Inputs".Sensors["cInBG3877"]); + // in Separator 9 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3880", + nInSensorNo := "cInBG3880", + stInOutSensor := "DB_Inputs".Sensors["cInBG3880"]); + // in Separator 10 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3881", + nInSensorNo := "cInBG3881", + stInOutSensor := "DB_Inputs".Sensors["cInBG3881"]); + // in Separator 11 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3882", + nInSensorNo := "cInBG3882", + stInOutSensor := "DB_Inputs".Sensors["cInBG3882"]); + // in Separator 12 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3883", + nInSensorNo := "cInBG3883", + stInOutSensor := "DB_Inputs".Sensors["cInBG3883"]); + // in Separator 13 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3884", + nInSensorNo := "cInBG3884", + stInOutSensor := "DB_Inputs".Sensors["cInBG3884"]); + // in Separator 14 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3885", + nInSensorNo := "cInBG3885", + stInOutSensor := "DB_Inputs".Sensors["cInBG3885"]); + // in Separator 15 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3886", + nInSensorNo := "cInBG3886", + stInOutSensor := "DB_Inputs".Sensors["cInBG3886"]); + // in Separator 16 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3887", + nInSensorNo := "cInBG3887", + stInOutSensor := "DB_Inputs".Sensors["cInBG3887"]); + // in Separator 17 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3890", + nInSensorNo := "cInBG3890", + stInOutSensor := "DB_Inputs".Sensors["cInBG3890"]); + // in Separator 18 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3891", + nInSensorNo := "cInBG3891", + stInOutSensor := "DB_Inputs".Sensors["cInBG3891"]); + // in Separator 19 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3892", + nInSensorNo := "cInBG3892", + stInOutSensor := "DB_Inputs".Sensors["cInBG3892"]); + // in Separator 20 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3893", + nInSensorNo := "cInBG3893", + stInOutSensor := "DB_Inputs".Sensors["cInBG3893"]); + // in Separator 21 (Block 2.2.3) + #fbSensorInput(stInSensorHW := "BG3894", + nInSensorNo := "cInBG3894", + stInOutSensor := "DB_Inputs".Sensors["cInBG3894"]); + // in Separator (ILS-KR M2204) + #fbSensorInput(stInSensorHW := "BG3900", + nInSensorNo := "cInBG3900", + stInOutSensor := "DB_Inputs".Sensors["cInBG3900"]); + // Staumelder, Einfahrt (ILS-CV M2208)) + #fbSensorInput(stInSensorHW := "BG3901", + nInSensorNo := "cInBG3901", + stInOutSensor := "DB_Inputs".Sensors["cInBG3901"]); + // Stausensor (KR-M2204) + #fbSensorInput(stInSensorHW := "BG3902", + nInSensorNo := "cInBG3902", + stInOutSensor := "DB_Inputs".Sensors["cInBG3902"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2208) + #fbSensorInput(stInSensorHW := "BG3903", + nInSensorNo := "cInBG3903", + stInOutSensor := "DB_Inputs".Sensors["cInBG3903"]); + // in Separator (ILS-CV M2208) + #fbSensorInput(stInSensorHW := "BG3904", + nInSensorNo := "cInBG3904", + stInOutSensor := "DB_Inputs".Sensors["cInBG3904"]); + // in Separator 3 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3905", + nInSensorNo := "cInBG3905", + stInOutSensor := "DB_Inputs".Sensors["cInBG3905"]); + // Stausensor 1 (KR-M2204) + #fbSensorInput(stInSensorHW := "BG3906", + nInSensorNo := "cInBG3906", + stInOutSensor := "DB_Inputs".Sensors["cInBG3906"]); + // MT in Position (ILS-CV M2208) + #fbSensorInput(stInSensorHW := "BG3907", + nInSensorNo := "cInBG3907", + stInOutSensor := "DB_Inputs".Sensors["cInBG3907"]); + // in Separator 4 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3910", + nInSensorNo := "cInBG3910", + stInOutSensor := "DB_Inputs".Sensors["cInBG3910"]); + // Stausensor Einfahrt Varioförderer (M1501) + #fbSensorInput(stInSensorHW := "BG3911", + nInSensorNo := "cInBG3911", + stInOutSensor := "DB_Inputs".Sensors["cInBG3911"]); + // in Separator 5 (ILS-CV M2209) + #fbSensorInput(stInSensorHW := "BG3912", + nInSensorNo := "cInBG3912", + stInOutSensor := "DB_Inputs".Sensors["cInBG3912"]); + // Sensor Förderer voll (ILS-CV 2209) + #fbSensorInput(stInSensorHW := "BG3913", + nInSensorNo := "cInBG3913", + stInOutSensor := "DB_Inputs".Sensors["cInBG3913"]); + // Stausensor (ILS-CV M2209) + #fbSensorInput(stInSensorHW := "BG3915", + nInSensorNo := "cInBG3915", + stInOutSensor := "DB_Inputs".Sensors["cInBG3915"]); + // Rad dreht (KR-M2204) + #fbSensorInput(stInSensorHW := "BG3916", + nInSensorNo := "cInBG3916", + stInOutSensor := "DB_Inputs".Sensors["cInBG3916"]); + // in Separator (ILS-CV M2209) + #fbSensorInput(stInSensorHW := "BG3920", + nInSensorNo := "cInBG3920", + stInOutSensor := "DB_Inputs".Sensors["cInBG3920"]); + // MT in Position (ILS-CV M2209) + #fbSensorInput(stInSensorHW := "BG3921", + nInSensorNo := "cInBG3921", + stInOutSensor := "DB_Inputs".Sensors["cInBG3921"]); + // Abfrage Mitnehmerfinger in Position (CV M2209) + #fbSensorInput(stInSensorHW := "BG3922", + nInSensorNo := "cInBG3922", + stInOutSensor := "DB_Inputs".Sensors["cInBG3922"]); + // in Separator 1 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3930", + nInSensorNo := "cInBG3930", + stInOutSensor := "DB_Inputs".Sensors["cInBG3930"]); + // in Separator 2 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3931", + nInSensorNo := "cInBG3931", + stInOutSensor := "DB_Inputs".Sensors["cInBG3931"]); + // in Separator 3 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3932", + nInSensorNo := "cInBG3932", + stInOutSensor := "DB_Inputs".Sensors["cInBG3932"]); + // in Separator 4 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3933", + nInSensorNo := "cInBG3933", + stInOutSensor := "DB_Inputs".Sensors["cInBG3933"]); + // in Separator 5 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3934", + nInSensorNo := "cInBG3934", + stInOutSensor := "DB_Inputs".Sensors["cInBG3934"]); + // in Separator 6 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3935", + nInSensorNo := "cInBG3935", + stInOutSensor := "DB_Inputs".Sensors["cInBG3935"]); + // in Separator 7 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3936", + nInSensorNo := "cInBG3936", + stInOutSensor := "DB_Inputs".Sensors["cInBG3936"]); + // in Separator 8 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3937", + nInSensorNo := "cInBG3937", + stInOutSensor := "DB_Inputs".Sensors["cInBG3937"]); + // in Separator 9 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3940", + nInSensorNo := "cInBG3940", + stInOutSensor := "DB_Inputs".Sensors["cInBG3940"]); + // in Separator 10 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3941", + nInSensorNo := "cInBG3941", + stInOutSensor := "DB_Inputs".Sensors["cInBG3941"]); + // in Separator 11 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3942", + nInSensorNo := "cInBG3942", + stInOutSensor := "DB_Inputs".Sensors["cInBG3942"]); + // in Separator 12 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3943", + nInSensorNo := "cInBG3943", + stInOutSensor := "DB_Inputs".Sensors["cInBG3943"]); + // in Separator 13 (Block 2.2.4) + #fbSensorInput(stInSensorHW := "BG3944", + nInSensorNo := "cInBG3944", + stInOutSensor := "DB_Inputs".Sensors["cInBG3944"]); + // in Separator 1 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG3960", + nInSensorNo := "cInBG3960", + stInOutSensor := "DB_Inputs".Sensors["cInBG3960"]); + // Staumelder, Einfahrt (ILS-CV M2305) + #fbSensorInput(stInSensorHW := "BG3961", + nInSensorNo := "cInBG3961", + stInOutSensor := "DB_Inputs".Sensors["cInBG3961"]); + // Stausensor (KR-M2301) + #fbSensorInput(stInSensorHW := "BG3962", + nInSensorNo := "cInBG3962", + stInOutSensor := "DB_Inputs".Sensors["cInBG3962"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2305) + #fbSensorInput(stInSensorHW := "BG3963", + nInSensorNo := "cInBG3963", + stInOutSensor := "DB_Inputs".Sensors["cInBG3963"]); + // in Separator (ILS-CV M2305) + #fbSensorInput(stInSensorHW := "BG3964", + nInSensorNo := "cInBG3964", + stInOutSensor := "DB_Inputs".Sensors["cInBG3964"]); + // in Separator (KR-M2301) + #fbSensorInput(stInSensorHW := "BG3965", + nInSensorNo := "cInBG3965", + stInOutSensor := "DB_Inputs".Sensors["cInBG3965"]); + // MT in Position (ILS-CV M2305) + #fbSensorInput(stInSensorHW := "BG3967", + nInSensorNo := "cInBG3967", + stInOutSensor := "DB_Inputs".Sensors["cInBG3967"]); + // in Separator 1 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG3990", + nInSensorNo := "cInBG3990", + stInOutSensor := "DB_Inputs".Sensors["cInBG3990"]); + // in Separator 2 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG3991", + nInSensorNo := "cInBG3991", + stInOutSensor := "DB_Inputs".Sensors["cInBG3991"]); + // in Separator 3 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG3992", + nInSensorNo := "cInBG3992", + stInOutSensor := "DB_Inputs".Sensors["cInBG3992"]); + // in Separator 4 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG3993", + nInSensorNo := "cInBG3993", + stInOutSensor := "DB_Inputs".Sensors["cInBG3993"]); + // in Separator 5 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG3994", + nInSensorNo := "cInBG3994", + stInOutSensor := "DB_Inputs".Sensors["cInBG3994"]); + // in Separator 6 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG3995", + nInSensorNo := "cInBG3995", + stInOutSensor := "DB_Inputs".Sensors["cInBG3995"]); + // in Separator 7 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG3996", + nInSensorNo := "cInBG3996", + stInOutSensor := "DB_Inputs".Sensors["cInBG3996"]); + // in Separator 8 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG3997", + nInSensorNo := "cInBG3997", + stInOutSensor := "DB_Inputs".Sensors["cInBG3997"]); + // in Separator 9 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4000", + nInSensorNo := "cInBG4000", + stInOutSensor := "DB_Inputs".Sensors["cInBG4000"]); + // in Separator 10 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4001", + nInSensorNo := "cInBG4001", + stInOutSensor := "DB_Inputs".Sensors["cInBG4001"]); + // in Separator 11 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4002", + nInSensorNo := "cInBG4002", + stInOutSensor := "DB_Inputs".Sensors["cInBG4002"]); + // in Separator 12 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4003", + nInSensorNo := "cInBG4003", + stInOutSensor := "DB_Inputs".Sensors["cInBG4003"]); + // in Separator 13 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4004", + nInSensorNo := "cInBG4004", + stInOutSensor := "DB_Inputs".Sensors["cInBG4004"]); + // in Separator 14 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4005", + nInSensorNo := "cInBG4005", + stInOutSensor := "DB_Inputs".Sensors["cInBG4005"]); + // in Separator 15 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4006", + nInSensorNo := "cInBG4006", + stInOutSensor := "DB_Inputs".Sensors["cInBG4006"]); + // in Separator 16 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4007", + nInSensorNo := "cInBG4007", + stInOutSensor := "DB_Inputs".Sensors["cInBG4007"]); + // in Separator 17 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4010", + nInSensorNo := "cInBG4010", + stInOutSensor := "DB_Inputs".Sensors["cInBG4010"]); + // in Separator 18 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4011", + nInSensorNo := "cInBG4011", + stInOutSensor := "DB_Inputs".Sensors["cInBG4011"]); + // In Separator 19 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4012", + nInSensorNo := "cInBG4012", + stInOutSensor := "DB_Inputs".Sensors["cInBG4012"]); + // in Separator 1 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4020", + nInSensorNo := "cInBG4020", + stInOutSensor := "DB_Inputs".Sensors["cInBG4020"]); + // Staumelder, Einfahrt (ILS-CV M2306) + #fbSensorInput(stInSensorHW := "BG4021", + nInSensorNo := "cInBG4021", + stInOutSensor := "DB_Inputs".Sensors["cInBG4021"]); + // Stausensor 1 (KR-M2301 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG4022", + nInSensorNo := "cInBG4022", + stInOutSensor := "DB_Inputs".Sensors["cInBG4022"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2206) + #fbSensorInput(stInSensorHW := "BG4023", + nInSensorNo := "cInBG4023", + stInOutSensor := "DB_Inputs".Sensors["cInBG4023"]); + // in Separator (ILS-CV M2206) + #fbSensorInput(stInSensorHW := "BG4024", + nInSensorNo := "cInBG4024", + stInOutSensor := "DB_Inputs".Sensors["cInBG4024"]); + // Stausensor 2 (KR-M2301) + #fbSensorInput(stInSensorHW := "BG4025", + nInSensorNo := "cInBG4025", + stInOutSensor := "DB_Inputs".Sensors["cInBG4025"]); + // Rad dreht (KR-M2301) + #fbSensorInput(stInSensorHW := "BG4026", + nInSensorNo := "cInBG4026", + stInOutSensor := "DB_Inputs".Sensors["cInBG4026"]); + // MT in Position (ILS-CV M2206) + #fbSensorInput(stInSensorHW := "BG4027", + nInSensorNo := "cInBG4027", + stInOutSensor := "DB_Inputs".Sensors["cInBG4027"]); + // in Separator 1 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4050", + nInSensorNo := "cInBG4050", + stInOutSensor := "DB_Inputs".Sensors["cInBG4050"]); + // in Separator 2 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4051", + nInSensorNo := "cInBG4051", + stInOutSensor := "DB_Inputs".Sensors["cInBG4051"]); + // in Separator 3 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4052", + nInSensorNo := "cInBG4052", + stInOutSensor := "DB_Inputs".Sensors["cInBG4052"]); + // in Separator 4 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4053", + nInSensorNo := "cInBG4053", + stInOutSensor := "DB_Inputs".Sensors["cInBG4053"]); + // in Separator 5 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4054", + nInSensorNo := "cInBG4054", + stInOutSensor := "DB_Inputs".Sensors["cInBG4054"]); + // in Separator 6 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4055", + nInSensorNo := "cInBG4055", + stInOutSensor := "DB_Inputs".Sensors["cInBG4055"]); + // in Separator 7 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4056", + nInSensorNo := "cInBG4056", + stInOutSensor := "DB_Inputs".Sensors["cInBG4056"]); + // in Separator 8 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4057", + nInSensorNo := "cInBG4057", + stInOutSensor := "DB_Inputs".Sensors["cInBG4057"]); + // in Separator 9 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4060", + nInSensorNo := "cInBG4060", + stInOutSensor := "DB_Inputs".Sensors["cInBG4060"]); + // in Separator 10 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4061", + nInSensorNo := "cInBG4061", + stInOutSensor := "DB_Inputs".Sensors["cInBG4061"]); + // in Separator 11 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4062", + nInSensorNo := "cInBG4062", + stInOutSensor := "DB_Inputs".Sensors["cInBG4062"]); + // in Separator 12 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4063", + nInSensorNo := "cInBG4063", + stInOutSensor := "DB_Inputs".Sensors["cInBG4063"]); + // in Separator 13 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4064", + nInSensorNo := "cInBG4064", + stInOutSensor := "DB_Inputs".Sensors["cInBG4064"]); + // in Separator 14 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4065", + nInSensorNo := "cInBG4065", + stInOutSensor := "DB_Inputs".Sensors["cInBG4065"]); + // in Separator 15 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4066", + nInSensorNo := "cInBG4066", + stInOutSensor := "DB_Inputs".Sensors["cInBG4066"]); + // in Separator 16 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4067", + nInSensorNo := "cInBG4067", + stInOutSensor := "DB_Inputs".Sensors["cInBG4067"]); + // in Separator 17 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4070", + nInSensorNo := "cInBG4070", + stInOutSensor := "DB_Inputs".Sensors["cInBG4070"]); + // in Separator 1 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4080", + nInSensorNo := "cInBG4080", + stInOutSensor := "DB_Inputs".Sensors["cInBG4080"]); + // Staumelder, Einfahrt (ILS-CV M2308 Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4081", + nInSensorNo := "cInBG4081", + stInOutSensor := "DB_Inputs".Sensors["cInBG4081"]); + // Stausensor 1 (KR-M2302 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG4082", + nInSensorNo := "cInBG4082", + stInOutSensor := "DB_Inputs".Sensors["cInBG4082"]); + // Abfrage Mitnehmerfinger in Position (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4083", + nInSensorNo := "cInBG4083", + stInOutSensor := "DB_Inputs".Sensors["cInBG4083"]); + // in Separator 2 (ILS-CV M2308 Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4084", + nInSensorNo := "cInBG4084", + stInOutSensor := "DB_Inputs".Sensors["cInBG4084"]); + // in Separator 3 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4085", + nInSensorNo := "cInBG4085", + stInOutSensor := "DB_Inputs".Sensors["cInBG4085"]); + // Stausensor 2 (M2302) + #fbSensorInput(stInSensorHW := "BG4086", + nInSensorNo := "cInBG4086", + stInOutSensor := "DB_Inputs".Sensors["cInBG4086"]); + // MT in Position (ILS-CV M2305) + #fbSensorInput(stInSensorHW := "BG4087", + nInSensorNo := "cInBG4087", + stInOutSensor := "DB_Inputs".Sensors["cInBG4087"]); + // Stausensor (ILS-CV 2309) + #fbSensorInput(stInSensorHW := "BG4090", + nInSensorNo := "cInBG4090", + stInOutSensor := "DB_Inputs".Sensors["cInBG4090"]); + // in Separator (ILS-CV 2309) + #fbSensorInput(stInSensorHW := "BG4091", + nInSensorNo := "cInBG4091", + stInOutSensor := "DB_Inputs".Sensors["cInBG4091"]); + // Stausensor (ILS-CV 2309) + #fbSensorInput(stInSensorHW := "BG4092", + nInSensorNo := "cInBG4092", + stInOutSensor := "DB_Inputs".Sensors["cInBG4092"]); + // Sensor Förderer voll (ILS-CV 2309) + #fbSensorInput(stInSensorHW := "BG4093", + nInSensorNo := "cInBG4093", + stInOutSensor := "DB_Inputs".Sensors["cInBG4093"]); + // Stausensor 3 (M2302) + #fbSensorInput(stInSensorHW := "BG4094", + nInSensorNo := "cInBG4094", + stInOutSensor := "DB_Inputs".Sensors["cInBG4094"]); + // in Separator 2 (ILS-CV M2309) + #fbSensorInput(stInSensorHW := "BG4095", + nInSensorNo := "cInBG4095", + stInOutSensor := "DB_Inputs".Sensors["cInBG4095"]); + // MT in Position (ILS-CV M2309) + #fbSensorInput(stInSensorHW := "BG4096", + nInSensorNo := "cInBG4096", + stInOutSensor := "DB_Inputs".Sensors["cInBG4096"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2309) + #fbSensorInput(stInSensorHW := "BG4097", + nInSensorNo := "cInBG4097", + stInOutSensor := "DB_Inputs".Sensors["cInBG4097"]); + // in Separator 1 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4110", + nInSensorNo := "cInBG4110", + stInOutSensor := "DB_Inputs".Sensors["cInBG4110"]); + // in Separator 2 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4111", + nInSensorNo := "cInBG4111", + stInOutSensor := "DB_Inputs".Sensors["cInBG4111"]); + // in Separator 3 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4112", + nInSensorNo := "cInBG4112", + stInOutSensor := "DB_Inputs".Sensors["cInBG4112"]); + // in Separator 4 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4113", + nInSensorNo := "cInBG4113", + stInOutSensor := "DB_Inputs".Sensors["cInBG4113"]); + // in Separator 5 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4114", + nInSensorNo := "cInBG4114", + stInOutSensor := "DB_Inputs".Sensors["cInBG4114"]); + // in Separator 6 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4115", + nInSensorNo := "cInBG4115", + stInOutSensor := "DB_Inputs".Sensors["cInBG4115"]); + // in Separator 7 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4116", + nInSensorNo := "cInBG4116", + stInOutSensor := "DB_Inputs".Sensors["cInBG4116"]); + // in Separator 8 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4117", + nInSensorNo := "cInBG4117", + stInOutSensor := "DB_Inputs".Sensors["cInBG4117"]); + // in Separator 9 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4120", + nInSensorNo := "cInBG4120", + stInOutSensor := "DB_Inputs".Sensors["cInBG4120"]); + // in Separator 10 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4121", + nInSensorNo := "cInBG4121", + stInOutSensor := "DB_Inputs".Sensors["cInBG4121"]); + // in Separator 11 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4122", + nInSensorNo := "cInBG4122", + stInOutSensor := "DB_Inputs".Sensors["cInBG4122"]); + // in Separator 12 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4123", + nInSensorNo := "cInBG4123", + stInOutSensor := "DB_Inputs".Sensors["cInBG4123"]); + // in Separator 13 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4124", + nInSensorNo := "cInBG4124", + stInOutSensor := "DB_Inputs".Sensors["cInBG4124"]); + // in Separator 14 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4125", + nInSensorNo := "cInBG4125", + stInOutSensor := "DB_Inputs".Sensors["cInBG4125"]); + // in Separator 15 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4126", + nInSensorNo := "cInBG4126", + stInOutSensor := "DB_Inputs".Sensors["cInBG4126"]); + // in Separator 16 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4127", + nInSensorNo := "cInBG4127", + stInOutSensor := "DB_Inputs".Sensors["cInBG4127"]); + // in Separator 17 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4130", + nInSensorNo := "cInBG4130", + stInOutSensor := "DB_Inputs".Sensors["cInBG4130"]); + // in Separator 18 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4131", + nInSensorNo := "cInBG4131", + stInOutSensor := "DB_Inputs".Sensors["cInBG4131"]); + // in Separator 19 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4132", + nInSensorNo := "cInBG4132", + stInOutSensor := "DB_Inputs".Sensors["cInBG4132"]); + // in Separator 20 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4133", + nInSensorNo := "cInBG4133", + stInOutSensor := "DB_Inputs".Sensors["cInBG4133"]); + // in Separator 21 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4134", + nInSensorNo := "cInBG4134", + stInOutSensor := "DB_Inputs".Sensors["cInBG4134"]); + // in Separator 1 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4140", + nInSensorNo := "cInBG4140", + stInOutSensor := "DB_Inputs".Sensors["cInBG4140"]); + // Staumelder, Einfahrt (ILS-CV M2308) + #fbSensorInput(stInSensorHW := "BG4141", + nInSensorNo := "cInBG4141", + stInOutSensor := "DB_Inputs".Sensors["cInBG4141"]); + // Stausensor 1 (KR-M2302 nach BT-Beladung) + #fbSensorInput(stInSensorHW := "BG4142", + nInSensorNo := "cInBG4142", + stInOutSensor := "DB_Inputs".Sensors["cInBG4142"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2308) + #fbSensorInput(stInSensorHW := "BG4143", + nInSensorNo := "cInBG4143", + stInOutSensor := "DB_Inputs".Sensors["cInBG4143"]); + // in Separator (ILS-CV M2308) + #fbSensorInput(stInSensorHW := "BG4144", + nInSensorNo := "cInBG4144", + stInOutSensor := "DB_Inputs".Sensors["cInBG4144"]); + // in Separator 3 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4145", + nInSensorNo := "cInBG4145", + stInOutSensor := "DB_Inputs".Sensors["cInBG4145"]); + // MT in Position (ILS-CV M2308) + #fbSensorInput(stInSensorHW := "BG4147", + nInSensorNo := "cInBG4147", + stInOutSensor := "DB_Inputs".Sensors["cInBG4147"]); + // Rad dreht (KR-M2302) + #fbSensorInput(stInSensorHW := "BG4150", + nInSensorNo := "cInBG4150", + stInOutSensor := "DB_Inputs".Sensors["cInBG4150"]); + // Staumelder, Einfahrt (ILS-CV M2302 Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4152", + nInSensorNo := "cInBG4152", + stInOutSensor := "DB_Inputs".Sensors["cInBG4152"]); + // in Separator 1 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4170", + nInSensorNo := "cInBG4170", + stInOutSensor := "DB_Inputs".Sensors["cInBG4170"]); + // in Separator 2 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4171", + nInSensorNo := "cInBG4171", + stInOutSensor := "DB_Inputs".Sensors["cInBG4171"]); + // in Separator 3 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4172", + nInSensorNo := "cInBG4172", + stInOutSensor := "DB_Inputs".Sensors["cInBG4172"]); + // in Separator 4 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4173", + nInSensorNo := "cInBG4173", + stInOutSensor := "DB_Inputs".Sensors["cInBG4173"]); + // in Separator 5 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4174", + nInSensorNo := "cInBG4174", + stInOutSensor := "DB_Inputs".Sensors["cInBG4174"]); + // in Separator 6 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4175", + nInSensorNo := "cInBG4175", + stInOutSensor := "DB_Inputs".Sensors["cInBG4175"]); + // in Separator 7 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4176", + nInSensorNo := "cInBG4176", + stInOutSensor := "DB_Inputs".Sensors["cInBG4176"]); + // in Separator 8 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4177", + nInSensorNo := "cInBG4177", + stInOutSensor := "DB_Inputs".Sensors["cInBG4177"]); + // in Separator 9 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4180", + nInSensorNo := "cInBG4180", + stInOutSensor := "DB_Inputs".Sensors["cInBG4180"]); + // in Separator 10 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4181", + nInSensorNo := "cInBG4181", + stInOutSensor := "DB_Inputs".Sensors["cInBG4181"]); + // in Separator 11 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4182", + nInSensorNo := "cInBG4182", + stInOutSensor := "DB_Inputs".Sensors["cInBG4182"]); + // in Separator 12 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4183", + nInSensorNo := "cInBG4183", + stInOutSensor := "DB_Inputs".Sensors["cInBG4183"]); + // in Separator 13 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4184", + nInSensorNo := "cInBG4184", + stInOutSensor := "DB_Inputs".Sensors["cInBG4184"]); + // in Separator 14 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4185", + nInSensorNo := "cInBG4185", + stInOutSensor := "DB_Inputs".Sensors["cInBG4185"]); + // in Separator 15 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4186", + nInSensorNo := "cInBG4186", + stInOutSensor := "DB_Inputs".Sensors["cInBG4186"]); + // in Separator 2 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4200", + nInSensorNo := "cInBG4200", + stInOutSensor := "DB_Inputs".Sensors["cInBG4200"]); + // Pin Abfrage (KR-M2303 ) Block 2.3.1 + #fbSensorInput(stInSensorHW := "BG4201", + nInSensorNo := "cInBG4201", + stInOutSensor := "DB_Inputs".Sensors["cInBG4201"]); + // Prüfung MT Pos.1 (KR-K2303 Einfahrt Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4202", + nInSensorNo := "cInBG4202", + stInOutSensor := "DB_Inputs".Sensors["cInBG4202"]); + // Stausensor (KR-M2303 ) Block 2.3.1 + #fbSensorInput(stInSensorHW := "BG4203", + nInSensorNo := "cInBG4203", + stInOutSensor := "DB_Inputs".Sensors["cInBG4203"]); + // in Separator (ILS-CV 2305) + #fbSensorInput(stInSensorHW := "BG4204", + nInSensorNo := "cInBG4204", + stInOutSensor := "DB_Inputs".Sensors["cInBG4204"]); + // Stausensor (ILS-CV 2305) + #fbSensorInput(stInSensorHW := "BG4205", + nInSensorNo := "cInBG4205", + stInOutSensor := "DB_Inputs".Sensors["cInBG4205"]); + // Sensor Förderer voll (ILS-CV 2305) + #fbSensorInput(stInSensorHW := "BG4206", + nInSensorNo := "cInBG4206", + stInOutSensor := "DB_Inputs".Sensors["cInBG4206"]); + // Prüfung MT Pos.2 (KR-K2303 Einfahrt Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4207", + nInSensorNo := "cInBG4207", + stInOutSensor := "DB_Inputs".Sensors["cInBG4207"]); + // Prüfung MT Pos.3 (KR-K2303 Einfahrt Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4210", + nInSensorNo := "cInBG4210", + stInOutSensor := "DB_Inputs".Sensors["cInBG4210"]); + // Prüfung MT Pos.4 (KR-K2303 Einfahrt Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4211", + nInSensorNo := "cInBG4211", + stInOutSensor := "DB_Inputs".Sensors["cInBG4211"]); + // Prüfung MT Pos.5 (KR-K2303 Einfahrt Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4212", + nInSensorNo := "cInBG4212", + stInOutSensor := "DB_Inputs".Sensors["cInBG4212"]); + // Stausensor Str.1 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4230", + nInSensorNo := "cInBG4230", + stInOutSensor := "DB_Inputs".Sensors["cInBG4230"]); + // Stausensor Str.2 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4231", + nInSensorNo := "cInBG4231", + stInOutSensor := "DB_Inputs".Sensors["cInBG4231"]); + // Stausensor Str.3 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4232", + nInSensorNo := "cInBG4232", + stInOutSensor := "DB_Inputs".Sensors["cInBG4232"]); + // Stausensor Str.4 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4233", + nInSensorNo := "cInBG4233", + stInOutSensor := "DB_Inputs".Sensors["cInBG4233"]); + // Stausensor Str.5 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4234", + nInSensorNo := "cInBG4234", + stInOutSensor := "DB_Inputs".Sensors["cInBG4234"]); + // Stausensor Str.6 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4235", + nInSensorNo := "cInBG4235", + stInOutSensor := "DB_Inputs".Sensors["cInBG4235"]); + // Stausensor Str.7 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4236", + nInSensorNo := "cInBG4236", + stInOutSensor := "DB_Inputs".Sensors["cInBG4236"]); + // Stausensor Str.8 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4237", + nInSensorNo := "cInBG4237", + stInOutSensor := "DB_Inputs".Sensors["cInBG4237"]); + // Stausensor Str.9 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4240", + nInSensorNo := "cInBG4240", + stInOutSensor := "DB_Inputs".Sensors["cInBG4240"]); + // Stausensor Str.10 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4241", + nInSensorNo := "cInBG4241", + stInOutSensor := "DB_Inputs".Sensors["cInBG4241"]); + // Stausensor Str.11 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4242", + nInSensorNo := "cInBG4242", + stInOutSensor := "DB_Inputs".Sensors["cInBG4242"]); + // Stausensor Str.12 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4243", + nInSensorNo := "cInBG4243", + stInOutSensor := "DB_Inputs".Sensors["cInBG4243"]); + // Stausensor Str.13 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4244", + nInSensorNo := "cInBG4244", + stInOutSensor := "DB_Inputs".Sensors["cInBG4244"]); + // Stausensor Str.14 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4245", + nInSensorNo := "cInBG4245", + stInOutSensor := "DB_Inputs".Sensors["cInBG4245"]); + // Stausensor Str.15 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4246", + nInSensorNo := "cInBG4246", + stInOutSensor := "DB_Inputs".Sensors["cInBG4246"]); + // Stausensor Str.16 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4247", + nInSensorNo := "cInBG4247", + stInOutSensor := "DB_Inputs".Sensors["cInBG4247"]); + // Stausensor Str.17 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4250", + nInSensorNo := "cInBG4250", + stInOutSensor := "DB_Inputs".Sensors["cInBG4250"]); + // Stausensor Str.18 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4251", + nInSensorNo := "cInBG4251", + stInOutSensor := "DB_Inputs".Sensors["cInBG4251"]); + // Stausensor Str.19 (Block 2.3.1) + #fbSensorInput(stInSensorHW := "BG4252", + nInSensorNo := "cInBG4252", + stInOutSensor := "DB_Inputs".Sensors["cInBG4252"]); + // in Separator 2 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4260", + nInSensorNo := "cInBG4260", + stInOutSensor := "DB_Inputs".Sensors["cInBG4260"]); + // Pin Abfrage (KR-M2303 ) Block 2.3.2 + #fbSensorInput(stInSensorHW := "BG4261", + nInSensorNo := "cInBG4261", + stInOutSensor := "DB_Inputs".Sensors["cInBG4261"]); + // Prüfung MT Pos.1 (KR-K2303 Einfahrt Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4262", + nInSensorNo := "cInBG4262", + stInOutSensor := "DB_Inputs".Sensors["cInBG4262"]); + // Stausensor (KR-M2303) + #fbSensorInput(stInSensorHW := "BG4263", + nInSensorNo := "cInBG4263", + stInOutSensor := "DB_Inputs".Sensors["cInBG4263"]); + // in Separator (ILS-CV 2306) + #fbSensorInput(stInSensorHW := "BG4264", + nInSensorNo := "cInBG4264", + stInOutSensor := "DB_Inputs".Sensors["cInBG4264"]); + // Stausensor (ILS-CV 2306) + #fbSensorInput(stInSensorHW := "BG4265", + nInSensorNo := "cInBG4265", + stInOutSensor := "DB_Inputs".Sensors["cInBG4265"]); + // Sensor Förderer voll (ILS-CV 2306) + #fbSensorInput(stInSensorHW := "BG4266", + nInSensorNo := "cInBG4266", + stInOutSensor := "DB_Inputs".Sensors["cInBG4266"]); + // Prüfung MT Pos.2 (KR-K2303 Einfahrt Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4267", + nInSensorNo := "cInBG4267", + stInOutSensor := "DB_Inputs".Sensors["cInBG4267"]); + // Prüfung MT Pos.3 (KR-K2303 Einfahrt Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4270", + nInSensorNo := "cInBG4270", + stInOutSensor := "DB_Inputs".Sensors["cInBG4270"]); + // Prüfung MT Pos.4 (KR-K2303 Einfahrt Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4271", + nInSensorNo := "cInBG4271", + stInOutSensor := "DB_Inputs".Sensors["cInBG4271"]); + // Prüfung MT Pos.5 (KR-K2303 Einfahrt Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4272", + nInSensorNo := "cInBG4272", + stInOutSensor := "DB_Inputs".Sensors["cInBG4272"]); + // Stausensor MT vor Pinband (KR-K2303) Block 2.3.2 + #fbSensorInput(stInSensorHW := "BG4273", + nInSensorNo := "cInBG4273", + stInOutSensor := "DB_Inputs".Sensors["cInBG4273"]); + // Stausensor Str.1 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4290", + nInSensorNo := "cInBG4290", + stInOutSensor := "DB_Inputs".Sensors["cInBG4290"]); + // Stausensor Str.2 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4291", + nInSensorNo := "cInBG4291", + stInOutSensor := "DB_Inputs".Sensors["cInBG4291"]); + // Stausensor Str.3 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4292", + nInSensorNo := "cInBG4292", + stInOutSensor := "DB_Inputs".Sensors["cInBG4292"]); + // Stausensor Str.4 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4293", + nInSensorNo := "cInBG4293", + stInOutSensor := "DB_Inputs".Sensors["cInBG4293"]); + // Stausensor Str.5 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4294", + nInSensorNo := "cInBG4294", + stInOutSensor := "DB_Inputs".Sensors["cInBG4294"]); + // Stausensor Str.6 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4295", + nInSensorNo := "cInBG4295", + stInOutSensor := "DB_Inputs".Sensors["cInBG4295"]); + // Stausensor Str.7 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4296", + nInSensorNo := "cInBG4296", + stInOutSensor := "DB_Inputs".Sensors["cInBG4296"]); + // Stausensor Str.8 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4297", + nInSensorNo := "cInBG4297", + stInOutSensor := "DB_Inputs".Sensors["cInBG4297"]); + // Stausensor Str.9 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4300", + nInSensorNo := "cInBG4300", + stInOutSensor := "DB_Inputs".Sensors["cInBG4300"]); + // Stausensor Str.10 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4301", + nInSensorNo := "cInBG4301", + stInOutSensor := "DB_Inputs".Sensors["cInBG4301"]); + // Stausensor Str.11 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4302", + nInSensorNo := "cInBG4302", + stInOutSensor := "DB_Inputs".Sensors["cInBG4302"]); + // Stausensor Str.12 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4303", + nInSensorNo := "cInBG4303", + stInOutSensor := "DB_Inputs".Sensors["cInBG4303"]); + // Stausensor Str.13 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4304", + nInSensorNo := "cInBG4304", + stInOutSensor := "DB_Inputs".Sensors["cInBG4304"]); + // Stausensor Str.14 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4305", + nInSensorNo := "cInBG4305", + stInOutSensor := "DB_Inputs".Sensors["cInBG4305"]); + // Stausensor Str.15 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4306", + nInSensorNo := "cInBG4306", + stInOutSensor := "DB_Inputs".Sensors["cInBG4306"]); + // Stausensor Str.16 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4307", + nInSensorNo := "cInBG4307", + stInOutSensor := "DB_Inputs".Sensors["cInBG4307"]); + // Stausensor Str.17 (Block 2.3.2) + #fbSensorInput(stInSensorHW := "BG4310", + nInSensorNo := "cInBG4310", + stInOutSensor := "DB_Inputs".Sensors["cInBG4310"]); + // in Separator 2 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4320", + nInSensorNo := "cInBG4320", + stInOutSensor := "DB_Inputs".Sensors["cInBG4320"]); + // Pin Abfrage (KR-M2304) Block 2.3.3 + #fbSensorInput(stInSensorHW := "BG4321", + nInSensorNo := "cInBG4321", + stInOutSensor := "DB_Inputs".Sensors["cInBG4321"]); + // Prüfung MT Pos.1 (KR-K2304 Einfahrt Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4322", + nInSensorNo := "cInBG4322", + stInOutSensor := "DB_Inputs".Sensors["cInBG4322"]); + // Stausensor (KR-M2304) + #fbSensorInput(stInSensorHW := "BG4323", + nInSensorNo := "cInBG4323", + stInOutSensor := "DB_Inputs".Sensors["cInBG4323"]); + // in Separator 1 (ILS-CV 2307) + #fbSensorInput(stInSensorHW := "BG4324", + nInSensorNo := "cInBG4324", + stInOutSensor := "DB_Inputs".Sensors["cInBG4324"]); + // Stausensor Str.1 (KR-K2307 vor BT-Beladung) + #fbSensorInput(stInSensorHW := "BG4325", + nInSensorNo := "cInBG4325", + stInOutSensor := "DB_Inputs".Sensors["cInBG4325"]); + // Sensor Förderer voll (ILS-CV 2307) + #fbSensorInput(stInSensorHW := "BG4326", + nInSensorNo := "cInBG4326", + stInOutSensor := "DB_Inputs".Sensors["cInBG4326"]); + // Prüfung MT Pos.2 (KR-K2304 Einfahrt Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4327", + nInSensorNo := "cInBG4327", + stInOutSensor := "DB_Inputs".Sensors["cInBG4327"]); + // Prüfung MT Pos.3 (KR-K2304 Einfahrt Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4330", + nInSensorNo := "cInBG4330", + stInOutSensor := "DB_Inputs".Sensors["cInBG4330"]); + // Prüfung MT Pos.4 (KR-K2304 Einfahrt Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4331", + nInSensorNo := "cInBG4331", + stInOutSensor := "DB_Inputs".Sensors["cInBG4331"]); + // Prüfung MT Pos.5 (KR-K2304 Einfahrt Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4332", + nInSensorNo := "cInBG4332", + stInOutSensor := "DB_Inputs".Sensors["cInBG4332"]); + // Prüfung MT Pos.6 (KR-K2304 Einfahrt Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4333", + nInSensorNo := "cInBG4333", + stInOutSensor := "DB_Inputs".Sensors["cInBG4333"]); + // in Separator 3 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4334", + nInSensorNo := "cInBG4334", + stInOutSensor := "DB_Inputs".Sensors["cInBG4334"]); + // Stausensor 1 (M2309) + #fbSensorInput(stInSensorHW := "BG4335", + nInSensorNo := "cInBG4335", + stInOutSensor := "DB_Inputs".Sensors["cInBG4335"]); + // Stausensor 1 (M2309) + #fbSensorInput(stInSensorHW := "BG4336", + nInSensorNo := "cInBG4336", + stInOutSensor := "DB_Inputs".Sensors["cInBG4336"]); + // in Separator 1 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4337", + nInSensorNo := "cInBG4337", + stInOutSensor := "DB_Inputs".Sensors["cInBG4337"]); + // Stausensor Str.1 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4350", + nInSensorNo := "cInBG4350", + stInOutSensor := "DB_Inputs".Sensors["cInBG4350"]); + // Stausensor Str.2 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4351", + nInSensorNo := "cInBG4351", + stInOutSensor := "DB_Inputs".Sensors["cInBG4351"]); + // Stausensor Str.3 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4352", + nInSensorNo := "cInBG4352", + stInOutSensor := "DB_Inputs".Sensors["cInBG4352"]); + // Stausensor Str.4 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4353", + nInSensorNo := "cInBG4353", + stInOutSensor := "DB_Inputs".Sensors["cInBG4353"]); + // Stausensor Str.5 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4354", + nInSensorNo := "cInBG4354", + stInOutSensor := "DB_Inputs".Sensors["cInBG4354"]); + // Stausensor Str.6 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4355", + nInSensorNo := "cInBG4355", + stInOutSensor := "DB_Inputs".Sensors["cInBG4355"]); + // Stausensor Str.7 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4356", + nInSensorNo := "cInBG4356", + stInOutSensor := "DB_Inputs".Sensors["cInBG4356"]); + // Stausensor Str.8 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4357", + nInSensorNo := "cInBG4357", + stInOutSensor := "DB_Inputs".Sensors["cInBG4357"]); + // Stausensor Str.9 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4360", + nInSensorNo := "cInBG4360", + stInOutSensor := "DB_Inputs".Sensors["cInBG4360"]); + // Stausensor Str.10 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4361", + nInSensorNo := "cInBG4361", + stInOutSensor := "DB_Inputs".Sensors["cInBG4361"]); + // Stausensor Str.11 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4362", + nInSensorNo := "cInBG4362", + stInOutSensor := "DB_Inputs".Sensors["cInBG4362"]); + // Stausensor Str.12 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4363", + nInSensorNo := "cInBG4363", + stInOutSensor := "DB_Inputs".Sensors["cInBG4363"]); + // Stausensor Str.13 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4364", + nInSensorNo := "cInBG4364", + stInOutSensor := "DB_Inputs".Sensors["cInBG4364"]); + // Stausensor Str.14 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4365", + nInSensorNo := "cInBG4365", + stInOutSensor := "DB_Inputs".Sensors["cInBG4365"]); + // Stausensor Str.15 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4366", + nInSensorNo := "cInBG4366", + stInOutSensor := "DB_Inputs".Sensors["cInBG4366"]); + // Stausensor Str.16 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4367", + nInSensorNo := "cInBG4367", + stInOutSensor := "DB_Inputs".Sensors["cInBG4367"]); + // Stausensor Str.17 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4370", + nInSensorNo := "cInBG4370", + stInOutSensor := "DB_Inputs".Sensors["cInBG4370"]); + // Stausensor Str.18 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4371", + nInSensorNo := "cInBG4371", + stInOutSensor := "DB_Inputs".Sensors["cInBG4371"]); + // Stausensor Str.19 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4372", + nInSensorNo := "cInBG4372", + stInOutSensor := "DB_Inputs".Sensors["cInBG4372"]); + // Stausensor Str.20 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4373", + nInSensorNo := "cInBG4373", + stInOutSensor := "DB_Inputs".Sensors["cInBG4373"]); + // Stausensor Str.21 (Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4374", + nInSensorNo := "cInBG4374", + stInOutSensor := "DB_Inputs".Sensors["cInBG4374"]); + // Stausensor MT vor Pinband (KR-K2304) Block 2.3.3) + #fbSensorInput(stInSensorHW := "BG4375", + nInSensorNo := "cInBG4375", + stInOutSensor := "DB_Inputs".Sensors["cInBG4375"]); + // in Separator 2 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4380", + nInSensorNo := "cInBG4380", + stInOutSensor := "DB_Inputs".Sensors["cInBG4380"]); + // Pin Abfrage (KR-M2304) Block 2.3.4 + #fbSensorInput(stInSensorHW := "BG4381", + nInSensorNo := "cInBG4381", + stInOutSensor := "DB_Inputs".Sensors["cInBG4381"]); + // Prüfung MT Pos.1 (KR-K2304 Einfahrt Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4382", + nInSensorNo := "cInBG4382", + stInOutSensor := "DB_Inputs".Sensors["cInBG4382"]); + // Stausensor (KR-M2304) + #fbSensorInput(stInSensorHW := "BG4383", + nInSensorNo := "cInBG4383", + stInOutSensor := "DB_Inputs".Sensors["cInBG4383"]); + // in Separator 1 (ILS-CV M2308) + #fbSensorInput(stInSensorHW := "BG4384", + nInSensorNo := "cInBG4384", + stInOutSensor := "DB_Inputs".Sensors["cInBG4384"]); + // Stausensor (ILS-CV M2308) + #fbSensorInput(stInSensorHW := "BG4385", + nInSensorNo := "cInBG4385", + stInOutSensor := "DB_Inputs".Sensors["cInBG4385"]); + // Sensor Förderer voll (ILS-CV 2308) + #fbSensorInput(stInSensorHW := "BG4386", + nInSensorNo := "cInBG4386", + stInOutSensor := "DB_Inputs".Sensors["cInBG4386"]); + // Prüfung MT Pos.2 (KR-K2304 Einfahrt Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4387", + nInSensorNo := "cInBG4387", + stInOutSensor := "DB_Inputs".Sensors["cInBG4387"]); + // Prüfung MT Pos.3 (KR-K2304 Einfahrt Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4390", + nInSensorNo := "cInBG4390", + stInOutSensor := "DB_Inputs".Sensors["cInBG4390"]); + // Prüfung MT Pos.4 (KR-K2304 Einfahrt Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4391", + nInSensorNo := "cInBG4391", + stInOutSensor := "DB_Inputs".Sensors["cInBG4391"]); + // Stausensor 3 (M2302) + #fbSensorInput(stInSensorHW := "BG4392", + nInSensorNo := "cInBG4392", + stInOutSensor := "DB_Inputs".Sensors["cInBG4392"]); + // in Separator 1 (KR-K2210 Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4395", + nInSensorNo := "cInBG4395", + stInOutSensor := "DB_Inputs".Sensors["cInBG4395"]); + // Rad dreht (KR-K2210) + #fbSensorInput(stInSensorHW := "BG4396", + nInSensorNo := "cInBG4396", + stInOutSensor := "DB_Inputs".Sensors["cInBG4396"]); + // Stausensor Str.1 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4410", + nInSensorNo := "cInBG4410", + stInOutSensor := "DB_Inputs".Sensors["cInBG4410"]); + // Stausensor Str.2 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4411", + nInSensorNo := "cInBG4411", + stInOutSensor := "DB_Inputs".Sensors["cInBG4411"]); + // Stausensor Str.3 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4412", + nInSensorNo := "cInBG4412", + stInOutSensor := "DB_Inputs".Sensors["cInBG4412"]); + // Stausensor Str.4 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4413", + nInSensorNo := "cInBG4413", + stInOutSensor := "DB_Inputs".Sensors["cInBG4413"]); + // Stausensor Str.5 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4414", + nInSensorNo := "cInBG4414", + stInOutSensor := "DB_Inputs".Sensors["cInBG4414"]); + // Stausensor Str.6 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4415", + nInSensorNo := "cInBG4415", + stInOutSensor := "DB_Inputs".Sensors["cInBG4415"]); + // Stausensor Str.7 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4416", + nInSensorNo := "cInBG4416", + stInOutSensor := "DB_Inputs".Sensors["cInBG4416"]); + // Stausensor Str.8 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4417", + nInSensorNo := "cInBG4417", + stInOutSensor := "DB_Inputs".Sensors["cInBG4417"]); + // Stausensor Str.9 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4420", + nInSensorNo := "cInBG4420", + stInOutSensor := "DB_Inputs".Sensors["cInBG4420"]); + // Stausensor Str.10 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4421", + nInSensorNo := "cInBG4421", + stInOutSensor := "DB_Inputs".Sensors["cInBG4421"]); + // Stausensor Str.11 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4422", + nInSensorNo := "cInBG4422", + stInOutSensor := "DB_Inputs".Sensors["cInBG4422"]); + // Stausensor Str.12 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4423", + nInSensorNo := "cInBG4423", + stInOutSensor := "DB_Inputs".Sensors["cInBG4423"]); + // Stausensor Str.13 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4424", + nInSensorNo := "cInBG4424", + stInOutSensor := "DB_Inputs".Sensors["cInBG4424"]); + // Stausensor Str.14 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4425", + nInSensorNo := "cInBG4425", + stInOutSensor := "DB_Inputs".Sensors["cInBG4425"]); + // Stausensor Str.15 (Block 2.3.4) + #fbSensorInput(stInSensorHW := "BG4426", + nInSensorNo := "cInBG4426", + stInOutSensor := "DB_Inputs".Sensors["cInBG4426"]); + // in Separator 1 (ILS-CV 2111) + #fbSensorInput(stInSensorHW := "BG4440", + nInSensorNo := "cInBG4440", + stInOutSensor := "DB_Inputs".Sensors["cInBG4440"]); + // Stausensor (ILS-CV 2111) + #fbSensorInput(stInSensorHW := "BG4441", + nInSensorNo := "cInBG4441", + stInOutSensor := "DB_Inputs".Sensors["cInBG4441"]); + // Sensor Förderer voll (ILS-CV 2111) + #fbSensorInput(stInSensorHW := "BG4442", + nInSensorNo := "cInBG4442", + stInOutSensor := "DB_Inputs".Sensors["cInBG4442"]); + // Stausensor 2 ((KR-K2110) + #fbSensorInput(stInSensorHW := "BG4443", + nInSensorNo := "cInBG4443", + stInOutSensor := "DB_Inputs".Sensors["cInBG4443"]); + // in Separator 3 (KR-K2110) + #fbSensorInput(stInSensorHW := "BG4444", + nInSensorNo := "cInBG4444", + stInOutSensor := "DB_Inputs".Sensors["cInBG4444"]); + // in Separator (ILS-CV M2111) + #fbSensorInput(stInSensorHW := "BG4450", + nInSensorNo := "cInBG4450", + stInOutSensor := "DB_Inputs".Sensors["cInBG4450"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M2111) + #fbSensorInput(stInSensorHW := "BG4451", + nInSensorNo := "cInBG4451", + stInOutSensor := "DB_Inputs".Sensors["cInBG4451"]); + // MT in Position (ILS-CV M2111) + #fbSensorInput(stInSensorHW := "BG4452", + nInSensorNo := "cInBG4452", + stInOutSensor := "DB_Inputs".Sensors["cInBG4452"]); + // in Separator 1 (KR-M2110) + #fbSensorInput(stInSensorHW := "BG4500", + nInSensorNo := "cInBG4500", + stInOutSensor := "DB_Inputs".Sensors["cInBG4500"]); + // in Separator 2 (KR-M2110) + #fbSensorInput(stInSensorHW := "BG4503", + nInSensorNo := "cInBG4503", + stInOutSensor := "DB_Inputs".Sensors["cInBG4503"]); + // Stausensor 1 (KR-M2110) + #fbSensorInput(stInSensorHW := "BG4504", + nInSensorNo := "cInBG4504", + stInOutSensor := "DB_Inputs".Sensors["cInBG4504"]); + // Rad dreht (KR-M2110) + #fbSensorInput(stInSensorHW := "BG4505", + nInSensorNo := "cInBG4505", + stInOutSensor := "DB_Inputs".Sensors["cInBG4505"]); + // Stausensor 3 (KR-K2210) + #fbSensorInput(stInSensorHW := "BG4507", + nInSensorNo := "cInBG4507", + stInOutSensor := "DB_Inputs".Sensors["cInBG4507"]); + // in Separator 1 (KR-M2110) + #fbSensorInput(stInSensorHW := "BG4560", + nInSensorNo := "cInBG4560", + stInOutSensor := "DB_Inputs".Sensors["cInBG4560"]); + // Teil auf MT (Sep 3MB4560) + #fbSensorInput(stInSensorHW := "BG4561", + nInSensorNo := "cInBG4561", + stInOutSensor := "DB_Inputs".Sensors["cInBG4561"]); + // in Separator 1 (ILS-CV M4101) + #fbSensorInput(stInSensorHW := "BG4562", + nInSensorNo := "cInBG4562", + stInOutSensor := "DB_Inputs".Sensors["cInBG4562"]); + // Stausensor 1 (ILS-CV M4201) + #fbSensorInput(stInSensorHW := "BG4563", + nInSensorNo := "cInBG4563", + stInOutSensor := "DB_Inputs".Sensors["cInBG4563"]); + // Stausensor 1 (ILS-CV M4101) + #fbSensorInput(stInSensorHW := "BG4564", + nInSensorNo := "cInBG4564", + stInOutSensor := "DB_Inputs".Sensors["cInBG4564"]); + // Sensor Förderer voll (ILS-CV M4101) + #fbSensorInput(stInSensorHW := "BG4565", + nInSensorNo := "cInBG4565", + stInOutSensor := "DB_Inputs".Sensors["cInBG4565"]); + // in Separator 2 (ILS-CV M4101) + #fbSensorInput(stInSensorHW := "BG4566", + nInSensorNo := "cInBG4566", + stInOutSensor := "DB_Inputs".Sensors["cInBG4566"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4101) + #fbSensorInput(stInSensorHW := "BG4567", + nInSensorNo := "cInBG4567", + stInOutSensor := "DB_Inputs".Sensors["cInBG4567"]); + // MT in Position (ILS-CV M4101) + #fbSensorInput(stInSensorHW := "BG4570", + nInSensorNo := "cInBG4570", + stInOutSensor := "DB_Inputs".Sensors["cInBG4570"]); + // MT in Position (ILS-CV M4201) + #fbSensorInput(stInSensorHW := "BG4571", + nInSensorNo := "cInBG4571", + stInOutSensor := "DB_Inputs".Sensors["cInBG4571"]); + // in Separator 1 (ILS-CV M4201) + #fbSensorInput(stInSensorHW := "BG4572", + nInSensorNo := "cInBG4572", + stInOutSensor := "DB_Inputs".Sensors["cInBG4572"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4201) + #fbSensorInput(stInSensorHW := "BG4573", + nInSensorNo := "cInBG4573", + stInOutSensor := "DB_Inputs".Sensors["cInBG4573"]); + // Sensor Förderer voll (ILS-CV M4201) + #fbSensorInput(stInSensorHW := "BG4574", + nInSensorNo := "cInBG4574", + stInOutSensor := "DB_Inputs".Sensors["cInBG4574"]); + // in Separator 2 (ILS-CV M4201) + #fbSensorInput(stInSensorHW := "BG4575", + nInSensorNo := "cInBG4575", + stInOutSensor := "DB_Inputs".Sensors["cInBG4575"]); + // in Separator (ILS-KR M2110) + #fbSensorInput(stInSensorHW := "BG4576", + nInSensorNo := "cInBG4576", + stInOutSensor := "DB_Inputs".Sensors["cInBG4576"]); + // Stausensor 3 (KR-M2110) + #fbSensorInput(stInSensorHW := "BG4577", + nInSensorNo := "cInBG4577", + stInOutSensor := "DB_Inputs".Sensors["cInBG4577"]); + // IF BST "No fire alarm" + #fbSensorInput(stInSensorHW := "DI4610", + nInSensorNo := "cInDI4610", + stInOutSensor := "DB_Inputs".Sensors["cInDI4610"]); + // IF BST "Non fault" + #fbSensorInput(stInSensorHW := "DI4611", + nInSensorNo := "cInDI4611", + stInOutSensor := "DB_Inputs".Sensors["cInDI4611"]); + // IF BST "FPC opened" + #fbSensorInput(stInSensorHW := "DI4612", + nInSensorNo := "cInDI4612", + stInOutSensor := "DB_Inputs".Sensors["cInDI4612"]); + // Stausensor (ILS-CV M4102) + #fbSensorInput(stInSensorHW := "BG4621", + nInSensorNo := "cInBG4621", + stInOutSensor := "DB_Inputs".Sensors["cInBG4621"]); + // Sensor Förderer voll (ILS-CV M4102) + #fbSensorInput(stInSensorHW := "BG4622", + nInSensorNo := "cInBG4622", + stInOutSensor := "DB_Inputs".Sensors["cInBG4622"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4102) + #fbSensorInput(stInSensorHW := "BG4623", + nInSensorNo := "cInBG4623", + stInOutSensor := "DB_Inputs".Sensors["cInBG4623"]); + // in Separator 1 (ILS-CV M4102) + #fbSensorInput(stInSensorHW := "BG4624", + nInSensorNo := "cInBG4624", + stInOutSensor := "DB_Inputs".Sensors["cInBG4624"]); + // MT in Position (ILS-CV M4102) + #fbSensorInput(stInSensorHW := "BG4625", + nInSensorNo := "cInBG4625", + stInOutSensor := "DB_Inputs".Sensors["cInBG4625"]); + // Stausensor (ILS-CV M4202) + #fbSensorInput(stInSensorHW := "BG4631", + nInSensorNo := "cInBG4631", + stInOutSensor := "DB_Inputs".Sensors["cInBG4631"]); + // Sensor Förderer voll (ILS-CV M4202) + #fbSensorInput(stInSensorHW := "BG4632", + nInSensorNo := "cInBG4632", + stInOutSensor := "DB_Inputs".Sensors["cInBG4632"]); + // in Separator 1 (ILS-CV M4202) + #fbSensorInput(stInSensorHW := "BG4633", + nInSensorNo := "cInBG4633", + stInOutSensor := "DB_Inputs".Sensors["cInBG4633"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4202) + #fbSensorInput(stInSensorHW := "BG4634", + nInSensorNo := "cInBG4634", + stInOutSensor := "DB_Inputs".Sensors["cInBG4634"]); + // MT in Position (ILS-CV M4202) + #fbSensorInput(stInSensorHW := "BG4635", + nInSensorNo := "cInBG4635", + stInOutSensor := "DB_Inputs".Sensors["cInBG4635"]); + // in Separator (ILS-CV M4301) + #fbSensorInput(stInSensorHW := "BG4640", + nInSensorNo := "cInBG4640", + stInOutSensor := "DB_Inputs".Sensors["cInBG4640"]); + // MT in Position (ILS-CV M4301) + #fbSensorInput(stInSensorHW := "BG4641", + nInSensorNo := "cInBG4641", + stInOutSensor := "DB_Inputs".Sensors["cInBG4641"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4301) + #fbSensorInput(stInSensorHW := "BG4642", + nInSensorNo := "cInBG4642", + stInOutSensor := "DB_Inputs".Sensors["cInBG4642"]); + // Stausensor (ILS-CV M4301) + #fbSensorInput(stInSensorHW := "BG4643", + nInSensorNo := "cInBG4643", + stInOutSensor := "DB_Inputs".Sensors["cInBG4643"]); + // Sensor (ILS-CV M4301) + #fbSensorInput(stInSensorHW := "BG4644", + nInSensorNo := "cInBG4644", + stInOutSensor := "DB_Inputs".Sensors["cInBG4644"]); + // Stausensor empty MT-line 75% voll + #fbSensorInput(stInSensorHW := "BG4646", + nInSensorNo := "cInBG4646", + stInOutSensor := "DB_Inputs".Sensors["cInBG4646"]); + // Stausensor loaded MT-line 75% voll + #fbSensorInput(stInSensorHW := "BG4647", + nInSensorNo := "cInBG4647", + stInOutSensor := "DB_Inputs".Sensors["cInBG4647"]); + // in Separator (ILS-CV M4401) + #fbSensorInput(stInSensorHW := "BG4650", + nInSensorNo := "cInBG4650", + stInOutSensor := "DB_Inputs".Sensors["cInBG4650"]); + // MT in Position (ILS-CV M4401) + #fbSensorInput(stInSensorHW := "BG4651", + nInSensorNo := "cInBG4651", + stInOutSensor := "DB_Inputs".Sensors["cInBG4651"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4401) + #fbSensorInput(stInSensorHW := "BG4652", + nInSensorNo := "cInBG4652", + stInOutSensor := "DB_Inputs".Sensors["cInBG4652"]); + // Stausensor (ILS-CV M4401) + #fbSensorInput(stInSensorHW := "BG4653", + nInSensorNo := "cInBG4653", + stInOutSensor := "DB_Inputs".Sensors["cInBG4653"]); + // Sensor Förderer voll (ILS-CV M4401) + #fbSensorInput(stInSensorHW := "BG4654", + nInSensorNo := "cInBG4654", + stInOutSensor := "DB_Inputs".Sensors["cInBG4654"]); +END_FUNCTION_BLOCK diff --git a/results/FB_CallSensors_skel_UH04.scl b/results/FB_CallSensors_skel_UH04.scl new file mode 100644 index 0000000..070c0d9 --- /dev/null +++ b/results/FB_CallSensors_skel_UH04.scl @@ -0,0 +1,546 @@ +FUNCTION_BLOCK "FB_CallSensors_skel_UH04" +{ S7_Optimized_Access := 'TRUE' } +VERSION : 0.1 +// AUTOMATISCH GENERIERT — create_skel.py (134 Sensoren) + VAR + fbSensorInput : "FB_SensorInput"; + END_VAR + +BEGIN + // DT Anlage Aus + #fbSensorInput(stInSensorHW := "SF0000", + nInSensorNo := "cInSF0000", + stInOutSensor := "DB_Inputs".Sensors["cInSF0000"]); + // LDT Anlage Ein + #fbSensorInput(stInSensorHW := "SF0001", + nInSensorNo := "cInSF0001", + stInOutSensor := "DB_Inputs".Sensors["cInSF0001"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0002", + nInSensorNo := "cInSF0002", + stInOutSensor := "DB_Inputs".Sensors["cInSF0002"]); + // DT Lampentest + #fbSensorInput(stInSensorHW := "SF0003", + nInSensorNo := "cInSF0003", + stInOutSensor := "DB_Inputs".Sensors["cInSF0003"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0004", + nInSensorNo := "cInBP0004", + stInOutSensor := "DB_Inputs".Sensors["cInBP0004"]); + // Phasenausfall 400V + #fbSensorInput(stInSensorHW := "DI0005", + nInSensorNo := "cInDI0005", + stInOutSensor := "DB_Inputs".Sensors["cInDI0005"]); + // Vorsicherung 400V UC Reserve + #fbSensorInput(stInSensorHW := "DI0006", + nInSensorNo := "cInDI0006", + stInOutSensor := "DB_Inputs".Sensors["cInDI0006"]); + // Feedback Hauptschütze aktiv + #fbSensorInput(stInSensorHW := "DI0013", + nInSensorNo := "cInDI0013", + stInOutSensor := "DB_Inputs".Sensors["cInDI0013"]); + // Feedback Koppelrelais E-Stop-IF (QA0660/QA0661) + #fbSensorInput(stInSensorHW := "DI0014", + nInSensorNo := "cInDI0014", + stInOutSensor := "DB_Inputs".Sensors["cInDI0014"]); + // Feedback Koppelrelais E-Stop-IF + #fbSensorInput(stInSensorHW := "DI0015", + nInSensorNo := "cInDI0015", + stInOutSensor := "DB_Inputs".Sensors["cInDI0015"]); + // Sicherungsautomatenfall + #fbSensorInput(stInSensorHW := "DI0016", + nInSensorNo := "cInDI0016", + stInOutSensor := "DB_Inputs".Sensors["cInDI0016"]); + // Vorsicherung 24V OK (FC021) + #fbSensorInput(stInSensorHW := "DI0021", + nInSensorNo := "cInDI0021", + stInOutSensor := "DB_Inputs".Sensors["cInDI0021"]); + // Vorsicherung 24V OK (FC022) + #fbSensorInput(stInSensorHW := "DI0022", + nInSensorNo := "cInDI0022", + stInOutSensor := "DB_Inputs".Sensors["cInDI0022"]); + // Vorsicherung 24V OK (FC023) + #fbSensorInput(stInSensorHW := "DI0023", + nInSensorNo := "cInDI0023", + stInOutSensor := "DB_Inputs".Sensors["cInDI0023"]); + // MT freigeben UZ0403, Workstation MPS 3 + #fbSensorInput(stInSensorHW := "SF0025", + nInSensorNo := "cInSF0025", + stInOutSensor := "DB_Inputs".Sensors["cInSF0025"]); + // MT freigeben UZ0402, Workstation MPS 2 + #fbSensorInput(stInSensorHW := "SF0026", + nInSensorNo := "cInSF0026", + stInOutSensor := "DB_Inputs".Sensors["cInSF0026"]); + // MT freigeben UZ0401, Workstation MPS 1 + #fbSensorInput(stInSensorHW := "SF0027", + nInSensorNo := "cInSF0027", + stInOutSensor := "DB_Inputs".Sensors["cInSF0027"]); + // IF BMZ "fire alarm" 2 + #fbSensorInput(stInSensorHW := "DI0033", + nInSensorNo := "cInDI0033", + stInOutSensor := "DB_Inputs".Sensors["cInDI0033"]); + // IF BMZ "fire alarm" 1 + #fbSensorInput(stInSensorHW := "DI0034", + nInSensorNo := "cInDI0034", + stInOutSensor := "DB_Inputs".Sensors["cInDI0034"]); + // IF BST 4 "No fire alarm" + #fbSensorInput(stInSensorHW := "DI0035", + nInSensorNo := "cInDI0035", + stInOutSensor := "DB_Inputs".Sensors["cInDI0035"]); + // IF BST 4 "Non fault" + #fbSensorInput(stInSensorHW := "DI0036", + nInSensorNo := "cInDI0036", + stInOutSensor := "DB_Inputs".Sensors["cInDI0036"]); + // IF BST 4 "FPC opened" + #fbSensorInput(stInSensorHW := "DI0037", + nInSensorNo := "cInDI0037", + stInOutSensor := "DB_Inputs".Sensors["cInDI0037"]); + // Reset UZ0409 + #fbSensorInput(stInSensorHW := "SF0051", + nInSensorNo := "cInSF0051", + stInOutSensor := "DB_Inputs".Sensors["cInSF0051"]); + // Reset UZ0403 + #fbSensorInput(stInSensorHW := "SF0053", + nInSensorNo := "cInSF0053", + stInOutSensor := "DB_Inputs".Sensors["cInSF0053"]); + // Reset UZ0402 + #fbSensorInput(stInSensorHW := "SF0055", + nInSensorNo := "cInSF0055", + stInOutSensor := "DB_Inputs".Sensors["cInSF0055"]); + // Reset UZ0401 + #fbSensorInput(stInSensorHW := "SF0057", + nInSensorNo := "cInSF0057", + stInOutSensor := "DB_Inputs".Sensors["cInSF0057"]); + // MSS ausgelöst FC0060 + #fbSensorInput(stInSensorHW := "FC0060", + nInSensorNo := "cInFC0060", + stInOutSensor := "DB_Inputs".Sensors["cInFC0060"]); + // MSS ausgelöst FC0061 + #fbSensorInput(stInSensorHW := "FC0061", + nInSensorNo := "cInFC0061", + stInOutSensor := "DB_Inputs".Sensors["cInFC0061"]); + // MSS ausgelöst FC0062 + #fbSensorInput(stInSensorHW := "FC0062", + nInSensorNo := "cInFC0062", + stInOutSensor := "DB_Inputs".Sensors["cInFC0062"]); + // MSS ausgelöst FC0063 + #fbSensorInput(stInSensorHW := "FC0063", + nInSensorNo := "cInFC0063", + stInOutSensor := "DB_Inputs".Sensors["cInFC0063"]); + // MSS ausgelöst FC0064 + #fbSensorInput(stInSensorHW := "FC0064", + nInSensorNo := "cInFC0064", + stInOutSensor := "DB_Inputs".Sensors["cInFC0064"]); + // MSS ausgelöst FC0065 + #fbSensorInput(stInSensorHW := "FC0065", + nInSensorNo := "cInFC0065", + stInOutSensor := "DB_Inputs".Sensors["cInFC0065"]); + // MSS ausgelöst FC0066 + #fbSensorInput(stInSensorHW := "FC0066", + nInSensorNo := "cInFC0066", + stInOutSensor := "DB_Inputs".Sensors["cInFC0066"]); + // MSS ausgelöst FC0070 + #fbSensorInput(stInSensorHW := "FC0070", + nInSensorNo := "cInFC0070", + stInOutSensor := "DB_Inputs".Sensors["cInFC0070"]); + // MSS ausgelöst FC0071 + #fbSensorInput(stInSensorHW := "FC0071", + nInSensorNo := "cInFC0071", + stInOutSensor := "DB_Inputs".Sensors["cInFC0071"]); + // MSS ausgelöst FC0072 + #fbSensorInput(stInSensorHW := "FC0072", + nInSensorNo := "cInFC0072", + stInOutSensor := "DB_Inputs".Sensors["cInFC0072"]); + // MSS ausgelöst FC0073 + #fbSensorInput(stInSensorHW := "FC0073", + nInSensorNo := "cInFC0073", + stInOutSensor := "DB_Inputs".Sensors["cInFC0073"]); + // MSS ausgelöst FC0074 + #fbSensorInput(stInSensorHW := "FC0074", + nInSensorNo := "cInFC0074", + stInOutSensor := "DB_Inputs".Sensors["cInFC0074"]); + // MSS ausgelöst FC0075 (Reserve) + #fbSensorInput(stInSensorHW := "FC0075", + nInSensorNo := "cInFC0075", + stInOutSensor := "DB_Inputs".Sensors["cInFC0075"]); + // Not Halt Kanal 1 UH04 + #fbSensorInput(stInSensorHW := "SF0400", + nInSensorNo := "cInSF0400", + stInOutSensor := "DB_Inputs".Sensors["cInSF0400"]); + // Not Halt Kanal 2 UH04 + #fbSensorInput(stInSensorHW := "SF0404", + nInSensorNo := "cInSF0404", + stInOutSensor := "DB_Inputs".Sensors["cInSF0404"]); + // Not Halt Schnittstelle CH1 (UH06) + #fbSensorInput(stInSensorHW := "SF0471", + nInSensorNo := "cInSF0471", + stInOutSensor := "DB_Inputs".Sensors["cInSF0471"]); + // Not Halt Schnittstelle CH2 (Reserve) + #fbSensorInput(stInSensorHW := "SF0472", + nInSensorNo := "cInSF0472", + stInOutSensor := "DB_Inputs".Sensors["cInSF0472"]); + // Not Halt Kanal 1 UZ0409 + #fbSensorInput(stInSensorHW := "SF0473", + nInSensorNo := "cInSF0473", + stInOutSensor := "DB_Inputs".Sensors["cInSF0473"]); + // Not Halt Schnittstelle CH1 (UH06) + #fbSensorInput(stInSensorHW := "SF0475", + nInSensorNo := "cInSF0475", + stInOutSensor := "DB_Inputs".Sensors["cInSF0475"]); + // Not Halt Schnittstelle CH2 (Reserve) + #fbSensorInput(stInSensorHW := "SF0476", + nInSensorNo := "cInSF0476", + stInOutSensor := "DB_Inputs".Sensors["cInSF0476"]); + // Not Halt Kanal 2 UZ0409 + #fbSensorInput(stInSensorHW := "SF0477", + nInSensorNo := "cInSF0477", + stInOutSensor := "DB_Inputs".Sensors["cInSF0477"]); + // Sensor Förderer voll (ILS-CV M4000) + #fbSensorInput(stInSensorHW := "BG3240", + nInSensorNo := "cInBG3240", + stInOutSensor := "DB_Inputs".Sensors["cInBG3240"]); + // MT in Position MPS 3 (AMR ILS-CV M04001) + #fbSensorInput(stInSensorHW := "BG3241", + nInSensorNo := "cInBG3241", + stInOutSensor := "DB_Inputs".Sensors["cInBG3241"]); + // in Separator (ILS-CV M4001) + #fbSensorInput(stInSensorHW := "BG3242", + nInSensorNo := "cInBG3242", + stInOutSensor := "DB_Inputs".Sensors["cInBG3242"]); + // Stausensor (AMR ILS-CV M4000) + #fbSensorInput(stInSensorHW := "BG3243", + nInSensorNo := "cInBG3243", + stInOutSensor := "DB_Inputs".Sensors["cInBG3243"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4001) + #fbSensorInput(stInSensorHW := "BG3244", + nInSensorNo := "cInBG3244", + stInOutSensor := "DB_Inputs".Sensors["cInBG3244"]); + // Sensor Förderer voll (ILS-CV M4001) + #fbSensorInput(stInSensorHW := "BG3245", + nInSensorNo := "cInBG3245", + stInOutSensor := "DB_Inputs".Sensors["cInBG3245"]); + // Stausensor vor Vario Förderer (ILS-CV M4001) + #fbSensorInput(stInSensorHW := "BG3246", + nInSensorNo := "cInBG3246", + stInOutSensor := "DB_Inputs".Sensors["cInBG3246"]); + // in Separator vor BST 4 (ILS-CV M4001) + #fbSensorInput(stInSensorHW := "BG3247", + nInSensorNo := "cInBG3247", + stInOutSensor := "DB_Inputs".Sensors["cInBG3247"]); + // in Separator (ILS-CV M4011) + #fbSensorInput(stInSensorHW := "BG3250", + nInSensorNo := "cInBG3250", + stInOutSensor := "DB_Inputs".Sensors["cInBG3250"]); + // Stausensor (AMR ILS-CV M4503) + #fbSensorInput(stInSensorHW := "BG3251", + nInSensorNo := "cInBG3251", + stInOutSensor := "DB_Inputs".Sensors["cInBG3251"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M4011) + #fbSensorInput(stInSensorHW := "BG3253", + nInSensorNo := "cInBG3253", + stInOutSensor := "DB_Inputs".Sensors["cInBG3253"]); + // MT in Position (ILS-CV M4011) + #fbSensorInput(stInSensorHW := "BG3255", + nInSensorNo := "cInBG3255", + stInOutSensor := "DB_Inputs".Sensors["cInBG3255"]); + // Sensor Förderer voll (ILS-CV M4011) + #fbSensorInput(stInSensorHW := "BG3256", + nInSensorNo := "cInBG3256", + stInOutSensor := "DB_Inputs".Sensors["cInBG3256"]); + // in Separator 4 (ILS-CV M0401) + #fbSensorInput(stInSensorHW := "BG3260", + nInSensorNo := "cInBG3260", + stInOutSensor := "DB_Inputs".Sensors["cInBG3260"]); + // MT in Position (AMR ILS-CV M0401) + #fbSensorInput(stInSensorHW := "BG3261", + nInSensorNo := "cInBG3261", + stInOutSensor := "DB_Inputs".Sensors["cInBG3261"]); + // Abfrage Mitnehmerfinger in Position (AMR ILS-CV M0401) + #fbSensorInput(stInSensorHW := "BG3262", + nInSensorNo := "cInBG3262", + stInOutSensor := "DB_Inputs".Sensors["cInBG3262"]); + // Stausensor nach BST 4 (AMR ILS-CV M4011) + #fbSensorInput(stInSensorHW := "BG3264", + nInSensorNo := "cInBG3264", + stInOutSensor := "DB_Inputs".Sensors["cInBG3264"]); + // in Separator 6 (AMR KR-M4003) + #fbSensorInput(stInSensorHW := "BG3300", + nInSensorNo := "cInBG3300", + stInOutSensor := "DB_Inputs".Sensors["cInBG3300"]); + // Stausensor 6 (AMR ILS-KR M4003) + #fbSensorInput(stInSensorHW := "BG3301", + nInSensorNo := "cInBG3301", + stInOutSensor := "DB_Inputs".Sensors["cInBG3301"]); + // Stausensor (AMR KR-M4003) + #fbSensorInput(stInSensorHW := "BG3303", + nInSensorNo := "cInBG3303", + stInOutSensor := "DB_Inputs".Sensors["cInBG3303"]); + // in Separator vor MPS 3 (AMR KR-M4003) + #fbSensorInput(stInSensorHW := "BG3304", + nInSensorNo := "cInBG3304", + stInOutSensor := "DB_Inputs".Sensors["cInBG3304"]); + // Stausensor (AMR ILS-CV M4004) + #fbSensorInput(stInSensorHW := "BG3311", + nInSensorNo := "cInBG3311", + stInOutSensor := "DB_Inputs".Sensors["cInBG3311"]); + // Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4004) + #fbSensorInput(stInSensorHW := "BG3312", + nInSensorNo := "cInBG3312", + stInOutSensor := "DB_Inputs".Sensors["cInBG3312"]); + // Sensor Förderer voll (AMR ILS-CV M4004) MPS 3 + #fbSensorInput(stInSensorHW := "BG3313", + nInSensorNo := "cInBG3313", + stInOutSensor := "DB_Inputs".Sensors["cInBG3313"]); + // MT in Entladeposition MPS 3 (AMR ILS-CV M4005) + #fbSensorInput(stInSensorHW := "BG3314", + nInSensorNo := "cInBG3314", + stInOutSensor := "DB_Inputs".Sensors["cInBG3314"]); + // Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4005) MPS 3 + #fbSensorInput(stInSensorHW := "BG3315", + nInSensorNo := "cInBG3315", + stInOutSensor := "DB_Inputs".Sensors["cInBG3315"]); + // MT in Position MPS 3 (AMR ILS-CV M4004) + #fbSensorInput(stInSensorHW := "BG3316", + nInSensorNo := "cInBG3316", + stInOutSensor := "DB_Inputs".Sensors["cInBG3316"]); + // Sensor Förderer voll (AMR ILS-CV M4005) + #fbSensorInput(stInSensorHW := "BG3317", + nInSensorNo := "cInBG3317", + stInOutSensor := "DB_Inputs".Sensors["cInBG3317"]); + // Stausensor (AMR ILS-CV M4005) + #fbSensorInput(stInSensorHW := "BG3320", + nInSensorNo := "cInBG3320", + stInOutSensor := "DB_Inputs".Sensors["cInBG3320"]); + // in Separator Ausfahrt MPS 3 (AMR ILS-CV M4005) + #fbSensorInput(stInSensorHW := "BG3321", + nInSensorNo := "cInBG3321", + stInOutSensor := "DB_Inputs".Sensors["cInBG3321"]); + // Stausensor Ausfahrt MPS 03 (AMR ILS-KR M4003) + #fbSensorInput(stInSensorHW := "BG3322", + nInSensorNo := "cInBG3322", + stInOutSensor := "DB_Inputs".Sensors["cInBG3322"]); + // MT in Position MPS 3 (AMR ILS-CV M4005) + #fbSensorInput(stInSensorHW := "BG3324", + nInSensorNo := "cInBG3324", + stInOutSensor := "DB_Inputs".Sensors["cInBG3324"]); + // MT ist beladen MPS 3 (AMR ILS-CV M4005) + #fbSensorInput(stInSensorHW := "BG3325", + nInSensorNo := "cInBG3325", + stInOutSensor := "DB_Inputs".Sensors["cInBG3325"]); + // in Separator (AMR ILS-CV M4005) + #fbSensorInput(stInSensorHW := "BG3326", + nInSensorNo := "cInBG3326", + stInOutSensor := "DB_Inputs".Sensors["cInBG3326"]); + // Stausensor (AMR ILS-CV M4004) + #fbSensorInput(stInSensorHW := "BG3327", + nInSensorNo := "cInBG3327", + stInOutSensor := "DB_Inputs".Sensors["cInBG3327"]); + // in Separator (AMR ILS-KR M4003) + #fbSensorInput(stInSensorHW := "BG3360", + nInSensorNo := "cInBG3360", + stInOutSensor := "DB_Inputs".Sensors["cInBG3360"]); + // MT ist beladen (AMR KR-M4003) + #fbSensorInput(stInSensorHW := "BG3361", + nInSensorNo := "cInBG3361", + stInOutSensor := "DB_Inputs".Sensors["cInBG3361"]); + // Stausensor 5 (AMR ILS-KR M4003) + #fbSensorInput(stInSensorHW := "BG3362", + nInSensorNo := "cInBG3362", + stInOutSensor := "DB_Inputs".Sensors["cInBG3362"]); + // in Separator 5 (AMR ILS-KR M4003) + #fbSensorInput(stInSensorHW := "BG3363", + nInSensorNo := "cInBG3363", + stInOutSensor := "DB_Inputs".Sensors["cInBG3363"]); + // Stausensor 4 (AMR ILS-KR M4003) + #fbSensorInput(stInSensorHW := "BG3367", + nInSensorNo := "cInBG3367", + stInOutSensor := "DB_Inputs".Sensors["cInBG3367"]); + // in Separator (AMR ILS-CV M4006) + #fbSensorInput(stInSensorHW := "BG3370", + nInSensorNo := "cInBG3370", + stInOutSensor := "DB_Inputs".Sensors["cInBG3370"]); + // Stausensor 3 (AMR ILS-CV M4006) + #fbSensorInput(stInSensorHW := "BG3371", + nInSensorNo := "cInBG3371", + stInOutSensor := "DB_Inputs".Sensors["cInBG3371"]); + // Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4006) + #fbSensorInput(stInSensorHW := "BG3372", + nInSensorNo := "cInBG3372", + stInOutSensor := "DB_Inputs".Sensors["cInBG3372"]); + // Sensor Förderer voll (AMR ILS-CV M4006) + #fbSensorInput(stInSensorHW := "BG3373", + nInSensorNo := "cInBG3373", + stInOutSensor := "DB_Inputs".Sensors["cInBG3373"]); + // MT IN Entladeposition MPS- (AMR ILS-CV M4007) + #fbSensorInput(stInSensorHW := "BG3374", + nInSensorNo := "cInBG3374", + stInOutSensor := "DB_Inputs".Sensors["cInBG3374"]); + // Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4007) MPS 2 + #fbSensorInput(stInSensorHW := "BG3375", + nInSensorNo := "cInBG3375", + stInOutSensor := "DB_Inputs".Sensors["cInBG3375"]); + // MT in Position MPS 2 (AMR ILS-CV M4006) + #fbSensorInput(stInSensorHW := "BG3376", + nInSensorNo := "cInBG3376", + stInOutSensor := "DB_Inputs".Sensors["cInBG3376"]); + // Sensor Förderer voll (AMR ILS-CV M4007) + #fbSensorInput(stInSensorHW := "BG3377", + nInSensorNo := "cInBG3377", + stInOutSensor := "DB_Inputs".Sensors["cInBG3377"]); + // Stausensor (AMR ILS-CV M4007) + #fbSensorInput(stInSensorHW := "BG3380", + nInSensorNo := "cInBG3380", + stInOutSensor := "DB_Inputs".Sensors["cInBG3380"]); + // in Separator Ausfahrt MPS 2 (AMR ILS-CV M4007) + #fbSensorInput(stInSensorHW := "BG3381", + nInSensorNo := "cInBG3381", + stInOutSensor := "DB_Inputs".Sensors["cInBG3381"]); + // Stausensor Ausfahrt MPS 02 (AMR ILS-KR M04003) + #fbSensorInput(stInSensorHW := "BG3382", + nInSensorNo := "cInBG3382", + stInOutSensor := "DB_Inputs".Sensors["cInBG3382"]); + // in Separator (AMR ILS-KR M4003) + #fbSensorInput(stInSensorHW := "BG3383", + nInSensorNo := "cInBG3383", + stInOutSensor := "DB_Inputs".Sensors["cInBG3383"]); + // MT in Position MPS 2 (AMR ILS-CV M4007) + #fbSensorInput(stInSensorHW := "BG3384", + nInSensorNo := "cInBG3384", + stInOutSensor := "DB_Inputs".Sensors["cInBG3384"]); + // MT ist beladen MPS 2 (AMR ILS-CV M4007) + #fbSensorInput(stInSensorHW := "BG3385", + nInSensorNo := "cInBG3385", + stInOutSensor := "DB_Inputs".Sensors["cInBG3385"]); + // in Separator (AMR ILS-CV M4002) + #fbSensorInput(stInSensorHW := "BG3386", + nInSensorNo := "cInBG3386", + stInOutSensor := "DB_Inputs".Sensors["cInBG3386"]); + // Stausensor 3 (AMR ILS-CV M4002) + #fbSensorInput(stInSensorHW := "BG3387", + nInSensorNo := "cInBG3387", + stInOutSensor := "DB_Inputs".Sensors["cInBG3387"]); + // Sensor Förderer voll (AMR ILS-CV M4002) + #fbSensorInput(stInSensorHW := "BG3390", + nInSensorNo := "cInBG3390", + stInOutSensor := "DB_Inputs".Sensors["cInBG3390"]); + // in Separator (AMR ILS-CV M4010) + #fbSensorInput(stInSensorHW := "BG3391", + nInSensorNo := "cInBG3391", + stInOutSensor := "DB_Inputs".Sensors["cInBG3391"]); + // MT in Position (ILS-CV M4010) + #fbSensorInput(stInSensorHW := "BG3392", + nInSensorNo := "cInBG3392", + stInOutSensor := "DB_Inputs".Sensors["cInBG3392"]); + // Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4010) + #fbSensorInput(stInSensorHW := "BG3393", + nInSensorNo := "cInBG3393", + stInOutSensor := "DB_Inputs".Sensors["cInBG3393"]); + // Stausensor (AMR ILS-CV M4006) + #fbSensorInput(stInSensorHW := "BG3396", + nInSensorNo := "cInBG3396", + stInOutSensor := "DB_Inputs".Sensors["cInBG3396"]); + // in Separator (AMR ILS-CV M4007) + #fbSensorInput(stInSensorHW := "BG3397", + nInSensorNo := "cInBG3397", + stInOutSensor := "DB_Inputs".Sensors["cInBG3397"]); + // in Separator (AMR ILS-KR M4003) + #fbSensorInput(stInSensorHW := "BG3400", + nInSensorNo := "cInBG3400", + stInOutSensor := "DB_Inputs".Sensors["cInBG3400"]); + // in Separator (AMR ILS-CV M4002) + #fbSensorInput(stInSensorHW := "BG3420", + nInSensorNo := "cInBG3420", + stInOutSensor := "DB_Inputs".Sensors["cInBG3420"]); + // Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4002) + #fbSensorInput(stInSensorHW := "BG3421", + nInSensorNo := "cInBG3421", + stInOutSensor := "DB_Inputs".Sensors["cInBG3421"]); + // Stausensor nach BST 4 (AMR ILS-CV M4010) + #fbSensorInput(stInSensorHW := "BG3423", + nInSensorNo := "cInBG3423", + stInOutSensor := "DB_Inputs".Sensors["cInBG3423"]); + // Sensor Förderer voll (ILS-CV M4010) + #fbSensorInput(stInSensorHW := "BG3425", + nInSensorNo := "cInBG3425", + stInOutSensor := "DB_Inputs".Sensors["cInBG3425"]); + // MT in Position (ILS-CV M4002) + #fbSensorInput(stInSensorHW := "BG3426", + nInSensorNo := "cInBG3426", + stInOutSensor := "DB_Inputs".Sensors["cInBG3426"]); + // in Separator vor MPS 1 (AMR KR-M4003) + #fbSensorInput(stInSensorHW := "BG3430", + nInSensorNo := "cInBG3430", + stInOutSensor := "DB_Inputs".Sensors["cInBG3430"]); + // Stausensor (AMR ILS-CV M4009) + #fbSensorInput(stInSensorHW := "BG3431", + nInSensorNo := "cInBG3431", + stInOutSensor := "DB_Inputs".Sensors["cInBG3431"]); + // Rad dreht (AMR KR-M4003) + #fbSensorInput(stInSensorHW := "BG3432", + nInSensorNo := "cInBG3432", + stInOutSensor := "DB_Inputs".Sensors["cInBG3432"]); + // Stausensor (AMR ILS-KR M4003) + #fbSensorInput(stInSensorHW := "BG3433", + nInSensorNo := "cInBG3433", + stInOutSensor := "DB_Inputs".Sensors["cInBG3433"]); + // in Separator (AMR KR-M4003) + #fbSensorInput(stInSensorHW := "BG3435", + nInSensorNo := "cInBG3435", + stInOutSensor := "DB_Inputs".Sensors["cInBG3435"]); + // in Separator (AMR ILS-CV M4009) + #fbSensorInput(stInSensorHW := "BG3436", + nInSensorNo := "cInBG3436", + stInOutSensor := "DB_Inputs".Sensors["cInBG3436"]); + // Stausensor (AMR ILS-CV M4008) + #fbSensorInput(stInSensorHW := "BG3437", + nInSensorNo := "cInBG3437", + stInOutSensor := "DB_Inputs".Sensors["cInBG3437"]); + // in Separator (AMR ILS-CV M4008) + #fbSensorInput(stInSensorHW := "BG3440", + nInSensorNo := "cInBG3440", + stInOutSensor := "DB_Inputs".Sensors["cInBG3440"]); + // Stausensor 3 (AMR ILS-CV M4008) + #fbSensorInput(stInSensorHW := "BG3441", + nInSensorNo := "cInBG3441", + stInOutSensor := "DB_Inputs".Sensors["cInBG3441"]); + // Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4008) + #fbSensorInput(stInSensorHW := "BG3442", + nInSensorNo := "cInBG3442", + stInOutSensor := "DB_Inputs".Sensors["cInBG3442"]); + // Sensor Förderer voll (AMR ILS-CV M4008) + #fbSensorInput(stInSensorHW := "BG3443", + nInSensorNo := "cInBG3443", + stInOutSensor := "DB_Inputs".Sensors["cInBG3443"]); + // MT IN Entladeposition MPS- (AMR ILS-CV M4009) + #fbSensorInput(stInSensorHW := "BG3444", + nInSensorNo := "cInBG3444", + stInOutSensor := "DB_Inputs".Sensors["cInBG3444"]); + // Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4009) + #fbSensorInput(stInSensorHW := "BG3445", + nInSensorNo := "cInBG3445", + stInOutSensor := "DB_Inputs".Sensors["cInBG3445"]); + // MT in Position MPS 1 (AMR ILS-CV M4008) + #fbSensorInput(stInSensorHW := "BG3446", + nInSensorNo := "cInBG3446", + stInOutSensor := "DB_Inputs".Sensors["cInBG3446"]); + // Sensor Förderer voll (AMR ILS-CV M4009) + #fbSensorInput(stInSensorHW := "BG3447", + nInSensorNo := "cInBG3447", + stInOutSensor := "DB_Inputs".Sensors["cInBG3447"]); + // Stausensor Ausfahrt MPS 01 (AMR ILS-KR M4003) + #fbSensorInput(stInSensorHW := "BG3450", + nInSensorNo := "cInBG3450", + stInOutSensor := "DB_Inputs".Sensors["cInBG3450"]); + // in Separator Ausfahrt MPS 1 (AMR ILS-CV M4009) + #fbSensorInput(stInSensorHW := "BG3451", + nInSensorNo := "cInBG3451", + stInOutSensor := "DB_Inputs".Sensors["cInBG3451"]); + // MT in Position MPS 1 (AMR ILS-CV M4009) + #fbSensorInput(stInSensorHW := "BG3454", + nInSensorNo := "cInBG3454", + stInOutSensor := "DB_Inputs".Sensors["cInBG3454"]); + // MT ist beladen MPS 1 (AMR ILS-CV M4009) + #fbSensorInput(stInSensorHW := "BG3455", + nInSensorNo := "cInBG3455", + stInOutSensor := "DB_Inputs".Sensors["cInBG3455"]); +END_FUNCTION_BLOCK diff --git a/results/FB_CallSensors_skel_UH05.scl b/results/FB_CallSensors_skel_UH05.scl new file mode 100644 index 0000000..bbaf8a6 --- /dev/null +++ b/results/FB_CallSensors_skel_UH05.scl @@ -0,0 +1,654 @@ +FUNCTION_BLOCK "FB_CallSensors_skel_UH05" +{ S7_Optimized_Access := 'TRUE' } +VERSION : 0.1 +// AUTOMATISCH GENERIERT — create_skel.py (161 Sensoren) + VAR + fbSensorInput : "FB_SensorInput"; + END_VAR + +BEGIN + // DT Anlage Aus + #fbSensorInput(stInSensorHW := "SF0000", + nInSensorNo := "cInSF0000", + stInOutSensor := "DB_Inputs".Sensors["cInSF0000"]); + // LDT Anlage Ein + #fbSensorInput(stInSensorHW := "SF0001", + nInSensorNo := "cInSF0001", + stInOutSensor := "DB_Inputs".Sensors["cInSF0001"]); + // LDT Reset + #fbSensorInput(stInSensorHW := "SF0002", + nInSensorNo := "cInSF0002", + stInOutSensor := "DB_Inputs".Sensors["cInSF0002"]); + // DT Lampentest + #fbSensorInput(stInSensorHW := "SF0003", + nInSensorNo := "cInSF0003", + stInOutSensor := "DB_Inputs".Sensors["cInSF0003"]); + // Druckschalter Druckluft OK + #fbSensorInput(stInSensorHW := "BP0004", + nInSensorNo := "cInBP0004", + stInOutSensor := "DB_Inputs".Sensors["cInBP0004"]); + // Phasenausfall 400V + #fbSensorInput(stInSensorHW := "DI0005", + nInSensorNo := "cInDI0005", + stInOutSensor := "DB_Inputs".Sensors["cInDI0005"]); + // Vorsicherung 400V UC Reserve + #fbSensorInput(stInSensorHW := "DI0006", + nInSensorNo := "cInDI0006", + stInOutSensor := "DB_Inputs".Sensors["cInDI0006"]); + // Feedback Koppelrelais E-Stop-IF UH07 (QA0612/QA0613) + #fbSensorInput(stInSensorHW := "DI0012", + nInSensorNo := "cInDI0012", + stInOutSensor := "DB_Inputs".Sensors["cInDI0012"]); + // Feedback Hauptschütze aktiv (QA0060 - QA0070) + #fbSensorInput(stInSensorHW := "DI0013", + nInSensorNo := "cInDI0013", + stInOutSensor := "DB_Inputs".Sensors["cInDI0013"]); + // Feedback Koppelrelais E-Stop-IF (QA0660/QA0661) + #fbSensorInput(stInSensorHW := "DI0014", + nInSensorNo := "cInDI0014", + stInOutSensor := "DB_Inputs".Sensors["cInDI0014"]); + // Feedback Koppelrelais E-Stop-IF + #fbSensorInput(stInSensorHW := "DI0015", + nInSensorNo := "cInDI0015", + stInOutSensor := "DB_Inputs".Sensors["cInDI0015"]); + // Sicherungsautomatenfall + #fbSensorInput(stInSensorHW := "DI0016", + nInSensorNo := "cInDI0016", + stInOutSensor := "DB_Inputs".Sensors["cInDI0016"]); + // Vorsicherung 24V OK (FC021) + #fbSensorInput(stInSensorHW := "DI0021", + nInSensorNo := "cInDI0021", + stInOutSensor := "DB_Inputs".Sensors["cInDI0021"]); + // Vorsicherung 24V OK (FC022) + #fbSensorInput(stInSensorHW := "DI0022", + nInSensorNo := "cInDI0022", + stInOutSensor := "DB_Inputs".Sensors["cInDI0022"]); + // Vorsicherung 24V OK (FC023) + #fbSensorInput(stInSensorHW := "DI0023", + nInSensorNo := "cInDI0023", + stInOutSensor := "DB_Inputs".Sensors["cInDI0023"]); + // IF BMZ "fire alarm" + #fbSensorInput(stInSensorHW := "DI0034", + nInSensorNo := "cInDI0034", + stInOutSensor := "DB_Inputs".Sensors["cInDI0034"]); + // IF BST "No fire alarm" + #fbSensorInput(stInSensorHW := "DI0035", + nInSensorNo := "cInDI0035", + stInOutSensor := "DB_Inputs".Sensors["cInDI0035"]); + // IF BST "Non fault" + #fbSensorInput(stInSensorHW := "DI0036", + nInSensorNo := "cInDI0036", + stInOutSensor := "DB_Inputs".Sensors["cInDI0036"]); + // IF BST "FPC opened" + #fbSensorInput(stInSensorHW := "DI0037", + nInSensorNo := "cInDI0037", + stInOutSensor := "DB_Inputs".Sensors["cInDI0037"]); + // Reset UZ0501 + #fbSensorInput(stInSensorHW := "SF0041", + nInSensorNo := "cInSF0041", + stInOutSensor := "DB_Inputs".Sensors["cInSF0041"]); + // Freigabe UZ0502 + #fbSensorInput(stInSensorHW := "SF0042", + nInSensorNo := "cInSF0042", + stInOutSensor := "DB_Inputs".Sensors["cInSF0042"]); + // Reset UZ0502 + #fbSensorInput(stInSensorHW := "SF0043", + nInSensorNo := "cInSF0043", + stInOutSensor := "DB_Inputs".Sensors["cInSF0043"]); + // Freigabe UZ0504 + #fbSensorInput(stInSensorHW := "SF0046", + nInSensorNo := "cInSF0046", + stInOutSensor := "DB_Inputs".Sensors["cInSF0046"]); + // Reset UZ0504 + #fbSensorInput(stInSensorHW := "SF0047", + nInSensorNo := "cInSF0047", + stInOutSensor := "DB_Inputs".Sensors["cInSF0047"]); + // Freigeben UZ0506 + #fbSensorInput(stInSensorHW := "SF0052", + nInSensorNo := "cInSF0052", + stInOutSensor := "DB_Inputs".Sensors["cInSF0052"]); + // Reset UZ0506 + #fbSensorInput(stInSensorHW := "SF0053", + nInSensorNo := "cInSF0053", + stInOutSensor := "DB_Inputs".Sensors["cInSF0053"]); + // Reset UZ0507 + #fbSensorInput(stInSensorHW := "SF0055", + nInSensorNo := "cInSF0055", + stInOutSensor := "DB_Inputs".Sensors["cInSF0055"]); + // Freigabe UZ0501 + #fbSensorInput(stInSensorHW := "SF0056", + nInSensorNo := "cInSF0056", + stInOutSensor := "DB_Inputs".Sensors["cInSF0056"]); + // MSS ausgelöst FC0060 + #fbSensorInput(stInSensorHW := "FC0060", + nInSensorNo := "cInFC0060", + stInOutSensor := "DB_Inputs".Sensors["cInFC0060"]); + // MSS ausgelöst FC0061 + #fbSensorInput(stInSensorHW := "FC0061", + nInSensorNo := "cInFC0061", + stInOutSensor := "DB_Inputs".Sensors["cInFC0061"]); + // MSS ausgelöst FC0062 + #fbSensorInput(stInSensorHW := "FC0062", + nInSensorNo := "cInFC0062", + stInOutSensor := "DB_Inputs".Sensors["cInFC0062"]); + // MSS ausgelöst FC0063 + #fbSensorInput(stInSensorHW := "FC0063", + nInSensorNo := "cInFC0063", + stInOutSensor := "DB_Inputs".Sensors["cInFC0063"]); + // MSS ausgelöst FC0064 + #fbSensorInput(stInSensorHW := "FC0064", + nInSensorNo := "cInFC0064", + stInOutSensor := "DB_Inputs".Sensors["cInFC0064"]); + // MSS ausgelöst FC0065 + #fbSensorInput(stInSensorHW := "FC0065", + nInSensorNo := "cInFC0065", + stInOutSensor := "DB_Inputs".Sensors["cInFC0065"]); + // MSS ausgelöst FC0066 + #fbSensorInput(stInSensorHW := "FC0066", + nInSensorNo := "cInFC0066", + stInOutSensor := "DB_Inputs".Sensors["cInFC0066"]); + // MSS ausgelöst FC0067 + #fbSensorInput(stInSensorHW := "FC0067", + nInSensorNo := "cInFC0067", + stInOutSensor := "DB_Inputs".Sensors["cInFC0067"]); + // MSS ausgelöst FC0070 + #fbSensorInput(stInSensorHW := "FC0070", + nInSensorNo := "cInFC0070", + stInOutSensor := "DB_Inputs".Sensors["cInFC0070"]); + // MSS ausgelöst FC0071 + #fbSensorInput(stInSensorHW := "FC0071", + nInSensorNo := "cInFC0071", + stInOutSensor := "DB_Inputs".Sensors["cInFC0071"]); + // MSS ausgelöst FC0072 + #fbSensorInput(stInSensorHW := "FC0072", + nInSensorNo := "cInFC0072", + stInOutSensor := "DB_Inputs".Sensors["cInFC0072"]); + // Not Halt Kanal 1 UH05 + #fbSensorInput(stInSensorHW := "SF0400", + nInSensorNo := "cInSF0400", + stInOutSensor := "DB_Inputs".Sensors["cInSF0400"]); + // Not Halt Kanal 1 UZ0501 + #fbSensorInput(stInSensorHW := "SF0401", + nInSensorNo := "cInSF0401", + stInOutSensor := "DB_Inputs".Sensors["cInSF0401"]); + // Not Halt Kanal 1 UZ0502 + #fbSensorInput(stInSensorHW := "SF0402", + nInSensorNo := "cInSF0402", + stInOutSensor := "DB_Inputs".Sensors["cInSF0402"]); + // Not Halt Kanal 2 UH05 + #fbSensorInput(stInSensorHW := "SF0404", + nInSensorNo := "cInSF0404", + stInOutSensor := "DB_Inputs".Sensors["cInSF0404"]); + // Not Halt Kanal 2 UZ0501 + #fbSensorInput(stInSensorHW := "SF0405", + nInSensorNo := "cInSF0405", + stInOutSensor := "DB_Inputs".Sensors["cInSF0405"]); + // Not Halt Kanal 2 UZ0502 + #fbSensorInput(stInSensorHW := "SF0406", + nInSensorNo := "cInSF0406", + stInOutSensor := "DB_Inputs".Sensors["cInSF0406"]); + // Not Halt Kanal 1 UZ0504 + #fbSensorInput(stInSensorHW := "SF0470", + nInSensorNo := "cInSF0470", + stInOutSensor := "DB_Inputs".Sensors["cInSF0470"]); + // Not Halt Kanal 1 UZ0506 + #fbSensorInput(stInSensorHW := "SF0472", + nInSensorNo := "cInSF0472", + stInOutSensor := "DB_Inputs".Sensors["cInSF0472"]); + // Not Halt Kanal 1 UZ0507 + #fbSensorInput(stInSensorHW := "SF0473", + nInSensorNo := "cInSF0473", + stInOutSensor := "DB_Inputs".Sensors["cInSF0473"]); + // Not Halt Kanal 2 UZ0504 + #fbSensorInput(stInSensorHW := "SF0474", + nInSensorNo := "cInSF0474", + stInOutSensor := "DB_Inputs".Sensors["cInSF0474"]); + // Not Halt Kanal 2 UZ0506 + #fbSensorInput(stInSensorHW := "SF0476", + nInSensorNo := "cInSF0476", + stInOutSensor := "DB_Inputs".Sensors["cInSF0476"]); + // Not Halt Kanal 2 UZ0507 + #fbSensorInput(stInSensorHW := "SF0477", + nInSensorNo := "cInSF0477", + stInOutSensor := "DB_Inputs".Sensors["cInSF0477"]); + // Not Halt Schnittstelle von UH02 CH1 + #fbSensorInput(stInSensorHW := "SF0541", + nInSensorNo := "cInSF0541", + stInOutSensor := "DB_Inputs".Sensors["cInSF0541"]); + // Not Halt Schnittstelle von System Fortna C, CH1 + #fbSensorInput(stInSensorHW := "SF0542", + nInSensorNo := "cInSF0542", + stInOutSensor := "DB_Inputs".Sensors["cInSF0542"]); + // Not Halt Schnittstelle von UH07 CH1 + #fbSensorInput(stInSensorHW := "SF0543", + nInSensorNo := "cInSF0543", + stInOutSensor := "DB_Inputs".Sensors["cInSF0543"]); + // Not Halt Schnittstelle von UH02 CH2 + #fbSensorInput(stInSensorHW := "SF0545", + nInSensorNo := "cInSF0545", + stInOutSensor := "DB_Inputs".Sensors["cInSF0545"]); + // Not Halt Schnittstelle von System Fortna C, CH2 + #fbSensorInput(stInSensorHW := "SF0546", + nInSensorNo := "cInSF0546", + stInOutSensor := "DB_Inputs".Sensors["cInSF0546"]); + // Not Halt Schnittstelle von UH07 CH2 + #fbSensorInput(stInSensorHW := "SF0547", + nInSensorNo := "cInSF0547", + stInOutSensor := "DB_Inputs".Sensors["cInSF0547"]); + // in Separator (ILS KR-M5002) + #fbSensorInput(stInSensorHW := "BG3240", + nInSensorNo := "cInBG3240", + stInOutSensor := "DB_Inputs".Sensors["cInBG3240"]); + // Stausensor (ILS KR-M5002) + #fbSensorInput(stInSensorHW := "BG3241", + nInSensorNo := "cInBG3241", + stInOutSensor := "DB_Inputs".Sensors["cInBG3241"]); + // in Separator (ILS KR-M5002) + #fbSensorInput(stInSensorHW := "BG3242", + nInSensorNo := "cInBG3242", + stInOutSensor := "DB_Inputs".Sensors["cInBG3242"]); + // Staumelder, Einfahrt (ILS-CV-M5003) + #fbSensorInput(stInSensorHW := "BG3243", + nInSensorNo := "cInBG3243", + stInOutSensor := "DB_Inputs".Sensors["cInBG3243"]); + // Staumelder, Einfahrt (ILS-CV M5003) WS1.1 + #fbSensorInput(stInSensorHW := "BG3244", + nInSensorNo := "cInBG3244", + stInOutSensor := "DB_Inputs".Sensors["cInBG3244"]); + // in Separator 1 (ILS-CV M5003) WS1.1 + #fbSensorInput(stInSensorHW := "BG3245", + nInSensorNo := "cInBG3245", + stInOutSensor := "DB_Inputs".Sensors["cInBG3245"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M5003) WS1.1 + #fbSensorInput(stInSensorHW := "BG3246", + nInSensorNo := "cInBG3246", + stInOutSensor := "DB_Inputs".Sensors["cInBG3246"]); + // Sensor Förderer voll (ILS-CV M5003) WS1.1 + #fbSensorInput(stInSensorHW := "BG3247", + nInSensorNo := "cInBG3247", + stInOutSensor := "DB_Inputs".Sensors["cInBG3247"]); + // Stausensor (ILS-CV M5003) WS1.1 + #fbSensorInput(stInSensorHW := "BG3250", + nInSensorNo := "cInBG3250", + stInOutSensor := "DB_Inputs".Sensors["cInBG3250"]); + // in Separator 2 (ILS-CV M5004) WS1.1 + #fbSensorInput(stInSensorHW := "BG3251", + nInSensorNo := "cInBG3251", + stInOutSensor := "DB_Inputs".Sensors["cInBG3251"]); + // Staumelder, Einfahrt (ILS-CV M5004) WS1.1 + #fbSensorInput(stInSensorHW := "BG3252", + nInSensorNo := "cInBG3252", + stInOutSensor := "DB_Inputs".Sensors["cInBG3252"]); + // in Separator 3 (ILS-CV M5004) WS1.1 + #fbSensorInput(stInSensorHW := "BG3253", + nInSensorNo := "cInBG3253", + stInOutSensor := "DB_Inputs".Sensors["cInBG3253"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M5004) WS1.1 + #fbSensorInput(stInSensorHW := "BG3254", + nInSensorNo := "cInBG3254", + stInOutSensor := "DB_Inputs".Sensors["cInBG3254"]); + // MT in Position (ILS-CV M5004) WS1.1 + #fbSensorInput(stInSensorHW := "BG3255", + nInSensorNo := "cInBG3255", + stInOutSensor := "DB_Inputs".Sensors["cInBG3255"]); + // Sensor Förderer voll (ILS-CV M5004) WS1.1 + #fbSensorInput(stInSensorHW := "BG3256", + nInSensorNo := "cInBG3256", + stInOutSensor := "DB_Inputs".Sensors["cInBG3256"]); + // in Separator 4 (ILS-CV M5004) WS1.1 + #fbSensorInput(stInSensorHW := "BG3257", + nInSensorNo := "cInBG3257", + stInOutSensor := "DB_Inputs".Sensors["cInBG3257"]); + // Staumelder, Einfahrt (ILS-KR-M5002) + #fbSensorInput(stInSensorHW := "BG3260", + nInSensorNo := "cInBG3260", + stInOutSensor := "DB_Inputs".Sensors["cInBG3260"]); + // Stausensor (ILS KR-M5002) + #fbSensorInput(stInSensorHW := "BG3261", + nInSensorNo := "cInBG3261", + stInOutSensor := "DB_Inputs".Sensors["cInBG3261"]); + // Stausensor 1 (ILS-CV M5004) WS1.1 + #fbSensorInput(stInSensorHW := "BG3262", + nInSensorNo := "cInBG3262", + stInOutSensor := "DB_Inputs".Sensors["cInBG3262"]); + // Sensor Förderer voll (ILS CV-M5000) + #fbSensorInput(stInSensorHW := "BG3300", + nInSensorNo := "cInBG3300", + stInOutSensor := "DB_Inputs".Sensors["cInBG3300"]); + // in Separator (ILS CV-M5000) + #fbSensorInput(stInSensorHW := "BG3301", + nInSensorNo := "cInBG3301", + stInOutSensor := "DB_Inputs".Sensors["cInBG3301"]); + // Stausensor (ILS KR-M5002) + #fbSensorInput(stInSensorHW := "BG3302", + nInSensorNo := "cInBG3302", + stInOutSensor := "DB_Inputs".Sensors["cInBG3302"]); + // Sensor Förderer voll (ILS CV-M5001) + #fbSensorInput(stInSensorHW := "BG3303", + nInSensorNo := "cInBG3303", + stInOutSensor := "DB_Inputs".Sensors["cInBG3303"]); + // in Separator (ILS CV-M5001) + #fbSensorInput(stInSensorHW := "BG3304", + nInSensorNo := "cInBG3304", + stInOutSensor := "DB_Inputs".Sensors["cInBG3304"]); + // Stausensor (ILS CV-M5001) + #fbSensorInput(stInSensorHW := "BG3305", + nInSensorNo := "cInBG3305", + stInOutSensor := "DB_Inputs".Sensors["cInBG3305"]); + // in Separator (ILS KR-M5002) + #fbSensorInput(stInSensorHW := "BG3306", + nInSensorNo := "cInBG3306", + stInOutSensor := "DB_Inputs".Sensors["cInBG3306"]); + // in Separator (ILS CV-M5002) + #fbSensorInput(stInSensorHW := "BG3307", + nInSensorNo := "cInBG3307", + stInOutSensor := "DB_Inputs".Sensors["cInBG3307"]); + // Stausensor (ILS KR-M5000) + #fbSensorInput(stInSensorHW := "BG3310", + nInSensorNo := "cInBG3310", + stInOutSensor := "DB_Inputs".Sensors["cInBG3310"]); + // Stausensor 1 (ILS CV-M5000) + #fbSensorInput(stInSensorHW := "BG3311", + nInSensorNo := "cInBG3311", + stInOutSensor := "DB_Inputs".Sensors["cInBG3311"]); + // in Separator(ILS-KR-M5002) + #fbSensorInput(stInSensorHW := "BG3312", + nInSensorNo := "cInBG3312", + stInOutSensor := "DB_Inputs".Sensors["cInBG3312"]); + // Staumelder, Einfahrt (ILS-CV M5005) + #fbSensorInput(stInSensorHW := "BG3313", + nInSensorNo := "cInBG3313", + stInOutSensor := "DB_Inputs".Sensors["cInBG3313"]); + // in Separator (ILS-CV M5005) WS 1.0 + #fbSensorInput(stInSensorHW := "BG3314", + nInSensorNo := "cInBG3314", + stInOutSensor := "DB_Inputs".Sensors["cInBG3314"]); + // Staumelder, Einfahrt (ILS-CV M5005) WS 1.0 + #fbSensorInput(stInSensorHW := "BG3315", + nInSensorNo := "cInBG3315", + stInOutSensor := "DB_Inputs".Sensors["cInBG3315"]); + // in Separator 3 (ILS-CV M5005) WS 1.0 + #fbSensorInput(stInSensorHW := "BG3316", + nInSensorNo := "cInBG3316", + stInOutSensor := "DB_Inputs".Sensors["cInBG3316"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M5005) WS 1.0 + #fbSensorInput(stInSensorHW := "BG3317", + nInSensorNo := "cInBG3317", + stInOutSensor := "DB_Inputs".Sensors["cInBG3317"]); + // MT in Position (ILS-CV M5005) WS 1.0 + #fbSensorInput(stInSensorHW := "BG3320", + nInSensorNo := "cInBG3320", + stInOutSensor := "DB_Inputs".Sensors["cInBG3320"]); + // Sensor Förderer voll (ILS-CV M5005) WS 1.0 + #fbSensorInput(stInSensorHW := "BG3321", + nInSensorNo := "cInBG3321", + stInOutSensor := "DB_Inputs".Sensors["cInBG3321"]); + // in Separator (ILS-CV M5005) WS 1.0 + #fbSensorInput(stInSensorHW := "BG3322", + nInSensorNo := "cInBG3322", + stInOutSensor := "DB_Inputs".Sensors["cInBG3322"]); + // Staumelder, Einfahrt (ILS-KR M5002) + #fbSensorInput(stInSensorHW := "BG3323", + nInSensorNo := "cInBG3323", + stInOutSensor := "DB_Inputs".Sensors["cInBG3323"]); + // Stausensor (ILS KR-M5002) + #fbSensorInput(stInSensorHW := "BG3324", + nInSensorNo := "cInBG3324", + stInOutSensor := "DB_Inputs".Sensors["cInBG3324"]); + // Stausensor 1 (ILS CV-M5001) + #fbSensorInput(stInSensorHW := "BG3325", + nInSensorNo := "cInBG3325", + stInOutSensor := "DB_Inputs".Sensors["cInBG3325"]); + // Stausensor (ILS-CV M5005) WS 1.0 + #fbSensorInput(stInSensorHW := "BG3326", + nInSensorNo := "cInBG3326", + stInOutSensor := "DB_Inputs".Sensors["cInBG3326"]); + // Teil auf MT (Sep 5MB3307) + #fbSensorInput(stInSensorHW := "BG3327", + nInSensorNo := "cInBG3327", + stInOutSensor := "DB_Inputs".Sensors["cInBG3327"]); + // in Separator (ILS-CV M0510) + #fbSensorInput(stInSensorHW := "BG3330", + nInSensorNo := "cInBG3330", + stInOutSensor := "DB_Inputs".Sensors["cInBG3330"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M5000_A) + #fbSensorInput(stInSensorHW := "BG3331", + nInSensorNo := "cInBG3331", + stInOutSensor := "DB_Inputs".Sensors["cInBG3331"]); + // MT in Position (ILS-CV M5000_A) + #fbSensorInput(stInSensorHW := "BG3332", + nInSensorNo := "cInBG3332", + stInOutSensor := "DB_Inputs".Sensors["cInBG3332"]); + // in Separator (ILS-CV M5001_A) + #fbSensorInput(stInSensorHW := "BG3333", + nInSensorNo := "cInBG3333", + stInOutSensor := "DB_Inputs".Sensors["cInBG3333"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M5001_A) + #fbSensorInput(stInSensorHW := "BG3334", + nInSensorNo := "cInBG3334", + stInOutSensor := "DB_Inputs".Sensors["cInBG3334"]); + // MT in Position (ILS-CV M5001_A) + #fbSensorInput(stInSensorHW := "BG3335", + nInSensorNo := "cInBG3335", + stInOutSensor := "DB_Inputs".Sensors["cInBG3335"]); + // in Separator(ILS-KR-M5002) + #fbSensorInput(stInSensorHW := "BG3360", + nInSensorNo := "cInBG3360", + stInOutSensor := "DB_Inputs".Sensors["cInBG3360"]); + // Staumelder, Einfahrt (ILS-CV M5006) + #fbSensorInput(stInSensorHW := "BG3361", + nInSensorNo := "cInBG3361", + stInOutSensor := "DB_Inputs".Sensors["cInBG3361"]); + // in Separator (ILS-CV M5006) WS 2.0 + #fbSensorInput(stInSensorHW := "BG3362", + nInSensorNo := "cInBG3362", + stInOutSensor := "DB_Inputs".Sensors["cInBG3362"]); + // Staumelder, Einfahrt (ILS-CV M5006) WS 2.0 + #fbSensorInput(stInSensorHW := "BG3363", + nInSensorNo := "cInBG3363", + stInOutSensor := "DB_Inputs".Sensors["cInBG3363"]); + // in Separator 3 (ILS-CV M5006) WS 2.0 + #fbSensorInput(stInSensorHW := "BG3364", + nInSensorNo := "cInBG3364", + stInOutSensor := "DB_Inputs".Sensors["cInBG3364"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M5006) WS 2.0 + #fbSensorInput(stInSensorHW := "BG3365", + nInSensorNo := "cInBG3365", + stInOutSensor := "DB_Inputs".Sensors["cInBG3365"]); + // MT in Position (ILS-CV M5006) WS 2.0 + #fbSensorInput(stInSensorHW := "BG3366", + nInSensorNo := "cInBG3366", + stInOutSensor := "DB_Inputs".Sensors["cInBG3366"]); + // Sensor Förderer voll (ILS-CV M5006) WS 2.0 + #fbSensorInput(stInSensorHW := "BG3367", + nInSensorNo := "cInBG3367", + stInOutSensor := "DB_Inputs".Sensors["cInBG3367"]); + // in Separator (ILS-CV M5006) WS 2.0 + #fbSensorInput(stInSensorHW := "BG3370", + nInSensorNo := "cInBG3370", + stInOutSensor := "DB_Inputs".Sensors["cInBG3370"]); + // Staumelder, Einfahrt (ILS-KR M5002) + #fbSensorInput(stInSensorHW := "BG3371", + nInSensorNo := "cInBG3371", + stInOutSensor := "DB_Inputs".Sensors["cInBG3371"]); + // in Separator(ILS-KR-M0500) + #fbSensorInput(stInSensorHW := "BG3372", + nInSensorNo := "cInBG3372", + stInOutSensor := "DB_Inputs".Sensors["cInBG3372"]); + // Staumelder, Einfahrt (ILS-CV M5007 + #fbSensorInput(stInSensorHW := "BG3373", + nInSensorNo := "cInBG3373", + stInOutSensor := "DB_Inputs".Sensors["cInBG3373"]); + // in Separator (ILS-CV M5007) WS 3.0 + #fbSensorInput(stInSensorHW := "BG3374", + nInSensorNo := "cInBG3374", + stInOutSensor := "DB_Inputs".Sensors["cInBG3374"]); + // Staumelder, Einfahrt (ILS-CV M5007) WS 3.0 + #fbSensorInput(stInSensorHW := "BG3375", + nInSensorNo := "cInBG3375", + stInOutSensor := "DB_Inputs".Sensors["cInBG3375"]); + // in Separator 3 (ILS-CV M5007) WS 3.0 + #fbSensorInput(stInSensorHW := "BG3376", + nInSensorNo := "cInBG3376", + stInOutSensor := "DB_Inputs".Sensors["cInBG3376"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M5007) WS 3.0 + #fbSensorInput(stInSensorHW := "BG3377", + nInSensorNo := "cInBG3377", + stInOutSensor := "DB_Inputs".Sensors["cInBG3377"]); + // MT in Position (ILS-CV M5007) WS 3.0 + #fbSensorInput(stInSensorHW := "BG3380", + nInSensorNo := "cInBG3380", + stInOutSensor := "DB_Inputs".Sensors["cInBG3380"]); + // Sensor Förderer voll (ILS-CV M5007) WS 3.0 + #fbSensorInput(stInSensorHW := "BG3381", + nInSensorNo := "cInBG3381", + stInOutSensor := "DB_Inputs".Sensors["cInBG3381"]); + // in Separator (ILS-CV M5007) WS 3.0 + #fbSensorInput(stInSensorHW := "BG3382", + nInSensorNo := "cInBG3382", + stInOutSensor := "DB_Inputs".Sensors["cInBG3382"]); + // Staumelder, Einfahrt (ILS-KR M5002) + #fbSensorInput(stInSensorHW := "BG3383", + nInSensorNo := "cInBG3383", + stInOutSensor := "DB_Inputs".Sensors["cInBG3383"]); + // Stausensor (ILS KR-M5002) + #fbSensorInput(stInSensorHW := "BG3384", + nInSensorNo := "cInBG3384", + stInOutSensor := "DB_Inputs".Sensors["cInBG3384"]); + // Stausensor (ILS KR-M5002) + #fbSensorInput(stInSensorHW := "BG3385", + nInSensorNo := "cInBG3385", + stInOutSensor := "DB_Inputs".Sensors["cInBG3385"]); + // Stausensor (ILS-CV M5006) WS 2.0 + #fbSensorInput(stInSensorHW := "BG3386", + nInSensorNo := "cInBG3386", + stInOutSensor := "DB_Inputs".Sensors["cInBG3386"]); + // Stausensor (ILS-CV M5007) WS 3.0 + #fbSensorInput(stInSensorHW := "BG3387", + nInSensorNo := "cInBG3387", + stInOutSensor := "DB_Inputs".Sensors["cInBG3387"]); + // in Separator(ILS-KR-M5002) + #fbSensorInput(stInSensorHW := "BG3420", + nInSensorNo := "cInBG3420", + stInOutSensor := "DB_Inputs".Sensors["cInBG3420"]); + // Staumelder, Einfahrt (ILS-CV M5008) + #fbSensorInput(stInSensorHW := "BG3421", + nInSensorNo := "cInBG3421", + stInOutSensor := "DB_Inputs".Sensors["cInBG3421"]); + // in Separator (ILS-CV M5008) WS 4.0 + #fbSensorInput(stInSensorHW := "BG3422", + nInSensorNo := "cInBG3422", + stInOutSensor := "DB_Inputs".Sensors["cInBG3422"]); + // Staumelder, Einfahrt (ILS-CV M5008) WS 4.0 + #fbSensorInput(stInSensorHW := "BG3423", + nInSensorNo := "cInBG3423", + stInOutSensor := "DB_Inputs".Sensors["cInBG3423"]); + // in Separator (ILS-CV M5008) WS 4.0 + #fbSensorInput(stInSensorHW := "BG3424", + nInSensorNo := "cInBG3424", + stInOutSensor := "DB_Inputs".Sensors["cInBG3424"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M5008) WS 4.0 + #fbSensorInput(stInSensorHW := "BG3425", + nInSensorNo := "cInBG3425", + stInOutSensor := "DB_Inputs".Sensors["cInBG3425"]); + // MT in Position (ILS-CV M5008) WS 4.0 + #fbSensorInput(stInSensorHW := "BG3426", + nInSensorNo := "cInBG3426", + stInOutSensor := "DB_Inputs".Sensors["cInBG3426"]); + // Sensor Förderer voll (ILS-CV M5008) WS 4.0 + #fbSensorInput(stInSensorHW := "BG3427", + nInSensorNo := "cInBG3427", + stInOutSensor := "DB_Inputs".Sensors["cInBG3427"]); + // in Separator (ILS-CV M5008) WS 4.0 + #fbSensorInput(stInSensorHW := "BG3430", + nInSensorNo := "cInBG3430", + stInOutSensor := "DB_Inputs".Sensors["cInBG3430"]); + // Staumelder, Einfahrt (ILS-KR M0500) + #fbSensorInput(stInSensorHW := "BG3431", + nInSensorNo := "cInBG3431", + stInOutSensor := "DB_Inputs".Sensors["cInBG3431"]); + // in Separator(ILS-KR-M5002) + #fbSensorInput(stInSensorHW := "BG3432", + nInSensorNo := "cInBG3432", + stInOutSensor := "DB_Inputs".Sensors["cInBG3432"]); + // in Separator(ILS-KR-M5002) + #fbSensorInput(stInSensorHW := "BG3433", + nInSensorNo := "cInBG3433", + stInOutSensor := "DB_Inputs".Sensors["cInBG3433"]); + // Stausensor (ILS-KR M5002) + #fbSensorInput(stInSensorHW := "BG3434", + nInSensorNo := "cInBG3434", + stInOutSensor := "DB_Inputs".Sensors["cInBG3434"]); + // Rad dreht (ILS-CV KR-M5002) + #fbSensorInput(stInSensorHW := "BG3435", + nInSensorNo := "cInBG3435", + stInOutSensor := "DB_Inputs".Sensors["cInBG3435"]); + // Staumelder, Einfahrt (ILS-CV M2111) + #fbSensorInput(stInSensorHW := "BG3436", + nInSensorNo := "cInBG3436", + stInOutSensor := "DB_Inputs".Sensors["cInBG3436"]); + // Stausensor (ILS KR-M5002) + #fbSensorInput(stInSensorHW := "BG3437", + nInSensorNo := "cInBG3437", + stInOutSensor := "DB_Inputs".Sensors["cInBG3437"]); + // Längenabfrage Grenze kurz (ILS-CV) + #fbSensorInput(stInSensorHW := "BG3440", + nInSensorNo := "cInBG3440", + stInOutSensor := "DB_Inputs".Sensors["cInBG3440"]); + // Längenabfrage Grenze lang (ILS-CV) + #fbSensorInput(stInSensorHW := "BG3441", + nInSensorNo := "cInBG3441", + stInOutSensor := "DB_Inputs".Sensors["cInBG3441"]); + // Längenabfrage Grenze zu lang (ILS-CV) + #fbSensorInput(stInSensorHW := "BG3442", + nInSensorNo := "cInBG3442", + stInOutSensor := "DB_Inputs".Sensors["cInBG3442"]); + // Verlassensensor Längenmessung (ILS-CV) + #fbSensorInput(stInSensorHW := "BG3443", + nInSensorNo := "cInBG3443", + stInOutSensor := "DB_Inputs".Sensors["cInBG3443"]); + // Stausensor (ILS-CV M5008) WS 4.0 + #fbSensorInput(stInSensorHW := "BG3444", + nInSensorNo := "cInBG3444", + stInOutSensor := "DB_Inputs".Sensors["cInBG3444"]); + // Sensor Förderer voll (ILS CV-M5000_A) + #fbSensorInput(stInSensorHW := "BG3450", + nInSensorNo := "cInBG3450", + stInOutSensor := "DB_Inputs".Sensors["cInBG3450"]); + // Stausensor (ILS CV-M5000_A) + #fbSensorInput(stInSensorHW := "BG3451", + nInSensorNo := "cInBG3451", + stInOutSensor := "DB_Inputs".Sensors["cInBG3451"]); + // in Separator (ILS CV-M5000_B) + #fbSensorInput(stInSensorHW := "BG3452", + nInSensorNo := "cInBG3452", + stInOutSensor := "DB_Inputs".Sensors["cInBG3452"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M5000_B) + #fbSensorInput(stInSensorHW := "BG3453", + nInSensorNo := "cInBG3453", + stInOutSensor := "DB_Inputs".Sensors["cInBG3453"]); + // MT in Position (ILS-CV M5000_B) + #fbSensorInput(stInSensorHW := "BG3454", + nInSensorNo := "cInBG3454", + stInOutSensor := "DB_Inputs".Sensors["cInBG3454"]); + // Sensor Förderer voll (ILS CV-M5001_A) + #fbSensorInput(stInSensorHW := "BG3455", + nInSensorNo := "cInBG3455", + stInOutSensor := "DB_Inputs".Sensors["cInBG3455"]); + // Stausensor (ILS CV-M5001_A) + #fbSensorInput(stInSensorHW := "BG3456", + nInSensorNo := "cInBG3456", + stInOutSensor := "DB_Inputs".Sensors["cInBG3456"]); + // in Separator (ILS CV-M5001_B) + #fbSensorInput(stInSensorHW := "BG3457", + nInSensorNo := "cInBG3457", + stInOutSensor := "DB_Inputs".Sensors["cInBG3457"]); + // Abfrage Mitnehmerfinger in Position (ILS-CV M5001_B) + #fbSensorInput(stInSensorHW := "BG3460", + nInSensorNo := "cInBG3460", + stInOutSensor := "DB_Inputs".Sensors["cInBG3460"]); + // MT in Position (ILS-CV M5001_B) + #fbSensorInput(stInSensorHW := "BG3461", + nInSensorNo := "cInBG3461", + stInOutSensor := "DB_Inputs".Sensors["cInBG3461"]); +END_FUNCTION_BLOCK diff --git a/results/FB_Main_skel_UH01.scl b/results/FB_Main_skel_UH01.scl new file mode 100644 index 0000000..8f27fcb --- /dev/null +++ b/results/FB_Main_skel_UH01.scl @@ -0,0 +1,582 @@ +FUNCTION_BLOCK "FB_Main_skel_UH01" +{ S7_Optimized_Access := 'TRUE' } +VERSION : 0.1 +// ============================================================ +// AUTOMATISCH GENERIERTES GRUNDGERUEST — create_skel.py +// Quelle: E/A-Listen UH01 (data/) +// TODO-Marken kennzeichnen manuell zu ergaenzende Stellen +// (Timings, Topologie/JamAreas, Safety, Release, Priority). +// ============================================================ + VAR + TRO101 : "FB_ILS_MTRO_Vario"; // CV-M0100 + TRO102 : "FB_ILS_MTRO_1Sep"; // KR-M0101 / LS2 + TRO103 : "FB_ILS_MTRO_1Sep1Swi"; // KR-M0102 + TRO104 : "FB_ILS_MTRO_Vario"; // CV-M0103 + fbConveyor0105 : "FB_Conveyor"; // CV-M0105 + TRO106 : "FB_ILS_MTRO_Vario"; // CV-M0106 + TRO107 : "FB_ILS_MTRO_Vario"; // CV-M0107 + fbConveyor0109 : "FB_Conveyor"; // CV-M0109 + TRO109 : "FB_ILS_MTRO_Vario"; // CV-M0110 + fbConveyor4103 : "FB_Conveyor"; // CV-M4103 + TRO111 : "FB_ILS_MTRO_Vario"; // CV-M4103_A + fbConveyor4103_B : "FB_Conveyor"; // CV-M4103_B + TRO113 : "FB_ILS_MTRO_Vario"; // CV-M4104 + TRO114 : "FB_ILS_MTRO_1Sep"; // CV-M4203 + TRO115 : "FB_ILS_MTRO_Vario"; // CV-M4203_A + fbConveyor4203_B : "FB_Conveyor"; // CV-M4203_B + TRO117 : "FB_ILS_MTRO_1Sep1Swi"; // KR-M4204 + TRO118 : "FB_ILS_MTRO_1Sep"; // CV-M4302 + TRO119 : "FB_ILS_MTRO_Vario"; // CV-M4302_A + TRO120 : "FB_ILS_MTRO_Vario"; // CV-M4302_B + fbConveyor4402_A : "FB_Conveyor"; // CV-M4402_A + TRO122 : "FB_ILS_MTRO_Vario"; // CV-M4402_B + TRO123 : "FB_ILS_MTRO_Vario"; // CV-M4403 + TRO124 : "FB_ILS_MTRO_Vario"; // CV-M4501 + TRO125 : "FB_ILS_MTRO_Vario"; // CV-M4502 + TRO126 : "FB_ILS_MTRO_Vario"; // CV-M4503 + fbConveyorM0103 : "FB_Conveyor"; // CV-PM0103 + END_VAR + +BEGIN + REGION TRO101 (Vario) — CV-M0100 + #TRO101.stInSeparator1.Settings.nSeparatorNo := "cSep101.1"; + #TRO101.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO101.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3242"]; + #TRO101.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3292"]; + #TRO101.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3291"]; + #TRO101.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3241"]; + + #TRO101(nInMainTroNo := "cMainTro101", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea101".stJam101_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea101".stJam101_1.stData, + arInOutJamFinger := "DB_JamArea101".stJam101_2.arCarrier, // TODO Topologie + xOutStopper => "MB3290", + xOutVarioMotor => "MA0057", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro101"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO101); + END_REGION + + REGION TRO102 (1Sep) — KR-M0101 / LS2 + #TRO102.stInSeparator1.Settings.nSeparatorNo := "cSep102.1"; + #TRO102.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO102.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO102.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO102.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO102.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3246"]; + #TRO102.stInSenJam2 := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO102.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO102(nInMainTroNo := "cMainTro102", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea102".stJam102_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea102".stJam102_1.stData, + arInOutJamExit2 := "DB_JamArea102".stJam102_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea102".stJam102_2.stData, + xOutStopper1 => "MB3246", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro102"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO102); + END_REGION + + REGION TRO103 (1Sep1Swi) — KR-M0102 + #TRO103.stInSeparator1.Settings.nSeparatorNo := "cSep103.1"; + #TRO103.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO103.stInSeparator1.Settings.tTrailingTime := T#100ms; // TODO Timing + #TRO103.stInSeparator1.Settings.tHandlingTime := T#50ms; // TODO Timing + #TRO103.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO103.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3300"]; + #TRO103.stInSenJam2 := "DB_Inputs".Sensors["cInBG3304"]; + #TRO103.stInSwitch1.Settings.nSwitchNo := "cSwi103.1"; + + #TRO103(nInMainTroNo := "cMainTro103", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun1 := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea103".stJam103_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea103".stJam103_1.stData, + arInOutJamExit2 := "DB_JamArea103".stJam103_2.arCarrier, // TODO Topologie (Dir1) + stInOutJamExit2 := "DB_JamArea103".stJam103_2.stData, + arInOutJamExit3 := "DB_JamArea103".stJam103_3.arCarrier, // TODO Topologie (Dir2) + stInOutJamExit3 := "DB_JamArea103".stJam103_3.stData, + xOutStopper1 => "MB3300", + xOutSw1ExTo3 => "MB3304", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro103"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO103); + END_REGION + + REGION TRO104 (Vario) — CV-M0103 + #TRO104.stInSeparator1.Settings.nSeparatorNo := "cSep104.1"; + #TRO104.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO104.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3271"]; + #TRO104.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3272"]; + #TRO104.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3270"]; + #TRO104.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3305"]; + + #TRO104(nInMainTroNo := "cMainTro104", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea104".stJam104_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea104".stJam104_1.stData, + arInOutJamFinger := "DB_JamArea104".stJam104_2.arCarrier, // TODO Topologie + xOutStopper => "MB3271", + xOutVarioMotor => "MAxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro104"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO104); + END_REGION + + REGION fbConveyor0105 — CV-M0105 + #fbConveyor0105.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor0105.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor0105.Settings.sMotorProtectName := 'FC0063'; + + #fbConveyor0105(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0063", + xInPowerContactor := "MAxxxx", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor0105); + END_REGION + + REGION TRO106 (Vario) — CV-M0106 + #TRO106.stInSeparator1.Settings.nSeparatorNo := "cSep106.1"; + #TRO106.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO106.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO106.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO106.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3273"]; + #TRO106.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3276"]; + + #TRO106(nInMainTroNo := "cMainTro106", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea106".stJam106_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea106".stJam106_1.stData, + arInOutJamFinger := "DB_JamArea106".stJam106_2.arCarrier, // TODO Topologie + xOutStopper => "MBxxxx", + xOutVarioMotor => "MA0064", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro106"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO106); + END_REGION + + REGION TRO107 (Vario) — CV-M0107 + #TRO107.stInSeparator1.Settings.nSeparatorNo := "cSep107.1"; + #TRO107.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO107.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3283"]; + #TRO107.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3282"]; + #TRO107.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3284"]; + #TRO107.stInVario.stSenJam := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO107(nInMainTroNo := "cMainTro107", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea107".stJam107_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea107".stJam107_1.stData, + arInOutJamFinger := "DB_JamArea107".stJam107_2.arCarrier, // TODO Topologie + xOutStopper => "MB3283", + xOutVarioMotor => "MA0065", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro107"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO107); + END_REGION + + REGION fbConveyor0109 — CV-M0109 + #fbConveyor0109.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor0109.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor0109.Settings.sMotorProtectName := 'FC0066'; + + #fbConveyor0109(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0066", + xInPowerContactor := "MAxxxx", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor0109); + END_REGION + + REGION TRO109 (Vario) — CV-M0110 + #TRO109.stInSeparator1.Settings.nSeparatorNo := "cSep109.1"; + #TRO109.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO109.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO109.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO109.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3285"]; + #TRO109.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3294"]; + + #TRO109(nInMainTroNo := "cMainTro109", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea109".stJam109_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea109".stJam109_1.stData, + arInOutJamFinger := "DB_JamArea109".stJam109_2.arCarrier, // TODO Topologie + xOutStopper => "MBxxxx", + xOutVarioMotor => "MA0067", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro109"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO109); + END_REGION + + REGION fbConveyor4103 — CV-M4103 + #fbConveyor4103.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor4103.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor4103.Settings.sMotorProtectName := 'FC0146'; + + #fbConveyor4103(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0146", + xInPowerContactor := "MAxxxx", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor4103); + END_REGION + + REGION TRO111 (Vario) — CV-M4103_A + #TRO111.stInSeparator1.Settings.nSeparatorNo := "cSep111.1"; + #TRO111.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO111.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3003"]; + #TRO111.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3004"]; + #TRO111.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3002"]; + #TRO111.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3005"]; + + #TRO111(nInMainTroNo := "cMainTro111", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea111".stJam111_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea111".stJam111_1.stData, + arInOutJamFinger := "DB_JamArea111".stJam111_2.arCarrier, // TODO Topologie + xOutStopper => "MB3003", + xOutVarioMotor => "MA0146", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro111"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO111); + END_REGION + + REGION fbConveyor4103_B — CV-M4103_B + #fbConveyor4103_B.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor4103_B.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor4103_B.Settings.sMotorProtectName := 'FC0152'; + + #fbConveyor4103_B(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0152", + xInPowerContactor := "MA0152", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor4103_B); + END_REGION + + REGION TRO113 (Vario) — CV-M4104 + #TRO113.stInSeparator1.Settings.nSeparatorNo := "cSep113.1"; + #TRO113.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO113.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3025"]; + #TRO113.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3026"]; + #TRO113.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3027"]; + #TRO113.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3001"]; + + #TRO113(nInMainTroNo := "cMainTro113", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea113".stJam113_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea113".stJam113_1.stData, + arInOutJamFinger := "DB_JamArea113".stJam113_2.arCarrier, // TODO Topologie + xOutStopper => "MB3025", + xOutVarioMotor => "MA0145", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro113"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO113); + END_REGION + + REGION TRO114 (1Sep) — CV-M4203 + #TRO114.stInSeparator1.Settings.nSeparatorNo := "cSep114.1"; + #TRO114.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO114.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO114.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO114.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO114.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3024"]; + #TRO114.stInSenJam2 := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO114.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO114(nInMainTroNo := "cMainTro114", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea114".stJam114_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea114".stJam114_1.stData, + arInOutJamExit2 := "DB_JamArea114".stJam114_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea114".stJam114_2.stData, + xOutStopper1 => "MB3024", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro114"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO114); + END_REGION + + REGION TRO115 (Vario) — CV-M4203_A + #TRO115.stInSeparator1.Settings.nSeparatorNo := "cSep115.1"; + #TRO115.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO115.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3120"]; + #TRO115.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3121"]; + #TRO115.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO115.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3124"]; + + #TRO115(nInMainTroNo := "cMainTro115", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea115".stJam115_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea115".stJam115_1.stData, + arInOutJamFinger := "DB_JamArea115".stJam115_2.arCarrier, // TODO Topologie + xOutStopper => "MB3120", + xOutVarioMotor => "MA0147", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro115"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO115); + END_REGION + + REGION fbConveyor4203_B — CV-M4203_B + #fbConveyor4203_B.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor4203_B.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor4203_B.Settings.sMotorProtectName := 'FC0153'; + + #fbConveyor4203_B(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0153", + xInPowerContactor := "MA0153", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor4203_B); + END_REGION + + REGION TRO117 (1Sep1Swi) — KR-M4204 + #TRO117.stInSeparator1.Settings.nSeparatorNo := "cSep117.1"; + #TRO117.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO117.stInSeparator1.Settings.tTrailingTime := T#100ms; // TODO Timing + #TRO117.stInSeparator1.Settings.tHandlingTime := T#50ms; // TODO Timing + #TRO117.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO117.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3010"]; + #TRO117.stInSenJam2 := "DB_Inputs".Sensors["cInBG3012"]; + #TRO117.stInSwitch1.Settings.nSwitchNo := "cSwi117.1"; + + #TRO117(nInMainTroNo := "cMainTro117", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun1 := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea117".stJam117_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea117".stJam117_1.stData, + arInOutJamExit2 := "DB_JamArea117".stJam117_2.arCarrier, // TODO Topologie (Dir1) + stInOutJamExit2 := "DB_JamArea117".stJam117_2.stData, + arInOutJamExit3 := "DB_JamArea117".stJam117_3.arCarrier, // TODO Topologie (Dir2) + stInOutJamExit3 := "DB_JamArea117".stJam117_3.stData, + xOutStopper1 => "MB3010", + xOutSw1ExTo3 => "MB3015", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro117"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO117); + END_REGION + + REGION TRO118 (1Sep) — CV-M4302 + #TRO118.stInSeparator1.Settings.nSeparatorNo := "cSep118.1"; + #TRO118.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO118.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO118.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO118.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO118.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3125"]; + #TRO118.stInSenJam2 := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO118.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO118(nInMainTroNo := "cMainTro118", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea118".stJam118_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea118".stJam118_1.stData, + arInOutJamExit2 := "DB_JamArea118".stJam118_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea118".stJam118_2.stData, + xOutStopper1 => "MB3125", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro118"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO118); + END_REGION + + REGION TRO119 (Vario) — CV-M4302_A + #TRO119.stInSeparator1.Settings.nSeparatorNo := "cSep119.1"; + #TRO119.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO119.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO119.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO119.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3122"]; + #TRO119.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3150"]; + + #TRO119(nInMainTroNo := "cMainTro119", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea119".stJam119_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea119".stJam119_1.stData, + arInOutJamFinger := "DB_JamArea119".stJam119_2.arCarrier, // TODO Topologie + xOutStopper => "MBxxxx", + xOutVarioMotor => "MA0154", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro119"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO119); + END_REGION + + REGION TRO120 (Vario) — CV-M4302_B + #TRO120.stInSeparator1.Settings.nSeparatorNo := "cSep120.1"; + #TRO120.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO120.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3130"]; + #TRO120.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3131"]; + #TRO120.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3132"]; + #TRO120.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3126"]; + + #TRO120(nInMainTroNo := "cMainTro120", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea120".stJam120_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea120".stJam120_1.stData, + arInOutJamFinger := "DB_JamArea120".stJam120_2.arCarrier, // TODO Topologie + xOutStopper => "MB3130", + xOutVarioMotor => "MA0150", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro120"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO120); + END_REGION + + REGION fbConveyor4402_A — CV-M4402_A + #fbConveyor4402_A.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor4402_A.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor4402_A.Settings.sMotorProtectName := 'FC0155'; + + #fbConveyor4402_A(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0155", + xInPowerContactor := "MA0155", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor4402_A); + END_REGION + + REGION TRO122 (Vario) — CV-M4402_B + #TRO122.stInSeparator1.Settings.nSeparatorNo := "cSep122.1"; + #TRO122.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO122.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3135"]; + #TRO122.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3136"]; + #TRO122.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3137"]; + #TRO122.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3134"]; + + #TRO122(nInMainTroNo := "cMainTro122", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea122".stJam122_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea122".stJam122_1.stData, + arInOutJamFinger := "DB_JamArea122".stJam122_2.arCarrier, // TODO Topologie + xOutStopper => "MB3135", + xOutVarioMotor => "MA0151", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro122"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO122); + END_REGION + + REGION TRO123 (Vario) — CV-M4403 + #TRO123.stInSeparator1.Settings.nSeparatorNo := "cSep123.1"; + #TRO123.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO123.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3073"]; + #TRO123.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3074"]; + #TRO123.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3075"]; + #TRO123.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3071"]; + + #TRO123(nInMainTroNo := "cMainTro123", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea123".stJam123_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea123".stJam123_1.stData, + arInOutJamFinger := "DB_JamArea123".stJam123_2.arCarrier, // TODO Topologie + xOutStopper => "MB3073", + xOutVarioMotor => "MA0143", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro123"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO123); + END_REGION + + REGION TRO124 (Vario) — CV-M4501 + #TRO124.stInSeparator1.Settings.nSeparatorNo := "cSep124.1"; + #TRO124.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO124.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3020"]; + #TRO124.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3011"]; + #TRO124.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3021"]; + #TRO124.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3017"]; + + #TRO124(nInMainTroNo := "cMainTro124", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea124".stJam124_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea124".stJam124_1.stData, + arInOutJamFinger := "DB_JamArea124".stJam124_2.arCarrier, // TODO Topologie + xOutStopper => "MB3020", + xOutVarioMotor => "MA0144", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro124"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO124); + END_REGION + + REGION TRO125 (Vario) — CV-M4502 + #TRO125.stInSeparator1.Settings.nSeparatorNo := "cSep125.1"; + #TRO125.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO125.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3063"]; + #TRO125.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3064"]; + #TRO125.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3065"]; + #TRO125.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3067"]; + + #TRO125(nInMainTroNo := "cMainTro125", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea125".stJam125_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea125".stJam125_1.stData, + arInOutJamFinger := "DB_JamArea125".stJam125_2.arCarrier, // TODO Topologie + xOutStopper => "MB3063", + xOutVarioMotor => "MA0142", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro125"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO125); + END_REGION + + REGION TRO126 (Vario) — CV-M4503 + #TRO126.stInSeparator1.Settings.nSeparatorNo := "cSep126.1"; + #TRO126.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO126.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3060"]; + #TRO126.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3082"]; + #TRO126.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3081"]; + #TRO126.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3061"]; + + #TRO126(nInMainTroNo := "cMainTro126", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea126".stJam126_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea126".stJam126_1.stData, + arInOutJamFinger := "DB_JamArea126".stJam126_2.arCarrier, // TODO Topologie + xOutStopper => "MB3060", + xOutVarioMotor => "MA0141", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro126"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO126); + END_REGION + + REGION fbConveyorM0103 — CV-PM0103 + #fbConveyorM0103.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyorM0103.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyorM0103.Settings.sMotorProtectName := 'FCxxxx'; + + #fbConveyorM0103(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FCxxxx", + xInPowerContactor := "MA0062", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyorM0103); + END_REGION + +END_FUNCTION_BLOCK diff --git a/results/FB_Main_skel_UH02.scl b/results/FB_Main_skel_UH02.scl new file mode 100644 index 0000000..94543d5 --- /dev/null +++ b/results/FB_Main_skel_UH02.scl @@ -0,0 +1,988 @@ +FUNCTION_BLOCK "FB_Main_skel_UH02" +{ S7_Optimized_Access := 'TRUE' } +VERSION : 0.1 +// ============================================================ +// AUTOMATISCH GENERIERTES GRUNDGERUEST — create_skel.py +// Quelle: E/A-Listen UH02 (data/) +// TODO-Marken kennzeichnen manuell zu ergaenzende Stellen +// (Timings, Topologie/JamAreas, Safety, Release, Priority). +// ============================================================ + VAR + TRO201 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K1101 / Block 1.1.1 + TRO202 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K1102 / Block 1.1.3 + TRO203 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K1201 / Block 1.2.1 + TRO204 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K1202 / Block 1.2.3 + TRO205 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K1303 / Block 1.3.1 + TRO206 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K1304 / Block 1.3.3 + TRO207 : "FB_ILS_MTRO_1Sep"; // KR-M1100 + TRO208 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M1101 / Block 1.1.1 + TRO209 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M1102 / Block 1.1.3 + TRO210 : "FB_ILS_MTRO_1Sep"; // KR-M1103 + TRO211 : "FB_ILS_MTRO_1Sep"; // CV-M1104 + TRO212 : "FB_ILS_MTRO_Vario"; // CV-M1105 + TRO213 : "FB_ILS_MTRO_Vario"; // CV-M1106 / Block 1.1.2 + TRO214 : "FB_ILS_MTRO_Vario"; // CV-M1107 + TRO215 : "FB_ILS_MTRO_Vario"; // CV-M1108 / Block 1.1.4 + TRO216 : "FB_ILS_MTRO_Vario"; // CV-M1109 + fbConveyor1110 : "FB_Conveyor"; // KR-M1110 + TRO218 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M1201 / Block 1.2.1 + TRO219 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M1202 / Block 1.2.3 + TRO220 : "FB_ILS_MTRO_1Sep"; // KR-M1203 + fbConveyor1204 : "FB_Conveyor"; // KR-M1204 + TRO222 : "FB_ILS_MTRO_Vario"; // CV-M1205 + TRO223 : "FB_ILS_MTRO_Vario"; // CV-M1206 + TRO224 : "FB_ILS_MTRO_Vario"; // CV-M1207 / Block 1.2.3 + TRO225 : "FB_ILS_MTRO_Vario"; // CV-M1208 + TRO226 : "FB_ILS_MTRO_Vario"; // CV-M1209 + TRO227 : "FB_ILS_MTRO_1Sep"; // KR-M1301 + TRO228 : "FB_ILS_MTRO_1Sep"; // KR-M1302 + TRO229 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M1303 / Block 1.3.1 + TRO230 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M1304 / Block 1.3.3 + TRO231 : "FB_ILS_MTRO_Vario"; // CV-M1305 + TRO232 : "FB_ILS_MTRO_Vario"; // CV-M1306 / Block 1.3.2 + TRO233 : "FB_ILS_MTRO_Vario"; // CV-M1307 + TRO234 : "FB_ILS_MTRO_Vario"; // CV-M1308 + TRO235 : "FB_ILS_MTRO_Vario"; // CV-M1309 + TRO236 : "FB_ILS_MTRO_Vario"; // CV-M1401 + TRO237 : "FB_ILS_MTRO_Vario"; // CV-M1501 + TRO238 : "FB_ILS_MTRO_Vario"; // CV-M1601 + TRO239 : "FB_ILS_MTRO_1Sep"; // CV-M1801 + TRO240 : "FB_ILS_MTRO_Vario"; // CV-M4701 + END_VAR + +BEGIN + REGION TRO201 (PinStore_Auto) — KR-K1101 / Block 1.1.1 + #TRO201.stInSeparator1.Settings.nSeparatorNo := "cSep201.1"; + #TRO201.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO201.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO201.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO201.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO201.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO201.stInSenJam2 := "DB_Inputs".Sensors["cInBG3065"]; + + #TRO201.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO201(nInMainTroNo := "cMainTro201", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea201".stJam201_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea201".stJam201_1.stData, + arInOutJamExit2 := "DB_JamArea201".stJam201_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea201".stJam201_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro201"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO201); + END_REGION + + REGION TRO202 (PinStore_Auto) — KR-K1102 / Block 1.1.3 + #TRO202.stInSeparator1.Settings.nSeparatorNo := "cSep202.1"; + #TRO202.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO202.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO202.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO202.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO202.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO202.stInSenJam2 := "DB_Inputs".Sensors["cInBG3125"]; + + #TRO202.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO202(nInMainTroNo := "cMainTro202", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea202".stJam202_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea202".stJam202_1.stData, + arInOutJamExit2 := "DB_JamArea202".stJam202_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea202".stJam202_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro202"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO202); + END_REGION + + REGION TRO203 (PinStore_Auto) — KR-K1201 / Block 1.2.1 + #TRO203.stInSeparator1.Settings.nSeparatorNo := "cSep203.1"; + #TRO203.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO203.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO203.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO203.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO203.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO203.stInSenJam2 := "DB_Inputs".Sensors["cInBG3553"]; + + #TRO203.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO203(nInMainTroNo := "cMainTro203", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea203".stJam203_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea203".stJam203_1.stData, + arInOutJamExit2 := "DB_JamArea203".stJam203_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea203".stJam203_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro203"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO203); + END_REGION + + REGION TRO204 (PinStore_Auto) — KR-K1202 / Block 1.2.3 + #TRO204.stInSeparator1.Settings.nSeparatorNo := "cSep204.1"; + #TRO204.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO204.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO204.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO204.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO204.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO204.stInSenJam2 := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO204.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO204(nInMainTroNo := "cMainTro204", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea204".stJam204_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea204".stJam204_1.stData, + arInOutJamExit2 := "DB_JamArea204".stJam204_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea204".stJam204_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro204"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO204); + END_REGION + + REGION TRO205 (PinStore_Auto) — KR-K1303 / Block 1.3.1 + #TRO205.stInSeparator1.Settings.nSeparatorNo := "cSep205.1"; + #TRO205.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO205.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO205.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO205.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO205.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO205.stInSenJam2 := "DB_Inputs".Sensors["cInBG4273"]; + + #TRO205.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO205(nInMainTroNo := "cMainTro205", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea205".stJam205_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea205".stJam205_1.stData, + arInOutJamExit2 := "DB_JamArea205".stJam205_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea205".stJam205_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro205"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO205); + END_REGION + + REGION TRO206 (PinStore_Auto) — KR-K1304 / Block 1.3.3 + #TRO206.stInSeparator1.Settings.nSeparatorNo := "cSep206.1"; + #TRO206.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO206.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO206.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO206.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO206.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO206.stInSenJam2 := "DB_Inputs".Sensors["cInBG4375"]; + + #TRO206.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO206(nInMainTroNo := "cMainTro206", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea206".stJam206_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea206".stJam206_1.stData, + arInOutJamExit2 := "DB_JamArea206".stJam206_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea206".stJam206_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro206"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO206); + END_REGION + + REGION TRO207 (1Sep) — KR-M1100 + #TRO207.stInSeparator1.Settings.nSeparatorNo := "cSep207.1"; + #TRO207.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO207.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO207.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO207.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO207.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4440"]; + #TRO207.stInSenJam2 := "DB_Inputs".Sensors["cInBG4442"]; + + #TRO207.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO207(nInMainTroNo := "cMainTro207", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea207".stJam207_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea207".stJam207_1.stData, + arInOutJamExit2 := "DB_JamArea207".stJam207_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea207".stJam207_2.stData, + xOutStopper1 => "MB4440", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro207"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO207); + END_REGION + + REGION TRO208 (PinStore_Auto) — KR-M1101 / Block 1.1.1 + #TRO208.stInSeparator1.Settings.nSeparatorNo := "cSep208.1"; + #TRO208.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO208.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO208.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO208.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO208.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO208.stInSenJam2 := "DB_Inputs".Sensors["cInBG3003"]; + + #TRO208.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO208(nInMainTroNo := "cMainTro208", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea208".stJam208_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea208".stJam208_1.stData, + arInOutJamExit2 := "DB_JamArea208".stJam208_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea208".stJam208_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro208"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO208); + END_REGION + + REGION TRO209 (PinStore_Auto) — KR-M1102 / Block 1.1.3 + #TRO209.stInSeparator1.Settings.nSeparatorNo := "cSep209.1"; + #TRO209.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO209.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO209.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO209.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO209.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO209.stInSenJam2 := "DB_Inputs".Sensors["cInBG3123"]; + + #TRO209.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO209(nInMainTroNo := "cMainTro209", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea209".stJam209_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea209".stJam209_1.stData, + arInOutJamExit2 := "DB_JamArea209".stJam209_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea209".stJam209_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro209"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO209); + END_REGION + + REGION TRO210 (1Sep) — KR-M1103 + #TRO210.stInSeparator1.Settings.nSeparatorNo := "cSep210.1"; + #TRO210.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO210.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO210.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO210.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO210.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3245"]; + #TRO210.stInSenJam2 := "DB_Inputs".Sensors["cInBG3242"]; + + #TRO210.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO210(nInMainTroNo := "cMainTro210", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea210".stJam210_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea210".stJam210_1.stData, + arInOutJamExit2 := "DB_JamArea210".stJam210_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea210".stJam210_2.stData, + xOutStopper1 => "MB3245", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro210"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO210); + END_REGION + + REGION TRO211 (1Sep) — CV-M1104 + #TRO211.stInSeparator1.Settings.nSeparatorNo := "cSep211.1"; + #TRO211.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO211.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO211.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO211.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO211.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3425"]; + #TRO211.stInSenJam2 := "DB_Inputs".Sensors["cInBG3362"]; + + #TRO211.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO211(nInMainTroNo := "cMainTro211", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea211".stJam211_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea211".stJam211_1.stData, + arInOutJamExit2 := "DB_JamArea211".stJam211_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea211".stJam211_2.stData, + xOutStopper1 => "MB3425", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro211"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO211); + END_REGION + + REGION TRO212 (Vario) — CV-M1105 + #TRO212.stInSeparator1.Settings.nSeparatorNo := "cSep212.1"; + #TRO212.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO212.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3000"]; + #TRO212.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3247"]; + #TRO212.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3243"]; + #TRO212.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3005"]; + + #TRO212(nInMainTroNo := "cMainTro212", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea212".stJam212_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea212".stJam212_1.stData, + arInOutJamFinger := "DB_JamArea212".stJam212_2.arCarrier, // TODO Topologie + xOutStopper => "MB3000", + xOutVarioMotor => "MA0142", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro212"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO212); + END_REGION + + REGION TRO213 (Vario) — CV-M1106 / Block 1.1.2 + #TRO213.stInSeparator1.Settings.nSeparatorNo := "cSep213.1"; + #TRO213.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO213.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3060"]; + #TRO213.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3307"]; + #TRO213.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO213.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3301"]; + + #TRO213(nInMainTroNo := "cMainTro213", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea213".stJam213_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea213".stJam213_1.stData, + arInOutJamFinger := "DB_JamArea213".stJam213_2.arCarrier, // TODO Topologie + xOutStopper => "MB3060", + xOutVarioMotor => "MA0143", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro213"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO213); + END_REGION + + REGION TRO214 (Vario) — CV-M1107 + #TRO214.stInSeparator1.Settings.nSeparatorNo := "cSep214.1"; + #TRO214.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO214.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3364"]; + #TRO214.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3367"]; + #TRO214.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3363"]; + #TRO214.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3361"]; + + #TRO214(nInMainTroNo := "cMainTro214", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea214".stJam214_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea214".stJam214_1.stData, + arInOutJamFinger := "DB_JamArea214".stJam214_2.arCarrier, // TODO Topologie + xOutStopper => "MB3364", + xOutVarioMotor => "MA0144", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro214"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO214); + END_REGION + + REGION TRO215 (Vario) — CV-M1108 / Block 1.1.4 + #TRO215.stInSeparator1.Settings.nSeparatorNo := "cSep215.1"; + #TRO215.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO215.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3424"]; + #TRO215.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3427"]; + #TRO215.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3423"]; + #TRO215.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3421"]; + + #TRO215(nInMainTroNo := "cMainTro215", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea215".stJam215_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea215".stJam215_1.stData, + arInOutJamFinger := "DB_JamArea215".stJam215_2.arCarrier, // TODO Topologie + xOutStopper => "MB3424", + xOutVarioMotor => "MA0145", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro215"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO215); + END_REGION + + REGION TRO216 (Vario) — CV-M1109 + #TRO216.stInSeparator1.Settings.nSeparatorNo := "cSep216.1"; + #TRO216.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO216.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3143"]; + #TRO216.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3145"]; + #TRO216.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3144"]; + #TRO216.stInVario.stSenJam := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO216(nInMainTroNo := "cMainTro216", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea216".stJam216_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea216".stJam216_1.stData, + arInOutJamFinger := "DB_JamArea216".stJam216_2.arCarrier, // TODO Topologie + xOutStopper => "MB3143", + xOutVarioMotor => "MA0146", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro216"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO216); + END_REGION + + REGION fbConveyor1110 — KR-M1110 + #fbConveyor1110.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor1110.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor1110.Settings.sMotorProtectName := 'FC0075'; + + #fbConveyor1110(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0075", + xInPowerContactor := "MA0075", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor1110); + END_REGION + + REGION TRO218 (PinStore_Auto) — KR-M1201 / Block 1.2.1 + #TRO218.stInSeparator1.Settings.nSeparatorNo := "cSep218.1"; + #TRO218.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO218.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO218.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO218.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO218.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO218.stInSenJam2 := "DB_Inputs".Sensors["cInBG3483"]; + + #TRO218.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO218(nInMainTroNo := "cMainTro218", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea218".stJam218_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea218".stJam218_1.stData, + arInOutJamExit2 := "DB_JamArea218".stJam218_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea218".stJam218_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro218"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO218); + END_REGION + + REGION TRO219 (PinStore_Auto) — KR-M1202 / Block 1.2.3 + #TRO219.stInSeparator1.Settings.nSeparatorNo := "cSep219.1"; + #TRO219.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO219.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO219.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO219.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO219.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO219.stInSenJam2 := "DB_Inputs".Sensors["cInBG3603"]; + + #TRO219.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO219(nInMainTroNo := "cMainTro219", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea219".stJam219_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea219".stJam219_1.stData, + arInOutJamExit2 := "DB_JamArea219".stJam219_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea219".stJam219_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro219"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO219); + END_REGION + + REGION TRO220 (1Sep) — KR-M1203 + #TRO220.stInSeparator1.Settings.nSeparatorNo := "cSep220.1"; + #TRO220.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO220.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO220.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO220.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO220.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3725"]; + #TRO220.stInSenJam2 := "DB_Inputs".Sensors["cInBG3722"]; + + #TRO220.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO220(nInMainTroNo := "cMainTro220", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea220".stJam220_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea220".stJam220_1.stData, + arInOutJamExit2 := "DB_JamArea220".stJam220_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea220".stJam220_2.stData, + xOutStopper1 => "MB3725", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro220"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO220); + END_REGION + + REGION fbConveyor1204 — KR-M1204 + #fbConveyor1204.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor1204.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor1204.Settings.sMotorProtectName := 'FC0201'; + + #fbConveyor1204(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0201", + xInPowerContactor := "MA0201", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor1204); + END_REGION + + REGION TRO222 (Vario) — CV-M1205 + #TRO222.stInSeparator1.Settings.nSeparatorNo := "cSep222.1"; + #TRO222.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO222.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3480"]; + #TRO222.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3727"]; + #TRO222.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3723"]; + #TRO222.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3485"]; + + #TRO222(nInMainTroNo := "cMainTro222", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea222".stJam222_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea222".stJam222_1.stData, + arInOutJamFinger := "DB_JamArea222".stJam222_2.arCarrier, // TODO Topologie + xOutStopper => "MB3480", + xOutVarioMotor => "MA0064", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro222"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO222); + END_REGION + + REGION TRO223 (Vario) — CV-M1206 + #TRO223.stInSeparator1.Settings.nSeparatorNo := "cSep223.1"; + #TRO223.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO223.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3540"]; + #TRO223.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3787"]; + #TRO223.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3783"]; + #TRO223.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3545"]; + + #TRO223(nInMainTroNo := "cMainTro223", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea223".stJam223_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea223".stJam223_1.stData, + arInOutJamFinger := "DB_JamArea223".stJam223_2.arCarrier, // TODO Topologie + xOutStopper => "MB3540", + xOutVarioMotor => "MA0065", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro223"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO223); + END_REGION + + REGION TRO224 (Vario) — CV-M1207 / Block 1.2.3 + #TRO224.stInSeparator1.Settings.nSeparatorNo := "cSep224.1"; + #TRO224.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO224.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3604"]; + #TRO224.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3847"]; + #TRO224.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3843"]; + #TRO224.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3841"]; + + #TRO224(nInMainTroNo := "cMainTro224", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea224".stJam224_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea224".stJam224_1.stData, + arInOutJamFinger := "DB_JamArea224".stJam224_2.arCarrier, // TODO Topologie + xOutStopper => "MB3604", + xOutVarioMotor => "MA0066", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro224"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO224); + END_REGION + + REGION TRO225 (Vario) — CV-M1208 + #TRO225.stInSeparator1.Settings.nSeparatorNo := "cSep225.1"; + #TRO225.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO225.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3660"]; + #TRO225.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3907"]; + #TRO225.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3903"]; + #TRO225.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3665"]; + + #TRO225(nInMainTroNo := "cMainTro225", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea225".stJam225_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea225".stJam225_1.stData, + arInOutJamFinger := "DB_JamArea225".stJam225_2.arCarrier, // TODO Topologie + xOutStopper => "MB3660", + xOutVarioMotor => "MA0067", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro225"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO225); + END_REGION + + REGION TRO226 (Vario) — CV-M1209 + #TRO226.stInSeparator1.Settings.nSeparatorNo := "cSep226.1"; + #TRO226.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO226.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3622"]; + #TRO226.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3624"]; + #TRO226.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3623"]; + #TRO226.stInVario.stSenJam := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO226(nInMainTroNo := "cMainTro226", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea226".stJam226_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea226".stJam226_1.stData, + arInOutJamFinger := "DB_JamArea226".stJam226_2.arCarrier, // TODO Topologie + xOutStopper => "MB3622", + xOutVarioMotor => "MA0070", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro226"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO226); + END_REGION + + REGION TRO227 (1Sep) — KR-M1301 + #TRO227.stInSeparator1.Settings.nSeparatorNo := "cSep227.1"; + #TRO227.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO227.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO227.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO227.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO227.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3965"]; + #TRO227.stInSenJam2 := "DB_Inputs".Sensors["cInBG3962"]; + + #TRO227.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO227(nInMainTroNo := "cMainTro227", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea227".stJam227_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea227".stJam227_1.stData, + arInOutJamExit2 := "DB_JamArea227".stJam227_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea227".stJam227_2.stData, + xOutStopper1 => "MB3965", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro227"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO227); + END_REGION + + REGION TRO228 (1Sep) — KR-M1302 + #TRO228.stInSeparator1.Settings.nSeparatorNo := "cSep228.1"; + #TRO228.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO228.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO228.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO228.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO228.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4080"]; + #TRO228.stInSenJam2 := "DB_Inputs".Sensors["cInBG4082"]; + + #TRO228.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO228(nInMainTroNo := "cMainTro228", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea228".stJam228_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea228".stJam228_1.stData, + arInOutJamExit2 := "DB_JamArea228".stJam228_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea228".stJam228_2.stData, + xOutStopper1 => "MB4080", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro228"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO228); + END_REGION + + REGION TRO229 (PinStore_Auto) — KR-M1303 / Block 1.3.1 + #TRO229.stInSeparator1.Settings.nSeparatorNo := "cSep229.1"; + #TRO229.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO229.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO229.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO229.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO229.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO229.stInSenJam2 := "DB_Inputs".Sensors["cInBG4203"]; + + #TRO229.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO229(nInMainTroNo := "cMainTro229", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea229".stJam229_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea229".stJam229_1.stData, + arInOutJamExit2 := "DB_JamArea229".stJam229_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea229".stJam229_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro229"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO229); + END_REGION + + REGION TRO230 (PinStore_Auto) — KR-M1304 / Block 1.3.3 + #TRO230.stInSeparator1.Settings.nSeparatorNo := "cSep230.1"; + #TRO230.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO230.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO230.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO230.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO230.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO230.stInSenJam2 := "DB_Inputs".Sensors["cInBG4323"]; + + #TRO230.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO230(nInMainTroNo := "cMainTro230", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea230".stJam230_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea230".stJam230_1.stData, + arInOutJamExit2 := "DB_JamArea230".stJam230_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea230".stJam230_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro230"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO230); + END_REGION + + REGION TRO231 (Vario) — CV-M1305 + #TRO231.stInSeparator1.Settings.nSeparatorNo := "cSep231.1"; + #TRO231.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO231.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3960"]; + #TRO231.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3967"]; + #TRO231.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3963"]; + #TRO231.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3961"]; + + #TRO231(nInMainTroNo := "cMainTro231", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea231".stJam231_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea231".stJam231_1.stData, + arInOutJamFinger := "DB_JamArea231".stJam231_2.arCarrier, // TODO Topologie + xOutStopper => "MB3960", + xOutVarioMotor => "MA0262", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro231"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO231); + END_REGION + + REGION TRO232 (Vario) — CV-M1306 / Block 1.3.2 + #TRO232.stInSeparator1.Settings.nSeparatorNo := "cSep232.1"; + #TRO232.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO232.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4024"]; + #TRO232.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4027"]; + #TRO232.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4023"]; + #TRO232.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4021"]; + + #TRO232(nInMainTroNo := "cMainTro232", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea232".stJam232_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea232".stJam232_1.stData, + arInOutJamFinger := "DB_JamArea232".stJam232_2.arCarrier, // TODO Topologie + xOutStopper => "MB4024", + xOutVarioMotor => "MA0263", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro232"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO232); + END_REGION + + REGION TRO233 (Vario) — CV-M1307 + #TRO233.stInSeparator1.Settings.nSeparatorNo := "cSep233.1"; + #TRO233.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO233.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4084"]; + #TRO233.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4087"]; + #TRO233.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4083"]; + #TRO233.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4081"]; + + #TRO233(nInMainTroNo := "cMainTro233", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea233".stJam233_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea233".stJam233_1.stData, + arInOutJamFinger := "DB_JamArea233".stJam233_2.arCarrier, // TODO Topologie + xOutStopper => "MB4084", + xOutVarioMotor => "MA0264", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro233"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO233); + END_REGION + + REGION TRO234 (Vario) — CV-M1308 + #TRO234.stInSeparator1.Settings.nSeparatorNo := "cSep234.1"; + #TRO234.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO234.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4144"]; + #TRO234.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4147"]; + #TRO234.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4143"]; + #TRO234.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4141"]; + + #TRO234(nInMainTroNo := "cMainTro234", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea234".stJam234_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea234".stJam234_1.stData, + arInOutJamFinger := "DB_JamArea234".stJam234_2.arCarrier, // TODO Topologie + xOutStopper => "MB4144", + xOutVarioMotor => "MA0265", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro234"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO234); + END_REGION + + REGION TRO235 (Vario) — CV-M1309 + #TRO235.stInSeparator1.Settings.nSeparatorNo := "cSep235.1"; + #TRO235.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO235.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4334"]; + #TRO235.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4344"]; + #TRO235.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4343"]; + #TRO235.stInVario.stSenJam := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO235(nInMainTroNo := "cMainTro235", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea235".stJam235_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea235".stJam235_1.stData, + arInOutJamFinger := "DB_JamArea235".stJam235_2.arCarrier, // TODO Topologie + xOutStopper => "MB4342", + xOutVarioMotor => "MA0266", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro235"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO235); + END_REGION + + REGION TRO236 (Vario) — CV-M1401 + #TRO236.stInSeparator1.Settings.nSeparatorNo := "cSep236.1"; + #TRO236.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO236.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4445"]; + #TRO236.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4461"]; + #TRO236.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4462"]; + #TRO236.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4447"]; + + #TRO236(nInMainTroNo := "cMainTro236", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea236".stJam236_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea236".stJam236_1.stData, + arInOutJamFinger := "DB_JamArea236".stJam236_2.arCarrier, // TODO Topologie + xOutStopper => "MB4460", + xOutVarioMotor => "MA0071", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro236"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO236); + END_REGION + + REGION TRO237 (Vario) — CV-M1501 + #TRO237.stInSeparator1.Settings.nSeparatorNo := "cSep237.1"; + #TRO237.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO237.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4522"]; + #TRO237.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4542"]; + #TRO237.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4541"]; + #TRO237.stInVario.stSenJam := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO237(nInMainTroNo := "cMainTro237", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea237".stJam237_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea237".stJam237_1.stData, + arInOutJamFinger := "DB_JamArea237".stJam237_2.arCarrier, // TODO Topologie + xOutStopper => "MB4512", + xOutVarioMotor => "MA0072", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro237"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO237); + END_REGION + + REGION TRO238 (Vario) — CV-M1601 + #TRO238.stInSeparator1.Settings.nSeparatorNo := "cSep238.1"; + #TRO238.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO238.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4526"]; + #TRO238.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4545"]; + #TRO238.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4544"]; + #TRO238.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4525"]; + + #TRO238(nInMainTroNo := "cMainTro238", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea238".stJam238_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea238".stJam238_1.stData, + arInOutJamFinger := "DB_JamArea238".stJam238_2.arCarrier, // TODO Topologie + xOutStopper => "MB4526", + xOutVarioMotor => "MA0073", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro238"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO238); + END_REGION + + REGION TRO239 (1Sep) — CV-M1801 + #TRO239.stInSeparator1.Settings.nSeparatorNo := "cSep239.1"; + #TRO239.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO239.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO239.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO239.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO239.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4535"]; + #TRO239.stInSenJam2 := "DB_Inputs".Sensors["cInBG4534"]; + + #TRO239.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO239(nInMainTroNo := "cMainTro239", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea239".stJam239_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea239".stJam239_1.stData, + arInOutJamExit2 := "DB_JamArea239".stJam239_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea239".stJam239_2.stData, + xOutStopper1 => "MB4535", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro239"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO239); + END_REGION + + REGION TRO240 (Vario) — CV-M4701 + #TRO240.stInSeparator1.Settings.nSeparatorNo := "cSep240.1"; + #TRO240.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO240.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4530"]; + #TRO240.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4533"]; + #TRO240.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4531"]; + #TRO240.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4532"]; + + #TRO240(nInMainTroNo := "cMainTro240", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea240".stJam240_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea240".stJam240_1.stData, + arInOutJamFinger := "DB_JamArea240".stJam240_2.arCarrier, // TODO Topologie + xOutStopper => "MB4530", + xOutVarioMotor => "MA0074", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro240"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO240); + END_REGION + +END_FUNCTION_BLOCK diff --git a/results/FB_Main_skel_UH03.scl b/results/FB_Main_skel_UH03.scl new file mode 100644 index 0000000..b24933b --- /dev/null +++ b/results/FB_Main_skel_UH03.scl @@ -0,0 +1,1076 @@ +FUNCTION_BLOCK "FB_Main_skel_UH03" +{ S7_Optimized_Access := 'TRUE' } +VERSION : 0.1 +// ============================================================ +// AUTOMATISCH GENERIERTES GRUNDGERUEST — create_skel.py +// Quelle: E/A-Listen UH03 (data/) +// TODO-Marken kennzeichnen manuell zu ergaenzende Stellen +// (Timings, Topologie/JamAreas, Safety, Release, Priority). +// ============================================================ + VAR + TRO301 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K2101 / Block 2.1.1 + TRO302 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K2102 / Block 2.1.3 + TRO303 : "FB_ILS_MTRO_1Sep"; // KR-K2110 + TRO304 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K2201 / Block 2.2.1 + TRO305 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K2202 / Block 2.2.3 + TRO306 : "FB_ILS_MTRO_1Sep1Swi"; // KR-K2210 / Block 2.3.4 + TRO307 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K2303 / Block 2.3.1 + TRO308 : "FB_ILS_MTRO_PinStore_Auto"; // KR-K2304 / Block 2.3.3 + fbConveyor0201 : "FB_Conveyor"; // KR-M0201 + TRO310 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M2101 / Block 2.1.1 + TRO311 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M2102 / Block 2.1.3 + TRO312 : "FB_ILS_MTRO_1Sep"; // KR-M2103 / Block 2.1.2 + TRO313 : "FB_ILS_MTRO_1Sep"; // CV-M2104 / Block 2.1.4 + TRO314 : "FB_ILS_MTRO_Vario"; // CV-M2105 + TRO315 : "FB_ILS_MTRO_Vario"; // CV-M2106 + TRO316 : "FB_ILS_MTRO_Vario"; // CV-M2107 + TRO317 : "FB_ILS_MTRO_Vario"; // CV-M2108 + TRO318 : "FB_ILS_MTRO_Vario"; // CV-M2109 / Block 2.1.4 + TRO319 : "FB_ILS_MTRO_1Sep"; // KR-M2110 + TRO320 : "FB_ILS_MTRO_Vario"; // CV-M2111 + fbConveyor2112 : "FB_Conveyor"; // KR-M2112 + TRO322 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M2201 / Block 2.2.1 + TRO323 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M2202 / Block 2.2.3 + TRO324 : "FB_ILS_MTRO_1Sep"; // KR-M2203 + TRO325 : "FB_ILS_MTRO_1Sep"; // KR-M2204 + TRO326 : "FB_ILS_MTRO_Vario"; // CV-M2205 / Block 2.2.1 + TRO327 : "FB_ILS_MTRO_Vario"; // CV-M2206 / Block 2.2.2 + TRO328 : "FB_ILS_MTRO_Vario"; // CV-M2207 / Block 2.2.3 + TRO329 : "FB_ILS_MTRO_Vario"; // CV-M2208 + TRO330 : "FB_ILS_MTRO_Vario"; // CV-M2209 / Block 2.1.4 + TRO331 : "FB_ILS_MTRO_1Sep"; // KR-M2301 + fbConveyor2302 : "FB_Conveyor"; // KR-M2302 / Block 2.3.4 + TRO333 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M2303 / Block 2.3.1 + TRO334 : "FB_ILS_MTRO_PinStore_Auto"; // KR-M2304 / Block 2.3.3 + TRO335 : "FB_ILS_MTRO_Vario"; // CV-M2305 / Block 2.3.1 + fbConveyor2306 : "FB_Conveyor"; // CV-M2306 + fbConveyor2307 : "FB_Conveyor"; // CV-M2307 + TRO338 : "FB_ILS_MTRO_Vario"; // CV-M2308 / Block 2.3.3 + TRO339 : "FB_ILS_MTRO_Vario"; // CV-M2309 + TRO340 : "FB_ILS_MTRO_Vario"; // CV-M4101 + TRO341 : "FB_ILS_MTRO_Vario"; // CV-M4102 + TRO342 : "FB_ILS_MTRO_Vario"; // CV-M4201 + TRO343 : "FB_ILS_MTRO_Vario"; // CV-M4202 + TRO344 : "FB_ILS_MTRO_Vario"; // CV-M4301 + TRO345 : "FB_ILS_MTRO_Vario"; // CV-M4401 + END_VAR + +BEGIN + REGION TRO301 (PinStore_Auto) — KR-K2101 / Block 2.1.1 + #TRO301.stInSeparator1.Settings.nSeparatorNo := "cSep301.1"; + #TRO301.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO301.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO301.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO301.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO301.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO301.stInSenJam2 := "DB_Inputs".Sensors["cInBG3065"]; + + #TRO301.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO301(nInMainTroNo := "cMainTro301", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea301".stJam301_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea301".stJam301_1.stData, + arInOutJamExit2 := "DB_JamArea301".stJam301_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea301".stJam301_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro301"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO301); + END_REGION + + REGION TRO302 (PinStore_Auto) — KR-K2102 / Block 2.1.3 + #TRO302.stInSeparator1.Settings.nSeparatorNo := "cSep302.1"; + #TRO302.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO302.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO302.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO302.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO302.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO302.stInSenJam2 := "DB_Inputs".Sensors["cInBG3185"]; + + #TRO302.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO302(nInMainTroNo := "cMainTro302", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea302".stJam302_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea302".stJam302_1.stData, + arInOutJamExit2 := "DB_JamArea302".stJam302_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea302".stJam302_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro302"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO302); + END_REGION + + REGION TRO303 (1Sep) — KR-K2110 + #TRO303.stInSeparator1.Settings.nSeparatorNo := "cSep303.1"; + #TRO303.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO303.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO303.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO303.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO303.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4444"]; + #TRO303.stInSenJam2 := "DB_Inputs".Sensors["cInBG4443"]; + + #TRO303.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO303(nInMainTroNo := "cMainTro303", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea303".stJam303_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea303".stJam303_1.stData, + arInOutJamExit2 := "DB_JamArea303".stJam303_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea303".stJam303_2.stData, + xOutStopper1 => "MB4444", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro303"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO303); + END_REGION + + REGION TRO304 (PinStore_Auto) — KR-K2201 / Block 2.2.1 + #TRO304.stInSeparator1.Settings.nSeparatorNo := "cSep304.1"; + #TRO304.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO304.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO304.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO304.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO304.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO304.stInSenJam2 := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO304.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO304(nInMainTroNo := "cMainTro304", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea304".stJam304_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea304".stJam304_1.stData, + arInOutJamExit2 := "DB_JamArea304".stJam304_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea304".stJam304_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro304"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO304); + END_REGION + + REGION TRO305 (PinStore_Auto) — KR-K2202 / Block 2.2.3 + #TRO305.stInSeparator1.Settings.nSeparatorNo := "cSep305.1"; + #TRO305.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO305.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO305.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO305.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO305.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO305.stInSenJam2 := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO305.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO305(nInMainTroNo := "cMainTro305", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea305".stJam305_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea305".stJam305_1.stData, + arInOutJamExit2 := "DB_JamArea305".stJam305_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea305".stJam305_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro305"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO305); + END_REGION + + REGION TRO306 (1Sep1Swi) — KR-K2210 / Block 2.3.4 + #TRO306.stInSeparator1.Settings.nSeparatorNo := "cSep306.1"; + #TRO306.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO306.stInSeparator1.Settings.tTrailingTime := T#100ms; // TODO Timing + #TRO306.stInSeparator1.Settings.tHandlingTime := T#50ms; // TODO Timing + #TRO306.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO306.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4395"]; + #TRO306.stInSenJam2 := "DB_Inputs".Sensors["cInBG4507"]; + #TRO306.stInSwitch1.Settings.nSwitchNo := "cSwi306.1"; + + #TRO306(nInMainTroNo := "cMainTro306", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun1 := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea306".stJam306_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea306".stJam306_1.stData, + arInOutJamExit2 := "DB_JamArea306".stJam306_2.arCarrier, // TODO Topologie (Dir1) + stInOutJamExit2 := "DB_JamArea306".stJam306_2.stData, + arInOutJamExit3 := "DB_JamArea306".stJam306_3.arCarrier, // TODO Topologie (Dir2) + stInOutJamExit3 := "DB_JamArea306".stJam306_3.stData, + xOutStopper1 => "MB4395", + xOutSw1ExTo3 => "MB4392", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro306"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO306); + END_REGION + + REGION TRO307 (PinStore_Auto) — KR-K2303 / Block 2.3.1 + #TRO307.stInSeparator1.Settings.nSeparatorNo := "cSep307.1"; + #TRO307.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO307.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO307.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO307.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO307.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO307.stInSenJam2 := "DB_Inputs".Sensors["cInBG4273"]; + + #TRO307.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO307(nInMainTroNo := "cMainTro307", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea307".stJam307_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea307".stJam307_1.stData, + arInOutJamExit2 := "DB_JamArea307".stJam307_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea307".stJam307_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro307"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO307); + END_REGION + + REGION TRO308 (PinStore_Auto) — KR-K2304 / Block 2.3.3 + #TRO308.stInSeparator1.Settings.nSeparatorNo := "cSep308.1"; + #TRO308.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO308.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO308.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO308.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO308.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO308.stInSenJam2 := "DB_Inputs".Sensors["cInBG4375"]; + + #TRO308.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO308(nInMainTroNo := "cMainTro308", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea308".stJam308_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea308".stJam308_1.stData, + arInOutJamExit2 := "DB_JamArea308".stJam308_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea308".stJam308_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro308"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO308); + END_REGION + + REGION fbConveyor0201 — KR-M0201 + #fbConveyor0201.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor0201.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor0201.Settings.sMotorProtectName := 'FC0201'; + + #fbConveyor0201(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0201", + xInPowerContactor := "MAxxxx", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor0201); + END_REGION + + REGION TRO310 (PinStore_Auto) — KR-M2101 / Block 2.1.1 + #TRO310.stInSeparator1.Settings.nSeparatorNo := "cSep310.1"; + #TRO310.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO310.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO310.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO310.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO310.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO310.stInSenJam2 := "DB_Inputs".Sensors["cInBG3003"]; + + #TRO310.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO310(nInMainTroNo := "cMainTro310", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea310".stJam310_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea310".stJam310_1.stData, + arInOutJamExit2 := "DB_JamArea310".stJam310_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea310".stJam310_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro310"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO310); + END_REGION + + REGION TRO311 (PinStore_Auto) — KR-M2102 / Block 2.1.3 + #TRO311.stInSeparator1.Settings.nSeparatorNo := "cSep311.1"; + #TRO311.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO311.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO311.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO311.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO311.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3134"]; + #TRO311.stInSenJam2 := "DB_Inputs".Sensors["cInBG3123"]; + + #TRO311.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO311(nInMainTroNo := "cMainTro311", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea311".stJam311_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea311".stJam311_1.stData, + arInOutJamExit2 := "DB_JamArea311".stJam311_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea311".stJam311_2.stData, + xOutStopper1 => "MB3134", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro311"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO311); + END_REGION + + REGION TRO312 (1Sep) — KR-M2103 / Block 2.1.2 + #TRO312.stInSeparator1.Settings.nSeparatorNo := "cSep312.1"; + #TRO312.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO312.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO312.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO312.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO312.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3245"]; + #TRO312.stInSenJam2 := "DB_Inputs".Sensors["cInBG3242"]; + + #TRO312.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO312(nInMainTroNo := "cMainTro312", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea312".stJam312_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea312".stJam312_1.stData, + arInOutJamExit2 := "DB_JamArea312".stJam312_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea312".stJam312_2.stData, + xOutStopper1 => "MB3245", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro312"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO312); + END_REGION + + REGION TRO313 (1Sep) — CV-M2104 / Block 2.1.4 + #TRO313.stInSeparator1.Settings.nSeparatorNo := "cSep313.1"; + #TRO313.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO313.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO313.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO313.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO313.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3425"]; + #TRO313.stInSenJam2 := "DB_Inputs".Sensors["cInBG3362"]; + + #TRO313.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO313(nInMainTroNo := "cMainTro313", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea313".stJam313_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea313".stJam313_1.stData, + arInOutJamExit2 := "DB_JamArea313".stJam313_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea313".stJam313_2.stData, + xOutStopper1 => "MB3425", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro313"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO313); + END_REGION + + REGION TRO314 (Vario) — CV-M2105 + #TRO314.stInSeparator1.Settings.nSeparatorNo := "cSep314.1"; + #TRO314.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO314.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3244"]; + #TRO314.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3247"]; + #TRO314.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3243"]; + #TRO314.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3241"]; + + #TRO314(nInMainTroNo := "cMainTro314", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea314".stJam314_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea314".stJam314_1.stData, + arInOutJamFinger := "DB_JamArea314".stJam314_2.arCarrier, // TODO Topologie + xOutStopper => "MB3244", + xOutVarioMotor => "MA0142", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro314"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO314); + END_REGION + + REGION TRO315 (Vario) — CV-M2106 + #TRO315.stInSeparator1.Settings.nSeparatorNo := "cSep315.1"; + #TRO315.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO315.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3304"]; + #TRO315.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3307"]; + #TRO315.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3303"]; + #TRO315.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3301"]; + + #TRO315(nInMainTroNo := "cMainTro315", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea315".stJam315_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea315".stJam315_1.stData, + arInOutJamFinger := "DB_JamArea315".stJam315_2.arCarrier, // TODO Topologie + xOutStopper => "MB3304", + xOutVarioMotor => "MA0143", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro315"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO315); + END_REGION + + REGION TRO316 (Vario) — CV-M2107 + #TRO316.stInSeparator1.Settings.nSeparatorNo := "cSep316.1"; + #TRO316.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO316.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3364"]; + #TRO316.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3367"]; + #TRO316.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3363"]; + #TRO316.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3361"]; + + #TRO316(nInMainTroNo := "cMainTro316", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea316".stJam316_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea316".stJam316_1.stData, + arInOutJamFinger := "DB_JamArea316".stJam316_2.arCarrier, // TODO Topologie + xOutStopper => "MB3364", + xOutVarioMotor => "MA0144", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro316"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO316); + END_REGION + + REGION TRO317 (Vario) — CV-M2108 + #TRO317.stInSeparator1.Settings.nSeparatorNo := "cSep317.1"; + #TRO317.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO317.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3424"]; + #TRO317.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3427"]; + #TRO317.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3423"]; + #TRO317.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3421"]; + + #TRO317(nInMainTroNo := "cMainTro317", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea317".stJam317_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea317".stJam317_1.stData, + arInOutJamFinger := "DB_JamArea317".stJam317_2.arCarrier, // TODO Topologie + xOutStopper => "MB3424", + xOutVarioMotor => "MA0145", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro317"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO317); + END_REGION + + REGION TRO318 (Vario) — CV-M2109 / Block 2.1.4 + #TRO318.stInSeparator1.Settings.nSeparatorNo := "cSep318.1"; + #TRO318.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO318.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3432"]; + #TRO318.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3441"]; + #TRO318.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3442"]; + #TRO318.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3435"]; + + #TRO318(nInMainTroNo := "cMainTro318", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea318".stJam318_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea318".stJam318_1.stData, + arInOutJamFinger := "DB_JamArea318".stJam318_2.arCarrier, // TODO Topologie + xOutStopper => "MB3432", + xOutVarioMotor => "MA0070", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro318"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO318); + END_REGION + + REGION TRO319 (1Sep) — KR-M2110 + #TRO319.stInSeparator1.Settings.nSeparatorNo := "cSep319.1"; + #TRO319.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO319.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO319.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO319.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO319.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4500"]; + #TRO319.stInSenJam2 := "DB_Inputs".Sensors["cInBG4504"]; + + #TRO319.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO319(nInMainTroNo := "cMainTro319", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea319".stJam319_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea319".stJam319_1.stData, + arInOutJamExit2 := "DB_JamArea319".stJam319_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea319".stJam319_2.stData, + xOutStopper1 => "MB4500", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro319"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO319); + END_REGION + + REGION TRO320 (Vario) — CV-M2111 + #TRO320.stInSeparator1.Settings.nSeparatorNo := "cSep320.1"; + #TRO320.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO320.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4450"]; + #TRO320.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4452"]; + #TRO320.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4451"]; + #TRO320.stInVario.stSenJam := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO320(nInMainTroNo := "cMainTro320", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea320".stJam320_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea320".stJam320_1.stData, + arInOutJamFinger := "DB_JamArea320".stJam320_2.arCarrier, // TODO Topologie + xOutStopper => "MB4450", + xOutVarioMotor => "MA0073", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro320"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO320); + END_REGION + + REGION fbConveyor2112 — KR-M2112 + #fbConveyor2112.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor2112.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor2112.Settings.sMotorProtectName := 'FC0072'; + + #fbConveyor2112(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0072", + xInPowerContactor := "MA0072", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor2112); + END_REGION + + REGION TRO322 (PinStore_Auto) — KR-M2201 / Block 2.2.1 + #TRO322.stInSeparator1.Settings.nSeparatorNo := "cSep322.1"; + #TRO322.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO322.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO322.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO322.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO322.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO322.stInSenJam2 := "DB_Inputs".Sensors["cInBG3483"]; + + #TRO322.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO322(nInMainTroNo := "cMainTro322", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea322".stJam322_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea322".stJam322_1.stData, + arInOutJamExit2 := "DB_JamArea322".stJam322_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea322".stJam322_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro322"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO322); + END_REGION + + REGION TRO323 (PinStore_Auto) — KR-M2202 / Block 2.2.3 + #TRO323.stInSeparator1.Settings.nSeparatorNo := "cSep323.1"; + #TRO323.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO323.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO323.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO323.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO323.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO323.stInSenJam2 := "DB_Inputs".Sensors["cInBG3603"]; + + #TRO323.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO323(nInMainTroNo := "cMainTro323", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea323".stJam323_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea323".stJam323_1.stData, + arInOutJamExit2 := "DB_JamArea323".stJam323_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea323".stJam323_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro323"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO323); + END_REGION + + REGION TRO324 (1Sep) — KR-M2203 + #TRO324.stInSeparator1.Settings.nSeparatorNo := "cSep324.1"; + #TRO324.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO324.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO324.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO324.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO324.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3725"]; + #TRO324.stInSenJam2 := "DB_Inputs".Sensors["cInBG3722"]; + + #TRO324.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO324(nInMainTroNo := "cMainTro324", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea324".stJam324_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea324".stJam324_1.stData, + arInOutJamExit2 := "DB_JamArea324".stJam324_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea324".stJam324_2.stData, + xOutStopper1 => "MB3725", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro324"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO324); + END_REGION + + REGION TRO325 (1Sep) — KR-M2204 + #TRO325.stInSeparator1.Settings.nSeparatorNo := "cSep325.1"; + #TRO325.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO325.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO325.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO325.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO325.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3900"]; + #TRO325.stInSenJam2 := "DB_Inputs".Sensors["cInBG3842"]; + + #TRO325.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO325(nInMainTroNo := "cMainTro325", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea325".stJam325_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea325".stJam325_1.stData, + arInOutJamExit2 := "DB_JamArea325".stJam325_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea325".stJam325_2.stData, + xOutStopper1 => "MB3900", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro325"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO325); + END_REGION + + REGION TRO326 (Vario) — CV-M2205 / Block 2.2.1 + #TRO326.stInSeparator1.Settings.nSeparatorNo := "cSep326.1"; + #TRO326.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO326.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3724"]; + #TRO326.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3727"]; + #TRO326.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO326.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3721"]; + + #TRO326(nInMainTroNo := "cMainTro326", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea326".stJam326_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea326".stJam326_1.stData, + arInOutJamFinger := "DB_JamArea326".stJam326_2.arCarrier, // TODO Topologie + xOutStopper => "MB3724", + xOutVarioMotor => "MA0064", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro326"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO326); + END_REGION + + REGION TRO327 (Vario) — CV-M2206 / Block 2.2.2 + #TRO327.stInSeparator1.Settings.nSeparatorNo := "cSep327.1"; + #TRO327.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO327.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3784"]; + #TRO327.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3787"]; + #TRO327.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3783"]; + #TRO327.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3781"]; + + #TRO327(nInMainTroNo := "cMainTro327", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea327".stJam327_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea327".stJam327_1.stData, + arInOutJamFinger := "DB_JamArea327".stJam327_2.arCarrier, // TODO Topologie + xOutStopper => "MB3784", + xOutVarioMotor => "MA0065", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro327"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO327); + END_REGION + + REGION TRO328 (Vario) — CV-M2207 / Block 2.2.3 + #TRO328.stInSeparator1.Settings.nSeparatorNo := "cSep328.1"; + #TRO328.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO328.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3844"]; + #TRO328.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3847"]; + #TRO328.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3843"]; + #TRO328.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3841"]; + + #TRO328(nInMainTroNo := "cMainTro328", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea328".stJam328_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea328".stJam328_1.stData, + arInOutJamFinger := "DB_JamArea328".stJam328_2.arCarrier, // TODO Topologie + xOutStopper => "MB3844", + xOutVarioMotor => "MA0066", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro328"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO328); + END_REGION + + REGION TRO329 (Vario) — CV-M2208 + #TRO329.stInSeparator1.Settings.nSeparatorNo := "cSep329.1"; + #TRO329.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO329.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3904"]; + #TRO329.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3907"]; + #TRO329.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3903"]; + #TRO329.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3901"]; + + #TRO329(nInMainTroNo := "cMainTro329", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea329".stJam329_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea329".stJam329_1.stData, + arInOutJamFinger := "DB_JamArea329".stJam329_2.arCarrier, // TODO Topologie + xOutStopper => "MB3904", + xOutVarioMotor => "MA0067", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro329"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO329); + END_REGION + + REGION TRO330 (Vario) — CV-M2209 / Block 2.1.4 + #TRO330.stInSeparator1.Settings.nSeparatorNo := "cSep330.1"; + #TRO330.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO330.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3912"]; + #TRO330.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3921"]; + #TRO330.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3922"]; + #TRO330.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3915"]; + + #TRO330(nInMainTroNo := "cMainTro330", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea330".stJam330_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea330".stJam330_1.stData, + arInOutJamFinger := "DB_JamArea330".stJam330_2.arCarrier, // TODO Topologie + xOutStopper => "MB3912", + xOutVarioMotor => "MA0205", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro330"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO330); + END_REGION + + REGION TRO331 (1Sep) — KR-M2301 + #TRO331.stInSeparator1.Settings.nSeparatorNo := "cSep331.1"; + #TRO331.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO331.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO331.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO331.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO331.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3965"]; + #TRO331.stInSenJam2 := "DB_Inputs".Sensors["cInBG3962"]; + + #TRO331.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO331(nInMainTroNo := "cMainTro331", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea331".stJam331_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea331".stJam331_1.stData, + arInOutJamExit2 := "DB_JamArea331".stJam331_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea331".stJam331_2.stData, + xOutStopper1 => "MB3965", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro331"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO331); + END_REGION + + REGION fbConveyor2302 — KR-M2302 / Block 2.3.4 + #fbConveyor2302.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor2302.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor2302.Settings.sMotorProtectName := 'FC0203'; + + #fbConveyor2302(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0203", + xInPowerContactor := "MA0203", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor2302); + END_REGION + + REGION TRO333 (PinStore_Auto) — KR-M2303 / Block 2.3.1 + #TRO333.stInSeparator1.Settings.nSeparatorNo := "cSep333.1"; + #TRO333.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO333.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO333.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO333.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO333.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO333.stInSenJam2 := "DB_Inputs".Sensors["cInBG4203"]; + + #TRO333.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO333(nInMainTroNo := "cMainTro333", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea333".stJam333_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea333".stJam333_1.stData, + arInOutJamExit2 := "DB_JamArea333".stJam333_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea333".stJam333_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro333"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO333); + END_REGION + + REGION TRO334 (PinStore_Auto) — KR-M2304 / Block 2.3.3 + #TRO334.stInSeparator1.Settings.nSeparatorNo := "cSep334.1"; + #TRO334.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO334.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO334.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO334.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO334.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO334.stInSenJam2 := "DB_Inputs".Sensors["cInBG4323"]; + + #TRO334.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO334(nInMainTroNo := "cMainTro334", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea334".stJam334_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea334".stJam334_1.stData, + arInOutJamExit2 := "DB_JamArea334".stJam334_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea334".stJam334_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro334"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO334); + END_REGION + + REGION TRO335 (Vario) — CV-M2305 / Block 2.3.1 + #TRO335.stInSeparator1.Settings.nSeparatorNo := "cSep335.1"; + #TRO335.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO335.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3964"]; + #TRO335.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3967"]; + #TRO335.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3963"]; + #TRO335.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3961"]; + + #TRO335(nInMainTroNo := "cMainTro335", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea335".stJam335_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea335".stJam335_1.stData, + arInOutJamFinger := "DB_JamArea335".stJam335_2.arCarrier, // TODO Topologie + xOutStopper => "MB3964", + xOutVarioMotor => "MA0262", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro335"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO335); + END_REGION + + REGION fbConveyor2306 — CV-M2306 + #fbConveyor2306.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor2306.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor2306.Settings.sMotorProtectName := 'FC0263'; + + #fbConveyor2306(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0263", + xInPowerContactor := "MA0263", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor2306); + END_REGION + + REGION fbConveyor2307 — CV-M2307 + #fbConveyor2307.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor2307.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor2307.Settings.sMotorProtectName := 'FC0264'; + + #fbConveyor2307(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FC0264", + xInPowerContactor := "MAxxxx", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor2307); + END_REGION + + REGION TRO338 (Vario) — CV-M2308 / Block 2.3.3 + #TRO338.stInSeparator1.Settings.nSeparatorNo := "cSep338.1"; + #TRO338.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO338.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4084"]; + #TRO338.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4147"]; + #TRO338.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4143"]; + #TRO338.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4081"]; + + #TRO338(nInMainTroNo := "cMainTro338", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea338".stJam338_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea338".stJam338_1.stData, + arInOutJamFinger := "DB_JamArea338".stJam338_2.arCarrier, // TODO Topologie + xOutStopper => "MB4084", + xOutVarioMotor => "MA0265", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro338"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO338); + END_REGION + + REGION TRO339 (Vario) — CV-M2309 + #TRO339.stInSeparator1.Settings.nSeparatorNo := "cSep339.1"; + #TRO339.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO339.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4095"]; + #TRO339.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4096"]; + #TRO339.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4097"]; + #TRO339.stInVario.stSenJam := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO339(nInMainTroNo := "cMainTro339", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea339".stJam339_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea339".stJam339_1.stData, + arInOutJamFinger := "DB_JamArea339".stJam339_2.arCarrier, // TODO Topologie + xOutStopper => "MB4095", + xOutVarioMotor => "MA0204", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro339"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO339); + END_REGION + + REGION TRO340 (Vario) — CV-M4101 + #TRO340.stInSeparator1.Settings.nSeparatorNo := "cSep340.1"; + #TRO340.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO340.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4562"]; + #TRO340.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4570"]; + #TRO340.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4567"]; + #TRO340.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4564"]; + + #TRO340(nInMainTroNo := "cMainTro340", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea340".stJam340_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea340".stJam340_1.stData, + arInOutJamFinger := "DB_JamArea340".stJam340_2.arCarrier, // TODO Topologie + xOutStopper => "MB4562", + xOutVarioMotor => "MA0074", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro340"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO340); + END_REGION + + REGION TRO341 (Vario) — CV-M4102 + #TRO341.stInSeparator1.Settings.nSeparatorNo := "cSep341.1"; + #TRO341.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO341.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4624"]; + #TRO341.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4625"]; + #TRO341.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4623"]; + #TRO341.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4621"]; + + #TRO341(nInMainTroNo := "cMainTro341", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea341".stJam341_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea341".stJam341_1.stData, + arInOutJamFinger := "DB_JamArea341".stJam341_2.arCarrier, // TODO Topologie + xOutStopper => "MB4624", + xOutVarioMotor => "MA0090", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro341"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO341); + END_REGION + + REGION TRO342 (Vario) — CV-M4201 + #TRO342.stInSeparator1.Settings.nSeparatorNo := "cSep342.1"; + #TRO342.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO342.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4572"]; + #TRO342.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4571"]; + #TRO342.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4573"]; + #TRO342.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4563"]; + + #TRO342(nInMainTroNo := "cMainTro342", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea342".stJam342_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea342".stJam342_1.stData, + arInOutJamFinger := "DB_JamArea342".stJam342_2.arCarrier, // TODO Topologie + xOutStopper => "MB4572", + xOutVarioMotor => "MA0075", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro342"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO342); + END_REGION + + REGION TRO343 (Vario) — CV-M4202 + #TRO343.stInSeparator1.Settings.nSeparatorNo := "cSep343.1"; + #TRO343.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO343.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4633"]; + #TRO343.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4635"]; + #TRO343.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4634"]; + #TRO343.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4631"]; + + #TRO343(nInMainTroNo := "cMainTro343", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea343".stJam343_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea343".stJam343_1.stData, + arInOutJamFinger := "DB_JamArea343".stJam343_2.arCarrier, // TODO Topologie + xOutStopper => "MB4633", + xOutVarioMotor => "MA0091", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro343"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO343); + END_REGION + + REGION TRO344 (Vario) — CV-M4301 + #TRO344.stInSeparator1.Settings.nSeparatorNo := "cSep344.1"; + #TRO344.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO344.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4640"]; + #TRO344.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4641"]; + #TRO344.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4642"]; + #TRO344.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4643"]; + + #TRO344(nInMainTroNo := "cMainTro344", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea344".stJam344_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea344".stJam344_1.stData, + arInOutJamFinger := "DB_JamArea344".stJam344_2.arCarrier, // TODO Topologie + xOutStopper => "MB4640", + xOutVarioMotor => "MA0092", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro344"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO344); + END_REGION + + REGION TRO345 (Vario) — CV-M4401 + #TRO345.stInSeparator1.Settings.nSeparatorNo := "cSep345.1"; + #TRO345.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO345.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG4650"]; + #TRO345.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG4651"]; + #TRO345.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG4652"]; + #TRO345.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG4653"]; + + #TRO345(nInMainTroNo := "cMainTro345", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea345".stJam345_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea345".stJam345_1.stData, + arInOutJamFinger := "DB_JamArea345".stJam345_2.arCarrier, // TODO Topologie + xOutStopper => "MB4650", + xOutVarioMotor => "MA0093", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro345"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO345); + END_REGION + +END_FUNCTION_BLOCK diff --git a/results/FB_Main_skel_UH04.scl b/results/FB_Main_skel_UH04.scl new file mode 100644 index 0000000..e3f1ef3 --- /dev/null +++ b/results/FB_Main_skel_UH04.scl @@ -0,0 +1,308 @@ +FUNCTION_BLOCK "FB_Main_skel_UH04" +{ S7_Optimized_Access := 'TRUE' } +VERSION : 0.1 +// ============================================================ +// AUTOMATISCH GENERIERTES GRUNDGERUEST — create_skel.py +// Quelle: E/A-Listen UH04 (data/) +// TODO-Marken kennzeichnen manuell zu ergaenzende Stellen +// (Timings, Topologie/JamAreas, Safety, Release, Priority). +// ============================================================ + VAR + TRO401 : "FB_ILS_MTRO_Vario"; // CV-M0401 + fbConveyor4000 : "FB_Conveyor"; // CV-M4000 + TRO403 : "FB_ILS_MTRO_Vario"; // CV-M4001 + TRO404 : "FB_ILS_MTRO_Vario"; // CV-M4002 + TRO405 : "FB_ILS_MTRO_1Sep1Swi"; // KR-M4003 + TRO406 : "FB_ILS_MTRO_Vario"; // CV-M4004 + TRO407 : "FB_ILS_MTRO_Vario"; // CV-M4005 + TRO408 : "FB_ILS_MTRO_Vario"; // CV-M4006 + TRO409 : "FB_ILS_MTRO_Vario"; // CV-M4007 + TRO410 : "FB_ILS_MTRO_Vario"; // CV-M4008 + TRO411 : "FB_ILS_MTRO_Vario"; // CV-M4009 + TRO412 : "FB_ILS_MTRO_Vario"; // CV-M4010 + TRO413 : "FB_ILS_MTRO_Vario"; // CV-M4011 + END_VAR + +BEGIN + REGION TRO401 (Vario) — CV-M0401 + #TRO401.stInSeparator1.Settings.nSeparatorNo := "cSep401.1"; + #TRO401.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO401.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3260"]; + #TRO401.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3261"]; + #TRO401.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3262"]; + #TRO401.stInVario.stSenJam := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO401(nInMainTroNo := "cMainTro401", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea401".stJam401_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea401".stJam401_1.stData, + arInOutJamFinger := "DB_JamArea401".stJam401_2.arCarrier, // TODO Topologie + xOutStopper => "MB3260", + xOutVarioMotor => "MAxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro401"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO401); + END_REGION + + REGION fbConveyor4000 — CV-M4000 + #fbConveyor4000.Settings.tEnergySafeTime := "cTimeEnergySafe"; + #fbConveyor4000.Settings.xGridActive := FALSE; // TODO Grid + #fbConveyor4000.Settings.sMotorProtectName := 'FCxxxx'; + + #fbConveyor4000(xInEnabled := TRUE, // TODO Enable + xInMotorProtection := "FCxxxx", + xInPowerContactor := "MA0070", + stInOutHMI := "DB_Interface_HMI".stConveyors.fbConveyor4000); + END_REGION + + REGION TRO403 (Vario) — CV-M4001 + #TRO403.stInSeparator1.Settings.nSeparatorNo := "cSep403.1"; + #TRO403.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO403.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3242"]; + #TRO403.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO403.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3244"]; + #TRO403.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3246"]; + + #TRO403(nInMainTroNo := "cMainTro403", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea403".stJam403_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea403".stJam403_1.stData, + arInOutJamFinger := "DB_JamArea403".stJam403_2.arCarrier, // TODO Topologie + xOutStopper => "MB3242", + xOutVarioMotor => "MA0071", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro403"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO403); + END_REGION + + REGION TRO404 (Vario) — CV-M4002 + #TRO404.stInSeparator1.Settings.nSeparatorNo := "cSep404.1"; + #TRO404.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO404.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3386"]; + #TRO404.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3426"]; + #TRO404.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3421"]; + #TRO404.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3387"]; + + #TRO404(nInMainTroNo := "cMainTro404", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea404".stJam404_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea404".stJam404_1.stData, + arInOutJamFinger := "DB_JamArea404".stJam404_2.arCarrier, // TODO Topologie + xOutStopper => "MB3386", + xOutVarioMotor => "MA0073", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro404"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO404); + END_REGION + + REGION TRO405 (1Sep1Swi) — KR-M4003 + #TRO405.stInSeparator1.Settings.nSeparatorNo := "cSep405.1"; + #TRO405.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO405.stInSeparator1.Settings.tTrailingTime := T#100ms; // TODO Timing + #TRO405.stInSeparator1.Settings.tHandlingTime := T#50ms; // TODO Timing + #TRO405.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO405.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3300"]; + #TRO405.stInSenJam2 := "DB_Inputs".Sensors["cInBG3301"]; + #TRO405.stInSwitch1.Settings.nSwitchNo := "cSwi405.1"; + + #TRO405(nInMainTroNo := "cMainTro405", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun1 := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea405".stJam405_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea405".stJam405_1.stData, + arInOutJamExit2 := "DB_JamArea405".stJam405_2.arCarrier, // TODO Topologie (Dir1) + stInOutJamExit2 := "DB_JamArea405".stJam405_2.stData, + arInOutJamExit3 := "DB_JamArea405".stJam405_3.arCarrier, // TODO Topologie (Dir2) + stInOutJamExit3 := "DB_JamArea405".stJam405_3.stData, + xOutStopper1 => "MB3300", + xOutSw1ExTo3 => "MB3362", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro405"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO405); + END_REGION + + REGION TRO406 (Vario) — CV-M4004 + #TRO406.stInSeparator1.Settings.nSeparatorNo := "cSep406.1"; + #TRO406.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO406.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO406.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3316"]; + #TRO406.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3312"]; + #TRO406.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3311"]; + + #TRO406(nInMainTroNo := "cMainTro406", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea406".stJam406_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea406".stJam406_1.stData, + arInOutJamFinger := "DB_JamArea406".stJam406_2.arCarrier, // TODO Topologie + xOutStopper => "MBxxxx", + xOutVarioMotor => "MA0061", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro406"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO406); + END_REGION + + REGION TRO407 (Vario) — CV-M4005 + #TRO407.stInSeparator1.Settings.nSeparatorNo := "cSep407.1"; + #TRO407.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO407.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3321"]; + #TRO407.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3314"]; + #TRO407.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3315"]; + #TRO407.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3320"]; + + #TRO407(nInMainTroNo := "cMainTro407", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea407".stJam407_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea407".stJam407_1.stData, + arInOutJamFinger := "DB_JamArea407".stJam407_2.arCarrier, // TODO Topologie + xOutStopper => "MB3321", + xOutVarioMotor => "MA0062", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro407"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO407); + END_REGION + + REGION TRO408 (Vario) — CV-M4006 + #TRO408.stInSeparator1.Settings.nSeparatorNo := "cSep408.1"; + #TRO408.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO408.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3370"]; + #TRO408.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3376"]; + #TRO408.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3372"]; + #TRO408.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3371"]; + + #TRO408(nInMainTroNo := "cMainTro408", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea408".stJam408_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea408".stJam408_1.stData, + arInOutJamFinger := "DB_JamArea408".stJam408_2.arCarrier, // TODO Topologie + xOutStopper => "MB3370", + xOutVarioMotor => "MA0063", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro408"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO408); + END_REGION + + REGION TRO409 (Vario) — CV-M4007 + #TRO409.stInSeparator1.Settings.nSeparatorNo := "cSep409.1"; + #TRO409.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO409.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3381"]; + #TRO409.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3374"]; + #TRO409.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3375"]; + #TRO409.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3380"]; + + #TRO409(nInMainTroNo := "cMainTro409", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea409".stJam409_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea409".stJam409_1.stData, + arInOutJamFinger := "DB_JamArea409".stJam409_2.arCarrier, // TODO Topologie + xOutStopper => "MB3381", + xOutVarioMotor => "MA0064", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro409"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO409); + END_REGION + + REGION TRO410 (Vario) — CV-M4008 + #TRO410.stInSeparator1.Settings.nSeparatorNo := "cSep410.1"; + #TRO410.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO410.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3440"]; + #TRO410.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3446"]; + #TRO410.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3442"]; + #TRO410.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3437"]; + + #TRO410(nInMainTroNo := "cMainTro410", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea410".stJam410_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea410".stJam410_1.stData, + arInOutJamFinger := "DB_JamArea410".stJam410_2.arCarrier, // TODO Topologie + xOutStopper => "MB3440", + xOutVarioMotor => "MA0065", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro410"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO410); + END_REGION + + REGION TRO411 (Vario) — CV-M4009 + #TRO411.stInSeparator1.Settings.nSeparatorNo := "cSep411.1"; + #TRO411.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO411.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3436"]; + #TRO411.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3444"]; + #TRO411.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3445"]; + #TRO411.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3431"]; + + #TRO411(nInMainTroNo := "cMainTro411", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea411".stJam411_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea411".stJam411_1.stData, + arInOutJamFinger := "DB_JamArea411".stJam411_2.arCarrier, // TODO Topologie + xOutStopper => "MB3436", + xOutVarioMotor => "MA0066", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro411"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO411); + END_REGION + + REGION TRO412 (Vario) — CV-M4010 + #TRO412.stInSeparator1.Settings.nSeparatorNo := "cSep412.1"; + #TRO412.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO412.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3391"]; + #TRO412.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3392"]; + #TRO412.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3393"]; + #TRO412.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3423"]; + + #TRO412(nInMainTroNo := "cMainTro412", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea412".stJam412_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea412".stJam412_1.stData, + arInOutJamFinger := "DB_JamArea412".stJam412_2.arCarrier, // TODO Topologie + xOutStopper => "MB3391", + xOutVarioMotor => "MA0074", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro412"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO412); + END_REGION + + REGION TRO413 (Vario) — CV-M4011 + #TRO413.stInSeparator1.Settings.nSeparatorNo := "cSep413.1"; + #TRO413.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO413.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3250"]; + #TRO413.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3255"]; + #TRO413.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3253"]; + #TRO413.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3264"]; + + #TRO413(nInMainTroNo := "cMainTro413", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea413".stJam413_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea413".stJam413_1.stData, + arInOutJamFinger := "DB_JamArea413".stJam413_2.arCarrier, // TODO Topologie + xOutStopper => "MB3250", + xOutVarioMotor => "MA0072", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro413"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO413); + END_REGION + +END_FUNCTION_BLOCK diff --git a/results/FB_Main_skel_UH05.scl b/results/FB_Main_skel_UH05.scl new file mode 100644 index 0000000..1502259 --- /dev/null +++ b/results/FB_Main_skel_UH05.scl @@ -0,0 +1,379 @@ +FUNCTION_BLOCK "FB_Main_skel_UH05" +{ S7_Optimized_Access := 'TRUE' } +VERSION : 0.1 +// ============================================================ +// AUTOMATISCH GENERIERTES GRUNDGERUEST — create_skel.py +// Quelle: E/A-Listen UH05 (data/) +// TODO-Marken kennzeichnen manuell zu ergaenzende Stellen +// (Timings, Topologie/JamAreas, Safety, Release, Priority). +// ============================================================ + VAR + TRO501 : "FB_ILS_MTRO_1Sep"; // KR-M0500 + TRO502 : "FB_ILS_MTRO_1Sep"; // CV-M0510 + TRO503 : "FB_ILS_MTRO_1Sep"; // CV-M5000 + TRO504 : "FB_ILS_MTRO_Vario"; // CV-M5000_A + TRO505 : "FB_ILS_MTRO_Vario"; // CV-M5000_B + TRO506 : "FB_ILS_MTRO_1Sep"; // CV-M5001 + TRO507 : "FB_ILS_MTRO_Vario"; // CV-M5001_A + TRO508 : "FB_ILS_MTRO_Vario"; // CV-M5001_B + TRO509 : "FB_ILS_MTRO_1Sep"; // KR-M5002 + TRO510 : "FB_ILS_MTRO_Vario"; // CV-M5003 / WS1.1 + TRO511 : "FB_ILS_MTRO_Vario"; // CV-M5004 / WS1.1 + TRO512 : "FB_ILS_MTRO_Vario"; // CV-M5005 / WS1.0 + TRO513 : "FB_ILS_MTRO_Vario"; // CV-M5006 / WS2.0 + TRO514 : "FB_ILS_MTRO_Vario"; // CV-M5007 / WS3.0 + TRO515 : "FB_ILS_MTRO_Vario"; // CV-M5008 / WS4.0 + END_VAR + +BEGIN + REGION TRO501 (1Sep) — KR-M0500 + #TRO501.stInSeparator1.Settings.nSeparatorNo := "cSep501.1"; + #TRO501.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO501.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO501.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO501.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO501.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3372"]; + #TRO501.stInSenJam2 := "DB_Inputs".Sensors["cInBG3431"]; + + #TRO501.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO501(nInMainTroNo := "cMainTro501", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea501".stJam501_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea501".stJam501_1.stData, + arInOutJamExit2 := "DB_JamArea501".stJam501_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea501".stJam501_2.stData, + xOutStopper1 => "MB3372", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro501"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO501); + END_REGION + + REGION TRO502 (1Sep) — CV-M0510 + #TRO502.stInSeparator1.Settings.nSeparatorNo := "cSep502.1"; + #TRO502.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO502.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO502.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO502.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO502.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3330"]; + #TRO502.stInSenJam2 := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO502.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO502(nInMainTroNo := "cMainTro502", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea502".stJam502_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea502".stJam502_1.stData, + arInOutJamExit2 := "DB_JamArea502".stJam502_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea502".stJam502_2.stData, + xOutStopper1 => "MBxxxx", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro502"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO502); + END_REGION + + REGION TRO503 (1Sep) — CV-M5000 + #TRO503.stInSeparator1.Settings.nSeparatorNo := "cSep503.1"; + #TRO503.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO503.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO503.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO503.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO503.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3301"]; + #TRO503.stInSenJam2 := "DB_Inputs".Sensors["cInBG3310"]; + + #TRO503.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO503(nInMainTroNo := "cMainTro503", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea503".stJam503_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea503".stJam503_1.stData, + arInOutJamExit2 := "DB_JamArea503".stJam503_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea503".stJam503_2.stData, + xOutStopper1 => "MB3301", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro503"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO503); + END_REGION + + REGION TRO504 (Vario) — CV-M5000_A + #TRO504.stInSeparator1.Settings.nSeparatorNo := "cSep504.1"; + #TRO504.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO504.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBGxxxx"]; + #TRO504.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3332"]; + #TRO504.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3331"]; + #TRO504.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3451"]; + + #TRO504(nInMainTroNo := "cMainTro504", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea504".stJam504_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea504".stJam504_1.stData, + arInOutJamFinger := "DB_JamArea504".stJam504_2.arCarrier, // TODO Topologie + xOutStopper => "MB3330", + xOutVarioMotor => "MA0071", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro504"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO504); + END_REGION + + REGION TRO505 (Vario) — CV-M5000_B + #TRO505.stInSeparator1.Settings.nSeparatorNo := "cSep505.1"; + #TRO505.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO505.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3452"]; + #TRO505.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3454"]; + #TRO505.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3453"]; + #TRO505.stInVario.stSenJam := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO505(nInMainTroNo := "cMainTro505", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea505".stJam505_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea505".stJam505_1.stData, + arInOutJamFinger := "DB_JamArea505".stJam505_2.arCarrier, // TODO Topologie + xOutStopper => "MB3452", + xOutVarioMotor => "MA0060", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro505"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO505); + END_REGION + + REGION TRO506 (1Sep) — CV-M5001 + #TRO506.stInSeparator1.Settings.nSeparatorNo := "cSep506.1"; + #TRO506.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO506.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO506.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO506.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO506.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3304"]; + #TRO506.stInSenJam2 := "DB_Inputs".Sensors["cInBG3305"]; + + #TRO506.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO506(nInMainTroNo := "cMainTro506", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea506".stJam506_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea506".stJam506_1.stData, + arInOutJamExit2 := "DB_JamArea506".stJam506_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea506".stJam506_2.stData, + xOutStopper1 => "MB3304", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro506"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO506); + END_REGION + + REGION TRO507 (Vario) — CV-M5001_A + #TRO507.stInSeparator1.Settings.nSeparatorNo := "cSep507.1"; + #TRO507.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO507.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3333"]; + #TRO507.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3335"]; + #TRO507.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3334"]; + #TRO507.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3456"]; + + #TRO507(nInMainTroNo := "cMainTro507", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea507".stJam507_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea507".stJam507_1.stData, + arInOutJamFinger := "DB_JamArea507".stJam507_2.arCarrier, // TODO Topologie + xOutStopper => "MB3333", + xOutVarioMotor => "MA0072", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro507"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO507); + END_REGION + + REGION TRO508 (Vario) — CV-M5001_B + #TRO508.stInSeparator1.Settings.nSeparatorNo := "cSep508.1"; + #TRO508.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO508.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3457"]; + #TRO508.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3461"]; + #TRO508.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3460"]; + #TRO508.stInVario.stSenJam := "DB_Inputs".Sensors["cInBGxxxx"]; + + #TRO508(nInMainTroNo := "cMainTro508", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea508".stJam508_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea508".stJam508_1.stData, + arInOutJamFinger := "DB_JamArea508".stJam508_2.arCarrier, // TODO Topologie + xOutStopper => "MB3457", + xOutVarioMotor => "MA0061", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro508"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO508); + END_REGION + + REGION TRO509 (1Sep) — KR-M5002 + #TRO509.stInSeparator1.Settings.nSeparatorNo := "cSep509.1"; + #TRO509.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO509.stInSeparator1.Settings.tTrailingTime := T#500ms; // TODO Timing + #TRO509.stInSeparator1.Settings.tHandlingTime := T#200ms; // TODO Timing + #TRO509.stInSeparator1.Settings.tJam := "TimeForSepJam"; + #TRO509.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3240"]; + #TRO509.stInSenJam2 := "DB_Inputs".Sensors["cInBG3241"]; + + #TRO509.stInPriorityManager.xReleaseOk := TRUE; // TODO Priority + + #TRO509(nInMainTroNo := "cMainTro509", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInCarouselRun := TRUE, // TODO Conveyor + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea509".stJam509_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea509".stJam509_1.stData, + arInOutJamExit2 := "DB_JamArea509".stJam509_2.arCarrier, // TODO Topologie + stInOutJamExit2 := "DB_JamArea509".stJam509_2.stData, + xOutStopper1 => "MB3240", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro509"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO509); + END_REGION + + REGION TRO510 (Vario) — CV-M5003 / WS1.1 + #TRO510.stInSeparator1.Settings.nSeparatorNo := "cSep510.1"; + #TRO510.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO510.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3245"]; + #TRO510.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3244"]; + #TRO510.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3246"]; + #TRO510.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3243"]; + + #TRO510(nInMainTroNo := "cMainTro510", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea510".stJam510_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea510".stJam510_1.stData, + arInOutJamFinger := "DB_JamArea510".stJam510_2.arCarrier, // TODO Topologie + xOutStopper => "MB3245", + xOutVarioMotor => "MA0063", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro510"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO510); + END_REGION + + REGION TRO511 (Vario) — CV-M5004 / WS1.1 + #TRO511.stInSeparator1.Settings.nSeparatorNo := "cSep511.1"; + #TRO511.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO511.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3251"]; + #TRO511.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3255"]; + #TRO511.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3254"]; + #TRO511.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3252"]; + + #TRO511(nInMainTroNo := "cMainTro511", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea511".stJam511_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea511".stJam511_1.stData, + arInOutJamFinger := "DB_JamArea511".stJam511_2.arCarrier, // TODO Topologie + xOutStopper => "MB3251", + xOutVarioMotor => "MA0064", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro511"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO511); + END_REGION + + REGION TRO512 (Vario) — CV-M5005 / WS1.0 + #TRO512.stInSeparator1.Settings.nSeparatorNo := "cSep512.1"; + #TRO512.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO512.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3314"]; + #TRO512.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3320"]; + #TRO512.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3317"]; + #TRO512.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3313"]; + + #TRO512(nInMainTroNo := "cMainTro512", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea512".stJam512_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea512".stJam512_1.stData, + arInOutJamFinger := "DB_JamArea512".stJam512_2.arCarrier, // TODO Topologie + xOutStopper => "MB3314", + xOutVarioMotor => "MA0065", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro512"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO512); + END_REGION + + REGION TRO513 (Vario) — CV-M5006 / WS2.0 + #TRO513.stInSeparator1.Settings.nSeparatorNo := "cSep513.1"; + #TRO513.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO513.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3362"]; + #TRO513.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3366"]; + #TRO513.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3365"]; + #TRO513.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3361"]; + + #TRO513(nInMainTroNo := "cMainTro513", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea513".stJam513_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea513".stJam513_1.stData, + arInOutJamFinger := "DB_JamArea513".stJam513_2.arCarrier, // TODO Topologie + xOutStopper => "MB3362", + xOutVarioMotor => "MA0066", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro513"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO513); + END_REGION + + REGION TRO514 (Vario) — CV-M5007 / WS3.0 + #TRO514.stInSeparator1.Settings.nSeparatorNo := "cSep514.1"; + #TRO514.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO514.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3374"]; + #TRO514.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3380"]; + #TRO514.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3377"]; + #TRO514.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3373"]; + + #TRO514(nInMainTroNo := "cMainTro514", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea514".stJam514_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea514".stJam514_1.stData, + arInOutJamFinger := "DB_JamArea514".stJam514_2.arCarrier, // TODO Topologie + xOutStopper => "MB3374", + xOutVarioMotor => "MA0067", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro514"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO514); + END_REGION + + REGION TRO515 (Vario) — CV-M5008 / WS4.0 + #TRO515.stInSeparator1.Settings.nSeparatorNo := "cSep515.1"; + #TRO515.stInSeparator1.Settings.tDelayToNextItem := "TimeForSepWaiting_Short"; + #TRO515.stInSeparator1.stSenInSep := "DB_Inputs".Sensors["cInBG3422"]; + #TRO515.stInVario.stSenCarrInPos := "DB_Inputs".Sensors["cInBG3426"]; + #TRO515.stInVario.stSenFinger := "DB_Inputs".Sensors["cInBG3425"]; + #TRO515.stInVario.stSenJam := "DB_Inputs".Sensors["cInBG3421"]; + + #TRO515(nInMainTroNo := "cMainTro515", + xInSftyOk := TRUE, // TODO Safety + xInAllRdyToStart := TRUE, + xInRelease := TRUE, // TODO Release + stInOutMachineState := #stInOutControlUnit, // TODO ControlUnit + arInOutJamEntr1 := "DB_JamArea515".stJam515_1.arCarrier, // TODO Topologie + stInOutJamEntr1 := "DB_JamArea515".stJam515_1.stData, + arInOutJamFinger := "DB_JamArea515".stJam515_2.arCarrier, // TODO Topologie + xOutStopper => "MB3422", + xOutVarioMotor => "MA0070", + nOutStateLast => "DB_GLOB_TroState".arTroState["cMainTro515"], + stInOutHMI := "DB_Interface_HMI".stTRO.TRO515); + END_REGION + +END_FUNCTION_BLOCK diff --git a/results/skeleton_UH01.json b/results/skeleton_UH01.json new file mode 100644 index 0000000..c70b34d --- /dev/null +++ b/results/skeleton_UH01.json @@ -0,0 +1,5840 @@ +{ + "$schema": "hmf-layout-v1.schema.json", + "generatedBy": "create_skel.py", + "plc": { + "id": "UH01", + "configName": "=A01+UH01-KF00" + }, + "statistics": { + "tags": 443, + "sensors": 287, + "constants": 443, + "units": 29, + "areas": 14, + "unassignedSignals": 99, + "troNodes": 36, + "connections": 37, + "externals": 4 + }, + "sensors": [ + { + "id": "SF0000", + "constant": "cInSF0000", + "hwAddress": "%E000.0", + "comment": "DT Anlage Aus", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 145855.2 + ] + }, + { + "id": "SF0001", + "constant": "cInSF0001", + "hwAddress": "%E000.1", + "comment": "LDT Anlage Ein", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 145585.2 + ] + }, + { + "id": "SF0002", + "constant": "cInSF0002", + "hwAddress": "%E000.2", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 145315.2 + ] + }, + { + "id": "SF0003", + "constant": "cInSF0003", + "hwAddress": "%E000.3", + "comment": "DT Lampentest", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 145045.2 + ] + }, + { + "id": "BP0004", + "constant": "cInBP0004", + "hwAddress": "%E000.4", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UH01", + "pos": [ + 328638.1, + 149936.1 + ] + }, + { + "id": "DI0005", + "constant": "cInDI0005", + "hwAddress": "%E000.5", + "comment": "Phasenausfall 400V", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 141779.9 + ] + }, + { + "id": "DI0006", + "constant": "cInDI0006", + "hwAddress": "%E000.6", + "comment": "Vorsicherung 400V UC0110", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 141509.9 + ] + }, + { + "id": "DI0007", + "constant": "cInDI0007", + "hwAddress": "%E000.7", + "comment": "Vorsicherung 400V UC0111", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 141239.9 + ] + }, + { + "id": "DI0010", + "constant": "cInDI0010", + "hwAddress": "%E001.0", + "comment": "Vorsicherung 400V UC011", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 140969.9 + ] + }, + { + "id": "DI0011", + "constant": "cInDI0011", + "hwAddress": "%E001.1", + "comment": "Feedback Hauptschütze aktiv +UC0110", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 134559.7 + ] + }, + { + "id": "DI0012", + "constant": "cInDI0012", + "hwAddress": "%E001.2", + "comment": "Feedback Hauptschütze aktiv +UC0111", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 133619.8 + ] + }, + { + "id": "DI0013", + "constant": "cInDI0013", + "hwAddress": "%E001.3", + "comment": "Feedback Hauptschütze aktiv", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 137170.9 + ] + }, + { + "id": "DI0014", + "constant": "cInDI0014", + "hwAddress": "%E001.4", + "comment": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 136225.9 + ] + }, + { + "id": "DI0016", + "constant": "cInDI0016", + "hwAddress": "%E001.6", + "comment": "Vorsicherung 400V", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 140649.8 + ] + }, + { + "id": "DI0017", + "constant": "cInDI0017", + "hwAddress": "%E001.7", + "comment": "Sicherung Lampe 1EA0012 & 1EA0013", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 140379.8 + ] + }, + { + "id": "DI0021", + "constant": "cInDI0021", + "hwAddress": "%E002.1", + "comment": "Vorsicherung 24V OK (FC021)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 140055.7 + ] + }, + { + "id": "DI0022", + "constant": "cInDI0022", + "hwAddress": "%E002.2", + "comment": "Vorsicherung 24V OK (FC022)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 139785.7 + ] + }, + { + "id": "DI0023", + "constant": "cInDI0023", + "hwAddress": "%E002.3", + "comment": "Vorsicherung 24V OK (FC023)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 139515.7 + ] + }, + { + "id": "DI0024", + "constant": "cInDI0024", + "hwAddress": "%E002.4", + "comment": "Vorsicherung 24V OK (FC024)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 139245.7 + ] + }, + { + "id": "SF0025", + "constant": "cInSF0025", + "hwAddress": "%E002.5", + "comment": "Schlüsselschalter LS 1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 144775.2 + ] + }, + { + "id": "SF0026", + "constant": "cInSF0026", + "hwAddress": "%E002.6", + "comment": "Schlüsselschalter LS 2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 144505.2 + ] + }, + { + "id": "SF0031", + "constant": "cInSF0031", + "hwAddress": "%E003.1", + "comment": "Reset UZ0101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 335107.8, + 169990.9 + ] + }, + { + "id": "SF0032", + "constant": "cInSF0032", + "hwAddress": "%E003.2", + "comment": "Freigabe UZ0102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 324061.5, + 151394.7 + ] + }, + { + "id": "SF0033", + "constant": "cInSF0033", + "hwAddress": "%E003.3", + "comment": "Reset UZ0102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 324061.5, + 151124.7 + ] + }, + { + "id": "DI0034", + "constant": "cInDI0034", + "hwAddress": "%E003.4", + "comment": "IF BMZ \"fire alarm\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 328024.6, + 130120.5 + ] + }, + { + "id": "DI0035", + "constant": "cInDI0035", + "hwAddress": "%E003.5", + "comment": "IF BST \"No fire alarm\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 138916.2 + ] + }, + { + "id": "DI0036", + "constant": "cInDI0036", + "hwAddress": "%E003.6", + "comment": "IF BST \"Non fault\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 138646.2 + ] + }, + { + "id": "DI0037", + "constant": "cInDI0037", + "hwAddress": "%E003.7", + "comment": "IF BST \"FPC opened\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 138376.2 + ] + }, + { + "id": "SF0041", + "constant": "cInSF0041", + "hwAddress": "%E004.1", + "comment": "Strahler ein/aus LS1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 333191.0, + 150479.2 + ] + }, + { + "id": "DI0042", + "constant": "cInDI0042", + "hwAddress": "%E004.2", + "comment": "Schnittstelle RFID (from Rielec \"station ready\")", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "SF0043", + "constant": "cInSF0043", + "hwAddress": "%E004.3", + "comment": "Reset LS1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 333191.0, + 149500.4 + ] + }, + { + "id": "SF0044", + "constant": "cInSF0044", + "hwAddress": "%E004.4", + "comment": "Ladeschleife aktivieren LS1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 333191.0, + 149840.4 + ] + }, + { + "id": "SF0046", + "constant": "cInSF0046", + "hwAddress": "%E004.6", + "comment": "Strahler ein/aus LS2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 336293.3, + 150479.2 + ] + }, + { + "id": "DI0047", + "constant": "cInDI0047", + "hwAddress": "%E004.7", + "comment": "Schnittstelle RFID (from Rielec \"bypass mode\")", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "SF0050", + "constant": "cInSF0050", + "hwAddress": "%E005.0", + "comment": "Positionsschalter Ladeschleife 1 eingefahren", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 370715.4, + 178888.7 + ] + }, + { + "id": "SF0051", + "constant": "cInSF0051", + "hwAddress": "%E005.1", + "comment": "Positionsschalter Ladeschleife 1 ausgefahren", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 370715.4, + 179158.7 + ] + }, + { + "id": "SF0052", + "constant": "cInSF0052", + "hwAddress": "%E005.2", + "comment": "Positionsschalter Ladeschleife 2 eingefahren", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "SF0053", + "constant": "cInSF0053", + "hwAddress": "%E005.3", + "comment": "Positionsschalter Ladeschleife 2 ausgefahren", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "SF0054", + "constant": "cInSF0054", + "hwAddress": "%E005.4", + "comment": "Reset LS2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 336293.3, + 149500.4 + ] + }, + { + "id": "SF0055", + "constant": "cInSF0055", + "hwAddress": "%E005.5", + "comment": "Ladeschleife aktivieren LS2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 336293.3, + 149840.4 + ] + }, + { + "id": "FC0057", + "constant": "cInFC0057", + "hwAddress": "%E005.7", + "comment": "MSS ausgelöst FC0057 (ILS-CVM0100)", + "role": "motorProtection", + "unit": "M0100", + "cabinet": null, + "pos": [ + 327898.7, + 132441.4 + ] + }, + { + "id": "FC0060", + "constant": "cInFC0060", + "hwAddress": "%E006.0", + "comment": "MSS ausgelöst FC0060 (ILS-KR-M0101)", + "role": "motorProtection", + "unit": "M0101", + "cabinet": null, + "pos": [ + 327898.7, + 132171.4 + ] + }, + { + "id": "FC0061", + "constant": "cInFC0061", + "hwAddress": "%E006.1", + "comment": "MSS ausgelöst FC0061 (ILS-KR-M0102) Auslagerkreisel", + "role": "motorProtection", + "unit": "M0102", + "cabinet": null, + "pos": [ + 327898.7, + 131901.4 + ] + }, + { + "id": "FC0062", + "constant": "cInFC0062", + "hwAddress": "%E006.2", + "comment": "MSS ausgelöst FC0062 (ILS-CV-M0103)", + "role": "motorProtection", + "unit": "M0103", + "cabinet": null, + "pos": [ + 327898.7, + 131631.4 + ] + }, + { + "id": "FC0063", + "constant": "cInFC0063", + "hwAddress": "%E006.3", + "comment": "MSS ausgelöst FC0063 (ILS-CV-M0105)", + "role": "motorProtection", + "unit": "M0105", + "cabinet": null, + "pos": [ + 327898.7, + 131361.4 + ] + }, + { + "id": "FC0064", + "constant": "cInFC0064", + "hwAddress": "%E006.4", + "comment": "MSS ausgelöst FC0064 (ILS-CV M0106)", + "role": "motorProtection", + "unit": "M0106", + "cabinet": null, + "pos": [ + 330179.0, + 132367.5 + ] + }, + { + "id": "FC0065", + "constant": "cInFC0065", + "hwAddress": "%E006.5", + "comment": "MSS ausgelöst FC0065 (ILS-CV M0107)", + "role": "motorProtection", + "unit": "M0107", + "cabinet": null, + "pos": [ + 330179.6, + 132097.5 + ] + }, + { + "id": "FC0066", + "constant": "cInFC0066", + "hwAddress": "%E006.6", + "comment": "MSS ausgelöst FC0066 (ILS-CV M0109)", + "role": "motorProtection", + "unit": "M0109", + "cabinet": null, + "pos": [ + 330198.7, + 131833.0 + ] + }, + { + "id": "FC0067", + "constant": "cInFC0067", + "hwAddress": "%E006.7", + "comment": "MSS ausgelöst FC0067 (ILS-CV M0110)", + "role": "motorProtection", + "unit": "M0110", + "cabinet": null, + "pos": [ + 330187.6, + 131557.5 + ] + }, + { + "id": "FC0070", + "constant": "cInFC0070", + "hwAddress": "%E007.0", + "comment": "MSS ausgelöst FC0070", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 370718.9, + 181454.1 + ] + }, + { + "id": "FC0072", + "constant": "cInFC0072", + "hwAddress": "%E007.2", + "comment": "MSS ausgelöst FC0072", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 370718.9, + 180570.0 + ] + }, + { + "id": "FC0074", + "constant": "cInFC0074", + "hwAddress": "%E007.4", + "comment": "MSS ausgelöst FC0074", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 376718.9, + 181454.1 + ] + }, + { + "id": "FC0076", + "constant": "cInFC0076", + "hwAddress": "%E007.6", + "comment": "MSS ausgelöst FC0076", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 376718.9, + 180570.0 + ] + }, + { + "id": "DI0100", + "constant": "cInDI0100", + "hwAddress": "%E010.0", + "comment": "Meldekontakt 400V Motor+Bremse", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 329462.4, + 457182.0 + ] + }, + { + "id": "DI0101", + "constant": "cInDI0101", + "hwAddress": "%E010.1", + "comment": "Vorsicherung 24V OK (FC101)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 329462.4, + 456912.0 + ] + }, + { + "id": "DI0102", + "constant": "cInDI0102", + "hwAddress": "%E010.2", + "comment": "Vorsicherung 24V OK (FC102)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 329462.4, + 456642.0 + ] + }, + { + "id": "DI0106", + "constant": "cInDI0106", + "hwAddress": "%E010.6", + "comment": "Feedback Hauptschütze aktiv (QA0920/QA0921)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 329462.4, + 455995.4 + ] + }, + { + "id": "BP0107", + "constant": "cInBP0107", + "hwAddress": "%E010.7", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UC011", + "pos": [ + 334538.1, + 450099.7 + ] + }, + { + "id": "DI0110", + "constant": "cInDI0110", + "hwAddress": "%E011.0", + "comment": "IF BST \"No fire alarm\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 360742.3, + 457084.7 + ] + }, + { + "id": "DI0111", + "constant": "cInDI0111", + "hwAddress": "%E011.1", + "comment": "IF BST \"Non fault\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 360742.3, + 456814.7 + ] + }, + { + "id": "DI0112", + "constant": "cInDI0112", + "hwAddress": "%E011.2", + "comment": "IF BST \"FPC opened\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 360742.3, + 456544.7 + ] + }, + { + "id": "DI0114", + "constant": "cInDI0114", + "hwAddress": "%E011.4", + "comment": "Feedback Koppelrelais E-Stop-IF (QA0922/QA0923)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 329462.4, + 455115.5 + ] + }, + { + "id": "SF0117", + "constant": "cInSF0117", + "hwAddress": "%E011.7", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 329344.4, + 459232.9 + ] + }, + { + "id": "SF0120", + "constant": "cInSF0120", + "hwAddress": "%E012.0", + "comment": "Bereichshalt UZ1101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 334976.7, + 453451.1 + ] + }, + { + "id": "SF0121", + "constant": "cInSF0121", + "hwAddress": "%E012.1", + "comment": "Reset UZ1101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 334976.7, + 453181.1 + ] + }, + { + "id": "SF0124", + "constant": "cInSF0124", + "hwAddress": "%E012.4", + "comment": "Bereichshalt UZ1103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 328664.8, + 450445.2 + ] + }, + { + "id": "SF0125", + "constant": "cInSF0125", + "hwAddress": "%E012.5", + "comment": "Reset UZ1103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 328664.8, + 450175.2 + ] + }, + { + "id": "SF0126", + "constant": "cInSF0126", + "hwAddress": "%E012.6", + "comment": "Bereichshalt UZ1104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 313036.3, + 450452.7 + ] + }, + { + "id": "SF0127", + "constant": "cInSF0127", + "hwAddress": "%E012.7", + "comment": "Reset UZ1104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 313036.3, + 450182.7 + ] + }, + { + "id": "SF0130", + "constant": "cInSF0130", + "hwAddress": "%E013.0", + "comment": "Bereichshalt UZ1105", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 299080.7, + 450481.9 + ] + }, + { + "id": "SF0131", + "constant": "cInSF0131", + "hwAddress": "%E013.1", + "comment": "Reset UZ1105", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 299080.7, + 450211.9 + ] + }, + { + "id": "FC0140", + "constant": "cInFC0140", + "hwAddress": "%E014.0", + "comment": "MSS ausgelöst FC0140 (KR-M4204)", + "role": "motorProtection", + "unit": "M4204", + "cabinet": null, + "pos": [ + 329374.5, + 453500.1 + ] + }, + { + "id": "FC0141", + "constant": "cInFC0141", + "hwAddress": "%E014.1", + "comment": "MSS ausgelöst FC0141 (CV-M4503)", + "role": "motorProtection", + "unit": "M4503", + "cabinet": null, + "pos": [ + 329374.5, + 453230.1 + ] + }, + { + "id": "FC0142", + "constant": "cInFC0142", + "hwAddress": "%E014.2", + "comment": "MSS ausgelöst FC0142 (CV-M4502)", + "role": "motorProtection", + "unit": "M4502", + "cabinet": null, + "pos": [ + 329374.5, + 452960.1 + ] + }, + { + "id": "FC0143", + "constant": "cInFC0143", + "hwAddress": "%E014.3", + "comment": "MSS ausgelöst FC0143 (CV-M4403)", + "role": "motorProtection", + "unit": "M4403", + "cabinet": null, + "pos": [ + 329374.5, + 452690.1 + ] + }, + { + "id": "FC0144", + "constant": "cInFC0144", + "hwAddress": "%E014.4", + "comment": "MSS ausgelöst FC0144 (CV-M4501)", + "role": "motorProtection", + "unit": "M4501", + "cabinet": null, + "pos": [ + 329370.7, + 452418.5 + ] + }, + { + "id": "FC0145", + "constant": "cInFC0145", + "hwAddress": "%E014.5", + "comment": "MSS ausgelöst FC0145 (CV-M4104)", + "role": "motorProtection", + "unit": "M4104", + "cabinet": null, + "pos": [ + 329374.5, + 452150.1 + ] + }, + { + "id": "FC0146", + "constant": "cInFC0146", + "hwAddress": "%E014.6", + "comment": "MSS ausgelöst FC0146 (CV-M4103)", + "role": "motorProtection", + "unit": "M4103", + "cabinet": null, + "pos": [ + 329374.5, + 451880.1 + ] + }, + { + "id": "FC0147", + "constant": "cInFC0147", + "hwAddress": "%E014.7", + "comment": "MSS ausgelöst FC0147 (CV-M4203_A)", + "role": "motorProtection", + "unit": "M4203_A", + "cabinet": null, + "pos": [ + 329374.5, + 451610.1 + ] + }, + { + "id": "FC0150", + "constant": "cInFC0150", + "hwAddress": "%E015.0", + "comment": "MSS ausgelöst FC0150 (CV-M4302_B)", + "role": "motorProtection", + "unit": "M4302_B", + "cabinet": null, + "pos": [ + 331328.7, + 453508.3 + ] + }, + { + "id": "FC0151", + "constant": "cInFC0151", + "hwAddress": "%E015.1", + "comment": "MSS ausgelöst FC0151 (CV-M4402_B)", + "role": "motorProtection", + "unit": "M4402_B", + "cabinet": null, + "pos": [ + 331346.9, + 453230.1 + ] + }, + { + "id": "FC0152", + "constant": "cInFC0152", + "hwAddress": "%E015.2", + "comment": "MSS ausgelöst FC0152 (CV-M4103_B)", + "role": "motorProtection", + "unit": "M4103_B", + "cabinet": null, + "pos": [ + 331346.9, + 452960.1 + ] + }, + { + "id": "FC0153", + "constant": "cInFC0153", + "hwAddress": "%E015.3", + "comment": "MSS ausgelöst FC0153 (CV-M4203_B)", + "role": "motorProtection", + "unit": "M4203_B", + "cabinet": null, + "pos": [ + 331346.9, + 452690.1 + ] + }, + { + "id": "FC0154", + "constant": "cInFC0154", + "hwAddress": "%E015.4", + "comment": "MSS ausgelöst FC0154 (CV-M4302_A)", + "role": "motorProtection", + "unit": "M4302_A", + "cabinet": null, + "pos": [ + 331346.9, + 452420.1 + ] + }, + { + "id": "FC0155", + "constant": "cInFC0155", + "hwAddress": "%E015.5", + "comment": "MSS ausgelöst FC0155 (CV-M4402_A)", + "role": "motorProtection", + "unit": "M4402_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG0280", + "constant": "cInBG0280", + "hwAddress": "%E028.0", + "comment": "in Separator LS 1", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0110", + "pos": [ + 370801.0, + 187134.4 + ] + }, + { + "id": "BG0282", + "constant": "cInBG0282", + "hwAddress": "%E028.2", + "comment": "in Separator Beladeposition 1, LS 1", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0110", + "pos": [ + 370806.4, + 188671.0 + ] + }, + { + "id": "BG0283", + "constant": "cInBG0283", + "hwAddress": "%E028.3", + "comment": "in Separator Beladeposition 2, LS 1", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0110", + "pos": [ + 373091.5, + 187302.4 + ] + }, + { + "id": "BG0284", + "constant": "cInBG0284", + "hwAddress": "%E028.4", + "comment": "Rad dreht (KR- LS 1)", + "role": "sensorWheel", + "unit": null, + "cabinet": "UC0110", + "pos": [ + 373091.7, + 186925.6 + ] + }, + { + "id": "BG0285", + "constant": "cInBG0285", + "hwAddress": "%E028.5", + "comment": "Stausensor Staubereich nach Beladung voll", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0110", + "pos": [ + 373091.7, + 186590.2 + ] + }, + { + "id": "BG0286", + "constant": "cInBG0286", + "hwAddress": "%E028.6", + "comment": "Stausensor Staubereich voll Einfahrt Kreisel", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0111", + "pos": [ + 370704.6, + 183190.3 + ] + }, + { + "id": "BG0287", + "constant": "cInBG0287", + "hwAddress": "%E028.7", + "comment": "LS 1 Sensor 2m ausgefahren", + "role": null, + "unit": null, + "cabinet": "UC0110", + "pos": [ + 370715.7, + 179601.7 + ] + }, + { + "id": "SF0305", + "constant": "cInSF0305", + "hwAddress": "%E030.5", + "comment": "Freigabe MT UZ0110-1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 372721.9, + 191196.1 + ] + }, + { + "id": "SF0306", + "constant": "cInSF0306", + "hwAddress": "%E030.6", + "comment": "Beladeposition 2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 372721.9, + 190926.1 + ] + }, + { + "id": "FC0320", + "constant": "cInFC0320", + "hwAddress": "%E032.0", + "comment": "MSS ausgelöst FC0320 Kreisel", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 373091.7, + 183202.0 + ] + }, + { + "id": "FC0321", + "constant": "cInFC0321", + "hwAddress": "%E032.1", + "comment": "MSS ausgelöst FC0321 Stützfuß LS1", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 370318.0, + 185480.0 + ] + }, + { + "id": "SF0322", + "constant": "cInSF0322", + "hwAddress": "%E032.2", + "comment": "Stützfuß hat Endlage unten erreicht", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 373092.7, + 186148.0 + ] + }, + { + "id": "SF0323", + "constant": "cInSF0323", + "hwAddress": "%E032.3", + "comment": "Stützfuß hat Endlage oben erreicht", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 373092.7, + 185878.0 + ] + }, + { + "id": "DI0327", + "constant": "cInDI0327", + "hwAddress": "%E032.7", + "comment": "SEW MOVIMOT OK LS1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 371060.2, + 184946.7 + ] + }, + { + "id": "SF0330", + "constant": "cInSF0330", + "hwAddress": "%E033.0", + "comment": "Ladeschleife einfahren UZ0110-2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 369792.1, + 190979.9 + ] + }, + { + "id": "SF0331", + "constant": "cInSF0331", + "hwAddress": "%E033.1", + "comment": "Ladeschleife ausfahren UZ0110-2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 369792.1, + 190709.9 + ] + }, + { + "id": "SF0332", + "constant": "cInSF0332", + "hwAddress": "%E033.2", + "comment": "Freigabe MT ausfahren UZ0110-2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 369792.1, + 190439.9 + ] + }, + { + "id": "SF0333", + "constant": "cInSF0333", + "hwAddress": "%E033.3", + "comment": "Stützfuß ab LS1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 370170.0, + 186556.6 + ] + }, + { + "id": "SF0334", + "constant": "cInSF0334", + "hwAddress": "%E033.4", + "comment": "Stützfuß auf LS1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 370170.0, + 186286.6 + ] + }, + { + "id": "BG0340", + "constant": "cInBG0340", + "hwAddress": "%E034.0", + "comment": "in Separator LS2", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0111", + "pos": [ + 376774.1, + 187154.7 + ] + }, + { + "id": "BG0342", + "constant": "cInBG0342", + "hwAddress": "%E034.2", + "comment": "in Separator Beladeposition 1, LS 2", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0111", + "pos": [ + 376776.2, + 188724.9 + ] + }, + { + "id": "BG0343", + "constant": "cInBG0343", + "hwAddress": "%E034.3", + "comment": "in Separator", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0111", + "pos": [ + 379125.6, + 187301.8 + ] + }, + { + "id": "BG0344", + "constant": "cInBG0344", + "hwAddress": "%E034.4", + "comment": "Rad dreht (KR- LS 2)", + "role": "sensorWheel", + "unit": null, + "cabinet": "UC0111", + "pos": [ + 379125.8, + 186925.0 + ] + }, + { + "id": "BG0345", + "constant": "cInBG0345", + "hwAddress": "%E034.5", + "comment": "Stausensor Staubereich nach Beladung voll", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0111", + "pos": [ + 379125.8, + 186589.7 + ] + }, + { + "id": "BG0346", + "constant": "cInBG0346", + "hwAddress": "%E034.6", + "comment": "Stausensor 2 (KR-M1102)", + "role": "sensorJam", + "unit": "M1102", + "cabinet": "UC0111", + "pos": [ + 376704.6, + 183190.3 + ] + }, + { + "id": "BG0347", + "constant": "cInBG0347", + "hwAddress": "%E034.7", + "comment": "LS 2 Sensor 2m ausgefahren", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0111", + "pos": [ + 376715.7, + 179601.7 + ] + }, + { + "id": "SF0365", + "constant": "cInSF0365", + "hwAddress": "%E036.5", + "comment": "Freigabe MT UZ0111-1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 378698.6, + 191196.7 + ] + }, + { + "id": "SF0366", + "constant": "cInSF0366", + "hwAddress": "%E036.6", + "comment": "Beladeposition 2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 378698.6, + 190926.7 + ] + }, + { + "id": "FC0380", + "constant": "cInFC0380", + "hwAddress": "%E038.0", + "comment": "MSS ausgelöst FC0380 Kreisel", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 379125.8, + 183202.0 + ] + }, + { + "id": "FC0381", + "constant": "cInFC0381", + "hwAddress": "%E038.1", + "comment": "MSS ausgelöst FC0381 Stützfuß LS2", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 376298.4, + 185541.6 + ] + }, + { + "id": "SF0382", + "constant": "cInSF0382", + "hwAddress": "%E038.2", + "comment": "Stützfuß hat Endlage unten erreicht", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 379126.8, + 186147.4 + ] + }, + { + "id": "SF0383", + "constant": "cInSF0383", + "hwAddress": "%E038.3", + "comment": "Stützfuß hat Endlage oben erreicht", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 379126.8, + 185877.4 + ] + }, + { + "id": "DI0387", + "constant": "cInDI0387", + "hwAddress": "%E038.7", + "comment": "SEW MOVIMOT OK LS2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 377040.6, + 185008.4 + ] + }, + { + "id": "SF0390", + "constant": "cInSF0390", + "hwAddress": "%E039.0", + "comment": "Ladeschleife einfahren UZ0111-2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 375754.2, + 190980.5 + ] + }, + { + "id": "SF0391", + "constant": "cInSF0391", + "hwAddress": "%E039.1", + "comment": "Ladeschleife ausfahren UZ0111-2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 375754.2, + 190710.5 + ] + }, + { + "id": "SF0392", + "constant": "cInSF0392", + "hwAddress": "%E039.2", + "comment": "Freigabe MT UZ0111-2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 375754.2, + 190440.5 + ] + }, + { + "id": "SF0393", + "constant": "cInSF0393", + "hwAddress": "%E039.3", + "comment": "Stützfuß ab LS2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 376203.0, + 186556.6 + ] + }, + { + "id": "SF0394", + "constant": "cInSF0394", + "hwAddress": "%E039.4", + "comment": "Stützfuß auf LS2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 376203.0, + 186286.6 + ] + }, + { + "id": "SF0400", + "constant": "cInSF0400", + "hwAddress": "%E040.0", + "comment": "Not Halt Kanal 1 UH01", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 142885.2 + ] + }, + { + "id": "SF0401", + "constant": "cInSF0401", + "hwAddress": "%E040.1", + "comment": "Not Halt Kanal 1 UZ0101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 335107.8, + 169667.1 + ] + }, + { + "id": "SF0402", + "constant": "cInSF0402", + "hwAddress": "%E040.2", + "comment": "Not Halt Kanal 1 UZ0102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 324061.5, + 150800.9 + ] + }, + { + "id": "SF0403", + "constant": "cInSF0403", + "hwAddress": "%E040.3", + "comment": "Not Halt Kanal 1 LS 1 UZ0103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 333199.4, + 149118.3 + ] + }, + { + "id": "SF0404", + "constant": "cInSF0404", + "hwAddress": "%E040.4", + "comment": "Not Halt Kanal 2 UH01", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 142615.2 + ] + }, + { + "id": "SF0405", + "constant": "cInSF0405", + "hwAddress": "%E040.5", + "comment": "Not Halt Kanal 2 UZ0101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 335107.8, + 169397.1 + ] + }, + { + "id": "SF0406", + "constant": "cInSF0406", + "hwAddress": "%E040.6", + "comment": "Not Halt Kanal 2 UZ0102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 324061.5, + 150530.9 + ] + }, + { + "id": "SF0407", + "constant": "cInSF0407", + "hwAddress": "%E040.7", + "comment": "Not Halt Kanal 2 LS 1 UZ0103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 333199.4, + 148848.3 + ] + }, + { + "id": "SF0470", + "constant": "cInSF0470", + "hwAddress": "%E047.0", + "comment": "Not Halt Kanal 1 LS 2 UZ0104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 336301.7, + 149139.4 + ] + }, + { + "id": "SF0471", + "constant": "cInSF0471", + "hwAddress": "%E047.1", + "comment": "Not Halt Schnittstelle CH1 (Reserve)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 135629.7 + ] + }, + { + "id": "SF0474", + "constant": "cInSF0474", + "hwAddress": "%E047.4", + "comment": "Not Halt Kanal 2 LS 2 UZ0104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 336301.7, + 148869.4 + ] + }, + { + "id": "SF0475", + "constant": "cInSF0475", + "hwAddress": "%E047.5", + "comment": "Not Halt Schnittstelle CH2 (Reserve)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 327917.1, + 135359.7 + ] + }, + { + "id": "SF0710", + "constant": "cInSF0710", + "hwAddress": "%E071.0", + "comment": "Not Halt Kanal 1 UC011", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 329344.4, + 458152.9 + ] + }, + { + "id": "SF0714", + "constant": "cInSF0714", + "hwAddress": "%E071.4", + "comment": "Not Halt Kanal 2 UC011", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 329344.4, + 457882.9 + ] + }, + { + "id": "SF0781", + "constant": "cInSF0781", + "hwAddress": "%E078.1", + "comment": "Not Halt Schnittstelle CH1 (from UH06)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 329462.4, + 454535.6 + ] + }, + { + "id": "SF0785", + "constant": "cInSF0785", + "hwAddress": "%E078.5", + "comment": "Not Halt Schnittstelle CH2 (from UH0X)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 329462.4, + 454265.6 + ] + }, + { + "id": "SF1640", + "constant": "cInSF1640", + "hwAddress": "%E164.0", + "comment": "Not Halt Kanal 1 UZ0110-1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 372721.9, + 190656.1 + ] + }, + { + "id": "SF1644", + "constant": "cInSF1644", + "hwAddress": "%E164.4", + "comment": "Not Halt Kanal 2 UZ0110-1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 372721.9, + 190386.1 + ] + }, + { + "id": "SF1950", + "constant": "cInSF1950", + "hwAddress": "%E195.0", + "comment": "Not Halt Kanal 1 UZ0111-1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 378698.6, + 190656.7 + ] + }, + { + "id": "SF1954", + "constant": "cInSF1954", + "hwAddress": "%E195.4", + "comment": "Not Halt Kanal 2 UZ0111-1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 378698.6, + 190386.7 + ] + }, + { + "id": "BG3000", + "constant": "cInBG3000", + "hwAddress": "%E300.0", + "comment": "Sensor Förderer voll (ILS-CV M4104)", + "role": "sensorConvFull", + "unit": "M4104", + "cabinet": "UC1101", + "pos": [ + 337728.9, + 464143.0 + ] + }, + { + "id": "BG3001", + "constant": "cInBG3001", + "hwAddress": "%E300.1", + "comment": "Stausensor 1 (ILS-CV M4104)", + "role": "sensorJam", + "unit": "M4104", + "cabinet": "UC1101", + "pos": [ + 337726.1, + 463263.8 + ] + }, + { + "id": "BG3002", + "constant": "cInBG3002", + "hwAddress": "%E300.2", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4103_A)", + "role": "sensorFinger", + "unit": "M4103_A", + "cabinet": "UC1101", + "pos": [ + 337828.8, + 458991.6 + ] + }, + { + "id": "BG3003", + "constant": "cInBG3003", + "hwAddress": "%E300.3", + "comment": "in Separator 1 (ILS-CV M4103_A)", + "role": "sensorInSep", + "unit": "M4103_A", + "cabinet": "UC1101", + "pos": [ + 337826.1, + 458045.6 + ] + }, + { + "id": "BG3004", + "constant": "cInBG3004", + "hwAddress": "%E300.4", + "comment": "MT in Position (ILS-CV M4103_A)", + "role": "sensorCarrInPos", + "unit": "M4103_A", + "cabinet": "UC1101", + "pos": [ + 337826.1, + 458652.7 + ] + }, + { + "id": "BG3005", + "constant": "cInBG3005", + "hwAddress": "%E300.5", + "comment": "Stausensor (ILS-CV M4103_A)", + "role": "sensorJam", + "unit": "M4103_A", + "cabinet": "UC1101", + "pos": [ + 316721.1, + 449302.2 + ] + }, + { + "id": "BG3006", + "constant": "cInBG3006", + "hwAddress": "%E300.6", + "comment": "Sensor Förderer voll (ILS-CV M4103_A)", + "role": "sensorConvFull", + "unit": "M4103_A", + "cabinet": "UC1101", + "pos": [ + 318214.0, + 449306.3 + ] + }, + { + "id": "BG3007", + "constant": "cInBG3007", + "hwAddress": "%E300.7", + "comment": "Rad dreht (ILS-KR-M4204)", + "role": "sensorWheel", + "unit": "M4204", + "cabinet": null, + "pos": null + }, + { + "id": "BG3010", + "constant": "cInBG3010", + "hwAddress": "%E301.0", + "comment": "in Separator 1 (ILS-KR-M4204)", + "role": "sensorInSep", + "unit": "M4204", + "cabinet": "UC1101", + "pos": [ + 337168.3, + 451775.4 + ] + }, + { + "id": "BG3011", + "constant": "cInBG3011", + "hwAddress": "%E301.1", + "comment": "MT in Position (ILS-CV M4501))", + "role": "sensorCarrInPos", + "unit": "M4501", + "cabinet": "UC1101", + "pos": [ + 339850.9, + 452836.9 + ] + }, + { + "id": "BG3012", + "constant": "cInBG3012", + "hwAddress": "%E301.2", + "comment": "Stausensor 2 (ILS-KR-M4204)", + "role": "sensorJam", + "unit": "M4204", + "cabinet": "UC1101", + "pos": [ + 339281.0, + 449880.4 + ] + }, + { + "id": "BG3013", + "constant": "cInBG3013", + "hwAddress": "%E301.3", + "comment": "in Separator 2 (ILS-KR-M4204)", + "role": "sensorInSep", + "unit": "M4204", + "cabinet": "UC1101", + "pos": [ + 339798.4, + 449335.3 + ] + }, + { + "id": "BG3014", + "constant": "cInBG3014", + "hwAddress": "%E301.4", + "comment": "Stausensor nach Ausfahrt KR-M4204 ( ILS-CV M4203)", + "role": "sensorJam", + "unit": "M4204", + "cabinet": "UC1101", + "pos": [ + 340480.9, + 449875.3 + ] + }, + { + "id": "BG3015", + "constant": "cInBG3015", + "hwAddress": "%E301.5", + "comment": "Stausensor 1 (ILS-KR-M4204)", + "role": "sensorJam", + "unit": "M4204", + "cabinet": "UC1101", + "pos": [ + 338892.5, + 450624.7 + ] + }, + { + "id": "BG3016", + "constant": "cInBG3016", + "hwAddress": "%E301.6", + "comment": "Stausensor (ILS-KR-M4204)", + "role": "sensorJam", + "unit": "M4204", + "cabinet": "UC1101", + "pos": [ + 339850.0, + 451372.0 + ] + }, + { + "id": "BG3017", + "constant": "cInBG3017", + "hwAddress": "%E301.7", + "comment": "Staumelder, Einfahrt (ILS-CV M4501)", + "role": "sensorJam", + "unit": "M4501", + "cabinet": "UC1101", + "pos": [ + 339850.0, + 451672.1 + ] + }, + { + "id": "BG3020", + "constant": "cInBG3020", + "hwAddress": "%E302.0", + "comment": "in Separator 1 (ILS-CV M4501)", + "role": "sensorInSep", + "unit": "M4501", + "cabinet": "UC1101", + "pos": [ + 339850.0, + 451981.6 + ] + }, + { + "id": "BG3021", + "constant": "cInBG3021", + "hwAddress": "%E302.1", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4501)", + "role": "sensorFinger", + "unit": "M4501", + "cabinet": "UC1101", + "pos": [ + 339852.7, + 452547.1 + ] + }, + { + "id": "BG3022", + "constant": "cInBG3022", + "hwAddress": "%E302.2", + "comment": "Stausensor 1 (ILS-CV M4501)", + "role": "sensorJam", + "unit": "M4501", + "cabinet": "UC1101", + "pos": [ + 339962.8, + 457975.1 + ] + }, + { + "id": "BG3023", + "constant": "cInBG3023", + "hwAddress": "%E302.3", + "comment": "Sensor (ILS-CV M4501)", + "role": "sensorConvFull", + "unit": "M4501", + "cabinet": "UC1101", + "pos": [ + 339956.2, + 457156.6 + ] + }, + { + "id": "BG3024", + "constant": "cInBG3024", + "hwAddress": "%E302.4", + "comment": "in Separator 1 (ILS-CV M4203)", + "role": "sensorInSep", + "unit": "M4203", + "cabinet": "UC1101", + "pos": [ + 340763.2, + 451843.0 + ] + }, + { + "id": "BG3025", + "constant": "cInBG3025", + "hwAddress": "%E302.5", + "comment": "in Separator (ILS-CV M4104)", + "role": "sensorInSep", + "unit": "M4104", + "cabinet": "UC1101", + "pos": [ + 345082.0, + 154417.2 + ] + }, + { + "id": "BG3026", + "constant": "cInBG3026", + "hwAddress": "%E302.6", + "comment": "MT in Position (ILS-CV M4104)", + "role": "sensorCarrInPos", + "unit": "M4104", + "cabinet": "UC1101", + "pos": [ + 345082.5, + 155743.7 + ] + }, + { + "id": "BG3027", + "constant": "cInBG3027", + "hwAddress": "%E302.7", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4104)", + "role": "sensorFinger", + "unit": "M4104", + "cabinet": "UC1101", + "pos": [ + 345084.9, + 155398.4 + ] + }, + { + "id": "BG3060", + "constant": "cInBG3060", + "hwAddress": "%E306.0", + "comment": "in Separator 1 (ILS-CV M4503)", + "role": "sensorInSep", + "unit": "M4503", + "cabinet": "UC1102", + "pos": [ + 360615.0, + 453809.0 + ] + }, + { + "id": "BG3061", + "constant": "cInBG3061", + "hwAddress": "%E306.1", + "comment": "Stausensor (ILS-CV M4503)", + "role": "sensorJam", + "unit": "M4503", + "cabinet": "UC1102", + "pos": [ + 364660.8, + 453815.0 + ] + }, + { + "id": "BG3062", + "constant": "cInBG3062", + "hwAddress": "%E306.2", + "comment": "Sensor (ILS-CV M4503)", + "role": "sensorConvFull", + "unit": "M4503", + "cabinet": "UC1102", + "pos": [ + 365411.3, + 453819.1 + ] + }, + { + "id": "BG3063", + "constant": "cInBG3063", + "hwAddress": "%E306.3", + "comment": "in Separator 1 (ILS-CV M4502)", + "role": "sensorInSep", + "unit": "M4502", + "cabinet": "UC1102", + "pos": [ + 359662.3, + 453809.0 + ] + }, + { + "id": "BG3064", + "constant": "cInBG3064", + "hwAddress": "%E306.4", + "comment": "MT in Position (ILS-CV M4502))", + "role": "sensorCarrInPos", + "unit": "M4502", + "cabinet": "UC1102", + "pos": [ + 358178.1, + 453809.6 + ] + }, + { + "id": "BG3065", + "constant": "cInBG3065", + "hwAddress": "%E306.5", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4502)", + "role": "sensorFinger", + "unit": "M4502", + "cabinet": "UC1102", + "pos": [ + 358922.5, + 453812.5 + ] + }, + { + "id": "BG3066", + "constant": "cInBG3066", + "hwAddress": "%E306.6", + "comment": "Sensor Förderer voll (ILS-CV M4502)", + "role": "sensorConvFull", + "unit": "M4502", + "cabinet": "UC1102", + "pos": [ + 357181.0, + 453611.9 + ] + }, + { + "id": "BG3067", + "constant": "cInBG3067", + "hwAddress": "%E306.7", + "comment": "Stausensor 1 (ILS-CV M4502)", + "role": "sensorJam", + "unit": "M4502", + "cabinet": "UC1102", + "pos": [ + 356438.5, + 453607.5 + ] + }, + { + "id": "BG3070", + "constant": "cInBG3070", + "hwAddress": "%E307.0", + "comment": "Sensor (ILS-CV M4403)", + "role": "sensorConvFull", + "unit": "M4403", + "cabinet": "UC1102", + "pos": [ + 356383.1, + 451994.6 + ] + }, + { + "id": "BG3071", + "constant": "cInBG3071", + "hwAddress": "%E307.1", + "comment": "Stausensor 1 (ILS-CV M4403)", + "role": "sensorJam", + "unit": "M4403", + "cabinet": "UC1102", + "pos": [ + 356897.2, + 451720.4 + ] + }, + { + "id": "BG3073", + "constant": "cInBG3073", + "hwAddress": "%E307.3", + "comment": "in Separator 2 (ILS-CV M4403)", + "role": "sensorInSep", + "unit": "M4403", + "cabinet": "UC1102", + "pos": [ + 337468.2, + 446394.9 + ] + }, + { + "id": "BG3074", + "constant": "cInBG3074", + "hwAddress": "%E307.4", + "comment": "MT in Position (ILS-CV M4403)", + "role": "sensorCarrInPos", + "unit": "M4403", + "cabinet": "UC1102", + "pos": [ + 338953.2, + 446664.9 + ] + }, + { + "id": "BG3075", + "constant": "cInBG3075", + "hwAddress": "%E307.5", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4403)", + "role": "sensorFinger", + "unit": "M4403", + "cabinet": "UC1102", + "pos": [ + 338213.4, + 446668.3 + ] + }, + { + "id": "BG3080", + "constant": "cInBG3080", + "hwAddress": "%E308.0", + "comment": "in Separator 2 (ILS-CV M4503)", + "role": "sensorInSep", + "unit": "M4503", + "cabinet": "UC1102", + "pos": [ + 380643.1, + 751272.8 + ] + }, + { + "id": "BG3081", + "constant": "cInBG3081", + "hwAddress": "%E308.1", + "comment": "Abfrage Mitnehmerfinger in Position in Separator 2 (ILS-CV M4503)", + "role": "sensorFinger", + "unit": "M4503", + "cabinet": "UC1102", + "pos": [ + 380646.1, + 751861.1 + ] + }, + { + "id": "BG3082", + "constant": "cInBG3082", + "hwAddress": "%E308.2", + "comment": "MT in Position (ILS-CV M4503)", + "role": "sensorCarrInPos", + "unit": "M4503", + "cabinet": "UC1102", + "pos": [ + 380646.1, + 752131.1 + ] + }, + { + "id": "BG3120", + "constant": "cInBG3120", + "hwAddress": "%E312.0", + "comment": "in Separator (ILS-CV M4203_A)", + "role": "sensorInSep", + "unit": "M4203_A", + "cabinet": "UC1103", + "pos": [ + 337068.7, + 449398.6 + ] + }, + { + "id": "BG3121", + "constant": "cInBG3121", + "hwAddress": "%E312.1", + "comment": "MT in Position (ILS-CV M4203_A)", + "role": "sensorCarrInPos", + "unit": "M4203_A", + "cabinet": "UC1103", + "pos": [ + 337068.7, + 448870.6 + ] + }, + { + "id": "BG3122", + "constant": "cInBG3122", + "hwAddress": "%E312.2", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4302_A)", + "role": "sensorFinger", + "unit": "M4302_A", + "cabinet": "UC1103", + "pos": [ + 337071.4, + 449132.1 + ] + }, + { + "id": "BG3123", + "constant": "cInBG3123", + "hwAddress": "%E312.3", + "comment": "Sensor (ILS-CV M4203_A)", + "role": "sensorConvFull", + "unit": "M4203_A", + "cabinet": "UC1103", + "pos": [ + 318453.9, + 446790.8 + ] + }, + { + "id": "BG3124", + "constant": "cInBG3124", + "hwAddress": "%E312.4", + "comment": "Stausensor (ILS-CV M4203_A)", + "role": "sensorJam", + "unit": "M4203_A", + "cabinet": "UC1103", + "pos": [ + 317703.5, + 446786.6 + ] + }, + { + "id": "BG3125", + "constant": "cInBG3125", + "hwAddress": "%E312.5", + "comment": "in Separator (ILS-CV M4302)", + "role": "sensorInSep", + "unit": "M4302", + "cabinet": "UC1103", + "pos": [ + 338356.4, + 449090.6 + ] + }, + { + "id": "BG3126", + "constant": "cInBG3126", + "hwAddress": "%E312.6", + "comment": "Stausensor (ILS-CV M4302_B)", + "role": "sensorJam", + "unit": "M4302_B", + "cabinet": "UC1103", + "pos": [ + 326272.8, + 448899.6 + ] + }, + { + "id": "BG3127", + "constant": "cInBG3127", + "hwAddress": "%E312.7", + "comment": "Sensor Förderer voll (ILS-CV M4302_B)", + "role": "sensorConvFull", + "unit": "M4302_B", + "cabinet": "UC1103", + "pos": [ + 325538.3, + 448903.7 + ] + }, + { + "id": "BG3130", + "constant": "cInBG3130", + "hwAddress": "%E313.0", + "comment": "in Separator 2 (ILS-CV M4302_B)", + "role": "sensorInSep", + "unit": "M4302_B", + "cabinet": "UC1103", + "pos": [ + 320086.4, + 449305.0 + ] + }, + { + "id": "BG3131", + "constant": "cInBG3131", + "hwAddress": "%E313.1", + "comment": "MT in Position (ILS-CV M4302_B)", + "role": "sensorCarrInPos", + "unit": "M4302_B", + "cabinet": "UC1103", + "pos": [ + 322328.0, + 449302.4 + ] + }, + { + "id": "BG3132", + "constant": "cInBG3132", + "hwAddress": "%E313.2", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4302_B)", + "role": "sensorFinger", + "unit": "M4302_B", + "cabinet": "UC1103", + "pos": [ + 320845.7, + 449305.9 + ] + }, + { + "id": "BG3133", + "constant": "cInBG3133", + "hwAddress": "%E313.3", + "comment": "Sensor Förderer voll (ILS-CV M4402_B)", + "role": "sensorConvFull", + "unit": "M4402_B", + "cabinet": "UC1103", + "pos": [ + 324835.9, + 446793.7 + ] + }, + { + "id": "BG3134", + "constant": "cInBG3134", + "hwAddress": "%E313.4", + "comment": "Stausensor (ILS-CV M4402_B)", + "role": "sensorJam", + "unit": "M4402_B", + "cabinet": "UC1103", + "pos": [ + 327054.8, + 446789.5 + ] + }, + { + "id": "BG3135", + "constant": "cInBG3135", + "hwAddress": "%E313.5", + "comment": "in Separator 2 (ILS-CV M4402_B)", + "role": "sensorInSep", + "unit": "M4402_B", + "cabinet": "UC1103", + "pos": [ + 320641.6, + 446789.7 + ] + }, + { + "id": "BG3136", + "constant": "cInBG3136", + "hwAddress": "%E313.6", + "comment": "MT in Position (ILS-CV M4402_B)", + "role": "sensorCarrInPos", + "unit": "M4402_B", + "cabinet": "UC1103", + "pos": [ + 322126.6, + 446789.5 + ] + }, + { + "id": "BG3137", + "constant": "cInBG3137", + "hwAddress": "%E313.7", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4402_B)", + "role": "sensorFinger", + "unit": "M4402_B", + "cabinet": "UC1103", + "pos": [ + 321386.8, + 446793.0 + ] + }, + { + "id": "BG3140", + "constant": "cInBG3140", + "hwAddress": "%E314.0", + "comment": "Staumelder, Einfahrt (ILS-CV M4103_A)", + "role": "sensorJam", + "unit": "M4103_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3142", + "constant": "cInBG3142", + "hwAddress": "%E314.2", + "comment": "Sensor Förderer voll (ILS-CV M4103_B)", + "role": "sensorConvFull", + "unit": "M4103_B", + "cabinet": null, + "pos": null + }, + { + "id": "BG3143", + "constant": "cInBG3143", + "hwAddress": "%E314.3", + "comment": "Stausensor (ILS-CV M4103_B)", + "role": "sensorJam", + "unit": "M4103_B", + "cabinet": null, + "pos": null + }, + { + "id": "BG3144", + "constant": "cInBG3144", + "hwAddress": "%E314.4", + "comment": "Staumelder, Einfahrt (ILS-CV M4203_A)", + "role": "sensorJam", + "unit": "M4203_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3146", + "constant": "cInBG3146", + "hwAddress": "%E314.6", + "comment": "Sensor Förderer voll (ILS-CV M4203_B)", + "role": "sensorConvFull", + "unit": "M4203_B", + "cabinet": null, + "pos": null + }, + { + "id": "BG3147", + "constant": "cInBG3147", + "hwAddress": "%E314.7", + "comment": "Stausensor (ILS-CV M4203_B)", + "role": "sensorJam", + "unit": "M4203_B", + "cabinet": null, + "pos": null + }, + { + "id": "BG3150", + "constant": "cInBG3150", + "hwAddress": "%E315.0", + "comment": "Staumelder, Einfahrt (ILS-CV M4302_A)", + "role": "sensorJam", + "unit": "M4302_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3152", + "constant": "cInBG3152", + "hwAddress": "%E315.2", + "comment": "Sensor Förderer voll (ILS-CV M4302_A)", + "role": "sensorConvFull", + "unit": "M4302_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3153", + "constant": "cInBG3153", + "hwAddress": "%E315.3", + "comment": "Stausensor (ILS-CV M4302_A)", + "role": "sensorJam", + "unit": "M4302_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3154", + "constant": "cInBG3154", + "hwAddress": "%E315.4", + "comment": "Staumelder, Einfahrt (ILS-CV M4402_A)", + "role": "sensorJam", + "unit": "M4402_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3156", + "constant": "cInBG3156", + "hwAddress": "%E315.6", + "comment": "Sensor Förderer voll (ILS-CV M4402_A)", + "role": "sensorConvFull", + "unit": "M4402_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3157", + "constant": "cInBG3157", + "hwAddress": "%E315.7", + "comment": "Stausensor (ILS-CV M4402_A)", + "role": "sensorJam", + "unit": "M4402_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3240", + "constant": "cInBG3240", + "hwAddress": "%E324.0", + "comment": "Sensor Förderer voll (ILS-CV M0100)", + "role": "sensorConvFull", + "unit": "M0100", + "cabinet": "UC0101", + "pos": [ + 341970.0, + 163236.5 + ] + }, + { + "id": "BG3241", + "constant": "cInBG3241", + "hwAddress": "%E324.1", + "comment": "Stausensor (ILS-CV M0100)", + "role": "sensorJam", + "unit": "M0100", + "cabinet": "UC0101", + "pos": [ + 341970.0, + 164121.6 + ] + }, + { + "id": "BG3242", + "constant": "cInBG3242", + "hwAddress": "%E324.2", + "comment": "in Separator 1 (ILS-CV M0100)", + "role": "sensorInSep", + "unit": "M0100", + "cabinet": "UC0101", + "pos": [ + 341906.1, + 164861.9 + ] + }, + { + "id": "BG3243", + "constant": "cInBG3243", + "hwAddress": "%E324.3", + "comment": "Stausensor 1 (KR-K0111)", + "role": "sensorJam", + "unit": "K0111", + "cabinet": "UC0101", + "pos": [ + 340392.2, + 165626.1 + ] + }, + { + "id": "BG3245", + "constant": "cInBG3245", + "hwAddress": "%E324.5", + "comment": "Stausensor 2 (KR-K0111)", + "role": "sensorJam", + "unit": "K0111", + "cabinet": "UC0101", + "pos": [ + 334191.9, + 166227.5 + ] + }, + { + "id": "BG3246", + "constant": "cInBG3246", + "hwAddress": "%E324.6", + "comment": "in Separator, Einfahrt MT-Buffer LS2 (KR-M0101)", + "role": "sensorInSep", + "unit": "M0101", + "cabinet": "UC0101", + "pos": [ + 337327.1, + 167031.0 + ] + }, + { + "id": "BG3250", + "constant": "cInBG3250", + "hwAddress": "%E325.0", + "comment": "Stausensor Str.01 (Block 1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 336751.3, + 164837.6 + ] + }, + { + "id": "BG3251", + "constant": "cInBG3251", + "hwAddress": "%E325.1", + "comment": "Stausensor Str.02 (Block 1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 336351.2, + 164519.5 + ] + }, + { + "id": "BG3252", + "constant": "cInBG3252", + "hwAddress": "%E325.2", + "comment": "Stausensor Str.03 (Block 1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 335537.1, + 164537.2 + ] + }, + { + "id": "BG3253", + "constant": "cInBG3253", + "hwAddress": "%E325.3", + "comment": "Stausensor Str.04 (Block 1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 335136.9, + 164829.4 + ] + }, + { + "id": "BG3254", + "constant": "cInBG3254", + "hwAddress": "%E325.4", + "comment": "Stausensor Str.05 (Block 1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 334736.9, + 164829.4 + ] + }, + { + "id": "BG3257", + "constant": "cInBG3257", + "hwAddress": "%E325.7", + "comment": "in Separator, Einfahrt MT-Buffer LS1 (KR-M0101)", + "role": "sensorInSep", + "unit": "M0101", + "cabinet": "UC0101", + "pos": [ + 331297.8, + 166996.9 + ] + }, + { + "id": "BG3260", + "constant": "cInBG3260", + "hwAddress": "%E326.0", + "comment": "Stausensor Str.01 (Block 1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 330751.2, + 164939.4 + ] + }, + { + "id": "BG3261", + "constant": "cInBG3261", + "hwAddress": "%E326.1", + "comment": "Stausensor Str.02 (Block 1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 330351.2, + 164939.4 + ] + }, + { + "id": "BG3262", + "constant": "cInBG3262", + "hwAddress": "%E326.2", + "comment": "Stausensor Str.03 (Block 1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 329951.2, + 164939.4 + ] + }, + { + "id": "BG3263", + "constant": "cInBG3263", + "hwAddress": "%E326.3", + "comment": "Stausensor Str.04 (Block 1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 329551.2, + 164939.4 + ] + }, + { + "id": "BG3264", + "constant": "cInBG3264", + "hwAddress": "%E326.4", + "comment": "Stausensor Str.05 (Block 1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 329151.2, + 164939.4 + ] + }, + { + "id": "BG3265", + "constant": "cInBG3265", + "hwAddress": "%E326.5", + "comment": "Sensor MT in Scanposition (ILS-CV M0106)", + "role": null, + "unit": "M0106", + "cabinet": null, + "pos": null + }, + { + "id": "BG3270", + "constant": "cInBG3270", + "hwAddress": "%E327.0", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV-M0103)", + "role": "sensorFinger", + "unit": "M0103", + "cabinet": "UC0101", + "pos": [ + 331107.8, + 163621.6 + ] + }, + { + "id": "BG3271", + "constant": "cInBG3271", + "hwAddress": "%E327.1", + "comment": "in Separator (ILS-CV M0103)", + "role": "sensorInSep", + "unit": "M0103", + "cabinet": "UC0101", + "pos": [ + 331115.1, + 163051.1 + ] + }, + { + "id": "BG3272", + "constant": "cInBG3272", + "hwAddress": "%E327.2", + "comment": "MT in Position (ILS-CV M0103)", + "role": "sensorCarrInPos", + "unit": "M0103", + "cabinet": "UC0101", + "pos": [ + 331115.4, + 164260.6 + ] + }, + { + "id": "BG3273", + "constant": "cInBG3273", + "hwAddress": "%E327.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M0106)", + "role": "sensorFinger", + "unit": "M0106", + "cabinet": "UC0101", + "pos": [ + 334111.3, + 164000.2 + ] + }, + { + "id": "BG3276", + "constant": "cInBG3276", + "hwAddress": "%E327.6", + "comment": "Stausensor (ILS-CV M0106)", + "role": "sensorJam", + "unit": "M0106", + "cabinet": "UC0101", + "pos": [ + 334141.4, + 161135.0 + ] + }, + { + "id": "BG3280", + "constant": "cInBG3280", + "hwAddress": "%E328.0", + "comment": "in Separator (ILS-BX1104)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 334141.1, + 159162.0 + ] + }, + { + "id": "BG3281", + "constant": "cInBG3281", + "hwAddress": "%E328.1", + "comment": "Stausensor(ILS-BX1104)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 334141.4, + 159713.2 + ] + }, + { + "id": "BG3282", + "constant": "cInBG3282", + "hwAddress": "%E328.2", + "comment": "MT in Position (ILS-CV M0107)", + "role": "sensorCarrInPos", + "unit": "M0107", + "cabinet": "UC0101", + "pos": [ + 337121.9, + 164267.5 + ] + }, + { + "id": "BG3283", + "constant": "cInBG3283", + "hwAddress": "%E328.3", + "comment": "in Separator (ILS-CV M0107)", + "role": "sensorInSep", + "unit": "M0107", + "cabinet": "UC0101", + "pos": [ + 337121.7, + 163008.9 + ] + }, + { + "id": "BG3284", + "constant": "cInBG3284", + "hwAddress": "%E328.4", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M0107)", + "role": "sensorFinger", + "unit": "M0107", + "cabinet": "UC0101", + "pos": [ + 337124.4, + 163578.9 + ] + }, + { + "id": "BG3285", + "constant": "cInBG3285", + "hwAddress": "%E328.5", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M0110)", + "role": "sensorFinger", + "unit": "M0110", + "cabinet": "UC0101", + "pos": [ + 340241.2, + 164375.0 + ] + }, + { + "id": "BG3290", + "constant": "cInBG3290", + "hwAddress": "%E329.0", + "comment": "in Separator 2 (ILS-CV M0100)", + "role": "sensorInSep", + "unit": "M0100", + "cabinet": "UC0101", + "pos": [ + 340300.1, + 463582.9 + ] + }, + { + "id": "BG3291", + "constant": "cInBG3291", + "hwAddress": "%E329.1", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M0100)", + "role": "sensorFinger", + "unit": "M0100", + "cabinet": "UC0101", + "pos": [ + 340302.8, + 463010.4 + ] + }, + { + "id": "BG3292", + "constant": "cInBG3292", + "hwAddress": "%E329.2", + "comment": "MT in Position (ILS-CV M0100)", + "role": "sensorCarrInPos", + "unit": "M0100", + "cabinet": "UC0101", + "pos": [ + 340300.1, + 463293.9 + ] + }, + { + "id": "BG3294", + "constant": "cInBG3294", + "hwAddress": "%E329.4", + "comment": "Stausensor (ILS-CV M0110)", + "role": "sensorJam", + "unit": "M0110", + "cabinet": "UC0101", + "pos": [ + 340352.5, + 160860.2 + ] + }, + { + "id": "BG3295", + "constant": "cInBG3295", + "hwAddress": "%E329.5", + "comment": "in Separator (ILS-CV)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 340343.6, + 159168.0 + ] + }, + { + "id": "BG3296", + "constant": "cInBG3296", + "hwAddress": "%E329.6", + "comment": "Stausensor (ILS-CV)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0101", + "pos": [ + 340352.5, + 159713.2 + ] + }, + { + "id": "BG3297", + "constant": "cInBG3297", + "hwAddress": "%E329.7", + "comment": "Sensor MT in Scanposition (ILS-CV M0110)", + "role": null, + "unit": "M0110", + "cabinet": null, + "pos": null + }, + { + "id": "BG3300", + "constant": "cInBG3300", + "hwAddress": "%E330.0", + "comment": "in Separator 1 (ILS-KR-M0102)", + "role": "sensorInSep", + "unit": "M0102", + "cabinet": null, + "pos": null + }, + { + "id": "BG3301", + "constant": "cInBG3301", + "hwAddress": "%E330.1", + "comment": "Teil auf MT (Sep 1MB3300)", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG3304", + "constant": "cInBG3304", + "hwAddress": "%E330.4", + "comment": "Stausensor 2 (ILS-KR-M0102)", + "role": "sensorJam", + "unit": "M0102", + "cabinet": "UC0102", + "pos": [ + 331977.1, + 152700.3 + ] + }, + { + "id": "BG3305", + "constant": "cInBG3305", + "hwAddress": "%E330.5", + "comment": "Stausensor (ILS-CV-M0103)", + "role": "sensorJam", + "unit": "M0103", + "cabinet": "UC0102", + "pos": [ + 332559.0, + 153731.6 + ] + }, + { + "id": "BG3306", + "constant": "cInBG3306", + "hwAddress": "%E330.6", + "comment": "in Separator 2 (ILS-KR-M0102)", + "role": "sensorInSep", + "unit": "M0102", + "cabinet": "UC0102", + "pos": [ + 333164.0, + 152427.8 + ] + }, + { + "id": "BG3310", + "constant": "cInBG3310", + "hwAddress": "%E331.0", + "comment": "in Separator 01 (Block 1.1.)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 331174.2, + 153905.5 + ] + }, + { + "id": "BG3311", + "constant": "cInBG3311", + "hwAddress": "%E331.1", + "comment": "in Separator 02 (Block 1.1.)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 330772.7, + 153905.5 + ] + }, + { + "id": "BG3312", + "constant": "cInBG3312", + "hwAddress": "%E331.2", + "comment": "in Separator 03 (Block 1.1.)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 330374.6, + 153905.5 + ] + }, + { + "id": "BG3313", + "constant": "cInBG3313", + "hwAddress": "%E331.3", + "comment": "in Separator 04 (Block 1.1.)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 329974.5, + 153905.5 + ] + }, + { + "id": "BG3314", + "constant": "cInBG3314", + "hwAddress": "%E331.4", + "comment": "in Separator 05 (Block 1.1.)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 329574.6, + 153905.5 + ] + }, + { + "id": "BG3315", + "constant": "cInBG3315", + "hwAddress": "%E331.5", + "comment": "in Separator (Block 1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 333680.0, + 153895.6 + ] + }, + { + "id": "BG3316", + "constant": "cInBG3316", + "hwAddress": "%E331.6", + "comment": "in Separator, (KR-M0102)", + "role": "sensorInSep", + "unit": "M0102", + "cabinet": null, + "pos": null + }, + { + "id": "BG3320", + "constant": "cInBG3320", + "hwAddress": "%E332.0", + "comment": "in Separator 01 (Block 1.2.)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 337174.2, + 153897.8 + ] + }, + { + "id": "BG3321", + "constant": "cInBG3321", + "hwAddress": "%E332.1", + "comment": "in Separator 02 (Block 1.2.)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 336774.2, + 153897.8 + ] + }, + { + "id": "BG3322", + "constant": "cInBG3322", + "hwAddress": "%E332.2", + "comment": "in Separator 03 (Block 1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 335578.9, + 153896.8 + ] + }, + { + "id": "BG3323", + "constant": "cInBG3323", + "hwAddress": "%E332.3", + "comment": "in Separator 04 (Block 1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 335178.9, + 153896.8 + ] + }, + { + "id": "BG3324", + "constant": "cInBG3324", + "hwAddress": "%E332.4", + "comment": "in Separator 05 (Block 1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 334778.9, + 153896.8 + ] + }, + { + "id": "BG3325", + "constant": "cInBG3325", + "hwAddress": "%E332.5", + "comment": "in Separator (Block 1.2.)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 340063.7, + 153903.2 + ] + }, + { + "id": "BG3330", + "constant": "cInBG3330", + "hwAddress": "%E333.0", + "comment": "Stausensor 3 (ILS-KR-M0102)", + "role": "sensorJam", + "unit": "M0102", + "cabinet": "UC0102", + "pos": [ + 337870.1, + 152700.3 + ] + }, + { + "id": "BG3331", + "constant": "cInBG3331", + "hwAddress": "%E333.1", + "comment": "Stausensor1", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 338558.8, + 153731.6 + ] + }, + { + "id": "BG3332", + "constant": "cInBG3332", + "hwAddress": "%E333.2", + "comment": "in Separator 3 (ILS-KR-M0102)", + "role": "sensorInSep", + "unit": "M0102", + "cabinet": "UC0102", + "pos": [ + 338655.7, + 152427.8 + ] + }, + { + "id": "BG3334", + "constant": "cInBG3334", + "hwAddress": "%E333.4", + "comment": "Stausensor 4 (ILS-KR-M0102)", + "role": "sensorJam", + "unit": "M0102", + "cabinet": "UC0102", + "pos": [ + 340330.7, + 153418.1 + ] + }, + { + "id": "BG3335", + "constant": "cInBG3335", + "hwAddress": "%E333.5", + "comment": "in Separator 4 (ILS-KR-M0102)", + "role": "sensorInSep", + "unit": "M0102", + "cabinet": "UC0102", + "pos": [ + 340147.1, + 152181.2 + ] + }, + { + "id": "BG3337", + "constant": "cInBG3337", + "hwAddress": "%E333.7", + "comment": "in Separator 5 (ILS-KR-M0102)", + "role": "sensorInSep", + "unit": "M0102", + "cabinet": "UC0102", + "pos": [ + 342176.9, + 153712.2 + ] + }, + { + "id": "BG3340", + "constant": "cInBG3340", + "hwAddress": "%E334.0", + "comment": "Stausensor (ILS-CV M4104)", + "role": "sensorJam", + "unit": "M4104", + "cabinet": "UC0102", + "pos": [ + 342925.4, + 153802.7 + ] + }, + { + "id": "BG3341", + "constant": "cInBG3341", + "hwAddress": "%E334.1", + "comment": "Stausensor 5 (ILS-KR-M0102)", + "role": "sensorJam", + "unit": "M0102", + "cabinet": "UC0102", + "pos": [ + 343066.4, + 151902.1 + ] + }, + { + "id": "BG3342", + "constant": "cInBG3342", + "hwAddress": "%E334.2", + "comment": "Rad dreht (ILS-KR-M0102)", + "role": "sensorWheel", + "unit": "M0102", + "cabinet": "UC0102", + "pos": [ + 343950.4, + 151913.5 + ] + }, + { + "id": "BG3343", + "constant": "cInBG3343", + "hwAddress": "%E334.3", + "comment": "LS Endlage ausgefahren", + "role": null, + "unit": null, + "cabinet": "UC0102", + "pos": [ + 370715.4, + 178268.7 + ] + }, + { + "id": "BG3344", + "constant": "cInBG3344", + "hwAddress": "%E334.4", + "comment": "LS Endlage eingefahren", + "role": null, + "unit": null, + "cabinet": "UC0102", + "pos": [ + 370715.4, + 178538.7 + ] + }, + { + "id": "BG3345", + "constant": "cInBG3345", + "hwAddress": "%E334.5", + "comment": "LS Endlage ausgefahren", + "role": null, + "unit": null, + "cabinet": "UC0102", + "pos": [ + 376715.4, + 178267.9 + ] + }, + { + "id": "BG3346", + "constant": "cInBG3346", + "hwAddress": "%E334.6", + "comment": "LS Endlage eingefahren", + "role": null, + "unit": null, + "cabinet": "UC0102", + "pos": [ + 376715.4, + 178537.9 + ] + }, + { + "id": "BG3347", + "constant": "cInBG3347", + "hwAddress": "%E334.7", + "comment": "Rad dreht (KR-M0101)", + "role": "sensorWheel", + "unit": "M0101", + "cabinet": null, + "pos": null + }, + { + "id": "BG3354", + "constant": "cInBG3354", + "hwAddress": "%E335.4", + "comment": "Längenabfrage Grenze kurz (ILS-CV)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 341041.2, + 152086.3 + ] + }, + { + "id": "BG3355", + "constant": "cInBG3355", + "hwAddress": "%E335.5", + "comment": "Längenabfrage Grenze lang (ILS-CV)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 341041.2, + 151816.3 + ] + }, + { + "id": "BG3356", + "constant": "cInBG3356", + "hwAddress": "%E335.6", + "comment": "Längenabfrage Grenze zu lang (ILS-CV)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0102", + "pos": [ + 341041.2, + 151546.3 + ] + }, + { + "id": "BG3357", + "constant": "cInBG3357", + "hwAddress": "%E335.7", + "comment": "Verlassensensor Längenmessung (ILS-CV)", + "role": null, + "unit": null, + "cabinet": "UC0102", + "pos": [ + 341041.2, + 151276.3 + ] + }, + { + "id": "BG4740", + "constant": "cInBG4740", + "hwAddress": "%E474.0", + "comment": "Neigungssensor Ladeschleife 1", + "role": null, + "unit": null, + "cabinet": "UC0110", + "pos": [ + 373091.7, + 185239.1 + ] + }, + { + "id": "BG4820", + "constant": "cInBG4820", + "hwAddress": "%E482.0", + "comment": "Bodenabstandssensor ( LS 1)", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG5060", + "constant": "cInBG5060", + "hwAddress": "%E506.0", + "comment": "Neigungssensor Ladeschleife 2", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG5140", + "constant": "cInBG5140", + "hwAddress": "%E514.0", + "comment": "Bodenabstandssensor ( LS 2)", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + } + ], + "units": [ + { + "unit": "K0111", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0101", + "pos": [ + 340392.2, + 165626.1 + ], + "io": { + "sensorJam": [ + "BG3243", + "BG3245" + ] + }, + "signalCount": 2 + }, + { + "unit": "M0100", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0101", + "pos": [ + 327898.7, + 132441.4 + ], + "io": { + "motorProtection": [ + "FC0057" + ], + "sensorConvFull": [ + "BG3240" + ], + "sensorJam": [ + "BG3241" + ], + "sensorInSep": [ + "BG3242", + "BG3290" + ], + "sensorFinger": [ + "BG3291" + ], + "sensorCarrInPos": [ + "BG3292" + ], + "motorOutput": [ + "MA0057" + ], + "stopperOutput": [ + "MB3290" + ] + }, + "signalCount": 9 + }, + { + "unit": "M0101", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [ + { + "id": "LS2", + "kind": "loadingStation" + }, + { + "id": "LS1", + "kind": "loadingStation" + } + ], + "cabinet": "UC0101", + "pos": [ + 327898.7, + 132171.4 + ], + "io": { + "motorProtection": [ + "FC0060" + ], + "sensorInSep": [ + "BG3246", + "BG3257" + ], + "sensorWheel": [ + "BG3347" + ], + "motorOutput": [ + "MA0060" + ], + "stopperOutput": [ + "MB3246", + "MB3257" + ] + }, + "signalCount": 7 + }, + { + "unit": "M0102", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep1Swi", + "areas": [], + "cabinet": "UC0102", + "pos": [ + 327898.7, + 131901.4 + ], + "io": { + "motorProtection": [ + "FC0061" + ], + "sensorInSep": [ + "BG3300", + "BG3306", + "BG3316", + "BG3332", + "BG3335", + "BG3337" + ], + "sensorJam": [ + "BG3304", + "BG3330", + "BG3334", + "BG3341" + ], + "sensorWheel": [ + "BG3342" + ], + "motorOutput": [ + "MA0061" + ], + "stopperOutput": [ + "MB3300", + "MB3306", + "MB3316", + "MB3332", + "MB3335", + "MB3337" + ], + "switchOutput": [ + "MB3304", + "MB3330", + "MB3340" + ] + }, + "signalCount": 22 + }, + { + "unit": "M0103", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0101", + "pos": [ + 327898.7, + 131631.4 + ], + "io": { + "motorProtection": [ + "FC0062" + ], + "sensorFinger": [ + "BG3270" + ], + "sensorInSep": [ + "BG3271" + ], + "sensorCarrInPos": [ + "BG3272" + ], + "sensorJam": [ + "BG3305" + ], + "stopperOutput": [ + "MB3271" + ] + }, + "signalCount": 6 + }, + { + "unit": "M0105", + "unitKind": "CV", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": null, + "pos": [ + 327898.7, + 131361.4 + ], + "io": { + "motorProtection": [ + "FC0063" + ] + }, + "signalCount": 1 + }, + { + "unit": "M0106", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0101", + "pos": [ + 330179.0, + 132367.5 + ], + "io": { + "motorProtection": [ + "FC0064" + ], + "sensorFinger": [ + "BG3273" + ], + "sensorJam": [ + "BG3276" + ], + "motorOutput": [ + "MA0064" + ] + }, + "signalCount": 5 + }, + { + "unit": "M0107", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0101", + "pos": [ + 330179.6, + 132097.5 + ], + "io": { + "motorProtection": [ + "FC0065" + ], + "sensorCarrInPos": [ + "BG3282" + ], + "sensorInSep": [ + "BG3283" + ], + "sensorFinger": [ + "BG3284" + ], + "motorOutput": [ + "MA0065" + ], + "stopperOutput": [ + "MB3283" + ] + }, + "signalCount": 6 + }, + { + "unit": "M0109", + "unitKind": "CV", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": null, + "pos": [ + 330198.7, + 131833.0 + ], + "io": { + "motorProtection": [ + "FC0066" + ] + }, + "signalCount": 1 + }, + { + "unit": "M0110", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0101", + "pos": [ + 330187.6, + 131557.5 + ], + "io": { + "motorProtection": [ + "FC0067" + ], + "sensorFinger": [ + "BG3285" + ], + "sensorJam": [ + "BG3294" + ], + "motorOutput": [ + "MA0067" + ] + }, + "signalCount": 5 + }, + { + "unit": "M1102", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0111", + "pos": [ + 376704.6, + 183190.3 + ], + "io": { + "sensorJam": [ + "BG0346" + ] + }, + "signalCount": 1 + }, + { + "unit": "M4103", + "unitKind": "CV", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": null, + "pos": [ + 329374.5, + 451880.1 + ], + "io": { + "motorProtection": [ + "FC0146" + ] + }, + "signalCount": 1 + }, + { + "unit": "M4103_A", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC011", + "pos": [ + 337828.8, + 458991.6 + ], + "io": { + "sensorFinger": [ + "BG3002" + ], + "sensorInSep": [ + "BG3003" + ], + "sensorCarrInPos": [ + "BG3004" + ], + "sensorJam": [ + "BG3005", + "BG3140" + ], + "sensorConvFull": [ + "BG3006" + ], + "motorOutput": [ + "MA0146" + ], + "stopperOutput": [ + "MB3003" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4103_B", + "unitKind": "CV", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": null, + "pos": [ + 331346.9, + 452960.1 + ], + "io": { + "motorProtection": [ + "FC0152" + ], + "sensorConvFull": [ + "BG3142" + ], + "sensorJam": [ + "BG3143" + ], + "motorOutput": [ + "MA0152" + ] + }, + "signalCount": 4 + }, + { + "unit": "M4104", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0102", + "pos": [ + 329374.5, + 452150.1 + ], + "io": { + "motorProtection": [ + "FC0145" + ], + "sensorConvFull": [ + "BG3000" + ], + "sensorJam": [ + "BG3001", + "BG3340" + ], + "sensorInSep": [ + "BG3025" + ], + "sensorCarrInPos": [ + "BG3026" + ], + "sensorFinger": [ + "BG3027" + ], + "motorOutput": [ + "MA0145" + ], + "stopperOutput": [ + "MB3025" + ] + }, + "signalCount": 9 + }, + { + "unit": "M4203", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC1101", + "pos": [ + 340763.2, + 451843.0 + ], + "io": { + "sensorInSep": [ + "BG3024" + ], + "stopperOutput": [ + "MB3024" + ] + }, + "signalCount": 2 + }, + { + "unit": "M4203_A", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC011", + "pos": [ + 329374.5, + 451610.1 + ], + "io": { + "motorProtection": [ + "FC0147" + ], + "sensorInSep": [ + "BG3120" + ], + "sensorCarrInPos": [ + "BG3121" + ], + "sensorConvFull": [ + "BG3123" + ], + "sensorJam": [ + "BG3124", + "BG3144" + ], + "motorOutput": [ + "MA0147" + ], + "stopperOutput": [ + "MB3120" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4203_B", + "unitKind": "CV", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": null, + "pos": [ + 331346.9, + 452690.1 + ], + "io": { + "motorProtection": [ + "FC0153" + ], + "sensorConvFull": [ + "BG3146" + ], + "sensorJam": [ + "BG3147" + ], + "motorOutput": [ + "MA0153" + ] + }, + "signalCount": 4 + }, + { + "unit": "M4204", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep1Swi", + "areas": [], + "cabinet": "UC011", + "pos": [ + 329374.5, + 453500.1 + ], + "io": { + "motorProtection": [ + "FC0140" + ], + "sensorWheel": [ + "BG3007" + ], + "sensorInSep": [ + "BG3010", + "BG3013" + ], + "sensorJam": [ + "BG3012", + "BG3014", + "BG3015", + "BG3016" + ], + "motorOutput": [ + "MA0140" + ], + "stopperOutput": [ + "MB3010", + "MB3013" + ], + "switchOutput": [ + "MB3015" + ] + }, + "signalCount": 12 + }, + { + "unit": "M4302", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC1103", + "pos": [ + 338356.4, + 449090.6 + ], + "io": { + "sensorInSep": [ + "BG3125" + ], + "stopperOutput": [ + "MB3125" + ] + }, + "signalCount": 2 + }, + { + "unit": "M4302_A", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC1103", + "pos": [ + 331346.9, + 452420.1 + ], + "io": { + "motorProtection": [ + "FC0154" + ], + "sensorFinger": [ + "BG3122" + ], + "sensorJam": [ + "BG3150", + "BG3153" + ], + "sensorConvFull": [ + "BG3152" + ], + "motorOutput": [ + "MA0154" + ] + }, + "signalCount": 6 + }, + { + "unit": "M4302_B", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC011", + "pos": [ + 331328.7, + 453508.3 + ], + "io": { + "motorProtection": [ + "FC0150" + ], + "sensorJam": [ + "BG3126" + ], + "sensorConvFull": [ + "BG3127" + ], + "sensorInSep": [ + "BG3130" + ], + "sensorCarrInPos": [ + "BG3131" + ], + "sensorFinger": [ + "BG3132" + ], + "motorOutput": [ + "MA0150" + ], + "stopperOutput": [ + "MB3130" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4402_A", + "unitKind": "CV", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": null, + "pos": null, + "io": { + "motorProtection": [ + "FC0155" + ], + "sensorJam": [ + "BG3154", + "BG3157" + ], + "sensorConvFull": [ + "BG3156" + ], + "motorOutput": [ + "MA0155" + ] + }, + "signalCount": 5 + }, + { + "unit": "M4402_B", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC011", + "pos": [ + 331346.9, + 453230.1 + ], + "io": { + "motorProtection": [ + "FC0151" + ], + "sensorConvFull": [ + "BG3133" + ], + "sensorJam": [ + "BG3134" + ], + "sensorInSep": [ + "BG3135" + ], + "sensorCarrInPos": [ + "BG3136" + ], + "sensorFinger": [ + "BG3137" + ], + "motorOutput": [ + "MA0151" + ], + "stopperOutput": [ + "MB3135" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4403", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC011", + "pos": [ + 329374.5, + 452690.1 + ], + "io": { + "motorProtection": [ + "FC0143" + ], + "sensorConvFull": [ + "BG3070" + ], + "sensorJam": [ + "BG3071" + ], + "sensorInSep": [ + "BG3073" + ], + "sensorCarrInPos": [ + "BG3074" + ], + "sensorFinger": [ + "BG3075" + ], + "motorOutput": [ + "MA0143" + ], + "stopperOutput": [ + "MB3073" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4501", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC011", + "pos": [ + 329370.7, + 452418.5 + ], + "io": { + "motorProtection": [ + "FC0144" + ], + "sensorCarrInPos": [ + "BG3011" + ], + "sensorJam": [ + "BG3017", + "BG3022" + ], + "sensorInSep": [ + "BG3020" + ], + "sensorFinger": [ + "BG3021" + ], + "sensorConvFull": [ + "BG3023" + ], + "motorOutput": [ + "MA0144" + ], + "stopperOutput": [ + "MB3020" + ] + }, + "signalCount": 9 + }, + { + "unit": "M4502", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC011", + "pos": [ + 329374.5, + 452960.1 + ], + "io": { + "motorProtection": [ + "FC0142" + ], + "sensorInSep": [ + "BG3063" + ], + "sensorCarrInPos": [ + "BG3064" + ], + "sensorFinger": [ + "BG3065" + ], + "sensorConvFull": [ + "BG3066" + ], + "sensorJam": [ + "BG3067" + ], + "motorOutput": [ + "MA0142" + ], + "stopperOutput": [ + "MB3063" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4503", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC011", + "pos": [ + 329374.5, + 453230.1 + ], + "io": { + "motorProtection": [ + "FC0141" + ], + "sensorInSep": [ + "BG3060", + "BG3080" + ], + "sensorJam": [ + "BG3061" + ], + "sensorConvFull": [ + "BG3062" + ], + "sensorFinger": [ + "BG3081" + ], + "sensorCarrInPos": [ + "BG3082" + ], + "motorOutput": [ + "MA0141" + ], + "stopperOutput": [ + "MB3060", + "MB3080" + ] + }, + "signalCount": 10 + }, + { + "unit": "PM0103", + "unitKind": "CV", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": "UH01", + "pos": [ + 331179.0, + 165151.7 + ], + "io": { + "motorOutput": [ + "MA0062" + ] + }, + "signalCount": 1 + } + ], + "areas": [ + { + "id": "Block 1.1", + "kind": "pinStoreBlock", + "members": [], + "cabinets": [ + "UC0101", + "UC0102" + ] + }, + { + "id": "Block 1.2", + "kind": "pinStoreBlock", + "members": [], + "cabinets": [ + "UC0101", + "UC0102" + ] + }, + { + "id": "LS1", + "kind": "loadingStation", + "members": [ + "M0101" + ], + "cabinets": [ + "UC0101", + "UC0110", + "UC0111", + "UH01" + ] + }, + { + "id": "LS2", + "kind": "loadingStation", + "members": [ + "M0101" + ], + "cabinets": [ + "UC0101", + "UC0111", + "UH01" + ] + }, + { + "id": "UZ0101", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0102", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0103", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0104", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0110", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0111", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ1101", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ1103", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ1104", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ1105", + "kind": "safetyZone", + "members": [], + "cabinets": [] + } + ], + "unassignedSignals": [ + "BG3301", + "BG3343", + "BG3344", + "BG3345", + "BG3346", + "BG3357", + "BG4740", + "BG5060", + "BP0004", + "BP0107", + "DI0005", + "DI0006", + "DI0007", + "DI0010", + "DI0011", + "DI0012", + "DI0013", + "DI0014", + "DI0016", + "DI0017", + "DI0021", + "DI0022", + "DI0023", + "DI0024", + "DI0034", + "DI0035", + "DI0036", + "DI0037", + "DI0042", + "DI0047", + "DI0100", + "DI0101", + "DI0102", + "DI0106", + "DI0110", + "DI0111", + "DI0112", + "DI0114", + "DQ0042", + "DQ0047", + "MB0282", + "MB0342", + "PF0000", + "PF0001", + "PF0002", + "PF0003", + "PF0004", + "PF0005", + "PF0006", + "PF0020", + "PF0021", + "PF0022", + "PF0023", + "PF0024", + "PF0044", + "PF0055", + "PF0100", + "PF0101", + "PF0102", + "PF0117", + "PF0287", + "PF0347", + "QA0012", + "QA0013", + "QA0610", + "QA0611", + "QA0612", + "QA0613", + "QA0660", + "QA0661", + "QA0662", + "QA0663", + "QA0920", + "QA0921", + "QA0922", + "QA0923", + "SF0000", + "SF0001", + "SF0002", + "SF0003", + "SF0050", + "SF0051", + "SF0052", + "SF0053", + "SF0117", + "SF0306", + "SF0322", + "SF0323", + "SF0366", + "SF0382", + "SF0383", + "SF0400", + "SF0404", + "SF0471", + "SF0475", + "SF0710", + "SF0714", + "SF0781", + "SF0785" + ], + "todo": [ + "topology[] aus connect-Daten uebernommen — TRO-IDs den Einheiten (units[]) noch zuordnen", + "Timings, Priority, Release, customCode manuell pflegen" + ], + "topology": { + "format": "hmf-connect-v1", + "tros": [ + { + "id": "TRO100", + "fbType": "1Sep", + "comment": "TRO 100 (1Sep)", + "entries": [ + { + "jamArea": "JA0100_1", + "dbRef": "\"DB_JamArea0100\".stJam0100_1", + "from": "TRO128", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA0101_1", + "dbRef": "\"DB_JamArea0101\".stJam0101_1", + "to": "TRO101_IN", + "kind": "normal" + } + ] + }, + { + "id": "TRO101", + "fbType": "EmptyCarrBuffer", + "comment": "TRO101 (Empty Buffer rechts)", + "entries": [ + { + "jamArea": "JamBuffer101", + "dbRef": "JamBuffer101", + "from": "TRO101_IN", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0102_2", + "dbRef": "\"DB_JamArea0102\".stJam0102_2", + "to": "TRO112", + "kind": "normal" + } + ] + }, + { + "id": "TRO101_IN", + "fbType": "1Sep", + "comment": "TRO 101_IN(1Sep)", + "entries": [ + { + "jamArea": "JA0101_1", + "dbRef": "\"DB_JamArea0101\".stJam0101_1", + "from": "TRO100", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0101_2", + "dbRef": "\"DB_JamArea0101\".stJam0101_2", + "to": "TRO102_IN", + "kind": "normal" + }, + { + "jamArea": "JamBuffer101", + "dbRef": "JamBuffer101", + "to": "TRO101", + "kind": "normal" + } + ] + }, + { + "id": "TRO102", + "fbType": "EmptyCarrBuffer", + "comment": "TRO102 (Empty Buffer links)", + "entries": [ + { + "jamArea": "JamBuffer102", + "dbRef": "JamBuffer102", + "from": "TRO102_IN", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0102_1", + "dbRef": "\"DB_JamArea0102\".stJam0102_1", + "to": "TRO107", + "kind": "normal" + } + ] + }, + { + "id": "TRO102_IN", + "fbType": "1Sep", + "comment": "TRO 102_IN(1Sep)", + "entries": [ + { + "jamArea": "JA0101_2", + "dbRef": "\"DB_JamArea0101\".stJam0101_2", + "from": "TRO101_IN", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JamBuffer102", + "dbRef": "JamBuffer102", + "to": "TRO102", + "kind": "normal" + } + ] + }, + { + "id": "TRO103", + "fbType": "1Sep", + "comment": "TRO 103 (1Sep)", + "entries": [ + { + "jamArea": "JA0103_1", + "dbRef": "\"DB_JamArea0103\".stJam0103_1", + "from": "TRO107", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0104_1", + "dbRef": "\"DB_JamArea0104\".stJam0104_1", + "to": "TRO104", + "kind": "normal" + } + ] + }, + { + "id": "TRO104", + "fbType": "1Sep", + "comment": "TRO 104 (1Sep)+Scanner", + "entries": [ + { + "jamArea": "JA0104_1", + "dbRef": "\"DB_JamArea0104\".stJam0104_1", + "from": "TRO103", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0104_2", + "dbRef": "\"DB_JamArea0104\".stJam0104_2", + "to": "fbLoadingBoom1", + "kind": "normal" + } + ] + }, + { + "id": "TRO105", + "fbType": "1Sep_SSCC", + "comment": "TRO 105 (1Sep)+Scanner", + "entries": [ + { + "jamArea": "JA0104_3", + "dbRef": "\"DB_JamArea0104\".stJam0104_3", + "from": "fbLoadingBoom1", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0106_2", + "dbRef": "\"DB_JamArea0106\".stJam0106_2", + "to": "TRO106", + "kind": "normal" + } + ] + }, + { + "id": "TRO106", + "fbType": "1Sep", + "comment": "TRO 106 (1Sep)", + "entries": [ + { + "jamArea": "JA0106_2", + "dbRef": "\"DB_JamArea0106\".stJam0106_2", + "from": "TRO105", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0102_2", + "dbRef": "\"DB_JamArea0102\".stJam0102_2", + "to": "TRO112", + "kind": "normal" + } + ] + }, + { + "id": "TRO107", + "fbType": "1Sep1Swi", + "comment": "TRO 107(1Sep1Swi)", + "entries": [ + { + "jamArea": "JA0102_1", + "dbRef": "\"DB_JamArea0102\".stJam0102_1", + "from": "TRO102", + "kind": "normal" + }, + { + "jamArea": "JA0102_1", + "dbRef": "\"DB_JamArea0102\".stJam0102_1", + "from": "TRO117", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0102_2", + "dbRef": "\"DB_JamArea0102\".stJam0102_2", + "to": "TRO112", + "kind": "dir2" + }, + { + "jamArea": "JA0103_1", + "dbRef": "\"DB_JamArea0103\".stJam0103_1", + "to": "TRO103", + "kind": "normal" + } + ] + }, + { + "id": "TRO108", + "fbType": "1Sep", + "comment": "TRO 108 (1Sep)", + "entries": [ + { + "jamArea": "JA0107_1", + "dbRef": "\"DB_JamArea0107\".stJam0107_1", + "from": "TRO112", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0108_1", + "dbRef": "\"DB_JamArea0108\".stJam0108_1", + "to": "TRO109", + "kind": "normal" + } + ] + }, + { + "id": "TRO109", + "fbType": "1Sep", + "comment": "TRO 109 (1Sep)+Scanner", + "entries": [ + { + "jamArea": "JA0108_1", + "dbRef": "\"DB_JamArea0108\".stJam0108_1", + "from": "TRO108", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0108_2", + "dbRef": "\"DB_JamArea0108\".stJam0108_2", + "to": "fbLoadingBoom2", + "kind": "normal" + } + ] + }, + { + "id": "TRO110", + "fbType": "1Sep_SSCC", + "comment": "TRO 110 (1Sep)+Scanner", + "entries": [ + { + "jamArea": "JA0108_3", + "dbRef": "\"DB_JamArea0108\".stJam0108_3", + "from": "fbLoadingBoom2", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0110_2", + "dbRef": "\"DB_JamArea0110\".stJam0110_2", + "to": "TRO111", + "kind": "normal" + } + ] + }, + { + "id": "TRO111", + "fbType": "1Sep", + "comment": "TRO 111 (1Sep)", + "entries": [ + { + "jamArea": "JA0110_2", + "dbRef": "\"DB_JamArea0110\".stJam0110_2", + "from": "TRO110", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0102_3", + "dbRef": "\"DB_JamArea0102\".stJam0102_3", + "to": "TRO113", + "kind": "normal" + } + ] + }, + { + "id": "TRO112", + "fbType": "1Sep1Swi", + "comment": "TRO 112 (1Sep1Swi)", + "entries": [ + { + "jamArea": "JA0102_2", + "dbRef": "\"DB_JamArea0102\".stJam0102_2", + "from": "TRO101", + "kind": "normal" + }, + { + "jamArea": "JA0102_2", + "dbRef": "\"DB_JamArea0102\".stJam0102_2", + "from": "TRO106", + "kind": "normal" + }, + { + "jamArea": "JA0102_2", + "dbRef": "\"DB_JamArea0102\".stJam0102_2", + "from": "TRO107", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA0102_3", + "dbRef": "\"DB_JamArea0102\".stJam0102_3", + "to": "TRO113", + "kind": "dir2" + }, + { + "jamArea": "JA0107_1", + "dbRef": "\"DB_JamArea0107\".stJam0107_1", + "to": "TRO108", + "kind": "normal" + } + ] + }, + { + "id": "TRO113", + "fbType": "1Sep", + "comment": "TRO 113 (1Sep)+Scanner", + "entries": [ + { + "jamArea": "JA0102_3", + "dbRef": "\"DB_JamArea0102\".stJam0102_3", + "from": "TRO111", + "kind": "normal" + }, + { + "jamArea": "JA0102_3", + "dbRef": "\"DB_JamArea0102\".stJam0102_3", + "from": "TRO112", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA0102_4", + "dbRef": "\"DB_JamArea0102\".stJam0102_4", + "to": "TRO114", + "kind": "normal" + } + ] + }, + { + "id": "TRO114", + "fbType": "1Sep1Swi", + "comment": "TRO 114 (1Sep1Switch)+Scanner", + "entries": [ + { + "jamArea": "JA0102_4", + "dbRef": "\"DB_JamArea0102\".stJam0102_4", + "from": "TRO113", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0102_5", + "dbRef": "\"DB_JamArea0102\".stJam0102_5", + "to": "TRO116", + "kind": "dir2" + } + ] + }, + { + "id": "TRO115", + "fbType": "Vario", + "comment": "TRO 115 (Vario)", + "entries": [ + { + "jamArea": "JA4104_1", + "dbRef": "\"DB_JamArea4104\".stJam4104_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA4103_1", + "dbRef": "\"DB_JamArea4103\".stJam4103_1", + "to": "TRO120", + "kind": "finger" + } + ] + }, + { + "id": "TRO116", + "fbType": "1Sep", + "comment": "TRO 116 (1Sep)", + "entries": [ + { + "jamArea": "JA0102_5", + "dbRef": "\"DB_JamArea0102\".stJam0102_5", + "from": "TRO114", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA0102_6", + "dbRef": "\"DB_JamArea0102\".stJam0102_6", + "to": "TRO117", + "kind": "normal" + } + ] + }, + { + "id": "TRO117", + "fbType": "1Sep", + "comment": "TRO 117 (1Sep) + Scanner", + "entries": [ + { + "jamArea": "JA0102_6", + "dbRef": "\"DB_JamArea0102\".stJam0102_6", + "from": "TRO116", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0102_1", + "dbRef": "\"DB_JamArea0102\".stJam0102_1", + "to": "TRO107", + "kind": "normal" + } + ] + }, + { + "id": "TRO120", + "fbType": "Vario", + "comment": "TRO 120 (Vario)", + "entries": [ + { + "jamArea": "JA4103_1", + "dbRef": "\"DB_JamArea4103\".stJam4103_1", + "from": "TRO115", + "kind": "finger" + } + ], + "exits": [] + }, + { + "id": "TRO121", + "fbType": "Vario", + "comment": "TRO 121(Vario)", + "entries": [ + { + "jamArea": "JA4503_1", + "dbRef": "\"DB_JamArea4503\".stJam4503_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA4503_2", + "dbRef": "\"DB_JamArea4503\".stJam4503_2", + "to": "TRO122", + "kind": "finger" + } + ] + }, + { + "id": "TRO122", + "fbType": "1Sep", + "comment": "TRO 122 (1Sep)", + "entries": [ + { + "jamArea": "JA4503_2", + "dbRef": "\"DB_JamArea4503\".stJam4503_2", + "from": "TRO121", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA4502_1", + "dbRef": "\"DB_JamArea4502\".stJam4502_1", + "to": "TRO123", + "kind": "normal" + } + ] + }, + { + "id": "TRO123", + "fbType": "Vario", + "comment": "TRO 123 (Vario)", + "entries": [ + { + "jamArea": "JA4502_1", + "dbRef": "\"DB_JamArea4502\".stJam4502_1", + "from": "TRO122", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4502_2", + "dbRef": "\"DB_JamArea4502\".stJam4502_2", + "to": "TRO124", + "kind": "finger" + } + ] + }, + { + "id": "TRO124", + "fbType": "1Sep1Swi", + "comment": "TRO 124 (1Sep1Switch)", + "entries": [ + { + "jamArea": "JA4502_2", + "dbRef": "\"DB_JamArea4502\".stJam4502_2", + "from": "TRO123", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA4204_2", + "dbRef": "\"DB_JamArea4204\".stJam4204_2", + "to": "TRO125", + "kind": "normal" + }, + { + "jamArea": "JA4501_1", + "dbRef": "\"DB_JamArea4501\".stJam4501_1", + "to": "TRO127", + "kind": "dir2" + } + ] + }, + { + "id": "TRO125", + "fbType": "1Sep", + "comment": "TRO 125 (1Sep)", + "entries": [ + { + "jamArea": "JA4204_2", + "dbRef": "\"DB_JamArea4204\".stJam4204_2", + "from": "TRO124", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4203_1", + "dbRef": "\"DB_JamArea4203\".stJam4203_1", + "to": "TRO126", + "kind": "normal" + } + ] + }, + { + "id": "TRO126", + "fbType": "Vario", + "comment": "TRO 126 (Vario)", + "entries": [ + { + "jamArea": "JA4203_1", + "dbRef": "\"DB_JamArea4203\".stJam4203_1", + "from": "TRO125", + "kind": "normal" + } + ], + "exits": [] + }, + { + "id": "TRO127", + "fbType": "Vario", + "comment": "TRO 127 (Vario)", + "entries": [ + { + "jamArea": "JA4501_1", + "dbRef": "\"DB_JamArea4501\".stJam4501_1", + "from": "TRO124", + "kind": "dir2" + }, + { + "jamArea": "JA4501_1", + "dbRef": "\"DB_JamArea4501\".stJam4501_1", + "from": "TRO130", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4501_2", + "dbRef": "\"DB_JamArea4501\".stJam4501_2", + "to": "TRO128", + "kind": "finger" + } + ] + }, + { + "id": "TRO128", + "fbType": "Vario", + "comment": "TRO 128 (Vario)", + "entries": [ + { + "jamArea": "JA4501_2", + "dbRef": "\"DB_JamArea4501\".stJam4501_2", + "from": "TRO127", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA0100_1", + "dbRef": "\"DB_JamArea0100\".stJam0100_1", + "to": "TRO100", + "kind": "finger" + } + ] + }, + { + "id": "TRO129", + "fbType": "1Sep", + "comment": "TRO 129 (1Sep)", + "entries": [ + { + "jamArea": "JA4302_2", + "dbRef": "\"DB_JamArea4302\".stJam4302_2", + "from": "TRO133", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA4204_1", + "dbRef": "\"DB_JamArea4204\".stJam4204_1", + "to": "TRO130", + "kind": "normal" + } + ] + }, + { + "id": "TRO130", + "fbType": "1Sep", + "comment": "TRO 130 (1Sep)", + "entries": [ + { + "jamArea": "JA4204_1", + "dbRef": "\"DB_JamArea4204\".stJam4204_1", + "from": "TRO129", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4501_1", + "dbRef": "\"DB_JamArea4501\".stJam4501_1", + "to": "TRO127", + "kind": "normal" + } + ] + }, + { + "id": "TRO131", + "fbType": "Vario", + "comment": "TRO 131 (Vario)", + "entries": [ + { + "jamArea": "JA4403_1", + "dbRef": "\"DB_JamArea4403\".stJam4403_1", + "from": "TRO134", + "kind": "finger" + } + ], + "exits": [] + }, + { + "id": "TRO133", + "fbType": "Vario", + "comment": "TRO 133 (Vario)", + "entries": [ + { + "jamArea": "JA4302_1", + "dbRef": "\"DB_JamArea4302\".stJam4302_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA4302_2", + "dbRef": "\"DB_JamArea4302\".stJam4302_2", + "to": "TRO129", + "kind": "finger" + } + ] + }, + { + "id": "TRO134", + "fbType": "Vario", + "comment": "TRO 134 (Vario)", + "entries": [ + { + "jamArea": "JA4402_1", + "dbRef": "\"DB_JamArea4402\".stJam4402_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA4403_1", + "dbRef": "\"DB_JamArea4403\".stJam4403_1", + "to": "TRO131", + "kind": "finger" + } + ] + }, + { + "id": "fbLoadingBoom1", + "fbType": "LoadingBoom_INBOUND", + "comment": "LoadingBoom 1", + "entries": [ + { + "jamArea": "JA0104_2", + "dbRef": "\"DB_JamArea0104\".stJam0104_2", + "from": "TRO104", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0104_3", + "dbRef": "\"DB_JamArea0104\".stJam0104_3", + "to": "TRO105", + "kind": "normal" + } + ] + }, + { + "id": "fbLoadingBoom2", + "fbType": "LoadingBoom_INBOUND", + "comment": "LoadingBoom 2", + "entries": [ + { + "jamArea": "JA0108_2", + "dbRef": "\"DB_JamArea0108\".stJam0108_2", + "from": "TRO109", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA0108_3", + "dbRef": "\"DB_JamArea0108\".stJam0108_3", + "to": "TRO110", + "kind": "normal" + } + ] + } + ], + "connections": [ + { + "from": "TRO128", + "to": "TRO100", + "jamArea": "JA0100_1", + "kind": "finger", + "dbRef": "\"DB_JamArea0100\".stJam0100_1" + }, + { + "from": "TRO100", + "to": "TRO101_IN", + "jamArea": "JA0101_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0101\".stJam0101_1" + }, + { + "from": "TRO101_IN", + "to": "TRO102_IN", + "jamArea": "JA0101_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0101\".stJam0101_2" + }, + { + "from": "TRO102", + "to": "TRO107", + "jamArea": "JA0102_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_1" + }, + { + "from": "TRO117", + "to": "TRO107", + "jamArea": "JA0102_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_1" + }, + { + "from": "TRO101", + "to": "TRO112", + "jamArea": "JA0102_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_2" + }, + { + "from": "TRO106", + "to": "TRO112", + "jamArea": "JA0102_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_2" + }, + { + "from": "TRO107", + "to": "TRO112", + "jamArea": "JA0102_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea0102\".stJam0102_2" + }, + { + "from": "TRO111", + "to": "TRO113", + "jamArea": "JA0102_3", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_3" + }, + { + "from": "TRO112", + "to": "TRO113", + "jamArea": "JA0102_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea0102\".stJam0102_3" + }, + { + "from": "TRO113", + "to": "TRO114", + "jamArea": "JA0102_4", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_4" + }, + { + "from": "TRO114", + "to": "TRO116", + "jamArea": "JA0102_5", + "kind": "dir2", + "dbRef": "\"DB_JamArea0102\".stJam0102_5" + }, + { + "from": "TRO116", + "to": "TRO117", + "jamArea": "JA0102_6", + "kind": "normal", + "dbRef": "\"DB_JamArea0102\".stJam0102_6" + }, + { + "from": "TRO107", + "to": "TRO103", + "jamArea": "JA0103_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0103\".stJam0103_1" + }, + { + "from": "TRO103", + "to": "TRO104", + "jamArea": "JA0104_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0104\".stJam0104_1" + }, + { + "from": "TRO104", + "to": "fbLoadingBoom1", + "jamArea": "JA0104_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0104\".stJam0104_2" + }, + { + "from": "fbLoadingBoom1", + "to": "TRO105", + "jamArea": "JA0104_3", + "kind": "normal", + "dbRef": "\"DB_JamArea0104\".stJam0104_3" + }, + { + "from": "TRO105", + "to": "TRO106", + "jamArea": "JA0106_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0106\".stJam0106_2" + }, + { + "from": "TRO112", + "to": "TRO108", + "jamArea": "JA0107_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0107\".stJam0107_1" + }, + { + "from": "TRO108", + "to": "TRO109", + "jamArea": "JA0108_1", + "kind": "normal", + "dbRef": "\"DB_JamArea0108\".stJam0108_1" + }, + { + "from": "TRO109", + "to": "fbLoadingBoom2", + "jamArea": "JA0108_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0108\".stJam0108_2" + }, + { + "from": "fbLoadingBoom2", + "to": "TRO110", + "jamArea": "JA0108_3", + "kind": "normal", + "dbRef": "\"DB_JamArea0108\".stJam0108_3" + }, + { + "from": "TRO110", + "to": "TRO111", + "jamArea": "JA0110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea0110\".stJam0110_2" + }, + { + "from": "TRO115", + "to": "TRO120", + "jamArea": "JA4103_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4103\".stJam4103_1" + }, + { + "from": "TRO125", + "to": "TRO126", + "jamArea": "JA4203_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4203\".stJam4203_1" + }, + { + "from": "TRO129", + "to": "TRO130", + "jamArea": "JA4204_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4204\".stJam4204_1" + }, + { + "from": "TRO124", + "to": "TRO125", + "jamArea": "JA4204_2", + "kind": "normal", + "dbRef": "\"DB_JamArea4204\".stJam4204_2" + }, + { + "from": "TRO133", + "to": "TRO129", + "jamArea": "JA4302_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4302\".stJam4302_2" + }, + { + "from": "TRO134", + "to": "TRO131", + "jamArea": "JA4403_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4403\".stJam4403_1" + }, + { + "from": "TRO124", + "to": "TRO127", + "jamArea": "JA4501_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea4501\".stJam4501_1" + }, + { + "from": "TRO130", + "to": "TRO127", + "jamArea": "JA4501_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4501\".stJam4501_1" + }, + { + "from": "TRO127", + "to": "TRO128", + "jamArea": "JA4501_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4501\".stJam4501_2" + }, + { + "from": "TRO122", + "to": "TRO123", + "jamArea": "JA4502_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4502\".stJam4502_1" + }, + { + "from": "TRO123", + "to": "TRO124", + "jamArea": "JA4502_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4502\".stJam4502_2" + }, + { + "from": "TRO121", + "to": "TRO122", + "jamArea": "JA4503_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4503\".stJam4503_2" + }, + { + "from": "TRO101_IN", + "to": "TRO101", + "jamArea": "JamBuffer101", + "kind": "normal", + "dbRef": "JamBuffer101" + }, + { + "from": "TRO102_IN", + "to": "TRO102", + "jamArea": "JamBuffer102", + "kind": "normal", + "dbRef": "JamBuffer102" + } + ], + "externals": [ + { + "node": "TRO115", + "direction": "in", + "jamArea": "JA4104_1", + "dbRef": "\"DB_JamArea4104\".stJam4104_1" + }, + { + "node": "TRO133", + "direction": "in", + "jamArea": "JA4302_1", + "dbRef": "\"DB_JamArea4302\".stJam4302_1" + }, + { + "node": "TRO134", + "direction": "in", + "jamArea": "JA4402_1", + "dbRef": "\"DB_JamArea4402\".stJam4402_1" + }, + { + "node": "TRO121", + "direction": "in", + "jamArea": "JA4503_1", + "dbRef": "\"DB_JamArea4503\".stJam4503_1" + } + ] + } +} \ No newline at end of file diff --git a/results/skeleton_UH02.json b/results/skeleton_UH02.json new file mode 100644 index 0000000..6373fee --- /dev/null +++ b/results/skeleton_UH02.json @@ -0,0 +1,16745 @@ +{ + "$schema": "hmf-layout-v1.schema.json", + "generatedBy": "create_skel.py", + "plc": { + "id": "UH02", + "configName": "=A01+UH02-KF00" + }, + "statistics": { + "tags": 1578, + "sensors": 924, + "constants": 1578, + "units": 48, + "areas": 39, + "unassignedSignals": 118, + "troNodes": 74, + "connections": 88, + "externals": 25 + }, + "sensors": [ + { + "id": "SF0000", + "constant": "cInSF0000", + "hwAddress": "%E000.0", + "comment": "DT Anlage Aus", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 288443.2 + ] + }, + { + "id": "SF0001", + "constant": "cInSF0001", + "hwAddress": "%E000.1", + "comment": "LDT Anlage Ein", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 288173.2 + ] + }, + { + "id": "SF0002", + "constant": "cInSF0002", + "hwAddress": "%E000.2", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 287903.2 + ] + }, + { + "id": "SF0003", + "constant": "cInSF0003", + "hwAddress": "%E000.3", + "comment": "DT Lampentest", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 287633.2 + ] + }, + { + "id": "BP0004", + "constant": "cInBP0004", + "hwAddress": "%E000.4", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UH02", + "pos": [ + 250893.4, + 289544.3 + ] + }, + { + "id": "DI0005", + "constant": "cInDI0005", + "hwAddress": "%E000.5", + "comment": "Phasenausfall 400V", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 284888.1 + ] + }, + { + "id": "DI0006", + "constant": "cInDI0006", + "hwAddress": "%E000.6", + "comment": "Vorsicherung 400V UC021", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 284618.1 + ] + }, + { + "id": "DI0007", + "constant": "cInDI0007", + "hwAddress": "%E000.7", + "comment": "Vorsicherung 400V UC022", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 284348.1 + ] + }, + { + "id": "DI0010", + "constant": "cInDI0010", + "hwAddress": "%E001.0", + "comment": "Vorsicherung 400V UC023", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 284078.1 + ] + }, + { + "id": "DI0011", + "constant": "cInDI0011", + "hwAddress": "%E001.1", + "comment": "Vorsicherung 400V UC Reserve", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 283808.1 + ] + }, + { + "id": "DI0012", + "constant": "cInDI0012", + "hwAddress": "%E001.2", + "comment": "Vorsicherung 400V UC Reserve", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 283538.1 + ] + }, + { + "id": "DI0013", + "constant": "cInDI0013", + "hwAddress": "%E001.3", + "comment": "Feedback Hauptschütze aktiv", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 279796.0 + ] + }, + { + "id": "DI0014", + "constant": "cInDI0014", + "hwAddress": "%E001.4", + "comment": "Feedback Koppelrelais E-Stop-IF UH03 (QA0660/QA0661)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 278680.3 + ] + }, + { + "id": "DI0015", + "constant": "cInDI0015", + "hwAddress": "%E001.5", + "comment": "Feedback Koppelrelais E-Stop-IF", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 277185.3 + ] + }, + { + "id": "DI0016", + "constant": "cInDI0016", + "hwAddress": "%E001.6", + "comment": "Sicherungsautomatenfall", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 283268.1 + ] + }, + { + "id": "DI0021", + "constant": "cInDI0021", + "hwAddress": "%E002.1", + "comment": "Vorsicherung 24V OK (FC021)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 282940.8 + ] + }, + { + "id": "DI0022", + "constant": "cInDI0022", + "hwAddress": "%E002.2", + "comment": "Vorsicherung 24V OK (FC022)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 282670.8 + ] + }, + { + "id": "DI0023", + "constant": "cInDI0023", + "hwAddress": "%E002.3", + "comment": "Vorsicherung 24V OK (FC023)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 282400.8 + ] + }, + { + "id": "DI0024", + "constant": "cInDI0024", + "hwAddress": "%E002.4", + "comment": "Vorsicherung 24V OK (FC024)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 282130.8 + ] + }, + { + "id": "DI0025", + "constant": "cInDI0025", + "hwAddress": "%E002.5", + "comment": "Vorsicherung 24V OK (FC025)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 281860.8 + ] + }, + { + "id": "DI0026", + "constant": "cInDI0026", + "hwAddress": "%E002.6", + "comment": "Vorsicherung 24V OK (FC026)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 281590.8 + ] + }, + { + "id": "DI0034", + "constant": "cInDI0034", + "hwAddress": "%E003.4", + "comment": "IF BMZ \"fire alarm\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252901.1, + 272710.4 + ] + }, + { + "id": "DI0035", + "constant": "cInDI0035", + "hwAddress": "%E003.5", + "comment": "IF BST \"No fire alarm\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 281230.9 + ] + }, + { + "id": "DI0036", + "constant": "cInDI0036", + "hwAddress": "%E003.6", + "comment": "IF BST \"Non fault\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 280960.9 + ] + }, + { + "id": "DI0037", + "constant": "cInDI0037", + "hwAddress": "%E003.7", + "comment": "IF BST \"FPC opened\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 280690.9 + ] + }, + { + "id": "SF0040", + "constant": "cInSF0040", + "hwAddress": "%E004.0", + "comment": "Bereichshalt UZ0201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180254.6, + 290688.2 + ] + }, + { + "id": "SF0041", + "constant": "cInSF0041", + "hwAddress": "%E004.1", + "comment": "Reset UZ0201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180258.1, + 290421.1 + ] + }, + { + "id": "SF0042", + "constant": "cInSF0042", + "hwAddress": "%E004.2", + "comment": "Bereichshalt UZ0202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 195114.2, + 290848.3 + ] + }, + { + "id": "SF0043", + "constant": "cInSF0043", + "hwAddress": "%E004.3", + "comment": "Reset UZ0202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 195117.7, + 290581.2 + ] + }, + { + "id": "SF0044", + "constant": "cInSF0044", + "hwAddress": "%E004.4", + "comment": "Bereichshalt UZ0203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212642.4, + 290804.7 + ] + }, + { + "id": "SF0045", + "constant": "cInSF0045", + "hwAddress": "%E004.5", + "comment": "Reset UZ0203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212642.4, + 290534.7 + ] + }, + { + "id": "SF0046", + "constant": "cInSF0046", + "hwAddress": "%E004.6", + "comment": "Bereichshalt UZ0204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 238287.3, + 289990.9 + ] + }, + { + "id": "SF0047", + "constant": "cInSF0047", + "hwAddress": "%E004.7", + "comment": "Reset UZ0204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 238287.3, + 289720.9 + ] + }, + { + "id": "SF0050", + "constant": "cInSF0050", + "hwAddress": "%E005.0", + "comment": "Bereichshalt UZ0205", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 183867.3, + 289514.4 + ] + }, + { + "id": "SF0051", + "constant": "cInSF0051", + "hwAddress": "%E005.1", + "comment": "Reset UZ0205", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 183867.3, + 289244.4 + ] + }, + { + "id": "SF0052", + "constant": "cInSF0052", + "hwAddress": "%E005.2", + "comment": "Bereichshalt UZ0206", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200159.8, + 289456.9 + ] + }, + { + "id": "SF0053", + "constant": "cInSF0053", + "hwAddress": "%E005.3", + "comment": "Reset UZ0206", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200159.8, + 289198.9 + ] + }, + { + "id": "SF0054", + "constant": "cInSF0054", + "hwAddress": "%E005.4", + "comment": "Bereichshalt UZ0207", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 221690.1, + 289434.8 + ] + }, + { + "id": "SF0055", + "constant": "cInSF0055", + "hwAddress": "%E005.5", + "comment": "Reset UZ0207", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 221690.1, + 289164.8 + ] + }, + { + "id": "SF0056", + "constant": "cInSF0056", + "hwAddress": "%E005.6", + "comment": "Bereichshalt UZ0208", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234637.1, + 288966.0 + ] + }, + { + "id": "SF0057", + "constant": "cInSF0057", + "hwAddress": "%E005.7", + "comment": "Reset UZ0208", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234637.1, + 288696.0 + ] + }, + { + "id": "FC0060", + "constant": "cInFC0060", + "hwAddress": "%E006.0", + "comment": "MSS ausgelöst FC0060 (KR-M1103)", + "role": "motorProtection", + "unit": "M1103", + "cabinet": null, + "pos": [ + 252775.2, + 275540.0 + ] + }, + { + "id": "FC0061", + "constant": "cInFC0061", + "hwAddress": "%E006.1", + "comment": "MSS ausgelöst FC0061 (KR-M1104)", + "role": "motorProtection", + "unit": "M1104", + "cabinet": null, + "pos": [ + 252775.2, + 275270.0 + ] + }, + { + "id": "FC0062", + "constant": "cInFC0062", + "hwAddress": "%E006.2", + "comment": "MSS ausgelöst FC0062 (KR-M1201)", + "role": "motorProtection", + "unit": "M1201", + "cabinet": null, + "pos": [ + 252775.2, + 275000.0 + ] + }, + { + "id": "FC0063", + "constant": "cInFC0063", + "hwAddress": "%E006.3", + "comment": "MSS ausgelöst FC0063 (KR-M1202)", + "role": "motorProtection", + "unit": "M1202", + "cabinet": null, + "pos": [ + 252775.2, + 274730.0 + ] + }, + { + "id": "FC0064", + "constant": "cInFC0064", + "hwAddress": "%E006.4", + "comment": "MSS ausgelöst FC0064 (CV-M1205)", + "role": "motorProtection", + "unit": "M1205", + "cabinet": null, + "pos": [ + 252775.2, + 274460.0 + ] + }, + { + "id": "FC0065", + "constant": "cInFC0065", + "hwAddress": "%E006.5", + "comment": "MSS ausgelöst FC0065 (CV-M1206)", + "role": "motorProtection", + "unit": "M1206", + "cabinet": null, + "pos": [ + 252775.2, + 274190.0 + ] + }, + { + "id": "FC0066", + "constant": "cInFC0066", + "hwAddress": "%E006.6", + "comment": "MSS ausgelöst FC0066 (CV-M1207)", + "role": "motorProtection", + "unit": "M1207", + "cabinet": null, + "pos": [ + 252775.2, + 273920.0 + ] + }, + { + "id": "FC0067", + "constant": "cInFC0067", + "hwAddress": "%E006.7", + "comment": "MSS ausgelöst FC0067 (CV-M1208)", + "role": "motorProtection", + "unit": "M1208", + "cabinet": null, + "pos": [ + 252775.2, + 273650.0 + ] + }, + { + "id": "FC0070", + "constant": "cInFC0070", + "hwAddress": "%E007.0", + "comment": "MSS ausgelöst FC0070 (CV-M1209)", + "role": "motorProtection", + "unit": "M1209", + "cabinet": null, + "pos": [ + 255437.7, + 275540.0 + ] + }, + { + "id": "FC0071", + "constant": "cInFC0071", + "hwAddress": "%E007.1", + "comment": "MSS ausgelöst FC0071 (CV-M1401)", + "role": "motorProtection", + "unit": "M1401", + "cabinet": null, + "pos": [ + 255437.7, + 275270.0 + ] + }, + { + "id": "FC0072", + "constant": "cInFC0072", + "hwAddress": "%E007.2", + "comment": "MSS ausgelöst FC0072 (CV-M1501)", + "role": "motorProtection", + "unit": "M1501", + "cabinet": null, + "pos": [ + 255437.7, + 275000.0 + ] + }, + { + "id": "FC0073", + "constant": "cInFC0073", + "hwAddress": "%E007.3", + "comment": "MSS ausgelöst FC0073 (CV-M1601)", + "role": "motorProtection", + "unit": "M1601", + "cabinet": null, + "pos": [ + 255447.1, + 274730.4 + ] + }, + { + "id": "FC0074", + "constant": "cInFC0074", + "hwAddress": "%E007.4", + "comment": "MSS ausgelöst FC0074 (CV-M4701)", + "role": "motorProtection", + "unit": "M4701", + "cabinet": null, + "pos": [ + 255437.7, + 274460.0 + ] + }, + { + "id": "FC0075", + "constant": "cInFC0075", + "hwAddress": "%E007.5", + "comment": "MSS ausgelöst FC0075 (KR-M1110)", + "role": "motorProtection", + "unit": "M1110", + "cabinet": null, + "pos": [ + 255437.7, + 274190.0 + ] + }, + { + "id": "FC0076", + "constant": "cInFC0076", + "hwAddress": "%E007.6", + "comment": "MSS ausgelöst FC0076 (CV-M1801)", + "role": "motorProtection", + "unit": "M1801", + "cabinet": null, + "pos": [ + 255437.7, + 273920.0 + ] + }, + { + "id": "FC0077", + "constant": "cInFC0077", + "hwAddress": "%E007.7", + "comment": "MSS ausgelöst FC0077 (CV-M1801)", + "role": "motorProtection", + "unit": "M1801", + "cabinet": null, + "pos": null + }, + { + "id": "SF0080", + "constant": "cInSF0080", + "hwAddress": "%E008.0", + "comment": "Bereichshalt UZ0209", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245550.4, + 301081.7 + ] + }, + { + "id": "SF0081", + "constant": "cInSF0081", + "hwAddress": "%E008.1", + "comment": "Reset UZ0209", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245550.4, + 300811.7 + ] + }, + { + "id": "SF0082", + "constant": "cInSF0082", + "hwAddress": "%E008.2", + "comment": "Bereichshalt UZ0210", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245500.3, + 283195.6 + ] + }, + { + "id": "SF0083", + "constant": "cInSF0083", + "hwAddress": "%E008.3", + "comment": "Reset UZ0210", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245500.3, + 282925.6 + ] + }, + { + "id": "SF0084", + "constant": "cInSF0084", + "hwAddress": "%E008.4", + "comment": "Bereichshalt UZ0211", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 250188.6, + 299336.1 + ] + }, + { + "id": "SF0085", + "constant": "cInSF0085", + "hwAddress": "%E008.5", + "comment": "Reset UZ0211", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 250188.6, + 299066.1 + ] + }, + { + "id": "DI0100", + "constant": "cInDI0100", + "hwAddress": "%E010.0", + "comment": "Meldekontakt 400V Motor+Bremse", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 310736.3 + ] + }, + { + "id": "DI0101", + "constant": "cInDI0101", + "hwAddress": "%E010.1", + "comment": "Vorsicherung 24V OK (FC101)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 310466.3 + ] + }, + { + "id": "DI0102", + "constant": "cInDI0102", + "hwAddress": "%E010.2", + "comment": "Vorsicherung 24V OK (FC102)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 310196.3 + ] + }, + { + "id": "DI0103", + "constant": "cInDI0103", + "hwAddress": "%E010.3", + "comment": "Vorsicherung 24V OK (FC103)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 309926.3 + ] + }, + { + "id": "DI0106", + "constant": "cInDI0106", + "hwAddress": "%E010.6", + "comment": "Feedback Hauptschütze aktiv (QA0920/QA0921)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 309240.9 + ] + }, + { + "id": "BP0107", + "constant": "cInBP0107", + "hwAddress": "%E010.7", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UC021", + "pos": [ + 247624.1, + 307156.1 + ] + }, + { + "id": "DI0114", + "constant": "cInDI0114", + "hwAddress": "%E011.4", + "comment": "Feedback Koppelrelais E-Stop-IF (QA0922/QA0923)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 308360.9 + ] + }, + { + "id": "SF0117", + "constant": "cInSF0117", + "hwAddress": "%E011.7", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 312826.8 + ] + }, + { + "id": "SF0120", + "constant": "cInSF0120", + "hwAddress": "%E012.0", + "comment": "Bereichshalt UZ2101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181277.4, + 310462.1 + ] + }, + { + "id": "SF0121", + "constant": "cInSF0121", + "hwAddress": "%E012.1", + "comment": "Reset UZ2101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181277.4, + 310192.1 + ] + }, + { + "id": "SF0122", + "constant": "cInSF0122", + "hwAddress": "%E012.2", + "comment": "Bereichshalt UZ2102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199419.1, + 310608.9 + ] + }, + { + "id": "SF0123", + "constant": "cInSF0123", + "hwAddress": "%E012.3", + "comment": "Reset UZ2102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199419.1, + 310338.9 + ] + }, + { + "id": "SF0124", + "constant": "cInSF0124", + "hwAddress": "%E012.4", + "comment": "Bereichshalt UZ2103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217828.3, + 311554.7 + ] + }, + { + "id": "SF0125", + "constant": "cInSF0125", + "hwAddress": "%E012.5", + "comment": "Reset UZ2103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217828.3, + 311284.7 + ] + }, + { + "id": "SF0126", + "constant": "cInSF0126", + "hwAddress": "%E012.6", + "comment": "Bereichshalt UZ2104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234665.5, + 310572.7 + ] + }, + { + "id": "SF0127", + "constant": "cInSF0127", + "hwAddress": "%E012.7", + "comment": "Reset UZ2104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234665.5, + 310302.7 + ] + }, + { + "id": "FC0140", + "constant": "cInFC0140", + "hwAddress": "%E014.0", + "comment": "MSS ausgelöst FC0140 (KR-M1101)", + "role": "motorProtection", + "unit": "M1101", + "cabinet": null, + "pos": [ + 252874.1, + 306685.8 + ] + }, + { + "id": "FC0141", + "constant": "cInFC0141", + "hwAddress": "%E014.1", + "comment": "MSS ausgelöst FC0141 (KR-M1102)", + "role": "motorProtection", + "unit": "M1102", + "cabinet": null, + "pos": [ + 252874.1, + 306415.8 + ] + }, + { + "id": "FC0142", + "constant": "cInFC0142", + "hwAddress": "%E014.2", + "comment": "MSS ausgelöst FC0142 (CV-M1105)", + "role": "motorProtection", + "unit": "M1105", + "cabinet": null, + "pos": [ + 252874.1, + 306145.8 + ] + }, + { + "id": "FC0143", + "constant": "cInFC0143", + "hwAddress": "%E014.3", + "comment": "MSS ausgelöst FC0143 (CV-M1106)", + "role": "motorProtection", + "unit": "M1106", + "cabinet": null, + "pos": [ + 252874.1, + 305875.8 + ] + }, + { + "id": "FC0144", + "constant": "cInFC0144", + "hwAddress": "%E014.4", + "comment": "MSS ausgelöst FC0144 (CV-M1107)", + "role": "motorProtection", + "unit": "M1107", + "cabinet": null, + "pos": [ + 254787.2, + 306685.8 + ] + }, + { + "id": "FC0145", + "constant": "cInFC0145", + "hwAddress": "%E014.5", + "comment": "MSS ausgelöst FC0145 (CV-M1108)", + "role": "motorProtection", + "unit": "M1108", + "cabinet": null, + "pos": [ + 254787.2, + 306415.8 + ] + }, + { + "id": "FC0146", + "constant": "cInFC0146", + "hwAddress": "%E014.6", + "comment": "MSS ausgelöst FC0146 (CV-M1109)", + "role": "motorProtection", + "unit": "M1109", + "cabinet": null, + "pos": [ + 254787.2, + 306145.8 + ] + }, + { + "id": "DI0160", + "constant": "cInDI0160", + "hwAddress": "%E016.0", + "comment": "Meldekontakt 400V Motor+Bremse", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 267389.7 + ] + }, + { + "id": "DI0161", + "constant": "cInDI0161", + "hwAddress": "%E016.1", + "comment": "Vorsicherung 24V OK (FC161)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 267119.7 + ] + }, + { + "id": "DI0162", + "constant": "cInDI0162", + "hwAddress": "%E016.2", + "comment": "Vorsicherung 24V OK (FC162)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 266849.7 + ] + }, + { + "id": "DI0163", + "constant": "cInDI0163", + "hwAddress": "%E016.3", + "comment": "Vorsicherung 24V OK (FC163)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 266579.7 + ] + }, + { + "id": "DI0164", + "constant": "cInDI0164", + "hwAddress": "%E016.4", + "comment": "Vorsicherung 24V OK (FC164)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 266309.7 + ] + }, + { + "id": "DI0165", + "constant": "cInDI0165", + "hwAddress": "%E016.5", + "comment": "Vorsicherung 24V OK (FC165)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 266039.7 + ] + }, + { + "id": "DI0166", + "constant": "cInDI0166", + "hwAddress": "%E016.6", + "comment": "Feedback Hauptschütze aktiv (QA1230/QA1231)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 265364.7 + ] + }, + { + "id": "BP0167", + "constant": "cInBP0167", + "hwAddress": "%E016.7", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UC022", + "pos": [ + 250872.2, + 269451.5 + ] + }, + { + "id": "DI0174", + "constant": "cInDI0174", + "hwAddress": "%E017.4", + "comment": "Feedback Koppelrelais E-Stop-IF (QA1232/QA1233)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 264495.2 + ] + }, + { + "id": "SF0177", + "constant": "cInSF0177", + "hwAddress": "%E017.7", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 269861.7 + ] + }, + { + "id": "SF0180", + "constant": "cInSF0180", + "hwAddress": "%E018.0", + "comment": "Bereichshalt UZ2201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180254.6, + 271108.8 + ] + }, + { + "id": "SF0181", + "constant": "cInSF0181", + "hwAddress": "%E018.1", + "comment": "Reset UZ2201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180258.1, + 270841.7 + ] + }, + { + "id": "SF0182", + "constant": "cInSF0182", + "hwAddress": "%E018.2", + "comment": "Bereichshalt UZ2202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 271091.5 + ] + }, + { + "id": "SF0183", + "constant": "cInSF0183", + "hwAddress": "%E018.3", + "comment": "Reset UZ2202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 270828.9 + ] + }, + { + "id": "SF0184", + "constant": "cInSF0184", + "hwAddress": "%E018.4", + "comment": "Bereichshalt UZ2203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 271316.7 + ] + }, + { + "id": "SF0185", + "constant": "cInSF0185", + "hwAddress": "%E018.5", + "comment": "Reset UZ2203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 271046.7 + ] + }, + { + "id": "SF0186", + "constant": "cInSF0186", + "hwAddress": "%E018.6", + "comment": "Bereichshalt UZ2204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234628.2, + 270827.6 + ] + }, + { + "id": "SF0187", + "constant": "cInSF0187", + "hwAddress": "%E018.7", + "comment": "Reset UZ2204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234628.2, + 270557.6 + ] + }, + { + "id": "SF0190", + "constant": "cInSF0190", + "hwAddress": "%E019.0", + "comment": "Bereichshalt UZ2205", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180258.1, + 268990.2 + ] + }, + { + "id": "SF0191", + "constant": "cInSF0191", + "hwAddress": "%E019.1", + "comment": "Reset UZ2205", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180258.1, + 268720.2 + ] + }, + { + "id": "SF0192", + "constant": "cInSF0192", + "hwAddress": "%E019.2", + "comment": "Bereichshalt UZ2206", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 268986.7 + ] + }, + { + "id": "SF0193", + "constant": "cInSF0193", + "hwAddress": "%E019.3", + "comment": "Reset UZ2206", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 268716.7 + ] + }, + { + "id": "SF0194", + "constant": "cInSF0194", + "hwAddress": "%E019.4", + "comment": "Bereichshalt UZ2207", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 268989.1 + ] + }, + { + "id": "SF0195", + "constant": "cInSF0195", + "hwAddress": "%E019.5", + "comment": "Reset UZ2207", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 268708.0 + ] + }, + { + "id": "SF0196", + "constant": "cInSF0196", + "hwAddress": "%E019.6", + "comment": "Bereichshalt UZ2208", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234637.1, + 268607.9 + ] + }, + { + "id": "SF0197", + "constant": "cInSF0197", + "hwAddress": "%E019.7", + "comment": "Reset UZ2208", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234637.1, + 268337.9 + ] + }, + { + "id": "FC0200", + "constant": "cInFC0200", + "hwAddress": "%E020.0", + "comment": "MSS ausgelöst FC0200 (KR-M1203)", + "role": "motorProtection", + "unit": "M1203", + "cabinet": null, + "pos": [ + 252669.5, + 262747.3 + ] + }, + { + "id": "FC0201", + "constant": "cInFC0201", + "hwAddress": "%E020.1", + "comment": "MSS ausgelöst FC0201 (KR-M1204)", + "role": "motorProtection", + "unit": "M1204", + "cabinet": null, + "pos": [ + 252669.5, + 262477.3 + ] + }, + { + "id": "FC0202", + "constant": "cInFC0202", + "hwAddress": "%E020.2", + "comment": "MSS ausgelöst FC0202 (KR-M1301)", + "role": "motorProtection", + "unit": "M1301", + "cabinet": null, + "pos": [ + 252669.5, + 262207.3 + ] + }, + { + "id": "FC0203", + "constant": "cInFC0203", + "hwAddress": "%E020.3", + "comment": "MSS ausgelöst FC0203 (KR-M1302)", + "role": "motorProtection", + "unit": "M1302", + "cabinet": null, + "pos": [ + 252669.5, + 261937.3 + ] + }, + { + "id": "DI0220", + "constant": "cInDI0220", + "hwAddress": "%E022.0", + "comment": "Meldekontakt 400V Motor+Bremse", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252980.0, + 252506.9 + ] + }, + { + "id": "DI0221", + "constant": "cInDI0221", + "hwAddress": "%E022.1", + "comment": "Vorsicherung 24V OK (FC221)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252980.0, + 252236.9 + ] + }, + { + "id": "DI0222", + "constant": "cInDI0222", + "hwAddress": "%E022.2", + "comment": "Vorsicherung 24V OK (FC222)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252980.0, + 251966.9 + ] + }, + { + "id": "DI0223", + "constant": "cInDI0223", + "hwAddress": "%E022.3", + "comment": "Vorsicherung 24V OK (FC223)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252980.0, + 251696.9 + ] + }, + { + "id": "DI0226", + "constant": "cInDI0226", + "hwAddress": "%E022.6", + "comment": "Feedback Hauptschütze aktiv (QA1540/QA1541)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252980.7, + 251019.3 + ] + }, + { + "id": "BP0227", + "constant": "cInBP0227", + "hwAddress": "%E022.7", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UC023", + "pos": [ + 245871.9, + 248229.8 + ] + }, + { + "id": "DI0234", + "constant": "cInDI0234", + "hwAddress": "%E023.4", + "comment": "Feedback Koppelrelais E-Stop-IF (QA1542/QA1531)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252995.9, + 250166.7 + ] + }, + { + "id": "SF0237", + "constant": "cInSF0237", + "hwAddress": "%E023.7", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252980.0, + 254417.4 + ] + }, + { + "id": "SF0240", + "constant": "cInSF0240", + "hwAddress": "%E024.0", + "comment": "Bereichshalt UZ2301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181403.6, + 247644.3 + ] + }, + { + "id": "SF0241", + "constant": "cInSF0241", + "hwAddress": "%E024.1", + "comment": "Reset UZ2301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181407.1, + 247377.2 + ] + }, + { + "id": "SF0242", + "constant": "cInSF0242", + "hwAddress": "%E024.2", + "comment": "Bereichshalt UZ2302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200236.7, + 247725.2 + ] + }, + { + "id": "SF0243", + "constant": "cInSF0243", + "hwAddress": "%E024.3", + "comment": "Reset UZ2302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200236.7, + 247455.2 + ] + }, + { + "id": "SF0244", + "constant": "cInSF0244", + "hwAddress": "%E024.4", + "comment": "Bereichshalt UZ2303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211226.6, + 247421.5 + ] + }, + { + "id": "SF0245", + "constant": "cInSF0245", + "hwAddress": "%E024.5", + "comment": "Reset UZ2303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211226.6, + 247151.5 + ] + }, + { + "id": "SF0246", + "constant": "cInSF0246", + "hwAddress": "%E024.6", + "comment": "Bereichshalt UZ2304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235072.7, + 247630.6 + ] + }, + { + "id": "SF0247", + "constant": "cInSF0247", + "hwAddress": "%E024.7", + "comment": "Reset UZ2304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235073.6, + 247355.2 + ] + }, + { + "id": "FC0260", + "constant": "cInFC0260", + "hwAddress": "%E026.0", + "comment": "MSS ausgelöst FC0260 (KR-M1303)", + "role": "motorProtection", + "unit": "M1303", + "cabinet": null, + "pos": [ + 252961.6, + 248448.5 + ] + }, + { + "id": "FC0261", + "constant": "cInFC0261", + "hwAddress": "%E026.1", + "comment": "MSS ausgelöst FC0261 (KR-M1304)", + "role": "motorProtection", + "unit": "M1304", + "cabinet": null, + "pos": [ + 252961.6, + 248178.5 + ] + }, + { + "id": "FC0262", + "constant": "cInFC0262", + "hwAddress": "%E026.2", + "comment": "MSS ausgelöst FC0262 (CV-M1305)", + "role": "motorProtection", + "unit": "M1305", + "cabinet": null, + "pos": [ + 252961.6, + 247901.5 + ] + }, + { + "id": "FC0263", + "constant": "cInFC0263", + "hwAddress": "%E026.3", + "comment": "MSS ausgelöst FC0263 (CV-M1306)", + "role": "motorProtection", + "unit": "M1306", + "cabinet": null, + "pos": [ + 252961.6, + 247635.1 + ] + }, + { + "id": "FC0264", + "constant": "cInFC0264", + "hwAddress": "%E026.4", + "comment": "MSS ausgelöst FC0264 (CV-M1307)", + "role": "motorProtection", + "unit": "M1307", + "cabinet": null, + "pos": [ + 252961.6, + 247365.1 + ] + }, + { + "id": "FC0265", + "constant": "cInFC0265", + "hwAddress": "%E026.5", + "comment": "MSS ausgelöst FC0265 (CV-M1308)", + "role": "motorProtection", + "unit": "M1308", + "cabinet": null, + "pos": [ + 252961.6, + 247095.1 + ] + }, + { + "id": "FC0266", + "constant": "cInFC0266", + "hwAddress": "%E026.6", + "comment": "MSS ausgelöst FC0266 (CV-M1309)", + "role": "motorProtection", + "unit": "M1309", + "cabinet": null, + "pos": [ + 252961.6, + 246825.1 + ] + }, + { + "id": "SF0400", + "constant": "cInSF0400", + "hwAddress": "%E040.0", + "comment": "Not Halt Kanal 1 UH02", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 286013.2 + ] + }, + { + "id": "SF0401", + "constant": "cInSF0401", + "hwAddress": "%E040.1", + "comment": "Not Halt Kanal 1 UZ0201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180258.1, + 290131.1 + ] + }, + { + "id": "SF0402", + "constant": "cInSF0402", + "hwAddress": "%E040.2", + "comment": "Not Halt Kanal 1 UZ0202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 195117.7, + 290222.5 + ] + }, + { + "id": "SF0403", + "constant": "cInSF0403", + "hwAddress": "%E040.3", + "comment": "Not Halt Kanal 1 UZ0203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212646.2, + 290226.3 + ] + }, + { + "id": "SF0404", + "constant": "cInSF0404", + "hwAddress": "%E040.4", + "comment": "Not Halt Kanal 2 UH02", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 285743.2 + ] + }, + { + "id": "SF0405", + "constant": "cInSF0405", + "hwAddress": "%E040.5", + "comment": "Not Halt Kanal 2 UZ0201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180258.1, + 289861.1 + ] + }, + { + "id": "SF0406", + "constant": "cInSF0406", + "hwAddress": "%E040.6", + "comment": "Not Halt Kanal 2 UZ0202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 195117.7, + 289952.5 + ] + }, + { + "id": "SF0407", + "constant": "cInSF0407", + "hwAddress": "%E040.7", + "comment": "Not Halt Kanal 2 UZ0203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212646.2, + 289956.3 + ] + }, + { + "id": "SF0470", + "constant": "cInSF0470", + "hwAddress": "%E047.0", + "comment": "Not Halt Kanal 1 UZ0204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 238287.3, + 289430.9 + ] + }, + { + "id": "SF0471", + "constant": "cInSF0471", + "hwAddress": "%E047.1", + "comment": "Not Halt Kanal 1 UZ0209", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245550.4, + 300511.5 + ] + }, + { + "id": "SF0472", + "constant": "cInSF0472", + "hwAddress": "%E047.2", + "comment": "Not Halt Kanal 1 UZ0210", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245504.5, + 282625.4 + ] + }, + { + "id": "SF0473", + "constant": "cInSF0473", + "hwAddress": "%E047.3", + "comment": "Not Halt Kanal 1 UZ0211", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 250188.6, + 298765.9 + ] + }, + { + "id": "SF0474", + "constant": "cInSF0474", + "hwAddress": "%E047.4", + "comment": "Not Halt Kanal 2 UZ0204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 238287.3, + 289160.9 + ] + }, + { + "id": "SF0475", + "constant": "cInSF0475", + "hwAddress": "%E047.5", + "comment": "Not Halt Kanal 2 UZ0209", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245550.4, + 300241.5 + ] + }, + { + "id": "SF0476", + "constant": "cInSF0476", + "hwAddress": "%E047.6", + "comment": "Not Halt Kanal 2 UZ0210", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245504.5, + 282355.4 + ] + }, + { + "id": "SF0477", + "constant": "cInSF0477", + "hwAddress": "%E047.7", + "comment": "Not Halt Kanal 2 UZ0211", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 250188.6, + 298495.9 + ] + }, + { + "id": "SF0541", + "constant": "cInSF0541", + "hwAddress": "%E054.1", + "comment": "Not Halt Schnittstelle CH1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 278060.1 + ] + }, + { + "id": "SF0542", + "constant": "cInSF0542", + "hwAddress": "%E054.2", + "comment": "Not Halt Schnittstelle von UH05 CH1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 277790.1 + ] + }, + { + "id": "SF0545", + "constant": "cInSF0545", + "hwAddress": "%E054.5", + "comment": "Not Halt Schnittstelle von UH03 CH2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 276566.5 + ] + }, + { + "id": "SF0546", + "constant": "cInSF0546", + "hwAddress": "%E054.6", + "comment": "Not Halt Schnittstelle von UH05 CH2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 276296.5 + ] + }, + { + "id": "SF0710", + "constant": "cInSF0710", + "hwAddress": "%E071.0", + "comment": "Not Halt Kanal 1 UC021", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 311746.8 + ] + }, + { + "id": "SF0711", + "constant": "cInSF0711", + "hwAddress": "%E071.1", + "comment": "Not Halt Kanal 1 UZ2101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181277.4, + 309901.8 + ] + }, + { + "id": "SF0712", + "constant": "cInSF0712", + "hwAddress": "%E071.2", + "comment": "Not Halt Kanal 1 UZ2102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199419.1, + 310048.9 + ] + }, + { + "id": "SF0713", + "constant": "cInSF0713", + "hwAddress": "%E071.3", + "comment": "Not Halt Kanal 1 UZ2103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217827.4, + 310994.7 + ] + }, + { + "id": "SF0714", + "constant": "cInSF0714", + "hwAddress": "%E071.4", + "comment": "Not Halt Kanal 2 UC021", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 311476.8 + ] + }, + { + "id": "SF0715", + "constant": "cInSF0715", + "hwAddress": "%E071.5", + "comment": "Not Halt Kanal 2 UZ2101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181277.4, + 309631.8 + ] + }, + { + "id": "SF0716", + "constant": "cInSF0716", + "hwAddress": "%E071.6", + "comment": "Not Halt Kanal 2 UZ2102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199419.1, + 309778.9 + ] + }, + { + "id": "SF0717", + "constant": "cInSF0717", + "hwAddress": "%E071.7", + "comment": "Not Halt Kanal 2 UZ2103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217827.4, + 310724.7 + ] + }, + { + "id": "SF0780", + "constant": "cInSF0780", + "hwAddress": "%E078.0", + "comment": "Not Halt Kanal 1 UZ2104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234665.5, + 310002.5 + ] + }, + { + "id": "SF0781", + "constant": "cInSF0781", + "hwAddress": "%E078.1", + "comment": "Not Halt Schnittstelle CH1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 307781.1 + ] + }, + { + "id": "SF0784", + "constant": "cInSF0784", + "hwAddress": "%E078.4", + "comment": "Not Halt Kanal 2 UZ2104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234665.5, + 309732.5 + ] + }, + { + "id": "SF0785", + "constant": "cInSF0785", + "hwAddress": "%E078.5", + "comment": "Not Halt Schnittstelle CH2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 307511.1 + ] + }, + { + "id": "SF1020", + "constant": "cInSF1020", + "hwAddress": "%E102.0", + "comment": "Not Halt Kanal 1 UC022", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 268489.8 + ] + }, + { + "id": "SF1021", + "constant": "cInSF1021", + "hwAddress": "%E102.1", + "comment": "Not Halt Kanal 1 UZ2201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180258.1, + 270551.7 + ] + }, + { + "id": "SF1022", + "constant": "cInSF1022", + "hwAddress": "%E102.2", + "comment": "Not Halt Kanal 1 UZ2202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 270531.5 + ] + }, + { + "id": "SF1023", + "constant": "cInSF1023", + "hwAddress": "%E102.3", + "comment": "Not Halt Kanal 1 UZ2203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 270756.7 + ] + }, + { + "id": "SF1024", + "constant": "cInSF1024", + "hwAddress": "%E102.4", + "comment": "Not Halt Kanal 2 UC022", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 268219.8 + ] + }, + { + "id": "SF1025", + "constant": "cInSF1025", + "hwAddress": "%E102.5", + "comment": "Not Halt Kanal 2 UZ2201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180258.1, + 270281.7 + ] + }, + { + "id": "SF1026", + "constant": "cInSF1026", + "hwAddress": "%E102.6", + "comment": "Not Halt Kanal 2 UZ2202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 270261.5 + ] + }, + { + "id": "SF1027", + "constant": "cInSF1027", + "hwAddress": "%E102.7", + "comment": "Not Halt Kanal 2 UZ2203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 270486.7 + ] + }, + { + "id": "SF1090", + "constant": "cInSF1090", + "hwAddress": "%E109.0", + "comment": "Not Halt Kanal 1 UZ2204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234628.2, + 270159.3 + ] + }, + { + "id": "SF1091", + "constant": "cInSF1091", + "hwAddress": "%E109.1", + "comment": "Not Halt Schnittstelle CH1 (UC073-UC022)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 263894.7 + ] + }, + { + "id": "SF1094", + "constant": "cInSF1094", + "hwAddress": "%E109.4", + "comment": "Not Halt Kanal 2 UZ2204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234628.2, + 269889.3 + ] + }, + { + "id": "SF1095", + "constant": "cInSF1095", + "hwAddress": "%E109.5", + "comment": "Not Halt Schnittstelle CH2 (UC073-UC022)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252687.9, + 263624.7 + ] + }, + { + "id": "SF1330", + "constant": "cInSF1330", + "hwAddress": "%E133.0", + "comment": "Not Halt Kanal 1 UC023", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252980.0, + 253315.5 + ] + }, + { + "id": "SF1331", + "constant": "cInSF1331", + "hwAddress": "%E133.1", + "comment": "Not Halt Kanal 1 UZ2301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181407.1, + 247087.2 + ] + }, + { + "id": "SF1332", + "constant": "cInSF1332", + "hwAddress": "%E133.2", + "comment": "Not Halt Kanal 1 UZ2302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200236.7, + 247165.2 + ] + }, + { + "id": "SF1333", + "constant": "cInSF1333", + "hwAddress": "%E133.3", + "comment": "Not Halt Kanal 1 UZ2303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211226.6, + 246827.7 + ] + }, + { + "id": "SF1334", + "constant": "cInSF1334", + "hwAddress": "%E133.4", + "comment": "Not Halt Kanal 2 UC023", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252980.0, + 253045.5 + ] + }, + { + "id": "SF1335", + "constant": "cInSF1335", + "hwAddress": "%E133.5", + "comment": "Not Halt Kanal 2 UZ2301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181407.1, + 246817.2 + ] + }, + { + "id": "SF1336", + "constant": "cInSF1336", + "hwAddress": "%E133.6", + "comment": "Not Halt Kanal 2 UZ2302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200236.7, + 246895.2 + ] + }, + { + "id": "SF1337", + "constant": "cInSF1337", + "hwAddress": "%E133.7", + "comment": "Not Halt Kanal 2 UZ2303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211226.6, + 246557.7 + ] + }, + { + "id": "SF1400", + "constant": "cInSF1400", + "hwAddress": "%E140.0", + "comment": "Not Halt Kanal 1 UZ2304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235073.6, + 247065.2 + ] + }, + { + "id": "SF1401", + "constant": "cInSF1401", + "hwAddress": "%E140.1", + "comment": "Not Halt Schnittstelle CH1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252980.0, + 249581.9 + ] + }, + { + "id": "SF1404", + "constant": "cInSF1404", + "hwAddress": "%E140.4", + "comment": "Not Halt Kanal 2 UZ2304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235073.6, + 246795.2 + ] + }, + { + "id": "SF1405", + "constant": "cInSF1405", + "hwAddress": "%E140.5", + "comment": "Not Halt Schnittstelle CH2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252980.0, + 249311.9 + ] + }, + { + "id": "BG3000", + "constant": "cInBG3000", + "hwAddress": "%E300.0", + "comment": "in Separator 2 (ILS-CV M1105)", + "role": "sensorInSep", + "unit": "M1105", + "cabinet": "UC2101", + "pos": [ + 187132.0, + 307871.7 + ] + }, + { + "id": "BG3001", + "constant": "cInBG3001", + "hwAddress": "%E300.1", + "comment": "Pin Abfrage (KR-M1101 ) Block 1.1.1", + "role": "sensorPinQuery", + "unit": "M1101", + "cabinet": "UC2101", + "pos": [ + 187137.4, + 308835.0 + ] + }, + { + "id": "BG3002", + "constant": "cInBG3002", + "hwAddress": "%E300.2", + "comment": "Prüfung MT Pos.1 (KR-K1101 Einfahrt Block 1.1.1)", + "role": "sensorPinQuery", + "unit": "K1101", + "cabinet": "UC2101", + "pos": [ + 186658.6, + 309134.2 + ] + }, + { + "id": "BG3003", + "constant": "cInBG3003", + "hwAddress": "%E300.3", + "comment": "Stausensor (KR-M1101 Block 1.1.2)", + "role": "sensorJam", + "unit": "M1101", + "cabinet": "UC2101", + "pos": [ + 187941.8, + 308835.0 + ] + }, + { + "id": "BG3004", + "constant": "cInBG3004", + "hwAddress": "%E300.4", + "comment": "in Separator 1 (ILS-CV M1105)", + "role": "sensorInSep", + "unit": "M1105", + "cabinet": "UC2101", + "pos": [ + 187127.8, + 307279.5 + ] + }, + { + "id": "BG3005", + "constant": "cInBG3005", + "hwAddress": "%E300.5", + "comment": "Stausensor Str.1 (CV-M1105 vor BT-Beladung)", + "role": "sensorJam", + "unit": "M1105", + "cabinet": "UC2101", + "pos": [ + 187126.0, + 306968.4 + ] + }, + { + "id": "BG3006", + "constant": "cInBG3006", + "hwAddress": "%E300.6", + "comment": "Sensor Förderer voll (ILS-CV M1105)", + "role": "sensorConvFull", + "unit": "M1105", + "cabinet": "UC2101", + "pos": [ + 187126.0, + 306346.4 + ] + }, + { + "id": "BG3007", + "constant": "cInBG3007", + "hwAddress": "%E300.7", + "comment": "Prüfung MT Pos.2 (KR-K1101 Einfahrt Block 1.1.1)", + "role": "sensorPinQuery", + "unit": "K1101", + "cabinet": "UC2101", + "pos": [ + 183191.4, + 309127.8 + ] + }, + { + "id": "BG3010", + "constant": "cInBG3010", + "hwAddress": "%E301.0", + "comment": "Prüfung MT Pos.3 (KR-K1101 Einfahrt Block 1.1.1)", + "role": "sensorPinQuery", + "unit": "K1101", + "cabinet": "UC2101", + "pos": [ + 178799.9, + 309122.4 + ] + }, + { + "id": "BG3011", + "constant": "cInBG3011", + "hwAddress": "%E301.1", + "comment": "Prüfung MT Pos.4 (KR-K1101 Einfahrt Block 1.1.1)", + "role": "sensorPinQuery", + "unit": "K1101", + "cabinet": "UC2101", + "pos": [ + 175587.3, + 309122.4 + ] + }, + { + "id": "BG3012", + "constant": "cInBG3012", + "hwAddress": "%E301.2", + "comment": "Prüfung MT Pos.5 (KR-K1101 Einfahrt Block 1.1.1)", + "role": "sensorPinQuery", + "unit": "K1101", + "cabinet": "UC2101", + "pos": [ + 172113.1, + 309122.4 + ] + }, + { + "id": "BG3030", + "constant": "cInBG3030", + "hwAddress": "%E303.0", + "comment": "Stausensor Str.1 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 185950.3, + 307695.7 + ] + }, + { + "id": "BG3031", + "constant": "cInBG3031", + "hwAddress": "%E303.1", + "comment": "Stausensor Str.2 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 185150.0, + 307822.3 + ] + }, + { + "id": "BG3032", + "constant": "cInBG3032", + "hwAddress": "%E303.2", + "comment": "Stausensor Str.3 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 184349.9, + 307822.3 + ] + }, + { + "id": "BG3033", + "constant": "cInBG3033", + "hwAddress": "%E303.3", + "comment": "Stausensor Str.4 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 183550.0, + 307822.0 + ] + }, + { + "id": "BG3034", + "constant": "cInBG3034", + "hwAddress": "%E303.4", + "comment": "Stausensor Str.5 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 182749.9, + 307822.3 + ] + }, + { + "id": "BG3035", + "constant": "cInBG3035", + "hwAddress": "%E303.5", + "comment": "Stausensor Str.6 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 181949.9, + 307822.3 + ] + }, + { + "id": "BG3036", + "constant": "cInBG3036", + "hwAddress": "%E303.6", + "comment": "Stausensor Str.7 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 181150.0, + 307822.0 + ] + }, + { + "id": "BG3037", + "constant": "cInBG3037", + "hwAddress": "%E303.7", + "comment": "Stausensor Str.8 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 179149.9, + 307822.3 + ] + }, + { + "id": "BG3040", + "constant": "cInBG3040", + "hwAddress": "%E304.0", + "comment": "Stausensor Str.9 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 178349.9, + 307822.3 + ] + }, + { + "id": "BG3041", + "constant": "cInBG3041", + "hwAddress": "%E304.1", + "comment": "Stausensor Str.10 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 177550.0, + 307822.0 + ] + }, + { + "id": "BG3042", + "constant": "cInBG3042", + "hwAddress": "%E304.2", + "comment": "Stausensor Str.11 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 176749.9, + 307822.3 + ] + }, + { + "id": "BG3043", + "constant": "cInBG3043", + "hwAddress": "%E304.3", + "comment": "Stausensor Str.12 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 175949.9, + 307822.3 + ] + }, + { + "id": "BG3044", + "constant": "cInBG3044", + "hwAddress": "%E304.4", + "comment": "Stausensor Str.13 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 175150.0, + 307822.0 + ] + }, + { + "id": "BG3045", + "constant": "cInBG3045", + "hwAddress": "%E304.5", + "comment": "Stausensor Str.14 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 174000.0, + 307822.3 + ] + }, + { + "id": "BG3046", + "constant": "cInBG3046", + "hwAddress": "%E304.6", + "comment": "Stausensor Str.15 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 173200.0, + 307822.3 + ] + }, + { + "id": "BG3047", + "constant": "cInBG3047", + "hwAddress": "%E304.7", + "comment": "Stausensor Str.16 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 172400.1, + 307822.0 + ] + }, + { + "id": "BG3050", + "constant": "cInBG3050", + "hwAddress": "%E305.0", + "comment": "Stausensor Str.17 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 171600.0, + 307822.3 + ] + }, + { + "id": "BG3051", + "constant": "cInBG3051", + "hwAddress": "%E305.1", + "comment": "Stausensor Str.18 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 170800.0, + 307822.3 + ] + }, + { + "id": "BG3052", + "constant": "cInBG3052", + "hwAddress": "%E305.2", + "comment": "Stausensor Str.19 (Block 1.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2101", + "pos": [ + 170000.1, + 307822.0 + ] + }, + { + "id": "BG3060", + "constant": "cInBG3060", + "hwAddress": "%E306.0", + "comment": "in Separator 2 (ILS-CV M1106)", + "role": "sensorInSep", + "unit": "M1106", + "cabinet": "UC2102", + "pos": [ + 204368.7, + 307871.7 + ] + }, + { + "id": "BG3061", + "constant": "cInBG3061", + "hwAddress": "%E306.1", + "comment": "Pin Abfrage (KR-M1101 ) Block 1.1.2", + "role": "sensorPinQuery", + "unit": "M1101", + "cabinet": "UC2102", + "pos": [ + 204081.7, + 308835.0 + ] + }, + { + "id": "BG3062", + "constant": "cInBG3062", + "hwAddress": "%E306.2", + "comment": "Prüfung MT Pos.1 (KR-K1101 Einfahrt Block 1.1.2)", + "role": "sensorPinQuery", + "unit": "K1101", + "cabinet": "UC2102", + "pos": [ + 203729.6, + 309134.2 + ] + }, + { + "id": "BG3063", + "constant": "cInBG3063", + "hwAddress": "%E306.3", + "comment": "Stausensor Str.2 (KR-M1101)", + "role": "sensorJam", + "unit": "M1101", + "cabinet": "UC2102", + "pos": [ + 204281.0, + 309470.4 + ] + }, + { + "id": "BG3064", + "constant": "cInBG3064", + "hwAddress": "%E306.4", + "comment": "in Separator 1 (ILS-CV M1106)", + "role": "sensorInSep", + "unit": "M1106", + "cabinet": "UC2102", + "pos": [ + 204364.4, + 307279.5 + ] + }, + { + "id": "BG3065", + "constant": "cInBG3065", + "hwAddress": "%E306.5", + "comment": "Stausensor Str.1 (KR-K1101 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K1101", + "cabinet": "UC2102", + "pos": [ + 204362.7, + 306968.4 + ] + }, + { + "id": "BG3066", + "constant": "cInBG3066", + "hwAddress": "%E306.6", + "comment": "Sensor Förderer voll (ILS-CV M1106)", + "role": "sensorConvFull", + "unit": "M1106", + "cabinet": "UC2102", + "pos": [ + 204356.5, + 306333.1 + ] + }, + { + "id": "BG3067", + "constant": "cInBG3067", + "hwAddress": "%E306.7", + "comment": "Prüfung MT Pos.2 (KR-K1101 Einfahrt Block 1.1.2)", + "role": "sensorPinQuery", + "unit": "K1101", + "cabinet": "UC2102", + "pos": [ + 200294.7, + 309122.4 + ] + }, + { + "id": "BG3070", + "constant": "cInBG3070", + "hwAddress": "%E307.0", + "comment": "Prüfung MT Pos.3 (KR-K1101 Einfahrt Block 1.1.2)", + "role": "sensorPinQuery", + "unit": "K1101", + "cabinet": "UC2102", + "pos": [ + 196641.7, + 309124.6 + ] + }, + { + "id": "BG3071", + "constant": "cInBG3071", + "hwAddress": "%E307.1", + "comment": "Prüfung MT Pos.4 (KR-K1101 Einfahrt Block 1.1.2)", + "role": "sensorPinQuery", + "unit": "K1101", + "cabinet": "UC2102", + "pos": [ + 193555.9, + 309122.4 + ] + }, + { + "id": "BG3072", + "constant": "cInBG3072", + "hwAddress": "%E307.2", + "comment": "Prüfung MT Pos.5 (KR-K1101 Einfahrt Block 1.1.2)", + "role": "sensorPinQuery", + "unit": "K1101", + "cabinet": "UC2102", + "pos": [ + 189533.1, + 309122.4 + ] + }, + { + "id": "BG3073", + "constant": "cInBG3073", + "hwAddress": "%E307.3", + "comment": "Stausensor MT vor Pinband (KR-M1101 Block 1.1.2)", + "role": "sensorJam", + "unit": "M1101", + "cabinet": "UC2102", + "pos": [ + 188790.6, + 309122.4 + ] + }, + { + "id": "BG3090", + "constant": "cInBG3090", + "hwAddress": "%E309.0", + "comment": "Stausensor Str.1 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 203150.0, + 307695.7 + ] + }, + { + "id": "BG3091", + "constant": "cInBG3091", + "hwAddress": "%E309.1", + "comment": "Stausensor Str.2 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 202350.0, + 307822.4 + ] + }, + { + "id": "BG3092", + "constant": "cInBG3092", + "hwAddress": "%E309.2", + "comment": "Stausensor Str.3 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 201550.0, + 307822.4 + ] + }, + { + "id": "BG3093", + "constant": "cInBG3093", + "hwAddress": "%E309.3", + "comment": "Stausensor Str.4 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 200750.1, + 307822.1 + ] + }, + { + "id": "BG3094", + "constant": "cInBG3094", + "hwAddress": "%E309.4", + "comment": "Stausensor Str.5 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 199950.0, + 307822.4 + ] + }, + { + "id": "BG3095", + "constant": "cInBG3095", + "hwAddress": "%E309.5", + "comment": "Stausensor Str.6 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 199150.0, + 307822.4 + ] + }, + { + "id": "BG3096", + "constant": "cInBG3096", + "hwAddress": "%E309.6", + "comment": "Stausensor Str.7 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 197950.0, + 307822.4 + ] + }, + { + "id": "BG3097", + "constant": "cInBG3097", + "hwAddress": "%E309.7", + "comment": "Stausensor Str.8 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 197100.2, + 307822.4 + ] + }, + { + "id": "BG3100", + "constant": "cInBG3100", + "hwAddress": "%E310.0", + "comment": "Stausensor Str.9 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 196300.1, + 307822.3 + ] + }, + { + "id": "BG3101", + "constant": "cInBG3101", + "hwAddress": "%E310.1", + "comment": "Stausensor Str.10 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 195500.2, + 307822.0 + ] + }, + { + "id": "BG3102", + "constant": "cInBG3102", + "hwAddress": "%E310.2", + "comment": "Stausensor Str.11 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 194700.1, + 307822.3 + ] + }, + { + "id": "BG3103", + "constant": "cInBG3103", + "hwAddress": "%E310.3", + "comment": "Stausensor Str.12 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 193900.1, + 307822.3 + ] + }, + { + "id": "BG3104", + "constant": "cInBG3104", + "hwAddress": "%E310.4", + "comment": "Stausensor Str.13 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 193100.2, + 307822.0 + ] + }, + { + "id": "BG3105", + "constant": "cInBG3105", + "hwAddress": "%E310.5", + "comment": "Stausensor Str.14 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 191300.0, + 307822.3 + ] + }, + { + "id": "BG3106", + "constant": "cInBG3106", + "hwAddress": "%E310.6", + "comment": "Stausensor Str.15 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 190500.0, + 307822.3 + ] + }, + { + "id": "BG3107", + "constant": "cInBG3107", + "hwAddress": "%E310.7", + "comment": "Stausensor Str.16 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 189700.1, + 307822.0 + ] + }, + { + "id": "BG3110", + "constant": "cInBG3110", + "hwAddress": "%E311.0", + "comment": "Stausensor Str.17 (Block 1.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2102", + "pos": [ + 188900.0, + 307822.3 + ] + }, + { + "id": "BG3120", + "constant": "cInBG3120", + "hwAddress": "%E312.0", + "comment": "in Separator 2 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 207427.8, + 307734.6 + ] + }, + { + "id": "BG3121", + "constant": "cInBG3121", + "hwAddress": "%E312.1", + "comment": "Pin Abfrage (KR-M1102 ) Block 1.1.3", + "role": "sensorPinQuery", + "unit": "M1102", + "cabinet": "UC2103", + "pos": [ + 207166.3, + 308839.1 + ] + }, + { + "id": "BG3122", + "constant": "cInBG3122", + "hwAddress": "%E312.2", + "comment": "Prüfung MT Pos.1 (KR-K1102 Einfahrt Block 1.1.3)", + "role": "sensorPinQuery", + "unit": "K1102", + "cabinet": "UC2103", + "pos": [ + 207628.8, + 309134.2 + ] + }, + { + "id": "BG3123", + "constant": "cInBG3123", + "hwAddress": "%E312.3", + "comment": "Stausensor Str.2 (KR-M1102)", + "role": "sensorJam", + "unit": "M1102", + "cabinet": "UC2103", + "pos": [ + 206622.0, + 308127.3 + ] + }, + { + "id": "BG3124", + "constant": "cInBG3124", + "hwAddress": "%E312.4", + "comment": "in Separator 1 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 206614.4, + 307169.4 + ] + }, + { + "id": "BG3125", + "constant": "cInBG3125", + "hwAddress": "%E312.5", + "comment": "Stausensor Str.1 (KR-K1102 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K1102", + "cabinet": "UC2103", + "pos": [ + 206612.7, + 306858.2 + ] + }, + { + "id": "BG3126", + "constant": "cInBG3126", + "hwAddress": "%E312.6", + "comment": "Sensor Förderer voll (ILS-CV 1106)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 206612.7, + 306253.0 + ] + }, + { + "id": "BG3127", + "constant": "cInBG3127", + "hwAddress": "%E312.7", + "comment": "Prüfung MT Pos.2 (KR-K1102 Einfahrt Block 1.1.3)", + "role": "sensorPinQuery", + "unit": "K1102", + "cabinet": "UC2103", + "pos": [ + 211110.0, + 309122.4 + ] + }, + { + "id": "BG3130", + "constant": "cInBG3130", + "hwAddress": "%E313.0", + "comment": "Prüfung MT Pos.3 (KR-K1102 Einfahrt Block 1.1.3)", + "role": "sensorPinQuery", + "unit": "K1102", + "cabinet": "UC2103", + "pos": [ + 214297.6, + 309122.4 + ] + }, + { + "id": "BG3131", + "constant": "cInBG3131", + "hwAddress": "%E313.1", + "comment": "Prüfung MT Pos.4 (KR-K1102 Einfahrt Block 1.1.3)", + "role": "sensorPinQuery", + "unit": "K1102", + "cabinet": "UC2103", + "pos": [ + 218467.0, + 309122.4 + ] + }, + { + "id": "BG3132", + "constant": "cInBG3132", + "hwAddress": "%E313.2", + "comment": "Prüfung MT Pos.5 (KR-K1102 Einfahrt Block 1.1.3)", + "role": "sensorPinQuery", + "unit": "K1102", + "cabinet": "UC2103", + "pos": [ + 221678.7, + 309122.4 + ] + }, + { + "id": "BG3133", + "constant": "cInBG3133", + "hwAddress": "%E313.3", + "comment": "Prüfung MT Pos.6 (KR-K1102 Einfahrt Block 1.1.3)", + "role": "sensorPinQuery", + "unit": "K1102", + "cabinet": "UC2103", + "pos": [ + 225265.9, + 309122.4 + ] + }, + { + "id": "BG3134", + "constant": "cInBG3134", + "hwAddress": "%E313.4", + "comment": "in Separator 3 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 212479.5, + 310541.6 + ] + }, + { + "id": "BG3135", + "constant": "cInBG3135", + "hwAddress": "%E313.5", + "comment": "Stausensor 1 (M1109)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 213222.0, + 310541.6 + ] + }, + { + "id": "BG3136", + "constant": "cInBG3136", + "hwAddress": "%E313.6", + "comment": "Sensor Förderer voll (ILS-CV M1109)", + "role": "sensorConvFull", + "unit": "M1109", + "cabinet": "UC2103", + "pos": [ + 214754.0, + 310822.2 + ] + }, + { + "id": "BG3137", + "constant": "cInBG3137", + "hwAddress": "%E313.7", + "comment": "in Separator 4 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 207135.3, + 309810.7 + ] + }, + { + "id": "BG3141", + "constant": "cInBG3141", + "hwAddress": "%E314.1", + "comment": "Stausensor 2 (KR-M1102)", + "role": "sensorJam", + "unit": "M1102", + "cabinet": "UC2103", + "pos": [ + 210664.8, + 309586.4 + ] + }, + { + "id": "BG3142", + "constant": "cInBG3142", + "hwAddress": "%E314.2", + "comment": "Stausensor MT vor Pinband (KR-M1102 Block 1.1.3)", + "role": "sensorJam", + "unit": "M1102", + "cabinet": "UC2103", + "pos": [ + 226360.6, + 308836.2 + ] + }, + { + "id": "BG3143", + "constant": "cInBG3143", + "hwAddress": "%E314.3", + "comment": "in Separator (ILS-CV M1109)", + "role": "sensorInSep", + "unit": "M1109", + "cabinet": "UC2103", + "pos": [ + 222435.2, + 460903.2 + ] + }, + { + "id": "BG3144", + "constant": "cInBG3144", + "hwAddress": "%E314.4", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1109)", + "role": "sensorFinger", + "unit": "M1109", + "cabinet": "UC2103", + "pos": [ + 221695.4, + 460906.6 + ] + }, + { + "id": "BG3145", + "constant": "cInBG3145", + "hwAddress": "%E314.5", + "comment": "MT in Position (ILS-CV M1109)", + "role": "sensorCarrInPos", + "unit": "M1109", + "cabinet": "UC2103", + "pos": [ + 220950.2, + 460903.2 + ] + }, + { + "id": "BG3150", + "constant": "cInBG3150", + "hwAddress": "%E315.0", + "comment": "Stausensor Str.1 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 208400.0, + 307808.0 + ] + }, + { + "id": "BG3151", + "constant": "cInBG3151", + "hwAddress": "%E315.1", + "comment": "Stausensor Str.2 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 209200.0, + 307807.9 + ] + }, + { + "id": "BG3152", + "constant": "cInBG3152", + "hwAddress": "%E315.2", + "comment": "Stausensor Str.3 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 210000.0, + 307807.9 + ] + }, + { + "id": "BG3153", + "constant": "cInBG3153", + "hwAddress": "%E315.3", + "comment": "Stausensor Str.4 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 211146.1, + 307807.8 + ] + }, + { + "id": "BG3154", + "constant": "cInBG3154", + "hwAddress": "%E315.4", + "comment": "Stausensor Str.5 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 211946.1, + 307807.8 + ] + }, + { + "id": "BG3155", + "constant": "cInBG3155", + "hwAddress": "%E315.5", + "comment": "Stausensor Str.6 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 212746.1, + 307807.9 + ] + }, + { + "id": "BG3156", + "constant": "cInBG3156", + "hwAddress": "%E315.6", + "comment": "Stausensor Str.7 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 213545.3, + 307807.8 + ] + }, + { + "id": "BG3157", + "constant": "cInBG3157", + "hwAddress": "%E315.7", + "comment": "Stausensor Str.8 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 214346.1, + 307807.8 + ] + }, + { + "id": "BG3160", + "constant": "cInBG3160", + "hwAddress": "%E316.0", + "comment": "Stausensor Str.9 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 215146.1, + 307808.6 + ] + }, + { + "id": "BG3161", + "constant": "cInBG3161", + "hwAddress": "%E316.1", + "comment": "Stausensor Str.10 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 217150.0, + 307807.7 + ] + }, + { + "id": "BG3162", + "constant": "cInBG3162", + "hwAddress": "%E316.2", + "comment": "Stausensor Str.11 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 217950.0, + 307807.7 + ] + }, + { + "id": "BG3163", + "constant": "cInBG3163", + "hwAddress": "%E316.3", + "comment": "Stausensor Str.12 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 218750.0, + 307807.6 + ] + }, + { + "id": "BG3164", + "constant": "cInBG3164", + "hwAddress": "%E316.4", + "comment": "Stausensor Str.13 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 219549.1, + 307807.6 + ] + }, + { + "id": "BG3165", + "constant": "cInBG3165", + "hwAddress": "%E316.5", + "comment": "Stausensor Str.14 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 220350.0, + 307807.6 + ] + }, + { + "id": "BG3166", + "constant": "cInBG3166", + "hwAddress": "%E316.6", + "comment": "Stausensor Str.15 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 221150.0, + 307807.7 + ] + }, + { + "id": "BG3167", + "constant": "cInBG3167", + "hwAddress": "%E316.7", + "comment": "Stausensor Str.16 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 221950.0, + 307807.6 + ] + }, + { + "id": "BG3170", + "constant": "cInBG3170", + "hwAddress": "%E317.0", + "comment": "Stausensor Str.17 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 223150.0, + 307807.6 + ] + }, + { + "id": "BG3171", + "constant": "cInBG3171", + "hwAddress": "%E317.1", + "comment": "Stausensor Str.18 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 223950.0, + 307807.7 + ] + }, + { + "id": "BG3172", + "constant": "cInBG3172", + "hwAddress": "%E317.2", + "comment": "Stausensor Str.19 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 224748.4, + 307807.6 + ] + }, + { + "id": "BG3173", + "constant": "cInBG3173", + "hwAddress": "%E317.3", + "comment": "Stausensor Str.20 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 225550.0, + 307807.7 + ] + }, + { + "id": "BG3174", + "constant": "cInBG3174", + "hwAddress": "%E317.4", + "comment": "Stausensor Str.21 (Block 1.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2103", + "pos": [ + 226350.0, + 307807.7 + ] + }, + { + "id": "BG3180", + "constant": "cInBG3180", + "hwAddress": "%E318.0", + "comment": "in Separator 2 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 227619.3, + 307857.7 + ] + }, + { + "id": "BG3181", + "constant": "cInBG3181", + "hwAddress": "%E318.1", + "comment": "Pin Abfrage (KR-M1102 ) Block 1.1.4", + "role": "sensorPinQuery", + "unit": "M1102", + "cabinet": "UC2104", + "pos": [ + 227916.3, + 308837.5 + ] + }, + { + "id": "BG3182", + "constant": "cInBG3182", + "hwAddress": "%E318.2", + "comment": "Prüfung MT Pos.1 (KR-K1102 Einfahrt Block 1.1.4)", + "role": "sensorPinQuery", + "unit": "K1102", + "cabinet": "UC2104", + "pos": [ + 228219.5, + 309133.9 + ] + }, + { + "id": "BG3183", + "constant": "cInBG3183", + "hwAddress": "%E318.3", + "comment": "Stausensor Str.2 (M1102)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 227156.9, + 308839.5 + ] + }, + { + "id": "BG3184", + "constant": "cInBG3184", + "hwAddress": "%E318.4", + "comment": "in Separator 1 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 227614.4, + 307275.6 + ] + }, + { + "id": "BG3185", + "constant": "cInBG3185", + "hwAddress": "%E318.5", + "comment": "Stausensor Str.1 (KR-K1102 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K1102", + "cabinet": "UC2104", + "pos": [ + 227612.7, + 306964.4 + ] + }, + { + "id": "BG3186", + "constant": "cInBG3186", + "hwAddress": "%E318.6", + "comment": "Sensor Förderer voll (ILS-CV 1102)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 227611.3, + 306312.8 + ] + }, + { + "id": "BG3187", + "constant": "cInBG3187", + "hwAddress": "%E318.7", + "comment": "Prüfung MT Pos.2 (KR-K1102 Einfahrt Block 1.1.4)", + "role": "sensorPinQuery", + "unit": "K1102", + "cabinet": "UC2104", + "pos": [ + 231576.6, + 309136.8 + ] + }, + { + "id": "BG3190", + "constant": "cInBG3190", + "hwAddress": "%E319.0", + "comment": "Prüfung MT Pos.3 (KR-K1102 Einfahrt Block 1.1.4)", + "role": "sensorPinQuery", + "unit": "K1102", + "cabinet": "UC2104", + "pos": [ + 234839.3, + 309122.4 + ] + }, + { + "id": "BG3191", + "constant": "cInBG3191", + "hwAddress": "%E319.1", + "comment": "Prüfung MT Pos.4 (KR-K1102 Einfahrt Block 1.1.4)", + "role": "sensorPinQuery", + "unit": "K1102", + "cabinet": "UC2104", + "pos": [ + 238060.0, + 309126.0 + ] + }, + { + "id": "BG3210", + "constant": "cInBG3210", + "hwAddress": "%E321.0", + "comment": "Stausensor Str.1 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 229150.0, + 307808.0 + ] + }, + { + "id": "BG3211", + "constant": "cInBG3211", + "hwAddress": "%E321.1", + "comment": "Stausensor Str.2 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 229950.0, + 307807.9 + ] + }, + { + "id": "BG3212", + "constant": "cInBG3212", + "hwAddress": "%E321.2", + "comment": "Stausensor Str.3 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 230750.0, + 307807.9 + ] + }, + { + "id": "BG3213", + "constant": "cInBG3213", + "hwAddress": "%E321.3", + "comment": "Stausensor Str.4 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 231550.0, + 307807.8 + ] + }, + { + "id": "BG3214", + "constant": "cInBG3214", + "hwAddress": "%E321.4", + "comment": "Stausensor Str.5 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 232350.0, + 307807.8 + ] + }, + { + "id": "BG3215", + "constant": "cInBG3215", + "hwAddress": "%E321.5", + "comment": "Stausensor Str.6 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 233150.0, + 307807.9 + ] + }, + { + "id": "BG3216", + "constant": "cInBG3216", + "hwAddress": "%E321.6", + "comment": "Stausensor Str.7 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 233949.1, + 307807.8 + ] + }, + { + "id": "BG3217", + "constant": "cInBG3217", + "hwAddress": "%E321.7", + "comment": "Stausensor Str.8 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 235150.0, + 307808.6 + ] + }, + { + "id": "BG3220", + "constant": "cInBG3220", + "hwAddress": "%E322.0", + "comment": "Stausensor Str.9 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 235950.0, + 307808.6 + ] + }, + { + "id": "BG3221", + "constant": "cInBG3221", + "hwAddress": "%E322.1", + "comment": "Stausensor Str.10 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 236750.0, + 307807.7 + ] + }, + { + "id": "BG3222", + "constant": "cInBG3222", + "hwAddress": "%E322.2", + "comment": "Stausensor Str.11 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 237550.0, + 307807.7 + ] + }, + { + "id": "BG3223", + "constant": "cInBG3223", + "hwAddress": "%E322.3", + "comment": "Stausensor Str.12 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 238350.0, + 307807.6 + ] + }, + { + "id": "BG3224", + "constant": "cInBG3224", + "hwAddress": "%E322.4", + "comment": "Stausensor Str.13 (Block 1.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2104", + "pos": [ + 239149.1, + 307807.6 + ] + }, + { + "id": "BG3240", + "constant": "cInBG3240", + "hwAddress": "%E324.0", + "comment": "in Separator 1 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 186664.6, + 291059.5 + ] + }, + { + "id": "BG3241", + "constant": "cInBG3241", + "hwAddress": "%E324.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1105)", + "role": "sensorJam", + "unit": "M1105", + "cabinet": "UC0201", + "pos": [ + 187300.2, + 292318.2 + ] + }, + { + "id": "BG3242", + "constant": "cInBG3242", + "hwAddress": "%E324.2", + "comment": "Stausensor 1 (KR-M1103 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1103", + "cabinet": "UC0201", + "pos": [ + 186431.0, + 292042.8 + ] + }, + { + "id": "BG3243", + "constant": "cInBG3243", + "hwAddress": "%E324.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1105)", + "role": "sensorFinger", + "unit": "M1105", + "cabinet": "UC0201", + "pos": [ + 187302.9, + 293168.9 + ] + }, + { + "id": "BG3244", + "constant": "cInBG3244", + "hwAddress": "%E324.4", + "comment": "in Separator 2 (ILS-CV M1105)", + "role": "sensorInSep", + "unit": "M1105", + "cabinet": "UC0201", + "pos": [ + 187300.2, + 292602.5 + ] + }, + { + "id": "BG3245", + "constant": "cInBG3245", + "hwAddress": "%E324.5", + "comment": "in Separator (KR-M1103)", + "role": "sensorInSep", + "unit": "M1103", + "cabinet": "UC0201", + "pos": [ + 170687.9, + 290371.6 + ] + }, + { + "id": "BG3247", + "constant": "cInBG3247", + "hwAddress": "%E324.7", + "comment": "MT in Position (ILS-CV M1105)", + "role": "sensorCarrInPos", + "unit": "M1105", + "cabinet": "UC0201", + "pos": [ + 187300.2, + 293435.5 + ] + }, + { + "id": "BG3270", + "constant": "cInBG3270", + "hwAddress": "%E327.0", + "comment": "in Separator 1 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 185950.0, + 292667.6 + ] + }, + { + "id": "BG3271", + "constant": "cInBG3271", + "hwAddress": "%E327.1", + "comment": "in Separator 2 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 185150.0, + 292667.6 + ] + }, + { + "id": "BG3272", + "constant": "cInBG3272", + "hwAddress": "%E327.2", + "comment": "in Separator 3 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 184350.0, + 292667.6 + ] + }, + { + "id": "BG3273", + "constant": "cInBG3273", + "hwAddress": "%E327.3", + "comment": "in Separator 4 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 183550.0, + 292667.6 + ] + }, + { + "id": "BG3274", + "constant": "cInBG3274", + "hwAddress": "%E327.4", + "comment": "in Separator 5 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 182750.0, + 292667.6 + ] + }, + { + "id": "BG3275", + "constant": "cInBG3275", + "hwAddress": "%E327.5", + "comment": "in Separator 6 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 181950.0, + 292667.6 + ] + }, + { + "id": "BG3276", + "constant": "cInBG3276", + "hwAddress": "%E327.6", + "comment": "in Separator 7 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 181150.0, + 292667.6 + ] + }, + { + "id": "BG3277", + "constant": "cInBG3277", + "hwAddress": "%E327.7", + "comment": "in Separator 8 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 179149.9, + 292667.6 + ] + }, + { + "id": "BG3280", + "constant": "cInBG3280", + "hwAddress": "%E328.0", + "comment": "in Separator 9 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 178349.9, + 292667.6 + ] + }, + { + "id": "BG3281", + "constant": "cInBG3281", + "hwAddress": "%E328.1", + "comment": "in Separator 10 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 177549.9, + 292667.6 + ] + }, + { + "id": "BG3282", + "constant": "cInBG3282", + "hwAddress": "%E328.2", + "comment": "in Separator 11 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 176749.9, + 292667.6 + ] + }, + { + "id": "BG3283", + "constant": "cInBG3283", + "hwAddress": "%E328.3", + "comment": "in Separator 12 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 175949.9, + 292667.6 + ] + }, + { + "id": "BG3284", + "constant": "cInBG3284", + "hwAddress": "%E328.4", + "comment": "in Separator 13 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 175149.9, + 292667.6 + ] + }, + { + "id": "BG3285", + "constant": "cInBG3285", + "hwAddress": "%E328.5", + "comment": "in Separator 14 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 174000.0, + 292667.5 + ] + }, + { + "id": "BG3286", + "constant": "cInBG3286", + "hwAddress": "%E328.6", + "comment": "in Separator 15 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 173200.0, + 292667.5 + ] + }, + { + "id": "BG3287", + "constant": "cInBG3287", + "hwAddress": "%E328.7", + "comment": "in Separator 16 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 172400.0, + 292667.5 + ] + }, + { + "id": "BG3290", + "constant": "cInBG3290", + "hwAddress": "%E329.0", + "comment": "in Separator 17 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 171600.0, + 292667.5 + ] + }, + { + "id": "BG3291", + "constant": "cInBG3291", + "hwAddress": "%E329.1", + "comment": "in Separator 18 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 170800.0, + 292667.5 + ] + }, + { + "id": "BG3292", + "constant": "cInBG3292", + "hwAddress": "%E329.2", + "comment": "In Separator 19 (Block 1.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0201", + "pos": [ + 170000.0, + 292667.5 + ] + }, + { + "id": "BG3300", + "constant": "cInBG3300", + "hwAddress": "%E330.0", + "comment": "in Separator 1 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 203430.1, + 291083.0 + ] + }, + { + "id": "BG3301", + "constant": "cInBG3301", + "hwAddress": "%E330.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1106 Block 1.1.2)", + "role": "sensorJam", + "unit": "M1106", + "cabinet": "UC0202", + "pos": [ + 204500.2, + 292318.1 + ] + }, + { + "id": "BG3302", + "constant": "cInBG3302", + "hwAddress": "%E330.2", + "comment": "Stausensor 1 (KR-M1103 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1103", + "cabinet": "UC0202", + "pos": [ + 203631.0, + 292042.7 + ] + }, + { + "id": "BG3303", + "constant": "cInBG3303", + "hwAddress": "%E330.3", + "comment": "Abfrage Mitnehmerfinger in Position (Block 1.1.2)", + "role": "sensorFinger", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 204502.9, + 293172.8 + ] + }, + { + "id": "BG3304", + "constant": "cInBG3304", + "hwAddress": "%E330.4", + "comment": "in Separator 2 (ILS-CV M1106 Block 1.1.2)", + "role": "sensorInSep", + "unit": "M1106", + "cabinet": "UC0202", + "pos": [ + 204500.2, + 292607.9 + ] + }, + { + "id": "BG3305", + "constant": "cInBG3305", + "hwAddress": "%E330.5", + "comment": "Stausensor 3 (KR-M1103)", + "role": "sensorJam", + "unit": "M1103", + "cabinet": "UC0202", + "pos": [ + 203478.5, + 290598.8 + ] + }, + { + "id": "BG3306", + "constant": "cInBG3306", + "hwAddress": "%E330.6", + "comment": "Rad dreht (KR-M1103)", + "role": "sensorWheel", + "unit": "M1103", + "cabinet": "UC0202", + "pos": [ + 204250.9, + 290592.6 + ] + }, + { + "id": "BG3307", + "constant": "cInBG3307", + "hwAddress": "%E330.7", + "comment": "MT in Position (ILS-CV M1106)", + "role": "sensorCarrInPos", + "unit": "M1106", + "cabinet": "UC0202", + "pos": [ + 204500.2, + 293439.4 + ] + }, + { + "id": "BG3330", + "constant": "cInBG3330", + "hwAddress": "%E333.0", + "comment": "in Separator 1 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 203150.0, + 292667.6 + ] + }, + { + "id": "BG3331", + "constant": "cInBG3331", + "hwAddress": "%E333.1", + "comment": "in Separator 2 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 202350.0, + 292667.6 + ] + }, + { + "id": "BG3332", + "constant": "cInBG3332", + "hwAddress": "%E333.2", + "comment": "in Separator 3 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 201550.0, + 292667.6 + ] + }, + { + "id": "BG3333", + "constant": "cInBG3333", + "hwAddress": "%E333.3", + "comment": "in Separator 4 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 200750.0, + 292667.6 + ] + }, + { + "id": "BG3334", + "constant": "cInBG3334", + "hwAddress": "%E333.4", + "comment": "in Separator 5 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 199950.0, + 292667.6 + ] + }, + { + "id": "BG3335", + "constant": "cInBG3335", + "hwAddress": "%E333.5", + "comment": "in Separator 6 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 199150.0, + 292667.6 + ] + }, + { + "id": "BG3336", + "constant": "cInBG3336", + "hwAddress": "%E333.6", + "comment": "in Separator 7 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 197950.0, + 292667.6 + ] + }, + { + "id": "BG3337", + "constant": "cInBG3337", + "hwAddress": "%E333.7", + "comment": "in Separator 8 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 197100.0, + 292667.6 + ] + }, + { + "id": "BG3340", + "constant": "cInBG3340", + "hwAddress": "%E334.0", + "comment": "in Separator 9 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 196300.0, + 292667.6 + ] + }, + { + "id": "BG3341", + "constant": "cInBG3341", + "hwAddress": "%E334.1", + "comment": "in Separator 10 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 195500.0, + 292667.6 + ] + }, + { + "id": "BG3342", + "constant": "cInBG3342", + "hwAddress": "%E334.2", + "comment": "in Separator 11 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 194700.0, + 292667.6 + ] + }, + { + "id": "BG3343", + "constant": "cInBG3343", + "hwAddress": "%E334.3", + "comment": "in Separator 12 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 193900.0, + 292667.6 + ] + }, + { + "id": "BG3344", + "constant": "cInBG3344", + "hwAddress": "%E334.4", + "comment": "in Separator 13 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 193100.0, + 292667.6 + ] + }, + { + "id": "BG3345", + "constant": "cInBG3345", + "hwAddress": "%E334.5", + "comment": "in Separator 14 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 191300.0, + 292667.6 + ] + }, + { + "id": "BG3346", + "constant": "cInBG3346", + "hwAddress": "%E334.6", + "comment": "in Separator 15 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 190500.0, + 292667.6 + ] + }, + { + "id": "BG3347", + "constant": "cInBG3347", + "hwAddress": "%E334.7", + "comment": "in Separator 16 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 189700.0, + 292667.6 + ] + }, + { + "id": "BG3350", + "constant": "cInBG3350", + "hwAddress": "%E335.0", + "comment": "in Separator 17 (Block 1.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 188900.0, + 292667.6 + ] + }, + { + "id": "BG3360", + "constant": "cInBG3360", + "hwAddress": "%E336.0", + "comment": "in Separator 1 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 207893.0, + 291191.5 + ] + }, + { + "id": "BG3361", + "constant": "cInBG3361", + "hwAddress": "%E336.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1107)", + "role": "sensorJam", + "unit": "M1107", + "cabinet": "UC0203", + "pos": [ + 206540.2, + 292318.1 + ] + }, + { + "id": "BG3362", + "constant": "cInBG3362", + "hwAddress": "%E336.2", + "comment": "Stausensor 1 (KR-M1104 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1104", + "cabinet": "UC0203", + "pos": [ + 207431.0, + 292042.7 + ] + }, + { + "id": "BG3363", + "constant": "cInBG3363", + "hwAddress": "%E336.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1107)", + "role": "sensorFinger", + "unit": "M1107", + "cabinet": "UC0203", + "pos": [ + 206542.9, + 293172.8 + ] + }, + { + "id": "BG3364", + "constant": "cInBG3364", + "hwAddress": "%E336.4", + "comment": "in Separator 2 (ILS-CV M1107)", + "role": "sensorInSep", + "unit": "M1107", + "cabinet": "UC0203", + "pos": [ + 206540.2, + 292607.9 + ] + }, + { + "id": "BG3365", + "constant": "cInBG3365", + "hwAddress": "%E336.5", + "comment": "Stausensor (ILS-KR-M1104)", + "role": "sensorJam", + "unit": "M1104", + "cabinet": "UC0203", + "pos": [ + 206828.4, + 290580.6 + ] + }, + { + "id": "BG3367", + "constant": "cInBG3367", + "hwAddress": "%E336.7", + "comment": "MT in Position (ILS-CV M1107)", + "role": "sensorCarrInPos", + "unit": "M1107", + "cabinet": "UC0203", + "pos": [ + 206540.2, + 293439.4 + ] + }, + { + "id": "BG3390", + "constant": "cInBG3390", + "hwAddress": "%E339.0", + "comment": "in Separator 1 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 208400.0, + 292667.6 + ] + }, + { + "id": "BG3391", + "constant": "cInBG3391", + "hwAddress": "%E339.1", + "comment": "in Separator 2 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 209200.0, + 292667.6 + ] + }, + { + "id": "BG3392", + "constant": "cInBG3392", + "hwAddress": "%E339.2", + "comment": "in Separator 3 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 210000.0, + 292667.6 + ] + }, + { + "id": "BG3393", + "constant": "cInBG3393", + "hwAddress": "%E339.3", + "comment": "in Separator 4 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 211150.0, + 292667.6 + ] + }, + { + "id": "BG3394", + "constant": "cInBG3394", + "hwAddress": "%E339.4", + "comment": "in Separator 5 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 211950.0, + 292667.6 + ] + }, + { + "id": "BG3395", + "constant": "cInBG3395", + "hwAddress": "%E339.5", + "comment": "in Separator 6 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 212750.0, + 292667.6 + ] + }, + { + "id": "BG3396", + "constant": "cInBG3396", + "hwAddress": "%E339.6", + "comment": "in Separator 7 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 213550.0, + 292667.6 + ] + }, + { + "id": "BG3397", + "constant": "cInBG3397", + "hwAddress": "%E339.7", + "comment": "in Separator 8 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 214350.0, + 292667.6 + ] + }, + { + "id": "BG3400", + "constant": "cInBG3400", + "hwAddress": "%E340.0", + "comment": "in Separator 9 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 215150.0, + 292667.6 + ] + }, + { + "id": "BG3401", + "constant": "cInBG3401", + "hwAddress": "%E340.1", + "comment": "in Separator 10 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 217150.0, + 292667.6 + ] + }, + { + "id": "BG3402", + "constant": "cInBG3402", + "hwAddress": "%E340.2", + "comment": "in Separator 11 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 217950.0, + 292667.6 + ] + }, + { + "id": "BG3403", + "constant": "cInBG3403", + "hwAddress": "%E340.3", + "comment": "in Separator 12 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 218750.0, + 292667.6 + ] + }, + { + "id": "BG3404", + "constant": "cInBG3404", + "hwAddress": "%E340.4", + "comment": "in Separator 13 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 219550.0, + 292667.6 + ] + }, + { + "id": "BG3405", + "constant": "cInBG3405", + "hwAddress": "%E340.5", + "comment": "in Separator 14 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 220350.0, + 292667.6 + ] + }, + { + "id": "BG3406", + "constant": "cInBG3406", + "hwAddress": "%E340.6", + "comment": "in Separator 15 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 221150.0, + 292667.6 + ] + }, + { + "id": "BG3407", + "constant": "cInBG3407", + "hwAddress": "%E340.7", + "comment": "in Separator 16 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 221950.0, + 292667.6 + ] + }, + { + "id": "BG3410", + "constant": "cInBG3410", + "hwAddress": "%E341.0", + "comment": "in Separator 17 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 223150.0, + 292667.6 + ] + }, + { + "id": "BG3411", + "constant": "cInBG3411", + "hwAddress": "%E341.1", + "comment": "in Separator 18 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 223950.0, + 292667.6 + ] + }, + { + "id": "BG3412", + "constant": "cInBG3412", + "hwAddress": "%E341.2", + "comment": "in Separator 19 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 224750.0, + 292667.6 + ] + }, + { + "id": "BG3413", + "constant": "cInBG3413", + "hwAddress": "%E341.3", + "comment": "in Separator 20 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 225550.0, + 292667.6 + ] + }, + { + "id": "BG3414", + "constant": "cInBG3414", + "hwAddress": "%E341.4", + "comment": "in Separator 21 (Block 1.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 226350.0, + 292667.6 + ] + }, + { + "id": "BG3420", + "constant": "cInBG3420", + "hwAddress": "%E342.0", + "comment": "in Separator 1 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 228310.7, + 291208.2 + ] + }, + { + "id": "BG3421", + "constant": "cInBG3421", + "hwAddress": "%E342.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1108)", + "role": "sensorJam", + "unit": "M1108", + "cabinet": "UC0204", + "pos": [ + 227501.9, + 292318.2 + ] + }, + { + "id": "BG3422", + "constant": "cInBG3422", + "hwAddress": "%E342.2", + "comment": "Stausensor 1 (KR-M1104 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1104", + "cabinet": "UC0204", + "pos": [ + 228273.8, + 292042.8 + ] + }, + { + "id": "BG3423", + "constant": "cInBG3423", + "hwAddress": "%E342.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1108)", + "role": "sensorFinger", + "unit": "M1108", + "cabinet": "UC0204", + "pos": [ + 227504.6, + 293165.1 + ] + }, + { + "id": "BG3424", + "constant": "cInBG3424", + "hwAddress": "%E342.4", + "comment": "in Separator 2 (ILS-CV M1108)", + "role": "sensorInSep", + "unit": "M1108", + "cabinet": "UC0204", + "pos": [ + 227501.9, + 292615.3 + ] + }, + { + "id": "BG3425", + "constant": "cInBG3425", + "hwAddress": "%E342.5", + "comment": "in Separator 3 (ILS-CV M1104)", + "role": "sensorInSep", + "unit": "M1104", + "cabinet": "UC0204", + "pos": [ + 227170.7, + 290142.1 + ] + }, + { + "id": "BG3426", + "constant": "cInBG3426", + "hwAddress": "%E342.6", + "comment": "Stausensor 3 (KR-M1104)", + "role": "sensorJam", + "unit": "M1104", + "cabinet": "UC0204", + "pos": [ + 239527.4, + 292032.2 + ] + }, + { + "id": "BG3427", + "constant": "cInBG3427", + "hwAddress": "%E342.7", + "comment": "MT in Position (ILS-CV M1108)", + "role": "sensorCarrInPos", + "unit": "M1108", + "cabinet": "UC0204", + "pos": [ + 227501.9, + 293431.6 + ] + }, + { + "id": "BG3431", + "constant": "cInBG3431", + "hwAddress": "%E343.1", + "comment": "Stausensor 1 (M2109)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 228521.8, + 290102.3 + ] + }, + { + "id": "BG3433", + "constant": "cInBG3433", + "hwAddress": "%E343.3", + "comment": "Rad dreht (KR-M1104)", + "role": "sensorWheel", + "unit": "M1104", + "cabinet": "UC0204", + "pos": [ + 238482.8, + 291491.5 + ] + }, + { + "id": "BG3450", + "constant": "cInBG3450", + "hwAddress": "%E345.0", + "comment": "in Separator 1 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 229150.0, + 292667.6 + ] + }, + { + "id": "BG3451", + "constant": "cInBG3451", + "hwAddress": "%E345.1", + "comment": "in Separator 2 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 229950.0, + 292667.6 + ] + }, + { + "id": "BG3452", + "constant": "cInBG3452", + "hwAddress": "%E345.2", + "comment": "in Separator 3 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 230750.0, + 292667.6 + ] + }, + { + "id": "BG3453", + "constant": "cInBG3453", + "hwAddress": "%E345.3", + "comment": "in Separator 4 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 231550.0, + 292667.6 + ] + }, + { + "id": "BG3454", + "constant": "cInBG3454", + "hwAddress": "%E345.4", + "comment": "in Separator 5 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 232350.0, + 292667.6 + ] + }, + { + "id": "BG3455", + "constant": "cInBG3455", + "hwAddress": "%E345.5", + "comment": "in Separator 6 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 233150.0, + 292667.6 + ] + }, + { + "id": "BG3456", + "constant": "cInBG3456", + "hwAddress": "%E345.6", + "comment": "in Separator 7 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 233950.0, + 292667.6 + ] + }, + { + "id": "BG3457", + "constant": "cInBG3457", + "hwAddress": "%E345.7", + "comment": "in Separator 8 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 235150.0, + 292667.6 + ] + }, + { + "id": "BG3460", + "constant": "cInBG3460", + "hwAddress": "%E346.0", + "comment": "in Separator 9 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 235950.0, + 292667.6 + ] + }, + { + "id": "BG3461", + "constant": "cInBG3461", + "hwAddress": "%E346.1", + "comment": "in Separator 10 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 236750.0, + 292667.6 + ] + }, + { + "id": "BG3462", + "constant": "cInBG3462", + "hwAddress": "%E346.2", + "comment": "in Separator 11 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 237550.0, + 292667.6 + ] + }, + { + "id": "BG3463", + "constant": "cInBG3463", + "hwAddress": "%E346.3", + "comment": "in Separator 12 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 238350.0, + 292667.6 + ] + }, + { + "id": "BG3464", + "constant": "cInBG3464", + "hwAddress": "%E346.4", + "comment": "in Separator 13 (Block 1.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0204", + "pos": [ + 239150.0, + 292667.6 + ] + }, + { + "id": "BG3480", + "constant": "cInBG3480", + "hwAddress": "%E348.0", + "comment": "in Separator 2 (ILS-CV M1205)", + "role": "sensorInSep", + "unit": "M1205", + "cabinet": "UC0205", + "pos": [ + 187132.0, + 286871.7 + ] + }, + { + "id": "BG3481", + "constant": "cInBG3481", + "hwAddress": "%E348.1", + "comment": "Pin Abfrage (KR-M1201 ) Block 1.2.1", + "role": "sensorPinQuery", + "unit": "M1201", + "cabinet": "UC0205", + "pos": [ + 186977.5, + 287835.0 + ] + }, + { + "id": "BG3482", + "constant": "cInBG3482", + "hwAddress": "%E348.2", + "comment": "Prüfung MT Pos.1 (KR-K1201 Einfahrt Block 1.2.1)", + "role": "sensorPinQuery", + "unit": "K1201", + "cabinet": "UC0205", + "pos": [ + 186578.7, + 288134.2 + ] + }, + { + "id": "BG3483", + "constant": "cInBG3483", + "hwAddress": "%E348.3", + "comment": "Stausensor (KR-M1201)", + "role": "sensorJam", + "unit": "M1201", + "cabinet": "UC0205", + "pos": [ + 187781.9, + 287835.0 + ] + }, + { + "id": "BG3484", + "constant": "cInBG3484", + "hwAddress": "%E348.4", + "comment": "in Separator 1 (ILS-CV M1205)", + "role": "sensorInSep", + "unit": "M1205", + "cabinet": "UC0205", + "pos": [ + 187127.8, + 286279.5 + ] + }, + { + "id": "BG3485", + "constant": "cInBG3485", + "hwAddress": "%E348.5", + "comment": "Stausensor Str.1 (ILS-CV M1205)", + "role": "sensorJam", + "unit": "M1205", + "cabinet": "UC0205", + "pos": [ + 187126.0, + 285968.4 + ] + }, + { + "id": "BG3486", + "constant": "cInBG3486", + "hwAddress": "%E348.6", + "comment": "Sensor Förderer voll (ILS-CV M1205)", + "role": "sensorConvFull", + "unit": "M1205", + "cabinet": "UC0205", + "pos": [ + 187126.0, + 285390.4 + ] + }, + { + "id": "BG3487", + "constant": "cInBG3487", + "hwAddress": "%E348.7", + "comment": "Prüfung MT Pos.2 (KR-K1201 Einfahrt Block 1.2.1)", + "role": "sensorPinQuery", + "unit": "K1201", + "cabinet": "UC0205", + "pos": [ + 183192.3, + 288127.8 + ] + }, + { + "id": "BG3490", + "constant": "cInBG3490", + "hwAddress": "%E349.0", + "comment": "Prüfung MT Pos.3 (KR-K1201 Einfahrt Block 1.2.1)", + "role": "sensorPinQuery", + "unit": "K1201", + "cabinet": "UC0205", + "pos": [ + 178779.0, + 288122.4 + ] + }, + { + "id": "BG3491", + "constant": "cInBG3491", + "hwAddress": "%E349.1", + "comment": "Prüfung MT Pos.4 (KR-K1201 Einfahrt Block 1.2.1)", + "role": "sensorPinQuery", + "unit": "K1201", + "cabinet": "UC0205", + "pos": [ + 175605.8, + 288122.4 + ] + }, + { + "id": "BG3492", + "constant": "cInBG3492", + "hwAddress": "%E349.2", + "comment": "Prüfung MT Pos.5 (KR-K1201 Einfahrt Block 1.2.1)", + "role": "sensorPinQuery", + "unit": "K1201", + "cabinet": "UC0205", + "pos": [ + 172109.4, + 288122.4 + ] + }, + { + "id": "BG3510", + "constant": "cInBG3510", + "hwAddress": "%E351.0", + "comment": "Stausensor Str.1 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 185950.0, + 286695.7 + ] + }, + { + "id": "BG3511", + "constant": "cInBG3511", + "hwAddress": "%E351.1", + "comment": "Stausensor Str.2 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 185150.0, + 286822.3 + ] + }, + { + "id": "BG3512", + "constant": "cInBG3512", + "hwAddress": "%E351.2", + "comment": "Stausensor Str.3 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 184349.9, + 286822.3 + ] + }, + { + "id": "BG3513", + "constant": "cInBG3513", + "hwAddress": "%E351.3", + "comment": "Stausensor Str.4 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 183550.0, + 286822.0 + ] + }, + { + "id": "BG3514", + "constant": "cInBG3514", + "hwAddress": "%E351.4", + "comment": "Stausensor Str.5 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 182749.9, + 286822.3 + ] + }, + { + "id": "BG3515", + "constant": "cInBG3515", + "hwAddress": "%E351.5", + "comment": "Stausensor Str.6 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 181949.9, + 286822.3 + ] + }, + { + "id": "BG3516", + "constant": "cInBG3516", + "hwAddress": "%E351.6", + "comment": "Stausensor Str.7 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 181150.0, + 286822.0 + ] + }, + { + "id": "BG3517", + "constant": "cInBG3517", + "hwAddress": "%E351.7", + "comment": "Stausensor Str.8 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 179149.9, + 286822.2 + ] + }, + { + "id": "BG3520", + "constant": "cInBG3520", + "hwAddress": "%E352.0", + "comment": "Stausensor Str.9 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 178349.9, + 286822.2 + ] + }, + { + "id": "BG3521", + "constant": "cInBG3521", + "hwAddress": "%E352.1", + "comment": "Stausensor Str.10 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 177550.0, + 286821.9 + ] + }, + { + "id": "BG3522", + "constant": "cInBG3522", + "hwAddress": "%E352.2", + "comment": "Stausensor Str.11 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 176749.9, + 286822.2 + ] + }, + { + "id": "BG3523", + "constant": "cInBG3523", + "hwAddress": "%E352.3", + "comment": "Stausensor Str.12 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 175949.9, + 286822.3 + ] + }, + { + "id": "BG3524", + "constant": "cInBG3524", + "hwAddress": "%E352.4", + "comment": "Stausensor Str.13 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 175150.0, + 286822.0 + ] + }, + { + "id": "BG3525", + "constant": "cInBG3525", + "hwAddress": "%E352.5", + "comment": "Stausensor Str.14 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 174000.0, + 286822.3 + ] + }, + { + "id": "BG3526", + "constant": "cInBG3526", + "hwAddress": "%E352.6", + "comment": "Stausensor Str.15 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 173200.0, + 286822.3 + ] + }, + { + "id": "BG3527", + "constant": "cInBG3527", + "hwAddress": "%E352.7", + "comment": "Stausensor Str.16 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 172400.1, + 286822.0 + ] + }, + { + "id": "BG3530", + "constant": "cInBG3530", + "hwAddress": "%E353.0", + "comment": "Stausensor Str.17 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 171600.0, + 286822.3 + ] + }, + { + "id": "BG3531", + "constant": "cInBG3531", + "hwAddress": "%E353.1", + "comment": "Stausensor Str.18 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 170800.0, + 286822.3 + ] + }, + { + "id": "BG3532", + "constant": "cInBG3532", + "hwAddress": "%E353.2", + "comment": "Stausensor Str.19 (Block 1.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0205", + "pos": [ + 170000.1, + 286822.0 + ] + }, + { + "id": "BG3540", + "constant": "cInBG3540", + "hwAddress": "%E354.0", + "comment": "in Separator 2 (ILS-CV M1206)", + "role": "sensorInSep", + "unit": "M1206", + "cabinet": "UC0206", + "pos": [ + 204368.7, + 286871.7 + ] + }, + { + "id": "BG3541", + "constant": "cInBG3541", + "hwAddress": "%E354.1", + "comment": "Pin Abfrage (KR-M1201 ) Block 1.2.2", + "role": "sensorPinQuery", + "unit": "M1201", + "cabinet": "UC0206", + "pos": [ + 204081.7, + 287835.0 + ] + }, + { + "id": "BG3542", + "constant": "cInBG3542", + "hwAddress": "%E354.2", + "comment": "Prüfung MT Pos.1 (KR-K1201 Einfahrt Block 1.2.2)", + "role": "sensorPinQuery", + "unit": "K1201", + "cabinet": "UC0206", + "pos": [ + 203729.6, + 288134.2 + ] + }, + { + "id": "BG3543", + "constant": "cInBG3543", + "hwAddress": "%E354.3", + "comment": "Stausensor Str.2 (KR-M1201)", + "role": "sensorJam", + "unit": "M1201", + "cabinet": "UC0206", + "pos": [ + 204203.3, + 288467.7 + ] + }, + { + "id": "BG3544", + "constant": "cInBG3544", + "hwAddress": "%E354.4", + "comment": "in Separator 1 (ILS-CV M1206)", + "role": "sensorInSep", + "unit": "M1206", + "cabinet": "UC0206", + "pos": [ + 204364.4, + 286279.5 + ] + }, + { + "id": "BG3545", + "constant": "cInBG3545", + "hwAddress": "%E354.5", + "comment": "Stausensor Str.1 (ILS-CV M1206)", + "role": "sensorJam", + "unit": "M1206", + "cabinet": "UC0206", + "pos": [ + 204362.7, + 285968.4 + ] + }, + { + "id": "BG3546", + "constant": "cInBG3546", + "hwAddress": "%E354.6", + "comment": "Sensor Förderer voll (ILS-CV M1206)", + "role": "sensorConvFull", + "unit": "M1206", + "cabinet": "UC0206", + "pos": [ + 204356.5, + 285329.5 + ] + }, + { + "id": "BG3547", + "constant": "cInBG3547", + "hwAddress": "%E354.7", + "comment": "Prüfung MT Pos.2 (KR-K1201 Einfahrt Block 1.2.2)", + "role": "sensorPinQuery", + "unit": "K1201", + "cabinet": "UC0206", + "pos": [ + 200286.8, + 288122.4 + ] + }, + { + "id": "BG3550", + "constant": "cInBG3550", + "hwAddress": "%E355.0", + "comment": "Prüfung MT Pos.3 (KR-K1201 Einfahrt Block 1.2.2)", + "role": "sensorPinQuery", + "unit": "K1201", + "cabinet": "UC0206", + "pos": [ + 196643.8, + 288121.0 + ] + }, + { + "id": "BG3551", + "constant": "cInBG3551", + "hwAddress": "%E355.1", + "comment": "Prüfung MT Pos.4 (KR-K1201 Einfahrt Block 1.2.2)", + "role": "sensorPinQuery", + "unit": "K1201", + "cabinet": "UC0206", + "pos": [ + 193540.2, + 288122.4 + ] + }, + { + "id": "BG3552", + "constant": "cInBG3552", + "hwAddress": "%E355.2", + "comment": "Prüfung MT Pos.5 (KR-K1201 Einfahrt Block 1.2.2)", + "role": "sensorPinQuery", + "unit": "K1201", + "cabinet": "UC0206", + "pos": [ + 189411.3, + 288122.4 + ] + }, + { + "id": "BG3553", + "constant": "cInBG3553", + "hwAddress": "%E355.3", + "comment": "Stausensor MT vor Pinband (KR-K1201) Block 1.2.2", + "role": "sensorJam", + "unit": "K1201", + "cabinet": "UC0206", + "pos": [ + 188668.8, + 288122.5 + ] + }, + { + "id": "BG3570", + "constant": "cInBG3570", + "hwAddress": "%E357.0", + "comment": "Stausensor Str.1 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 203150.0, + 286695.7 + ] + }, + { + "id": "BG3571", + "constant": "cInBG3571", + "hwAddress": "%E357.1", + "comment": "Stausensor Str.2 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 202350.0, + 286822.4 + ] + }, + { + "id": "BG3572", + "constant": "cInBG3572", + "hwAddress": "%E357.2", + "comment": "Stausensor Str.3 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 201550.0, + 286822.4 + ] + }, + { + "id": "BG3573", + "constant": "cInBG3573", + "hwAddress": "%E357.3", + "comment": "Stausensor Str.4 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 200750.1, + 286822.1 + ] + }, + { + "id": "BG3574", + "constant": "cInBG3574", + "hwAddress": "%E357.4", + "comment": "Stausensor Str.5 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 199950.0, + 286822.4 + ] + }, + { + "id": "BG3575", + "constant": "cInBG3575", + "hwAddress": "%E357.5", + "comment": "Stausensor Str.6 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 199150.0, + 286822.4 + ] + }, + { + "id": "BG3576", + "constant": "cInBG3576", + "hwAddress": "%E357.6", + "comment": "Stausensor Str.7 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 197950.0, + 286822.4 + ] + }, + { + "id": "BG3577", + "constant": "cInBG3577", + "hwAddress": "%E357.7", + "comment": "Stausensor Str.8 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 197100.2, + 286822.4 + ] + }, + { + "id": "BG3580", + "constant": "cInBG3580", + "hwAddress": "%E358.0", + "comment": "Stausensor Str.9 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 196300.1, + 286822.3 + ] + }, + { + "id": "BG3581", + "constant": "cInBG3581", + "hwAddress": "%E358.1", + "comment": "Stausensor Str.10 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 195500.2, + 286822.0 + ] + }, + { + "id": "BG3582", + "constant": "cInBG3582", + "hwAddress": "%E358.2", + "comment": "Stausensor Str.11 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 194700.1, + 286822.3 + ] + }, + { + "id": "BG3583", + "constant": "cInBG3583", + "hwAddress": "%E358.3", + "comment": "Stausensor Str.12 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 193900.1, + 286822.3 + ] + }, + { + "id": "BG3584", + "constant": "cInBG3584", + "hwAddress": "%E358.4", + "comment": "Stausensor Str.13 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 193100.2, + 286822.0 + ] + }, + { + "id": "BG3585", + "constant": "cInBG3585", + "hwAddress": "%E358.5", + "comment": "Stausensor Str.14 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 191300.0, + 286822.3 + ] + }, + { + "id": "BG3586", + "constant": "cInBG3586", + "hwAddress": "%E358.6", + "comment": "Stausensor Str.15 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 190500.0, + 286822.3 + ] + }, + { + "id": "BG3587", + "constant": "cInBG3587", + "hwAddress": "%E358.7", + "comment": "Stausensor Str.16 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 189700.1, + 286822.0 + ] + }, + { + "id": "BG3590", + "constant": "cInBG3590", + "hwAddress": "%E359.0", + "comment": "Stausensor Str.17 (Block 1.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0206", + "pos": [ + 188900.0, + 286822.3 + ] + }, + { + "id": "BG3600", + "constant": "cInBG3600", + "hwAddress": "%E360.0", + "comment": "in Separator 2 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 207428.1, + 286728.5 + ] + }, + { + "id": "BG3601", + "constant": "cInBG3601", + "hwAddress": "%E360.1", + "comment": "Pin Abfrage (KR-M1202 ) Block 1.2.3", + "role": "sensorPinQuery", + "unit": "M1202", + "cabinet": "UC0207", + "pos": [ + 207166.5, + 287833.0 + ] + }, + { + "id": "BG3602", + "constant": "cInBG3602", + "hwAddress": "%E360.2", + "comment": "Prüfung MT Pos.1 (KR-K1202 Einfahrt Block 1.2.3)", + "role": "sensorPinQuery", + "unit": "K1202", + "cabinet": "UC0207", + "pos": [ + 207629.1, + 288128.1 + ] + }, + { + "id": "BG3603", + "constant": "cInBG3603", + "hwAddress": "%E360.3", + "comment": "Stausensor Str.2 (KR-M1202)", + "role": "sensorJam", + "unit": "M1202", + "cabinet": "UC0207", + "pos": [ + 206622.3, + 287121.2 + ] + }, + { + "id": "BG3604", + "constant": "cInBG3604", + "hwAddress": "%E360.4", + "comment": "in Separator 1 (ILS-CV M1207)", + "role": "sensorInSep", + "unit": "M1207", + "cabinet": "UC0207", + "pos": [ + 206614.7, + 286163.2 + ] + }, + { + "id": "BG3605", + "constant": "cInBG3605", + "hwAddress": "%E360.5", + "comment": "Stausensor Str.1 (KR-K1207 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K1207", + "cabinet": "UC0207", + "pos": [ + 206612.9, + 285852.1 + ] + }, + { + "id": "BG3606", + "constant": "cInBG3606", + "hwAddress": "%E360.6", + "comment": "Sensor Förderer voll (ILS-CV M1207)", + "role": "sensorConvFull", + "unit": "M1207", + "cabinet": "UC0207", + "pos": [ + 206608.8, + 285228.8 + ] + }, + { + "id": "BG3607", + "constant": "cInBG3607", + "hwAddress": "%E360.7", + "comment": "Prüfung MT Pos.2 (KR-K1202 Einfahrt Block 1.2.3)", + "role": "sensorPinQuery", + "unit": "K1202", + "cabinet": "UC0207", + "pos": [ + 211110.3, + 288116.2 + ] + }, + { + "id": "BG3610", + "constant": "cInBG3610", + "hwAddress": "%E361.0", + "comment": "Prüfung MT Pos.3 (KR-K1202 Einfahrt Block 1.2.3)", + "role": "sensorPinQuery", + "unit": "K1202", + "cabinet": "UC0207", + "pos": [ + 214297.9, + 288116.2 + ] + }, + { + "id": "BG3611", + "constant": "cInBG3611", + "hwAddress": "%E361.1", + "comment": "Prüfung MT Pos.4 (KR-K1202 Einfahrt Block 1.2.3)", + "role": "sensorPinQuery", + "unit": "K1202", + "cabinet": "UC0207", + "pos": [ + 218467.2, + 288478.4 + ] + }, + { + "id": "BG3612", + "constant": "cInBG3612", + "hwAddress": "%E361.2", + "comment": "Prüfung MT Pos.5 (KR-K1202 Einfahrt Block 1.2.3)", + "role": "sensorPinQuery", + "unit": "K1202", + "cabinet": "UC0207", + "pos": [ + 221679.0, + 288116.2 + ] + }, + { + "id": "BG3613", + "constant": "cInBG3613", + "hwAddress": "%E361.3", + "comment": "Prüfung MT Pos.6 (KR-K1202 Einfahrt Block 1.2.3)", + "role": "sensorPinQuery", + "unit": "K1202", + "cabinet": "UC0207", + "pos": [ + 225266.2, + 288116.2 + ] + }, + { + "id": "BG3614", + "constant": "cInBG3614", + "hwAddress": "%E361.4", + "comment": "in Separator 3 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 214544.0, + 288491.5 + ] + }, + { + "id": "BG3615", + "constant": "cInBG3615", + "hwAddress": "%E361.5", + "comment": "Stausensor (M1209)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 215007.9, + 289194.1 + ] + }, + { + "id": "BG3616", + "constant": "cInBG3616", + "hwAddress": "%E361.6", + "comment": "Sensor Förderer voll (ILS-CV M1209)", + "role": "sensorConvFull", + "unit": "M1209", + "cabinet": "UC0207", + "pos": [ + 217070.7, + 289486.8 + ] + }, + { + "id": "BG3617", + "constant": "cInBG3617", + "hwAddress": "%E361.7", + "comment": "in Separator 4 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 207474.9, + 288750.0 + ] + }, + { + "id": "BG3621", + "constant": "cInBG3621", + "hwAddress": "%E362.1", + "comment": "Stausensor 2 (KR-M1202)", + "role": "sensorJam", + "unit": "M1202", + "cabinet": "UC0207", + "pos": [ + 211984.0, + 288490.9 + ] + }, + { + "id": "BG3622", + "constant": "cInBG3622", + "hwAddress": "%E362.2", + "comment": "in Separator (ILS-CV M1209)", + "role": "sensorInSep", + "unit": "M1209", + "cabinet": "UC0207", + "pos": [ + 223412.7, + 439132.9 + ] + }, + { + "id": "BG3623", + "constant": "cInBG3623", + "hwAddress": "%E362.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1209)", + "role": "sensorFinger", + "unit": "M1209", + "cabinet": "UC0207", + "pos": [ + 222672.8, + 439406.3 + ] + }, + { + "id": "BG3624", + "constant": "cInBG3624", + "hwAddress": "%E362.4", + "comment": "MT in Position (ILS-CV M1209)", + "role": "sensorCarrInPos", + "unit": "M1209", + "cabinet": "UC0207", + "pos": [ + 221927.7, + 439402.9 + ] + }, + { + "id": "BG3625", + "constant": "cInBG3625", + "hwAddress": "%E362.5", + "comment": "Stausensor MT vor Pinband (KR-K1203) Block 1.2.3", + "role": "sensorJam", + "unit": "K1203", + "cabinet": "UC0207", + "pos": [ + 226369.5, + 287829.1 + ] + }, + { + "id": "BG3630", + "constant": "cInBG3630", + "hwAddress": "%E363.0", + "comment": "Stausensor Str.1 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 208400.3, + 286801.8 + ] + }, + { + "id": "BG3631", + "constant": "cInBG3631", + "hwAddress": "%E363.1", + "comment": "Stausensor Str.2 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 209200.3, + 286801.7 + ] + }, + { + "id": "BG3632", + "constant": "cInBG3632", + "hwAddress": "%E363.2", + "comment": "Stausensor Str.3 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 210000.3, + 286801.7 + ] + }, + { + "id": "BG3633", + "constant": "cInBG3633", + "hwAddress": "%E363.3", + "comment": "Stausensor Str.4 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 211146.4, + 286801.7 + ] + }, + { + "id": "BG3634", + "constant": "cInBG3634", + "hwAddress": "%E363.4", + "comment": "Stausensor Str.5 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 211946.4, + 286801.7 + ] + }, + { + "id": "BG3635", + "constant": "cInBG3635", + "hwAddress": "%E363.5", + "comment": "Stausensor Str.6 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 212746.4, + 286801.7 + ] + }, + { + "id": "BG3636", + "constant": "cInBG3636", + "hwAddress": "%E363.6", + "comment": "Stausensor Str.7 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 213545.6, + 286801.7 + ] + }, + { + "id": "BG3637", + "constant": "cInBG3637", + "hwAddress": "%E363.7", + "comment": "Stausensor Str.8 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 214346.4, + 286801.7 + ] + }, + { + "id": "BG3640", + "constant": "cInBG3640", + "hwAddress": "%E364.0", + "comment": "Stausensor Str.9 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 215146.4, + 286802.5 + ] + }, + { + "id": "BG3641", + "constant": "cInBG3641", + "hwAddress": "%E364.1", + "comment": "Stausensor Str.10 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 217150.3, + 286801.5 + ] + }, + { + "id": "BG3642", + "constant": "cInBG3642", + "hwAddress": "%E364.2", + "comment": "Stausensor Str.11 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 217950.3, + 286801.5 + ] + }, + { + "id": "BG3643", + "constant": "cInBG3643", + "hwAddress": "%E364.3", + "comment": "Stausensor Str.12 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 218750.3, + 286801.4 + ] + }, + { + "id": "BG3644", + "constant": "cInBG3644", + "hwAddress": "%E364.4", + "comment": "Stausensor Str.13 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 219549.4, + 286801.5 + ] + }, + { + "id": "BG3645", + "constant": "cInBG3645", + "hwAddress": "%E364.5", + "comment": "Stausensor Str.14 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 220350.3, + 286801.4 + ] + }, + { + "id": "BG3646", + "constant": "cInBG3646", + "hwAddress": "%E364.6", + "comment": "Stausensor Str.15 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 221150.3, + 286801.5 + ] + }, + { + "id": "BG3647", + "constant": "cInBG3647", + "hwAddress": "%E364.7", + "comment": "Stausensor Str.16 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 221950.3, + 286801.4 + ] + }, + { + "id": "BG3650", + "constant": "cInBG3650", + "hwAddress": "%E365.0", + "comment": "Stausensor Str.17 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 223150.3, + 286801.4 + ] + }, + { + "id": "BG3651", + "constant": "cInBG3651", + "hwAddress": "%E365.1", + "comment": "Stausensor Str.18 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 223950.3, + 286801.5 + ] + }, + { + "id": "BG3652", + "constant": "cInBG3652", + "hwAddress": "%E365.2", + "comment": "Stausensor Str.19 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 224748.7, + 286801.4 + ] + }, + { + "id": "BG3653", + "constant": "cInBG3653", + "hwAddress": "%E365.3", + "comment": "Stausensor Str.20 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 225550.3, + 286801.5 + ] + }, + { + "id": "BG3654", + "constant": "cInBG3654", + "hwAddress": "%E365.4", + "comment": "Stausensor Str.21 (Block 1.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 226350.3, + 286801.5 + ] + }, + { + "id": "BG3660", + "constant": "cInBG3660", + "hwAddress": "%E366.0", + "comment": "in Separator 2 (ILS-CV M1208)", + "role": "sensorInSep", + "unit": "M1208", + "cabinet": "UC0208", + "pos": [ + 227619.6, + 286850.7 + ] + }, + { + "id": "BG3661", + "constant": "cInBG3661", + "hwAddress": "%E366.1", + "comment": "Pin Abfrage (KR-M1202 ) Block 1.2.4", + "role": "sensorPinQuery", + "unit": "M1202", + "cabinet": "UC0208", + "pos": [ + 227916.6, + 287830.4 + ] + }, + { + "id": "BG3662", + "constant": "cInBG3662", + "hwAddress": "%E366.2", + "comment": "Prüfung MT Pos.1 (KR-K1202 Einfahrt Block 1.2.4)", + "role": "sensorPinQuery", + "unit": "K1202", + "cabinet": "UC0208", + "pos": [ + 228219.8, + 288126.8 + ] + }, + { + "id": "BG3663", + "constant": "cInBG3663", + "hwAddress": "%E366.3", + "comment": "Stausensor Str.2 (M1202)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 227157.2, + 287832.4 + ] + }, + { + "id": "BG3664", + "constant": "cInBG3664", + "hwAddress": "%E366.4", + "comment": "in Separator 1 (ILS-CV M1208)", + "role": "sensorInSep", + "unit": "M1208", + "cabinet": "UC0208", + "pos": [ + 227614.7, + 286268.5 + ] + }, + { + "id": "BG3665", + "constant": "cInBG3665", + "hwAddress": "%E366.5", + "comment": "Stausensor Str.1 (KR-M1208)", + "role": "sensorJam", + "unit": "M1208", + "cabinet": "UC0208", + "pos": [ + 227613.0, + 285957.3 + ] + }, + { + "id": "BG3666", + "constant": "cInBG3666", + "hwAddress": "%E366.6", + "comment": "Sensor Förderer voll (ILS-CV M1208)", + "role": "sensorConvFull", + "unit": "M1208", + "cabinet": "UC0208", + "pos": [ + 227612.5, + 285348.3 + ] + }, + { + "id": "BG3667", + "constant": "cInBG3667", + "hwAddress": "%E366.7", + "comment": "Prüfung MT Pos.2 (KR-K1202 Einfahrt Block 1.2.4)", + "role": "sensorPinQuery", + "unit": "K1202", + "cabinet": "UC0208", + "pos": [ + 231576.8, + 288129.8 + ] + }, + { + "id": "BG3670", + "constant": "cInBG3670", + "hwAddress": "%E367.0", + "comment": "Prüfung MT Pos.3 (KR-K1202 Einfahrt Block 1.2.4)", + "role": "sensorPinQuery", + "unit": "K1202", + "cabinet": "UC0208", + "pos": [ + 235283.9, + 287131.5 + ] + }, + { + "id": "BG3671", + "constant": "cInBG3671", + "hwAddress": "%E367.1", + "comment": "Prüfung MT Pos.4 (KR-K1202 Einfahrt Block 1.2.4)", + "role": "sensorPinQuery", + "unit": "K1202", + "cabinet": "UC0208", + "pos": [ + 238060.2, + 288118.9 + ] + }, + { + "id": "BG3690", + "constant": "cInBG3690", + "hwAddress": "%E369.0", + "comment": "Stausensor Str.1 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 229150.3, + 286800.9 + ] + }, + { + "id": "BG3691", + "constant": "cInBG3691", + "hwAddress": "%E369.1", + "comment": "Stausensor Str.2 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 229950.3, + 286800.8 + ] + }, + { + "id": "BG3692", + "constant": "cInBG3692", + "hwAddress": "%E369.2", + "comment": "Stausensor Str.3 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 230750.3, + 286800.8 + ] + }, + { + "id": "BG3693", + "constant": "cInBG3693", + "hwAddress": "%E369.3", + "comment": "Stausensor Str.4 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 231550.3, + 286800.7 + ] + }, + { + "id": "BG3694", + "constant": "cInBG3694", + "hwAddress": "%E369.4", + "comment": "Stausensor Str.5 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 232350.3, + 286800.7 + ] + }, + { + "id": "BG3695", + "constant": "cInBG3695", + "hwAddress": "%E369.5", + "comment": "Stausensor Str.6 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 233150.3, + 286800.8 + ] + }, + { + "id": "BG3696", + "constant": "cInBG3696", + "hwAddress": "%E369.6", + "comment": "Stausensor Str.7 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 233949.4, + 286800.7 + ] + }, + { + "id": "BG3697", + "constant": "cInBG3697", + "hwAddress": "%E369.7", + "comment": "Stausensor Str.8 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 235150.3, + 286801.5 + ] + }, + { + "id": "BG3700", + "constant": "cInBG3700", + "hwAddress": "%E370.0", + "comment": "Stausensor Str.9 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 235950.3, + 286801.5 + ] + }, + { + "id": "BG3701", + "constant": "cInBG3701", + "hwAddress": "%E370.1", + "comment": "Stausensor Str.10 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 236750.3, + 286800.6 + ] + }, + { + "id": "BG3702", + "constant": "cInBG3702", + "hwAddress": "%E370.2", + "comment": "Stausensor Str.11 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 237550.3, + 286800.6 + ] + }, + { + "id": "BG3703", + "constant": "cInBG3703", + "hwAddress": "%E370.3", + "comment": "Stausensor Str.12 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 238350.3, + 286800.5 + ] + }, + { + "id": "BG3704", + "constant": "cInBG3704", + "hwAddress": "%E370.4", + "comment": "Stausensor Str.13 (Block 1.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 239149.4, + 286800.5 + ] + }, + { + "id": "BG3720", + "constant": "cInBG3720", + "hwAddress": "%E372.0", + "comment": "in Separator 1 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 186664.6, + 271559.5 + ] + }, + { + "id": "BG3721", + "constant": "cInBG3721", + "hwAddress": "%E372.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1205)", + "role": "sensorJam", + "unit": "M1205", + "cabinet": "UC2201", + "pos": [ + 187300.2, + 272818.2 + ] + }, + { + "id": "BG3722", + "constant": "cInBG3722", + "hwAddress": "%E372.2", + "comment": "Stausensor 1 (KR-M1203 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1203", + "cabinet": "UC2201", + "pos": [ + 186431.0, + 272542.8 + ] + }, + { + "id": "BG3723", + "constant": "cInBG3723", + "hwAddress": "%E372.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1205)", + "role": "sensorFinger", + "unit": "M1205", + "cabinet": "UC2201", + "pos": [ + 187302.9, + 273688.7 + ] + }, + { + "id": "BG3724", + "constant": "cInBG3724", + "hwAddress": "%E372.4", + "comment": "in Separator 2 (ILS-CV M1205)", + "role": "sensorInSep", + "unit": "M1205", + "cabinet": "UC2201", + "pos": [ + 187300.2, + 273116.7 + ] + }, + { + "id": "BG3725", + "constant": "cInBG3725", + "hwAddress": "%E372.5", + "comment": "in Separator (KR-M1203)", + "role": "sensorInSep", + "unit": "M1203", + "cabinet": "UC2201", + "pos": [ + 170660.3, + 270880.1 + ] + }, + { + "id": "BG3727", + "constant": "cInBG3727", + "hwAddress": "%E372.7", + "comment": "MT in Position (ILS-CV M1205)", + "role": "sensorCarrInPos", + "unit": "M1205", + "cabinet": "UC2201", + "pos": [ + 187300.2, + 273960.1 + ] + }, + { + "id": "BG3750", + "constant": "cInBG3750", + "hwAddress": "%E375.0", + "comment": "in Separator 1 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 185950.0, + 273167.6 + ] + }, + { + "id": "BG3751", + "constant": "cInBG3751", + "hwAddress": "%E375.1", + "comment": "in Separator 2 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 185150.0, + 273167.6 + ] + }, + { + "id": "BG3752", + "constant": "cInBG3752", + "hwAddress": "%E375.2", + "comment": "in Separator 3 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 184350.0, + 273167.6 + ] + }, + { + "id": "BG3753", + "constant": "cInBG3753", + "hwAddress": "%E375.3", + "comment": "in Separator 4 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 183550.0, + 273167.6 + ] + }, + { + "id": "BG3754", + "constant": "cInBG3754", + "hwAddress": "%E375.4", + "comment": "in Separator 5 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 182750.0, + 273167.6 + ] + }, + { + "id": "BG3755", + "constant": "cInBG3755", + "hwAddress": "%E375.5", + "comment": "in Separator 6 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 181950.0, + 273167.6 + ] + }, + { + "id": "BG3756", + "constant": "cInBG3756", + "hwAddress": "%E375.6", + "comment": "in Separator 7 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 181150.0, + 273167.6 + ] + }, + { + "id": "BG3757", + "constant": "cInBG3757", + "hwAddress": "%E375.7", + "comment": "in Separator 8 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 179149.9, + 273167.6 + ] + }, + { + "id": "BG3760", + "constant": "cInBG3760", + "hwAddress": "%E376.0", + "comment": "in Separator 9 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 178349.9, + 273167.6 + ] + }, + { + "id": "BG3761", + "constant": "cInBG3761", + "hwAddress": "%E376.1", + "comment": "in Separator 10 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 177549.9, + 273167.6 + ] + }, + { + "id": "BG3762", + "constant": "cInBG3762", + "hwAddress": "%E376.2", + "comment": "in Separator 11 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 176749.9, + 273167.6 + ] + }, + { + "id": "BG3763", + "constant": "cInBG3763", + "hwAddress": "%E376.3", + "comment": "in Separator 12 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 175949.9, + 273167.6 + ] + }, + { + "id": "BG3764", + "constant": "cInBG3764", + "hwAddress": "%E376.4", + "comment": "in Separator 13 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 175149.9, + 273167.6 + ] + }, + { + "id": "BG3765", + "constant": "cInBG3765", + "hwAddress": "%E376.5", + "comment": "in Separator 14 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 174000.0, + 273167.6 + ] + }, + { + "id": "BG3766", + "constant": "cInBG3766", + "hwAddress": "%E376.6", + "comment": "in Separator 15 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 173200.0, + 273167.6 + ] + }, + { + "id": "BG3767", + "constant": "cInBG3767", + "hwAddress": "%E376.7", + "comment": "in Separator 16 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 172400.0, + 273167.6 + ] + }, + { + "id": "BG3770", + "constant": "cInBG3770", + "hwAddress": "%E377.0", + "comment": "in Separator 17 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 171600.0, + 273167.6 + ] + }, + { + "id": "BG3771", + "constant": "cInBG3771", + "hwAddress": "%E377.1", + "comment": "in Separator 18 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 170800.0, + 273167.6 + ] + }, + { + "id": "BG3772", + "constant": "cInBG3772", + "hwAddress": "%E377.2", + "comment": "In Separator 19 (Block 1.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2201", + "pos": [ + 170000.0, + 273167.6 + ] + }, + { + "id": "BG3780", + "constant": "cInBG3780", + "hwAddress": "%E378.0", + "comment": "in Separator 1 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 203432.0, + 271583.2 + ] + }, + { + "id": "BG3781", + "constant": "cInBG3781", + "hwAddress": "%E378.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1206)", + "role": "sensorJam", + "unit": "M1206", + "cabinet": "UC2202", + "pos": [ + 204502.1, + 272818.3 + ] + }, + { + "id": "BG3782", + "constant": "cInBG3782", + "hwAddress": "%E378.2", + "comment": "Stausensor 1 (KR-M1203 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1203", + "cabinet": "UC2202", + "pos": [ + 203632.9, + 272542.9 + ] + }, + { + "id": "BG3783", + "constant": "cInBG3783", + "hwAddress": "%E378.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1206)", + "role": "sensorFinger", + "unit": "M1206", + "cabinet": "UC2202", + "pos": [ + 204504.8, + 273714.9 + ] + }, + { + "id": "BG3784", + "constant": "cInBG3784", + "hwAddress": "%E378.4", + "comment": "in Separator 2 (ILS-CV M1206)", + "role": "sensorInSep", + "unit": "M1206", + "cabinet": "UC2202", + "pos": [ + 204502.1, + 273114.4 + ] + }, + { + "id": "BG3785", + "constant": "cInBG3785", + "hwAddress": "%E378.5", + "comment": "Stausensor 3 (KR-M1203)", + "role": "sensorJam", + "unit": "M1203", + "cabinet": "UC2202", + "pos": [ + 203727.2, + 271103.1 + ] + }, + { + "id": "BG3786", + "constant": "cInBG3786", + "hwAddress": "%E378.6", + "comment": "Rad dreht (KR-M1203)", + "role": "sensorWheel", + "unit": "M1203", + "cabinet": "UC2202", + "pos": [ + 204256.3, + 270785.7 + ] + }, + { + "id": "BG3787", + "constant": "cInBG3787", + "hwAddress": "%E378.7", + "comment": "MT in Position (ILS-CV M1206)", + "role": "sensorCarrInPos", + "unit": "M1206", + "cabinet": "UC3202", + "pos": [ + 204502.1, + 273985.6 + ] + }, + { + "id": "BG3810", + "constant": "cInBG3810", + "hwAddress": "%E381.0", + "comment": "in Separator 1 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 203151.9, + 273167.8 + ] + }, + { + "id": "BG3811", + "constant": "cInBG3811", + "hwAddress": "%E381.1", + "comment": "in Separator 2 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 202351.9, + 273167.8 + ] + }, + { + "id": "BG3812", + "constant": "cInBG3812", + "hwAddress": "%E381.2", + "comment": "in Separator 3 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 201551.9, + 273167.8 + ] + }, + { + "id": "BG3813", + "constant": "cInBG3813", + "hwAddress": "%E381.3", + "comment": "in Separator 4 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 200751.9, + 273167.8 + ] + }, + { + "id": "BG3814", + "constant": "cInBG3814", + "hwAddress": "%E381.4", + "comment": "in Separator 5 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 199951.9, + 273167.8 + ] + }, + { + "id": "BG3815", + "constant": "cInBG3815", + "hwAddress": "%E381.5", + "comment": "in Separator 6 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 199151.9, + 273167.8 + ] + }, + { + "id": "BG3816", + "constant": "cInBG3816", + "hwAddress": "%E381.6", + "comment": "in Separator 7 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 197951.9, + 273167.8 + ] + }, + { + "id": "BG3817", + "constant": "cInBG3817", + "hwAddress": "%E381.7", + "comment": "in Separator 8 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 197101.9, + 273167.8 + ] + }, + { + "id": "BG3820", + "constant": "cInBG3820", + "hwAddress": "%E382.0", + "comment": "in Separator 9 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 196301.9, + 273167.8 + ] + }, + { + "id": "BG3821", + "constant": "cInBG3821", + "hwAddress": "%E382.1", + "comment": "in Separator 10 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 195501.9, + 273167.8 + ] + }, + { + "id": "BG3822", + "constant": "cInBG3822", + "hwAddress": "%E382.2", + "comment": "in Separator 11 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 194701.9, + 273167.8 + ] + }, + { + "id": "BG3823", + "constant": "cInBG3823", + "hwAddress": "%E382.3", + "comment": "in Separator 12 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 193901.9, + 273167.8 + ] + }, + { + "id": "BG3824", + "constant": "cInBG3824", + "hwAddress": "%E382.4", + "comment": "in Separator 13 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 193101.9, + 273167.8 + ] + }, + { + "id": "BG3825", + "constant": "cInBG3825", + "hwAddress": "%E382.5", + "comment": "in Separator 14 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 191301.9, + 273167.8 + ] + }, + { + "id": "BG3826", + "constant": "cInBG3826", + "hwAddress": "%E382.6", + "comment": "in Separator 15 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 190501.9, + 273167.8 + ] + }, + { + "id": "BG3827", + "constant": "cInBG3827", + "hwAddress": "%E382.7", + "comment": "in Separator 16 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 189701.9, + 273167.8 + ] + }, + { + "id": "BG3830", + "constant": "cInBG3830", + "hwAddress": "%E383.0", + "comment": "in Separator 17 (Block 1.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2202", + "pos": [ + 188901.9, + 273167.8 + ] + }, + { + "id": "BG3840", + "constant": "cInBG3840", + "hwAddress": "%E384.0", + "comment": "in Separator 1 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 207894.6, + 271690.2 + ] + }, + { + "id": "BG3841", + "constant": "cInBG3841", + "hwAddress": "%E384.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1207 Block 1.2.3)", + "role": "sensorJam", + "unit": "M1207", + "cabinet": "UC2203", + "pos": [ + 206541.8, + 272816.8 + ] + }, + { + "id": "BG3842", + "constant": "cInBG3842", + "hwAddress": "%E384.2", + "comment": "Stausensor 1 (KR-M1204 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1204", + "cabinet": "UC2203", + "pos": [ + 207432.5, + 272541.4 + ] + }, + { + "id": "BG3843", + "constant": "cInBG3843", + "hwAddress": "%E384.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1207)", + "role": "sensorFinger", + "unit": "M1207", + "cabinet": "UC2203", + "pos": [ + 206544.5, + 273738.1 + ] + }, + { + "id": "BG3844", + "constant": "cInBG3844", + "hwAddress": "%E384.4", + "comment": "in Separator 2 (ILS-CV M1207)", + "role": "sensorInSep", + "unit": "M1207", + "cabinet": "UC2203", + "pos": [ + 206541.8, + 273108.3 + ] + }, + { + "id": "BG3845", + "constant": "cInBG3845", + "hwAddress": "%E384.5", + "comment": "Stausensor (ILS-CV-M1204)", + "role": "sensorJam", + "unit": "M1204", + "cabinet": "UC2203", + "pos": [ + 205932.8, + 270789.9 + ] + }, + { + "id": "BG3847", + "constant": "cInBG3847", + "hwAddress": "%E384.7", + "comment": "MT in Position (ILS-CV M1207)", + "role": "sensorCarrInPos", + "unit": "M1207", + "cabinet": "UC2203", + "pos": [ + 206541.8, + 274008.8 + ] + }, + { + "id": "BG3870", + "constant": "cInBG3870", + "hwAddress": "%E387.0", + "comment": "in Separator 1 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 208401.5, + 273166.2 + ] + }, + { + "id": "BG3871", + "constant": "cInBG3871", + "hwAddress": "%E387.1", + "comment": "in Separator 2 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 209201.5, + 273166.2 + ] + }, + { + "id": "BG3872", + "constant": "cInBG3872", + "hwAddress": "%E387.2", + "comment": "in Separator 3 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 210001.5, + 273166.2 + ] + }, + { + "id": "BG3873", + "constant": "cInBG3873", + "hwAddress": "%E387.3", + "comment": "in Separator 4 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 211151.5, + 273166.2 + ] + }, + { + "id": "BG3874", + "constant": "cInBG3874", + "hwAddress": "%E387.4", + "comment": "in Separator 5 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 211951.5, + 273166.2 + ] + }, + { + "id": "BG3875", + "constant": "cInBG3875", + "hwAddress": "%E387.5", + "comment": "in Separator 6 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 212751.5, + 273166.2 + ] + }, + { + "id": "BG3876", + "constant": "cInBG3876", + "hwAddress": "%E387.6", + "comment": "in Separator 7 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 213551.5, + 273166.2 + ] + }, + { + "id": "BG3877", + "constant": "cInBG3877", + "hwAddress": "%E387.7", + "comment": "in Separator 8 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 214351.5, + 273166.2 + ] + }, + { + "id": "BG3880", + "constant": "cInBG3880", + "hwAddress": "%E388.0", + "comment": "in Separator 9 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 215151.5, + 273166.2 + ] + }, + { + "id": "BG3881", + "constant": "cInBG3881", + "hwAddress": "%E388.1", + "comment": "in Separator 10 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 217151.5, + 273166.2 + ] + }, + { + "id": "BG3882", + "constant": "cInBG3882", + "hwAddress": "%E388.2", + "comment": "in Separator 11 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 217951.5, + 273166.2 + ] + }, + { + "id": "BG3883", + "constant": "cInBG3883", + "hwAddress": "%E388.3", + "comment": "in Separator 12 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 218751.5, + 273166.2 + ] + }, + { + "id": "BG3884", + "constant": "cInBG3884", + "hwAddress": "%E388.4", + "comment": "in Separator 13 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 219551.5, + 273166.2 + ] + }, + { + "id": "BG3885", + "constant": "cInBG3885", + "hwAddress": "%E388.5", + "comment": "in Separator 14 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 220351.5, + 273166.2 + ] + }, + { + "id": "BG3886", + "constant": "cInBG3886", + "hwAddress": "%E388.6", + "comment": "in Separator 15 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 221151.5, + 273166.2 + ] + }, + { + "id": "BG3887", + "constant": "cInBG3887", + "hwAddress": "%E388.7", + "comment": "in Separator 16 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 221951.5, + 273166.2 + ] + }, + { + "id": "BG3890", + "constant": "cInBG3890", + "hwAddress": "%E389.0", + "comment": "in Separator 17 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 223151.5, + 273166.2 + ] + }, + { + "id": "BG3891", + "constant": "cInBG3891", + "hwAddress": "%E389.1", + "comment": "in Separator 18 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 223951.5, + 273166.2 + ] + }, + { + "id": "BG3892", + "constant": "cInBG3892", + "hwAddress": "%E389.2", + "comment": "in Separator 19 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 224751.5, + 273166.2 + ] + }, + { + "id": "BG3893", + "constant": "cInBG3893", + "hwAddress": "%E389.3", + "comment": "in Separator 20 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 225551.5, + 273166.2 + ] + }, + { + "id": "BG3894", + "constant": "cInBG3894", + "hwAddress": "%E389.4", + "comment": "in Separator 21 (Block 1.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2203", + "pos": [ + 226351.5, + 273166.2 + ] + }, + { + "id": "BG3900", + "constant": "cInBG3900", + "hwAddress": "%E390.0", + "comment": "in Separator 1 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 228307.3, + 271624.4 + ] + }, + { + "id": "BG3901", + "constant": "cInBG3901", + "hwAddress": "%E390.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1208)", + "role": "sensorJam", + "unit": "M1208", + "cabinet": "UC2204", + "pos": [ + 227501.9, + 272818.2 + ] + }, + { + "id": "BG3902", + "constant": "cInBG3902", + "hwAddress": "%E390.2", + "comment": "Stausensor 1 (KR-M1204 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1204", + "cabinet": "UC2204", + "pos": [ + 228273.8, + 272542.8 + ] + }, + { + "id": "BG3903", + "constant": "cInBG3903", + "hwAddress": "%E390.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1208)", + "role": "sensorFinger", + "unit": "M1208", + "cabinet": "UC2204", + "pos": [ + 227504.6, + 273682.7 + ] + }, + { + "id": "BG3904", + "constant": "cInBG3904", + "hwAddress": "%E390.4", + "comment": "in Separator 2 (ILS-CV M1208)", + "role": "sensorInSep", + "unit": "M1208", + "cabinet": "UC2204", + "pos": [ + 227501.9, + 273111.8 + ] + }, + { + "id": "BG3905", + "constant": "cInBG3905", + "hwAddress": "%E390.5", + "comment": "in Separator 3 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 227178.5, + 270519.9 + ] + }, + { + "id": "BG3906", + "constant": "cInBG3906", + "hwAddress": "%E390.6", + "comment": "Stausensor 1 (M1204)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 227947.7, + 270789.9 + ] + }, + { + "id": "BG3907", + "constant": "cInBG3907", + "hwAddress": "%E390.7", + "comment": "MT in Position (ILS-CV M1208)", + "role": "sensorCarrInPos", + "unit": "M1208", + "cabinet": "UC2204", + "pos": [ + 227501.9, + 273949.2 + ] + }, + { + "id": "BG3910", + "constant": "cInBG3910", + "hwAddress": "%E391.0", + "comment": "Stausensor 2 (M2209)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 229108.5, + 270970.0 + ] + }, + { + "id": "BG3911", + "constant": "cInBG3911", + "hwAddress": "%E391.1", + "comment": "Rad dreht (KR-M1204)", + "role": "sensorWheel", + "unit": "M1204", + "cabinet": "UC2204", + "pos": [ + 238361.0, + 271792.6 + ] + }, + { + "id": "BG3912", + "constant": "cInBG3912", + "hwAddress": "%E391.2", + "comment": "Stausensor (KR-M1204)", + "role": "sensorJam", + "unit": "M1204", + "cabinet": "UC2204", + "pos": [ + 239527.4, + 272532.2 + ] + }, + { + "id": "BG3930", + "constant": "cInBG3930", + "hwAddress": "%E393.0", + "comment": "in Separator 1 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 229150.0, + 273167.6 + ] + }, + { + "id": "BG3931", + "constant": "cInBG3931", + "hwAddress": "%E393.1", + "comment": "in Separator 2 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 229950.0, + 273167.6 + ] + }, + { + "id": "BG3932", + "constant": "cInBG3932", + "hwAddress": "%E393.2", + "comment": "in Separator 3 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 230750.0, + 273167.6 + ] + }, + { + "id": "BG3933", + "constant": "cInBG3933", + "hwAddress": "%E393.3", + "comment": "in Separator 4 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 231550.0, + 273167.6 + ] + }, + { + "id": "BG3934", + "constant": "cInBG3934", + "hwAddress": "%E393.4", + "comment": "in Separator 5 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 232350.0, + 273167.6 + ] + }, + { + "id": "BG3935", + "constant": "cInBG3935", + "hwAddress": "%E393.5", + "comment": "in Separator 6 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 233150.0, + 273167.6 + ] + }, + { + "id": "BG3936", + "constant": "cInBG3936", + "hwAddress": "%E393.6", + "comment": "in Separator 7 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 233950.0, + 273167.6 + ] + }, + { + "id": "BG3937", + "constant": "cInBG3937", + "hwAddress": "%E393.7", + "comment": "in Separator 8 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 235150.0, + 273167.6 + ] + }, + { + "id": "BG3940", + "constant": "cInBG3940", + "hwAddress": "%E394.0", + "comment": "in Separator 9 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 235950.0, + 273167.6 + ] + }, + { + "id": "BG3941", + "constant": "cInBG3941", + "hwAddress": "%E394.1", + "comment": "in Separator 10 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 236750.0, + 273167.6 + ] + }, + { + "id": "BG3942", + "constant": "cInBG3942", + "hwAddress": "%E394.2", + "comment": "in Separator 11 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 237550.0, + 273167.6 + ] + }, + { + "id": "BG3943", + "constant": "cInBG3943", + "hwAddress": "%E394.3", + "comment": "in Separator 12 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 238350.0, + 273167.6 + ] + }, + { + "id": "BG3944", + "constant": "cInBG3944", + "hwAddress": "%E394.4", + "comment": "in Separator 13 (Block 1.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2204", + "pos": [ + 239150.0, + 273167.6 + ] + }, + { + "id": "BG3960", + "constant": "cInBG3960", + "hwAddress": "%E396.0", + "comment": "in Separator 1 (ILS-CV M1305)", + "role": "sensorInSep", + "unit": "M1305", + "cabinet": "UC2205", + "pos": [ + 186488.6, + 266652.0 + ] + }, + { + "id": "BG3961", + "constant": "cInBG3961", + "hwAddress": "%E396.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1305)", + "role": "sensorJam", + "unit": "M1305", + "cabinet": "UC2205", + "pos": [ + 187179.7, + 266348.9 + ] + }, + { + "id": "BG3962", + "constant": "cInBG3962", + "hwAddress": "%E396.2", + "comment": "Stausensor 1 (KR-M1301 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1301", + "cabinet": "UC2205", + "pos": [ + 186431.0, + 267635.3 + ] + }, + { + "id": "BG3963", + "constant": "cInBG3963", + "hwAddress": "%E396.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1305)", + "role": "sensorFinger", + "unit": "M1305", + "cabinet": "UC2205", + "pos": [ + 187184.5, + 265484.7 + ] + }, + { + "id": "BG3964", + "constant": "cInBG3964", + "hwAddress": "%E396.4", + "comment": "in Separator 2 (ILS-CV M1305)", + "role": "sensorInSep", + "unit": "M1305", + "cabinet": "UC2205", + "pos": [ + 187179.7, + 265780.8 + ] + }, + { + "id": "BG3965", + "constant": "cInBG3965", + "hwAddress": "%E396.5", + "comment": "in Separator (KR-M1301)", + "role": "sensorInSep", + "unit": "M1301", + "cabinet": "UC2205", + "pos": [ + 170988.5, + 268304.3 + ] + }, + { + "id": "BG3967", + "constant": "cInBG3967", + "hwAddress": "%E396.7", + "comment": "MT in Position (ILS-CV M1305)", + "role": "sensorCarrInPos", + "unit": "M1305", + "cabinet": "UC2205", + "pos": [ + 187181.8, + 265215.4 + ] + }, + { + "id": "BG3990", + "constant": "cInBG3990", + "hwAddress": "%E399.0", + "comment": "in Separator 1 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 185950.0, + 266041.9 + ] + }, + { + "id": "BG3991", + "constant": "cInBG3991", + "hwAddress": "%E399.1", + "comment": "in Separator 2 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 185150.0, + 266041.9 + ] + }, + { + "id": "BG3992", + "constant": "cInBG3992", + "hwAddress": "%E399.2", + "comment": "in Separator 3 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 184350.0, + 266041.9 + ] + }, + { + "id": "BG3993", + "constant": "cInBG3993", + "hwAddress": "%E399.3", + "comment": "in Separator 4 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 183550.0, + 266041.9 + ] + }, + { + "id": "BG3994", + "constant": "cInBG3994", + "hwAddress": "%E399.4", + "comment": "in Separator 5 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 182750.0, + 266041.9 + ] + }, + { + "id": "BG3995", + "constant": "cInBG3995", + "hwAddress": "%E399.5", + "comment": "in Separator 6 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 181950.0, + 266041.9 + ] + }, + { + "id": "BG3996", + "constant": "cInBG3996", + "hwAddress": "%E399.6", + "comment": "in Separator 7 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 181150.0, + 266041.9 + ] + }, + { + "id": "BG3997", + "constant": "cInBG3997", + "hwAddress": "%E399.7", + "comment": "in Separator 8 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 179149.9, + 266041.9 + ] + }, + { + "id": "BG4000", + "constant": "cInBG4000", + "hwAddress": "%E400.0", + "comment": "in Separator 9 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 178349.9, + 266041.9 + ] + }, + { + "id": "BG4001", + "constant": "cInBG4001", + "hwAddress": "%E400.1", + "comment": "in Separator 10 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 177549.9, + 266041.9 + ] + }, + { + "id": "BG4002", + "constant": "cInBG4002", + "hwAddress": "%E400.2", + "comment": "in Separator 11 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 176749.9, + 266041.9 + ] + }, + { + "id": "BG4003", + "constant": "cInBG4003", + "hwAddress": "%E400.3", + "comment": "in Separator 12 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 175949.9, + 266041.9 + ] + }, + { + "id": "BG4004", + "constant": "cInBG4004", + "hwAddress": "%E400.4", + "comment": "in Separator 13 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 175149.9, + 266041.9 + ] + }, + { + "id": "BG4005", + "constant": "cInBG4005", + "hwAddress": "%E400.5", + "comment": "in Separator 14 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 174000.0, + 266041.9 + ] + }, + { + "id": "BG4006", + "constant": "cInBG4006", + "hwAddress": "%E400.6", + "comment": "in Separator 15 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 173200.0, + 266041.9 + ] + }, + { + "id": "BG4007", + "constant": "cInBG4007", + "hwAddress": "%E400.7", + "comment": "in Separator 16 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 172400.0, + 266041.9 + ] + }, + { + "id": "BG4010", + "constant": "cInBG4010", + "hwAddress": "%E401.0", + "comment": "in Separator 17 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 171600.0, + 266041.9 + ] + }, + { + "id": "BG4011", + "constant": "cInBG4011", + "hwAddress": "%E401.1", + "comment": "in Separator 18 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 170800.0, + 266041.9 + ] + }, + { + "id": "BG4012", + "constant": "cInBG4012", + "hwAddress": "%E401.2", + "comment": "In Separator 19 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2205", + "pos": [ + 170000.0, + 266041.9 + ] + }, + { + "id": "BG4020", + "constant": "cInBG4020", + "hwAddress": "%E402.0", + "comment": "in Separator 1 (ILS-KR M1301)", + "role": "sensorInSep", + "unit": "M1301", + "cabinet": "UC2206", + "pos": [ + 203688.6, + 266652.0 + ] + }, + { + "id": "BG4021", + "constant": "cInBG4021", + "hwAddress": "%E402.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1306)", + "role": "sensorJam", + "unit": "M1306", + "cabinet": "UC2206", + "pos": [ + 204379.8, + 266348.9 + ] + }, + { + "id": "BG4022", + "constant": "cInBG4022", + "hwAddress": "%E402.2", + "comment": "Stausensor 1 (KR-M1301 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1301", + "cabinet": "UC2206", + "pos": [ + 203282.3, + 267635.3 + ] + }, + { + "id": "BG4023", + "constant": "cInBG4023", + "hwAddress": "%E402.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1306)", + "role": "sensorFinger", + "unit": "M1306", + "cabinet": "UC2206", + "pos": [ + 204384.5, + 265493.9 + ] + }, + { + "id": "BG4024", + "constant": "cInBG4024", + "hwAddress": "%E402.4", + "comment": "in Separator 2 (ILS-CV M1306)", + "role": "sensorInSep", + "unit": "M1306", + "cabinet": "UC2206", + "pos": [ + 204379.8, + 265787.3 + ] + }, + { + "id": "BG4025", + "constant": "cInBG4025", + "hwAddress": "%E402.5", + "comment": "Stausensor 3 (KR-M1301)", + "role": "sensorJam", + "unit": "M1301", + "cabinet": "UC2206", + "pos": [ + 203741.7, + 268344.7 + ] + }, + { + "id": "BG4026", + "constant": "cInBG4026", + "hwAddress": "%E402.6", + "comment": "Rad dreht (KR-M1301)", + "role": "sensorWheel", + "unit": "M1301", + "cabinet": "UC2206", + "pos": [ + 204270.7, + 268602.8 + ] + }, + { + "id": "BG4027", + "constant": "cInBG4027", + "hwAddress": "%E402.7", + "comment": "MT in Position (ILS-CV M1306)", + "role": "sensorCarrInPos", + "unit": "M1306", + "cabinet": "UC2206", + "pos": [ + 204381.8, + 265224.5 + ] + }, + { + "id": "BG4050", + "constant": "cInBG4050", + "hwAddress": "%E405.0", + "comment": "in Separator 1 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 203150.0, + 266041.9 + ] + }, + { + "id": "BG4051", + "constant": "cInBG4051", + "hwAddress": "%E405.1", + "comment": "in Separator 2 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 202350.0, + 266041.9 + ] + }, + { + "id": "BG4052", + "constant": "cInBG4052", + "hwAddress": "%E405.2", + "comment": "in Separator 3 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 201550.0, + 266041.9 + ] + }, + { + "id": "BG4053", + "constant": "cInBG4053", + "hwAddress": "%E405.3", + "comment": "in Separator 4 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 200750.0, + 266041.9 + ] + }, + { + "id": "BG4054", + "constant": "cInBG4054", + "hwAddress": "%E405.4", + "comment": "in Separator 5 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 199950.0, + 266041.9 + ] + }, + { + "id": "BG4055", + "constant": "cInBG4055", + "hwAddress": "%E405.5", + "comment": "in Separator 6 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 199150.0, + 266041.9 + ] + }, + { + "id": "BG4056", + "constant": "cInBG4056", + "hwAddress": "%E405.6", + "comment": "in Separator 7 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 197950.0, + 266041.9 + ] + }, + { + "id": "BG4057", + "constant": "cInBG4057", + "hwAddress": "%E405.7", + "comment": "in Separator 8 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 197149.9, + 266041.9 + ] + }, + { + "id": "BG4060", + "constant": "cInBG4060", + "hwAddress": "%E406.0", + "comment": "in Separator 9 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 196349.9, + 266041.9 + ] + }, + { + "id": "BG4061", + "constant": "cInBG4061", + "hwAddress": "%E406.1", + "comment": "in Separator 10 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 195549.9, + 266041.9 + ] + }, + { + "id": "BG4062", + "constant": "cInBG4062", + "hwAddress": "%E406.2", + "comment": "in Separator 11 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 194749.9, + 266041.9 + ] + }, + { + "id": "BG4063", + "constant": "cInBG4063", + "hwAddress": "%E406.3", + "comment": "in Separator 12 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 193949.9, + 266041.9 + ] + }, + { + "id": "BG4064", + "constant": "cInBG4064", + "hwAddress": "%E406.4", + "comment": "in Separator 13 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 193149.9, + 266041.9 + ] + }, + { + "id": "BG4065", + "constant": "cInBG4065", + "hwAddress": "%E406.5", + "comment": "in Separator 14 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 191300.0, + 266041.9 + ] + }, + { + "id": "BG4066", + "constant": "cInBG4066", + "hwAddress": "%E406.6", + "comment": "in Separator 15 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 190500.0, + 266041.9 + ] + }, + { + "id": "BG4067", + "constant": "cInBG4067", + "hwAddress": "%E406.7", + "comment": "in Separator 16 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 189700.0, + 266041.9 + ] + }, + { + "id": "BG4070", + "constant": "cInBG4070", + "hwAddress": "%E407.0", + "comment": "in Separator 17 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2206", + "pos": [ + 188900.0, + 266041.9 + ] + }, + { + "id": "BG4080", + "constant": "cInBG4080", + "hwAddress": "%E408.0", + "comment": "in Separator 1 (ILS-CV M1302)", + "role": "sensorInSep", + "unit": "M1302", + "cabinet": "UC2207", + "pos": [ + 207201.6, + 266652.0 + ] + }, + { + "id": "BG4081", + "constant": "cInBG4081", + "hwAddress": "%E408.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1307)", + "role": "sensorJam", + "unit": "M1307", + "cabinet": "UC2207", + "pos": [ + 206437.9, + 266348.9 + ] + }, + { + "id": "BG4082", + "constant": "cInBG4082", + "hwAddress": "%E408.2", + "comment": "Stausensor 1 (KR-M1302 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1302", + "cabinet": "UC2207", + "pos": [ + 207420.0, + 267635.3 + ] + }, + { + "id": "BG4083", + "constant": "cInBG4083", + "hwAddress": "%E408.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1307)", + "role": "sensorFinger", + "unit": "M1307", + "cabinet": "UC2207", + "pos": [ + 206442.7, + 265495.6 + ] + }, + { + "id": "BG4084", + "constant": "cInBG4084", + "hwAddress": "%E408.4", + "comment": "in Separator 2 (ILS-CV M1307)", + "role": "sensorInSep", + "unit": "M1307", + "cabinet": "UC2207", + "pos": [ + 206437.9, + 265788.4 + ] + }, + { + "id": "BG4085", + "constant": "cInBG4085", + "hwAddress": "%E408.5", + "comment": "in Separator 3 (ILS-KR-M1302)", + "role": "sensorInSep", + "unit": "M1302", + "cabinet": "UC2207", + "pos": [ + 214411.0, + 268497.6 + ] + }, + { + "id": "BG4087", + "constant": "cInBG4087", + "hwAddress": "%E408.7", + "comment": "MT in Position (ILS-CV M1307)", + "role": "sensorCarrInPos", + "unit": "M1307", + "cabinet": "UC2207", + "pos": [ + 206438.6, + 265199.0 + ] + }, + { + "id": "BG4090", + "constant": "cInBG4090", + "hwAddress": "%E409.0", + "comment": "Stausensor (ILS-KR-M1302)", + "role": "sensorJam", + "unit": "M1302", + "cabinet": "UC2207", + "pos": [ + 205993.6, + 268602.8 + ] + }, + { + "id": "BG4091", + "constant": "cInBG4091", + "hwAddress": "%E409.1", + "comment": "Stausensor (ILS-KR-M2309)", + "role": "sensorJam", + "unit": "M2309", + "cabinet": "UC2207", + "pos": [ + 216481.1, + 267740.4 + ] + }, + { + "id": "BG4110", + "constant": "cInBG4110", + "hwAddress": "%E411.0", + "comment": "in Separator 1 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 208401.5, + 266053.7 + ] + }, + { + "id": "BG4111", + "constant": "cInBG4111", + "hwAddress": "%E411.1", + "comment": "in Separator 2 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 209201.5, + 266053.7 + ] + }, + { + "id": "BG4112", + "constant": "cInBG4112", + "hwAddress": "%E411.2", + "comment": "in Separator 3 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 210001.5, + 266053.7 + ] + }, + { + "id": "BG4113", + "constant": "cInBG4113", + "hwAddress": "%E411.3", + "comment": "in Separator 4 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 211151.5, + 266053.7 + ] + }, + { + "id": "BG4114", + "constant": "cInBG4114", + "hwAddress": "%E411.4", + "comment": "in Separator 5 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 211951.5, + 266053.7 + ] + }, + { + "id": "BG4115", + "constant": "cInBG4115", + "hwAddress": "%E411.5", + "comment": "in Separator 6 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 212751.5, + 266053.7 + ] + }, + { + "id": "BG4116", + "constant": "cInBG4116", + "hwAddress": "%E411.6", + "comment": "in Separator 7 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 213551.5, + 266053.7 + ] + }, + { + "id": "BG4117", + "constant": "cInBG4117", + "hwAddress": "%E411.7", + "comment": "in Separator 8 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 214351.5, + 266053.7 + ] + }, + { + "id": "BG4120", + "constant": "cInBG4120", + "hwAddress": "%E412.0", + "comment": "in Separator 9 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 215151.5, + 266053.7 + ] + }, + { + "id": "BG4121", + "constant": "cInBG4121", + "hwAddress": "%E412.1", + "comment": "in Separator 10 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 217151.5, + 266053.7 + ] + }, + { + "id": "BG4122", + "constant": "cInBG4122", + "hwAddress": "%E412.2", + "comment": "in Separator 11 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 217951.5, + 266053.7 + ] + }, + { + "id": "BG4123", + "constant": "cInBG4123", + "hwAddress": "%E412.3", + "comment": "in Separator 12 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 218751.5, + 266053.7 + ] + }, + { + "id": "BG4124", + "constant": "cInBG4124", + "hwAddress": "%E412.4", + "comment": "in Separator 13 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 219551.5, + 266053.7 + ] + }, + { + "id": "BG4125", + "constant": "cInBG4125", + "hwAddress": "%E412.5", + "comment": "in Separator 14 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 220351.5, + 266053.7 + ] + }, + { + "id": "BG4126", + "constant": "cInBG4126", + "hwAddress": "%E412.6", + "comment": "in Separator 15 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 221151.5, + 266053.7 + ] + }, + { + "id": "BG4127", + "constant": "cInBG4127", + "hwAddress": "%E412.7", + "comment": "in Separator 16 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 221951.5, + 266053.7 + ] + }, + { + "id": "BG4130", + "constant": "cInBG4130", + "hwAddress": "%E413.0", + "comment": "in Separator 17 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 223151.5, + 266053.7 + ] + }, + { + "id": "BG4131", + "constant": "cInBG4131", + "hwAddress": "%E413.1", + "comment": "in Separator 18 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 223951.5, + 266053.7 + ] + }, + { + "id": "BG4132", + "constant": "cInBG4132", + "hwAddress": "%E413.2", + "comment": "in Separator 19 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 224751.5, + 266053.7 + ] + }, + { + "id": "BG4133", + "constant": "cInBG4133", + "hwAddress": "%E413.3", + "comment": "in Separator 20 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 225551.5, + 266053.7 + ] + }, + { + "id": "BG4134", + "constant": "cInBG4134", + "hwAddress": "%E413.4", + "comment": "in Separator 21 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2207", + "pos": [ + 226351.5, + 266053.7 + ] + }, + { + "id": "BG4140", + "constant": "cInBG4140", + "hwAddress": "%E414.0", + "comment": "in Separator 1 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 228201.6, + 266652.0 + ] + }, + { + "id": "BG4141", + "constant": "cInBG4141", + "hwAddress": "%E414.1", + "comment": "Staumelder, Einfahrt (ILS-CV M1308)", + "role": "sensorJam", + "unit": "M1308", + "cabinet": "UC2208", + "pos": [ + 227438.0, + 266348.9 + ] + }, + { + "id": "BG4142", + "constant": "cInBG4142", + "hwAddress": "%E414.2", + "comment": "Stausensor 1 (KR-M1302 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M1302", + "cabinet": "UC2208", + "pos": [ + 228420.0, + 267635.3 + ] + }, + { + "id": "BG4143", + "constant": "cInBG4143", + "hwAddress": "%E414.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1308)", + "role": "sensorFinger", + "unit": "M1308", + "cabinet": "UC2208", + "pos": [ + 227442.7, + 265490.2 + ] + }, + { + "id": "BG4144", + "constant": "cInBG4144", + "hwAddress": "%E414.4", + "comment": "in Separator 2 (ILS-CV M1308)", + "role": "sensorInSep", + "unit": "M1308", + "cabinet": "UC2208", + "pos": [ + 227438.0, + 265786.5 + ] + }, + { + "id": "BG4147", + "constant": "cInBG4147", + "hwAddress": "%E414.7", + "comment": "MT in Position (ILS-CV M1308)", + "role": "sensorCarrInPos", + "unit": "M1308", + "cabinet": "UC2208", + "pos": [ + 227440.0, + 265220.8 + ] + }, + { + "id": "BG4150", + "constant": "cInBG4150", + "hwAddress": "%E415.0", + "comment": "Rad dreht (KR-M1302)", + "role": "sensorWheel", + "unit": "M1302", + "cabinet": "UC2208", + "pos": [ + 238488.1, + 267692.9 + ] + }, + { + "id": "BG4170", + "constant": "cInBG4170", + "hwAddress": "%E417.0", + "comment": "in Separator 1 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 229151.5, + 266053.7 + ] + }, + { + "id": "BG4171", + "constant": "cInBG4171", + "hwAddress": "%E417.1", + "comment": "in Separator 2 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 229951.5, + 266053.7 + ] + }, + { + "id": "BG4172", + "constant": "cInBG4172", + "hwAddress": "%E417.2", + "comment": "in Separator 3 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 230751.5, + 266053.7 + ] + }, + { + "id": "BG4173", + "constant": "cInBG4173", + "hwAddress": "%E417.3", + "comment": "in Separator 4 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 231550.0, + 266053.7 + ] + }, + { + "id": "BG4174", + "constant": "cInBG4174", + "hwAddress": "%E417.4", + "comment": "in Separator 5 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 232350.0, + 266053.7 + ] + }, + { + "id": "BG4175", + "constant": "cInBG4175", + "hwAddress": "%E417.5", + "comment": "in Separator 6 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 233150.0, + 266053.7 + ] + }, + { + "id": "BG4176", + "constant": "cInBG4176", + "hwAddress": "%E417.6", + "comment": "in Separator 7 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 233950.0, + 266053.7 + ] + }, + { + "id": "BG4177", + "constant": "cInBG4177", + "hwAddress": "%E417.7", + "comment": "in Separator 8 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 235150.0, + 266053.7 + ] + }, + { + "id": "BG4180", + "constant": "cInBG4180", + "hwAddress": "%E418.0", + "comment": "in Separator 9 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 235950.0, + 266053.7 + ] + }, + { + "id": "BG4181", + "constant": "cInBG4181", + "hwAddress": "%E418.1", + "comment": "in Separator 10 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 236751.5, + 266053.7 + ] + }, + { + "id": "BG4182", + "constant": "cInBG4182", + "hwAddress": "%E418.2", + "comment": "in Separator 11 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 237551.5, + 266053.7 + ] + }, + { + "id": "BG4183", + "constant": "cInBG4183", + "hwAddress": "%E418.3", + "comment": "in Separator 12 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 238351.5, + 266053.7 + ] + }, + { + "id": "BG4184", + "constant": "cInBG4184", + "hwAddress": "%E418.4", + "comment": "in Separator 13 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2208", + "pos": [ + 239151.5, + 266053.7 + ] + }, + { + "id": "BG4200", + "constant": "cInBG4200", + "hwAddress": "%E420.0", + "comment": "in Separator 2 (Block 1.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 187526.0, + 248861.1 + ] + }, + { + "id": "BG4201", + "constant": "cInBG4201", + "hwAddress": "%E420.1", + "comment": "Pin Abfrage (KR-M1303 ) Block 1.3.1", + "role": "sensorPinQuery", + "unit": "M1303", + "cabinet": "UC2301", + "pos": [ + 186612.9, + 250119.4 + ] + }, + { + "id": "BG4202", + "constant": "cInBG4202", + "hwAddress": "%E420.2", + "comment": "Prüfung MT Pos.1 (KR-K1303 Einfahrt Block 1.3.1)", + "role": "sensorPinQuery", + "unit": "K1303", + "cabinet": "UC2301", + "pos": [ + 186359.6, + 249824.2 + ] + }, + { + "id": "BG4203", + "constant": "cInBG4203", + "hwAddress": "%E420.3", + "comment": "Stausensor (KR-M1303)", + "role": "sensorJam", + "unit": "M1303", + "cabinet": "UC2301", + "pos": [ + 187373.2, + 249998.6 + ] + }, + { + "id": "BG4204", + "constant": "cInBG4204", + "hwAddress": "%E420.4", + "comment": "in Separator 1 (ILS-CV 1305)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 187034.5, + 250417.1 + ] + }, + { + "id": "BG4205", + "constant": "cInBG4205", + "hwAddress": "%E420.5", + "comment": "Stausensor Str.1 (KR-K1305)", + "role": "sensorJam", + "unit": "K1305", + "cabinet": "UC2301", + "pos": [ + 187034.8, + 250991.5 + ] + }, + { + "id": "BG4206", + "constant": "cInBG4206", + "hwAddress": "%E420.6", + "comment": "Sensor Förderer voll (ILS-CV 1305)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 187037.5, + 251605.6 + ] + }, + { + "id": "BG4207", + "constant": "cInBG4207", + "hwAddress": "%E420.7", + "comment": "Prüfung MT Pos.2 (KR-K1303 Einfahrt Block 1.3.1)", + "role": "sensorPinQuery", + "unit": "K1303", + "cabinet": "UC2301", + "pos": [ + 183191.4, + 248859.2 + ] + }, + { + "id": "BG4210", + "constant": "cInBG4210", + "hwAddress": "%E421.0", + "comment": "Prüfung MT Pos.3 (KR-K1303 Einfahrt Block 1.3.1)", + "role": "sensorPinQuery", + "unit": "K1303", + "cabinet": "UC2301", + "pos": [ + 178799.9, + 248853.8 + ] + }, + { + "id": "BG4211", + "constant": "cInBG4211", + "hwAddress": "%E421.1", + "comment": "Prüfung MT Pos.4 (KR-K1303 Einfahrt Block 1.3.1)", + "role": "sensorPinQuery", + "unit": "K1303", + "cabinet": "UC2301", + "pos": [ + 175587.3, + 248853.8 + ] + }, + { + "id": "BG4212", + "constant": "cInBG4212", + "hwAddress": "%E421.2", + "comment": "Prüfung MT Pos.5 (KR-K1303 Einfahrt Block 1.3.1)", + "role": "sensorPinQuery", + "unit": "K1303", + "cabinet": "UC2301", + "pos": [ + 172113.1, + 248853.8 + ] + }, + { + "id": "BG4230", + "constant": "cInBG4230", + "hwAddress": "%E423.0", + "comment": "Stausensor Str.1 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 185959.8, + 250440.3 + ] + }, + { + "id": "BG4231", + "constant": "cInBG4231", + "hwAddress": "%E423.1", + "comment": "Stausensor Str.2 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 185150.0, + 250199.1 + ] + }, + { + "id": "BG4232", + "constant": "cInBG4232", + "hwAddress": "%E423.2", + "comment": "Stausensor Str.3 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 184349.9, + 250199.1 + ] + }, + { + "id": "BG4233", + "constant": "cInBG4233", + "hwAddress": "%E423.3", + "comment": "Stausensor Str.4 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 183550.0, + 250198.8 + ] + }, + { + "id": "BG4234", + "constant": "cInBG4234", + "hwAddress": "%E423.4", + "comment": "Stausensor Str.5 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 182749.9, + 250199.1 + ] + }, + { + "id": "BG4235", + "constant": "cInBG4235", + "hwAddress": "%E423.5", + "comment": "Stausensor Str.6 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 181949.9, + 250199.1 + ] + }, + { + "id": "BG4236", + "constant": "cInBG4236", + "hwAddress": "%E423.6", + "comment": "Stausensor Str.7 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 181150.0, + 250198.8 + ] + }, + { + "id": "BG4237", + "constant": "cInBG4237", + "hwAddress": "%E423.7", + "comment": "Stausensor Str.8 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 179149.8, + 250198.7 + ] + }, + { + "id": "BG4240", + "constant": "cInBG4240", + "hwAddress": "%E424.0", + "comment": "Stausensor Str.9 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 178349.8, + 250198.7 + ] + }, + { + "id": "BG4241", + "constant": "cInBG4241", + "hwAddress": "%E424.1", + "comment": "Stausensor Str.10 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 177549.9, + 250198.5 + ] + }, + { + "id": "BG4242", + "constant": "cInBG4242", + "hwAddress": "%E424.2", + "comment": "Stausensor Str.11 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 176749.8, + 250198.7 + ] + }, + { + "id": "BG4243", + "constant": "cInBG4243", + "hwAddress": "%E424.3", + "comment": "Stausensor Str.12 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 175949.8, + 250198.7 + ] + }, + { + "id": "BG4244", + "constant": "cInBG4244", + "hwAddress": "%E424.4", + "comment": "Stausensor Str.13 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 175149.9, + 250198.5 + ] + }, + { + "id": "BG4245", + "constant": "cInBG4245", + "hwAddress": "%E424.5", + "comment": "Stausensor Str.14 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 173999.9, + 250198.7 + ] + }, + { + "id": "BG4246", + "constant": "cInBG4246", + "hwAddress": "%E424.6", + "comment": "Stausensor Str.15 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 173199.9, + 250198.7 + ] + }, + { + "id": "BG4247", + "constant": "cInBG4247", + "hwAddress": "%E424.7", + "comment": "Stausensor Str.16 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 172400.0, + 250198.5 + ] + }, + { + "id": "BG4250", + "constant": "cInBG4250", + "hwAddress": "%E425.0", + "comment": "Stausensor Str.17 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 171599.9, + 250198.7 + ] + }, + { + "id": "BG4251", + "constant": "cInBG4251", + "hwAddress": "%E425.1", + "comment": "Stausensor Str.18 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 170799.9, + 250198.7 + ] + }, + { + "id": "BG4252", + "constant": "cInBG4252", + "hwAddress": "%E425.2", + "comment": "Stausensor Str.19 (Block 1.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2301", + "pos": [ + 170000.0, + 250198.5 + ] + }, + { + "id": "BG4260", + "constant": "cInBG4260", + "hwAddress": "%E426.0", + "comment": "in Separator 2 (Block 1.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 204280.0, + 248835.2 + ] + }, + { + "id": "BG4261", + "constant": "cInBG4261", + "hwAddress": "%E426.1", + "comment": "Pin Abfrage (KR-M1303 ) Block 1.3.2", + "role": "sensorPinQuery", + "unit": "M1303", + "cabinet": "UC2302", + "pos": [ + 203763.4, + 250128.2 + ] + }, + { + "id": "BG4262", + "constant": "cInBG4262", + "hwAddress": "%E426.2", + "comment": "Prüfung MT Pos.1 (KR-K1303 Einfahrt Block 1.3.2)", + "role": "sensorPinQuery", + "unit": "K1303", + "cabinet": "UC2302", + "pos": [ + 203592.6, + 249808.7 + ] + }, + { + "id": "BG4263", + "constant": "cInBG4263", + "hwAddress": "%E426.3", + "comment": "Stausensor (KR-M1303)", + "role": "sensorJam", + "unit": "M1303", + "cabinet": "UC2302", + "pos": [ + 204530.3, + 249939.0 + ] + }, + { + "id": "BG4264", + "constant": "cInBG4264", + "hwAddress": "%E426.4", + "comment": "in Separator 1 (ILS-CV M1306)", + "role": "sensorInSep", + "unit": "M1306", + "cabinet": "UC2302", + "pos": [ + 204234.5, + 250417.1 + ] + }, + { + "id": "BG4265", + "constant": "cInBG4265", + "hwAddress": "%E426.5", + "comment": "Stausensor Str.1 (ILS-CV M1306)", + "role": "sensorJam", + "unit": "M1306", + "cabinet": "UC2302", + "pos": [ + 204234.8, + 250991.5 + ] + }, + { + "id": "BG4266", + "constant": "cInBG4266", + "hwAddress": "%E426.6", + "comment": "Sensor Förderer voll (ILS-CV M1306)", + "role": "sensorConvFull", + "unit": "M1306", + "cabinet": "UC2302", + "pos": [ + 204234.8, + 251593.2 + ] + }, + { + "id": "BG4267", + "constant": "cInBG4267", + "hwAddress": "%E426.7", + "comment": "Prüfung MT Pos.2 (KR-K1303 Einfahrt Block 1.3.2)", + "role": "sensorPinQuery", + "unit": "K1303", + "cabinet": "UC2302", + "pos": [ + 200391.4, + 248859.2 + ] + }, + { + "id": "BG4270", + "constant": "cInBG4270", + "hwAddress": "%E427.0", + "comment": "Prüfung MT Pos.3 (KR-K1303 Einfahrt Block 1.3.2)", + "role": "sensorPinQuery", + "unit": "K1303", + "cabinet": "UC2302", + "pos": [ + 196799.9, + 248853.8 + ] + }, + { + "id": "BG4271", + "constant": "cInBG4271", + "hwAddress": "%E427.1", + "comment": "Prüfung MT Pos.4 (KR-K1303 Einfahrt Block 1.3.2)", + "role": "sensorPinQuery", + "unit": "K1303", + "cabinet": "UC2302", + "pos": [ + 193587.3, + 248853.8 + ] + }, + { + "id": "BG4272", + "constant": "cInBG4272", + "hwAddress": "%E427.2", + "comment": "Prüfung MT Pos.5 (KR-K1303 Einfahrt Block 1.3.2)", + "role": "sensorPinQuery", + "unit": "K1303", + "cabinet": "UC2302", + "pos": [ + 189413.6, + 248853.8 + ] + }, + { + "id": "BG4273", + "constant": "cInBG4273", + "hwAddress": "%E427.3", + "comment": "Stausensor MT vor Pinband (KR-K1303) Block 1.3.2", + "role": "sensorJam", + "unit": "K1303", + "cabinet": "UC2302", + "pos": [ + 188610.7, + 248854.0 + ] + }, + { + "id": "BG4290", + "constant": "cInBG4290", + "hwAddress": "%E429.0", + "comment": "Stausensor Str.1 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 203159.8, + 250437.1 + ] + }, + { + "id": "BG4291", + "constant": "cInBG4291", + "hwAddress": "%E429.1", + "comment": "Stausensor Str.2 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 202350.0, + 250199.1 + ] + }, + { + "id": "BG4292", + "constant": "cInBG4292", + "hwAddress": "%E429.2", + "comment": "Stausensor Str.3 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 201549.9, + 250199.1 + ] + }, + { + "id": "BG4293", + "constant": "cInBG4293", + "hwAddress": "%E429.3", + "comment": "Stausensor Str.4 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 200750.0, + 250198.8 + ] + }, + { + "id": "BG4294", + "constant": "cInBG4294", + "hwAddress": "%E429.4", + "comment": "Stausensor Str.5 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 199949.9, + 250199.1 + ] + }, + { + "id": "BG4295", + "constant": "cInBG4295", + "hwAddress": "%E429.5", + "comment": "Stausensor Str.6 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 199149.9, + 250199.1 + ] + }, + { + "id": "BG4296", + "constant": "cInBG4296", + "hwAddress": "%E429.6", + "comment": "Stausensor Str.7 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 197950.0, + 250198.8 + ] + }, + { + "id": "BG4297", + "constant": "cInBG4297", + "hwAddress": "%E429.7", + "comment": "Stausensor Str.8 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 197149.8, + 250198.7 + ] + }, + { + "id": "BG4300", + "constant": "cInBG4300", + "hwAddress": "%E430.0", + "comment": "Stausensor Str.9 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 196349.8, + 250198.7 + ] + }, + { + "id": "BG4301", + "constant": "cInBG4301", + "hwAddress": "%E430.1", + "comment": "Stausensor Str.10 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 195549.9, + 250198.5 + ] + }, + { + "id": "BG4302", + "constant": "cInBG4302", + "hwAddress": "%E430.2", + "comment": "Stausensor Str.11 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 194749.8, + 250198.7 + ] + }, + { + "id": "BG4303", + "constant": "cInBG4303", + "hwAddress": "%E430.3", + "comment": "Stausensor Str.12 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 193949.8, + 250198.7 + ] + }, + { + "id": "BG4304", + "constant": "cInBG4304", + "hwAddress": "%E430.4", + "comment": "Stausensor Str.13 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 193149.9, + 250198.5 + ] + }, + { + "id": "BG4305", + "constant": "cInBG4305", + "hwAddress": "%E430.5", + "comment": "Stausensor Str.14 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 191299.9, + 250198.7 + ] + }, + { + "id": "BG4306", + "constant": "cInBG4306", + "hwAddress": "%E430.6", + "comment": "Stausensor Str.15 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 190499.9, + 250198.7 + ] + }, + { + "id": "BG4307", + "constant": "cInBG4307", + "hwAddress": "%E430.7", + "comment": "Stausensor Str.16 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 189700.0, + 250198.5 + ] + }, + { + "id": "BG4310", + "constant": "cInBG4310", + "hwAddress": "%E431.0", + "comment": "Stausensor Str.17 (Block 1.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2302", + "pos": [ + 188899.9, + 250198.7 + ] + }, + { + "id": "BG4320", + "constant": "cInBG4320", + "hwAddress": "%E432.0", + "comment": "in Separator 2 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 207440.6, + 248833.6 + ] + }, + { + "id": "BG4321", + "constant": "cInBG4321", + "hwAddress": "%E432.1", + "comment": "Pin Abfrage (KR-M1304) Block 1.3.3", + "role": "sensorPinQuery", + "unit": "M1304", + "cabinet": "UC2303", + "pos": [ + 207172.5, + 250128.3 + ] + }, + { + "id": "BG4322", + "constant": "cInBG4322", + "hwAddress": "%E432.2", + "comment": "Prüfung MT Pos.1 (KR-K1304 Einfahrt Block 1.3.3)", + "role": "sensorPinQuery", + "unit": "K1304", + "cabinet": "UC2303", + "pos": [ + 207454.4, + 249808.7 + ] + }, + { + "id": "BG4323", + "constant": "cInBG4323", + "hwAddress": "%E432.3", + "comment": "Stausensor (KR-M1304)", + "role": "sensorJam", + "unit": "M1304", + "cabinet": "UC2303", + "pos": [ + 206399.7, + 249948.7 + ] + }, + { + "id": "BG4324", + "constant": "cInBG4324", + "hwAddress": "%E432.4", + "comment": "in Separator 1 (ILS-CV M1307)", + "role": "sensorInSep", + "unit": "M1307", + "cabinet": "UC2303", + "pos": [ + 206399.4, + 250428.3 + ] + }, + { + "id": "BG4325", + "constant": "cInBG4325", + "hwAddress": "%E432.5", + "comment": "Stausensor Str.1 (ILS-CV M1307)", + "role": "sensorJam", + "unit": "M1307", + "cabinet": "UC2303", + "pos": [ + 206399.7, + 251002.7 + ] + }, + { + "id": "BG4326", + "constant": "cInBG4326", + "hwAddress": "%E432.6", + "comment": "Sensor Förderer voll (ILS-CV 1307)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 206399.7, + 251604.3 + ] + }, + { + "id": "BG4327", + "constant": "cInBG4327", + "hwAddress": "%E432.7", + "comment": "Prüfung MT Pos.2 (KR-K1304 Einfahrt Block 1.3.3)", + "role": "sensorPinQuery", + "unit": "K1304", + "cabinet": "UC2303", + "pos": [ + 211112.4, + 248849.9 + ] + }, + { + "id": "BG4330", + "constant": "cInBG4330", + "hwAddress": "%E433.0", + "comment": "Prüfung MT Pos.3 (KR-K1304 Einfahrt Block 1.3.3)", + "role": "sensorPinQuery", + "unit": "K1304", + "cabinet": "UC2303", + "pos": [ + 214467.8, + 248847.2 + ] + }, + { + "id": "BG4331", + "constant": "cInBG4331", + "hwAddress": "%E433.1", + "comment": "Prüfung MT Pos.4 (KR-K1304 Einfahrt Block 1.3.3)", + "role": "sensorPinQuery", + "unit": "K1304", + "cabinet": "UC2303", + "pos": [ + 218467.0, + 248849.9 + ] + }, + { + "id": "BG4332", + "constant": "cInBG4332", + "hwAddress": "%E433.2", + "comment": "Prüfung MT Pos.5 (KR-K1304 Einfahrt Block 1.3.3)", + "role": "sensorPinQuery", + "unit": "K1304", + "cabinet": "UC2303", + "pos": [ + 221675.6, + 248849.9 + ] + }, + { + "id": "BG4333", + "constant": "cInBG4333", + "hwAddress": "%E433.3", + "comment": "Prüfung MT Pos.6 (KR-K1304 Einfahrt Block 1.3.3)", + "role": "sensorPinQuery", + "unit": "K1304", + "cabinet": "UC2303", + "pos": [ + 225264.8, + 248869.6 + ] + }, + { + "id": "BG4334", + "constant": "cInBG4334", + "hwAddress": "%E433.4", + "comment": "in Separator (ILS-CV-M1309)", + "role": "sensorInSep", + "unit": "M1309", + "cabinet": "UC2303", + "pos": [ + 214566.0, + 247170.1 + ] + }, + { + "id": "BG4335", + "constant": "cInBG4335", + "hwAddress": "%E433.5", + "comment": "Stausensor (M1309)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 216340.5, + 247182.6 + ] + }, + { + "id": "BG4336", + "constant": "cInBG4336", + "hwAddress": "%E433.6", + "comment": "Sensor Förderer voll (ILS-CV M1309)", + "role": "sensorConvFull", + "unit": "M1309", + "cabinet": "UC2303", + "pos": [ + 217822.8, + 247179.6 + ] + }, + { + "id": "BG4337", + "constant": "cInBG4337", + "hwAddress": "%E433.7", + "comment": "in Separator 1 (Block 1.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 207511.0, + 248141.3 + ] + }, + { + "id": "BG4340", + "constant": "cInBG4340", + "hwAddress": "%E434.0", + "comment": "Stausensor 1 (KR-M1304)", + "role": "sensorJam", + "unit": "M1304", + "cabinet": "UC2303", + "pos": [ + 213419.1, + 248422.2 + ] + }, + { + "id": "BG4342", + "constant": "cInBG4342", + "hwAddress": "%E434.2", + "comment": "in Separator (ILS-CV M1309)", + "role": "sensorInSep", + "unit": "M1309", + "cabinet": "UC2303", + "pos": [ + 224215.4, + 397074.7 + ] + }, + { + "id": "BG4343", + "constant": "cInBG4343", + "hwAddress": "%E434.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1309)", + "role": "sensorFinger", + "unit": "M1309", + "cabinet": "UC2303", + "pos": [ + 223499.9, + 397074.5 + ] + }, + { + "id": "BG4344", + "constant": "cInBG4344", + "hwAddress": "%E434.4", + "comment": "MT in Position (ILS-CV M1309)", + "role": "sensorCarrInPos", + "unit": "M1309", + "cabinet": "UC2303", + "pos": [ + 222730.4, + 397074.7 + ] + }, + { + "id": "BG4350", + "constant": "cInBG4350", + "hwAddress": "%E435.0", + "comment": "Stausensor Str.1 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 208400.0, + 250204.6 + ] + }, + { + "id": "BG4351", + "constant": "cInBG4351", + "hwAddress": "%E435.1", + "comment": "Stausensor Str.2 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 209200.0, + 250204.6 + ] + }, + { + "id": "BG4352", + "constant": "cInBG4352", + "hwAddress": "%E435.2", + "comment": "Stausensor Str.3 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 210000.0, + 250204.6 + ] + }, + { + "id": "BG4353", + "constant": "cInBG4353", + "hwAddress": "%E435.3", + "comment": "Stausensor Str.4 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 211146.1, + 250204.5 + ] + }, + { + "id": "BG4354", + "constant": "cInBG4354", + "hwAddress": "%E435.4", + "comment": "Stausensor Str.5 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 211946.1, + 250204.5 + ] + }, + { + "id": "BG4355", + "constant": "cInBG4355", + "hwAddress": "%E435.5", + "comment": "Stausensor Str.6 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 212746.1, + 250204.6 + ] + }, + { + "id": "BG4356", + "constant": "cInBG4356", + "hwAddress": "%E435.6", + "comment": "Stausensor Str.7 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 213545.3, + 250204.5 + ] + }, + { + "id": "BG4357", + "constant": "cInBG4357", + "hwAddress": "%E435.7", + "comment": "Stausensor Str.8 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 214346.1, + 250204.5 + ] + }, + { + "id": "BG4360", + "constant": "cInBG4360", + "hwAddress": "%E436.0", + "comment": "Stausensor Str.9 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 215146.1, + 250205.3 + ] + }, + { + "id": "BG4361", + "constant": "cInBG4361", + "hwAddress": "%E436.1", + "comment": "Stausensor Str.10 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 217150.0, + 250204.3 + ] + }, + { + "id": "BG4362", + "constant": "cInBG4362", + "hwAddress": "%E436.2", + "comment": "Stausensor Str.11 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 217950.0, + 250204.3 + ] + }, + { + "id": "BG4363", + "constant": "cInBG4363", + "hwAddress": "%E436.3", + "comment": "Stausensor Str.12 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 218750.0, + 250204.3 + ] + }, + { + "id": "BG4364", + "constant": "cInBG4364", + "hwAddress": "%E436.4", + "comment": "Stausensor Str.13 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 219549.1, + 250204.3 + ] + }, + { + "id": "BG4365", + "constant": "cInBG4365", + "hwAddress": "%E436.5", + "comment": "Stausensor Str.14 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 220350.0, + 250204.3 + ] + }, + { + "id": "BG4366", + "constant": "cInBG4366", + "hwAddress": "%E436.6", + "comment": "Stausensor Str.15 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 221150.0, + 250204.3 + ] + }, + { + "id": "BG4367", + "constant": "cInBG4367", + "hwAddress": "%E436.7", + "comment": "Stausensor Str.16 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 221950.0, + 250204.3 + ] + }, + { + "id": "BG4370", + "constant": "cInBG4370", + "hwAddress": "%E437.0", + "comment": "Stausensor Str.17 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 223150.0, + 250204.3 + ] + }, + { + "id": "BG4371", + "constant": "cInBG4371", + "hwAddress": "%E437.1", + "comment": "Stausensor Str.18 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 223950.0, + 250204.3 + ] + }, + { + "id": "BG4372", + "constant": "cInBG4372", + "hwAddress": "%E437.2", + "comment": "Stausensor Str.19 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 224748.4, + 250204.3 + ] + }, + { + "id": "BG4373", + "constant": "cInBG4373", + "hwAddress": "%E437.3", + "comment": "Stausensor Str.20 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 225550.0, + 250204.3 + ] + }, + { + "id": "BG4374", + "constant": "cInBG4374", + "hwAddress": "%E437.4", + "comment": "Stausensor Str.21 (Block 1.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2303", + "pos": [ + 226292.5, + 250204.3 + ] + }, + { + "id": "BG4375", + "constant": "cInBG4375", + "hwAddress": "%E437.5", + "comment": "Stausensor MT vor Pinband (KR-K1304) Block 1.3.3)", + "role": "sensorJam", + "unit": "K1304", + "cabinet": null, + "pos": null + }, + { + "id": "BG4380", + "constant": "cInBG4380", + "hwAddress": "%E438.0", + "comment": "in Separator 2 (Block 1.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 227459.1, + 248874.9 + ] + }, + { + "id": "BG4381", + "constant": "cInBG4381", + "hwAddress": "%E438.1", + "comment": "Pin Abfrage (KR-M1304) Block 1.3.4", + "role": "sensorPinQuery", + "unit": "M1304", + "cabinet": "UC2304", + "pos": [ + 228171.0, + 250128.3 + ] + }, + { + "id": "BG4382", + "constant": "cInBG4382", + "hwAddress": "%E438.2", + "comment": "Prüfung MT Pos.1 (KR-K1304 Einfahrt Block 1.3.4)", + "role": "sensorPinQuery", + "unit": "K1304", + "cabinet": "UC2304", + "pos": [ + 228296.5, + 249808.7 + ] + }, + { + "id": "BG4383", + "constant": "cInBG4383", + "hwAddress": "%E438.3", + "comment": "Stausensor (KR-M1304)", + "role": "sensorJam", + "unit": "M1304", + "cabinet": "UC2304", + "pos": [ + 227404.4, + 250128.5 + ] + }, + { + "id": "BG4384", + "constant": "cInBG4384", + "hwAddress": "%E438.4", + "comment": "in Separator 1 (ILS-CV M1308)", + "role": "sensorInSep", + "unit": "M1308", + "cabinet": "UC2304", + "pos": [ + 227404.1, + 250425.6 + ] + }, + { + "id": "BG4385", + "constant": "cInBG4385", + "hwAddress": "%E438.5", + "comment": "Stausensor Str.1 (ILS-CV M1308)", + "role": "sensorJam", + "unit": "M1308", + "cabinet": "UC2304", + "pos": [ + 227404.4, + 251000.0 + ] + }, + { + "id": "BG4386", + "constant": "cInBG4386", + "hwAddress": "%E438.6", + "comment": "Sensor Förderer voll (ILS-CV M1308)", + "role": "sensorConvFull", + "unit": "M1308", + "cabinet": "UC2304", + "pos": [ + 227404.6, + 251604.1 + ] + }, + { + "id": "BG4387", + "constant": "cInBG4387", + "hwAddress": "%E438.7", + "comment": "Prüfung MT Pos.2 (KR-K1304 Einfahrt Block 1.3.4)", + "role": "sensorPinQuery", + "unit": "K1304", + "cabinet": "UC2304", + "pos": [ + 231954.5, + 248849.9 + ] + }, + { + "id": "BG4390", + "constant": "cInBG4390", + "hwAddress": "%E439.0", + "comment": "Prüfung MT Pos.3 (KR-K1304 Einfahrt Block 1.3.4)", + "role": "sensorPinQuery", + "unit": "K1304", + "cabinet": "UC2304", + "pos": [ + 235309.9, + 248847.2 + ] + }, + { + "id": "BG4391", + "constant": "cInBG4391", + "hwAddress": "%E439.1", + "comment": "Prüfung MT Pos.4 (KR-K1304 Einfahrt Block 1.3.4)", + "role": "sensorPinQuery", + "unit": "K1304", + "cabinet": "UC2304", + "pos": [ + 238336.8, + 248849.9 + ] + }, + { + "id": "BG4410", + "constant": "cInBG4410", + "hwAddress": "%E441.0", + "comment": "Stausensor Str.1 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 229150.0, + 250204.6 + ] + }, + { + "id": "BG4411", + "constant": "cInBG4411", + "hwAddress": "%E441.1", + "comment": "Stausensor Str.2 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 229950.0, + 250204.6 + ] + }, + { + "id": "BG4412", + "constant": "cInBG4412", + "hwAddress": "%E441.2", + "comment": "Stausensor Str.3 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 230750.0, + 250204.6 + ] + }, + { + "id": "BG4413", + "constant": "cInBG4413", + "hwAddress": "%E441.3", + "comment": "Stausensor Str.4 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 231550.0, + 250201.3 + ] + }, + { + "id": "BG4414", + "constant": "cInBG4414", + "hwAddress": "%E441.4", + "comment": "Stausensor Str.5 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 232350.0, + 250201.3 + ] + }, + { + "id": "BG4415", + "constant": "cInBG4415", + "hwAddress": "%E441.5", + "comment": "Stausensor Str.6 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 233150.0, + 250201.4 + ] + }, + { + "id": "BG4416", + "constant": "cInBG4416", + "hwAddress": "%E441.6", + "comment": "Stausensor Str.7 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 233949.1, + 250201.3 + ] + }, + { + "id": "BG4417", + "constant": "cInBG4417", + "hwAddress": "%E441.7", + "comment": "Stausensor Str.8 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 235150.0, + 250201.3 + ] + }, + { + "id": "BG4420", + "constant": "cInBG4420", + "hwAddress": "%E442.0", + "comment": "Stausensor Str.9 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 235950.0, + 250202.1 + ] + }, + { + "id": "BG4421", + "constant": "cInBG4421", + "hwAddress": "%E442.1", + "comment": "Stausensor Str.10 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 236750.0, + 250204.3 + ] + }, + { + "id": "BG4422", + "constant": "cInBG4422", + "hwAddress": "%E442.2", + "comment": "Stausensor Str.11 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 237550.0, + 250204.3 + ] + }, + { + "id": "BG4423", + "constant": "cInBG4423", + "hwAddress": "%E442.3", + "comment": "Stausensor Str.12 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 238350.0, + 250204.3 + ] + }, + { + "id": "BG4424", + "constant": "cInBG4424", + "hwAddress": "%E442.4", + "comment": "Stausensor Str.13 (Block 1.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC2304", + "pos": [ + 239149.1, + 250204.3 + ] + }, + { + "id": "BG4440", + "constant": "cInBG4440", + "hwAddress": "%E444.0", + "comment": "in Separator 2 (KR-M1100)", + "role": "sensorInSep", + "unit": "M1100", + "cabinet": "UC0209", + "pos": [ + 242124.4, + 299526.8 + ] + }, + { + "id": "BG4442", + "constant": "cInBG4442", + "hwAddress": "%E444.2", + "comment": "Stausensor (ILS-KR M1100)", + "role": "sensorJam", + "unit": "M1100", + "cabinet": "UC0209", + "pos": [ + 242116.8, + 300434.5 + ] + }, + { + "id": "BG4443", + "constant": "cInBG4443", + "hwAddress": "%E444.3", + "comment": "Stausensor 7 (ILS-KR M1100)", + "role": "sensorJam", + "unit": "M1100", + "cabinet": "UC0209", + "pos": [ + 242124.4, + 299238.0 + ] + }, + { + "id": "BG4444", + "constant": "cInBG4444", + "hwAddress": "%E444.4", + "comment": "Stausensor (ILS-CV M0520)", + "role": "sensorJam", + "unit": "M0520", + "cabinet": "UC0209", + "pos": [ + 241877.4, + 301022.7 + ] + }, + { + "id": "BG4445", + "constant": "cInBG4445", + "hwAddress": "%E444.5", + "comment": "in Separator 1 (ILS-CV M1401)", + "role": "sensorInSep", + "unit": "M1401", + "cabinet": "UC0209", + "pos": [ + 241231.0, + 297635.9 + ] + }, + { + "id": "BG4446", + "constant": "cInBG4446", + "hwAddress": "%E444.6", + "comment": "Sensor Förderer voll (ILS-CV M1401)", + "role": "sensorConvFull", + "unit": "M1401", + "cabinet": "UC0209", + "pos": [ + 241231.0, + 296483.4 + ] + }, + { + "id": "BG4447", + "constant": "cInBG4447", + "hwAddress": "%E444.7", + "comment": "Stausensor (ILS-CV M1401)", + "role": "sensorJam", + "unit": "M1401", + "cabinet": "UC0209", + "pos": [ + 241231.0, + 297103.0 + ] + }, + { + "id": "BG4451", + "constant": "cInBG4451", + "hwAddress": "%E445.1", + "comment": "in Separator 3 (KR-M1100)", + "role": "sensorInSep", + "unit": "M1100", + "cabinet": "UC0209", + "pos": [ + 243550.4, + 297404.2 + ] + }, + { + "id": "BG4453", + "constant": "cInBG4453", + "hwAddress": "%E445.3", + "comment": "Stausensor 6 (ILS-KR M1100)", + "role": "sensorJam", + "unit": "M1100", + "cabinet": "UC0209", + "pos": [ + 243551.7, + 298794.7 + ] + }, + { + "id": "BG4454", + "constant": "cInBG4454", + "hwAddress": "%E445.4", + "comment": "Stausensor 8 (ILS-KR M1100)", + "role": "sensorJam", + "unit": "M1100", + "cabinet": "UC0209", + "pos": [ + 243464.9, + 301342.1 + ] + }, + { + "id": "BG4455", + "constant": "cInBG4455", + "hwAddress": "%E445.5", + "comment": "Stausensor (ILS-CV M0510)", + "role": "sensorJam", + "unit": "M0510", + "cabinet": "UC0209", + "pos": [ + 243464.9, + 302133.5 + ] + }, + { + "id": "BG4456", + "constant": "cInBG4456", + "hwAddress": "%E445.6", + "comment": "in Separator 4 (KR-M1100)", + "role": "sensorInSep", + "unit": "M1100", + "cabinet": null, + "pos": null + }, + { + "id": "BG4457", + "constant": "cInBG4457", + "hwAddress": "%E445.7", + "comment": "Stausensor nach Separator MB4456 (ILS-KR M1100)", + "role": "sensorJam", + "unit": "M1100", + "cabinet": null, + "pos": null + }, + { + "id": "BG4460", + "constant": "cInBG4460", + "hwAddress": "%E446.0", + "comment": "in Separator 2 (ILS-CV M1401)", + "role": "sensorInSep", + "unit": "M1401", + "cabinet": "UC0209", + "pos": [ + 241057.8, + 442762.3 + ] + }, + { + "id": "BG4461", + "constant": "cInBG4461", + "hwAddress": "%E446.1", + "comment": "MT in Position (ILS-CV M1401)", + "role": "sensorCarrInPos", + "unit": "M1401", + "cabinet": "UC0209", + "pos": [ + 241057.8, + 443572.3 + ] + }, + { + "id": "BG4462", + "constant": "cInBG4462", + "hwAddress": "%E446.2", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1401)", + "role": "sensorFinger", + "unit": "M1401", + "cabinet": "UC0209", + "pos": [ + 241060.5, + 443305.7 + ] + }, + { + "id": "BG4500", + "constant": "cInBG4500", + "hwAddress": "%E450.0", + "comment": "in Separator (ILS-CV M1100)", + "role": "sensorInSep", + "unit": "M1100", + "cabinet": "UC0210", + "pos": [ + 244407.9, + 289658.4 + ] + }, + { + "id": "BG4502", + "constant": "cInBG4502", + "hwAddress": "%E450.2", + "comment": "Stausensor 10 (KR-M1100)", + "role": "sensorJam", + "unit": "M1100", + "cabinet": "UC0210", + "pos": [ + 242272.2, + 288880.9 + ] + }, + { + "id": "BG4503", + "constant": "cInBG4503", + "hwAddress": "%E450.3", + "comment": "Stausensor 11 (KR-M1100)", + "role": "sensorJam", + "unit": "M1100", + "cabinet": null, + "pos": null + }, + { + "id": "BG4504", + "constant": "cInBG4504", + "hwAddress": "%E450.4", + "comment": "Stausensor 12 (KR-M1100)", + "role": "sensorJam", + "unit": "M1100", + "cabinet": null, + "pos": null + }, + { + "id": "BG4505", + "constant": "cInBG4505", + "hwAddress": "%E450.5", + "comment": "in Separator 3 (KR-M1100)", + "role": "sensorInSep", + "unit": "M1100", + "cabinet": "UC0210", + "pos": [ + 244473.8, + 280031.6 + ] + }, + { + "id": "BG4507", + "constant": "cInBG4507", + "hwAddress": "%E450.7", + "comment": "Stausensor 2 (KR-M1100)", + "role": "sensorJam", + "unit": "M1100", + "cabinet": "UC0210", + "pos": [ + 243229.6, + 280396.8 + ] + }, + { + "id": "BG4510", + "constant": "cInBG4510", + "hwAddress": "%E451.0", + "comment": "Rad dreht (KR-M1110)", + "role": "sensorWheel", + "unit": "M1110", + "cabinet": "UC0210", + "pos": [ + 244470.6, + 279014.9 + ] + }, + { + "id": "BG4512", + "constant": "cInBG4512", + "hwAddress": "%E451.2", + "comment": "in Separator (KR-M1100)", + "role": "sensorInSep", + "unit": "M1100", + "cabinet": "UC0210", + "pos": [ + 244470.6, + 281131.5 + ] + }, + { + "id": "BG4514", + "constant": "cInBG4514", + "hwAddress": "%E451.4", + "comment": "Stausensor 4 (CV-M1100)", + "role": "sensorJam", + "unit": "M1100", + "cabinet": "UC0210", + "pos": [ + 242075.2, + 282938.1 + ] + }, + { + "id": "BG4520", + "constant": "cInBG4520", + "hwAddress": "%E452.0", + "comment": "Sensor Förderer voll (CV-M1501)", + "role": "sensorConvFull", + "unit": "M1501", + "cabinet": "UC0210", + "pos": [ + 240322.6, + 277460.8 + ] + }, + { + "id": "BG4521", + "constant": "cInBG4521", + "hwAddress": "%E452.1", + "comment": "Stausensor (M1501)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0210", + "pos": [ + 240313.2, + 278336.0 + ] + }, + { + "id": "BG4522", + "constant": "cInBG4522", + "hwAddress": "%E452.2", + "comment": "in Separator (CV-M1501)", + "role": "sensorInSep", + "unit": "M1501", + "cabinet": "UC0210", + "pos": [ + 241503.5, + 281505.5 + ] + }, + { + "id": "BG4524", + "constant": "cInBG4524", + "hwAddress": "%E452.4", + "comment": "Sensor Förderer voll (CV-M1601)", + "role": "sensorConvFull", + "unit": "M1601", + "cabinet": "UC0210", + "pos": [ + 242990.9, + 277686.3 + ] + }, + { + "id": "BG4525", + "constant": "cInBG4525", + "hwAddress": "%E452.5", + "comment": "Stausensor (CV-M1601)", + "role": "sensorJam", + "unit": "M1601", + "cabinet": "UC0210", + "pos": [ + 242997.3, + 278385.7 + ] + }, + { + "id": "BG4526", + "constant": "cInBG4526", + "hwAddress": "%E452.6", + "comment": "in Separator (CV-M1601)", + "role": "sensorInSep", + "unit": "M1601", + "cabinet": "UC0210", + "pos": [ + 242997.3, + 278674.6 + ] + }, + { + "id": "BG4530", + "constant": "cInBG4530", + "hwAddress": "%E453.0", + "comment": "in Separator (ILS-CV M4701)", + "role": "sensorInSep", + "unit": "M4701", + "cabinet": "UC0210", + "pos": [ + 244403.6, + 288741.1 + ] + }, + { + "id": "BG4531", + "constant": "cInBG4531", + "hwAddress": "%E453.1", + "comment": "Abfrage Mitnehmerfinger in Position (CV M4701)", + "role": "sensorFinger", + "unit": "M4701", + "cabinet": "UC0211", + "pos": [ + 245185.3, + 288747.6 + ] + }, + { + "id": "BG4532", + "constant": "cInBG4532", + "hwAddress": "%E453.2", + "comment": "Stausensor (CV-M4701)", + "role": "sensorJam", + "unit": "M4701", + "cabinet": "UC0210", + "pos": [ + 244623.7, + 287826.5 + ] + }, + { + "id": "BG4533", + "constant": "cInBG4533", + "hwAddress": "%E453.3", + "comment": "MT in Position (ILS-CV M4701)", + "role": "sensorCarrInPos", + "unit": "M4701", + "cabinet": "UC0211", + "pos": [ + 245925.1, + 288744.2 + ] + }, + { + "id": "BG4534", + "constant": "cInBG4534", + "hwAddress": "%E453.4", + "comment": "Stausensor (ILS-CV M1801)", + "role": "sensorJam", + "unit": "M1801", + "cabinet": null, + "pos": null + }, + { + "id": "BG4535", + "constant": "cInBG4535", + "hwAddress": "%E453.5", + "comment": "in Separator (ILS-CV M1801)", + "role": "sensorInSep", + "unit": "M1801", + "cabinet": "UC0210", + "pos": [ + 250894.7, + 296853.9 + ] + }, + { + "id": "BG4536", + "constant": "cInBG4536", + "hwAddress": "%E453.6", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1801)", + "role": "sensorJam", + "unit": "M1801", + "cabinet": "UC0210", + "pos": [ + 250152.2, + 296853.9 + ] + }, + { + "id": "BG4537", + "constant": "cInBG4537", + "hwAddress": "%E453.7", + "comment": "MT in Position (ILS-CV M1801)", + "role": "sensorConvFull", + "unit": "M1801", + "cabinet": "UC0210", + "pos": [ + 249412.4, + 296857.3 + ] + }, + { + "id": "BG4540", + "constant": "cInBG4540", + "hwAddress": "%E454.0", + "comment": "in Separator 2 (ILS-CV M1401)", + "role": "sensorInSep", + "unit": "M1401", + "cabinet": "UC0210", + "pos": [ + 240343.6, + 423437.5 + ] + }, + { + "id": "BG4541", + "constant": "cInBG4541", + "hwAddress": "%E454.1", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1501)", + "role": "sensorFinger", + "unit": "M1501", + "cabinet": "UC0210", + "pos": [ + 240356.2, + 424341.8 + ] + }, + { + "id": "BG4542", + "constant": "cInBG4542", + "hwAddress": "%E454.2", + "comment": "MT in Position (ILS-CV M1501)", + "role": "sensorCarrInPos", + "unit": "M1501", + "cabinet": "UC0210", + "pos": [ + 240353.5, + 424608.4 + ] + }, + { + "id": "BG4543", + "constant": "cInBG4543", + "hwAddress": "%E454.3", + "comment": "in Separator 2 (ILS-CV M1401)", + "role": "sensorInSep", + "unit": "M1401", + "cabinet": "UC0210", + "pos": [ + 242660.5, + 419880.2 + ] + }, + { + "id": "BG4544", + "constant": "cInBG4544", + "hwAddress": "%E454.4", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M1601)", + "role": "sensorFinger", + "unit": "M1601", + "cabinet": "UC0210", + "pos": [ + 242674.9, + 420778.8 + ] + }, + { + "id": "BG4545", + "constant": "cInBG4545", + "hwAddress": "%E454.5", + "comment": "MT in Position (ILS-CV M1601)", + "role": "sensorCarrInPos", + "unit": "M1601", + "cabinet": "UC0210", + "pos": [ + 242672.2, + 421045.3 + ] + }, + { + "id": "BG4550", + "constant": "cInBG4550", + "hwAddress": "%E455.0", + "comment": "Sensor Förderer voll (ILS-CV M1801)", + "role": "sensorConvFull", + "unit": "M1801", + "cabinet": null, + "pos": null + }, + { + "id": "BG4551", + "constant": "cInBG4551", + "hwAddress": "%E455.1", + "comment": "Stausensor(ILS-CV M1801)", + "role": "sensorJam", + "unit": "M1801", + "cabinet": null, + "pos": null + }, + { + "id": "BG4552", + "constant": "cInBG4552", + "hwAddress": "%E455.2", + "comment": "in Separator (ILS-CV M1801)", + "role": "sensorInSep", + "unit": "M1801", + "cabinet": null, + "pos": null + }, + { + "id": "BG4553", + "constant": "cInBG4553", + "hwAddress": "%E455.3", + "comment": "Sensor Förderer voll (ILS-CV 4701)", + "role": "sensorConvFull", + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG4554", + "constant": "cInBG4554", + "hwAddress": "%E455.4", + "comment": "Stausensor(ILS-CV M4701)", + "role": "sensorJam", + "unit": "M4701", + "cabinet": null, + "pos": null + }, + { + "id": "BG4555", + "constant": "cInBG4555", + "hwAddress": "%E455.5", + "comment": "in Separator (ILS-CV M4701)", + "role": "sensorInSep", + "unit": "M4701", + "cabinet": null, + "pos": null + } + ], + "units": [ + { + "unit": "K1101", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.1.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.1.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC2101", + "pos": [ + 186658.6, + 309134.2 + ], + "io": { + "sensorPinQuery": [ + "BG3002", + "BG3007", + "BG3010", + "BG3011", + "BG3012", + "BG3062", + "BG3067", + "BG3070", + "BG3071", + "BG3072" + ], + "sensorJam": [ + "BG3065" + ] + }, + "signalCount": 11 + }, + { + "unit": "K1102", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.1.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.1.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC2103", + "pos": [ + 207628.8, + 309134.2 + ], + "io": { + "sensorPinQuery": [ + "BG3122", + "BG3127", + "BG3130", + "BG3131", + "BG3132", + "BG3133", + "BG3182", + "BG3187", + "BG3190", + "BG3191" + ], + "sensorJam": [ + "BG3125", + "BG3185" + ] + }, + "signalCount": 12 + }, + { + "unit": "K1201", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.2.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.2.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0205", + "pos": [ + 186578.7, + 288134.2 + ], + "io": { + "sensorPinQuery": [ + "BG3482", + "BG3487", + "BG3490", + "BG3491", + "BG3492", + "BG3542", + "BG3547", + "BG3550", + "BG3551", + "BG3552" + ], + "sensorJam": [ + "BG3553" + ] + }, + "signalCount": 11 + }, + { + "unit": "K1202", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.2.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.2.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0207", + "pos": [ + 207629.1, + 288128.1 + ], + "io": { + "sensorPinQuery": [ + "BG3602", + "BG3607", + "BG3610", + "BG3611", + "BG3612", + "BG3613", + "BG3662", + "BG3667", + "BG3670", + "BG3671" + ] + }, + "signalCount": 10 + }, + { + "unit": "K1203", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [ + { + "id": "Block 1.2.3", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0207", + "pos": [ + 226369.5, + 287829.1 + ], + "io": { + "sensorJam": [ + "BG3625" + ] + }, + "signalCount": 1 + }, + { + "unit": "K1207", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0207", + "pos": [ + 206612.9, + 285852.1 + ], + "io": { + "sensorJam": [ + "BG3605" + ] + }, + "signalCount": 1 + }, + { + "unit": "K1303", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.3.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.3.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC2301", + "pos": [ + 186359.6, + 249824.2 + ], + "io": { + "sensorPinQuery": [ + "BG4202", + "BG4207", + "BG4210", + "BG4211", + "BG4212", + "BG4262", + "BG4267", + "BG4270", + "BG4271", + "BG4272" + ], + "sensorJam": [ + "BG4273" + ] + }, + "signalCount": 11 + }, + { + "unit": "K1304", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.3.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.3.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC2303", + "pos": [ + 207454.4, + 249808.7 + ], + "io": { + "sensorPinQuery": [ + "BG4322", + "BG4327", + "BG4330", + "BG4331", + "BG4332", + "BG4333", + "BG4382", + "BG4387", + "BG4390", + "BG4391" + ], + "sensorJam": [ + "BG4375" + ] + }, + "signalCount": 11 + }, + { + "unit": "K1305", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC2301", + "pos": [ + 187034.8, + 250991.5 + ], + "io": { + "sensorJam": [ + "BG4205" + ] + }, + "signalCount": 1 + }, + { + "unit": "M0510", + "unitKind": "CV", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0209", + "pos": [ + 243464.9, + 302133.5 + ], + "io": { + "sensorJam": [ + "BG4455" + ] + }, + "signalCount": 1 + }, + { + "unit": "M0520", + "unitKind": "CV", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0209", + "pos": [ + 241877.4, + 301022.7 + ], + "io": { + "sensorJam": [ + "BG4444" + ] + }, + "signalCount": 1 + }, + { + "unit": "M0701", + "unitKind": "CV", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0209", + "pos": [ + 243464.9, + 301822.0 + ], + "io": { + "switchOutput": [ + "MB4455" + ] + }, + "signalCount": 1 + }, + { + "unit": "M0801", + "unitKind": "CV", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0209", + "pos": [ + 241877.4, + 300752.7 + ], + "io": { + "switchOutput": [ + "MB4444" + ] + }, + "signalCount": 1 + }, + { + "unit": "M1100", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC0209", + "pos": [ + 242124.4, + 299526.8 + ], + "io": { + "sensorInSep": [ + "BG4440", + "BG4451", + "BG4456", + "BG4500", + "BG4505", + "BG4512" + ], + "sensorJam": [ + "BG4442", + "BG4443", + "BG4453", + "BG4454", + "BG4457", + "BG4502", + "BG4503", + "BG4504", + "BG4507", + "BG4514" + ], + "stopperOutput": [ + "MB4440", + "MB4451", + "MB4456", + "MB4500", + "MB4505" + ] + }, + "signalCount": 21 + }, + { + "unit": "M1101", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.1.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.1.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC021", + "pos": [ + 252874.1, + 306685.8 + ], + "io": { + "motorProtection": [ + "FC0140" + ], + "sensorPinQuery": [ + "BG3001", + "BG3061" + ], + "sensorJam": [ + "BG3003", + "BG3063", + "BG3073" + ], + "motorOutput": [ + "MA0140" + ] + }, + "signalCount": 7 + }, + { + "unit": "M1102", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.1.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.1.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC021", + "pos": [ + 252874.1, + 306415.8 + ], + "io": { + "motorProtection": [ + "FC0141" + ], + "sensorPinQuery": [ + "BG3121", + "BG3181" + ], + "sensorJam": [ + "BG3123", + "BG3141", + "BG3142" + ], + "motorOutput": [ + "MA0141" + ] + }, + "signalCount": 7 + }, + { + "unit": "M1103", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC0201", + "pos": [ + 252775.2, + 275540.0 + ], + "io": { + "motorProtection": [ + "FC0060" + ], + "sensorJam": [ + "BG3242", + "BG3302", + "BG3305" + ], + "sensorInSep": [ + "BG3245" + ], + "sensorWheel": [ + "BG3306" + ], + "motorOutput": [ + "MA0060" + ], + "stopperOutput": [ + "MB3245" + ] + }, + "signalCount": 8 + }, + { + "unit": "M1104", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC0203", + "pos": [ + 252775.2, + 275270.0 + ], + "io": { + "motorProtection": [ + "FC0061" + ], + "sensorJam": [ + "BG3362", + "BG3365", + "BG3422", + "BG3426" + ], + "sensorInSep": [ + "BG3425" + ], + "sensorWheel": [ + "BG3433" + ], + "motorOutput": [ + "MA0061" + ], + "stopperOutput": [ + "MB3425" + ] + }, + "signalCount": 9 + }, + { + "unit": "M1105", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0201", + "pos": [ + 252874.1, + 306145.8 + ], + "io": { + "motorProtection": [ + "FC0142" + ], + "sensorInSep": [ + "BG3000", + "BG3004", + "BG3244" + ], + "sensorJam": [ + "BG3005", + "BG3241" + ], + "sensorConvFull": [ + "BG3006" + ], + "sensorFinger": [ + "BG3243" + ], + "sensorCarrInPos": [ + "BG3247" + ], + "motorOutput": [ + "MA0142" + ], + "stopperOutput": [ + "MB3000", + "MB3004", + "MB3244" + ], + "switchOutput": [ + "MB3241" + ] + }, + "signalCount": 14 + }, + { + "unit": "M1106", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "Block 1.1.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0202", + "pos": [ + 252874.1, + 305875.8 + ], + "io": { + "motorProtection": [ + "FC0143" + ], + "sensorInSep": [ + "BG3060", + "BG3064", + "BG3304" + ], + "sensorConvFull": [ + "BG3066" + ], + "sensorJam": [ + "BG3301" + ], + "sensorCarrInPos": [ + "BG3307" + ], + "motorOutput": [ + "MA0143" + ], + "stopperOutput": [ + "MB3060", + "MB3064", + "MB3304" + ] + }, + "signalCount": 11 + }, + { + "unit": "M1107", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0203", + "pos": [ + 254787.2, + 306685.8 + ], + "io": { + "motorProtection": [ + "FC0144" + ], + "sensorJam": [ + "BG3361" + ], + "sensorFinger": [ + "BG3363" + ], + "sensorInSep": [ + "BG3364" + ], + "sensorCarrInPos": [ + "BG3367" + ], + "motorOutput": [ + "MA0144" + ], + "stopperOutput": [ + "MB3364" + ] + }, + "signalCount": 7 + }, + { + "unit": "M1108", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "Block 1.1.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0204", + "pos": [ + 254787.2, + 306415.8 + ], + "io": { + "motorProtection": [ + "FC0145" + ], + "sensorJam": [ + "BG3421" + ], + "sensorFinger": [ + "BG3423" + ], + "sensorInSep": [ + "BG3424" + ], + "sensorCarrInPos": [ + "BG3427" + ], + "motorOutput": [ + "MA0145" + ], + "switchOutput": [ + "MB3421" + ], + "stopperOutput": [ + "MB3424" + ] + }, + "signalCount": 8 + }, + { + "unit": "M1109", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC021", + "pos": [ + 254787.2, + 306145.8 + ], + "io": { + "motorProtection": [ + "FC0146" + ], + "sensorConvFull": [ + "BG3136" + ], + "sensorInSep": [ + "BG3143" + ], + "sensorFinger": [ + "BG3144" + ], + "sensorCarrInPos": [ + "BG3145" + ], + "motorOutput": [ + "MA0146" + ], + "stopperOutput": [ + "MB3143" + ] + }, + "signalCount": 7 + }, + { + "unit": "M1110", + "unitKind": "KR", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": "UC0210", + "pos": [ + 255437.7, + 274190.0 + ], + "io": { + "motorProtection": [ + "FC0075" + ], + "sensorWheel": [ + "BG4510" + ], + "motorOutput": [ + "MA0075" + ] + }, + "signalCount": 3 + }, + { + "unit": "M1201", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.2.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.2.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0205", + "pos": [ + 252775.2, + 275000.0 + ], + "io": { + "motorProtection": [ + "FC0062" + ], + "sensorPinQuery": [ + "BG3481", + "BG3541" + ], + "sensorJam": [ + "BG3483", + "BG3543" + ], + "motorOutput": [ + "MA0062" + ] + }, + "signalCount": 6 + }, + { + "unit": "M1202", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.2.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.2.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0207", + "pos": [ + 252775.2, + 274730.0 + ], + "io": { + "motorProtection": [ + "FC0063" + ], + "sensorPinQuery": [ + "BG3601", + "BG3661" + ], + "sensorJam": [ + "BG3603", + "BG3621" + ], + "motorOutput": [ + "MA0063" + ] + }, + "signalCount": 6 + }, + { + "unit": "M1203", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC022", + "pos": [ + 252669.5, + 262747.3 + ], + "io": { + "motorProtection": [ + "FC0200" + ], + "sensorJam": [ + "BG3722", + "BG3782", + "BG3785" + ], + "sensorInSep": [ + "BG3725" + ], + "sensorWheel": [ + "BG3786" + ], + "motorOutput": [ + "MA0200" + ], + "stopperOutput": [ + "MB3725" + ] + }, + "signalCount": 8 + }, + { + "unit": "M1204", + "unitKind": "KR", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": "UC022", + "pos": [ + 252669.5, + 262477.3 + ], + "io": { + "motorProtection": [ + "FC0201" + ], + "sensorJam": [ + "BG3842", + "BG3845", + "BG3902", + "BG3912" + ], + "sensorWheel": [ + "BG3911" + ], + "motorOutput": [ + "MA0201" + ] + }, + "signalCount": 7 + }, + { + "unit": "M1205", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0205", + "pos": [ + 252775.2, + 274460.0 + ], + "io": { + "motorProtection": [ + "FC0064" + ], + "sensorInSep": [ + "BG3480", + "BG3484", + "BG3724" + ], + "sensorJam": [ + "BG3485", + "BG3721" + ], + "sensorConvFull": [ + "BG3486" + ], + "sensorFinger": [ + "BG3723" + ], + "sensorCarrInPos": [ + "BG3727" + ], + "motorOutput": [ + "MA0064" + ], + "stopperOutput": [ + "MB3480", + "MB3484", + "MB3724" + ] + }, + "signalCount": 13 + }, + { + "unit": "M1206", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0206", + "pos": [ + 252775.2, + 274190.0 + ], + "io": { + "motorProtection": [ + "FC0065" + ], + "sensorInSep": [ + "BG3540", + "BG3544", + "BG3784" + ], + "sensorJam": [ + "BG3545", + "BG3781" + ], + "sensorConvFull": [ + "BG3546" + ], + "sensorFinger": [ + "BG3783" + ], + "sensorCarrInPos": [ + "BG3787" + ], + "motorOutput": [ + "MA0065" + ], + "stopperOutput": [ + "MB3540", + "MB3544", + "MB3784" + ] + }, + "signalCount": 13 + }, + { + "unit": "M1207", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "Block 1.2.3", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0207", + "pos": [ + 252775.2, + 273920.0 + ], + "io": { + "motorProtection": [ + "FC0066" + ], + "sensorInSep": [ + "BG3604", + "BG3844" + ], + "sensorConvFull": [ + "BG3606" + ], + "sensorJam": [ + "BG3841" + ], + "sensorFinger": [ + "BG3843" + ], + "sensorCarrInPos": [ + "BG3847" + ], + "motorOutput": [ + "MA0066" + ], + "stopperOutput": [ + "MB3604", + "MB3844" + ] + }, + "signalCount": 10 + }, + { + "unit": "M1208", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0208", + "pos": [ + 252775.2, + 273650.0 + ], + "io": { + "motorProtection": [ + "FC0067" + ], + "sensorInSep": [ + "BG3660", + "BG3664", + "BG3904" + ], + "sensorJam": [ + "BG3665", + "BG3901" + ], + "sensorConvFull": [ + "BG3666" + ], + "sensorFinger": [ + "BG3903" + ], + "sensorCarrInPos": [ + "BG3907" + ], + "motorOutput": [ + "MA0067" + ], + "stopperOutput": [ + "MB3660", + "MB3664", + "MB3904" + ], + "switchOutput": [ + "MB3901" + ] + }, + "signalCount": 14 + }, + { + "unit": "M1209", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0207", + "pos": [ + 255437.7, + 275540.0 + ], + "io": { + "motorProtection": [ + "FC0070" + ], + "sensorConvFull": [ + "BG3616" + ], + "sensorInSep": [ + "BG3622" + ], + "sensorFinger": [ + "BG3623" + ], + "sensorCarrInPos": [ + "BG3624" + ], + "motorOutput": [ + "MA0070" + ], + "stopperOutput": [ + "MB3622" + ] + }, + "signalCount": 7 + }, + { + "unit": "M1301", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC022", + "pos": [ + 252669.5, + 262207.3 + ], + "io": { + "motorProtection": [ + "FC0202" + ], + "sensorJam": [ + "BG3962", + "BG4022", + "BG4025" + ], + "sensorInSep": [ + "BG3965", + "BG4020" + ], + "sensorWheel": [ + "BG4026" + ], + "motorOutput": [ + "MA0202" + ], + "stopperOutput": [ + "MB3965", + "MB4020" + ] + }, + "signalCount": 10 + }, + { + "unit": "M1302", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC022", + "pos": [ + 252669.5, + 261937.3 + ], + "io": { + "motorProtection": [ + "FC0203" + ], + "sensorInSep": [ + "BG4080", + "BG4085" + ], + "sensorJam": [ + "BG4082", + "BG4090", + "BG4142" + ], + "sensorWheel": [ + "BG4150" + ], + "motorOutput": [ + "MA0203" + ], + "stopperOutput": [ + "MB4080", + "MB4085" + ] + }, + "signalCount": 10 + }, + { + "unit": "M1303", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.3.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.3.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC023", + "pos": [ + 252961.6, + 248448.5 + ], + "io": { + "motorProtection": [ + "FC0260" + ], + "sensorPinQuery": [ + "BG4201", + "BG4261" + ], + "sensorJam": [ + "BG4203", + "BG4263" + ], + "motorOutput": [ + "MA0260" + ] + }, + "signalCount": 6 + }, + { + "unit": "M1304", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 1.3.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.3.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC023", + "pos": [ + 252961.6, + 248178.5 + ], + "io": { + "motorProtection": [ + "FC0261" + ], + "sensorPinQuery": [ + "BG4321", + "BG4381" + ], + "sensorJam": [ + "BG4323", + "BG4340", + "BG4383" + ], + "motorOutput": [ + "MA0261" + ] + }, + "signalCount": 7 + }, + { + "unit": "M1305", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC023", + "pos": [ + 252961.6, + 247901.5 + ], + "io": { + "motorProtection": [ + "FC0262" + ], + "sensorInSep": [ + "BG3960", + "BG3964" + ], + "sensorJam": [ + "BG3961" + ], + "sensorFinger": [ + "BG3963" + ], + "sensorCarrInPos": [ + "BG3967" + ], + "motorOutput": [ + "MA0262" + ], + "stopperOutput": [ + "MB3960", + "MB3964" + ] + }, + "signalCount": 9 + }, + { + "unit": "M1306", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "Block 1.3.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC023", + "pos": [ + 252961.6, + 247635.1 + ], + "io": { + "motorProtection": [ + "FC0263" + ], + "sensorJam": [ + "BG4021", + "BG4265" + ], + "sensorFinger": [ + "BG4023" + ], + "sensorInSep": [ + "BG4024", + "BG4264" + ], + "sensorCarrInPos": [ + "BG4027" + ], + "sensorConvFull": [ + "BG4266" + ], + "motorOutput": [ + "MA0263" + ], + "stopperOutput": [ + "MB4024", + "MB4264" + ] + }, + "signalCount": 11 + }, + { + "unit": "M1307", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC023", + "pos": [ + 252961.6, + 247365.1 + ], + "io": { + "motorProtection": [ + "FC0264" + ], + "sensorJam": [ + "BG4081", + "BG4325" + ], + "sensorFinger": [ + "BG4083" + ], + "sensorInSep": [ + "BG4084", + "BG4324" + ], + "sensorCarrInPos": [ + "BG4087" + ], + "motorOutput": [ + "MA0264" + ], + "stopperOutput": [ + "MB4084", + "MB4324" + ] + }, + "signalCount": 10 + }, + { + "unit": "M1308", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC023", + "pos": [ + 252961.6, + 247095.1 + ], + "io": { + "motorProtection": [ + "FC0265" + ], + "sensorJam": [ + "BG4141", + "BG4385" + ], + "sensorFinger": [ + "BG4143" + ], + "sensorInSep": [ + "BG4144", + "BG4384" + ], + "sensorCarrInPos": [ + "BG4147" + ], + "sensorConvFull": [ + "BG4386" + ], + "motorOutput": [ + "MA0265" + ], + "stopperOutput": [ + "MB4144", + "MB4384" + ] + }, + "signalCount": 11 + }, + { + "unit": "M1309", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC023", + "pos": [ + 252961.6, + 246825.1 + ], + "io": { + "motorProtection": [ + "FC0266" + ], + "sensorInSep": [ + "BG4334", + "BG4342" + ], + "sensorConvFull": [ + "BG4336" + ], + "sensorFinger": [ + "BG4343" + ], + "sensorCarrInPos": [ + "BG4344" + ], + "motorOutput": [ + "MA0266" + ], + "stopperOutput": [ + "MB4342" + ] + }, + "signalCount": 8 + }, + { + "unit": "M1401", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0209", + "pos": [ + 255437.7, + 275270.0 + ], + "io": { + "motorProtection": [ + "FC0071" + ], + "sensorInSep": [ + "BG4445", + "BG4460", + "BG4540", + "BG4543" + ], + "sensorConvFull": [ + "BG4446" + ], + "sensorJam": [ + "BG4447" + ], + "sensorCarrInPos": [ + "BG4461" + ], + "sensorFinger": [ + "BG4462" + ], + "motorOutput": [ + "MA0071" + ], + "stopperOutput": [ + "MB4460" + ] + }, + "signalCount": 11 + }, + { + "unit": "M1501", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0210", + "pos": [ + 255437.7, + 275000.0 + ], + "io": { + "motorProtection": [ + "FC0072" + ], + "sensorConvFull": [ + "BG4520" + ], + "sensorInSep": [ + "BG4522" + ], + "sensorFinger": [ + "BG4541" + ], + "sensorCarrInPos": [ + "BG4542" + ], + "motorOutput": [ + "MA0072" + ], + "stopperOutput": [ + "MB4512", + "MB4522", + "MB4540" + ] + }, + "signalCount": 9 + }, + { + "unit": "M1601", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0210", + "pos": [ + 255447.1, + 274730.4 + ], + "io": { + "motorProtection": [ + "FC0073" + ], + "sensorConvFull": [ + "BG4524" + ], + "sensorJam": [ + "BG4525" + ], + "sensorInSep": [ + "BG4526" + ], + "sensorFinger": [ + "BG4544" + ], + "sensorCarrInPos": [ + "BG4545" + ], + "motorOutput": [ + "MA0073" + ], + "stopperOutput": [ + "MB4526", + "MB4543" + ] + }, + "signalCount": 9 + }, + { + "unit": "M1801", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC0210", + "pos": [ + 255437.7, + 273920.0 + ], + "io": { + "motorProtection": [ + "FC0076", + "FC0077" + ], + "sensorJam": [ + "BG4534", + "BG4536", + "BG4551" + ], + "sensorInSep": [ + "BG4535", + "BG4552" + ], + "sensorConvFull": [ + "BG4537", + "BG4550" + ], + "motorOutput": [ + "MA0076" + ], + "stopperOutput": [ + "MB4535" + ] + }, + "signalCount": 11 + }, + { + "unit": "M2309", + "unitKind": "CV", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC2207", + "pos": [ + 216481.1, + 267740.4 + ], + "io": { + "sensorJam": [ + "BG4091" + ], + "switchOutput": [ + "MB4086" + ] + }, + "signalCount": 2 + }, + { + "unit": "M4701", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0210", + "pos": [ + 255437.7, + 274460.0 + ], + "io": { + "motorProtection": [ + "FC0074" + ], + "sensorInSep": [ + "BG4530", + "BG4555" + ], + "sensorFinger": [ + "BG4531" + ], + "sensorJam": [ + "BG4532", + "BG4554" + ], + "sensorCarrInPos": [ + "BG4533" + ], + "motorOutput": [ + "MA0074" + ], + "stopperOutput": [ + "MB4530" + ] + }, + "signalCount": 9 + } + ], + "areas": [ + { + "id": "Block 1.1.1", + "kind": "pinStoreBlock", + "members": [ + "K1101", + "M1101" + ], + "cabinets": [ + "UC0201", + "UC2101" + ] + }, + { + "id": "Block 1.1.2", + "kind": "pinStoreBlock", + "members": [ + "K1101", + "M1101", + "M1106" + ], + "cabinets": [ + "UC0202", + "UC2101", + "UC2102" + ] + }, + { + "id": "Block 1.1.3", + "kind": "pinStoreBlock", + "members": [ + "K1102", + "M1102" + ], + "cabinets": [ + "UC0203", + "UC2103" + ] + }, + { + "id": "Block 1.1.4", + "kind": "pinStoreBlock", + "members": [ + "K1102", + "M1102", + "M1108" + ], + "cabinets": [ + "UC0204", + "UC2104" + ] + }, + { + "id": "Block 1.2.1", + "kind": "pinStoreBlock", + "members": [ + "K1201", + "M1201" + ], + "cabinets": [ + "UC0205", + "UC2201" + ] + }, + { + "id": "Block 1.2.2", + "kind": "pinStoreBlock", + "members": [ + "K1201", + "M1201" + ], + "cabinets": [ + "UC0206", + "UC2202" + ] + }, + { + "id": "Block 1.2.3", + "kind": "pinStoreBlock", + "members": [ + "K1202", + "K1203", + "M1202", + "M1207" + ], + "cabinets": [ + "UC0207", + "UC2203" + ] + }, + { + "id": "Block 1.2.4", + "kind": "pinStoreBlock", + "members": [ + "K1202", + "M1202" + ], + "cabinets": [ + "UC0208", + "UC2204" + ] + }, + { + "id": "Block 1.3.1", + "kind": "pinStoreBlock", + "members": [ + "K1303", + "M1303" + ], + "cabinets": [ + "UC2205", + "UC2301" + ] + }, + { + "id": "Block 1.3.2", + "kind": "pinStoreBlock", + "members": [ + "K1303", + "M1303", + "M1306" + ], + "cabinets": [ + "UC2206", + "UC2302" + ] + }, + { + "id": "Block 1.3.3", + "kind": "pinStoreBlock", + "members": [ + "K1304", + "M1304" + ], + "cabinets": [ + "UC2207", + "UC2303" + ] + }, + { + "id": "Block 1.3.4", + "kind": "pinStoreBlock", + "members": [ + "K1304", + "M1304" + ], + "cabinets": [ + "UC2208", + "UC2304" + ] + }, + { + "id": "UZ0201", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0202", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0203", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0204", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0205", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0206", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0207", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0208", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0209", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0210", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0211", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2101", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2102", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2103", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2104", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2201", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2202", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2203", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2204", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2205", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2206", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2207", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2208", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2301", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2302", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2303", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ2304", + "kind": "safetyZone", + "members": [], + "cabinets": [] + } + ], + "unassignedSignals": [ + "BP0004", + "BP0107", + "BP0167", + "BP0227", + "DI0005", + "DI0006", + "DI0007", + "DI0010", + "DI0011", + "DI0012", + "DI0013", + "DI0014", + "DI0015", + "DI0016", + "DI0021", + "DI0022", + "DI0023", + "DI0024", + "DI0025", + "DI0026", + "DI0034", + "DI0035", + "DI0036", + "DI0037", + "DI0100", + "DI0101", + "DI0102", + "DI0103", + "DI0106", + "DI0114", + "DI0160", + "DI0161", + "DI0162", + "DI0163", + "DI0164", + "DI0165", + "DI0166", + "DI0174", + "DI0220", + "DI0221", + "DI0222", + "DI0223", + "DI0226", + "DI0234", + "MB3061", + "MB3306", + "MB3541", + "MB3786", + "MB4026", + "MB4261", + "PF0000", + "PF0001", + "PF0002", + "PF0003", + "PF0004", + "PF0005", + "PF0006", + "PF0030", + "PF0031", + "PF0032", + "PF0033", + "PF0100", + "PF0101", + "PF0102", + "PF0117", + "PF0160", + "PF0161", + "PF0162", + "PF0177", + "PF0220", + "PF0221", + "PF0222", + "PF0237", + "QA0610", + "QA0611", + "QA0612", + "QA0613", + "QA0660", + "QA0661", + "QA0662", + "QA0663", + "QA0920", + "QA0921", + "QA0922", + "QA0923", + "QA1230", + "QA1231", + "QA1232", + "QA1233", + "QA1540", + "QA1541", + "QA1542", + "QA1543", + "SF0000", + "SF0001", + "SF0002", + "SF0003", + "SF0117", + "SF0177", + "SF0237", + "SF0400", + "SF0404", + "SF0541", + "SF0542", + "SF0545", + "SF0546", + "SF0710", + "SF0714", + "SF0781", + "SF0785", + "SF1020", + "SF1024", + "SF1091", + "SF1095", + "SF1330", + "SF1334", + "SF1401", + "SF1405" + ], + "todo": [ + "topology[] aus connect-Daten uebernommen — TRO-IDs den Einheiten (units[]) noch zuordnen", + "Timings, Priority, Release, customCode manuell pflegen" + ], + "topology": { + "format": "hmf-connect-v1", + "tros": [ + { + "id": "TRO200", + "fbType": "Vario", + "comment": "TRO 200 (Vario)", + "entries": [ + { + "jamArea": "JA1109_1", + "dbRef": "\"DB_JamArea1109\".stJam1109_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1109_2", + "dbRef": "\"DB_JamArea1109\".stJam1109_2", + "to": "TRO201", + "kind": "finger" + } + ] + }, + { + "id": "TRO201", + "fbType": "1Sep", + "comment": "TRO 201 (1Sep)", + "entries": [ + { + "jamArea": "JA1109_2", + "dbRef": "\"DB_JamArea1109\".stJam1109_2", + "from": "TRO200", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1102_1", + "dbRef": "\"DB_JamArea1102\".stJam1102_1", + "to": "TRO202", + "kind": "normal" + } + ] + }, + { + "id": "TRO202", + "fbType": "1Sep1Swi", + "comment": "TRO 202 (1Sep1Switch)+Scanner(BX2103)", + "entries": [ + { + "jamArea": "JA1102_1", + "dbRef": "\"DB_JamArea1102\".stJam1102_1", + "from": "TRO201", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1101_1", + "dbRef": "\"DB_JamArea1101\".stJam1101_1", + "to": "TRO211", + "kind": "dir2" + }, + { + "jamArea": "JA1102_2", + "dbRef": "\"DB_JamArea1102\".stJam1102_2", + "to": "TRO214", + "kind": "normal" + } + ] + }, + { + "id": "TRO203", + "fbType": "1Sep1Swi", + "comment": "TRO 203 (1Sep1Switch) + Scanner (BX2111)", + "entries": [ + { + "jamArea": "JA1103_1", + "dbRef": "\"DB_JamArea1103\".stJam1103_1", + "from": "TRO208", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1103_2", + "dbRef": "\"DB_JamArea1103\".stJam1103_2", + "to": "TRO204", + "kind": "dir2" + }, + { + "jamArea": "JA1105_1", + "dbRef": "\"DB_JamArea1105\".stJam1105_1", + "to": "TRO209", + "kind": "normal" + } + ] + }, + { + "id": "TRO204", + "fbType": "1Sep1Swi", + "comment": "TRO 204(1Sep1Switch) + Scanner(BX2112)", + "entries": [ + { + "jamArea": "JA1103_2", + "dbRef": "\"DB_JamArea1103\".stJam1103_2", + "from": "TRO211", + "kind": "normal" + }, + { + "jamArea": "JA1103_2", + "dbRef": "\"DB_JamArea1103\".stJam1103_2", + "from": "TRO203", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA1104_3", + "dbRef": "\"DB_JamArea1104\".stJam1104_3", + "to": "TRO207", + "kind": "dir2" + }, + { + "jamArea": "JA1106_1", + "dbRef": "\"DB_JamArea1106\".stJam1106_1", + "to": "TRO212", + "kind": "normal" + } + ] + }, + { + "id": "TRO205", + "fbType": "1Sep1Swi", + "comment": "TRO 205 (1Sep1Switch) + Scanner(BX2114)", + "entries": [ + { + "jamArea": "JA1104_1", + "dbRef": "\"DB_JamArea1104\".stJam1104_1", + "from": "TRO217", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1104_2", + "dbRef": "\"DB_JamArea1104\".stJam1104_2", + "to": "TRO206", + "kind": "normal" + }, + { + "jamArea": "JA1108_1", + "dbRef": "\"DB_JamArea1108\".stJam1108_1", + "to": "TRO218", + "kind": "dir2" + } + ] + }, + { + "id": "TRO206", + "fbType": "1Sep1Swi", + "comment": "TRO 206 (1Sep1Switch)+Scanner(BX2113)", + "entries": [ + { + "jamArea": "JA1104_2", + "dbRef": "\"DB_JamArea1104\".stJam1104_2", + "from": "TRO214", + "kind": "normal" + }, + { + "jamArea": "JA1104_2", + "dbRef": "\"DB_JamArea1104\".stJam1104_2", + "from": "TRO205", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1104_3", + "dbRef": "\"DB_JamArea1104\".stJam1104_3", + "to": "TRO207", + "kind": "normal" + }, + { + "jamArea": "JA1107_1", + "dbRef": "\"DB_JamArea1107\".stJam1107_1", + "to": "TRO215", + "kind": "dir2" + } + ] + }, + { + "id": "TRO207", + "fbType": "1Sep", + "comment": "TRO 207(1Sep)", + "entries": [ + { + "jamArea": "JA1104_3", + "dbRef": "\"DB_JamArea1104\".stJam1104_3", + "from": "TRO204", + "kind": "dir2" + }, + { + "jamArea": "JA1104_3", + "dbRef": "\"DB_JamArea1104\".stJam1104_3", + "from": "TRO206", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "IO_Device_UH02_TO_UH01.stCARRIER_INFO", + "dbRef": "IO_Device_UH02_TO_UH01.stCARRIER_INFO", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO208", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO208", + "entries": [ + { + "jamArea": "JA1101_2", + "dbRef": "\"DB_JamArea1101\".stJam1101_2", + "from": "TRO211", + "kind": "bypass" + }, + { + "jamArea": "JA1101_2", + "dbRef": "\"DB_JamArea1101\".stJam1101_2", + "from": "TRO210", + "kind": "normal" + }, + { + "jamArea": "Storage1.1.1", + "dbRef": "Storage1.1.1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1103_1", + "dbRef": "\"DB_JamArea1103\".stJam1103_1", + "to": "TRO203", + "kind": "normal" + } + ] + }, + { + "id": "TRO209", + "fbType": "Vario", + "comment": "TRO 209 (Vario)", + "entries": [ + { + "jamArea": "JA1105_1", + "dbRef": "\"DB_JamArea1105\".stJam1105_1", + "from": "TRO203", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1105_2", + "dbRef": "\"DB_JamArea1105\".stJam1105_2", + "to": "TRO210", + "kind": "finger" + } + ] + }, + { + "id": "TRO210", + "fbType": "1Sep", + "comment": "TRO 210 (1Sep)", + "entries": [ + { + "jamArea": "JA1105_2", + "dbRef": "\"DB_JamArea1105\".stJam1105_2", + "from": "TRO209", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1101_2", + "dbRef": "\"DB_JamArea1101\".stJam1101_2", + "to": "TRO208", + "kind": "normal" + } + ] + }, + { + "id": "TRO211", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO211", + "entries": [ + { + "jamArea": "JA1101_1", + "dbRef": "\"DB_JamArea1101\".stJam1101_1", + "from": "TRO202", + "kind": "dir2" + }, + { + "jamArea": "JA1101_1", + "dbRef": "\"DB_JamArea1101\".stJam1101_1", + "from": "TRO213", + "kind": "normal" + }, + { + "jamArea": "Storage1.1.2", + "dbRef": "Storage1.1.2", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1101_2", + "dbRef": "\"DB_JamArea1101\".stJam1101_2", + "to": "TRO208", + "kind": "bypass" + }, + { + "jamArea": "JA1103_2", + "dbRef": "\"DB_JamArea1103\".stJam1103_2", + "to": "TRO204", + "kind": "normal" + } + ] + }, + { + "id": "TRO212", + "fbType": "Vario", + "comment": "TRO 212 (Vario)", + "entries": [ + { + "jamArea": "JA1106_1", + "dbRef": "\"DB_JamArea1106\".stJam1106_1", + "from": "TRO204", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1106_2", + "dbRef": "\"DB_JamArea1106\".stJam1106_2", + "to": "TRO213", + "kind": "finger" + } + ] + }, + { + "id": "TRO213", + "fbType": "1Sep", + "comment": "TRO 213 (1Sep)", + "entries": [ + { + "jamArea": "JA1106_2", + "dbRef": "\"DB_JamArea1106\".stJam1106_2", + "from": "TRO212", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1101_1", + "dbRef": "\"DB_JamArea1101\".stJam1101_1", + "to": "TRO211", + "kind": "normal" + } + ] + }, + { + "id": "TRO214", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO214", + "entries": [ + { + "jamArea": "JA1102_2", + "dbRef": "\"DB_JamArea1102\".stJam1102_2", + "from": "TRO202", + "kind": "normal" + }, + { + "jamArea": "JA1102_2", + "dbRef": "\"DB_JamArea1102\".stJam1102_2", + "from": "TRO216", + "kind": "normal" + }, + { + "jamArea": "Storage1.1.3", + "dbRef": "Storage1.1.3", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1102_3", + "dbRef": "\"DB_JamArea1102\".stJam1102_3", + "to": "TRO217", + "kind": "bypass" + }, + { + "jamArea": "JA1104_2", + "dbRef": "\"DB_JamArea1104\".stJam1104_2", + "to": "TRO206", + "kind": "normal" + } + ] + }, + { + "id": "TRO215", + "fbType": "Vario", + "comment": "TRO 215 (Vario)", + "entries": [ + { + "jamArea": "JA1107_1", + "dbRef": "\"DB_JamArea1107\".stJam1107_1", + "from": "TRO206", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA1107_2", + "dbRef": "\"DB_JamArea1107\".stJam1107_2", + "to": "TRO216", + "kind": "finger" + } + ] + }, + { + "id": "TRO216", + "fbType": "1Sep", + "comment": "TRO 216 (1Sep)", + "entries": [ + { + "jamArea": "JA1107_2", + "dbRef": "\"DB_JamArea1107\".stJam1107_2", + "from": "TRO215", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1102_2", + "dbRef": "\"DB_JamArea1102\".stJam1102_2", + "to": "TRO214", + "kind": "normal" + } + ] + }, + { + "id": "TRO217", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO217", + "entries": [ + { + "jamArea": "JA1102_3", + "dbRef": "\"DB_JamArea1102\".stJam1102_3", + "from": "TRO214", + "kind": "bypass" + }, + { + "jamArea": "JA1102_3", + "dbRef": "\"DB_JamArea1102\".stJam1102_3", + "from": "TRO219", + "kind": "normal" + }, + { + "jamArea": "Storage1.1.4", + "dbRef": "Storage1.1.4", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1104_1", + "dbRef": "\"DB_JamArea1104\".stJam1104_1", + "to": "TRO205", + "kind": "normal" + } + ] + }, + { + "id": "TRO218", + "fbType": "Vario", + "comment": "TRO 218 (Vario)", + "entries": [ + { + "jamArea": "JA1108_1", + "dbRef": "\"DB_JamArea1108\".stJam1108_1", + "from": "TRO205", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA1108_2", + "dbRef": "\"DB_JamArea1108\".stJam1108_2", + "to": "TRO219", + "kind": "finger" + } + ] + }, + { + "id": "TRO219", + "fbType": "1Sep", + "comment": "TRO 219(1Sep)", + "entries": [ + { + "jamArea": "JA1108_2", + "dbRef": "\"DB_JamArea1108\".stJam1108_2", + "from": "TRO218", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1102_3", + "dbRef": "\"DB_JamArea1102\".stJam1102_3", + "to": "TRO217", + "kind": "normal" + } + ] + }, + { + "id": "TRO220", + "fbType": "Vario", + "comment": "TRO 220 (Vario)", + "entries": [ + { + "jamArea": "JA1209_1", + "dbRef": "\"DB_JamArea1209\".stJam1209_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1209_2", + "dbRef": "\"DB_JamArea1209\".stJam1209_2", + "to": "TRO221", + "kind": "finger" + } + ] + }, + { + "id": "TRO221", + "fbType": "1Sep", + "comment": "TRO 221 (1Sep)", + "entries": [ + { + "jamArea": "JA1209_2", + "dbRef": "\"DB_JamArea1209\".stJam1209_2", + "from": "TRO220", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1202_1", + "dbRef": "\"DB_JamArea1202\".stJam1202_1", + "to": "TRO222", + "kind": "normal" + } + ] + }, + { + "id": "TRO222", + "fbType": "1Sep1Swi", + "comment": "TRO 222 (1Sep1Switch)+Scanner(BX2121)", + "entries": [ + { + "jamArea": "JA1202_1", + "dbRef": "\"DB_JamArea1202\".stJam1202_1", + "from": "TRO221", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1201_1", + "dbRef": "\"DB_JamArea1201\".stJam1201_1", + "to": "TRO231", + "kind": "dir2" + }, + { + "jamArea": "JA1202_2", + "dbRef": "\"DB_JamArea1202\".stJam1202_2", + "to": "TRO234", + "kind": "normal" + } + ] + }, + { + "id": "TRO223", + "fbType": "1Sep1Swi", + "comment": "TRO 223 (1Sep1Switch)+Scanner(BX2126)", + "entries": [ + { + "jamArea": "JA1203_1", + "dbRef": "\"DB_JamArea1203\".stJam1203_1", + "from": "TRO228", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1203_2", + "dbRef": "\"DB_JamArea1203\".stJam1203_2", + "to": "TRO224", + "kind": "dir2" + }, + { + "jamArea": "JA1205_1", + "dbRef": "\"DB_JamArea1205\".stJam1205_1", + "to": "TRO229", + "kind": "normal" + } + ] + }, + { + "id": "TRO224", + "fbType": "1Sep1Swi", + "comment": "TRO 224 (1Sep1Switch)+Scanner(BX2127)", + "entries": [ + { + "jamArea": "JA1203_2", + "dbRef": "\"DB_JamArea1203\".stJam1203_2", + "from": "TRO231", + "kind": "normal" + }, + { + "jamArea": "JA1203_2", + "dbRef": "\"DB_JamArea1203\".stJam1203_2", + "from": "TRO223", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA1204_3", + "dbRef": "\"DB_JamArea1204\".stJam1204_3", + "to": "TRO227", + "kind": "dir2" + }, + { + "jamArea": "JA1206_1", + "dbRef": "\"DB_JamArea1206\".stJam1206_1", + "to": "TRO232", + "kind": "normal" + } + ] + }, + { + "id": "TRO225", + "fbType": "1Sep1Swi", + "comment": "TRO 225(1Sep1Switch)+Scanner(BX2129)", + "entries": [ + { + "jamArea": "JA1204_1", + "dbRef": "\"DB_JamArea1204\".stJam1204_1", + "from": "TRO237", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1204_2", + "dbRef": "\"DB_JamArea1204\".stJam1204_2", + "to": "TRO226", + "kind": "normal" + }, + { + "jamArea": "JA1208_1", + "dbRef": "\"DB_JamArea1208\".stJam1208_1", + "to": "TRO238", + "kind": "dir2" + } + ] + }, + { + "id": "TRO226", + "fbType": "1Sep1Swi", + "comment": "TRO 226 (1Sep1Switch)+Scanner(BX2128)", + "entries": [ + { + "jamArea": "JA1204_2", + "dbRef": "\"DB_JamArea1204\".stJam1204_2", + "from": "TRO234", + "kind": "normal" + }, + { + "jamArea": "JA1204_2", + "dbRef": "\"DB_JamArea1204\".stJam1204_2", + "from": "TRO225", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1204_3", + "dbRef": "\"DB_JamArea1204\".stJam1204_3", + "to": "TRO227", + "kind": "normal" + }, + { + "jamArea": "JA1207_1", + "dbRef": "\"DB_JamArea1207\".stJam1207_1", + "to": "TRO235", + "kind": "dir2" + } + ] + }, + { + "id": "TRO227", + "fbType": "1Sep", + "comment": "TRO 227 (1Sep)", + "entries": [ + { + "jamArea": "JA1204_3", + "dbRef": "\"DB_JamArea1204\".stJam1204_3", + "from": "TRO224", + "kind": "dir2" + }, + { + "jamArea": "JA1204_3", + "dbRef": "\"DB_JamArea1204\".stJam1204_3", + "from": "TRO226", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_1", + "dbRef": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_1", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO228", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO228", + "entries": [ + { + "jamArea": "JA1201_2", + "dbRef": "\"DB_JamArea1201\".stJam1201_2", + "from": "TRO231", + "kind": "bypass" + }, + { + "jamArea": "JA1201_2", + "dbRef": "\"DB_JamArea1201\".stJam1201_2", + "from": "TRO230", + "kind": "normal" + }, + { + "jamArea": "Storage1.2.1", + "dbRef": "Storage1.2.1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1203_1", + "dbRef": "\"DB_JamArea1203\".stJam1203_1", + "to": "TRO223", + "kind": "normal" + } + ] + }, + { + "id": "TRO229", + "fbType": "Vario", + "comment": "TRO 229 (Vario)", + "entries": [ + { + "jamArea": "JA1205_1", + "dbRef": "\"DB_JamArea1205\".stJam1205_1", + "from": "TRO223", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1205_2", + "dbRef": "\"DB_JamArea1205\".stJam1205_2", + "to": "TRO230", + "kind": "finger" + } + ] + }, + { + "id": "TRO230", + "fbType": "1Sep", + "comment": "TRO 230 (1Sep)", + "entries": [ + { + "jamArea": "JA1205_2", + "dbRef": "\"DB_JamArea1205\".stJam1205_2", + "from": "TRO229", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1201_2", + "dbRef": "\"DB_JamArea1201\".stJam1201_2", + "to": "TRO228", + "kind": "normal" + } + ] + }, + { + "id": "TRO231", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO231", + "entries": [ + { + "jamArea": "JA1201_1", + "dbRef": "\"DB_JamArea1201\".stJam1201_1", + "from": "TRO222", + "kind": "dir2" + }, + { + "jamArea": "JA1201_1", + "dbRef": "\"DB_JamArea1201\".stJam1201_1", + "from": "TRO233", + "kind": "normal" + }, + { + "jamArea": "Storage1.2.2", + "dbRef": "Storage1.2.2", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1201_2", + "dbRef": "\"DB_JamArea1201\".stJam1201_2", + "to": "TRO228", + "kind": "bypass" + }, + { + "jamArea": "JA1203_2", + "dbRef": "\"DB_JamArea1203\".stJam1203_2", + "to": "TRO224", + "kind": "normal" + } + ] + }, + { + "id": "TRO232", + "fbType": "Vario", + "comment": "TRO 232 (Vario)", + "entries": [ + { + "jamArea": "JA1206_1", + "dbRef": "\"DB_JamArea1206\".stJam1206_1", + "from": "TRO224", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1206_2", + "dbRef": "\"DB_JamArea1206\".stJam1206_2", + "to": "TRO233", + "kind": "finger" + } + ] + }, + { + "id": "TRO233", + "fbType": "1Sep", + "comment": "TRO 233 (1Sep)", + "entries": [ + { + "jamArea": "JA1206_2", + "dbRef": "\"DB_JamArea1206\".stJam1206_2", + "from": "TRO232", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1201_1", + "dbRef": "\"DB_JamArea1201\".stJam1201_1", + "to": "TRO231", + "kind": "normal" + } + ] + }, + { + "id": "TRO234", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO234", + "entries": [ + { + "jamArea": "JA1202_2", + "dbRef": "\"DB_JamArea1202\".stJam1202_2", + "from": "TRO222", + "kind": "normal" + }, + { + "jamArea": "JA1202_2", + "dbRef": "\"DB_JamArea1202\".stJam1202_2", + "from": "TRO236", + "kind": "normal" + }, + { + "jamArea": "Storage1.2.3", + "dbRef": "Storage1.2.3", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1202_3", + "dbRef": "\"DB_JamArea1202\".stJam1202_3", + "to": "TRO237", + "kind": "bypass" + }, + { + "jamArea": "JA1204_2", + "dbRef": "\"DB_JamArea1204\".stJam1204_2", + "to": "TRO226", + "kind": "normal" + } + ] + }, + { + "id": "TRO235", + "fbType": "Vario", + "comment": "TRO 235 (Vario)", + "entries": [ + { + "jamArea": "JA1207_1", + "dbRef": "\"DB_JamArea1207\".stJam1207_1", + "from": "TRO226", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA1207_2", + "dbRef": "\"DB_JamArea1207\".stJam1207_2", + "to": "TRO236", + "kind": "finger" + } + ] + }, + { + "id": "TRO236", + "fbType": "1Sep", + "comment": "TRO 236 (1Sep)", + "entries": [ + { + "jamArea": "JA1207_2", + "dbRef": "\"DB_JamArea1207\".stJam1207_2", + "from": "TRO235", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1202_2", + "dbRef": "\"DB_JamArea1202\".stJam1202_2", + "to": "TRO234", + "kind": "normal" + } + ] + }, + { + "id": "TRO237", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO237", + "entries": [ + { + "jamArea": "JA1202_3", + "dbRef": "\"DB_JamArea1202\".stJam1202_3", + "from": "TRO234", + "kind": "bypass" + }, + { + "jamArea": "JA1202_3", + "dbRef": "\"DB_JamArea1202\".stJam1202_3", + "from": "TRO239", + "kind": "normal" + }, + { + "jamArea": "Storage1.2.4", + "dbRef": "Storage1.2.4", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1204_1", + "dbRef": "\"DB_JamArea1204\".stJam1204_1", + "to": "TRO225", + "kind": "normal" + } + ] + }, + { + "id": "TRO238", + "fbType": "Vario", + "comment": "TRO 238 (Vario)", + "entries": [ + { + "jamArea": "JA1208_1", + "dbRef": "\"DB_JamArea1208\".stJam1208_1", + "from": "TRO225", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA1208_2", + "dbRef": "\"DB_JamArea1208\".stJam1208_2", + "to": "TRO239", + "kind": "finger" + } + ] + }, + { + "id": "TRO239", + "fbType": "1Sep", + "comment": "TRO 239 (1Sep)", + "entries": [ + { + "jamArea": "JA1208_2", + "dbRef": "\"DB_JamArea1208\".stJam1208_2", + "from": "TRO238", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1202_3", + "dbRef": "\"DB_JamArea1202\".stJam1202_3", + "to": "TRO237", + "kind": "normal" + } + ] + }, + { + "id": "TRO240", + "fbType": "Vario", + "comment": "TRO 240 (Vario)", + "entries": [ + { + "jamArea": "JA1309_1", + "dbRef": "\"DB_JamArea1309\".stJam1309_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1309_2", + "dbRef": "\"DB_JamArea1309\".stJam1309_2", + "to": "TRO241", + "kind": "finger" + } + ] + }, + { + "id": "TRO241", + "fbType": "1Sep", + "comment": "TRO 241(1Sep)", + "entries": [ + { + "jamArea": "JA1309_2", + "dbRef": "\"DB_JamArea1309\".stJam1309_2", + "from": "TRO240", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1304_1", + "dbRef": "\"DB_JamArea1304\".stJam1304_1", + "to": "TRO242", + "kind": "normal" + } + ] + }, + { + "id": "TRO242", + "fbType": "1Sep1Swi", + "comment": "TRO 242 (1Sep1Switch)+Scanner(BX2130)", + "entries": [ + { + "jamArea": "JA1304_1", + "dbRef": "\"DB_JamArea1304\".stJam1304_1", + "from": "TRO241", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1303_1", + "dbRef": "\"DB_JamArea1303\".stJam1303_1", + "to": "TRO251", + "kind": "normal" + }, + { + "jamArea": "JA1304_2", + "dbRef": "\"DB_JamArea1304\".stJam1304_2", + "to": "TRO254", + "kind": "dir2" + } + ] + }, + { + "id": "TRO243", + "fbType": "1Sep1Swi", + "comment": "TRO 243 (1Sep1Switch)+Scanner(BX3137)", + "entries": [ + { + "jamArea": "JA1301_1", + "dbRef": "\"DB_JamArea1301\".stJam1301_1", + "from": "TRO248", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1301_2", + "dbRef": "\"DB_JamArea1301\".stJam1301_2", + "to": "TRO244", + "kind": "normal" + }, + { + "jamArea": "JA1305_1", + "dbRef": "\"DB_JamArea1305\".stJam1305_1", + "to": "TRO249", + "kind": "dir2" + } + ] + }, + { + "id": "TRO244", + "fbType": "1Sep1Swi", + "comment": "TRO 244 (1Sep1Switch)+Scanner(BX2136)", + "entries": [ + { + "jamArea": "JA1301_2", + "dbRef": "\"DB_JamArea1301\".stJam1301_2", + "from": "TRO251", + "kind": "normal" + }, + { + "jamArea": "JA1301_2", + "dbRef": "\"DB_JamArea1301\".stJam1301_2", + "from": "TRO243", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1306_1", + "dbRef": "\"DB_JamArea1306\".stJam1306_1", + "to": "TRO252", + "kind": "dir2" + }, + { + "jamArea": "JA1302_3", + "dbRef": "\"DB_JamArea1302\".stJam1302_3", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO245", + "fbType": "1Sep1Swi", + "comment": "TRO 245 (1Sep1Switch)+Scanner(BX2138)", + "entries": [ + { + "jamArea": "JA1302_1", + "dbRef": "\"DB_JamArea1302\".stJam1302_1", + "from": "TRO257", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1302_2", + "dbRef": "\"DB_JamArea1302\".stJam1302_2", + "to": "TRO246", + "kind": "dir2" + }, + { + "jamArea": "JA1308_1", + "dbRef": "\"DB_JamArea1308\".stJam1308_1", + "to": "TRO258", + "kind": "normal" + } + ] + }, + { + "id": "TRO246", + "fbType": "1Sep1Swi", + "comment": "TRO 246 (1Sep1Switch)+Scanner(BX2137)", + "entries": [ + { + "jamArea": "JA1302_2", + "dbRef": "\"DB_JamArea1302\".stJam1302_2", + "from": "TRO254", + "kind": "normal" + }, + { + "jamArea": "JA1302_2", + "dbRef": "\"DB_JamArea1302\".stJam1302_2", + "from": "TRO245", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA1307_1", + "dbRef": "\"DB_JamArea1307\".stJam1307_1", + "to": "TRO255", + "kind": "normal" + }, + { + "jamArea": "JA1302_3", + "dbRef": "\"DB_JamArea1302\".stJam1302_3", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO247", + "fbType": "1Sep", + "comment": "TRO 247(1Sep)", + "entries": [], + "exits": [ + { + "jamArea": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_2", + "dbRef": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_2", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO248", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO248", + "entries": [ + { + "jamArea": "JA1303_2", + "dbRef": "\"DB_JamArea1303\".stJam1303_2", + "from": "TRO251", + "kind": "bypass" + }, + { + "jamArea": "JA1303_2", + "dbRef": "\"DB_JamArea1303\".stJam1303_2", + "from": "TRO250", + "kind": "normal" + }, + { + "jamArea": "Storage1.3.1", + "dbRef": "Storage1.3.1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1301_1", + "dbRef": "\"DB_JamArea1301\".stJam1301_1", + "to": "TRO243", + "kind": "normal" + } + ] + }, + { + "id": "TRO249", + "fbType": "Vario", + "comment": "TRO 249 (Vario)", + "entries": [ + { + "jamArea": "JA1305_1", + "dbRef": "\"DB_JamArea1305\".stJam1305_1", + "from": "TRO243", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA1305_2", + "dbRef": "\"DB_JamArea1305\".stJam1305_2", + "to": "TRO250", + "kind": "finger" + } + ] + }, + { + "id": "TRO250", + "fbType": "1Sep", + "comment": "TRO 250 (1Sep)", + "entries": [ + { + "jamArea": "JA1305_2", + "dbRef": "\"DB_JamArea1305\".stJam1305_2", + "from": "TRO249", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1303_2", + "dbRef": "\"DB_JamArea1303\".stJam1303_2", + "to": "TRO248", + "kind": "normal" + } + ] + }, + { + "id": "TRO251", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO251", + "entries": [ + { + "jamArea": "JA1303_1", + "dbRef": "\"DB_JamArea1303\".stJam1303_1", + "from": "TRO242", + "kind": "normal" + }, + { + "jamArea": "JA1303_1", + "dbRef": "\"DB_JamArea1303\".stJam1303_1", + "from": "TRO253", + "kind": "normal" + }, + { + "jamArea": "Storage1.3.2", + "dbRef": "Storage1.3.2", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1301_2", + "dbRef": "\"DB_JamArea1301\".stJam1301_2", + "to": "TRO244", + "kind": "normal" + }, + { + "jamArea": "JA1303_2", + "dbRef": "\"DB_JamArea1303\".stJam1303_2", + "to": "TRO248", + "kind": "bypass" + } + ] + }, + { + "id": "TRO252", + "fbType": "Vario", + "comment": "TRO 252 (Vario)", + "entries": [ + { + "jamArea": "JA1306_1", + "dbRef": "\"DB_JamArea1306\".stJam1306_1", + "from": "TRO244", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA1306_2", + "dbRef": "\"DB_JamArea1306\".stJam1306_2", + "to": "TRO253", + "kind": "finger" + } + ] + }, + { + "id": "TRO253", + "fbType": "1Sep", + "comment": "TRO 253 (1Sep)", + "entries": [ + { + "jamArea": "JA1306_2", + "dbRef": "\"DB_JamArea1306\".stJam1306_2", + "from": "TRO252", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1303_1", + "dbRef": "\"DB_JamArea1303\".stJam1303_1", + "to": "TRO251", + "kind": "normal" + } + ] + }, + { + "id": "TRO254", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO254", + "entries": [ + { + "jamArea": "JA1304_2", + "dbRef": "\"DB_JamArea1304\".stJam1304_2", + "from": "TRO242", + "kind": "dir2" + }, + { + "jamArea": "JA1304_2", + "dbRef": "\"DB_JamArea1304\".stJam1304_2", + "from": "TRO256", + "kind": "normal" + }, + { + "jamArea": "Storage1.3.3", + "dbRef": "Storage1.3.3", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1302_2", + "dbRef": "\"DB_JamArea1302\".stJam1302_2", + "to": "TRO246", + "kind": "normal" + }, + { + "jamArea": "JA1304_3", + "dbRef": "\"DB_JamArea1304\".stJam1304_3", + "to": "TRO257", + "kind": "bypass" + } + ] + }, + { + "id": "TRO255", + "fbType": "Vario", + "comment": "TRO 255 (Vario)", + "entries": [ + { + "jamArea": "JA1307_1", + "dbRef": "\"DB_JamArea1307\".stJam1307_1", + "from": "TRO246", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1307_2", + "dbRef": "\"DB_JamArea1307\".stJam1307_2", + "to": "TRO256", + "kind": "finger" + } + ] + }, + { + "id": "TRO256", + "fbType": "1Sep", + "comment": "TRO 256 (1Sep)", + "entries": [ + { + "jamArea": "JA1307_2", + "dbRef": "\"DB_JamArea1307\".stJam1307_2", + "from": "TRO255", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1304_2", + "dbRef": "\"DB_JamArea1304\".stJam1304_2", + "to": "TRO254", + "kind": "normal" + } + ] + }, + { + "id": "TRO257", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO257", + "entries": [ + { + "jamArea": "JA1304_3", + "dbRef": "\"DB_JamArea1304\".stJam1304_3", + "from": "TRO254", + "kind": "bypass" + }, + { + "jamArea": "JA1304_3", + "dbRef": "\"DB_JamArea1304\".stJam1304_3", + "from": "TRO259", + "kind": "normal" + }, + { + "jamArea": "Storage1.3.4", + "dbRef": "Storage1.3.4", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1302_1", + "dbRef": "\"DB_JamArea1302\".stJam1302_1", + "to": "TRO245", + "kind": "normal" + } + ] + }, + { + "id": "TRO258", + "fbType": "Vario", + "comment": "TRO 258 (Vario)", + "entries": [ + { + "jamArea": "JA1308_1", + "dbRef": "\"DB_JamArea1308\".stJam1308_1", + "from": "TRO245", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1308_2", + "dbRef": "\"DB_JamArea1308\".stJam1308_2", + "to": "TRO259", + "kind": "finger" + } + ] + }, + { + "id": "TRO259", + "fbType": "1Sep", + "comment": "TRO 259 (1Sep)", + "entries": [ + { + "jamArea": "JA1308_2", + "dbRef": "\"DB_JamArea1308\".stJam1308_2", + "from": "TRO258", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1304_3", + "dbRef": "\"DB_JamArea1304\".stJam1304_3", + "to": "TRO257", + "kind": "normal" + } + ] + }, + { + "id": "TRO260", + "fbType": "Vario", + "comment": "TRO 260 (Vario) + Scanner (BX2115)", + "entries": [ + { + "jamArea": "JA1601_1", + "dbRef": "\"DB_JamArea1601\".stJam1601_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1601_2", + "dbRef": "\"DB_JamArea1601\".stJam1601_2", + "to": "TRO261", + "kind": "finger" + } + ] + }, + { + "id": "TRO261", + "fbType": "1Sep", + "comment": "TRO 261 (1Sep)", + "entries": [ + { + "jamArea": "JA1601_2", + "dbRef": "\"DB_JamArea1601\".stJam1601_2", + "from": "TRO260", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1110_2", + "dbRef": "\"DB_JamArea1110\".stJam1110_2", + "to": "TRO274", + "kind": "normal" + } + ] + }, + { + "id": "TRO262", + "fbType": "Vario", + "comment": "TRO 262 (Vario) + Scanner (BX2109)", + "entries": [ + { + "jamArea": "JA1501_1", + "dbRef": "\"DB_JamArea1501\".stJam1501_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1501_2", + "dbRef": "\"DB_JamArea1501\".stJam1501_2", + "to": "TRO263", + "kind": "finger" + } + ] + }, + { + "id": "TRO263", + "fbType": "1Sep", + "comment": "TRO 263 (1Sep)", + "entries": [ + { + "jamArea": "JA1501_2", + "dbRef": "\"DB_JamArea1501\".stJam1501_2", + "from": "TRO262", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1110_3", + "dbRef": "\"DB_JamArea1110\".stJam1110_3", + "to": "TRO266", + "kind": "normal" + } + ] + }, + { + "id": "TRO264", + "fbType": "Vario", + "comment": "TRO 264 (Vario) + Scanner (BX2108)", + "entries": [ + { + "jamArea": "JA1401_1", + "dbRef": "\"DB_JamArea1401\".stJam1401_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA1401_2", + "dbRef": "\"DB_JamArea1401\".stJam1401_2", + "to": "TRO265", + "kind": "finger" + } + ] + }, + { + "id": "TRO265", + "fbType": "1Sep", + "comment": "TRO 265 (1Sep)", + "entries": [ + { + "jamArea": "JA1401_2", + "dbRef": "\"DB_JamArea1401\".stJam1401_2", + "from": "TRO264", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA1110_4", + "dbRef": "\"DB_JamArea1110\".stJam1110_4", + "to": "TRO267", + "kind": "normal" + } + ] + }, + { + "id": "TRO266", + "fbType": "1Sep", + "comment": "TRO 266(1Sep)", + "entries": [ + { + "jamArea": "JA1110_3", + "dbRef": "\"DB_JamArea1110\".stJam1110_3", + "from": "TRO263", + "kind": "normal" + }, + { + "jamArea": "JA1110_3", + "dbRef": "\"DB_JamArea1110\".stJam1110_3", + "from": "TRO274", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1110_4", + "dbRef": "\"DB_JamArea1110\".stJam1110_4", + "to": "TRO267", + "kind": "normal" + } + ] + }, + { + "id": "TRO267", + "fbType": "1Sep2Swi", + "comment": "TRO 267 (1Sep2Switch)+Scanner(BX2100)", + "entries": [ + { + "jamArea": "JA1110_4", + "dbRef": "\"DB_JamArea1110\".stJam1110_4", + "from": "TRO265", + "kind": "normal" + }, + { + "jamArea": "JA1110_4", + "dbRef": "\"DB_JamArea1110\".stJam1110_4", + "from": "TRO266", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1110_5", + "dbRef": "\"DB_JamArea1110\".stJam1110_5", + "to": "TRO275", + "kind": "dir3" + } + ] + }, + { + "id": "TRO268", + "fbType": "1Sep2Swi", + "comment": "TRO 268 (1Sep2Switch)+Scanner(BX2101)", + "entries": [ + { + "jamArea": "JA1110_6", + "dbRef": "\"DB_JamArea1110\".stJam1110_6", + "from": "TRO275", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1110_1", + "dbRef": "\"DB_JamArea1110\".stJam1110_1", + "to": "TRO269", + "kind": "dir3" + } + ] + }, + { + "id": "TRO269", + "fbType": "1Sep", + "comment": "TRO 269 (1Sep)+Scanner (BX2102)", + "entries": [ + { + "jamArea": "JA1110_1", + "dbRef": "\"DB_JamArea1110\".stJam1110_1", + "from": "TRO268", + "kind": "dir3" + } + ], + "exits": [ + { + "jamArea": "JA1110_2", + "dbRef": "\"DB_JamArea1110\".stJam1110_2", + "to": "TRO274", + "kind": "normal" + } + ] + }, + { + "id": "TRO270", + "fbType": "Vario", + "comment": "TRO 270 (Vario)", + "entries": [ + { + "jamArea": "JA4701_1", + "dbRef": "\"DB_JamArea4701\".stJam4701_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [] + }, + { + "id": "TRO272", + "fbType": "Vario", + "comment": "TRO 272 (Vario)", + "entries": [ + { + "jamArea": "JA1801_1", + "dbRef": "\"DB_JamArea1801\".stJam1801_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [] + }, + { + "id": "TRO274", + "fbType": "1Sep", + "comment": "TRO 274 (1Sep)", + "entries": [ + { + "jamArea": "JA1110_2", + "dbRef": "\"DB_JamArea1110\".stJam1110_2", + "from": "TRO261", + "kind": "normal" + }, + { + "jamArea": "JA1110_2", + "dbRef": "\"DB_JamArea1110\".stJam1110_2", + "from": "TRO269", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA1110_3", + "dbRef": "\"DB_JamArea1110\".stJam1110_3", + "to": "TRO266", + "kind": "normal" + } + ] + }, + { + "id": "TRO275", + "fbType": "1Sep", + "comment": "TRO 275 (1Sep)", + "entries": [ + { + "jamArea": "JA1110_5", + "dbRef": "\"DB_JamArea1110\".stJam1110_5", + "from": "TRO267", + "kind": "dir3" + } + ], + "exits": [ + { + "jamArea": "JA1110_6", + "dbRef": "\"DB_JamArea1110\".stJam1110_6", + "to": "TRO268", + "kind": "normal" + } + ] + } + ], + "connections": [ + { + "from": "TRO202", + "to": "TRO211", + "jamArea": "JA1101_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1101\".stJam1101_1" + }, + { + "from": "TRO213", + "to": "TRO211", + "jamArea": "JA1101_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1101\".stJam1101_1" + }, + { + "from": "TRO211", + "to": "TRO208", + "jamArea": "JA1101_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea1101\".stJam1101_2" + }, + { + "from": "TRO210", + "to": "TRO208", + "jamArea": "JA1101_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1101\".stJam1101_2" + }, + { + "from": "TRO201", + "to": "TRO202", + "jamArea": "JA1102_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1102\".stJam1102_1" + }, + { + "from": "TRO202", + "to": "TRO214", + "jamArea": "JA1102_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1102\".stJam1102_2" + }, + { + "from": "TRO216", + "to": "TRO214", + "jamArea": "JA1102_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1102\".stJam1102_2" + }, + { + "from": "TRO214", + "to": "TRO217", + "jamArea": "JA1102_3", + "kind": "bypass", + "dbRef": "\"DB_JamArea1102\".stJam1102_3" + }, + { + "from": "TRO219", + "to": "TRO217", + "jamArea": "JA1102_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1102\".stJam1102_3" + }, + { + "from": "TRO208", + "to": "TRO203", + "jamArea": "JA1103_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1103\".stJam1103_1" + }, + { + "from": "TRO211", + "to": "TRO204", + "jamArea": "JA1103_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1103\".stJam1103_2" + }, + { + "from": "TRO203", + "to": "TRO204", + "jamArea": "JA1103_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea1103\".stJam1103_2" + }, + { + "from": "TRO217", + "to": "TRO205", + "jamArea": "JA1104_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1104\".stJam1104_1" + }, + { + "from": "TRO214", + "to": "TRO206", + "jamArea": "JA1104_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1104\".stJam1104_2" + }, + { + "from": "TRO205", + "to": "TRO206", + "jamArea": "JA1104_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1104\".stJam1104_2" + }, + { + "from": "TRO204", + "to": "TRO207", + "jamArea": "JA1104_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea1104\".stJam1104_3" + }, + { + "from": "TRO206", + "to": "TRO207", + "jamArea": "JA1104_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1104\".stJam1104_3" + }, + { + "from": "TRO203", + "to": "TRO209", + "jamArea": "JA1105_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1105\".stJam1105_1" + }, + { + "from": "TRO209", + "to": "TRO210", + "jamArea": "JA1105_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1105\".stJam1105_2" + }, + { + "from": "TRO204", + "to": "TRO212", + "jamArea": "JA1106_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1106\".stJam1106_1" + }, + { + "from": "TRO212", + "to": "TRO213", + "jamArea": "JA1106_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1106\".stJam1106_2" + }, + { + "from": "TRO206", + "to": "TRO215", + "jamArea": "JA1107_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1107\".stJam1107_1" + }, + { + "from": "TRO215", + "to": "TRO216", + "jamArea": "JA1107_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1107\".stJam1107_2" + }, + { + "from": "TRO205", + "to": "TRO218", + "jamArea": "JA1108_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1108\".stJam1108_1" + }, + { + "from": "TRO218", + "to": "TRO219", + "jamArea": "JA1108_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1108\".stJam1108_2" + }, + { + "from": "TRO200", + "to": "TRO201", + "jamArea": "JA1109_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1109\".stJam1109_2" + }, + { + "from": "TRO268", + "to": "TRO269", + "jamArea": "JA1110_1", + "kind": "dir3", + "dbRef": "\"DB_JamArea1110\".stJam1110_1" + }, + { + "from": "TRO261", + "to": "TRO274", + "jamArea": "JA1110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_2" + }, + { + "from": "TRO269", + "to": "TRO274", + "jamArea": "JA1110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_2" + }, + { + "from": "TRO263", + "to": "TRO266", + "jamArea": "JA1110_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_3" + }, + { + "from": "TRO274", + "to": "TRO266", + "jamArea": "JA1110_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_3" + }, + { + "from": "TRO265", + "to": "TRO267", + "jamArea": "JA1110_4", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_4" + }, + { + "from": "TRO266", + "to": "TRO267", + "jamArea": "JA1110_4", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_4" + }, + { + "from": "TRO267", + "to": "TRO275", + "jamArea": "JA1110_5", + "kind": "dir3", + "dbRef": "\"DB_JamArea1110\".stJam1110_5" + }, + { + "from": "TRO275", + "to": "TRO268", + "jamArea": "JA1110_6", + "kind": "normal", + "dbRef": "\"DB_JamArea1110\".stJam1110_6" + }, + { + "from": "TRO222", + "to": "TRO231", + "jamArea": "JA1201_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1201\".stJam1201_1" + }, + { + "from": "TRO233", + "to": "TRO231", + "jamArea": "JA1201_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1201\".stJam1201_1" + }, + { + "from": "TRO231", + "to": "TRO228", + "jamArea": "JA1201_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea1201\".stJam1201_2" + }, + { + "from": "TRO230", + "to": "TRO228", + "jamArea": "JA1201_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1201\".stJam1201_2" + }, + { + "from": "TRO221", + "to": "TRO222", + "jamArea": "JA1202_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1202\".stJam1202_1" + }, + { + "from": "TRO222", + "to": "TRO234", + "jamArea": "JA1202_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1202\".stJam1202_2" + }, + { + "from": "TRO236", + "to": "TRO234", + "jamArea": "JA1202_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1202\".stJam1202_2" + }, + { + "from": "TRO234", + "to": "TRO237", + "jamArea": "JA1202_3", + "kind": "bypass", + "dbRef": "\"DB_JamArea1202\".stJam1202_3" + }, + { + "from": "TRO239", + "to": "TRO237", + "jamArea": "JA1202_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1202\".stJam1202_3" + }, + { + "from": "TRO228", + "to": "TRO223", + "jamArea": "JA1203_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1203\".stJam1203_1" + }, + { + "from": "TRO231", + "to": "TRO224", + "jamArea": "JA1203_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1203\".stJam1203_2" + }, + { + "from": "TRO223", + "to": "TRO224", + "jamArea": "JA1203_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea1203\".stJam1203_2" + }, + { + "from": "TRO237", + "to": "TRO225", + "jamArea": "JA1204_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1204\".stJam1204_1" + }, + { + "from": "TRO234", + "to": "TRO226", + "jamArea": "JA1204_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1204\".stJam1204_2" + }, + { + "from": "TRO225", + "to": "TRO226", + "jamArea": "JA1204_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1204\".stJam1204_2" + }, + { + "from": "TRO224", + "to": "TRO227", + "jamArea": "JA1204_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea1204\".stJam1204_3" + }, + { + "from": "TRO226", + "to": "TRO227", + "jamArea": "JA1204_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1204\".stJam1204_3" + }, + { + "from": "TRO223", + "to": "TRO229", + "jamArea": "JA1205_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1205\".stJam1205_1" + }, + { + "from": "TRO229", + "to": "TRO230", + "jamArea": "JA1205_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1205\".stJam1205_2" + }, + { + "from": "TRO224", + "to": "TRO232", + "jamArea": "JA1206_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1206\".stJam1206_1" + }, + { + "from": "TRO232", + "to": "TRO233", + "jamArea": "JA1206_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1206\".stJam1206_2" + }, + { + "from": "TRO226", + "to": "TRO235", + "jamArea": "JA1207_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1207\".stJam1207_1" + }, + { + "from": "TRO235", + "to": "TRO236", + "jamArea": "JA1207_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1207\".stJam1207_2" + }, + { + "from": "TRO225", + "to": "TRO238", + "jamArea": "JA1208_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1208\".stJam1208_1" + }, + { + "from": "TRO238", + "to": "TRO239", + "jamArea": "JA1208_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1208\".stJam1208_2" + }, + { + "from": "TRO220", + "to": "TRO221", + "jamArea": "JA1209_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1209\".stJam1209_2" + }, + { + "from": "TRO248", + "to": "TRO243", + "jamArea": "JA1301_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1301\".stJam1301_1" + }, + { + "from": "TRO251", + "to": "TRO244", + "jamArea": "JA1301_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1301\".stJam1301_2" + }, + { + "from": "TRO243", + "to": "TRO244", + "jamArea": "JA1301_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1301\".stJam1301_2" + }, + { + "from": "TRO257", + "to": "TRO245", + "jamArea": "JA1302_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1302\".stJam1302_1" + }, + { + "from": "TRO254", + "to": "TRO246", + "jamArea": "JA1302_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1302\".stJam1302_2" + }, + { + "from": "TRO245", + "to": "TRO246", + "jamArea": "JA1302_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea1302\".stJam1302_2" + }, + { + "from": "TRO242", + "to": "TRO251", + "jamArea": "JA1303_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1303\".stJam1303_1" + }, + { + "from": "TRO253", + "to": "TRO251", + "jamArea": "JA1303_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1303\".stJam1303_1" + }, + { + "from": "TRO251", + "to": "TRO248", + "jamArea": "JA1303_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea1303\".stJam1303_2" + }, + { + "from": "TRO250", + "to": "TRO248", + "jamArea": "JA1303_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1303\".stJam1303_2" + }, + { + "from": "TRO241", + "to": "TRO242", + "jamArea": "JA1304_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1304\".stJam1304_1" + }, + { + "from": "TRO242", + "to": "TRO254", + "jamArea": "JA1304_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea1304\".stJam1304_2" + }, + { + "from": "TRO256", + "to": "TRO254", + "jamArea": "JA1304_2", + "kind": "normal", + "dbRef": "\"DB_JamArea1304\".stJam1304_2" + }, + { + "from": "TRO254", + "to": "TRO257", + "jamArea": "JA1304_3", + "kind": "bypass", + "dbRef": "\"DB_JamArea1304\".stJam1304_3" + }, + { + "from": "TRO259", + "to": "TRO257", + "jamArea": "JA1304_3", + "kind": "normal", + "dbRef": "\"DB_JamArea1304\".stJam1304_3" + }, + { + "from": "TRO243", + "to": "TRO249", + "jamArea": "JA1305_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1305\".stJam1305_1" + }, + { + "from": "TRO249", + "to": "TRO250", + "jamArea": "JA1305_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1305\".stJam1305_2" + }, + { + "from": "TRO244", + "to": "TRO252", + "jamArea": "JA1306_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea1306\".stJam1306_1" + }, + { + "from": "TRO252", + "to": "TRO253", + "jamArea": "JA1306_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1306\".stJam1306_2" + }, + { + "from": "TRO246", + "to": "TRO255", + "jamArea": "JA1307_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1307\".stJam1307_1" + }, + { + "from": "TRO255", + "to": "TRO256", + "jamArea": "JA1307_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1307\".stJam1307_2" + }, + { + "from": "TRO245", + "to": "TRO258", + "jamArea": "JA1308_1", + "kind": "normal", + "dbRef": "\"DB_JamArea1308\".stJam1308_1" + }, + { + "from": "TRO258", + "to": "TRO259", + "jamArea": "JA1308_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1308\".stJam1308_2" + }, + { + "from": "TRO240", + "to": "TRO241", + "jamArea": "JA1309_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1309\".stJam1309_2" + }, + { + "from": "TRO264", + "to": "TRO265", + "jamArea": "JA1401_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1401\".stJam1401_2" + }, + { + "from": "TRO262", + "to": "TRO263", + "jamArea": "JA1501_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1501\".stJam1501_2" + }, + { + "from": "TRO260", + "to": "TRO261", + "jamArea": "JA1601_2", + "kind": "finger", + "dbRef": "\"DB_JamArea1601\".stJam1601_2" + } + ], + "externals": [ + { + "node": "TRO200", + "direction": "in", + "jamArea": "JA1109_1", + "dbRef": "\"DB_JamArea1109\".stJam1109_1" + }, + { + "node": "TRO220", + "direction": "in", + "jamArea": "JA1209_1", + "dbRef": "\"DB_JamArea1209\".stJam1209_1" + }, + { + "node": "TRO244", + "direction": "out", + "jamArea": "JA1302_3", + "dbRef": "\"DB_JamArea1302\".stJam1302_3" + }, + { + "node": "TRO246", + "direction": "out", + "jamArea": "JA1302_3", + "dbRef": "\"DB_JamArea1302\".stJam1302_3" + }, + { + "node": "TRO240", + "direction": "in", + "jamArea": "JA1309_1", + "dbRef": "\"DB_JamArea1309\".stJam1309_1" + }, + { + "node": "TRO264", + "direction": "in", + "jamArea": "JA1401_1", + "dbRef": "\"DB_JamArea1401\".stJam1401_1" + }, + { + "node": "TRO262", + "direction": "in", + "jamArea": "JA1501_1", + "dbRef": "\"DB_JamArea1501\".stJam1501_1" + }, + { + "node": "TRO260", + "direction": "in", + "jamArea": "JA1601_1", + "dbRef": "\"DB_JamArea1601\".stJam1601_1" + }, + { + "node": "TRO272", + "direction": "in", + "jamArea": "JA1801_1", + "dbRef": "\"DB_JamArea1801\".stJam1801_1" + }, + { + "node": "TRO270", + "direction": "in", + "jamArea": "JA4701_1", + "dbRef": "\"DB_JamArea4701\".stJam4701_1" + }, + { + "node": "TRO208", + "direction": "in", + "jamArea": "Storage1.1.1", + "dbRef": "Storage1.1.1" + }, + { + "node": "TRO211", + "direction": "in", + "jamArea": "Storage1.1.2", + "dbRef": "Storage1.1.2" + }, + { + "node": "TRO214", + "direction": "in", + "jamArea": "Storage1.1.3", + "dbRef": "Storage1.1.3" + }, + { + "node": "TRO217", + "direction": "in", + "jamArea": "Storage1.1.4", + "dbRef": "Storage1.1.4" + }, + { + "node": "TRO228", + "direction": "in", + "jamArea": "Storage1.2.1", + "dbRef": "Storage1.2.1" + }, + { + "node": "TRO231", + "direction": "in", + "jamArea": "Storage1.2.2", + "dbRef": "Storage1.2.2" + }, + { + "node": "TRO234", + "direction": "in", + "jamArea": "Storage1.2.3", + "dbRef": "Storage1.2.3" + }, + { + "node": "TRO237", + "direction": "in", + "jamArea": "Storage1.2.4", + "dbRef": "Storage1.2.4" + }, + { + "node": "TRO248", + "direction": "in", + "jamArea": "Storage1.3.1", + "dbRef": "Storage1.3.1" + }, + { + "node": "TRO251", + "direction": "in", + "jamArea": "Storage1.3.2", + "dbRef": "Storage1.3.2" + }, + { + "node": "TRO254", + "direction": "in", + "jamArea": "Storage1.3.3", + "dbRef": "Storage1.3.3" + }, + { + "node": "TRO257", + "direction": "in", + "jamArea": "Storage1.3.4", + "dbRef": "Storage1.3.4" + }, + { + "node": "TRO207", + "direction": "out", + "jamArea": "IO_Device_UH02_TO_UH01.stCARRIER_INFO", + "dbRef": "IO_Device_UH02_TO_UH01.stCARRIER_INFO" + }, + { + "node": "TRO227", + "direction": "out", + "jamArea": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_1", + "dbRef": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_1" + }, + { + "node": "TRO247", + "direction": "out", + "jamArea": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_2", + "dbRef": "IO_Device_UH02_TO_UH01.stCARRIER_INFO_2" + } + ] + } +} \ No newline at end of file diff --git a/results/skeleton_UH03.json b/results/skeleton_UH03.json new file mode 100644 index 0000000..b9d4f5d --- /dev/null +++ b/results/skeleton_UH03.json @@ -0,0 +1,17653 @@ +{ + "$schema": "hmf-layout-v1.schema.json", + "generatedBy": "create_skel.py", + "plc": { + "id": "UH03", + "configName": "=A01+UH03-KF00" + }, + "statistics": { + "tags": 1608, + "sensors": 949, + "constants": 1608, + "units": 53, + "areas": 43, + "unassignedSignals": 123, + "troNodes": 84, + "connections": 102, + "externals": 30 + }, + "sensors": [ + { + "id": "SF0000", + "constant": "cInSF0000", + "hwAddress": "%E000.0", + "comment": "DT Anlage Aus", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 442428.2 + ] + }, + { + "id": "SF0001", + "constant": "cInSF0001", + "hwAddress": "%E000.1", + "comment": "LDT Anlage Ein", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 442158.2 + ] + }, + { + "id": "SF0002", + "constant": "cInSF0002", + "hwAddress": "%E000.2", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 441888.2 + ] + }, + { + "id": "SF0003", + "constant": "cInSF0003", + "hwAddress": "%E000.3", + "comment": "DT Lampentest", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 441618.2 + ] + }, + { + "id": "BP0004", + "constant": "cInBP0004", + "hwAddress": "%E000.4", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UH03", + "pos": [ + 202961.4, + 439216.6 + ] + }, + { + "id": "DI0005", + "constant": "cInDI0005", + "hwAddress": "%E000.5", + "comment": "Phasenausfall 400V", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 438873.1 + ] + }, + { + "id": "DI0006", + "constant": "cInDI0006", + "hwAddress": "%E000.6", + "comment": "Vorsicherung 400V UC031", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 438603.1 + ] + }, + { + "id": "DI0007", + "constant": "cInDI0007", + "hwAddress": "%E000.7", + "comment": "Vorsicherung 400V UC032", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 438333.1 + ] + }, + { + "id": "DI0010", + "constant": "cInDI0010", + "hwAddress": "%E001.0", + "comment": "Vorsicherung 400V UC033", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 438063.1 + ] + }, + { + "id": "DI0011", + "constant": "cInDI0011", + "hwAddress": "%E001.1", + "comment": "Vorsicherung 400V UC Reserve", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 437793.1 + ] + }, + { + "id": "DI0012", + "constant": "cInDI0012", + "hwAddress": "%E001.2", + "comment": "Vorsicherung 400V UC Reserve", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 437523.1 + ] + }, + { + "id": "DI0013", + "constant": "cInDI0013", + "hwAddress": "%E001.3", + "comment": "Feedback Hauptschütze aktiv", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.1, + 433696.6 + ] + }, + { + "id": "DI0014", + "constant": "cInDI0014", + "hwAddress": "%E001.4", + "comment": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.1, + 432580.9 + ] + }, + { + "id": "DI0015", + "constant": "cInDI0015", + "hwAddress": "%E001.5", + "comment": "Feedback Koppelrelais E-Stop-IF", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.1, + 431085.9 + ] + }, + { + "id": "DI0016", + "constant": "cInDI0016", + "hwAddress": "%E001.6", + "comment": "Sicherungsautomatenfall", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 437194.5 + ] + }, + { + "id": "DI0021", + "constant": "cInDI0021", + "hwAddress": "%E002.1", + "comment": "Vorsicherung 24V OK (FC021)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 436863.1 + ] + }, + { + "id": "DI0022", + "constant": "cInDI0022", + "hwAddress": "%E002.2", + "comment": "Vorsicherung 24V OK (FC022)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 436593.1 + ] + }, + { + "id": "DI0023", + "constant": "cInDI0023", + "hwAddress": "%E002.3", + "comment": "Vorsicherung 24V OK (FC023)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 436323.1 + ] + }, + { + "id": "DI0024", + "constant": "cInDI0024", + "hwAddress": "%E002.4", + "comment": "Vorsicherung 24V OK (FC024)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 436053.1 + ] + }, + { + "id": "DI0025", + "constant": "cInDI0025", + "hwAddress": "%E002.5", + "comment": "Vorsicherung 24V OK (FC025)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 435783.1 + ] + }, + { + "id": "DI0026", + "constant": "cInDI0026", + "hwAddress": "%E002.6", + "comment": "Vorsicherung 24V OK (FC026)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 435513.1 + ] + }, + { + "id": "DI0033", + "constant": "cInDI0033", + "hwAddress": "%E003.3", + "comment": "IF BMZ \"fire alarm\" 2", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "DI0034", + "constant": "cInDI0034", + "hwAddress": "%E003.4", + "comment": "IF BMZ \"fire alarm\" 1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252901.1, + 425990.4 + ] + }, + { + "id": "DI0035", + "constant": "cInDI0035", + "hwAddress": "%E003.5", + "comment": "IF BST \"No fire alarm\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 435185.0 + ] + }, + { + "id": "DI0036", + "constant": "cInDI0036", + "hwAddress": "%E003.6", + "comment": "IF BST \"Non fault\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 434915.0 + ] + }, + { + "id": "DI0037", + "constant": "cInDI0037", + "hwAddress": "%E003.7", + "comment": "IF BST \"FPC opened\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 434645.0 + ] + }, + { + "id": "SF0040", + "constant": "cInSF0040", + "hwAddress": "%E004.0", + "comment": "Bereichshalt UZ0301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180254.6, + 440688.2 + ] + }, + { + "id": "SF0041", + "constant": "cInSF0041", + "hwAddress": "%E004.1", + "comment": "Reset UZ0301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180258.1, + 440421.1 + ] + }, + { + "id": "SF0042", + "constant": "cInSF0042", + "hwAddress": "%E004.2", + "comment": "Bereichshalt UZ0302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 195114.2, + 440848.3 + ] + }, + { + "id": "SF0043", + "constant": "cInSF0043", + "hwAddress": "%E004.3", + "comment": "Reset UZ0302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 195117.7, + 440581.2 + ] + }, + { + "id": "SF0044", + "constant": "cInSF0044", + "hwAddress": "%E004.4", + "comment": "Bereichshalt UZ0303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212642.4, + 440804.7 + ] + }, + { + "id": "SF0045", + "constant": "cInSF0045", + "hwAddress": "%E004.5", + "comment": "Reset UZ0303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212642.4, + 440534.7 + ] + }, + { + "id": "SF0046", + "constant": "cInSF0046", + "hwAddress": "%E004.6", + "comment": "Bereichshalt UZ0304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 230317.3, + 440687.1 + ] + }, + { + "id": "SF0047", + "constant": "cInSF0047", + "hwAddress": "%E004.7", + "comment": "Reset UZ0304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 230317.3, + 440417.1 + ] + }, + { + "id": "SF0050", + "constant": "cInSF0050", + "hwAddress": "%E005.0", + "comment": "Bereichshalt UZ0305", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 183867.3, + 439514.4 + ] + }, + { + "id": "SF0051", + "constant": "cInSF0051", + "hwAddress": "%E005.1", + "comment": "Reset UZ0305", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 183867.3, + 439244.4 + ] + }, + { + "id": "SF0052", + "constant": "cInSF0052", + "hwAddress": "%E005.2", + "comment": "Bereichshalt UZ0306", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199696.5, + 439456.9 + ] + }, + { + "id": "SF0053", + "constant": "cInSF0053", + "hwAddress": "%E005.3", + "comment": "Reset UZ0306", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199696.5, + 439198.9 + ] + }, + { + "id": "SF0054", + "constant": "cInSF0054", + "hwAddress": "%E005.4", + "comment": "Bereichshalt UZ0307", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217447.0, + 439434.8 + ] + }, + { + "id": "SF0055", + "constant": "cInSF0055", + "hwAddress": "%E005.5", + "comment": "Reset UZ0307", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217447.0, + 439164.8 + ] + }, + { + "id": "SF0056", + "constant": "cInSF0056", + "hwAddress": "%E005.6", + "comment": "Bereichshalt UZ0308", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234637.1, + 438966.0 + ] + }, + { + "id": "SF0057", + "constant": "cInSF0057", + "hwAddress": "%E005.7", + "comment": "Reset UZ0308", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234637.1, + 438696.0 + ] + }, + { + "id": "FC0060", + "constant": "cInFC0060", + "hwAddress": "%E006.0", + "comment": "MSS ausgelöst FC0060 (KR-M2103)", + "role": "motorProtection", + "unit": "M2103", + "cabinet": null, + "pos": [ + 252775.2, + 429330.1 + ] + }, + { + "id": "FC0061", + "constant": "cInFC0061", + "hwAddress": "%E006.1", + "comment": "MSS ausgelöst FC0061 (KR-M2104)", + "role": "motorProtection", + "unit": "M2104", + "cabinet": null, + "pos": [ + 252775.2, + 429060.1 + ] + }, + { + "id": "FC0062", + "constant": "cInFC0062", + "hwAddress": "%E006.2", + "comment": "MSS ausgelöst FC0062 (KR-M2201)", + "role": "motorProtection", + "unit": "M2201", + "cabinet": null, + "pos": [ + 252775.2, + 428790.1 + ] + }, + { + "id": "FC0063", + "constant": "cInFC0063", + "hwAddress": "%E006.3", + "comment": "MSS ausgelöst FC0063 (KR-M2202)", + "role": "motorProtection", + "unit": "M2202", + "cabinet": null, + "pos": [ + 252775.2, + 428520.1 + ] + }, + { + "id": "FC0064", + "constant": "cInFC0064", + "hwAddress": "%E006.4", + "comment": "MSS ausgelöst FC0064 (CV-M2205)", + "role": "motorProtection", + "unit": "M2205", + "cabinet": null, + "pos": [ + 252775.2, + 428250.1 + ] + }, + { + "id": "FC0065", + "constant": "cInFC0065", + "hwAddress": "%E006.5", + "comment": "MSS ausgelöst FC0065 (CV-M2206)", + "role": "motorProtection", + "unit": "M2206", + "cabinet": null, + "pos": [ + 252775.2, + 427980.1 + ] + }, + { + "id": "FC0066", + "constant": "cInFC0066", + "hwAddress": "%E006.6", + "comment": "MSS ausgelöst FC0066 (CV-M2207)", + "role": "motorProtection", + "unit": "M2207", + "cabinet": null, + "pos": [ + 252775.2, + 427710.1 + ] + }, + { + "id": "FC0067", + "constant": "cInFC0067", + "hwAddress": "%E006.7", + "comment": "MSS ausgelöst FC0067 (CV-M2208)", + "role": "motorProtection", + "unit": "M2208", + "cabinet": null, + "pos": [ + 252775.2, + 427440.1 + ] + }, + { + "id": "FC0070", + "constant": "cInFC0070", + "hwAddress": "%E007.0", + "comment": "MSS ausgelöst FC0070 (CV-M2109)", + "role": "motorProtection", + "unit": "M2109", + "cabinet": null, + "pos": [ + 255200.1, + 429330.1 + ] + }, + { + "id": "FC0071", + "constant": "cInFC0071", + "hwAddress": "%E007.1", + "comment": "MSS ausgelöst FC0071 (KR-M2110)", + "role": "motorProtection", + "unit": "M2110", + "cabinet": null, + "pos": [ + 255200.1, + 429060.1 + ] + }, + { + "id": "FC0072", + "constant": "cInFC0072", + "hwAddress": "%E007.2", + "comment": "MSS ausgelöst FC0072 (KR-M2112)", + "role": "motorProtection", + "unit": "M2112", + "cabinet": null, + "pos": [ + 255200.1, + 428790.1 + ] + }, + { + "id": "FC0073", + "constant": "cInFC0073", + "hwAddress": "%E007.3", + "comment": "MSS ausgelöst FC0073 (CV-M2111)", + "role": "motorProtection", + "unit": "M2111", + "cabinet": null, + "pos": [ + 255200.1, + 428520.1 + ] + }, + { + "id": "FC0074", + "constant": "cInFC0074", + "hwAddress": "%E007.4", + "comment": "MSS ausgelöst FC0074 (CV-M4101)", + "role": "motorProtection", + "unit": "M4101", + "cabinet": null, + "pos": [ + 255201.7, + 428251.6 + ] + }, + { + "id": "FC0075", + "constant": "cInFC0075", + "hwAddress": "%E007.5", + "comment": "MSS ausgelöst FC0075 (CV-M4201)", + "role": "motorProtection", + "unit": "M4201", + "cabinet": null, + "pos": [ + 255200.1, + 427980.1 + ] + }, + { + "id": "SF0080", + "constant": "cInSF0080", + "hwAddress": "%E008.0", + "comment": "Bereichshalt UZ0309", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245225.9, + 445839.8 + ] + }, + { + "id": "SF0081", + "constant": "cInSF0081", + "hwAddress": "%E008.1", + "comment": "Reset UZ0309", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245225.9, + 445569.8 + ] + }, + { + "id": "SF0082", + "constant": "cInSF0082", + "hwAddress": "%E008.2", + "comment": "Bereichshalt UZ0310", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245462.7, + 432894.4 + ] + }, + { + "id": "SF0083", + "constant": "cInSF0083", + "hwAddress": "%E008.3", + "comment": "Reset UZ0310", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245462.7, + 432624.4 + ] + }, + { + "id": "SF0084", + "constant": "cInSF0084", + "hwAddress": "%E008.4", + "comment": "Bereichshalt UZ0311", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 253860.3, + 450759.7 + ] + }, + { + "id": "SF0085", + "constant": "cInSF0085", + "hwAddress": "%E008.5", + "comment": "Reset UZ0311", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 253860.3, + 450489.7 + ] + }, + { + "id": "SF0086", + "constant": "cInSF0086", + "hwAddress": "%E008.6", + "comment": "Bereichshalt UZ0312", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 275042.4, + 449559.4 + ] + }, + { + "id": "SF0087", + "constant": "cInSF0087", + "hwAddress": "%E008.7", + "comment": "Reset UZ0312", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 275042.4, + 449289.4 + ] + }, + { + "id": "FC0090", + "constant": "cInFC0090", + "hwAddress": "%E009.0", + "comment": "MSS ausgelöst FC0090 (CV-M4102)", + "role": "motorProtection", + "unit": "M4102", + "cabinet": null, + "pos": [ + 255200.1, + 427671.4 + ] + }, + { + "id": "FC0091", + "constant": "cInFC0091", + "hwAddress": "%E009.1", + "comment": "MSS ausgelöst FC0091 (CV-M4202)", + "role": "motorProtection", + "unit": "M4202", + "cabinet": null, + "pos": [ + 255200.1, + 427401.4 + ] + }, + { + "id": "FC0092", + "constant": "cInFC0092", + "hwAddress": "%E009.2", + "comment": "MSS ausgelöst FC0092 (CV-M4301)", + "role": "motorProtection", + "unit": "M4301", + "cabinet": null, + "pos": [ + 255208.1, + 427138.7 + ] + }, + { + "id": "FC0093", + "constant": "cInFC0093", + "hwAddress": "%E009.3", + "comment": "MSS ausgelöst FC0093 (CV-M4401)", + "role": "motorProtection", + "unit": "M4401", + "cabinet": null, + "pos": [ + 255200.4, + 426860.3 + ] + }, + { + "id": "DI0100", + "constant": "cInDI0100", + "hwAddress": "%E010.0", + "comment": "Meldekontakt 400V Motor+Bremse", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 460611.8 + ] + }, + { + "id": "DI0101", + "constant": "cInDI0101", + "hwAddress": "%E010.1", + "comment": "Vorsicherung 24V OK (FC101)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 460341.8 + ] + }, + { + "id": "DI0102", + "constant": "cInDI0102", + "hwAddress": "%E010.2", + "comment": "Vorsicherung 24V OK (FC102)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 460071.8 + ] + }, + { + "id": "DI0103", + "constant": "cInDI0103", + "hwAddress": "%E010.3", + "comment": "Vorsicherung 24V OK (FC103)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 459801.8 + ] + }, + { + "id": "DI0106", + "constant": "cInDI0106", + "hwAddress": "%E010.6", + "comment": "Feedback Hauptschütze aktiv (QA0920/QA0921)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 459129.3 + ] + }, + { + "id": "BP0107", + "constant": "cInBP0107", + "hwAddress": "%E010.7", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UC031", + "pos": [ + 204336.6, + 460237.6 + ] + }, + { + "id": "DI0114", + "constant": "cInDI0114", + "hwAddress": "%E011.4", + "comment": "Feedback Koppelrelais E-Stop-IF (QA0922/QA0923)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 458249.3 + ] + }, + { + "id": "SF0117", + "constant": "cInSF0117", + "hwAddress": "%E011.7", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 462772.3 + ] + }, + { + "id": "SF0120", + "constant": "cInSF0120", + "hwAddress": "%E012.0", + "comment": "Bereichshalt UZ3101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181453.1, + 460377.0 + ] + }, + { + "id": "SF0121", + "constant": "cInSF0121", + "hwAddress": "%E012.1", + "comment": "Reset UZ3101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181453.1, + 460107.0 + ] + }, + { + "id": "SF0122", + "constant": "cInSF0122", + "hwAddress": "%E012.2", + "comment": "Bereichshalt UZ3102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200226.3, + 460430.9 + ] + }, + { + "id": "SF0123", + "constant": "cInSF0123", + "hwAddress": "%E012.3", + "comment": "Reset UZ3102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200226.3, + 460160.9 + ] + }, + { + "id": "SF0124", + "constant": "cInSF0124", + "hwAddress": "%E012.4", + "comment": "Bereichshalt UZ3103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211815.3, + 460471.2 + ] + }, + { + "id": "SF0125", + "constant": "cInSF0125", + "hwAddress": "%E012.5", + "comment": "Reset UZ3103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211815.3, + 460201.2 + ] + }, + { + "id": "SF0126", + "constant": "cInSF0126", + "hwAddress": "%E012.6", + "comment": "Bereichshalt UZ3104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234665.5, + 460391.4 + ] + }, + { + "id": "SF0127", + "constant": "cInSF0127", + "hwAddress": "%E012.7", + "comment": "Reset UZ3104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234665.5, + 460121.4 + ] + }, + { + "id": "FC0140", + "constant": "cInFC0140", + "hwAddress": "%E014.0", + "comment": "MSS ausgelöst FC0140 (KR-M2101)", + "role": "motorProtection", + "unit": "M2101", + "cabinet": null, + "pos": [ + 252810.4, + 456484.7 + ] + }, + { + "id": "FC0141", + "constant": "cInFC0141", + "hwAddress": "%E014.1", + "comment": "MSS ausgelöst FC0141 (KR-M2102)", + "role": "motorProtection", + "unit": "M2102", + "cabinet": null, + "pos": [ + 252810.4, + 456214.7 + ] + }, + { + "id": "FC0142", + "constant": "cInFC0142", + "hwAddress": "%E014.2", + "comment": "MSS ausgelöst FC0142 (CV-M2105)", + "role": "motorProtection", + "unit": "M2105", + "cabinet": null, + "pos": [ + 252811.4, + 455942.5 + ] + }, + { + "id": "FC0143", + "constant": "cInFC0143", + "hwAddress": "%E014.3", + "comment": "MSS ausgelöst FC0143 (CV-M2106)", + "role": "motorProtection", + "unit": "M2106", + "cabinet": null, + "pos": [ + 254920.8, + 456484.7 + ] + }, + { + "id": "FC0144", + "constant": "cInFC0144", + "hwAddress": "%E014.4", + "comment": "MSS ausgelöst FC0144 (CV-M2107)", + "role": "motorProtection", + "unit": "M2107", + "cabinet": null, + "pos": [ + 254920.8, + 456204.7 + ] + }, + { + "id": "FC0145", + "constant": "cInFC0145", + "hwAddress": "%E014.5", + "comment": "MSS ausgelöst FC0145 (CV-M2108)", + "role": "motorProtection", + "unit": "M2108", + "cabinet": null, + "pos": [ + 254920.8, + 455944.7 + ] + }, + { + "id": "DI0160", + "constant": "cInDI0160", + "hwAddress": "%E016.0", + "comment": "Meldekontakt 400V Motor+Bremse", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 420574.2 + ] + }, + { + "id": "DI0161", + "constant": "cInDI0161", + "hwAddress": "%E016.1", + "comment": "Vorsicherung 24V OK (FC161)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 420304.2 + ] + }, + { + "id": "DI0162", + "constant": "cInDI0162", + "hwAddress": "%E016.2", + "comment": "Vorsicherung 24V OK (FC162)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 420034.2 + ] + }, + { + "id": "DI0163", + "constant": "cInDI0163", + "hwAddress": "%E016.3", + "comment": "Vorsicherung 24V OK (FC163)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 419764.2 + ] + }, + { + "id": "DI0164", + "constant": "cInDI0164", + "hwAddress": "%E016.4", + "comment": "Vorsicherung 24V OK (FC164)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 419494.2 + ] + }, + { + "id": "DI0165", + "constant": "cInDI0165", + "hwAddress": "%E016.5", + "comment": "Vorsicherung 24V OK (FC165)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 419224.2 + ] + }, + { + "id": "DI0166", + "constant": "cInDI0166", + "hwAddress": "%E016.6", + "comment": "Feedback Hauptschütze aktiv (QA1230/QA1231)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 418538.2 + ] + }, + { + "id": "BP0167", + "constant": "cInBP0167", + "hwAddress": "%E016.7", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UC032", + "pos": [ + 215427.0, + 420034.4 + ] + }, + { + "id": "DI0174", + "constant": "cInDI0174", + "hwAddress": "%E017.4", + "comment": "Feedback Koppelrelais E-Stop-IF (QA1232/QA1233)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 417668.8 + ] + }, + { + "id": "SF0177", + "constant": "cInSF0177", + "hwAddress": "%E017.7", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 423004.2 + ] + }, + { + "id": "SF0180", + "constant": "cInSF0180", + "hwAddress": "%E018.0", + "comment": "Bereichshalt UZ3201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181391.0, + 421062.6 + ] + }, + { + "id": "SF0181", + "constant": "cInSF0181", + "hwAddress": "%E018.1", + "comment": "Reset UZ3201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181394.5, + 420795.5 + ] + }, + { + "id": "SF0182", + "constant": "cInSF0182", + "hwAddress": "%E018.2", + "comment": "Bereichshalt UZ3202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 421091.5 + ] + }, + { + "id": "SF0183", + "constant": "cInSF0183", + "hwAddress": "%E018.3", + "comment": "Reset UZ3202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 420828.9 + ] + }, + { + "id": "SF0184", + "constant": "cInSF0184", + "hwAddress": "%E018.4", + "comment": "Bereichshalt UZ3203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 421316.7 + ] + }, + { + "id": "SF0185", + "constant": "cInSF0185", + "hwAddress": "%E018.5", + "comment": "Reset UZ3203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 421046.7 + ] + }, + { + "id": "SF0186", + "constant": "cInSF0186", + "hwAddress": "%E018.6", + "comment": "Bereichshalt UZ3204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 230042.3, + 420941.5 + ] + }, + { + "id": "SF0187", + "constant": "cInSF0187", + "hwAddress": "%E018.7", + "comment": "Reset UZ3204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 230042.3, + 420671.5 + ] + }, + { + "id": "SF0190", + "constant": "cInSF0190", + "hwAddress": "%E019.0", + "comment": "Bereichshalt UZ3205", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181394.5, + 418943.9 + ] + }, + { + "id": "SF0191", + "constant": "cInSF0191", + "hwAddress": "%E019.1", + "comment": "Reset UZ3205", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181394.5, + 418673.9 + ] + }, + { + "id": "SF0192", + "constant": "cInSF0192", + "hwAddress": "%E019.2", + "comment": "Bereichshalt UZ3206", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 418986.7 + ] + }, + { + "id": "SF0193", + "constant": "cInSF0193", + "hwAddress": "%E019.3", + "comment": "Reset UZ3206", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 418716.7 + ] + }, + { + "id": "SF0194", + "constant": "cInSF0194", + "hwAddress": "%E019.4", + "comment": "Bereichshalt UZ3207", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 418989.1 + ] + }, + { + "id": "SF0195", + "constant": "cInSF0195", + "hwAddress": "%E019.5", + "comment": "Reset UZ3207", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 418708.0 + ] + }, + { + "id": "SF0196", + "constant": "cInSF0196", + "hwAddress": "%E019.6", + "comment": "Bereichshalt UZ3208", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234637.1, + 418607.9 + ] + }, + { + "id": "SF0197", + "constant": "cInSF0197", + "hwAddress": "%E019.7", + "comment": "Reset UZ3208", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234637.1, + 418337.9 + ] + }, + { + "id": "FC0200", + "constant": "cInFC0200", + "hwAddress": "%E020.0", + "comment": "MSS ausgelöst FC0200 (KR-M2203)", + "role": "motorProtection", + "unit": "M2203", + "cabinet": null, + "pos": [ + 252692.4, + 415790.7 + ] + }, + { + "id": "FC0201", + "constant": "cInFC0201", + "hwAddress": "%E020.1", + "comment": "MSS ausgelöst FC0201 (KR-M0201)", + "role": "motorProtection", + "unit": "M0201", + "cabinet": null, + "pos": [ + 252691.8, + 415520.7 + ] + }, + { + "id": "FC0202", + "constant": "cInFC0202", + "hwAddress": "%E020.2", + "comment": "MSS ausgelöst FC0202 (KR-M2301)", + "role": "motorProtection", + "unit": "M2301", + "cabinet": null, + "pos": [ + 252691.8, + 415250.7 + ] + }, + { + "id": "FC0203", + "constant": "cInFC0203", + "hwAddress": "%E020.3", + "comment": "MSS ausgelöst FC0203 (KR-M2302)", + "role": "motorProtection", + "unit": "M2302", + "cabinet": null, + "pos": [ + 252691.8, + 414980.7 + ] + }, + { + "id": "FC0204", + "constant": "cInFC0204", + "hwAddress": "%E020.4", + "comment": "MSS ausgelöst FC0204 (CV-M2309)", + "role": "motorProtection", + "unit": "M2309", + "cabinet": null, + "pos": [ + 252691.8, + 414710.7 + ] + }, + { + "id": "FC0205", + "constant": "cInFC0205", + "hwAddress": "%E020.5", + "comment": "MSS ausgelöst FC0205 (CV-M2209)", + "role": "motorProtection", + "unit": "M2209", + "cabinet": null, + "pos": [ + 252691.8, + 414440.7 + ] + }, + { + "id": "DI0220", + "constant": "cInDI0220", + "hwAddress": "%E022.0", + "comment": "Meldekontakt 400V Motor+Bremse", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 402382.5 + ] + }, + { + "id": "DI0221", + "constant": "cInDI0221", + "hwAddress": "%E022.1", + "comment": "Vorsicherung 24V OK (FC221)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 402112.5 + ] + }, + { + "id": "DI0222", + "constant": "cInDI0222", + "hwAddress": "%E022.2", + "comment": "Vorsicherung 24V OK (FC222)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 401842.5 + ] + }, + { + "id": "DI0223", + "constant": "cInDI0223", + "hwAddress": "%E022.3", + "comment": "Vorsicherung 24V OK (FC223)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 401572.5 + ] + }, + { + "id": "DI0226", + "constant": "cInDI0226", + "hwAddress": "%E022.6", + "comment": "Feedback Hauptschütze aktiv (QA1540/QA1541)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 400976.3 + ] + }, + { + "id": "BP0227", + "constant": "cInBP0227", + "hwAddress": "%E022.7", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UC033", + "pos": [ + 204321.3, + 397561.2 + ] + }, + { + "id": "DI0234", + "constant": "cInDI0234", + "hwAddress": "%E023.4", + "comment": "Feedback Koppelrelais E-Stop-IF (QA1542/QA1543)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 400101.0 + ] + }, + { + "id": "SF0237", + "constant": "cInSF0237", + "hwAddress": "%E023.7", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 404672.6 + ] + }, + { + "id": "SF0240", + "constant": "cInSF0240", + "hwAddress": "%E024.0", + "comment": "Bereichshalt UZ3301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181403.6, + 397644.3 + ] + }, + { + "id": "SF0241", + "constant": "cInSF0241", + "hwAddress": "%E024.1", + "comment": "Reset UZ3301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181407.1, + 397377.2 + ] + }, + { + "id": "SF0242", + "constant": "cInSF0242", + "hwAddress": "%E024.2", + "comment": "Bereichshalt UZ3302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200233.2, + 397725.2 + ] + }, + { + "id": "SF0243", + "constant": "cInSF0243", + "hwAddress": "%E024.3", + "comment": "Reset UZ3302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200233.2, + 397455.2 + ] + }, + { + "id": "SF0244", + "constant": "cInSF0244", + "hwAddress": "%E024.4", + "comment": "Bereichshalt UZ3303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212835.4, + 397421.5 + ] + }, + { + "id": "SF0245", + "constant": "cInSF0245", + "hwAddress": "%E024.5", + "comment": "Reset UZ3303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212835.4, + 397151.5 + ] + }, + { + "id": "SF0246", + "constant": "cInSF0246", + "hwAddress": "%E024.6", + "comment": "Bereichshalt UZ3304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235073.6, + 397625.2 + ] + }, + { + "id": "SF0247", + "constant": "cInSF0247", + "hwAddress": "%E024.7", + "comment": "Reset UZ3304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235073.6, + 397355.2 + ] + }, + { + "id": "FC0260", + "constant": "cInFC0260", + "hwAddress": "%E026.0", + "comment": "MSS ausgelöst FC0260 (KR-M2303)", + "role": "motorProtection", + "unit": "M2303", + "cabinet": null, + "pos": [ + 252692.4, + 398454.8 + ] + }, + { + "id": "FC0261", + "constant": "cInFC0261", + "hwAddress": "%E026.1", + "comment": "MSS ausgelöst FC0261 (KR-M2304)", + "role": "motorProtection", + "unit": "M2304", + "cabinet": null, + "pos": [ + 252692.4, + 398184.8 + ] + }, + { + "id": "FC0262", + "constant": "cInFC0262", + "hwAddress": "%E026.2", + "comment": "MSS ausgelöst FC0262 (CV-M2305)", + "role": "motorProtection", + "unit": "M2305", + "cabinet": null, + "pos": [ + 252692.4, + 397907.9 + ] + }, + { + "id": "FC0263", + "constant": "cInFC0263", + "hwAddress": "%E026.3", + "comment": "MSS ausgelöst FC0263 (CV-M2306)", + "role": "motorProtection", + "unit": "M2306", + "cabinet": null, + "pos": [ + 252692.4, + 397644.8 + ] + }, + { + "id": "FC0264", + "constant": "cInFC0264", + "hwAddress": "%E026.4", + "comment": "MSS ausgelöst FC0264 (CV-M2307)", + "role": "motorProtection", + "unit": "M2307", + "cabinet": null, + "pos": [ + 252692.4, + 397374.8 + ] + }, + { + "id": "FC0265", + "constant": "cInFC0265", + "hwAddress": "%E026.5", + "comment": "MSS ausgelöst FC0265 (CV-M2308)", + "role": "motorProtection", + "unit": "M2308", + "cabinet": null, + "pos": [ + 252692.4, + 397104.8 + ] + }, + { + "id": "SF0400", + "constant": "cInSF0400", + "hwAddress": "%E040.0", + "comment": "Not Halt Kanal 1 UH03", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 439998.2 + ] + }, + { + "id": "SF0401", + "constant": "cInSF0401", + "hwAddress": "%E040.1", + "comment": "Not Halt Kanal 1 UZ0301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180258.1, + 440131.1 + ] + }, + { + "id": "SF0402", + "constant": "cInSF0402", + "hwAddress": "%E040.2", + "comment": "Not Halt Kanal 1 UZ0302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 195117.7, + 440222.5 + ] + }, + { + "id": "SF0403", + "constant": "cInSF0403", + "hwAddress": "%E040.3", + "comment": "Not Halt Kanal 1 UZ0303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212646.2, + 440226.3 + ] + }, + { + "id": "SF0404", + "constant": "cInSF0404", + "hwAddress": "%E040.4", + "comment": "Not Halt Kanal 2 UH03", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.6, + 439728.2 + ] + }, + { + "id": "SF0405", + "constant": "cInSF0405", + "hwAddress": "%E040.5", + "comment": "Not Halt Kanal 2 UZ0301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 180258.1, + 439861.1 + ] + }, + { + "id": "SF0406", + "constant": "cInSF0406", + "hwAddress": "%E040.6", + "comment": "Not Halt Kanal 2 UZ0302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 195117.7, + 439952.5 + ] + }, + { + "id": "SF0407", + "constant": "cInSF0407", + "hwAddress": "%E040.7", + "comment": "Not Halt Kanal 2 UZ0303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212646.2, + 439956.3 + ] + }, + { + "id": "SF0470", + "constant": "cInSF0470", + "hwAddress": "%E047.0", + "comment": "Not Halt Kanal 1 UZ0304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 230317.3, + 440127.1 + ] + }, + { + "id": "SF0471", + "constant": "cInSF0471", + "hwAddress": "%E047.1", + "comment": "Not Halt Kanal 1 UZ0309", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245225.9, + 445269.6 + ] + }, + { + "id": "SF0472", + "constant": "cInSF0472", + "hwAddress": "%E047.2", + "comment": "Not Halt Kanal 1 UZ0310", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245466.9, + 432324.2 + ] + }, + { + "id": "SF0474", + "constant": "cInSF0474", + "hwAddress": "%E047.4", + "comment": "Not Halt Kanal 2 UZ0304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 230317.3, + 439857.1 + ] + }, + { + "id": "SF0475", + "constant": "cInSF0475", + "hwAddress": "%E047.5", + "comment": "Not Halt Kanal 2 UZ0309", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245225.9, + 444999.6 + ] + }, + { + "id": "SF0476", + "constant": "cInSF0476", + "hwAddress": "%E047.6", + "comment": "Not Halt Kanal 2 UZ0310", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 245466.9, + 432054.2 + ] + }, + { + "id": "SF0541", + "constant": "cInSF0541", + "hwAddress": "%E054.1", + "comment": "Not Halt Schnittstelle CH1 (UC072)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.1, + 431960.7 + ] + }, + { + "id": "SF0542", + "constant": "cInSF0542", + "hwAddress": "%E054.2", + "comment": "Not Halt Schnittstelle CH2 (von UH02)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.1, + 431690.7 + ] + }, + { + "id": "SF0545", + "constant": "cInSF0545", + "hwAddress": "%E054.5", + "comment": "Not Halt Schnittstelle CH1 (UC072)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.1, + 430467.1 + ] + }, + { + "id": "SF0546", + "constant": "cInSF0546", + "hwAddress": "%E054.6", + "comment": "Not Halt Schnittstelle CH2 (zu UH02)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252793.1, + 430197.1 + ] + }, + { + "id": "SF0710", + "constant": "cInSF0710", + "hwAddress": "%E071.0", + "comment": "Not Halt Kanal 1 UC031", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 461692.3 + ] + }, + { + "id": "SF0711", + "constant": "cInSF0711", + "hwAddress": "%E071.1", + "comment": "Not Halt Kanal 1 UZ3101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181453.1, + 459816.6 + ] + }, + { + "id": "SF0712", + "constant": "cInSF0712", + "hwAddress": "%E071.2", + "comment": "Not Halt Kanal 1 UZ3102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200226.3, + 459870.9 + ] + }, + { + "id": "SF0713", + "constant": "cInSF0713", + "hwAddress": "%E071.3", + "comment": "Not Halt Kanal 1 UZ3103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211815.3, + 459911.2 + ] + }, + { + "id": "SF0714", + "constant": "cInSF0714", + "hwAddress": "%E071.4", + "comment": "Not Halt Kanal 2 UC031", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 461422.3 + ] + }, + { + "id": "SF0715", + "constant": "cInSF0715", + "hwAddress": "%E071.5", + "comment": "Not Halt Kanal 2 UZ3101", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181453.1, + 459546.6 + ] + }, + { + "id": "SF0716", + "constant": "cInSF0716", + "hwAddress": "%E071.6", + "comment": "Not Halt Kanal 2 UZ3102", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200226.3, + 459600.9 + ] + }, + { + "id": "SF0717", + "constant": "cInSF0717", + "hwAddress": "%E071.7", + "comment": "Not Halt Kanal 2 UZ3103", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211815.3, + 459641.2 + ] + }, + { + "id": "SF0780", + "constant": "cInSF0780", + "hwAddress": "%E078.0", + "comment": "Not Halt Kanal 1 UZ3104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234665.5, + 459821.2 + ] + }, + { + "id": "SF0781", + "constant": "cInSF0781", + "hwAddress": "%E078.1", + "comment": "Not Halt Schnittstelle CH1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 457669.5 + ] + }, + { + "id": "SF0784", + "constant": "cInSF0784", + "hwAddress": "%E078.4", + "comment": "Not Halt Kanal 2 UZ3104", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234665.5, + 459551.2 + ] + }, + { + "id": "SF0785", + "constant": "cInSF0785", + "hwAddress": "%E078.5", + "comment": "Not Halt Schnittstelle CH2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252828.8, + 457399.5 + ] + }, + { + "id": "SF1020", + "constant": "cInSF1020", + "hwAddress": "%E102.0", + "comment": "Not Halt Kanal 1 UC032", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 421902.3 + ] + }, + { + "id": "SF1021", + "constant": "cInSF1021", + "hwAddress": "%E102.1", + "comment": "Not Halt Kanal 1 UZ3201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181394.5, + 420505.5 + ] + }, + { + "id": "SF1022", + "constant": "cInSF1022", + "hwAddress": "%E102.2", + "comment": "Not Halt Kanal 1 UZ3202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 420531.5 + ] + }, + { + "id": "SF1023", + "constant": "cInSF1023", + "hwAddress": "%E102.3", + "comment": "Not Halt Kanal 1 UZ3203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 420756.7 + ] + }, + { + "id": "SF1024", + "constant": "cInSF1024", + "hwAddress": "%E102.4", + "comment": "Not Halt Kanal 2 UC032", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 421632.3 + ] + }, + { + "id": "SF1025", + "constant": "cInSF1025", + "hwAddress": "%E102.5", + "comment": "Not Halt Kanal 2 UZ3201", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181394.5, + 420235.5 + ] + }, + { + "id": "SF1026", + "constant": "cInSF1026", + "hwAddress": "%E102.6", + "comment": "Not Halt Kanal 2 UZ3202", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199578.6, + 420261.5 + ] + }, + { + "id": "SF1027", + "constant": "cInSF1027", + "hwAddress": "%E102.7", + "comment": "Not Halt Kanal 2 UZ3203", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211891.9, + 420486.7 + ] + }, + { + "id": "SF1090", + "constant": "cInSF1090", + "hwAddress": "%E109.0", + "comment": "Not Halt Kanal 1 UZ3204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 230042.3, + 420273.2 + ] + }, + { + "id": "SF1091", + "constant": "cInSF1091", + "hwAddress": "%E109.1", + "comment": "Not Halt Schnittstelle CH1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 417068.2 + ] + }, + { + "id": "SF1094", + "constant": "cInSF1094", + "hwAddress": "%E109.4", + "comment": "Not Halt Kanal 2 UZ3204", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 230042.3, + 420003.2 + ] + }, + { + "id": "SF1095", + "constant": "cInSF1095", + "hwAddress": "%E109.5", + "comment": "Not Halt Schnittstelle CH2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 416798.2 + ] + }, + { + "id": "SF1330", + "constant": "cInSF1330", + "hwAddress": "%E133.0", + "comment": "Not Halt Kanal 1 UC033", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 403570.7 + ] + }, + { + "id": "SF1331", + "constant": "cInSF1331", + "hwAddress": "%E133.1", + "comment": "Not Halt Kanal 1 UZ3301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181407.1, + 397087.2 + ] + }, + { + "id": "SF1332", + "constant": "cInSF1332", + "hwAddress": "%E133.2", + "comment": "Not Halt Kanal 1 UZ3302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200233.2, + 397165.2 + ] + }, + { + "id": "SF1333", + "constant": "cInSF1333", + "hwAddress": "%E133.3", + "comment": "Not Halt Kanal 1 UZ3303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212835.4, + 396827.7 + ] + }, + { + "id": "SF1334", + "constant": "cInSF1334", + "hwAddress": "%E133.4", + "comment": "Not Halt Kanal 2 UC033", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 403300.7 + ] + }, + { + "id": "SF1335", + "constant": "cInSF1335", + "hwAddress": "%E133.5", + "comment": "Not Halt Kanal 2 UZ3301", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 181407.1, + 396817.2 + ] + }, + { + "id": "SF1336", + "constant": "cInSF1336", + "hwAddress": "%E133.6", + "comment": "Not Halt Kanal 2 UZ3302", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 200233.2, + 396895.2 + ] + }, + { + "id": "SF1337", + "constant": "cInSF1337", + "hwAddress": "%E133.7", + "comment": "Not Halt Kanal 2 UZ3303", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 212835.4, + 396557.7 + ] + }, + { + "id": "SF1400", + "constant": "cInSF1400", + "hwAddress": "%E140.0", + "comment": "Not Halt Kanal 1 UZ3304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235073.6, + 397065.2 + ] + }, + { + "id": "SF1401", + "constant": "cInSF1401", + "hwAddress": "%E140.1", + "comment": "Not Halt Schnittstelle CH1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 399528.9 + ] + }, + { + "id": "SF1404", + "constant": "cInSF1404", + "hwAddress": "%E140.4", + "comment": "Not Halt Kanal 2 UZ3304", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235073.6, + 396795.2 + ] + }, + { + "id": "SF1405", + "constant": "cInSF1405", + "hwAddress": "%E140.5", + "comment": "Not Halt Schnittstelle CH2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 252710.8, + 399258.9 + ] + }, + { + "id": "SF1470", + "constant": "cInSF1470", + "hwAddress": "%E147.0", + "comment": "Not Halt Kanal 1 UZ0305", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 183867.3, + 438954.4 + ] + }, + { + "id": "SF1471", + "constant": "cInSF1471", + "hwAddress": "%E147.1", + "comment": "Not Halt Kanal 1 UZ0306", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199696.5, + 438896.9 + ] + }, + { + "id": "SF1472", + "constant": "cInSF1472", + "hwAddress": "%E147.2", + "comment": "Not Halt Kanal 1 UZ0307", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217447.0, + 438874.8 + ] + }, + { + "id": "SF1473", + "constant": "cInSF1473", + "hwAddress": "%E147.3", + "comment": "Not Halt Kanal 1 UZ0308", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234637.1, + 438406.0 + ] + }, + { + "id": "SF1474", + "constant": "cInSF1474", + "hwAddress": "%E147.4", + "comment": "Not Halt Kanal 2 UZ0305", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 183867.3, + 438684.4 + ] + }, + { + "id": "SF1475", + "constant": "cInSF1475", + "hwAddress": "%E147.5", + "comment": "Not Halt Kanal 2 UZ0306", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 199696.5, + 438626.9 + ] + }, + { + "id": "SF1476", + "constant": "cInSF1476", + "hwAddress": "%E147.6", + "comment": "Not Halt Kanal 2 UZ0307", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217447.0, + 438604.8 + ] + }, + { + "id": "SF1477", + "constant": "cInSF1477", + "hwAddress": "%E147.7", + "comment": "Not Halt Kanal 2 UZ0308", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 234637.1, + 438136.0 + ] + }, + { + "id": "BG3000", + "constant": "cInBG3000", + "hwAddress": "%E300.0", + "comment": "in Separator 2 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 187132.0, + 457871.7 + ] + }, + { + "id": "BG3001", + "constant": "cInBG3001", + "hwAddress": "%E300.1", + "comment": "Pin Abfrage (KR-M2101 ) Block 2.1.1", + "role": "sensorPinQuery", + "unit": "M2101", + "cabinet": "UC3101", + "pos": [ + 187137.4, + 458835.0 + ] + }, + { + "id": "BG3002", + "constant": "cInBG3002", + "hwAddress": "%E300.2", + "comment": "Prüfung MT Pos.1 (KR-K2101 Einfahrt Block 2.1.1)", + "role": "sensorPinQuery", + "unit": "K2101", + "cabinet": "UC3101", + "pos": [ + 186658.6, + 459134.2 + ] + }, + { + "id": "BG3003", + "constant": "cInBG3003", + "hwAddress": "%E300.3", + "comment": "Stausensor (KR-M2101)", + "role": "sensorJam", + "unit": "M2101", + "cabinet": "UC3101", + "pos": [ + 187941.8, + 458835.0 + ] + }, + { + "id": "BG3004", + "constant": "cInBG3004", + "hwAddress": "%E300.4", + "comment": "in Separator 1 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 187127.8, + 457279.5 + ] + }, + { + "id": "BG3005", + "constant": "cInBG3005", + "hwAddress": "%E300.5", + "comment": "Stausensor Str.1 (KR-K2105 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K2105", + "cabinet": "UC3101", + "pos": [ + 187126.0, + 456968.4 + ] + }, + { + "id": "BG3006", + "constant": "cInBG3006", + "hwAddress": "%E300.6", + "comment": "Sensor Förderer voll (ILS-CV 2105)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 187126.0, + 456370.0 + ] + }, + { + "id": "BG3007", + "constant": "cInBG3007", + "hwAddress": "%E300.7", + "comment": "Prüfung MT Pos.2 (KR-K2101 Einfahrt Block 2.1.1)", + "role": "sensorWheel", + "unit": "K2101", + "cabinet": "UC1101", + "pos": [ + 341225.8, + 451084.9 + ] + }, + { + "id": "BG3010", + "constant": "cInBG3010", + "hwAddress": "%E301.0", + "comment": "Prüfung MT Pos.3 (KR-K2101 Einfahrt Block 2.1.1)", + "role": "sensorPinQuery", + "unit": "K2101", + "cabinet": "UC3101", + "pos": [ + 178799.9, + 459122.4 + ] + }, + { + "id": "BG3011", + "constant": "cInBG3011", + "hwAddress": "%E301.1", + "comment": "Prüfung MT Pos.4 (KR-K2101 Einfahrt Block 2.1.1)", + "role": "sensorPinQuery", + "unit": "K2101", + "cabinet": "UC3101", + "pos": [ + 175587.3, + 459122.4 + ] + }, + { + "id": "BG3012", + "constant": "cInBG3012", + "hwAddress": "%E301.2", + "comment": "Prüfung MT Pos.5 (KR-K2101 Einfahrt Block 2.1.1)", + "role": "sensorPinQuery", + "unit": "K2101", + "cabinet": "UC3101", + "pos": [ + 172113.1, + 459122.4 + ] + }, + { + "id": "BG3030", + "constant": "cInBG3030", + "hwAddress": "%E303.0", + "comment": "Stausensor Str.1 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 185950.3, + 457695.7 + ] + }, + { + "id": "BG3031", + "constant": "cInBG3031", + "hwAddress": "%E303.1", + "comment": "Stausensor Str.2 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 185150.0, + 457822.3 + ] + }, + { + "id": "BG3032", + "constant": "cInBG3032", + "hwAddress": "%E303.2", + "comment": "Stausensor Str.3 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 184349.9, + 457822.3 + ] + }, + { + "id": "BG3033", + "constant": "cInBG3033", + "hwAddress": "%E303.3", + "comment": "Stausensor Str.4 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 183550.0, + 457822.0 + ] + }, + { + "id": "BG3034", + "constant": "cInBG3034", + "hwAddress": "%E303.4", + "comment": "Stausensor Str.5 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 182749.9, + 457822.3 + ] + }, + { + "id": "BG3035", + "constant": "cInBG3035", + "hwAddress": "%E303.5", + "comment": "Stausensor Str.6 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 181949.9, + 457822.3 + ] + }, + { + "id": "BG3036", + "constant": "cInBG3036", + "hwAddress": "%E303.6", + "comment": "Stausensor Str.7 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 181150.0, + 457822.0 + ] + }, + { + "id": "BG3037", + "constant": "cInBG3037", + "hwAddress": "%E303.7", + "comment": "Stausensor Str.8 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 179149.9, + 457822.3 + ] + }, + { + "id": "BG3040", + "constant": "cInBG3040", + "hwAddress": "%E304.0", + "comment": "Stausensor Str.9 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 178349.9, + 457822.3 + ] + }, + { + "id": "BG3041", + "constant": "cInBG3041", + "hwAddress": "%E304.1", + "comment": "Stausensor Str.10 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 177550.0, + 457822.0 + ] + }, + { + "id": "BG3042", + "constant": "cInBG3042", + "hwAddress": "%E304.2", + "comment": "Stausensor Str.11 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 176749.9, + 457822.3 + ] + }, + { + "id": "BG3043", + "constant": "cInBG3043", + "hwAddress": "%E304.3", + "comment": "Stausensor Str.12 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 175949.9, + 457822.3 + ] + }, + { + "id": "BG3044", + "constant": "cInBG3044", + "hwAddress": "%E304.4", + "comment": "Stausensor Str.13 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 175150.0, + 457822.0 + ] + }, + { + "id": "BG3045", + "constant": "cInBG3045", + "hwAddress": "%E304.5", + "comment": "Stausensor Str.14 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 174000.0, + 457822.3 + ] + }, + { + "id": "BG3046", + "constant": "cInBG3046", + "hwAddress": "%E304.6", + "comment": "Stausensor Str.15 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 173200.0, + 457822.3 + ] + }, + { + "id": "BG3047", + "constant": "cInBG3047", + "hwAddress": "%E304.7", + "comment": "Stausensor Str.16 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 172400.1, + 457822.0 + ] + }, + { + "id": "BG3050", + "constant": "cInBG3050", + "hwAddress": "%E305.0", + "comment": "Stausensor Str.17 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 171600.0, + 457822.3 + ] + }, + { + "id": "BG3051", + "constant": "cInBG3051", + "hwAddress": "%E305.1", + "comment": "Stausensor Str.18 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 170800.0, + 457822.3 + ] + }, + { + "id": "BG3052", + "constant": "cInBG3052", + "hwAddress": "%E305.2", + "comment": "Stausensor Str.19 (Block 2.1.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3101", + "pos": [ + 170000.1, + 457822.0 + ] + }, + { + "id": "BG3060", + "constant": "cInBG3060", + "hwAddress": "%E306.0", + "comment": "in Separator 2 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 204368.7, + 457871.7 + ] + }, + { + "id": "BG3061", + "constant": "cInBG3061", + "hwAddress": "%E306.1", + "comment": "Pin Abfrage (KR-M2101 ) Block 2.1.2", + "role": "sensorPinQuery", + "unit": "M2101", + "cabinet": "UC3102", + "pos": [ + 204081.7, + 458835.0 + ] + }, + { + "id": "BG3062", + "constant": "cInBG3062", + "hwAddress": "%E306.2", + "comment": "Prüfung MT Pos.1 (KR-K2101 Einfahrt Block 2.1.2)", + "role": "sensorPinQuery", + "unit": "K2101", + "cabinet": "UC3102", + "pos": [ + 203729.6, + 459134.2 + ] + }, + { + "id": "BG3063", + "constant": "cInBG3063", + "hwAddress": "%E306.3", + "comment": "Stausensor Str.2 (KR-M2101)", + "role": "sensorJam", + "unit": "M2101", + "cabinet": "UC3102", + "pos": [ + 204280.3, + 459470.5 + ] + }, + { + "id": "BG3064", + "constant": "cInBG3064", + "hwAddress": "%E306.4", + "comment": "in Separator 1 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 204364.4, + 457279.5 + ] + }, + { + "id": "BG3065", + "constant": "cInBG3065", + "hwAddress": "%E306.5", + "comment": "Stausensor Str.1 (KR-K2101 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K2101", + "cabinet": "UC3102", + "pos": [ + 204362.7, + 456968.4 + ] + }, + { + "id": "BG3066", + "constant": "cInBG3066", + "hwAddress": "%E306.6", + "comment": "Sensor Förderer voll (ILS-CV 2106)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 204356.5, + 456371.0 + ] + }, + { + "id": "BG3067", + "constant": "cInBG3067", + "hwAddress": "%E306.7", + "comment": "Prüfung MT Pos.2 (KR-K2101 Einfahrt Block 2.1.2)", + "role": "sensorPinQuery", + "unit": "K2101", + "cabinet": "UC3102", + "pos": [ + 200294.7, + 459122.4 + ] + }, + { + "id": "BG3070", + "constant": "cInBG3070", + "hwAddress": "%E307.0", + "comment": "Prüfung MT Pos.3 (KR-K2101 Einfahrt Block 2.1.2)", + "role": "sensorPinQuery", + "unit": "K2101", + "cabinet": "UC3102", + "pos": [ + 196641.7, + 459124.6 + ] + }, + { + "id": "BG3071", + "constant": "cInBG3071", + "hwAddress": "%E307.1", + "comment": "Prüfung MT Pos.4 (KR-K2101 Einfahrt Block 2.1.2)", + "role": "sensorPinQuery", + "unit": "K2101", + "cabinet": "UC3102", + "pos": [ + 193555.9, + 459122.4 + ] + }, + { + "id": "BG3072", + "constant": "cInBG3072", + "hwAddress": "%E307.2", + "comment": "Prüfung MT Pos.5 (KR-K2101 Einfahrt Block 2.1.2)", + "role": "sensorPinQuery", + "unit": "K2101", + "cabinet": "UC3102", + "pos": [ + 189533.1, + 459122.4 + ] + }, + { + "id": "BG3073", + "constant": "cInBG3073", + "hwAddress": "%E307.3", + "comment": "Stausensor MT vor Pinband (KR-M2101 Block 2.1.2)", + "role": "sensorJam", + "unit": "M2101", + "cabinet": "UC3102", + "pos": [ + 188790.6, + 459122.4 + ] + }, + { + "id": "BG3090", + "constant": "cInBG3090", + "hwAddress": "%E309.0", + "comment": "Stausensor Str.1 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 203150.0, + 457695.7 + ] + }, + { + "id": "BG3091", + "constant": "cInBG3091", + "hwAddress": "%E309.1", + "comment": "Stausensor Str.2 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 202350.0, + 457822.4 + ] + }, + { + "id": "BG3092", + "constant": "cInBG3092", + "hwAddress": "%E309.2", + "comment": "Stausensor Str.3 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 201550.0, + 457822.4 + ] + }, + { + "id": "BG3093", + "constant": "cInBG3093", + "hwAddress": "%E309.3", + "comment": "Stausensor Str.4 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 200750.1, + 457822.1 + ] + }, + { + "id": "BG3094", + "constant": "cInBG3094", + "hwAddress": "%E309.4", + "comment": "Stausensor Str.5 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 199950.0, + 457822.4 + ] + }, + { + "id": "BG3095", + "constant": "cInBG3095", + "hwAddress": "%E309.5", + "comment": "Stausensor Str.6 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 199150.0, + 457822.4 + ] + }, + { + "id": "BG3096", + "constant": "cInBG3096", + "hwAddress": "%E309.6", + "comment": "Stausensor Str.7 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 197950.0, + 457822.4 + ] + }, + { + "id": "BG3097", + "constant": "cInBG3097", + "hwAddress": "%E309.7", + "comment": "Stausensor Str.8 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 197100.2, + 457822.4 + ] + }, + { + "id": "BG3100", + "constant": "cInBG3100", + "hwAddress": "%E310.0", + "comment": "Stausensor Str.9 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 196300.1, + 457822.3 + ] + }, + { + "id": "BG3101", + "constant": "cInBG3101", + "hwAddress": "%E310.1", + "comment": "Stausensor Str.10 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 195500.2, + 457822.0 + ] + }, + { + "id": "BG3102", + "constant": "cInBG3102", + "hwAddress": "%E310.2", + "comment": "Stausensor Str.11 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 194700.1, + 457822.3 + ] + }, + { + "id": "BG3103", + "constant": "cInBG3103", + "hwAddress": "%E310.3", + "comment": "Stausensor Str.12 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 193900.1, + 457822.3 + ] + }, + { + "id": "BG3104", + "constant": "cInBG3104", + "hwAddress": "%E310.4", + "comment": "Stausensor Str.13 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 193100.2, + 457822.0 + ] + }, + { + "id": "BG3105", + "constant": "cInBG3105", + "hwAddress": "%E310.5", + "comment": "Stausensor Str.14 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 191300.0, + 457822.3 + ] + }, + { + "id": "BG3106", + "constant": "cInBG3106", + "hwAddress": "%E310.6", + "comment": "Stausensor Str.15 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 190500.0, + 457822.3 + ] + }, + { + "id": "BG3107", + "constant": "cInBG3107", + "hwAddress": "%E310.7", + "comment": "Stausensor Str.16 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 189700.1, + 457822.0 + ] + }, + { + "id": "BG3110", + "constant": "cInBG3110", + "hwAddress": "%E311.0", + "comment": "Stausensor Str.17 (Block 2.1.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3102", + "pos": [ + 188900.0, + 457822.3 + ] + }, + { + "id": "BG3120", + "constant": "cInBG3120", + "hwAddress": "%E312.0", + "comment": "in Separator 2 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 207564.0, + 457473.8 + ] + }, + { + "id": "BG3121", + "constant": "cInBG3121", + "hwAddress": "%E312.1", + "comment": "Pin Abfrage (KR-M2102 ) Block 2.1.3", + "role": "sensorPinQuery", + "unit": "M2102", + "cabinet": "UC3103", + "pos": [ + 207130.0, + 458839.1 + ] + }, + { + "id": "BG3122", + "constant": "cInBG3122", + "hwAddress": "%E312.2", + "comment": "Prüfung MT Pos.1 (KR-K2102 Einfahrt Block 2.1.3)", + "role": "sensorPinQuery", + "unit": "K2102", + "cabinet": "UC3103", + "pos": [ + 207628.8, + 459134.2 + ] + }, + { + "id": "BG3123", + "constant": "cInBG3123", + "hwAddress": "%E312.3", + "comment": "Stausensor Str.2 (KR-M2102)", + "role": "sensorJam", + "unit": "M2102", + "cabinet": "UC3103", + "pos": [ + 206622.0, + 458127.3 + ] + }, + { + "id": "BG3124", + "constant": "cInBG3124", + "hwAddress": "%E312.4", + "comment": "in Separator 1 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 206614.4, + 457439.4 + ] + }, + { + "id": "BG3125", + "constant": "cInBG3125", + "hwAddress": "%E312.5", + "comment": "Stausensor Str.1 (KR-K2107 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K2107", + "cabinet": "UC3103", + "pos": [ + 206612.7, + 457128.2 + ] + }, + { + "id": "BG3126", + "constant": "cInBG3126", + "hwAddress": "%E312.6", + "comment": "Sensor Förderer voll (ILS-CV 2107)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 206612.7, + 456532.7 + ] + }, + { + "id": "BG3127", + "constant": "cInBG3127", + "hwAddress": "%E312.7", + "comment": "Prüfung MT Pos.2 (KR-K2102 Einfahrt Block 2.1.3)", + "role": "sensorPinQuery", + "unit": "K2102", + "cabinet": "UC3103", + "pos": [ + 211110.0, + 459122.4 + ] + }, + { + "id": "BG3130", + "constant": "cInBG3130", + "hwAddress": "%E313.0", + "comment": "Prüfung MT Pos.3 (KR-K2102 Einfahrt Block 2.1.3)", + "role": "sensorPinQuery", + "unit": "K2102", + "cabinet": "UC3103", + "pos": [ + 214297.6, + 459122.4 + ] + }, + { + "id": "BG3131", + "constant": "cInBG3131", + "hwAddress": "%E313.1", + "comment": "Prüfung MT Pos.4 (KR-K2102 Einfahrt Block 2.1.3)", + "role": "sensorPinQuery", + "unit": "K2102", + "cabinet": "UC3103", + "pos": [ + 218467.0, + 459122.4 + ] + }, + { + "id": "BG3132", + "constant": "cInBG3132", + "hwAddress": "%E313.2", + "comment": "Prüfung MT Pos.5 (KR-K2102 Einfahrt Block 2.1.3)", + "role": "sensorPinQuery", + "unit": "K2102", + "cabinet": "UC3103", + "pos": [ + 221678.7, + 459122.4 + ] + }, + { + "id": "BG3133", + "constant": "cInBG3133", + "hwAddress": "%E313.3", + "comment": "Prüfung MT Pos.6 (KR-K2102 Einfahrt Block 2.1.3)", + "role": "sensorPinQuery", + "unit": "K2102", + "cabinet": "UC3103", + "pos": [ + 225265.9, + 459122.4 + ] + }, + { + "id": "BG3134", + "constant": "cInBG3134", + "hwAddress": "%E313.4", + "comment": "in Separator 3 (KR-M2102 Block 2.1.3)", + "role": "sensorInSep", + "unit": "M2102", + "cabinet": "UC3103", + "pos": [ + 224498.3, + 459859.1 + ] + }, + { + "id": "BG3135", + "constant": "cInBG3135", + "hwAddress": "%E313.5", + "comment": "Stausensor (ILS-CV 1 M1109)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 223253.0, + 460126.4 + ] + }, + { + "id": "BG3136", + "constant": "cInBG3136", + "hwAddress": "%E313.6", + "comment": "Stausensor 1 (KR-M2102)", + "role": "sensorJam", + "unit": "M2102", + "cabinet": "UC3103", + "pos": [ + 222191.5, + 459489.6 + ] + }, + { + "id": "BG3137", + "constant": "cInBG3137", + "hwAddress": "%E313.7", + "comment": "in Separator 4 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 207625.0, + 459467.0 + ] + }, + { + "id": "BG3140", + "constant": "cInBG3140", + "hwAddress": "%E314.0", + "comment": "Stausensor MT vor Pinband (KR-M2102 Block 2.1.3)", + "role": "sensorJam", + "unit": "M2102", + "cabinet": "UC3103", + "pos": [ + 226360.6, + 458836.2 + ] + }, + { + "id": "BG3150", + "constant": "cInBG3150", + "hwAddress": "%E315.0", + "comment": "Stausensor Str.1 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 208400.0, + 457808.0 + ] + }, + { + "id": "BG3151", + "constant": "cInBG3151", + "hwAddress": "%E315.1", + "comment": "Stausensor Str.2 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 209200.0, + 457807.9 + ] + }, + { + "id": "BG3152", + "constant": "cInBG3152", + "hwAddress": "%E315.2", + "comment": "Stausensor Str.3 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 210000.0, + 457807.9 + ] + }, + { + "id": "BG3153", + "constant": "cInBG3153", + "hwAddress": "%E315.3", + "comment": "Stausensor Str.4 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 211146.1, + 457807.8 + ] + }, + { + "id": "BG3154", + "constant": "cInBG3154", + "hwAddress": "%E315.4", + "comment": "Stausensor Str.5 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 211946.1, + 457807.8 + ] + }, + { + "id": "BG3155", + "constant": "cInBG3155", + "hwAddress": "%E315.5", + "comment": "Stausensor Str.6 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 212746.1, + 457807.9 + ] + }, + { + "id": "BG3156", + "constant": "cInBG3156", + "hwAddress": "%E315.6", + "comment": "Stausensor Str.7 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 213545.3, + 457807.8 + ] + }, + { + "id": "BG3157", + "constant": "cInBG3157", + "hwAddress": "%E315.7", + "comment": "Stausensor Str.8 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 214346.1, + 457807.8 + ] + }, + { + "id": "BG3160", + "constant": "cInBG3160", + "hwAddress": "%E316.0", + "comment": "Stausensor Str.9 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 215146.1, + 457808.6 + ] + }, + { + "id": "BG3161", + "constant": "cInBG3161", + "hwAddress": "%E316.1", + "comment": "Stausensor Str.10 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 217150.0, + 457807.7 + ] + }, + { + "id": "BG3162", + "constant": "cInBG3162", + "hwAddress": "%E316.2", + "comment": "Stausensor Str.11 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 217950.0, + 457807.7 + ] + }, + { + "id": "BG3163", + "constant": "cInBG3163", + "hwAddress": "%E316.3", + "comment": "Stausensor Str.12 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 218750.0, + 457807.6 + ] + }, + { + "id": "BG3164", + "constant": "cInBG3164", + "hwAddress": "%E316.4", + "comment": "Stausensor Str.13 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 219549.1, + 457807.6 + ] + }, + { + "id": "BG3165", + "constant": "cInBG3165", + "hwAddress": "%E316.5", + "comment": "Stausensor Str.14 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 220350.0, + 457807.6 + ] + }, + { + "id": "BG3166", + "constant": "cInBG3166", + "hwAddress": "%E316.6", + "comment": "Stausensor Str.15 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 221150.0, + 457807.7 + ] + }, + { + "id": "BG3167", + "constant": "cInBG3167", + "hwAddress": "%E316.7", + "comment": "Stausensor Str.16 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 221950.0, + 457807.6 + ] + }, + { + "id": "BG3170", + "constant": "cInBG3170", + "hwAddress": "%E317.0", + "comment": "Stausensor Str.17 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 223150.0, + 457807.6 + ] + }, + { + "id": "BG3171", + "constant": "cInBG3171", + "hwAddress": "%E317.1", + "comment": "Stausensor Str.18 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 223950.0, + 457807.7 + ] + }, + { + "id": "BG3172", + "constant": "cInBG3172", + "hwAddress": "%E317.2", + "comment": "Stausensor Str.19 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 224748.4, + 457807.6 + ] + }, + { + "id": "BG3173", + "constant": "cInBG3173", + "hwAddress": "%E317.3", + "comment": "Stausensor Str.20 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 225550.0, + 457807.7 + ] + }, + { + "id": "BG3174", + "constant": "cInBG3174", + "hwAddress": "%E317.4", + "comment": "Stausensor Str.21 (Block 2.1.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3103", + "pos": [ + 226350.0, + 457807.7 + ] + }, + { + "id": "BG3180", + "constant": "cInBG3180", + "hwAddress": "%E318.0", + "comment": "in Separator 2 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 227619.3, + 457857.7 + ] + }, + { + "id": "BG3181", + "constant": "cInBG3181", + "hwAddress": "%E318.1", + "comment": "Pin Abfrage (KR-M2102 ) Block 2.1.4", + "role": "sensorPinQuery", + "unit": "M2102", + "cabinet": "UC3104", + "pos": [ + 227916.3, + 458837.5 + ] + }, + { + "id": "BG3182", + "constant": "cInBG3182", + "hwAddress": "%E318.2", + "comment": "Prüfung MT Pos.1 (KR-K2102 Einfahrt Block 2.1.4)", + "role": "sensorPinQuery", + "unit": "K2102", + "cabinet": "UC3104", + "pos": [ + 228219.5, + 459133.9 + ] + }, + { + "id": "BG3183", + "constant": "cInBG3183", + "hwAddress": "%E318.3", + "comment": "Stausensor (KR-M2102 Block 2.1.4)", + "role": "sensorJam", + "unit": "M2102", + "cabinet": "UC3104", + "pos": [ + 227156.9, + 458839.5 + ] + }, + { + "id": "BG3184", + "constant": "cInBG3184", + "hwAddress": "%E318.4", + "comment": "in Separator 1 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 227614.4, + 457275.6 + ] + }, + { + "id": "BG3185", + "constant": "cInBG3185", + "hwAddress": "%E318.5", + "comment": "Stausensor Str.1 (KR-K2102 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K2102", + "cabinet": "UC3104", + "pos": [ + 227612.7, + 456964.4 + ] + }, + { + "id": "BG3186", + "constant": "cInBG3186", + "hwAddress": "%E318.6", + "comment": "Sensor Förderer voll (ILS-CV 2102)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 227611.1, + 456340.9 + ] + }, + { + "id": "BG3187", + "constant": "cInBG3187", + "hwAddress": "%E318.7", + "comment": "Prüfung MT Pos.2 (KR-K2102 Einfahrt Block 2.1.4)", + "role": "sensorPinQuery", + "unit": "K2102", + "cabinet": "UC3104", + "pos": [ + 231576.6, + 459136.8 + ] + }, + { + "id": "BG3190", + "constant": "cInBG3190", + "hwAddress": "%E319.0", + "comment": "Prüfung MT Pos.3 (KR-K2102 Einfahrt Block 2.1.4)", + "role": "sensorPinQuery", + "unit": "K2102", + "cabinet": "UC3104", + "pos": [ + 234839.3, + 459122.4 + ] + }, + { + "id": "BG3191", + "constant": "cInBG3191", + "hwAddress": "%E319.1", + "comment": "Prüfung MT Pos.4 (KR-K2102 Einfahrt Block 2.1.4)", + "role": "sensorPinQuery", + "unit": "K2102", + "cabinet": "UC3104", + "pos": [ + 238060.0, + 459126.0 + ] + }, + { + "id": "BG3192", + "constant": "cInBG3192", + "hwAddress": "%E319.2", + "comment": "in Separator 3 (KR-M2102 Block 2.1.4)", + "role": "sensorInSep", + "unit": "M2102", + "cabinet": "UC3104", + "pos": [ + 241338.5, + 457904.2 + ] + }, + { + "id": "BG3193", + "constant": "cInBG3193", + "hwAddress": "%E319.3", + "comment": "Stausensor (KR-M2102 Block 2.1.4)", + "role": "sensorJam", + "unit": "M2102", + "cabinet": "UC3104", + "pos": [ + 239381.8, + 458837.5 + ] + }, + { + "id": "BG3194", + "constant": "cInBG3194", + "hwAddress": "%E319.4", + "comment": "Stausensor (KR-M2102 Block 2.1.4)", + "role": "sensorJam", + "unit": "M2102", + "cabinet": "UC3104", + "pos": [ + 241352.5, + 459590.7 + ] + }, + { + "id": "BG3210", + "constant": "cInBG3210", + "hwAddress": "%E321.0", + "comment": "Stausensor Str.1 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 229150.0, + 457808.0 + ] + }, + { + "id": "BG3211", + "constant": "cInBG3211", + "hwAddress": "%E321.1", + "comment": "Stausensor Str.2 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 229950.0, + 457807.9 + ] + }, + { + "id": "BG3212", + "constant": "cInBG3212", + "hwAddress": "%E321.2", + "comment": "Stausensor Str.3 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 230750.0, + 457807.9 + ] + }, + { + "id": "BG3213", + "constant": "cInBG3213", + "hwAddress": "%E321.3", + "comment": "Stausensor Str.4 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 231550.0, + 457807.8 + ] + }, + { + "id": "BG3214", + "constant": "cInBG3214", + "hwAddress": "%E321.4", + "comment": "Stausensor Str.5 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 232350.0, + 457807.8 + ] + }, + { + "id": "BG3215", + "constant": "cInBG3215", + "hwAddress": "%E321.5", + "comment": "Stausensor Str.6 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 233150.0, + 457807.9 + ] + }, + { + "id": "BG3216", + "constant": "cInBG3216", + "hwAddress": "%E321.6", + "comment": "Stausensor Str.7 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 233949.1, + 457807.8 + ] + }, + { + "id": "BG3217", + "constant": "cInBG3217", + "hwAddress": "%E321.7", + "comment": "Stausensor Str.8 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 235150.0, + 457808.6 + ] + }, + { + "id": "BG3220", + "constant": "cInBG3220", + "hwAddress": "%E322.0", + "comment": "Stausensor Str.9 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 235950.0, + 457808.6 + ] + }, + { + "id": "BG3221", + "constant": "cInBG3221", + "hwAddress": "%E322.1", + "comment": "Stausensor Str.10 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 236750.0, + 457807.7 + ] + }, + { + "id": "BG3222", + "constant": "cInBG3222", + "hwAddress": "%E322.2", + "comment": "Stausensor Str.11 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 237550.0, + 457807.7 + ] + }, + { + "id": "BG3223", + "constant": "cInBG3223", + "hwAddress": "%E322.3", + "comment": "Stausensor Str.12 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 238350.0, + 457807.6 + ] + }, + { + "id": "BG3224", + "constant": "cInBG3224", + "hwAddress": "%E322.4", + "comment": "Stausensor Str.13 (Block 2.1.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3104", + "pos": [ + 239149.1, + 457807.6 + ] + }, + { + "id": "BG3240", + "constant": "cInBG3240", + "hwAddress": "%E324.0", + "comment": "in Separator 1 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 186664.6, + 441059.5 + ] + }, + { + "id": "BG3241", + "constant": "cInBG3241", + "hwAddress": "%E324.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2105)", + "role": "sensorJam", + "unit": "M2105", + "cabinet": "UC0301", + "pos": [ + 187189.0, + 442337.7 + ] + }, + { + "id": "BG3242", + "constant": "cInBG3242", + "hwAddress": "%E324.2", + "comment": "Stausensor 1 (KR-M2103 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M2103", + "cabinet": "UC0301", + "pos": [ + 186431.0, + 442042.8 + ] + }, + { + "id": "BG3243", + "constant": "cInBG3243", + "hwAddress": "%E324.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2105)", + "role": "sensorFinger", + "unit": "M2105", + "cabinet": "UC0301", + "pos": [ + 187191.9, + 443224.4 + ] + }, + { + "id": "BG3244", + "constant": "cInBG3244", + "hwAddress": "%E324.4", + "comment": "in Separator (ILS-CV M2105)", + "role": "sensorInSep", + "unit": "M2105", + "cabinet": "UC0301", + "pos": [ + 187189.2, + 442645.6 + ] + }, + { + "id": "BG3245", + "constant": "cInBG3245", + "hwAddress": "%E324.5", + "comment": "in Separator (KR-M2103)", + "role": "sensorInSep", + "unit": "M2103", + "cabinet": "UC0301", + "pos": [ + 170876.7, + 440356.5 + ] + }, + { + "id": "BG3247", + "constant": "cInBG3247", + "hwAddress": "%E324.7", + "comment": "MT in Position (ILS-CV M2105)", + "role": "sensorCarrInPos", + "unit": "M2105", + "cabinet": "UC0301", + "pos": [ + 187189.2, + 443491.0 + ] + }, + { + "id": "BG3270", + "constant": "cInBG3270", + "hwAddress": "%E327.0", + "comment": "in Separator 1 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 185950.0, + 442667.6 + ] + }, + { + "id": "BG3271", + "constant": "cInBG3271", + "hwAddress": "%E327.1", + "comment": "in Separator 2 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 185150.0, + 442667.6 + ] + }, + { + "id": "BG3272", + "constant": "cInBG3272", + "hwAddress": "%E327.2", + "comment": "in Separator 3 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 184350.0, + 442667.6 + ] + }, + { + "id": "BG3273", + "constant": "cInBG3273", + "hwAddress": "%E327.3", + "comment": "in Separator 4 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 183550.0, + 442667.6 + ] + }, + { + "id": "BG3274", + "constant": "cInBG3274", + "hwAddress": "%E327.4", + "comment": "in Separator 5 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 182750.0, + 442667.6 + ] + }, + { + "id": "BG3275", + "constant": "cInBG3275", + "hwAddress": "%E327.5", + "comment": "in Separator 6 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 181950.0, + 442667.6 + ] + }, + { + "id": "BG3276", + "constant": "cInBG3276", + "hwAddress": "%E327.6", + "comment": "in Separator 7 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 181150.0, + 442667.6 + ] + }, + { + "id": "BG3277", + "constant": "cInBG3277", + "hwAddress": "%E327.7", + "comment": "in Separator 8 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 179149.9, + 442667.6 + ] + }, + { + "id": "BG3280", + "constant": "cInBG3280", + "hwAddress": "%E328.0", + "comment": "in Separator 9 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 178349.9, + 442667.6 + ] + }, + { + "id": "BG3281", + "constant": "cInBG3281", + "hwAddress": "%E328.1", + "comment": "in Separator 10 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 177549.9, + 442667.6 + ] + }, + { + "id": "BG3282", + "constant": "cInBG3282", + "hwAddress": "%E328.2", + "comment": "in Separator 11 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 176749.9, + 442667.6 + ] + }, + { + "id": "BG3283", + "constant": "cInBG3283", + "hwAddress": "%E328.3", + "comment": "in Separator 12 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 175949.9, + 442667.6 + ] + }, + { + "id": "BG3284", + "constant": "cInBG3284", + "hwAddress": "%E328.4", + "comment": "in Separator 13 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 175149.9, + 442667.6 + ] + }, + { + "id": "BG3285", + "constant": "cInBG3285", + "hwAddress": "%E328.5", + "comment": "in Separator 14 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 174000.0, + 442667.5 + ] + }, + { + "id": "BG3286", + "constant": "cInBG3286", + "hwAddress": "%E328.6", + "comment": "in Separator 15 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 173200.0, + 442667.5 + ] + }, + { + "id": "BG3287", + "constant": "cInBG3287", + "hwAddress": "%E328.7", + "comment": "in Separator 16 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 172400.0, + 442667.5 + ] + }, + { + "id": "BG3290", + "constant": "cInBG3290", + "hwAddress": "%E329.0", + "comment": "in Separator 17 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 171600.0, + 442667.5 + ] + }, + { + "id": "BG3291", + "constant": "cInBG3291", + "hwAddress": "%E329.1", + "comment": "in Separator 18 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 170800.0, + 442667.5 + ] + }, + { + "id": "BG3292", + "constant": "cInBG3292", + "hwAddress": "%E329.2", + "comment": "In Separator 19 (Block 2.1.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0301", + "pos": [ + 170000.0, + 442667.5 + ] + }, + { + "id": "BG3300", + "constant": "cInBG3300", + "hwAddress": "%E330.0", + "comment": "in Separator 1 (KR-M2103 Block 2.1.2)", + "role": "sensorInSep", + "unit": "M2103", + "cabinet": "UC0302", + "pos": [ + 203430.1, + 441083.0 + ] + }, + { + "id": "BG3301", + "constant": "cInBG3301", + "hwAddress": "%E330.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2106)", + "role": "sensorJam", + "unit": "M2106", + "cabinet": "UC0302", + "pos": [ + 204428.4, + 442357.8 + ] + }, + { + "id": "BG3302", + "constant": "cInBG3302", + "hwAddress": "%E330.2", + "comment": "Stausensor 1 (KR-M2103 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M2103", + "cabinet": "UC0302", + "pos": [ + 203631.0, + 442042.7 + ] + }, + { + "id": "BG3303", + "constant": "cInBG3303", + "hwAddress": "%E330.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2106)", + "role": "sensorFinger", + "unit": "M2106", + "cabinet": "UC0302", + "pos": [ + 204431.1, + 443231.9 + ] + }, + { + "id": "BG3304", + "constant": "cInBG3304", + "hwAddress": "%E330.4", + "comment": "in Separator (ILS-CV M2106)", + "role": "sensorInSep", + "unit": "M2106", + "cabinet": "UC0302", + "pos": [ + 204428.4, + 442653.9 + ] + }, + { + "id": "BG3305", + "constant": "cInBG3305", + "hwAddress": "%E330.5", + "comment": "Stausensor 2 (KR-M2103)", + "role": "sensorJam", + "unit": "M2103", + "cabinet": "UC0302", + "pos": [ + 203508.4, + 440601.8 + ] + }, + { + "id": "BG3306", + "constant": "cInBG3306", + "hwAddress": "%E330.6", + "comment": "Rad dreht (KR-M2103)", + "role": "sensorWheel", + "unit": "M2103", + "cabinet": "UC0302", + "pos": [ + 204250.9, + 440589.9 + ] + }, + { + "id": "BG3307", + "constant": "cInBG3307", + "hwAddress": "%E330.7", + "comment": "MT in Position (ILS-CV M2106)", + "role": "sensorCarrInPos", + "unit": "M2106", + "cabinet": "UC0302", + "pos": [ + 204428.4, + 443498.4 + ] + }, + { + "id": "BG3330", + "constant": "cInBG3330", + "hwAddress": "%E333.0", + "comment": "in Separator 1 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 203150.0, + 442667.6 + ] + }, + { + "id": "BG3331", + "constant": "cInBG3331", + "hwAddress": "%E333.1", + "comment": "in Separator 2 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 202350.0, + 442667.6 + ] + }, + { + "id": "BG3332", + "constant": "cInBG3332", + "hwAddress": "%E333.2", + "comment": "in Separator 3 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 201550.0, + 442667.6 + ] + }, + { + "id": "BG3333", + "constant": "cInBG3333", + "hwAddress": "%E333.3", + "comment": "in Separator 4 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 200750.0, + 442667.6 + ] + }, + { + "id": "BG3334", + "constant": "cInBG3334", + "hwAddress": "%E333.4", + "comment": "in Separator 5 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 199950.0, + 442667.6 + ] + }, + { + "id": "BG3335", + "constant": "cInBG3335", + "hwAddress": "%E333.5", + "comment": "in Separator 6 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 199150.0, + 442667.6 + ] + }, + { + "id": "BG3336", + "constant": "cInBG3336", + "hwAddress": "%E333.6", + "comment": "in Separator 7 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 197950.0, + 442667.6 + ] + }, + { + "id": "BG3337", + "constant": "cInBG3337", + "hwAddress": "%E333.7", + "comment": "in Separator 8 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 197100.0, + 442667.6 + ] + }, + { + "id": "BG3340", + "constant": "cInBG3340", + "hwAddress": "%E334.0", + "comment": "in Separator 9 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 196300.0, + 442667.6 + ] + }, + { + "id": "BG3341", + "constant": "cInBG3341", + "hwAddress": "%E334.1", + "comment": "in Separator 10 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 195500.0, + 442667.6 + ] + }, + { + "id": "BG3342", + "constant": "cInBG3342", + "hwAddress": "%E334.2", + "comment": "in Separator 11 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 194700.0, + 442667.6 + ] + }, + { + "id": "BG3343", + "constant": "cInBG3343", + "hwAddress": "%E334.3", + "comment": "in Separator 12 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 193900.0, + 442667.6 + ] + }, + { + "id": "BG3344", + "constant": "cInBG3344", + "hwAddress": "%E334.4", + "comment": "in Separator 13 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 193100.0, + 442667.6 + ] + }, + { + "id": "BG3345", + "constant": "cInBG3345", + "hwAddress": "%E334.5", + "comment": "in Separator 14 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 191300.0, + 442667.6 + ] + }, + { + "id": "BG3346", + "constant": "cInBG3346", + "hwAddress": "%E334.6", + "comment": "in Separator 15 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 190500.0, + 442667.6 + ] + }, + { + "id": "BG3347", + "constant": "cInBG3347", + "hwAddress": "%E334.7", + "comment": "in Separator 16 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 189700.0, + 442667.6 + ] + }, + { + "id": "BG3350", + "constant": "cInBG3350", + "hwAddress": "%E335.0", + "comment": "in Separator 17 (Block 2.1.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0202", + "pos": [ + 188900.0, + 442667.6 + ] + }, + { + "id": "BG3360", + "constant": "cInBG3360", + "hwAddress": "%E336.0", + "comment": "in Separator 1 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0303", + "pos": [ + 207829.4, + 441184.8 + ] + }, + { + "id": "BG3361", + "constant": "cInBG3361", + "hwAddress": "%E336.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2107)", + "role": "sensorJam", + "unit": "M2107", + "cabinet": "UC0303", + "pos": [ + 206540.2, + 442318.1 + ] + }, + { + "id": "BG3362", + "constant": "cInBG3362", + "hwAddress": "%E336.2", + "comment": "Stausensor 1 (KR-M2104 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M2104", + "cabinet": "UC0303", + "pos": [ + 207312.3, + 442058.0 + ] + }, + { + "id": "BG3363", + "constant": "cInBG3363", + "hwAddress": "%E336.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2107)", + "role": "sensorFinger", + "unit": "M2107", + "cabinet": "UC0303", + "pos": [ + 206542.9, + 443176.2 + ] + }, + { + "id": "BG3364", + "constant": "cInBG3364", + "hwAddress": "%E336.4", + "comment": "in Separator (ILS-CV M2107)", + "role": "sensorInSep", + "unit": "M2107", + "cabinet": "UC0303", + "pos": [ + 206540.2, + 442613.2 + ] + }, + { + "id": "BG3365", + "constant": "cInBG3365", + "hwAddress": "%E336.5", + "comment": "Stausensor (ILS-KR-M2104)", + "role": "sensorJam", + "unit": "M2104", + "cabinet": "UC0303", + "pos": [ + 205915.4, + 440597.0 + ] + }, + { + "id": "BG3367", + "constant": "cInBG3367", + "hwAddress": "%E336.7", + "comment": "MT in Position (ILS-CV M2107)", + "role": "sensorCarrInPos", + "unit": "M2107", + "cabinet": "UC0303", + "pos": [ + 206540.2, + 443442.8 + ] + }, + { + "id": "BG3390", + "constant": "cInBG3390", + "hwAddress": "%E339.0", + "comment": "in Separator 1 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 208400.0, + 442667.6 + ] + }, + { + "id": "BG3391", + "constant": "cInBG3391", + "hwAddress": "%E339.1", + "comment": "in Separator 2 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 209200.0, + 442667.6 + ] + }, + { + "id": "BG3392", + "constant": "cInBG3392", + "hwAddress": "%E339.2", + "comment": "in Separator 3 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 210000.0, + 442667.6 + ] + }, + { + "id": "BG3393", + "constant": "cInBG3393", + "hwAddress": "%E339.3", + "comment": "in Separator 4 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 211150.0, + 442667.6 + ] + }, + { + "id": "BG3394", + "constant": "cInBG3394", + "hwAddress": "%E339.4", + "comment": "in Separator 5 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 211950.0, + 442667.6 + ] + }, + { + "id": "BG3395", + "constant": "cInBG3395", + "hwAddress": "%E339.5", + "comment": "in Separator 6 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 212750.0, + 442667.6 + ] + }, + { + "id": "BG3396", + "constant": "cInBG3396", + "hwAddress": "%E339.6", + "comment": "in Separator 7 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 213550.0, + 442667.6 + ] + }, + { + "id": "BG3397", + "constant": "cInBG3397", + "hwAddress": "%E339.7", + "comment": "in Separator 8 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 214350.0, + 442667.6 + ] + }, + { + "id": "BG3400", + "constant": "cInBG3400", + "hwAddress": "%E340.0", + "comment": "in Separator 9 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 215150.0, + 442667.6 + ] + }, + { + "id": "BG3401", + "constant": "cInBG3401", + "hwAddress": "%E340.1", + "comment": "in Separator 10 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 217150.0, + 442667.6 + ] + }, + { + "id": "BG3402", + "constant": "cInBG3402", + "hwAddress": "%E340.2", + "comment": "in Separator 11 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 217950.0, + 442667.6 + ] + }, + { + "id": "BG3403", + "constant": "cInBG3403", + "hwAddress": "%E340.3", + "comment": "in Separator 12 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 218750.0, + 442667.6 + ] + }, + { + "id": "BG3404", + "constant": "cInBG3404", + "hwAddress": "%E340.4", + "comment": "in Separator 13 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 219550.0, + 442667.6 + ] + }, + { + "id": "BG3405", + "constant": "cInBG3405", + "hwAddress": "%E340.5", + "comment": "in Separator 14 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 220350.0, + 442667.6 + ] + }, + { + "id": "BG3406", + "constant": "cInBG3406", + "hwAddress": "%E340.6", + "comment": "in Separator 15 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 221150.0, + 442667.6 + ] + }, + { + "id": "BG3407", + "constant": "cInBG3407", + "hwAddress": "%E340.7", + "comment": "in Separator 16 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 221950.0, + 442667.6 + ] + }, + { + "id": "BG3410", + "constant": "cInBG3410", + "hwAddress": "%E341.0", + "comment": "in Separator 17 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 223150.0, + 442667.6 + ] + }, + { + "id": "BG3411", + "constant": "cInBG3411", + "hwAddress": "%E341.1", + "comment": "in Separator 18 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 223950.0, + 442667.6 + ] + }, + { + "id": "BG3412", + "constant": "cInBG3412", + "hwAddress": "%E341.2", + "comment": "in Separator 19 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 224750.0, + 442667.6 + ] + }, + { + "id": "BG3413", + "constant": "cInBG3413", + "hwAddress": "%E341.3", + "comment": "in Separator 20 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 225550.0, + 442667.6 + ] + }, + { + "id": "BG3414", + "constant": "cInBG3414", + "hwAddress": "%E341.4", + "comment": "in Separator 21 (Block 2.1.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0203", + "pos": [ + 226350.0, + 442667.6 + ] + }, + { + "id": "BG3420", + "constant": "cInBG3420", + "hwAddress": "%E342.0", + "comment": "in Separator 1 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 228310.7, + 441208.2 + ] + }, + { + "id": "BG3421", + "constant": "cInBG3421", + "hwAddress": "%E342.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2108)", + "role": "sensorJam", + "unit": "M2108", + "cabinet": "UC0304", + "pos": [ + 227501.9, + 442318.2 + ] + }, + { + "id": "BG3422", + "constant": "cInBG3422", + "hwAddress": "%E342.2", + "comment": "Stausensor 1 (KR-M2104 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M2104", + "cabinet": "UC0304", + "pos": [ + 228273.8, + 442042.8 + ] + }, + { + "id": "BG3423", + "constant": "cInBG3423", + "hwAddress": "%E342.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2108)", + "role": "sensorFinger", + "unit": "M2108", + "cabinet": "UC0304", + "pos": [ + 227504.6, + 443172.0 + ] + }, + { + "id": "BG3424", + "constant": "cInBG3424", + "hwAddress": "%E342.4", + "comment": "in Separator (ILS-CV M2108)", + "role": "sensorInSep", + "unit": "M2108", + "cabinet": "UC0304", + "pos": [ + 227501.9, + 442604.1 + ] + }, + { + "id": "BG3425", + "constant": "cInBG3425", + "hwAddress": "%E342.5", + "comment": "in Separator 3 (ILS-CV M2104 Block 2.1.4)", + "role": "sensorInSep", + "unit": "M2104", + "cabinet": "UC0304", + "pos": [ + 237420.4, + 441131.7 + ] + }, + { + "id": "BG3426", + "constant": "cInBG3426", + "hwAddress": "%E342.6", + "comment": "Stausensor 1 (M2104)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 238544.6, + 441131.7 + ] + }, + { + "id": "BG3427", + "constant": "cInBG3427", + "hwAddress": "%E342.7", + "comment": "MT in Position (ILS-CV M2108)", + "role": "sensorCarrInPos", + "unit": "M2108", + "cabinet": "UC0304", + "pos": [ + 227501.9, + 443440.8 + ] + }, + { + "id": "BG3431", + "constant": "cInBG3431", + "hwAddress": "%E343.1", + "comment": "in Separator 4 (ILS-CV M2104 Block 2.1.4)", + "role": "sensorInSep", + "unit": "M2104", + "cabinet": "UC0304", + "pos": [ + 240232.5, + 440258.2 + ] + }, + { + "id": "BG3432", + "constant": "cInBG3432", + "hwAddress": "%E343.2", + "comment": "in Separator 1 (ILS-CV M2109 Block 2.1.4)", + "role": "sensorInSep", + "unit": "M2109", + "cabinet": "UC0304", + "pos": [ + 237421.5, + 440384.1 + ] + }, + { + "id": "BG3433", + "constant": "cInBG3433", + "hwAddress": "%E343.3", + "comment": "Sensor Förderer voll (ILS-CV 2109)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 236565.8, + 440396.1 + ] + }, + { + "id": "BG3434", + "constant": "cInBG3434", + "hwAddress": "%E343.4", + "comment": "Stausensor 1 (M2109)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 238268.1, + 439519.3 + ] + }, + { + "id": "BG3435", + "constant": "cInBG3435", + "hwAddress": "%E343.5", + "comment": "Stausensor 2 (KR-M2109)", + "role": "sensorJam", + "unit": "M2109", + "cabinet": "UC0304", + "pos": [ + 239350.7, + 440258.2 + ] + }, + { + "id": "BG3436", + "constant": "cInBG3436", + "hwAddress": "%E343.6", + "comment": "Rad dreht (KR-M2104)", + "role": "sensorWheel", + "unit": "M2104", + "cabinet": "UC0304", + "pos": [ + 241406.9, + 440528.2 + ] + }, + { + "id": "BG3437", + "constant": "cInBG3437", + "hwAddress": "%E343.7", + "comment": "Stausensor Einfahrt Varioförderer (M1401)", + "role": "sensorJam", + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG3440", + "constant": "cInBG3440", + "hwAddress": "%E344.0", + "comment": "in Separator (ILS-CV M2109)", + "role": "sensorInSep", + "unit": "M2109", + "cabinet": "UC0304", + "pos": [ + 229500.6, + 290448.6 + ] + }, + { + "id": "BG3441", + "constant": "cInBG3441", + "hwAddress": "%E344.1", + "comment": "MT in Position (ILS-CV M2109)", + "role": "sensorCarrInPos", + "unit": "M2109", + "cabinet": "UC0304", + "pos": [ + 230985.6, + 290448.6 + ] + }, + { + "id": "BG3442", + "constant": "cInBG3442", + "hwAddress": "%E344.2", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2109)", + "role": "sensorFinger", + "unit": "M2109", + "cabinet": "UC0304", + "pos": [ + 230256.8, + 290458.4 + ] + }, + { + "id": "BG3450", + "constant": "cInBG3450", + "hwAddress": "%E345.0", + "comment": "in Separator 1 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 229150.0, + 442667.6 + ] + }, + { + "id": "BG3451", + "constant": "cInBG3451", + "hwAddress": "%E345.1", + "comment": "in Separator 2 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 229950.0, + 442667.6 + ] + }, + { + "id": "BG3452", + "constant": "cInBG3452", + "hwAddress": "%E345.2", + "comment": "in Separator 3 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 230750.0, + 442667.6 + ] + }, + { + "id": "BG3453", + "constant": "cInBG3453", + "hwAddress": "%E345.3", + "comment": "in Separator 4 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 231550.0, + 442667.6 + ] + }, + { + "id": "BG3454", + "constant": "cInBG3454", + "hwAddress": "%E345.4", + "comment": "in Separator 5 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 232350.0, + 442667.6 + ] + }, + { + "id": "BG3455", + "constant": "cInBG3455", + "hwAddress": "%E345.5", + "comment": "in Separator 6 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 233150.0, + 442667.6 + ] + }, + { + "id": "BG3456", + "constant": "cInBG3456", + "hwAddress": "%E345.6", + "comment": "in Separator 7 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 233950.0, + 442667.6 + ] + }, + { + "id": "BG3457", + "constant": "cInBG3457", + "hwAddress": "%E345.7", + "comment": "in Separator 8 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 235150.0, + 442667.6 + ] + }, + { + "id": "BG3460", + "constant": "cInBG3460", + "hwAddress": "%E346.0", + "comment": "in Separator 9 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 235950.0, + 442667.6 + ] + }, + { + "id": "BG3461", + "constant": "cInBG3461", + "hwAddress": "%E346.1", + "comment": "in Separator 10 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 236750.0, + 442667.6 + ] + }, + { + "id": "BG3462", + "constant": "cInBG3462", + "hwAddress": "%E346.2", + "comment": "in Separator 11 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 237550.0, + 442667.6 + ] + }, + { + "id": "BG3463", + "constant": "cInBG3463", + "hwAddress": "%E346.3", + "comment": "in Separator 12 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 238350.0, + 442667.6 + ] + }, + { + "id": "BG3464", + "constant": "cInBG3464", + "hwAddress": "%E346.4", + "comment": "in Separator 13 (Block 2.1.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0304", + "pos": [ + 239150.0, + 442667.6 + ] + }, + { + "id": "BG3480", + "constant": "cInBG3480", + "hwAddress": "%E348.0", + "comment": "in Separator 2 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 187132.0, + 436871.7 + ] + }, + { + "id": "BG3481", + "constant": "cInBG3481", + "hwAddress": "%E348.1", + "comment": "Pin Abfrage (KR-M2201 ) Block 2.2.1", + "role": "sensorPinQuery", + "unit": "M2201", + "cabinet": "UC0305", + "pos": [ + 186977.5, + 437835.0 + ] + }, + { + "id": "BG3482", + "constant": "cInBG3482", + "hwAddress": "%E348.2", + "comment": "Prüfung MT Pos.1 (KR-K2201 Einfahrt Block 2.2.1)", + "role": "sensorPinQuery", + "unit": "K2201", + "cabinet": "UC0305", + "pos": [ + 186578.7, + 438134.2 + ] + }, + { + "id": "BG3483", + "constant": "cInBG3483", + "hwAddress": "%E348.3", + "comment": "Stausensor (KR-M2201) Block 2.2.1", + "role": "sensorJam", + "unit": "M2201", + "cabinet": "UC0305", + "pos": [ + 187781.9, + 437835.0 + ] + }, + { + "id": "BG3484", + "constant": "cInBG3484", + "hwAddress": "%E348.4", + "comment": "in Separator 1 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 187127.8, + 436279.5 + ] + }, + { + "id": "BG3485", + "constant": "cInBG3485", + "hwAddress": "%E348.5", + "comment": "Stausensor Str.1 (KR-K2205 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K2205", + "cabinet": "UC0305", + "pos": [ + 187126.0, + 435968.4 + ] + }, + { + "id": "BG3486", + "constant": "cInBG3486", + "hwAddress": "%E348.6", + "comment": "Sensor Förderer voll (ILS-CV M2205)", + "role": "sensorConvFull", + "unit": "M2205", + "cabinet": "UC0205", + "pos": [ + 187126.0, + 435348.5 + ] + }, + { + "id": "BG3487", + "constant": "cInBG3487", + "hwAddress": "%E348.7", + "comment": "Prüfung MT Pos.2 (KR-K2201 Einfahrt Block 2.2.1)", + "role": "sensorPinQuery", + "unit": "K2201", + "cabinet": "UC0305", + "pos": [ + 183192.3, + 438127.8 + ] + }, + { + "id": "BG3490", + "constant": "cInBG3490", + "hwAddress": "%E349.0", + "comment": "Prüfung MT Pos.3 (KR-K2201 Einfahrt Block 2.2.1)", + "role": "sensorPinQuery", + "unit": "K2201", + "cabinet": "UC0305", + "pos": [ + 178779.0, + 438122.4 + ] + }, + { + "id": "BG3491", + "constant": "cInBG3491", + "hwAddress": "%E349.1", + "comment": "Prüfung MT Pos.4 (KR-K2201 Einfahrt Block 2.2.1)", + "role": "sensorPinQuery", + "unit": "K2201", + "cabinet": "UC0305", + "pos": [ + 175605.8, + 438122.4 + ] + }, + { + "id": "BG3510", + "constant": "cInBG3510", + "hwAddress": "%E351.0", + "comment": "Stausensor Str.1 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 185950.0, + 436695.7 + ] + }, + { + "id": "BG3511", + "constant": "cInBG3511", + "hwAddress": "%E351.1", + "comment": "Stausensor Str.2 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 185150.0, + 436822.3 + ] + }, + { + "id": "BG3512", + "constant": "cInBG3512", + "hwAddress": "%E351.2", + "comment": "Stausensor Str.3 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 184349.9, + 436822.3 + ] + }, + { + "id": "BG3513", + "constant": "cInBG3513", + "hwAddress": "%E351.3", + "comment": "Stausensor Str.4 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 183550.0, + 436822.0 + ] + }, + { + "id": "BG3514", + "constant": "cInBG3514", + "hwAddress": "%E351.4", + "comment": "Stausensor Str.5 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 182749.9, + 436822.3 + ] + }, + { + "id": "BG3515", + "constant": "cInBG3515", + "hwAddress": "%E351.5", + "comment": "Stausensor Str.6 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 181949.9, + 436822.3 + ] + }, + { + "id": "BG3516", + "constant": "cInBG3516", + "hwAddress": "%E351.6", + "comment": "Stausensor Str.7 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 181150.0, + 436822.0 + ] + }, + { + "id": "BG3517", + "constant": "cInBG3517", + "hwAddress": "%E351.7", + "comment": "Stausensor Str.8 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 179149.9, + 436822.2 + ] + }, + { + "id": "BG3520", + "constant": "cInBG3520", + "hwAddress": "%E352.0", + "comment": "Stausensor Str.9 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 178349.9, + 436822.2 + ] + }, + { + "id": "BG3521", + "constant": "cInBG3521", + "hwAddress": "%E352.1", + "comment": "Stausensor Str.10 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 177550.0, + 436821.9 + ] + }, + { + "id": "BG3522", + "constant": "cInBG3522", + "hwAddress": "%E352.2", + "comment": "Stausensor Str.11 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 176749.9, + 436822.2 + ] + }, + { + "id": "BG3523", + "constant": "cInBG3523", + "hwAddress": "%E352.3", + "comment": "Stausensor Str.12 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 175949.9, + 436822.3 + ] + }, + { + "id": "BG3524", + "constant": "cInBG3524", + "hwAddress": "%E352.4", + "comment": "Stausensor Str.13 (Block 2.2.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0305", + "pos": [ + 175150.0, + 436822.0 + ] + }, + { + "id": "BG3540", + "constant": "cInBG3540", + "hwAddress": "%E354.0", + "comment": "in Separator 2 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 204368.7, + 436871.7 + ] + }, + { + "id": "BG3541", + "constant": "cInBG3541", + "hwAddress": "%E354.1", + "comment": "Pin Abfrage (KR-M2201 ) Block 2.2.2", + "role": "sensorPinQuery", + "unit": "M2201", + "cabinet": "UC0306", + "pos": [ + 204081.7, + 437835.0 + ] + }, + { + "id": "BG3542", + "constant": "cInBG3542", + "hwAddress": "%E354.2", + "comment": "Prüfung MT Pos.1 (KR-K2201 Einfahrt Block 2.2.2)", + "role": "sensorPinQuery", + "unit": "K2201", + "cabinet": "UC0306", + "pos": [ + 203322.0, + 438134.2 + ] + }, + { + "id": "BG3543", + "constant": "cInBG3543", + "hwAddress": "%E354.3", + "comment": "Stausensor Str.2 (KR-M2201)", + "role": "sensorJam", + "unit": "M2201", + "cabinet": "UC0306", + "pos": [ + 204250.1, + 438134.2 + ] + }, + { + "id": "BG3544", + "constant": "cInBG3544", + "hwAddress": "%E354.4", + "comment": "in Separator 1 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 204364.4, + 436279.5 + ] + }, + { + "id": "BG3545", + "constant": "cInBG3545", + "hwAddress": "%E354.5", + "comment": "Stausensor Str.1 (KR-K2206 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K2206", + "cabinet": "UC0306", + "pos": [ + 204362.7, + 435968.4 + ] + }, + { + "id": "BG3546", + "constant": "cInBG3546", + "hwAddress": "%E354.6", + "comment": "Sensor Förderer voll (ILS-CV M2206)", + "role": "sensorConvFull", + "unit": "M2206", + "cabinet": "UC0206", + "pos": [ + 204350.9, + 435329.8 + ] + }, + { + "id": "BG3547", + "constant": "cInBG3547", + "hwAddress": "%E354.7", + "comment": "Prüfung MT Pos.2 (KR-K2201 Einfahrt Block 2.2.2)", + "role": "sensorPinQuery", + "unit": "K2201", + "cabinet": "UC0306", + "pos": [ + 200286.8, + 438122.4 + ] + }, + { + "id": "BG3550", + "constant": "cInBG3550", + "hwAddress": "%E355.0", + "comment": "Prüfung MT Pos.3 (KR-K2201 Einfahrt Block 2.2.2)", + "role": "sensorPinQuery", + "unit": "K2201", + "cabinet": "UC0306", + "pos": [ + 196643.8, + 438121.0 + ] + }, + { + "id": "BG3551", + "constant": "cInBG3551", + "hwAddress": "%E355.1", + "comment": "Prüfung MT Pos.4 (KR-K2201 Einfahrt Block 2.2.2)", + "role": "sensorPinQuery", + "unit": "K2201", + "cabinet": "UC0306", + "pos": [ + 193540.2, + 438122.4 + ] + }, + { + "id": "BG3552", + "constant": "cInBG3552", + "hwAddress": "%E355.2", + "comment": "Prüfung MT Pos.5 (KR-K2201 Einfahrt Block 2.2.2)", + "role": "sensorPinQuery", + "unit": "K2201", + "cabinet": "UC0306", + "pos": [ + 189411.3, + 438122.4 + ] + }, + { + "id": "BG3553", + "constant": "cInBG3553", + "hwAddress": "%E355.3", + "comment": "Stausensor MT vor Pinband (KR-M2201) Block 2.2.2", + "role": "sensorJam", + "unit": "M2201", + "cabinet": "UC0306", + "pos": [ + 188668.8, + 438122.5 + ] + }, + { + "id": "BG3570", + "constant": "cInBG3570", + "hwAddress": "%E357.0", + "comment": "Stausensor Str.1 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 203150.0, + 436695.7 + ] + }, + { + "id": "BG3571", + "constant": "cInBG3571", + "hwAddress": "%E357.1", + "comment": "Stausensor Str.2 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 202350.0, + 436822.4 + ] + }, + { + "id": "BG3572", + "constant": "cInBG3572", + "hwAddress": "%E357.2", + "comment": "Stausensor Str.3 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 201550.0, + 436822.4 + ] + }, + { + "id": "BG3573", + "constant": "cInBG3573", + "hwAddress": "%E357.3", + "comment": "Stausensor Str.4 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 200750.1, + 436822.1 + ] + }, + { + "id": "BG3574", + "constant": "cInBG3574", + "hwAddress": "%E357.4", + "comment": "Stausensor Str.5 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 199950.0, + 436822.4 + ] + }, + { + "id": "BG3575", + "constant": "cInBG3575", + "hwAddress": "%E357.5", + "comment": "Stausensor Str.6 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 199150.0, + 436822.4 + ] + }, + { + "id": "BG3576", + "constant": "cInBG3576", + "hwAddress": "%E357.6", + "comment": "Stausensor Str.7 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 197950.0, + 436822.4 + ] + }, + { + "id": "BG3577", + "constant": "cInBG3577", + "hwAddress": "%E357.7", + "comment": "Stausensor Str.8 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 197100.2, + 436822.4 + ] + }, + { + "id": "BG3580", + "constant": "cInBG3580", + "hwAddress": "%E358.0", + "comment": "Stausensor Str.9 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 196300.1, + 436822.3 + ] + }, + { + "id": "BG3581", + "constant": "cInBG3581", + "hwAddress": "%E358.1", + "comment": "Stausensor Str.10 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 195500.2, + 436822.0 + ] + }, + { + "id": "BG3582", + "constant": "cInBG3582", + "hwAddress": "%E358.2", + "comment": "Stausensor Str.11 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 194700.1, + 436822.3 + ] + }, + { + "id": "BG3583", + "constant": "cInBG3583", + "hwAddress": "%E358.3", + "comment": "Stausensor Str.12 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 193900.1, + 436822.3 + ] + }, + { + "id": "BG3584", + "constant": "cInBG3584", + "hwAddress": "%E358.4", + "comment": "Stausensor Str.13 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 193100.2, + 436822.0 + ] + }, + { + "id": "BG3585", + "constant": "cInBG3585", + "hwAddress": "%E358.5", + "comment": "Stausensor Str.14 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 191300.0, + 436822.3 + ] + }, + { + "id": "BG3586", + "constant": "cInBG3586", + "hwAddress": "%E358.6", + "comment": "Stausensor Str.15 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 190500.0, + 436822.3 + ] + }, + { + "id": "BG3587", + "constant": "cInBG3587", + "hwAddress": "%E358.7", + "comment": "Stausensor Str.16 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 189700.1, + 436822.0 + ] + }, + { + "id": "BG3590", + "constant": "cInBG3590", + "hwAddress": "%E359.0", + "comment": "Stausensor Str.17 (Block 2.2.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0306", + "pos": [ + 188900.0, + 436822.3 + ] + }, + { + "id": "BG3600", + "constant": "cInBG3600", + "hwAddress": "%E360.0", + "comment": "in Separator 2 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 207428.1, + 436728.5 + ] + }, + { + "id": "BG3601", + "constant": "cInBG3601", + "hwAddress": "%E360.1", + "comment": "Pin Abfrage (KR-M2202 ) Block 2.2.3", + "role": "sensorPinQuery", + "unit": "M2202", + "cabinet": "UC0307", + "pos": [ + 207166.5, + 437833.0 + ] + }, + { + "id": "BG3602", + "constant": "cInBG3602", + "hwAddress": "%E360.2", + "comment": "Prüfung MT Pos.1 (KR-K2202 Einfahrt Block 2.2.3)", + "role": "sensorPinQuery", + "unit": "K2202", + "cabinet": "UC0307", + "pos": [ + 207629.1, + 438128.1 + ] + }, + { + "id": "BG3603", + "constant": "cInBG3603", + "hwAddress": "%E360.3", + "comment": "Stausensor Str.2 (KR-M2202)", + "role": "sensorJam", + "unit": "M2202", + "cabinet": "UC0307", + "pos": [ + 206622.3, + 437121.2 + ] + }, + { + "id": "BG3604", + "constant": "cInBG3604", + "hwAddress": "%E360.4", + "comment": "in Separator 1 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 206614.7, + 436163.2 + ] + }, + { + "id": "BG3605", + "constant": "cInBG3605", + "hwAddress": "%E360.5", + "comment": "Stausensor Str.1 (KR-K2207 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K2207", + "cabinet": "UC0307", + "pos": [ + 206612.9, + 435852.1 + ] + }, + { + "id": "BG3606", + "constant": "cInBG3606", + "hwAddress": "%E360.6", + "comment": "Sensor Förderer voll (ILS-CV 2207)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC0207", + "pos": [ + 206613.2, + 435231.8 + ] + }, + { + "id": "BG3607", + "constant": "cInBG3607", + "hwAddress": "%E360.7", + "comment": "Prüfung MT Pos.2 (KR-K2202 Einfahrt Block 2.2.3)", + "role": "sensorPinQuery", + "unit": "K2202", + "cabinet": "UC0307", + "pos": [ + 211110.3, + 438116.2 + ] + }, + { + "id": "BG3610", + "constant": "cInBG3610", + "hwAddress": "%E361.0", + "comment": "Prüfung MT Pos.3 (KR-K2202 Einfahrt Block 2.2.3)", + "role": "sensorPinQuery", + "unit": "K2202", + "cabinet": "UC0307", + "pos": [ + 214297.9, + 438116.2 + ] + }, + { + "id": "BG3611", + "constant": "cInBG3611", + "hwAddress": "%E361.1", + "comment": "Prüfung MT Pos.4 (KR-K2202 Einfahrt Block 2.2.3)", + "role": "sensorPinQuery", + "unit": "K2202", + "cabinet": "UC0307", + "pos": [ + 218467.2, + 438124.4 + ] + }, + { + "id": "BG3612", + "constant": "cInBG3612", + "hwAddress": "%E361.2", + "comment": "Prüfung MT Pos.5 (KR-K2202 Einfahrt Block 2.2.3)", + "role": "sensorPinQuery", + "unit": "K2202", + "cabinet": "UC0307", + "pos": [ + 221679.0, + 438116.2 + ] + }, + { + "id": "BG3613", + "constant": "cInBG3613", + "hwAddress": "%E361.3", + "comment": "Prüfung MT Pos.6 (KR-K2202 Einfahrt Block 2.2.3)", + "role": "sensorPinQuery", + "unit": "K2202", + "cabinet": "UC0307", + "pos": [ + 225266.2, + 438116.2 + ] + }, + { + "id": "BG3614", + "constant": "cInBG3614", + "hwAddress": "%E361.4", + "comment": "in Separator 3 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 227453.2, + 439228.0 + ] + }, + { + "id": "BG3615", + "constant": "cInBG3615", + "hwAddress": "%E361.5", + "comment": "Stausensor (ILS-CV M1209)", + "role": "sensorJam", + "unit": "M1209", + "cabinet": "UC0307", + "pos": [ + 226572.6, + 439215.3 + ] + }, + { + "id": "BG3616", + "constant": "cInBG3616", + "hwAddress": "%E361.6", + "comment": "Stausensor 1 (KR-M2202)", + "role": "sensorJam", + "unit": "M2202", + "cabinet": "UC0307", + "pos": [ + 225996.0, + 438549.8 + ] + }, + { + "id": "BG3617", + "constant": "cInBG3617", + "hwAddress": "%E361.7", + "comment": "in Separator 4 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 208458.9, + 438449.1 + ] + }, + { + "id": "BG3625", + "constant": "cInBG3625", + "hwAddress": "%E362.5", + "comment": "Stausensor MT vor Pinband (KR-M2202) Block 2.2.3", + "role": "sensorJam", + "unit": "M2202", + "cabinet": "UC0307", + "pos": [ + 226369.5, + 437829.1 + ] + }, + { + "id": "BG3630", + "constant": "cInBG3630", + "hwAddress": "%E363.0", + "comment": "Stausensor Str.1 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 208400.3, + 436801.8 + ] + }, + { + "id": "BG3631", + "constant": "cInBG3631", + "hwAddress": "%E363.1", + "comment": "Stausensor Str.2 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 209200.3, + 436801.7 + ] + }, + { + "id": "BG3632", + "constant": "cInBG3632", + "hwAddress": "%E363.2", + "comment": "Stausensor Str.3 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 210000.3, + 436801.7 + ] + }, + { + "id": "BG3633", + "constant": "cInBG3633", + "hwAddress": "%E363.3", + "comment": "Stausensor Str.4 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 211146.4, + 436801.7 + ] + }, + { + "id": "BG3634", + "constant": "cInBG3634", + "hwAddress": "%E363.4", + "comment": "Stausensor Str.5 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 211946.4, + 436801.7 + ] + }, + { + "id": "BG3635", + "constant": "cInBG3635", + "hwAddress": "%E363.5", + "comment": "Stausensor Str.6 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 212746.4, + 436801.7 + ] + }, + { + "id": "BG3636", + "constant": "cInBG3636", + "hwAddress": "%E363.6", + "comment": "Stausensor Str.7 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG3637", + "constant": "cInBG3637", + "hwAddress": "%E363.7", + "comment": "Stausensor Str.8 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 214346.4, + 436801.7 + ] + }, + { + "id": "BG3640", + "constant": "cInBG3640", + "hwAddress": "%E364.0", + "comment": "Stausensor Str.9 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 215146.4, + 436802.5 + ] + }, + { + "id": "BG3641", + "constant": "cInBG3641", + "hwAddress": "%E364.1", + "comment": "Stausensor Str.10 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 217150.3, + 436801.5 + ] + }, + { + "id": "BG3642", + "constant": "cInBG3642", + "hwAddress": "%E364.2", + "comment": "Stausensor Str.11 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 217950.3, + 436801.5 + ] + }, + { + "id": "BG3643", + "constant": "cInBG3643", + "hwAddress": "%E364.3", + "comment": "Stausensor Str.12 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 218750.3, + 436801.4 + ] + }, + { + "id": "BG3644", + "constant": "cInBG3644", + "hwAddress": "%E364.4", + "comment": "Stausensor Str.13 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 219549.4, + 436801.5 + ] + }, + { + "id": "BG3645", + "constant": "cInBG3645", + "hwAddress": "%E364.5", + "comment": "Stausensor Str.14 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 220350.3, + 436801.4 + ] + }, + { + "id": "BG3646", + "constant": "cInBG3646", + "hwAddress": "%E364.6", + "comment": "Stausensor Str.15 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 221150.3, + 436801.5 + ] + }, + { + "id": "BG3647", + "constant": "cInBG3647", + "hwAddress": "%E364.7", + "comment": "Stausensor Str.16 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 221950.3, + 436801.4 + ] + }, + { + "id": "BG3650", + "constant": "cInBG3650", + "hwAddress": "%E365.0", + "comment": "Stausensor Str.17 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 223150.3, + 436801.4 + ] + }, + { + "id": "BG3651", + "constant": "cInBG3651", + "hwAddress": "%E365.1", + "comment": "Stausensor Str.18 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 223950.3, + 436801.5 + ] + }, + { + "id": "BG3652", + "constant": "cInBG3652", + "hwAddress": "%E365.2", + "comment": "Stausensor Str.19 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 224748.7, + 436801.4 + ] + }, + { + "id": "BG3653", + "constant": "cInBG3653", + "hwAddress": "%E365.3", + "comment": "Stausensor Str.20 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 225550.3, + 436801.5 + ] + }, + { + "id": "BG3654", + "constant": "cInBG3654", + "hwAddress": "%E365.4", + "comment": "Stausensor Str.21 (Block 2.2.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0307", + "pos": [ + 226350.3, + 436801.5 + ] + }, + { + "id": "BG3660", + "constant": "cInBG3660", + "hwAddress": "%E366.0", + "comment": "in Separator 2 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 227619.6, + 436850.7 + ] + }, + { + "id": "BG3661", + "constant": "cInBG3661", + "hwAddress": "%E366.1", + "comment": "Pin Abfrage (KR-M2202 ) Block 2.2.4", + "role": "sensorPinQuery", + "unit": "M2202", + "cabinet": "UC0308", + "pos": [ + 227916.6, + 437830.4 + ] + }, + { + "id": "BG3662", + "constant": "cInBG3662", + "hwAddress": "%E366.2", + "comment": "Prüfung MT Pos.1 (KR-M2202 Einfahrt Block 2.2.4)", + "role": "sensorPinQuery", + "unit": "M2202", + "cabinet": "UC0308", + "pos": [ + 228749.8, + 438126.8 + ] + }, + { + "id": "BG3663", + "constant": "cInBG3663", + "hwAddress": "%E366.3", + "comment": "Stausensor Str.2 (KR-M2202)", + "role": "sensorJam", + "unit": "M2202", + "cabinet": "UC0308", + "pos": [ + 227157.2, + 437832.4 + ] + }, + { + "id": "BG3664", + "constant": "cInBG3664", + "hwAddress": "%E366.4", + "comment": "in Separator 1 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 227614.7, + 436268.5 + ] + }, + { + "id": "BG3665", + "constant": "cInBG3665", + "hwAddress": "%E366.5", + "comment": "Stausensor Str.1 (KR-K2208 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K2208", + "cabinet": "UC0308", + "pos": [ + 227613.0, + 435957.3 + ] + }, + { + "id": "BG3666", + "constant": "cInBG3666", + "hwAddress": "%E366.6", + "comment": "Sensor Förderer voll (ILS-CV 2208)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC0208", + "pos": [ + 227612.7, + 435343.3 + ] + }, + { + "id": "BG3667", + "constant": "cInBG3667", + "hwAddress": "%E366.7", + "comment": "Prüfung MT Pos.2 (KR-M2202 Einfahrt Block 2.2.4)", + "role": "sensorPinQuery", + "unit": "M2202", + "cabinet": "UC0308", + "pos": [ + 231576.8, + 438129.8 + ] + }, + { + "id": "BG3670", + "constant": "cInBG3670", + "hwAddress": "%E367.0", + "comment": "Prüfung MT Pos.3 (KR-K2202 Einfahrt Block 2.2.4)", + "role": "sensorPinQuery", + "unit": "K2202", + "cabinet": "UC0308", + "pos": [ + 234243.8, + 437126.8 + ] + }, + { + "id": "BG3671", + "constant": "cInBG3671", + "hwAddress": "%E367.1", + "comment": "Prüfung MT Pos.4 (KR-M2202 Einfahrt Block 2.2.4)", + "role": "sensorPinQuery", + "unit": "M2202", + "cabinet": "UC0308", + "pos": [ + 238060.2, + 438118.9 + ] + }, + { + "id": "BG3672", + "constant": "cInBG3672", + "hwAddress": "%E367.2", + "comment": "in Separator 3 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 241308.0, + 436806.6 + ] + }, + { + "id": "BG3673", + "constant": "cInBG3673", + "hwAddress": "%E367.3", + "comment": "Stausensor (KR-M2202)", + "role": "sensorJam", + "unit": "M2202", + "cabinet": "UC0308", + "pos": [ + 243244.3, + 438702.1 + ] + }, + { + "id": "BG3674", + "constant": "cInBG3674", + "hwAddress": "%E367.4", + "comment": "Stausensor (KR-M2202)", + "role": "sensorJam", + "unit": "M2202", + "cabinet": "UC0308", + "pos": [ + 241388.5, + 438691.8 + ] + }, + { + "id": "BG3690", + "constant": "cInBG3690", + "hwAddress": "%E369.0", + "comment": "Stausensor Str.1 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 229150.3, + 436800.9 + ] + }, + { + "id": "BG3691", + "constant": "cInBG3691", + "hwAddress": "%E369.1", + "comment": "Stausensor Str.2 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 229950.3, + 436800.8 + ] + }, + { + "id": "BG3692", + "constant": "cInBG3692", + "hwAddress": "%E369.2", + "comment": "Stausensor Str.3 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 230750.3, + 436800.8 + ] + }, + { + "id": "BG3693", + "constant": "cInBG3693", + "hwAddress": "%E369.3", + "comment": "Stausensor Str.4 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 231550.3, + 436800.7 + ] + }, + { + "id": "BG3694", + "constant": "cInBG3694", + "hwAddress": "%E369.4", + "comment": "Stausensor Str.5 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 232350.3, + 436800.7 + ] + }, + { + "id": "BG3695", + "constant": "cInBG3695", + "hwAddress": "%E369.5", + "comment": "Stausensor Str.6 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 233150.3, + 436800.8 + ] + }, + { + "id": "BG3696", + "constant": "cInBG3696", + "hwAddress": "%E369.6", + "comment": "Stausensor Str.7 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 233949.4, + 436800.7 + ] + }, + { + "id": "BG3697", + "constant": "cInBG3697", + "hwAddress": "%E369.7", + "comment": "Stausensor Str.8 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 235150.3, + 436801.5 + ] + }, + { + "id": "BG3700", + "constant": "cInBG3700", + "hwAddress": "%E370.0", + "comment": "Stausensor Str.9 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 235950.3, + 436801.5 + ] + }, + { + "id": "BG3701", + "constant": "cInBG3701", + "hwAddress": "%E370.1", + "comment": "Stausensor Str.10 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 236750.3, + 436800.6 + ] + }, + { + "id": "BG3702", + "constant": "cInBG3702", + "hwAddress": "%E370.2", + "comment": "Stausensor Str.11 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 237550.3, + 436800.6 + ] + }, + { + "id": "BG3703", + "constant": "cInBG3703", + "hwAddress": "%E370.3", + "comment": "Stausensor Str.12 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 238350.3, + 436800.5 + ] + }, + { + "id": "BG3704", + "constant": "cInBG3704", + "hwAddress": "%E370.4", + "comment": "Stausensor Str.13 (Block 2.2.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0308", + "pos": [ + 239149.4, + 436800.5 + ] + }, + { + "id": "BG3720", + "constant": "cInBG3720", + "hwAddress": "%E372.0", + "comment": "in Separator 1 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 186664.6, + 421559.5 + ] + }, + { + "id": "BG3721", + "constant": "cInBG3721", + "hwAddress": "%E372.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2205 Block 2.2.1)", + "role": "sensorJam", + "unit": "M2205", + "cabinet": "UC3201", + "pos": [ + 187300.2, + 422818.2 + ] + }, + { + "id": "BG3722", + "constant": "cInBG3722", + "hwAddress": "%E372.2", + "comment": "Stausensor 1 (KR-M2203 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M2203", + "cabinet": "UC3201", + "pos": [ + 186431.0, + 422542.8 + ] + }, + { + "id": "BG3723", + "constant": "cInBG3723", + "hwAddress": "%E372.3", + "comment": "Abfrage Mitnehmerfinger in Position (Block 2.2.1)", + "role": "sensorFinger", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 187302.9, + 423809.2 + ] + }, + { + "id": "BG3724", + "constant": "cInBG3724", + "hwAddress": "%E372.4", + "comment": "in Separator 2 (ILS-CV M2205 Block 2.2.1)", + "role": "sensorInSep", + "unit": "M2205", + "cabinet": "UC3201", + "pos": [ + 187300.2, + 423179.4 + ] + }, + { + "id": "BG3725", + "constant": "cInBG3725", + "hwAddress": "%E372.5", + "comment": "in Separator (KR-M2203)", + "role": "sensorInSep", + "unit": "M2203", + "cabinet": "UC3201", + "pos": [ + 176343.8, + 420870.2 + ] + }, + { + "id": "BG3727", + "constant": "cInBG3727", + "hwAddress": "%E372.7", + "comment": "MT in Position (ILS-CV M2205)", + "role": "sensorCarrInPos", + "unit": "M2205", + "cabinet": null, + "pos": null + }, + { + "id": "BG3750", + "constant": "cInBG3750", + "hwAddress": "%E375.0", + "comment": "in Separator 1 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 185950.0, + 423167.6 + ] + }, + { + "id": "BG3751", + "constant": "cInBG3751", + "hwAddress": "%E375.1", + "comment": "in Separator 2 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 185150.0, + 423167.6 + ] + }, + { + "id": "BG3752", + "constant": "cInBG3752", + "hwAddress": "%E375.2", + "comment": "in Separator 3 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 184350.0, + 423167.6 + ] + }, + { + "id": "BG3753", + "constant": "cInBG3753", + "hwAddress": "%E375.3", + "comment": "in Separator 4 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 183550.0, + 423167.6 + ] + }, + { + "id": "BG3754", + "constant": "cInBG3754", + "hwAddress": "%E375.4", + "comment": "in Separator 5 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 182750.0, + 423167.6 + ] + }, + { + "id": "BG3755", + "constant": "cInBG3755", + "hwAddress": "%E375.5", + "comment": "in Separator 6 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 181950.0, + 423167.6 + ] + }, + { + "id": "BG3756", + "constant": "cInBG3756", + "hwAddress": "%E375.6", + "comment": "in Separator 7 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 181150.0, + 423167.6 + ] + }, + { + "id": "BG3757", + "constant": "cInBG3757", + "hwAddress": "%E375.7", + "comment": "in Separator 8 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 179149.9, + 423167.6 + ] + }, + { + "id": "BG3760", + "constant": "cInBG3760", + "hwAddress": "%E376.0", + "comment": "in Separator 9 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 178349.9, + 423167.6 + ] + }, + { + "id": "BG3761", + "constant": "cInBG3761", + "hwAddress": "%E376.1", + "comment": "in Separator 10 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 177549.9, + 423167.6 + ] + }, + { + "id": "BG3762", + "constant": "cInBG3762", + "hwAddress": "%E376.2", + "comment": "in Separator 11 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 176749.9, + 423167.6 + ] + }, + { + "id": "BG3763", + "constant": "cInBG3763", + "hwAddress": "%E376.3", + "comment": "in Separator 12 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 175949.9, + 423167.6 + ] + }, + { + "id": "BG3764", + "constant": "cInBG3764", + "hwAddress": "%E376.4", + "comment": "in Separator 13 (Block 2.2.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3201", + "pos": [ + 175149.9, + 423167.6 + ] + }, + { + "id": "BG3780", + "constant": "cInBG3780", + "hwAddress": "%E378.0", + "comment": "in Separator 1 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 203432.0, + 421583.2 + ] + }, + { + "id": "BG3781", + "constant": "cInBG3781", + "hwAddress": "%E378.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2206)", + "role": "sensorJam", + "unit": "M2206", + "cabinet": "UC3202", + "pos": [ + 204390.8, + 422818.3 + ] + }, + { + "id": "BG3782", + "constant": "cInBG3782", + "hwAddress": "%E378.2", + "comment": "Stausensor (KR-M2203)", + "role": "sensorJam", + "unit": "M2203", + "cabinet": "UC3202", + "pos": [ + 203632.9, + 422542.9 + ] + }, + { + "id": "BG3783", + "constant": "cInBG3783", + "hwAddress": "%E378.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2206)", + "role": "sensorFinger", + "unit": "M2206", + "cabinet": "UC3202", + "pos": [ + 204393.5, + 423682.7 + ] + }, + { + "id": "BG3784", + "constant": "cInBG3784", + "hwAddress": "%E378.4", + "comment": "in Separator (ILS-CV M2206)", + "role": "sensorInSep", + "unit": "M2206", + "cabinet": "UC3202", + "pos": [ + 204390.8, + 423120.2 + ] + }, + { + "id": "BG3785", + "constant": "cInBG3785", + "hwAddress": "%E378.5", + "comment": "Stausensor 3 (KR-M2203)", + "role": "sensorJam", + "unit": "M2203", + "cabinet": "UC3202", + "pos": [ + 203727.2, + 421103.1 + ] + }, + { + "id": "BG3786", + "constant": "cInBG3786", + "hwAddress": "%E378.6", + "comment": "Rad dreht (KR-M2203)", + "role": "sensorWheel", + "unit": "M2203", + "cabinet": "UC3202", + "pos": [ + 204256.3, + 420785.7 + ] + }, + { + "id": "BG3787", + "constant": "cInBG3787", + "hwAddress": "%E378.7", + "comment": "MT in Position (ILS-CV M2206)", + "role": "sensorCarrInPos", + "unit": "M2206", + "cabinet": "UC3202", + "pos": [ + 204390.8, + 423953.4 + ] + }, + { + "id": "BG3810", + "constant": "cInBG3810", + "hwAddress": "%E381.0", + "comment": "in Separator 1 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 203151.9, + 423167.8 + ] + }, + { + "id": "BG3811", + "constant": "cInBG3811", + "hwAddress": "%E381.1", + "comment": "in Separator 2 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 202351.9, + 423167.8 + ] + }, + { + "id": "BG3812", + "constant": "cInBG3812", + "hwAddress": "%E381.2", + "comment": "in Separator 3 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 201551.9, + 423167.8 + ] + }, + { + "id": "BG3813", + "constant": "cInBG3813", + "hwAddress": "%E381.3", + "comment": "in Separator 4 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 200751.9, + 423167.8 + ] + }, + { + "id": "BG3814", + "constant": "cInBG3814", + "hwAddress": "%E381.4", + "comment": "in Separator 5 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 199951.9, + 423167.8 + ] + }, + { + "id": "BG3815", + "constant": "cInBG3815", + "hwAddress": "%E381.5", + "comment": "in Separator 6 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 199151.9, + 423167.8 + ] + }, + { + "id": "BG3816", + "constant": "cInBG3816", + "hwAddress": "%E381.6", + "comment": "in Separator 7 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 197951.9, + 423167.8 + ] + }, + { + "id": "BG3817", + "constant": "cInBG3817", + "hwAddress": "%E381.7", + "comment": "in Separator 8 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 197101.9, + 423167.8 + ] + }, + { + "id": "BG3820", + "constant": "cInBG3820", + "hwAddress": "%E382.0", + "comment": "in Separator 9 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 196301.9, + 423167.8 + ] + }, + { + "id": "BG3821", + "constant": "cInBG3821", + "hwAddress": "%E382.1", + "comment": "in Separator 10 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 195501.9, + 423167.8 + ] + }, + { + "id": "BG3822", + "constant": "cInBG3822", + "hwAddress": "%E382.2", + "comment": "in Separator 11 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 194701.9, + 423167.8 + ] + }, + { + "id": "BG3823", + "constant": "cInBG3823", + "hwAddress": "%E382.3", + "comment": "in Separator 12 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 193901.9, + 423167.8 + ] + }, + { + "id": "BG3824", + "constant": "cInBG3824", + "hwAddress": "%E382.4", + "comment": "in Separator 13 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 193101.9, + 423167.8 + ] + }, + { + "id": "BG3825", + "constant": "cInBG3825", + "hwAddress": "%E382.5", + "comment": "in Separator 14 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 191301.9, + 423167.8 + ] + }, + { + "id": "BG3826", + "constant": "cInBG3826", + "hwAddress": "%E382.6", + "comment": "in Separator 15 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 190501.9, + 423167.8 + ] + }, + { + "id": "BG3827", + "constant": "cInBG3827", + "hwAddress": "%E382.7", + "comment": "in Separator 16 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 189701.9, + 423167.8 + ] + }, + { + "id": "BG3830", + "constant": "cInBG3830", + "hwAddress": "%E383.0", + "comment": "in Separator 17 (Block 2.2.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3202", + "pos": [ + 188901.9, + 423167.8 + ] + }, + { + "id": "BG3840", + "constant": "cInBG3840", + "hwAddress": "%E384.0", + "comment": "in Separator 1 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 207906.0, + 421690.2 + ] + }, + { + "id": "BG3841", + "constant": "cInBG3841", + "hwAddress": "%E384.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2207)", + "role": "sensorJam", + "unit": "M2207", + "cabinet": "UC3203", + "pos": [ + 206541.8, + 422816.8 + ] + }, + { + "id": "BG3842", + "constant": "cInBG3842", + "hwAddress": "%E384.2", + "comment": "Stausensor (KR-M2204)", + "role": "sensorJam", + "unit": "M2204", + "cabinet": "UC3203", + "pos": [ + 207432.5, + 422541.4 + ] + }, + { + "id": "BG3843", + "constant": "cInBG3843", + "hwAddress": "%E384.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2207)", + "role": "sensorFinger", + "unit": "M2207", + "cabinet": "UC3203", + "pos": [ + 206544.5, + 423683.0 + ] + }, + { + "id": "BG3844", + "constant": "cInBG3844", + "hwAddress": "%E384.4", + "comment": "in Separator (ILS-CV M2207)", + "role": "sensorInSep", + "unit": "M2207", + "cabinet": "UC3203", + "pos": [ + 206541.8, + 423102.3 + ] + }, + { + "id": "BG3845", + "constant": "cInBG3845", + "hwAddress": "%E384.5", + "comment": "Stausensor (KR-M2204)", + "role": "sensorJam", + "unit": "M2204", + "cabinet": "UC3203", + "pos": [ + 206544.9, + 421068.8 + ] + }, + { + "id": "BG3847", + "constant": "cInBG3847", + "hwAddress": "%E384.7", + "comment": "MT in Position (ILS-CV M2207)", + "role": "sensorCarrInPos", + "unit": "M2207", + "cabinet": "UC3203", + "pos": [ + 206541.8, + 423953.6 + ] + }, + { + "id": "BG3870", + "constant": "cInBG3870", + "hwAddress": "%E387.0", + "comment": "in Separator 1 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 208401.5, + 423166.2 + ] + }, + { + "id": "BG3871", + "constant": "cInBG3871", + "hwAddress": "%E387.1", + "comment": "in Separator 2 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 209201.5, + 423166.2 + ] + }, + { + "id": "BG3872", + "constant": "cInBG3872", + "hwAddress": "%E387.2", + "comment": "in Separator 3 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 210001.5, + 423166.2 + ] + }, + { + "id": "BG3873", + "constant": "cInBG3873", + "hwAddress": "%E387.3", + "comment": "in Separator 4 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 211151.5, + 423166.2 + ] + }, + { + "id": "BG3874", + "constant": "cInBG3874", + "hwAddress": "%E387.4", + "comment": "in Separator 5 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 211951.5, + 423166.2 + ] + }, + { + "id": "BG3875", + "constant": "cInBG3875", + "hwAddress": "%E387.5", + "comment": "in Separator 6 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 212751.5, + 423166.2 + ] + }, + { + "id": "BG3876", + "constant": "cInBG3876", + "hwAddress": "%E387.6", + "comment": "in Separator 7 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 213551.5, + 423166.2 + ] + }, + { + "id": "BG3877", + "constant": "cInBG3877", + "hwAddress": "%E387.7", + "comment": "in Separator 8 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 214351.5, + 423166.2 + ] + }, + { + "id": "BG3880", + "constant": "cInBG3880", + "hwAddress": "%E388.0", + "comment": "in Separator 9 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 215151.5, + 423166.2 + ] + }, + { + "id": "BG3881", + "constant": "cInBG3881", + "hwAddress": "%E388.1", + "comment": "in Separator 10 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 217151.5, + 423166.2 + ] + }, + { + "id": "BG3882", + "constant": "cInBG3882", + "hwAddress": "%E388.2", + "comment": "in Separator 11 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 217951.5, + 423166.2 + ] + }, + { + "id": "BG3883", + "constant": "cInBG3883", + "hwAddress": "%E388.3", + "comment": "in Separator 12 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 218751.5, + 423166.2 + ] + }, + { + "id": "BG3884", + "constant": "cInBG3884", + "hwAddress": "%E388.4", + "comment": "in Separator 13 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 219551.5, + 423166.2 + ] + }, + { + "id": "BG3885", + "constant": "cInBG3885", + "hwAddress": "%E388.5", + "comment": "in Separator 14 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 220351.5, + 423166.2 + ] + }, + { + "id": "BG3886", + "constant": "cInBG3886", + "hwAddress": "%E388.6", + "comment": "in Separator 15 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 221151.5, + 423166.2 + ] + }, + { + "id": "BG3887", + "constant": "cInBG3887", + "hwAddress": "%E388.7", + "comment": "in Separator 16 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 221951.5, + 423166.2 + ] + }, + { + "id": "BG3890", + "constant": "cInBG3890", + "hwAddress": "%E389.0", + "comment": "in Separator 17 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 223151.5, + 423166.2 + ] + }, + { + "id": "BG3891", + "constant": "cInBG3891", + "hwAddress": "%E389.1", + "comment": "in Separator 18 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 223951.5, + 423166.2 + ] + }, + { + "id": "BG3892", + "constant": "cInBG3892", + "hwAddress": "%E389.2", + "comment": "in Separator 19 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 224751.5, + 423166.2 + ] + }, + { + "id": "BG3893", + "constant": "cInBG3893", + "hwAddress": "%E389.3", + "comment": "in Separator 20 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 225551.5, + 423166.2 + ] + }, + { + "id": "BG3894", + "constant": "cInBG3894", + "hwAddress": "%E389.4", + "comment": "in Separator 21 (Block 2.2.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3203", + "pos": [ + 226351.5, + 423166.2 + ] + }, + { + "id": "BG3900", + "constant": "cInBG3900", + "hwAddress": "%E390.0", + "comment": "in Separator (ILS-KR M2204)", + "role": "sensorInSep", + "unit": "M2204", + "cabinet": "UC3204", + "pos": [ + 228310.7, + 421708.2 + ] + }, + { + "id": "BG3901", + "constant": "cInBG3901", + "hwAddress": "%E390.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2208))", + "role": "sensorJam", + "unit": "M2208", + "cabinet": "UC3204", + "pos": [ + 227501.9, + 422818.2 + ] + }, + { + "id": "BG3902", + "constant": "cInBG3902", + "hwAddress": "%E390.2", + "comment": "Stausensor (KR-M2204)", + "role": "sensorJam", + "unit": "M2204", + "cabinet": "UC3204", + "pos": [ + 228273.8, + 422542.8 + ] + }, + { + "id": "BG3903", + "constant": "cInBG3903", + "hwAddress": "%E390.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2208)", + "role": "sensorFinger", + "unit": "M2208", + "cabinet": "UC3204", + "pos": [ + 227504.6, + 423678.8 + ] + }, + { + "id": "BG3904", + "constant": "cInBG3904", + "hwAddress": "%E390.4", + "comment": "in Separator (ILS-CV M2208)", + "role": "sensorInSep", + "unit": "M2208", + "cabinet": "UC3204", + "pos": [ + 227501.9, + 423123.6 + ] + }, + { + "id": "BG3905", + "constant": "cInBG3905", + "hwAddress": "%E390.5", + "comment": "in Separator 3 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 238013.9, + 421634.0 + ] + }, + { + "id": "BG3906", + "constant": "cInBG3906", + "hwAddress": "%E390.6", + "comment": "Stausensor 1 (KR-M2204)", + "role": "sensorJam", + "unit": "M2204", + "cabinet": "UC3204", + "pos": [ + 239229.7, + 421634.0 + ] + }, + { + "id": "BG3907", + "constant": "cInBG3907", + "hwAddress": "%E390.7", + "comment": "MT in Position (ILS-CV M2208)", + "role": "sensorCarrInPos", + "unit": "M2208", + "cabinet": "UC3204", + "pos": [ + 227501.9, + 423945.4 + ] + }, + { + "id": "BG3910", + "constant": "cInBG3910", + "hwAddress": "%E391.0", + "comment": "in Separator 4 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 240407.6, + 420737.9 + ] + }, + { + "id": "BG3911", + "constant": "cInBG3911", + "hwAddress": "%E391.1", + "comment": "Stausensor Einfahrt Varioförderer (M1501)", + "role": "sensorJam", + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG3912", + "constant": "cInBG3912", + "hwAddress": "%E391.2", + "comment": "in Separator 5 (ILS-CV M2209)", + "role": "sensorInSep", + "unit": "M2209", + "cabinet": "UC3204", + "pos": [ + 238124.1, + 420818.5 + ] + }, + { + "id": "BG3913", + "constant": "cInBG3913", + "hwAddress": "%E391.3", + "comment": "Sensor Förderer voll (ILS-CV 2209)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 237343.6, + 420830.6 + ] + }, + { + "id": "BG3915", + "constant": "cInBG3915", + "hwAddress": "%E391.5", + "comment": "Stausensor (ILS-CV M2209)", + "role": "sensorJam", + "unit": "M2209", + "cabinet": "UC3204", + "pos": [ + 238553.8, + 420096.9 + ] + }, + { + "id": "BG3916", + "constant": "cInBG3916", + "hwAddress": "%E391.6", + "comment": "Rad dreht (KR-M2204)", + "role": "sensorWheel", + "unit": "M2204", + "cabinet": "UC3204", + "pos": [ + 239627.0, + 422000.6 + ] + }, + { + "id": "BG3920", + "constant": "cInBG3920", + "hwAddress": "%E392.0", + "comment": "in Separator (ILS-CV M2209)", + "role": "sensorInSep", + "unit": "M2209", + "cabinet": "UC3204", + "pos": [ + 229030.0, + 269824.7 + ] + }, + { + "id": "BG3921", + "constant": "cInBG3921", + "hwAddress": "%E392.1", + "comment": "MT in Position (ILS-CV M2209)", + "role": "sensorCarrInPos", + "unit": "M2209", + "cabinet": "UC3204", + "pos": [ + 230515.0, + 269824.7 + ] + }, + { + "id": "BG3922", + "constant": "cInBG3922", + "hwAddress": "%E392.2", + "comment": "Abfrage Mitnehmerfinger in Position (CV M2209)", + "role": "sensorFinger", + "unit": "M2209", + "cabinet": "UC3204", + "pos": [ + 229775.2, + 269828.2 + ] + }, + { + "id": "BG3930", + "constant": "cInBG3930", + "hwAddress": "%E393.0", + "comment": "in Separator 1 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 229150.0, + 423167.6 + ] + }, + { + "id": "BG3931", + "constant": "cInBG3931", + "hwAddress": "%E393.1", + "comment": "in Separator 2 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 229950.0, + 423167.6 + ] + }, + { + "id": "BG3932", + "constant": "cInBG3932", + "hwAddress": "%E393.2", + "comment": "in Separator 3 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 230750.0, + 423167.6 + ] + }, + { + "id": "BG3933", + "constant": "cInBG3933", + "hwAddress": "%E393.3", + "comment": "in Separator 4 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 231550.0, + 423167.6 + ] + }, + { + "id": "BG3934", + "constant": "cInBG3934", + "hwAddress": "%E393.4", + "comment": "in Separator 5 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 232350.0, + 423167.6 + ] + }, + { + "id": "BG3935", + "constant": "cInBG3935", + "hwAddress": "%E393.5", + "comment": "in Separator 6 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 233150.0, + 423167.6 + ] + }, + { + "id": "BG3936", + "constant": "cInBG3936", + "hwAddress": "%E393.6", + "comment": "in Separator 7 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 233950.0, + 423167.6 + ] + }, + { + "id": "BG3937", + "constant": "cInBG3937", + "hwAddress": "%E393.7", + "comment": "in Separator 8 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 235150.0, + 423167.6 + ] + }, + { + "id": "BG3940", + "constant": "cInBG3940", + "hwAddress": "%E394.0", + "comment": "in Separator 9 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 235950.0, + 423167.6 + ] + }, + { + "id": "BG3941", + "constant": "cInBG3941", + "hwAddress": "%E394.1", + "comment": "in Separator 10 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 236750.0, + 423167.6 + ] + }, + { + "id": "BG3942", + "constant": "cInBG3942", + "hwAddress": "%E394.2", + "comment": "in Separator 11 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 237550.0, + 423167.6 + ] + }, + { + "id": "BG3943", + "constant": "cInBG3943", + "hwAddress": "%E394.3", + "comment": "in Separator 12 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 238350.0, + 423167.6 + ] + }, + { + "id": "BG3944", + "constant": "cInBG3944", + "hwAddress": "%E394.4", + "comment": "in Separator 13 (Block 2.2.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3204", + "pos": [ + 239150.0, + 423167.6 + ] + }, + { + "id": "BG3960", + "constant": "cInBG3960", + "hwAddress": "%E396.0", + "comment": "in Separator 1 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 186488.6, + 416652.0 + ] + }, + { + "id": "BG3961", + "constant": "cInBG3961", + "hwAddress": "%E396.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2305)", + "role": "sensorJam", + "unit": "M2305", + "cabinet": "UC3205", + "pos": [ + 187179.7, + 416348.9 + ] + }, + { + "id": "BG3962", + "constant": "cInBG3962", + "hwAddress": "%E396.2", + "comment": "Stausensor (KR-M2301)", + "role": "sensorJam", + "unit": "M2301", + "cabinet": "UC3205", + "pos": [ + 186431.0, + 417635.3 + ] + }, + { + "id": "BG3963", + "constant": "cInBG3963", + "hwAddress": "%E396.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2305)", + "role": "sensorFinger", + "unit": "M2305", + "cabinet": "UC3205", + "pos": [ + 187184.5, + 415493.4 + ] + }, + { + "id": "BG3964", + "constant": "cInBG3964", + "hwAddress": "%E396.4", + "comment": "in Separator (ILS-CV M2305)", + "role": "sensorInSep", + "unit": "M2305", + "cabinet": "UC3205", + "pos": [ + 187179.7, + 415788.0 + ] + }, + { + "id": "BG3965", + "constant": "cInBG3965", + "hwAddress": "%E396.5", + "comment": "in Separator (KR-M2301)", + "role": "sensorInSep", + "unit": "M2301", + "cabinet": "UC3205", + "pos": [ + 170987.2, + 418341.1 + ] + }, + { + "id": "BG3967", + "constant": "cInBG3967", + "hwAddress": "%E396.7", + "comment": "MT in Position (ILS-CV M2305)", + "role": "sensorCarrInPos", + "unit": "M2305", + "cabinet": "UC3205", + "pos": [ + 187181.5, + 415224.0 + ] + }, + { + "id": "BG3990", + "constant": "cInBG3990", + "hwAddress": "%E399.0", + "comment": "in Separator 1 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 185950.0, + 416041.9 + ] + }, + { + "id": "BG3991", + "constant": "cInBG3991", + "hwAddress": "%E399.1", + "comment": "in Separator 2 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 185150.0, + 416041.9 + ] + }, + { + "id": "BG3992", + "constant": "cInBG3992", + "hwAddress": "%E399.2", + "comment": "in Separator 3 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 184350.0, + 416041.9 + ] + }, + { + "id": "BG3993", + "constant": "cInBG3993", + "hwAddress": "%E399.3", + "comment": "in Separator 4 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 183550.0, + 416041.9 + ] + }, + { + "id": "BG3994", + "constant": "cInBG3994", + "hwAddress": "%E399.4", + "comment": "in Separator 5 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 182750.0, + 416041.9 + ] + }, + { + "id": "BG3995", + "constant": "cInBG3995", + "hwAddress": "%E399.5", + "comment": "in Separator 6 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 181950.0, + 416041.9 + ] + }, + { + "id": "BG3996", + "constant": "cInBG3996", + "hwAddress": "%E399.6", + "comment": "in Separator 7 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 181150.0, + 416041.9 + ] + }, + { + "id": "BG3997", + "constant": "cInBG3997", + "hwAddress": "%E399.7", + "comment": "in Separator 8 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 179149.9, + 416041.9 + ] + }, + { + "id": "BG4000", + "constant": "cInBG4000", + "hwAddress": "%E400.0", + "comment": "in Separator 9 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 178349.9, + 416041.9 + ] + }, + { + "id": "BG4001", + "constant": "cInBG4001", + "hwAddress": "%E400.1", + "comment": "in Separator 10 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 177549.9, + 416041.9 + ] + }, + { + "id": "BG4002", + "constant": "cInBG4002", + "hwAddress": "%E400.2", + "comment": "in Separator 11 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 176749.9, + 416041.9 + ] + }, + { + "id": "BG4003", + "constant": "cInBG4003", + "hwAddress": "%E400.3", + "comment": "in Separator 12 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 175949.9, + 416041.9 + ] + }, + { + "id": "BG4004", + "constant": "cInBG4004", + "hwAddress": "%E400.4", + "comment": "in Separator 13 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 175149.9, + 416041.9 + ] + }, + { + "id": "BG4005", + "constant": "cInBG4005", + "hwAddress": "%E400.5", + "comment": "in Separator 14 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 174000.0, + 416041.9 + ] + }, + { + "id": "BG4006", + "constant": "cInBG4006", + "hwAddress": "%E400.6", + "comment": "in Separator 15 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 173200.0, + 416041.9 + ] + }, + { + "id": "BG4007", + "constant": "cInBG4007", + "hwAddress": "%E400.7", + "comment": "in Separator 16 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 172400.0, + 416041.9 + ] + }, + { + "id": "BG4010", + "constant": "cInBG4010", + "hwAddress": "%E401.0", + "comment": "in Separator 17 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 171600.0, + 416041.9 + ] + }, + { + "id": "BG4011", + "constant": "cInBG4011", + "hwAddress": "%E401.1", + "comment": "in Separator 18 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 170800.0, + 416041.9 + ] + }, + { + "id": "BG4012", + "constant": "cInBG4012", + "hwAddress": "%E401.2", + "comment": "In Separator 19 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3205", + "pos": [ + 170000.0, + 416041.9 + ] + }, + { + "id": "BG4020", + "constant": "cInBG4020", + "hwAddress": "%E402.0", + "comment": "in Separator 1 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 203688.6, + 416652.0 + ] + }, + { + "id": "BG4021", + "constant": "cInBG4021", + "hwAddress": "%E402.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2306)", + "role": "sensorJam", + "unit": "M2306", + "cabinet": "UC3206", + "pos": [ + 204379.8, + 416348.9 + ] + }, + { + "id": "BG4022", + "constant": "cInBG4022", + "hwAddress": "%E402.2", + "comment": "Stausensor 1 (KR-M2301 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M2301", + "cabinet": "UC3206", + "pos": [ + 203282.3, + 417635.3 + ] + }, + { + "id": "BG4023", + "constant": "cInBG4023", + "hwAddress": "%E402.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2206)", + "role": "sensorFinger", + "unit": "M2206", + "cabinet": "UC3206", + "pos": [ + 204382.4, + 415481.7 + ] + }, + { + "id": "BG4024", + "constant": "cInBG4024", + "hwAddress": "%E402.4", + "comment": "in Separator (ILS-CV M2206)", + "role": "sensorInSep", + "unit": "M2206", + "cabinet": "UC3206", + "pos": [ + 204379.8, + 415789.7 + ] + }, + { + "id": "BG4025", + "constant": "cInBG4025", + "hwAddress": "%E402.5", + "comment": "Stausensor 2 (KR-M2301)", + "role": "sensorJam", + "unit": "M2301", + "cabinet": "UC3206", + "pos": [ + 203916.1, + 418344.7 + ] + }, + { + "id": "BG4026", + "constant": "cInBG4026", + "hwAddress": "%E402.6", + "comment": "Rad dreht (KR-M2301)", + "role": "sensorWheel", + "unit": "M2301", + "cabinet": "UC3206", + "pos": [ + 204270.7, + 418602.8 + ] + }, + { + "id": "BG4027", + "constant": "cInBG4027", + "hwAddress": "%E402.7", + "comment": "MT in Position (ILS-CV M2206)", + "role": "sensorCarrInPos", + "unit": "M2206", + "cabinet": "UC3206", + "pos": [ + 204379.5, + 415211.0 + ] + }, + { + "id": "BG4050", + "constant": "cInBG4050", + "hwAddress": "%E405.0", + "comment": "in Separator 1 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 203150.0, + 416041.9 + ] + }, + { + "id": "BG4051", + "constant": "cInBG4051", + "hwAddress": "%E405.1", + "comment": "in Separator 2 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 202350.0, + 416041.9 + ] + }, + { + "id": "BG4052", + "constant": "cInBG4052", + "hwAddress": "%E405.2", + "comment": "in Separator 3 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 201550.0, + 416041.9 + ] + }, + { + "id": "BG4053", + "constant": "cInBG4053", + "hwAddress": "%E405.3", + "comment": "in Separator 4 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 200750.0, + 416041.9 + ] + }, + { + "id": "BG4054", + "constant": "cInBG4054", + "hwAddress": "%E405.4", + "comment": "in Separator 5 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 199950.0, + 416041.9 + ] + }, + { + "id": "BG4055", + "constant": "cInBG4055", + "hwAddress": "%E405.5", + "comment": "in Separator 6 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 199150.0, + 416041.9 + ] + }, + { + "id": "BG4056", + "constant": "cInBG4056", + "hwAddress": "%E405.6", + "comment": "in Separator 7 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 197950.0, + 416041.9 + ] + }, + { + "id": "BG4057", + "constant": "cInBG4057", + "hwAddress": "%E405.7", + "comment": "in Separator 8 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 197149.9, + 416041.9 + ] + }, + { + "id": "BG4060", + "constant": "cInBG4060", + "hwAddress": "%E406.0", + "comment": "in Separator 9 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 196349.9, + 416041.9 + ] + }, + { + "id": "BG4061", + "constant": "cInBG4061", + "hwAddress": "%E406.1", + "comment": "in Separator 10 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 195549.9, + 416041.9 + ] + }, + { + "id": "BG4062", + "constant": "cInBG4062", + "hwAddress": "%E406.2", + "comment": "in Separator 11 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 194749.9, + 416041.9 + ] + }, + { + "id": "BG4063", + "constant": "cInBG4063", + "hwAddress": "%E406.3", + "comment": "in Separator 12 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 193949.9, + 416041.9 + ] + }, + { + "id": "BG4064", + "constant": "cInBG4064", + "hwAddress": "%E406.4", + "comment": "in Separator 13 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 193149.9, + 416041.9 + ] + }, + { + "id": "BG4065", + "constant": "cInBG4065", + "hwAddress": "%E406.5", + "comment": "in Separator 14 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 191300.0, + 416041.9 + ] + }, + { + "id": "BG4066", + "constant": "cInBG4066", + "hwAddress": "%E406.6", + "comment": "in Separator 15 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 190500.0, + 416041.9 + ] + }, + { + "id": "BG4067", + "constant": "cInBG4067", + "hwAddress": "%E406.7", + "comment": "in Separator 16 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 189700.0, + 416041.9 + ] + }, + { + "id": "BG4070", + "constant": "cInBG4070", + "hwAddress": "%E407.0", + "comment": "in Separator 17 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3206", + "pos": [ + 188900.0, + 416041.9 + ] + }, + { + "id": "BG4080", + "constant": "cInBG4080", + "hwAddress": "%E408.0", + "comment": "in Separator 1 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 207201.6, + 416652.0 + ] + }, + { + "id": "BG4081", + "constant": "cInBG4081", + "hwAddress": "%E408.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2308 Block 2.3.3)", + "role": "sensorJam", + "unit": "M2308", + "cabinet": "UC3207", + "pos": [ + 206548.3, + 416348.9 + ] + }, + { + "id": "BG4082", + "constant": "cInBG4082", + "hwAddress": "%E408.2", + "comment": "Stausensor 1 (KR-M2302 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M2302", + "cabinet": "UC3207", + "pos": [ + 207420.0, + 417635.3 + ] + }, + { + "id": "BG4083", + "constant": "cInBG4083", + "hwAddress": "%E408.3", + "comment": "Abfrage Mitnehmerfinger in Position (Block 2.3.3)", + "role": "sensorFinger", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 206553.0, + 415488.1 + ] + }, + { + "id": "BG4084", + "constant": "cInBG4084", + "hwAddress": "%E408.4", + "comment": "in Separator 2 (ILS-CV M2308 Block 2.3.3)", + "role": "sensorInSep", + "unit": "M2308", + "cabinet": "UC3207", + "pos": [ + 206548.3, + 415788.7 + ] + }, + { + "id": "BG4085", + "constant": "cInBG4085", + "hwAddress": "%E408.5", + "comment": "in Separator 3 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 225376.4, + 417529.0 + ] + }, + { + "id": "BG4086", + "constant": "cInBG4086", + "hwAddress": "%E408.6", + "comment": "Stausensor 2 (M2302)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 206736.1, + 418332.8 + ] + }, + { + "id": "BG4087", + "constant": "cInBG4087", + "hwAddress": "%E408.7", + "comment": "MT in Position (ILS-CV M2305)", + "role": "sensorCarrInPos", + "unit": "M2305", + "cabinet": "UC3207", + "pos": [ + 206550.4, + 415218.8 + ] + }, + { + "id": "BG4090", + "constant": "cInBG4090", + "hwAddress": "%E409.0", + "comment": "Stausensor (ILS-CV 2309)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 225234.4, + 418570.0 + ] + }, + { + "id": "BG4091", + "constant": "cInBG4091", + "hwAddress": "%E409.1", + "comment": "in Separator (ILS-CV 2309)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 226101.9, + 419498.6 + ] + }, + { + "id": "BG4092", + "constant": "cInBG4092", + "hwAddress": "%E409.2", + "comment": "Stausensor (ILS-CV 2309)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 227926.5, + 418493.7 + ] + }, + { + "id": "BG4093", + "constant": "cInBG4093", + "hwAddress": "%E409.3", + "comment": "Sensor Förderer voll (ILS-CV 2309)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 224329.3, + 418582.0 + ] + }, + { + "id": "BG4094", + "constant": "cInBG4094", + "hwAddress": "%E409.4", + "comment": "Stausensor 3 (M2302)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 226186.5, + 417799.0 + ] + }, + { + "id": "BG4095", + "constant": "cInBG4095", + "hwAddress": "%E409.5", + "comment": "in Separator 2 (ILS-CV M2309)", + "role": "sensorInSep", + "unit": "M2309", + "cabinet": "UC3207", + "pos": [ + 216706.8, + 269430.9 + ] + }, + { + "id": "BG4096", + "constant": "cInBG4096", + "hwAddress": "%E409.6", + "comment": "MT in Position (ILS-CV M2309)", + "role": "sensorCarrInPos", + "unit": "M2309", + "cabinet": "UC3207", + "pos": [ + 218191.8, + 269431.0 + ] + }, + { + "id": "BG4097", + "constant": "cInBG4097", + "hwAddress": "%E409.7", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2309)", + "role": "sensorFinger", + "unit": "M2309", + "cabinet": "UC3207", + "pos": [ + 217452.0, + 269434.4 + ] + }, + { + "id": "BG4110", + "constant": "cInBG4110", + "hwAddress": "%E411.0", + "comment": "in Separator 1 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 208401.5, + 416053.7 + ] + }, + { + "id": "BG4111", + "constant": "cInBG4111", + "hwAddress": "%E411.1", + "comment": "in Separator 2 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 209201.5, + 416053.7 + ] + }, + { + "id": "BG4112", + "constant": "cInBG4112", + "hwAddress": "%E411.2", + "comment": "in Separator 3 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 210001.5, + 416053.7 + ] + }, + { + "id": "BG4113", + "constant": "cInBG4113", + "hwAddress": "%E411.3", + "comment": "in Separator 4 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 211151.5, + 416053.7 + ] + }, + { + "id": "BG4114", + "constant": "cInBG4114", + "hwAddress": "%E411.4", + "comment": "in Separator 5 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 211951.5, + 416053.7 + ] + }, + { + "id": "BG4115", + "constant": "cInBG4115", + "hwAddress": "%E411.5", + "comment": "in Separator 6 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 212751.5, + 416053.7 + ] + }, + { + "id": "BG4116", + "constant": "cInBG4116", + "hwAddress": "%E411.6", + "comment": "in Separator 7 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 213551.5, + 416053.7 + ] + }, + { + "id": "BG4117", + "constant": "cInBG4117", + "hwAddress": "%E411.7", + "comment": "in Separator 8 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 214351.5, + 416053.7 + ] + }, + { + "id": "BG4120", + "constant": "cInBG4120", + "hwAddress": "%E412.0", + "comment": "in Separator 9 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 215151.5, + 416053.7 + ] + }, + { + "id": "BG4121", + "constant": "cInBG4121", + "hwAddress": "%E412.1", + "comment": "in Separator 10 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 217151.5, + 416053.7 + ] + }, + { + "id": "BG4122", + "constant": "cInBG4122", + "hwAddress": "%E412.2", + "comment": "in Separator 11 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 217951.5, + 416053.7 + ] + }, + { + "id": "BG4123", + "constant": "cInBG4123", + "hwAddress": "%E412.3", + "comment": "in Separator 12 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 218751.5, + 416053.7 + ] + }, + { + "id": "BG4124", + "constant": "cInBG4124", + "hwAddress": "%E412.4", + "comment": "in Separator 13 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 219551.5, + 416053.7 + ] + }, + { + "id": "BG4125", + "constant": "cInBG4125", + "hwAddress": "%E412.5", + "comment": "in Separator 14 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 220351.5, + 416053.7 + ] + }, + { + "id": "BG4126", + "constant": "cInBG4126", + "hwAddress": "%E412.6", + "comment": "in Separator 15 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 221151.5, + 416053.7 + ] + }, + { + "id": "BG4127", + "constant": "cInBG4127", + "hwAddress": "%E412.7", + "comment": "in Separator 16 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 221951.5, + 416053.7 + ] + }, + { + "id": "BG4130", + "constant": "cInBG4130", + "hwAddress": "%E413.0", + "comment": "in Separator 17 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 223151.5, + 416053.7 + ] + }, + { + "id": "BG4131", + "constant": "cInBG4131", + "hwAddress": "%E413.1", + "comment": "in Separator 18 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 223951.5, + 416053.7 + ] + }, + { + "id": "BG4132", + "constant": "cInBG4132", + "hwAddress": "%E413.2", + "comment": "in Separator 19 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 224751.5, + 416053.7 + ] + }, + { + "id": "BG4133", + "constant": "cInBG4133", + "hwAddress": "%E413.3", + "comment": "in Separator 20 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 225551.5, + 416053.7 + ] + }, + { + "id": "BG4134", + "constant": "cInBG4134", + "hwAddress": "%E413.4", + "comment": "in Separator 21 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3207", + "pos": [ + 226351.5, + 416053.7 + ] + }, + { + "id": "BG4140", + "constant": "cInBG4140", + "hwAddress": "%E414.0", + "comment": "in Separator 1 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 228201.6, + 416652.0 + ] + }, + { + "id": "BG4141", + "constant": "cInBG4141", + "hwAddress": "%E414.1", + "comment": "Staumelder, Einfahrt (ILS-CV M2308)", + "role": "sensorJam", + "unit": "M2308", + "cabinet": "UC3208", + "pos": [ + 227438.0, + 416348.9 + ] + }, + { + "id": "BG4142", + "constant": "cInBG4142", + "hwAddress": "%E414.2", + "comment": "Stausensor 1 (KR-M2302 nach BT-Beladung)", + "role": "sensorJam", + "unit": "M2302", + "cabinet": "UC3208", + "pos": [ + 228420.0, + 417635.3 + ] + }, + { + "id": "BG4143", + "constant": "cInBG4143", + "hwAddress": "%E414.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2308)", + "role": "sensorFinger", + "unit": "M2308", + "cabinet": "UC3208", + "pos": [ + 227442.7, + 415493.8 + ] + }, + { + "id": "BG4144", + "constant": "cInBG4144", + "hwAddress": "%E414.4", + "comment": "in Separator (ILS-CV M2308)", + "role": "sensorInSep", + "unit": "M2308", + "cabinet": "UC3208", + "pos": [ + 227438.0, + 415787.7 + ] + }, + { + "id": "BG4145", + "constant": "cInBG4145", + "hwAddress": "%E414.5", + "comment": "in Separator 3 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 240382.0, + 417552.1 + ] + }, + { + "id": "BG4147", + "constant": "cInBG4147", + "hwAddress": "%E414.7", + "comment": "MT in Position (ILS-CV M2308)", + "role": "sensorCarrInPos", + "unit": "M2308", + "cabinet": "UC3208", + "pos": [ + 227440.0, + 415224.5 + ] + }, + { + "id": "BG4150", + "constant": "cInBG4150", + "hwAddress": "%E415.0", + "comment": "Rad dreht (KR-M2302)", + "role": "sensorWheel", + "unit": "M2302", + "cabinet": "UC3208", + "pos": [ + 242955.6, + 417703.0 + ] + }, + { + "id": "BG4152", + "constant": "cInBG4152", + "hwAddress": "%E415.2", + "comment": "Staumelder, Einfahrt (ILS-CV M2302 Block 2.3.4)", + "role": "sensorJam", + "unit": "M2302", + "cabinet": "UC3208", + "pos": [ + 241436.8, + 418878.7 + ] + }, + { + "id": "BG4170", + "constant": "cInBG4170", + "hwAddress": "%E417.0", + "comment": "in Separator 1 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 229151.5, + 416053.7 + ] + }, + { + "id": "BG4171", + "constant": "cInBG4171", + "hwAddress": "%E417.1", + "comment": "in Separator 2 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 229951.5, + 416053.7 + ] + }, + { + "id": "BG4172", + "constant": "cInBG4172", + "hwAddress": "%E417.2", + "comment": "in Separator 3 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 230751.5, + 416053.7 + ] + }, + { + "id": "BG4173", + "constant": "cInBG4173", + "hwAddress": "%E417.3", + "comment": "in Separator 4 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 231550.0, + 416053.7 + ] + }, + { + "id": "BG4174", + "constant": "cInBG4174", + "hwAddress": "%E417.4", + "comment": "in Separator 5 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 232350.0, + 416053.7 + ] + }, + { + "id": "BG4175", + "constant": "cInBG4175", + "hwAddress": "%E417.5", + "comment": "in Separator 6 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 233150.0, + 416053.7 + ] + }, + { + "id": "BG4176", + "constant": "cInBG4176", + "hwAddress": "%E417.6", + "comment": "in Separator 7 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 233950.0, + 416053.7 + ] + }, + { + "id": "BG4177", + "constant": "cInBG4177", + "hwAddress": "%E417.7", + "comment": "in Separator 8 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 235150.0, + 416053.7 + ] + }, + { + "id": "BG4180", + "constant": "cInBG4180", + "hwAddress": "%E418.0", + "comment": "in Separator 9 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 235950.0, + 416053.7 + ] + }, + { + "id": "BG4181", + "constant": "cInBG4181", + "hwAddress": "%E418.1", + "comment": "in Separator 10 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 236751.5, + 416053.7 + ] + }, + { + "id": "BG4182", + "constant": "cInBG4182", + "hwAddress": "%E418.2", + "comment": "in Separator 11 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 237551.5, + 416053.7 + ] + }, + { + "id": "BG4183", + "constant": "cInBG4183", + "hwAddress": "%E418.3", + "comment": "in Separator 12 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 238351.5, + 416053.7 + ] + }, + { + "id": "BG4184", + "constant": "cInBG4184", + "hwAddress": "%E418.4", + "comment": "in Separator 13 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 239151.5, + 416053.7 + ] + }, + { + "id": "BG4185", + "constant": "cInBG4185", + "hwAddress": "%E418.5", + "comment": "in Separator 14 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 241151.5, + 416053.7 + ] + }, + { + "id": "BG4186", + "constant": "cInBG4186", + "hwAddress": "%E418.6", + "comment": "in Separator 15 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3208", + "pos": [ + 241951.5, + 416053.7 + ] + }, + { + "id": "BG4200", + "constant": "cInBG4200", + "hwAddress": "%E420.0", + "comment": "in Separator 2 (Block 2.3.1)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 187526.0, + 398861.1 + ] + }, + { + "id": "BG4201", + "constant": "cInBG4201", + "hwAddress": "%E420.1", + "comment": "Pin Abfrage (KR-M2303 ) Block 2.3.1", + "role": "sensorPinQuery", + "unit": "M2303", + "cabinet": "UC3301", + "pos": [ + 186867.8, + 400094.2 + ] + }, + { + "id": "BG4202", + "constant": "cInBG4202", + "hwAddress": "%E420.2", + "comment": "Prüfung MT Pos.1 (KR-K2303 Einfahrt Block 2.3.1)", + "role": "sensorPinQuery", + "unit": "K2303", + "cabinet": "UC3301", + "pos": [ + 186307.2, + 399824.2 + ] + }, + { + "id": "BG4203", + "constant": "cInBG4203", + "hwAddress": "%E420.3", + "comment": "Stausensor (KR-M2303 ) Block 2.3.1", + "role": "sensorJam", + "unit": "M2303", + "cabinet": "UC3301", + "pos": [ + 187183.8, + 399827.1 + ] + }, + { + "id": "BG4204", + "constant": "cInBG4204", + "hwAddress": "%E420.4", + "comment": "in Separator (ILS-CV 2305)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 187034.5, + 400417.1 + ] + }, + { + "id": "BG4205", + "constant": "cInBG4205", + "hwAddress": "%E420.5", + "comment": "Stausensor (ILS-CV 2305)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 187034.8, + 400991.5 + ] + }, + { + "id": "BG4206", + "constant": "cInBG4206", + "hwAddress": "%E420.6", + "comment": "Sensor Förderer voll (ILS-CV 2305)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 187037.5, + 401606.0 + ] + }, + { + "id": "BG4207", + "constant": "cInBG4207", + "hwAddress": "%E420.7", + "comment": "Prüfung MT Pos.2 (KR-K2303 Einfahrt Block 2.3.1)", + "role": "sensorPinQuery", + "unit": "K2303", + "cabinet": "UC3301", + "pos": [ + 183191.4, + 398859.2 + ] + }, + { + "id": "BG4210", + "constant": "cInBG4210", + "hwAddress": "%E421.0", + "comment": "Prüfung MT Pos.3 (KR-K2303 Einfahrt Block 2.3.1)", + "role": "sensorPinQuery", + "unit": "K2303", + "cabinet": "UC3301", + "pos": [ + 178799.9, + 398853.8 + ] + }, + { + "id": "BG4211", + "constant": "cInBG4211", + "hwAddress": "%E421.1", + "comment": "Prüfung MT Pos.4 (KR-K2303 Einfahrt Block 2.3.1)", + "role": "sensorPinQuery", + "unit": "K2303", + "cabinet": "UC3301", + "pos": [ + 175587.3, + 398853.8 + ] + }, + { + "id": "BG4212", + "constant": "cInBG4212", + "hwAddress": "%E421.2", + "comment": "Prüfung MT Pos.5 (KR-K2303 Einfahrt Block 2.3.1)", + "role": "sensorPinQuery", + "unit": "K2303", + "cabinet": "UC3301", + "pos": [ + 172113.1, + 398853.8 + ] + }, + { + "id": "BG4230", + "constant": "cInBG4230", + "hwAddress": "%E423.0", + "comment": "Stausensor Str.1 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 185951.1, + 400199.1 + ] + }, + { + "id": "BG4231", + "constant": "cInBG4231", + "hwAddress": "%E423.1", + "comment": "Stausensor Str.2 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 185150.0, + 400199.1 + ] + }, + { + "id": "BG4232", + "constant": "cInBG4232", + "hwAddress": "%E423.2", + "comment": "Stausensor Str.3 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 184349.9, + 400199.1 + ] + }, + { + "id": "BG4233", + "constant": "cInBG4233", + "hwAddress": "%E423.3", + "comment": "Stausensor Str.4 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 183550.0, + 400198.8 + ] + }, + { + "id": "BG4234", + "constant": "cInBG4234", + "hwAddress": "%E423.4", + "comment": "Stausensor Str.5 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 182749.9, + 400199.1 + ] + }, + { + "id": "BG4235", + "constant": "cInBG4235", + "hwAddress": "%E423.5", + "comment": "Stausensor Str.6 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 181949.9, + 400199.1 + ] + }, + { + "id": "BG4236", + "constant": "cInBG4236", + "hwAddress": "%E423.6", + "comment": "Stausensor Str.7 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 181150.0, + 400198.8 + ] + }, + { + "id": "BG4237", + "constant": "cInBG4237", + "hwAddress": "%E423.7", + "comment": "Stausensor Str.8 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 179149.8, + 400198.7 + ] + }, + { + "id": "BG4240", + "constant": "cInBG4240", + "hwAddress": "%E424.0", + "comment": "Stausensor Str.9 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 178349.8, + 400198.7 + ] + }, + { + "id": "BG4241", + "constant": "cInBG4241", + "hwAddress": "%E424.1", + "comment": "Stausensor Str.10 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 177549.9, + 400198.5 + ] + }, + { + "id": "BG4242", + "constant": "cInBG4242", + "hwAddress": "%E424.2", + "comment": "Stausensor Str.11 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 176749.8, + 400198.7 + ] + }, + { + "id": "BG4243", + "constant": "cInBG4243", + "hwAddress": "%E424.3", + "comment": "Stausensor Str.12 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 175949.8, + 400198.7 + ] + }, + { + "id": "BG4244", + "constant": "cInBG4244", + "hwAddress": "%E424.4", + "comment": "Stausensor Str.13 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 175149.9, + 400198.5 + ] + }, + { + "id": "BG4245", + "constant": "cInBG4245", + "hwAddress": "%E424.5", + "comment": "Stausensor Str.14 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 173999.9, + 400198.7 + ] + }, + { + "id": "BG4246", + "constant": "cInBG4246", + "hwAddress": "%E424.6", + "comment": "Stausensor Str.15 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 173199.9, + 400198.7 + ] + }, + { + "id": "BG4247", + "constant": "cInBG4247", + "hwAddress": "%E424.7", + "comment": "Stausensor Str.16 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 172400.0, + 400198.5 + ] + }, + { + "id": "BG4250", + "constant": "cInBG4250", + "hwAddress": "%E425.0", + "comment": "Stausensor Str.17 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 171599.9, + 400198.7 + ] + }, + { + "id": "BG4251", + "constant": "cInBG4251", + "hwAddress": "%E425.1", + "comment": "Stausensor Str.18 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 170799.9, + 400198.7 + ] + }, + { + "id": "BG4252", + "constant": "cInBG4252", + "hwAddress": "%E425.2", + "comment": "Stausensor Str.19 (Block 2.3.1)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3301", + "pos": [ + 170000.0, + 400198.5 + ] + }, + { + "id": "BG4260", + "constant": "cInBG4260", + "hwAddress": "%E426.0", + "comment": "in Separator 2 (Block 2.3.2)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 204280.0, + 398835.2 + ] + }, + { + "id": "BG4261", + "constant": "cInBG4261", + "hwAddress": "%E426.1", + "comment": "Pin Abfrage (KR-M2303 ) Block 2.3.2", + "role": "sensorPinQuery", + "unit": "M2303", + "cabinet": "UC3302", + "pos": [ + 203763.4, + 400128.2 + ] + }, + { + "id": "BG4262", + "constant": "cInBG4262", + "hwAddress": "%E426.2", + "comment": "Prüfung MT Pos.1 (KR-K2303 Einfahrt Block 2.3.2)", + "role": "sensorPinQuery", + "unit": "K2303", + "cabinet": "UC3302", + "pos": [ + 203592.6, + 399808.7 + ] + }, + { + "id": "BG4263", + "constant": "cInBG4263", + "hwAddress": "%E426.3", + "comment": "Stausensor (KR-M2303)", + "role": "sensorJam", + "unit": "M2303", + "cabinet": "UC3302", + "pos": [ + 204499.3, + 399939.0 + ] + }, + { + "id": "BG4264", + "constant": "cInBG4264", + "hwAddress": "%E426.4", + "comment": "in Separator (ILS-CV 2306)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 204234.5, + 400417.1 + ] + }, + { + "id": "BG4265", + "constant": "cInBG4265", + "hwAddress": "%E426.5", + "comment": "Stausensor (ILS-CV 2306)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 204234.8, + 400991.5 + ] + }, + { + "id": "BG4266", + "constant": "cInBG4266", + "hwAddress": "%E426.6", + "comment": "Sensor Förderer voll (ILS-CV 2306)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 204234.8, + 401597.2 + ] + }, + { + "id": "BG4267", + "constant": "cInBG4267", + "hwAddress": "%E426.7", + "comment": "Prüfung MT Pos.2 (KR-K2303 Einfahrt Block 2.3.2)", + "role": "sensorPinQuery", + "unit": "K2303", + "cabinet": "UC3302", + "pos": [ + 200391.4, + 398859.2 + ] + }, + { + "id": "BG4270", + "constant": "cInBG4270", + "hwAddress": "%E427.0", + "comment": "Prüfung MT Pos.3 (KR-K2303 Einfahrt Block 2.3.2)", + "role": "sensorPinQuery", + "unit": "K2303", + "cabinet": "UC3302", + "pos": [ + 196799.9, + 398853.8 + ] + }, + { + "id": "BG4271", + "constant": "cInBG4271", + "hwAddress": "%E427.1", + "comment": "Prüfung MT Pos.4 (KR-K2303 Einfahrt Block 2.3.2)", + "role": "sensorPinQuery", + "unit": "K2303", + "cabinet": "UC3302", + "pos": [ + 193587.3, + 398853.8 + ] + }, + { + "id": "BG4272", + "constant": "cInBG4272", + "hwAddress": "%E427.2", + "comment": "Prüfung MT Pos.5 (KR-K2303 Einfahrt Block 2.3.2)", + "role": "sensorPinQuery", + "unit": "K2303", + "cabinet": "UC3302", + "pos": [ + 189413.6, + 398853.8 + ] + }, + { + "id": "BG4273", + "constant": "cInBG4273", + "hwAddress": "%E427.3", + "comment": "Stausensor MT vor Pinband (KR-K2303) Block 2.3.2", + "role": "sensorJam", + "unit": "K2303", + "cabinet": "UC3302", + "pos": [ + 188610.7, + 398854.0 + ] + }, + { + "id": "BG4290", + "constant": "cInBG4290", + "hwAddress": "%E429.0", + "comment": "Stausensor Str.1 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 203159.8, + 400437.1 + ] + }, + { + "id": "BG4291", + "constant": "cInBG4291", + "hwAddress": "%E429.1", + "comment": "Stausensor Str.2 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 202350.0, + 400199.1 + ] + }, + { + "id": "BG4292", + "constant": "cInBG4292", + "hwAddress": "%E429.2", + "comment": "Stausensor Str.3 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 201549.9, + 400199.1 + ] + }, + { + "id": "BG4293", + "constant": "cInBG4293", + "hwAddress": "%E429.3", + "comment": "Stausensor Str.4 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 200750.0, + 400198.8 + ] + }, + { + "id": "BG4294", + "constant": "cInBG4294", + "hwAddress": "%E429.4", + "comment": "Stausensor Str.5 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 199949.9, + 400199.1 + ] + }, + { + "id": "BG4295", + "constant": "cInBG4295", + "hwAddress": "%E429.5", + "comment": "Stausensor Str.6 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 199149.9, + 400199.1 + ] + }, + { + "id": "BG4296", + "constant": "cInBG4296", + "hwAddress": "%E429.6", + "comment": "Stausensor Str.7 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 197950.0, + 400198.8 + ] + }, + { + "id": "BG4297", + "constant": "cInBG4297", + "hwAddress": "%E429.7", + "comment": "Stausensor Str.8 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 197149.8, + 400198.7 + ] + }, + { + "id": "BG4300", + "constant": "cInBG4300", + "hwAddress": "%E430.0", + "comment": "Stausensor Str.9 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 196349.8, + 400198.7 + ] + }, + { + "id": "BG4301", + "constant": "cInBG4301", + "hwAddress": "%E430.1", + "comment": "Stausensor Str.10 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 195549.9, + 400198.5 + ] + }, + { + "id": "BG4302", + "constant": "cInBG4302", + "hwAddress": "%E430.2", + "comment": "Stausensor Str.11 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 194749.8, + 400198.7 + ] + }, + { + "id": "BG4303", + "constant": "cInBG4303", + "hwAddress": "%E430.3", + "comment": "Stausensor Str.12 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 193949.8, + 400198.7 + ] + }, + { + "id": "BG4304", + "constant": "cInBG4304", + "hwAddress": "%E430.4", + "comment": "Stausensor Str.13 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 193149.9, + 400198.5 + ] + }, + { + "id": "BG4305", + "constant": "cInBG4305", + "hwAddress": "%E430.5", + "comment": "Stausensor Str.14 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 191299.9, + 400198.7 + ] + }, + { + "id": "BG4306", + "constant": "cInBG4306", + "hwAddress": "%E430.6", + "comment": "Stausensor Str.15 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 190499.9, + 400198.7 + ] + }, + { + "id": "BG4307", + "constant": "cInBG4307", + "hwAddress": "%E430.7", + "comment": "Stausensor Str.16 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 189700.0, + 400198.5 + ] + }, + { + "id": "BG4310", + "constant": "cInBG4310", + "hwAddress": "%E431.0", + "comment": "Stausensor Str.17 (Block 2.3.2)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3302", + "pos": [ + 188899.9, + 400198.7 + ] + }, + { + "id": "BG4320", + "constant": "cInBG4320", + "hwAddress": "%E432.0", + "comment": "in Separator 2 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 207436.2, + 398763.1 + ] + }, + { + "id": "BG4321", + "constant": "cInBG4321", + "hwAddress": "%E432.1", + "comment": "Pin Abfrage (KR-M2304) Block 2.3.3", + "role": "sensorPinQuery", + "unit": "M2304", + "cabinet": "UC3303", + "pos": [ + 207172.5, + 400128.3 + ] + }, + { + "id": "BG4322", + "constant": "cInBG4322", + "hwAddress": "%E432.2", + "comment": "Prüfung MT Pos.1 (KR-K2304 Einfahrt Block 2.3.3)", + "role": "sensorPinQuery", + "unit": "K2304", + "cabinet": "UC3303", + "pos": [ + 207454.4, + 399808.7 + ] + }, + { + "id": "BG4323", + "constant": "cInBG4323", + "hwAddress": "%E432.3", + "comment": "Stausensor (KR-M2304)", + "role": "sensorJam", + "unit": "M2304", + "cabinet": "UC3303", + "pos": [ + 206399.7, + 399948.7 + ] + }, + { + "id": "BG4324", + "constant": "cInBG4324", + "hwAddress": "%E432.4", + "comment": "in Separator 1 (ILS-CV 2307)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 206399.4, + 400428.3 + ] + }, + { + "id": "BG4325", + "constant": "cInBG4325", + "hwAddress": "%E432.5", + "comment": "Stausensor Str.1 (KR-K2307 vor BT-Beladung)", + "role": "sensorJam", + "unit": "K2307", + "cabinet": "UC3303", + "pos": [ + 206399.7, + 401002.7 + ] + }, + { + "id": "BG4326", + "constant": "cInBG4326", + "hwAddress": "%E432.6", + "comment": "Sensor Förderer voll (ILS-CV 2307)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 206399.7, + 401629.7 + ] + }, + { + "id": "BG4327", + "constant": "cInBG4327", + "hwAddress": "%E432.7", + "comment": "Prüfung MT Pos.2 (KR-K2304 Einfahrt Block 2.3.3)", + "role": "sensorPinQuery", + "unit": "K2304", + "cabinet": "UC3303", + "pos": [ + 211112.4, + 398849.9 + ] + }, + { + "id": "BG4330", + "constant": "cInBG4330", + "hwAddress": "%E433.0", + "comment": "Prüfung MT Pos.3 (KR-K2304 Einfahrt Block 2.3.3)", + "role": "sensorPinQuery", + "unit": "K2304", + "cabinet": "UC3303", + "pos": [ + 214467.8, + 398847.2 + ] + }, + { + "id": "BG4331", + "constant": "cInBG4331", + "hwAddress": "%E433.1", + "comment": "Prüfung MT Pos.4 (KR-K2304 Einfahrt Block 2.3.3)", + "role": "sensorPinQuery", + "unit": "K2304", + "cabinet": "UC3303", + "pos": [ + 218467.0, + 398849.9 + ] + }, + { + "id": "BG4332", + "constant": "cInBG4332", + "hwAddress": "%E433.2", + "comment": "Prüfung MT Pos.5 (KR-K2304 Einfahrt Block 2.3.3)", + "role": "sensorPinQuery", + "unit": "K2304", + "cabinet": "UC3303", + "pos": [ + 221675.6, + 398849.9 + ] + }, + { + "id": "BG4333", + "constant": "cInBG4333", + "hwAddress": "%E433.3", + "comment": "Prüfung MT Pos.6 (KR-K2304 Einfahrt Block 2.3.3)", + "role": "sensorPinQuery", + "unit": "K2304", + "cabinet": "UC3303", + "pos": [ + 225264.8, + 398869.6 + ] + }, + { + "id": "BG4334", + "constant": "cInBG4334", + "hwAddress": "%E433.4", + "comment": "in Separator 3 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 226182.6, + 397653.7 + ] + }, + { + "id": "BG4335", + "constant": "cInBG4335", + "hwAddress": "%E433.5", + "comment": "Stausensor 1 (M2309)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 224320.9, + 398247.3 + ] + }, + { + "id": "BG4336", + "constant": "cInBG4336", + "hwAddress": "%E433.6", + "comment": "Stausensor 1 (M2309)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 224762.2, + 398517.3 + ] + }, + { + "id": "BG4337", + "constant": "cInBG4337", + "hwAddress": "%E433.7", + "comment": "in Separator 1 (Block 2.3.3)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 206958.8, + 398144.5 + ] + }, + { + "id": "BG4350", + "constant": "cInBG4350", + "hwAddress": "%E435.0", + "comment": "Stausensor Str.1 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 208400.0, + 400204.6 + ] + }, + { + "id": "BG4351", + "constant": "cInBG4351", + "hwAddress": "%E435.1", + "comment": "Stausensor Str.2 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 209200.0, + 400204.6 + ] + }, + { + "id": "BG4352", + "constant": "cInBG4352", + "hwAddress": "%E435.2", + "comment": "Stausensor Str.3 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 210000.0, + 400204.6 + ] + }, + { + "id": "BG4353", + "constant": "cInBG4353", + "hwAddress": "%E435.3", + "comment": "Stausensor Str.4 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 211146.1, + 400204.5 + ] + }, + { + "id": "BG4354", + "constant": "cInBG4354", + "hwAddress": "%E435.4", + "comment": "Stausensor Str.5 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 211946.1, + 400204.5 + ] + }, + { + "id": "BG4355", + "constant": "cInBG4355", + "hwAddress": "%E435.5", + "comment": "Stausensor Str.6 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 212746.1, + 400204.6 + ] + }, + { + "id": "BG4356", + "constant": "cInBG4356", + "hwAddress": "%E435.6", + "comment": "Stausensor Str.7 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 213545.3, + 400204.5 + ] + }, + { + "id": "BG4357", + "constant": "cInBG4357", + "hwAddress": "%E435.7", + "comment": "Stausensor Str.8 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 214346.1, + 400204.5 + ] + }, + { + "id": "BG4360", + "constant": "cInBG4360", + "hwAddress": "%E436.0", + "comment": "Stausensor Str.9 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 215146.1, + 400205.3 + ] + }, + { + "id": "BG4361", + "constant": "cInBG4361", + "hwAddress": "%E436.1", + "comment": "Stausensor Str.10 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 217150.0, + 400204.3 + ] + }, + { + "id": "BG4362", + "constant": "cInBG4362", + "hwAddress": "%E436.2", + "comment": "Stausensor Str.11 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 217950.0, + 400204.3 + ] + }, + { + "id": "BG4363", + "constant": "cInBG4363", + "hwAddress": "%E436.3", + "comment": "Stausensor Str.12 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 218750.0, + 400204.3 + ] + }, + { + "id": "BG4364", + "constant": "cInBG4364", + "hwAddress": "%E436.4", + "comment": "Stausensor Str.13 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 219549.1, + 400204.3 + ] + }, + { + "id": "BG4365", + "constant": "cInBG4365", + "hwAddress": "%E436.5", + "comment": "Stausensor Str.14 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 220350.0, + 400204.3 + ] + }, + { + "id": "BG4366", + "constant": "cInBG4366", + "hwAddress": "%E436.6", + "comment": "Stausensor Str.15 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 221150.0, + 400204.3 + ] + }, + { + "id": "BG4367", + "constant": "cInBG4367", + "hwAddress": "%E436.7", + "comment": "Stausensor Str.16 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 221950.0, + 400204.3 + ] + }, + { + "id": "BG4370", + "constant": "cInBG4370", + "hwAddress": "%E437.0", + "comment": "Stausensor Str.17 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 223150.0, + 400204.3 + ] + }, + { + "id": "BG4371", + "constant": "cInBG4371", + "hwAddress": "%E437.1", + "comment": "Stausensor Str.18 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 223950.0, + 400204.3 + ] + }, + { + "id": "BG4372", + "constant": "cInBG4372", + "hwAddress": "%E437.2", + "comment": "Stausensor Str.19 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 224748.4, + 400204.3 + ] + }, + { + "id": "BG4373", + "constant": "cInBG4373", + "hwAddress": "%E437.3", + "comment": "Stausensor Str.20 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 225550.0, + 400204.3 + ] + }, + { + "id": "BG4374", + "constant": "cInBG4374", + "hwAddress": "%E437.4", + "comment": "Stausensor Str.21 (Block 2.3.3)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3303", + "pos": [ + 226292.5, + 400204.3 + ] + }, + { + "id": "BG4375", + "constant": "cInBG4375", + "hwAddress": "%E437.5", + "comment": "Stausensor MT vor Pinband (KR-K2304) Block 2.3.3)", + "role": "sensorJam", + "unit": "K2304", + "cabinet": "UC3303", + "pos": [ + 226369.5, + 399160.8 + ] + }, + { + "id": "BG4380", + "constant": "cInBG4380", + "hwAddress": "%E438.0", + "comment": "in Separator 2 (Block 2.3.4)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 227459.1, + 398874.9 + ] + }, + { + "id": "BG4381", + "constant": "cInBG4381", + "hwAddress": "%E438.1", + "comment": "Pin Abfrage (KR-M2304) Block 2.3.4", + "role": "sensorPinQuery", + "unit": "M2304", + "cabinet": "UC3304", + "pos": [ + 228109.8, + 400128.3 + ] + }, + { + "id": "BG4382", + "constant": "cInBG4382", + "hwAddress": "%E438.2", + "comment": "Prüfung MT Pos.1 (KR-K2304 Einfahrt Block 2.3.4)", + "role": "sensorPinQuery", + "unit": "K2304", + "cabinet": "UC3304", + "pos": [ + 228296.5, + 399808.7 + ] + }, + { + "id": "BG4383", + "constant": "cInBG4383", + "hwAddress": "%E438.3", + "comment": "Stausensor (KR-M2304)", + "role": "sensorJam", + "unit": "M2304", + "cabinet": "UC3304", + "pos": [ + 227343.2, + 400128.5 + ] + }, + { + "id": "BG4384", + "constant": "cInBG4384", + "hwAddress": "%E438.4", + "comment": "in Separator 1 (ILS-CV M2308)", + "role": "sensorInSep", + "unit": "M2308", + "cabinet": "UC3304", + "pos": [ + 227555.6, + 400428.3 + ] + }, + { + "id": "BG4385", + "constant": "cInBG4385", + "hwAddress": "%E438.5", + "comment": "Stausensor (ILS-CV M2308)", + "role": "sensorJam", + "unit": "M2308", + "cabinet": "UC3304", + "pos": [ + 227555.9, + 401002.7 + ] + }, + { + "id": "BG4386", + "constant": "cInBG4386", + "hwAddress": "%E438.6", + "comment": "Sensor Förderer voll (ILS-CV 2308)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 227558.6, + 401614.7 + ] + }, + { + "id": "BG4387", + "constant": "cInBG4387", + "hwAddress": "%E438.7", + "comment": "Prüfung MT Pos.2 (KR-K2304 Einfahrt Block 2.3.4)", + "role": "sensorPinQuery", + "unit": "K2304", + "cabinet": "UC3304", + "pos": [ + 231954.5, + 398849.9 + ] + }, + { + "id": "BG4390", + "constant": "cInBG4390", + "hwAddress": "%E439.0", + "comment": "Prüfung MT Pos.3 (KR-K2304 Einfahrt Block 2.3.4)", + "role": "sensorPinQuery", + "unit": "K2304", + "cabinet": "UC3304", + "pos": [ + 235175.7, + 398845.0 + ] + }, + { + "id": "BG4391", + "constant": "cInBG4391", + "hwAddress": "%E439.1", + "comment": "Prüfung MT Pos.4 (KR-K2304 Einfahrt Block 2.3.4)", + "role": "sensorPinQuery", + "unit": "K2304", + "cabinet": "UC3304", + "pos": [ + 238336.8, + 398849.9 + ] + }, + { + "id": "BG4392", + "constant": "cInBG4392", + "hwAddress": "%E439.2", + "comment": "Stausensor 3 (M2302)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 241444.5, + 398378.8 + ] + }, + { + "id": "BG4395", + "constant": "cInBG4395", + "hwAddress": "%E439.5", + "comment": "in Separator 1 (KR-K2210 Block 2.3.4)", + "role": "sensorInSep", + "unit": "K2210", + "cabinet": "UC3304", + "pos": [ + 242293.8, + 400551.2 + ] + }, + { + "id": "BG4396", + "constant": "cInBG4396", + "hwAddress": "%E439.6", + "comment": "Rad dreht (KR-K2210)", + "role": "sensorWheel", + "unit": "K2210", + "cabinet": "UC3304", + "pos": [ + 243631.4, + 398384.4 + ] + }, + { + "id": "BG4410", + "constant": "cInBG4410", + "hwAddress": "%E441.0", + "comment": "Stausensor Str.1 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 229150.0, + 400204.6 + ] + }, + { + "id": "BG4411", + "constant": "cInBG4411", + "hwAddress": "%E441.1", + "comment": "Stausensor Str.2 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 229950.0, + 400204.6 + ] + }, + { + "id": "BG4412", + "constant": "cInBG4412", + "hwAddress": "%E441.2", + "comment": "Stausensor Str.3 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 230750.0, + 400204.6 + ] + }, + { + "id": "BG4413", + "constant": "cInBG4413", + "hwAddress": "%E441.3", + "comment": "Stausensor Str.4 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 231550.0, + 400201.3 + ] + }, + { + "id": "BG4414", + "constant": "cInBG4414", + "hwAddress": "%E441.4", + "comment": "Stausensor Str.5 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 232350.0, + 400201.3 + ] + }, + { + "id": "BG4415", + "constant": "cInBG4415", + "hwAddress": "%E441.5", + "comment": "Stausensor Str.6 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 233150.0, + 400201.4 + ] + }, + { + "id": "BG4416", + "constant": "cInBG4416", + "hwAddress": "%E441.6", + "comment": "Stausensor Str.7 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 233949.1, + 400201.3 + ] + }, + { + "id": "BG4417", + "constant": "cInBG4417", + "hwAddress": "%E441.7", + "comment": "Stausensor Str.8 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 235150.0, + 400201.3 + ] + }, + { + "id": "BG4420", + "constant": "cInBG4420", + "hwAddress": "%E442.0", + "comment": "Stausensor Str.9 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 235950.0, + 400202.1 + ] + }, + { + "id": "BG4421", + "constant": "cInBG4421", + "hwAddress": "%E442.1", + "comment": "Stausensor Str.10 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 236750.0, + 400204.3 + ] + }, + { + "id": "BG4422", + "constant": "cInBG4422", + "hwAddress": "%E442.2", + "comment": "Stausensor Str.11 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 237550.0, + 400204.3 + ] + }, + { + "id": "BG4423", + "constant": "cInBG4423", + "hwAddress": "%E442.3", + "comment": "Stausensor Str.12 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 238350.0, + 400204.3 + ] + }, + { + "id": "BG4424", + "constant": "cInBG4424", + "hwAddress": "%E442.4", + "comment": "Stausensor Str.13 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 239149.1, + 400204.3 + ] + }, + { + "id": "BG4425", + "constant": "cInBG4425", + "hwAddress": "%E442.5", + "comment": "Stausensor Str.14 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 241149.1, + 400204.3 + ] + }, + { + "id": "BG4426", + "constant": "cInBG4426", + "hwAddress": "%E442.6", + "comment": "Stausensor Str.15 (Block 2.3.4)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC3304", + "pos": [ + 241949.1, + 400204.3 + ] + }, + { + "id": "BG4440", + "constant": "cInBG4440", + "hwAddress": "%E444.0", + "comment": "in Separator 1 (ILS-CV 2111)", + "role": "sensorInSep", + "unit": null, + "cabinet": "UC0309", + "pos": [ + 244310.6, + 457678.9 + ] + }, + { + "id": "BG4441", + "constant": "cInBG4441", + "hwAddress": "%E444.1", + "comment": "Stausensor (ILS-CV 2111)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0309", + "pos": [ + 245289.1, + 458961.4 + ] + }, + { + "id": "BG4442", + "constant": "cInBG4442", + "hwAddress": "%E444.2", + "comment": "Sensor Förderer voll (ILS-CV 2111)", + "role": "sensorConvFull", + "unit": null, + "cabinet": "UC0309", + "pos": [ + 246774.1, + 458961.2 + ] + }, + { + "id": "BG4443", + "constant": "cInBG4443", + "hwAddress": "%E444.3", + "comment": "Stausensor 2 ((KR-K2110)", + "role": "sensorJam", + "unit": "K2110", + "cabinet": null, + "pos": null + }, + { + "id": "BG4444", + "constant": "cInBG4444", + "hwAddress": "%E444.4", + "comment": "in Separator 3 (KR-K2110)", + "role": "sensorInSep", + "unit": "K2110", + "cabinet": "UC0309", + "pos": [ + 242270.9, + 457166.7 + ] + }, + { + "id": "BG4450", + "constant": "cInBG4450", + "hwAddress": "%E445.0", + "comment": "in Separator (ILS-CV M2111)", + "role": "sensorInSep", + "unit": "M2111", + "cabinet": "UC0309", + "pos": [ + 239864.5, + 152557.1 + ] + }, + { + "id": "BG4451", + "constant": "cInBG4451", + "hwAddress": "%E445.1", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M2111)", + "role": "sensorFinger", + "unit": "M2111", + "cabinet": "UC0309", + "pos": [ + 239867.2, + 153134.1 + ] + }, + { + "id": "BG4452", + "constant": "cInBG4452", + "hwAddress": "%E445.2", + "comment": "MT in Position (ILS-CV M2111)", + "role": "sensorCarrInPos", + "unit": "M2111", + "cabinet": "UC0309", + "pos": [ + 239864.5, + 153429.9 + ] + }, + { + "id": "BG4500", + "constant": "cInBG4500", + "hwAddress": "%E450.0", + "comment": "in Separator 1 (KR-M2110)", + "role": "sensorInSep", + "unit": "M2110", + "cabinet": "UC0310", + "pos": [ + 243528.6, + 436159.0 + ] + }, + { + "id": "BG4503", + "constant": "cInBG4503", + "hwAddress": "%E450.3", + "comment": "in Separator 2 (KR-M2110)", + "role": "sensorInSep", + "unit": "M2110", + "cabinet": "UC0310", + "pos": [ + 244342.1, + 431035.2 + ] + }, + { + "id": "BG4504", + "constant": "cInBG4504", + "hwAddress": "%E450.4", + "comment": "Stausensor 1 (KR-M2110)", + "role": "sensorJam", + "unit": "M2110", + "cabinet": "UC0310", + "pos": [ + 242299.4, + 430894.2 + ] + }, + { + "id": "BG4505", + "constant": "cInBG4505", + "hwAddress": "%E450.5", + "comment": "Rad dreht (KR-M2110)", + "role": "sensorWheel", + "unit": "M2110", + "cabinet": "UC0310", + "pos": [ + 242290.2, + 430492.5 + ] + }, + { + "id": "BG4507", + "constant": "cInBG4507", + "hwAddress": "%E450.7", + "comment": "Stausensor 3 (KR-K2210)", + "role": "sensorJam", + "unit": "K2210", + "cabinet": "UC0310", + "pos": [ + 242289.3, + 429507.7 + ] + }, + { + "id": "BG4560", + "constant": "cInBG4560", + "hwAddress": "%E456.0", + "comment": "in Separator 1 (KR-M2110)", + "role": "sensorInSep", + "unit": "M2110", + "cabinet": "UC0311", + "pos": [ + 243083.2, + 448714.8 + ] + }, + { + "id": "BG4561", + "constant": "cInBG4561", + "hwAddress": "%E456.1", + "comment": "Teil auf MT (Sep 3MB4560)", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG4562", + "constant": "cInBG4562", + "hwAddress": "%E456.2", + "comment": "in Separator 1 (ILS-CV M4101)", + "role": "sensorInSep", + "unit": "M4101", + "cabinet": "UC0311", + "pos": [ + 245255.0, + 448215.6 + ] + }, + { + "id": "BG4563", + "constant": "cInBG4563", + "hwAddress": "%E456.3", + "comment": "Stausensor 1 (ILS-CV M4201)", + "role": "sensorJam", + "unit": "M4201", + "cabinet": "UC0311", + "pos": [ + 246452.5, + 447225.5 + ] + }, + { + "id": "BG4564", + "constant": "cInBG4564", + "hwAddress": "%E456.4", + "comment": "Stausensor 1 (ILS-CV M4101)", + "role": "sensorJam", + "unit": "M4101", + "cabinet": "UC0311", + "pos": [ + 246548.2, + 448416.1 + ] + }, + { + "id": "BG4565", + "constant": "cInBG4565", + "hwAddress": "%E456.5", + "comment": "Sensor Förderer voll (ILS-CV M4101)", + "role": "sensorConvFull", + "unit": "M4101", + "cabinet": "UC0311", + "pos": [ + 248034.8, + 448429.4 + ] + }, + { + "id": "BG4566", + "constant": "cInBG4566", + "hwAddress": "%E456.6", + "comment": "in Separator 2 (ILS-CV M4101)", + "role": "sensorInSep", + "unit": "M4101", + "cabinet": "UC0311", + "pos": [ + 250493.0, + 448413.4 + ] + }, + { + "id": "BG4567", + "constant": "cInBG4567", + "hwAddress": "%E456.7", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4101)", + "role": "sensorFinger", + "unit": "M4101", + "cabinet": "UC0311", + "pos": [ + 249730.2, + 448419.5 + ] + }, + { + "id": "BG4570", + "constant": "cInBG4570", + "hwAddress": "%E457.0", + "comment": "MT in Position (ILS-CV M4101)", + "role": "sensorCarrInPos", + "unit": "M4101", + "cabinet": "UC0311", + "pos": [ + 248985.0, + 448416.1 + ] + }, + { + "id": "BG4571", + "constant": "cInBG4571", + "hwAddress": "%E457.1", + "comment": "MT in Position (ILS-CV M4201)", + "role": "sensorCarrInPos", + "unit": "M4201", + "cabinet": "UC0311", + "pos": [ + 248615.9, + 446409.7 + ] + }, + { + "id": "BG4572", + "constant": "cInBG4572", + "hwAddress": "%E457.2", + "comment": "in Separator 1 (ILS-CV M4201)", + "role": "sensorInSep", + "unit": "M4201", + "cabinet": "UC0311", + "pos": [ + 250526.1, + 446139.7 + ] + }, + { + "id": "BG4573", + "constant": "cInBG4573", + "hwAddress": "%E457.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4201)", + "role": "sensorFinger", + "unit": "M4201", + "cabinet": "UC0311", + "pos": [ + 249758.2, + 446151.7 + ] + }, + { + "id": "BG4574", + "constant": "cInBG4574", + "hwAddress": "%E457.4", + "comment": "Sensor Förderer voll (ILS-CV M4201)", + "role": "sensorConvFull", + "unit": "M4201", + "cabinet": "UC0311", + "pos": [ + 247197.7, + 447228.9 + ] + }, + { + "id": "BG4575", + "constant": "cInBG4575", + "hwAddress": "%E457.5", + "comment": "in Separator 2 (ILS-CV M4201)", + "role": "sensorInSep", + "unit": "M4201", + "cabinet": "UC0311", + "pos": [ + 245419.1, + 446942.4 + ] + }, + { + "id": "BG4576", + "constant": "cInBG4576", + "hwAddress": "%E457.6", + "comment": "in Separator (ILS-KR M2110)", + "role": "sensorInSep", + "unit": "M2110", + "cabinet": null, + "pos": null + }, + { + "id": "BG4577", + "constant": "cInBG4577", + "hwAddress": "%E457.7", + "comment": "Stausensor 3 (KR-M2110)", + "role": "sensorJam", + "unit": "M2110", + "cabinet": "UC0311", + "pos": [ + 243083.2, + 446432.8 + ] + }, + { + "id": "DI4610", + "constant": "cInDI4610", + "hwAddress": "%E461.0", + "comment": "IF BST \"No fire alarm\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 248625.8, + 452383.1 + ] + }, + { + "id": "DI4611", + "constant": "cInDI4611", + "hwAddress": "%E461.1", + "comment": "IF BST \"Non fault\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 248625.8, + 452113.1 + ] + }, + { + "id": "DI4612", + "constant": "cInDI4612", + "hwAddress": "%E461.2", + "comment": "IF BST \"FPC opened\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 248625.8, + 451843.1 + ] + }, + { + "id": "BG4621", + "constant": "cInBG4621", + "hwAddress": "%E462.1", + "comment": "Stausensor (ILS-CV M4102)", + "role": "sensorJam", + "unit": "M4102", + "cabinet": "U0312", + "pos": [ + 252428.0, + 448890.2 + ] + }, + { + "id": "BG4622", + "constant": "cInBG4622", + "hwAddress": "%E462.2", + "comment": "Sensor Förderer voll (ILS-CV M4102)", + "role": "sensorConvFull", + "unit": "M4102", + "cabinet": "U0312", + "pos": [ + 252960.1, + 449283.1 + ] + }, + { + "id": "BG4623", + "constant": "cInBG4623", + "hwAddress": "%E462.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4102)", + "role": "sensorFinger", + "unit": "M4102", + "cabinet": "U0312", + "pos": [ + 282646.2, + 448909.4 + ] + }, + { + "id": "BG4624", + "constant": "cInBG4624", + "hwAddress": "%E462.4", + "comment": "in Separator 1 (ILS-CV M4102)", + "role": "sensorInSep", + "unit": "M4102", + "cabinet": "U0312", + "pos": [ + 283386.0, + 448905.9 + ] + }, + { + "id": "BG4625", + "constant": "cInBG4625", + "hwAddress": "%E462.5", + "comment": "MT in Position (ILS-CV M4102)", + "role": "sensorCarrInPos", + "unit": "M4102", + "cabinet": "U0312", + "pos": [ + 281901.0, + 448905.9 + ] + }, + { + "id": "BG4631", + "constant": "cInBG4631", + "hwAddress": "%E463.1", + "comment": "Stausensor (ILS-CV M4202)", + "role": "sensorJam", + "unit": "M4202", + "cabinet": "U0312", + "pos": [ + 254566.9, + 448561.8 + ] + }, + { + "id": "BG4632", + "constant": "cInBG4632", + "hwAddress": "%E463.2", + "comment": "Sensor Förderer voll (ILS-CV M4202)", + "role": "sensorConvFull", + "unit": "M4202", + "cabinet": "U0312", + "pos": [ + 254569.6, + 448295.3 + ] + }, + { + "id": "BG4633", + "constant": "cInBG4633", + "hwAddress": "%E463.3", + "comment": "in Separator 1 (ILS-CV M4202)", + "role": "sensorInSep", + "unit": "M4202", + "cabinet": "UC0312", + "pos": [ + 283939.1, + 446445.0 + ] + }, + { + "id": "BG4634", + "constant": "cInBG4634", + "hwAddress": "%E463.4", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4202)", + "role": "sensorFinger", + "unit": "M4202", + "cabinet": "UC0312", + "pos": [ + 283199.3, + 446718.4 + ] + }, + { + "id": "BG4635", + "constant": "cInBG4635", + "hwAddress": "%E463.5", + "comment": "MT in Position (ILS-CV M4202)", + "role": "sensorCarrInPos", + "unit": "M4202", + "cabinet": "UC0312", + "pos": [ + 282381.6, + 446714.1 + ] + }, + { + "id": "BG4640", + "constant": "cInBG4640", + "hwAddress": "%E464.0", + "comment": "in Separator (ILS-CV M4301)", + "role": "sensorInSep", + "unit": "M4301", + "cabinet": "U0312", + "pos": [ + 253789.4, + 445954.5 + ] + }, + { + "id": "BG4641", + "constant": "cInBG4641", + "hwAddress": "%E464.1", + "comment": "MT in Position (ILS-CV M4301)", + "role": "sensorCarrInPos", + "unit": "M4301", + "cabinet": "U0312", + "pos": [ + 255274.4, + 446224.5 + ] + }, + { + "id": "BG4642", + "constant": "cInBG4642", + "hwAddress": "%E464.2", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4301)", + "role": "sensorFinger", + "unit": "M4301", + "cabinet": "U0312", + "pos": [ + 254539.8, + 446228.7 + ] + }, + { + "id": "BG4643", + "constant": "cInBG4643", + "hwAddress": "%E464.3", + "comment": "Stausensor (ILS-CV M4301)", + "role": "sensorJam", + "unit": "M4301", + "cabinet": "UC0312", + "pos": [ + 285422.4, + 448905.9 + ] + }, + { + "id": "BG4644", + "constant": "cInBG4644", + "hwAddress": "%E464.4", + "comment": "Sensor (ILS-CV M4301)", + "role": "sensorConvFull", + "unit": "M4301", + "cabinet": "UC0312", + "pos": [ + 284687.9, + 448910.1 + ] + }, + { + "id": "BG4646", + "constant": "cInBG4646", + "hwAddress": "%E464.6", + "comment": "Stausensor empty MT-line 75% voll", + "role": "sensorJam", + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG4647", + "constant": "cInBG4647", + "hwAddress": "%E464.7", + "comment": "Stausensor loaded MT-line 75% voll", + "role": "sensorJam", + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG4650", + "constant": "cInBG4650", + "hwAddress": "%E465.0", + "comment": "in Separator (ILS-CV M4401)", + "role": "sensorInSep", + "unit": "M4401", + "cabinet": "UC0312", + "pos": [ + 251887.7, + 445684.5 + ] + }, + { + "id": "BG4651", + "constant": "cInBG4651", + "hwAddress": "%E465.1", + "comment": "MT in Position (ILS-CV M4401)", + "role": "sensorCarrInPos", + "unit": "M4401", + "cabinet": "UC0312", + "pos": [ + 252998.3, + 445954.5 + ] + }, + { + "id": "BG4652", + "constant": "cInBG4652", + "hwAddress": "%E465.2", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4401)", + "role": "sensorFinger", + "unit": "M4401", + "cabinet": "UC0312", + "pos": [ + 252321.6, + 446227.9 + ] + }, + { + "id": "BG4653", + "constant": "cInBG4653", + "hwAddress": "%E465.3", + "comment": "Stausensor (ILS-CV M4401)", + "role": "sensorJam", + "unit": "M4401", + "cabinet": "UC0312", + "pos": [ + 286322.6, + 446987.0 + ] + }, + { + "id": "BG4654", + "constant": "cInBG4654", + "hwAddress": "%E465.4", + "comment": "Sensor Förderer voll (ILS-CV M4401)", + "role": "sensorConvFull", + "unit": "M4401", + "cabinet": "UC0312", + "pos": [ + 284839.4, + 446718.1 + ] + } + ], + "units": [ + { + "unit": "K2101", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.1.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.1.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC1101", + "pos": [ + 186658.6, + 459134.2 + ], + "io": { + "sensorPinQuery": [ + "BG3002", + "BG3010", + "BG3011", + "BG3012", + "BG3062", + "BG3067", + "BG3070", + "BG3071", + "BG3072" + ], + "sensorWheel": [ + "BG3007" + ], + "sensorJam": [ + "BG3065" + ] + }, + "signalCount": 11 + }, + { + "unit": "K2102", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.1.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.1.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC3103", + "pos": [ + 207628.8, + 459134.2 + ], + "io": { + "sensorPinQuery": [ + "BG3122", + "BG3127", + "BG3130", + "BG3131", + "BG3132", + "BG3133", + "BG3182", + "BG3187", + "BG3190", + "BG3191" + ], + "sensorJam": [ + "BG3185" + ] + }, + "signalCount": 11 + }, + { + "unit": "K2105", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC3101", + "pos": [ + 187126.0, + 456968.4 + ], + "io": { + "sensorJam": [ + "BG3005" + ] + }, + "signalCount": 1 + }, + { + "unit": "K2107", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC3103", + "pos": [ + 206612.7, + 457128.2 + ], + "io": { + "sensorJam": [ + "BG3125" + ] + }, + "signalCount": 1 + }, + { + "unit": "K2110", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC0309", + "pos": [ + 242270.9, + 457166.7 + ], + "io": { + "sensorJam": [ + "BG4443" + ], + "sensorInSep": [ + "BG4444" + ], + "stopperOutput": [ + "MB4444" + ] + }, + "signalCount": 3 + }, + { + "unit": "K2201", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.2.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.2.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0305", + "pos": [ + 186578.7, + 438134.2 + ], + "io": { + "sensorPinQuery": [ + "BG3482", + "BG3487", + "BG3490", + "BG3491", + "BG3542", + "BG3547", + "BG3550", + "BG3551", + "BG3552" + ] + }, + "signalCount": 9 + }, + { + "unit": "K2202", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.2.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.2.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0307", + "pos": [ + 207629.1, + 438128.1 + ], + "io": { + "sensorPinQuery": [ + "BG3602", + "BG3607", + "BG3610", + "BG3611", + "BG3612", + "BG3613", + "BG3670" + ] + }, + "signalCount": 7 + }, + { + "unit": "K2205", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0305", + "pos": [ + 187126.0, + 435968.4 + ], + "io": { + "sensorJam": [ + "BG3485" + ] + }, + "signalCount": 1 + }, + { + "unit": "K2206", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0306", + "pos": [ + 204362.7, + 435968.4 + ], + "io": { + "sensorJam": [ + "BG3545" + ] + }, + "signalCount": 1 + }, + { + "unit": "K2207", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0307", + "pos": [ + 206612.9, + 435852.1 + ], + "io": { + "sensorJam": [ + "BG3605" + ] + }, + "signalCount": 1 + }, + { + "unit": "K2208", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0308", + "pos": [ + 227613.0, + 435957.3 + ], + "io": { + "sensorJam": [ + "BG3665" + ] + }, + "signalCount": 1 + }, + { + "unit": "K2210", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep1Swi", + "areas": [ + { + "id": "Block 2.3.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0310", + "pos": [ + 242293.8, + 400551.2 + ], + "io": { + "sensorInSep": [ + "BG4395" + ], + "sensorWheel": [ + "BG4396" + ], + "sensorJam": [ + "BG4507" + ], + "switchOutput": [ + "MB4392" + ], + "stopperOutput": [ + "MB4395" + ] + }, + "signalCount": 5 + }, + { + "unit": "K2303", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.3.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.3.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC3301", + "pos": [ + 186307.2, + 399824.2 + ], + "io": { + "sensorPinQuery": [ + "BG4202", + "BG4207", + "BG4210", + "BG4211", + "BG4212", + "BG4262", + "BG4267", + "BG4270", + "BG4271", + "BG4272" + ], + "sensorJam": [ + "BG4273" + ] + }, + "signalCount": 11 + }, + { + "unit": "K2304", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.3.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.3.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC3303", + "pos": [ + 207454.4, + 399808.7 + ], + "io": { + "sensorPinQuery": [ + "BG4322", + "BG4327", + "BG4330", + "BG4331", + "BG4332", + "BG4333", + "BG4382", + "BG4387", + "BG4390", + "BG4391" + ], + "sensorJam": [ + "BG4375" + ] + }, + "signalCount": 11 + }, + { + "unit": "K2307", + "unitKind": "KR", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC3303", + "pos": [ + 206399.7, + 401002.7 + ], + "io": { + "sensorJam": [ + "BG4325" + ] + }, + "signalCount": 1 + }, + { + "unit": "M0201", + "unitKind": "KR", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": null, + "pos": [ + 252691.8, + 415520.7 + ], + "io": { + "motorProtection": [ + "FC0201" + ] + }, + "signalCount": 1 + }, + { + "unit": "M1209", + "unitKind": "CV", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0307", + "pos": [ + 226572.6, + 439215.3 + ], + "io": { + "sensorJam": [ + "BG3615" + ] + }, + "signalCount": 1 + }, + { + "unit": "M2101", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.1.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.1.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC3101", + "pos": [ + 252810.4, + 456484.7 + ], + "io": { + "motorProtection": [ + "FC0140" + ], + "sensorPinQuery": [ + "BG3001", + "BG3061" + ], + "sensorJam": [ + "BG3003", + "BG3063", + "BG3073" + ], + "motorOutput": [ + "MA0140" + ] + }, + "signalCount": 7 + }, + { + "unit": "M2102", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.1.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.1.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC3103", + "pos": [ + 252810.4, + 456214.7 + ], + "io": { + "motorProtection": [ + "FC0141" + ], + "sensorPinQuery": [ + "BG3121", + "BG3181" + ], + "sensorJam": [ + "BG3123", + "BG3136", + "BG3140", + "BG3183", + "BG3193", + "BG3194" + ], + "sensorInSep": [ + "BG3134", + "BG3192" + ], + "motorOutput": [ + "MA0141" + ], + "stopperOutput": [ + "MB3134", + "MB3192" + ] + }, + "signalCount": 14 + }, + { + "unit": "M2103", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [ + { + "id": "Block 2.1.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0301", + "pos": [ + 252775.2, + 429330.1 + ], + "io": { + "motorProtection": [ + "FC0060" + ], + "sensorJam": [ + "BG3242", + "BG3302", + "BG3305" + ], + "sensorInSep": [ + "BG3245", + "BG3300" + ], + "sensorWheel": [ + "BG3306" + ], + "motorOutput": [ + "MA0060" + ], + "stopperOutput": [ + "MB3245", + "MB3300" + ] + }, + "signalCount": 10 + }, + { + "unit": "M2104", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [ + { + "id": "Block 2.1.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0303", + "pos": [ + 252775.2, + 429060.1 + ], + "io": { + "motorProtection": [ + "FC0061" + ], + "sensorJam": [ + "BG3362", + "BG3365", + "BG3422" + ], + "sensorInSep": [ + "BG3425", + "BG3431" + ], + "sensorWheel": [ + "BG3436" + ], + "motorOutput": [ + "MA0061" + ], + "stopperOutput": [ + "MB3425", + "MB3431" + ] + }, + "signalCount": 10 + }, + { + "unit": "M2105", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0301", + "pos": [ + 252811.4, + 455942.5 + ], + "io": { + "motorProtection": [ + "FC0142" + ], + "sensorJam": [ + "BG3241" + ], + "sensorFinger": [ + "BG3243" + ], + "sensorInSep": [ + "BG3244" + ], + "sensorCarrInPos": [ + "BG3247" + ], + "motorOutput": [ + "MA0142" + ], + "switchOutput": [ + "MB3241" + ], + "stopperOutput": [ + "MB3244" + ] + }, + "signalCount": 8 + }, + { + "unit": "M2106", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0302", + "pos": [ + 254920.8, + 456484.7 + ], + "io": { + "motorProtection": [ + "FC0143" + ], + "sensorJam": [ + "BG3301" + ], + "sensorFinger": [ + "BG3303" + ], + "sensorInSep": [ + "BG3304" + ], + "sensorCarrInPos": [ + "BG3307" + ], + "motorOutput": [ + "MA0143" + ], + "stopperOutput": [ + "MB3304" + ] + }, + "signalCount": 7 + }, + { + "unit": "M2107", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0303", + "pos": [ + 254920.8, + 456204.7 + ], + "io": { + "motorProtection": [ + "FC0144" + ], + "sensorJam": [ + "BG3361" + ], + "sensorFinger": [ + "BG3363" + ], + "sensorInSep": [ + "BG3364" + ], + "sensorCarrInPos": [ + "BG3367" + ], + "motorOutput": [ + "MA0144" + ], + "stopperOutput": [ + "MB3364" + ] + }, + "signalCount": 7 + }, + { + "unit": "M2108", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0304", + "pos": [ + 254920.8, + 455944.7 + ], + "io": { + "motorProtection": [ + "FC0145" + ], + "sensorJam": [ + "BG3421" + ], + "sensorFinger": [ + "BG3423" + ], + "sensorInSep": [ + "BG3424" + ], + "sensorCarrInPos": [ + "BG3427" + ], + "motorOutput": [ + "MA0145" + ], + "switchOutput": [ + "MB3421" + ], + "stopperOutput": [ + "MB3424" + ] + }, + "signalCount": 8 + }, + { + "unit": "M2109", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "Block 2.1.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0304", + "pos": [ + 255200.1, + 429330.1 + ], + "io": { + "motorProtection": [ + "FC0070" + ], + "sensorInSep": [ + "BG3432", + "BG3440" + ], + "sensorJam": [ + "BG3435" + ], + "sensorCarrInPos": [ + "BG3441" + ], + "sensorFinger": [ + "BG3442" + ], + "motorOutput": [ + "MA0070" + ], + "stopperOutput": [ + "MB3432", + "MB3440" + ] + }, + "signalCount": 9 + }, + { + "unit": "M2110", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC0310", + "pos": [ + 255200.1, + 429060.1 + ], + "io": { + "motorProtection": [ + "FC0071" + ], + "sensorInSep": [ + "BG4500", + "BG4503", + "BG4560", + "BG4576" + ], + "sensorJam": [ + "BG4504", + "BG4577" + ], + "sensorWheel": [ + "BG4505" + ], + "motorOutput": [ + "MA0071" + ], + "stopperOutput": [ + "MB4500", + "MB4503", + "MB4560", + "MB4576" + ] + }, + "signalCount": 13 + }, + { + "unit": "M2111", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0309", + "pos": [ + 255200.1, + 428520.1 + ], + "io": { + "motorProtection": [ + "FC0073" + ], + "sensorInSep": [ + "BG4450" + ], + "sensorFinger": [ + "BG4451" + ], + "sensorCarrInPos": [ + "BG4452" + ], + "motorOutput": [ + "MA0073" + ], + "stopperOutput": [ + "MB4450" + ] + }, + "signalCount": 6 + }, + { + "unit": "M2112", + "unitKind": "KR", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": "UH03", + "pos": [ + 255200.1, + 428790.1 + ], + "io": { + "motorProtection": [ + "FC0072" + ], + "motorOutput": [ + "MA0072" + ] + }, + "signalCount": 2 + }, + { + "unit": "M2201", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.2.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.2.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0305", + "pos": [ + 252775.2, + 428790.1 + ], + "io": { + "motorProtection": [ + "FC0062" + ], + "sensorPinQuery": [ + "BG3481", + "BG3541" + ], + "sensorJam": [ + "BG3483", + "BG3543", + "BG3553" + ], + "motorOutput": [ + "MA0062" + ] + }, + "signalCount": 7 + }, + { + "unit": "M2202", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.2.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.2.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0307", + "pos": [ + 252775.2, + 428520.1 + ], + "io": { + "motorProtection": [ + "FC0063" + ], + "sensorPinQuery": [ + "BG3601", + "BG3661", + "BG3662", + "BG3667", + "BG3671" + ], + "sensorJam": [ + "BG3603", + "BG3616", + "BG3625", + "BG3663", + "BG3673", + "BG3674" + ], + "motorOutput": [ + "MA0063" + ] + }, + "signalCount": 13 + }, + { + "unit": "M2203", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC032", + "pos": [ + 252692.4, + 415790.7 + ], + "io": { + "motorProtection": [ + "FC0200" + ], + "sensorJam": [ + "BG3722", + "BG3782", + "BG3785" + ], + "sensorInSep": [ + "BG3725" + ], + "sensorWheel": [ + "BG3786" + ], + "motorOutput": [ + "MA0200" + ], + "stopperOutput": [ + "MB3725" + ] + }, + "signalCount": 8 + }, + { + "unit": "M2204", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC032", + "pos": [ + 207432.5, + 422541.4 + ], + "io": { + "sensorJam": [ + "BG3842", + "BG3845", + "BG3902", + "BG3906" + ], + "sensorInSep": [ + "BG3900" + ], + "sensorWheel": [ + "BG3916" + ], + "motorOutput": [ + "MA0201" + ], + "stopperOutput": [ + "MB3900" + ] + }, + "signalCount": 8 + }, + { + "unit": "M2205", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "Block 2.2.1", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0205", + "pos": [ + 252775.2, + 428250.1 + ], + "io": { + "motorProtection": [ + "FC0064" + ], + "sensorConvFull": [ + "BG3486" + ], + "sensorJam": [ + "BG3721" + ], + "sensorInSep": [ + "BG3724" + ], + "sensorCarrInPos": [ + "BG3727" + ], + "motorOutput": [ + "MA0064" + ], + "stopperOutput": [ + "MB3724" + ] + }, + "signalCount": 7 + }, + { + "unit": "M2206", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "Block 2.2.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC0206", + "pos": [ + 252775.2, + 427980.1 + ], + "io": { + "motorProtection": [ + "FC0065" + ], + "sensorConvFull": [ + "BG3546" + ], + "sensorJam": [ + "BG3781" + ], + "sensorFinger": [ + "BG3783", + "BG4023" + ], + "sensorInSep": [ + "BG3784", + "BG4024" + ], + "sensorCarrInPos": [ + "BG3787", + "BG4027" + ], + "motorOutput": [ + "MA0065" + ], + "switchOutput": [ + "MB3781" + ], + "stopperOutput": [ + "MB3784", + "MB4024" + ] + }, + "signalCount": 13 + }, + { + "unit": "M2207", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "Block 2.2.3", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC3203", + "pos": [ + 252775.2, + 427710.1 + ], + "io": { + "motorProtection": [ + "FC0066" + ], + "sensorJam": [ + "BG3841" + ], + "sensorFinger": [ + "BG3843" + ], + "sensorInSep": [ + "BG3844" + ], + "sensorCarrInPos": [ + "BG3847" + ], + "motorOutput": [ + "MA0066" + ], + "switchOutput": [ + "MB3841" + ], + "stopperOutput": [ + "MB3844" + ] + }, + "signalCount": 8 + }, + { + "unit": "M2208", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC3204", + "pos": [ + 252775.2, + 427440.1 + ], + "io": { + "motorProtection": [ + "FC0067" + ], + "sensorJam": [ + "BG3901" + ], + "sensorFinger": [ + "BG3903" + ], + "sensorInSep": [ + "BG3904" + ], + "sensorCarrInPos": [ + "BG3907" + ], + "motorOutput": [ + "MA0067" + ], + "switchOutput": [ + "MB3901" + ], + "stopperOutput": [ + "MB3904" + ] + }, + "signalCount": 8 + }, + { + "unit": "M2209", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "Block 2.1.4", + "kind": "pinStoreBlock" + }, + { + "id": "Block 1.2.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC032", + "pos": [ + 252691.8, + 414440.7 + ], + "io": { + "motorProtection": [ + "FC0205" + ], + "sensorInSep": [ + "BG3912", + "BG3920" + ], + "sensorJam": [ + "BG3915" + ], + "sensorCarrInPos": [ + "BG3921" + ], + "sensorFinger": [ + "BG3922" + ], + "motorOutput": [ + "MA0205" + ], + "stopperOutput": [ + "MB3912", + "MB3920" + ] + }, + "signalCount": 9 + }, + { + "unit": "M2301", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC032", + "pos": [ + 252691.8, + 415250.7 + ], + "io": { + "motorProtection": [ + "FC0202" + ], + "sensorJam": [ + "BG3962", + "BG4022", + "BG4025" + ], + "sensorInSep": [ + "BG3965" + ], + "sensorWheel": [ + "BG4026" + ], + "motorOutput": [ + "MA0202" + ], + "stopperOutput": [ + "MB3965" + ] + }, + "signalCount": 8 + }, + { + "unit": "M2302", + "unitKind": "KR", + "fbType": "FB_Conveyor", + "areas": [ + { + "id": "Block 2.3.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC032", + "pos": [ + 252691.8, + 414980.7 + ], + "io": { + "motorProtection": [ + "FC0203" + ], + "sensorJam": [ + "BG4082", + "BG4142", + "BG4152" + ], + "sensorWheel": [ + "BG4150" + ], + "motorOutput": [ + "MA0203" + ] + }, + "signalCount": 6 + }, + { + "unit": "M2303", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.3.1", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.3.2", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC033", + "pos": [ + 252692.4, + 398454.8 + ], + "io": { + "motorProtection": [ + "FC0260" + ], + "sensorPinQuery": [ + "BG4201", + "BG4261" + ], + "sensorJam": [ + "BG4203", + "BG4263" + ], + "motorOutput": [ + "MA0260" + ] + }, + "signalCount": 6 + }, + { + "unit": "M2304", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_PinStore_Auto", + "areas": [ + { + "id": "Block 2.3.3", + "kind": "pinStoreBlock" + }, + { + "id": "Block 2.3.4", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC033", + "pos": [ + 252692.4, + 398184.8 + ], + "io": { + "motorProtection": [ + "FC0261" + ], + "sensorPinQuery": [ + "BG4321", + "BG4381" + ], + "sensorJam": [ + "BG4323", + "BG4383" + ], + "motorOutput": [ + "MA0261" + ] + }, + "signalCount": 6 + }, + { + "unit": "M2305", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "Block 2.3.1", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC033", + "pos": [ + 252692.4, + 397907.9 + ], + "io": { + "motorProtection": [ + "FC0262" + ], + "sensorJam": [ + "BG3961" + ], + "sensorFinger": [ + "BG3963" + ], + "sensorInSep": [ + "BG3964" + ], + "sensorCarrInPos": [ + "BG3967", + "BG4087" + ], + "motorOutput": [ + "MA0262" + ], + "switchOutput": [ + "MB3961" + ], + "stopperOutput": [ + "MB3964" + ] + }, + "signalCount": 9 + }, + { + "unit": "M2306", + "unitKind": "CV", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": "UC033", + "pos": [ + 252692.4, + 397644.8 + ], + "io": { + "motorProtection": [ + "FC0263" + ], + "sensorJam": [ + "BG4021" + ], + "motorOutput": [ + "MA0263" + ] + }, + "signalCount": 3 + }, + { + "unit": "M2307", + "unitKind": "CV", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": null, + "pos": [ + 252692.4, + 397374.8 + ], + "io": { + "motorProtection": [ + "FC0264" + ] + }, + "signalCount": 1 + }, + { + "unit": "M2308", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "Block 2.3.3", + "kind": "pinStoreBlock" + } + ], + "cabinet": "UC033", + "pos": [ + 252692.4, + 397104.8 + ], + "io": { + "motorProtection": [ + "FC0265" + ], + "sensorJam": [ + "BG4081", + "BG4141", + "BG4385" + ], + "sensorInSep": [ + "BG4084", + "BG4144", + "BG4384" + ], + "sensorFinger": [ + "BG4143" + ], + "sensorCarrInPos": [ + "BG4147" + ], + "motorOutput": [ + "MA0265" + ], + "stopperOutput": [ + "MB4084", + "MB4144", + "MB4384" + ] + }, + "signalCount": 13 + }, + { + "unit": "M2309", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC032", + "pos": [ + 252691.8, + 414710.7 + ], + "io": { + "motorProtection": [ + "FC0204" + ], + "sensorInSep": [ + "BG4095" + ], + "sensorCarrInPos": [ + "BG4096" + ], + "sensorFinger": [ + "BG4097" + ], + "motorOutput": [ + "MA0204" + ], + "stopperOutput": [ + "MB4095" + ] + }, + "signalCount": 6 + }, + { + "unit": "M4101", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0311", + "pos": [ + 255201.7, + 428251.6 + ], + "io": { + "motorProtection": [ + "FC0074" + ], + "sensorInSep": [ + "BG4562", + "BG4566" + ], + "sensorJam": [ + "BG4564" + ], + "sensorConvFull": [ + "BG4565" + ], + "sensorFinger": [ + "BG4567" + ], + "sensorCarrInPos": [ + "BG4570" + ], + "motorOutput": [ + "MA0074" + ], + "stopperOutput": [ + "MB4562", + "MB4566" + ] + }, + "signalCount": 10 + }, + { + "unit": "M4102", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "U0312", + "pos": [ + 255200.1, + 427671.4 + ], + "io": { + "motorProtection": [ + "FC0090" + ], + "sensorJam": [ + "BG4621" + ], + "sensorConvFull": [ + "BG4622" + ], + "sensorFinger": [ + "BG4623" + ], + "sensorInSep": [ + "BG4624" + ], + "sensorCarrInPos": [ + "BG4625" + ], + "motorOutput": [ + "MA0090" + ], + "stopperOutput": [ + "MB4624" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4201", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0311", + "pos": [ + 255200.1, + 427980.1 + ], + "io": { + "motorProtection": [ + "FC0075" + ], + "sensorJam": [ + "BG4563" + ], + "sensorCarrInPos": [ + "BG4571" + ], + "sensorInSep": [ + "BG4572", + "BG4575" + ], + "sensorFinger": [ + "BG4573" + ], + "sensorConvFull": [ + "BG4574" + ], + "motorOutput": [ + "MA0075" + ], + "stopperOutput": [ + "MB4572", + "MB4575" + ] + }, + "signalCount": 10 + }, + { + "unit": "M4202", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "U0312", + "pos": [ + 255200.1, + 427401.4 + ], + "io": { + "motorProtection": [ + "FC0091" + ], + "sensorJam": [ + "BG4631" + ], + "sensorConvFull": [ + "BG4632" + ], + "sensorInSep": [ + "BG4633" + ], + "sensorFinger": [ + "BG4634" + ], + "sensorCarrInPos": [ + "BG4635" + ], + "motorOutput": [ + "MA0091" + ], + "stopperOutput": [ + "MB4633" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4301", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "U0312", + "pos": [ + 255208.1, + 427138.7 + ], + "io": { + "motorProtection": [ + "FC0092" + ], + "sensorInSep": [ + "BG4640" + ], + "sensorCarrInPos": [ + "BG4641" + ], + "sensorFinger": [ + "BG4642" + ], + "sensorJam": [ + "BG4643" + ], + "sensorConvFull": [ + "BG4644" + ], + "motorOutput": [ + "MA0092" + ], + "stopperOutput": [ + "MB4640" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4401", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "U0312", + "pos": [ + 255200.4, + 426860.3 + ], + "io": { + "motorProtection": [ + "FC0093" + ], + "sensorInSep": [ + "BG4650" + ], + "sensorCarrInPos": [ + "BG4651" + ], + "sensorFinger": [ + "BG4652" + ], + "sensorJam": [ + "BG4653" + ], + "sensorConvFull": [ + "BG4654" + ], + "motorOutput": [ + "MA0093" + ], + "stopperOutput": [ + "MB4650" + ] + }, + "signalCount": 8 + } + ], + "areas": [ + { + "id": "Block 1.2.1", + "kind": "pinStoreBlock", + "members": [], + "cabinets": [ + "UC3201" + ] + }, + { + "id": "Block 1.2.4", + "kind": "pinStoreBlock", + "members": [ + "M2209" + ], + "cabinets": [ + "UC3204" + ] + }, + { + "id": "Block 2.1.1", + "kind": "pinStoreBlock", + "members": [ + "K2101", + "M2101" + ], + "cabinets": [ + "UC0301", + "UC1101", + "UC3101" + ] + }, + { + "id": "Block 2.1.2", + "kind": "pinStoreBlock", + "members": [ + "K2101", + "M2101", + "M2103" + ], + "cabinets": [ + "UC0202", + "UC0302", + "UC3102" + ] + }, + { + "id": "Block 2.1.3", + "kind": "pinStoreBlock", + "members": [ + "K2102", + "M2102" + ], + "cabinets": [ + "UC0203", + "UC0303", + "UC3103" + ] + }, + { + "id": "Block 2.1.4", + "kind": "pinStoreBlock", + "members": [ + "K2102", + "M2102", + "M2104", + "M2109", + "M2209" + ], + "cabinets": [ + "UC0304", + "UC3104", + "UC3204" + ] + }, + { + "id": "Block 2.2.1", + "kind": "pinStoreBlock", + "members": [ + "K2201", + "M2201", + "M2205" + ], + "cabinets": [ + "UC0305", + "UC3201" + ] + }, + { + "id": "Block 2.2.2", + "kind": "pinStoreBlock", + "members": [ + "K2201", + "M2201", + "M2206" + ], + "cabinets": [ + "UC0306", + "UC3202" + ] + }, + { + "id": "Block 2.2.3", + "kind": "pinStoreBlock", + "members": [ + "K2202", + "M2202", + "M2207" + ], + "cabinets": [ + "UC0307", + "UC3203", + "UC3303" + ] + }, + { + "id": "Block 2.2.4", + "kind": "pinStoreBlock", + "members": [ + "K2202", + "M2202" + ], + "cabinets": [ + "UC0304", + "UC0308", + "UC3204" + ] + }, + { + "id": "Block 2.3.1", + "kind": "pinStoreBlock", + "members": [ + "K2303", + "M2303", + "M2305" + ], + "cabinets": [ + "UC3205", + "UC3301" + ] + }, + { + "id": "Block 2.3.2", + "kind": "pinStoreBlock", + "members": [ + "K2303", + "M2303" + ], + "cabinets": [ + "UC3206", + "UC3302" + ] + }, + { + "id": "Block 2.3.3", + "kind": "pinStoreBlock", + "members": [ + "K2304", + "M2304", + "M2308" + ], + "cabinets": [ + "UC3207", + "UC3303" + ] + }, + { + "id": "Block 2.3.4", + "kind": "pinStoreBlock", + "members": [ + "K2210", + "K2304", + "M2302", + "M2304" + ], + "cabinets": [ + "UC3208", + "UC3304" + ] + }, + { + "id": "UZ0301", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0302", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0303", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0304", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0305", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0306", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0307", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0308", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0309", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0310", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0311", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0312", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0330", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3101", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3102", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3103", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3104", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3201", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3202", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3203", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3204", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3205", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3206", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3207", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3208", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3301", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3302", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3303", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ3304", + "kind": "safetyZone", + "members": [], + "cabinets": [] + } + ], + "unassignedSignals": [ + "BG4561", + "BP0004", + "BP0107", + "BP0167", + "BP0227", + "DI0005", + "DI0006", + "DI0007", + "DI0010", + "DI0011", + "DI0012", + "DI0013", + "DI0014", + "DI0015", + "DI0016", + "DI0021", + "DI0022", + "DI0023", + "DI0024", + "DI0025", + "DI0026", + "DI0033", + "DI0034", + "DI0035", + "DI0036", + "DI0037", + "DI0100", + "DI0101", + "DI0102", + "DI0103", + "DI0106", + "DI0114", + "DI0160", + "DI0161", + "DI0162", + "DI0163", + "DI0164", + "DI0165", + "DI0166", + "DI0174", + "DI0220", + "DI0221", + "DI0222", + "DI0223", + "DI0226", + "DI0234", + "DI4610", + "DI4611", + "DI4612", + "MB3061", + "MB3306", + "MB3541", + "MB3786", + "MB4026", + "MB4261", + "PF0000", + "PF0001", + "PF0002", + "PF0003", + "PF0004", + "PF0005", + "PF0006", + "PF0030", + "PF0031", + "PF0032", + "PF0033", + "PF0100", + "PF0101", + "PF0102", + "PF0117", + "PF0160", + "PF0161", + "PF0162", + "PF0177", + "PF0220", + "PF0221", + "PF0222", + "PF0237", + "QA0610", + "QA0611", + "QA0612", + "QA0613", + "QA0660", + "QA0661", + "QA0662", + "QA0663", + "QA0920", + "QA0921", + "QA0922", + "QA0923", + "QA1230", + "QA1231", + "QA1232", + "QA1233", + "QA1540", + "QA1541", + "QA1542", + "QA1543", + "SF0000", + "SF0001", + "SF0002", + "SF0003", + "SF0117", + "SF0177", + "SF0237", + "SF0400", + "SF0404", + "SF0541", + "SF0542", + "SF0545", + "SF0546", + "SF0710", + "SF0714", + "SF0781", + "SF0785", + "SF1020", + "SF1024", + "SF1091", + "SF1095", + "SF1330", + "SF1334", + "SF1401", + "SF1405" + ], + "todo": [ + "topology[] aus connect-Daten uebernommen — TRO-IDs den Einheiten (units[]) noch zuordnen", + "Timings, Priority, Release, customCode manuell pflegen" + ], + "topology": { + "format": "hmf-connect-v1", + "tros": [ + { + "id": "TRO300", + "fbType": "Vario", + "comment": "TRO 300 (Vario)", + "entries": [ + { + "jamArea": "JA4102_1", + "dbRef": "\"DB_JamArea4102\".stJam4102_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA4101_1", + "dbRef": "\"DB_JamArea4101\".stJam4101_1", + "to": "TRO302", + "kind": "finger" + } + ] + }, + { + "id": "TRO301", + "fbType": "1Sep", + "comment": "TRO 301(1Sep)", + "entries": [ + { + "jamArea": "JA4102_2", + "dbRef": "\"DB_JamArea4102\".stJam4102_2", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA4101_1", + "dbRef": "\"DB_JamArea4101\".stJam4101_1", + "to": "TRO302", + "kind": "normal" + } + ] + }, + { + "id": "TRO302", + "fbType": "Vario", + "comment": "TRO 302 (Vario)", + "entries": [ + { + "jamArea": "JA4101_1", + "dbRef": "\"DB_JamArea4101\".stJam4101_1", + "from": "TRO300", + "kind": "finger" + }, + { + "jamArea": "JA4101_1", + "dbRef": "\"DB_JamArea4101\".stJam4101_1", + "from": "TRO301", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4101_2", + "dbRef": "\"DB_JamArea4101\".stJam4101_2", + "to": "TRO311", + "kind": "finger" + } + ] + }, + { + "id": "TRO303", + "fbType": "Vario", + "comment": "TRO 303 (Vario)", + "entries": [ + { + "jamArea": "JA4202_1", + "dbRef": "\"DB_JamArea4202\".stJam4202_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA4201_1", + "dbRef": "\"DB_JamArea4201\".stJam4201_1", + "to": "TRO305", + "kind": "finger" + } + ] + }, + { + "id": "TRO304", + "fbType": "1Sep", + "comment": "TRO 304(1Sep)", + "entries": [ + { + "jamArea": "JA4202_2", + "dbRef": "\"DB_JamArea4202\".stJam4202_2", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA4201_1", + "dbRef": "\"DB_JamArea4201\".stJam4201_1", + "to": "TRO305", + "kind": "normal" + } + ] + }, + { + "id": "TRO305", + "fbType": "Vario", + "comment": "TRO 305 (Vario)", + "entries": [ + { + "jamArea": "JA4201_1", + "dbRef": "\"DB_JamArea4201\".stJam4201_1", + "from": "TRO303", + "kind": "finger" + }, + { + "jamArea": "JA4201_1", + "dbRef": "\"DB_JamArea4201\".stJam4201_1", + "from": "TRO304", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4201_2", + "dbRef": "\"DB_JamArea4201\".stJam4201_2", + "to": "TRO312", + "kind": "finger" + } + ] + }, + { + "id": "TRO306", + "fbType": "Vario", + "comment": "TRO 306 (Vario)", + "entries": [ + { + "jamArea": "JA4301_1", + "dbRef": "\"DB_JamArea4301\".stJam4301_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [] + }, + { + "id": "TRO307", + "fbType": "Vario", + "comment": "TRO 307 (Vario)", + "entries": [ + { + "jamArea": "JA4401_1", + "dbRef": "\"DB_JamArea4401\".stJam4401_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [] + }, + { + "id": "TRO308", + "fbType": "Vario", + "comment": "TRO 308 (Vario)", + "entries": [ + { + "jamArea": "JA2111_1", + "dbRef": "\"DB_JamArea2111\".stJam2111_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2111_2", + "dbRef": "\"DB_JamArea2111\".stJam2111_2", + "to": "TRO309", + "kind": "finger" + } + ] + }, + { + "id": "TRO309", + "fbType": "1Sep", + "comment": "TRO 309 (1Sep)", + "entries": [ + { + "jamArea": "JA2111_2", + "dbRef": "\"DB_JamArea2111\".stJam2111_2", + "from": "TRO308", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2110_5", + "dbRef": "\"DB_JamArea2110\".stJam2110_5", + "to": "TRO386", + "kind": "normal" + } + ] + }, + { + "id": "TRO310", + "fbType": "1Sep", + "comment": "TRO 310 (1Sep)+Scanner (BX3102)", + "entries": [ + { + "jamArea": "JA2110_1", + "dbRef": "\"DB_JamArea2110\".stJam2110_1", + "from": "TRO386", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2110_2", + "dbRef": "\"DB_JamArea2110\".stJam2110_2", + "to": "TRO313", + "kind": "normal" + } + ] + }, + { + "id": "TRO311", + "fbType": "1Sep", + "comment": "TRO 311 (1Sep)+Scanner(BX3101)", + "entries": [ + { + "jamArea": "JA4101_2", + "dbRef": "\"DB_JamArea4101\".stJam4101_2", + "from": "TRO302", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2110_2", + "dbRef": "\"DB_JamArea2110\".stJam2110_2", + "to": "TRO313", + "kind": "normal" + } + ] + }, + { + "id": "TRO312", + "fbType": "1Sep", + "comment": "TRO 312 (1Sep)+Scanner(BX3100)", + "entries": [ + { + "jamArea": "JA4201_2", + "dbRef": "\"DB_JamArea4201\".stJam4201_2", + "from": "TRO305", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2110_2", + "dbRef": "\"DB_JamArea2110\".stJam2110_2", + "to": "TRO313", + "kind": "normal" + } + ] + }, + { + "id": "TRO313", + "fbType": "1Sep1Swi", + "comment": "TRO 313 (1Sep1Switch)+Scanner(BX3103)", + "entries": [ + { + "jamArea": "JA2110_2", + "dbRef": "\"DB_JamArea2110\".stJam2110_2", + "from": "TRO310", + "kind": "normal" + }, + { + "jamArea": "JA2110_2", + "dbRef": "\"DB_JamArea2110\".stJam2110_2", + "from": "TRO311", + "kind": "normal" + }, + { + "jamArea": "JA2110_2", + "dbRef": "\"DB_JamArea2110\".stJam2110_2", + "from": "TRO312", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2110_3", + "dbRef": "\"DB_JamArea2110\".stJam2110_3", + "to": "TRO314", + "kind": "dir2" + }, + { + "jamArea": "JA2112_1", + "dbRef": "\"DB_JamArea2112\".stJam2112_1", + "to": "TRO316", + "kind": "normal" + } + ] + }, + { + "id": "TRO314", + "fbType": "1Sep1Swi", + "comment": "TRO 314 (1Sep1Switch)+Scanner(BX3104)", + "entries": [ + { + "jamArea": "JA2110_3", + "dbRef": "\"DB_JamArea2110\".stJam2110_3", + "from": "TRO313", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2110_4", + "dbRef": "\"DB_JamArea2110\".stJam2110_4", + "to": "TRO315", + "kind": "dir2" + }, + { + "jamArea": "JA2202_1", + "dbRef": "\"DB_JamArea2202\".stJam2202_1", + "to": "TRO339", + "kind": "normal" + } + ] + }, + { + "id": "TRO315", + "fbType": "1Sep", + "comment": "TRO 315 (1Sep)", + "entries": [ + { + "jamArea": "JA2110_4", + "dbRef": "\"DB_JamArea2110\".stJam2110_4", + "from": "TRO314", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2102_1", + "dbRef": "\"DB_JamArea2102\".stJam2102_1", + "to": "TRO317", + "kind": "normal" + } + ] + }, + { + "id": "TRO316", + "fbType": "1Sep", + "comment": "TRO 316 (1Sep)", + "entries": [ + { + "jamArea": "JA2112_1", + "dbRef": "\"DB_JamArea2112\".stJam2112_1", + "from": "TRO313", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2304_1", + "dbRef": "\"DB_JamArea2304\".stJam2304_1", + "to": "TRO361", + "kind": "normal" + } + ] + }, + { + "id": "TRO317", + "fbType": "1Sep1Swi", + "comment": "TRO 317 (1Sep1Switch)+Scanner(BX3105)", + "entries": [ + { + "jamArea": "JA2102_1", + "dbRef": "\"DB_JamArea2102\".stJam2102_1", + "from": "TRO315", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2102_2", + "dbRef": "\"DB_JamArea2102\".stJam2102_2", + "to": "TRO318", + "kind": "normal" + }, + { + "jamArea": "IO_Device_UH03_TO_UH01.stCarrierL2toL1", + "dbRef": "IO_Device_UH03_TO_UH01.stCarrierL2toL1", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO318", + "fbType": "1Sep1Swi", + "comment": "TRO 318 (1Sep1Switch) + Scanner(BX3106)", + "entries": [ + { + "jamArea": "JA2102_2", + "dbRef": "\"DB_JamArea2102\".stJam2102_2", + "from": "TRO317", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2101_1", + "dbRef": "\"DB_JamArea2101\".stJam2101_1", + "to": "TRO330", + "kind": "dir2" + }, + { + "jamArea": "JA2102_3", + "dbRef": "\"DB_JamArea2102\".stJam2102_3", + "to": "TRO333", + "kind": "normal" + } + ] + }, + { + "id": "TRO319", + "fbType": "1Sep1Swi", + "comment": "TRO 319 (1Sep1Switch) + Scanner (BX3111)", + "entries": [ + { + "jamArea": "JA2103_1", + "dbRef": "\"DB_JamArea2103\".stJam2103_1", + "from": "TRO327", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2103_2", + "dbRef": "\"DB_JamArea2103\".stJam2103_2", + "to": "TRO320", + "kind": "dir2" + }, + { + "jamArea": "JA2105_1", + "dbRef": "\"DB_JamArea2105\".stJam2105_1", + "to": "TRO328", + "kind": "normal" + } + ] + }, + { + "id": "TRO320", + "fbType": "1Sep1Swi", + "comment": "TRO 320 (1Sep1Switch) + Scanner(BX3112)", + "entries": [ + { + "jamArea": "JA2103_2", + "dbRef": "\"DB_JamArea2103\".stJam2103_2", + "from": "TRO330", + "kind": "normal" + }, + { + "jamArea": "JA2103_2", + "dbRef": "\"DB_JamArea2103\".stJam2103_2", + "from": "TRO319", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2104_3", + "dbRef": "\"DB_JamArea2104\".stJam2104_3", + "to": "TRO323", + "kind": "dir2" + }, + { + "jamArea": "JA2106_1", + "dbRef": "\"DB_JamArea2106\".stJam2106_1", + "to": "TRO331", + "kind": "normal" + } + ] + }, + { + "id": "TRO321", + "fbType": "1Sep1Swi", + "comment": "TRO 321 (1Sep1Switch) + Scanner(BX3114)", + "entries": [ + { + "jamArea": "JA2104_1", + "dbRef": "\"DB_JamArea2104\".stJam2104_1", + "from": "TRO336", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2104_2", + "dbRef": "\"DB_JamArea2104\".stJam2104_2", + "to": "TRO322", + "kind": "normal" + }, + { + "jamArea": "JA2108_1", + "dbRef": "\"DB_JamArea2108\".stJam2108_1", + "to": "TRO337", + "kind": "dir2" + } + ] + }, + { + "id": "TRO322", + "fbType": "1Sep1Swi", + "comment": "TRO 322 (1Sep1Switch)+Scanner(BX3113)", + "entries": [ + { + "jamArea": "JA2104_2", + "dbRef": "\"DB_JamArea2104\".stJam2104_2", + "from": "TRO333", + "kind": "normal" + }, + { + "jamArea": "JA2104_2", + "dbRef": "\"DB_JamArea2104\".stJam2104_2", + "from": "TRO321", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2104_3", + "dbRef": "\"DB_JamArea2104\".stJam2104_3", + "to": "TRO323", + "kind": "normal" + }, + { + "jamArea": "JA2107_1", + "dbRef": "\"DB_JamArea2107\".stJam2107_1", + "to": "TRO334", + "kind": "dir2" + } + ] + }, + { + "id": "TRO323", + "fbType": "1Sep", + "comment": "TRO 323 (1Sep)", + "entries": [ + { + "jamArea": "JA2104_3", + "dbRef": "\"DB_JamArea2104\".stJam2104_3", + "from": "TRO320", + "kind": "dir2" + }, + { + "jamArea": "JA2104_3", + "dbRef": "\"DB_JamArea2104\".stJam2104_3", + "from": "TRO322", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2104_4", + "dbRef": "\"DB_JamArea2104\".stJam2104_4", + "to": "TRO326", + "kind": "normal" + } + ] + }, + { + "id": "TRO324", + "fbType": "Vario", + "comment": "TRO 324 (Vario)", + "entries": [ + { + "jamArea": "JA2109_1", + "dbRef": "\"DB_JamArea2109\".stJam2109_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2109_2", + "dbRef": "\"DB_JamArea2109\".stJam2109_2", + "to": "TRO325", + "kind": "finger" + } + ] + }, + { + "id": "TRO325", + "fbType": "1Sep", + "comment": "TRO 325 (1Sep)", + "entries": [ + { + "jamArea": "JA2109_2", + "dbRef": "\"DB_JamArea2109\".stJam2109_2", + "from": "TRO324", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2104_4", + "dbRef": "\"DB_JamArea2104\".stJam2104_4", + "to": "TRO326", + "kind": "normal" + } + ] + }, + { + "id": "TRO326", + "fbType": "1Sep", + "comment": "TRO 326 (1Sep)", + "entries": [ + { + "jamArea": "JA2104_4", + "dbRef": "\"DB_JamArea2104\".stJam2104_4", + "from": "TRO323", + "kind": "normal" + }, + { + "jamArea": "JA2104_4", + "dbRef": "\"DB_JamArea2104\".stJam2104_4", + "from": "TRO325", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "IO_Device_UH03_TO_UH01.stCARRIER_INFO", + "dbRef": "IO_Device_UH03_TO_UH01.stCARRIER_INFO", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO327", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO327", + "entries": [ + { + "jamArea": "JA2101_2", + "dbRef": "\"DB_JamArea2101\".stJam2101_2", + "from": "TRO330", + "kind": "bypass" + }, + { + "jamArea": "JA2101_2", + "dbRef": "\"DB_JamArea2101\".stJam2101_2", + "from": "TRO329", + "kind": "normal" + }, + { + "jamArea": "Storage2.1.1", + "dbRef": "Storage2.1.1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2103_1", + "dbRef": "\"DB_JamArea2103\".stJam2103_1", + "to": "TRO319", + "kind": "normal" + } + ] + }, + { + "id": "TRO328", + "fbType": "Vario", + "comment": "TRO 328 (Vario)", + "entries": [ + { + "jamArea": "JA2105_1", + "dbRef": "\"DB_JamArea2105\".stJam2105_1", + "from": "TRO319", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2105_2", + "dbRef": "\"DB_JamArea2105\".stJam2105_2", + "to": "TRO329", + "kind": "finger" + } + ] + }, + { + "id": "TRO329", + "fbType": "1Sep", + "comment": "TRO 329 (1Sep)", + "entries": [ + { + "jamArea": "JA2105_2", + "dbRef": "\"DB_JamArea2105\".stJam2105_2", + "from": "TRO328", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2101_2", + "dbRef": "\"DB_JamArea2101\".stJam2101_2", + "to": "TRO327", + "kind": "normal" + } + ] + }, + { + "id": "TRO330", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO330", + "entries": [ + { + "jamArea": "JA2101_1", + "dbRef": "\"DB_JamArea2101\".stJam2101_1", + "from": "TRO318", + "kind": "dir2" + }, + { + "jamArea": "JA2101_1", + "dbRef": "\"DB_JamArea2101\".stJam2101_1", + "from": "TRO332", + "kind": "normal" + }, + { + "jamArea": "Storage2.1.2", + "dbRef": "Storage2.1.2", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2101_2", + "dbRef": "\"DB_JamArea2101\".stJam2101_2", + "to": "TRO327", + "kind": "bypass" + }, + { + "jamArea": "JA2103_2", + "dbRef": "\"DB_JamArea2103\".stJam2103_2", + "to": "TRO320", + "kind": "normal" + } + ] + }, + { + "id": "TRO331", + "fbType": "Vario", + "comment": "TRO 331 (Vario)", + "entries": [ + { + "jamArea": "JA2106_1", + "dbRef": "\"DB_JamArea2106\".stJam2106_1", + "from": "TRO320", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2106_2", + "dbRef": "\"DB_JamArea2106\".stJam2106_2", + "to": "TRO332", + "kind": "finger" + } + ] + }, + { + "id": "TRO332", + "fbType": "1Sep", + "comment": "TRO 332 (1Sep)", + "entries": [ + { + "jamArea": "JA2106_2", + "dbRef": "\"DB_JamArea2106\".stJam2106_2", + "from": "TRO331", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2101_1", + "dbRef": "\"DB_JamArea2101\".stJam2101_1", + "to": "TRO330", + "kind": "normal" + } + ] + }, + { + "id": "TRO333", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO333", + "entries": [ + { + "jamArea": "JA2102_3", + "dbRef": "\"DB_JamArea2102\".stJam2102_3", + "from": "TRO318", + "kind": "normal" + }, + { + "jamArea": "JA2102_3", + "dbRef": "\"DB_JamArea2102\".stJam2102_3", + "from": "TRO335", + "kind": "normal" + }, + { + "jamArea": "Storage2.1.3", + "dbRef": "Storage2.1.3", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2102_4", + "dbRef": "\"DB_JamArea2102\".stJam2102_4", + "to": "TRO336", + "kind": "bypass" + }, + { + "jamArea": "JA2104_2", + "dbRef": "\"DB_JamArea2104\".stJam2104_2", + "to": "TRO322", + "kind": "normal" + } + ] + }, + { + "id": "TRO334", + "fbType": "Vario", + "comment": "TRO 334 (Vario)", + "entries": [ + { + "jamArea": "JA2107_1", + "dbRef": "\"DB_JamArea2107\".stJam2107_1", + "from": "TRO322", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2107_2", + "dbRef": "\"DB_JamArea2107\".stJam2107_2", + "to": "TRO335", + "kind": "finger" + } + ] + }, + { + "id": "TRO335", + "fbType": "1Sep", + "comment": "TRO 335 (1Sep)", + "entries": [ + { + "jamArea": "JA2107_2", + "dbRef": "\"DB_JamArea2107\".stJam2107_2", + "from": "TRO334", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2102_3", + "dbRef": "\"DB_JamArea2102\".stJam2102_3", + "to": "TRO333", + "kind": "normal" + } + ] + }, + { + "id": "TRO336", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO336", + "entries": [ + { + "jamArea": "JA2102_4", + "dbRef": "\"DB_JamArea2102\".stJam2102_4", + "from": "TRO333", + "kind": "bypass" + }, + { + "jamArea": "JA2102_4", + "dbRef": "\"DB_JamArea2102\".stJam2102_4", + "from": "TRO338", + "kind": "normal" + }, + { + "jamArea": "Storage2.1.4", + "dbRef": "Storage2.1.4", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2104_1", + "dbRef": "\"DB_JamArea2104\".stJam2104_1", + "to": "TRO321", + "kind": "normal" + }, + { + "jamArea": "JA2102_5", + "dbRef": "\"DB_JamArea2102\".stJam2102_5", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO337", + "fbType": "Vario", + "comment": "TRO 337 (Vario)", + "entries": [ + { + "jamArea": "JA2108_1", + "dbRef": "\"DB_JamArea2108\".stJam2108_1", + "from": "TRO321", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2108_2", + "dbRef": "\"DB_JamArea2108\".stJam2108_2", + "to": "TRO338", + "kind": "finger" + } + ] + }, + { + "id": "TRO338", + "fbType": "1Sep", + "comment": "TRO 338 (1Sep)", + "entries": [ + { + "jamArea": "JA2108_2", + "dbRef": "\"DB_JamArea2108\".stJam2108_2", + "from": "TRO337", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2102_4", + "dbRef": "\"DB_JamArea2102\".stJam2102_4", + "to": "TRO336", + "kind": "normal" + } + ] + }, + { + "id": "TRO339", + "fbType": "1Sep1Swi", + "comment": "TRO 339 (1Sep1Switch)+Scanner(BX3120)", + "entries": [ + { + "jamArea": "JA2202_1", + "dbRef": "\"DB_JamArea2202\".stJam2202_1", + "from": "TRO314", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2202_2", + "dbRef": "\"DB_JamArea2202\".stJam2202_2", + "to": "TRO340", + "kind": "normal" + }, + { + "jamArea": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_2", + "dbRef": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_2", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO340", + "fbType": "1Sep1Swi", + "comment": "TRO 340 (1Sep1Switch)+Scanner(BX3121)", + "entries": [ + { + "jamArea": "JA2202_2", + "dbRef": "\"DB_JamArea2202\".stJam2202_2", + "from": "TRO339", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2201_1", + "dbRef": "\"DB_JamArea2201\".stJam2201_1", + "to": "TRO352", + "kind": "dir2" + }, + { + "jamArea": "JA2202_3", + "dbRef": "\"DB_JamArea2202\".stJam2202_3", + "to": "TRO355", + "kind": "normal" + } + ] + }, + { + "id": "TRO341", + "fbType": "1Sep1Swi", + "comment": "TRO 341 (1Sep1Switch)+Scanner(BX3126)", + "entries": [ + { + "jamArea": "JA2203_1", + "dbRef": "\"DB_JamArea2203\".stJam2203_1", + "from": "TRO349", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2203_2", + "dbRef": "\"DB_JamArea2203\".stJam2203_2", + "to": "TRO342", + "kind": "dir2" + }, + { + "jamArea": "JA2205_1", + "dbRef": "\"DB_JamArea2205\".stJam2205_1", + "to": "TRO350", + "kind": "normal" + } + ] + }, + { + "id": "TRO342", + "fbType": "1Sep1Swi", + "comment": "TRO 342 (1Sep1Switch)+Scanner(BX3127)", + "entries": [ + { + "jamArea": "JA2203_2", + "dbRef": "\"DB_JamArea2203\".stJam2203_2", + "from": "TRO352", + "kind": "normal" + }, + { + "jamArea": "JA2203_2", + "dbRef": "\"DB_JamArea2203\".stJam2203_2", + "from": "TRO341", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2204_3", + "dbRef": "\"DB_JamArea2204\".stJam2204_3", + "to": "TRO345", + "kind": "dir2" + }, + { + "jamArea": "JA2206_1", + "dbRef": "\"DB_JamArea2206\".stJam2206_1", + "to": "TRO353", + "kind": "normal" + } + ] + }, + { + "id": "TRO343", + "fbType": "1Sep1Swi", + "comment": "TRO 343 (1Sep1Switch)+Scanner(BX3129)", + "entries": [ + { + "jamArea": "JA2204_1", + "dbRef": "\"DB_JamArea2204\".stJam2204_1", + "from": "TRO358", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2204_2", + "dbRef": "\"DB_JamArea2204\".stJam2204_2", + "to": "TRO344", + "kind": "normal" + }, + { + "jamArea": "JA2208_1", + "dbRef": "\"DB_JamArea2208\".stJam2208_1", + "to": "TRO359", + "kind": "dir2" + } + ] + }, + { + "id": "TRO344", + "fbType": "1Sep1Swi", + "comment": "TRO 344 (1Sep1Switch)+Scanner(BX3128)", + "entries": [ + { + "jamArea": "JA2204_2", + "dbRef": "\"DB_JamArea2204\".stJam2204_2", + "from": "TRO355", + "kind": "normal" + }, + { + "jamArea": "JA2204_2", + "dbRef": "\"DB_JamArea2204\".stJam2204_2", + "from": "TRO343", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2204_3", + "dbRef": "\"DB_JamArea2204\".stJam2204_3", + "to": "TRO345", + "kind": "normal" + }, + { + "jamArea": "JA2207_1", + "dbRef": "\"DB_JamArea2207\".stJam2207_1", + "to": "TRO356", + "kind": "dir2" + } + ] + }, + { + "id": "TRO345", + "fbType": "1Sep", + "comment": "TRO 345 (1Sep)", + "entries": [ + { + "jamArea": "JA2204_3", + "dbRef": "\"DB_JamArea2204\".stJam2204_3", + "from": "TRO342", + "kind": "dir2" + }, + { + "jamArea": "JA2204_3", + "dbRef": "\"DB_JamArea2204\".stJam2204_3", + "from": "TRO344", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2204_4", + "dbRef": "\"DB_JamArea2204\".stJam2204_4", + "to": "TRO348", + "kind": "normal" + } + ] + }, + { + "id": "TRO346", + "fbType": "Vario", + "comment": "TRO 346 (Vario)", + "entries": [ + { + "jamArea": "JA2209_1", + "dbRef": "\"DB_JamArea2209\".stJam2209_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2209_2", + "dbRef": "\"DB_JamArea2209\".stJam2209_2", + "to": "TRO347", + "kind": "finger" + } + ] + }, + { + "id": "TRO347", + "fbType": "1Sep", + "comment": "TRO 347 (1Sep)", + "entries": [ + { + "jamArea": "JA2209_2", + "dbRef": "\"DB_JamArea2209\".stJam2209_2", + "from": "TRO346", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2204_4", + "dbRef": "\"DB_JamArea2204\".stJam2204_4", + "to": "TRO348", + "kind": "normal" + } + ] + }, + { + "id": "TRO348", + "fbType": "1Sep", + "comment": "TRO 348 (1Sep)", + "entries": [ + { + "jamArea": "JA2204_4", + "dbRef": "\"DB_JamArea2204\".stJam2204_4", + "from": "TRO345", + "kind": "normal" + }, + { + "jamArea": "JA2204_4", + "dbRef": "\"DB_JamArea2204\".stJam2204_4", + "from": "TRO347", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_1", + "dbRef": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_1", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO349", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO349", + "entries": [ + { + "jamArea": "JA2201_2", + "dbRef": "\"DB_JamArea2201\".stJam2201_2", + "from": "TRO352", + "kind": "bypass" + }, + { + "jamArea": "JA2201_2", + "dbRef": "\"DB_JamArea2201\".stJam2201_2", + "from": "TRO351", + "kind": "normal" + }, + { + "jamArea": "Storage2.2.1", + "dbRef": "Storage2.2.1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2203_1", + "dbRef": "\"DB_JamArea2203\".stJam2203_1", + "to": "TRO341", + "kind": "normal" + } + ] + }, + { + "id": "TRO350", + "fbType": "Vario", + "comment": "TRO 350 (Vario)", + "entries": [ + { + "jamArea": "JA2205_1", + "dbRef": "\"DB_JamArea2205\".stJam2205_1", + "from": "TRO341", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2205_2", + "dbRef": "\"DB_JamArea2205\".stJam2205_2", + "to": "TRO351", + "kind": "finger" + } + ] + }, + { + "id": "TRO351", + "fbType": "1Sep", + "comment": "TRO 351 (1Sep)", + "entries": [ + { + "jamArea": "JA2205_2", + "dbRef": "\"DB_JamArea2205\".stJam2205_2", + "from": "TRO350", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2201_2", + "dbRef": "\"DB_JamArea2201\".stJam2201_2", + "to": "TRO349", + "kind": "normal" + } + ] + }, + { + "id": "TRO352", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO352", + "entries": [ + { + "jamArea": "JA2201_1", + "dbRef": "\"DB_JamArea2201\".stJam2201_1", + "from": "TRO340", + "kind": "dir2" + }, + { + "jamArea": "JA2201_1", + "dbRef": "\"DB_JamArea2201\".stJam2201_1", + "from": "TRO354", + "kind": "normal" + }, + { + "jamArea": "Storage2.2.2", + "dbRef": "Storage2.2.2", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2201_2", + "dbRef": "\"DB_JamArea2201\".stJam2201_2", + "to": "TRO349", + "kind": "bypass" + }, + { + "jamArea": "JA2203_2", + "dbRef": "\"DB_JamArea2203\".stJam2203_2", + "to": "TRO342", + "kind": "normal" + } + ] + }, + { + "id": "TRO353", + "fbType": "Vario", + "comment": "TRO 353 (Vario)", + "entries": [ + { + "jamArea": "JA2206_1", + "dbRef": "\"DB_JamArea2206\".stJam2206_1", + "from": "TRO342", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2206_2", + "dbRef": "\"DB_JamArea2206\".stJam2206_2", + "to": "TRO354", + "kind": "finger" + } + ] + }, + { + "id": "TRO354", + "fbType": "1Sep", + "comment": "TRO 354 (1Sep)", + "entries": [ + { + "jamArea": "JA2206_2", + "dbRef": "\"DB_JamArea2206\".stJam2206_2", + "from": "TRO353", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2201_1", + "dbRef": "\"DB_JamArea2201\".stJam2201_1", + "to": "TRO352", + "kind": "normal" + } + ] + }, + { + "id": "TRO355", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO355", + "entries": [ + { + "jamArea": "JA2202_3", + "dbRef": "\"DB_JamArea2202\".stJam2202_3", + "from": "TRO340", + "kind": "normal" + }, + { + "jamArea": "JA2202_3", + "dbRef": "\"DB_JamArea2202\".stJam2202_3", + "from": "TRO357", + "kind": "normal" + }, + { + "jamArea": "Storage2.2.3", + "dbRef": "Storage2.2.3", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2202_4", + "dbRef": "\"DB_JamArea2202\".stJam2202_4", + "to": "TRO358", + "kind": "bypass" + }, + { + "jamArea": "JA2204_2", + "dbRef": "\"DB_JamArea2204\".stJam2204_2", + "to": "TRO344", + "kind": "normal" + } + ] + }, + { + "id": "TRO356", + "fbType": "Vario", + "comment": "TRO 356 (Vario)", + "entries": [ + { + "jamArea": "JA2207_1", + "dbRef": "\"DB_JamArea2207\".stJam2207_1", + "from": "TRO344", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2207_2", + "dbRef": "\"DB_JamArea2207\".stJam2207_2", + "to": "TRO357", + "kind": "finger" + } + ] + }, + { + "id": "TRO357", + "fbType": "1Sep", + "comment": "TRO 357 (1Sep)", + "entries": [ + { + "jamArea": "JA2207_2", + "dbRef": "\"DB_JamArea2207\".stJam2207_2", + "from": "TRO356", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2202_3", + "dbRef": "\"DB_JamArea2202\".stJam2202_3", + "to": "TRO355", + "kind": "normal" + } + ] + }, + { + "id": "TRO358", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO358", + "entries": [ + { + "jamArea": "JA2202_4", + "dbRef": "\"DB_JamArea2202\".stJam2202_4", + "from": "TRO355", + "kind": "bypass" + }, + { + "jamArea": "JA2202_4", + "dbRef": "\"DB_JamArea2202\".stJam2202_4", + "from": "TRO360", + "kind": "normal" + }, + { + "jamArea": "Storage2.2.4", + "dbRef": "Storage2.2.4", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2204_1", + "dbRef": "\"DB_JamArea2204\".stJam2204_1", + "to": "TRO343", + "kind": "normal" + }, + { + "jamArea": "JA2202_5", + "dbRef": "\"DB_JamArea2202\".stJam2202_5", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO359", + "fbType": "Vario", + "comment": "TRO 359 (Vario)", + "entries": [ + { + "jamArea": "JA2208_1", + "dbRef": "\"DB_JamArea2208\".stJam2208_1", + "from": "TRO343", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2208_2", + "dbRef": "\"DB_JamArea2208\".stJam2208_2", + "to": "TRO360", + "kind": "finger" + } + ] + }, + { + "id": "TRO360", + "fbType": "1Sep", + "comment": "TRO 360 (1Sep)", + "entries": [ + { + "jamArea": "JA2208_2", + "dbRef": "\"DB_JamArea2208\".stJam2208_2", + "from": "TRO359", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2202_4", + "dbRef": "\"DB_JamArea2202\".stJam2202_4", + "to": "TRO358", + "kind": "normal" + } + ] + }, + { + "id": "TRO361", + "fbType": "1Sep1Swi", + "comment": "TRO 361 (1Sep1Switch)+Scanner(BX3131)", + "entries": [ + { + "jamArea": "JA2304_1", + "dbRef": "\"DB_JamArea2304\".stJam2304_1", + "from": "TRO316", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2304_2", + "dbRef": "\"DB_JamArea2304\".stJam2304_2", + "to": "TRO362", + "kind": "dir2" + }, + { + "jamArea": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_3", + "dbRef": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_3", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO362", + "fbType": "1Sep1Swi", + "comment": "TRO 362 (1Sep1Switch)+Scanner(BX3132)", + "entries": [ + { + "jamArea": "JA2304_2", + "dbRef": "\"DB_JamArea2304\".stJam2304_2", + "from": "TRO361", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2303_1", + "dbRef": "\"DB_JamArea2303\".stJam2303_1", + "to": "TRO374", + "kind": "normal" + }, + { + "jamArea": "JA2304_3", + "dbRef": "\"DB_JamArea2304\".stJam2304_3", + "to": "TRO377", + "kind": "dir2" + } + ] + }, + { + "id": "TRO363", + "fbType": "1Sep1Swi", + "comment": "TRO 363 (1Sep1Switch)+Scanner(BX3137)", + "entries": [ + { + "jamArea": "JA2301_1", + "dbRef": "\"DB_JamArea2301\".stJam2301_1", + "from": "TRO371", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2301_2", + "dbRef": "\"DB_JamArea2301\".stJam2301_2", + "to": "TRO364", + "kind": "normal" + }, + { + "jamArea": "JA2305_1", + "dbRef": "\"DB_JamArea2305\".stJam2305_1", + "to": "TRO372", + "kind": "dir2" + } + ] + }, + { + "id": "TRO364", + "fbType": "1Sep1Swi", + "comment": "TRO 364 (1Sep1Switch)+Scanner(BX3138)", + "entries": [ + { + "jamArea": "JA2301_2", + "dbRef": "\"DB_JamArea2301\".stJam2301_2", + "from": "TRO374", + "kind": "normal" + }, + { + "jamArea": "JA2301_2", + "dbRef": "\"DB_JamArea2301\".stJam2301_2", + "from": "TRO363", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2302_3", + "dbRef": "\"DB_JamArea2302\".stJam2302_3", + "to": "TRO367", + "kind": "normal" + }, + { + "jamArea": "JA2306_1", + "dbRef": "\"DB_JamArea2306\".stJam2306_1", + "to": "TRO375", + "kind": "dir2" + } + ] + }, + { + "id": "TRO365", + "fbType": "1Sep1Swi", + "comment": "TRO 365 (1Sep1Switch)+Scanner(BX3140)", + "entries": [ + { + "jamArea": "JA2302_1", + "dbRef": "\"DB_JamArea2302\".stJam2302_1", + "from": "TRO380", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2302_2", + "dbRef": "\"DB_JamArea2302\".stJam2302_2", + "to": "TRO366", + "kind": "dir2" + }, + { + "jamArea": "JA2308_1", + "dbRef": "\"DB_JamArea2308\".stJam2308_1", + "to": "TRO381", + "kind": "normal" + } + ] + }, + { + "id": "TRO366", + "fbType": "1Sep1Swi", + "comment": "TRO 366 (1Sep1Switch)+Scanner(BX3139)", + "entries": [ + { + "jamArea": "JA2302_2", + "dbRef": "\"DB_JamArea2302\".stJam2302_2", + "from": "TRO377", + "kind": "normal" + }, + { + "jamArea": "JA2302_2", + "dbRef": "\"DB_JamArea2302\".stJam2302_2", + "from": "TRO365", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2302_3", + "dbRef": "\"DB_JamArea2302\".stJam2302_3", + "to": "TRO367", + "kind": "dir2" + }, + { + "jamArea": "JA2307_1", + "dbRef": "\"DB_JamArea2307\".stJam2307_1", + "to": "TRO378", + "kind": "normal" + } + ] + }, + { + "id": "TRO367", + "fbType": "1Sep", + "comment": "TRO 367 (1Sep)", + "entries": [ + { + "jamArea": "JA2302_3", + "dbRef": "\"DB_JamArea2302\".stJam2302_3", + "from": "TRO364", + "kind": "normal" + }, + { + "jamArea": "JA2302_3", + "dbRef": "\"DB_JamArea2302\".stJam2302_3", + "from": "TRO366", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2302_4", + "dbRef": "\"DB_JamArea2302\".stJam2302_4", + "to": "TRO370", + "kind": "normal" + } + ] + }, + { + "id": "TRO368", + "fbType": "Vario", + "comment": "TRO 368 (Vario, from Lvl1)", + "entries": [ + { + "jamArea": "JA2309_1", + "dbRef": "\"DB_JamArea2309\".stJam2309_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2309_2", + "dbRef": "\"DB_JamArea2309\".stJam2309_2", + "to": "TRO369", + "kind": "finger" + } + ] + }, + { + "id": "TRO369", + "fbType": "1Sep", + "comment": "TRO 369 (1Sep)", + "entries": [ + { + "jamArea": "JA2309_2", + "dbRef": "\"DB_JamArea2309\".stJam2309_2", + "from": "TRO368", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2302_4", + "dbRef": "\"DB_JamArea2302\".stJam2302_4", + "to": "TRO370", + "kind": "normal" + } + ] + }, + { + "id": "TRO370", + "fbType": "1Sep", + "comment": "TRO 370 (1Sep)", + "entries": [ + { + "jamArea": "JA2302_4", + "dbRef": "\"DB_JamArea2302\".stJam2302_4", + "from": "TRO367", + "kind": "normal" + }, + { + "jamArea": "JA2302_4", + "dbRef": "\"DB_JamArea2302\".stJam2302_4", + "from": "TRO369", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_2", + "dbRef": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_2", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO371", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO371", + "entries": [ + { + "jamArea": "JA2303_2", + "dbRef": "\"DB_JamArea2303\".stJam2303_2", + "from": "TRO374", + "kind": "bypass" + }, + { + "jamArea": "JA2303_2", + "dbRef": "\"DB_JamArea2303\".stJam2303_2", + "from": "TRO373", + "kind": "normal" + }, + { + "jamArea": "Storage2.3.1", + "dbRef": "Storage2.3.1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2301_1", + "dbRef": "\"DB_JamArea2301\".stJam2301_1", + "to": "TRO363", + "kind": "normal" + } + ] + }, + { + "id": "TRO372", + "fbType": "Vario", + "comment": "TRO 372 (Vario)", + "entries": [ + { + "jamArea": "JA2305_1", + "dbRef": "\"DB_JamArea2305\".stJam2305_1", + "from": "TRO363", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2305_2", + "dbRef": "\"DB_JamArea2305\".stJam2305_2", + "to": "TRO373", + "kind": "finger" + } + ] + }, + { + "id": "TRO373", + "fbType": "1Sep", + "comment": "TRO 373 (1Sep)", + "entries": [ + { + "jamArea": "JA2305_2", + "dbRef": "\"DB_JamArea2305\".stJam2305_2", + "from": "TRO372", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2303_2", + "dbRef": "\"DB_JamArea2303\".stJam2303_2", + "to": "TRO371", + "kind": "normal" + } + ] + }, + { + "id": "TRO374", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO374", + "entries": [ + { + "jamArea": "JA2303_1", + "dbRef": "\"DB_JamArea2303\".stJam2303_1", + "from": "TRO362", + "kind": "normal" + }, + { + "jamArea": "JA2303_1", + "dbRef": "\"DB_JamArea2303\".stJam2303_1", + "from": "TRO376", + "kind": "normal" + }, + { + "jamArea": "Storage2.3.2", + "dbRef": "Storage2.3.2", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2301_2", + "dbRef": "\"DB_JamArea2301\".stJam2301_2", + "to": "TRO364", + "kind": "normal" + }, + { + "jamArea": "JA2303_2", + "dbRef": "\"DB_JamArea2303\".stJam2303_2", + "to": "TRO371", + "kind": "bypass" + } + ] + }, + { + "id": "TRO375", + "fbType": "Vario", + "comment": "TRO 375 (Vario)", + "entries": [ + { + "jamArea": "JA2306_1", + "dbRef": "\"DB_JamArea2306\".stJam2306_1", + "from": "TRO364", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA2306_2", + "dbRef": "\"DB_JamArea2306\".stJam2306_2", + "to": "TRO376", + "kind": "finger" + } + ] + }, + { + "id": "TRO376", + "fbType": "1Sep", + "comment": "TRO 376 (1Sep)", + "entries": [ + { + "jamArea": "JA2306_2", + "dbRef": "\"DB_JamArea2306\".stJam2306_2", + "from": "TRO375", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2303_1", + "dbRef": "\"DB_JamArea2303\".stJam2303_1", + "to": "TRO374", + "kind": "normal" + } + ] + }, + { + "id": "TRO377", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO377", + "entries": [ + { + "jamArea": "JA2304_3", + "dbRef": "\"DB_JamArea2304\".stJam2304_3", + "from": "TRO362", + "kind": "dir2" + }, + { + "jamArea": "JA2304_3", + "dbRef": "\"DB_JamArea2304\".stJam2304_3", + "from": "TRO379", + "kind": "normal" + }, + { + "jamArea": "Storage2.3.3", + "dbRef": "Storage2.3.3", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2302_2", + "dbRef": "\"DB_JamArea2302\".stJam2302_2", + "to": "TRO366", + "kind": "normal" + }, + { + "jamArea": "JA2304_4", + "dbRef": "\"DB_JamArea2304\".stJam2304_4", + "to": "TRO380", + "kind": "bypass" + } + ] + }, + { + "id": "TRO378", + "fbType": "Vario", + "comment": "TRO 378 (Vario)", + "entries": [ + { + "jamArea": "JA2307_1", + "dbRef": "\"DB_JamArea2307\".stJam2307_1", + "from": "TRO366", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2307_2", + "dbRef": "\"DB_JamArea2307\".stJam2307_2", + "to": "TRO379", + "kind": "finger" + } + ] + }, + { + "id": "TRO379", + "fbType": "1Sep", + "comment": "TRO 379 (1Sep)", + "entries": [ + { + "jamArea": "JA2307_2", + "dbRef": "\"DB_JamArea2307\".stJam2307_2", + "from": "TRO378", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2304_3", + "dbRef": "\"DB_JamArea2304\".stJam2304_3", + "to": "TRO377", + "kind": "normal" + } + ] + }, + { + "id": "TRO380", + "fbType": "PinStore_Auto", + "comment": "Aufruf: TRO380", + "entries": [ + { + "jamArea": "JA2304_4", + "dbRef": "\"DB_JamArea2304\".stJam2304_4", + "from": "TRO377", + "kind": "bypass" + }, + { + "jamArea": "JA2304_4", + "dbRef": "\"DB_JamArea2304\".stJam2304_4", + "from": "TRO382", + "kind": "normal" + }, + { + "jamArea": "Storage2.3.4", + "dbRef": "Storage2.3.4", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA2302_1", + "dbRef": "\"DB_JamArea2302\".stJam2302_1", + "to": "TRO365", + "kind": "normal" + } + ] + }, + { + "id": "TRO381", + "fbType": "Vario", + "comment": "TRO 381 (Vario)", + "entries": [ + { + "jamArea": "JA2308_1", + "dbRef": "\"DB_JamArea2308\".stJam2308_1", + "from": "TRO365", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2308_2", + "dbRef": "\"DB_JamArea2308\".stJam2308_2", + "to": "TRO382", + "kind": "finger" + } + ] + }, + { + "id": "TRO382", + "fbType": "1Sep", + "comment": "TRO 382 (1Sep)", + "entries": [ + { + "jamArea": "JA2308_2", + "dbRef": "\"DB_JamArea2308\".stJam2308_2", + "from": "TRO381", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA2304_4", + "dbRef": "\"DB_JamArea2304\".stJam2304_4", + "to": "TRO380", + "kind": "normal" + } + ] + }, + { + "id": "TRO386", + "fbType": "1Sep", + "comment": "TRO 386 (1Sep) - kam später dazu", + "entries": [ + { + "jamArea": "JA2110_5", + "dbRef": "\"DB_JamArea2110\".stJam2110_5", + "from": "TRO309", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA2110_1", + "dbRef": "\"DB_JamArea2110\".stJam2110_1", + "to": "TRO310", + "kind": "normal" + } + ] + } + ], + "connections": [ + { + "from": "TRO318", + "to": "TRO330", + "jamArea": "JA2101_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2101\".stJam2101_1" + }, + { + "from": "TRO332", + "to": "TRO330", + "jamArea": "JA2101_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2101\".stJam2101_1" + }, + { + "from": "TRO330", + "to": "TRO327", + "jamArea": "JA2101_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea2101\".stJam2101_2" + }, + { + "from": "TRO329", + "to": "TRO327", + "jamArea": "JA2101_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2101\".stJam2101_2" + }, + { + "from": "TRO315", + "to": "TRO317", + "jamArea": "JA2102_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2102\".stJam2102_1" + }, + { + "from": "TRO317", + "to": "TRO318", + "jamArea": "JA2102_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2102\".stJam2102_2" + }, + { + "from": "TRO318", + "to": "TRO333", + "jamArea": "JA2102_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2102\".stJam2102_3" + }, + { + "from": "TRO335", + "to": "TRO333", + "jamArea": "JA2102_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2102\".stJam2102_3" + }, + { + "from": "TRO333", + "to": "TRO336", + "jamArea": "JA2102_4", + "kind": "bypass", + "dbRef": "\"DB_JamArea2102\".stJam2102_4" + }, + { + "from": "TRO338", + "to": "TRO336", + "jamArea": "JA2102_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2102\".stJam2102_4" + }, + { + "from": "TRO327", + "to": "TRO319", + "jamArea": "JA2103_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2103\".stJam2103_1" + }, + { + "from": "TRO330", + "to": "TRO320", + "jamArea": "JA2103_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2103\".stJam2103_2" + }, + { + "from": "TRO319", + "to": "TRO320", + "jamArea": "JA2103_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea2103\".stJam2103_2" + }, + { + "from": "TRO336", + "to": "TRO321", + "jamArea": "JA2104_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_1" + }, + { + "from": "TRO333", + "to": "TRO322", + "jamArea": "JA2104_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_2" + }, + { + "from": "TRO321", + "to": "TRO322", + "jamArea": "JA2104_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_2" + }, + { + "from": "TRO320", + "to": "TRO323", + "jamArea": "JA2104_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea2104\".stJam2104_3" + }, + { + "from": "TRO322", + "to": "TRO323", + "jamArea": "JA2104_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_3" + }, + { + "from": "TRO323", + "to": "TRO326", + "jamArea": "JA2104_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_4" + }, + { + "from": "TRO325", + "to": "TRO326", + "jamArea": "JA2104_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2104\".stJam2104_4" + }, + { + "from": "TRO319", + "to": "TRO328", + "jamArea": "JA2105_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2105\".stJam2105_1" + }, + { + "from": "TRO328", + "to": "TRO329", + "jamArea": "JA2105_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2105\".stJam2105_2" + }, + { + "from": "TRO320", + "to": "TRO331", + "jamArea": "JA2106_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2106\".stJam2106_1" + }, + { + "from": "TRO331", + "to": "TRO332", + "jamArea": "JA2106_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2106\".stJam2106_2" + }, + { + "from": "TRO322", + "to": "TRO334", + "jamArea": "JA2107_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2107\".stJam2107_1" + }, + { + "from": "TRO334", + "to": "TRO335", + "jamArea": "JA2107_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2107\".stJam2107_2" + }, + { + "from": "TRO321", + "to": "TRO337", + "jamArea": "JA2108_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2108\".stJam2108_1" + }, + { + "from": "TRO337", + "to": "TRO338", + "jamArea": "JA2108_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2108\".stJam2108_2" + }, + { + "from": "TRO324", + "to": "TRO325", + "jamArea": "JA2109_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2109\".stJam2109_2" + }, + { + "from": "TRO386", + "to": "TRO310", + "jamArea": "JA2110_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2110\".stJam2110_1" + }, + { + "from": "TRO310", + "to": "TRO313", + "jamArea": "JA2110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2110\".stJam2110_2" + }, + { + "from": "TRO311", + "to": "TRO313", + "jamArea": "JA2110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2110\".stJam2110_2" + }, + { + "from": "TRO312", + "to": "TRO313", + "jamArea": "JA2110_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2110\".stJam2110_2" + }, + { + "from": "TRO313", + "to": "TRO314", + "jamArea": "JA2110_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea2110\".stJam2110_3" + }, + { + "from": "TRO314", + "to": "TRO315", + "jamArea": "JA2110_4", + "kind": "dir2", + "dbRef": "\"DB_JamArea2110\".stJam2110_4" + }, + { + "from": "TRO309", + "to": "TRO386", + "jamArea": "JA2110_5", + "kind": "normal", + "dbRef": "\"DB_JamArea2110\".stJam2110_5" + }, + { + "from": "TRO308", + "to": "TRO309", + "jamArea": "JA2111_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2111\".stJam2111_2" + }, + { + "from": "TRO313", + "to": "TRO316", + "jamArea": "JA2112_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2112\".stJam2112_1" + }, + { + "from": "TRO340", + "to": "TRO352", + "jamArea": "JA2201_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2201\".stJam2201_1" + }, + { + "from": "TRO354", + "to": "TRO352", + "jamArea": "JA2201_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2201\".stJam2201_1" + }, + { + "from": "TRO352", + "to": "TRO349", + "jamArea": "JA2201_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea2201\".stJam2201_2" + }, + { + "from": "TRO351", + "to": "TRO349", + "jamArea": "JA2201_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2201\".stJam2201_2" + }, + { + "from": "TRO314", + "to": "TRO339", + "jamArea": "JA2202_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2202\".stJam2202_1" + }, + { + "from": "TRO339", + "to": "TRO340", + "jamArea": "JA2202_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2202\".stJam2202_2" + }, + { + "from": "TRO340", + "to": "TRO355", + "jamArea": "JA2202_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2202\".stJam2202_3" + }, + { + "from": "TRO357", + "to": "TRO355", + "jamArea": "JA2202_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2202\".stJam2202_3" + }, + { + "from": "TRO355", + "to": "TRO358", + "jamArea": "JA2202_4", + "kind": "bypass", + "dbRef": "\"DB_JamArea2202\".stJam2202_4" + }, + { + "from": "TRO360", + "to": "TRO358", + "jamArea": "JA2202_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2202\".stJam2202_4" + }, + { + "from": "TRO349", + "to": "TRO341", + "jamArea": "JA2203_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2203\".stJam2203_1" + }, + { + "from": "TRO352", + "to": "TRO342", + "jamArea": "JA2203_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2203\".stJam2203_2" + }, + { + "from": "TRO341", + "to": "TRO342", + "jamArea": "JA2203_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea2203\".stJam2203_2" + }, + { + "from": "TRO358", + "to": "TRO343", + "jamArea": "JA2204_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_1" + }, + { + "from": "TRO355", + "to": "TRO344", + "jamArea": "JA2204_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_2" + }, + { + "from": "TRO343", + "to": "TRO344", + "jamArea": "JA2204_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_2" + }, + { + "from": "TRO342", + "to": "TRO345", + "jamArea": "JA2204_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea2204\".stJam2204_3" + }, + { + "from": "TRO344", + "to": "TRO345", + "jamArea": "JA2204_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_3" + }, + { + "from": "TRO345", + "to": "TRO348", + "jamArea": "JA2204_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_4" + }, + { + "from": "TRO347", + "to": "TRO348", + "jamArea": "JA2204_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2204\".stJam2204_4" + }, + { + "from": "TRO341", + "to": "TRO350", + "jamArea": "JA2205_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2205\".stJam2205_1" + }, + { + "from": "TRO350", + "to": "TRO351", + "jamArea": "JA2205_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2205\".stJam2205_2" + }, + { + "from": "TRO342", + "to": "TRO353", + "jamArea": "JA2206_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2206\".stJam2206_1" + }, + { + "from": "TRO353", + "to": "TRO354", + "jamArea": "JA2206_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2206\".stJam2206_2" + }, + { + "from": "TRO344", + "to": "TRO356", + "jamArea": "JA2207_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2207\".stJam2207_1" + }, + { + "from": "TRO356", + "to": "TRO357", + "jamArea": "JA2207_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2207\".stJam2207_2" + }, + { + "from": "TRO343", + "to": "TRO359", + "jamArea": "JA2208_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2208\".stJam2208_1" + }, + { + "from": "TRO359", + "to": "TRO360", + "jamArea": "JA2208_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2208\".stJam2208_2" + }, + { + "from": "TRO346", + "to": "TRO347", + "jamArea": "JA2209_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2209\".stJam2209_2" + }, + { + "from": "TRO371", + "to": "TRO363", + "jamArea": "JA2301_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2301\".stJam2301_1" + }, + { + "from": "TRO374", + "to": "TRO364", + "jamArea": "JA2301_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2301\".stJam2301_2" + }, + { + "from": "TRO363", + "to": "TRO364", + "jamArea": "JA2301_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2301\".stJam2301_2" + }, + { + "from": "TRO380", + "to": "TRO365", + "jamArea": "JA2302_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2302\".stJam2302_1" + }, + { + "from": "TRO377", + "to": "TRO366", + "jamArea": "JA2302_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2302\".stJam2302_2" + }, + { + "from": "TRO365", + "to": "TRO366", + "jamArea": "JA2302_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea2302\".stJam2302_2" + }, + { + "from": "TRO364", + "to": "TRO367", + "jamArea": "JA2302_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2302\".stJam2302_3" + }, + { + "from": "TRO366", + "to": "TRO367", + "jamArea": "JA2302_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea2302\".stJam2302_3" + }, + { + "from": "TRO367", + "to": "TRO370", + "jamArea": "JA2302_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2302\".stJam2302_4" + }, + { + "from": "TRO369", + "to": "TRO370", + "jamArea": "JA2302_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2302\".stJam2302_4" + }, + { + "from": "TRO362", + "to": "TRO374", + "jamArea": "JA2303_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2303\".stJam2303_1" + }, + { + "from": "TRO376", + "to": "TRO374", + "jamArea": "JA2303_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2303\".stJam2303_1" + }, + { + "from": "TRO374", + "to": "TRO371", + "jamArea": "JA2303_2", + "kind": "bypass", + "dbRef": "\"DB_JamArea2303\".stJam2303_2" + }, + { + "from": "TRO373", + "to": "TRO371", + "jamArea": "JA2303_2", + "kind": "normal", + "dbRef": "\"DB_JamArea2303\".stJam2303_2" + }, + { + "from": "TRO316", + "to": "TRO361", + "jamArea": "JA2304_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2304\".stJam2304_1" + }, + { + "from": "TRO361", + "to": "TRO362", + "jamArea": "JA2304_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea2304\".stJam2304_2" + }, + { + "from": "TRO362", + "to": "TRO377", + "jamArea": "JA2304_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea2304\".stJam2304_3" + }, + { + "from": "TRO379", + "to": "TRO377", + "jamArea": "JA2304_3", + "kind": "normal", + "dbRef": "\"DB_JamArea2304\".stJam2304_3" + }, + { + "from": "TRO377", + "to": "TRO380", + "jamArea": "JA2304_4", + "kind": "bypass", + "dbRef": "\"DB_JamArea2304\".stJam2304_4" + }, + { + "from": "TRO382", + "to": "TRO380", + "jamArea": "JA2304_4", + "kind": "normal", + "dbRef": "\"DB_JamArea2304\".stJam2304_4" + }, + { + "from": "TRO363", + "to": "TRO372", + "jamArea": "JA2305_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2305\".stJam2305_1" + }, + { + "from": "TRO372", + "to": "TRO373", + "jamArea": "JA2305_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2305\".stJam2305_2" + }, + { + "from": "TRO364", + "to": "TRO375", + "jamArea": "JA2306_1", + "kind": "dir2", + "dbRef": "\"DB_JamArea2306\".stJam2306_1" + }, + { + "from": "TRO375", + "to": "TRO376", + "jamArea": "JA2306_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2306\".stJam2306_2" + }, + { + "from": "TRO366", + "to": "TRO378", + "jamArea": "JA2307_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2307\".stJam2307_1" + }, + { + "from": "TRO378", + "to": "TRO379", + "jamArea": "JA2307_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2307\".stJam2307_2" + }, + { + "from": "TRO365", + "to": "TRO381", + "jamArea": "JA2308_1", + "kind": "normal", + "dbRef": "\"DB_JamArea2308\".stJam2308_1" + }, + { + "from": "TRO381", + "to": "TRO382", + "jamArea": "JA2308_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2308\".stJam2308_2" + }, + { + "from": "TRO368", + "to": "TRO369", + "jamArea": "JA2309_2", + "kind": "finger", + "dbRef": "\"DB_JamArea2309\".stJam2309_2" + }, + { + "from": "TRO300", + "to": "TRO302", + "jamArea": "JA4101_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4101\".stJam4101_1" + }, + { + "from": "TRO301", + "to": "TRO302", + "jamArea": "JA4101_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4101\".stJam4101_1" + }, + { + "from": "TRO302", + "to": "TRO311", + "jamArea": "JA4101_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4101\".stJam4101_2" + }, + { + "from": "TRO303", + "to": "TRO305", + "jamArea": "JA4201_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4201\".stJam4201_1" + }, + { + "from": "TRO304", + "to": "TRO305", + "jamArea": "JA4201_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4201\".stJam4201_1" + }, + { + "from": "TRO305", + "to": "TRO312", + "jamArea": "JA4201_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4201\".stJam4201_2" + } + ], + "externals": [ + { + "node": "TRO336", + "direction": "out", + "jamArea": "JA2102_5", + "dbRef": "\"DB_JamArea2102\".stJam2102_5" + }, + { + "node": "TRO324", + "direction": "in", + "jamArea": "JA2109_1", + "dbRef": "\"DB_JamArea2109\".stJam2109_1" + }, + { + "node": "TRO308", + "direction": "in", + "jamArea": "JA2111_1", + "dbRef": "\"DB_JamArea2111\".stJam2111_1" + }, + { + "node": "TRO358", + "direction": "out", + "jamArea": "JA2202_5", + "dbRef": "\"DB_JamArea2202\".stJam2202_5" + }, + { + "node": "TRO346", + "direction": "in", + "jamArea": "JA2209_1", + "dbRef": "\"DB_JamArea2209\".stJam2209_1" + }, + { + "node": "TRO368", + "direction": "in", + "jamArea": "JA2309_1", + "dbRef": "\"DB_JamArea2309\".stJam2309_1" + }, + { + "node": "TRO300", + "direction": "in", + "jamArea": "JA4102_1", + "dbRef": "\"DB_JamArea4102\".stJam4102_1" + }, + { + "node": "TRO301", + "direction": "in", + "jamArea": "JA4102_2", + "dbRef": "\"DB_JamArea4102\".stJam4102_2" + }, + { + "node": "TRO303", + "direction": "in", + "jamArea": "JA4202_1", + "dbRef": "\"DB_JamArea4202\".stJam4202_1" + }, + { + "node": "TRO304", + "direction": "in", + "jamArea": "JA4202_2", + "dbRef": "\"DB_JamArea4202\".stJam4202_2" + }, + { + "node": "TRO306", + "direction": "in", + "jamArea": "JA4301_1", + "dbRef": "\"DB_JamArea4301\".stJam4301_1" + }, + { + "node": "TRO307", + "direction": "in", + "jamArea": "JA4401_1", + "dbRef": "\"DB_JamArea4401\".stJam4401_1" + }, + { + "node": "TRO327", + "direction": "in", + "jamArea": "Storage2.1.1", + "dbRef": "Storage2.1.1" + }, + { + "node": "TRO330", + "direction": "in", + "jamArea": "Storage2.1.2", + "dbRef": "Storage2.1.2" + }, + { + "node": "TRO333", + "direction": "in", + "jamArea": "Storage2.1.3", + "dbRef": "Storage2.1.3" + }, + { + "node": "TRO336", + "direction": "in", + "jamArea": "Storage2.1.4", + "dbRef": "Storage2.1.4" + }, + { + "node": "TRO349", + "direction": "in", + "jamArea": "Storage2.2.1", + "dbRef": "Storage2.2.1" + }, + { + "node": "TRO352", + "direction": "in", + "jamArea": "Storage2.2.2", + "dbRef": "Storage2.2.2" + }, + { + "node": "TRO355", + "direction": "in", + "jamArea": "Storage2.2.3", + "dbRef": "Storage2.2.3" + }, + { + "node": "TRO358", + "direction": "in", + "jamArea": "Storage2.2.4", + "dbRef": "Storage2.2.4" + }, + { + "node": "TRO371", + "direction": "in", + "jamArea": "Storage2.3.1", + "dbRef": "Storage2.3.1" + }, + { + "node": "TRO374", + "direction": "in", + "jamArea": "Storage2.3.2", + "dbRef": "Storage2.3.2" + }, + { + "node": "TRO377", + "direction": "in", + "jamArea": "Storage2.3.3", + "dbRef": "Storage2.3.3" + }, + { + "node": "TRO380", + "direction": "in", + "jamArea": "Storage2.3.4", + "dbRef": "Storage2.3.4" + }, + { + "node": "TRO326", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCARRIER_INFO", + "dbRef": "IO_Device_UH03_TO_UH01.stCARRIER_INFO" + }, + { + "node": "TRO348", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_1", + "dbRef": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_1" + }, + { + "node": "TRO370", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_2", + "dbRef": "IO_Device_UH03_TO_UH01.stCARRIER_INFO_2" + }, + { + "node": "TRO317", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCarrierL2toL1", + "dbRef": "IO_Device_UH03_TO_UH01.stCarrierL2toL1" + }, + { + "node": "TRO339", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_2", + "dbRef": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_2" + }, + { + "node": "TRO361", + "direction": "out", + "jamArea": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_3", + "dbRef": "IO_Device_UH03_TO_UH01.stCarrierL2toL1_3" + } + ] + } +} \ No newline at end of file diff --git a/results/skeleton_UH04.json b/results/skeleton_UH04.json new file mode 100644 index 0000000..d71cf8b --- /dev/null +++ b/results/skeleton_UH04.json @@ -0,0 +1,3013 @@ +{ + "$schema": "hmf-layout-v1.schema.json", + "generatedBy": "create_skel.py", + "plc": { + "id": "UH04", + "configName": "=A01+UH04-KF00" + }, + "statistics": { + "tags": 203, + "sensors": 134, + "constants": 203, + "units": 14, + "areas": 4, + "unassignedSignals": 47, + "troNodes": 24, + "connections": 25, + "externals": 3 + }, + "sensors": [ + { + "id": "SF0000", + "constant": "cInSF0000", + "hwAddress": "%E000.0", + "comment": "DT Anlage Aus", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 736519.6 + ] + }, + { + "id": "SF0001", + "constant": "cInSF0001", + "hwAddress": "%E000.1", + "comment": "LDT Anlage Ein", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 736249.6 + ] + }, + { + "id": "SF0002", + "constant": "cInSF0002", + "hwAddress": "%E000.2", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 735979.6 + ] + }, + { + "id": "SF0003", + "constant": "cInSF0003", + "hwAddress": "%E000.3", + "comment": "DT Lampentest", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 735709.6 + ] + }, + { + "id": "BP0004", + "constant": "cInBP0004", + "hwAddress": "%E000.4", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UH04", + "pos": [ + 359592.2, + 722561.0 + ] + }, + { + "id": "DI0005", + "constant": "cInDI0005", + "hwAddress": "%E000.5", + "comment": "Phasenausfall 400V", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 733013.8 + ] + }, + { + "id": "DI0006", + "constant": "cInDI0006", + "hwAddress": "%E000.6", + "comment": "Vorsicherung 400V UC Reserve", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 732743.8 + ] + }, + { + "id": "DI0013", + "constant": "cInDI0013", + "hwAddress": "%E001.3", + "comment": "Feedback Hauptschütze aktiv", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361277.5, + 729813.4 + ] + }, + { + "id": "DI0014", + "constant": "cInDI0014", + "hwAddress": "%E001.4", + "comment": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361277.5, + 728660.7 + ] + }, + { + "id": "DI0015", + "constant": "cInDI0015", + "hwAddress": "%E001.5", + "comment": "Feedback Koppelrelais E-Stop-IF", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361274.3, + 727099.6 + ] + }, + { + "id": "DI0016", + "constant": "cInDI0016", + "hwAddress": "%E001.6", + "comment": "Sicherungsautomatenfall", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 732433.7 + ] + }, + { + "id": "DI0021", + "constant": "cInDI0021", + "hwAddress": "%E002.1", + "comment": "Vorsicherung 24V OK (FC021)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 732142.4 + ] + }, + { + "id": "DI0022", + "constant": "cInDI0022", + "hwAddress": "%E002.2", + "comment": "Vorsicherung 24V OK (FC022)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 731872.4 + ] + }, + { + "id": "DI0023", + "constant": "cInDI0023", + "hwAddress": "%E002.3", + "comment": "Vorsicherung 24V OK (FC023)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 731602.4 + ] + }, + { + "id": "SF0025", + "constant": "cInSF0025", + "hwAddress": "%E002.5", + "comment": "MT freigeben UZ0403, Workstation MPS 3", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 344394.8, + 730311.0 + ] + }, + { + "id": "SF0026", + "constant": "cInSF0026", + "hwAddress": "%E002.6", + "comment": "MT freigeben UZ0402, Workstation MPS 2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 344423.5, + 742573.6 + ] + }, + { + "id": "SF0027", + "constant": "cInSF0027", + "hwAddress": "%E002.7", + "comment": "MT freigeben UZ0401, Workstation MPS 1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 344424.9, + 751027.7 + ] + }, + { + "id": "DI0033", + "constant": "cInDI0033", + "hwAddress": "%E003.3", + "comment": "IF BMZ \"fire alarm\" 2", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "DI0034", + "constant": "cInDI0034", + "hwAddress": "%E003.4", + "comment": "IF BMZ \"fire alarm\" 1", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "DI0035", + "constant": "cInDI0035", + "hwAddress": "%E003.5", + "comment": "IF BST 4 \"No fire alarm\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361277.5, + 731243.1 + ] + }, + { + "id": "DI0036", + "constant": "cInDI0036", + "hwAddress": "%E003.6", + "comment": "IF BST 4 \"Non fault\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361277.5, + 730973.1 + ] + }, + { + "id": "DI0037", + "constant": "cInDI0037", + "hwAddress": "%E003.7", + "comment": "IF BST 4 \"FPC opened\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361277.5, + 730703.1 + ] + }, + { + "id": "SF0051", + "constant": "cInSF0051", + "hwAddress": "%E005.1", + "comment": "Reset UZ0409", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 371958.7, + 753262.5 + ] + }, + { + "id": "SF0053", + "constant": "cInSF0053", + "hwAddress": "%E005.3", + "comment": "Reset UZ0403", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 344394.8, + 730569.8 + ] + }, + { + "id": "SF0055", + "constant": "cInSF0055", + "hwAddress": "%E005.5", + "comment": "Reset UZ0402", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 344423.5, + 742832.4 + ] + }, + { + "id": "SF0057", + "constant": "cInSF0057", + "hwAddress": "%E005.7", + "comment": "Reset UZ0401", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 344424.9, + 751286.6 + ] + }, + { + "id": "FC0060", + "constant": "cInFC0060", + "hwAddress": "%E006.0", + "comment": "MSS ausgelöst FC0060", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 361252.4, + 725516.5 + ] + }, + { + "id": "FC0061", + "constant": "cInFC0061", + "hwAddress": "%E006.1", + "comment": "MSS ausgelöst FC0061", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 361252.4, + 725260.3 + ] + }, + { + "id": "FC0062", + "constant": "cInFC0062", + "hwAddress": "%E006.2", + "comment": "MSS ausgelöst FC0062", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 361252.4, + 724976.5 + ] + }, + { + "id": "FC0063", + "constant": "cInFC0063", + "hwAddress": "%E006.3", + "comment": "MSS ausgelöst FC0063", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 361252.4, + 724706.5 + ] + }, + { + "id": "FC0064", + "constant": "cInFC0064", + "hwAddress": "%E006.4", + "comment": "MSS ausgelöst FC0064", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 361252.4, + 724436.5 + ] + }, + { + "id": "FC0065", + "constant": "cInFC0065", + "hwAddress": "%E006.5", + "comment": "MSS ausgelöst FC0065", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 361252.4, + 724166.5 + ] + }, + { + "id": "FC0066", + "constant": "cInFC0066", + "hwAddress": "%E006.6", + "comment": "MSS ausgelöst FC0066", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 361261.4, + 723906.3 + ] + }, + { + "id": "FC0070", + "constant": "cInFC0070", + "hwAddress": "%E007.0", + "comment": "MSS ausgelöst FC0070", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 363741.6, + 725506.6 + ] + }, + { + "id": "FC0071", + "constant": "cInFC0071", + "hwAddress": "%E007.1", + "comment": "MSS ausgelöst FC0071", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 363727.9, + 725246.5 + ] + }, + { + "id": "FC0072", + "constant": "cInFC0072", + "hwAddress": "%E007.2", + "comment": "MSS ausgelöst FC0072", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 363727.9, + 724976.5 + ] + }, + { + "id": "FC0073", + "constant": "cInFC0073", + "hwAddress": "%E007.3", + "comment": "MSS ausgelöst FC0073", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 363727.9, + 724706.5 + ] + }, + { + "id": "FC0074", + "constant": "cInFC0074", + "hwAddress": "%E007.4", + "comment": "MSS ausgelöst FC0074", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 363727.9, + 724436.5 + ] + }, + { + "id": "FC0075", + "constant": "cInFC0075", + "hwAddress": "%E007.5", + "comment": "MSS ausgelöst FC0075 (Reserve)", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 363727.9, + 724166.5 + ] + }, + { + "id": "SF0400", + "constant": "cInSF0400", + "hwAddress": "%E040.0", + "comment": "Not Halt Kanal 1 UH04", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 734089.6 + ] + }, + { + "id": "SF0404", + "constant": "cInSF0404", + "hwAddress": "%E040.4", + "comment": "Not Halt Kanal 2 UH04", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361270.8, + 733819.6 + ] + }, + { + "id": "SF0471", + "constant": "cInSF0471", + "hwAddress": "%E047.1", + "comment": "Not Halt Schnittstelle CH1 (UH06)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361274.3, + 728083.1 + ] + }, + { + "id": "SF0472", + "constant": "cInSF0472", + "hwAddress": "%E047.2", + "comment": "Not Halt Schnittstelle CH2 (Reserve)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361274.3, + 727813.1 + ] + }, + { + "id": "SF0473", + "constant": "cInSF0473", + "hwAddress": "%E047.3", + "comment": "Not Halt Kanal 1 UZ0409", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 371958.7, + 752962.2 + ] + }, + { + "id": "SF0475", + "constant": "cInSF0475", + "hwAddress": "%E047.5", + "comment": "Not Halt Schnittstelle CH1 (UH06)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361274.3, + 726559.6 + ] + }, + { + "id": "SF0476", + "constant": "cInSF0476", + "hwAddress": "%E047.6", + "comment": "Not Halt Schnittstelle CH2 (Reserve)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 361274.3, + 726289.6 + ] + }, + { + "id": "SF0477", + "constant": "cInSF0477", + "hwAddress": "%E047.7", + "comment": "Not Halt Kanal 2 UZ0409", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 371958.7, + 752692.2 + ] + }, + { + "id": "BG3240", + "constant": "cInBG3240", + "hwAddress": "%E324.0", + "comment": "Sensor Förderer voll (ILS-CV M4000)", + "role": "sensorConvFull", + "unit": "M4000", + "cabinet": "UC0401", + "pos": [ + 378165.9, + 752021.3 + ] + }, + { + "id": "BG3241", + "constant": "cInBG3241", + "hwAddress": "%E324.1", + "comment": "MT in Position MPS 3 (AMR ILS-CV M04001)", + "role": "sensorCarrInPos", + "unit": null, + "cabinet": "UC0401", + "pos": [ + 378156.7, + 750287.5 + ] + }, + { + "id": "BG3242", + "constant": "cInBG3242", + "hwAddress": "%E324.2", + "comment": "in Separator (ILS-CV M4001)", + "role": "sensorInSep", + "unit": "M4001", + "cabinet": "UC0401", + "pos": [ + 378153.0, + 750860.4 + ] + }, + { + "id": "BG3243", + "constant": "cInBG3243", + "hwAddress": "%E324.3", + "comment": "Stausensor (AMR ILS-CV M4000)", + "role": "sensorJam", + "unit": "M4000", + "cabinet": "UC0401", + "pos": [ + 378153.2, + 751438.6 + ] + }, + { + "id": "BG3244", + "constant": "cInBG3244", + "hwAddress": "%E324.4", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4001)", + "role": "sensorFinger", + "unit": "M4001", + "cabinet": "UC0401", + "pos": [ + 378163.4, + 750557.6 + ] + }, + { + "id": "BG3245", + "constant": "cInBG3245", + "hwAddress": "%E324.5", + "comment": "Sensor Förderer voll (ILS-CV M4001)", + "role": "sensorConvFull", + "unit": "M4001", + "cabinet": "UC0401", + "pos": [ + 362625.4, + 752187.3 + ] + }, + { + "id": "BG3246", + "constant": "cInBG3246", + "hwAddress": "%E324.6", + "comment": "Stausensor vor Vario Förderer (ILS-CV M4001)", + "role": "sensorJam", + "unit": "M4001", + "cabinet": "UC0401", + "pos": [ + 361367.2, + 752187.3 + ] + }, + { + "id": "BG3247", + "constant": "cInBG3247", + "hwAddress": "%E324.7", + "comment": "in Separator vor BST 4 (ILS-CV M4001)", + "role": "sensorInSep", + "unit": "M4001", + "cabinet": null, + "pos": null + }, + { + "id": "BG3250", + "constant": "cInBG3250", + "hwAddress": "%E325.0", + "comment": "in Separator (ILS-CV M4011)", + "role": "sensorInSep", + "unit": "M4011", + "cabinet": "UC0401", + "pos": [ + 360632.7, + 750259.0 + ] + }, + { + "id": "BG3251", + "constant": "cInBG3251", + "hwAddress": "%E325.1", + "comment": "Stausensor (AMR ILS-CV M4503)", + "role": "sensorJam", + "unit": "M4503", + "cabinet": "UC0401", + "pos": [ + 380629.7, + 750474.8 + ] + }, + { + "id": "BG3253", + "constant": "cInBG3253", + "hwAddress": "%E325.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M4011)", + "role": "sensorFinger", + "unit": "M4011", + "cabinet": "UC0401", + "pos": [ + 361074.8, + 750814.3 + ] + }, + { + "id": "BG3255", + "constant": "cInBG3255", + "hwAddress": "%E325.5", + "comment": "MT in Position (ILS-CV M4011)", + "role": "sensorCarrInPos", + "unit": "M4011", + "cabinet": "UC0401", + "pos": [ + 361545.5, + 751087.8 + ] + }, + { + "id": "BG3256", + "constant": "cInBG3256", + "hwAddress": "%E325.6", + "comment": "Sensor Förderer voll (ILS-CV M4011)", + "role": "sensorConvFull", + "unit": "M4011", + "cabinet": "UC0401", + "pos": [ + 380629.7, + 749879.2 + ] + }, + { + "id": "BG3260", + "constant": "cInBG3260", + "hwAddress": "%E326.0", + "comment": "in Separator 4 (ILS-CV M0401)", + "role": "sensorInSep", + "unit": "M0401", + "cabinet": "UC0401", + "pos": [ + 363417.8, + 451848.4 + ] + }, + { + "id": "BG3261", + "constant": "cInBG3261", + "hwAddress": "%E326.1", + "comment": "MT in Position (AMR ILS-CV M0401)", + "role": "sensorCarrInPos", + "unit": "M0401", + "cabinet": "UC0401", + "pos": [ + 364916.8, + 452104.3 + ] + }, + { + "id": "BG3262", + "constant": "cInBG3262", + "hwAddress": "%E326.2", + "comment": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M0401)", + "role": "sensorFinger", + "unit": "M0401", + "cabinet": "UC0401", + "pos": [ + 364161.1, + 452111.8 + ] + }, + { + "id": "BG3264", + "constant": "cInBG3264", + "hwAddress": "%E326.4", + "comment": "Stausensor nach BST 4 (AMR ILS-CV M4011)", + "role": "sensorJam", + "unit": "M4011", + "cabinet": null, + "pos": null + }, + { + "id": "BG3300", + "constant": "cInBG3300", + "hwAddress": "%E330.0", + "comment": "in Separator 6 (AMR KR-M4003)", + "role": "sensorInSep", + "unit": "M4003", + "cabinet": "UC0402", + "pos": [ + 358556.7, + 725734.7 + ] + }, + { + "id": "BG3301", + "constant": "cInBG3301", + "hwAddress": "%E330.1", + "comment": "Stausensor 6 (AMR ILS-KR M4003)", + "role": "sensorJam", + "unit": "M4003", + "cabinet": "UC0402", + "pos": [ + 358561.3, + 736492.4 + ] + }, + { + "id": "BG3303", + "constant": "cInBG3303", + "hwAddress": "%E330.3", + "comment": "Stausensor (AMR KR-M4003)", + "role": "sensorJam", + "unit": "M4003", + "cabinet": "UC0402", + "pos": [ + 356396.7, + 725377.9 + ] + }, + { + "id": "BG3304", + "constant": "cInBG3304", + "hwAddress": "%E330.4", + "comment": "in Separator vor MPS 3 (AMR KR-M4003)", + "role": "sensorInSep", + "unit": "M4003", + "cabinet": "UC0402", + "pos": [ + 356209.0, + 727409.8 + ] + }, + { + "id": "BG3311", + "constant": "cInBG3311", + "hwAddress": "%E331.1", + "comment": "Stausensor (AMR ILS-CV M4004)", + "role": "sensorJam", + "unit": "M4004", + "cabinet": "UC0402", + "pos": [ + 356303.6, + 728860.8 + ] + }, + { + "id": "BG3312", + "constant": "cInBG3312", + "hwAddress": "%E331.2", + "comment": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4004)", + "role": "sensorFinger", + "unit": "M4004", + "cabinet": "UC0402", + "pos": [ + 353870.5, + 728861.9 + ] + }, + { + "id": "BG3313", + "constant": "cInBG3313", + "hwAddress": "%E331.3", + "comment": "Sensor Förderer voll (AMR ILS-CV M4004) MPS 3", + "role": "sensorConvFull", + "unit": "M4004", + "cabinet": "UC0402", + "pos": [ + 351217.4, + 728296.4 + ] + }, + { + "id": "BG3314", + "constant": "cInBG3314", + "hwAddress": "%E331.4", + "comment": "MT in Entladeposition MPS 3 (AMR ILS-CV M4005)", + "role": "sensorCarrInPos", + "unit": "M4005", + "cabinet": "UC0402", + "pos": [ + 349070.3, + 728587.0 + ] + }, + { + "id": "BG3315", + "constant": "cInBG3315", + "hwAddress": "%E331.5", + "comment": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4005) MPS 3", + "role": "sensorFinger", + "unit": "M4005", + "cabinet": "UC0402", + "pos": [ + 350450.1, + 728297.6 + ] + }, + { + "id": "BG3316", + "constant": "cInBG3316", + "hwAddress": "%E331.6", + "comment": "MT in Position MPS 3 (AMR ILS-CV M4004)", + "role": "sensorCarrInPos", + "unit": "M4004", + "cabinet": "UC0402", + "pos": [ + 353380.7, + 728299.8 + ] + }, + { + "id": "BG3317", + "constant": "cInBG3317", + "hwAddress": "%E331.7", + "comment": "Sensor Förderer voll (AMR ILS-CV M4005)", + "role": "sensorConvFull", + "unit": "M4005", + "cabinet": "UC0402", + "pos": [ + 354258.5, + 730017.2 + ] + }, + { + "id": "BG3320", + "constant": "cInBG3320", + "hwAddress": "%E332.0", + "comment": "Stausensor (AMR ILS-CV M4005)", + "role": "sensorJam", + "unit": "M4005", + "cabinet": "UC0402", + "pos": [ + 355126.8, + 730017.2 + ] + }, + { + "id": "BG3321", + "constant": "cInBG3321", + "hwAddress": "%E332.1", + "comment": "in Separator Ausfahrt MPS 3 (AMR ILS-CV M4005)", + "role": "sensorInSep", + "unit": "M4005", + "cabinet": "UC0402", + "pos": [ + 356132.3, + 730012.0 + ] + }, + { + "id": "BG3322", + "constant": "cInBG3322", + "hwAddress": "%E332.2", + "comment": "Stausensor Ausfahrt MPS 03 (AMR ILS-KR M4003)", + "role": "sensorJam", + "unit": "M4003", + "cabinet": "UC0402", + "pos": [ + 356441.4, + 730594.7 + ] + }, + { + "id": "BG3324", + "constant": "cInBG3324", + "hwAddress": "%E332.4", + "comment": "MT in Position MPS 3 (AMR ILS-CV M4005)", + "role": "sensorCarrInPos", + "unit": "M4005", + "cabinet": "UC0402", + "pos": [ + 349648.4, + 728259.4 + ] + }, + { + "id": "BG3325", + "constant": "cInBG3325", + "hwAddress": "%E332.5", + "comment": "MT ist beladen MPS 3 (AMR ILS-CV M4005)", + "role": null, + "unit": "M4005", + "cabinet": "UC0402", + "pos": [ + 349115.1, + 729620.8 + ] + }, + { + "id": "BG3326", + "constant": "cInBG3326", + "hwAddress": "%E332.6", + "comment": "in Separator (AMR ILS-CV M4005)", + "role": "sensorInSep", + "unit": "M4005", + "cabinet": null, + "pos": null + }, + { + "id": "BG3327", + "constant": "cInBG3327", + "hwAddress": "%E332.7", + "comment": "Stausensor (AMR ILS-CV M4004)", + "role": "sensorJam", + "unit": "M4004", + "cabinet": null, + "pos": null + }, + { + "id": "BG3360", + "constant": "cInBG3360", + "hwAddress": "%E336.0", + "comment": "in Separator (AMR ILS-KR M4003)", + "role": "sensorInSep", + "unit": "M4003", + "cabinet": "UC0403", + "pos": [ + 358297.5, + 738267.2 + ] + }, + { + "id": "BG3361", + "constant": "cInBG3361", + "hwAddress": "%E336.1", + "comment": "MT ist beladen (AMR KR-M4003)", + "role": null, + "unit": "M4003", + "cabinet": null, + "pos": null + }, + { + "id": "BG3362", + "constant": "cInBG3362", + "hwAddress": "%E336.2", + "comment": "Stausensor 5 (AMR ILS-KR M4003)", + "role": "sensorJam", + "unit": "M4003", + "cabinet": "UC0403", + "pos": [ + 359583.0, + 737534.8 + ] + }, + { + "id": "BG3363", + "constant": "cInBG3363", + "hwAddress": "%E336.3", + "comment": "in Separator 5 (AMR ILS-KR M4003)", + "role": "sensorInSep", + "unit": "M4003", + "cabinet": "UC0403", + "pos": [ + 356336.6, + 739165.7 + ] + }, + { + "id": "BG3367", + "constant": "cInBG3367", + "hwAddress": "%E336.7", + "comment": "Stausensor 4 (AMR ILS-KR M4003)", + "role": "sensorJam", + "unit": "M4003", + "cabinet": "UC0403", + "pos": [ + 358307.0, + 739968.5 + ] + }, + { + "id": "BG3370", + "constant": "cInBG3370", + "hwAddress": "%E337.0", + "comment": "in Separator (AMR ILS-CV M4006)", + "role": "sensorInSep", + "unit": "M4006", + "cabinet": "UC0403", + "pos": [ + 354359.3, + 740059.4 + ] + }, + { + "id": "BG3371", + "constant": "cInBG3371", + "hwAddress": "%E337.1", + "comment": "Stausensor 3 (AMR ILS-CV M4006)", + "role": "sensorJam", + "unit": "M4006", + "cabinet": "UC0403", + "pos": [ + 356313.6, + 740885.8 + ] + }, + { + "id": "BG3372", + "constant": "cInBG3372", + "hwAddress": "%E337.2", + "comment": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4006)", + "role": "sensorFinger", + "unit": "M4006", + "cabinet": "UC0403", + "pos": [ + 353864.3, + 740884.8 + ] + }, + { + "id": "BG3373", + "constant": "cInBG3373", + "hwAddress": "%E337.3", + "comment": "Sensor Förderer voll (AMR ILS-CV M4006)", + "role": "sensorConvFull", + "unit": "M4006", + "cabinet": "UC0403", + "pos": [ + 351207.8, + 740303.0 + ] + }, + { + "id": "BG3374", + "constant": "cInBG3374", + "hwAddress": "%E337.4", + "comment": "MT IN Entladeposition MPS- (AMR ILS-CV M4007)", + "role": "sensorCarrInPos", + "unit": "M4007", + "cabinet": "UC0403", + "pos": [ + 349074.0, + 740611.0 + ] + }, + { + "id": "BG3375", + "constant": "cInBG3375", + "hwAddress": "%E337.5", + "comment": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4007) MPS 2", + "role": "sensorFinger", + "unit": "M4007", + "cabinet": "UC0403", + "pos": [ + 350434.2, + 740309.8 + ] + }, + { + "id": "BG3376", + "constant": "cInBG3376", + "hwAddress": "%E337.6", + "comment": "MT in Position MPS 2 (AMR ILS-CV M4006)", + "role": "sensorCarrInPos", + "unit": "M4006", + "cabinet": "UC0403", + "pos": [ + 353389.1, + 740318.9 + ] + }, + { + "id": "BG3377", + "constant": "cInBG3377", + "hwAddress": "%E337.7", + "comment": "Sensor Förderer voll (AMR ILS-CV M4007)", + "role": "sensorConvFull", + "unit": "M4007", + "cabinet": "UC0403", + "pos": [ + 354602.4, + 742009.9 + ] + }, + { + "id": "BG3380", + "constant": "cInBG3380", + "hwAddress": "%E338.0", + "comment": "Stausensor (AMR ILS-CV M4007)", + "role": "sensorJam", + "unit": "M4007", + "cabinet": "UC0403", + "pos": [ + 355383.5, + 742006.0 + ] + }, + { + "id": "BG3381", + "constant": "cInBG3381", + "hwAddress": "%E338.1", + "comment": "in Separator Ausfahrt MPS 2 (AMR ILS-CV M4007)", + "role": "sensorInSep", + "unit": "M4007", + "cabinet": "UC0403", + "pos": [ + 356210.6, + 742000.8 + ] + }, + { + "id": "BG3382", + "constant": "cInBG3382", + "hwAddress": "%E338.2", + "comment": "Stausensor Ausfahrt MPS 02 (AMR ILS-KR M04003)", + "role": "sensorJam", + "unit": null, + "cabinet": "UC0403", + "pos": [ + 356441.4, + 742619.7 + ] + }, + { + "id": "BG3383", + "constant": "cInBG3383", + "hwAddress": "%E338.3", + "comment": "in Separator (AMR ILS-KR M4003)", + "role": "sensorInSep", + "unit": "M4003", + "cabinet": "UC0403", + "pos": [ + 357632.4, + 741620.4 + ] + }, + { + "id": "BG3384", + "constant": "cInBG3384", + "hwAddress": "%E338.4", + "comment": "MT in Position MPS 2 (AMR ILS-CV M4007)", + "role": "sensorCarrInPos", + "unit": "M4007", + "cabinet": "UC0403", + "pos": [ + 349648.4, + 740289.4 + ] + }, + { + "id": "BG3385", + "constant": "cInBG3385", + "hwAddress": "%E338.5", + "comment": "MT ist beladen MPS 2 (AMR ILS-CV M4007)", + "role": null, + "unit": "M4007", + "cabinet": "UC0404", + "pos": [ + 349115.1, + 741650.8 + ] + }, + { + "id": "BG3386", + "constant": "cInBG3386", + "hwAddress": "%E338.6", + "comment": "in Separator (AMR ILS-CV M4002)", + "role": "sensorInSep", + "unit": "M4002", + "cabinet": "UC0403", + "pos": [ + 358787.8, + 741472.9 + ] + }, + { + "id": "BG3387", + "constant": "cInBG3387", + "hwAddress": "%E338.7", + "comment": "Stausensor 3 (AMR ILS-CV M4002)", + "role": "sensorJam", + "unit": "M4002", + "cabinet": "UC0403", + "pos": [ + 358794.0, + 742511.8 + ] + }, + { + "id": "BG3390", + "constant": "cInBG3390", + "hwAddress": "%E339.0", + "comment": "Sensor Förderer voll (AMR ILS-CV M4002)", + "role": "sensorConvFull", + "unit": "M4002", + "cabinet": "UC0403", + "pos": [ + 358779.7, + 743254.3 + ] + }, + { + "id": "BG3391", + "constant": "cInBG3391", + "hwAddress": "%E339.1", + "comment": "in Separator (AMR ILS-CV M4010)", + "role": "sensorInSep", + "unit": "M4010", + "cabinet": "UC0403", + "pos": [ + 359609.5, + 743769.1 + ] + }, + { + "id": "BG3392", + "constant": "cInBG3392", + "hwAddress": "%E339.2", + "comment": "MT in Position (ILS-CV M4010)", + "role": "sensorCarrInPos", + "unit": "M4010", + "cabinet": "UC0403", + "pos": [ + 359583.1, + 744859.2 + ] + }, + { + "id": "BG3393", + "constant": "cInBG3393", + "hwAddress": "%E339.3", + "comment": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4010)", + "role": "sensorFinger", + "unit": "M4010", + "cabinet": "UC0403", + "pos": [ + 359596.3, + 744443.4 + ] + }, + { + "id": "BG3396", + "constant": "cInBG3396", + "hwAddress": "%E339.6", + "comment": "Stausensor (AMR ILS-CV M4006)", + "role": "sensorJam", + "unit": "M4006", + "cabinet": null, + "pos": null + }, + { + "id": "BG3397", + "constant": "cInBG3397", + "hwAddress": "%E339.7", + "comment": "in Separator (AMR ILS-CV M4007)", + "role": "sensorInSep", + "unit": "M4007", + "cabinet": null, + "pos": null + }, + { + "id": "BG3400", + "constant": "cInBG3400", + "hwAddress": "%E340.0", + "comment": "in Separator (AMR ILS-KR M4003)", + "role": "sensorInSep", + "unit": "M4003", + "cabinet": null, + "pos": null + }, + { + "id": "BG3420", + "constant": "cInBG3420", + "hwAddress": "%E342.0", + "comment": "in Separator (AMR ILS-CV M4002)", + "role": "sensorInSep", + "unit": "M4002", + "cabinet": "UC0404", + "pos": [ + 359629.3, + 752179.8 + ] + }, + { + "id": "BG3421", + "constant": "cInBG3421", + "hwAddress": "%E342.1", + "comment": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4002)", + "role": "sensorFinger", + "unit": "M4002", + "cabinet": "UC0404", + "pos": [ + 358847.2, + 752169.1 + ] + }, + { + "id": "BG3423", + "constant": "cInBG3423", + "hwAddress": "%E342.3", + "comment": "Stausensor nach BST 4 (AMR ILS-CV M4010)", + "role": "sensorJam", + "unit": "M4010", + "cabinet": "UC0404", + "pos": [ + 359485.4, + 750831.0 + ] + }, + { + "id": "BG3425", + "constant": "cInBG3425", + "hwAddress": "%E342.5", + "comment": "Sensor Förderer voll (ILS-CV M4010)", + "role": "sensorConvFull", + "unit": "M4010", + "cabinet": "UC0404", + "pos": [ + 358595.9, + 750842.9 + ] + }, + { + "id": "BG3426", + "constant": "cInBG3426", + "hwAddress": "%E342.6", + "comment": "MT in Position (ILS-CV M4002)", + "role": "sensorCarrInPos", + "unit": "M4002", + "cabinet": "UC0404", + "pos": [ + 358419.5, + 751919.1 + ] + }, + { + "id": "BG3430", + "constant": "cInBG3430", + "hwAddress": "%E343.0", + "comment": "in Separator vor MPS 1 (AMR KR-M4003)", + "role": "sensorInSep", + "unit": "M4003", + "cabinet": "UC0404", + "pos": [ + 356126.6, + 748763.2 + ] + }, + { + "id": "BG3431", + "constant": "cInBG3431", + "hwAddress": "%E343.1", + "comment": "Stausensor (AMR ILS-CV M4009)", + "role": "sensorJam", + "unit": "M4009", + "cabinet": "UC0404", + "pos": [ + 355162.2, + 751437.5 + ] + }, + { + "id": "BG3432", + "constant": "cInBG3432", + "hwAddress": "%E343.2", + "comment": "Rad dreht (AMR KR-M4003)", + "role": "sensorWheel", + "unit": "M4003", + "cabinet": null, + "pos": null + }, + { + "id": "BG3433", + "constant": "cInBG3433", + "hwAddress": "%E343.3", + "comment": "Stausensor (AMR ILS-KR M4003)", + "role": "sensorJam", + "unit": "M4003", + "cabinet": "UC0404", + "pos": [ + 358239.6, + 752867.2 + ] + }, + { + "id": "BG3435", + "constant": "cInBG3435", + "hwAddress": "%E343.5", + "comment": "in Separator (AMR KR-M4003)", + "role": "sensorInSep", + "unit": "M4003", + "cabinet": "UC0404", + "pos": [ + 355960.7, + 752861.8 + ] + }, + { + "id": "BG3436", + "constant": "cInBG3436", + "hwAddress": "%E343.6", + "comment": "in Separator (AMR ILS-CV M4009)", + "role": "sensorInSep", + "unit": "M4009", + "cabinet": null, + "pos": null + }, + { + "id": "BG3437", + "constant": "cInBG3437", + "hwAddress": "%E343.7", + "comment": "Stausensor (AMR ILS-CV M4008)", + "role": "sensorJam", + "unit": "M4008", + "cabinet": null, + "pos": null + }, + { + "id": "BG3440", + "constant": "cInBG3440", + "hwAddress": "%E344.0", + "comment": "in Separator (AMR ILS-CV M4008)", + "role": "sensorInSep", + "unit": "M4008", + "cabinet": null, + "pos": null + }, + { + "id": "BG3441", + "constant": "cInBG3441", + "hwAddress": "%E344.1", + "comment": "Stausensor 3 (AMR ILS-CV M4008)", + "role": "sensorJam", + "unit": "M4008", + "cabinet": "UC0404", + "pos": [ + 356319.8, + 750384.8 + ] + }, + { + "id": "BG3442", + "constant": "cInBG3442", + "hwAddress": "%E344.2", + "comment": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4008)", + "role": "sensorFinger", + "unit": "M4008", + "cabinet": "UC0404", + "pos": [ + 353896.7, + 750397.5 + ] + }, + { + "id": "BG3443", + "constant": "cInBG3443", + "hwAddress": "%E344.3", + "comment": "Sensor Förderer voll (AMR ILS-CV M4008)", + "role": "sensorConvFull", + "unit": "M4008", + "cabinet": "UC0404", + "pos": [ + 351222.8, + 749801.3 + ] + }, + { + "id": "BG3444", + "constant": "cInBG3444", + "hwAddress": "%E344.4", + "comment": "MT IN Entladeposition MPS- (AMR ILS-CV M4009)", + "role": "sensorCarrInPos", + "unit": "M4009", + "cabinet": "UC0404", + "pos": [ + 349083.1, + 750135.1 + ] + }, + { + "id": "BG3445", + "constant": "cInBG3445", + "hwAddress": "%E344.5", + "comment": "Abfrage Mitnehmerfinger in Position (AMR ILS-CV M4009)", + "role": "sensorFinger", + "unit": "M4009", + "cabinet": "UC0404", + "pos": [ + 350449.8, + 749774.4 + ] + }, + { + "id": "BG3446", + "constant": "cInBG3446", + "hwAddress": "%E344.6", + "comment": "MT in Position MPS 1 (AMR ILS-CV M4008)", + "role": "sensorCarrInPos", + "unit": "M4008", + "cabinet": "UC0404", + "pos": [ + 353385.8, + 749826.2 + ] + }, + { + "id": "BG3447", + "constant": "cInBG3447", + "hwAddress": "%E344.7", + "comment": "Sensor Förderer voll (AMR ILS-CV M4009)", + "role": "sensorConvFull", + "unit": "M4009", + "cabinet": "UC0404", + "pos": [ + 354293.4, + 751447.4 + ] + }, + { + "id": "BG3450", + "constant": "cInBG3450", + "hwAddress": "%E345.0", + "comment": "Stausensor Ausfahrt MPS 01 (AMR ILS-KR M4003)", + "role": "sensorJam", + "unit": "M4003", + "cabinet": "UC0404", + "pos": [ + 356382.4, + 752059.6 + ] + }, + { + "id": "BG3451", + "constant": "cInBG3451", + "hwAddress": "%E345.1", + "comment": "in Separator Ausfahrt MPS 1 (AMR ILS-CV M4009)", + "role": "sensorInSep", + "unit": "M4009", + "cabinet": "UC0404", + "pos": [ + 355970.4, + 751432.4 + ] + }, + { + "id": "BG3454", + "constant": "cInBG3454", + "hwAddress": "%E345.4", + "comment": "MT in Position MPS 1 (AMR ILS-CV M4009)", + "role": "sensorCarrInPos", + "unit": "M4009", + "cabinet": "UC0404", + "pos": [ + 349648.4, + 749789.4 + ] + }, + { + "id": "BG3455", + "constant": "cInBG3455", + "hwAddress": "%E345.5", + "comment": "MT ist beladen MPS 1 (AMR ILS-CV M4009)", + "role": null, + "unit": "M4009", + "cabinet": "UC0404", + "pos": [ + 349115.1, + 751150.8 + ] + } + ], + "units": [ + { + "unit": "M0401", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0401", + "pos": [ + 363417.8, + 451848.4 + ], + "io": { + "sensorInSep": [ + "BG3260" + ], + "sensorCarrInPos": [ + "BG3261" + ], + "sensorFinger": [ + "BG3262" + ], + "stopperOutput": [ + "MB3260" + ] + }, + "signalCount": 4 + }, + { + "unit": "M4000", + "unitKind": "CV", + "fbType": "FB_Conveyor", + "areas": [], + "cabinet": "UC0401", + "pos": [ + 378165.9, + 752021.3 + ], + "io": { + "sensorConvFull": [ + "BG3240" + ], + "sensorJam": [ + "BG3243" + ], + "motorOutput": [ + "MA0070" + ] + }, + "signalCount": 3 + }, + { + "unit": "M4001", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0401", + "pos": [ + 378153.0, + 750860.4 + ], + "io": { + "sensorInSep": [ + "BG3242", + "BG3247" + ], + "sensorFinger": [ + "BG3244" + ], + "sensorConvFull": [ + "BG3245" + ], + "sensorJam": [ + "BG3246" + ], + "motorOutput": [ + "MA0071" + ], + "stopperOutput": [ + "MB3242", + "MB3247" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4002", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0403", + "pos": [ + 358787.8, + 741472.9 + ], + "io": { + "sensorInSep": [ + "BG3386", + "BG3420" + ], + "sensorJam": [ + "BG3387" + ], + "sensorConvFull": [ + "BG3390" + ], + "sensorFinger": [ + "BG3421" + ], + "sensorCarrInPos": [ + "BG3426" + ], + "motorOutput": [ + "MA0073" + ], + "stopperOutput": [ + "MB3386", + "MB3420" + ] + }, + "signalCount": 9 + }, + { + "unit": "M4003", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep1Swi", + "areas": [], + "cabinet": "UC0402", + "pos": [ + 358556.7, + 725734.7 + ], + "io": { + "sensorInSep": [ + "BG3300", + "BG3304", + "BG3360", + "BG3363", + "BG3383", + "BG3400", + "BG3430", + "BG3435" + ], + "sensorJam": [ + "BG3301", + "BG3303", + "BG3322", + "BG3362", + "BG3367", + "BG3433", + "BG3450" + ], + "sensorWheel": [ + "BG3432" + ], + "motorOutput": [ + "MA0060" + ], + "stopperOutput": [ + "MB3300", + "MB3304", + "MB3360", + "MB3363", + "MB3383", + "MB3400", + "MB3430", + "MB3435" + ], + "switchOutput": [ + "MB3362", + "MB3366", + "MB3432" + ] + }, + "signalCount": 29 + }, + { + "unit": "M4004", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0402", + "pos": [ + 356303.6, + 728860.8 + ], + "io": { + "sensorJam": [ + "BG3311", + "BG3327" + ], + "sensorFinger": [ + "BG3312" + ], + "sensorConvFull": [ + "BG3313" + ], + "sensorCarrInPos": [ + "BG3316" + ], + "motorOutput": [ + "MA0061" + ] + }, + "signalCount": 6 + }, + { + "unit": "M4005", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0402", + "pos": [ + 349070.3, + 728587.0 + ], + "io": { + "sensorCarrInPos": [ + "BG3314", + "BG3324" + ], + "sensorFinger": [ + "BG3315" + ], + "sensorConvFull": [ + "BG3317" + ], + "sensorJam": [ + "BG3320" + ], + "sensorInSep": [ + "BG3321", + "BG3326" + ], + "motorOutput": [ + "MA0062" + ], + "stopperOutput": [ + "MB3321", + "MB3326" + ] + }, + "signalCount": 11 + }, + { + "unit": "M4006", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0403", + "pos": [ + 354359.3, + 740059.4 + ], + "io": { + "sensorInSep": [ + "BG3370" + ], + "sensorJam": [ + "BG3371", + "BG3396" + ], + "sensorFinger": [ + "BG3372" + ], + "sensorConvFull": [ + "BG3373" + ], + "sensorCarrInPos": [ + "BG3376" + ], + "motorOutput": [ + "MA0063" + ], + "stopperOutput": [ + "MB3370" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4007", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0403", + "pos": [ + 349074.0, + 740611.0 + ], + "io": { + "sensorCarrInPos": [ + "BG3374", + "BG3384" + ], + "sensorFinger": [ + "BG3375" + ], + "sensorConvFull": [ + "BG3377" + ], + "sensorJam": [ + "BG3380" + ], + "sensorInSep": [ + "BG3381", + "BG3397" + ], + "motorOutput": [ + "MA0064" + ], + "stopperOutput": [ + "MB3381", + "MB3397" + ] + }, + "signalCount": 11 + }, + { + "unit": "M4008", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0404", + "pos": [ + 356319.8, + 750384.8 + ], + "io": { + "sensorJam": [ + "BG3437", + "BG3441" + ], + "sensorInSep": [ + "BG3440" + ], + "sensorFinger": [ + "BG3442" + ], + "sensorConvFull": [ + "BG3443" + ], + "sensorCarrInPos": [ + "BG3446" + ], + "motorOutput": [ + "MA0065" + ], + "stopperOutput": [ + "MB3440" + ] + }, + "signalCount": 8 + }, + { + "unit": "M4009", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0404", + "pos": [ + 355162.2, + 751437.5 + ], + "io": { + "sensorJam": [ + "BG3431" + ], + "sensorInSep": [ + "BG3436", + "BG3451" + ], + "sensorCarrInPos": [ + "BG3444", + "BG3454" + ], + "sensorFinger": [ + "BG3445" + ], + "sensorConvFull": [ + "BG3447" + ], + "motorOutput": [ + "MA0066" + ], + "stopperOutput": [ + "MB3436", + "MB3451" + ] + }, + "signalCount": 11 + }, + { + "unit": "M4010", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0403", + "pos": [ + 359609.5, + 743769.1 + ], + "io": { + "sensorInSep": [ + "BG3391" + ], + "sensorCarrInPos": [ + "BG3392" + ], + "sensorFinger": [ + "BG3393" + ], + "sensorJam": [ + "BG3423" + ], + "sensorConvFull": [ + "BG3425" + ], + "motorOutput": [ + "MA0074" + ], + "stopperOutput": [ + "MB3391" + ] + }, + "signalCount": 7 + }, + { + "unit": "M4011", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0401", + "pos": [ + 360632.7, + 750259.0 + ], + "io": { + "sensorInSep": [ + "BG3250" + ], + "sensorFinger": [ + "BG3253" + ], + "sensorCarrInPos": [ + "BG3255" + ], + "sensorConvFull": [ + "BG3256" + ], + "sensorJam": [ + "BG3264" + ], + "motorOutput": [ + "MA0072" + ], + "stopperOutput": [ + "MB3250" + ] + }, + "signalCount": 7 + }, + { + "unit": "M4503", + "unitKind": "CV", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0401", + "pos": [ + 380629.7, + 750474.8 + ], + "io": { + "sensorJam": [ + "BG3251" + ] + }, + "signalCount": 1 + } + ], + "areas": [ + { + "id": "UZ0401", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0402", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0403", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0409", + "kind": "safetyZone", + "members": [], + "cabinets": [] + } + ], + "unassignedSignals": [ + "BP0004", + "DI0005", + "DI0006", + "DI0013", + "DI0014", + "DI0015", + "DI0016", + "DI0021", + "DI0022", + "DI0023", + "DI0033", + "DI0034", + "DI0035", + "DI0036", + "DI0037", + "PF0000", + "PF0001", + "PF0002", + "PF0003", + "PF0004", + "PF0005", + "PF0006", + "PF0030", + "PF0031", + "PF0032", + "PF0033", + "PF3311", + "PF3371", + "PF3431", + "QA0610", + "QA0611", + "QA0612", + "QA0613", + "QA0660", + "QA0661", + "QA0662", + "QA0663", + "SF0000", + "SF0001", + "SF0002", + "SF0003", + "SF0400", + "SF0404", + "SF0471", + "SF0472", + "SF0475", + "SF0476" + ], + "todo": [ + "topology[] aus connect-Daten uebernommen — TRO-IDs den Einheiten (units[]) noch zuordnen", + "Timings, Priority, Release, customCode manuell pflegen" + ], + "topology": { + "format": "hmf-connect-v1", + "tros": [ + { + "id": "TRO400", + "fbType": "Vario", + "comment": "TRO 400 (Vario)", + "entries": [ + { + "jamArea": "JA4000_1", + "dbRef": "\"DB_JamArea4000\".stJam4000_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA4001_1", + "dbRef": "\"DB_JamArea4001\".stJam4001_1", + "to": "TRO401", + "kind": "finger" + } + ] + }, + { + "id": "TRO401", + "fbType": "Vario", + "comment": "TRO 401 (Vario)", + "entries": [ + { + "jamArea": "JA4001_1", + "dbRef": "\"DB_JamArea4001\".stJam4001_1", + "from": "TRO400", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA4001_2", + "dbRef": "\"DB_JamArea4001\".stJam4001_2", + "to": "TRO402", + "kind": "finger" + } + ] + }, + { + "id": "TRO402", + "fbType": "1Sep", + "comment": "TRO 402 (1Sep) (Vor Brandschutztor)", + "entries": [ + { + "jamArea": "JA4001_2", + "dbRef": "\"DB_JamArea4001\".stJam4001_2", + "from": "TRO401", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA4002_1", + "dbRef": "\"DB_JamArea4002\".stJam4002_1", + "to": "TRO403", + "kind": "normal" + } + ] + }, + { + "id": "TRO403", + "fbType": "Vario", + "comment": "TRO 403 (Vario)", + "entries": [ + { + "jamArea": "JA4002_1", + "dbRef": "\"DB_JamArea4002\".stJam4002_1", + "from": "TRO402", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4002_2", + "dbRef": "\"DB_JamArea4002\".stJam4002_2", + "to": "TRO404", + "kind": "finger" + } + ] + }, + { + "id": "TRO404", + "fbType": "1Sep", + "comment": "TRO 404 (1Sep)", + "entries": [ + { + "jamArea": "JA4002_2", + "dbRef": "\"DB_JamArea4002\".stJam4002_2", + "from": "TRO403", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA4003_8", + "dbRef": "\"DB_JamArea4003\".stJam4003_8", + "to": "TRO424", + "kind": "normal" + } + ] + }, + { + "id": "TRO405", + "fbType": "1Sep1Swi", + "comment": "TRO 405 (1Sep1Switch) + Scanner (BX4100) + Behangskontrolle", + "entries": [ + { + "jamArea": "JA4003_1", + "dbRef": "\"DB_JamArea4003\".stJam4003_1", + "from": "TRO424", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4003_2", + "dbRef": "\"DB_JamArea4003\".stJam4003_2", + "to": "TRO406", + "kind": "dir2" + } + ] + }, + { + "id": "TRO406", + "fbType": "1Sep", + "comment": "TRO 406 (1Sep) + Scanner (BX4101)", + "entries": [ + { + "jamArea": "JA4003_2", + "dbRef": "\"DB_JamArea4003\".stJam4003_2", + "from": "TRO405", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA4003_3", + "dbRef": "\"DB_JamArea4003\".stJam4003_3", + "to": "TRO407", + "kind": "normal" + } + ] + }, + { + "id": "TRO407", + "fbType": "1Sep1Swi", + "comment": "TRO 407 (1Sep1Switch) + Scanner (BX4102)", + "entries": [ + { + "jamArea": "JA4003_3", + "dbRef": "\"DB_JamArea4003\".stJam4003_3", + "from": "TRO406", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4003_4", + "dbRef": "\"DB_JamArea4003\".stJam4003_4", + "to": "TRO410", + "kind": "dir2" + }, + { + "jamArea": "JA4004_1", + "dbRef": "\"DB_JamArea4004\".stJam4004_1", + "to": "TRO408", + "kind": "normal" + } + ] + }, + { + "id": "TRO408", + "fbType": "Vario", + "comment": "TRO 408 (Vario)", + "entries": [ + { + "jamArea": "JA4004_1", + "dbRef": "\"DB_JamArea4004\".stJam4004_1", + "from": "TRO407", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4004_2", + "dbRef": "\"DB_JamArea4004\".stJam4004_2", + "to": "TRO421", + "kind": "finger" + } + ] + }, + { + "id": "TRO409", + "fbType": "1Sep", + "comment": "TRO 409 (1Sep)", + "entries": [], + "exits": [ + { + "jamArea": "JA4003_4", + "dbRef": "\"DB_JamArea4003\".stJam4003_4", + "to": "TRO410", + "kind": "normal" + } + ] + }, + { + "id": "TRO410", + "fbType": "1Sep1Swi", + "comment": "TRO 410 (1Sep1Switch) + Scanner (BX4104)", + "entries": [ + { + "jamArea": "JA4003_4", + "dbRef": "\"DB_JamArea4003\".stJam4003_4", + "from": "TRO407", + "kind": "dir2" + }, + { + "jamArea": "JA4003_4", + "dbRef": "\"DB_JamArea4003\".stJam4003_4", + "from": "TRO409", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4003_5", + "dbRef": "\"DB_JamArea4003\".stJam4003_5", + "to": "TRO413", + "kind": "dir2" + }, + { + "jamArea": "JA4006_1", + "dbRef": "\"DB_JamArea4006\".stJam4006_1", + "to": "TRO411", + "kind": "normal" + } + ] + }, + { + "id": "TRO411", + "fbType": "Vario", + "comment": "TRO 411 (Vario)", + "entries": [ + { + "jamArea": "JA4006_1", + "dbRef": "\"DB_JamArea4006\".stJam4006_1", + "from": "TRO410", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4006_2", + "dbRef": "\"DB_JamArea4006\".stJam4006_2", + "to": "TRO422", + "kind": "finger" + } + ] + }, + { + "id": "TRO412", + "fbType": "1Sep", + "comment": "TRO 412 (1Sep)", + "entries": [ + { + "jamArea": "JA4007_1", + "dbRef": "\"DB_JamArea4007\".stJam4007_1", + "from": "TRO422", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA4003_5", + "dbRef": "\"DB_JamArea4003\".stJam4003_5", + "to": "TRO413", + "kind": "normal" + } + ] + }, + { + "id": "TRO413", + "fbType": "1Sep1Swi", + "comment": "TRO 413(1Sep1Switch)+Scanner(BX4106)", + "entries": [ + { + "jamArea": "JA4003_5", + "dbRef": "\"DB_JamArea4003\".stJam4003_5", + "from": "TRO410", + "kind": "dir2" + }, + { + "jamArea": "JA4003_5", + "dbRef": "\"DB_JamArea4003\".stJam4003_5", + "from": "TRO412", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4003_6", + "dbRef": "\"DB_JamArea4003\".stJam4003_6", + "to": "TRO416", + "kind": "dir2" + }, + { + "jamArea": "JA4008_1", + "dbRef": "\"DB_JamArea4008\".stJam4008_1", + "to": "TRO414", + "kind": "normal" + } + ] + }, + { + "id": "TRO414", + "fbType": "Vario", + "comment": "TRO 414 (Vario)", + "entries": [ + { + "jamArea": "JA4008_1", + "dbRef": "\"DB_JamArea4008\".stJam4008_1", + "from": "TRO413", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4008_2", + "dbRef": "\"DB_JamArea4008\".stJam4008_2", + "to": "TRO423", + "kind": "finger" + } + ] + }, + { + "id": "TRO415", + "fbType": "1Sep", + "comment": "TRO 415 (1Sep)", + "entries": [ + { + "jamArea": "JA4009_1", + "dbRef": "\"DB_JamArea4009\".stJam4009_1", + "from": "TRO423", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA4003_6", + "dbRef": "\"DB_JamArea4003\".stJam4003_6", + "to": "TRO416", + "kind": "normal" + } + ] + }, + { + "id": "TRO416", + "fbType": "1Sep", + "comment": "TRO 416 (1Sep) + Beladeprüfung", + "entries": [ + { + "jamArea": "JA4003_6", + "dbRef": "\"DB_JamArea4003\".stJam4003_6", + "from": "TRO413", + "kind": "dir2" + }, + { + "jamArea": "JA4003_6", + "dbRef": "\"DB_JamArea4003\".stJam4003_6", + "from": "TRO415", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4003_7", + "dbRef": "\"DB_JamArea4003\".stJam4003_7", + "to": "TRO417", + "kind": "normal" + } + ] + }, + { + "id": "TRO417", + "fbType": "1Sep", + "comment": "TRO 417 (1Sep)", + "entries": [ + { + "jamArea": "JA4003_7", + "dbRef": "\"DB_JamArea4003\".stJam4003_7", + "from": "TRO416", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4003_8", + "dbRef": "\"DB_JamArea4003\".stJam4003_8", + "to": "TRO424", + "kind": "normal" + } + ] + }, + { + "id": "TRO418", + "fbType": "Vario", + "comment": "TRO 418 (Vario)", + "entries": [ + { + "jamArea": "JA4010_1", + "dbRef": "\"DB_JamArea4010\".stJam4010_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA4011_1", + "dbRef": "\"DB_JamArea4011\".stJam4011_1", + "to": "TRO420", + "kind": "finger" + } + ] + }, + { + "id": "TRO420", + "fbType": "Vario", + "comment": "TRO 420 (Vario)", + "entries": [ + { + "jamArea": "JA4011_1", + "dbRef": "\"DB_JamArea4011\".stJam4011_1", + "from": "TRO418", + "kind": "finger" + } + ], + "exits": [] + }, + { + "id": "TRO421", + "fbType": "Vario_workStation", + "comment": "TRO 421 (Vario)", + "entries": [ + { + "jamArea": "JA4004_2", + "dbRef": "\"DB_JamArea4004\".stJam4004_2", + "from": "TRO408", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA4005_1", + "dbRef": "\"DB_JamArea4005\".stJam4005_1", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO422", + "fbType": "Vario_workStation", + "comment": "TRO 422 (Vario)", + "entries": [ + { + "jamArea": "JA4006_2", + "dbRef": "\"DB_JamArea4006\".stJam4006_2", + "from": "TRO411", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA4007_1", + "dbRef": "\"DB_JamArea4007\".stJam4007_1", + "to": "TRO412", + "kind": "finger" + } + ] + }, + { + "id": "TRO423", + "fbType": "Vario_workStation", + "comment": "TRO 423 (Vario)", + "entries": [ + { + "jamArea": "JA4008_2", + "dbRef": "\"DB_JamArea4008\".stJam4008_2", + "from": "TRO414", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA4009_1", + "dbRef": "\"DB_JamArea4009\".stJam4009_1", + "to": "TRO415", + "kind": "finger" + } + ] + }, + { + "id": "TRO424", + "fbType": "1Sep", + "comment": "TRO 424 (1Sep) vor Behangskontrolle", + "entries": [ + { + "jamArea": "JA4003_8", + "dbRef": "\"DB_JamArea4003\".stJam4003_8", + "from": "TRO404", + "kind": "normal" + }, + { + "jamArea": "JA4003_8", + "dbRef": "\"DB_JamArea4003\".stJam4003_8", + "from": "TRO417", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA4003_1", + "dbRef": "\"DB_JamArea4003\".stJam4003_1", + "to": "TRO405", + "kind": "normal" + } + ] + } + ], + "connections": [ + { + "from": "TRO400", + "to": "TRO401", + "jamArea": "JA4001_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4001\".stJam4001_1" + }, + { + "from": "TRO401", + "to": "TRO402", + "jamArea": "JA4001_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4001\".stJam4001_2" + }, + { + "from": "TRO402", + "to": "TRO403", + "jamArea": "JA4002_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4002\".stJam4002_1" + }, + { + "from": "TRO403", + "to": "TRO404", + "jamArea": "JA4002_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4002\".stJam4002_2" + }, + { + "from": "TRO424", + "to": "TRO405", + "jamArea": "JA4003_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_1" + }, + { + "from": "TRO405", + "to": "TRO406", + "jamArea": "JA4003_2", + "kind": "dir2", + "dbRef": "\"DB_JamArea4003\".stJam4003_2" + }, + { + "from": "TRO406", + "to": "TRO407", + "jamArea": "JA4003_3", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_3" + }, + { + "from": "TRO407", + "to": "TRO410", + "jamArea": "JA4003_4", + "kind": "dir2", + "dbRef": "\"DB_JamArea4003\".stJam4003_4" + }, + { + "from": "TRO409", + "to": "TRO410", + "jamArea": "JA4003_4", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_4" + }, + { + "from": "TRO410", + "to": "TRO413", + "jamArea": "JA4003_5", + "kind": "dir2", + "dbRef": "\"DB_JamArea4003\".stJam4003_5" + }, + { + "from": "TRO412", + "to": "TRO413", + "jamArea": "JA4003_5", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_5" + }, + { + "from": "TRO413", + "to": "TRO416", + "jamArea": "JA4003_6", + "kind": "dir2", + "dbRef": "\"DB_JamArea4003\".stJam4003_6" + }, + { + "from": "TRO415", + "to": "TRO416", + "jamArea": "JA4003_6", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_6" + }, + { + "from": "TRO416", + "to": "TRO417", + "jamArea": "JA4003_7", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_7" + }, + { + "from": "TRO404", + "to": "TRO424", + "jamArea": "JA4003_8", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_8" + }, + { + "from": "TRO417", + "to": "TRO424", + "jamArea": "JA4003_8", + "kind": "normal", + "dbRef": "\"DB_JamArea4003\".stJam4003_8" + }, + { + "from": "TRO407", + "to": "TRO408", + "jamArea": "JA4004_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4004\".stJam4004_1" + }, + { + "from": "TRO408", + "to": "TRO421", + "jamArea": "JA4004_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4004\".stJam4004_2" + }, + { + "from": "TRO410", + "to": "TRO411", + "jamArea": "JA4006_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4006\".stJam4006_1" + }, + { + "from": "TRO411", + "to": "TRO422", + "jamArea": "JA4006_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4006\".stJam4006_2" + }, + { + "from": "TRO422", + "to": "TRO412", + "jamArea": "JA4007_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4007\".stJam4007_1" + }, + { + "from": "TRO413", + "to": "TRO414", + "jamArea": "JA4008_1", + "kind": "normal", + "dbRef": "\"DB_JamArea4008\".stJam4008_1" + }, + { + "from": "TRO414", + "to": "TRO423", + "jamArea": "JA4008_2", + "kind": "finger", + "dbRef": "\"DB_JamArea4008\".stJam4008_2" + }, + { + "from": "TRO423", + "to": "TRO415", + "jamArea": "JA4009_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4009\".stJam4009_1" + }, + { + "from": "TRO418", + "to": "TRO420", + "jamArea": "JA4011_1", + "kind": "finger", + "dbRef": "\"DB_JamArea4011\".stJam4011_1" + } + ], + "externals": [ + { + "node": "TRO400", + "direction": "in", + "jamArea": "JA4000_1", + "dbRef": "\"DB_JamArea4000\".stJam4000_1" + }, + { + "node": "TRO421", + "direction": "out", + "jamArea": "JA4005_1", + "dbRef": "\"DB_JamArea4005\".stJam4005_1" + }, + { + "node": "TRO418", + "direction": "in", + "jamArea": "JA4010_1", + "dbRef": "\"DB_JamArea4010\".stJam4010_1" + } + ] + } +} \ No newline at end of file diff --git a/results/skeleton_UH05.json b/results/skeleton_UH05.json new file mode 100644 index 0000000..9e24375 --- /dev/null +++ b/results/skeleton_UH05.json @@ -0,0 +1,3741 @@ +{ + "$schema": "hmf-layout-v1.schema.json", + "generatedBy": "create_skel.py", + "plc": { + "id": "UH05", + "configName": "=A01+UH05-KF00" + }, + "statistics": { + "tags": 243, + "sensors": 161, + "constants": 243, + "units": 16, + "areas": 10, + "unassignedSignals": 51, + "troNodes": 32, + "connections": 32, + "externals": 7 + }, + "sensors": [ + { + "id": "SF0000", + "constant": "cInSF0000", + "hwAddress": "%E000.0", + "comment": "DT Anlage Aus", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 147711.2 + ] + }, + { + "id": "SF0001", + "constant": "cInSF0001", + "hwAddress": "%E000.1", + "comment": "LDT Anlage Ein", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 147441.2 + ] + }, + { + "id": "SF0002", + "constant": "cInSF0002", + "hwAddress": "%E000.2", + "comment": "LDT Reset", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 147171.2 + ] + }, + { + "id": "SF0003", + "constant": "cInSF0003", + "hwAddress": "%E000.3", + "comment": "DT Lampentest", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 146901.2 + ] + }, + { + "id": "BP0004", + "constant": "cInBP0004", + "hwAddress": "%E000.4", + "comment": "Druckschalter Druckluft OK", + "role": null, + "unit": null, + "cabinet": "UH05", + "pos": [ + 216203.7, + 156730.0 + ] + }, + { + "id": "DI0005", + "constant": "cInDI0005", + "hwAddress": "%E000.5", + "comment": "Phasenausfall 400V", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 143966.1 + ] + }, + { + "id": "DI0006", + "constant": "cInDI0006", + "hwAddress": "%E000.6", + "comment": "Vorsicherung 400V UC Reserve", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 143696.1 + ] + }, + { + "id": "DI0012", + "constant": "cInDI0012", + "hwAddress": "%E001.2", + "comment": "Feedback Koppelrelais E-Stop-IF UH07 (QA0612/QA0613)", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "DI0013", + "constant": "cInDI0013", + "hwAddress": "%E001.3", + "comment": "Feedback Hauptschütze aktiv (QA0060 - QA0070)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 140779.5 + ] + }, + { + "id": "DI0014", + "constant": "cInDI0014", + "hwAddress": "%E001.4", + "comment": "Feedback Koppelrelais E-Stop-IF (QA0660/QA0661)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 139626.9 + ] + }, + { + "id": "DI0015", + "constant": "cInDI0015", + "hwAddress": "%E001.5", + "comment": "Feedback Koppelrelais E-Stop-IF", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 138076.8 + ] + }, + { + "id": "DI0016", + "constant": "cInDI0016", + "hwAddress": "%E001.6", + "comment": "Sicherungsautomatenfall", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 143393.9 + ] + }, + { + "id": "DI0021", + "constant": "cInDI0021", + "hwAddress": "%E002.1", + "comment": "Vorsicherung 24V OK (FC021)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 143102.6 + ] + }, + { + "id": "DI0022", + "constant": "cInDI0022", + "hwAddress": "%E002.2", + "comment": "Vorsicherung 24V OK (FC022)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 142832.6 + ] + }, + { + "id": "DI0023", + "constant": "cInDI0023", + "hwAddress": "%E002.3", + "comment": "Vorsicherung 24V OK (FC023)", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 142562.6 + ] + }, + { + "id": "DI0034", + "constant": "cInDI0034", + "hwAddress": "%E003.4", + "comment": "IF BMZ \"fire alarm\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 211056.3, + 134221.7 + ] + }, + { + "id": "DI0035", + "constant": "cInDI0035", + "hwAddress": "%E003.5", + "comment": "IF BST \"No fire alarm\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 142213.7 + ] + }, + { + "id": "DI0036", + "constant": "cInDI0036", + "hwAddress": "%E003.6", + "comment": "IF BST \"Non fault\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 141943.7 + ] + }, + { + "id": "DI0037", + "constant": "cInDI0037", + "hwAddress": "%E003.7", + "comment": "IF BST \"FPC opened\"", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 141673.7 + ] + }, + { + "id": "SF0041", + "constant": "cInSF0041", + "hwAddress": "%E004.1", + "comment": "Reset UZ0501", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 221223.2, + 146655.3 + ] + }, + { + "id": "SF0042", + "constant": "cInSF0042", + "hwAddress": "%E004.2", + "comment": "Freigabe UZ0502", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217133.1, + 159214.3 + ] + }, + { + "id": "SF0043", + "constant": "cInSF0043", + "hwAddress": "%E004.3", + "comment": "Reset UZ0502", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217133.1, + 158944.3 + ] + }, + { + "id": "SF0046", + "constant": "cInSF0046", + "hwAddress": "%E004.6", + "comment": "Freigabe UZ0504", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 226082.6, + 159218.6 + ] + }, + { + "id": "SF0047", + "constant": "cInSF0047", + "hwAddress": "%E004.7", + "comment": "Reset UZ0504", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 226082.6, + 158948.6 + ] + }, + { + "id": "SF0052", + "constant": "cInSF0052", + "hwAddress": "%E005.2", + "comment": "Freigeben UZ0506", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235226.2, + 159219.1 + ] + }, + { + "id": "SF0053", + "constant": "cInSF0053", + "hwAddress": "%E005.3", + "comment": "Reset UZ0506", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235226.2, + 158949.1 + ] + }, + { + "id": "SF0055", + "constant": "cInSF0055", + "hwAddress": "%E005.5", + "comment": "Reset UZ0507", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 243225.3, + 150080.4 + ] + }, + { + "id": "SF0056", + "constant": "cInSF0056", + "hwAddress": "%E005.6", + "comment": "Freigabe UZ0501", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "FC0060", + "constant": "cInFC0060", + "hwAddress": "%E006.0", + "comment": "MSS ausgelöst FC0060", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 210934.6, + 136263.4 + ] + }, + { + "id": "FC0061", + "constant": "cInFC0061", + "hwAddress": "%E006.1", + "comment": "MSS ausgelöst FC0061", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 210934.6, + 135993.4 + ] + }, + { + "id": "FC0062", + "constant": "cInFC0062", + "hwAddress": "%E006.2", + "comment": "MSS ausgelöst FC0062", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 210934.6, + 135723.4 + ] + }, + { + "id": "FC0063", + "constant": "cInFC0063", + "hwAddress": "%E006.3", + "comment": "MSS ausgelöst FC0063", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 210934.6, + 135467.3 + ] + }, + { + "id": "FC0064", + "constant": "cInFC0064", + "hwAddress": "%E006.4", + "comment": "MSS ausgelöst FC0064", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 210934.6, + 135197.3 + ] + }, + { + "id": "FC0065", + "constant": "cInFC0065", + "hwAddress": "%E006.5", + "comment": "MSS ausgelöst FC0065", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 213544.5, + 136277.3 + ] + }, + { + "id": "FC0066", + "constant": "cInFC0066", + "hwAddress": "%E006.6", + "comment": "MSS ausgelöst FC0066", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 213544.5, + 136007.3 + ] + }, + { + "id": "FC0067", + "constant": "cInFC0067", + "hwAddress": "%E006.7", + "comment": "MSS ausgelöst FC0067", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 213544.5, + 135737.3 + ] + }, + { + "id": "FC0070", + "constant": "cInFC0070", + "hwAddress": "%E007.0", + "comment": "MSS ausgelöst FC0070", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": [ + 213544.5, + 135467.3 + ] + }, + { + "id": "FC0071", + "constant": "cInFC0071", + "hwAddress": "%E007.1", + "comment": "MSS ausgelöst FC0071", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "FC0072", + "constant": "cInFC0072", + "hwAddress": "%E007.2", + "comment": "MSS ausgelöst FC0072", + "role": "motorProtection", + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "SF0400", + "constant": "cInSF0400", + "hwAddress": "%E040.0", + "comment": "Not Halt Kanal 1 UH05", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 145281.2 + ] + }, + { + "id": "SF0401", + "constant": "cInSF0401", + "hwAddress": "%E040.1", + "comment": "Not Halt Kanal 1 UZ0501", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 221223.2, + 146355.1 + ] + }, + { + "id": "SF0402", + "constant": "cInSF0402", + "hwAddress": "%E040.2", + "comment": "Not Halt Kanal 1 UZ0502", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217133.1, + 158644.1 + ] + }, + { + "id": "SF0404", + "constant": "cInSF0404", + "hwAddress": "%E040.4", + "comment": "Not Halt Kanal 2 UH05", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 145011.2 + ] + }, + { + "id": "SF0405", + "constant": "cInSF0405", + "hwAddress": "%E040.5", + "comment": "Not Halt Kanal 2 UZ0501", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 221223.2, + 146085.1 + ] + }, + { + "id": "SF0406", + "constant": "cInSF0406", + "hwAddress": "%E040.6", + "comment": "Not Halt Kanal 2 UZ0502", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 217133.1, + 158374.1 + ] + }, + { + "id": "SF0470", + "constant": "cInSF0470", + "hwAddress": "%E047.0", + "comment": "Not Halt Kanal 1 UZ0504", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 226082.6, + 158648.4 + ] + }, + { + "id": "SF0472", + "constant": "cInSF0472", + "hwAddress": "%E047.2", + "comment": "Not Halt Kanal 1 UZ0506", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235226.2, + 158648.9 + ] + }, + { + "id": "SF0473", + "constant": "cInSF0473", + "hwAddress": "%E047.3", + "comment": "Not Halt Kanal 1 UZ0507", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 243225.3, + 149780.2 + ] + }, + { + "id": "SF0474", + "constant": "cInSF0474", + "hwAddress": "%E047.4", + "comment": "Not Halt Kanal 2 UZ0504", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 226082.6, + 158378.4 + ] + }, + { + "id": "SF0476", + "constant": "cInSF0476", + "hwAddress": "%E047.6", + "comment": "Not Halt Kanal 2 UZ0506", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 235226.2, + 158378.9 + ] + }, + { + "id": "SF0477", + "constant": "cInSF0477", + "hwAddress": "%E047.7", + "comment": "Not Halt Kanal 2 UZ0507", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 243206.9, + 149524.0 + ] + }, + { + "id": "SF0541", + "constant": "cInSF0541", + "hwAddress": "%E054.1", + "comment": "Not Halt Schnittstelle von UH02 CH1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210945.7, + 139049.3 + ] + }, + { + "id": "SF0542", + "constant": "cInSF0542", + "hwAddress": "%E054.2", + "comment": "Not Halt Schnittstelle von System Fortna C, CH1", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210945.7, + 138779.3 + ] + }, + { + "id": "SF0543", + "constant": "cInSF0543", + "hwAddress": "%E054.3", + "comment": "Not Halt Schnittstelle von UH07 CH1", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "SF0545", + "constant": "cInSF0545", + "hwAddress": "%E054.5", + "comment": "Not Halt Schnittstelle von UH02 CH2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 137536.8 + ] + }, + { + "id": "SF0546", + "constant": "cInSF0546", + "hwAddress": "%E054.6", + "comment": "Not Halt Schnittstelle von System Fortna C, CH2", + "role": null, + "unit": null, + "cabinet": null, + "pos": [ + 210948.8, + 137266.8 + ] + }, + { + "id": "SF0547", + "constant": "cInSF0547", + "hwAddress": "%E054.7", + "comment": "Not Halt Schnittstelle von UH07 CH2", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG3240", + "constant": "cInBG3240", + "hwAddress": "%E324.0", + "comment": "in Separator (ILS KR-M5002)", + "role": "sensorInSep", + "unit": "M5002", + "cabinet": "UC0501", + "pos": [ + 216938.3, + 150042.3 + ] + }, + { + "id": "BG3241", + "constant": "cInBG3241", + "hwAddress": "%E324.1", + "comment": "Stausensor (ILS KR-M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0501", + "pos": [ + 216292.0, + 151900.4 + ] + }, + { + "id": "BG3242", + "constant": "cInBG3242", + "hwAddress": "%E324.2", + "comment": "in Separator (ILS KR-M5002)", + "role": "sensorInSep", + "unit": "M5002", + "cabinet": "UC0501", + "pos": [ + 217034.5, + 151893.5 + ] + }, + { + "id": "BG3243", + "constant": "cInBG3243", + "hwAddress": "%E324.3", + "comment": "Staumelder, Einfahrt (ILS-CV-M5003)", + "role": "sensorJam", + "unit": "M5003", + "cabinet": "UC0501", + "pos": [ + 218683.8, + 152003.3 + ] + }, + { + "id": "BG3244", + "constant": "cInBG3244", + "hwAddress": "%E324.4", + "comment": "Staumelder, Einfahrt (ILS-CV M5003) WS1.1", + "role": "sensorCarrInPos", + "unit": "M5003", + "cabinet": "UC0501", + "pos": [ + 218690.3, + 154332.0 + ] + }, + { + "id": "BG3245", + "constant": "cInBG3245", + "hwAddress": "%E324.5", + "comment": "in Separator 1 (ILS-CV M5003) WS1.1", + "role": "sensorInSep", + "unit": "M5003", + "cabinet": "UC0501", + "pos": [ + 218685.4, + 153532.6 + ] + }, + { + "id": "BG3246", + "constant": "cInBG3246", + "hwAddress": "%E324.6", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M5003) WS1.1", + "role": "sensorFinger", + "unit": "M5003", + "cabinet": "UC0501", + "pos": [ + 218697.2, + 154643.9 + ] + }, + { + "id": "BG3247", + "constant": "cInBG3247", + "hwAddress": "%E324.7", + "comment": "Sensor Förderer voll (ILS-CV M5003) WS1.1", + "role": "sensorConvFull", + "unit": "M5003", + "cabinet": "UC0501", + "pos": [ + 219452.6, + 157546.1 + ] + }, + { + "id": "BG3250", + "constant": "cInBG3250", + "hwAddress": "%E325.0", + "comment": "Stausensor (ILS-CV M5003) WS1.1", + "role": "sensorJam", + "unit": "M5003", + "cabinet": "UC0501", + "pos": [ + 219452.6, + 156994.2 + ] + }, + { + "id": "BG3251", + "constant": "cInBG3251", + "hwAddress": "%E325.1", + "comment": "in Separator 2 (ILS-CV M5004) WS1.1", + "role": "sensorInSep", + "unit": "M5004", + "cabinet": "UC0501", + "pos": [ + 219452.6, + 156401.3 + ] + }, + { + "id": "BG3252", + "constant": "cInBG3252", + "hwAddress": "%E325.2", + "comment": "Staumelder, Einfahrt (ILS-CV M5004) WS1.1", + "role": "sensorJam", + "unit": "M5004", + "cabinet": "UC0501", + "pos": [ + 219457.2, + 156108.3 + ] + }, + { + "id": "BG3253", + "constant": "cInBG3253", + "hwAddress": "%E325.3", + "comment": "in Separator 3 (ILS-CV M5004) WS1.1", + "role": "sensorInSep", + "unit": "M5004", + "cabinet": "UC0501", + "pos": [ + 219452.6, + 155555.6 + ] + }, + { + "id": "BG3254", + "constant": "cInBG3254", + "hwAddress": "%E325.4", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M5004) WS1.1", + "role": "sensorFinger", + "unit": "M5004", + "cabinet": "UC0501", + "pos": [ + 219477.1, + 154858.7 + ] + }, + { + "id": "BG3255", + "constant": "cInBG3255", + "hwAddress": "%E325.5", + "comment": "MT in Position (ILS-CV M5004) WS1.1", + "role": "sensorCarrInPos", + "unit": "M5004", + "cabinet": "UC0501", + "pos": [ + 219465.2, + 154588.1 + ] + }, + { + "id": "BG3256", + "constant": "cInBG3256", + "hwAddress": "%E325.6", + "comment": "Sensor Förderer voll (ILS-CV M5004) WS1.1", + "role": "sensorConvFull", + "unit": "M5004", + "cabinet": "UC0501", + "pos": [ + 220121.9, + 153706.0 + ] + }, + { + "id": "BG3257", + "constant": "cInBG3257", + "hwAddress": "%E325.7", + "comment": "in Separator 4 (ILS-CV M5004) WS1.1", + "role": "sensorInSep", + "unit": "M5004", + "cabinet": "UC0501", + "pos": [ + 220121.6, + 152757.5 + ] + }, + { + "id": "BG3260", + "constant": "cInBG3260", + "hwAddress": "%E326.0", + "comment": "Staumelder, Einfahrt (ILS-KR-M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0501", + "pos": [ + 220148.3, + 151237.7 + ] + }, + { + "id": "BG3261", + "constant": "cInBG3261", + "hwAddress": "%E326.1", + "comment": "Stausensor (ILS KR-M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0501", + "pos": [ + 218680.6, + 151246.3 + ] + }, + { + "id": "BG3262", + "constant": "cInBG3262", + "hwAddress": "%E326.2", + "comment": "Stausensor 1 (ILS-CV M5004) WS1.1", + "role": "sensorJam", + "unit": "M5004", + "cabinet": null, + "pos": null + }, + { + "id": "BG3300", + "constant": "cInBG3300", + "hwAddress": "%E330.0", + "comment": "Sensor Förderer voll (ILS CV-M5000)", + "role": "sensorConvFull", + "unit": "M5000", + "cabinet": "UC0502", + "pos": [ + 225961.4, + 149696.4 + ] + }, + { + "id": "BG3301", + "constant": "cInBG3301", + "hwAddress": "%E330.1", + "comment": "in Separator (ILS CV-M5000)", + "role": "sensorInSep", + "unit": "M5000", + "cabinet": "UC0502", + "pos": [ + 224376.1, + 149841.1 + ] + }, + { + "id": "BG3302", + "constant": "cInBG3302", + "hwAddress": "%E330.2", + "comment": "Stausensor (ILS KR-M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0502", + "pos": [ + 222261.4, + 150904.0 + ] + }, + { + "id": "BG3303", + "constant": "cInBG3303", + "hwAddress": "%E330.3", + "comment": "Sensor Förderer voll (ILS CV-M5001)", + "role": "sensorConvFull", + "unit": "M5001", + "cabinet": "UC0502", + "pos": [ + 224879.8, + 148296.3 + ] + }, + { + "id": "BG3304", + "constant": "cInBG3304", + "hwAddress": "%E330.4", + "comment": "in Separator (ILS CV-M5001)", + "role": "sensorInSep", + "unit": "M5001", + "cabinet": "UC0502", + "pos": [ + 222532.5, + 148777.6 + ] + }, + { + "id": "BG3305", + "constant": "cInBG3305", + "hwAddress": "%E330.5", + "comment": "Stausensor (ILS CV-M5001)", + "role": "sensorJam", + "unit": "M5001", + "cabinet": "UC0502", + "pos": [ + 220591.3, + 150883.9 + ] + }, + { + "id": "BG3306", + "constant": "cInBG3306", + "hwAddress": "%E330.6", + "comment": "in Separator (ILS KR-M5002)", + "role": "sensorInSep", + "unit": "M5002", + "cabinet": "UC0502", + "pos": [ + 226319.0, + 150167.2 + ] + }, + { + "id": "BG3307", + "constant": "cInBG3307", + "hwAddress": "%E330.7", + "comment": "in Separator (ILS CV-M5002)", + "role": "sensorInSep", + "unit": "M5002", + "cabinet": "UC0502", + "pos": [ + 224520.7, + 150901.3 + ] + }, + { + "id": "BG3310", + "constant": "cInBG3310", + "hwAddress": "%E331.0", + "comment": "Stausensor (ILS KR-M5000)", + "role": "sensorJam", + "unit": "M5000", + "cabinet": "UC0502", + "pos": [ + 223742.2, + 150901.3 + ] + }, + { + "id": "BG3311", + "constant": "cInBG3311", + "hwAddress": "%E331.1", + "comment": "Stausensor 1 (ILS CV-M5000)", + "role": "sensorJam", + "unit": "M5000", + "cabinet": null, + "pos": null + }, + { + "id": "BG3312", + "constant": "cInBG3312", + "hwAddress": "%E331.2", + "comment": "in Separator(ILS-KR-M5002)", + "role": "sensorInSep", + "unit": "M5002", + "cabinet": "UC0502", + "pos": [ + 221061.3, + 152212.8 + ] + }, + { + "id": "BG3313", + "constant": "cInBG3313", + "hwAddress": "%E331.3", + "comment": "Staumelder, Einfahrt (ILS-CV M5005)", + "role": "sensorJam", + "unit": "M5005", + "cabinet": "UC0502", + "pos": [ + 222265.9, + 151995.4 + ] + }, + { + "id": "BG3314", + "constant": "cInBG3314", + "hwAddress": "%E331.4", + "comment": "in Separator (ILS-CV M5005) WS 1.0", + "role": "sensorInSep", + "unit": "M5005", + "cabinet": "UC0502", + "pos": [ + 221057.7, + 154411.3 + ] + }, + { + "id": "BG3315", + "constant": "cInBG3315", + "hwAddress": "%E331.5", + "comment": "Staumelder, Einfahrt (ILS-CV M5005) WS 1.0", + "role": "sensorJam", + "unit": "M5005", + "cabinet": "UC0502", + "pos": [ + 221062.2, + 154968.4 + ] + }, + { + "id": "BG3316", + "constant": "cInBG3316", + "hwAddress": "%E331.6", + "comment": "in Separator 3 (ILS-CV M5005) WS 1.0", + "role": "sensorInSep", + "unit": "M5005", + "cabinet": "UC0502", + "pos": [ + 221057.7, + 155285.6 + ] + }, + { + "id": "BG3317", + "constant": "cInBG3317", + "hwAddress": "%E331.7", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M5005) WS 1.0", + "role": "sensorFinger", + "unit": "M5005", + "cabinet": "UC0502", + "pos": [ + 221074.1, + 156205.8 + ] + }, + { + "id": "BG3320", + "constant": "cInBG3320", + "hwAddress": "%E332.0", + "comment": "MT in Position (ILS-CV M5005) WS 1.0", + "role": "sensorCarrInPos", + "unit": "M5005", + "cabinet": "UC0502", + "pos": [ + 221062.2, + 156512.8 + ] + }, + { + "id": "BG3321", + "constant": "cInBG3321", + "hwAddress": "%E332.1", + "comment": "Sensor Förderer voll (ILS-CV M5005) WS 1.0", + "role": "sensorConvFull", + "unit": "M5005", + "cabinet": "UC0502", + "pos": [ + 223630.3, + 153596.9 + ] + }, + { + "id": "BG3322", + "constant": "cInBG3322", + "hwAddress": "%E332.2", + "comment": "in Separator (ILS-CV M5005) WS 1.0", + "role": "sensorInSep", + "unit": "M5005", + "cabinet": "UC0502", + "pos": [ + 223630.3, + 152587.2 + ] + }, + { + "id": "BG3323", + "constant": "cInBG3323", + "hwAddress": "%E332.3", + "comment": "Staumelder, Einfahrt (ILS-KR M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0502", + "pos": [ + 223919.9, + 151725.0 + ] + }, + { + "id": "BG3324", + "constant": "cInBG3324", + "hwAddress": "%E332.4", + "comment": "Stausensor (ILS KR-M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0502", + "pos": [ + 222261.4, + 151209.9 + ] + }, + { + "id": "BG3325", + "constant": "cInBG3325", + "hwAddress": "%E332.5", + "comment": "Stausensor 1 (ILS CV-M5001)", + "role": "sensorJam", + "unit": "M5001", + "cabinet": null, + "pos": null + }, + { + "id": "BG3326", + "constant": "cInBG3326", + "hwAddress": "%E332.6", + "comment": "Stausensor (ILS-CV M5005) WS 1.0", + "role": "sensorJam", + "unit": "M5005", + "cabinet": null, + "pos": null + }, + { + "id": "BG3327", + "constant": "cInBG3327", + "hwAddress": "%E332.7", + "comment": "Teil auf MT (Sep 5MB3307)", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG3330", + "constant": "cInBG3330", + "hwAddress": "%E333.0", + "comment": "in Separator (ILS-CV M0510)", + "role": "sensorInSep", + "unit": "M0510", + "cabinet": "UC0502", + "pos": [ + 243203.2, + 302710.2 + ] + }, + { + "id": "BG3331", + "constant": "cInBG3331", + "hwAddress": "%E333.1", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M5000_A)", + "role": "sensorFinger", + "unit": "M5000_A", + "cabinet": "UC0502", + "pos": [ + 243205.9, + 303316.4 + ] + }, + { + "id": "BG3332", + "constant": "cInBG3332", + "hwAddress": "%E333.2", + "comment": "MT in Position (ILS-CV M5000_A)", + "role": "sensorCarrInPos", + "unit": "M5000_A", + "cabinet": "UC0502", + "pos": [ + 243203.2, + 303583.2 + ] + }, + { + "id": "BG3333", + "constant": "cInBG3333", + "hwAddress": "%E333.3", + "comment": "in Separator (ILS-CV M5001_A)", + "role": "sensorInSep", + "unit": "M5001_A", + "cabinet": "UC0502", + "pos": [ + 241245.6, + 302055.1 + ] + }, + { + "id": "BG3334", + "constant": "cInBG3334", + "hwAddress": "%E333.4", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M5001_A)", + "role": "sensorFinger", + "unit": "M5001_A", + "cabinet": "UC0502", + "pos": [ + 241248.3, + 302674.7 + ] + }, + { + "id": "BG3335", + "constant": "cInBG3335", + "hwAddress": "%E333.5", + "comment": "MT in Position (ILS-CV M5001_A)", + "role": "sensorCarrInPos", + "unit": "M5001_A", + "cabinet": "UC0502", + "pos": [ + 241245.6, + 302941.3 + ] + }, + { + "id": "BG3360", + "constant": "cInBG3360", + "hwAddress": "%E336.0", + "comment": "in Separator(ILS-KR-M5002)", + "role": "sensorInSep", + "unit": "M5002", + "cabinet": "UC0503", + "pos": [ + 225042.0, + 152190.6 + ] + }, + { + "id": "BG3361", + "constant": "cInBG3361", + "hwAddress": "%E336.1", + "comment": "Staumelder, Einfahrt (ILS-CV M5006)", + "role": "sensorJam", + "unit": "M5006", + "cabinet": "UC0503", + "pos": [ + 226560.7, + 151995.4 + ] + }, + { + "id": "BG3362", + "constant": "cInBG3362", + "hwAddress": "%E336.2", + "comment": "in Separator (ILS-CV M5006) WS 2.0", + "role": "sensorInSep", + "unit": "M5006", + "cabinet": "UC0503", + "pos": [ + 225298.5, + 154773.6 + ] + }, + { + "id": "BG3363", + "constant": "cInBG3363", + "hwAddress": "%E336.3", + "comment": "Staumelder, Einfahrt (ILS-CV M5006) WS 2.0", + "role": "sensorJam", + "unit": "M5006", + "cabinet": "UC0503", + "pos": [ + 225303.1, + 155330.7 + ] + }, + { + "id": "BG3364", + "constant": "cInBG3364", + "hwAddress": "%E336.4", + "comment": "in Separator 3 (ILS-CV M5006) WS 2.0", + "role": "sensorInSep", + "unit": "M5006", + "cabinet": "UC0503", + "pos": [ + 225298.5, + 155647.9 + ] + }, + { + "id": "BG3365", + "constant": "cInBG3365", + "hwAddress": "%E336.5", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M5006) WS 2.0", + "role": "sensorFinger", + "unit": "M5006", + "cabinet": "UC0503", + "pos": [ + 225314.9, + 156315.9 + ] + }, + { + "id": "BG3366", + "constant": "cInBG3366", + "hwAddress": "%E336.6", + "comment": "MT in Position (ILS-CV M5006) WS 2.0", + "role": "sensorCarrInPos", + "unit": "M5006", + "cabinet": "UC0503", + "pos": [ + 225303.1, + 156585.4 + ] + }, + { + "id": "BG3367", + "constant": "cInBG3367", + "hwAddress": "%E336.7", + "comment": "Sensor Förderer voll (ILS-CV M5006) WS 2.0", + "role": "sensorConvFull", + "unit": "M5006", + "cabinet": "UC0503", + "pos": [ + 227659.5, + 153310.7 + ] + }, + { + "id": "BG3370", + "constant": "cInBG3370", + "hwAddress": "%E337.0", + "comment": "in Separator (ILS-CV M5006) WS 2.0", + "role": "sensorInSep", + "unit": "M5006", + "cabinet": "UC0503", + "pos": [ + 227659.5, + 152272.0 + ] + }, + { + "id": "BG3371", + "constant": "cInBG3371", + "hwAddress": "%E337.1", + "comment": "Staumelder, Einfahrt (ILS-KR M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0503", + "pos": [ + 227664.1, + 151954.8 + ] + }, + { + "id": "BG3372", + "constant": "cInBG3372", + "hwAddress": "%E337.2", + "comment": "in Separator(ILS-KR-M0500)", + "role": "sensorInSep", + "unit": "M0500", + "cabinet": "UC0503", + "pos": [ + 229602.9, + 152190.6 + ] + }, + { + "id": "BG3373", + "constant": "cInBG3373", + "hwAddress": "%E337.3", + "comment": "Staumelder, Einfahrt (ILS-CV M5007", + "role": "sensorJam", + "unit": "M5007", + "cabinet": "UC0503", + "pos": [ + 230839.8, + 151995.4 + ] + }, + { + "id": "BG3374", + "constant": "cInBG3374", + "hwAddress": "%E337.4", + "comment": "in Separator (ILS-CV M5007) WS 3.0", + "role": "sensorInSep", + "unit": "M5007", + "cabinet": "UC0503", + "pos": [ + 229607.8, + 154786.8 + ] + }, + { + "id": "BG3375", + "constant": "cInBG3375", + "hwAddress": "%E337.5", + "comment": "Staumelder, Einfahrt (ILS-CV M5007) WS 3.0", + "role": "sensorJam", + "unit": "M5007", + "cabinet": "UC0503", + "pos": [ + 229612.4, + 155343.9 + ] + }, + { + "id": "BG3376", + "constant": "cInBG3376", + "hwAddress": "%E337.6", + "comment": "in Separator 3 (ILS-CV M5007) WS 3.0", + "role": "sensorInSep", + "unit": "M5007", + "cabinet": "UC0503", + "pos": [ + 229607.8, + 155661.1 + ] + }, + { + "id": "BG3377", + "constant": "cInBG3377", + "hwAddress": "%E337.7", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M5007) WS 3.0", + "role": "sensorFinger", + "unit": "M5007", + "cabinet": "UC0503", + "pos": [ + 229624.2, + 156300.1 + ] + }, + { + "id": "BG3380", + "constant": "cInBG3380", + "hwAddress": "%E338.0", + "comment": "MT in Position (ILS-CV M5007) WS 3.0", + "role": "sensorCarrInPos", + "unit": "M5007", + "cabinet": "UC0503", + "pos": [ + 229612.4, + 156585.4 + ] + }, + { + "id": "BG3381", + "constant": "cInBG3381", + "hwAddress": "%E338.1", + "comment": "Sensor Förderer voll (ILS-CV M5007) WS 3.0", + "role": "sensorConvFull", + "unit": "M5007", + "cabinet": "UC0503", + "pos": [ + 232043.6, + 153356.9 + ] + }, + { + "id": "BG3382", + "constant": "cInBG3382", + "hwAddress": "%E338.2", + "comment": "in Separator (ILS-CV M5007) WS 3.0", + "role": "sensorInSep", + "unit": "M5007", + "cabinet": "UC0503", + "pos": [ + 232043.6, + 152272.0 + ] + }, + { + "id": "BG3383", + "constant": "cInBG3383", + "hwAddress": "%E338.3", + "comment": "Staumelder, Einfahrt (ILS-KR M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0503", + "pos": [ + 232048.2, + 151954.8 + ] + }, + { + "id": "BG3384", + "constant": "cInBG3384", + "hwAddress": "%E338.4", + "comment": "Stausensor (ILS KR-M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0503", + "pos": [ + 226560.5, + 151239.3 + ] + }, + { + "id": "BG3385", + "constant": "cInBG3385", + "hwAddress": "%E338.5", + "comment": "Stausensor (ILS KR-M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0503", + "pos": [ + 230839.7, + 151239.3 + ] + }, + { + "id": "BG3386", + "constant": "cInBG3386", + "hwAddress": "%E338.6", + "comment": "Stausensor (ILS-CV M5006) WS 2.0", + "role": "sensorJam", + "unit": "M5006", + "cabinet": null, + "pos": null + }, + { + "id": "BG3387", + "constant": "cInBG3387", + "hwAddress": "%E338.7", + "comment": "Stausensor (ILS-CV M5007) WS 3.0", + "role": "sensorJam", + "unit": "M5007", + "cabinet": null, + "pos": null + }, + { + "id": "BG3420", + "constant": "cInBG3420", + "hwAddress": "%E342.0", + "comment": "in Separator(ILS-KR-M5002)", + "role": "sensorInSep", + "unit": "M5002", + "cabinet": "UC0504", + "pos": [ + 233694.0, + 152131.9 + ] + }, + { + "id": "BG3421", + "constant": "cInBG3421", + "hwAddress": "%E342.1", + "comment": "Staumelder, Einfahrt (ILS-CV M5008)", + "role": "sensorJam", + "unit": "M5008", + "cabinet": "UC0504", + "pos": [ + 235410.7, + 151995.4 + ] + }, + { + "id": "BG3422", + "constant": "cInBG3422", + "hwAddress": "%E342.2", + "comment": "in Separator (ILS-CV M5008) WS 4.0", + "role": "sensorInSep", + "unit": "M5008", + "cabinet": "UC0504", + "pos": [ + 234162.4, + 154774.1 + ] + }, + { + "id": "BG3423", + "constant": "cInBG3423", + "hwAddress": "%E342.3", + "comment": "Staumelder, Einfahrt (ILS-CV M5008) WS 4.0", + "role": "sensorJam", + "unit": "M5008", + "cabinet": "UC0504", + "pos": [ + 234167.0, + 155331.3 + ] + }, + { + "id": "BG3424", + "constant": "cInBG3424", + "hwAddress": "%E342.4", + "comment": "in Separator (ILS-CV M5008) WS 4.0", + "role": "sensorInSep", + "unit": "M5008", + "cabinet": "UC0504", + "pos": [ + 234162.4, + 155648.4 + ] + }, + { + "id": "BG3425", + "constant": "cInBG3425", + "hwAddress": "%E342.5", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M5008) WS 4.0", + "role": "sensorFinger", + "unit": "M5008", + "cabinet": "UC0504", + "pos": [ + 234178.8, + 156315.9 + ] + }, + { + "id": "BG3426", + "constant": "cInBG3426", + "hwAddress": "%E342.6", + "comment": "MT in Position (ILS-CV M5008) WS 4.0", + "role": "sensorCarrInPos", + "unit": "M5008", + "cabinet": "UC0504", + "pos": [ + 234167.0, + 156585.4 + ] + }, + { + "id": "BG3427", + "constant": "cInBG3427", + "hwAddress": "%E342.7", + "comment": "Sensor Förderer voll (ILS-CV M5008) WS 4.0", + "role": "sensorConvFull", + "unit": "M5008", + "cabinet": "UC0504", + "pos": [ + 236615.2, + 153351.8 + ] + }, + { + "id": "BG3430", + "constant": "cInBG3430", + "hwAddress": "%E343.0", + "comment": "in Separator (ILS-CV M5008) WS 4.0", + "role": "sensorInSep", + "unit": "M5008", + "cabinet": "UC0504", + "pos": [ + 236615.2, + 152271.7 + ] + }, + { + "id": "BG3431", + "constant": "cInBG3431", + "hwAddress": "%E343.1", + "comment": "Staumelder, Einfahrt (ILS-KR M0500)", + "role": "sensorJam", + "unit": "M0500", + "cabinet": "UC0504", + "pos": [ + 236619.8, + 151954.5 + ] + }, + { + "id": "BG3432", + "constant": "cInBG3432", + "hwAddress": "%E343.2", + "comment": "in Separator(ILS-KR-M5002)", + "role": "sensorInSep", + "unit": "M5002", + "cabinet": "UC0504", + "pos": [ + 236300.3, + 150578.0 + ] + }, + { + "id": "BG3433", + "constant": "cInBG3433", + "hwAddress": "%E343.3", + "comment": "in Separator(ILS-KR-M5002)", + "role": "sensorInSep", + "unit": "M5002", + "cabinet": "UC0504", + "pos": [ + 238172.1, + 152032.3 + ] + }, + { + "id": "BG3434", + "constant": "cInBG3434", + "hwAddress": "%E343.4", + "comment": "Stausensor (ILS-KR M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0504", + "pos": [ + 239000.3, + 150368.2 + ] + }, + { + "id": "BG3435", + "constant": "cInBG3435", + "hwAddress": "%E343.5", + "comment": "Rad dreht (ILS-CV KR-M5002)", + "role": "sensorWheel", + "unit": "M5002", + "cabinet": "UC0504", + "pos": [ + 239738.2, + 150372.6 + ] + }, + { + "id": "BG3436", + "constant": "cInBG3436", + "hwAddress": "%E343.6", + "comment": "Staumelder, Einfahrt (ILS-CV M2111)", + "role": "sensorJam", + "unit": "M2111", + "cabinet": "UC0504", + "pos": [ + 239596.5, + 151994.1 + ] + }, + { + "id": "BG3437", + "constant": "cInBG3437", + "hwAddress": "%E343.7", + "comment": "Stausensor (ILS KR-M5002)", + "role": "sensorJam", + "unit": "M5002", + "cabinet": "UC0504", + "pos": [ + 235410.3, + 151239.3 + ] + }, + { + "id": "BG3440", + "constant": "cInBG3440", + "hwAddress": "%E344.0", + "comment": "Längenabfrage Grenze kurz (ILS-CV)", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG3441", + "constant": "cInBG3441", + "hwAddress": "%E344.1", + "comment": "Längenabfrage Grenze lang (ILS-CV)", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG3442", + "constant": "cInBG3442", + "hwAddress": "%E344.2", + "comment": "Längenabfrage Grenze zu lang (ILS-CV)", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG3443", + "constant": "cInBG3443", + "hwAddress": "%E344.3", + "comment": "Verlassensensor Längenmessung (ILS-CV)", + "role": null, + "unit": null, + "cabinet": null, + "pos": null + }, + { + "id": "BG3444", + "constant": "cInBG3444", + "hwAddress": "%E344.4", + "comment": "Stausensor (ILS-CV M5008) WS 4.0", + "role": "sensorJam", + "unit": "M5008", + "cabinet": null, + "pos": null + }, + { + "id": "BG3450", + "constant": "cInBG3450", + "hwAddress": "%E345.0", + "comment": "Sensor Förderer voll (ILS CV-M5000_A)", + "role": "sensorConvFull", + "unit": "M5000_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3451", + "constant": "cInBG3451", + "hwAddress": "%E345.1", + "comment": "Stausensor (ILS CV-M5000_A)", + "role": "sensorJam", + "unit": "M5000_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3452", + "constant": "cInBG3452", + "hwAddress": "%E345.2", + "comment": "in Separator (ILS CV-M5000_B)", + "role": "sensorInSep", + "unit": "M5000_B", + "cabinet": null, + "pos": null + }, + { + "id": "BG3453", + "constant": "cInBG3453", + "hwAddress": "%E345.3", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M5000_B)", + "role": "sensorFinger", + "unit": "M5000_B", + "cabinet": null, + "pos": null + }, + { + "id": "BG3454", + "constant": "cInBG3454", + "hwAddress": "%E345.4", + "comment": "MT in Position (ILS-CV M5000_B)", + "role": "sensorCarrInPos", + "unit": "M5000_B", + "cabinet": null, + "pos": null + }, + { + "id": "BG3455", + "constant": "cInBG3455", + "hwAddress": "%E345.5", + "comment": "Sensor Förderer voll (ILS CV-M5001_A)", + "role": "sensorConvFull", + "unit": "M5001_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3456", + "constant": "cInBG3456", + "hwAddress": "%E345.6", + "comment": "Stausensor (ILS CV-M5001_A)", + "role": "sensorJam", + "unit": "M5001_A", + "cabinet": null, + "pos": null + }, + { + "id": "BG3457", + "constant": "cInBG3457", + "hwAddress": "%E345.7", + "comment": "in Separator (ILS CV-M5001_B)", + "role": "sensorInSep", + "unit": "M5001_B", + "cabinet": null, + "pos": null + }, + { + "id": "BG3460", + "constant": "cInBG3460", + "hwAddress": "%E346.0", + "comment": "Abfrage Mitnehmerfinger in Position (ILS-CV M5001_B)", + "role": "sensorFinger", + "unit": "M5001_B", + "cabinet": null, + "pos": null + }, + { + "id": "BG3461", + "constant": "cInBG3461", + "hwAddress": "%E346.1", + "comment": "MT in Position (ILS-CV M5001_B)", + "role": "sensorCarrInPos", + "unit": "M5001_B", + "cabinet": null, + "pos": null + } + ], + "units": [ + { + "unit": "M0500", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC0503", + "pos": [ + 229602.9, + 152190.6 + ], + "io": { + "sensorInSep": [ + "BG3372" + ], + "sensorJam": [ + "BG3431" + ], + "stopperOutput": [ + "MB3372" + ] + }, + "signalCount": 3 + }, + { + "unit": "M0510", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC0502", + "pos": [ + 243203.2, + 302710.2 + ], + "io": { + "sensorInSep": [ + "BG3330" + ] + }, + "signalCount": 1 + }, + { + "unit": "M2111", + "unitKind": "CV", + "fbType": "UNBEKANNT", + "areas": [], + "cabinet": "UC0504", + "pos": [ + 239596.5, + 151994.1 + ], + "io": { + "sensorJam": [ + "BG3436" + ], + "switchOutput": [ + "MB3436" + ] + }, + "signalCount": 2 + }, + { + "unit": "M5000", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC0502", + "pos": [ + 225961.4, + 149696.4 + ], + "io": { + "sensorConvFull": [ + "BG3300" + ], + "sensorInSep": [ + "BG3301" + ], + "sensorJam": [ + "BG3310", + "BG3311" + ], + "stopperOutput": [ + "MB3301" + ] + }, + "signalCount": 5 + }, + { + "unit": "M5000_A", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0502", + "pos": [ + 243205.9, + 303316.4 + ], + "io": { + "sensorFinger": [ + "BG3331" + ], + "sensorCarrInPos": [ + "BG3332" + ], + "sensorConvFull": [ + "BG3450" + ], + "sensorJam": [ + "BG3451" + ], + "motorOutput": [ + "MA0071" + ], + "stopperOutput": [ + "MB3330" + ] + }, + "signalCount": 6 + }, + { + "unit": "M5000_B", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UH05", + "pos": [ + 225218.9, + 149684.5 + ], + "io": { + "sensorInSep": [ + "BG3452" + ], + "sensorFinger": [ + "BG3453" + ], + "sensorCarrInPos": [ + "BG3454" + ], + "motorOutput": [ + "MA0060" + ], + "stopperOutput": [ + "MB3452" + ] + }, + "signalCount": 5 + }, + { + "unit": "M5001", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC0502", + "pos": [ + 224879.8, + 148296.3 + ], + "io": { + "sensorConvFull": [ + "BG3303" + ], + "sensorInSep": [ + "BG3304" + ], + "sensorJam": [ + "BG3305", + "BG3325" + ], + "stopperOutput": [ + "MB3304" + ] + }, + "signalCount": 5 + }, + { + "unit": "M5001_A", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UC0502", + "pos": [ + 241245.6, + 302055.1 + ], + "io": { + "sensorInSep": [ + "BG3333" + ], + "sensorFinger": [ + "BG3334" + ], + "sensorCarrInPos": [ + "BG3335" + ], + "sensorConvFull": [ + "BG3455" + ], + "sensorJam": [ + "BG3456" + ], + "motorOutput": [ + "MA0072" + ], + "stopperOutput": [ + "MB3333" + ] + }, + "signalCount": 7 + }, + { + "unit": "M5001_B", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [], + "cabinet": "UH05", + "pos": [ + 224137.3, + 148284.3 + ], + "io": { + "sensorInSep": [ + "BG3457" + ], + "sensorFinger": [ + "BG3460" + ], + "sensorCarrInPos": [ + "BG3461" + ], + "motorOutput": [ + "MA0061" + ], + "stopperOutput": [ + "MB3457" + ] + }, + "signalCount": 5 + }, + { + "unit": "M5002", + "unitKind": "KR", + "fbType": "FB_ILS_MTRO_1Sep", + "areas": [], + "cabinet": "UC0501", + "pos": [ + 216938.3, + 150042.3 + ], + "io": { + "sensorInSep": [ + "BG3240", + "BG3242", + "BG3306", + "BG3307", + "BG3312", + "BG3360", + "BG3420", + "BG3432", + "BG3433" + ], + "sensorJam": [ + "BG3241", + "BG3260", + "BG3261", + "BG3302", + "BG3323", + "BG3324", + "BG3371", + "BG3383", + "BG3384", + "BG3385", + "BG3434", + "BG3437" + ], + "sensorWheel": [ + "BG3435" + ], + "motorOutput": [ + "MA0062" + ], + "stopperOutput": [ + "MB3240", + "MB3242", + "MB3306", + "MB3307", + "MB3312", + "MB3360", + "MB3420", + "MB3432", + "MB3433" + ] + }, + "signalCount": 32 + }, + { + "unit": "M5003", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "WS1.1", + "kind": "workStation" + } + ], + "cabinet": "UC0501", + "pos": [ + 218683.8, + 152003.3 + ], + "io": { + "sensorJam": [ + "BG3243", + "BG3250" + ], + "sensorCarrInPos": [ + "BG3244" + ], + "sensorInSep": [ + "BG3245" + ], + "sensorFinger": [ + "BG3246" + ], + "sensorConvFull": [ + "BG3247" + ], + "motorOutput": [ + "MA0063" + ], + "switchOutput": [ + "MB3243" + ], + "stopperOutput": [ + "MB3245" + ] + }, + "signalCount": 9 + }, + { + "unit": "M5004", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "WS1.1", + "kind": "workStation" + } + ], + "cabinet": "UC0501", + "pos": [ + 219452.6, + 156401.3 + ], + "io": { + "sensorInSep": [ + "BG3251", + "BG3253", + "BG3257" + ], + "sensorJam": [ + "BG3252", + "BG3262" + ], + "sensorFinger": [ + "BG3254" + ], + "sensorCarrInPos": [ + "BG3255" + ], + "sensorConvFull": [ + "BG3256" + ], + "motorOutput": [ + "MA0064" + ], + "stopperOutput": [ + "MB3251", + "MB3253", + "MB3257" + ] + }, + "signalCount": 12 + }, + { + "unit": "M5005", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "WS1.0", + "kind": "workStation" + } + ], + "cabinet": "UC0502", + "pos": [ + 222265.9, + 151995.4 + ], + "io": { + "sensorJam": [ + "BG3313", + "BG3315", + "BG3326" + ], + "sensorInSep": [ + "BG3314", + "BG3316", + "BG3322" + ], + "sensorFinger": [ + "BG3317" + ], + "sensorCarrInPos": [ + "BG3320" + ], + "sensorConvFull": [ + "BG3321" + ], + "motorOutput": [ + "MA0065" + ], + "switchOutput": [ + "MB3313" + ], + "stopperOutput": [ + "MB3314", + "MB3316", + "MB3322" + ] + }, + "signalCount": 14 + }, + { + "unit": "M5006", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "WS2.0", + "kind": "workStation" + } + ], + "cabinet": "UC0503", + "pos": [ + 226560.7, + 151995.4 + ], + "io": { + "sensorJam": [ + "BG3361", + "BG3363", + "BG3386" + ], + "sensorInSep": [ + "BG3362", + "BG3364", + "BG3370" + ], + "sensorFinger": [ + "BG3365" + ], + "sensorCarrInPos": [ + "BG3366" + ], + "sensorConvFull": [ + "BG3367" + ], + "motorOutput": [ + "MA0066" + ], + "switchOutput": [ + "MB3361" + ], + "stopperOutput": [ + "MB3362", + "MB3364", + "MB3370" + ] + }, + "signalCount": 14 + }, + { + "unit": "M5007", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "WS3.0", + "kind": "workStation" + } + ], + "cabinet": "UC0503", + "pos": [ + 230839.8, + 151995.4 + ], + "io": { + "sensorJam": [ + "BG3373", + "BG3375", + "BG3387" + ], + "sensorInSep": [ + "BG3374", + "BG3376", + "BG3382" + ], + "sensorFinger": [ + "BG3377" + ], + "sensorCarrInPos": [ + "BG3380" + ], + "sensorConvFull": [ + "BG3381" + ], + "motorOutput": [ + "MA0067" + ], + "switchOutput": [ + "MB3373" + ], + "stopperOutput": [ + "MB3374", + "MB3376", + "MB3382" + ] + }, + "signalCount": 14 + }, + { + "unit": "M5008", + "unitKind": "CV", + "fbType": "FB_ILS_MTRO_Vario", + "areas": [ + { + "id": "WS4.0", + "kind": "workStation" + } + ], + "cabinet": "UC0504", + "pos": [ + 235410.7, + 151995.4 + ], + "io": { + "sensorJam": [ + "BG3421", + "BG3423", + "BG3444" + ], + "sensorInSep": [ + "BG3422", + "BG3424", + "BG3430" + ], + "sensorFinger": [ + "BG3425" + ], + "sensorCarrInPos": [ + "BG3426" + ], + "sensorConvFull": [ + "BG3427" + ], + "motorOutput": [ + "MA0070" + ], + "switchOutput": [ + "MB3421" + ], + "stopperOutput": [ + "MB3422", + "MB3424", + "MB3430" + ] + }, + "signalCount": 14 + } + ], + "areas": [ + { + "id": "UZ0501", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0502", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0504", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0506", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "UZ0507", + "kind": "safetyZone", + "members": [], + "cabinets": [] + }, + { + "id": "WS1.0", + "kind": "workStation", + "members": [ + "M5005" + ], + "cabinets": [ + "UC0502", + "UH05" + ] + }, + { + "id": "WS1.1", + "kind": "workStation", + "members": [ + "M5003", + "M5004" + ], + "cabinets": [ + "UC0501", + "UH05" + ] + }, + { + "id": "WS2.0", + "kind": "workStation", + "members": [ + "M5006" + ], + "cabinets": [ + "UC0503", + "UH05" + ] + }, + { + "id": "WS3.0", + "kind": "workStation", + "members": [ + "M5007" + ], + "cabinets": [ + "UC0503", + "UH05" + ] + }, + { + "id": "WS4.0", + "kind": "workStation", + "members": [ + "M5008" + ], + "cabinets": [ + "UC0504", + "UH05" + ] + } + ], + "unassignedSignals": [ + "BG3327", + "BG3440", + "BG3441", + "BG3442", + "BG3443", + "BP0004", + "DI0005", + "DI0006", + "DI0012", + "DI0013", + "DI0014", + "DI0015", + "DI0016", + "DI0021", + "DI0022", + "DI0023", + "DI0034", + "DI0035", + "DI0036", + "DI0037", + "PF0000", + "PF0001", + "PF0002", + "PF0003", + "PF0004", + "PF0005", + "PF0006", + "PF0030", + "PF0031", + "PF0032", + "PF0033", + "QA0610", + "QA0611", + "QA0612", + "QA0613", + "QA0660", + "QA0661", + "QA0662", + "QA0663", + "SF0000", + "SF0001", + "SF0002", + "SF0003", + "SF0400", + "SF0404", + "SF0541", + "SF0542", + "SF0543", + "SF0545", + "SF0546", + "SF0547" + ], + "todo": [ + "topology[] aus connect-Daten uebernommen — TRO-IDs den Einheiten (units[]) noch zuordnen", + "Timings, Priority, Release, customCode manuell pflegen" + ], + "topology": { + "format": "hmf-connect-v1", + "tros": [ + { + "id": "TRO500", + "fbType": "Vario", + "comment": "TRO 500 (Vario) - Stand: Vorbereitet für Umbau!", + "entries": [ + { + "jamArea": "JA5001_1", + "dbRef": "\"DB_JamArea5001\".stJam5001_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA5001_2", + "dbRef": "\"DB_JamArea5001\".stJam5001_2", + "to": "TRO530", + "kind": "finger" + } + ] + }, + { + "id": "TRO501", + "fbType": "1Sep", + "comment": "TRO 501 (1Sep) + Scanner (BX5101)", + "entries": [ + { + "jamArea": "JA5001_3", + "dbRef": "\"DB_JamArea5001\".stJam5001_3", + "from": "TRO530", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA5002_1", + "dbRef": "\"DB_JamArea5002\".stJam5002_1", + "to": "TRO504", + "kind": "normal" + } + ] + }, + { + "id": "TRO502", + "fbType": "Vario", + "comment": "TRO 502 (Vario) - Stand: Vorbereitet für Umbau!", + "entries": [ + { + "jamArea": "JA5000_1", + "dbRef": "\"DB_JamArea5000\".stJam5000_1", + "from": "EXTERN", + "kind": "extern" + } + ], + "exits": [ + { + "jamArea": "JA5000_2", + "dbRef": "\"DB_JamArea5000\".stJam5000_2", + "to": "TRO531", + "kind": "finger" + } + ] + }, + { + "id": "TRO503", + "fbType": "1Sep", + "comment": "TRO 503 (1Sep)+ Scanner (BX5100)", + "entries": [ + { + "jamArea": "JA5000_3", + "dbRef": "\"DB_JamArea5000\".stJam5000_3", + "from": "TRO531", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA5002_1", + "dbRef": "\"DB_JamArea5002\".stJam5002_1", + "to": "TRO504", + "kind": "normal" + } + ] + }, + { + "id": "TRO504", + "fbType": "1Sep", + "comment": "TRO 504 (1Sep)", + "entries": [ + { + "jamArea": "JA5002_1", + "dbRef": "\"DB_JamArea5002\".stJam5002_1", + "from": "TRO501", + "kind": "normal" + }, + { + "jamArea": "JA5002_1", + "dbRef": "\"DB_JamArea5002\".stJam5002_1", + "from": "TRO503", + "kind": "normal" + }, + { + "jamArea": "JA5002_1", + "dbRef": "\"DB_JamArea5002\".stJam5002_1", + "from": "TRO529", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5002_2", + "dbRef": "\"DB_JamArea5002\".stJam5002_2", + "to": "TRO505", + "kind": "normal" + } + ] + }, + { + "id": "TRO505", + "fbType": "1Sep1Swi", + "comment": "TRO 505 (1Sep1Switch) + Scanner (BX5102)", + "entries": [ + { + "jamArea": "JA5002_2", + "dbRef": "\"DB_JamArea5002\".stJam5002_2", + "from": "TRO504", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5002_3", + "dbRef": "\"DB_JamArea5002\".stJam5002_3", + "to": "TRO510", + "kind": "dir2" + }, + { + "jamArea": "JA5003_1", + "dbRef": "\"DB_JamArea5003\".stJam5003_1", + "to": "TRO506", + "kind": "normal" + } + ] + }, + { + "id": "TRO506", + "fbType": "Vario", + "comment": "TRO 506 (Vario)", + "entries": [ + { + "jamArea": "JA5003_1", + "dbRef": "\"DB_JamArea5003\".stJam5003_1", + "from": "TRO505", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5003_2", + "dbRef": "\"DB_JamArea5003\".stJam5003_2", + "to": "TRO507", + "kind": "finger" + } + ] + }, + { + "id": "TRO507", + "fbType": "1Sep", + "comment": "TRO 507 (1Sep)", + "entries": [ + { + "jamArea": "JA5003_2", + "dbRef": "\"DB_JamArea5003\".stJam5003_2", + "from": "TRO506", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA5004_1", + "dbRef": "\"DB_JamArea5004\".stJam5004_1", + "to": "TRO508", + "kind": "normal" + } + ] + }, + { + "id": "TRO508", + "fbType": "Vario", + "comment": "TRO 508 (Vario)+Scanner(BX5103)", + "entries": [ + { + "jamArea": "JA5004_1", + "dbRef": "\"DB_JamArea5004\".stJam5004_1", + "from": "TRO507", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5004_2", + "dbRef": "\"DB_JamArea5004\".stJam5004_2", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO509", + "fbType": "1Sep", + "comment": "TRO 509 (1Sep)", + "entries": [], + "exits": [ + { + "jamArea": "JA5002_3", + "dbRef": "\"DB_JamArea5002\".stJam5002_3", + "to": "TRO510", + "kind": "normal" + } + ] + }, + { + "id": "TRO510", + "fbType": "1Sep1Swi", + "comment": "TRO 510 (1Sep1Switch) + Scanner (BX5104)", + "entries": [ + { + "jamArea": "JA5002_3", + "dbRef": "\"DB_JamArea5002\".stJam5002_3", + "from": "TRO505", + "kind": "dir2" + }, + { + "jamArea": "JA5002_3", + "dbRef": "\"DB_JamArea5002\".stJam5002_3", + "from": "TRO509", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5002_4", + "dbRef": "\"DB_JamArea5002\".stJam5002_4", + "to": "TRO514", + "kind": "dir2" + }, + { + "jamArea": "JA5005_1", + "dbRef": "\"DB_JamArea5005\".stJam5005_1", + "to": "TRO511", + "kind": "normal" + } + ] + }, + { + "id": "TRO511", + "fbType": "1Sep", + "comment": "TRO 511 (1Sep)", + "entries": [ + { + "jamArea": "JA5005_1", + "dbRef": "\"DB_JamArea5005\".stJam5005_1", + "from": "TRO510", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5005_2", + "dbRef": "\"DB_JamArea5005\".stJam5005_2", + "to": "TRO512", + "kind": "normal" + } + ] + }, + { + "id": "TRO512", + "fbType": "Vario", + "comment": "TRO 512 (Vario)+Scanner(BX5105)", + "entries": [ + { + "jamArea": "JA5005_2", + "dbRef": "\"DB_JamArea5005\".stJam5005_2", + "from": "TRO511", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5005_3", + "dbRef": "\"DB_JamArea5005\".stJam5005_3", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO513", + "fbType": "1Sep", + "comment": "TRO 513 (1Sep)", + "entries": [], + "exits": [ + { + "jamArea": "JA5002_4", + "dbRef": "\"DB_JamArea5002\".stJam5002_4", + "to": "TRO514", + "kind": "normal" + } + ] + }, + { + "id": "TRO514", + "fbType": "1Sep1Swi", + "comment": "TRO 514 (1Sep1Switch) + Scanner (BX5106)", + "entries": [ + { + "jamArea": "JA5002_4", + "dbRef": "\"DB_JamArea5002\".stJam5002_4", + "from": "TRO510", + "kind": "dir2" + }, + { + "jamArea": "JA5002_4", + "dbRef": "\"DB_JamArea5002\".stJam5002_4", + "from": "TRO513", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5002_5", + "dbRef": "\"DB_JamArea5002\".stJam5002_5", + "to": "TRO518", + "kind": "dir2" + }, + { + "jamArea": "JA5006_1", + "dbRef": "\"DB_JamArea5006\".stJam5006_1", + "to": "TRO515", + "kind": "normal" + } + ] + }, + { + "id": "TRO515", + "fbType": "1Sep", + "comment": "TRO 515 (1Sep)", + "entries": [ + { + "jamArea": "JA5006_1", + "dbRef": "\"DB_JamArea5006\".stJam5006_1", + "from": "TRO514", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5006_2", + "dbRef": "\"DB_JamArea5006\".stJam5006_2", + "to": "TRO516", + "kind": "normal" + } + ] + }, + { + "id": "TRO516", + "fbType": "Vario", + "comment": "TRO 516(Vario)+Scanner(BX5107)", + "entries": [ + { + "jamArea": "JA5006_2", + "dbRef": "\"DB_JamArea5006\".stJam5006_2", + "from": "TRO515", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5006_3", + "dbRef": "\"DB_JamArea5006\".stJam5006_3", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO517", + "fbType": "1Sep", + "comment": "TRO 517 (1Sep)", + "entries": [], + "exits": [ + { + "jamArea": "JA5002_5", + "dbRef": "\"DB_JamArea5002\".stJam5002_5", + "to": "TRO518", + "kind": "normal" + } + ] + }, + { + "id": "TRO518", + "fbType": "1Sep1Swi", + "comment": "TRO 518 (1Sep1Switch) + Scanner (BX5108)", + "entries": [ + { + "jamArea": "JA5002_5", + "dbRef": "\"DB_JamArea5002\".stJam5002_5", + "from": "TRO514", + "kind": "dir2" + }, + { + "jamArea": "JA5002_5", + "dbRef": "\"DB_JamArea5002\".stJam5002_5", + "from": "TRO517", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5002_6", + "dbRef": "\"DB_JamArea5002\".stJam5002_6", + "to": "TRO522", + "kind": "dir2" + }, + { + "jamArea": "JA5007_1", + "dbRef": "\"DB_JamArea5007\".stJam5007_1", + "to": "TRO519", + "kind": "normal" + } + ] + }, + { + "id": "TRO519", + "fbType": "1Sep", + "comment": "TRO 519 (1Sep)", + "entries": [ + { + "jamArea": "JA5007_1", + "dbRef": "\"DB_JamArea5007\".stJam5007_1", + "from": "TRO518", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5007_2", + "dbRef": "\"DB_JamArea5007\".stJam5007_2", + "to": "TRO520", + "kind": "normal" + } + ] + }, + { + "id": "TRO520", + "fbType": "Vario", + "comment": "TRO 520 (Vario)+Scanner(BX5109)", + "entries": [ + { + "jamArea": "JA5007_2", + "dbRef": "\"DB_JamArea5007\".stJam5007_2", + "from": "TRO519", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5007_3", + "dbRef": "\"DB_JamArea5007\".stJam5007_3", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO521", + "fbType": "1Sep", + "comment": "TRO 521(1Sep)", + "entries": [], + "exits": [ + { + "jamArea": "JA5002_6", + "dbRef": "\"DB_JamArea5002\".stJam5002_6", + "to": "TRO522", + "kind": "normal" + } + ] + }, + { + "id": "TRO522", + "fbType": "1Sep1Swi", + "comment": "TRO 522 (1Sep1Switch) + Scanner (BX5110)", + "entries": [ + { + "jamArea": "JA5002_6", + "dbRef": "\"DB_JamArea5002\".stJam5002_6", + "from": "TRO518", + "kind": "dir2" + }, + { + "jamArea": "JA5002_6", + "dbRef": "\"DB_JamArea5002\".stJam5002_6", + "from": "TRO521", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5002_7", + "dbRef": "\"DB_JamArea5002\".stJam5002_7", + "to": "TRO526", + "kind": "dir2" + }, + { + "jamArea": "JA5008_1", + "dbRef": "\"DB_JamArea5008\".stJam5008_1", + "to": "TRO523", + "kind": "normal" + } + ] + }, + { + "id": "TRO523", + "fbType": "1Sep", + "comment": "TRO 523 (1Sep)", + "entries": [ + { + "jamArea": "JA5008_1", + "dbRef": "\"DB_JamArea5008\".stJam5008_1", + "from": "TRO522", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5008_2", + "dbRef": "\"DB_JamArea5008\".stJam5008_2", + "to": "TRO524", + "kind": "normal" + } + ] + }, + { + "id": "TRO524", + "fbType": "Vario", + "comment": "TRO 524 (Vario)+Scanner(BX5231)", + "entries": [ + { + "jamArea": "JA5008_2", + "dbRef": "\"DB_JamArea5008\".stJam5008_2", + "from": "TRO523", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5008_3", + "dbRef": "\"DB_JamArea5008\".stJam5008_3", + "to": "EXTERN", + "kind": "extern" + } + ] + }, + { + "id": "TRO525", + "fbType": "1Sep", + "comment": "TRO 525(1Sep)", + "entries": [], + "exits": [ + { + "jamArea": "JA5002_7", + "dbRef": "\"DB_JamArea5002\".stJam5002_7", + "to": "TRO526", + "kind": "normal" + } + ] + }, + { + "id": "TRO526", + "fbType": "1Sep", + "comment": "TRO 526 (1Sep) + Scanner (BX5112)", + "entries": [ + { + "jamArea": "JA5002_7", + "dbRef": "\"DB_JamArea5002\".stJam5002_7", + "from": "TRO522", + "kind": "dir2" + }, + { + "jamArea": "JA5002_7", + "dbRef": "\"DB_JamArea5002\".stJam5002_7", + "from": "TRO525", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5002_8", + "dbRef": "\"DB_JamArea5002\".stJam5002_8", + "to": "TRO527", + "kind": "normal" + } + ] + }, + { + "id": "TRO527", + "fbType": "1Sep1Swi", + "comment": "TRO 527 (1Sep1Switch)", + "entries": [ + { + "jamArea": "JA5002_8", + "dbRef": "\"DB_JamArea5002\".stJam5002_8", + "from": "TRO526", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5002_9", + "dbRef": "\"DB_JamArea5002\".stJam5002_9", + "to": "TRO528", + "kind": "dir2" + } + ] + }, + { + "id": "TRO528", + "fbType": "1Sep", + "comment": "TRO 528 (1Sep)", + "entries": [ + { + "jamArea": "JA5002_9", + "dbRef": "\"DB_JamArea5002\".stJam5002_9", + "from": "TRO527", + "kind": "dir2" + } + ], + "exits": [ + { + "jamArea": "JA5002_10", + "dbRef": "\"DB_JamArea5002\".stJam5002_10", + "to": "TRO529", + "kind": "normal" + } + ] + }, + { + "id": "TRO529", + "fbType": "1Sep", + "comment": "TRO 529 (1Sep) + Scanner (BX5113)", + "entries": [ + { + "jamArea": "JA5002_10", + "dbRef": "\"DB_JamArea5002\".stJam5002_10", + "from": "TRO528", + "kind": "normal" + } + ], + "exits": [ + { + "jamArea": "JA5002_1", + "dbRef": "\"DB_JamArea5002\".stJam5002_1", + "to": "TRO504", + "kind": "normal" + } + ] + }, + { + "id": "TRO530", + "fbType": "Vario", + "comment": "TRO 530 (Vario)", + "entries": [ + { + "jamArea": "JA5001_2", + "dbRef": "\"DB_JamArea5001\".stJam5001_2", + "from": "TRO500", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA5001_3", + "dbRef": "\"DB_JamArea5001\".stJam5001_3", + "to": "TRO501", + "kind": "finger" + } + ] + }, + { + "id": "TRO531", + "fbType": "Vario", + "comment": "TRO 531 (Vario)", + "entries": [ + { + "jamArea": "JA5000_2", + "dbRef": "\"DB_JamArea5000\".stJam5000_2", + "from": "TRO502", + "kind": "finger" + } + ], + "exits": [ + { + "jamArea": "JA5000_3", + "dbRef": "\"DB_JamArea5000\".stJam5000_3", + "to": "TRO503", + "kind": "finger" + } + ] + } + ], + "connections": [ + { + "from": "TRO502", + "to": "TRO531", + "jamArea": "JA5000_2", + "kind": "finger", + "dbRef": "\"DB_JamArea5000\".stJam5000_2" + }, + { + "from": "TRO531", + "to": "TRO503", + "jamArea": "JA5000_3", + "kind": "finger", + "dbRef": "\"DB_JamArea5000\".stJam5000_3" + }, + { + "from": "TRO500", + "to": "TRO530", + "jamArea": "JA5001_2", + "kind": "finger", + "dbRef": "\"DB_JamArea5001\".stJam5001_2" + }, + { + "from": "TRO530", + "to": "TRO501", + "jamArea": "JA5001_3", + "kind": "finger", + "dbRef": "\"DB_JamArea5001\".stJam5001_3" + }, + { + "from": "TRO501", + "to": "TRO504", + "jamArea": "JA5002_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_1" + }, + { + "from": "TRO503", + "to": "TRO504", + "jamArea": "JA5002_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_1" + }, + { + "from": "TRO529", + "to": "TRO504", + "jamArea": "JA5002_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_1" + }, + { + "from": "TRO528", + "to": "TRO529", + "jamArea": "JA5002_10", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_10" + }, + { + "from": "TRO504", + "to": "TRO505", + "jamArea": "JA5002_2", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_2" + }, + { + "from": "TRO505", + "to": "TRO510", + "jamArea": "JA5002_3", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_3" + }, + { + "from": "TRO509", + "to": "TRO510", + "jamArea": "JA5002_3", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_3" + }, + { + "from": "TRO510", + "to": "TRO514", + "jamArea": "JA5002_4", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_4" + }, + { + "from": "TRO513", + "to": "TRO514", + "jamArea": "JA5002_4", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_4" + }, + { + "from": "TRO514", + "to": "TRO518", + "jamArea": "JA5002_5", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_5" + }, + { + "from": "TRO517", + "to": "TRO518", + "jamArea": "JA5002_5", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_5" + }, + { + "from": "TRO518", + "to": "TRO522", + "jamArea": "JA5002_6", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_6" + }, + { + "from": "TRO521", + "to": "TRO522", + "jamArea": "JA5002_6", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_6" + }, + { + "from": "TRO522", + "to": "TRO526", + "jamArea": "JA5002_7", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_7" + }, + { + "from": "TRO525", + "to": "TRO526", + "jamArea": "JA5002_7", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_7" + }, + { + "from": "TRO526", + "to": "TRO527", + "jamArea": "JA5002_8", + "kind": "normal", + "dbRef": "\"DB_JamArea5002\".stJam5002_8" + }, + { + "from": "TRO527", + "to": "TRO528", + "jamArea": "JA5002_9", + "kind": "dir2", + "dbRef": "\"DB_JamArea5002\".stJam5002_9" + }, + { + "from": "TRO505", + "to": "TRO506", + "jamArea": "JA5003_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5003\".stJam5003_1" + }, + { + "from": "TRO506", + "to": "TRO507", + "jamArea": "JA5003_2", + "kind": "finger", + "dbRef": "\"DB_JamArea5003\".stJam5003_2" + }, + { + "from": "TRO507", + "to": "TRO508", + "jamArea": "JA5004_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5004\".stJam5004_1" + }, + { + "from": "TRO510", + "to": "TRO511", + "jamArea": "JA5005_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5005\".stJam5005_1" + }, + { + "from": "TRO511", + "to": "TRO512", + "jamArea": "JA5005_2", + "kind": "normal", + "dbRef": "\"DB_JamArea5005\".stJam5005_2" + }, + { + "from": "TRO514", + "to": "TRO515", + "jamArea": "JA5006_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5006\".stJam5006_1" + }, + { + "from": "TRO515", + "to": "TRO516", + "jamArea": "JA5006_2", + "kind": "normal", + "dbRef": "\"DB_JamArea5006\".stJam5006_2" + }, + { + "from": "TRO518", + "to": "TRO519", + "jamArea": "JA5007_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5007\".stJam5007_1" + }, + { + "from": "TRO519", + "to": "TRO520", + "jamArea": "JA5007_2", + "kind": "normal", + "dbRef": "\"DB_JamArea5007\".stJam5007_2" + }, + { + "from": "TRO522", + "to": "TRO523", + "jamArea": "JA5008_1", + "kind": "normal", + "dbRef": "\"DB_JamArea5008\".stJam5008_1" + }, + { + "from": "TRO523", + "to": "TRO524", + "jamArea": "JA5008_2", + "kind": "normal", + "dbRef": "\"DB_JamArea5008\".stJam5008_2" + } + ], + "externals": [ + { + "node": "TRO502", + "direction": "in", + "jamArea": "JA5000_1", + "dbRef": "\"DB_JamArea5000\".stJam5000_1" + }, + { + "node": "TRO500", + "direction": "in", + "jamArea": "JA5001_1", + "dbRef": "\"DB_JamArea5001\".stJam5001_1" + }, + { + "node": "TRO508", + "direction": "out", + "jamArea": "JA5004_2", + "dbRef": "\"DB_JamArea5004\".stJam5004_2" + }, + { + "node": "TRO512", + "direction": "out", + "jamArea": "JA5005_3", + "dbRef": "\"DB_JamArea5005\".stJam5005_3" + }, + { + "node": "TRO516", + "direction": "out", + "jamArea": "JA5006_3", + "dbRef": "\"DB_JamArea5006\".stJam5006_3" + }, + { + "node": "TRO520", + "direction": "out", + "jamArea": "JA5007_3", + "dbRef": "\"DB_JamArea5007\".stJam5007_3" + }, + { + "node": "TRO524", + "direction": "out", + "jamArea": "JA5008_3", + "dbRef": "\"DB_JamArea5008\".stJam5008_3" + } + ] + } +} \ No newline at end of file